Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 6339 - JPS Carpet Corp - Stevens Carpets
PROPERTY OWNER Southcenter South Assoc. //2 PHONE 57 - 3025 ADDRESS 20206 72nd Avenue South, Kent, WA I- 98012 CONTRACTOR Wazly - D. Co., Inc. PHONE 854 -6420 ADDRESS P.O. Box 5697, Kent, WA ZIP 98064 WA. ST. CONTRACTOR'S LICENSE # WEZLYDC142B8 EXP. DATE 1 - 28 - 91 ARCHITECT Rupert Engineering, Inc. PHONE 833 -9776 ADDRESS 1501 West Valley North #101, Auburn, WA ZIP 98071 USE ..� DATE: APPROVED FOR %Au ISSUANCE BY: /%, . d. / � �� t (, FLOOR SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD TOTAL I 'P SF • B •, year : N/A 1988 SETBACKS: N- S— E- W- UTILITY REQUIRED? Yes g O a) No Public workB� FIRE PROTECTION: DX S rinklers De tectors p O O wA ZONING: BAR /LAND USE CONDITIONS? O Yes ® No CONDITIONS (other than those noted on or attached to permit/plans) A. BUILDING OFFICIAL DATE: APPROVED FOR %Au ISSUANCE BY: /%, . d. / � �� t (, CITY OF TUKWILA Dept. of Community Development- Building 6300 Southcenter Boulevard, Tukwila. WA (206) 431 -3670 BUILDING PERMIT NO DATE ISSUED: Lc73 9 SIT SIGNATUR S PROJECTNAME/TENANT JPS Carpet Corp. CERTIFICATE OF OCCUPANCY NO. 18437 Cascade Av /2't Division 98188 Assemble and install carpet storage racks. BUILDII3 PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) MEE •1 *1-1 ;1Ia BUILDING PERMIT FEE PLAN.CHECK FEE BUILDING SURCHARGE': III' 11E T .i'i► i 111111 ISINL 44.96 4: 50' 49.46 3529`;! , 15 . 490 , PLAN CHECK NO.: 90 -474 5,535.00 ASSESSOR ACCOUNT # 788890- 0040 -05 TYPE OF O New Building Addition Tenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: © Rack Storage O Reroof 0 Remodel (residential) 0 Other: DESCRIBE WORK TO BE DONE: I hereby certify that I have read and e amined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructi_or the performance of work. I am authorized to sign for and obtain this building permit. DATE: This permit shall become null and void if the work i not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DATE ISSUED: 0 PERMIT NO. CONTACTED c 1 O DATE READY DATE NOTIFIED i l L�- L7 BY: (Inft. ,.....se PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING ,, 3RD NOTIFICATION BY: Inft. * BUILDING�ERMIT APPLICATION TRACKING PROJECT ef7 C Y (p C or . SUITE NO. SITE ADDRESS 1 '645-1 C.O cur) Q_ f N s PLAN CHECK NUMBER 0- L1 LI INSTRUCTIONS TO STAFF • Contacts with applicants or requests for Information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) • SQUARE OCC. FEET LOAD . SQUARE OCC. FEET LOAD SQUARE OCC. FEET LOAD SQUARE OCC. FEET LOAD • SQUARE OCC. FEET LOAD TOTAL SQUARE FEET TOTAL OCC, LOAD DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project. RE UIREM _......._... PAR: t`lVM BUILDING - initial review FIRE O PLANNING O PUBLIC WORKS O OTHER BUILDING - final review 11 - 90 t ► - -9'0 Jr REVIEW COMPLETED it -z7 -c1O INIT: INIT: INIT: INIT: NS LT ROUTED i + 71 /q° FIRE PROTECTION: Sprfnk era Detectors N/A FIRE DEPT. LETTER DATED: //-9c/-14) INSPECTOR: 60_ INIT: `a� REFERENCE FILE NOS,: ent ZONING: IBAR&AND USE CONDITIONS? ( Yes MINIMUM SETBACKS: N- S- UfiILITY PERMITS REQUIRED? O Yes PUBLIC WORKS LETTER DATED: / 4 _ 9 - TYPE OF CONSTRUCTION: (4ck o74 0 at UBC EDITION (year): lcISO w- CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 APP!.ICA TION It1LJ ; 1 III Eill ED OUT C011iPI 111 1 Y BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE PRINT N James W. DATE APPLICATION ACCEPTED 6/ La . ADD`R SS 6841 So. 190th St. BUILDINJ PERMIT APPLICATION DESCRIPTION BUILDING PERMIT FEE PLAN :CHECK FEE McKay BUILDING SURCHARGE SITE ADDRESS 18437 Cascade Ave. South SUITE # PROJECT