Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 6279 - Nikken Seattle - Model Home Framing
7715-E-57M4717— V-N UBC EDITION (year) 198 SETBACKS: N._ S - E- ADDRESS 1325 Fourth Avenue, Suite 1940, Seattle, WA W - FIRE PROTECTION: DSprinkiers (I) Detectors ❑ N/A UTILITY PERMITS REQUIRED? ❑Yes No (through public works) ZONING: BAR /LAND USE CONDITIONS? ❑ Yes ® No CONDITIONS (other than those noted on or attached to permit/plans) ZIP 98072 Beoing Oregon Mesabi Trust PHONE 624 -4494 ADDRESS 1325 Fourth Avenue, Suite 1940, Seattle, WA ZIP 98101 CONTRACTOR Shimoi Construction PHONE ADDRESS 6905 South 120th Place, Seattle, WA P ZI 98178 WA. ST. CONTRACTOR'S LICENSE # SHIMOC *173CD EXP. DATE 2-03-91 ARCHITECT Lee Kirk, Architecture & Planning PHONE 464 -1880 ADDRESS 19037 N.E. 167th Street, Woodinville, WA ZIP 98072 CITY OF TUKWILA Dept. of Community Development- Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING (i2 fl PERMIT NO. DATE ISSUED: SI PROJECT NAME/TENANT Nikken Seattle, Inc. TYPE OF ■ New Building ■ Addition © Tenant Improvement (commercial) WORK: ❑ Rack Storage ❑ Reroof ❑ Remodel (residential) O Other: DESCRIBE WORK TO BE DONE: Construct framing portion of full scale model home. c 01)f COMM IAN(' FLOOR SQUARE FEET TOTAL OCC. LOAD SQUARE FEET SQUARE FEET OCC. LOAD OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC, LOAD USE APPROVED FOR ISSUANCE BY: I hereby certify that I have read and exam ned this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. SIGNATURE: PRINT NAME: N A T T P OA COMPANY: A/ (;K - f 5' fdA rte (n! C M This permit shall become null and void If the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 0772J DATE ISSUED: CERTIFICATE OF OCCUPANCY NO. 360 Midland Dr BUILDI143 PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) t • � l BUILDING PERMIT FEE PLAN.CHECK<FEE BUILDING'SURCHARGE 415.00 • 2240 MEM THER: TOTAL . 270 ^00 4.50 689.50 PLAN CHECK NO.: 90 -416 i BUILDING OFFICIAL ASSESSOR ACCOUNT # 883650 - 0100 Demolition (building) DATE: 0 DATE: l d - l 2 CI 50,000.00 PERMIT NO. CONTACTED L- ail Me,----i _ (Init.)--013' DATE READY DATE NOTIFIED 1 a 11" ci a PERMIT EXPIRES 2nd NOTIFICATION BY: ((nit.) AMOUNT OWING 1 p 1 � `''� . 50 3RD NOTIFICATION BY: (Ink.) BUILDING: PERMIT APPLICATION TRACKING PR ECT NAME N lk-e n - -e0z1p SITE ADDRESS SUITE NO. PLAN CHECK NUMBER C I 0 LI 00 INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) 04 .0 .. SQUARE WAD . FEET LOAD bcc. FEET LOAD FEET • LOW SQUARE FEET OCC. LOAD DEPARTMENTAL REVIEW "X" In box indicates which departments need to review the prolect. DSP 1a BUILDING initial review IZ FIRE . Ire :T1 =TIif • 1 1 Ji l I'd O PLANNING O PUBLIC WORKS O OTHER ,BUILDING - final review REVIEW COMPLETED �a' r�� l o.tL -90 �SROUTED) 10 -12 -9a 10116,/q0 FIRE PROTECTION: Sprinkles ❑ Detectors [ ] WA FIRE DEPT. LETTER DATED: / o -i i,- qo INSPECTOR: S jZ INIT: INIT: INIT: INIT: /046-X INIT; � _ � 14.4 00 ^Mid loLnd 31r 1JsU�`�i�l)JT: d ate REFERENCE FILE NOS.: MINIMUM SETBACKS: N- .., ..... ............................... .,... .+. e. r�::��. : +:: $,'•.4: +: }ice +:':.�.....��.......��..... �.. �,�� ate prove - UTILITY PERMITS REQUIRED? [ J Yes No PUBLIC WORKS LETTER DATED: Ia °i ~ `TU TYPE OF CONSTRUCTION s- UBC EDITION (year): 1%68 as CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 A PPLICA TION ll1(J' T f3f FILLED OUT COMP( L TEL Y ',rltl� MIZ r 6T7] -xs` UILDING PERMIT FEE ' HillEXERINEMISEINEEMEMBINIONEESENNI fie. ►,� PLAN CHECK NUMBER SITE ADDRESS P)-2 €o HiDL/afvib vr_ivE PROJECT NAME/TENANT TYPE OF O New Building WORK: O Rack Storage DESCRIBE WORK TO BE DONE: 6 G..r �M��� ?Oj-Tlog OF FUl,l, PEE: BUILDING USE (office, warehouse, etc.) Or p 6E- /VtlP�f:l-Iv U NATURE OF BUSINESS: W I.k�PI.E ' '/ t'Eh oL WILL THERE BE A CHANGE iN USE? No Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: -70 88C� WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? E No O Yes IF YES, EXPLAIN: PROPERTY OWNER ADDRESS CONTRACTOR ADDRESS WA. ST. CONTRACTOR'S LICENSE # ARCHITECT ADDRESS i HEREBY CERTIFY THAT t t T R UE ANDCORRECT, AND" BUILDING OWNER SIGNATURE OR AUTHORIZED AGENT � 0 CONTACT PERSON Lf�fL, V.I -1L PHONE ,f & o APPLICATION SUBMITTAL In order to ensure that your application Is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community DeveI' ment prior to application si. hmittal. ContaM_th' Pat?"it (oordInatnr at N 1 - ?a7" ^•1nr to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architectengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED SUITE # (Q 50 - O LOO ildin Addition .. Tenant Improvement (commercial) ❑ Demolition (building) O Reroof 0 Remodel (residential) O Other )0- 5- qo Tenant Space: 419 Area of Construction: to .1 • PRINT NAME 1(4, ADDRESS BUILDIkG PERMIT APPLICATION TOTAL VALUE OF CONSTRUCTION - $ ebb 60 (000 ASSESSOR ACCOUNT # t4 ) ANt EXKAMINEt THIS APPLCATION IA !' KN DATE APPLICATION EXPIRES PHONE 24 4414 I PHONE EXP. DATE ZIP 9 & PHONE 4 u3e30 DATE (D ZIP ZIPlpQZ,L PHONE 4, 4 lm ?D CITY /ZI 00 0 07/06/90 i COMMERCIAL NEW COMMERCIAL �UILDINGS/ADDITIOWS fl Competed building permit application (ane for each structure Assessor Account Number Two sets (2) of the following r SpidIlCatlOnS . .» Structural calculations stamped by a Washbi Soils report stamped by a Washington State licensed i E TopographkI survey Eneigy caiwlabons stamped by a Washington State licen engineer or architect Lego dscdpo Working drawings, stamped by a Washington state ucensi arddtect, which indude • Architsctr& drawings • Structural drawings • Mechanical drawings 'Elevalions • CM drawings • Lcape plan E Completed utility permit application (one for entire SIx (6) sets of civil drawings NO7L Soe u&iSy permit application and check//st for aubmltW taqukem anI. RACK STORAGE E Completed building permit application .M$*5or .NMflbUF Twa (2) sets at plans, which induda p howl n ........... HuNding floor .:.. • Enlira apace where . racks will .b�k. • ExIt doors • D1nensioiie of:aU dtstoa Tenant space floor plan showing rack storage la exits NOTE 1ncM drnenslons of racks (hoIghf M an e xit fl --. fl . . ........ 