Loading...
HomeMy WebLinkAboutPermit 5965 - China Coin Restaurant - Walls DemolitionAPPROVED FOR / , / BUILDING ISSUANCE BY: L�'( , OFFICIAL DATE: � 3 -;7v -- 9 U I hereby certify that I have read a xamined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or perf.rmance or work. I am authorized to sign for and obtain this building permit. a ' / ATUR : _ - ' -'. r�/-cx-1 S IGN f` "'� - i - DATE .3 / l /6) v PRINT NAME: 2 fr /c , � /1 f COMPA / Co,/f o //I I /r 4) �'I . 1 PROPERTY OWNER Real Properties PHONE ADDRESS 111 Californina Avenue, Suite 2525, San Francisco, CA ZIP 94111 CONTRACTOR Teh Construction PHONE 329 -9072 ADDRESS 3103 Eastlake Avenue East, Seattle, WA ZIP 98102 WA. ST. CONTRACTOR'S LICENSE # TEHCO * *153K9 EXP DATE 5 - 16 - 90 ARCHITECT PHONE ADDRESS ZIP TYPE OF CONSTRUCTION: Demo UBC EDITION (year) 8r SETBACKS: N - S - E - W - FIRE PROTECTION: ❑S • rinklers ❑ Detectors ®N /A UTI LITY PERMITS REQUIRED ?❑ Yes ®N No (thro Pub lic Works) ZONING: BAR /LAND USE CONDITIONS ❑ Yes Go No CONDITIONS (other than those noted on or attached to permit/plans): FLOOR W SQUARE FEET ..__- SQUARE FEET USE -4 I / CODE COMPLIANCE / I / FLOOR W SQUARE FEET CC O. LOAD SQUARE FEET OCC. LOAD SQUARE FEET CCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD TOTAL CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 BUILDING S C ) (PERMIT NO. � DATE ISSUED: 72-01 --'1 o BUILDI!G PERMIT (POST WITH INSPEL f ION CARD AND PLANS IN A CONSPICUOUS LOCATION) FEES DESCRIPTION BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE ENERGY SURCHARGE OTHER: TOTAL - AMOUNT RCPT IM 15.00 4.50 19.50 6783 6783 DATE 3 -19 -90 3 -19 -90 :k ._C ;90 -130 PROJECT INFORMATION 16860 uthcenter Pv • oe So 350_00 AB 81 PROJECT NAME/TENANT China Coin Restaurant A 5 QR C UNT#t 262304 -9129 TYPE OF U New Building Addition Tenant Improvement (commercial) ` Demolition (building) ❑ Grading/Fill WORK: ❑ Rack Storage ❑ Reroof ❑ Remodel (residential) ® Other: Interior Demolition DESCRIBE WORK TO BE DONE: Demolition of non - structural interior walls. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period Gf 180 days from the last inspection. CERTIFICATE OF I DATE ISSUED: OCCUPANCY NO. PROPERTY OWNER Real Properties PHONE ADDRESS 111 Californina Avenue, Suite 2525, San Francisco, CA PHONE 329 EXP DATE PHONE ZIP 9111 -9072 ZIP 98102 5 -16 -90 CONTRACTOR Teh Construction ADDRESS 3103 Eastlake Avenue East, Seattle, WA WA. ST. CONTRACTOR'S LICENSE # TEHCO * *153K9 ARCHITECT ADDRESS ZIP 0 SC ' IP ON MO N CPT 0 DAT BUILDING PERMIT FEE 15.00 6783 3 -12 -90 PLAN CHECK FEE BUILDING SURCHARGE 4,50 6783 3 -19 -90 