NAME/TENANT JPS Carpet Corp. (Stevens Carpets) VALUE OF CONSTRUCTION - $ $5,535.00 ASSESSOR ACCOUNT # ) 766 elc_Qc 1, fo - - e U Tenant Improvement (commercial) ❑ Demolition (building) ❑ Remodel (residential) ❑ Other: TYPE OF U New Building U Addition WORK: f Rack Storage 0 Reroof DESCRIBE WORK TO BE DONE: Assemble and install Carpet Storage Racks BUILDING USE (office, warehouse, etc.) Warehouse NATURE OF BUSINESS: Wholesale of Carpeting WILL THERE BE A CHANGE IN USE? ( No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE = = = uilding: 60 yh/Q enant Space :00 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No ❑ Yes IF YES, EXPLAIN: Area of Construction: ez.1,ix as PROPERTY OWNER Southcenter South Assoc. #2 (Pemburk Mng.) ADDRESS 20206 72nd Ave. South, Kent, WA WA. ST. CONTRACTOR'S LICENSE # WEZLYDC142B8 ARCHITECT Rupert Engineering, Inc. PHONE 575 - 3025 PHONE 833 - 9776 ADDRESS 1501 West Valley N. #101, Auburn, WA ZIP 98032 CONTRACTOR Wazly -• D. Co., Inc. ADDRESS P.O. Box 5697 , Kent, WA PHONE 854 - 6420 ZIP98064 EXP. DATE �r - i / za / ZIP 98071 DATE 11/7/90 PHONE 2'1 -66O0 CITY /ZIP Kent, 98032 CONTACT PERSON Jim McKa or Dick Witt PHONE 1 - 800 - 869 - 2727 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Comm""r'•;„ •^. rrlor to.epri!^^•'°- . -"' -- "" '.. ^• -^' thn Permit Coordinator at 431 - 3670 prior to submitting appiicsa,ni. In all 4a000, a valuai:on amowil .71Nuk b6 entaie i ur the applicant. This iigui will b6 reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431-3670. DATE APPLICATION EXPIRES 3H5) o7, • • • COMMERCIAL " " • • : • ' ' • •.• • NEW.00iIMERCIAL BUILDIN439/ACIDIT10 10 ' • • •••::.••••••, • •••• •••.' •••.. ••• '••••.• • •••. • ••. •••• L i Completed building permit application (one tor each ...• . . • •• . • E Aussor Ariootint Nuinber': • •••••:,',':::•.:•••".:' •••:••* • • s : • • • '' ' ' ' calciilationa starriped•by ..„„ .....„. .................. ....••• Ei.$6111 report. stamped by ar:Washingtoei.StateliCensedengliteerf:-.:••::..,.• ................................................................................................... •••••• • ••••••••••••••••••••••••• . ....... „ Washington ..‘ • • • engineer or wthtect E dscdp? :ton. ttao: • drawinge, Iltf4n Woitin • Which Include: • • • • • • „ . . • . • • '.• • • • • • ' • • • • . . • „ • • "•••: ••• ••••• • ::. •••• • •••:,,••• •• • ••• :•••:••■ Site plan ....... . . • ••• •••• A1°11114°01 dri • • • •• :••:•••••••••••.• •:,•:•••••••••••• • • Ftleititnical dra*inger.... • • • Ekwatfons •. • • •• . .... . Completed ubiity permit application (onefOr•eritira pro • . •••••,.. . •:•,;••• 310(8) tiannIt appllcatlon and .. ..Ftitqc•s : ToRAGE • Completed ...... . • ••.••• ". • " • :." •••••••.• . . • . building • •• Assessor ACcrititit • • :::••:::Tvi.a(2) 'llets of Buflding flcor plan showing '•••:•-'••••• ••• ."••:•"•':',•••:::.■ • Eiji doors • ••••• ::::•••••:•"•••'••• • Ten ant ipace fleorPlart'Inb*ing rtscitstortsge layout aiSieeien • • • . . NOTE: CAtakinsioits:..0/. ni andk 810:lottoral• CilOulations.itainPed,b0;e:Wesningtiel.*tetalkense •ngineer RESIDENTIAL ---- • , • '• • • 5ets • of th ° I r I g ::: ' ••••• ••• ••• •••• •••, ••••• • **: ica Vogt . • : Carripieled bUIkIno permit Legal description • • • • E Aasessor Account fl Two sate (2) of **icing draWinge;vfilckinCI • ''''•:•-•• ......••••• • • • .-.. .. • •. •• • • • • ! titan' .:••••,• •": ':•• • •• ••• •••• • • • • • . •• • FoUndstion Oen .. • • •••,:. • BuidIng elevations (all . .. ! Building • SOuctund.traming plans • SUBMITTAL CHECKLIST • • • • • • • • ••• ••• ••• • • •••••• • " • • . „ • DENTIA •'• • • 1 • • • • " • • • • • • • ••••• and method at SUOJr • on Sta te • fl�ns ••• . . .....: • • • • • ••••••4!.