Loading...
HomeMy WebLinkAboutPermit M07-015 - CHER'S AND MALASADASCHER'S AND MALASADAS 14624 TUKWILA INTERNATIONAL BL EXPIRED 10-03-07 M07 -015 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 0040000901 14624 TUKWILA INTERNATIONAL EL TUKW CHER'S AND MALASADAS 14624 TUKWILA INTERNATIONAL BL , TUKWILA WA FRIENDLY FUELS INC 1190 SUNSET BLVD SE SUITE F , RENTON WA Contact Person: Name: DALE HAWKSWORTH Address: PO BOX 24321 , SEATTLE WA Contractor: Name: AFFORDABLE HOOD INTSALLATION INC Address: 2963 FIRST AV S , SEATTLE WA Contractor License No: AFFORHI951BS MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: INSTALL TYPE 1 HOOD WITH EXHAUST, DUDCT WORK , EXHAUST FAN AND MAKE -UP AIR. Value of Mechanical: $3,450.00 Type of Fire Protection: NONE Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC - 10/06 EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 1 0 0 * *continued on next page ** M07 - 015 Steve Lancaster, Director Phone: Phone: 206 999 -5163 Phone: 206 -382 -0160 Expiration Date: 01/12/2009 Steven M. Mullet, Mayor M07 -015 03/01/2007 08/28/2007 Fees Collected: $201.56 International Mechanical Code Edition: 2003 Boiler Compressor: 0 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 03 -01 -2007 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie doc: IMC-10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M07 -015 Issue Date: 03/01/2007 Permit Expires On: 08/28/2007 Date: CI D I l (1' permit and know the same to be true and correct. All provisions of law and ordinances r specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the perfo ance of work. I am authorized to sign and obtain this mechanical permit. Signaturej, Date / U Print Name: - G2l12,, 11 Wet ctIke S GV Cti This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 - 015 Printed: 03 -01 -2007 Parcel No.: 0040000901 Address: Suite No: Tenant: 14624 TUKWILA INTERNATIONAL BL TUKW CHER'S AND MALASADAS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.cidukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -015 ISSUED 01/31/2007 03/01/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (206/296- 4928), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the doc: Cond -10/06 M07 -015 Printed: 03 -01 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Building Official from requiring the correction of errors in the construction documents and other data. 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooling appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, 1FC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 17: All new automatic fire- extinguishing systems and all modifications to existing automatic fire- extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 18: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooling equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 19: Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Non - required fire protection systems and equipment shall be inspected, tested and maintained or removed. (IFC 901.6) 20: Local U.L. central station supervision is required. (City Ordinance #2051) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 22: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department job Number available to confirm shut down approval. (City Ordinance #2051) 23: An electrical permit from the Washington State Department of Labor and Industries is required for this project. 24: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 25: These plans were reviewed by Inspector 515. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -015 Printed: 03 -01 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: ' < l O doc: Cond -10/06 M07 -015 Printed: 03 -01 -2007 SITE LOCATION H( ! si m i 6. Tenant Name: t .'I/t 6 /"At c7 14A1k14Mr ehle -tard evAipt . Property Owners Name: P UA1fl . / J 1 J f 1 Site Address: Mailing Address: Name: CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citulcwila.wa.us Diz- (co w>a?4 Mailing Address: P.O. &51 2/32-1 E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** i t■ -• i Asi Contact Person: E -Mail Address: Contractor Registration Number Building Pe c No. Mechanical Permit No. MO1 