Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-001 - SC-4 RETAIL
SC -4 RETAIL 17275 SOUTHCENTER PY M07 -001 Parcel No.: Address: Suite No: Tenant: Name: Address: 2623049063 17275 SOUTHCENTER PT TUKW Owner: Name: MIKAMI MASAO Phone: Address: C /OWENDCO NW LTD TX DEPT , PO BOX 256 Contact Person: Name: CARRIE BOYD Phone: 425 - 442 -3843 Address: 9630 153 AV NE , REDMOND WA Contractor: Name: MERIT MECHANICAL INC. Phone: 425 883 -9224 Address: PO BOX 2109 , REDMOND, WA Contractor License No: MERITMI163CM Expiration Date: 06/01/2007 DESCRIPTION OF WORK: INSTALL 6 PACKAGE GAS /ELECTRIC ROOF -TOP UNITS; INSTALL 7 CEILING EXHAUST FANS WITH ASSOCIATED EXHAUST DUCTWORK; INSTALL 6 7 -DAY PROGRAMMABLE THERMOSTATS WITH 75 FEET CONTROL WIRE. Value of Mechanical: $70,000.00 Type of Fire Protection: SPRINKLERS doc: I MC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us SC -4 RETAIL 17275 SOUTHCENTER PY , TUKWILA WA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT OUIPMENT TYPE AND OUANTITY 0 0 0 0 0 6 0 0 0 7 0 0 0 0 * *continued on next page ** M07 -001 Permit Number: Issue Date: Permit Expires On: Steven M Mullet, Mayor Steve Lancaster, Director M07 -001 01/26/2007 07/25/2007 Fees Collected: $728.38 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 36 Thermostat 6 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 01 -26 -2007 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied The granting o • ' = permit does not, • the • erformance o +e :.-.., Signature: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Ag-M6vt Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M07 -001 Issue Date: 01/26/2007 Permit Expires On: 07/25/2007 Date: b1 kill lDI- permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. ume to give authority to violate or cancel the provisions of any other state or local laws regulatinc tho ' ed to sign and obtain this mechanical permit. Date: t—ae.f This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -001 Printed: 01 -26 -2007 Parcel No.: 2623049063 Address: 17275 SOUTHCENTER PT TUKW Suite No: Tenant: SC -4 RETAIL 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -001 Status: ISSUED Applied Date: 01/05/2007 Issue Date: 01/26/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M07 -001 Printed: 01 -26 -2007 fir+ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the Washington State Department of Labor and Industries is required for this project. 19: The Tukwila Fire Department has changed keybox manufacturers from Supra to Knox. Install a fire department Knox key box. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -001 Printed: 01 -26 -2007 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this • ermit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or pe ormance of work. Date: 1 r q,u - O 4 M07 -001 Printed: 01 -26 -2007 Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: tRow CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 WU 1 Building Permit No. Mechanical Permit No. Public Works Permit No. Project No. (For office use