+84elIOk. 0 • • • • •••:••••:••••'•• ........ . . 7Pi• !rip Iioa iitid • Oti • • • , • . fl Assessor Aocount Number wo (2) sets of plans which nch $4i. Pian (showing bufldeg and o:otot.00*o...4044:44 ."" ................. Numbe Twa (2) sets 01 king si.„1,g • . . .‘. • FF3I9IP44 f;•fl iiiOrta• , .:(aii ".• •:. .. •••:•••• sws TO: PROM: OATS: SUSJSCT: Cityr of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (20S) 4334800 Gary L. VanDusen, Mayor . 5h..P 11 Boz c)u rnb-er I") / qqo ac‹. r - (IPS Car p-e - Cor )0 x a. = coo )0 Gino 10 11 LI = L I (-to II x1 'ND Lilco MEMORANDUM (10 /T2.MEMO) 5vr Char age., T - r - Cd • 1 00 1 _O h 1 A A 2. itIM. rra.r..2 n..7-7,S30 •-• Wer 71••••••=, mom.sas A •:;,. r')NfZ's 4.1■••.....1.11 amp.$11•■•••••■•••••111[70. 121 1%2, k 2-4 I I I / I pI I / / I I I I / ■ POCK LiAtv ■ AR rr. 1 . • • • i understand that the Plan Check approvals we subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of contractor's copy of approved lens acknowledged. . . . , . . . . . . . . . , . . . . .. . . . . .. . . . . . . . . . . .. , . , . . • ....'. . . - . . . . . . . , . . . .. . . . . . . .. . , . ril'ii,, . .4 .i.'.4t1-','/,''f,..'''6,4:.e.,,,,,c,..".i'...,,....,`.',..+1;',.•:: ,,,,,. ...T.'5:-.,*-,P.tii.",!';0•;.:,,..:;,...,.,;'.....'..:;.','.4.'4';.4',,i,"..',,,;,,..,;,'.'2','`,..,1a.,,,.; '''.•....,‘ ',: ..':., • '.: ,, ,- ,. .• , ....',.! ' :.,.11,.''.'i'!-,,,,10.,-..:',.4":::•.,' .... ... . ‘ • .• . , . , ' .. . , . . , . . (.7.',. . . . . .. . . .. kr. CITY OF TUKWILA - A P P R O V E D D •bE '1990 • • . • ' • **‘ ;Co .4 •••• ■••••••••• • • 4. • **/ :•!••' i:Ac nffICV 1415 111 RECEIVED CITY OF TUKWIIA NOV 151590 PERMITCENTER , I0p 1_ p „ AkfA 2 -- :J=une :as x r L•OOR P1, • SC . .. ��ib (.. Ci • / / / / / / / POCK 2.4 / / / / / / / • / :�E w .._ _ _ _ .:� _ ' tom -----► y_ ...-1=7:-.1, . -.r:= cam. M w ...me • r•....• ••w MN wc1 ,..,..•••.ww www.n,,...,... • • i'Y.. .•�••. • AREA, I, 1 adopted code or ordinance: Receipt of contractors copy of approved ions acknowledged. Date r t\ . 4. . • — 43.4b1'..0 • it ui3TC: • . 0 \ I Lc) RAC• , P E.' T'A I ! . AREA 6C A.Lia, CITY OF TUKWILA: APPROVED 1990 10/23/90 14/33 ( STEUENS ABERD I . iI I ':I i f 1.1" 1 11 11 CONSULTING ENGINEERS /CIVIL AND STRUCTURAL October 15, 1990 J. P. Stevens Corp. P. O. Box A Aberdeen, NC 28315 ATTN: Mr. Dick Witt RE: Seismic Anchoring Tukwila, WA (R.E Dear Mr. Witt: CITY OF TUKWILA . APPROVED N0. (?i 2 3 002 CITY O TUKWILA NOV 1 5 1990 PERMITCENTER Re: 'DETAILS ARAGhlED Fo1Z BASE oi• ANCi4Or for Storage Racking for J. P Stevens., Job No 9010 -218) Inspection of the storage racks at the above location revealed one basic geometry and loading condition. This situation is illustrated on sheet one of five of the seismic analysis. Calculations to determine adequate anchorage and the required base plate size were performed based on the site information that you provided and this loading condition. Under the various load cases, it has been found that this racking requires attachment per sheet five of five of the seismic' analysis to resist overturning forces due to seismic loadings per tho 1988 UBC Standards. Please contact me if you have any questions. Sincerely, RUPERT ENGINEERING, INC. J F� E COPY Jay "Bonzett, EIT I understand that the Plan Check approvals are 7RB /mh subject to errors and omissions and approval'af AttaChrifIafl s does not authorize the violation of ,any adopted code or ordinance. Raceipt of controcto"r's copy of approved plans acknowledged. Date Permit No 1501 West Valley Highway North/Suits 101 Ca.. 09C /A. .L..... IAA AGMI. 10/23/90 14:34 STEVENS ABERDEEN RUPERT ENGINEERING, INC. 1501 W. Valley Highway N. Ste. 