Loading...
HomeMy WebLinkAboutPermit M07-038 - ANDERSON RESIDENCEANDERSON RESIDENCE 6289 S 153 ST M07 -038 Parcel No.: Address: Suite No: City of Tukwila Tenant: Name: ANDERSON RESIDENCE Address: 6289 S 153 ST , TUKWILA WA Owner: Name: Address: Contractor: Name: ALL SEASONS INC Address: 5001 N 28 ST , TACOMA WA Contractor License No: ALLSEI *03055 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 6289 S 153 ST TUKW Contact Person: Name: RACHEL PARKOS Address: 4851 S WASHINGTON ST , TACOMA WA MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL NEW ELECTRIC FURNACE/AIR HANDLER AND NEW HEAT PUMP Value of Mechanical: $8,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC - 10/06 EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 879 -9144 Phone: 253 -278 -9344 Expiration Date: 12/17/2007 Steven M. Mullet, Mayor Steve Lancaster, Director M07 -038 02/22/2007 08/21/2007 Fees Collected: $246.53 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 1 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -038 Printed: 02 -22 -2007 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be compile The granting of this permit does construc ' • n or ' - • erfo Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: httn: / /www.ci.tukwila.wa.us V4 of presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc I am authorized to sign and obtain this mechanical permit. RN 0414tiq Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M07 -038 Issue Date: 02/22/2007 Permit Expires On: 08/21/2007 Date: 6 2-12-24a permit and know the same to be true and correct. All provisions of law and ordinances r specified herein or not. Date: 2" 22 o7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 -038 Printed: 02 -22 -2007 Parcel No.: Address: Suite No: Tenant: doc: Cond -10/06 6289 S 153 ST TUKW City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ANDERSON RESIDENCE 1: ** *BUILDING DEPARTMENT COND1TiONS * ** PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** Permit Number: M07 -038 Status: ISSUED Applied Date: 02/20/2007 Issue Date: 02/22/2007 M07 -038 Printed: 02 -22 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: 15. 0_ a K,\„ doc: Cond -10/06 M07 -038 Date: 2-22 -o1 ordinances governing or local laws regulating Printed: 02 -22 -2007 a N' Community Developm: Department �C Permit Center 6300 Southcenter Blvd., Suite 100 19O5 Tukwila, WA 98188 htto: / /www. ct. tuliwila. wa. us Site Address: ( nc ¶ 1 s' - rof Tenant Name: Property Owners Name: Mailing Address: Name: Mailing Address: Company Name: Mailing Address: Contact Person: E-Mail Address: Company Name: Mailing Address: Company Name: Mailing Address: F EB 0 1 2007 Applications and plans must be complete in order to be accepted for plan review. CONIMU N Applications will not be accepted through the mail or by fax. O EVFLOP * *Please Print ** TOW 1 eCwmS t Contractor Regisotion Number: aG& (er Q S� City Contact Person: Day Telephone: E -Mail Address: Fax Number: d:? 