only) (o1- -i Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: ollf�cPi 3Ci t in 3 Site Address: 1-3-Q-16. , a(Jl7 CQ. r 1 � , 1 � c-¶3 Suite Number Floor: Tenant Name: cal ', "A k A A l�A ( J New Tenant: Yes ❑ ..No Property Owners Name: Mailing Address: Zip c11.930 ts Company Name: f e/ t'1 Mailing Address: C lQ3(1) Contact Person: vtrr c Contact Person: E -Mail Address: q:llpermits plushcc changes\pennit application (7 -2004) Revised: 6-8-05 bh City State CONTACT PERSON /�, o Day Telephone: nne: 1 5 42 S "' I' `, A 43 ( W �� t fN V o J , n City �S "" ta te Zip C�(.X C Fax Number: vJ g(..Q - Col to • GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) 1 E- City State V n 2 Zip d Day Telephone: -41 17S - YI J a yg E -Mail Address & At • MLA it. _I ' . 0 Fax Number:4 - �R -ogo a-- Contractor Registration ' umber: MAYO- MI V1600 Expiration Date: / 0 - 1— ©} * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Kekhond 1 M 1AM wsa- ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record State Zip City Day Telephone: Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: State Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Other Mechanical Equipment q: \\permits plus\icc changes\permit application (7 - 2004) Revised: 6 -8 -05 bh MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL MITRACTOR INFORMATION Company Name: ( r i &trv"T Olio l.Y P IX) i (d In.() Mailing Address: l r EO i t 5 Contact Person: LA • L 4 ' E -Mail Address: VII LLII ', lk _At I'. Contractor Registration Number: I+ rytp ILezeAf Expiration Date: 12- aI -113- * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Use: Residential: Commercial: Fuel Type: Electri Date Application Accepted: Valuation of Project (contractor's bid price): $ Scope of Worl lease provide detailed information): 1V\5Z(� U • New ... ❑ New ... Gas.... Indicate type of mechanical work being installed and the quantity below: BUILDING • • • OR AUTHORIZE e Signature: / 40r l - -o1 Page 4 City State p Zip Day Telephone: 47,c 83 -9 �a� • CCN✓1 Fax Number:' b . 3 - O o pack ■A Z Le tc U i 1 -ex AZANCCU o4,tkc kWO( 4 _ �' - mil C c �d y S (� w =tom -fe4- C r - le Ala ADVA 64 - Top Replacement .... ❑ Replacement .... ❑ Other: PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF P ' Y BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: Mailing Address: S (t2 /VZ li crit f l(M City Date: Day Telephone: 2- - 620 a - 3 State Staff Initials;n Zip Date Application Expires: i Receipt No.: R07 -00114 Initials: JEM User ID: 1165 Payee: MERIT MECHANICAL, INC. TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049063 Permit Number: M07 -001 Address: 17275 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 01/05/2007 Applicant: SC -4 RETAIL Issue Date: Amount Payment Check 22893 588.70 Account Code Current Pmts 000/322.100 588.70 Total: $588.70 Payment Amount: $588.70 Payment Date: 01/26/2007 11:47 AM Balance: $0.00 4162 01/26 9719 TOTAL 5188.70 doc: Receiot -06 Printed: 01 -26 -2007 Parcel No.: 2623049063 Permit Number: M07 -001 Address: 17275 SOUTHCENTER PT TUKW Status: PENDING