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833-7776 FAX (206) 939-2168 , • ., SO I • • 4 0 I e....e.r hdl. 14.. .....,.t “.. :............ . . • ! .......‘^orait)r.,.. ... ,• I i • , . .. Ct I i t I I 16 I awn••••• &redo/ • ••..•••..... .", •._•••.. • 111 • •• • C-- ... • ...... • I., 101 ••••• • •• ••• •I • /, 44 01 LAIL • Oft. 61 s.14 rovve T._ Zr7__ • 0 r r NI I tc.c.01. p VE. 1 1 ! .1 ve.il : •rte,^1..; c.reo.n)s 1 Z. 94 - ()-3 WM ..... . . . • • 4m4 10 4•1 IP • • • • • • • • • • d•••141•1•1 •••••••• ....,.,77,;.‘f......... I i 1 I : • ' z . i •••■••• O. .aar,s0A!..0.01, ,...„7 1.40 hie W.I. .1,1•10 ••• .41.1 ••••• JOB 9D t) SHEET NO. CALCULATED BY CHECKED BY sCALF ""... ... - — g.(4.444/Af.‘• . , • ..... N11023 _ • ■Li IL 003 •••••••••••• or DATE DATE 410 • • , I I I • 1.i14.11 1••0111111 .... "1.1, rt /0 ••••■••11.1 01.6.0f. • ....... 10/23/90 14:35 STEUENS ABERDEEN NO. 02.3 A' 1' 1 110 RUPERT ENGINEERING, INC. 1501 W. Valley Highway N. Ste. 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833.7776 FAX (206) 939.2168 • o NC_ r .1.4.041/1 44 ...a 1. l- Joe SHEET NO. 2 " OF CALCu$.ATEO BY �'g DATE 1 OP/ 9 Q CHECKED BY— - -- - DATE. SCALE _ OW 0 K .141410 MN �..._... , 1111... • .. i ... ....... .. .... ......._.._ . , ••• ....fkor c !..r„) ....t..F:A. Li.: . w. V A IG.r4t• Los, . adoic.t. �1... 1,.r Y 1 -s". ? 3. - ... ./..,�3 )1G.' 4zci. _ ,. �f':.`l.#..._.,............ ' ) ..1. j . or . N►C�T7 : oA1.`; , .... i ... _`._... ..._.... _ _....... ,, : 1ftf:A -T.,. Look*, ._..- .. , g4r4 %.R' - 1 . 2: �f3 � 01#& ....n........ __,..._.. j ...... � !.____ .. 1,. r 1 3 1'?tl;t -_ .t2E.�,c�YI:D. 5....;.._ ... ...... __ .._- ... a.., ' . � K . . I 1,.7µ . :_ ate - - - -- .. g. .' i 4.95.. * 1.,: 4__....L `.... .,., ; ...,I.. 4 . , 1 .ta ".' ... .7 ±.. I d .... J�D. L �,... _._.. .._._ •. _. _ ___,.... 11.40 ...._... ••••• ..... 0 1..1 .01 ... ( 9o/A - 2)1 • 004 „a rrer.v.e I le • i f r _ ...�.._... ......_._a...�..�._ 1 Lem 10'23!90 •!4: S6 STEUCiiS AE�ERDEEN RUPERT ENGINEERING, INC. 1501 W. Valley Highway N. Ste, 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833.7776 FAX f2d i 939.2168 oe SHEET NO.... NO.0 005 A /o — �$ CALCULATED BY _ A _ _ _ , DATE ./9/4 /1°0 CHECKED BY - DATE _ .., •..._.... ( H a , ' 3 . "" 'b ............... , ..,� . �. -re 11 � ""'i•... •.. •.,,.. _ P j _ 1 h.. ( �. i 1111 ., ....r ....� ^ ....,, 1 � r.,s � 1111 _./ Z ,,.... 1111. 11_11._ ' . ,. ?' � . � L ; �vC,t�C. ».,..;........_..._ : .......,_.__1:y J .. :, . r .. JL ` . . 7. - r �. . ,�.. '• ,.. - ... � ;......._. __ ........... x. .,._ «111.1... .. ... �_.., ..... »..._ ............ .,...,........•�,....... �_..... _..- ,...._...�.- ... .,. 1.7,.. 11 _.,....... .�. �c,. x..0 ..• , !mac _1111.. ._.,.,....• }� ».. - -._ . _.w. ..... __. , i - -1111. _._,..._, , ... • 11. .,•..........,__ .,_!1.4 ..• 1_111 , ,....,_.._ ^., •,....,....._........,.,.,• 11» ..,..•,......._._.............. . ... ,.,•.. 1111_ V _1111 111.1._ _.._._.....,. .. .,..._.._ ,_ , : :: 1111 ' -, . «.......,.....__. _..............._ ._....,.,,...,... _..,....,,..,.....: T_ »w«,,.._............., _............., .....,.,, ..,..,...._..._..._._.. ........ _...�_ fl7 , .. l � _1111' .. ; ._..a._... :...... ..I:._._..„ c....._Go. .� .. ..._ _�._.._... !......•.....,.._. ._ ._......._ »_1111_ ,........., 1 7 ...Z ._ ,.. 111, ..._ . .., ••....... ..,,,..... _•...,..., • ,.. , • .., 1111.. ! .......Mti o.r... ..1• ,._. .F'►..... .. .., ! ,.. .. , »..._! .._.. .,....._ .,,_...,._„ 1111,, •. .. 