Loading...
HomeMy WebLinkAboutPermit 6336 - Minuteman Press - PartitionsMltJUTE/j ESS TYPE OF CONST.: V -1 hr U13C EI t1TON ( 1988 SETBACKS: N _ S - E- W- (through Public Works) © No FIRE PROTECTION: Sprinklers 0 Detectors (] N/A UTILITY PERMITS REQUIRED? Yes 0 ©N o ZONING: BAR /LAND USE CONDITIONS? 0 Yes CONDITIONS (other than those noted on or attached to permit/plans) FLORA IF SQUARE FEET 000. LOAD ARCHITECT Marvin Stein & Associates PHONE 4/1-1449 ADDRESS 2221 Fifth Avenue, Seattle, WA . ZIP 98121 USE 4 ' Office : /B -2 coin- C'ON91'I IAfJC'1- FLORA IF SQUARE FEET 000. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD : 2nd ' 710 16 710 16 TOTAL 710 _ 16 BUILDING PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) CITY OF TUKWILA Dept. of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMITFEE PLAN' CHECK FEE BUILDING SURCHARGE 117.00 3524 TOTAL' 76.00 4.50 BUILDING PERMIT NO. DATE ISSUED: S ADDRESS CONTRACTOR ADDRESS n 16300 Christensen Rd PROJECT NAME/TENANT ASSESSOR ACCOUNT # Minuteman Press 252304- 9078 -0 TYPE OF U New Building 0 Addition (x) Tenant Improvement (commercial) U Demolition (building) 0 Grading/Fill WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other: DESCRIBE WORK TO BE DONE: Construct partitions. Raymond Feichtmeir I PLAN CHECK NO.: 90 - 473 220 111 Queen Anne Avenue North #400, Seattle, WA Tecton Development Corporation 111 Queen Anne Avenue North #400, Seattle, WA WA. ST. CONTRACTOR'S LICENSE # TECTODC144BB PHONE EXP. DATE 282 -9220 9,590.00 I ZP 98109 282 -9220 ZIP 98109 19_'1 _Q I hereby certify that I have read and e . mined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. NATURE: 7 NT NAME: // ti'�,)4 SIG PRINT DATE: / _4/4 COMPANY :�F 7 it mr cal°. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection CERTIFICATE OF OCCUPANCY NO. DATE ISSUED: ttttitt /1 11 1► .... ....... ............. .• ..:..:.:.... •::...•:::.�: . }:•: }': }: } } }: }:: ^ii:;•: :.:.. .......:....:::..� A :; • :i :.. ......;: ....... +:......:::':•?::. i:% vifn; �:: : :.:'..:.:�:. }��:�':? : :• }:•ii? }: ' ' +.:.n : ?i` }i i:'L ?i_:: ji: :::...... i::' ^ {i:: i;.� ^� i.....: r., 'F.. }:: v ? :; \• }'. }} rji ?j : {: }: _}:: ?::'?i::•; ?} .;;R NO n.. ;. :. AMOUNT OWING rl(1 ;;" : "``: >: `r';:.••;: SQUARE FEET CCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET 000. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD IM .;1 .1'/.1 \'.t? / '4::•j,'y�' •FiG�y PERMIT NO. CONTACTED .-Fra DATE READY DATE NOTIFIED ' BY: I � (Init.) e PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER Gf0 . LI')- INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) G ' 55 DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project. XBUILDING - initial review 04 FIRE O PLANNING O PUBLIC WORKS O OTHER BUILDING - final review � BUILDINGWERMIT APPLICATION TRACKING PROJECT NAME n Re n5 SITE ADDRESS SUITE NO. log Cr1 o��v I 1 -15-90 1 I Zv- clo REVIEW COMPLETED I- 2i3-`10 (ROUTED) INIT: INIT: INIT: INIT: CONSULTANT: Date Sent - FIRE PROTECTION: Sprinklers (l Detectors (1 N/A FIRE DEPT. LETTER DATED: *44 — INSPECTOR: 5'2 ZONING: IBARA-AND USE CONDITIONS? fYes REFERENCE FILE NOS.: MINIMUM SETBACKS: N- S- UTILITY PERMITS REQUIRED? () Yes PUBLIC WORKS LETTER DATED: DIRE Date roved - UBC EDITION (year): SITE ADDRESS , # 1103 CH ( RD.. 7_2J.915°10,t VALUE OF CONSTRUCTION - $ PROJECT NAME/TENANT P\w of u i eo P O zi1 t4 l ti Lt5 t i) Pr_c5; ASSESSOR ACCOUNT # d-.5 )01- -i -- '7 o"/ - r TYPE OF U New Building U Addition JYTenant Improvement (commercial) U Demolition (building) WORK: O Rack Storage 0 Reroof 0 Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: e_t{ZS Cr A l I D/`JS E/P (G/ 1 /f/ (,.