ENERGY SURCHARGE OCC. • ' SQUARE OCC. OTHER: OCC. • . I TOTAL w .. AR F TOTAL OCC. LOAD TOTAL -____12, 50 ;a 3 ' Iv USE .4 I / CODE; COMPLIANCE / e / ;; . / b ; , CONDITIONS (other than those noted on or attached to permiVplans): FLOOR SQUARE 4 OCC. ■ • 0 SQUARE - 3 OCC. s- ;QUAKE OCC. • ' SQUARE OCC. SQUARE OCC. • . I TOTAL w .. AR F TOTAL OCC. LOAD • 441 ;a 3 TOTAL TYPE OF CONSTRUCTION: UBC EDITION (year) ,. Demo 8� SETBACKS: N— S— E — UTILITY PERMITS REQUIRED ?❑Yes ® N o W — hrough ( PubIj Workst FIRE PROTECTION:❑ Sprinklers ❑ Detectors ® N/A ZONING: BAR/LAND USE CONDITIONS❑Yes C No PRINT NAME: ��V /c o!' ; ,s COMPANY: r_�.l C l CONDITIONS (other than those noted on or attached to permiVplans): APPHOVED FOR l / . BUILDING ISSUANCE BY: CC '' .....e—...i.,....4 OFFICIAL DATE: � - 2 3 ` ) U I hereby certify that I have read a dicamined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or A e perfrmance or work. I am authorized to sign for and obtain this building permit. SIGNATUR . 41 , ;" •- - n4- -0. - DATE: 3/7? / A 0 PRINT NAME: ��V /c o!' ; ,s COMPANY: r_�.l C l 4. CITY OF TUKWILA Departrppnt of Community Development - Building Division . 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 BUILDING PERMIT NO. 59 (f)S DATE ISSUED: SI AD I RES PROJECT NAME/TENANT China Coin Restaurant CERTIFICATE OF OCCUPANCY NO. 16860 Southcenter Py nt UILDII G PERMIT J (POST WITH INSPL_ i ION CARD AND PLANS IN A CONSPICUOUS LOCATION) PROJECT INFORMATION SUI H ECK 9 0 -130 VA U 0 R FEES N CTION 350.00 UNTN 262304 -9129 TYPE OF U New Building Addition Tenant Improvement (commercial) • Demolition (building)-0 Grading/Fill WORK: ❑ Rack Storage ❑ Reroof ❑ Remodel (residential) ® Other: Interior Demolition DESCRIBE WORK TO BE DONE: Demolition of non - structural interior walls. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DATE ISSUED: Tncnartnr CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188' (206) 433 -1849 Inspection Results /Comments i Date � - '30 - �jp Type of Inspection r T) 2 r(lc ante 1 =1 Or) Date Wanted 5-1 Site Address I pD Sol WAcQnl I Project co C_h i k, C c n Requestor �C� -2--- C-O Phone # Special Instructions • z8x• ur: �a3f' 7, t�.^ a:si°t�r�N�C59A.s!.'tti:etiSiY;.1 :5:F:k .,v y ! ;i":: + * rv MgVAiu INSPECN RECORD PERMIT #cJ10_5 na.p P■ftr 10: tic a.m. p.m. "X" REQUIRED INSPECTIONS PHONE AP DATE PROVED INSPECT. INITIALS DATES) CORRECTION NOTICE ISSUED 1 Footings 433 -1849 2 Foundation 433 -1849 3 Slab and/or Slab Insulation 433 -1849 4 Shear Wall Nailing 433 -1849 5 Roof Sheathing Nailing 433 -1849 6 Masonry Chimney 433 -1849 7 Framing 433 -1849 