HomeMy WebLinkAboutPermit 6246 - Bon Marche - Home Center - ReroofTrammell Crow PHONE 575 -8090 ADDRESS 17900 Southcenter Parkway, Tukwila, WA ZIP 98188 CONTRACTOR Custom Roof in: PHONE 762 -0171 ADDRESS 8001 Fifth Avenue South, Seattle, WA P 98108 WA. ST. CONTRACTOR'S LICENSE # CUSTOR *291M9 EXP DATE 9 -30 -90 ARCHITECT Hodges & Associates PHON € i4- 387 -1000 ADDRESS 1362 Omega, Dallas, TX ZIP' USE c O[)I- c'OLII'I InrIc•t FLOOR SQUARE FEET OCC. LOAD SQUARE FEET OW. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC, LOAD r, i 1 TOTAL TYPE OF CONST. UBC EDITION (year) 1988 SETBACKS: N - S - E - W (through public Works FIRE PROTECTION: ❑ Sprinklers ❑ Detectors Q N/A U TI L ITY P ERMITS REQUIRED? ❑ Yes p No ZONING: BAR /LAND USE CONDITIONS? ❑ Yes X❑ No CONDITIONS (other than those noted on or attached to permit/plans) See attathed Reroof Conditions. n n CITY OF TUKWILA Dept. of Community Development- Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT NO. La 24 DATE ISSUED: 9 _ 2'7 .--9 o SI APPROVED FOR ISSUANCE BY: I CERTIFICATE OF OCCUPANCY NO. Tear off old roof to plywood and reroof. NJ/A BUILDILIG PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) ;1 EmmuL9:11;AiNkl. BUILDING PERMIT.FEE; : PLAN CHECK FEE BUILDING SURCHARGE' • I I I .. FlifIN•1 :: AssubjEl ti am-sfa OMEN 234.00 THER: mite s t: igL.tiori TOTAL - ,234.00 :41.2 50:: I PLAN CHECK NO.: 90 -400 23,000.00 17750 Southcenter Py PROJECT NAME/TENANT Bon Marche Home Center ASSESSOR ACCOUNT # 352304 - 9005 -04 TYPE OF U New Building U Addition U Tenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: ❑ Rack Storage ❑X Reroof ❑ Remodel (residential) ❑ Other: DESCRIBE WORK TO BE DONE: .�i I hereby certify that I have read and :xamined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. BUILDING OFFICIAL SIGNATURE: 22j t ' DATE: /1 //e PRINT NAME: 7-27,7.61 /9, 11/ h-e COMPANY: 44,i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DATE ISSUED: DATE: U /MY w PERMIT NO. <::<::��:. Y;.l'Ii�•;::: :::: :: Yi:vY: YY: %.: Y:: <; <.: v,....... CONTACTED < _. . "r:' <• %:%; +i:Y: <. : :.•Y:•: :rt }: <.:•$ �:•:! <•:4::. <•Y: <.::< r. ::` :'r•'•::�: : if.e ..... .... .... .... •.......��. •.. n....... .... : ..••.... .. ..��•...�:..••r ....... .. .........n i, ....• "'''':,: ?i:�;, <r,.+:ik;:!::: :y::iF•i:•:•::: <::•:: ::::: •::: rn�x:. � v::;.i�:: rv: :::: .: :: .....�: ny.•.... ;,� ; � I 1 DATE READY (ROUTED) DATE NOTIFIED C —Q5 _ Go BY ) BY: Mt.) PERMIT EXPIRES 2nd NOTIFICATION AMOUNT OWING L - 5D 3RD NOTIFICATION BY ) �Ai��t��::Y::Y :.....: •: •:: :..• .. ••.. ::: : : ::..:.:.. ::• <::<::��:. Y;.l'Ii�•;::: :::: :: Yi:vY: YY: %.: Y:: <; <.: v,....... :•r, >•::Y: ti:: < _. . "r:' <• %:%; +i:Y: <. : :.•Y:•: :rt }: <.:•$ �:•:! <•:4::. <•Y: <.::< r. ::` :'r•'•::�: : if.e ..... .... .... .... •.......��. •.. n....... .... : ..••.... .. ..��•...�:..••r ....... .. .........n i, ....• "'''':,: ?i:�;, <r,.+:ik;:!::: :y::iF•i:•:•::: <::•:: ::::: •::: rn�x:. � v::;.i�:: rv: :::: .: :: .....�: ny.