Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D01-334 - VALCO GRAPHICS - BUILDING A
VALCO GRAPHICS BLDG A 480 ANDOVER PK E Value of Construction: Type of Fire Protection: Type of Construction: Public Works Activities: doc: Devperm City of iukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 ' Parcel No.: 2623049093 Address: 480 ANDOVER PK E TUKW Suite No: Tenant: Name: VALCO GRAPHICS, INC - BLDG A Address: 480 ANDOVER PARK EASTTUKWILA, WA, Owner: Name: VALCO GRAPHICS INC Address: 480 ANDOVER PARK E, SEATTLE WA Contact Person: Name: F.H.(HAROLD) WILLIAMS Address: 6010 20TH ST. E., STE 5, FIFE, WA Contractor: Name: WM DICKSON CO Address: 3315 SOUTH PINE STREET, TACOMA, WA Contractor License No: WMDICC *108J7 DESCRIPTION OF WORK: REMOVE EXISTING PARTITION WALL IN WAREHOUSE SPACE $4,000.00 SPRIN KLER/AFA „ Vt. Curb Cut/Access /Sidewalk/CSS: Fire Loop Hydrant: Flood Control Zone: N Hauling: N Land Altering: N Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: Channelization / Striping: DEVELOPMENT PERMIT pp3 Start Time: Private: N Private: N ** Continued Next Page ** 001 -334 Number: 0 Start Time: Volumes: Cut Permit Number: D01 -334 Issue Date: 03/13/2002 Permit Expires On: 09/09/2002 Phone: (206)575 -3500 Phone: 253 - 922 -0774 Phone: 253 472 -4489 Expiration Date: 04/01/2002 Fees Collected: $164.96 iform Building Code Edition: 1997 cupancy per UBC: 0025 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. End Time: Public: N Public: N Printed: 03 -13 -2002 .�>. 1 >..�.:e•1�r.. I:f.si4 r x::ul:rkAk.X4YEUt:i1'iYh`ttkik L'41. Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of thi does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr 1 e performance of work. lam authorized to sign and obtain this devel.pm -nt permit. Signature: Print Name: doc: Devperm City of lukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 AA.) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 5 D01 -334 Date: Date: Printed: 03 -13 -2002 lalance Due: $ Need Current. Contractor Registration Card: Yes Need to Enter Contractor Information in Sierra: o �fr t rn < :•< :::; p ... >so : . ; . t�t � �t .. e .. .r Q �t�< ..:.:..:.:....... 'off 7o2 a— d 7 7 y : �.r,;�j;t,.:l�i.�:l� ��. sDJf�.,' S. it+ . txti��F,'?.".'rH'".•a'f%,'�:aPn it�r:. °vYt �� �4+�i�±�i`S;d3�:�`n �Sn < {ri.:ilif z � W 6 J U O 0 t 0 W , • u W 0 0 } u. d . =W F- Z. F- O . z F-: W U � fn • H w w 1 H .. ✓ w o ~ c • lalance Due: $ Need Current. Contractor Registration Card: Yes Need to Enter Contractor Information in Sierra: o �fr t rn < :•< :::; p ... >so : . ; . t�t � �t .. e .. .r Q �t�< ..:.:..:.:....... 'off 7o2 a— d 7 7 y : �.r,;�j;t,.:l�i.�:l� ��. sDJf�.,' S. it+ . txti��F,'?.".'rH'".•a'f%,'�:aPn it�r:. °vYt �� �4+�i�±�i`S;d3�:�`n �Sn < {ri.:ilif z � W 6 J U O 0 t 0 W , • u W 0 0 } u. d . =W F- Z. F- O . z F-: W U � fn • H w w 1 H .. ✓ w o ~ c ACTIVITY NUMBER: D01 -334 DATE: 10 -11 -01 PROJECT NAME: VALCO GRAPHICS, INC - BLDG A SITE ADDRESS: 480 ANDOVER PARK EAST XX Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is Issued t=17,1134 DEPARTMENTS: Building Division Public Works Complete TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP n • Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required Approved ith Conditions Approved with Conditions REVIEWER'S INITIALS: l i Planning Division Permit Coordinator DUE DATE: 10 -1 6-01 Not Applicable Comments: No further Review Required DATE: DUE DATE 11 -13 -01 Not Approved (attac co ents) DATE: 1 DUE DATE Not Approved (attach comments) I 1 DATE: Cr?'ACLM.C.141141:iW.4.V4 e“simsimtdH 4ticxe,ty, ta'tY. utizig$ ;1 4, 4 0 . k.: ;a042 1. w JU O 0. CO 0' w w O : LL Q = • d 1- w Z 1- 0 W 1 n p w • w. O . ..z w . O F" Z PERMIT NO.: BUILDING PERMITS INSPECTIONS ❑ 00001 Progress Inspection Status ❑ 00002 Pre - construction ❑ 00003 Investigation ❑ 00004 OK to Occupy ❑ 00005 Remove Stop Work Order ❑ 00006 Follow -up ❑ 00007 Pre-Move Inspection ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation /Indoor AQC ❑ 00070 NLEA Inspection /Modular Stnict ❑ 00071 Mobile Home Tic Down Insp ❑ 00072 Marriage Lines ❑ 00090 Rested ❑ 00095 Footing Drains ❑ 00100 Foundation Footings ❑ 00200 Foundation Walls ❑ 00250 Foundation Insulation ❑ 00300 Concrete Slab /Slab Insulation ❑ 00350 Crawl Space ❑ 00400 Shear Wall Nailing ❑ 00450 Plywood Wall Sheathing ❑ 00500 Roof Sheathing Nailing ❑ 00525 Plywood Deck Nailing ❑ 00550 Exterior Wall Sheathing ❑ 00600 Masonry Chimney ❑ 00610 Chimney Installation /All Types ❑ 00700 Framing ❑ 00750 Roof /Ceiling Insulation ❑ 00800 Floor Insulation ❑ 00801 Wall Insulation ❑ 00802 Exterior Roof Insulation ❑ 00803 Glazing Inspection ❑ 00815 Lighting and Controls ❑ 00900 Suspended Ceiling ❑ 01000 Interior Wallboard Fastening ❑ 01001 Exterior Wallboard Fastening ❑ 01110 Pre -Move Inspection 0 ,01 1 15 Motor Inspection 01120 Pre -Demo 01140 Pre- reroof 1400 Final -Fire 01700 Final - Building 01900 Final - Reroof ❑ 03100 Site Visit ❑ 04000 Special - Concrete ❑ 04001 Special -Bolts in Concrete ❑ 04001 Special -Mom /Resist Conc Frame ❑ 04003 Special -Reinf Steel Prestress ❑ 04004 Special - Welding ❑ 04005 Special -High- Strength Bolting ❑ 04006 ' Special- Structural Masonry ❑ 04007 Special -Reinf Gypsum Concrete ❑ 04008 Special - Insulating Cone Fill ❑ 04009 Special -Spray Fireproofing ❑ 04010 Special - Piling, Piers, Caissons ❑ 04011 Special - Shotcrete ❑ 04012 Special - Grading, Excav /Fill ❑ 04013 Special - Retaining Wall ❑ 04014 Special - Panels ❑ 04015 Special -Smoke Control System TENANT NAME: CONDITIONS S I ci5 'A 0001 No changes to plans unless approved by Bldg Div ❑ 0010 Special inspection required, notify Bldg Div ❑ 0011 Special inspector shall submit final signed report ❑ 0012 New ceiling grid & light fixture shall meet lateral bracing ❑ 0013 Partition walls attached to ceiling grid ❑ 0014 Readily accessible access to roof mounted equipment ❑ 0015 Engineered truss drawings & calcs shall be on site ❑ 0016 Exposed insulation backing material ❑ 0017 Subgrade preparation including drainage, excavation ❑ 0018 Statement from roofing contractor verifying fire retardant class of roof Y l 00I9 All construction to be done in conformance ‘v/approved plans "No work shall be clone in addition to those modifications..." ❑ 0002 Plumbing permits shall be obtained through King Co ❑ 0020 Structural observation shall be provided for this project ❑ 0021 All food preparation establishments must have King Co ❑ 0022 Fire retardant treated wood shall have flame spread of ❑ 0023 Notify Building Division prior to placing any concrete ❑ 0024 All spray applied fireproofing shall be special inspected ❑ 0025 All wood to remain in placed concrete shall be treated ❑ 0026 All