(/ ---) BUILDING USE (office, warehouse, etc.) 0 \ Cr_ NATURE OF BUSINESS: (se .,-- v. - WILL THERE BE A CHANGE IN USE? No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: 7S ../ - it] Tenant Space: (D Area of Construction: 6 WILL THERE E STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER (lq l // /(& t 4, F6lk- frye� PHONE 2S/2_,..42,10 ADDRESS H( E r / J MI/ 445 4 / / / . /() j 4 7 ?T �i✓4 ZIP/ 0 CONTRACTOR � .E 7) / D�� /�L ,,1/`i /` C , [HONE L v - iZU ADDRESS / G(�g/ ,/ A A/ - 7Y7 On ,5 7?26 G " -/ ZIR g'D WA. ST. CONTRACTOR'S LICENSE # 7 7 �`7 /) . /'. ' 68 EXP. DATE / ...__67b 72_--3 ARCHITECT f (f I' !1 /V • f' o� /6:d ( ( 47-t-55::, PHONE z./L./ -- / </4`j ADDRESS 2.. ..2_,( -f -/A £ Lf 5- /Q 77t.. A/4 ZIP (70/ _ / : <CERT! ::.TkfAT:1 AY a.`R .... tM EXAMI.tED`> THIS' PPLiCATIC?1 ADDaSIrtAVIf :T S A I~!IfJGORR :HtyW ZED:.' � ..... �M ........ Tki A1id °T f #E..... ':. >::::<<: «:<`<<::< > ><<: >:: :: BUILDING OWNER OR AGENT SIGNATURE _ DATE / / PRINT NA ,�c� ( / � l� -('A/ /��/ �,�/� oil I PHONE ; // f % p 7 ADDRESS 1 (0 s ab et/4 l`VSE'/V RA ., CiTY /ZIP 7w / /4 wise CONTACT P E R S O N rr � ' y b /t e u r' '-q - ( A � �C� J L� W l� � r� ; ���K1' � • t i rv' " PHONE Lf f .,s X 7 r� 1 1 J � r7 7 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 Af'PL ICA TION I11U(; T Elf FIL - LED OUT COIl1F'LETLLY BUILDII3 PERMIT APPLICATION �] =Ia:l i j 1 r•]; 1U•1"; IMEMENINSII . e c nialnIEVERNEMENNIMMUMMINEMISIN ''fib M 1 IEMISFA TOTAL APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Cc the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date 01 application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES 5 15 -q COMMERCIAL NEW CO ti .............................................................................................................................................................................................. Completed building permit structure . . • . . • ••• ••••• • Assessor Account Number •:TWO eat", (2)01 the • S " Soils fti).vot.snved by a Washington StatesjiCenSed. Topogrhki survey Energy caJjIatione stamped by a Washington State I engineir or architect • off .:•Waitintiav■itirlii, „Stamped by a: WeshintitaEtatel. 'Site plan ArchIIscWrsl drawings Structural drawings Mechankal drawings Elevations . . Completed utility permit applicadOnOns for an Six (i) sets of civil drawings ".:: d utilltyitennit bon an RACK STORAGE Completed building permit application • iWo (2) sets of plans, which ifiO • Building floor plan showing • I.Exit door* NOTE lncMb i*nQns!ons of racks (he and xft ways on :SITUCIUral.cildulatient.stampedby;a:;WaShO engineer (radii stompe 8' and over) RESIDENTIAL Completed building permit application (ane tot each su . . ; . Two sets (2) of working drawings, which Ii • .• SUu plan S6BMITTAL CHECKLIST •; Roof plan „ .„. BiANdflgiek•Ya, . Building ins; on • . • . ral framirl•Df!,., ••• D Washington •, Sta Energy C ode data • • • permit applicatio tad utility ParnI • Completed •• , . ,..;„,.. • .; : of site plans showing utsis plan and utility site site Pia an d railsipermir efP11cdtir • eoglia Mfenn #. butSOW.Gri. ' plan may be men . lii 00:.,,,A7•<.'. i'.01.11?•::40:'''''''' 4tin0P...,0.P, :::: , ::::::.':: :: :: : :.. ...litIN..:777:::•:::'.,.;-:::'''''''..... .,..iaht:::::::::::66 ...,...,..:..,1::Zliiiiii..;::::::.:':''' . .. ..:•:::,,..,'66:'WO!•!?::40...r.:1::':::'1''''.:::''''' Overa .....:::•,...-...::.... . ... .. •ms:::i*.Oritii.0 17:::;::1::::::::':.:::::::;:::::::::%:;:.;.:....:.:::::,iiiiii(..!:':::]:::,.„':' ;;T !0'.:0;i7,99.....to0Z4::.......;•.!..,, ..f.,.....:„........i......