01 ' Plumbing/Gas Permit No. Public Works Permit No. Project No. King Co Assessor's Tax No.: ebili:45 t 9t, / Suite Number: Floor: City CONTACT PERSON — who do we contact when your permit is ready to be issued City or o , j t ce use onl New Tenant: ❑ Yes X..No A State Zip Day Telephone: Z 979 , 2763 State Zip I(Fax Number: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 - 2006 bh Zip Page I of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct / Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind • [MECHANICAL PERMIT INFMATION — 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: 1 _ . t•II i�7. lb A J, O, l 2/321 e Ort ,I34/ City State Contact Person: �: �- �,.1Ci� �(1�L1. Day Telephone: �� ; f E -Mail Address: _ (v a� l ���L ., �l Fax Number: Contractor Registration Number: A¢-1i /'�l�'J 0'5 Expiration Date: Valuation of Mechanical work (contractor's bid price): $ eiel d Scope of Work (please provide detailed information): /%&712..G k 1 flak* Lr'/ elf-APP Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ...' ILL Replacement .... ❑ Fuel Type: Electric ❑ Gas .... ❑ Other: N,44 Indicate type of mechanical work being installed and the quantity below: Q: ApplicationsWovns- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW1WTORA0 D�� Signature: Print Name: 1 Mailing Address: Date Application Accepted: 23 /4/-e7 Q:\Applications\Forms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Date: 1-34.,--4b7 State Zip Date Application Expires: Staff Initials: Page 6 of 6 1 Receipt No.: R07 -00303 Initials: JEM User ID: 1651 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http :• / /www.ci.tukwila.wa.us Parcel No.: 0040000901 Permit Number: M07 -015 Address: 14624 TUKWILA INTERNATIONAL BL TUICW Status: APPROVED Suite No: Applied Date: 01/31/2007 Applicant: CHER'S AND MALASADAS Issue Date: Payee: AFFORDABLE HOODS INSTALLATION, INC. RECEIPT Payment Amount: $167.25 Payment Date: 03/01/2007 12:19 PM Balance: 60.00 Amount Payment Check 001461 167.25 Account Code Current Pmts 000/322.100 167.25 Total: $167.25 7' 7/01 TOTAL doc: Receiot -06 Printed: 03 -01 -2007 Receipt No.: R07 -00142 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0040000901 Permit Number: M07 -015 Address: 14624 TUICWILA INTERNATIONAL BL TUICW Status: PENDING Suite No: Applied Date: 01/31/2007 Applicant: CHER'S AND MALASADAS Issue Date: Initials: BLH Payment Date: 01/31/2007 01:22 PM User ID: ADMIN Balance: $167.25 Payee: AFFORDABLE HOOD INSTALLATION INC TRANSACTION LIST: Type Method Description Amount Payment Check 1434 34.31 Account Code Current Pmts 000/345.830 34.31 Total: $34.31 Payment Amount: $34.31 73 ?,• 01/a 9716 TOTAL 34 doc: Receiot -06 Printed: 01 -31 -2007 COMMENTS: Type of Inspectiop: S /L d fv d; »/( 4/1'/7 rr-P peU,/e/ Address: /y 2 G/ 7.r Date Called: Special Instructions: Date Wanted: - G - Q a, p.m. Requester: Phone No: o2( -2 ? / — /G/? Project: n % y ef /2Z /n S4(/4 Type of Inspectiop: S /L / Address: /y 2 G/ 7.r Date Called: Special Instructions: Date Wanted: - G - Q a, p.m. Requester: Phone No: o2( -2 ? / — /G/? INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERM ) 1 -36 Approved per applicable codes. EiCorrections required prior to approval. In ect r 4/t E] 8.00 REINSPECTIONFEE REQL ED. Prior to inspection, fee must be aid at 6300 Southcent r Blvd. uite 100. Call to sechedule reinspection. Receipt No.: Day: G Date: Project:. , ( KJ �h v Type of Inspection: /V 0 (.11 I Jl Address: �� ��� Date Called: Special I nst tion Date Wanted: 3 -/S--07 P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 431 -36X,0 COMMENTS: Approved per applicable codes. Ij Corrections required prior to approval. ri $58.a6REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: ("1.--7,e2 Type of Inspection: _ ,0f�* ihS 4 �./, Address: _� Date Called: Special I Date Wanted: ,3-/c--62 41 p.m. Requester: Phone No: INSPECTION NO. • INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Bivdr, #100, Tukwila, WA 98188 (206 431 -3 70 COMMENTS: Approved per applicable codes. D Corrections required prior to approval. ri $58.00 REINSPECTION F'�E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: Type of Inspection: Address: / TJ'' Date Called: Special Instructions: Date Wanted: — 37 / S P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTIO NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 /I/I D7-o /S` PER IT NO (206)431 -36710 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: &t , _ — Date :3_ c- El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Pr , (/ / i�ii�A� Type fInspection: �J (!