HomeMy WebLinkAboutSpecial 2014-04-03 Southcenter Plan - C. Draft Southcenter Design ManualCity of Tukwila Draft Southcenter Design Manual CITY COUNCIL REVIEW DRAFT Planning Commission Recommended Draft with Staff Updates 03/25/2014 145 Draft Southcenter Design Manual Table of Contents Introduction i Site Design Elements 1. Site Design 1 2. Service areas and mechanical equipment 3 3. Lighting 6 4. Walls and Fences 7 5. Open Spaces 10 Building Design 6. Architectural Concept 12 7. Entrances and Doors 13 8. Building facade — Base and Top 17 9. Corner Treatments 23 10. Building massing 24 11. Building details and elements 32 12. Building Materials and Colors 35 13. Windows 40 14. Weather protection 43 15. Blank Walls 46 16. Parking Structures 48 1 4&iCDesignManual _PCDraft_Updated.docx 03/02/14 47 Draft Southcenter Design Manual INTRODUCTION Purpose The Southcenter Design Manual provides policy guidance on site and building design. The guidelines support and complement the community vision described in the Southcenter Subarea Plan, and provide a flexible tool for quality and innovation. This document is intended to supplement and expand upon the design requirements found in Chapter 18.28 Tukwila Urban Center (TUC) Zoning standards. This document provides City staff, the Board of Architectural Review (BAR), and the public a common basis for the evaluation of design and development issues during the design review and approval process. The Manual does not specify a particular style of architecture or design but is intended to guide applicants in creating an appearance of greater consistency and design quality within the Southcenter District. Organization The Southcenter Design Manual is organized by design topic. The general structure is: 1. DESIGN TOPIC (E.G. WINDOWS) Intent Statement • Provided to guide the application of criteria to differing site circumstances in a consistent manner. Design Criteria A. Design Criteria: General requirements to be met by development 1. Example measures that guide development design to meet the design topic intent and design criteria above. Graphic and written descriptions are provided. For each Design Topic there are one or more Design Criteria, which can be general in nature. The Design Criteria explain the requirements for development proposals. They are the decision criteria by which the Director or Board of Architectural Review will decide whether to approve, condition or deny a project. The examples and explanations beneath, which augment each Design Criteria, provide guidance to the project applicant developing the project, to City staff in reviewing a project proposal, and the decision maker in determining whether the project meets the Design Criteria. These are intended to provide guidance and possible solutions for the criteria but should not be seen as the only solution. There may be specific requirements to include or avoid. Photographs and illustrations appear beneath the item they are intended to explain. Interpretation Where the word "shall" or "must" is used it is intended to be a mandate; and where the word "should" or "encouraged" is used, it is intended to be a recommendation. In determining the degree of applicability of design criteria or in case of conflict or site impracticality, priority should be given to criteria related to the "public realm." Not all criteria will be applicable to every project. 148CDesignManual _PCDraft_Updated_CLEAN.docx i 03/25/2014 Draft Southcenter Design Manual This Manual describes, in clear terms, those features that are to be addressed in the design of projects. It is evident that the criteria could generate numerous solutions. Varied and imaginative designs are certainly encouraged. Photographs are often included as visual examples for design and review purposes. They are not intended to be specific examples to be replicated. Where an addition to or expansion of an existing building triggers design review the new construction shall meet all relevant criteria. In addition limited exterior modifications to the existing structure may be required to aesthetically unify the new and existing portions of the structure and better meet the design criteria. SCDesignManual _PCDraft_Updated_CLEAN.docx ii 03/25/2(149 Draft Southcenter Design Manual SITE DESIGN /ELEMENTS 1. SITE DESIGN Intent • To encourage site design in which the organization is easily understood, appropriate to the area, takes advantage of unique opportunities, and is a positive element in the architectural character of the District within which it is located. Design Criteria A. Design sites to take advantage of special opportunities and mitigate impacts while demonstrating a unifying organization that accomplishes the following goals: 1. Facilitate better traffic circulation by connecting through streets, where applicable. 2. Provide a safe, convenient, and connected pedestrian access system. For example, redevelopment of a superblock site should strive to create a pedestrian - friendly environment within the internal layout. In addition to providing any required new streets, this can be accomplished by defining a network of pedestrian walkways that serve as a "grid ", connecting these walkways to uses with the site and to the larger street network, and creating smaller parking areas in place of one large parking lot. 3. Encourage buildings to complement adjacent activities and visual character (where desirable). 4. Arrange buildings to enhance the site's street frontages and the overall pedestrian environment. For example, on sites where large retail stores are planned, small retail shops may be clustered along the street with parking behind that serves both the small and large retail uses. 5. Incorporate open space and landscaping as a unifying feature. 6. Incorporate screening, environmental mitigation, utilities, and drainage as positive design elements. 7. Incorporate opportunities for joint development of sites where there is potential for common building walls, shared driveways, landscaping, or other shared facilities. 8. Use site design to take advantage of and /or enhance views of or access to the river, pond, surrounding hillsides, and mountains, where feasible. 