Suite No: Applied Date: 01/05/2007 Applicant: SC-4 RETAIL Issue Date: Receipt No.: R07 -00020 Initials: BLH Payment Date: 01/05/2007 09:06 AM User ID: ADMIN Balance: $588.70 Payee: MERIT MECHANICAL TRANSACTION LIST: Type Method Description Amount Payment Check 22863 139.68 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City a Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 139.68 Total: $139.68 Payment Amount: $139.68 3484 01/05 9710 TOTAL 137.68 doc: Receiot -06 Printed: 01 -05 -2007 Project: f /,/ Type of Inspection: r/N l dcr Ad r / sd >/ 4fin/ Date Called: Special Instructions: Date Wanted: 7— i0-07 e n. Requester: Phone No: nio7 - k INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 Eit Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. COMMENTS: �'�"✓,�,��O nip f- i; 4 / Inspect Dat 2— /O -0 58 0 REINSPECTION E REQUIRE ' Prior to inspection, fee must be pa'. at 6300 Southcenter = vd., Suit- 100. Call the schedule reinspection. Re - pt No.: 'Date: Project S r — ��P /,f, / Type of Inspection: / U s �'114,T Ja�.LJi j Address: /7 Z 7 5 /I, —,,%, 4 •-- Date Called: Special Instructions: Date Wanted: - Z - off R'‹, Requester: o...., Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 1 : \ Date: 3 -2 -v? .00 REINSPECTION REQ�fD. Prior to inspection, fee must be B •aid at 6300 Southcenter vd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: .57 y ,Z r-T4 IL Type of Inspection; R�,,1 - ,:k, Address: / 7 2 ) , / , 4 / , - , - ''€/ Date Called: Special Instructions: Date Wanted: 2 ^ Z 7 — 0 — 7 p.m. Requester: Phone No: 'Ls - 5 G Zb INSPECTION RECORD etain a copy with permit INSPEC N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ENTS: !l dot, - ; �v - �n / ! /f��►1 / AJ f y�- 7 spector ipt No.: 0 REINSPECTION FEE EQUIRED. P at 6300 Southcenter Btv +., Suite 10 Da r to inspection, fee must be Call to sechedule reinspection. Date: Approved per applicable codes. Corrections required prior to approval. Pro'ect: .�'�'' - Y /e,-7W Type of Inspection: ype o Insp 4.96W4 4.96W4 V . -, A ) Address: X72 75 Date Called: Special Instructions: Date Wanted: 02 — ` a m- p .m . Requester: Ph a N� �,ZS — 44 7D3' INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. N i gl Corrections required prior to approval. COMMENTS: //•9,4.1) . 2,1 67/er r/rd f S L 1 / . 5 c1e -, 14'' 8y00 REINSPECTION FE REQUIRED. Pr r to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit 4W-60/] PER 206)431 -1 6 COMMENTS: — pry 4 v 4.0-I- Ok ri4 -- F ',,-, / U4 --- friecA4 ,1;Gu 1 F.,,c, I 01< Phone No.: - -- ) k , ° --, ).1 --- 23/k;. -- Th,s+ill h'fdfr41l1t d i4- k-)) wit- t ot- r;fe -r. I -, li,s- , ► Sp„ krn. R, re ' s. h co- door Permits: Occupancy Type: / Project: Sc — 12 C4 1 Type of Inspection: S FA, Pe' in F,n Address: Suite #: / '1 r s c Pu � ic i Contac Person: M; ire She p , Special Instructions: Phone No.: - -- ) k , ° --, ).1 --- 23/k;. Needs Needs Shift Inspection: /j,4 — •- Sprinklers: Y Fire Alarm: Al 4 h „G ► Hood & Duct: ,t) Monitor: A- /6,, CP, -,- Pre -Fire: Permits: Occupancy Type: / INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT ((,-S- 1) 1 UC F — /ca MO7 -Co I PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 g Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 Corrections required prior to approval. n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Inspector: 3"/ Date: 3 - - 7 Hrs.: ENGINEERS NORTHWEST, INC., PS. STRUCTURAL ENGINEERS • 6869 WooDi.AwN AvE. N. F.., SEA'n7E, WA 98115 (206) 525 -7560 FAX (206) 522 -6698 REVIEWED FOR CODE COMPLIANCE JAN 2 2 2007 CI Of lUkwlIa BUILDING DIVISION SC4j:etajI Tukwila, WA STRUCTURAL CALCULATIONS April 13, 2006 IDPIES 0 008 1 Fae c RECEIVED JAN - 5 2007 PERMIT CENTER MO1-oo( ENW ENGINEERS NORTHWEST, INC., P.S. — STRUCTURAL ENGINEERS 6869 Wooauwx AVE. er N. E., 105, SEATTLE, WA 98115 (206) 525 -7560 FAx (206) S2 -6698 PROJECT # PROJECT C -9 2e- / DATE s j Zg'e' SUBJECT /-Atr"/ SHEET S - /OF /A7 t1117= iliE �•i •1 � ;r��. -- -- ■ tea __ Jl' JIB"'' " 11 1'w !1Natar', SOW . y Zy AL s • /•3 cc • • • • • It t► otc / 6' O: *or . •j 'pi's -- 40/ " :L 6 "en -all Q*'/ 9ke • ?•P • • • .4 , 1 1 Vot '211 g‘e r ( .5 A$ dO .. .S 133HS 31Va / f1/ i / 13 •75 11aradct 8699 ( 9 0 0 XY d O9SL-SZS ( 9 0 6 S 1186 V A A ' 1 V S 'SOU • '3 'Li 3 W NMw1000AI 6989 • imams SS33NION1 7V111113111LLS — •S'a `'3NI `,MAMMON SU NIONN a ENW ENGINEERS NORTHWEST, INC., PS. - STRUCTURAL ENGINEERS 6869 W000I.WN Ms N. E., #205, SEATTLE, WA 98115 (206) 525-7560 FAx (206) 522-6698 PROJECT # �� P PRJ Roicr S ' �f /Z� - DAZE 3 -Z4V.O SUBJECT K-Ocr SHEET 3 OF BY 7r. 4tgi.3 sv 3G�Z /0. , "- / /•S` IL a-Y 111. ya 36' •.v, N -1 4,3 56 ° ?A' //did. • • • • • • • • • ¢ , .0.Q / • • • • • • • • • • • H83 X84 -> E-- XB4 X85 -- ) SA1 2 - 3)K 240/16 0{ J9 SA1 HB5 36 ; 7N 11.5K - G1 Ac- 497# / ✓\/\/ r 4 30K 240/160 - J15 11.8K ADLOAD - :OK 240/160 - J10 4 - 3)K 213/144 - J11 0.8K ADLOAD .1K ADLOAD cir El N� <--- X84 X85 -) m r .- T a .4o 4g Y NI Y N C4 r: Pi 7 Y )L '''- M M . M 20' -0 4 nuc JOIST BILL OF MATERIAL JOB: SC-4 RETAIL LOC: T I MLA. WA E Owatlaptt NA I TIN I lacy 0 -2 Mali MIULUIll 0- /0112] ©E111 = Ell UM MI IMI NM MN Kali MI UM MEMO I IIIIMIFil ULU MIMI MI NI I 111= MO MI I 1Likl MI UM IN 0- ' ■EIit]©EIL1 MINIM i Il Ell MI IOU WI LEI ■ =LI II MIA ©EIi —MI MI IN MINIIIIII =I MIMI 21':11".!L.iL'i7MIA: rr�u73411.:1!41;' Mt J13 J14 J15 J17 J13 J17 30 K 240 /160 ay 3 30 K 240/160 J1 30 K 2401160 21 30 K 213/144 ctwcJ lE1C1D.r REIM* 41 -6 114 41 -6 114 1, lareh 44 -312 44 -31/2 41 -614 41 -8 114 41 -8114 41 -6114 42 -6114 42 -6114 0 -2 1CInPia MMIAdiras No R'a601141 IWO,. It tEdd71ps 1R. REIM'S*, It — Ko Aloft w R OA l51kmecidEd Rai ON. 212 2112 212 212 COLORCODE USTMIABER FILE NUMBER 5 SHEET OF 880-06-0711 PIECE COUNT PRIMER OOLOR REFER TO DRAWING 14 2112 212 212 212 2121 212 GRAY 4R Ead bete PMgels R 9419 rts dlla* - `^'\,R a. El J-1 VULCRAFT GROUP 82200813.48 V4dcmft 80M 7.0 SEQUENCE: DESC: JOST TYPE: 1,'�aZh7F tJt�y "�5 emmiitEET QUANmY J13 J14 J15 J18 J17 . Ifted rOalr 6wrdRdlApsed AAas MAX U. DEFL= LINO 3116' BEARING SEAT WELDS DETALER WA DETAIL CHECKER DATA PROCESSING: OATA PROMISING CHECKI3t END: SHOP ORDBt SHOP ORDER CHECKER: CAR E-31 A 113.1 45104 J 3T T3� 3 300 711 11 me stir 711 116k 457 ,r -1, 5 R OL 006 7N IOAk C-3.1 I 305 711 11.04 - --.J L. O --.J L•-- . 