11 Structural calculations stamped by a Washington State licans �ngknper (rack, tbtage 8' and oust) RESIDENTIAL NEW SINGLE-FAMILY DWEWNG�/AO�IflON$ F Completed buildn permit application (one for each structi [J Legal descriplion Assessor Account Number Two sets (2) of working drawing B, which include 'Foundallon plan • Roar plan • Roof plen SUBMITTAL CHECKLIST COMMERCIAL TENANT IMPROVEMENTS E Completed building permit application (one for each structure or lenent) Assessor Account Number Two (2) sets of canstruoton plans, which include Ii Site pMn. • Location of tenant sp� • Existing and proposed parking OveraN building plan • Tenant location • Use of adjacent (common wall) tenant • tveraq,dlmsn� tons of bulldirp or square toot oar plan of proposed tenant space Tenant space plan with use of each room labelled • Exit cbors egress` patterns • New walls, existing wail and wage to be demolished alls *ions showing wall construction and method of nt for floor and ceiling : REROOF. . :...::.:. :: .... :..:.:.;:, .:..: .....:... n Completed building permit application (one for each structure) Li AS$9$SOI Account Number :.fljNththied�a1bfri� eisnr�of,.rraterlai being removed, and !'' .. - ANTENNA/SATELUTE DISHES E Completed building permit appilca - Assessor Account Number Two (2) sets of plans, which Include' J site Plan (showing bulking and locition of sntenna/.ateliite dis DtI*i M'fflt method .�f:stt. . �h Structural calculations stamped by a Washington State %ceni materisiF b�lng initlled NOTE A oerAVbar Iiequ fr Inspection and sign , RESIDENTIAL REMODELS Roof plsui • Building elevations (all views Building cross-section t3Wctu ............ If NOTE any u#ry worn is ro osr acne prailde ut/lily permit and ;PlMfflfluhf bejubmi . .' Bsrlidin ale iaIIon (all 4WM$).. Building cross- section -- •$tiuctural framing plans Washington State Energy Code data Completed utility permit application [J six sets of site plans showing utilities M1TC aM'nn dte pl Qnd1jtthh c ite plan may be combined See E Narrative describing existing roof, material being removed, and Completed building permit application (one for each structure A$$si� t Numtter .:..: Two (2) sets of working drawings which lnclude f.!SltepI$fl. ... .... .. .... ........ .,. - lan REROOF$ ...: .. ............ :.:..: . ..:....:: : . ...., Completed building permit application (one for each structure) E Assessor Account Number utAlti permit aeNlkallor► and checklist for apecNfc subntltpd t�equlremerrts:. ::;. material being anstalkd: tier Is requkedpnor (a final Inspecllon and sign- ro : ,,��,, Y'~�� ���`'c_ o ns • : • • ee ype Address: 0 " D A4, it / l Date Called: Special Instructions: Date Wanted: 57-to - S . p. (n Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. INSPECTION RECORD (: Retain a copy with permit 4 ❑ Corrections required prior to approval. COMMENTS: / 4 eve e_ 4.-,5 C1 71 I lnsPect te r ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: / A . , s a a,,a? S Q -- r ,,,_ ,y d- 4,o6( l r 1) A-- r f...e s{, /o c..".- cs.5 r Address: c am%' W...-t "1--7 /- (".- O c.ee - , rot- , 79 C/i7 (T ?✓'A'_. c.), �r-.� t • %7✓.r ( •.) 4'f[� "2) / /. k/ 4-4 ,--,-, a _s____,/, ,z- ..... „.• °-",S.---:".2 4 p Requester: Phone No.: /'l 3A� / /P.,.j 74, ,o .0-e_.( 1e/�J� e l� - ,- 5 1 � E.-ar „ r . / - c - . Project: / r / ' Type of Inspection: .- Address: c am%' W...-t Date Called: Special Instructions: Date Wanted: ,= ` °-",S.---:".2 am. p.m. Requester: Phone No.: INSPECTION NO, C CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.; #100, Tukwila, WA 98188 ❑ Approved per applicable codes, Recut No,: INSPECTION RECORD c.. Retain a copy with permit Inspector: /// /().c4 4.07Z. Corrections required prior to approval. Date: 2-- 15--9' ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: PERMIT NO. (206) 431-3670 COMMENTS: 4 -d . y 2, // 41~7 Cd Y'de.'/s' , - 'f''(� G'/ i^ rCr" r 4./..• /l X1'7 r"! M4/ 4 -s / . ts' G' 4. L�j,.+ S P ect: : 1 e / / /..HC..{ �. ':e a:•: / Date Wanted: / - 2- , a grit Sped`annstruct Requester: Phone No.: Uh l -1 .'. 1 4' 1991 140V .. • .r-. A .�, r. r,�!\ G P. Project: j Pro - e � Type of Inspection: P ect: : 1 e / / /..HC..{ �. ':e a:•: / Date Wanted: / - 2- , a grit Sped`annstruct Requester: Phone No.: INSPECTION RECORD ' S Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 4277 PERMIT NO. (206) 431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. Inspector: Date: $30.00 REINSPECTION FE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Recept No.: 4015 Date: PERIOD ENDING '' EARNINGS TOTAL EARNINGS •.. DEDUCTIONS TOTAL DHDUCTIONS NET PAY ` HOURS RATE ' AMOUN ' EARNED AT REGULAR RATE AND OT OVER IME :''A ,. -. FJ OA WITHHO Ub LDING ' . oa TAI( .. .. STATE INCOME TAX ,. , .. HAVE A KAPP)" DAY 0* 1UKUILA ( EN R9? .iil ,. 00 TOTAL 30. 00 CHECK 70 0 rj (.;f•4Ai+!N i': n 06 • 40W M609 600 .i .0 MI5 t. PHONE 6 ,TS-1113 NIKKEN SEATTLE; INC- DESCRIPTION.: AMOUNT' DISTRI ACCT. NO. '" #6279 (Reinapeation Fee) DATE I. EMPLOYEE DETACH AND RETAIN THIS STATEMENT THE ATTACHED CHECK PB IN PAYMENT OF ITEMS DESCRIBED BELOW.' 'IP NOT CORRECT PLEASE NOTIFY," US PROMPTLY. NO RECEIPT• DESIRED: DELUXE FORM .WVC -2 :V -8; • UTIONS 'AMOUNT Pro k / _ i LCp ee Type of Inspection: Address: CS /2 11-7 Date Called: SP a s ruc tions; Date Wanted: -ej am „G '.• Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 "'INSPS`CTION Retain a copy with permit (206) 431 -3670 ❑ Approved per applicable codes. jig Corrections required prior to approval. COMMENTS: t, /� amore, , P7 / / z, c � ' vh h Avg,, S r . ‘ $30.00 REINSPECTION F E REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Recept No.: Dale: i CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 ltw\ INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PERMIT NO. (na PROJECT: kYi KKOn 5PC SITE ADDRESS: (on \Y\\ d 1 (Ana 1-) r DATE CALLED: e , -.-ED Co- (311 TYPE OF INSPECTION: DATE WANTED: 7..-2-6— .9/ SPECIAL INSTRUCTIONS: 30 .0.2.eef-: ) REQUESTER: 1......-(2_ illir k PHONE NO.: Li (Dli --- 1 %,10 „4-4.... l'r-f fr L11 A — /7 Ae,4) — i .-. ler 'YAC INSPECTION RESULTS/COMMENTS: JV 4 , /- 4 p e. c.„/— S , • / ci /0A e," .0: / 7 ,,./) — --,0 L, , 4, - a- - - / S e- /7--i .-r- P( 7 ' -- t;( ,,, - -,,,, 1 ---,- A ---)-- i„--7,0-t ' . (' 4 / ,..7 / /...e .-- ,..,,,--- ,--x— I.., fi , 7/ i - 2/i -,fi-P i---..0 , . / % /11 4 5 6 c.,/ e-z,e'4,40-4( - /7 . 3 •-r., 1= e''' 4- 5 INSPECTOR: la:,, p ,, . .,-,?