structural masonry shall be special inspected 0027 Validity of Permit 70 x .0028 Rack storage requires separate permit 0003 Electrical permits obtained through L &I ❑ 0030 No occupancy of building until final insp by Bldg Div ❑ 0032 Remove all weeds, concrete, stone foundations. flat concrete ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0035 Contact PW Div to obtain insp for water /sewer connect ❑ 0033 A C of 0 will be required for this permit ❑ 0039 Final approval for all TI w /in the limits of the SC Mall ❑ 0004 All mechanical work shall be under separate permit ❑ 0040 All construction noise to be in compliance with 8.2 TMC > k,03 041 0005 Ventilation is required for all new rooms & spaces All permits, insp records & approved plans available 0006 All structural concrete shall be special inspected ❑ "Applicant shall obtain a separate plumbing permit from King Co" ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" ❑ 0007 All structural welding shall be done by WABO certified inspector ❑ 0008 All high- strength bolting shall be special inspected ❑ 0009 Bolts installed in concrete shall be special inspected ❑ 0031 Comply with requirements of TMC 16.04 ❑ 0034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ "Obtain required inspections from appropriate water & sewer districts" ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...." ❑ "Reroof' Permit Tech: Plan Reviewer: 4%� Date: Q • W W= 0 coo W= -IH CO u . W0 J • ? N d • W Z � W • W U 0 O I— WW tL IIJ U 0) Off" Z DEPARTMENTS: Building Division Public Works Complete Please Route Approved Approved \PRROUTE.DOC 5/99 I PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D01 -334 DATE: 10 -11 -01 PROJECT NAME: VALCO GRAPHICS, INC - BLDG A SITE ADDRESS: 480 ANDOVER PARK EAST XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # — Revision # After Permit Is Issued TUES /THURS ROUTING: REVIEWER'S INITIALS: REVIEWER'S INITIALS: et CORRECTION DETERMINATION: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Comments: Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Planning Division Permit Coordinator DUE DATE: 10 -16-01 Not Applicable n No further Review Required DATE: DUE DATE 11 -13 -01 Approved with Conditions Not Approved (attach comments) DATE: if) ' ('l -01 Approved with Conditions n Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DUE DATE WV IVIO W4§104y1X:'S'gs04 .' GRCM+N' t1740.t$ t4dL z ,_z: w • -J U O. N 0. wi • • u_ w O. u_Q za I -w Z �. .z o Lu ,O N ci w H — O . w z - • =` O I z C. PLAN REVIEW /ROUTING SLIP 'ACTIVITY NUMBER: D01 -334 DATE: 10 -11 -01 PROJECT NAME: VALCO GRAPHICS, INC - BLDG A SITE ADDRESS: 480 ANDOVER PARK EAST XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division ri Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: TUES /THURS ROUTING: Please Route \PRROUTE.DOC 5/99 REVIEWER'S INITIALS: Fire Prevention Structural Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 10-16-01 Not Applicable No further Review Required DATE: I (-) — Z.: O DUE DATE 11 -13 -01 Not Approved (attach comments) n DATE: DUE DATE Not Approved (attach comments) n DATE: CTIVITY NUMBER: D01 - 334 DATE: 10 -11 -01 PROJECT NAME: VALCO GRAPHICS, INC - BLDG A SITE ADDRESS: 480 ANDOVER PARK EAST XX Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete PLAN REVIEW /ROUTING SLIP n • Comments: TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIAL - 'V APPROVALS OR CORRECTIONS: (ten days) Approved \PRROUTE.DOC 5/99 Fire Prevention Approved with Conditions CORRECTION DETERMINATION: Approved n Approved with Conditions Structural n Permit Coordinator Incomplete n Not Applicable n Planning Division DUE DATE: 10-16-01 No further Review Required DATE: j ((.0 DUE DATE 11 -13 -01 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE C, Project Name /Ter anL Y4L 2 R API i e : Z/0 ' -.z Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family jgWarehouse El Hospital ❑ Church 71 Manufacturing ❑ Motel /Hotel Ea Office ❑ School /College /University ❑ Other Value of C nstruction: //J Site All (i Il de suit nll er) �- C ' � City Stale /Zip: p �v 1i G / )40 6 9. G �> Tax Parcel Number ;. 2:;4'3 Property Owner: -�t-C /i r 4/1-1_) Will there be rack storage? 171 yes ❑ no Ph o n e sti / '2 -5 7_C- 3 ) Street lc re - , r City State /Zip: � ` ")I; ►aa 4L0, C / 4,,,j,t, , />L 6 /�ti Fax (l: 7 ,- ZC�( - 5 -35 5' Contractor: • I ! 3t , l 61 Phone« J - 4112- r d q StreA c s p ee, 7:96)", ,, i,. v49.5793 Cit State /Zip: Fax It� 47z - 5 Architect: Phone: Street Address: City State /Zip: Fax II: Engineer: Phone: Street Address: City State /Zip: Fax It: Conrt 74 0I LL( 4015— � N .sot./ 4 Phone 12z2 0 Str et Addre .s: �. i - 6 (OState/iP: Fax #t - 7 Description of work to be done (please be specific): .. .w.. j . r7 .4e x t a Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family jgWarehouse El Hospital ❑ Church 71 Manufacturing ❑ Motel /Hotel Ea Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi - family ,I Warehouse CI Hospital ❑ Church ;Manufacturing El Motel /Hotel DI Office ❑ School /College /University ❑ Other Building Square Feet: existing No. of Stories: Area of construction (sq ft): Will there be a change of use? ❑ yes If If yes, extent of change: (Attach additional sheet if necess ry) f � �-Y �' ; �/ST�e �' � ��ja; O � r Will there be rack storage? 171 yes ❑ no Existing fire protection features: sprinklers ,1 automatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable /combustible hazardous material in the building? ❑ yes jg no Attach list of materials and storage location on separate 8 //2 X 1 1 paper indicating quantities & Material Safety Data Sheets Project Number: Permit Number: bo Commercial / Multi - Family Tenant Improvement / Alteration Permit Application ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vaulq#t: ❑ Land Altering 0 Cut cubic yds. ❑ Sanitary Side Sewer It: Cl ❑ Storm Drainage ❑ Street Use ❑ ❑ Water Meter /Exempt it: Size(s): ❑ Water Meter /Permanent It Size(s): ❑ Water Meter Temp It Size(s): ❑ Miscellaneous Size(s): 0 Fill Sewer Main Extension Water Main Extension 0 Deduct Est. quantity: ❑ Flood Control Zone ❑ Hauling cubic yds. ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with cur rent fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: io - VA IP o Date application expires: ie /%02 Application taken • (initials) PLEASE SIGN BACK OF APPLICATION FORM 11 /30 /u0 clperu,ir.du• CITY OF TUVWILA Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431-3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) IYIMI -. ' a' hW" +.