---op!!!!!...:.,,,•::::•41tb.q.Z:::?.•::::•.....::•,:-1?,•:•••• ••••• • . . :..:•••,.....,....,,,•::::-..;.:.:i•...• i;isp.i Ex t iiiialli': ; •••••..; , • . .,....:.:.:.,::,,,,itie -,..i....041 l)1.:.!..- ... ..„„ii.ii(.1!!!...!..7-,..- ....,,.....„.„.... . . . Floo ',..•-••::„ oft'r......„:„.:::..::: 7 aii%#!1......... 666al........0.:.,!!;!........,.....„...,:::::.7,:...:, iia.o. !...:.i'.6‘c,,....... ....000!ii::.if....‘.',,.:yo:;:iiv.,...,.:1.::1!::,i0.,:i!orti!::....:.7i:..:.0...i., jh:,.....-bei:,:'•:::::,.....:::.;.i.....:oi::,....:':iiiii:0:60.i!..:', ..i...ii:,. 01;151ed..., '0Y..i.„:i.''''''''' • ..: • :.: ,..:A• :.: .• 1.:..f.:::::.,„,....... , . • c al c ulations .:,..,.•,,...:::!:: . . Ai;.:1!..:... '''.... . Ubty work Is .. a,i,b0•1?...:::..!,•••••.„. •. i. i .ii•OY . ..,..: tri4Pt° a n • - , • • for ....- . , ..... %-..:.-- ... ..,..::::•:,•:.:'... . . • • • .• .....,,,,,- ......neatori:.:.:7::::.,.....„..:::::::: 4 *: i1N::". . . .....:..p011::::::::.:::::::::::::.,:::.!;:i.:::::::!:::.:•::::::':::::: ..................................................... „... Rop.......,.....::::, 64)041..."?...,,_,nib..• timio...,,,,,„..,...„ .„...,:"..., and it'413ti.:::,...:;;.:.......:.;':..,:.,i::',:- .... o . , ....„ . ,..:.:: 6ived!:.:::.i..-: ::,... R ::;:',''':. ........•::::..':::• E...,?.,-i:N.V.:.,..:.:...-':'..::..........-11!:::::.::ii,..::..-.: • : •...: :.:•,,....., 6 t I op . - ..• ...•,... • ....-.••.,„..,-.„,.• . •:.• . . • • . .....:: : : : .. • ••• ' ' 1:. .......: ..:•. iil i 9 ::.:•: r o ot , ...:,.'.:;::;•'::::: .:".• - .....i.::iiii I '117f!,•::„:•::::::;:::.:i.::..::....„,.. :•:,i;iiiirOil■tiolng.,„!7..:,:•:::: ....,..:.• :,,.* Tr..„, . : .. . iiit°r:4)iiiiut ....!4t describing ati4.77 : ... :::: ,. :,.....,... :/, , ii „„..•.ii00...,..]?„„ NO ..:,:k990.-,:::,.:::::::.„,.,„i:;:::.„........... .,..„........,... ..„ the )11.'. .. . . .....,..".•:::i%. • . - :::::;;.•': . Piii TEP!! DIS HES 6ii iid111,..'-.".::::."'''":::•:':k:"';'..: :'...::•...... i........, .. • .:.,.,...:..;,:liii11..iii0r::::-::::!::::,'::.: ......,.....,.*!::.:::::ti'.::''''. Comp..... ,... . :tc our„t„..„:.:.::::.. In:...ct .. .... tiintep::::.....:.:::...:::::..........,i;.....„...... . .. ' . :...-elk:".."" ktc.,.:J.A:::::.. ....,,,,tiein::9.,...,:.:.:*:::,:::::i.,...,...--... .... ......;40,7.' tfa*!!ii i4cai;ii4.......-..: .., ii o.!i!..:tii:::1401!0i.i.;4110i#ii!....:iii.'iiii.....:-.:..otii°0 .:!1iii;;t!iii"°t7'.di1:.,..: ..:.!:'...'...•••••ii0!" ... Details , .• .... . 100:..... • , .' v ,.0/..... antenna/ fl ,Dat01.7- ..,,,..,:•.•.:,, . t . may be reau .... • • • • ofi:an . . aw, CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTIOW RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PERMIT NO. CO 3.C� PROJECT: t.,rvtA a mcvrt.._. 14`(2) SITE ADDRESS: / 67 a 6 ~. f , •- ,tiA_1, --) DATE CALLED: - / l - q f TYPE OF INSPECTION: r„ 4'rk.a , . DATE WANTED: - - /, - 9 / T SPECIAL INSTRUCTIONS: - --____ --- REQUESTER: -,Q. (�,,...> PHONE NO.: (9/ / -.. 57 R -7 INSPECTION RESULTS /COMMENTS: \SPECTOR: r UGC -3 DATE: ‘Q` Z :11 aw, CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTIOW RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: i, 0--* k_._ / J) i ,o. Z ' PERMIT NO. & 33 (, I DATE CALLED: l 'r' / (a `»- Q I SITE ADDRESS: J ,-. �- "Xi i _ .4, TYPE OF INSPECTION: l . + IE� o l , _ _ DATE WANTED: - i'i — q SPECIAL INSTRUCTIONS: REQUESTER: Gov,..) PHONE NO.: 4. ( -8 — 5 INSPECTION RESULTS /COMMENTS: PECTOR: �, DATE: /-/ 7- 9 / CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 .eerrx,vr:.+a.u+.sa INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: h.4. 