-)_ DATE: a —7/, --4; - / CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 ltw\ INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 CITY OF TUKWILA 6200 SOUTIICENTER BOULEVARD, TUKIVILA, WASHINGTON 98188 Plan Check #90 -416: Nikken Seattle, Inc. 360 Midland Dr PHONE # (2061.433.1 800 THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER ( Nni 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277- 7272). 3. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 4. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 5. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Gary L. VunDusen, Mayor "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 X 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 11 12 ( P 13 14 FIRE FINAL Ins!): 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 I 17 BUILDING FINAL 431 -3670 BUILDG PERMIT INSPECTION RECORD CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 OTHER AGENCIES: (Post with Building Permit in conspicuous place BUILDING / PERMIT NO. DATE ISSUED: lo re SITE ADDRESS: 360 Midland Dr SUITE NO.: PROJECT: Nikken Seattle, Inc. CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if undersiab insulation is required. 4, SHEARWALL NAILING - Prior to cover, 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progre's`ses. 05717/90 IC' REQUIRED INSPECTIONS 1 Footings 2 Foundation 3 Slab and/or Slab Insulation 4 Shear Watt Nailing ■ po 6 5 Roof Sheathing Nailing Masonry Chimney 7 Framing 8 Insulation 9 Suspended Coiling 10 Wall Board Fastening 1 11 12 13 4 14 FIRE FINAI.Insp: 15 PLANNING FINAL I 16 PUBLIC WORKS FINAL 417 BUILDING FINAL PLAN CHECK NUMBER °►D - 41(0 • C PROJECT: THE COLUMNS COMMENTS APPLY TO ANO PECOMS PART OP THE APPROVED PLANS UNDER TUKWtLA BUILOINI PERMIT NUMOIR (mil No changes will be sods to the plans unless approved Oy the II//VV Architect and the Tukwila building Division. O 2 Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4732). Electrical permit shall be Obtained through the Washington State Division of Labor and Industries and all electrical work will Oe inspected by that agency (072.63631. O All mechanical work shall be under separate permit through the City of Tukwila. �,tR'] Al) perelts, inspection records, and approved plans shall be 1/� posted at the lob site prior to the start of any construction. ( 6) When special inspection Is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the building Division in a timely canner. Reports shall contain address, project name and permit number of the project being inspected. �7 All structural concrete to be special inspected (Sec. 306, UDC). O All structural welding to be done by M.A.8.0. certified welder and special inspected (Sec. 306, UOC). O All high•strengtb bolting to be special inspected (Sec. 306, UDC). 10 Any new ceiling grid and light fixture installation is required to meet lateral bracing requiresents for Satiate Zone 3. If Partition walls attached to ceiling grid must be laterally braced If over eight (01 feet In length. !2 Readily accessible access to roof counted equipment is required. 2 Engineereed trues drawings and calculations shall be on site and available to the building inspector for inspection purposes. Oocuaente shall bear the seal and signature of a Washington State Professional Engineer. 14 Any exposed insulations backing material to have Mae Spread Rating of 25 or less, and material shalt bear identification showing the lire performance rating thereof. (i Subgrade preparation Including drainage, salivation, compaction, and fill requirements shell conform strictly with recommendations given in the soils report prior to final Inspection (see attached procedure.). t6 A statement free the roofing contractor verifying fire retardancy of rook will be required prior to final inspection (see attached rocedurel. 0 All construction to be done in cenlorsance with approved plans and requirements of the Unliore Building Code 11908 Edition), Uniform Mechanical Code 11904 Edition), Weshlgnton State Energy Code (1989 Edition), and Washington Stu Regulations for barrier Free Facility (1989 Edition). ll All food preparation establishments lust have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be aide by calling King County Health Department, 296.4787, at least three working days prior to desire inspection date. On work requiring Wealth Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19 Fire retardant treated wood shall have a flame spread of net over 25. All materials shall bear identification showing the fire Performance rating thereof. Such Identification shall be issued by an approved agency having a service for inspection at the factory. 20 Notify the City of Tukwila building Division prior to placing any concrete. this procedure is In addition to any requirements for special inspection. $( A11 spray applied fireproollmg as required by U.S.C. Standard Ns. 43 -0, shall be special inspected. 22 All mood to remain in placed concrete shall be treated wood. 23 A11 structural masonry shall be special inspected per Y.S.C. Section 306 (al 7. Validity of Persil. The issuance of a permit or approval of . plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this coos shalt be valid. Dear Sir: City �f Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control Number 90 -416 (512) Re: Nikken Seattle, Inc. - 360 Midland Drive Gary L. VanDusen, Mayor October 16, 1990 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) (UFC 10 -1 (3 -1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.6), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.301) There shall be one 2A 10BC portable extinguisher located on each floor of the model home in plain view. 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit doors shall be openable from the inside without Cit y of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Page number 2 Gary L. VanDusen, Mayor the use of a key or any special knowledge or effort. (UFC 12.104b) There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (UFC 12.106(c)) Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFC 12.107(a)(b)) 3. All modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) (NFPA 13, 1 -9.1) (UFC 10.307) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4- 1.1.1) (UFC 10.302) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1 -10.2) (UFC 10.305(b)) 4. All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. Page number 3 City (o f Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 (NEC 70) (UFC 85.101) All electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (NEC 70) 5. