Loading...
HomeMy WebLinkAboutPermit D01-277 - BOEING #7-34 - MAINTENANCE PLATFORMS001-277 Boeing #7 -34 2779 Gateway Dr City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: 271600 -0060 Permit No: 001 -277 Address: 12779 GATEWAY DR Status: ISSUED Suite No: Issued: 09/18/2001 Location: Expires: 03/17/2002 Category: AOFF Type: DEVPERM Zoning: M1 Const Type: Occupancy: INDUSTRIAL PLAN. Gas /Elec.: UBC: 1997 Units: 001 Fire Protection: SPRINKLERS Setbacks: North: .0 South: .0 East: .0 West: .0 Water: 125 Sewer: TUKWILA Wetlands: Scopes: N Streams: Contractor License No: BOEINC*294ML OCCUPANT BOEING #7 -34 • Phone: 12779 GATEWAY DR, TUKWILA, WA 98168 OWNER ; .KAISER GATEWAY ASSOC 12870 : INTERURBAN AVE S, SEATTLE WA 98168 CONTACT JOHN MURDOCH Phone: 253- 773 -0444 PO BOX 3999, M/C 89 -15, SEATTLE, WA 98124 CONTRACTOR BOEING COMPANY PO, BOX 3707, M/S IF -09, SEATTLE, WA 98124 **• k***• k• k* k. *..** • k****************************** k**k k*• k* * ** *k * ******k * * ***** *k* * * *** *•k Permit Description: CONSTRUCT MAINTENANCE PLATFORMS FOR ACCESS TO MAIN TANCE HVAC EQUIPMENT. *******• k*************** k****************************** * * * * ** *** ** * * **** *•* * * * * * * * *•k' Construction 'Valuation: • $ DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. 7,500.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No Size(in) : .00 Flood Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main, Extension: N Private: N Public: N * * * * ** k **•k* *•k * * * ** * * ***** * ** k•k * * * *** *•k k * *•k k k•k k k k*** ***** k k ** k k * * * * * ** * *•k **** ** TOTAL DEVELOPMENT PERMIT FEES: $ 257.36 * * ** * * * * * ** k * * * * *k k * * ** k * ** ** * * *k * *k **** k * * * ** *** ** * * *•k * * ** **** k * * * * * * * * k Signature:__ Permit. Center Authorized Signature:, ot -e"! (206) 431 -3670 Date: l' I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. — _ Date: 1__L e =Q/ Print N ame: ___ILZ!Z ___ __ 0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 1 CITY OF TUKWILA • Address: 12779 GATEWAY DR Permit No: 001-277 Suite: , Tenant: Status: ISSUED Type: DEVPERM Applied: 08/29/2001 Parcel #: 271600-0060 Issued: 09/18/2001 ***********k********************* PerMit Conditions: 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2. .When special inspection is required either the owner, 'architect or engineer shall notify the Tukwila Building .Division of appo•4tment of the inspection agencies prior to the first bupding inspection. Copies of all special inspection reports shall be submitted to the Building C.livisiolvin a timiely manner. , Reports shall contain address, )roject number and type of inspection being performed. . The • special inspector shall subiiitt a final signed report staOng whether the worki'requiring special inspection was, to4the best of the inspector's knowledge, in conformance wiihapProvedlansand specifications and the applicable workmanship provisions of the UBC. M1 construction to . ,be 'done in conformance with approved •1,3this and requirenientsof the UnAforM'Building Code . (1997 .- cA4tion),,as,7amended, UniforM Mechanical Code (1997 Edition),' atf Washington ' State ,Energy Code (1,997 Edition). Vaiidity issuance' of - a permit or approval of Oans;''Specificatiopk, and 'computations shall not be con'- ktrued'to be a permit for, or an approval of, any violation Ofany ofo,the provisions of the 'building code or of any , other ordinance of the jurisdiction.. No permit presumin•:to giVe% authority to violate or cancel the provisions of this cotle shall ,be valid. . ,Electrical permits shall be obtained through the Washington State';Division of Labor and Industries and all electrical' work ill be inspected by that agency (248-6530)_, All permits, inspection records, and approved Plans shall be available ;,at the job site prtor,to the start of any structi64-These documents are to be maintained and avail- able untifjinal inspection approval is granted.• . A11 structural,,:Welding shall , be done by certified welders and special inspected (Mk Sec. 306(a)5). I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to .. violate or cancel the provisions of any other work or local laws regulating construction or the performance of work. ignature: /2/e//n40 1) . Date: • r ; ;..