1 50c DesignManual _PCDraft_Updated_CLEAN.docx 1 03/25/2014 Draft Southcenter Design Manual Good internal circulation and connections to adjacent sites- Parking lot landscaping and buffering Pedestrian-oriented street frontages Centralized pedestrian space Use Site Design to break up super blocks. SCDesignManual _PCDraft_Updated_CLEAN.docx 2 03/25/2Qi1 Draft Southcenter Design Manual 2. SERVICE AREAS AND MECHANICAL EQUIPMENT Intent • Minimize the potential negative impacts of service elements through thoughtful siting and screening while meeting functional needs Design Criteria A. Service element location and design. Provide designated areas for service elements (refuse and disposal) that meet the following standards: 1. Locate service elements to minimize the negative visual, noise, odor, and physical impacts to the street environment, adjacent (on and off -site) residents or other uses, and pedestrian areas. All service entrances and associated loading docks and storage areas should be located to the side or rear of the building unless all facades face a public street in which case locate them in the least visible location or screen them with landscaping. If possible integrate service enclosures into the building itself; 2. Minimizing impacts to adjacent residential units is the highest priority in determining appropriate service element location and treatment, followed by impacts to office and retail uses; 3. Pave the designated spot for service elements with concrete for durability and ease of maintenance; SCREENED LOCATED AT MECHANICAL EQHIPMICA 0UMPSfER REAR OF ,- SITE ' I tip NOA I -ASH O• 4,0#>0 40"/ / Appropriate service area location and enclosure example. 4. Enclose and screen service areas visible from any street, pathway, pedestrian- oriented space or public parking area (alleys are exempt) with a durable wall or fence at least 6 feet high. Use materials and detailing consistent with primary structures on -site. Acceptable materials include brick, concrete block or stone; 5. Locate and configure collection points so that the enclosure gate swing does not obstruct pedestrian or vehicle traffic, or does not require that a hauling truck project into any public right - of -way; 6. When service elements are visible from the street, dwelling units, customer parking areas, or pathways, soften the appearance of the sides and rear of the enclosure with landscaping 5 2DesignManual _PCDraft_Updated_CLEAN.docx 3 03/25/2014 Draft Southcenter Design Manual B. Automotive Service Bays: Buildings containing automotive service bays shall be designed to minimize their visibility from the public realm. 1. Either orient the service bay doors in the direction least visible from the public realm or screen the doors with walls, trellises or landscaping. 2. Framing elements such as trellises and trim around the edges of service bay doors are recommended to add depth and detail to the automobile scaled facade. C. Utility meters, electrical conduit, and other service utility apparatus. 1. Locate and /or design these elements to minimize their visibility to the public. Project designers are strongly encouraged to coordinate with applicable service providers early in the design process to determine the functional requirements for the equipment and the best approach to meeting these standards. 2. If such elements must be mounted in a location visible from a street, pedestrian pathway, common open space, or shared auto courtyard screen them with vegetation or architectural features. Good and bad utility meter configurations. The examples on the left are consolidated and somewhat screened by landscaping elements, whereas the right examples are exposed and degrade the character of these townhomes. D. Rooftop equipment screening. Screen all rooftop mechanical equipment so that it is not visible from public streets and sidewalks within 300 feet of the subject property, except from points of view in excess of 10 feet above finished site grade of the subject property. 1. The first preference is to either place the equipment where it is not visible due to roof forms or parapet walls. 2. If equipment must be placed where it is visible screen it with elements that are architecturally compatible with the building design. 3. Design the screening using materials, architectural styles, colors and /or other elements from the facade to integrate the screening into the building's architecture. SCDesignManual _PCDraft_Updated_CLEAN.docx 4 03/25/21153 Draft Southcenter Design Manual 4. In the design of screening enclosures, use dimensional increments of window spacing, mullion spacing, or structural bay spacing taken from the facade composition. E. Downspouts. 1. Where possible, downspouts should be concealed within walls while meeting the requirements of plumbing codes and providing for maintenance. 2. The location, spacing, materials, and colors of exposed downspouts, gutters, scuppers, and other visible roof drainage components should be incorporated into the architectural composition of the fagade and roof; haphazard placement should be avoided. Half round gutters and round downspouts are recommended as a type appropriate for most architectural styles. Corrugated downspouts should not be used. Screening example of rooftop mechanical equipment. 1 S lCDesignManual _PCDraft_Updated_CLEAN.docx 5 03/25/2014 Draft Southcenter Design Manual 3. LIGHTING Intent • To design site lighting that accents the architecture, improves safety and avoids impacts to adjacent properties and passersby. Design Criteria A. Design site lighting to promote safety as well as enhance the nighttime appearance of buildings and landscaping. 1. Commercial buildings and landscaping can be illuminated indirectly by concealing light features within buildings and landscaping to highlight attractive features and avoid light intrusion into neighboring properties. i�i,. 7 11"v: mil; 1, art 2. Bollard mounted lighting and stair lighting are recommended for low -level illumination of walkways and landscaped areas. 3. Illuminate public entrances at night to enhance safety and visibility. B. Avoid glare from unshielded or undiffused light sources. 1. Small decorative "glow" elements within a luminaire such as bollard mounted lighting or stair lighting are permitted to emit a low amount of light above the horizontal. 