1 1 ' / I I/ u ���5 P ERMIT NO. - =, ''%� %' -- 3,Ce q 1 Q om" , SITE ADDRESS: �Q�UO r //W 1 �� �/Vl S �1�.- 1 TYPE OF INSPECTION: PV' Ql,IN1,i' KO1 SPECIAL INSTRUCTIONS: i�-Gt � DATE CALLED: �' ( 5 DATE WANTED: (''yl (p '" REQUESTER: .1- PHONE NO.: r- 7x7 INSPECTION RESULTS /COMMENTS: _ . ..... r �,� ,,,, / i!1 L .:� .1 .i • ■ 4/ , ./ / / / Ai f , rr , / / rJ t INSPECTOR: / ,,,, „ 0 ���i1��/ DATE: / --/7-- 9/ CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 4314670 INSPECTIOIRECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 + a. City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Project Name Address . / . / , ; / – , S p r i n k l e r s : Fire Alarm: Hood & Duct: .Y Halon: ri' Monitor: Pre -Fire: / Permits: Authorized Signature , 1, TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Gary L. VanDusen, Mayor Control No. %� '" / Permit No. / 4' f, �/ Suite # _ Retain current inspection schedule -/ Needs shift inspection /Approved without correction notice _ Approved with correction notice issued / "- .? Date FINALAPP'.FRM T.F.D. Form F.P. 85 RIVER4'3EW PLAZA OFFICE PARK r SEERYL J. NORMAN Property Manager TECTON MANAGEMENT CORPORATION Suite 100 16300 Christensen Road Seattle, Washington 98188 CITY PARK I i ..,,..•f rr t rr •n���;rr�rr..�,i�tlr.:ri,.' A � trl ����l�•4, �Q r-. � • �� i:.... ...r • • DUI r ovis so m to Cs VErL . V a CHRISTENSER ROAD W m R E 206/241 -5787 206/241 -7512 FAX rrTY OF 11 IKWI A V� 4 Fok caws > �� l �vI1Q 1 I t inn d 'i,,,. H., ..„. ■ . �� ..., ■ . ate..... t +. AID k � RP,'(IYIO? 0 --= I N T<~K.)o rn G W 13 NTH DES FROM r ZoK - TD UNOEFZ 'SIDE cF NUN6 CE.ILII46 mum 54 st.it-I17 r- ; • GN I3 1 s4c 4 Pco ITT IIJS Ut_.. FROM rizoK `IU tiwoElcsice. OF 1-1IJNa-It_1N6. T E MPING- PTN 1 GW13 4 51t /CGUea"TIG OATT: INSUL rol-1 rizoic TO UI - ASIDE of NU► - IE; c,�I1 .. 1I-o° Wit BATT INSIJI cE4pcv R 11.A OJa c.I LII4 . m Vetp■cveA1- - Tyr 1 A % r- TAPt:. @ a) JP RAC PARTTT 01-1 morvin ataln a wociatos, Inc. planning and design Job 1 FLt ZA — thwikif1.At.Tltz GE1WI 1 . 4001% :TDd. Tls4A Warr-1z. -GO1JL L i 4 IA! ZOGA. TQAcK W/Z "10 SL1iE JS @ • L4"o.C. � Pt�1 r`IT bLA GK RECEIVED • CITY OF TUKWILA NOV 1 5 1990 PERMITCENTER . .• - -2'h , ZS GA. GAIN. STL. STUD @ 2'- o" o.C. . - L. BLANt(ET Q ONL`( 5 /b" FIRE RATED GYPSUM BOA2C (oNE Noun. CONSTRUCTION) A" RUl e AIC tSD a emgpeT 4e 6A cave, a V.La. GOVT, 25 4■.6i1LV, STL. RuNNe2 C.UMt EL - AvJCUoQz To Floot2 1 VDT raVA TAf G O A S rAlw r? TImaI4 a + C SECS lON ( BuiLDiN6 STD, PTA. TdI. .ANt2ARV }- YT ITtOM Job N139 Sh..l No 1 0.I. I•b• • acv 4.7•64Qj morvin otoIn • oacoclatos, Inc. planning and design ( Job Kvciwnv FTAz.6. :.rtit,t 445 leeWT - [1.1t 7 _ Mak . . Gt Ds*-' AWM1 lLL si/sti/isp-c) 1 t-It2AM - TAT::› otr e7ILL, t70 14ar. e..fcnk/ To SI 4zrot.11JP 1tiv4L ciNGINO se.4 0 54195 GF "TwIc I Lti eAcKet7 paw • IXIG MULL-4 T II la aRriTIOLI kAUWIGN (.014iq • Job NO6 Sh•411 No marvin atoln . aaaociatos, Inc. Planning and design Job RIVM/l c I RAJA • • '1. Wi-11 7.v ti u 2 L. c - 1 T 1-1"x. • VI -49 T C7a1 -41 Bt Ar --K - iAL €DEiE. (m m Effie-) tfrV I X ' vts • c+1 ?%' c xl, cic c ,-, Cc:W -1W Tal m014/AJu . ecI•1N. -,l.T. Job Nae/XYZ1-4 Shoo No . - GA 0.1. 1.21.51 1/2 Loll • • • . • • marvin stain t a;cociatos, Inc. planning and design - TYP1 OAK RE LITE .I AAMCCO . ohlwittoCrvonrs Fie au. GNapTEK 64 411D 4 EA 33o6 b. IwEt! AotapliG4HGE • T,11•1i? 046 iwTr✓ tV. Job RlVl:` -$ 'v1G1V RAIA Job N 1.4 Sh..I No Dote l'D•01■ • • ow OM TP 1/A 41 TE marvin ctoln 'YP asaoclntos, Inc. planning and design TM. ~ �A G,Lass 21i,L Job } M $IVItv 1?AZ. ► Job No6CO2i - 4Sb.It No to Dais 1.6-151- N �, .1A44 � RE. JAMS cal' OF WA I.1+ CG'. ! ) Nom 4 10 . 