1111. , i .. � • . 1111., .._�, _ :,.,w.. 1111_ � ._..1..,. 1111.._, .t��..,. ...• .,«.......... .. •... , h .... _•.._; . ,.....1,..t; 1111 ....;._....., _J•I.,i:,, .,.,. . .. ~',. _., 1 .. . 1111,, ,.. _ ,.,,... ._...�. _... __ _..•..,... sa a ..,_, Ail ,,,,.... -- - -- ••• ,V.Ai-.r � lg .. ... ._ . • 1111• ._. __......,.• .._.._... •._....,..• _. -- ...,.,,....__ . Itf .w _ 1 ...... , _ ....._.....,,.., , ... __ _.. ............... _...._• _.. . .,e , •_... -_,. 1111.,. 1.111. 1.111. v w ...... ...._.... . .1. .. __......... .._..,._....,._..... .. _ --- .,.... 1111.._ ..__ :. ±_ :11 _ .., i _...,........._..... ....._.... _.. ...._�__..__. -._ • - 1.. 1 « 1 111.. 1.,. �.- _._•_ .».._..__....,.... ___. ., _.., _...- __.......•. ,..........y.�. ._..._... __ � ._w _. _........... 1111., ...._Q.:�_..._..... �.,._.... 1111 , 1111,,. . 1111•. _1111._ ...:....'.........._. ..._._... 1„.. , • ._........._ •_.._ 1.1.11_. ,, ». _............. .........,•..........._........ _1111, _.» .,w.... _ , ........_.._ ...._.._.... • 1111•_. ,,. I. ..,._...... � ..�,_..._ , ^ .. » a _._. ,n..+..,,... �. � .•.._. _.._ ............ 1.111.., .,, . ,..................: . •..- rv......._ 11.1.1..•. 1111... :,. � ...., 1111.».. . • „�►..:...R. ... „ 11.... ' _ :1111 _ _ 1.111. ...._._ 1111» +........_ ....... _._.. :.• -11 _1.111, 1111. __ _._.. :..,•,•,.._..•._.._.._ _.�,.__ ..._.......... ....w __ ......____� 1111_ 11 - -- ,w._. ._n ..., ,. ».,.Q 1111.•..• ,... _._._ -, -•1111 ...__ ... ._.....,..._. _.._._ _11__1.1.. 1.111 11.11.. 1111. .. -;.� t --- 1111.., _ _ 1111.. r .._ . •.., ... 1111. ., .. ......_....psu, 1 11.1.1. _..:._ _ •_ 1111 ••• _.. • ....,....._.. 11 .. 1. .. .. , ,., - _ !A�v .r ••••••• ......... • __ y .. -, j ` 1 /2- •wlar_......3..7�'". 1 A . .. ..,� � . , k� • .. e' 1 , j.., . 1104,01 1.......___ ir ,hx._ . •.. } "..`.... 1111.. s... t_. } ... _... _.. ...... „ .., . 7 c:../ S .1.. /..• • , 6 .:..t. ........ • .._-- kW* • ... :::.. .,. i + 1111 1 . • . ._ 1:•111_.._ . /' fT. r .C..qr. i ; ...._.�.....:•.. I i ,_ ..;. i 3 . _: iQ _.... ..7 �, ..� _._.....� 3. i 1111 �.... , ' i 1111. irtstr .G r —-- •... ... _ ... • _._ . 1111...__ �R..� 7,.. . _. _._1`_11 _.1. ..�..: �., _�. - - _ � .1.�. _ '' ___ _1111..• { - . `.1i4._. 1__.. _.• _. .. ...1.�e�'l.'{7` • .._ «• .._ _ . -- ... .ft, , I .!, 1111•.. ( -- _1111... _ 1111.. ._ I. I _ 1 111 . .qrf .•..,, c..,_... .... ,., r,. - ... .•._..Mrs. v.. .. ! 1 111 ! .1.. . ....�... _ h 1, /' . •111 .•,. . «1111... _....__.....__ ... . .....J... L_ . �....,.,..__._.,......._ - 1 . .• .•.........._..,,..... 10'23!90 •!4: S6 STEUCiiS AE�ERDEEN RUPERT ENGINEERING, INC. 1501 W. Valley Highway N. Ste, 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833.7776 FAX f2d i 939.2168 oe SHEET NO.... NO.0 005 A /o — �$ CALCULATED BY _ A _ _ _ , DATE ./9/4 /1°0 CHECKED BY - DATE _ A 10/23/90 14136 STEUENS ABERDEEN • e . A- , ,,,,...eit.tt■ssf•.. ft.._ ,; ■ i ,, ... ...... _Pet+ . ' . ..•. I S 71 f .............A*. 04 ,,,' I.......r. . ........,.. .,.. L,...,f,,..( 1.i_ ........r,....--I...c.p...A3 ..,“ /4* f " • .. ..." • ' RUPERT ENGINEERING. 1501 W. Valley Highway N. Ste, 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833.7776 FAX (206) 939.2168 JOE cio4e) - .6 ..1Z••■•••■••■•■••■••••••■•■ SHEET NO. CALCULATED CHECKED BY NO. 023 006 .444 •■• • '3 1 , , ; ' I is' _ 1 .......!.... 7 iy. 1 ...' i ., ,. I l i war ' 1 I (4./ 1 ; I ....•.". 4 b ......,.. . ij 1 ..“ ... I , ■••••0 ..... 11•4 i. t ........ •••• i i 1 ...f, . .7... .1.14--... no *DM.. 1 1 1 •••■■••••• t or.■ ^••• .."41. .11. 