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when . damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) All interior wall covering materials shall be fire - resistive or shall be treated to be fire - resistive, so as to result in a flame- spread rating as required by UFC Appendix VI -C tables 42A and 42B. A certificate of the flame spread rating is required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC 10.401) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. All wall and ceiling materials constructed of wood, shall be fire retardant treated. (UFC 10.401) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, SKs /7-- The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd Gary L. VanDusen, Mayor M R HARTING/ CONSULTING ENGINEER ct8 , c 'D E4A ST741/471•01..) 1.,0 N fu O 'PLU4G w wt R �..�C -� tdu to t..4.—n ou Fe4¢ iu4 aVtu , S 14T FD LAM LOO S, too c 3,5 - oss -S 0%5 6 a1 t 5 MI SG' k PPS FLOOf_. L\- O LO s *Tr Cuo occurkuCY) p1-- = I • q S 7 W K OCc-(nts 2 th ►O tSTS _IA l 5 C. Cu t nG 1,1..z /aLK4' , PsF L,L O FsF S\--vr i DL = 216 10 1sTS v(, • • 817 S. 3RD ST.,SUITE 9 RENTON ,WA. 98055 .(406) 471- 4444 FOR O.: SSMUT: N `j -�VI hw c. 5 G= 215 11.4,ty Hou sC LOCATED vu w,cr b4ous.E OR. RECEIVED CITY OF TUKWILA OCT 5 1990 PERMIT CENTER cMit.). c,1 occue g 2,5 FRI i (2.X (o■ 0 l s ) w Oc.x0 I� F R. wt, KJ N. .'--C 5 S�O PsF • 1 • H R HARTING/ CONSULTING ENGINEER ICLI R005 Low RoO F MAIL) F uZ • 817 S. 3RD ST.,SUITE 9 RENTON,WA.980SS .(206) 271 - 4242 ( ; c14.25Y7 ko) bit:4X 7 0) Ls�1 'til JOS: S � a -� - ( - ;) -- WI)(,y,O) z� � %5) o t,,Q Prt MR = 2 C= f{ L l +- t ' tq o) "I- 12)(50) ` J L.ownao r 5(0 50 L-() F 6/5 _ ? + Q JOB NO.: C I SUUIcT ()( IJ 4c4Z•Oo I "' Ps G15100 H R - (S /z) (64(! + � fzl o >() 22%„00 7 c +4 0/2)( to` o) . +( .)(910)C1 Lc► Fe -2,c) + 0/8 y 49 ►r oe r,�,�LY 1.o p t1/4t.keL � �u -. coy ipfroU 1 \(- C6 us arc e FAA Vii. F Sv P Peen ) -o u E uFA- I axe .. . Wr4 . WILL V=E 'TZ) . -{ I LOT ,A+-L ' ukt-- & ‘,rt--t.l, &E. C j SIR SD w! sti-cofre- st.rmit J1 � & O + �IALIZ +Gs4 12..45Z.1 1 22LL/1,*--- N R HARTING/ CONSULTING ENGINEER IJ - I Vl frto 1J \J.= 2 91.63* FLOOD_ X745 - r t sum 1x4-0 S - t-1 P., C16q6c3) LQ Irt- LZ,6,t-'1 s (i,(a - 6) vim° Ie vu \./EST Cry, wtLL E.■T E1Cr w ALL 1�/�'` -'�'• uT wP'LL whcu_ • • • 817 S. 3RD ST.,SUITE 9 RENTON,WA.98O55 (206) 271- 4244 \1= ;a5, * I LL "LtAck 152A 2 .6 I 5 ,8t LF %LI 1 074 gto�`t V 4.. (, + lo (C2.-512, 5 phus�tEr1o1 4 J S7 t. SA g �F'-L. = (1 (21=0 `1� G Io.l �`�1e) e �.� ' 2C4) CTR t P.LI. Z 2ct,5I -+- ,Zy> 5►S) t-- 14.111& nG.F ' �t CST ENT w1�,Ll. \f = .�l 'c C 35 �6 e 61,,L0 t 53 = ' 3 \1 9756 61 0 022-. 1-1-16.1e, (•1e, 2051/) 6)`12 sic- 2112 1 - b - N3� 63 ,1'. 4 @ -4. - ( (Z eecilk I q � y ' , Zst -1�s N/= 11. D + •1 I •(b15 ice) 1 1( 95' .i. � Hale, y6� Z 6120( rS 1 t 2,. - 14163 ( 3 -� - (4.4:T n,+ � , . 3°1513) + X1'G = 1( : vim.. . f1 ? 2m:36 6 e- pLwo lo� @ lU ‘ �cc.Ctr .t 4, It P,. r v'.'Jr, Ltikt -L- ' q6/10 + ( LLt' ) (V3iih)c114) = t\ 1,9 _ S vtr ..° L fiL 'a (UL17 * A as 1 61 ' ),q' I LZ -n' .W ey' Z�'z J "1 "101'a'31ct 1 ,153/s -L 3 Lb cov (14>41-0 �r tni (90L)' H 096',M'NOINSl1 6 tuns' 1S °$C'5 Lill 1 illNION3 ONIEMSNO) /ONIli1VH II H I H R HARTING/ CONSULTING ENGINEER 1 817 S. 3RD ST.,SUITE 9 RENTON, WA. 98055 (206) 271 - 4242 F - .! P‘ , O IJ e- Ex1 (i LL U . I uT6e. C r) SST (v) cj u C r-LL U, 6.tr (u'rsT • • '\1= fri, 1 _ c.,te, g to. 1 M(:. (26 ).+ l ►' (1447 q to n (32_a_ Cl w.) + It-1 c-'t 10 n \,I = .- t t �� s g1 v �1 6;" me: t? l KKE 105 N0.: SUBJECT: C?E IA Elcx `l 1 %•E) ( 3916) 2 5A 4.4* c. L. tiorli ct 10 ri I ■ep bei F' Loot/Lo i F wen-k Gvt-.(.941) \.1:: 0 QL= Q - 7.- 6"11") 05V56 t Frf•c4>1" ( Gb I b ► to L 5vVc's L LFIbt 4864tIct o9 ogles EAST + (2 -( +0.16.111-* 1 T ,4OF locielAto +64512 S PAP -lip C2c�� I NJ 253,, 5 SIV A 'c ct-tS, CAF 4ae r,, • H R HARTI NG / CONSULTING ENGINEER 817 S. 3RD ST.,SUITE 9 RENTON, WA.98055 (206) 271- 4242 EOM/ \) IJ . E y 1- (. , brel2A6R. (wC=s?) ooervl �� ► (E�sT) 1 La T (5,F>T) oLT EST w5 C M AI+� A cadlo� • Jos: 1.91 kICE ''DEII.ObI 1-k�. JOB NO.:.. O aIDATIs - h2 Brs______ SUBJECT:, ' , I 1i 6 \ Z - 1-11" l Z l 1, I 6 1 ‘,5 bW LP \ I -_( L 9.G5 � V = 5ZYl 4) siAT, Lkt..4F- l r63 (14) + \ 2- ley + Sq.CA, ( +- 46 . 1'5414;e . 2 'NWT 3Efo ,1 ^ V 1 t v , q" v14tut,G .: " (71 Z 9. 11 I T a (,,,i Li A„6c , + . = 14 62 QL + V I v3) l RI, 5' • it + 125 = . 24q2. % 5r . - 2._s\ �;LF 1..)0m1 (w \r_ 2.5t625 X13_ =i ( -t- 1545 -� = b -}- t5 t��b ( 4 3, 2514-T 4t 6 (pi) + - 1124o tco , (2) 1;--(.5- V = 11 ( 4,, -f- ¢�y�, (.l a - 2. t 4 t405 - �. 191 L:6 210 1 > =13g 4 3,6.3k. 2,-,%kt'S 5 Fr ll t 511 ,` C. G. Six • z.x ciel 23.4 SPOgeM.44 r "- H R HARTING/ CONSULTING ENGINEER . r. Gov aPPr R R.40 F F 'L)C w� ocfr fibPa4c_14.) 4 BLoCtitU4 . ) U PPg'Q, PERMIT CENTER L A LLS vosT L'RD D 11Y 100 PTE 10111 M 1 O. LDk..D 1"0 \ /N..1 S "Pte.. 6 C. SFr--. J4.-L__ uo JELL 1-I r 8.0q SOUT1-1 l.vP-1.1 S ( 1..05.s 4C-re.) 1,40 •tom. - OP &F' -oo>' tr 0Z, Lij LL CI-MS(14) (u Siff) 817 S. 3RD ST.,SUITE 9 RENTON , WA. 98055 (206) 471 • 4444 J -LT I 1r-1" 22 vCa 5 ti Lai f 3 1x %1 -' FS I c 2Z46 a t`I� as - r . :i �/n.nia 7f1�u0 Jos: U I k. K 6�,1 • 054 • MJS S JOB NO. :_11 01/ n: SUUIcT: U l J z S X6C45 tr. a C.Z.O R�Q� 2 Z '9 � W = 2D tit (PILL 1 2 X 6 C-" t 42_111.:1 6 vSb 11 2o ,2 1 Z Z _ 5S3 1 ,1 _ .23 1 X 2 ��L (2_0,1_ CIZ .aZ� nib el 1» X to‘ 2Q vS S5 RE •• CITY O TUKWIIA OCT •5 1990 5 (6221)) (6/e) 2266C '�� 2� ►3 Z _ � 1 4zl --b 51�131.u =�I�. ti. H R HARTING/ CONSULTING ENGINEER -nW I„° 1 - 1.16 61' MAGg 1 817 S. 3RD ST.,SUITE 9 RENTON, WA. 98053 (206) 271-4242 C©tiTYWou 1 r h Oid,"11 PAZ t 2.2h� vr% L.) 20 20 ' LL) ALL CAPPOCF J. -,0,0 2->c6 • Jou. l- -e'-ti � JOB NO.: SUBJECT: . ;r rp ( 2 (1. ,`1x ►oC) 2Gt.11 � . 1 1,L 5.1 57- v . 5 _, . 12... � _ 20 -o O 00: Oyu. 9 n , •2 , A3 n2,6 2 'OP CaNtTytxicQS S�- PINT t PROJECT. OCCUPANCY GROUP TYPE OF CONSTRUCTION LOCATION ON PROPERTY EXITING REQUIREMENTS Plan Review // , ADDRESS �erMi ieba,1 Ve DATE 10 - /Z BUILDING HT. / NO. STORIES FLOOR AREA OCCUPANT LOAD DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.C. W.S.E.C. CHAPTER 51 -10, W.A.C AV NOTES: /rr/'.' / //i _r1III/. 1 J, . / . r1!