1N G lad {. % . .... '.1c: .... .. City Contact Person: Day Telephone: E-Mail Address: Fax Number OMppliaaiawl€Ma6•Applltatime on lanet.34n06 - Mechanical Permit Applicatian.doc Revised: 44006 bh MECHANICAL PERMIT APPLICATION lY1 King Co Assessor's Tax No.: I O S on .. `'1' Suite Number: Floor: New Tenant: ❑ .... Yes ❑ ..No s-r City Day Telephone: Fax Number: Expiration Date: 1 I/ '1 / State State Zip Zip Page 1 of 2 Unit Type: . . Qty Unit pew Qty I)init Type: Qty . Boiler/Compressor: Qty Furnace<100K BTU ( Air Handling Unit >10,000 _ CFM Fire Damper 0 -3 HP /100,000 BTU ' Furnace] 100K BTU Evaporator Cooler iffuser 3-15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent t o ' and Duct Water Heater 50+ HP /1,750,000 Repair or Addition to Heat/Refrig/Cooling .yam Incinerator - Domestic Emergency Generator AirTlandling Unit <10,000 CFM / -- Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ °c Q Scope of Work (pimp provide detailed info i, ation): Use: Residential: New ... Replacement .... ❑ Commercial: New _AD Replacement . -.. ❑ BUILDING O R ? R A :i ZED GE Signature: Print Name: Mailing Address: Date Application Accepted: Q:Mppliuuia Aka - AppliCM O, a On Line13 -7006 - Mcehat:if -0 permit Appliation.doc Rarited: 47006 bh MM pumip Fuel Type: Electric Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED TI'lIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Al Date: 1 10 SUDS 1 }) Day Telephone: S'1 City stun Data Application Expires; 01 1„ v I - Staff Initials: Page 2 of 2 Parcel No.: Address: 6289 S 153 ST TUICW Suite No: Applicant: ANDERSON RESIDENCE Receipt No.: R07 -00249 Payee: ALL SEASONS INC. ACCOUNT ITEM LIST: Description MECHANICAL - RES PLAN CHECK - RES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 02/20/2007 10:14 AM User ID: 1165 Balance: 60.00 TRANSACTION LIST: Type Method Description Amount Payment Check 8729 246.53 Account Code Current Pmts 000/322.100 203.22 000/345.830 43.31 Total: $246.53 Permit Number: M07 -038 Status: APPROVED Applied Date: 02/20/2007 Issue Date: Payment Amount: 6246.53 )3/21 71h , { }f ,. _, doc: Receiot -06 Printed: 02 -20 -2007 Project: ,A-m 3 Type of Inspection: / Mer9.4 F--" Addr At...1 Z0 5 (50 ! Date Called: Special Instructions: Date Wanted: .. 6 `6 m. � Requester: Phone No: 2,7G-2J-7z-7,96 , INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,f /1/107 -c)g PE N (206)431 -3 7 R Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7 e; /7-- Inspector: Date a, $58.0 k rREINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: A V( / / /5ei .v /2Ps - Type of Inspection: r /.✓..9 / — Address: 4 2 P 5 S /> 3 .s- Date Called: Special Instructions: Date Wanted: .2 — 7— 0 7 a.m2 Requester: Phone No: .