2. Prevent spillover light and glare from being visible to pedestrians, motorists, and nearby residential dwelling windows through shielding and careful placement. Glare can create a major safety hazard for motorists. 3. Illumination levels of fagade uplighting, roof wash lighting and landscape uplighting should use lower brightness levels where the illuminated fagades, roofs or landscaping face residential buildings, except across wider streets or boulevards with landscaped medians and street trees. SCDesignManual _PCDraft_Updated_CLEAN.docx 6 03/25/21155 Draft Southcenter Design Manual 4. WALLS AND FENCES Intent • To design walls and fences that are compatible with the building, improve the appearance of the site and improve safety. Design Criteria A. Design walls and fences to create a sense of entry and enhance the street frontage. 1. Frontage walls may occur as garden walls, planter walls, seat walls, or low retaining walls. Seating walls should be between 15 " -18" in height and a minimum of 18" wide to provide comfortable seating. 2. Entrances and pedestrian "gateways" should be announced by posts or pilasters, and may be combined with trellises, special landscaping, decorative lighting, public art or other special features. Low walls as a transitional, decorative element to soften the wall. Low walls with landscaping to separate public space from semi - private space. 5eDesignManual _PCDraft_Updated_CLEAN.docx 7 03/25/2014 Draft Southcenter Design Manual Decorative masonry and stone walls to define space. B. Design walls and fences to screen unsightly portions of the site and enhance security. 1. Screening fences and walls should be constructed of materials that are compatible with the architecture and character of the site. Natural colors, a cap or top articulation, and related dimensional post spacing increments should be used at screening fences to enhance compatibility. 2. All walls should have a cap and base treatment. 3. Design elements should be used to break up long expanses of uninterrupted screening walls, both horizontally and vertically. Walls should include design elements such as textured concrete block, interlocking "diamond" blocks, formed concrete with reveals, or similar materials. Landscape materials should also be used to provide surface relief. 4. Use of security fences should be minimized, and limited to special locations where additional security is necessary. Such security fences should not exceed 6 feet in height. 5. Security fences should be designed to maintain a visually open character to the extent possible. This may be accomplished by using metal picket or open grille fencing or by mounting metal picket or open grille fencing on top of a low masonry wall. 6. Seek Fire Department review and approval for all bollards protecting Fire Department equipment. SCDesignManual _PCDraft_Updated_CLEAN.docx 8 03/25/21157 Draft Southcenter Design Manual Good screening wall examples. Landscaped trellis wall as a visual screen (left). The trash enclosure (right) uses a decorative pattern of concrete blocks and metal doors that complement the architecture of the adjacent building. 1 58CDesignManual _PCDraft_Updated_CLEAN.docx 9 03/25/2014 Draft Southcenter Design Manual 5. OPEN SPACE Intent • Provide safe, attractive, and usable open spaces that promote pedestrian activity. • Create open space that enhances the setting and character of residential, commercial, and mixed -use development. Design Criteria A. Pedestrian Space Design Guidelines (for commercial uses). 1. Provide a variety of seating options, including benches, seating steps, planters, landscaping features, or low walls. When designing seat walls with straight edges of more than six feet in length, add detailing that will prevent damage from skateboards. 2. Provide areas of sun and shade for year -round climatic comfort, and, where desired, shelter and night lighting to encourage public activity and ensure safety. 3. Include specimen trees and seasonal plantings. 4. Landscaping should not act as a visual or physical barrier to adjacent sidewalks. 5. Include artwork, water features, trellises or shelters, and decorative paving in pedestrian spaces. 6. Public gathering places should be equipped with 115- and 220- volt outlets as appropriate for entertainment or commercial use. 7. Detail public gathering places and other publicly accessible areas with decorative, pedestrian - scaled site furnishings and equipment such as seating, freestanding planters, ornamental solid waste and recycling receptacles, bike racks, drinking fountains, pergolas, trellises, heaters, umbrellas, wind screening, and decorative bollards. 8. Components of site furnishings should be made of durable high quality materials such as painted fabricated steel, painted cast iron, painted cast aluminum, and integrally colored precast concrete. Recycled materials should be used so long as the finish or look of the material is consistent with or similar to the finishes prescribed above. Metal surfaces should be coated with highly durable finishes such as aliphatic polyurethane enamel. 9. Landscape structures and sculptural objects in pedestrian spaces should reference the human scale in their overall massing and detailing. B. Private open space for residential units. 1. Create privacy between units with balconies either structurally or having at least 10 feet horizontal space between balconies. SCDesignManual _PCDraft_Updated_CLEAN.docx 10 03/25/2C1159 Draft Southcenter Design Manual C. Common open space for residential units. 1. Provide individual entries onto common open space from adjacent ground floor residential units. Small, semi - private open spaces for adjacent ground floor units that maintain visual access to the common area are encouraged to enliven the space. Use low walls or hedges (less than 3 feet in height) to provide clear definition of semi - private and common spaces. Common open space examples that integrate semi - private spaces with direct unit access to the common open space. 