/ ft AP AWMaratiliMAIMICANO 4 1P Amui= CITY OF TUKWILA DEPARTMENT OF COMMUNITY DEVELOPMENT prepared by: PLANNING DIVISION PLAN CHECK NUMBER 9D -41& M r. Duane Griffin, Building Official CITY OF TUKWILA, COMMUNITY DEVELOPMENT 6300.'Southccnter Boulevard Tukwila, Washington 98188 Re Nikkcn Seattle, Demonstration House Tukwila plan check .no: 90 -416 Dear Duane Enclosed is the revised letter from Nikken stating, that the liability insurance policy wil remain in effect for the life of the demonstration house. The revised statement of insurance, naming the City of Tukwila as additionally insured, will come to you directly from Alexander and Alexander. Please let me know if I can help expedite the permit in any other way. ARCHITECTURE AND . PLANNING 19037 NORTHEAST 167th STREET WOODINVILLE, WASHINGTON 98072 PHONE:. 788 -3730 464 -1880 RECEIVED CITY OF TUKWILA .. OCT 1 2 19 PERMIT CENTER NIKKEN SEATTLE Mr. Duane Griffin Building Official, City of Tukwila 6300 Southoenter Blvd. Tukwila, Wa. 98188 Dear Mr. Griffin: Nikken Seattle, Inc. intends to construct a demonstration house to train and supply a better idea of Western framing const- ruction to professional contractors from Japan. Tours of up to 8 Japanese contractors will visit Tukwila twice a month for 5 days training sessions. 3 days out of 5, we will show a basic of structures and demonstrate installation of building products by a registered contractor in the State of Washington. Other 2 days, we will take them to our suppliers in this area. Japanese visitors may access all lower floor area of the demon- stration house, but may not enter upper level rooms with open floors. Permanent barricades will prevent entrance to Bedroom #1, Bedroom #2, and the Dressing room. Handrails and guardrails that follow UBC section 1711 standards will protect students on the stairway and upper bridge. As demonstration requirements change, Nikken may re- configure the lower floor within the perimeter of the original plan. Nikken will not re- configure the upper floor until appropriate plans are approved by the Tukwila Building Department. A $5 million liability policy issued by Alexander and Alexander insures contractors in training against Nikken's negligence. This type of policy will remain in effect for the life of the demonstration house. Additionally, Japanese visitors have travel insurance covering their own accidents. Nikken Seattle will not use the facility beyond the restrictions listed in this letter. Nikken further agrees to hold harmless and indemnify the City of Tukwila from any damage claims resulting from the use of the structure for training purposes as described in this letter. Yours truly, n NIKKEN SEATTLE, INC. 360 Midland Drive Tukwila, Washington 98188 Tel. 206.575.6244 Fax. 206.575.6337 Mat Kajiw ra Vice President Nikken Seattle, Inc. October 5, 1990 RECEIVED CITY OF TUKWILA OCT 1 2 1990 PERMIT CENTER TO: PROM: DATE: SUIJICT: Y�Y (10 /T2.MEM0) City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 1204) 433 -1800 Gary L. VanDusen, Mayor p c MEMORANDUM /04,0( cyria oretik4 -e N ' C7 J ft. .s ' ! ci I l /-- 1/ • • e..-07 cv7A I145ei r• files 2 pity- ) 1. pt /a� S viQ ? Q.. © /f f ske -dI 4e. dk&liptPri adri C ` e sod oc (' )(Dulci a7,1 , 1,0 g ie wad ( P J( /4 )' 1l tS 1 /�7�C �. L' � QQ, 5' �.- c¢y1 c� ��ri Co J� Z�Gj 12PN1.Pll,Pr( /'�l r kip C)/I&l - e kCefYi 5 NIKKEN SEATTLE Dear Mr. Griffin: NIKKEN SEATTLE, INC. 360 Midland Drive Tukwila, Washington 98188 Tel. 206.575.6244 Fax. 206.575.6337 Mr. Duane Griffin Building Official, City of Tukwila 6300 Southcenter Blvd. Tukwila, Wa. 98188 RECEIVED CITY OF TUKWILA O CT 51990 PERMIT CENTER Nikken Seattle, Inc. intends to construct a demonstration house to train and supply a better idea of Western framing const- ruction to professional contractors from Japan. Tours of up to 8 Japanese contractors will visit Tukwila twice a month for 5 days training sessions. 3 days out of 5, we will show a basic of structures and demonstrate installation of building products by a registered contractor in the State of Washington. Other 2 days, we will take them to our suppliers in this area. Japanese visitors may access all lower floor area of the demon- stration house, but may not enter upper level rooms with open floors. Permanent barricades will prevent entrance to Bedroom #1, Bedroom #2, and the Dressing room. Handrails and guardrails that follow UBC section 1 711 standards will protect students on the stairway and upper bridge. As demonstration requirements change, Nikken may re- configure the lower floor within the perimeter of the original plan. Nikken will not re- configure the upper floor until appropriate plans are approved by the Tukwila Building Department. A $5 million liability policy issued by Alexander and Alexander insures contractors in training against Nikken's negligence. Additionally, Japanese visitors have travel insurance covering their own accidents. Nikken Seattle will not use the facility beyond the restrictions listed in this letter. Nikken further agrees to hold harmless and indemnify the City of Tukwila from any damage claims resulting from the use of the structure for training purposes as described in this letter. Yours truly, Mat Kajiwara Vice President Nikken Seattle, Inc. NIKKEN SEATTLE Mr. Duane Griffin Building Official, City of Tukwila 6300 Southcenter Blvd. Tukwila, Wa. 98188 Dear Mr. Griffin: NIKKEN SE,Ci t INC. 360 Midland Drive Tukwila, Washington 98188 Tel. 206.575.6244 Fax. 206.575.6337 RECEIVED CITY OF TUKWILA OCT 5 1990 PERMIT CENTER Nikken Seattle, Inc. intends to construct a demonstration house to train and supply a better idea of Western framing const- ruction to professional contractors from Japan. Tours of up to 8 Japanese contractors will visit Tukwila twice a month for 5 days training sessions. 