=.2 -24/0- ?S v INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: /) 61( _2/X-,-3M4.34.5 INSPECTION RECORD Retain a copy with permit FYI (Gt 11—%. C' Date:- 7 "6 703a (206)431 -3 p Approved per applicable codes. Corrections required prior to approval. COMMENTS: pi -to h 7 /d' dGi 2) 4f ''' /s< e t ' � 51 o%t, ( ./ /49 - El $58.0012EINSPECTIOII( FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: !Date: 1. fl. A. B. C. Community Development De ment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 AU' i 1.)0/u Publ, Department: 206. 433 -0179 Planning Division: 206-431-3670 RESIDENTIAL HEATING AND VENTILATION COMPLIANCE FORM (Complete Sections I and II for Group R Occupancies 4 Stories or Less) MECHANICAL PERMIT APPLICATION NO.: jtJl 01-"07M BUILDING PERMIT APPLICATION NO.: WASHINGTON STATE ENERGY CODE f-IEATING DESIGN METHOD (select A, B or C below): ❑ System Anaivsis - W.S.E.C. Ch 4 (submit documentation) ❑ Component eptformanee Approach - W.S.E.C. Chapter 5 (submit documentation) Prescriptive Option -- W.S.E.C. Chapter 6 (fpr,pressriptive, complete the following calculation): House Square Footage (heated space): J 0 X 20 BTUIh ❑ Heating System Installed, (check system type below): 1. 0 Electric Resistance 2. Electric (forced air) 3. ❑ Other Fuels (gas, heat pump) 1. Mini " 4) . 1 0 Maximum BTU of Heating System Output ' WASHINGTON STATE VENTILATION AND INJ)OOR AIR QUALITY CODE (select A or B below): Ventilation by Performance Qr Design Method - W.S.V.1AQ. Section 302 (submit documentation). Prescriptive Ventilation Options - WS.V.I.A.Q. Section 303 (select one of the following): ❑ Ventilation using Exhaust Fans (Section 303.4.1.) ❑ Exception for outdoor air inlets - Forced air heating system wrnterior doors undercut Ys' 2. ❑ Ventilation integrated with Forced Mr System (Section 303.4.2.) 3. ❑ Ventilation using Supply Fan (Section 303.4.3.) 4. ❑ Ventilation using Heat Recovery System (Section 303.4.4.) Prescriptive Minimu . imum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form). RECEIVED 1. House Square Footage: Q� crwOFTUKWILA 2. House Number of Bedrooms. FEB 2 0 2007 3. Required Outdoor Air Table 3 -2: - PERMITCENTER j , j Maximum - cfm 1 ems c l �.'r . / 9' 7 q 4 .�e'.y Te? / 99/ Ve r�rdaw.: max B � ric. i2Z ,,,d vantu thm a . -fan, h.e Cr 40021 C fi €,_ - ! / t e A Kee /d/G'6' / r S' . it o ( 7",1 tiT , S 1 cfm TABLE 3 -2 VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM) ¢yFF 40 13. •For residences that exceed E bedrooms, increase the minimum requirement listed furl bedrooms by an additional 15 CFM per bedroom. The maximum CFM is equal to 1.5 times the minimum. Fan Tested CFM a.25" W.G. 4 inch • ' 70 11111111E1111111111111 .yr^• .�.,,.� f" � � - , , .. �� S _.:4 "X /. Ttir V l �pF< . `^ Y� �" i i 1. '� V? y • � t .....' r ..'.:.. 'r t i .= iii F < Tm' 1 y7' S.f�'^r f�. Z. " "C'_[ ^' eLc, 11W._ :. u�.,...