8 Insulation 433 -1849 9 Suspended Ceiling 433 -1849 10 Wall Board Fastening 433 -1849 11 12 13 14 FIRE FINAL Insp: 575 -4404 15 PLANNING FINAL 433-1849 16 PUBLIC WORKS FINAL 433 -0179 x 17 BUILDING FINAL 433 -1849 CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 SITE ADDRESS: OTHER AGENCIES: BUILD1G PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) SUITE NO.: BUILDING PERMIT NO. DATE ISSUED: PROJECT: Sc3 16860 Southcenter Py China Coin Restaurant CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are sot and rebar is tied in place. 2. FOUNDATION - When forms and robar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. Plumbing (including gas piping) — King County Health Department -- 296 -4732 Electrical — Washington State Department of Labor and Industries — 872 -6363 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 433 -1849. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 64/28/00 PERMIT NO. • CONTACTED DATE NOTIFIED ,J)ckv id Johnson _ BY: "' q� (Init.) � DATE READY PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING 93 3RD NOTIFICATION BY: (init.) S REVIEW COMPLETED fr BUILDING PERMIT APPLICATION TRACKING PROJECT NAME Chi nrte., (oi SITE ADDRESS I (D o O 33tY hLprer SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCCU- PANCY LOAD DEPARTMENTAL REVIEW "X" in box Indicates which departments need to review the project. ::AR.T.._._._.. O PLANNING O PUBLIC WORKS O OTHER ® BUILDING - final review RO O FIRE Ci BUILDING - 3 2 o c1 c� initial review 3- I� - 9 ° ROU ED) INIT: INIT: INIT: INIT: .f)/ U REM NTS / COMME CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: fl Sprinklers ( ]Detectors (X) N/A FIRE DEPT. LETTER DATED: INSPECTOR: ZONING: IBAR4.AND USE CONDITIONS? (Yes 111Q No REFERENCE FILE NOS.: MINIMUM SETBACKS: N- S- E- W- UTILITY PERMITS REQUIRED? ( Yes 1><1 No PUBLIC WORKS LETTER DATED: TYPE OF CONSTRUCTION: UBC EDITION (year): VLVV VVNI„L/V „IQ, LJVL„VVQ,V, IYf.. Ina .•i1 ✓VIL/v (206) 433 -1849 I Ii irT. �#- �a:Ti Q�'T'TIil ►iif•f �7�i� " �+ 1 1 1 11411111111111G. . OD PSIMULIBM l'OSE APPLICATION MUST DL FILLED OUT COMPLETELY PLAN CHECK FEE �� ENERGY SURCHARGE •THER: TOTAL - 111111=11111111 ___ 1111MIP ®��® 11110111�1i— SITE ADDRESS ( . / � / SUITE # R >� U �t' () 7 D 07 � 11(� - ; �r l � r K l u', VALUE OF CONSTRUCTION - $ ,� j S a PROJECT NAME/TENANT , `' /7.4i,-1, (: -n i,2 1 - e , 5 1 , f a r / ASSESSOR ACCOUNT c is 30(-1 # - c ~ ) as i ci I Q q , X113`) TYPE OF Li New Building U Addition Tenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) C Other - ttr tot :J :)Qrno DESCRIBE WORK TO BE DONE: 9 F.. rr,.,/ 7 