1.1.0. ..1. ... ••• .... ./.1.00 •■,... L.... - • .... ... .... --- • ...Zvi.. .........Vio... Wars••■••••t••■•••••• I .0.1d1P0..114.44. i ••......t••■• as ■ Ow 711 1 i 1 i I —...;........ _.7. ' ir , 1 ..,, V . It 111 f t ...wino. 0101.... ...saw .........1 ___. ....._ itj ,....... ..a...... ...,.... 4........ V ................ ........3A._)e_..,.4...Y.t...._ ...... ....rel.. frorre.........MMO ...oast. nom... I 2 ...wow ..............•••molo ........ ....... • y . .9. . ........ ...ow ___. 1 • . •,.,... , ,.......".. ...... a............. .... ..... .• Iowa.... ............ -. _. , • .. ........" ....m.o. ......... .._.... .. . , ..,.. 4....000l • I •r ........ww.l.......... ..........., ......... ow.I.0 I ........_ _..._. .... . • 0 . .. elm.... I . II • . , 1............ ii . .__..1,..-......: ... . • 4 ..... I PrIMoro .., ....... l`t V. .. •••• ... I......... ....on. • PIll. 0 I. NlCilt ..., ........... .4........ .... .... r •RIMIONll ...a. 0 M..... —......r• .....=01141j..... r ] - i ',low l 1 ! . i i .., ••••• ow.. rm.... ._..... i low......0 earlrlo r■••••■•,. ---" ........,_..- .......... rm.. ---- ow e ..... ..... ..... I !......_i..... I !.../1;) ( • i I r I 1 ..,.. 4 ,,.......4........_._..., i Ar....... 4 ' 1- .. r .f.' . 1 • . • 1 cb ; - ; I ir 1.;..r0 r.............._...42 ......._ . 1 i , , 1 • 'it; 1) 1 t 1 1 t . 23? ..i ... mor...... 6 1 i be , ' . - 1 11.41awro• .40 ......■• ,..... ....... , A 10/23/90 14136 STEUENS ABERDEEN • e . A- , ,,,,...eit.tt■ssf•.. ft.._ ,; ■ i ,, ... ...... _Pet+ . ' . ..•. I S 71 f .............A*. 04 ,,,' I.......r. . ........,.. .,.. L,...,f,,..( 1.i_ ........r,....--I...c.p...A3 ..,“ /4* f " • .. ..." • ' RUPERT ENGINEERING. 1501 W. Valley Highway N. Ste, 101 P.O. Box 836 AUBURN, WASHINGTON 98071 (206) 833.7776 FAX (206) 939.2168 JOE cio4e) - .6 ..1Z••■•••■••■•■••■••••••■•■ SHEET NO. CALCULATED CHECKED BY NO. 023 006 .444 •■• • '3 f •,.. . ....r. . ....Ws. . r..• : � . E —: TE t I - .......... . : . • • .. r..... . .�....._....,_� * M . - ......r...E: . .•.••r. r .. , * II1 � , ,.. - - _.avow. Aro,* I... ei :ET , ..w.w. r ±:::: , . ...1 _ _.... » ». ...,....._..�. i ......... . '--t . .— ...r.r..+r � sw / �. . .wN... �, ' i f -L L � Y � 1 10/23/90' 14:3T 1801 W. Valley Highway N. Ste. 101 P.O. Sox 836 AUBURN. WASHINGTON 98071 FAX (206) 833.7776 RUPERT ENGINEERING, INC. • STEURgfs AOEM ER No. O 3 Jo. GHEiTNO. .._..— nr OF ..� CALCULATIO IV CHECKED SY. _ pATi OATS type of Inspectio T 2 <2 ! ' Date Wanted /c ,3- Site Address (i " . a.zc_a- ,e_e,� a_o Project ■_Tl equestor ih... k Phone # Special Instructions ILA-0(S Inspection Results /Comments: Inspector . LYMhwNO. NJaw Stl 7.•Y. ana+•l nlWYur.Y M, ww rn. .....r...........r..............» 6•••••1TiNM'a.N,+ “••• ••man•o••*+••••u. •wr w[ W. 1wRS/ MW.Y Mw••••.•+ wsiKa.w rw•... aHw ..nrn.a«r.". CITY OF TUKWILA Building Der ";ment 6300 SouthcA,,, ar Boulevard Tukwila, WA 98188 (206) 431 -3670 INSPECTI .N RECORD PERMIT # (,( 5 Date /, l/ — () Date ! 2.--t Z -TD • 111 • CITY OF TUKWILA Building D( .tment 6300 South er Boulev Tukwila, WA 98188 (206) 431 -3670 Type of Inspection Site Address Requestor Special Instructions Inspection Results /Comments: l/ Inspector INSPECTI N RECORD PERMIT # Date Date /2 -�G�r`�1 f 7-- mil' Date Wanted l2.