� // s/ T / Gf , Address: l y42 77:re Date Called: Date Wanted: 3-_ /3-07 �m� p.m. Special Instructions: Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4> 9- 6 h l,,� / 1 / --(7 El $58.pQ..R1=INSPECTION F'E'D REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: A ( d / 4 J.% Type of Inspection: 70/ 4, 4 4 .4 % Address: / (16 o T%3 Date Called: Special Instructio Date Wanted: / Vn 7 Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. IT PE (206)43 1 -3670 !W Corrections required prior to approval. COMMENTS: P rz, s �� n h* t Zt) /17 e El $58.00 EINSPECTION FEE/REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: q) Project: , Cita-i." r.. ii . Me /cool* , Type of Inspection: L / 0, �r,�, Addrgs� y / � Date Called: Special Instructions: Date Wanted: — /3i / 37 Requester: Phone No 07/ '"/‘ ` 2_ El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,4407- -o /.' (206)431 -3670 Corrections required prior to approval. COMMENTS: /y€ d c-4 ri $58.0bAEINSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: • Public Health o' Seattle & King County HEALTHY PEOPLE. HEALTHY COMMUNITIES. Dorothy F. Teeter, MHA, Interim Director and Health Officer December 27, 2006 Cherilyn Williams 11020 Crestwood Dr. S Seattle WA 98178 CI Of Tu'kwiIa �,I RE: Che Ono Malasad s t Tukwila International Blvd, Tukwi , SRI134548 P/E 6702 (Risk 2) Dear Ms. Williams: The plans and specifications for the above remodel project (installing hood system, commercial dishwasher, pre - rinse sink, and direct plumbing to and from the public water system) have been reviewed and, in accordance with the provisions of Title 5, the Code of the King County Board of Health (The Food Code) are hereby APPROVED and subject to the following conditions: • Floors, walls, and ceilings must be smooth, easily cleanable and non - absorbent. I strongly recommend installing stainless steel or aluminum behind the fry station and dishwashing areas. Your establishment has been assigned the following plan review service number (SRI134548). Please use this SR# in all future contact with us. As required in The Food Code, upon completion of the construction and before opening for business, the food service establishment operator /owner shall: 1. Complete the enclosed application for the annual operations permit if you don't have a current permit. Include a copy of this letter when applying for the annual permit. Please call me prior to paying for your permit to verify the correct fee. Be advised that the penalty for commencing operation of a food service establishment without the required permit is 50% of the applicable permit fee. 2. Obtain a preoperational inspection approval. Contact me at 206 - 205 -1903 at least one week in advance to schedule a preoperational inspection. Be sure all other inspections (plumbing, building, etc.) are done before you call the Health Department for an inspection. Your application for a food service establishment permit from Public Health Seattle & King County may be approved during this inspection, however it is the responsibility of the food service establishment operator /owner to obtain all necessary permits and approvals from other agencies. Operating the establishment without these required permits or approvals may subject the operator /owner to legal action by the appropriate agencies. If the establishment is opened without the Health Department preoperational inspection, it may be subject to closure. Failed preoperational inspections will require a $100.00 fee for a repeat inspection. If you have any questions, please don't hesitate to contact me. Thank you for your compliance in this matter and I look forward to seeing you soon. Sincerely, DAB Enclosures Diane Agasid Bondoc, R.S. Plans Examiner Alder