��ttl7�.b7h7PIC4'4 <anl Z W J U O 0 CO W J l- W W O 2 � I • W Z = I- O W I-- D p O (12 al— W w I-- H W Z LU • to O ~ Z c BUILDING O J f ' AUTHORIZED AGENT: Signature: I ` �� /, Ara lt f Date: Id 7e if, �L'11 Print name: IL . J 1 L L/ S l � Ph c � ` /�, 8- ,/ %5 �-� l' 7 Fax Ii ,017 -77_ e3 5 ,,/ �7 1 � �� Address �� / 2 d ,`�' t / ,�' �f �T 1�s r/ 14 /2 7 City /State /Zi 1 1 'r Ill. RC' 't� APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER Al ; 1 11N,I��ICI ,4S ALL BE AT A LEGIBLE SCAL D NWL DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 113.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use = only) Z 11. Location and gross floor area of existing structure with dimensions and setback It 12. Lowest finished floor elevation (if in flood control zone) U 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). U O ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled U W W J ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of to tL any hazardous materials; dimensions of proposed'tenant space. w O ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack = d layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of F' _ rack. Structural calculations are required for rack storage eight feet and over. Z ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished w • t j ❑ ❑ Construction details U • U Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water CI F- LU supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed U sprinkler system design criteria as identified by the Fire Department. w_ Z LLI F— O I ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ in Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ Cl Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF 11/30/00 clpermi►.duc PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. * Z MANAGEMENT, INC. Ken Nelson City of Tukwila 6300 Southcenter Blvd, Suite #100 Tukwila, WA 98188 Dear Ken: Re: Demo Permit #DO -334 Confirming our discussion of February 10, 2003 regarding our demolition permit for VALCO GRAPHICS at 480 Andover Park E. Our electrical contractor has completed the removal of unused and abandoned conduit, wiring, etc. on the nonload bearing partition wall covered under this permit. Because of production demands for the plant operations we were unable to schedule the full demolition of the wall prior to the scheduled expiration of this permit. In out conversation, you had agreed that this preliminary start of work would extend our permit period to complete the work for an additional 180 days...I.have,enclosed a letter from Evergreen Pacific Electric, Inc. Indicating the electrical demolition that has been completed. If you have any questions or comments, please give me a call. Enclosure TELEPHONE: TACOMA 253 - 922 -0774 • FAX: 253 - 922 -0334 MAILING ADDRESS: P.O. BOX 1697 • TACOMA, WA 98401 -1697 OFFICE ADDRESS: 6010 20th ST. E., SUITE 5 • FIFE, WA 98424 Very truly yours, EXPA MANAGEMENT, INC. F.H. Williams President ) \11 0 „ v jt y�D 0111c2E .. 6AQPV° -4. RECEIVED FEB 2 4 2003 COMMUNITY DEVELOPMENT February 21, 2003 �:, Evergreen Pacific Electric Co., Inc. Expansion Management, Inc. P.O. Box 1697 Tacoma, WA 98401 -1697 Attn: Harold Williams RE: Valco Graphics- Demo Work We have completed the demo work at Valco Graphics relating to demo permit #D01 -334. We have removed all the unused conduit and wire associated with the walls to be removed. If you have any questions or need more information, please let us know. Th nk you, Da Curnow President February 21, 2003 10409 Canyon Rd E #1 Puyallup Washington 98373. 253 539 -1414 F.H. (Harold) Williams 6010 20th Street East, Ste #5 Fife, WA 98423 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Application No. D01 -334 480 Andover Park East Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time. extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to February 26, 2003, your pemiit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. D01 -334 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Soutlicenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 - 431 - 3665 : 1 "w 6 J U: U0 : N 0 . N W W I W • 0 g iu_ Q- H W . ZH 1— 0 Z F— W W D o: O — 'p t.. W W I v •• O .. Z W OH : Z C Valco Graphics at 480 Andover Park East, recently purchased the entire building and property of 500 Andover Park East so as to expand the warehousing, production and office functions of their business. DEMOLITION PROPOSED: 500 ANDOVER PARK EAST Remove 100 LF of mezzanine structure located on South half of building. Remove 100 LF of partition wall located on the East -West building centerline. Remove existing inefficient lighting and heating equipment contained within warehouse portion. Remove existing office ceiling grid system, and inefficient lighting equipment in office area. Cut new access doorway on North wall. i • p r atq aipfitt bri 4 . ROY 6'.•A�CT..: ;t�:�v�Y?i�,n �} .,�.,. r;C.r.r *•r nip "<�f,'':r iv +�' iCzcf�.. -nw.r µ�-n f ex wall located tn w ehouse a ST 80 & 500 ANDOVER Remove existing covered passageways between buildings. Remove concrete sloped floor between buildings. File: mm Drawing# September 6, 2002 Mr. F. H. Williams Expansion Management, Inc. P.O. Box 1697 Tacoma, WA 98401 -1697 RE: Request for Extension — Permit No. D01 -334 Valco Graphics, Inc. — 480 Andover Park East Dear Mr. Williams: This letter is in response to your written request for an extension to Permit No. D01 -334. The City of Tukwila Building Division will be extending your permit to February 26, 2003. Please be advised that this will be the only extension granted for this project. If you should have any questions, please contact our office at (206) 433 -3670. Sincerely, Robert Benedicto Building Official RB /sks File: Permit No. D01 -334 Bob Benedicto, Building Official City of Tukwila 6300 Southcenter Blvd, Suite #100 Tukwila, WA 98188 Dear Mr. Benedicto, Re: Permit Application No DO1 -334 VALCO GRAPHICS, INC. 480 Andover Park East I am writing in response to the City's letter of August 14, 2002 concerning this permit. This work approved is for the demolition of an interior partition wall in the manufacturing portion of the building. This work can not be done until work in the adjacent building at 500 Andover Park E (Permit DO1 -335) is adequately completed, so that the manufacturing equipment can be relocated from the 480 Building to the 500 Building. This work at the 500 Building is currently in process with the expectation that the equipment can be relocated during October. Based on this, we are hereby requesting that you approve an extension of 180 days for permit DO1 -334 so that we may complete the sequential construction and demolition required between these two buildings for the combined operations of VALCO GRAPHICS. If you need any additional information in order to process