- e Project Name /Tenant: 3 '.. /4, aht p m Value of &e c�'St V Site Acid s�('t e ss� rti l w p City State /Zip: Ta yc t : , r aild . Property Owner: ONeo � Ph( c: (c ) al (1 3 V Fax II: Street Address: / ty� lZ' t t. I Contractor: Phone: Street Address: City State /Zip: Fax !1: Architect: MI VL 5 1 (4 / , Phonj�,��5 si 14609. StreetAd6e:ssx 3g57. N . lip► 1(fl/' Fax #: Engineer: q8a 1.l Phone: Street Address: City State /Zip: Fax 11: Contact Person`ib s unmet - Ph 53) 1- ?,3- W4/ F ir s5) 3 f Re3 P I4 � Dq'I5 ,W rig Witty WO Description of work to be done (please be s )ecific): j ,� r =^ � - n �f� Coxisrocr % 44 W Atre 6 sS To Migin Mid f-1 If Existing use: ❑ Retail ❑ Restaurant , El Multi - famil El Warehouse ❑ Hospital ❑ Church ❑ Manufacturing L 1 Motel /Hotel Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail 11 Restaurant ❑ Multi - famil ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel iZi Office ❑ School/College/University ❑ Other th� __ ____ __ _ _ J 1 Area of construction (sq ft): 0 Building Square Feet: !at existing No. of Stories: c� ' Will there be a change of use? ❑ yes no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 21 no Existing fire protection features: RI sprinklers ❑ au omatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable /combustible hazardous material in the building? 54 yes ❑ no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Shee s ^ ,, APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault)lt: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Project Number: Commercial / Multi - Family Tenant Improvement / Alteration Permit Application CITY OF TUK ILA Permit Center 6300 Southeenter Blvd., Suite 100 Tukwila, WA 98188 1 1 Sill (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Value of Construction - In all cases, a value of construction amount should be entered by the applicant.. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 11 /30 /lll) clpenni(d c • y /oi Date application expires: ,it///oa PLEASE SIGN BACK OF APPLICATION FORM, , uw,!uM�e!E.hbarsYF Application taken by: (initials) 1 BUILDING OWNER OR AUTHORIZED AGENT: Signature: • Date: Print name: Phone: Fax it: Address City /State /Zip APPLICATIOOMUST BE SUBMITTED WITH THE ' LLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL EN9,14f414,0R cIALINGINEER • ALL" DRAVCIING SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED in ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Fortn H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20 %, or greater, wetlands, watercourses and their buffers (change of use only) sensitive. area Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if.in flood control zone) • 13. See Public Works Checklist, for detailed civil /site plan information required for Public Works Review (Form H -9). Z ~ W tY c S O 0 CO CI CO U.1 J = ❑ 71 Floor plan: show location of tenant space with proposed use of each room labeled -J 1- w ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of 2 any hazardous materials; dimensions of proposed tenant space. 5 Li. Q ❑ ❑ Vicinity Map showing location of site = 0 I-w ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack Z H layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of Z O rack. Structural calculations are required for rack storage eight feet and over. W ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished U ❑ ❑ Construction details 0 D ill w ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water 1-- H supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed - O sprinkler system design criteria as identified by the Fire Department. lit U ❑ ❑ Washington State Non-Residential E Code Data shall be noted the entianergy oe ata sae note on te construction drawings. ~ I— ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent lithe applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11/30/00 ciperuiii.duc �� i.. :x;.G.l4 ��'n1.'�6:J75 it`t�i- ..i:l•14%.i� Z ** * *I` * * * * :1444 *` *; *,t * * *' ** * * * * * * * * * * * * *4 *' ** * * *: Repi ^ii7ted:: 0'8 /2q /01 15«5 TRAwsMIT *. *+ * : ;fir * *` * "C* *4 *, i * 4 ** 4'* * * * * * *. * ** *fir * * ** 5 * *A. * * * * * *a *4' * * * * * *'* i RA0,0411 Wumbnr» RQ101123 257 '08/29/01 ,15:4f R' zvme.nt hiethott CHECK: Notation. SHARED SERV CES. In it: KAS er`mi ::110 D(}1=.277 ' ':. Type: DEVPERM DEVELCEPMENT : :PE-RAfIT`: P a`r7cel. Ng : : 271$ 907.0,060 i0 Ad.dr ess ::.1.2x79 OA I.EWAY DR . .. T ot . .c� 1 Fees; 1 M3G 1.1s-; `PaneMt .,! »Sc� Tcaiiicl l L : Paat.