�`�` �pJ:r:.ti [.•.�`:.., !j �_�.�L..S,� .i. .. i... '.::fra+u+. .._�...r. _.�J SO 50 80 . 1 125 Minimum Flex Diameter 4 inch 6 inch 5 inch 5 inch' Maximum Length Feet No Limit Minimum Smooth Diameter 6 Inch 5 inch 5 inch Maximum Length Feet No Limit 100 �': ;1 .1:...cx:s:�s:.: �,,.3..,...`>:. �..�.."..,.: _`�.. sr, •yam! 3 t a L r r•. 1 7 rr C .s „. INIIIIIMINI �FSA'!'` ��1J� .`:� ��./J��l:l.�i.r_.L�.:�. <S�.l. ti:. �.. iF "4 u- l�f? -:: ' :i:� lw. .� 'x V.: h' r S w` j;+kr' 7r1 .. Y-r 7 `S i r sw 6 inch No Limit if i �{S Y 'V • ,�4s)'tr <�F."`•a r ...i xc^,y -+'n �.r�y rc �1��.sy is -v a•... C�+ r <`.fi'jT �� �`Cn � �. p �.t c�r.+� app >y3�� `711II_:t ib] nW.7 SY -Lks� ?: �4LCyi�. 9 . '1ra,:�i Ya FC .:u ^1fsA�vwcr iri 1L1�'J J 1 �'' A:11C?(a r..>w.s A,La' 50 Maximum Elbows' 3 3 1. For each additional elbow subtract 10 feet from length. 2. Flex ducts of this diameter are not permitted with fans of this sire. Etrauiva: 711102 1425crtion hsaUnQ and va eiWien ayatam - form h4 (7,2002) TABLE 3-3 PRESCRIPTIVE EXHAUST DUCT SIZING • ; • ca,oter z4 k-ratt • • if • • • RECEIVED ITY OF TUKWILA FcB 2 Of/007 PEAMITCENTER AAC4 051) Unit Size - Series Indoor Model Cooling Capacity ARI Standard Rat ngs Cooling Heating Furnace Model Factory Enhance Standard Rating SEER TDR EER High Temp Low Temp HSPF E Ca ac- ItY E COP H ac- H COP *FY4ANF018 17,100 TDR &TXV 13.00 10.50 18,000 3.36 10,900 2.24 7.7 FE4ANFOO2 17,700 TDR &TXV 14.50 12.00 17,200 3.64 10,500 2.48 8.2 FF1ENP018 17,100 TDR &TXV 13.00 10.50 18,000 3.38 10,900 2.26 7.7 FF1ENP024 17,400 TDR &TXV 13.20 10.70 17,900 3.44 10,900 2.28 7.7 FV4BNFOO2 17,700 TDR &TXV 14.50 12.00 17,200 3.64 10,500 2.48 8.2 FX4CNF018 17,500 TDR &TXV 14.50 11.70 17,600 3.60 10,500 2.38 8.0 FX4CNF024 17,700 TDR &TXV 15.00 12.00 17,400 3.66 10,500 2.42 8.1 FY4ANF024 17,200 TDR &TXV 13.00 10.50 17,900 3.38 11,000 2.26 7.7 CAP * *1814A ** 17,000 TDR &TXV 14.50 11.70 17,100 3.34 10,200 2.30 7.7 58CV(A,X)070 -12 CAP' 17,000 TXV 13.00 10.50 18,000 3.32 10,900 2.24 7.7 CAP' 17,300 TDR &TXV 14.50 11.70 17,300 3.50 10,300 2.36 7.8 58CV(A,X)070 -12 CAP' 17,400 TXV 13.00 10.80 18,000 3.48 11,000 2.30 7.7 rid//! •.' CAP * *2417A ** 17,400 TDR &TXV 15.00 12.00 17,200 3.54 10,300 2.38 7.8 58CV(A,X)090 -16 CAP * *2417A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.52 10,300 2.36 7.9 58MVB060 -14 CAP * *2417A ** 17,400 13.00 10.80 18,000 3.48 11,000 2.30 7.7 CNPF *2418A ** 17,400 13.00 10.80 18,000 3.54 11,000 2.30 7.8 18 - 30 CNPH*2417A** 17,300 TDR &TXV 14.50 11.70 17,200 3.54 10,300 2.38 7.8 58CV(A,X)070 -12 CNPH *2417A ** 17,400 TDR &TXV 14.50 11.70 17,200 3.58 10,300 2.38 7.9 58CV(A,X)090 -16 CNPH *2417A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.56 10,300 2.38 7.9 58MVB040 -14 CNPH *2417A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.58 10,300 2.38 7.9 58MVB060 -14 CNPH *2417A ** 17,400 TDR &TXV 14.50 11.70 17,300 3.58 10,300 2.38 7.9 58MVB080 -14 CNPH *2417A ** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8 CNPV *1814A ** 17,000 TDR &TXV 14.50 11.70 17,100 3.48 10,300 2.34 7.7 58CV(A,X)070 -12 CNPV *1814A ** 17,000 TXV 13.00 10.80 18,000 3.48 10,900 2.28 7.7 CNPV 2414A 17,300 TDR &TXV 14.50 11.70 17,300 3.54 10,300 2.38 7.8 58CV(A,X)070 -12 CNPV *2414A ** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8 CNPV *2417A ** 17,400 TDR &TXV 14.50 11.70 17,200 3.60 10,300 2.38 7.9 58CV(A,X)090 -16 CNPV *2417A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.56 10,300 2.38 7.9 58MV13060 -14 CNPV *2417A ** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8 CSPH *2412A ** 17,300 TDR &TXV 14.50 11.70 17,200 3.56 10,300 2.38 7.9 58CV(A,X)070 12 CSP11*2412A ** 17,400 TDR &TXV 15.00 12.00 17,200 3.58 10,300 2.38 7.9 58CV(A,X)090 -16 CSPH *2412A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.58 10,300 2.38 7.9 58MVB040 -14 CSPH *2412A ** 17,300 TDR &TXV 15.00 12.00 17,300 3.58 10,300 2.38 7.9 58MVB060 -14 CSPH *2412A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.58 10,400 2.38 7.9 58MVB080 -14 CSPH *2412A ** 17,400 TXV 13.00 10.80 17,800 3.50 11,000 2.32 7.8 *FY4ANF024 22,600 TDR &TXV 13.00 10.5 24,000 3.54 15,000 2.48 8.2 REC6 ` �,�C r EI TXV ^ I FE4ANFOO2 23,200 TDR &TXV 14.50 11.70 23,200 3.78 14,300 2.64 8.5 FE4ANF003 23,400 TDR & 15.00 12.00 23,000 3.76 14,200 2.66 8.5 T i OF T` FFIENP024 22,800 TDR &TXV 13.00 10.70 24,000 3.56 15,200 2.46 8.2 -. - FF1ENP030 22,800 TDR &TXV 13.00 10.40 24,200 3.56 15,100 2.48 8.0 1 V I' j FV4BNFOO2 23,200 TDR &TXV 14.50 11.70 23,200 3.80 14,400 8.5 FV4BNF003 23,400 TDR &TXV 14.50 12.00 23,000 3.78 14,300 8.5 PERMITCCP FX4CNF024 23,000 TDR 8,1XV 14.00 11.40 23,800 3.72 14,600 8.3 FX4CNF030 23,400 TDR &TXV 14.50 11.70 23,800 3.84 14,600 2.66 8.5 FY4ANF030 23,000 TDR &TXV 13.20 10.60 24,000 3.64 15,100 2.52 8.4 �i , ;� i CAP * *2414A ** 22,600 TDR &TXV 14.00 11.50 23,400 3.62 14,300 2.58 8.3 58CV(A,X)070 -12 24 -30 CAP * *2414A ** 22,800 TXV 13.00 10.50 24,400 3.60 15,100 2.50 8.3 rr /rn / J12 /,iiir.,.. !l CAP * *2417A ** 22,800 TDR &TXV 14.50 11.70 23,400 3.66 14,300 2.60 8.4 58CV(A,X)090 -16 CAP * *2417A ** 22,800 TDR &TXV 14.50 11.70 23,400 3.64 14,300 2.58 8.4 58MVB060 -14 CAP * *2417A ** 22,800 TXV 13.00 10.50 24,400 3.60 15,100 2.50 8.3 '/i// / kg CAP * *3014A ** 23,000 TDR &TXV 14.50 11.70 23,000 3.64 14,400 2.60 8.4 58CV(A,X)070 -12 CAP * *3014A ** 23,000 TXV 13.00 10.60 23,400 3.56 15,200 8.3 8.5 CAP * *3017A ** 23,000 TDR &TXV 14.50 11.70 23,000 3.68 14,300 58CV(A,X)090 -16 CAP * *3017A ** 23,000 TDR &TXV 14.50 11.70 23,000 3.68 14,300 2.62 8.5 58MVB060 -14 CAP * *3017A ** 23,000 TXV 13.00 10.60 23,400 3.56 15,200 2.52 8.3 i ;f , ,aHii %/% CNPF *2418A ** 22,800 TXV 13.00 10.50 24,400 3.68 15,200 2.52 8.5 C.) U 2 11, N