the extension request please give me a call at 253- 922 -0774. I look forward to your approving the request. Very truly yours, EXPANSION MANAGEMENT, INC. C. &kw F. F.H. Williams President TELEPHONE: TACOMA 253 - 922 -0774 • FAX: 253 - 922 -0334 MAILING ADDRESS: P.O. BOX 1697 • TACOMA, WA 98401 -1697 OFFICE ADDRESS: 6010 20th ST E., SUITE 5 • FIFE, WA 98424 August 21, 2002 RECEIVED AUG 2 6 2002 COMMUNITY DEVELOPMENT August 14, 2002 F.H. (Harold) Williams 6010 20th Street East, #5 Fife, WA 98423 RE: Permit Application No. D01 -334 480 Andover Park East Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • CaII the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next/final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to September 9, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania"Spencer Permit Technician Xc: Permit File No. D01 -334 Bob Benedicto, Building Official City of Tukwila Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 - 431 -3665 Steven M Mullet, Mayor w re "U O v1� W = '. J I.- WO g J ' ; co u. d � W Z � Z 0 �.. 2 j. U� O N W lU', Z IL . Z W ' U rz. O Z doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049093 Permit Number: D01 -334 Address: 480 ANDOVER PK E TUKW Status: ISSUED Suite No: Applied Date: 10/11/2001 Tenant: VALCO GRAPHICS, INC - BLDG A Issue Date: 03/13/2002 1: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 3: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (248- 6630). 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any con- struction. These documents are to be maintained and avail- able until final inspection approval is granted. 6: ** *FIRE DEPARTMENT CONDITIONS * ** 7: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 8: All interior demo debris must be removed prior to demo of the automatic sprinkler system. Contact the Tukwila Fire Prevention Bureau at 206 - 575 -4407 for an inspection of the building prior to shut down of the automatic sprinkler system. 9: Maintain fire extinguisher coverage throughout. 10: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 11: No point in a sprinklered building may be more than 250 feet from an exit, measured along the path of travel. (UBC 1004.2.5.2.2) 12: Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1003.2.8.4) 13: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 14: Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) 15: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 16: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 17: THESE PLANS WERE REVIEWED BY INSPECTOR 512. IF YOU HAVE ANY QUESTIONS, PLEASE CALL THE TUKWILA FIRE PREVENTION BUREAU AT (206)575 -4407. D01 -334 Printed: 03 -13 -2002 ,,. - .nwr v: Ci': v�• er'+n v14' r+•, rx+ vr�n, �e�• rh! wM�f NUron- vnrl,+f4rtN4xrh +. +�s'n4rYv • 1 w : -JU O 0 N 0. W = J H : U) V.. w u. z F. 1— 0 z I- uj U0 O N O I-- W uj • 0 LL. W Z : U O ~ z doc: Conditions City of Tukwila Et(Q11,60 D01 -334 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 1 hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construc e performance of work. Signature: Print Name: Date: 314, . Printed: 03 -13 -2002 ............ • F625-052-000 (8/97) . • ^ Detach And Display Certificate REGISTEREDAS PROVIDED BY LAW A CONST CONT - GENERAL REGI ST .2 #-. - EXP . DATE CCO1'.P WMDICC*108J7. 04/01/20,02. -EFFECTIVE7 • 04/27/1990 WM7DICKSON: 3315 S TACOMA WA', T, 984 09 • , . • -" . .' • Issued by DEPARTMENT OF LABOR AND INDUSTRIES Signature Please Remove And Sign Identification Card Before Placing In Billfold NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. riN ft ACTIVITY NUMBER: D01 - 334 DATE: 10 -11 -01 PROJECT NAME: VALCO GRAPHICS, INC - BLDG A SITE ADDRESS: 480 ANDOVER PARK EAST XX Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building 'vision G 10 Public Works 14n Alk 104P-0( DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete TOES /THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention f Structural Approved with Conditions Approved with Conditions REVIEWER'S INITIALS: Planning Division 10 Permit Coordinator DUE DATE: 10-16-01 Not Applicable Comments: No further Review Required DUE DATE 11 -13 -01 Not Approved (attach comments) Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DATE: DATE: DUE DATE 'October 4, 2001 Validated by: shong Tax Parcel ID # 2623049093 (480 Andover Park East) Owner: RWV Properties 480 Andover Park East Seattle, WA 98188 Tax Parcel ID # 2623049097 (500 Andover Park East) Owner: Valentine /Walker Properties 480 Andover Park East Seattle, WA 98188 Valco Graphics, Inc. — 480 Andover Park East • Seattle, WA 98188 — 206 575 -3500 • f 206 575 -3575 printing • mailing • fulfillment ...1.._r. ,.... ...,... «..r•xc��'tiA4yacii�lf. �'l;!S•:t; %k::,.....i:..`.t October 4, 2001 To Whom It May Concern: This letter serves as authorization for F.H. Williams of Expansion Management Inc to act as our agent for the submittal of the necessary demolition and tenant improvement permit applications, as well as obtaining these permits on behalf of Valco Graphics, Inc. and the property owners, RWV Properties and Valentine /Walker Properties. 1 ruce A. Walker RWV Properties Valentine /Walker Properties Valco Graphics, Inc. PUBLIC I. P:41 mica Valco Graphics, Inc , — 480 Andover Park East . Seattle, WA 98188 —t 206 575 -3500 . f 206 575 -3575 printing • mailing • fulfillment LICENSE DETAIL INFORMATION Form STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License WMDICC *108J7 Name WM DICKSON CO Address 3315 S PINE ST Address City TACOMA State WA Zip 98409 Phone Number 2534724489 Effective Date 4/27/90 Expiration Date 4/1/02 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code GENERAL Other Specialties UBI Number 278045472 * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * • * * *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * 'CHECK *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page https://wws2.wa.gov/Ini/bbip/TF2Form.asp?License=WMDICC*108J7 Page 1 of 1 10 /11 /01 r• r - • • *A4:40.***4*AA—.14**A tit4c4+ **4*******A*A.A—Ici**4* CITY OF TuKwrLA,, WA TRANSMIT isA**A4tiv.k.,4 4. ***4;4 4—A.A*4 A**Age-ivic 1 IMSMIT Number: R0101323 Amount: 63.21 10/11/01 0940 Payment Method: CHECK Notation: EXPANSION MONT ini h: SKS --.• Perm i b No D01-334 Type: DEVPEItM DEVELOPMEJ4T PEtiMIT Parcel No 262304-9093 it Address: 480 NDOVD Pt E '• • Total Fees: 164.96 -:.PaYmerit 63.21 Total ALL Potts: •.' , • P, al aiice; 101.75 , A4.0*:+k 2 4c*A***,4***1 4.*+it***********0 ***A i*A-1k*.Alcir•A 41k 4.******* Descri pt ion PLAN CHECK '10NRES • Amount • ..