1 .7 .1 CAMQr TEEP.I. SEE O ROOF FRAMING PLAN O to f 9 Z0r TCP OF LRLYWO Q24131CN (La PLYODDD) 4 .— ) mum 10P OT POPPET WALT= ABOVE MTUM. 3.) C01ORA010R AND TRUSS SUMER TO VERIFY 1{/O A DAS AND LOCATIONS. a�.17 .MIST LOADS ARE Tats SOK J21O/ / `NET Imo ADD ODD/ ACS LOAD AI' 7.1.. PANEL POINTS OESKNt M WC N ACUCCN W ADD WAD. is.) 70K A06 • 2741( E00/.• CPNCPV WALL 11L'4 •• /41 NU 111!11 E1. 15.-CP ppit ADD ow/ AOO LOAD AT 7.1. laMEl PONE. NDT NE9URkV law CAMPY. ) OESIG11 TOP NOG 51 A ON 10 CO A 1111.0. �1 10P p1Q1� �a 211,4M OE.SLGtttD r. Af ARiMGUM� O OF 13200/ lOW CARRIED PM J015/SEAT. O X- ORACES MOM THE( ) ARE WALED CN 53.2 LEDGER 07 -02 -2007 CARRIE BOYD 9630 153 AV NE REDMOND WA 98052 RE: Permit No. M07 -001 17275 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/29/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Ter Marshall, Permit Technician xc: Permit File No. M07 -001 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: B i d 1g Division it Complete gl Documents/routing slip.doc 2-28-02 � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 - 001 DATE: 1 -5 -07 PROJECT NAME: SC-4 RETAIL SITE ADDRESS: 17275 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # before Permit Issued 5!I Altt9G 1 v 117 Fire Prevention Public Works ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1 -9 -07 APPROVALS OR CORRECTIONS: Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions 0 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Planning Division DUE DATE: 2 -6 -07 Not Applicable ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V PRESIDENT 02/14/1984 Bond Amount KIRKWOOD, JOAN M SECRETARY 02/27/2006 FRICKBERG, WILLIAM MICHAEL VICE PRESIDENT 02/27/2006 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License MERITMI163CM MERIT MECHANICAL INC CONSTRUCTION CONTRACTOR 600517946 46817500 CORPORATION PO BOX 2109 REDMOND KING WA 980732109 4258839224 ACTIVE GENERAL UNUSED 2/14/1984 6/1/2007 AUTOMMC044QH https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MERITMI163CM 01/26/2007 TAD WYE & 11009. BED:RPAON LOMB CAi - EP RPII 91. AFUE % 1E OOIAROL REIMS AIDS WAIN IF -I AMR KING M(90 CITING FJOWHST FM TOILET ROOMS 90 025 640 0.42 110 -1 -60 22.8 ucw SNITCH 2000 EF-2 AMR IWG *90 CEILING ccIWHST FMI TOW ROOMS 90 0.25 640 0.42 110 -1-60 22.8 _.� LIGHT SNATCH _ U-3 AR KING MO CUING EXHAUST FM TOM.ET ROOMS 90 025 640 0.42 110 -1-60 22.8 LKIR SWITCH BELT ff - -4 AR KING *90 CUING DUALIST FAN TOUT ROOMS 90 0.25 640 0.42 110 -1-60 22.8 0001 SWITCH ERN&: TSC1201R1A -00 EF -5 III KONG AK90 CMG EXHAUST FM TOILET ROOMS 90 0.25 640 0.42 110 -1 -60 22.8 WAR SWITCH 208 Er-6 AMR KING AK90 CLING EXHAUST FAN TOILET ROOMS 90 0.25 640 0.42 110 -1 -60 22.8 LIGHT SWITCH 1135 EF 7 MR KING MO CEQNG IMPOST FM JANITOR ROOM 90 0.25 640 0.42 110-1-60 229 LIGHI SNITCH I, 2, 3 1.2.3 TAG MAKE & MODEL DESCRIPTION CFM FM COouNG. LW TOTAL /SENSIBLE SEER HEAIING.11811 NT/OUT AFUE % ELECTRICAL wEICH1 IBS REMARKS SA OSA ESP RPM HP OINK vou'Pli SNOEWKER RD AICA IWCP A/C-I TRIBE: YSCO60MRIA -D1 ROOFTOP GAS/ELECT. 