•.... ;,� ; � BUILDING - initial review G�- ,°-�4_ 61 ° (ROUTED) W. �VI � at - ' 0 FIRE FIRE PROTECTION: [ I Sprinklers [ I Detectors NINA FIRE DEPT. LETTER DATED: INSPECTOR: INIT: O PLANNING ZONING: D USE CONDITIONS? ' f [ 1 No REFERENCE FI-E NOS.: INIT: MINIMUM SETBACKS: N- S- E- W- O PUBLIC WORKS UTILITY - PERM REQUIRED? S [lYes No PUBLIC WORKS LETTER DATED: INIT: 0 OTHER INIT: 4 BUILDING - final review , (1_, -� () TYPE OF CONSTRUCTION: UBC EDITION (year): INIT: , BUILDINC.PERMIT APPLICATION TRACKING PR ETNA E bib on o n SITE ADDRESS ;1 n SUITE NO. . 1/1 ✓D 5V V-kt-1 LP 1114 PLAN CHECK NUMBER c 3- Lino INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) ow. swat ?a :Z.4 ;1 : =a : =a 4 ._ 0CC. SQUARE oa. swat saw CCC. TOTAL TOTAL DEPARTMENTAL REVIEW "X" in box Indicates which departments need to review the project. REVIEW COMPLETED Roofing: Contractor Information:, Custom Roofing 8001 Fifth Avenue South Seattle, WA 98108 CUSTOR *291M9 9 -30 -90 ovii r CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 ADD( IC/1 11c0N trill`; 1 Ill FILL ED OUT C011ll'I f It I Y c vS Qti\b x1 ADDRESS (02 ch PA,T G DATE APPLICATION ACCEPTED BUILDfta PERMIT APPLICATION DESCRIPTION BUILDING ! PERMIT FEE PLAN CHECK FEE `> :;::AMOUNT::;:: RCPT::• BUILDING =SURCHARGE OTHER: T :. AL. DATE H SITE ADDRESS SUITE #t VALUE OF CONSTRUCTION - $ '075? s2 �'� dl PROJECT NAME/TENANT / ASSESSOR ACCOUN I It Boq hmwe 4 3 S ,23 c / 2 (10 5 - o- TYPE OF U New Building U ddition U Tenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Storage ( ,R eroof 0 Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: 'r a � r co r c x -ro PLy Uuboo Q5 e BUILDI G USE (office, warehouse, etc.) NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: Tenant Space: Area of Construction: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 11X No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER / 16. 4,K �C L � ., �, (1,m PHONE 5-7s ackh ADDRESS CONTRACTOR 1... V �' k �J 10 < . C' � _. � � ( � r . - , r ��=- t� � r ADDRESS WA. ST. CONTRACTOR'S LICENSE • �� _ a L U \ y 2 \3 EXP. DATE ARCHITECT 0 SS . PHONE _ 387 -- 16M) ZIP PHONE ( 3a (,�,� I�q ZIP crr o � BUILDING OWNER SIGN OR DATE AUTHORIZED AGENT PRINT ' ME 0 /l 11 04/4 J ADDRESS ` (-h kVia. 5 CONTACT PERSON I )) v( (,0 00(t) de PHONE 76.2_--975-0 t r75c ) CITY /ZIF � 4r P PHONE '1 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT if the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations.. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION EXPIRES o7/01/110 COMMERCIAL - NEW COMMERCIAL SUILDINGWA • Completed bUik ng *mit applicatl Alse uot , AOoount Ruin GOmpf444 buiidinp.Nenr!(t app {4d ses orAocount.Nu don end cti+�'if rior;: taompiatod utility permit . , , , S0• (6), Bets of clvil drawin M01E � ur�iry pernir subrrrltlal: regrrbamanrs RACK. STORAGE / ick/aM 0040 bna Ol f/CAR ( � .., :and ly(I�..waya Ot! p/M► 8truobJnll calaAationa stamped byr 6. W 6npineer (rOCk 4bryp 8' (tnd o' RESIDENTIAL NEW fi1NOLE#ANILY DWEUZ Q$IADO C `�' ComplsMd building P apf?l !. (CM C�iY dos: >; :.... ....... ............................... .... .......... ee412) of fl), fol r s040 A000unt Nu 4(2): of 4/0044p:.404,41 9ita plan �,......