�o 257.36 17 al once . .00 ***,t ;!' * * * * '** k*.****: 4*******. t** A***A *d: **k * * **.ii': * * * * **+ iv * * * * A. ctcufti; Code ".: Desrr lilt ion Amour 060'/322.;;, . Buli..t)TPG —' NONRES t53..25 v � * a / a � anC � a `> PLAN CHtrG r1 ic - O1�it 5 99.61 V,VV /'386..9 { � 2 4.': STATE: BUI.L. SURCHARGE 4.50..:: • INSPECTION RECORD Retain a copy with permit mrtciloN NO. ITY DIVISION 300.SOUthceriter Blvd; #100, Tukwila, WA 98188 101- c?-i PERMIT NO. , Address:. C;c1 -Spec instructions: vv. t — Type of Inspection: C Ci Date called: I I" Date wanted: a.m p.m. Requester: ct Phone: Approved per applicable codes. Corrections required prior to approval. .COMMENTS: vyi 1 •1 - 4-1 - er l e' s 1 se-6 ( 1 v(A) ; &)\ ■ 0 r lorr) i' (206)431-3670 Insbectq Date: 1, ko $47.06 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at,6300-SOuthcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: . , . 1 - 0.k ! • — , .• fzb • $ ,0 z .. • Project: loetl - 7- 3 Li Type of lnspectio v. , Address: Date called: Special instructions: Date wanted: Requester: . Phone: 2_06 - 2.. 2- q$16 • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 • "" • 'r;•V''' INSPECTION RECORD Retain a cry with permit PERMIT NO. 70 Approved per applicable codes. ri Corrections required prior to approval. COMMENTS: Pirvi Cr) L4 Inspector. Date: 0 2, $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 1. • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 i i i (t 4 i; INSPECTION RECORD Retain a copy with permit ddres • Ty • = of Inspection: Date called: Requester: one: PERMIT NO. (206)431 -3670 Approved per applica le codes. t4 Corrections required prior to approval.: COMMENTS: } i v\e, t k1rw Y u(40-1/ N1 1 h Pp r G ' Y) V[3t & v\ V�! in P_ - vr)vh ' d :et ( (0 o-' 56 t1Y S lnv■r,,A-4 y cry ler C AG1‘' 1h SDP4OJ"S Irc • 3) £ Ovr i C 0 cA O f L4eet'" 'C) r'1n. sso J rlu4d 1 1- 8 -ot Inspector:"` Date: 1,. 0 z $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • • ect: _AI '', ri 46 All Ty le of Inspect'o 'Ilia Cl- RiiiiiWAMIMIUS Ad • ress: 1,211 6� J rc -Eec Date called: i 0/ i l o? i nstructions: Special r Lk) i 1 Date w me : a 1 i Re er: Phone: G' �JSf?i; `Je L.vh:lt. iC�P:• 4.. ✓.:{xS.'wNS''�S• >ilz ?{'<tii 1L2:�4Y'�;:i:ErwY:'6 Ft� ll':ki fy.laxk.t:.' . INSPECTION NO. E1 Approved per applicable codes. Inspector:- / : ;t11 f. iIj: 4 err r. INSPECTION RECORD Retain a copy with permit PERMIT NO: CITY OF TUKWILA BUILDING DIVISION Fy'q tM t 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ( � (206)431 -3670 COMMENTS: -Por 5 <' r ( c • t vv. 2 c 10 refclt r cie ue 014;1S , if` eci th r rti U Y C' �n 03r•i-r 114 , r, eon c ter e Cl-1Q -C via 1 I e-kArr Trnm 4 we- 1 r `Frts Corrections required prior to approval. Date: 11— ) _ 0 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: � w..S •'+.Y�JJ✓�}}a'r : 27.. -):i: � �i�.1� ,I� iAlr�~ y ; :�1.'Y. y',�i.J I):..4��...�i+. �. \. . � �.�f ✓n'�.6N't5i �0..;!ri.!RU'3Y. _.il.. �.� S: MAYES TESTING ENGINEERS, INC. January 10, 2002 City of Tukwila Building Division 6300 Southcenter Boulevard Tukwila, WA 98188 -2545 Attn.: BiII Rambo Re: Gentlemen: MSD:Iak RECEIVED JAN 15 2002 COMMUNITY DEVELOPMENT Boeing Renton Bldg. 7 -34 Platforms Tukwila, WA MTE Project No. E2003 This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent you. To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. Special inspection was provided for: 1) Structural steel welding — platform 2) Epoxy Grouted Anchor Bolts Sincerely, MAYES TESTI , G ENGINEERS, INC. /e6,Fv,c HS. D. chael S older, P.E. ce President CC: Ed Castilo — Ed Castilo Construction Jack Andrew - Boeing FINAL LETTER Permit . #D01 - Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 We trust that this provides you with the information which you require. Should you have any questions give us a call. JOB NUMBER: E /2- ? Z DATE: / - B - 0 2- gaF /A-er 6 PROJECT: fir., Se. Al a .. f,_...Ap gz- )e-- I -7y a .1 .. i o .. $ 7—,4.v 4 .... PERMIT #: O /- 2 "7 ` . WEATHER: C L ° w } OWNER: g2 A f c.,- ARCHITECT: ENGINEER: � � � F � t / CONTRACTOR: e 4 f 7 7 4 - < .n TYPE OF INSPECTION: , p +, ;-• / 4 9 /r , - J SAMPLES: ti 1 .. Z MAYES IM MO ENGINEERS, ..dC. 917 -134th St. SW, Suite A -1 Everett, WA 98204 10029 S. Tacoma Way, Suite E -2 Tacoma, WA 98499 7911 NE 33rd Drive, Suite 190 Portland, OR 97211 INSPECTOR: 7 • ,A c c SUMMARY: S Ir , 4 / ti &/s C G / p STn. / �J Ph 425.742.9360 Fax 425.745.1737 Ph 253.584.3720 Fax 253.584.3707 Ph 503.281.7515 Fax 503.281.7579 4-) HRS. INSPECTOR: HRS: INSPECTOR: HRS SITE TIME: TO: +9 F 7 9 o,•� ( /-4/.. j/ / - / S ) f r f VTo'the best of our knowledge; item inspected thii'date are in accordance with approved plans and ecificatidr s : :.:.. Yes: No E Preliminary Inspection O / ,--' I j A L c 4 .-ZJ J A f J. 1 -a ? —OZ : f !-.y NONCONFORMING CONDITIONS /CORRECTIVE ACTION TAKEN: .�i Page / of / t NS O / Y a- '9 .1 � L L 7 A. It / / -4 v r -t c � O a -1 A / L ..X e .0 h z 7 ")I r 1,4 r / l i f' / / r e , .0 , ,- -Q i1'" C: LL `t: ^�":S°SG.S9Mk.YC.Y.Y�'_17: PAM+ u}r ^. wY' k+ tkt fa:vrtliJ�U•tYSr.tSRflKEiQWN,Y.? W'j{b( /(,H., `���eC•; ^,,yT MAYES TESTING ENGINEERS, INC. January 4, 2002 City of Tukwila Building Division 6300 Southcenter Boulevard Tukwila, WA 98188 -2545 Attn.: Bill Rambo Re: Boeing Renton Bldg. 7 -34 Platforms Tukwila, WA MTE Project No. E2003 Gentlemen: This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent you. To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. Special inspection was provided for: 1) Structural steel welding - platform We trust that this provides you with the information which you require. Should you have any questions give us a call. Sincerely, MAYES TEST___ " GIN INC. Michael S. Dolder, P.E. Vice President MSD:Iak CC: Ed Castilo — Ed Castilo Construction Jack Andrew - Boeing RECEIVED JAN 0 8 2002 COMMUNITY DEVELOPMENT FINAL LETTER Perm lt:# 130'1 = Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 ACTIVITY NUMBER: D01 - 277 DATE: 8 -29 -01 PROJECT NAME: Boeing 7 -34 Maintenance Platforms SITE ADDRESS: 12779 Gateway Dr. SUITE # X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter# Revision # After Permit Is Issued DEPARTMENTS: Building Division mac- f aD.ot Public Works dOtah NA. Lto • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 PERMT COORD COPY PLAN REVIEW /ROUTING SLIP f71�' Fire Prevention M' R -c.-o1 Structural Incomplete Structural Review Required APPROVALS OR CORRECTIONS: (4 weeks) REVIEWER'S INITIALS: REVIEWER'S INITIALS: Plannin g bivision Permit Coordinator DUE DATE: 8-30 -01 Not Applicable No further Review Required DUE DATE 9 -27 -01 Approved n Approved with Conditions n Not Approved (attach comments) b�- n REVIEWER'S INITIALS: DATE: DATE: DUE DATE Approved with Conditions n Not Approved (attach comments) DATE: �.... ay. rnvmc�w�'+ 4nM`+ MM*�lM: »fi<Yrttwlw6�aM.".l�+k]Mt fe*VXMISIK KW.Wor..A1N C4n4V, kfl41J9N�YNDt�N ACTIVITY NUMBER: D01 -277 DATE: 8 -29 -01 PROJECT NAME: Boeing 7 -34 Maintenance Platforms SITE ADDRESS: 12779 Gateway Dr. SUITE # r c Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Complete TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Approved \PRROUTE.DOC 5/99 n n REVIEWER'S INITIALS: CORRECTION DETERMINATION: REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required APPROVALS OR CORRECTIONS: (4 weeks) Approved wit Conditions Planning Division n Permit Coordinator DUE DATE: 8-30-01 Not Applicable Comments: n No further Review Required DATE: DUE DATE 9 -27 -01 Not Approved (attac comm nts) DATE: Approved Approved with Conditions n Not Approved (attach comments) DUE DATE DATE: ANA PERMITNO.: Vo`v 2 T7 BUrLIIING } 't ERiYRTS INSPECTIONS ❑ 00001 Progress Inspection Status ❑ 00002 Pre - construction ❑ 00003 Investigation ❑ 00004 OK to Occupy ❑ 00005 Remove Stop Work Order ❑ 00006 Follow -up ❑ 00007 Pre -Move Inspection ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Tndoor AQC ❑ 00070 NLEA Inspection/Ivlpdular Struct ❑ 00071 Mobile Home Tie Down Insp ❑ 00072 Marriage Lines ❑ 00090 Rested ❑ 00095 Footing Drains ❑ 00100 Foundation Footings ❑ 00200 Foundation Walls ❑ 00250 Foundation Insulation ❑ 00300 Concrete Slab /Slab Insulation ❑ 00350 Crawl Space ❑ 00400 , Shear Wall Nailing ❑ 00450 Plywood Wall Sheathing ❑ 00500 Roof Sheathing Nailing ❑ 00525 Plywood Deck Nailing ❑ 00550 Exterior Wall Sheathing ❑ 00600 Masonry Chimney ❑ ,00610 Chimney Installation /AII Types 0700 Framing 00750 Roof /Ceiling Insulation ❑ 00800 Floor Insulation ❑ 00801 Wall Insulation ❑ 00802 Exterior Roof Insulation ❑ 00803 Glazing Inspection ❑ 00815 Lighting and Controls ❑ 00900 Suspended Ceiling ❑ 01000 Interior Wallboard Fastening ❑ 01001 Exterior Wallboard Fastening ❑ 01 1 10 Pre -Move Inspection ❑ 01 1 15 Motor Inspection ❑ 01120 Pre -Demo ❑ 01140 Pre- reroof 0 ,01400 Final -Fire 01700 Final - Building ❑ 01900 Final- Reroof • ❑ 03100 Site Visit ❑ 04000 Special- Concrete ❑ 04001 Special -Bolts in Concrete ❑ 04001 Special-Mom/Resist Conc Frame ❑ 4003 Special -Reinf Steel Prestress 04004 Special - Welding ❑ '4005 Special- High - Strength Bolting ❑ 04006 Special- Structural Masonry ❑ 04007 Special-Rein( Gypsum Concrete ❑ 04008 Special- Insulating Conc Fill ❑ 04009 Special -Spray Fireproofing ❑ 04010 Special- Piling, Piers, Caissons ❑ 04011 Special- Shotcrete ❑ 0401 Special- Grading, Excav/Fill ❑ 04013 Special- Retaining Wall ❑ 04014 Special- Panels ❑ 04015 Special -Smoke Control System TENANT NAME: / ✓ 1 CONDITIONS Plan Reviewer: Permit Tech: ' NaiCOrnb 0001 No changes to plans unless approved by Bldg Div 0010 Special inspection required, notify Bldg Div 001 1 Special inspector shall submit final signed report ❑ 0012 New ceiling grid & light fixture shall meet lateral bracing ❑ 0013 Partition walls attached to ceiling grid ❑ 0014 Readily accessible access to roof mounted equipment ❑ 0015 Engineered truss drawings & calcs shall be on site ❑ 0016 Exposed insulation backing material ❑ 0017 Subgrade preparation including drainage, excavation ❑ 0018 Statement from roofing contractor verifying fire retardant class of roof 0019 All construction to be done in conformance w /approved plans ❑ "No work shall be done in addition to those modifications..." ❑ 0002 Plumbing permits shall be obtained through King Co ❑ 0020 Structural observation shall be provided for this project ❑ 0021 All food preparation establishments must have King Co ❑ 0023 Fire retardant treated wood shall have flame spread of ❑ 0023 Notify Building Division prior to placing any concrete ❑ 0024 All spray applied fireproofing shall be special inspected ❑ 0025 All wood to remain in placed concrete shall be treated CA / 0026 All structural masonry shall be special inspected 0027 Validity of Permit ) ni l 0028 Rack storage requires separate permit 0003 Electrical permits obtained through L & 1 ❑ 0030 No occupancy of building until final insp by Bldg Div ❑ 0032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0035 Contact PW Div to obtain insp for water /sewer connect ❑ 0038 A C of 0 will be required for this permit ❑ 0039 Final approval for all 1'I w /in the limits of the SC Mall ❑ 0004 All mechanical work shall be under separate permit ❑ 0040 All construction noise to be in compliance with 8.2 TMC ❑ 0041 Ventilation is required for all new rooms & spaces X 0005 All permits, insp records & approved plans available 0006 All structural concrete shall be special inspected ❑ "Applicant shall obtain a separate plumbing permit from King Co" ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" 0007 All structural welding shall be done by WA130 certified inspector ❑ 0008 All high- strength bolting shall be special inspected ❑ 0009 Bolts installed in concrete shall be special inspected ❑ 0031 Comply with requirements of TMC 16.04 ❑ 0034 Removal aseptic tanks require approval and compliance with King Co Health Dept. ❑ "Obtain required inspections from appropriate water & sewer districts" ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...." ❑ "Reroot" Date: Date: • DEPARTMENTS: Building Division Public Works Complete Approved \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D01 -277 DATE: 8 -29 -01 PROJECT. NAME: Boeing 7 -34 Maintenance Platforms SITE ADDRESS: 12779 Gateway Dr. SUITE # X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: Approved Tel Approved with Conditions CORRECTION DETERMINATION: REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 8-30-01 Not Applicable Comments: No further Review Required DATE: P- 6 —b( APPROVALS OR CORRECTIONS: (4 weeks) DUE DATE 9 -27 -01 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: 