2000 200 1' 1135 1 BELT 63.2/48.3 10.2 60/48 8d 208 3 16.3 25 741 I, 2, 3 A/C - 2 TRM1E YS0060MRIA -01 ROOFTOP GAS/ELECT. 2000 200 1' 1136 1 BELT 632/483 10.2 60/48 80 208 3 16.3 25 741 1, 2, 3 A/c-3 ERN&: TSC1201R1A -00 ROOFTOP GAS/ELECT. 3200 320 1 1135 1.5 BELT 104.9/80 10.1 120/972 80 208 3 24 30 1194 1, 2, 3 A/C- -4 TINE Y9C1204R1A -00 ROOFTOP GIAS/ELECT. 3200 3000 320 300 1' 1' 4 913 1135 1.5 15 8EU BELT 104.9/80 94.9/72.1 10.1 10.1 120/97.2 120/972 80 80 208 206 3 3 24 22.6 30 35 1194 1057 I, 2, 3 1.2.3 A/C -5 IMRE: Y50090MRIA -00 ROOFTOP GAS/ELECT. A/C -6 TIME: YSC0901A�4RIA -0O ROOFTOP GAS/ELECT. 3000300 + 1' 913 135 130.T 94.9/72.1 10.1 120/97.2 80 208 3 22.6 35 1057 I. 2, 3 sill WYE a VIM Ileac SIZE FACE WE all PAMI1 BORDER MOWING RBII MS an TINS MS SEE PLAN SEE PIM SEE PUN 4-WAY T -BAR URIC BORDER 3 CO2 SNOEWKER RD SEE PIM SEE PLAN SEE PUN 4 -WAY SURFACE TO DUCT SDI TRUE 300 RS SEE PUN SEE PUN SEE PIM O. DEM SURFACE WALL BORDER 1 W/ 08D MT TRUES 50F SEE PIM SEE nix SEE PIM LATTICE T-BAR CELTIC PMEL ONLY 161 11 [IN 50F SEE FUN SEE KM SEE PLAN LATTICE T-BNR CEILING PMEL ONLY 1G2 TINS 3601E SEE PUN SEE PIM SEE PLAN DEFLECT= SURFACE WALL BORDER 1 COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. rimsE 120 1 1 60 17275 SOUTHCENTER PARKWAY TUKWILA, WA RECESSED MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX (425) 867 2 0962 UCENSE: MERITMI1 63CM REVISIONS 1. IMO Re WIll 1 -03 -07 - GJF JAN - 5 2007 PEM::=f' GENIL- DESIGNED MIF CHECKED AEA DATE 12 - 26 - 06 JOB TIMER 906107 SHEET TITLE COVER SHEET & SCHEDULES SLEET TINIER M 1-OF -3 SIC WYE a DM. SEI MINX CONTROL Pena liv VOLT Lit 13111-1 Q -MARL( 52268 R15ER ROIL[ 1.5 rimsE 120 1 1 60 T -STAT RECESSED r % • Ak UNIT SCHEDULE NOTES: 1. EQUIPMENT WAY BE SUBSTITUTED FOR EQWAI. OR BETTER WINIFACTURER. 2. WITH LOW/111 PRESS SHTICK CRANKCASE HEATERS ROOF CURB . SELECT ESP 0 1 d o BELT OTUVE MOTOR. 3. SMOKE DETECTOR. ECONOMIZER w/ BAROMETRIC RElEF EXHAUST FAN SCHEDULE NOTES: 1. EQUIPMENT MAY BE SUBORNED FOR EQWL OR BETTOR MANUFACTURER. ELECTRIC WALL HEATER SCHEDULE NOTES: 1. EQUIPMENT MAY BE SUBSUMED FOR EQUAL OR 8ETTO1 MANUFACTURER. GRILLES. REGISTERS. DIFFUSERS SC}IEDULE ROOF UNE SCALE: 1/i!' a 1 -0 DIMENSIONS FOR AC- 1 & 2 SOLE: TOE SOUTH ELEVATION i i 8-5/% T8 -I/2 IRK IE U =4o-7% SCOPE_ OF WORK INSTALL 6 PACKAGE GAS/ELECTRIC ROOF TOP UNITS. INSTAL 7 CEM O EXHAUST FANS MATH ASSOCIATED COWIST DUCTWORK. INSTALL 6 7-DAY PROGRAMMABLE THERMOSTAT MATH 75 FEET OF CONTROL TARING. IFAILDESCRIEMON PARCEL 12623049063 46 -3/8- DIMENSIONS FOR AC -3 THRU 6 sOa . HOLE SRI_ LOCATION 3170th St ;SJla2ridSt 02006 Mapaued. Int. I SEPARATE PERMIT r.:QUIRED FOR: v echanks lef umb r s City of Twkwila BUILDING DIVISION i S 163rd PI ` -... i i Ian review the i Of app cpprovai Is subject to ems and minion. c:nctrixtion �� ordna Hc. Matt AIM BY REMUS [:o c::anges shall be made to the scope without prior approval cf Tta3'i!t+� Divis:3n r v : : ::r.3 v4 :I require a new plan submiUaI and may Inciude additional plan review fees. I K i N • Camerae or S 4`1 AC UNIT CURB DETAIL NO SCALE 1 S 180Th St = �► y P D Dr Is, v u Mend Dt City ofltkwfa BUILDING DIVISION STRUCTURAL 111343ER OW GENERAL) Cost.