l a, 0 ,_ /vaA/- •.S>4 C7 f l /4 794 ri op / --a / BUILDING USE (office, warehouse, etc.) ( 71.; l r 1 f . ) NATURE OF BUSINESS: y� T � ` WILL THERE BE A CHANG IN US U No LI Yes IF YES, EXPLAIN: j _,l,: r. -(A / f , /4 57 t4 pn i SQUARE FOOTAGE - Building: Tenant Space:,25;2 ; , s c Area of Construction: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 3-No 0 Yes IF YES, EXPLAIN: -P f v.5 W - 'C PROPERTY OWNER�a );(4 Y - � s /v7 1 C / -- I 'HONE ADDRESS .. � " , `� z-,9 / / / / . .9 r41r-, d e 14: r, K; ;.r• a .�G !'�✓I G _� G ZIP - 'CONTRACTOR -� /.,,,.5 1ri, PHONE 3 (76 ADDRESS 6 �i /.Q (N, 1 ✓�b ..--3 Ii�S�c, ,gyp /V G'S° � -� WA. ST. CONTRACTOR'S LICENSE # ... -,-- a xi , . /5 L /\• EXP. DATE 5 0 ARCHITECT PHONE ADDRESS ZIP CITY OF TUKWILA 'Department of Community Development - Building Division BUILDItT PERMIT APPLICATION FEES (for staff use only) I HEREBY CERTIFY Itiat I HAVE READ AND EXAMINED THIS ;TRUE: AND CORRECT, AND l AM AU T APPLY FO R. BUILDIN SIGNATUR ��)_C�� / -i'l6 --r."- - AUTHORIZED PRINT NAME / -- •j , -7 s.ein AGENT i / r' X103 t _'S > , De (.� ADDRESS DATE 3 41'40 PHONE ., 2q — 9 ' a7 2 CITY /ZIP��u, fn CONTACT PERSON � -�/ PHONE 3-9—q.6 >� APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of community n?tielopmpnt prior to application submittal. Contact the Permit Coord'.natcr at 133 - 1851 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 433 -1849. DATE APPLICATION ACCEPTED I DATE APPLICATION EXPIRES 3 I� 90 I 9-19-90 SliJMITTAL CHECaIST JllK- 1 1 -90 T E R CONSTRUCTIO general contractor's number: TELEPHONE: 329 -9072 3103 Eastlake Ave. E. Seattle, WA 98102 TO : /4K. K/ INlL Soq/ FAX : 43 .. 3 666 PHONE:. 41/ 3 6 7 FROM : ANDY TEH TEH CONSTRUCTION CO. FAX : 328 -5372 PHONE: 329 -9072 RE: CH /A/A CoMJ RSSP-(>/QAIV T 'CH4A/4 PAGE : 1 OF 1 Y` f�2iK' �' � �n �J�yt; sv� rc�Fn' t' xarc m �• a. t.« •.�,�,+nr+,',nr�,urA�3�i5..�y�x tY'�' G ita, f,,. W.«:� .wr�,� sF;,w. ta:�EU�• rt .v.. r'.�c, cra;.... 4 MON 1 t.t. 20 COMPANY tehco * *153k9 FAX: 328 -5372 RESTAURANT & COMMERCIAL DESIGN and CONSTRUCTION JUN 1 1 1990 CITY l"7- TZ PLANNING DE rRo T ° -13/ P . 0 1 )INING AREA SHIER uNTER OFFICE r 44' MINI. TYP. .. .. .> .. .. .. .(. ; [ CHANGE #1 60 NO DDOOR f 9' -8' _ DINING AREA CHANGE PLAN 1 I 1 1 i, 48' 4 J # RELOCATE THIS WALL MOVE #4 RELOCATE THIS DOOR 0 4'X 6' BOOTH TYP. 44' MINI. TYP. FAX : PHONE: PAGE : 1 OF 1 JUN— 1 1 —90 MON s 20 TELEPHONE: 329 -9072 3103 Eastlake Ave. E. Seattle, WA 98102 TO : MK. KEA/ JV/LSo,V 431-'&66t" it 367o FROM : ANDY TEH TER CONSTRUCTION CO. FAX : 328 -5372 PHONE: 329 -9072 RE: `H'Ni Com/ E 7 -L) ,4N7' GHA -A/jrs ; „_ T E E CONSTRUCTION general contractor's number: C O M P A N Y tebco * *153k9 P . 