1 602DesignManual_PCDraft_U pdated_CLEAN.docx 11 03/25/2014 Draft Southcenter Design Manual BUILDING DESIGN 6. ARCHITECTURAL CONCEPT Intent • To encourage building design in which the organization is easily understood, appropriate to the site, and is a positive element in the architectural character of the District within which it is located. Design Criteria A. Develop an architectural design expression that unifies the massing and components of a structure or structures on a site into a cohesive and consistent thematic or stylistic architectural character or style that is responsive to the functional requirements of the development. 1. Example of axial symmetry, or more formal design organization, in a multi - family building. 2. Example of asymmetry, or more informal composition, in a commercial building. SCDesignManual _PCDraft_Updated_CLEAN.docx 12 03/25/2Q1 Draft Southcenter Design Manual 7. ENTRANCES AND DOORS Intent • Ensure a welcoming public face to buildings with well designed, appropriately scaled, and easy to find entrances. • Entrances should be visually prominent features in the design of a building. • Design retail and commercial entries to create an open atmosphere that draws customers inside, and residential entries that are welcoming and provide a graceful transition between the public and private realm. Design Criteria A. Primary entrances are among the most visible and characteristic features of a building. Locate and design the main entrance door(s) and the surrounding frame to represent the overall style and architectural character of the building. 1. The primary entrance may be: a) marked by a taller mass above, such as a modest tower or portico (roofed entrance supported by columns) that protrudes from the rest of building surface; b) accented by special architectural elements, such as columns, overhanging roofs, a permanent architectural canopy utilizing materials from the primary building, projecting canvas or fabric awnings, and ornamental light fixtures; Examples of permanent architectural canopies 162CDesignManual _PCDraft_Updated_CLEAN.docx 13 03/25/2014 Draft Southcenter Design Manual c) indicated by a recessed entry opening onto the public sidewalk or a forecourt. This design could be incorporated into commercial, residential, or mixed -use buildings. Recommended treatments include special paving materials such as ceramic tile; ornamental ceiling treatments (for recessed entries), such as coffering; decorative light fixtures; and decorative door pulls, escutcheons, hinges, and other hardware. K Of SIDEWALK ■■■ II ■ ■I ■ ■N■■■ MIENS �� ■ii ■MMEN • A recessed entry could be fully enclosed from above or could come in the form of a forecourt (right image) 2. Residential developments may use the following entry treatments: a) Stoop. A stoop is an entrance stairway to a residence typically constructed close to the sidewalk. Stoops may feature a portico entrance at the top of the stair. Multiple stoops may be combined to increase the scale of the entrance. Setback areas are typically landscaped. Stoops SCDesignManual _PCDraft_Updated_CLEAN.docx 14 03/25/21 )33 Draft Southcenter Design Manual Stoop examples. b) Porch. A porch is a roofed space, open along two or more sides and adjunct to a building, commonly serving to shelter an entrance and provide a private outdoor space appended to a residence. Porches may serve multiple entrances. Setback areas are typically landscaped. Porch O CM'AAR c) Front door. A front door features a residence's main entrance with a deep setback, creating a gracious open space along the property frontage. Setback areas are typically landscaped. Special paving should be used to enhance and define the entrance. 3. Ground floor multi - family residential units should have dedicated entrances wherever possible. 64CDesignManual _PCDraft_Updated_CLEAN.docx 15 03/25/2014 Draft Southcenter Design Manual B. At mixed -use buildings, clearly distinguish entrances to residential, office or other upper story uses from retail entrances. 1. Residential entries distinguishable from commercial entries. Use different materials, building forms, door styles, and /or building perforations in retail /commercial spaces than residential entrances. 2. Accent the entrance with architectural elements such as clerestory windows, sidelights, and ornamental light fixtures, and identify it with signage and /or address numbering. 3. The entrance may be recessed into a vestibule or lobby distinguishable from storefronts. C. Secondary Entrances: Design side or rear building entries to be consistent with but visually secondary to main entrances. Side or rear entries (left) shall be consistent, but secondary to the primary entrance (right). 1. Use materials and proportions to architecturally relate the side or rear entry to the design of the front entry. 2. Secondary entries should be enhanced with detailing, trim and finish consistent with the character of the building. 3. Large multi- tenant buildings may have multiple main entrances. SCDesignManual _PCDraft_Updated_CLEAN.docx 16 03/25/2C1135 Draft Southcenter Design Manual 8. BUILDING FACADE - BASE AND TOP Intent • To ensure that individual elements of a facade relate to the fagade's overall design, articulation, and organization. • To reduce the scale of large buildings. • Encourage prominent rooflines that give buildings an attractive and distinctive top, contribute to the character of the area, and are consistent with the type of building function and uses. • Encourage the use of sloped roofs for residential buildings to shed rain and snow and provide shelter. Design Criteria A. Create a building base where the horizontal articulation of the lower part of a building facade's design establishes a human scale for pedestrian users and passers -by, and aesthetically "ties" a building to the ground. 1. Provide a building base treatment at both of the following scales on commercial buildings: a) At the scale of the pedestrian (i.e. within the ground floor portion of the facade), a base treatment should be created at a height between nine inches and six feet. Examples of pedestrian - scaled building base treatments. Note the tilework below the storefront window in the left image, concrete base in the middle and right images. b) For multi -story buildings, at the scale of the building the facade of the entire ground floor (or up to the second floor, depending on the height of the building) should be designed to read as a base that "anchors" the building (i.e., the portion of the fagade above) to the ground. 