1 1)11G ,4L— t71 kA ).1 (ALA Jme? marvin ctoln ft' Till. F it U . ' Job NoQ72 I -4 .w No 1 ascoclatos, Inc. . planning and design Job 1 R AZA D.1.I.b.61 - • NN ti 0.6,K TRt0'' .'. • IS.1" " QsK OAK -rpm 1/4' P t 1 & ' : I • 0• • ' • t • i � i • marvin atoln • eaaoclntoa, Inc. planning and design • / J U! J 1 1 ! ;.1I• (, • 1I /s&" . 7 / • MA - 6 Tam 12r_.t -11 ki'.AP rI .1 t 1 /l 2. 7 �/ / / J' 4 Urn • Job No .Z!Z1.4$P..l Ho 12 Job gwarz,vicv R Oai.I•h•DI - • marvin stain ar *associates, Inc. planning and design GLAD BUT 1 OAK r R LJAMi3 Tsli. OA JA/At7 € GtAss, 1 r-ii 1 Job Nouav 2i •4sh..1 No Job f ive,f /ICAY RA2A osi.1.0• 81. marvin stein .P associates, inc. planning and design • • 4'• O" • • rr tOD K 4 V. Goo ryi . • f -Ame: K 4 V 7 EA. . - Vt. oAK 1 -YND. SHELF _ 4 SI bE • PAI -0-G , I it OAK t(1 ALL 60AT . Tills (. 7 AT GL.af Job KlV"=l<V1 q4/ pL,A2A • Dais 2.17. ,4. I I1 A'Ks' Job Nol.Z No 14 n10rvin attain I!! aacocicztos, Inc. • planning and design • I /d' Psats 6- pL&-r tARTIAL. HEI9HT....1✓'A '.TITION . .. To. . . ._... .T. 10,442 1 AL NT IAl21 Ilc. w.,.. N l: „.:...1 • • • mprvin. otoin lA. :. a ooc1atos, inc. planning and design > : rq5 Off, GAP o tr6Itx Cor.Nr. s De,&D NON -CAs t>. %IOW. It l. CAP- PAJ�T:. NI f�►I'IT111OM ` .joe ►a = = q 14.1 .jpb „�l1 Y "'” Iv A! : I t A 4 vvY •Lai.../. I� I • M; a! l 1 /4 1 ' Al2JL441" 6TANq raS-.- cAN et LILIe4c Easss 'M L . f=111. IN51 - u/�H bD atlAt . C 20 c,. . !` cg 1E° 2 Xi WD et I. • KJIJG. 0111p$ At. I41.161 6PAI. i 3 X11.1 MIN. Ns 2. MIL. RUC • 1 I,cV 6.1 B. • • -4 �--. ea.+. ten... • -- : c' z g.y.. w.v k Bt'4c oh0+- mss. CA @1 IJ c1" T,,,. CAI NET PM-TAIL- Joe NoI No-10 • • morvin otoln asaocIatos, Inc. planning and design . .ioo NveK1/ evv. p4424• cc-RI-Oslo •.I 1 1� �II }3J 1-16, • mi t m©rvin artotn ! ascociatos, inc. planning and design 1 /-- sr'C L&M. GuToUT pet 4 It j< 131M . c'c ct.. 2 - r 1 1 . 1 . ro E/6 OAK alg x4$ 1 F 11CL6 . W cAaluer E: ? - '. ALT mil. I - W44 11* 'p O2 , UARp�" .. sf>5i2. WEB SffCTIC 1 Till. CA13.1 t.../41E` Job.No J44'SI*.1 Job f 1 16$/ MA24- t3STAIL0.1. WINO L RADeua. "' IVe:Mi DTY6NTUK APPROVED' DEC 199() NG D /iSi f►y R .: : = f ?1.'.rc,._ L°T. - .rt ` t' No.. 'rye _.a !� (zxz) . 11' 11 I I Y 1ta_i%.: No wArroYom. Awl✓r::"... ya FII_ OPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of contractor's copy of approved plans acknowledged------ • sy..2 Date -qo Gdow7rke46 1 4 1 7 1 , 4541:: • 1� 44 $4 . 4261 CITY OF TUKWILA 6200 SOUTECENTER BOULEVARD, TUKWILA, WASHINGTON 98188 PHONE # (206) 433.1800 Plan Check #90 -473: Minuteman Press 16300 Christensen Rd #220 THE FOLLOWING COMMENTS APPLY TO AND BECOME RA'�� THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER l v . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277- 7272). 3. All mechanical work shall be under separate permit through the City of Tukwila. 4. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 5. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 6. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 7. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, .and material shall bear identification showing the fire performance rating thereof. 8. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). Gary L. VanDusen, Mayor Minuteman Press Page 2 .. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 X 7 Framing 431 -3670 8 Insulation 431 -3670 . X 9 Suspended Ceiling 431 -3670 X 10 Wall Board Fastening 431 -3670 11 12 13 X 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA BUILD(NG PERMIT INSPECTION RECORD Post with Building Permit In conspicuous place) Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 16300 Christensen Rd SUITE NO.: 220 BUILDING (o3 f_ PERMIT NO. K� DATE ISSUED: J QLt T CfQ PROJECT: Minuteman Press CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or If underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 'X' REQUIRED INSPECTIONS 1 Footings 2 Foundation 3 Slab and/or Slab Insulation 4 Shear Wall Nailing 5 Roof Sheathing Nailing 6 Masonry Chimney X s 7 Framing 8 Insulation 9 Suspended Ceiling V10 Wall Board Fastening 11 12 13 14 FIRE FINAL Inap: 15 PLANNING FINAL 16 PUBLIC WORKS FINAL )<17 BUILDING FINAL PLAN CHECK • NUMBER cr0- 473 (SROJECT: THE FOLLOWINS COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER Na changes will be cads to the plans unless approved by the Architect and the Tukwila Building Division. ( 2) Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 47321. Electrical permit shall be obtained through the Washington State 1.; 172,// Division of Labor and Industries and all electrical work will be inspected by that agency (812- 63631. O U 7 All structural concrete to be special inspected (Sec. 306, UPC). O All structural welding to be done by W.A.$.0. certified welder and special inspected (Sec. 306, USC1. �9 All high - strength bolting to be special inspected (Sec. 306, USC1, tS 16 All mechanical work shall be under separate permit through the ity of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. Any new ceiling grid and light fixture Installation is required to melt lateral bracing requirements for Seismic lone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (51 feet in length. 12 Readily accessible access to roof counted equipment is required. 13 Engineereed truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Pr fissional Engineer. Oa Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure.). A statement from the roofing contractor verifying fire retardancy of roof Witt be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and 1.R requirements of the Uniform Ouiiding Code (1959 Edition), Uniform Mechanical Code (1985 Edition), Washignton State Energy Code (1989 Edition /, and Washington Stag Regulations for Barrier Free Facility (1919 Edition/. 18 All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4717, at least three working days prior to desire inspection date. On work requiring Health Department approval, it Is the contractor's responsibility to have a set of plans approved by that agency on the job site. l9 Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20 Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21 All spray applied fireproofing as required by U.B.C. Standard No. 43 -1, shall be special inspected. a All wood to remain in placed concrete shall be treated wood. 23 All structural masonry shall be special inspected per U.I.C. Section 306 (al 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Fire Department Review Control Number 90 -473 (512) Dear Sir: City Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor November 30, 1990 Re: Minuteman Press - 16300 Christensen Road, Suite #220 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel to any fire extinguisher must be 75' or. less. (NFPA 10, 3 -1.1) (UFC 10 -1 (3 -1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.6), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.301) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exit hardware and marking must meet the requirements I . ` . City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 Gary L. VanDusen, Mayor of Uniform Fire Code Sections 12.104 & 10.402(a). Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFC 12.107(a)(b)) 3. All modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) (NFPA 13, 1 -9.1) (UFC 10.307) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4-1.1.1) (UFC 10.302) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1 -10.2) (UFC 10.305(b)) 4. All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEC 70) (UFC 85.101) City cif Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number Yours truly, SKs�Z The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd Gary L. VanDusen, Mayor All electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (NEC 70) 5. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers . shall contrast with their background. (UFC 10.208) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Plan Review PROJECT ADDRESS f( C4-Ie.ISTEN6E.1-1 ?i , • ZZC2 DATE Z 1.1OV. ( 10 OCCUPANCY GROUP .- ES 2 6 TYPE OF CONSTRUCTION LOCATION ON PROPERTY � I U G ✓ `UIa „ a. ) E BUILDING HT. / NO. STORIES . i?- `- FLOOR AREA -O4Pt ° c E i t O OCCUPANT LOAD (0/1 = NOTES: Or EXITING REQUIREMENTS_._,_QNC. E)(it P. V DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.C. W.S.E.C. CHAPTER 51 -10, W.A.C A CITY OF TUKWILA DEPARTMENT OF COMMUNITY DEVIL(' "IfENT PL NNN: DIVISION 10 [ LAN CHECK NUMBER 0 -473 prepared by: • i row TAPE i• x xci -arts woo su - SAM TO FAQ DETAIL #1 x 1/d' roA>r TAPE AT ` Afo r VARIAN PARTITON TYPES; i/$ TWAT tom_ PTPI 1411W= Qf IRa4t1 CtIB+rl 3/3 SCAM •MT WSIJI,. cu.1y4 7 c UM c &ATn NSW MAI 110011 10 LICOSIX EV 1111110 MAC. . n am tt_,ITETaa ova minctl1 441MG MAO SEC JON BLDG • SUSPENDED CEILING SUPPORT - DATA ' Lateral support shall be provided by four wires of min. 12 U.S. gauge splayed in four directions, 90 apart and connected to the main runner within 2" of the cross runner and to the structure above at an angle not exceeding 4:;" frow the plane of tine ceiling. These lateral supports shall be placed 12' - 0" o.c. in each direction, with the first point within 4' -- 0" from each wall.. Vertical •supports shall be No. 8 U.S gauge wire to support a max. • 16 aq. ft. of ceiling and saddle -tied around main runners, per chapter 47.1812 UBC standards. 'Cross runners attached to Vain runners by saddle -tying with one strand No. 16 U.S. gauge tie wire, or approved equivalent, per chapter 47e1812 •UBC standards. Discontinuous ends of cross - runners and main runners to be vertically supported within 8" of such discontinuities as may occur where ceiling is interrupted by a wall. nu.. 1 : 16 3 3/4' SEE OET. g t• 2 1/r $ CA. CA1V. STEW. OM 9 33 ac. r • ( D op OILY e . ... . _-4 _.._.a__"_..._ 1 iltrei u r i 1 1 _ A II ��I ...,... , -,, .. .... ...., 1 ...... ,,,,iiv iiia". 0 Mi ce I ✓e f I Lo 'I 1111TH1111z( 11 /1alllll /11. TENANT kt4E . /ITCH r A TiS1Y'1 f 1 =-- -- - - -• UP- Co RA I=..r.: TG' bEM1 • F'TI4 ., 3/S TlE'E Y p9t b OMPIELS • RATS Silk. If® t. ACP= PAIli3$ 4 Ml RAIL IOU SAT' roes' as eoTl, aaa Or 3 1/r MET* SAM s,�e�oa I-AC. Me CAL -CU `tint- ; CIh11NClo S (j) . rwourC . L7, P x ., ; ( 4 r - ORRI -DOR CE {41NG 11 (I „it MOM It) i 1` 2'7 mut 12'' r g f�rc ,"TO 0..„6 =4::" C..ta a111 JIII11111 lt - II11I7”UUn ' TENANT UOSTS PRQtECTIn rr 1 -I{*. CST. • r1t1E 3a0,81 M! Kat t >f"--'T1' SOLI �S N , I T I Ti Ala UrGIe..Pt. OiStA I .I ate,, 14o1; !-1vAG - w /!ta. I' " l .e,ie . 64)44..414 1? tri HAr.sem late PJIt ,i:� CA V. vo 42. (1.A'j512,&E. u PPo( -rT6). 1 ti \ . , IzG. WPs Tf aN 1• -1g... ''e D1•!7'?,� Ytre NI tn/ 6L4 ' I�f• 40.1.161 61.1.404-41249 }.tire zh a tz. •f) -,a to. G. (VERTIe#AIS bLJPPPrrre -r$ = C2:41) LZ 9Z S 4 7Z CZ ZZ J 6Z 8G Illnll�!! u11�11{ 1�II! nl���!!