9 "o/ Approved with Conditions ri Not Approved (attach comments) DUE DATE DATE: ACTIVITY NUMBER: D01 - 277 DATE: 8 -29 -01 PROJECT NAME: Boeing 7 - 34 Maintenance Platforms SITE ADDRESS: 12779 Gateway Dr. SUITE # \ Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROUTING: Please Route ri Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (4 weeks) Approved Approved \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP n n Approved with Conditions CORRECTION DETERMINATION: Fire Prevention Structural Incomplete n REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 8-30-01 Not Applicable Comments: No further Review Required DATE: DUE DATE 9-27 -01 Not Approved (attach comments) DATE: DUE DATE Approved with Conditions U Not Approved (attach comments) REVIEWER'S INITIALS: DATE: ACTIVITY NUMBER: D01 -277 DATE: 8 -29 -01 PROJECT NAME: Boeing 7 -34 Maintenance Platforms SITE ADDRESS: 12779 Gateway Dr. SUITE # Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works PLAN REVIEW /ROUTING SLIP n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ri Incomplete TUES /THURS ROUTING: Please Route ri Structural Review Required REVIEWER'S INITIALS: ) .5 APPROVALS OR CORRECTIONS: (4 weeks) Approved Approved with Conditions CORRECTION DETERMINATION: Approved I I Approved with Conditions REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 Fire Prevention Structural 1 DUE DATE: 8-30-01 Comments: REVIEWER'S INITIALS: No further Review Required IX DATE: Planning Division Permit Coordinator Not Applicable DUE DATE 9 -27 -01 Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: Ri 4 4, 0. 4'41 ;;4i f'ih.'�'c�uJ>aUs�'vli6A.�:; Revision • No. Date Received Staff 1 Initials { Date Staff Issued Initials Date Issued ' • 1 - Staff Initials Received By: • Received By: Summary of Revision: Z , , --7'..€ v- ..-`� Received By: \robree. AdViehtfdeW Revision No. Date 1 Received Staff Initials Date Staff Issued Initials I � Summary of Revision: Received By: • Received By: Revision No. 7 Date + Received Staff I Initials Date Issued Staff Initials Summary of Revision: Received By: Revision No. Date Received Staff Initials Date Issued Staff Initials Summary of Revision: Received By: Revision No. Date Received Staff Date Staff Initials Issued Initials T , Summary of Revision: Received By: . PROJECT NAME: .d .~' 7 �� Site Address: 4, 7 € REVISION LOG PERM1 I" NO:. /id / -- c 2 77 Original Issue Date: e ,tite.07 (please print) ' (please print) (please print) (please print) z w O 0 CO 0 J = • LL w O u_ < CO d = w Z �. I-0 Z F- UJI :0 • N' 0 — w • uj F- .. co h 0 z Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: MAN 265Z City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431-3670 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued Project Name: CoA 1 2 1 - g 9 Gitre pe► fib. 7-34 Project Address: Contact Person: Zr .5- MORPOCI J Summary of Revision: Entered in Sierra on Plan Check/Permit Number: PD 1-A9t-7 Phone Number: 67 3) 4-73 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: RECEIVED CITY OF TUKWILA JAN 0 8 2002 08/30/00 PERMIT CENTER .. °_..,.ors +, s.: ; . wwr« Wit;, r z •,:., , W 6 ✓ O J = H uJ O = • Cl _ : z � Z • o U �' 0 ST w W ; X U' — ui z. z SYM A REVISIONS VICINITY MAP PUGET SOUND REGION SITE MAP TO TACOMA RENTON PIERCE CO. BUILDING 7 -34 PROJECT SITE NO SCALE 0 NO SCALE RELOCATE VAULTS - PHASE 2 RELOCATE RADIO SERVICES REVISION BY RBB RBB RBB APPROVED GATEWAY CORPORATE CENTER CONSTRUCT MAINTENANCE PLATFORMS BUILDING 7 -34 12779 GATEWAY DRIVE TUKWILA, WA 98188 MJS MJS MJS DATE 07/31/00 08/25/00 09/01/00 SYM REVISION APPROVED LEGAL DESCRIPTION: PARCEL A: PARCEL B: A NON- EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS IN AND ACROSS THE FOLLOWING DESCRIBED PROPERTY: ZLAinsmsrAfie. ALL THAT PORTION OF THE CYRUS C. LEWIS DONATION CLAIM NO. 37, LYING IN SECTIONS 10 AND 15, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE NORTHEASTERLY MARGIN OF THE PUGET SOUND POWER AND LIGHT COMPANY RIGHT OF WAY, SAID POINT BEING NORTH 2720'26" WEST FROM THE QUARTER CORNER BETWEEN SECTIONS 14 AND 15, AT A DISTANCE OF 1,722.57 FEET BASED ON THE NORTH ZONE LAMBERT GRID SYSTEM FOR THE STATE OF WASHINGTON, SAID POINT BEING ALSO THE SOUTHWEST CORNER OF THAT CERTAIN TRACT OF LAND CONVEYED TO FRANK