3 days out of 5, we will show a basic of structures and demonstrate installation of building products by a registered contractor in the State of Washington. Other 2 days, we will take them to our suppliers in this area. Japanese visitors may access all lower floor area of the demon- stration house, but may not enter upper level rooms with open floors. Permanent barricades will prevent entrance to Bedroom $1, Bedroom #2, and the Dressing room. Handrails and guardrails that follow UBC section 1711 standards will protect students on the stairway and upper bridge. As demonstration requirements change, Nikken may re- configure the lower floor within the perimeter of the original plan. Nikken will not re- configure the upper floor until appropriate plans are approved by the Tukwila Building Department. A $5 million liability policy issued by Alexander and Alexander insures contractors in training against Nikken's negligence. Additionally, Japanese visitors have travel insurance covering their own accidents. Nikken Seattle will not use the facility beyond the restrictions listed in this letter. Nikken further agrees to hold harmless and indemnify the City of Tukwila from any damage claims resulting from the use of the structure for training purposes as described in this letter. Yours truly, Mat Kajiwara Vice President Nikken Seattle, Inc. MIN ?OUDOTA INSURANCE ALEXANDER & ALEXANDER OF WASH 2800 COLUMBIA CTR /701 5TH AVE SEATTLE NA 98104 -7074 CODE SUB-CODE INt l j SEATTLE, INC. 360 MIDLAND DRIVE TUKWILA NA 98188 ■ CO TR A THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPE OF INSURANCE GENERAL LIABILITY a COMMERCIAL GENERAL LIABILITY CLAIMS MADE OCCUR. OWNER'S & CONTRACTOR'S PROT, AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON-OWNED AUTOS GARAGE LIABILITY EXCESS LIABILITY A OTHER THAN UMBRELLA FORM WORKER'S COMPENSATION AND EMPLOYERS' LIABILITY OTHER DESCRIPTION OF OPERATIONS/ LOCATIONS /VEHICLES/RESTRICTIONS /SPECIAL ITEMS CERTWICAA ,I R _ LEE RIRR ARCHITECTURE LEE KIRA 19037 NE 167TH STREET fiOODINVILLE MA 98072 ACOOtii $ � 3l$ •.r.'1 POLICY NUMBER 3529 03 07 NOT APPLICABLE 7966 3239 NOT APPLICABLE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW COMPANY LETTER COMPANY LETTER COMPANY LETTER COMPANY LETTER COMPANY LETTER COMPANIES AFFORDING COVERAGE A FEDERAL INS (CHUBB) a C D E POLICY EFFECTIVE POLICY EXPIRATION DATE (MM /DD /YY) DATE (MM /DD/YY) 09/22/90 03/09/91 09/22/90 03/09/91 CANCELLATION ALL LIMITS j1J THOUSAND% GENERAL AGGREGATE S 1000 PRODUCTS•COMP /OPS AGGREGATE $ 1000 PERSONAL & ADVERTISING INJURY S 1000 EACH OCCURRENCE $ 1000 FIRE DAMAGE (Any one lire) S 50 MEDICAL EXPENSE (Any one person) S 5 COMBINED SINGLE $ LIMIT BODILY INJURY $ (Per person) BODILY INJURY S (Per accident) PROPERTY DAMAGE STATUTORY ISSU! DATE (MMIDD/YY) 09/24/90 RECEIVED CITY OF TI IKWILA O C T 5 1990 PERMIT CENTER EACH AGGREGATE OCCUR Milos 5000 (EACH ACCIDENT) (DISEASE— POLICY LIMIT) (DISEASE —EACH EMPLOYEE SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL _3,ODAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE COMPANY, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE _/� e /A'ct e 4 4.4.7,, A d ©AC0110 COPORATION 10$ ADDENDUM "A" is a , 9 and between Hoe Oregon Mesabi Trust, First Interstate Bank of Washington, N.A., and William E. Hoeing, Jr., , as Lessor and Nikken Seattle, Inc. a Washington Corporation, as Lessee. 1. Ozfil>CN so EXTEND Lessor hereby grants to Lessee an option to further extend the term of this Lease for one (1) additional period of two (2) years. This option shall be exercised by written notification to Lessor no later than six (6) months prior to the expiration of the then Current Tenn of this Lease, and so long as (i) Lessee is not then in default thereunder, (ii) Lessee has not assigned this Lease or subleased the Demised Premises and (iii) Lessee continues to occupy the Demised premises. The rental rate for the renewal period shall be the fair market rental rate prevailing at the time the option is exercised and in no way shall be less than the rent paid in last full month of the initial term. 2. mum I PFENEMFNP Aim "A RECEIVED CITY OF TUKWIIA O CT 51990 PERMIT CENTER Lessor at Lessor's sole cost hereby agrees to complete the following items in referenced to the office area as shown in Exhibit "C" and the devising wall as shown in E hibit "B" prior to Lessee's occupancy. a. Tighten the areas in which the suspended ceiling has sagged. b. Add three light fixtures to the Manager's office, Roam 113. c. Clean the acoustical ceiling area including suspended grid system, acoustical tile and HVAiC diffusers. Replace all damaged acoustical ceiling tiles. d. Replace all fluorescent light bulbs as needed throughout the general office area. Repair or replace the two high pressure sodium light bulbs or fixtures, as needed, in the warehouse area • one which is located in the first row north of the truck doors, the other is located in the first row north of the office area and east of the exterior elevation of the Premises. e. Patch all damaged sheet rock walls throughout the general office area including the removal of pass through located between Roam 104 and 105. Repair all damaged holes in the existing demising wall in the warehouse area. f. Clean and shampoo all carpeting throughout the general office area. Replace the worn carpet in the corridor from the men's restroan to the warehouse door with either vci or sheet vinyl to be compatible with the existing carpet and sheet vinyl in the restroams. Clean and polish all sheet vinyl areas within both restroans and the lunch roam. IL's' S F.lHIBIZS AND MODELS Lessor hereby agrees to allow Lessee to construct residential Models or Exhibits to display the Lessee's product line, providing Lessee (i) completes all construction in a manner acceptable and in accordance with the local city, municipal and state building and fire codes, (ii) hold Lessor harmless from any and all mat:erialmen and labor liens and (iii) Lessee removes from the Premises all models, exhibits and related materials, upon the expiration of the Lease term or any extension thereof. 