► III lllflll illl llllllillllllll !i ►I!!i;;II;,IIII i , M .5 ,. t • •' I _T. • L.IG t-. r P oc ru p.L° !l-Ae-4 6" UNLESS OTHERVASE' NOTED u -- CIO =-- - . - =r _.14.14,0 1 . ft il,of.S.UGE alb°t-N /Ar- 417...aQ -•._, HANC3;ag V4A MEE W/ THR MAIN XtJN1-402. Tea 1 W 1-11.4N61 G E I L I N c i D6OR NUMBER .TYPE OF DOOR A • ----7 4L.. Ny h •G. Q4$ 512,K K It-.1 weo a4.KC, f! . 20 MIN. LAn... t5) rKAMt C . AI iZ Off_ L(o" x w fj 2• GI X to e II a I PC, HARDWARE 0. B/S LOCKStT & CLOSER b. e/S LATCHSET Ce , r ''S 4.01,11711.1 MP. • Coo GR, '14)112,: B/S WALL MTD. DUPLEX ELECTRICAL OUTLET Om WALL MTD. SEPARATE CIRCUIT — 120V., 20k (W/ TIMER) r - fola v.. L I N I'r. ) }� �I B/S WALL MTD. TELEPHONE OUTLET (WALL PHONE 0 +54" A.F.F.) >a 11041 e-"fitJCt. • NOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the original document. tZ oz 61 81 Lt 91 St hl CT 2 l it 01. 6 8 L 9 S *, E z l raw Q !! i! I!! IIIiIIIIIIlll! 11111II1111111 !IlIIIIl11I!Illlllllilli I I il! IIIIIII l111111111111111 !IIIIfIIII ►11 f'1+ III !! ' I �I I 1 I 1 111111 : , 1 , „ i , l!!1 . !!!1 11111111111! 111„ 11111TH. iIIIIIIIII11 ,1111111111111111111i111111h1 ! . -� �,r•�t -1 r,a„r -� ra - T� v iz t -f w/ t i∎IT ' - t -' we.-rA l.144 -Ti ch4 . ELECTRICAL L and TELEPHONE ' LEGEND { v KA- B/S WALL UGHTSWITCH t _ 2ND FLOOR PLAN! SOUTH WING I .- j B/S 2' —O" X 4'--0" RECESSE I . FLUORESCENT LIGHT FIXTURE _..M_ r . 1 i :! `.� �r I er r i-Aw1 `< , .1 fsa IT I`l�jj > EPARATE PERMIT AND APPROVAL REQUIRED By Date understand that the Plan Check approvals ubIect to errors and omissions and avpro+ri9, of plans does not authorize the violation Of thy adopted code or ordinance. Receipt of d46t9friktOrs copy of approv • . , s adWOwt lt*d. , I' rmit No 121,1. A Rt'm. i i FILE COPY I . /-1f' —• ' G4L ECN4NIe4 L 710 , t~T' t"• -RI o ./ lfl l t4I- - rIJl. 44 p' A ; 1 ?O' -i ',f r \'vl L,.4. WA O 0 A CITY OF TUKVilL APPROVED; DEC, 3 1990 B(. DID4sQ(•i CONSTRUCTION LEGEND B/S CORRIDOR PARTITION - ONE HOUR RATED (m)41. - rit4 ..) , B/S TENANT INTERIOR PARTITION: 2 1/2" METAL STUDS W/ 5/8" GWB EACH SIDE FROM FLOOR TO UNDERSIDE OF HUNG CEILING. B/S TENANT DEMISING PARTITION: 2 1/2" METAL STUDS W/ 5/8" GWB EACH SIDE FROM FLOOR TO UNDERSIDE OF HUNG CEILING - PROViDE ACOUSTIC BATT iNSUL. BETWEEN STUDS; CONTINUOUS, & 4' - 0' WIDE ACOUSTIC BATT INSUL CENTERED OVER PARTITION ABOVE HUNG CEILING. ; t:>C N, - r - F:1c rA t' `7111 *1 T<' c !!!,' B/S COAT ROD & HAT SHQF DOOR SCHEDULE LIGH11NG LEGEND a� r . . • GENERAL NOTES • ey Nen flECEIVED NOV 1 5 190 PERMITCEIIiTER 6,6 • CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN CONTRACT DRAWINGS & SPECIFICATIONS FOR BUILDING. 3 CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITION$ AND NOTIFY tv(S& OF ANY DISCREPANCIES BEFORE PROCEEDING WITH ,WORK:` 4. 8/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD DRAWN AND/OR SPECIFIED IN BUILDING" CONTRACT DOCUMENTS. 5. BY L.L.OT.E. INDICATES "BY LANDLORD AT TE !ANT'S EXPENSE DIMENSIONS TO AND OF ELECTRICAL & TELEP ONE OUTLETS INDICATES MAXIMUM OF 6" FROM CENTERLINE 6. ELECTICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 7. A.F.F. INDICATES "ABOVE FINISH FLOOR ". 6 CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS J - 'WALLS AND CEILINGS TO aE INDEPENDENTLY SUPPORTED, • FOR SEISMIC CONDITIONS, IN BUILDING JURISDICTIONS • WHERE APPLICABLE. DATE CJ REVISION! 1 0 .- l j ■ ct 5 6 3 • - 1 • • f a • 3 ..I 0 Ca) • I G arnam c azimm 0 a_ cacIV N ° CO ,7.1 L(31.. isi � an an -ill::;;!! . CC s" :�be Clt 'Fi Ca a Wow a Tics > e Len w co e C11)›usse Z . W c FE C Cr \ 10.24.Tr..a 3Cal.E • PRAWN ' 1' J00 . - t SHEET , OF I SHEETS •I . .1 • • 4 r I •, • 1 N4 0 f aTA•011WT STOCKITAA WTI "a P4 NI 140. ,„ -,a %A," T"ACING VIII VYI al '011W NQ. Tel "I 1/ a a there I Q",QI '- „ r Ir