---fe9 --q,U Project I ;..1 2 .._S' rai�� Ca Phone # ' �/ C, G p.m. 1908 FINALAPP.FRM City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Project Name Address / Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature ' shift inspection • l 4 • • TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Approved without correction notice Approved with correction notice issued Gary L. VanDusen, Mayor Control No. Permit No. 6s'" Suite # / 2 . •" Date T.F.D. Form F.P. 85 CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #90 -474: JPS Carpet Corp. 18437 Cascade Av S PHONE M (206) 433.1800 THE FOLLOWING COMMENTS APPLY TO AND BECOME PART F THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 3. When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner: Reports shall contain address, project name and permit number of the project being inspected. 4. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 5. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition). 6. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Gary L. VanDusen, Mayor "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431-3670 7 Framing 431 -3670 8 Insulation 431 -3670 y 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 11 12 13 x 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBUC WORKS FINAL 431 -3670 x 17 BUILDING FINAL 431 -3670 (INSPECTOR COMMENT SECTION ON REVERSE) SITE ADDRESS: CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDI!G PERMIT INSPECTION RECORD (Post with Building Permit in conspicuous place) SUITE NO.: BUILDING PERMIT NO. DATE ISSUED: PROJECT: 18437 Cascade Av S JPS Carpet Corp. CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (p INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are In place. 3. SLAB - If structural slab or if underslab insulation Is required. 4. SHEAR WALL NAILING - Prior to cover. 5. ROOF SHEATHING NAIUNG - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be Installed to keep attic ventlatbn points dear. 9. SUSPENDED CEILING - Fasten diffusers, Tights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) -- King County Health Department — 296-4732 Electrical — Washington State Department of Labor and Industries -- 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at `431 -3670. Although not required, a meeting of this typ^ ^an often eliminate problems, delays and misunderstandings as the project progresses. 011„4 "X" REQUIRED INSPECTIONS 1 Footings 2 Foundation 3 Slab and/or Slab Insulation 4 Shear Wall Nailing 5 Roof Sheathing Nailing 6 Masonry Chimney 7 Framing 8 Insulation 9 Suspended Ceiling 10 Wall Board Fastening 11 12 13 X 14 FIRE FINAL Insp: 15 PLANNING FINAL 16 PUBLIC WORKS FINAL X17 BUILDING FINAL PLAN CHECK NUMBER 90.- 471- °r'ROJECT: ,IFS, CA4 •=-T C THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER . R No changes will be made to the plans unless approved by the - Archi- 444-t• and the Tukwila Building Division. t ....14C l AMC:R- Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4732). Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872- 6363). O All mechanical work shall be under separate permit through the City of Tukwila. 29 All permits, inspection records, and approved plans shall be I/�� posted at the Job site prior to the start of any construction. da When special inspection is required either the owner, architect or ttt����/// engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. O All structural concrete to be special inspected (Sec. 306, UGC). da All structural welding to be done by W.A.B.0. certified welder and special inspected (Sec. 306, UGC). O All high - strength bolting to be special inspected (Sec. 306, UGC). 10 Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic lone 3. 11 Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. O Readily accessible access to roof mounted equipment is required. 13 Engineereed truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14 Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. l3 Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure.). 