0 1 FAX: 328 -5372 RESTAURANT & COMMERCIAL DESIGN and CONSTRUCTION -] JUN 11 CITY (; Y PL -- NNN NG DEPT. l rrr D ?6S r'RoarGT o -/at )INING AREA SHIER UNTER OFFICE 44' MINI. TYP. 9' -8' 1' CHANGE #1 RD NO DDOOR Nf DINING AREA CHANGE PLAN 48' # RELOCATE THIS WALL 3 MOVE TABL AND CHAIRS 4'X 6' BOOTH TYP. ICE (UNDER) # RELOCATE THIS DOOR 44' MINI. TYP. a REIEIM FINISH SCHEDULE NO I FLOOR BASE WALL CEILING REMARK ELECTRICAL MAT. FIN MAT. FIN EQUIPMENT AND FURNITURE SCHEDULE FIN MAT. FIN COUNTER, SERVICE OFFICE CARPET 'G CO] RUB EXIST, GWB EN SUSP, EXIST. r ,.. it i iolatiQ of any ,.,. .;;.a,.c l?t of contractor's '"71`x$ ,✓ 1 G . .14.5 PREP. AREA 1 PAGE 1 OF 2 r c REIEIM FINISH SCHEDULE NO NAME FLOOR BASE WALL CEILING REMARK ELECTRICAL MAT. FIN MAT. FIN MAT, FIN MAT. FIN COUNTER, SERVICE OFFICE CARPET RUB EXIST, GWB EN SUSP, EXIST. BAR--SINK PREP. AREA Q -TILE SEAL RUB GWB EN GWB EN COFFEE MAKER STORAGE ROOM VINYL RUB GWB EN GWB EN ICE MAKER KITCHEN Q -TILE SEAL RUB GWTD EN GWB EN SHELF REST ROOM VINYL RUB I GWB EN GWB EN C. TILE 5' HIGH DISH VASH Q - TILE VINYL EN RUB RUB GWB GWB EN EN GWB GWB EN EN S/S TABLE HALL AT R. ROOM ENTRY AREA C - TILE SEAL RU B GWB EXIST, SUSP, EXIST, SEE DETAIL £DRAWING WAITING C - TILE SEAL RUB Gy,/I3 EXIST. SUSP, EXIST. DINING CARPET EXIST. RUB EXIST. GWB EXIST. SUSP. EXIST. CASHIER C -TILE SEAL RUB G \./B EN SUSP, EXIST, DISH WASHER SERVICE C - TILE SEAL RUB GWB EN GWB EN S/S CLEAN DISH TABLE 13 S/S DISH SHELF 14 REF. SALAD TABLE 15 S/S WORK TABLE 16 S/S DISH RACK PROJECT DATA ADDRESS: ITEM : # LEGAL DESCRIPTION DESCRIPTION OCCUPANCY t A3 CONSTRUCTION TYPE I.II- 1HR. TOTAL. SQUARE FOOTAGE E BUILDING F TOTAL SQUARE FOOTAGE 1 PROJECT i TOTAL NUMBER OF CUSTOMER SEATING TOTAL NUMBER OF EMPLOYEES t 4 DINING AREA SQUARE FOOTAGE BAR/ LOUNGE AREA SQUARE FOOTAGE N/A KITCHEN AREA SQUARE FOOTAGE t • ,.M: OFFICE ICE (UNDER) 10 11 12 13 (HOOD) _ r 4' REF. 4> SALAD 5' WORK TABLE 6' STEAM TABLE 12' CHINESE WOK RANGE 12' OVE EAD SHELF HALLWAY 44 37 PREP -AREA WORK TABLE 89 • LEGEND • -- 89' �-- — -- = NEW WALL 3' -10' • 2'X 2' TABLE TYP : ' : • ..WAITING 8, - OVERHEAD SHELVES = WALL TO BE DEMOLISHED = EXISTING WALL • = FLOOR TILE \ DINING AREA CASHIER COUNTER 45' 4'X 6' BOOTH L TYP. 9'-8' t 42` -8" • 44' MINI. TYP, i , 44' MINI. TYP, 4 �I <\>/ /\\-/> /\ 53 3' )T 3' TABLE \ / TYP. 68' -6" 28' J _'' 54 DINING AREA FL 4'X E BOOTH TYP> SCALE! 