1 66CDesignManual _PCDraft_Updated_CLEAN.docx 17 03/25/2014 Draft Southcenter Design Manual Base treatment examples for multi -story buildings. 2. Create the building base by any one or more of the following treatments: a) A horizontal projection (or visible thickening) of the wall surface, which may be accompanied by a change of material and /or color; this may be an exterior version of a "wainscot." b) A material and /or color change of the base wall relative to the building wall above. The base material should be heavier (e.g. of darker color and /or a heavier or more permanent material) than portions of the building above. Examples of color and material changes to differentiate base of building c) A horizontal architectural line or feature at or below the top of the first story, such as a belt course, protruding horizontal band or secondary cornice (related to or repeating the pattern of an upper cornice) separating the first two floors. d) At non - residential buildings a ground level arcade with columns may be used to create a building base. Column spacing should be regular, and related to the structural bay increment of the building. B. Create a "top" on buildings through a substantial horizontal articulation of the facade at the uppermost floor of the building to provide an attractive facade skyline and complete the upper facade composition. 1. Architecturally integrate this "cap" with any sloping roof volume (if used) that occurs above the eave line. 2. Rooflines should reflect the architectural style of the building and be a distinctive design element. SCDesignManual _PCDraft_Updated_CLEAN.docx 18 03/25/2037 Draft Southcenter Design Manual Examples of distinctive rooflines 3. Pitched and continuous sloping roof forms (i.e. without flat horizontal portions) including gable, hip, and pyramidal roofs are encouraged. Examples of pitched rooflines 4. Roof surfaces should be punctuated with varying roof forms to break up large massing of roof surfaces and /or to provide opportunities to daylight interior spaces. Examples of varying roof forms 1 68CDesignManual _PCDraft_Updated_CLEAN.docx 19 03/25/2014 Draft Southcenter Design Manual 5. Ornament flat or shallow pitched roofs with shaped parapets, caps, or cornice treatments. a) The primary cornice should be decorated or bracketed with parapets, finials, or simple decorative panels or molding. b) An architecturally profiled cornice and /or expressed parapet cap should be used to terminate the top of the parapet wall. c) Surface mounted cornices, continuous shading elements, or trellises should be used to strengthen a parapet wall design. d) Sheet metal parapet caps or coping should provide a formed (compound folded) overhanging edge termination and a heavy gage sheet metal thickness selected to avoid "oilcanning" distortion. Single layer, flush sheet metal parapet caps should not be used. Finish should either be of an unpainted ornamental metal such as copper, or painted to match adjacent wall surface. Unpainted galvanized metal should not be used. 6. Roof overhangs for both flat and sloping roofs are encouraged to add depth, shadow and visual interest. a) Vertical roof edge fascia over eighteen inches in height should be subdivided or accented by additional horizontal layers, stepbacks, trim, and other detailing. SCDesignManual _PCDraft_Updated_CLEAN.docx 20 03/25/2039 Draft Southcenter Design Manual b) Brackets and corbels (i.e. decorative supporting pieces designed to bear the weight of projected overhangs), or other expressed roof overhang supports (whether structural or nonstructural) are encouraged to add richness to detailing. The spacing module of repeating supports should relate to the building's structural bay spacing or window mullion spacing. c) The soffit (i.e. the underside surface of the roof overhang) should be designed as a visible feature and incorporated into the overall architectural composition. Soffit beams, coffers, light fixtures and other design articulation are encouraged. Top or "cap" examples — dramatic roof forms. 1702DesignManual _PCDraft_Updated_CLEAN.docx 21 03/25/2014 Draft Southcenter Design Manual Top or "cap" examples — various cornice lines. Top or "cap" examples: Vertical modulation plus combined with changes in materials and detailing (left). Distinctive sloped roof form (right). Top or "cap" examples — horizontal modulation (upper level stepbacks). SCDesignManual _PCDraft_Updated_CLEAN.docx 22 03/25/2Q171 Draft Southcenter Design Manual 9. CORNER TREATMENTS Intent • To emphasize the importance of intersections through special design elements. Design Criteria A. Emphasize building corners at important intersections with a distinctive building element. 1. Appropriate building elements include: a) Corner towers which are created by articulating a separate, relatively slender mass of the building, continuing that mass beyond the height of the primary building mass, and providing the top of the mass with a recognizable silhouette, b) Projecting or recessed corner entrances with a distinctive roof or canopy element, c) Distinctively shaped bay windows or balconies. 172CDesignManuaI _PCDraft_Updated_CLEAN.docx 23 03/25/2014 Draft Southcenter Design Manual 10. BUILDING MASSING Intent • To ensure, through horizontal and vertical modulation, that the apparent height and length of a building maintains the desired human scale and character for the Southcenter area. • To reduce the scale of large buildings • To encourage the design of building facades which incorporate interesting architectural details that add variety to the facade, animate the street presence, and are attractive at a pedestrian scale. Design Criteria A. Facade articulation — commercial and mixed -use building facades. Employ at least three of the following features at intervals no greater than specified by the applicable corridor type to reduce the perceived scale of buildings and add visual interest: 1. Window fenestration patterns and /or entries; 2. Use of weather protection features; 3. Use of vertical piers or columns; 4. Change in roofline form; 5. Change in building material or siding style 6. Vertical elements such as a trellis with plants, green wall, or art element; 7. Providing vertical building modulation of at least 12 inches in depth if tied to a change in roofline or a change in building material, siding style, or color; 8. Other design techniques that effectively reinforce the pattern of small shopfronts and /or effectively reduce the perceived scale of the building and add visual interest. 