•63.21 • • Parcel No.: 2623049093 Permit Number: D01 -334 Address: 480 ANDOVER PK E TUKW Status: APPROVED Suite No: Applied Date: 10/11/2001 Applicant: VALCO GRAPHICS, INC - BLDG A Issue Date: Receipt No.: R020000341 Payment Amount: 101.75 Initials: KAS Payment Date: 03/13/2002 09:40 AM User ID: 1684 Balance: $0.00 Payee: EXPANSION MANAGEMENT, INC. TRANSACTION LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Amount RECEIPT Type Method Description 0 Payment Check 3515 101.75 ACCOUNT ITEM LIST: Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE Description Account Code 000/322.100 97.25 000/386.904 4.50 Total: 101.75 4773 03/14 V7.1.6 TOTAL 645.07 Printed: 03 -13 -2002 File: DO I 33L1 35mm Drawing# 4 I understand that the Plan Check approvals are subject to errors and omissions and approval of plans p d c authorize any adopted a code tractor's co •'1P ed plans acknowledged, PROJECT: 2109 VALCO GRAPHICS 1 3O 15.0 FACE OF L., 1111;1111m - T r {� EIOSTIN BREEZE TO BE EXISTING BUILDING 'A" DOSING PL.Nr TO REFW N REMOVE EXISTING PARTITION WALL 480 ANDOVER PARK E. EXISTING OFFICE TO REMAIN—) (Z HR) MASONRY WILL — ALL DOORS ALONG BUILDING P: PLANT SOUTH WALL TO BE REPLACED W/ FIRE -RATED NEW ASSEMBUES BUILD EXP" ANDOVER PARK E. INFILL EXLSTIN f NEW ROOF ASSEMBLY OVER TRUCK ACCESS DRNE ! BETWEEN EXISTING BUILDINGS A E B NEW WALL ASSEMBUES AT EAST E WEST ENDS • BETWEEN EXISTING BUILDINGS A E B EXISTING CONCRETE TRUCK ACCESS DR VE TO BE REMOVED AND REPOUREDWTTH NEW CONCRETE SLAB •Ill EXISTING MAN DOOR d J TO BE REPLACED W/ NEW14X12 OPENING NEW SHIPPING OFFICE EXISTING PARKING E LANDfq• GAPING TO REMWN DEMO MEZZANINE ABOVE 1 500 ANDOVER PARK E1 NEW TOILET, PLANT LUNCHROOM E PRODUCTION OFFICE CONFIGURATIONS WITHIN EJOSTING SHELL NEW OFFICE CONFIGURATION • WITHIN EXISTING SHELL SOUTH CENTER MALL ADJACENT BUILDING EU ANDOVER PARK E. PROJECT SITE SOUTHCENTER PKWY. SITE PLAN GENERAL PROJECT SCOPE SCALE V = 30' -0" ALLOWABLE BUILDING AREA - BUILDING "B" EXISTING BUILDING "B" AREA = ADDED AREA FOR BUILDING "B" EXPANSION TOTAL =, ALLOWABLE UBC TYPE 5Z N ALLOWABLE _ 2 -SIDED SET BACK > 20-0" 54 - 20 = 34 (1.25) = 42.5% (8,000) _ TOTAL= NOItS: 26,000 SQ. FT. = 4,800 SQ. FT. 30,800 SQ. FT. 8,000 3,400 11,400 UBC TYPE SL-N SPRINKLED 11,400 (3) 34,200 S0. FT. ALLOWED 34,200 SQ. FT. > 30,800 SQ. FT. 1. THIS DRAWING SERVES TO IDENTIFY THE OVERAL-L SCOPE OF PROJECT WORK. SEE ATTACHED ENLARGED PLANS $ STUDIES FOR SPECIFIC SCOPE, 2, SEE STRUCTURAL, MECHANICAL E ELECTRICAL DWGS. FOR SPECIFIC SCOPE IN EACH DISCIPLINE BEYOND THIS OUTLINE. 3. ALL DWGS. ARE BASED ON OWNER pROVIDED AS- BUILTS $ LIMITED FIELD MEASUREMENTS. CONTRACTOR 15 RESPONSIBLE FOR VERIFYING ALL CONDITIONS PRIOR TO COMMENCING, WORK. lil L I' LLII( 1 IIIIIIIIII � I I 1 1 1 1 1 I 1 1 1 1' 1' 1' 1I lt` 1 I 1 1 1 ILi�Illilllill . l . LILIT'�j�I 1 �i . IlllIll 1 1 .,1 a r " D CNINA 1 �y (r 113 ` , . 6 6 9L VL CL EL s. VICINITY MAP NOT TO SCALE VALCO GRAPHICS CORPORATE OFFICE TENANT IMPROVEMENTS 480/500 ANDOVER PARK EAST TUKWILA, WASHINGTON OWNER: VALGO OWNERS REPRESENTATIVE HAROLD WILLIAMS EXPANSION MANAGEMENT, INC. PHONE: 253- 922 -0774 FAX 253- 922 -0334 MAIL: P.O.B. 1697 TACOMA, WA 98401 -1697 OFFICE: 6010 20TH ST. E., SUITE 5, FIFE, WASHINGTON 98424 ARCHITECT: JON GRAVES ARCHITECTS $ PLANNERS 2112 NORTH 30TH STREET., SUITE B TACOMA, WASHINGTON 98403 TEL,(253)- 272 -4218 FAX. (253 )-272 -4218 MECHANICAL/ELECTRICAL ENGINEER BCE ENGINEERS 3601 20TH ST, E. SUITE 1 TACOMA, WASHINGTON 98424 TEL. (253) - 922 -0446 FAX. (253) - 922 -0896 STRUCTURAL ENGINEER CHALKER PUTNAM COLONS E SCOTT 950 PACIFIC AVE., SUITE 200 TACOMA WASHINGTON 98402 TEL. (253) -383 -2797 FAX. (253 )-383 -1557 LEGAL DESCRIPTION: THE LAND REFERRED TO IN THIS COMMITMENT I5 SITUATED IN THE STATE OF WASHINGTON, THE COUNTY OF KING AND IS DESCRIBED AS FOLLOWS PARCEL A : 480 ANDOVER PARK EAST THAT PORTION OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS : BEGINNING AT THE SOUTHWEST CORNER OF TRACT 8, ANDOVER INDUSTRIAL PARK NO. 5 ,ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 83 OF PLATS PAGES 22 AND 23, RECORDS OF KING COUNTY WASHINGTON THENCE SOUTH 01" 47 28" WEST 225.00 FEET ; THENCE SOUTH 88' 12 32" EAST 29700 FEET ; THENCE NORTH 01' 47 28' EAST 225:00, FEET TO THE SOUTHEAST CORNER OF SAID TRACT 8 ; THENCE NORTH 88'12 32' WEST 297.00 FEET TO THE TRUE POINT OF BEGINNING. PARCEL B: 500 ANDOVER PARK EAST THAT PORTION OF THE NORTHEAST CL i.KitR OF THE SOUTHEAST QUARTER: OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS : BEGINNING AT THE SOUTHWEST CORNER OF LOT 8 PLAT OF ANDOVER INDUSTRIAL PARK NO. 5, ACCORDING. TO THE PLAT THEREOF RECORDED IN VOLUME 83 OF PLATS, PAGES 22 AND 23,' RECORDS OF KING COUNTY, WASHINGTON. THENCE SOUTH or 47 28" WEST ALONG THE SOUTHERLY EXTENSION OF THE WEST LINE OF SAID LOT 8 A DISTANCE OF 225.00 FEETTO THE TRUE POINT OF BEGINNING THENCE SOUTH 88' 12 32" EAST A DISTANCE OF 297.00 FEET ; THENCE NORTH 01' 47 28' WEST A DISTANCE OF 170 FEET THENCE NORTH 88'12 32" WEST ADISTANCE OF 297.00 FEET ; THENCE NORTH 01' 47 28" EAST A DISTANCE OF 170 FEET TO THE TRUE POINT OF BEGIN BOTH SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. NOTE - BOTH PARCELS SUBJECT TO ,AN EASEMENT OF 15 FEET ON WEST FOR UTILIl1ES AND AN EASEMENT OF 27 FEET ON EAST FOR RAILROAD. THIS EASEMENT TO CENTERLINE OF LEAD SPUR. PROJECT INFORMATION: ZONING; CITY OF TUKWILA TUC BUILDING CO DE; 1997 UBC OCCUPANCY. P -1 TYPE OF CONSTRUCTION: V-N (FULLY SPRINKLED) DRAWING INDEX:, Ti COVER A1,1 PROPOSED TENANT IMPROVEMENTS TO BLDGS, 'A" $ 'B" A1.2 ENLARGED PLANS - BLDG: 'B' / ENLARGED TOILET ROOMS A13 <1 ENLARGED 1ST FLOOR PLAN $ ROOF PLAN OF EXPANDED BLDG. 13' W/ BUILDING SECTION A1.4 EXTERIOR ELEVATIONS,' DOOR SCHEDULE, WINDOW TYPES $ DETAI 51.0 ,STRUCTURAL NOTES 52.0 STRUCTURAL' FOUNDATION '$` ROOF PLANS 53.0 STRUCTURAL:. FOUNDATION DETAILS $ SECTIONS 54.0 STRUCTURAL ROOF DETAJL5 E SECTIONS' M 1.1 MECHANICAL NOTES M 2.1 DEMOLITION FLOOR PLAN - 'OVERALL M 2.1 ' DEMOLITION FLOOR PL%AN;- OFFICE $ UNDER MEZZANINE M 3.1 PLUMBING FLOOR PLAN OFFICE M 4.1 HVAC REFLECTED CEILING PLAN - OVERALL. M 4.2 HVAC FURRED CEILING PLAN . OVERALL M 5.01 MECHANICAL DETAILS E 1.0 ELECTRICAL LEGEND $ SCHEDULE • E 2,1 DEMOLITION FLOOR PLAN - OVERALL E 2,2 : DEMOLITION FLOOR PLAN OFFICE $ UNDER MEZZANINE E 3,1 • LIGHTING FLOOR PLAN OVERALL E 3,2 - LIGHTING FLOOR PLAN' - OFFICE E 4.1 POWER FLOOR PLAN - OVERALL E 4.2 POWER FLOOR PLAN OFFICE E 5.1' POWER RISER DIAGRAM E 5,2 POWER PANEL LAYOUTS E 6.0 DROP CORD DETAIL $ UOS WIRING DIAGRAM :,71 SHALL RE' MADE TO D; . W0', .WITHOUT PR :"..":71 r. OVAL OF TUKWILA BUILDING '• DIVISIC)14, NOTE: REVISIONS WILL. REQUIRE A NEW PLAN SUBMITTAL AND MY INGWO ADDITIONAL. PLAN REVIEW FEES. SEPARATE PERMIT REQUIRED FOR: M ECHANICAL LECrRICAL % PLUMBING GAS PIPING' CITY OF TUKWILA