4. HAZARDOUS WASTE Lessor represents and warrants to the best of the Lessor's knowledge as of the Occupancy Date that no hazardous wastes or hazardous substances, as currently defined in applicable Federal, State and/or local statutes or regulations, are or have in the past been generated, treated, stored or disposed of an or at the 1 loll "A" (aont'd) Page TWo Premises or Buildings except in a000rdanoe with applicable Federal, State and/or local statutes or regulations. Lessee shall comply with all laws, ordinances, regulations and rules of any governmental agencies or authorities having jurisdiction over the Premises which shall, by reasons of the nature of lessee's use or oocuparxy of the Premises, impose any duty upon lessee or Lessor with respect to the use of the Premises, including any and all laws or regulations regarding the treatment, storage or disposal of hazardous waste or hazardous substances as currently defined in applicable Federal, State and/or local statues or regulations. Lessee shall be solely responsible for all claims of liability for clean -up costs and damages incurred in connection with the use, deposit or emission during the term of this Lease of hazardous, dangers s, toxic or harmful substances on the Premises by lessee, its agents, contractors, employees or invitees. lessor shall comply with all laws, ordinances, regulations and rules of any g agencies having jurisdiction over the Premises which shall by reason of the condition of the Premises impose any duty upon Lessor or Lessee with respect to the condition of the Premises. ADI I11U4 "A" is at♦ ed hereto arty a mart e bef i n MOMM slated Ann i lo, � . and between Boeing Ores on Mesabi Trust, First Interstate Bank of Washington, N.A., and William E. Boeing, Jr., Co-trustees, as Lessor and Nikkan Seattle, Inc. a Washington Corporation, as Lessee. 1. O'rZCN 'IO EXTEND Lessor hereby grants to Lessee an option to further extend the term of this Lease for one (1) additional period of two (2) years. This option shall be exercised by written notification to Lessor no later than six (6) months prior to the expiration of the then Current Term of this Lease, and so long as (i) Lessee is not then in default thereunder, (ii) Lessee has not assigned this Lease or subleased the Demised Premises and (iii) Lessee continues to occupy the Demised Premises. The rental rate for the renewal period shall be the fair market rental rate prevailing at the time the option is exercised and in noway shall be less than the rent paid in last full nrrith of the initial term. 2. IMINOVEMENr A[ "A° RECEIVED CITY OF TUKWILA OCT 5 1990 PERMIT CENTER Lessor at Lessor's sole cost hereby agrees to complete the following items in referenced to the office area as shown in Ex "C" and the demising wall as shown in Exhibit "B" prior to Lessee's occupancy. y. a. Tighten the areas in which the suspended ceiling has sagged. b. Add three light fixtures to the Manager's office, Room 113. c. Clean the acoustical ceiling area including suspended grid system, acoustical tile and HVAC diffusers. Replace all damaged acoustical ceiling tiles. d. Replace all fluorescent light bulbs as needed throughout the general office area. Repair or replace the two high pressure sodium light bulbs or fixtures, as needed, in the warehouse area; one which is located in the first row north of the truck doors, the other is located in the first row north of the office area and east of the exterior elevation of the Premises. e. Patch all damaged sheet rock walls throughout the general office area including the removal of pa the located between Room 104 and 105. Repair all damaged holes in the existing demising wall in the warehouse area. f. Clean and shampoo all carpeting throughout the general office area. Replace the worn carpet in the corridor from the Wren's restroanm to the warehouse door with either VCT or sheet vinyl to be compatible with the existing carpet and sheet vinyl in the restroans. Clean and polish all sheet vinyl areas within both restroams and the lunch roam. LESSEE'S Ei0IBI1S AND $ VTR Lessor hereby agrees to allow Lessee to construct residential Models or Exhibits to display the Lessee's product line, providing Lie (i) completes all construction in a manner acceptable and in accordance with the local city, municipal and state building and fire codes, (ii) hold Lessor harmless from any and all materialmen and labor liens and (iii) Lessee removes from the Promises all models, exhibits and related materials, upon the expiration of the Lease term or any extension thereof. 4. IMARDOUS WASIE Lessor represents and warrants to the best of the Lessor's knowledge as of the Occupancy Date that no hazardous wastes or hazardous substances, as currently defined in applicable Federal, State and/or local statutes or regulations, are or have in the past been generated, treated, stored or disposed of on or at the 1 Premises or Buildings except in a000rdanoe with applicable Federal, State and/or local statutes or regulatians. Lessee shall ootply with all laws, ordinances, regulations and rules of any governmental agencies or authorities having jurisdiction over the Premises which shall, by reasons of the mature of Lessee use or occupancy of the Premises, inpose any duty upon Lessee or Lessor with respect to the use of the Premises, including any aid all laws or regulations regarding the treatment, storage or disposal of hazardous waste or hazardous substances as currently defined in applicable Federal, State and/or local statues or regulations. Lessee shall be solely responsible for all claims of liability for clean -up costs and damages incurred in connection with the use, deposit or emission during the term of this Lease of hazardous, dancgeraus, toxic or harmful substances on the Premises by lessee, its agents, contractors, employees or invitees. Lessor shall eorply with all laws, ordinances, regulations and rules of any governmental agencies having jurisdiction over the Premises which shall by reason of the condition of the Premises impose any duty upon lessor or lessee with respect to the condition of the Premises. \J1KE__ SaATLE INC. &; REVISIONS BY r MvE 1,,,r t. 4 '10 I, fNi 001.j NIKKEN SEATTLE. INC. 360 Midland Drive Demonstration House Tukwila, Washington w ai r a I G HIV LI rLH I\II\IIIMU 9r 19037 NORTHEAST 167th STREET Dale 1,9 = %fit -1' 'l .) Scale I/4 - I JI `r � Drawn 1 Lk Job 100;( T Sheet Al 01 Sheets BUILDING DEPARTMENT NOTES OWNER / PROJECT LOCATION: PROJECT DESCRIPTION: PROPERTY ZONING: OCCUPANCY: FLOOR AREA: ' \ - -y F NIKKEN SEATTLE, INC. 360 Midland Drivc Tukwila, Washington 98188 575 6244 Construct a full scale model home to the framing stage only. within the warehouse at the above address, to train Japanese contractors in Western framing and component installation techniques. Shcnthing will be eliminated at the roof and restricted at the upper floor to 4' widths, to allow fire sprinklcr Now to penetrate tlrc structure. CM Industrial Park B -2 Main Floor "Garage" Unocr "Floor" TOTAL I . I f • -r e = E-D(_) D NI # I, , 11 FOAL 'rr 1,482 s.f. 400 s.f. 684 51, 2,566 s.f. 4,1e) 11 r 1/' N )" 4 ' 4 ` T I 1 .1 .