MENAGLIA AND VITTORIE DEMARCKI, AS RECORDED NO. 2693164; THENCE NORTH 41 °46'16" EAST 179.27 FEET; THENCE NORTH 81 °30'14" WEST 45.00 FEET; THENCE SOUTH 28 °05'42" WEST 159.11 FEET TO THE TRUE POINT OF BEGINNING. A STRIP 'OF LAND, 20.0 FEET IN WIDTH AS MEASURED AT RIGHT ANGLES TO AN LYING SOUTHERLY OF A LINE DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE NORTHEASTERLY MARGIN OF THE PUGET SOUND POWER AND LIGHT CO. RIGHT —OF —WAY, NORTH 2720'26" WEST, FROM THE QUARTER CORNER BETWEEN SECTIONS 14 AND 15, A DISTANCE OF 1,722.57 FEET BASED ON THE NORTH ZONE LAMBERT SYSTEM FOR THE STATE OF WASHINGTON, SAID POINT BEGINNING BEING ALSO THE THE S.W. CORNER OF THAT CERTAIN TRACT OF LAND CONVEYED TO FRANK MENAGLIA AND VITTORIE DEMARCKI AS RECORDED IN VOLUME 1513 OF DEEDS, PAGE 121 RECORDS OF THE AUDITOR OF KING COUNTY, WASHINGTON, UNDER RECORDING NO. 2693164, SEPTEMBER 25, 1931; THENCE NORTH 41 °13'44" WEST ALONG SAID NORTHEASTERLY MARGIN 1,570.27 FEET; THENCE NORTH 41 °46'16" EAST 310.54 FEET; THENCE NORTH 8 °29'46" EAST 20.0 FEET TO THE TRUE POINT OF BEGINNING OF THE ABOVE MENTIONED DESCRIPTION LINE; THENCE ALONG SAID DESCRIPTION LINE, NORTH 81 °30'14" WEST 595.37 FEET TO THE NORTHEASTERLY MARGIN OF THE PUGET SOUND POWER AND LIGHT CO. RIGHT —OF —WAY; TOGETHER WITH A STRIP OF LAND 16.0 FEET IN WIDTH EXTENDING FROM THE MOST WESTERLY CORNER OF THE ABOVE DESCRIBED EASEMENT, NORTHWESTERLY ALONG THE NORTHEASTERLY MARGIN OF THE PUGET SOUND POWER AND LIGHTCO. RIGHT —OF —WAY A DISTANCE OF 190.0 FEET, MORE OR LESS, TO A ROAD CROSSING SAID RIGHT —OF —WAY BEING KNOWN AS 42nd AVENUE SOUTH. EXCEPT ANY PORTION WHICH MAY LIE WITHIN PARCEL A. SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. ACCEPTABILITY [RAM THIS DESIGN ANO /0k J CHECKED SPECIFICATION IS APPROVED NGNttH APPROVED EH DEPT. GATE k HECKED C M JS DA COVER SHEET 11 111 1'■1\1/\ 7 AA CODE SUMMARY: EXISTING CONSTRUCTION: PROJECT DESCRIPTION: LAND USE ZONE: BUILDING CODE: OCCUPANCY GROUP: CONSTRUCTION TYPE: GROSS SQ. FOOTAGE: CONSTRUCT MAINTENANCE PLATFORMS FOR ACCESS TO HVAC EQUIPMENT M1 —(LIGHT INDUSTRIAL) UBC B V N — SPRINKLERED 39,210 S.F. ENERGY CODE COMPLIANCE U THERE ARE NO BUILDING ENVELOPE CHANGES OR USE CHANGES. ❑ THERE ARE BUILDING ENVELOPE CHANGES, PLEASE SEE COMPLIANCE FORMS SUBMITTED WITH PROJECT AND NOTES THROUGHOUT DRAWINGS REAM. TO DESIGN THERMAL PERFORMANCE. O THERE ARE NO MECHANICAL CHANGES TO REVEIW FOR THIS PROJECT. ❑ THERE ARE MECHANICAL CHANGES TO REVIEW FOR THIS PROJECT, PLEASE SEE COMPUANCE FORMS SUBMITTED WITH PROJECT AND NOTES THROUGHOUT DRAWINGS RELATIVE TO EQUIPMENT PERFORMANCE, CONTROLS AND ENERGY USE. ❑ THERE ARE MECHANICAL CHANGES TO THIS PROJECT WHICH WILL BE SUBMITTED FOR REVIEW AT A LATER DATE. ❑ THERE ARE NO ELECTRICAL CHANGES TO REVEIW FOR THIS PROJECT. ❑ THERE ARE ELECTRICAL CHANGES TO REVIEW FOR THIS PROJECT, PLEASE SEE COMPUANCE FORMS SUBMITTED WITH PROJECT AND NOTES THROUGHOUT DRAWINGS RELATIVE TO THE LIGHTING DESIGN AND MOTOR EFFICIENCIES. ❑X THERE ARE ELECTRICAL CHANGES TO THIS PROJECT WHICH WILL BE SUBMITTED FOR REVIEW AT A LATER DATE. SEPARATE PERMI REQUIRED FOR: II'MECHANICAL LIIIELECTRICAL LUMBING GAS PIPING CITY OF TUKWILA BUILDING DIVISION NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR A=PPROVAL OF TUKWILA BUILDING DIVISION. raoTE REVISIONS WILL REQUIRE A NEW PLAN SUeMRTAL MD NAY INCLUDE ADDITIO81 PLAN IEVEW FEE& CURRENT REVISION SHEET _FILE COI✓? I understand than the Plan Check approvals are subject 10 POWs and om185181ts and approval of plans does not authorize the violation of any adopted code or ordinan0A. Receipt of con- tractor's copy c$ approved plane acknowledged. By Date q -/ Permit No �I //vim■ AO WY OF TUIMILA AMMO �jp, 1 1 2001 1�ICo: 0 �v131�3 CITY OF TUKWILA SYMBOL PERMIT CENTER DATE 7/13/01 � 0 -dal _ ,.,..,.............„....\ 0 \ \ r 1 I J o I J' , Al i. 5 r n r T - -, M . IN � e ter LL ffi ____ ' _° N, J J I '�� I i ___ ll r L I Ir 7 1 1 I` I�I�_ T- -_ce II` E-- tre .s�iT�i� ,-_, A r- , I I -- i MI i t �i�i© IL lif A NM r o . 1 ® V * t.i .