9. Alternative designs will be considered provided such techniques effectively reduce the perceived scale of the building and add visual interest from all observable distances. The City shall consider the following in determining whether the treatment meets the intent of the guidelines: a) Types of materials used and how they help to achieve the intent; b) The type of articulation treatments and how effective they are in meeting the intent; c) How effective the articulation treatments respond to the site's context and visibility (for instance, side streets warrant greater flexibility than primary streets where facades are more visible). SCDesignManual _PCDraft_Updated_CLEAN.docx 24 03/25/2Q173 Draft Southcenter Design Manual Articulation increment Articulation increment Articulation increment Nom I� fft CENTER WEsT • " PAM„ at , Entries and fenestration patterns mown lownweLn.mmini. I -- Vertical piers /columns Weather protection elements Facade articulation example 1 74CDesignManual _PCDraft_Updated_CLEAN.docx 25 03/25/2014 Draft Southcenter Design Manual For retail facades, one way of meeting the articulation provisions is to design individual storefronts or increments to look like separate buildings. Facades in these examples use different materials, colors, fenestration techniques, rooflines, and weather protection elements. Facade articulation examples for multi -story buildings. The ground level commercial facades employ entries and fenestration techniques, vertical piers, and weather protection elements. SCDesignManual _PCDraft_Updated_CLEAN.docx 26 03/25/211755 Draft Southcenter Design Manual Unacceptable facade articulation techniques. Both examples use some articulation features, but they are insufficient in meeting the intent of the guidelines. B. Facade articulation — multifamily building facades. This includes single purpose multifamily buildings and residential portions of mixed -use buildings. Employ at least three of the following features at intervals no greater than specified by the applicable corridor type to reduce the perceived scale of buildings and add visual interest: 1. Window fenestration patterns and /or entries; 2. Vertical building modulation. Minimum depth and width of modulation is 18 inches and four feet, respectively, if tied to a change in color or building material and /or roofline modulation. Otherwise, the minimum depth and width of modulation is 10 and 15 feet, respectively. Balconies may be used to meet the modulation if they are recessed or projected from the facade by at least 18 inches. Juliet balconies, and other balconies that appear to be "tacked -on" to the facade will not qualify for this option unless they employ high quality materials and add visual interest to the facade; 3. Change in roofline; 4. Change in building material or siding style; 5. Building elements such as bay windows, porches, canopies, chimneys, or other repetitive features that effectively articulate the facade; 6. Other design technique that effectively reduces the perceived scale of the building and adds visual interest. 7. Alternative designs will be considered provided such techniques effectively reduce the perceived scale of the building and add visual interest from all observable distances. The City shall consider the following in determining whether the treatment meets the intent of the guidelines: a) Types of materials used and how they help to achieve the intent; b) The type of articulation treatments and how effective they are in meeting the intent; 1 7eDesignManual _PCDraft_Updated_CLEAN.docx 27 03/25/2014 Draft Southcenter Design Manual c) How effective the articulation treatments respond to the site's context and visibility (for instance, side streets warrant greater flexibility than primary streets where facades are more visible). 111 11 11 11 111 11111111111 -- _J 1111111111111 Multifamily facade articulation example. Examples of multifamily facade articulation. C. Major Vertical Modulation Increment. Incorporate at least one of the following design elements at intervals no greater than specified by corridor type to reduce the perceived scale of buildings and add visual interest: 1. Provide major vertical building modulation at least 10 feet deep and 20 feet wide. Such modulation may be recessed from the wall or project from the wall. For multi -story buildings the modulation must extend through more than one -half of the building floors; 2. Use of a contrasting vertical modulated design component featuring all of the following: a) Component extends through all floors above the first floor fronting on the street. Exception: upper floors that are stepped back more than 10 feet from the facade are exempt; b) Utilizes a change in building materials that effectively contrast from the rest of the facade; SCDesignManual _PCDraft_Updated_CLEAN.docx 28 03/25/2Q177 30' max. i 30' max. 30' max. 111 11 11 11 111 11111111111 -- _J 1111111111111 Multifamily facade articulation example. Examples of multifamily facade articulation. C. Major Vertical Modulation Increment. Incorporate at least one of the following design elements at intervals no greater than specified by corridor type to reduce the perceived scale of buildings and add visual interest: 1. Provide major vertical building modulation at least 10 feet deep and 20 feet wide. Such modulation may be recessed from the wall or project from the wall. For multi -story buildings the modulation must extend through more than one -half of the building floors; 2. Use of a contrasting vertical modulated design component featuring all of the following: a) Component extends through all floors above the first floor fronting on the street. Exception: upper floors that are stepped back more than 10 feet from the facade are exempt; b) Utilizes a change in building materials that effectively contrast from the rest of the facade; SCDesignManual _PCDraft_Updated_CLEAN.docx 28 03/25/2Q177 Draft Southcenter Design Manual c) Component is modulated vertically from the rest of the facade by an average of 6 inches; and d) Component is designed to provide roofline modulation; or 3. Facade employs building walls with contrasting articulation that make it appear like two distinct buildings. To qualify for this option, these contrasting facades must employ both of the following: a) Different building materials and /or configuration of building materials; and b) Contrasting window design (sizes or configurations). 