BUILDING DIVISION O 'r OF TUKWILA OCT 1 1 2061 PERMIT °D [P12NJ04 �5�4 al in rrnn � VI o W Q Z 3 Z L a I co N . W &itrq > W rnki C Z U. i Qua bi-33 1 LNE OF UPPER OFFICES MIME EXISTING PLANT TO REt-AJN EXISTING PAR1T ICN WALL TO BE REMOVED BUILDING A PLANT 126 PRODUCTION EXISTING OFRC (2 HR) MASONRY NFILL DOOR SIZE 12-0'X REVERSE DOOR SWINGS SEE ENLARGED 1ST FLOOR FLAN IL ROOF FLAN OF THIS AREA DOOR SIZE W'-O' X 12.0' REMOVE EpSTNG 9' X 10 OVERHEAD DOORS $ NFILL OPENINGS W/ MASONRY EXISTING P+KEEZEWAY TO BE REMOVED EX'inNG BREEZE -WAY TO BE REMOVED hill SEE BUILD SECTION FOR FI_OOR N 4 NEW STRUCTURE EXISTING 14' x ip OVERHEAD DOOR TO REMNN DUSTING CLG/ROOF ASSEMBLY II EXISTING CLG CONDITION I-tAS NO R-19B TT NSUTATION II R-19 COVEER B O O AND F9 25 COVER BOARD- EXISTING TOLETS TO REMAIN NEW DOOR UNDERSIDE OF STAR AM ® TOP OF LANDING 101,9 OVERHEAD DOOR To BE REMOVED R VFIU.FA W/ STJCCO CLAD FRAME WALL PAINT STRIRNG ON SLAB T TE EXIT PATH M' NEW PRODUCTION OFFICE ELECTRICAL TO BE RELOCA DOTING 'x12 OVERHEAD DOOR TO REMNN l A'Oi l s I l T i� i �i �i �i 7 WALL LEGEND CONTENTS ARCHITECTURAL PROPOSED OVERALL PLAN ScAie T'-O' DROWN BY: THOM DATE 10-03 -01 REVISIONS FACE OF BLDG. 154 FAGS OF BLDG. r OFFICE 480 ANDOVER PARK E. �OF RAILROAD SPUR PRODUCTION PRODUCTION O REMAIN PRODUCTION PRODUCTION p NEW STEEL STUD FRAME WALLS W/ (2 ) NEW 9 X10 OVERHEAD DOORS ® DOCK HEIGHT ANDOVER PARK E. • I 1iL11it � rl' • 1 'I I I '1 1 � 1 � 1 1 1 �11 1 1 1 ��1 1 1' 1 11 11� '111'111111'�Ii'�'11111111� l x � U CHINA 1` 2 "3 3 ro k1 t, 6 6 9L. bL EL 7.L • FAL OF EXISTING WALL TYPES OVERALL 1ST FLOOR BUILDING PLANS SCALE ':1/16" = 1'-O" PROPOSED NEW WALL. TYPES ( ADJACENT BUILDING ) 51/7 CONCRETE TILT -UP EDRERIOR WALL PANEL 51? CONCRETE TILT -UP EXTERIOR WALL PANEL W /1/7 AR -SPACE ' 2X 4 WOOD-FRAME WALL W/ 5/9' GNB ON INSIDE FACE WALLS ARE INSULATED W/ R-T1 BATr NSULA.TIDN. 2 X 4 INTERIOR WOOD FRAME WALL W /5/9' G\M5 EACH SLOE 7/8' CEMENT PLASTER OVER FELT BACKED WELDED WIRE MESH OVER 1/7 PLYWOOD SHFATHNG OVER 3 5/9' METAL STUD WALL W/ STUDS ®16' O.C. PROVIDE Rd3 HIGH DENSITY BATT NSULATION AND V7 AC PLYWOOD- PLAT FINISH (PWD ® PLANT SIDE TO BE PANTED COLOR PER ARCHITECT) 5/9' GWB ON EACH 5DE OF 3 5/9' METAL STUD WALL W/ STUDS ®16' O.C. FEATURES OR WALLS TO BE REMOVED DUSTING WALLS TO BE RETAINED NEW WALLS VS AC PLYWOOD ON PLANT SIDE OF 3 5/9' METAL FRAME WALL W/ STUDS IP 16' O.C. PROVIDE R-13 HIGH DEN,SLTY BATT INSULATION E 5/9' GWB ON INSIDE FACE 7/9' CEMENT RASTER OVER FELT BACKED WELDED WIRE MESH OVER V7 PLYWOOD SHEATHING OVER 6' METAL STUD WALL W/ STUDS ®16' O.C. PROVIDE R-21 FKGH DENSITY BATT INSULATION AND V2 AC PLYWOOD - PLANT FINISH ( PAM' FWD ®NIERIOR FACE. COLOR PER ARCHITECT) pC 'ANfl4 CIT YOFTU w ow OCT 1 1 2001 PER M PROJECT• 2109 VALCO GRAPHICS oT sheets 4'-6' O i 1 I 122 I 1 I I NEW SHIPPING OFFICE c) WING -WALL TO BE REMOVED WING -WAl TO BE REMOVED OPEN OFFICE LANDSCAPE PROVIDE NEW 1 -1/7 SCHED 40 CONTINUOUS HANDRAILS EA SIDE ® 32' ABOVE ST NOSING DEMO MEZZANINE ABOVE RETAN MEZZANINE ABOVE EXISTING STARWELL TO BE ENCLOSED - PROVIDE ( 2 ) LAYERS OF 5/8' GWB ® UNDER -SIDE OF STARS TO CREATE 1 HR ASSEMBLY NEW PLANT LUNCH ROOM REMOVE ISISENO DOOR AND REUTE PATCH AS REQUIRED COMPUTER EQUIPTMENT _(EXISTING ) OFFICE ( EXISTING ) OFFICE (EXISTING) (E ADD.) PARRTION -WALL TO BE REMOVED 1T.6' MALNG $ DATA PROCESSING (NEW) CONFERENCE (NEW) SCABW . SEE DETAIL AA TOP OF THS SHRIFT MENS RESTROOM SINK 0 EQUIPMENT (NEW) TRAINING ROOM (NEW) SEC eLecrer..I. DW.4NG5 FOR masers* ace DEMO WORK t NEW SUSPENDED 0.6 L1YOVf FORAYMEA5 TO BE RENOVATED 1111111r 11 II111111J11111111111 (' CHINA 1 • ' EPDXY PAINT NEW 18' DEE i x 24' HIGH SCREENS 4,-6' MEN'S 103 ' EPDXY PAINT WOMEN'S 104. 6 CERAMIC TILE BASE WOMEN'S 104 6" CERAMIC TILE BASE NEW 30 " x 36 MIRROR SINK MOUNTED IN LAMINATE FINISHED;; , WALL MOUNTED COUNTER GRAB BAR O MEN'S 103 O MEN'S 103 6" CERAMIC , TILE BASE EPDXY PAINT 3-6' MIN. WOMEN'S 104 WOMEN5104 WOMEN'S 104 ELEVATIONS 1/4" =1.-O• NEW HANDRAILS AILS 5-o• CLEAR INFILL EXISTING 10-6 X 9- O OPENING W/ WALL TYPE TO MATCH ADJACENT WALL TYPE. BUILDING B PROPOSED UPPER MEZZANINE PLAN SCALE: 1/8" =1' -0" NEW DOOR ® UPPER LEVEL USE 800- 5162 -68 ® 16' O.C. IN SHORT DIRECTION FOR CEIUNG FRAMING PROVIDE 3/4 T & G PWD DECK ABOVE CEILING FRAMING REUSE EXISTING SLIDING DOOR FROM MEZZANINE DEMO FOR EXISTING g X 10 OPENING ( IN IDE MOUNT ) STORAGE 100 STARS 201 PROVIDE HARD CEILING ® 9-0' CLEAR FROM FINISHED FLOOR TO UNDER -SIDE OF CEILING STRUCTURE SEE ENLARGED TOILET PLAN 77.0' EAGKSRASH BEE ELEVATION 3T -6' BUILDING B PROPOSED OFFICE FLOOR PLAN SCALE: 1/8" =1' -O" NOTE: UNDER SINK CABINET DOOR TO COMPLY W /ADA CLEARANCE TOE KICK TO BE INTEGRAL W/ CABINET DOORS KITCHEN CABINETS PROVIDE HARD CEILING CP 94 CLEAR FROM FINISHED FLOOR TO UNDER -SIDE OF CEILING STRUCTURE PROVIDE 3/4 T $ 0 FWD DECK ABOVE CEIUNG FRAMING USE BO0- 5162 -68 ® 16 O.G. IN SHORT DIRECTION FOR CEILING FRAMING NEW PANT STRFING ON SLAB TO INDICATE EXIT PATH PROVIDE EPDXY PAINT FINISH ON CONCRETE FLOORS (3) EXISTING URINALS . TO REMAIN IL_ MNS RESTROO 5'-0' ADD TOILET PARTITIONS TO ALLOW FOR NEW DOORS $ STALL DEPTHS EXISTING 360 SINK 14 -7" . \ EPDXY PANT- 6" CERAMIC TILE BASE L +fl1'11ii '11 6 ENLARGED TOILET PLAN 1/4 =1'-0' lO PROVIDE NEW LAMINATE PARTITIONS THROUGHOUT ® TIE NEW WOMENS ROOM PLUMBING INTO EXISTING MENS ROOM SUPPLY AND WASTE 0 PROVIDE NECESSARY BLOCKING IN EXISTING WALLS TO RECIEVE GRAB BARS EXISTING SOLID WALL REMOVE EXISTING TOILET / PATCH FLOOR AS REQ'D. ( 2 ) OTHERS TO R EMAJN g . -3 . 33' EXISTING 3 5/8' FRAME WALLS NEW TOILET PARTITIONS nruie IS I RELITE TO ALLOW FOR NEW CONFIGURATION, PATCH WALL AS REQUIRED NEW SINK E FAUCET IN WALL MOUNTED COUNTER NEW TOILETS PARTITIONS REMOVE EXIST. TOILET PROVIDE NEW GRABBAR PER A.DA EXISTING WALLS TO BE RETANED NEW WALLS OR PARTITIONS NOTE CONTRACTOR IS RESPONSIBLE FOR VERIFYING 7 E18' ADA CLEARANCE REQUIREMENTS ON EACH SIDE OF MAN DOORS. PE LT11 [ U LJ " i PROJECT. 2109 VALCO GRAPHICS V8' =1'-O' DRAWN BV: 1HOM DATE 10 -03-01 EXISTING WALL TYPES 11 1ii1:190147 WALL LEGEND 5 V7 CONCRETE TILT -UP EXTERIOR WALL PANEL 51/7 CONCRETE TILT -UP EXTERIOR WALL PANEL W/ 1/7 AR -SPACE 2 X 4 WOOD -FRAME WALL W/ 5/8' GWB ON INSIDE FACE. WALLS ARE INSULATED W/ R-11 BATT INSULATION. 