Square Office Alder Square Environmental Health Services 1404 Central Avenue South, Suite 101 • Kent, WA 98032 RECEIVED C%TYOFTUKWILA FEB 21 ?007 PR0068168 Lys. REVIEWED FOR CODE COMPLIANCE r FEB 2 8 z001 CORRECTION LTR# PERMITCENiER pis >Z' ltt �� �i)) - // r King County Report No. 3054804 -001 Captive -Aire Systems, Inc. Exhaust hood without exhaust damper Intertek Testing Services NA Inc. General - Photo 1 shows an overall view of the Exhaust hood without exhaust damper for commercial cooking equipment enclosure, which is representative of all models except where indicated. Note: Reference Illustration numbers 1 and 5 for unit dimensions. General Requirements And Definitions Installation: All hoods may be installed in wall or island cooking configurations. These exhaust hoods are intended for use in accordance with the Standard of the National Fire Protection Association for the Installation of E q u i p m e n t f o r the Removal of Smoke a n d Grease -Laden Vapors f r o m Commer is - • x • m u , �• •��. ti NFPA No. 96. CODE COMPLIANCE CONSTRUCTION DETAILS: Exhaust hood without exhaust damper INSULATION: (OPTIONAL) External: Classified Industrial felt manufactured by U.S. Gypsum having a 4 lb /ft density Internal: Insulation, when used in the supply plenums of these hoods, shall be either Classified for Surface Burning Characteristics with a Flame Spread Index of 25 or less or Listed Class 1 air duct. The insulation can be mounted within the supply plenum of the hood where it will not be exposed to cooking vapors. The insulation may be additionally secured to the hood using mechanical fastening. Insulation is to be designated Owens Corning Type 475 FRK or equivalent listed component. Alternate: Type EI-475 SL manufactured by Knauf Fiberglass Alternate: Manville Micro -Aire Type 475 manufactured by Johns Manville Corp Alternate: V612 -FR manufactured by Gaska Tape Inc. CLEARANCE REDUCTION METHODS; The hood may be installed with a 0 inch clearance to combustible materials if constructed in one of the following methods: • 1 inch layer of insulation of type indicated in Insulation Section of this report or approved Kitchen Exhaust Duct Insulation. • 1 inch insulated backsplash • 3 inch un insulated airspace • Back Return (BR) supply plenum These ratings apply to the top, ends, back and front of the exhaust hood. RECEIVED CITYOFTUKWILA FEB 21 2007 PERMITCENTER Issued: 11/03/04 PHOTO NO. 1 rvimrAn FEB 2 8 ZOO/ City Of Tukwila BUILDING DtlITcroni L #RE CTIOIU Mod- - 015 NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2004 Edition CODE C E MPL FOR NCE 9 FEB 28 t�;r: / City Of Tukwila RIJILDTnlj DTI /T ^Tem NFPA, 1 Batterymarch Park, Quincy, MA 02169 -7471 An International Codes and Standards Organization IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA DOCUMENTS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA DOCUMENTS NFPA codes, standards, recommended practices, and guides, of which the document contained herein is one, are developed through a consensus standards development process approved by the American National Standards Institute. This process brings together 'volunteers representing varied viewpoints and interests to achieve consensus on fire and other safety issues. While the NFPA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in its codes and standards. The NFPA disclaims liability for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use o1 or reliance on this document. The NFPA also makes no guaranty or warranty as to the accuracy or completeness of any information published herein. In issuing and making this document available, the NFPA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this doc unent should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. The NFPA has no power, nor does it undertake, to police or enforce compliance with the contents of this document. Nor does the NFPA list, certify, test or inspect products, designs, or installations for compliance with this document. Any certification or other statement of compliance with the requirements of this document shall not be attr to the NFPA and is solely the responsibility of the certifier