�. (Qn plrr�, slaw apw • Foundation plan apa«s Root plan '.Roof plan► ! .::. <;`. tl .8ufiann el.v bons p (dl :yfs∎ 4 ,E9ulldip 1444- 4HOtlOA >: Wuhir upd Step Enor compalo us* permit appl :.:.....:..:.:.. .:.::.:......:..::..:.:..::.:.: . (6) sets of silo plans shown _ . . Butkirnp site plan u1Wty • site <00 inv.,. lc tort and. chrakfht fat:. Aar apog plloa♦.Rnd knfrm *'n pp. cartafNkMts. : ; S6BMI1TAL CHECKLIST of adlaosn (oons.ngt w aif) lrnant: ml clms niionu! 0.00n or squere. > sP : MfI1h use of ONOl1 :, ,tOOtO s. wells,; sxis� waM� rrd waGs eon f� d ............. • • OMMER $AL TE4AHT IMPR0VIM nt N p lfny,uliily w ; llNNt: ib1;N Account 8001 5TH AVENUE SOUTH SEATTLE, WASH. 98108 PHONE 762-0170 City of Tukwila 6200 Southcenter Blvd. Tukwila, WA 98168 Bon Home Furnishings ( Lower Roof Only ) 17750 Southcenter Parkway Tukwila, Washington $ubj: Reroofing Gentlemen: Owens- Corning Specification # 31 -TC Insulation -- 3/4" Fiberglass.. September 25; 1990 Custom Roofing has installed a new built up roofing membrane in compliance with the following specifications. The existing roof was tore off to the deck prior to the new roof assembly. Sincerely, Custom Roofing, Inc. Per Owens- Corning specifications this roof has`a'; : Class "A" rating over 3/4" fiberglass insulation. : Please see copy of UL Specification index attached. E.L. Larson, President PERMA PLY-R, PERMA PLY-6 & PERMA PLY-1V UL Specification Index Class A PERMA PLY -R PERMA PLY -8 PERMA PLY -IV Slope Deck MM. Thickness Max. Thickness Gravel 43 -TO ` 4270 41-TO 3" NC,C,PL 3" FG Unlimited 43E-TG 42E -T0 41ETG 3' 43P-TG 42P-TG 41P-TG '/." 43 -IG 42.10 41 -I0 3" NC,C,PL 34" FG, %" P, 3" Won NC dock only Unlimited 43E-IG 42E•IG 41E -IG 3" NC,C,PL AC Foam I1" max. slope for PLI 4" max. 43P -IG 42P4G 41P40 3/4" NC,C,PL 33-TO 32TO 3170 3" NC,C,PL 3" FG Unlimited 33E -TG 32E-TG 31ETG 3" NC,C,PL 33PTO 32P-TO 31P-TO /." NC,C,PL 334G 3240 31.10 3" NC,C,PL V." FG, 3/4" P. /." Won NC dock only Unlimited 33E -IG 32E40 31E -IG 3' NC,C,PL 33P -IG 32P-I0 31Pd0 A" NC,C,PL 2370 2270 2170 3" NC,C,PL 3" FG Unlimited 23E-TO 22E-TO 21E1G 3" NC,C,PL 23P-TO 22P-TO 21PT0 %.' NC,C,PL 43 -NO 42 -NO 41 -NO 3" NC,C,PL 43E•NO 42E -NG 41E -NG 3" NC,C,PL 43P4N0 42P•NG 41P-NO 3" NC,C,PL 33 -NG 32 -NO 31 -NO 3' NC,C,PL 33E-NO 32E-N0 31E-NO 3' NC,C,PL 33P4N0 32P -NO 31P -NO b" NC,C,PL 43•X0 42•X0 41•X0 3" NC,C,PL 43E-X0 42E-X0 41E•XG 3' NC,C,PL 43P4XO 42P•XO 41P-X0 V " NC,C,PL 334X0 32 -X0 31•XG 3' NC,C,PL 33E•XG 32E -X0 31E -X0 3' NC,C,PL 33P4X0 32P-X0 31P -XG h" NC,C,PL Roof Insulation NA NA NA NA Mineral Cap 437C 42•TC 41 TC 2" NC,C,PL 3:" FG Unlimited 43E•TC 42E•TC 41E-TC Unlimited 43.1C 42 -IC 414C 1" NC,C,PL %" F0, 1" P max. 1" slope A max. 1" elope Unlimited 43E-IC 42E -IC �4 2" NC 3i' P,'/." W Unlimited 33TC 32-TC eC+M� 2" NC,C,PL %" FG Unlimited 33ETC 32E-TG C ' 33 -IC 324C 31 -IC 1' NC,C,PL FG, P, W, A max, 1" slope Unlimited 33E•IC 32E -IC 31E -IC 2' NC,C,PL 3" P Unlimited 23TC 22TC 21TC 2' NC,C,PL 3" FG Unlimited 23E-TC 22ETC 21E-TC 43.NC 43•NC 41 -NC 1' NC,C,PL NA 43E -NC 43E -NC 41E -NC 2' NC 33-NC 32 -NC 31 -NC 1" NC,C,PL NA 33E -NC 32E -NC 31E -NC 2" NC 43 -XC 42-XC 41-XC 1" NC,C,PL NA 43E-XC 42E -XC 41E-XC 2' NC 33•XC 32-XC 31-XC 2" NC,C,PL