2 X 4 INTERIOR WOOD FRAME WALL W/ 5/8' GWB EACH 51DE 2 X 6 INTERIOR WOOD FRAME WALL W/ 5/B' GWB EACH SIDE PROPOSED NEW WALL TYPES 7 /B' CEMENT PLASTER OVER FELT BACKED WELDED WIRE MESH OVER 1/2' PLYWOOD SHEATHING OVER 3 5/8' METAL STUD WALL W/ STUDS ® 1E' O.C. FRO' l E R-13 BAIT INSULATION AND I/2' AC PLYWOOD - PLANT FINISH 5/8' SHEET -ROCK SHEATHING OVER 3 5/8' METAL STUD WALL W/ STUDS 8' 16' O.C. V2' AC PLYWOOD ON PLANT SIDE OF 3 5/8' METAL FRAME WALL W/ STUDS 8'16' O.C. PROVIDE R-13 HIGH DENSITY BATT INSULATION $ 5/8' GWB ON INSIDE FACE. 7/8' CEMENT PLASTER OVER FELT BACKED WELDED WIRE MESH OVER I/2' PLYWOOD SHEATHING OVER 6' METAL STUD WALL W/ STUDS 8' 16' 0.C. PROVIDE R-13 HIGH DENSTTY BATT INSULATION AND 1/7 AO PLYWOOD - PLANT FINISH FEATURES OR WALLS TO BE REMOVED MIMI IN ti NEW 4 0 D.S. (2 HR) MASONRY INALL DOOR SIZE 174 X 104 125 SLAB S ELEVAT1O Aft REVERSE DOOR SWINGS W/ NEW DOO o 2 125 t REPLACE EXISTING DOORS W/ 11/2 HR FIRE RATED ASSEMBUES ( SEE DOOR SCHEDULE, SHEET A1.4 ) DOOR SIZE 14'-a x 174 NEW 4' (D-0- SLAB SPOT ELEVATION (C) e NEW WALL ASSEMBLY REMOVE EXISTING e' X 10 OVERHEAD DOORS ff INFlLL OPENINGS W/ MASONARY 1 EXISTING BREEZE -WAY TO BE REMOVED WARP RAMP DOWN EXISTING BREEZE -WAY TO BE REMOVED WARP RAMP DOWN PLANT NEW 0 D.S. NEW 4' 0 D.5. NEW DOCK LEVELER DATUM NEW SLAB • SPOT ELEVATION (A.By2 WARP RAMP NEW 4' 0 DS. \ UP 125 BUILDING "B" EXPANSION DEMOLISH EXISTING SLAB - POUR NEW CONCRETE SLAB W/ RAMPS TO OPENINGS AS CALLED FOR DATUM NEW SLAB SPOT ELEVATION (CnP'2 v .' ?' ), a NEW ( WAIL ASSEMBL WARP RAMP UP NEW DOCK LEVELER O ENLARGED GROUND FLOOR 8'-0 SLAB SPOT ELEVATION (B) EXISTING MAN DOOR TO REMAIN 4 SLAB SPOT _ ELEVATION (D) 8' OVERHEAD DOOR E REMOVED E INFI • TUCCO CLAD FRAM PROVIDE HARD CEILING ® 50 CLEAR FROM FINISHED FLOOR TO UNDERSIDE OF CEILING STRUCTURE PROVIDE 3/4' T ff G DECK ABOVE CEILING FRAMING USE 800. 5162 -68 i' 16 O.C. FOR CEIUNG FRAMING RE AUGN WALL W/ EAST FACE OF PILASTER EXISTING 14' x 10 OVERHEAD DOOR TO REMAN PLAN - 11124 REMOVE MAN DOOR CUT NEW 14 X12 OPENING FWSH- OUT OF CEMENT PLASTEF W/ ADJACENT CONCRETE WALL FACE ENLARGED MEW v7a FLUSH -OUT CEMENT PLASTER FINISH W/ FACE OF ADJACENT CONCRETE PANEL ENLARGED FLOOR PLAN NEW PRODUCTION OFFICE EXISTING ROOF TO REMAIN 11231 01 II d A fOir 11 CONTINUE EPDM UP SIDE WALL ff UNDER ROOF EDGE FLASHING BUILDING "A' •/ EXISTING 5 V2' CONCRETE WALL EXISTING BLDG. A SLAB TO REMAN EXISTING CONCRETE FOOTING —J 8' OVERHEAD DOOR E REMOVED ff INFlLL •TUCCO CLAD FRAM NOTE : NEW 4' 0 DOWN - SPOUTS SHALL ALL BE PVC TIGHT LINED TO EXISTING 4 0 DRAIN SYSTEM. NEW 64./- CRICKET PROVIDE NEW EDGE PLASHING ROOF CRICKETS TO SLOPE 1/4 PER FOO1 1\ OVER 6'4 N- EXISTING CONCRETE PILASTER BEYOND EXISTING WALL TO BECOME ( 2 ) HOUR BUILDING SEPARATION WALL RAMP DOWN TO BLDG P: SLAB O BUILDING SECTION v• 0 1'4 SEE STRUCTURAL 51.0 520 53.0 PROVIDE V7 PWD. SHEATHING ON INSIDE FACE OF WALL EXPANSION ROOF 11 � , 4 .• 1 4. M CONTINUE EPDM MEMBRANE UP E OVER PARAPET WALL SY STEM NEW BAR JOISTS SEE STRUCTURAL S1.O 520 S4.0 O ROOF DRAIN OVERFLOW 3/4' = T-0' 304 NEW ROOF TO SLOPE V4' PER FOOT OVER 304 BUILDING "B" EXPANSION REPLACE EXISTING SLAB W/ GRADES AS SHOWN IN ENLARGED PLAN I11111111-I�' 1F11 111111111 �IILIIIIII!I��I�(II�I CHINA 1 5C bl EL Z1 PRE - FINISHED METAL PARAPET CAP - INSTALL W/ CONTINUOUS CLEAT P OUTSIDE FACE AND INTERMITTENT FASTENERS eP INSIDE FACE MATCH VERTICAL FACE OF EXISTING PARAPET GAP 2 X CONTINUOUS NAILER PLATE 7/8' CEMENT PLASTER OVER FELT BACKED WELDED WIRE MESH OVER V7 PLYWOOD SHEATHING OVER 6' METAL STUD WALL 'W/ STUDS 016 FLASH EPDM MEMBRANE INTO 4• DLA OVERFLOW SLEEVE LOCATE O. 0 ROOF ELEVATION 1 V7 ABOVE ROOF DRNNS NEW 41 ROOF SECTION MECHANIGALY FASTENED EPDM SHEET ROOFING AdIEVAMEMIIIP211111WAYAV RAMP UP TO BLDG •B• SLAB BUILDING'A BUILDING'S' EXPANSION 1 i, 1 1?'1 1 1 1 11111',x 1 .1 II 1 1 1!1 1 1 1 1 1 1' 1 Ii1'1 1 1 1 1 1 1!111 .,amp v17 41 5 • 6 :..,6 "..i .;'b c am . !L1" ._i ,/ / O ROOF DRAIN 3/4' 1-0 PROVIDE NEW R49 BATT INSULATION - NORTH 70 BETWEEN EXISTING ROOF JOISTS PROVIDE NEW FS25 COVER BOARD 0 UNDERSIDE OF JOISTS 11RU -OUT PLANT CFJUNG CONTINUE EPDM UP SIDE WALL TO SURFACE MOUNTED REGLET LOCATED'' HGT. OF AwlITONS 1 VO:APET WAtl. BUILDING "B" EXISTING 51/7 CONCRETE WALL EXISTING CONCRETE PILASTER BEYOND EXISTING CONCRETE FOOTING 4'0 PPE ROOF DRAIN W/ MESH SCREEN ROUTE TO LOCATIONS AS CALLED OUT ON PLANS BUILDING 'B' TERMINATE EXISTING 4' 0 DOWN UT FROM BLDG A ROOF ' NEW ROOF. PROVIDE SPLASH BLOCK. TERMINATE EXISTING 4' 0 DOWN 5PO FROM BLDG O: 0 NEW ROOF. PROVIDE SPLASH BLOCK TRIBUTARY AREA VS NO, OF DOWN - SPOUTS REQUIRED, BUILDING A • 4750 BUILDING '13' EXPANSION 4800 BUILDING 'B' ' 11200 20750 400. 51,875 / 12.57 SQ. IN. =4.126 4' 0 D.S. REQUIRED ( 5') 4" 0 D.S. SHOWN BUILDING A ROOF DRAIN OVER -FLOW 4'0 ROOF DRAIN COORDINATE ROOF PENETRATIONS W/ ROOF FRAMING MEMBERS SLOPE ® 4' PER 1'-0' CRICKET SLOPE 61 4 PER 1'4 4' 0 ROOF ORAIN SLOPE V.1' PER 1'4 cwc CRC SLOPE ,., 1/4 PER 1'4 4' 0 ROOF DRAIN SLOPE 0 V4' PER TO EE CRC CRIC SLOPE 0 4 PER 1'4 4'0 ROOF ORNN SLOPE 0 I/4' PER T4 GRID CRIc SLOPE 0 4' PER r4 4 ROOF DRAIN NEW EPDM ROOF BUILDING "B" EXPANSION ROOF AN OVER.F LO W e ENLARGED ROOF PLAN SLOPE O V4' PER 1'-O' TERMINATE EXISTING 4'0 DOWN SPOUT n ® NEW ROOF. PROVIDE SPLASH BLOCK' SLOPE ® V4' PER r• TERMINATE EXISTING 4' 0 DOWN SPOUT NEW ROOF.. PROVIDE SPLASH BLOCK SLOPE ' V4' PF({f;PL +;�,. EXISTING WALL TYPES 1 d 9 . ig 1 i Ti I iii i t WWI Wite OJ tfliVet7 WALL LEGEND BUILDING "B" 5 V7 CONCRETE TILT-UP EXTERIOR WALL PANEL 5 1/7 CONCRETE TILT -UP EXTERIOR WALL PANEL W/ V7 AIRSPACE 2 X 4 WOOD - FRAME WALL W/ 5 /6 GWB ON INSIDE FACE WALLS ARE INSULATED W/ R-11 BATT INSULATION. 2 X 4INTERIOR WOOD FRAME WALL W/ 5/8' GWS EACH 51DE PROPOSED NEW WALL TYPES 7/8' CEMENT PLASTER OVER FELT BACKED WELDED WIRE MESH O OVER 1/7 PLYWOOD SHEATHING OVER 3 5/8' METAL SW WAIL W/ STUDS ®16 O.G. PROVIDE R-13 HIGH DENSITY BATT INSULATION AND V7 AC PLYWOOD - PLANT FINISH 5/8' GWB EACH SIDE OF 3 5/8' METAL STUD WALL W/ STUDS 41 O.C. FEATURES OR WALLS TO BE REMOVED EXISTING WALLS TO BE RETAINED NEW WAL ROOF , SYSTEM.' EPDM SHEET ROOFING OVER V7 FIBER - BOARD ((� 1U1WW" OVER 3' RIGID INSUVI(I 1RO' OVER V7 GW8 f�ttCC OVER TYPE TT' METAL DECK. $ % ' Ot \ , 13 \V 1ss a w ! r 1/7 AC PLYWOOD ON PLANT SIDE OF 3 5/8' METAL FRAME WALL W/ STUDS 016'. PROVDE R•13 HIGH DENSITY BATT INSULATION It 5/8' GWB ON INSIDE FACE 7/8' CEMENT PLASTER OVER FELT BACKED WELDED WIRE MESH OVER 1/7 PLYWOOD SHEATHING OVER 6 METAL STUD WALL W/ STUDS 016 O.G. PROVIDE R-21 HIGH DENSITY BART INSULATION AND V2' AC PLYWOOD - PUNT FINISH. ern OF T OCT 1 1 200i PERMIT li PC G3D10i' gIEU PROJE6T 2109 VALGO GRAPHICS CONTENTS Al PROPOSED PLANS & SECTIONS BLDG.' B' SCALE 1/8'm T-0 DRAWN BY THOM DATE 10-03 -01 REVISIONS 1E11 MI ■ 7 UNIT HEATER, -fp —1 - -.--UNIT HEATER *'FF STAIRS - H J/ I If DOWN UNIT HEATER "—REMOVE EXISTI UNIT HEATER / ,„///,„ G UNIT HEATER UNIT HEATER LTI REMOVE EXISTING AIR HANDLING UNIT, GAS FLUE AND ALL ASSOCIATED PIPING. (400 1 MBH EACH) • 4—UNIT HEATER Ir- 1 r I 4 — 1 STAIRS\ I I DOWN REMOVE EXISTING 13KW ELECTRIC UNIT HEATER (TYPICAL) REMOVE ISTING SHOWER REMOVE EXISTING BASEBOARD HEATER F .,/ • *I — HEATER UNIT UNIT HEATER HEATER REMOVE EXISTING BASEBOARD TER IrmrIFFI1 I1 i PIIIIIIIII111111111111111111r1 1 ii11111111111111101i11FF priiiiiiiillv 0 CHINA 1 17„. 