or maker of the statement. ADDITIONAL NOTICES AND DISCLAIMERS Updating of NFPA Documents Users of NFPA codes, standards, recommended practices, and guides should be aware that these documents may be superseded at any time by the issuance of new editions or may be amended from time to time through the issuance of Tentative Interim Amendments. An official NFPA document at any point in time consists of the current edition of the document together with any Tentative Interim Amendments and any Errata then in effect. In order to determine whether a given document is the current edition and whether it has been amended through the issuance of Tentative Interim Amendments or corrected through the issuance of Errata, consult appropriate NFPA publications such as the National Fire Codese Subscription Service, visit the NFPA website at www.nfpa.org, or contact the NFPA at the address listed below. Interpretations of NFPA Documents CORRECTION � LTR# FEB 212007 ); PERMRCENiER �/ V NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2004 Edition NFPA, 1 Batterymarch Park, Quincy, MA 02169 -7471 An International Codes and Standards Organization IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA DOCUMENTS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA DOCUMENTS NFPA codes, standards, recommended practices, and guides, of which the document contained herein is one are developed through a consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied 'viewpoints and interests to achieve consensus on fire and other safety issues. While the NFPA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in its codes and standards. The NFPA disclaims liability for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on this document. The NFPA also makes no guaranty or warranty as to the accuracy or completeness of any information published herein. In issuing and making this document available, the NFPA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. The NFPA has no power, nor does it undertake, to police or enforce compliance with the contents of this document Nor does the NFPA list, certify, test or inspect products, designs, or installations for compliance with this document. Any certification or other statement of compliance with the requirements of this document shall not be attributable to the NFPA and is solely the responsibility of the certifier or maker of the statement. ADDITIONAL NOTICES AND DISCLAIMERS Updating of NFPA Documents Users of NFPA codes, standards, recommended practices, and guides should be aware that these documents may be superseded at any time by the issuance of new editions or may be amended from time to time through the issuance of Tentative Interim Amendments. An official NFPA document at any point in time consists of the current edition of the document together with any Tentative Interim Amendments and any Errata then in effect. In order to determine whether a given document is the current edition and whether it has been amended through the issuance of Tentative Interim Amendments or corrected through the issuance of Errata, consult appropriate NFPA publications such as the National Fire Codese Subscription Service, visit the NFPA website at www.nfpa.org, or contact the NFPA at the address listed below. Interpretations of NFPA Documents material 4.2.12 Where aclearance reduction system consisting of 0.69 mm (0.02.7.in.) (22 gauge) sheet metal oa 25 mm (1 in.) mineral wool bats or ceramic fiberblanketrenforced with wire mesh or equivalent spaced out 25mm(1 in.) on noncombustible spacers is provided, there shall be aminimuntof 76 mm (3 in.) clearance to combustible material. 4.2.3.3 Zero clearance to limited - combustible materials shall be permitted where protected by metal lath and plaster, ceramic tile, quarry tile, other noncombustible materials or assembly of noncombustible materials, or materials and products that are listed for the purpose of reducing clearance. 4.2.4 Clearance Integrity. 