NA 33E-XC 32E-XC 31E•XC 2" NC Emulsion 4378 42-TS 41-TS 3' NC 3S' FG,3/4" P 1" max. 43ETS 42ETS 41E-TS 'g' NC 3/4" F0,'/.' P. /" W, A 4" max, 43 -IS 42.18 41•I8 3" NC 34" FG, 3" P 1" max, 43E -IS 42E -IS 41E•IS '/r" NC 34 F0,'/." P,'/.' W, A 4" max. 3315 3278 31T8 3" NC 3" F0,' /." P 1" max, 33ET8 32E-TS 31E-7S 'h" NC 34" F0, 3" P.' /4" W, A 4' max. 33 -IS 32 -IS 31.18 3' NC '/." F0, 3'" P 1" max. 33E -IS 32E -IS 31E -IS h" NC 3/4" Fa, 34" P, /" W, A 4' max, 43•N5 42•NS 41 -NS 3" NC NA 43E -NS 42E-NS 41E -NS 43-XS 42 -XS 41 -XS 3" NC NA 43E -XS 42E -XS 41E-XS Aluminum and 4376 42 -7S 41.75 2" NC PG 1" max. Acrylic 43E-TS 42E-TS 41E-TS '/.' NC FG Unlimited 'b" NC FG 4" max. 434S 42.16 41.18 2" NC FO, P 1' max, 43E -IS 42E4S 41E -IS 3/4" NC FG, P, W, ISO Unlimited y" NC FG, P, W, AC 4" max, 33 TS 32-TS 31 TS 2' NC FG 1' max. 33E-TS 32E-TS 31E-TS '' /.' NC FG Unlimited 'V." NC FO 4" max. 33 -IS 32 -IS 31.15 2' NC FG, P 4' max. 33E -IS 32E -IS 31E -IS ' /." NC FO, P, W, ISO Unlimited '/," NC F0,P,W,AC 4 "max. 43 -NS 42 -NS 41 -NS 4" NC NA 43E -NS 42E -NS 41E -NS '/." NC 43 -XS 42 -XS 41 -XS 'I." NC NA 43E -XS 42E -XS 41E -XS 'V." NC Interply/ Surfacing/ Slope Bitumen Type Materials per 100 ft FIBERGLAS Roof Tape 4'x8' 37.5 lin ft 3'x4' 60 lin ft Bitumen (Tape) II, III 8 lbs Perma Mop 8 lbs Interply Felts 3 plies Bitumen 0 -'/" II, III 75 lbs T /z -3" III 75 lbs 0 -3" Perma Mop 75 lbs 3 -6" IV 60 lbs 3 -6" Perma Mop 60 lbs Surfacing Asphalt 0 -3" III 25 lbs 0 -3" Perma Mop 25 lbs 3 -6" IV 20 lbs 3 -6" Perma Mop 20 lbs PERMA CAP 75 lbs 1)WI NSfi I MN , NI. FIBERGLAS C Insulation/Tape/Cap e}" FIBFIBERGLAS Roof She Asphalt 33-TC 32:1C ( 1 TC) Perms Mop 33E-TC 32E -TC 31E-TC PERMA PLY R PERMA PLY-6 PERMA PLY-IV itrAINIIII Roof Tope Req'd 12" FiberploS Roof Insulation Only 24' Roof Tape Roq'd 36" 3 11 1 3• G • I l 2' sldelnp fOE' 1e' PERMA CAP ■ Nominal Installed Weight-210 lb /100 ft' Weights exclude roof Insulation and are provided for system design consideration. Application of Insulation Apply FIBERGLAS roof insulation in accordance with specifications with Joints run continuously in both directions. On multiple layer applications, offset joints of each layer a minimum of 8" from all joints of the previous layer, Apply FIBERGLAS roof tape over all joints (top layer only on multiple layer applications) and edges, embedding in hot bitumen, using not less than 16 lb/100 ft' of roof tape. Tape end laps shall be a minimum of 4" Application of Plies Embed three plies of PERMA PLY in shingle fashion (starter sheets required), lapping 24%" into uniform mopping. of hot bitumen, using 23-45 lb /100 ft' per ply. Plies may bo left exposed up to six months without surfacing. Application of Mineral Surface Embed 12-ft. lengths of PERMA CAP (18 -ft. in Area ill) with 2" (min. 1 ") side and end laps into uniform solid mappings of hot bitumen, using 20 -30 Ib/ 100 ft? PERMA CAP and laps shall be staggered minimum 3 ft. All Areas General Note All general instructions contained in the General Requirements section of Owens - Corning Built -Up Roofing Products Reference and Application Guide, Pub. No. 5 -RW -13121 