1/4' = 1 44' MINI. I TYP. 4' 28' 32' !, 3' 10'- 25' -10" LAH NO SCALE �illjll►'► Iillli( IIIIIl1' 111111ililililll 'IIIli1'Il1lllllll11ll1IIIIIIl1 iIi Ill'Il11Il1'illIII i i `lilil'II�IIlI'Ililiii'ili�II'I It1IIIIII IIIIIII�IIIIIIIIl IIu h 1111 111111111111 II Il 0 2 5 6 7 8 9 1(1 11 M4GEfNGfHUANr 1� 71 NOT' =: If the microfilmed eocumcnt is less clear then this notice, it Is Cue to the quality cr the orieinel c'ocumcnt. „..- - . .... _... .__.__ _- .- _......_ . __._._ . _._...o o t» F3c: Le 99e GZ +7Z EZ Ze LG Qe bl BL LA 91 GI. *7L £L ZL It 01, 6 B L. 9 c,; +7 C Z L w,v Q IIIIIIW IIIII JIMIIHII I 1I III Inl lul l IIII II IIH IH l l lllliIIlll 1141111 MIIIHIl s lfilnlllriilfinlWIlliillIllklllin ikillnillIII1I1INIII NI111IlIIHIIIIJIIIIInnInIIIIII 1I h11111I1I1111{111111n lifili l li I Ill I I I 1 ._ _ ,/ i n II _ Ill�iiili illlli��ILIil1Ili�Lill 1 :6,- ,ii,lllll�i1i11i1111 • .:,.. : .;•�. .,. ,.. ✓: 7N /..! / 2. ,',.; . . ,3 i / ! i'� fTI. i ^'n r".: ': `l .1 Ii. 0 Z 36' KEY PLAN 6' 4'- SOUTHCENTER PARKWAY 7'-6" I understand that r,e 3U: i +_d to errors SITE M n ans does t; adopted code or copy of approver CITY OF TUKWILA APPROVED IP. "01990 AS.9TtD BUILDING DIVISI F3UILD 34' -8" Tyr....‘62•• Permit No RECEIVED CITY OF Tl;KWII.A MAR 1 9 1990 PERMIT CENTER •. N s. (o,' -J 00 Y EQUIPMENT AND FURNITURE SCHEDULE ITEM : # ITEM NAME DESCRIPTION DIMENSION (L) X (V) X (H) POWER SOURCE PLUMBING ELECTRICAL GAS PHASE VOLT AMP BTU PIPE COUNTER, SERVICE PLY, FORMICA TOP D BAR--SINK I L ✓ COFFEE MAKER '. D ICE MAKER UNDER COUNTER D SHELF PLY, FORMICA TOP D COUNTER /SHELF PLY. FORMICA TOP . D S/S TABLE D S/S DISH RACK D PRE -RINSE SINK ZO GARBAGE DISPOSER 11 DISH WASHER ^I S/S CLEAN DISH TABLE 13 S/S DISH SHELF 14 REF. SALAD TABLE 15 S/S WORK TABLE 16 S/S DISH RACK I 17 HEAT LAMP 18 STEAM TABLE 6' 19 EXHAUST HOOD I 20 AIR SHAFT 21 EXHAUST FAN J 22 D MAKE -UP AIR ` I 23 AIR -COND /HEAT a . . 24 FIRE SPRINKLERS CHINESE WOK RANGE USED 12' 126 2- BURNER RANGE W/ GRILL /OVEN D 27 GRILL W/ OVEN /RANGE FRYER 16' 29 SHELF PLY, FORMICA TtIP 30 HAND -SINK � - I 1 31 SHELF 32 S/S WORK TABLE 33 SHELVES I PLY. FORMICA TOP 34 2 -COMP SINK 35 GARBAGE DISPOSER J X 36 MOP -SINK J T 37 CLASS 'B' HOOD I 3 E3 OVEN 24' 39 S/S TABLE 40 WALK -IN COOLER • 41 _WALK-IN FREEZER 1 � T I f 4 e ' SHELVES PLY. FORMICA TOP 43 SHELVES PLY. FORMICA TOP , 44 S/S TABLE - I, ` 45 SI- IELVES PLY. FORMICA TOP I l . 