4.2.4.1 In the event of damage, the material or product shall be repaired and restored to meet its intended listing or clearance requirements and shall be acceptable to the authority having jurisdiction 4.2.4.2* In the event of a fire within a kitchen exhaust system, the duct and its enclosure (rated shaft, factory-built grease duct enclosure, or field - applied grease duct enclosure) shall be inspected by qualified personnel to determine whether the duct and protection method are structurally sound, capable of maintaining their fire protection function, and in compliance with this standard for continued operation. 4.2.4.3 Protection shall be provided on the wall from the bottom of the hood to the floor, or to the top of the noncombustible material extending to the floor, to the same level as required in 4.2.1. 4.2.4.4 The protection methods for ducts to reduce clearance shall be applied to the combustible or limited - combustible construction, not to the duct itself 4.3 Field- Applied and Factory-Built Grease Duct Endosures. 4.3.1 Field- applied grease duct enclosures and factory-built grease duct enclosures shall be listed in accordance with UL 2221, Standard far Tests of Fire Resistive Grease Duct Enclosure Assemblies, or equivalent standard and installed in accordance with the manufacturer's instructions and the listing requirements. 4.3.2 Field - applied grease duct enclosures and factory-built grease duct enclosures shall demonstrate that they provide mechanical and structural integrity, resiliency, and stability when subjected to expected building environmental conditions, duct movement under general operating conditions, and duct movement due to fire conditions. 4.3.3 The specifications of material, gauge, and construction of the duct used in the testing and listing of field - applied grease duct enclosures and factory-built grease duct enclosures shall be included as minimum requirements in their listing and installation documentation. 4.14 Clearance Options for Field Applied and Factory Grease Duct Enclosures. The following clearance options for which field - applied grease duct enclosures and factory -built grease duct enclosures have been successfully evaluated shall be clearly identified in their listing and installation documentation and on their label: (1) Open combustible clearance at manufacturer's requested dimensions (2) Closed combustible clearance at manufacturer's requested dimensions, with or without specified ventilation (3) Rated shaft clearance at manufacturer's requested dimensions, with or without specified ventilation 4.4 Building and Structural Duct Contact. 4.4.1 A duct shall be permitted to contact noncombustible 08 -30 -2007 DALE HAWKSWORTH PO BOX 24321 SEATTLE WA 98134 RE: Permit No. M07 -015 14624 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/03/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Ter Marshall, Permit Technician xc: Permit File No. M07 -015 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 February 16, 2007 Dale Hawksworth PO Box 24321 Seattle WA 98168 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M07 -015 Cher's Ono Malasadas —14624 Interurban Bl S Dear Mr. Hawksworth: This letter is to inform you of corrections that must be addressed before your plumbing/gas piping permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throat,* the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely Je fer Pe 'tT encl arshal chnician xc: File No. M07 -015 %.v Cizy of Tukwila P:Uennifer\Correction Letters \2007'M07 -015 Correction Ltr #1.DOC jem Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: February 6, 2007 Project Name: Cher's ONO Malasadas Permit #: M07 -015 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Alien Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide documented approval from King County Health Department for the preparation of food items at this establishment. 