2 ' 2/a . 5 • 6 Si VI, El EL 1 11....',......01.:, , rt.'.8_ — a _,...:i...i.:. . ii......4 Q b 1 EXISTING GAS METER LOCATION CONSTRUCTION NOTES_ 0 REMOVE EXISTING WATER CLOSET AND ASSOCIATED PIPING. 0 REMOVE EXISTING EXHAUST FAN, ASSOCIATED DUCTWORK & ROOF CAP PATCH ROOF TO MATCH EXISTING. 6 DEMOLITION FLOOR PLAN - OVERALL SCALE' 1/8 = -00 1 oc;\ s oA \ N RECEIVED CITY oFTUKINILA OCT 1 1 7001 AERMINIVAIR WIRES s*/21/41 EUSE OF DOCUMENTS 1. MATERIAL HEREIN CONSTITUTES ME ORI GINAL AND UNPUBLISHED WORK OF THE GINEER AND MAY NOT BE USED DUPLICATED IR DISCLOSED WITHOUT THE 1111ITTEN CONSENT F 111E ENGINEER. COPYRIGHT © 2001 Y BCE ENGINEERS, INC. AU. RIGHTS RESERVED. DRAWN BY: MCE CHECKED BY: . DEO REVISIONS: DRAWING No, M2.1 DATE: 10-09-01 PROJECT No.201-113 Valco Graphics, Inc. 480 Andover Park East Seattle, WA 98188 4ILCO DRAWN BY: HMS CHECKED BY: CAH REVISIONS: DRAWING No. E 2.1 DATE: 10 -9 -01 PROJECT No.201 -113 480V, 30, TO REMAIN '-WIRE 1• F- 1- 1- 1• -1 -4 F -i I- -I -1 i I-- -- I 1 --UNIT HEATER TO BE REMOVED I.J -r i 4- MEZZANINE 4- 1- -1 I- i 4- 1- WIREWAY TO BE REMOVED F i -4 i -4 O - --I I- i F F r -i STAIRS I I I J le DOWN i HEATER TO BE REMOVED h H 4- 1- i 4 - I-- -I 1- i i I �% - � —UNIT HEATER TO BE REMOVED i i i UNIT HEATER TO BE REMOVED F UNIT HEATER TO BE REMOVED F 1- F 1- 4- i i i i i i F I-- --I 1 - PANEL 'M' ABOVE IN MEZZANINE TO BE REMOVED MEZZANINE f F F GAS UNIT HEATER TO BE REMOVED h 1- 1- i i 1- i 1. H - -i F %,5 HEATER TO BE REMOVED 4 - 4 - . 4 4- L i i -4 i i H i i - -& STAIRS v,I 11 If nnw 4,1 4 - 4 - 4 - 4 - - 4 F I - - - --I I- i i -4 -4 1- MEZZANINE O 1- 4- 1_ 1- 1- i I- PANEL 'A3' (16X6X45) HEATER SWITCH PANEL 120/208 TO ;REMAIN - - - -- - -� i -1 — UNIT HEATER TO BE REMOVED 'PENDANT FIXTURE i i HEATER TO BE REMOVED i HEATER TO BE REMO -i H UNIT` HEATER TO BE REMOVED H F PANEL 'P5' TO REMAIN PANEL 'P4' .T0 REMAIN,. C.T. CAN i- 1- 1- i i DATA BACKBOARD TO REMAIN �' Illy ' �'I'I'I'�'I'1111I'I'I'I' I'I' ill' 1111f111��I�I�1' I' i'I' I'jll�i +l���1i11�1,�,111�.f illllllll, O w . a. 3 w. :4 6 CHINA INCH 6 1 :_ '�� i i -0 SPRINKLER RISER FIRE ALARM CONTROL PANEL TO REMAIN MDB -1 277/480V, 30, 4— WIRE,1000A TO REMAIN 15KVA TRANSFORMER 480V 30, 4 —WIRE TO 120/208V 30, 4 —WIRE TO REMAIN NEL —300A F ED SCON 02 REMOVE ALL DEVICES AND CONDUCTORS AND CT CAN. SEE SHEET E5.1 POWER RISER DIAGRAM FOR MORE DETAILS. {� 03 EXTERIOR LIGHT FIXTURE TO REMAIN, CIRCUIT TO BE KEPT 30 IN TACT AND OPERATIONAL. ® EXISTING LIGHT FIXTURE TO BE REUSED IN NEW DOCK, EXTEND EXISTING • CONDUIT AND WIRING TO NEW LOCATION PER LIGHTING PLAN SHEET E3.1. CONSTRUCTION NOTES 0 RELOCATE EXISTING TRANSFORMER TO NEW LOCATION PER SEE SHEET E4.1. SEE SHEET E5.1 POWER RISER DIAGRAM FOR MORE DETAILS. 05 EXISTING EXIT /EMERGENCY LIGHT TO BE RELOCATED. SEE LIGHTING PLAN SHEET E3.1, FOR NEW LOCATION AND CIRCUIT. EXISTING EXIT /EMERGENCY LIGHT TO BE REUSED. CIRCUIT TO BE REVISED PER LIGHTING PLAN SHEET E3.1. 07 EXISTING , RECEPTACLE TO BE REUSED, CIRCUIT TO BE REVISED PER POWER PLAN SHEET E4.1. ® METER BASE TO BE REMOVED, SEE POWER RISER DIAGRAM SHEET E5,1 FOR MORE DETAILS. 0 EXISTING DOOR MOTOR AND CONTROLLERS TO REMAIN, CIRCUIT TO REMAIN THE SAME AND OPERATIONAL. CI ALL DEVICES SHOWN ON THIS AREA OTHER THAN THOSE NOTED TO BE REMAIN SHALL BE REMOVED. PULL , CONDUCTORS AND ANY ELECTRICAL APPURTENANCE. SEE SHEET E2.2 FOR OFFICE & UNDER MEZZANINE DEMOLITION FLOOR PLAN DEMOLITION FLOOR PLAN - OVERALL SCALEI 1/8' = 1' -0' GENERAL NOTES 1. THIS DEMOLITION PLAN HAS NO INTENT TO SHOW ALL ELECTRICAL DEVICES NEEDING TO BE REMOVED. ALL WALLS SHOWN DASHED ARE BEING REMOVED. ELECTRICAL CONTRACTOR SHALL VERIFY DEMOLITION WORK INVOLVED PRIOR TO BID. 2. ALL CONDUIT AND WIRING FOR DEVICES BEING REMOVED SHALL BE REMOVED BACK TO PANEL THAT THE CIRCUITS ORIGINATE FROM. CONTRACTOR MAY REUSE EXISTING CONDUITS FOR ROUTING NEW CIRCUITS. 3. ANY CIRCUITS TO REMAIN WHICH ARE DISTURBE 'BY DEMOLITION SHALL BE INTERCEPTED AND RE— ROUTED TO EXISTING PANEL CIRCUIT. cr y OFw qi OCT 1 1 ?001 PERMI,TeXt0ER I EXPIRES 6/2/03 REUSE OF DOCUMENTS ALL MATERIAL HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ENGINEER AND MAY NOT BE USED. DOPUCATED OR DISCLOSED VATHOUT THE WRITTEN CONSENT OF THE ENGINEER. COPYRIGHT © 2001 BY BCE ENGINEERS, INC. ALL RIGHTS RESERVED. E21_201-113.dwg Dote/lime: October 08, 2001 2:19 p.m. Scale: 1=96 HENRYS Xrefs: t. ■ Arent !1 uI:iuIr:.uuriIimlil 1 "l11111111M1111111 111U 111 tt tt it >It IIIM111111 , Ili1111IiRe1II 6 1 � �' 11 11 11 Ii 111111111i �.?.111111tiI111tt11 ,t1.u,t11i mug' 111111E11111111111111111111 ��t_ 111111111 MIMI 1111111111111M1111111111 1mmill it liamula 'r �t grim �. �� It 1111 � IIi i ill 1 in �,i� 1111 1 11110 111� 1 0 ii ° II I 44 it Il" ' 1 ' ®III rj ;i � ' -►�' i fir' Emil d 1 1 1 -U1 - •IIIIIRI 21111 ®1 . ®� �� 1 NMI EXISTING DATA /TELEPHONE TO REMAIN. 05 ALL DEVICES SHOWN IN THIS AREA 1OTHER THAN THOSE NOTED TO REMAIN SHALL BE REMOVED. PULL CONDUCTORS AND ANY ELECTRICAL APPURTENANCE. . ®_ ) ('(1111TrIr',1,1111(111I1111' 10:11'1' 111 11 I•, "' (rll 0 CHINA 1 • b Gr t o �4. ¢ 6 CL bL EL 7.l L R n +48" CONSTRUCTION NOTES 0 EXISTING LIGHT FIXTURE TO BE REPLACED WITH NEW, PER LIGHTING PLAN SHEET E3,2. CONTRACTOR TO REUSE EXISTING CONDUIT AND WIRING AS MUCH AS POSSIBLE, EXTEND NEW CIRCUIT AS REQUIRED. 0 EXISTING LIGHT SWITCH TO BE REUSED, REPLACE AS DIRECTED ON SHEET E3.2. 0 EXISTING RECEPTACLE TO : REMAIN, CIRCUIT TO BE KEPT INTACT SAME AND OPERATIONAL. DEMOLITION FLOOR PLAN OFFICE & UNDER MEZZANINE GENERAL NOTES 1. THIS DEMOLITION PLAN HAS NO INTENT TO SHOW ALL ELECTRICAL DEVICES NEEDING TO BE REMOVED. ALL WALLS SHOWN DASHED ARE BEING REMOVED. ELECTRICAL CONTRACTOR SHALL VERIFY DEMOLITION WORK INVOLVED PRIOR TO BID. 2. ALL CONDUIT AND WIRING FOR DEVICES BEING REMOVED' SHALL BE REMOVED BACK TO PANEL THAT THE CIRCUITS ORIGINATE FROM. CONTRACTOR MAY REUSE EXISTING CONDUITS FOR ROUTING NEW CIRCUITS. 3:,;ANY CIRCUITS TO REMAIN WHICH. ARE DISTURBED BY DEMOLITION SHALL BE INTER D AND RE- ROUTED TO EXISTING 141 UIT. X01 SCALEI 1/8' = 1' -0' \_ �'. O RECEIVED 0 C 1 1 2001 PERMIT CENTER REUSE OF DOCUMENTS ALL MATERIAL HEREIN CONSTITUTES THE ORIGINAL AND UNPUBUSHED WORK OF THE ENGINEER AND MAY NOT BE USED, DUPLICATED OR DISCLOSED MITHOUT THE NRITTEN CONSENT OF THE ENGINEER. COPYRIGHT' © 2001 BY BCE ENGINEERS, INC. AU. RIGHTS RESERVED. DRAWN BY: HMS C,,HECKED BY CAH REVISIONS: DRAWING No. E2. DATE: 10 -9 -01 PROJECT No.201 -113