�_....�._..� . -- __- \ - 1' \' I cr` ' 1 r. f I .1 - �I GENERAL NOTES 2. Dimensions shown arc to face of stud at cxtcrior walls, ccntcrlinc of intcrior walls, unlcss indicated othcrwise. 3. These drawings do not includc ncccssary components for construction safety. It is the contractors responsibility to provide adequate temporary supports, and bracing. 4. Fireplace, if installed, shall not be operable. 5. Any bearing walls removed for demonstration purposes, must be temporarily supported and braced with 4 x 8 beams supported by columns at 6' -0" on center. 6. No plumbing, heating, wiring, insulation, intcrior or exterior finishes, or weather proofing will be constructed. Any fixtures indicated are for reference purposes only. All work to conform to UDC 1988 and all local codes and ordinances. f .f) .')M $4 11 -A'f.nl TT. J OI') 'I „ - k s (27 Y �N !1ALJN p 7» TEN „d1 ° 3 � a J 17 I TIT I' 1 .1 I 1.' 0 "' " " " °" 1 2 3 4 5 II 6 9- I'I 7 3 •Sl :q -- '1c N 1 8 OE bZ Be Le 9e SL VZ cZ ze iz oe 61 O1 Lt 9t Sl VI Li el It 6IIIIIllIIIIIIIIIIIIIIIIIIIIIIIIhlllIIIIIIIIII IIII lIIIl1111III IIIIIIlIll IIIIl IIIIIIIIIIIII nilmIII IIlllllllllII lIII IllI llllllllllllllllllllllllllllllllllllllllllllllll In• 2 STRUCTURAL NOTES DESIGN LOADS: Live Roof 0 Upper Floor 0 Main Floor 40 Dead 10 10 10 2. Wood framing shall conform to the following: 3, Headers shall be 4 x 8 unless noted otherwise. 4. All nailing shall be per UDC table #25 Q. 5. Certified -eatawta-t-imvs-cor—r-oor- uw-ided -day- the-- cnaiwfac.— - -1trrern9 -remti uneat, -- i „Sc Beams /Fleadcrs Joists Framing 14- , 1 0" Suedes D Fir -Larch Hcm -Fir Western Hem aradc a 2 #2 # 2 TOTAL 10 psf 10 psf 50 psf IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN TillS NOTICE, IT IS DUE 10 Y!t THE QUALITY OF TIIE ORIGINAL DOCUMENT AINIANIMMANIIIIMMINNOMMINEINA NAILING USE THE FOLLOWING NAILING SCHEDULE UNLESS NOTED OTHERWISE: FRAMING NAILING PER UBC SCHEDULE 25 -Q. -N9 d- COMMOM -M NG- R.TgR- 0E-R00 I,ONC 1LOCEED- D4•AFNRACM. r1.Q <EJ4 c' TNItJcj jig_ , F'LUUN susA ilnL - nA,L RI71t ,Cd CCttMON MAILS AT 6" O.C. ♦'RNA 7 ALL FAn EL cUL La AND D1 -BO 0g- N AL Pitt:: . ALVnL AaL 2NTC tRAGIL WALL SHEATHING - NAIL WITH IOd COMMON NAILS AT 6" O.C. ALONG ALL PANEL EDGES AND AT 10" O.C. ALONG ALL INTERMEDIATE FRAMING MEMBERS UNLESS NOTED OTHERWISE. BLOCKED DIAPHRAGM AT Till SHEAR WALLS. SHEAR WALLS - SEE SCHEDULE ON THE PLANS. PLYWOOD: AMERICAN PLYWOOD ASSOCIATION (APA) GROUP I PLYWOOD. ALL PLYWOOD TO STANDARD TNT -APA (WITH EXTERIOR CLUE.) THE FOLLOWING SHALL BE THE MINIHUM PLYWOOD TII tCK NESF UNLESS NOTED OTItER1' ROOF - 1/2" FLOOR - 5 /8" WAIL SHEATHING - 1/2" (INDEX 32/16) (INDF.X 42/20) (INDEX 32/16) • Il r SHEAR WALL SCHEDULE 1/2" PLYWOOD SHEATHING, BLOCKED, NAIL WITH IOd COMMON NAILS AT 4" O.C. ALONG ALL PANEL EDGES AND AT 10" O.C. ALONG ALL INTERMEDIATE FRAMING. 1/2" PLYWOOD SHEATHING, BLOCKED, NAIL WITH 10d COMMON NAILS AT 6" O.C. ALONG ALL PANEL EDGES AND AT 10" O.C. ALONG ALL INTERMEDIATE FRAMING. NCUORAGE: MINIMUM ANCHORAGE - 5 /8" DIAMETER X 6" EXPANSION DOLTS AT 32" D.C. (2 BOLTS MINIMUM PER SHEAR PANEL) IN SHEAR PANELS SHOWN. 5/32" X 3" POWDER ACTUATED FASTENERS AT 16" O.C. ELSEWHERE TYP. 'I r /r p FILE COPY y 11',tt the Plan Check approvals are .•rrors and omissions and approval of IXM authorize the violation of any (if- ordinance. Receipt of contractor - prove(1 pions acknowledged ....... D.it ld - C7 ... ...... 'It No .............. 1( ; - r - ) . C I (:IIY OF ILIKWILA AP 1999 Hi ill INC I)IVISION PERMIT CENTER RECEIVED CITY OF TUKWILA al wl REVISIONS BY LEMOVE Prru2F ,41 to• 4.10 ILK -1 - � 1 ��PMIN�T F�PNS, ���YATIUI��, 1 ��TIoN Demonstration House Tukwila, Washington 41; v - ` w d e r - /-11Wrn I ca. 11J tarvu rlt�tvivuv�r 19037 NORTHEAST 167th STREET Date 19 6 jf , Pr 90 Scale I`torGp Drawn I L14_ Job 100+ Sheet A2 Of Sheets PPIJf3LL Tor rLnrF c:otJ orEN INIci ',Tr LIT w TN - -. — <�IMPiJII EPC.N EtJD: TFiJY jo TOP f LATE 24 X 30 PRINTED ON NO 10000 CLOARPRINT• U r e , \ / t L l�)!' AC. I I\I !4 r1-AN 1p2; )I, EVT to N. �PMIL� gooM Li I o iNl A I /1Ir , Io'' MI••ot'J yT 2115 AT FfL J L r?AMP.E. riNf Te-P -h (2) 'iT -UT NAILED TOEI 1 F P wli 0,1M PhoN '12215 EP<.N END r - ovlpe, uhJTINUouti t• 2Xlc TOP rrPTE w1TN No e (EVEN AT 4X , -/ - U INTEfZ10- WPLL' LPP Tor PLAT2 ' IMr' 1oN h7 (Litt -Por rLr.TL To - tur r LIAT E Pr -ovIp- ::nNTIfJUoU'i2 T o r PLr rE VLI No �PLILrCy NOTE; ALL E:N/1-1 N w LL To NPvE. GoNt rNLiou 4 , pOLJpuLE - ror rLPTE. P I?.o4 orENIN�. t1NLE ""r; No , Tor PLATES To LAr AT rL-'TE- IN1EP- �Ei.rlotJS 1 `) N o r TN �,L�vp_ - rloN 1/8,' , I J AI TYPICAL MPH FLoo 0 I. rm. ANON 1 1 2 1 t �"' I"' I�I�I 'r , I •.r � I�I�I•; . I • 1, I ,,,:,. I : I 3 4 5 6 IJf 1 F•,o01 FP AIHC I,OW WP1,i, -IN�f 1 /v ,,, I . 0 " �P 4P( _ Pa FT Et's T(P�PL IJrre -r- FLoof 1 1 I )' .75/6" PLYwa) INr6( FT 7LJf . PEg-II✓IETEF- (2 h rKlPh IJNDE4 INTEKIOP- rPF'- TITI Or- o) 2x10 Jolv=T "7/?) • I'L' {w'OOI) hl•IE.PrFIIN 2 r 10 J oI6 r<� rt Plc--P-L- wAI -L Up I /: Pti'MOD exTEKIoP. , ,NEts - ro!W I WNEKE. DAP IGPT p,{ h1FUC.TLt�PL hrPIK FrPMED ,OF (3) 2,c 12 hrrmie 2 TI?ena II/2 4 r-PIL PT 2' I(j' PI'uVE NexvIn161h, Ix(, IN - TE EIIEDIAfE, quplp --PIL .N OP IN 61 U0 1�UI t'�I FLEXIBLE RULER - 302 AWo.RU.N_ I I ,•I• I I I•, I 7 8 0€ 6Z B6 Lz 9Z 00 YZ CZ ZZ lZ OZ 61 EN LI 91 DI 'I Cl 01 It mil ._1111dnuilud1 nkh11111I11IId1I1IlII1d111111111111nlindI11111111dind1111I lln16111111finlik periG L PPNEI, pwit lloM h-N pULF. oN A• I ) NUM�E� INDICAT MIN, PANIEL LEN/11 IN FEET ° r riNcr'' or 2xb foot w.LLy oN , Ln' 1 /iR FLYwoo17 oN F IrOTINGT 5 - 6o146 4 LFL ON 2,000 P''F hot L 0 rroV106 CoNTINUOU7 CD 2 n x L Tor rui wlrN No /7rLtG&, ( AL, 4 To f�E FI-tLL LE$ TN riEGEs) \/\/.4.7 I / " , I ' _ 0 " '7 o LJ E y oNl I/41, I 0" IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT M l F -Loos, 4 V A r.1 Roof F1 / FOI..IN PAT ION I /n= I' 4 eL V:_) 9- ct CI WAIL PAP '14 4� IMPrit 2 T /EX -T 2 cPruPr 1• TErtpNT) 61' IJEw MODEL NOME (yC�i�INprE La P T ION w✓IT I, I o ( Ex 1 `TIN t rf>F4s IN T rola. 10 P ..-LNI?1)_I LINCP rl'7ED MI PLPNO n1=1VE- L ol✓PT I ? I.�N I /gin. r. I '. t j l r-XI`oTIN -j OrFVF 6.10 Irh ( CITY OF TUKWILA APPROVED U CT 7 1990 • BUILDING DIVISION Exl RECEIVED CITY OF TUKWILA O C T 5 1990 PERMIT CENTER INNINN