2. The plan shows a `one hour rated wall pad on wood wall construction ". The concem is the existing wall and roof framing for the type I hood shall not meet code for clearance to non combustible construction. Please provide a design to show the wall construction shall meet the intent of the code and provide the UL listing of the "one our fire rated wall pad" from the manufacture. (IMC 506.3.6, 507.9 & 304.1) Should there be questions conceming the above requirements, contact the Building Division at 206-431 -3670. No further comments at this time. ACTIVITY NUMBER: M07 -015 DATE: 02 -21 -07 PROJECT NAME: CHER'S ONO MALASADAS SITE ADDRESS: 14624 INTERURBAN VL S Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: (1 2 vision Public Works ❑ DETERMINAT ON OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -22 -07 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 'PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Structural ❑ Permit Coordinator ❑ No further Review Required DATE: Planning Division DUE DATE: 03-22-07 Not Approved (attach comments) E DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 -015 DATE: 01 -31 -07 PROJECT NAME: CHER'S ONO MALASADAS SITE ADDRESS: 14624 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: t Aa 1,1 Budin Division Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete El Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: 041 i ( i Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:'l/' Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY,. PLAN REVIEW /ROUTING SLIP Structural Structural Review Required ❑ No further Review Required Approved with Conditions ❑ Not Approved (attach comments) �►� T 1*l Fire Prevention XI DUE DATE: 02-01 -07 DATE: DUE DATE: 03-01-07 DATE: Planning Division Permit Coordinator Not Applicable n City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 2 / �i / 0 Plan Check/Permit Number: M07-O 15 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Recav CITY OF rutcw F EB 2 1 20071 Project Name: Cher's Ono Malasadas Project Address: 14624 Interuban Bl S Contact Person: Phone Number: Summary of Revisio li L1/ P1/Z P e7/C, / 54/ L! &P./4 jJ A/,J7eue,2 illy 4 i° ,A /7) A/5L16 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: License Information License AFFORHI95 1BS Licensee Name AFFORDABLE HOOD INSTALLTN INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602426086 Ind. Ins. Account Id 7285700 Business Type CORPORATION Address 1 2963 1ST AVE. S. Address 2 City SEATTLE County KING State WA Zip 98134 Phone 2063820160 Status ACTIVE Specialty 1 SHEET METAL Specialty 2 UNUSED Effective Date 1/12/2005 Expiration Date 1/12/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 CBIC SF9353 01/05/2005 Until Cancelled $6,000.00 01/12/2005 Business Owner Information Name Role Effective Date Expiration Date JOHNSTON, ED PRESIDENT 01/10/2005 JOHNSTON, CHAD VICE PRESIDENT 01/12/2005 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= AFFORHI951BS 03/01/2007 I�D MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD CONFIG. WEIGHT TOTAL EX11• CFM RISER(S) TOTAL SUP. CFM RISER(S: END 10 END ROW WIDTH LING - DIA. CFM SP. WIDTH WIG. DIA. CFM S.P. 1 1227 EX-BS-N 3' 0.00'Non. 3' 0.50'OD 600 Deg. 750 9' 8' --- 750 - 0 0 430 SS Where Exposed ALOE N/A LBS. CAPTIVE AIRE EXHAUST FAN DAYTON MOTORIZED SUPPLY DAMPER YODEL CFM SP. I RPM HP. 0 VOLT FLA MODEL CFM SP. 0 VOLT FLA DU50HF'A 750 -0 65I 1090 050 1 115 6.3 3C725 750 .05 7 115 6.3 FAN MODEL ' HT I V B C F R RO WEIGHT LB DU5OHrA 27 1/4 28 7/8 2 21 2I 1/2 13 1/4 17 1/2 55 r • 11001) INFORMATION CAP TntE- -AIRE I1000S ARE B3UIL T IN COMPLIANCE %SITU • NFPA 196 • NSF • B 0.G -0. 193 - • E1L 3054604 -001 #is BUILDING CODES EXHAUST FAN Hood 111 3' 0.00'Non. /3' 0.50'0D— PLAN VIEW - 3' 0.00' LUNG 1227EX -BS -N 4 j V V •00 • 1C.13.0. 4416 • Sfn:CE PSI & ESE NO. 93137 • U L 710 & ULC710 STANDARDS 18' 1 TWO HOUR FIRE RATED DUCT WRAP 18' ELEVATION FRYER I RANGE 11 11 11 J NF A' 1 40' MIN 1 GREASE FILTER E c.51GNO Q rn t cia i° 6) O0 `N r N EXISTING .. ESPRE ' SO B AR rr -. . r r op 1 1 J kIs S1i om PHONE 1 500 1 1 I 1 11 0 .' HANGING HEIGHT: 24' FROM FRONT LOVER EDGE OF HOOD TO COOKING SURFACE 16' HIGH S/S — BAFFLE TYPE EQUIPMENT BY OTHERS ff_zffA THERMAL CERAMICS DUCT INSULATION GREASE DUCT WRAP SHALL BE INSTALLED ONE (1) LAYER AS PER CERTIFIED APPLICATION INSTRUCTIONS - THERMAL CERAMICS SPECIFICATION THIS TWO HOUR APPLICATION SHALL INCLUDE ALL TYPE I EXHAUST DUCTWORK AS SHOWN ON THIS PLAN TO BE ROUTED FROM THE FINISHED CEILING TO A POINT 18' ABOVE THE FINISHED ROOF SURFACE WITHIN A WELDED GALVANIZED