46 S/S TABLE - R SHELVES ' PLY. FORMICA TOP , 49 E I L BOOTH i 4' x 6' BOOTH 89' X 89' i PLY. FORMICA TOP 3' X 3' 6' PLY. FORMICA TOP 54 TABLE, ROUND TABLE, ROUND 5 _9 1 TABLE PLY. FORMICA TOP 5' PLY. F'ORMIGA TOP 2' X 2' - - - -. � 57 CHAIR :58� PLANTTER BOX c PLY. FORMICA 59 4 TER BOX OR, FISH TANK I PLANTTER BOX l I i 61 T PLY. FORMICA TOP I BENCH L NOTE: ALL FOOD COOKING AND PREPARATION EQUIPMENT SHALL BE 'NSF' APPROVED AND LABLED ALL HAND SINK AND RESTROOM SINKS SHALL PROVIDE SOAP, PAPER TOWEL DISPENSER NO EXPOSED PLUMBING IN ANY FOOD PREPARATION AREA ALL FURNITURE (TABLES, SHELVES, ETC,) SHALL BE °NSF° APPROVED OR WASHABLE, WALLS IN FiJL'D PREPARATION AREA SHALL BE FINISHED WITH WASHABLE MATERIAL • ,.M: OFFICE ICE (UNDER) 10 11 12 13 (HOOD) _ r 4' REF. 4> SALAD 5' WORK TABLE 6' STEAM TABLE 12' CHINESE WOK RANGE 12' OVE EAD SHELF HALLWAY 44 37 PREP -AREA WORK TABLE 89 • LEGEND • -- 89' �-- — -- = NEW WALL 3' -10' • 2'X 2' TABLE TYP : ' : • ..WAITING 8, - OVERHEAD SHELVES = WALL TO BE DEMOLISHED = EXISTING WALL • = FLOOR TILE \ DINING AREA CASHIER COUNTER 45' 4'X 6' BOOTH L TYP. 9'-8' t 42` -8" • 44' MINI. TYP, i , 44' MINI. TYP, 4 �I <\>/ /\\-/> /\ 53 3' )T 3' TABLE \ / TYP. 68' -6" 28' J _'' 54 DINING AREA FL 4'X E BOOTH TYP> SCALE! 1/4' = 1 44' MINI. I TYP. 4' 28' 32' !, 3' 10'- 25' -10" LAH NO SCALE �illjll►'► Iillli( IIIIIl1' 111111ililililll 'IIIli1'Il1lllllll11ll1IIIIIIl1 iIi Ill'Il11Il1'illIII i i `lilil'II�IIlI'Ililiii'ili�II'I It1IIIIII IIIIIII�IIIIIIIIl IIu h 1111 111111111111 II Il 0 2 5 6 7 8 9 1(1 11 M4GEfNGfHUANr 1� 71 NOT' =: If the microfilmed eocumcnt is less clear then this notice, it Is Cue to the quality cr the orieinel c'ocumcnt. „..- - . .... _... .__.__ _- .- _......_ . __._._ . _._...o o t» F3c: Le 99e GZ +7Z EZ Ze LG Qe bl BL LA 91 GI. *7L £L ZL It 01, 6 B L. 9 c,; +7 C Z L w,v Q IIIIIIW IIIII JIMIIHII I 1I III Inl lul l IIII II IIH IH l l lllliIIlll 1141111 MIIIHIl s lfilnlllriilfinlWIlliillIllklllin ikillnillIII1I1INIII NI111IlIIHIIIIJIIIIInnInIIIIII 1I h11111I1I1111{111111n lifili l li I Ill I I I 1 ._ _ ,/ i n II _ Ill�iiili illlli��ILIil1Ili�Lill 1 :6,- ,ii,lllll�i1i11i1111 • .:,.. : .;•�. .,. ,.. ✓: 7N /..! / 2. ,',.; . . ,3 i / ! i'� fTI. i ^'n r".: ': `l .1 Ii. 0 Z 36' KEY PLAN 6' 4'- SOUTHCENTER PARKWAY 7'-6" I understand that r,e 3U: i +_d to errors SITE M n ans does t; adopted code or copy of approver CITY OF TUKWILA APPROVED IP. "01990 AS.9TtD BUILDING DIVISI F3UILD 34' -8" Tyr....‘62•• Permit No RECEIVED CITY OF Tl;KWII.A MAR 1 9 1990 PERMIT CENTER •. N s. (o,' -J 00 Y 0 DODD FLUORESCENT LIGHT 2'( 4' BOXED FLUORESCENT LIGHT WALL OUTLET (NUMBER = DIST, TO FL,) (DWING ROOM) E1 BJ fi- Di WE DEDICATED WALL OUTLET JUNCTION BOX - DIRECT CONNECT SWITCH W/ DIMMER F'AN -LIGHT COM, NIGHT LIGHT WALL MOUNT LIGHT RECESSED CEIL. CAN - 75W EXIST, CEIL. � GAS LINE LEx] I LEGEND BLOCKING - 5/8' TYPE 'X' GWB �-- 2X4 STUDS EXIST, SLAB TYP . WALL SECTION TOP CAP TREATED 