shall be considered part of this specification. Drainage Roof decks must be graded to drain all water freely. Drains shall be sufficient in number and size to assure rapid elimination of water from the roof surface. Nailing Treated wood nailers are required on inclines exceeding 2" per foot to help secure insulation and roof membranes to non- nailabla decks or to decks with insulation. Nailers should be the same thickness as the insulation and should be installed perpendicular to the slope on approximate 8 foot face -to -face for slopes up to 3" per foot and approximate 4 foot face -to -face for slopes greater than 3" per foot. Felts are to run parallel to the incline and must be secured at each nailer, a maximum 12" in from the back edge of the felt. Each nail must be covered by succeeding plies. High temperature areas may require nailing on lower slopes. Ply Edge To Ply Edge PERMA PLY "—.. 1:! ��.~-- L�: -,,,y -.! ti �a:.� '•.— !:_„., ' -- !a'_'-, Bich of Ply To Ned 1r I 1111 f 111 n„' I u„ I 11 i I "'' Flashing. See Flashing Section of Owens- Corning Built -Up Roofing Products Reference and Application Guide, Pub. No. 5 -RW- 13121. PROJECT: M Aryl—i_ Ce.,eir PERMIT NO. (' 246, SITE ADDRESS: ( '7 '? g _ . ,S, C. _ 1€4.,, DATE CALLED: TYPE OF INSPECTION: ...D DATE WANTED: Co — S— 1' 1 SPECIAL INSTRUCTIONS: REQUESTER: 6tAj PHONE NO.: INSPECTION RESULTS /COMMENTS: � nienenTno. n•vie. / ('_ CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 Wthhalaravotoia Ite Type of Inspection Site Address Requestor Special Instructions /77 , ��t� Inspection Results /Comments: Inspector CITY OF TUKWILA Buil ' Department 6300 thcenter Boulevard Tukwi , WA 98188 (206) 431 -3670 Date Date Wa Project Phone # INSPECTION RECORD PERMIT # �n Da to JO —2_ 2._.—een )n. t h Lumpkin GENERAL CONTRACTOR Re . rks*: Attention: Mr. ,ary Shank 0 For approval %1 For your use 0 Per your request 0 Approved as noted 0 Not approved: please resubmit ,lob Number 9135 Code signed Ned C. Lumpki n/ RT To: City of Tukwila Dale. April 30, 1991 6300 SouthCenter Blvd. Job Name: Pavillion Mall Minolta Bldg„ Community Development doh Number 9135 Tukwila., WA 98188 We are sending: CXAttached 0 Separate cover by Vendor Quantity Document Number Dated Description Stamped Drawing from Paul Patrick • MAY O 1 1%91 C11 Y Ur. I . UNV'JlL � PLANNING DEPT_ TRANSMITTAL RECORD Please note the conduit repair that was discussed, at the Bon, was taken care of several months ago. 1827 Eastlake Avenue East • Seattle,Washington 98102 • FAX (208) 320.1825 • (208) 328.1128 "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 11 12 13 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 17750 Southcenter P OTHER AGENCIES: BUILDNG PERMIT INSPECTION RECORD (Post with Building Permit in conspicuous place) on BUILDING �� I ( PERMIT NO. (.12 0 DATE ISSUED: c 2-- 9 SUITE NO.: PROJECT: Bon Marche Home Center CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION • When forms and rebar are in place. 3. SLAB - If structural slab or if undersiab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Battles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 05/17,60