EQUIPMENT CURB 16 GAUGE WELDED EXHAUST DUCTWORK FIREMASTER DUCT INSULATION TWO HOUR FIRE RATED DUCT PROTECTION No Scale ONE HOUR FIRE RATED WALL PAD ON WOOD STUD WALL CONSTRUCTION MAX Scale 1/2' = 1' -0' 091 A. m SUM / 11111 FAN FAN INFORMATION DUHFA SERIES UPBLAST EXHAUST FANS AULZ62) HT B 1 R 1 - -- G =R +3 - - - -- - RO c _ GENERAL CONSTRUCTION NOTES ELECTRICAL NOTE MOTORIZED SUPPLY DAMPER 16' X 16' _ 422 FPM VELOCITY AT 750 CFM • 1 / F GREASE DRAIN FEATURE DUN DIRECT DRIVE CENTRIFUGAL UP - BLAST EXHAUST FANS DIMENSIONAL DATA 1. The General Contractor shall provide all structure penetrations for equipment curbs for all exhaust and make -up air systems. 2. The General Contractor shall be responsible for maintaining structural integrity and provide required structural supports as required by the International Building Code and /or as required by the City of Tukwila. 3. The General Contractor shall be responsible for other trades below unless otherwise stated by the conditions of the general contract with the project owner. 1. The electrical contractor shall install exhaust fan and make up air system motor relays and contactors. Check for proper fan rotation. alir iff■S., wEaEe� /1111 1E#1E#1 ■111E#E111 NEEM - IIM111..E1E111111 r. AEI �EfA �E1f - - - ,11E11■ 11E1• - r -- t>_ - ROOF MOUNTED FANS - RESTAURANT MODEL - UL762 - VARIABLE SPEED CONTROL - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTION (SINGLE PHASE) - HIGH HEAT OPERATION 300'r (149'C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY V111LE EXHAUSTING AIR Al 300'F (149t) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS 10 THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE -UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316'C) FOR A PERIOD Or 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. 1 18' - 4 1 3'J CLEAN -OUT ACCESS PANELS AT CHANGE �---- OF DIRECTION i _ 6- 24' I 15' SLOPE EXHAUST DUCTWORK SECTION VIEW j 1 COOKLINE EQUIPMENT EXHAUST FAN 12.00' TWO HOUR FIRE RATED DUCT WRAP -3' Scale 1/2' = 1' -0' • 0 ONE HOUR FIRE RATED WALL PAD ON WOOD STUD WALL CONSTRUCTION 5$7' 44' 4 yo c - yocacao :' o GRASS r ROCKERY 0 0 .0 O 0 � - GRA55 MANAGE AGE ESN+NT. (2 87.4s'5rE I&'4. 1 SITE PLAN SITE PLAN FIRE SUPPRESSION NOTE FLOOR PLAN D S Scate 1' = 20' -0' 1. All Type I hoods and exhaust ductwork systems require R102 - UL 300 wet chemical fire suppression systems. This is to be provided by others under separate permit. MOTORIZED SUPPLY DAMPER EXHAUST FAN EXHAUST HOOD 10' -O' PROPERTY LINE 1 10' -0' MINIMUM TO ANY E AIR INTAKE AND _ PROPERTY LINE Scale 1/4' = 1' -0' OCT 0 3 2007 O Cy Date: EXPIRED 34/07 • VICINITY MAP of ltdcwila BUILDING DIVISION 5 i46ih S! � � -' -J / i " — ' — .01$ Permit 1110. Plan review r -^rowal is subject to eras and omit:sic/a Amara: : (. .:Ct on documents does not authorize the : =;.: code or ordinanc?. Receipt aE a; ;-. :.. - : i z -1 COnCE 9os is acknowledged: I�I 0) . S 150th St _ ^ l' 514 1l81h St • • .. - - .1/ Al 1 1vf E I .- - So4N n . 8 154IhS1 --- — f'...T.-1'-- • 1 t_ � "En - -..(t m (n 11) 1r e-ce j 4 1 PARCEL NO. 0040000901 Not t o Scate SEPARATE PERMIT rw$UIRED FOR O teahan! ® Electrical fi umbIng Piping Cr/ of Tukwila BUIiLDIN3 DIVISION SIZaSuplis Hoch-x:1,m sill . be made to the cce c :L :it ut R,. require a ti wls:ens tri:I r new F:. and may indude additional 1p an review f . LEGAL DESCRIPTION 9 -10 -11 7 ADAMS HLME TRA PORTION OF LOTS 9 & 10 LY ELY OF PACIFIC HIGHWAY SOUTH LESS NORTH 100 FEET LESS SOUTH 30 FEET TGW LOT 11 LESS E 88 FT LESS NORTH 100 FEET LESS SOUTH 30 FEET CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L97 -0037 RECORDING NO 9709220387 PROPERTY OWNER RELIANCE INVESTMENTS, INC. 14620 TUKWILA INTERNATIONAL TUKWILA, WA 98168 (206) 242 -5144 TENANT CHERILYN WILLIAMS 14624 TUKWILA INTERNATIONAL TUKWILA, WA 98168 (206) 271 -1612 BLVD. SO. IECENED Err( sr: - r 1♦. •1 BLVD. SO. AFFORDABLE HOOD INSTALLATIONS, INC. P.O. Box 24321 Seattle. WA 98134 206-999-5163 Contractor Lic. AFFORI1195 1 RS OCCUPANT CHER'S ONO MA LASADA S 14624 International Blvd. So. Tukwila, WA 98168 4' DATE January 29, 2007 CONTRACTOR DALE HAWKSWORTH SHEET 1 of 1 M OP ors 1