4. Alternative treatments will be considered provided the design meets the intent of the guidelines. Elements to consider are the level of detailing, quality of building materials, types of articulated features, and integration with /or enhancement of, the surrounding context (considering views from all publicly observable locations within the area). X = Maximum modulation increment is specified by corridor MEETS REQUIREMENT dot \ef'5 DOES NOT MEET REQUIREMENT Major vertical building modulation (at least 10' deep by 20' wide) MEETS REQUIREMENT Illustrating Major Vertical Modulation Increment standards. 1 78CDesignManual _PCDraft_Updated_CLEAN.docx 29 03/25/2014 Draft Southcenter Design Manual The above examples do not meet the modulation increment standard. In the left image, the modulated features aren't enough to mitigate the continuous massing of the upper level of the building. The right image includes small scale vertical modulation, but over an extensive width, it isn't sufficient enough to effectively reduce its perceived width. Acceptable examples. The left image meets the criteria for (2) above for a contrasting vertical modulated design component. The right image meets the criteria for (1) above for vertical building modulation at least 10 feet deep and 20 feet wide. Acceptable examples. Both large scale retail examples above use major vertical building modulation features (1) and most or all of the features of a vertical modulated design component (2). SCDesignManual _PCDraft_Updated_CLEAN.docx 30 03/25/21179 Draft Southcenter Design Manual Acceptable "alternative" examples. The left image includes five articulated facade intervals — with the central component using different materials, fenestration, and roofline modulation. The right image uses a combination of vertical and horizontal modulation and a change in building materials to meet the intent of the standards. 18 DesignManual _PCDraft_Updated_CLEAN.docx 31 03/25/2014 Draft Southcenter Design Manual 11. BUILDING DETAILS AND ELEMENTS Intent • To encourage the incorporation of design details and small -scale elements into building facades that are attractive at a pedestrian scale. Design Criteria A. Employ detail elements from each of the three categories below on facades facing a street, featuring a customer entry, or featuring the primary residential entry. For non - residential and mixed -use buildings include at least one detail from each category within each facade articulation increment (see TMC 18.28.200) and for residential buildings include at least two detail features from each category within each articulation increment. For example, a residential building with 120 feet of street frontage with a facade articulated at 30 -foot intervals will need to include two of the detail elements from the three categories below within each of its four facade segments. 1. Window and /or entry treatment: a) Display windows divided into a grid of multiple panes; b) Transom windows; c) Roll -up windows /doors; d) Other distinctive window treatment that meets the intent of the standards; e) Recessed entry; f) Decorative door; g) Landscaped trellises or other decorative element that incorporates landscaping near the building entry; or h) Other decorative or specially designed entry treatment that meets the purpose of the standards. 2. Building elements and facade details: a) Custom - designed weather protection element such as a steel canopy, cloth awning, or retractable awning; b) Decorative, custom hanging sign(s); c) Decorative building- mounted light fixtures; d) Bay windows, trellises, towers, and similar elements; or e) Other details or elements that meet the intent of these standards. 3. Building materials and other facade elements: a) Use of decorative, high quality building materials. Examples include decorative use of brick, tile, or stonework; SCDesignManual _PCDraft_Updated_CLEAN.docx 32 03/25/2181 Draft Southcenter Design Manual b) Artwork on building (such as a mural) or bas - relief sculpture; c) Decorative kick - plate, pier, beltcourse, or other similar feature; d) Hand - crafted material, such as special wrought iron or carved wood; or e) Other details that meet the purpose of the standards. 4. "Custom," "decorative," or "hand- crafted" elements referenced above must be distinctive or "one - of-a- kind" elements or unusual designs that require a high level of craftsmanship. 5. Alternatives will be considered provided the number, quality, and mix of details meet the intent of the standards. Detail examples: left image = Distinctive glass entry /corner feature, steel weather protection element, decorative wood paneling, and decorative tilework. Right image = Decorative door and decorative mosaic tilework. 182CDesignManual _PCDraft_Updated_CLEAN.docx 33 03/25/2014 Draft Southcenter Design Manual Detail examples: Left image = Steel and glass weather protection and large openable window, decorative lights, and colorful mural. Right image = Distinctive large glass patterned curtain -wall, decorative masonry, and decorative wood component. Detail examples: Left image = Display windows divided into a grid of multiple panes, custom weather protection, decorative masonry, and decorative lighting. Right image (residential building) = Decorative weather protection over the entry, decorative masonry, and decorative lights. SCDesignManual _PCDraft_Updated_CLEAN.docx 34 03/25/213 Draft Southcenter Design Manual 12. BUILDING MATERIALS AND COLORS Intent • Utilize durable, high quality exterior building materials that contribute to the overall appearance and longevity of the building, as well as colors and textures that reflect the local setting and further articulate the building design. Design Criteria A. Use of natural materials that reflect our Northwest setting such as stone, local woods like cedar and fir, and functional materials like concrete, brick, and metal are encouraged. 