2X4 CONCRETE FLOOR CUT OPEN, 12' WIDE COLD & HOT WATER LINE FLOOR SINK, INDIRECT FLOOR DRAIN COLD & HOT WATER FLOOR DRAIN, DIRECT GARBAGE DISPOSAL, DIRECT DRAIN COLD WATER ONLY DIRECT DRAIN INDIRECT DRAIN INTERCOMM P. A. SYSTEM TELEPHONE OUTLET SPRINKLER HEAD 220 V. OUTLET FLOOR OUTLET EXIT SIGN AC / DC BACK -UP EXIT LIGHT AC / DC BACK -UP SPEAKER WALL SWITCH SMOKE DETECTOR MOVE EXIST. DR TO THIS LOCATION SEAL EXIST. DOOR W/ GLASS TO MATCH EXIST. WINDOW & FRAM 6' -0' LOD X 3 It, 3 z I-- w U x I- 1 W C\ u MO. THIS WALL 3' -4' (H) WAILL, COVERED W 5/8' TYPE 'X' 4 4' -8' 32' DR. DINING AREA OFFICE TABLE OFFICE e ` o DINING AREA 42' -8# TYP. WALL BUILT TO CEIL. 32' DR. C- 4'-0' 9' -0' 7 2' -6' 4 TRACK LIGHTING W/ 75W FIXTURES 3' -6 NOTE' EXIST, SPRINKLER SYS. NO CHANGE IN DINING AREA 7' -6' tL I mo ih Ce Z I L CCA OH z J0 3 TRACK LIGHTING W/ 75W FIXTURES TRACK LIGHTING W/ 75W FIXTURES NOTES EXIST, SPRINKLER SYS. NO CHANGE IN DINING AREA ELECTRICAL LAYOUT 11'-8' 6' -O' (H) WAILL, COVERED W/ 5/8' TYPE 'X' GWB FRAMING AND PLUMBING PLAN 20' EXIST. DROP SEAL THIS WINDOW DIMMER SWITCHS FOR TRACK LIGHTING NUMBER OF SWITCH TO BE VERIFIED II I1 EXIST, DROP CEILII -) 8' -0 ' I'EXIST, GWB I ICEILING TRACK LIGHTING W/ 75W FIXTURES 1 1 - _ 1 2 N 28' CEILING 4 r cE 4' , 28' I EXIST. GWB EILING 3' DR. I 2 -WAY SW W/ LOOK - THROUGH WINDOW EXIST. DROP CEIL' i I 1 E XIS1 ' , GviB 2 10'- WE 0, O Co) i 25'- -10' 32' LITE /FAN CONTROLED BY PANEL Cl 3' DR. (FIRE DR.) - 7 - • AIR -CON HEATING ��. ' . � 3' DR. (FIRE DR.) 5' -0' WATER HEAT. (ON CEILING) 3' DR. (FIRE DR.) • • • • W- HEATER ABOVE 23' -6' 5-6' 4 METAL STUD WALL rso 20' EXIST, ELE. PANEL ATTIC ACCESS 22' X 30' f i 24' L J (_ohl IT' 2SE l�J t.:ti �IIIIIIIiI!IIII!lili lill {111111111 I l I l f l l l l I I I l I { II I 11� (!1 II I Ih) l`' 1I 1 1 {II I I { i � I I I 1 1 1 �,,.,N.. 0 2 I{ IIIIIII {II1111I{I III I II' Ill{ IIIIIIi{IIIIIII{III(III{lllllll { {1111 111{ illllll {II1I111{1111111!I1II111{IIII 5 6 7 > 3 g n 11 MAnE R7 GFRMAN! 12 NOT =: if the microfilmed cocument is less cleer then this notice, it is Cue to the quality cr the oripinel c'ocunnent. ee ?L lC ()G E)t 9t Gt 91 at ht Cl et tt ()[ 6 9 L 9 9 10 Iii!!IIIIIIIII!IIIIIIiI ► {11111 !111'1 111 ►111!11! Ili ►I��IIIIIIIIi!Ililll!II {IIIII 1111{ ►11111!11 {IIIIIIiIi {I{il� ! 'w hilI IIilI { ►III�IIlI {ill! 1111! {Ilil�lill {11►IIIIIIII111= 1111! illllllll {IIIilllll�lllllll {I�IIIII!II! r /// .s// "Jr / ri • 6' 4' -0' 24' X 3' DR. (FIRE DR.) EXIST. 7'-6" S ,_ 0 . 7' - -6' 5' -0 CITY OF TUKWj[EA APPROVED 20 Cr? i BU LOING DIVIS CITY Of TUK N I MAR 19 1990 PERMIT CENTER C\2 0 -44‘