° Dr o i' REVIEWED FOR CODE COMPLIANCE p ormA TEA JAN 2 2 2007 i Of Tukwila BUILDING DIVISION ABBREVIATIONS COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD ORANINGS OF ACTUAL NSTNIADON SWNIL BE FRONDED TO THE BMOC c,Et semi 90 DAYS OF THE DIVE OF SYSTEM AOCEPTMICE PER WASH! STAN DUCEY CODE (wISEC) SECTION 1416:1 NI OPERATION MANUAL MO W11IEWWCE MANUAL SHALL BE PROVIDED TO WE BUILDNO OWNER PER WSW SECTION 1416.2. ALL WPC SYSTEMS SHALL BE BOUNCED AND A NIMBI 8KANCE REPORT SIWl BE PRONGED TO THE OWNER PER 1/SEC =MN 1416.3. IWM CONTROL S=TET SHALL BE TESTED, CALIBRATED AND PAIUSIED, SEQUENCE'S OF OPERIA110N SKILL 8E TESTED TO ENSURE THAT THEY OPERATE N ACCORD NTH SPECIFICATIONS MD APPROVED PUNS. AID COMPLETE REPORT OF TEST RESULTS SHALL BE FLED ono* OMAER PER MSEC SECDON 1416.4.1. AND 1416.4.2 GENERAL NOTES 1. VERIFY LOCATIONS OF THERMOSTATS WITH OWNER. 2. HVAC EQUIPMENT WEIGHTS AND LOCATIONS TO BE APPROVED BY THE STRUCTURAL. ENGINEER. 3. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. 4. CONDENSATE DRAINS TO BE DISCHARGED ON SPLASH BLOCKS. 5_ MAINTAIN A MINIMUM OF 10 FT DISTANCE BETWEEN OUTSIDE NR INLETS, PLUMBING WASTE VENTS. EXHAUSTS. COMBUSTION AIR OUTLETS AND DRYER OUTLETS. 6. USE TOTALINE SIGNATURE ICPV230 7 -DAY PROGRAMMABLE THERMOSTAT. DUCJWORK - LEGEND - I 0 011 0 0 ►�� ICS 0 R - 100 S - 100 E -- 100 SISTA .�..� FO W I • I Mw± 3' r VD AIR FLOW DIRECTION SUPPLY OR OSA DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR RETURN. RELIEF OR EXIWlST DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN OR AWAY ROUND. RECTANGULAR RETURN. RELIEF OR DC HAUST DUCT SECTION DOWN OR AWAY FROM ROUND. RECTANGULAR ROUND DUCT SYMBOL RETURN AIR; NUMBER INDICATES CFMA QUANTITY SUPPLY AIR; NUMBER INDICATES CFM QUANTITY EXHAUST AUST AIR; NUMBER INDICATES CFM QUANTITY SOUND UNED SHEET METAL FLEXIBLE EQUIPMENT CONNECTION VOLUME DAMPER RRNNG MMES ROUND TO ROUND 4S 1111NG SQUARE TO SQUARE 4S RUNG SQUARE TO ROUND 45' FITTING 45' HUNG Foe DUCTWORK ABV. A.D. AP. A.F.F. AH BF DOT CUP CLG CO CG CTG CONC. CONFL CFU DUFF DIAL ON DWG. DES EA. ENT. EAT EMIT EQUP' EXW ESP FIR FT. FPM FUT. GALV. GR. HUG IMIC NR. HP ABOVE ACCESS DOOR ACCESS PANEL ABOVE FINISHED FLOOR AIR HANDLING UNIT BELOW FLOOR BOTTOM CAST IN PLACE CQJNG CEILING DIFFUSER COU NG GRILLE CQANG TRANSFER GRILLE CONCRETE CONNECTION CUBIC FEET PER MINUTE ORTUSER DIAMETER DRAWING ORY BULB EACH ENTERING ENTERING AIR TEMPERATURE ENTERING WATER TEMPERATURE (QI ATHENS EXHAUST EXTERNAL STATE PRESSURE FLOOR FOOT or FEET FEET PER LATE FUTURE G/ILVNlZE GRIM HIGH WALL GRILLE I I WAIL TRANSFER GRILLE HEIGIff HORSEPOWER TD IE INL. WG LLN. DUFF UN. FT. LWG LWR MAX. MEN MN. MOT. DPI. AHD N.C. 14.0. OSA 000 OD PCF POC PSI PSIG RPBP RFA REG. REQ'O RA SO FT. SA S.L- TOH TG