� — a , -TN 1 SYM A MAINTENANCE PLATFORMS REVISION 718111 BY MJS APPROVED DN DATE 7/13/ SYM REVISION PROVED ZLAralsmia. ACCEPTABILITY THIS DESIGN AND /0R SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED ENGINEER CHECKED Am. SUBTITLE 17 4 ' 2' ED B' a SCALE: 1/4 " =1' -0" PARTIAL PLAN RI 11I nIN[, 7_ D01 -277 LEGEND GENERAL NOTES 1> EXISTING AIR HANDLING EQUIPMENT L EXISTING 4" HOUSEKEEPIING PAD [-> EXISTING 6 3/4" X 25 1/2" GLU —LAM 4 > EXISTING 6 3/4" X 22 1/2" GLU —LAM EXISTING 3 1/8" X 12" GLU —LAM @ 8' -0" O.C. © EXISTING 3 1/8" X 12" GLU —LAM EXISTING 4 X 16 © 8' -0" O.C. => EXISTING 2 X 4 s' 2' -0" O.C. TYPICAL. EXISTING 6 3/4" X 36" GLU —LAM Ff EXISTING EXHAUST E> EXISTING INTAKE CONSTRUCTION NOTES NEW 32" DIA. DUCT THROUGH ROOF. SEE SHEET S160 NEW DUCT NEW EXHAUST FAN S' NEW HEAT RECOVERY COIL NEW FILTER BANK © NEW HEATING COIL N "P1 • E SEE DETAIL 1 ON SHE S500 ® NEW SUPPORT FRAME SEE DETAIL 2 ON SHEET S501 C>.-NEW SUPPORT FRAME SEE DETAIL 3 ON SHEET S501 NEW SUPPORT FRAME SEE D AIL RELOCATE PIPE SEISMIC BRACE TO AVOID INTERFERENCE WITH ACCESS TO PLATFORM. D>. RELOCATE (2) LIGHT FIXTURES TO OPPOSITE SIDE OF STEEL FRAME. SEE ELECTRICAL DRAWINGS. KEY PLAN NO SCALE ` CITY OP TUKW PAN NORTH CURRENT REVISION SHEET JOB N0. S450 PERMIT CENTER SYMBOL 0 HE S500 DIY Cf 1 SEP 1 1 2001 AS NOTED ATE 7/13/01 COMP N0. SYM A REVISIONS REVISION B MAINTENANCE PLATFORMS 718111 C REVISE PLATFORM 718111 10.18.00 7/13/01 11.08.11 S501 S501 REMSION 1� FRAMING PLAN S501 SCALE: 1/2" = 1' -0" BAR GRATING GUARDRAIL & TOEBOARD 3 SIDES 4" PE DIAL BR NOTE: MATCH TOP OF GRATING WITH TOP OF ADJACENT STEEL FRAME APPROX 9' -5" AFF APPROVED 5501 S501 TYP. NOTCH BAR GRATING IN FIELD TO AVOID PIPING. S1601S501 S501 S501 SECTION 1" STEEL GRATING 3/16 V S501 3/16 1 1/2"0 STEEL PIPE RAIL 3/8x4 STEEL TOEBOARD ACCEPTABILITY THIS DESIGN AND /OR SPECIRCATION IS APPROVED APPROVED BY X 7 S501 S501 NOTE: MODIFY RAIL IF NECESSARY TO AVOID PIPING T.O. GRATING F1LE COPY 'VA' 2 S501 S501 1/4" #5/0 COIL CHAIN W/ 1/2" SNAP AND 3/8" EYE BOLT BENT BAR 2 1/2x3/8 9 "L 3" � v l1vC% J SECTION SCALE: 1/2" = 1' -0" 2' -0° CLR SHEET S501 DO1 -277 EXIST'G STEEL FRAME FOR ADDITIONAL INFORMATION SEE S501 3/8 ANCHOR cu m16 PERMIT CENTER 12 S501 S501 11/8/01 5' -3" DIAGONAL BRACE. ADJUST TO FIT MECHANICAL EQUIPMENT FRAMING PLAN SCALE: 1/2" = 1' -0" FRAMING PLAN SCALE: 1/2" = 1' -0" S501 S501 TYP. DETAIL SCALE: 3" = 1 -0" 3/16 TS 2 1/2" x 2 1/2" x 3/16" 6' -7" TUBE FRAME. FOR PLATE SEE DETAIL 6 THIS SHEET. TYPICAL EXCEPT AS NOTED. MECHANICAL EQUIPMENT 5160 60 5 51501 TS 2 1/2" x 2 1/2" x 3/16" TUBE FRAME. S5011S501 11 4" S501 1/4 V 7 1/2" 6" DETAIL AT PLATE SCALE: 3" = 1' -0" DETAIL SCALE: 3" = 1' -0" 6" 2 1/2" x 2 1/2" x 3/16" STEEL TUBE FRAME. STEEL PLATE 1/2" X 7 1/2" X 7 1/2" ASTM A36 ANCHOR PLATE WITH 1/2 "0 X 5 1/2" ASTM A325 THREADED RODS. 4 1/4" EMBEDMENT WITH HIT HY150 INJECTION ADHESIVE EDGE OF SLAB - TYPICAL TS 2 1/2" x 2 1/2" x 3/16" TUBE FRAME. S501 1S501 SET LEG OF LADDER TIGHT TO EDGE OF PAD SIM CHIP GROUT RAMP TO BOLT LEG OF LADDER TO FLOOR. BAR GRATING TS 2 1/2x2 1/2X3/16 TS 3 1/2x2 1/2X3/16 WELDED TO NEW TS 2 1/2 X 2 1/2 FRAMING PLAN SCALE: 1/2" = 1' -0" DETAIL AT PLATE SCALE: 3" = 1' -0" REMOVE EXIST'G PLATFORM AND INSTALL NEW PLATFORM AT LOWER ELEV. REWORK COMPONENTS AS NECESSARY. S501 GUARDRAIL & TOEBOARD 4 SIDES NOTE: TOP OF GRATING SHALL BE APPROX 11' -4" AFF. FRAMEWORK MUST CLEAR EXISTING LIGHTS AND PIPING. 1/4 V FACE OF WALL SIM TLE 3 S160 S501 NOTE CHANGED CLEARANCE THIS PLATE ONLY a 4' -1 3/4"± FRAMING PLAN SCALE: 1/2" = 1' -0" FACE OF WALL NOTES: DESIGN LOADS: MAINTENANCE PLATFORM LOAD = 50 PSF, LIVE LOAD RAILING & SAFETY CHAIN= 200 LB APPLIED IN ANY DIRECTION AT ANY POINT ON THE RAIL FOR PLATE SEE DETAIL 7 THIS SHEET STRUCTURAL SHAPES AND PLATES SHALL BE ASTM A36. STRUCTURAL TUBE SHALL BE ASTM A500 GRADE B. STEEL PIPE SHALL BE ASTM A53 GRADE B. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 USING E70XX ELECTRODES BY AWS CERTIFIED WELDERS. FABRICATION AND ERECTION SHALL COMPLY WITH AISC SPECIFICATIONS. SHOP DRAWINGS FOR ALL STRUCTURAL STEEL WORK SHALL BE REVIEWED BY THE ENGINEER PRIOR TO FABRICATION. STEEL MEMBERS SHALL BE GIVEN ONE COAT OF APPROVED PRIMER. GRATING SHALL BE A WELDED RECTANGULAR DESIGN CONSISTING OF STEEL MAIN BARSS 1 "x3/16" SPACED AT 1 3/16" O.C., CROSS BARS TO BE RESISTANCE WELDED AT RIGHT ANGLES TO BEARING BARS, HEXAGONAL CROSS SECTION, AND SPACED 4" O.C. FILED VERIFY ALL DIMENSIONS PRIOR TO FABRICATION. RI 111 num(_' 7_QA 4 S160 S501