1. Descriptive Definitions and usage recommendations: a) Brick: Full size brick is preferable to thin veneer brick. When used, brick veneers should be mortared to give the appearance of full -depth brick and detailed with wrap- around corner and bullnose pieces. b) Ceramic tile: Glazed and unglazed tile should be limited in use to a facade cladding or decorative wall accent material. Simple color palettes and design motifs should be used. c) Fiber - Cement or Cementitious Siding: An exterior siding product available in planks, panels and shingles and composed of portland cement, ground sand, cellulose fiber and sometimes clay, mixed with water and cured in an autoclave. d) Fiber - reinforced plastics (FRP), cast glass fiber composites ( "fiberglass "): These materials are often used in molded reproductions of carved wooden or cast metal architectural ornamentation such as architectural columns, capitals and bases, cornices, and other trim. They may be used if their appearance closely approximates the type of painted wood element they are simulating, and are coordinated in color and composition with the selected architectural style. They should only be used at locations above the reach of pedestrians. e) Profile, Corrugated, and Other Sheet, Rolled and Extruded Metal Surfaces: Where used, sheet metal should be detailed with adequate thickness to resist dents and impacts, and should have trim elements to protect edges. Metal siding shall have features such as visible corner moldings and trim and incorporate masonry, stone, or other durable permanent materials near the ground level (first two feet above sidewalk or ground level). Metal siding shall be factory finished with a matte, non - reflective surface. 18 CDesignManuaI _PCDraft_Updated_CLEAN.docx 35 03/25/2014 Draft Southcenter Design Manual f) Stone (including river stone), stone veneers, cast stone, terra cotta, precast concrete, glass fiber reinforced concrete (GFRC). Improperly simulated or contradictory finishes (i.e. use of panelized concrete to simulate a riverstone wall appearance with visible straight -line joints cutting across individual stones) should not be used. g) EIFS (Exterior Insulating and Finish Systems): Close attention should be paid to detail and trim elements for a high quality installation. Very stylized or highly textured surfaces are strongly discouraged. Joint patterns should be architecturally coordinated with overall facade composition. These finishes should be sheltered from extreme weather by roof overhangs or other methods and weather exposed horizontal surfaces should be avoided. EIFS should not extend below two feet above the ground plane. Use concrete, masonry, or other durable material for wall surfaces within two feet of grade to provide a durable surface where damage is most likely. These two buildings employ EIFS as the predominate siding material, but employ masonry near the ground level which provides greater durability and contributes to the character of the buildings. h) Wood: Horizontal sidings such as clapboard and tongue -in- groove; vertical siding such as board and batten; and other horizontal sidings such as smaller wood shingles may be suitable. The larger, more rustic styles of shakes should not be used. Trim elements should be used for all wood siding types. Timber detailing and exposed bracing may be appropriate. "T1 -11" plywood panel siding is not allowed. SCDesignManual _PCDraft_Updated_CLEAN.docx 36 03/25/2185 Draft Southcenter Design Manual i) Precast Concrete: The location and spacing of panel and expansion joints should be incorporated into the facade composition. Castings should be shaped to form architectural profiles that create bases, cornices, pilasters, panel frames, and other elements contributing to facade composition and human scale. Cement type, mineral pigments, special aggregates and surface textures may be used in precast concrete to achieve architectural texture and variety. Poured -in -Place Concrete: Long surfaces of uninterrupted concrete walls should not be used. The use of textured form liners, pigments, stains, and /or special aggregates should be used to create visual interesting surfaces. At a minimum, the design of exposed concrete walls should incorporate the location and spacing of formwork tie - holes, expansion joints and control joints into the facade composition. The architectural treatment of poured concrete that is used as a building architectural base should be extended to concrete used elsewhere in the project for sitework material. j) k) Concrete Block: Incorporate a combination of textures to provide visual interest (such as split or rock - facade units and /or contrasting colored units with plain smooth block can create distinctive patterns). Decorative treatments such as alternating block courses of differing heights, contrasting grout colors, alternating surface textures (e.g. precision face and split face) and /or compositions of colored blocks should be used, along with matching cap and trim pieces. Plain concrete block fire walls on the sides of a building that are visible to the public are discouraged. 2. Local and recycled building materials should be used whenever possible. 3. If the building massing and pattern of windows and doors is complex, a simple palette of wall materials, textures and /or colors should be used. If the building volume and the pattern of wall openings are simple, additional wall materials, textures and articulation may be utilized. B. Use wall cladding materials appropriate to the architectural style and building type. Authentic materials and methods of construction should be used to the degree possible. 1. Where simulated cladding materials (e.g. artificial stone to substitute for real stone, or painted fiber reinforced plastics to substitute for painted wood) are used for reasons of economy, they should be durable and closely match proportions, surface finishes, and colors of original materials. 2. Fiber - Cement or Cementitious Siding: Planks are an acceptable substitute for wood siding when used in the formats described above under "Wood." To match the precedents of real wood siding in the area the spacing of siding should not exceed 8 ". 1 8eDesignManual _PCDraft_Updated_CLEAN.docx 37 03/25/2014