TOT TYP VTR W EI WIG W/ WE►/Ql INSIDE OIAIAETER /OIUENSION INVERT ELEVATION INCHES W.G. UNFAR DIFFUSER LINEAR FEET/FOOT LOW WALL GRILLE LOW WALL REGISTER MAXIMUM 1000 BRITISH THERMAL UNITS MINIMUM MOTORIZED DAMPER MOUNTED NORMALLY CLOSED NORMALLY OPEN OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE POUNDS PR CUBIC FOOT POINT OF CONNECTION POUNDS PER SOUAARE INCH POUNDS PER SQUARE NCH GAUGE fifieltiMPRESSURE BACICFLOWI< PREVENTOR REGISTER REQUIRED RETURN AIR SQUARE FEET SUPPLY RR SOUND LIED TOTAL DYNAMIC HEAD TRANSFER GRILLE TOTAL 11fP11E'JIL VENT THROUGH ROOF TILT MB WATER GAUGE WITH WiHOUT MD1-O • COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBUCATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. rAl 'vi MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX (425) 867- 0962 LICENSE: MERITMI 163CM REVISIONS 1. FSSLR D RR FEW 1/03/07 - G1F 1 RECEIW :0 PER' % CEN I t ± DE8I61�D GJF CHECKED AEA DATE 12/26/06 Jos UMBER 906107 SHEET TITLE HVAC PLAN MAIN FLOOR SIERT NUM= M-1 0 2 --0F -3 t • • ........ .............. ON ROOF 5-TON 691 LDS 60 IMO 24x24 RG1 1800 CFM 24x24 RG1 1800 UV 12 CO1 500 CFM DPOF4 ON ROOF 5-TON 691 IBS 60 KU 12 CO1 500 UV DP OF 4 10"0 CO1 24,24 RG1 1450 CFM DPOF2 ON ROOF 8.56 -TON 1155 IBS 120 MOH 12 CO1 625 CFM 1W OF 4 15 CO1 8000V 11POF4 12x12 TG1 1WOF2 14'0 CO2 625 UM 1W OF 4 1 -1/4' UNDER ROOF NEW RA DUCT WI 1 SL 14 CO27S0 CFM TIIP 1602 SOt 400 CFM 34x16 RETURN OPQING ON TOP SOH SUIEDI 2700 UM ON ROOF 73-TON 1076 IBS 120 MON ON ROOF 73-TON 1076 IBS 120 MOH 6 CO2 100 011 1 -1/4' UNDER ROOF 12X12 TG2 IIIGH 00111 SCES INAC RAN — UAW FLOOR Salk i/r • 1 CONSTRUCTION NOTES: 1. GAS PANG TO 8E ROVED BELOW ROOF TIGHT TO SIRUC1URE. 2. INSTALL 4 FOOT DUCT DROPS FROM ROOF TOP UNITS FOR SUPPLY Art me RE1m AR 3. DU CTWORK SIZE TO MATCH CURB OPDi1GS. 4. PROVIDE 75 FEET OF SUNG FOR 11IAIOSTAT. S. VERIFY T -STAT LOCATION %OH TENANT PRIOR TO ROUGH N REVIEWED MP�►NC CODE CO i0 0 nn v 1) ' JAN 2 2 1001 city Of Tukwila BUILDING DIVISION Mop -ooI • I I r • • , • 1 8.5 -TON 1155 IBS 120 118H 8.5 -TON 1155 IBS 120 118H 7.5 -TON 1076 LBS 120 LEE 7.5 -TON 1076 LBS 120 MI • 60 FT TO PROPERTY UNE • ✓ r ✓ r 1 • 8'A UP 1111W ROOF TO VENT CAP. ✓ r ✓ r r • • • ✓ r 1 r 37.5 FT TO PROPERW UNE 8'0 UP THtU ROOF TO VENT CAP. IWMC PUN - ROOF LEVEL S 1 le _ , - -0- 500+ FT TO PROPERTY LINE s s • • 8'0 UP TIM ROOF TO VENT CAP. 60 FT TO PROPERLY UNE GAS METERS DUN/ PRESSURE BY OTHERS. CONSTRUCTION NOTES: 1. GAS PANG TO 8E ROWED BELOW ROOF TDGHT TO SIRUCIURE. 2. INSTALL 4 FOOT DUCT DROPS FROM ROOF TOP UNITS FOR SUPPLY MR AND RETURN AR. 3. DUCTWORK SIZE TO WITCH CURB OPENINGS. 4. PRONOE 75 FEET OF DUNG FOR THERMOSTAT. I REVIEWED FOR I CODE COMPLIANCE ( JAN 2 2 MI • Gty Of Tukwila BUILDING DIVISION . Mop -on COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. REVISIONS 1. wite RIR POUT 1/03/07 - GJF CHECKED GJF AEA DATE •TORS M1111BER 906107 SHEET TITLE 8/03/06 3 -OF -3 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX (425) 867 -0962 LICENSE: MERITMI163CM HVAC PLAN ROOF FLEVEL p@R RUINER M-2.O • 1