16 A statement from the roofing contractor verifying fire retardancy of roof Will be required prior to final inspection (see attached procedure). lS 1 T7 All construction to be done in conformance with approved plans and 1/ requirements of the Uniform Building Code (1998 Edition), Uniform Mechanical Code (1988 Edition), Washignton State Energy Code (1989 Edition), and Washington Stag Regulations for Barrier Free Facility (1989 Edition). 18 All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296-4787, at least three working days prior to desire inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the Job site. Firs retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20 Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21 All spray applied fireproofing as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22 All wood to remain in placed concrete shall be treated wood. O All structural masonry shill be special inspected per U.B.C. Section 306 (a) 7. 0 Validity of Permit. The issuance of a persit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No pgrsit presuming to give authority or violate or cancel the provisions of this code shall be valid. Dear Sir: CitIrof Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Fire Department Review Control Number 90 -474 (512) Re: J.P.S. Carpet Corporation - 18437 Cascade Avenue South Gary L. VanDusen, Mayor November 29, 1990 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFC 12.107(a)(b)) 2. All modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, Page number 2 Yours truly, it of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 sue, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd Gary L. VanDusen, Mayor then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) (NFPA 13, 1 -9.1) (UFC 10.307) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1 -10.2) (UFC 10.305(b)) 3. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. STEVENSCARPET JPS Carpet Corp 6841,'South 190th Sr: Kent, WA 98032 November, 9;1990 City of Tukwila Department of Community Building Division 6300 Southcenter Blvd. Tukwila, WA 98188 Dear Sirs, Move fire hose out to end of the rack. We need to_ have your fire, inspectors determine •requirements for the access to the fire hose on highlighted post. Development RECEIVED CITY OF TUKWIIA NOV 1 51990 PERMIT CENTER S'ncerely, im McKay r Regional Manager Stevens Carpet the . NOV 13 1990 CITY (*.) I uKirvi ,A PLAAIh�INC DEPT Our understanding of options are: Leave 3' path front' and back'. CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 November 14, 1990 Mr. James McKay 6841 South 190th Street Kent, WA 98032 Dear Mr. McKay: On November 13, 1990 we received the enclosed application for a rack storage permit. It is our policy not to accept applications by mail. I am returning this application to you so that you may complete the following information: 1. Assessor Account Number. A 7 0 569 - 0,09e 2. Square footage - building, tenant space, and area of construction. gg////Q /5000 Gv %.e ..v�l 3. Expiration date on contractors license number. 4. Two sets of plans (rack storage layout). I have also enclosed a memo showing the rack storage fees calculated out. I would appreciate it if you would complete the application and return the application to our office during our regular office hours 8 :30 a.m. to 5:00 p.m. If you have any questions, please feel free to call me at 431 - 3671. Sincerely, .125ZYNakk:33fotra Shellie Bates Permit Technician Enclosures PHONE q (206) 933.1800 /90 Gary l.. VanDasen, Mayor