COMBINATION RATINGS See notes on pg. 1 ED �(1l TER a JtillYrO56 80 70 60 50 30 20 10 0 25HCA BALANCE POINT WORKSHEET 25HCA3 BASED ON AIR AT 70 `0 AND AT RATED -10 0 10 20 30 OUTDOOR TEMPERATURE, BF 40 50 60 70 23.4 20.5 17.6 14.6 11.7 8.8 5.9 2.9 0.0 80 A05007 UNIT SERIES ELECTRICAL CHARACTERISTICS A B C D E F G H J K L M N P 25HCA318 0 X 0 0 0 25 3/4" 31 13/16" 3 3/4" 5/8" 4 7/16" 21 1/4" 9 1/8" 1 1/8" 313/16' 2 13/16' 1/2' 101/4" 10 3/4" 14" 25HCA324 0 X 0 0 0 31 3/16' 2815/16' 33/4' 5/8" 69/16" 2411/16" 91/8" 11/8" 313/16" 2 13/16" 1/2" 155/8" 16 3/4" 141/2" 25HCA330 0 X 0 X 0 31 3/16' 4515/16" 33/4' 3/4' 69/16" 2411/16' 91/8" 1 1/8" 313/16' 2 13/16" 1/2" 201/4" 17 3/8" 18 3/4" 25HCA336 0 X 0 X X 31 3/16" 4515/16" 3 3/4" 3/4" 6 9/16' 24 11/16" 91/8' 1 1/8" 313/18" 2 13/16" 1/2" 17' 14 3/4' 20 3/8' 251-ICA342 0 X 0 X X 35" 391/8" 37/8" 7/8" 69/16" 28 7/16' 91/8" 11/8" 313/16" 215/16' 5 /8' 171/4" 191/8" 153/4' 25HCA348 0 X 0 X X 35' 32 5/18" 3 7/8" 7/8" 6 9/16' 28 7/16" 9 1 /8" 1 1/8" 313/16' 2 15/16" 5 /8" 19" 19' 14 1/2" 25HCA360 0 X 0 X X 35" 391/8" 3 7/8" 7/8" 6 9/16' 28 7/16" 9 1/8" 1 1 /8" 3 13/16" 2 15/16' 5/8" 19" 19' 19" UNIT SIZE MINIMUM MOUNTING PAD DIMENSIONS 18 26" X 26" 24, 30, 36, 42 31 1/2" X 31 1/2" 48, 60 35" X 35" DIMENSIONS B FIELD CONTROL SUPPLY CONN. 01/6' DOLE 3 /U" LIOUID LINE CONN. C FIELD POWER SUPPLY CONN. E8 HID" HOLE WITH 01 1 /S' KNOCKOUT OD VAPOR LINE CORN. 8 1 Aso. X =YES 0 = NO AIR DISCHARGE f I II II 1 11111111 IIIIIilllllll 1111111111 1 1/6' 1. Allow 30" the 13th position of the unit model number. 4. Center of gravity 61 AIR DISCHARGE 03/U" TIEDOWN KNOCKOUTS (2) PLACES 25HCA3 UNIT SIZE V /PH OPER VOLTS* COMPR FAN MCA MIN WIRE SIZEt MIN WIRE SIZEt MAX LENGTH (FT)$ MAX LENGTH (FT)$ MAX FUSE ** or CKT BRK AMPS MAX MIN LRA RLA FLA 60° C 75° C 60° C 75° C 18 -30 208/230/1 253 197 48 9.0 0.75 12 14 14 66 62 20 24 -30 58.3 12.8 0.7 16.7 14 14 47 45 25 30 -30 77 14.1 0.7 21.3 12 12 59 56 30 36 -30 79 16.7 1.2 22 12 12 57 54 35 42 -30 109 19.9 1.2 26 10 10 77 73 40 48 -30 117 21.8 1.2 35.4 8 8 88 84 50 60 -30 134 26.3 1.2 34.1 8 8 91 87 50 30 -50 208/230/3 253 197 71 10.8 0.7 14.2 14 14 64 61 20 36 -50 88 11.3 1.2 15.3 12 12 94 90 25 42 -50 88 13.5 1.2 18.0 10 10 128 122 30 48 -50 83.1 17.2 1.2 22.7 8 10 158 97 35 60 -50 110 17.0 1.2 22.5 8 10 160 98 35 36 -60 460/3 506 414 38 5.6 0.6 7.8 14 14 233 222 15 42 -60 46 7.1 0.5 9.3 14 14 196 186 15 48 -60 41 7.5 0.6 10.0 14 14 182 173 15 60 -60 52 7.8 0.6 10.3 14 14 177 168 15 UNIT SIZE - SERIES REQUIRED SUBCOOLING ( °F) TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) 18 -30 250 10 1000 24 -30 4000 12 30 -30, 50 52.5 11 36 -30, 50, 60 10 42 -30, 50, 60 11 48 -30, 50, 60 11 60- 30,50,60 12 UNIT SIZE STANDARD RATING TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) 125 250 500 1000 2000 4000 8000 18 -30 74 52.5 60.5 68.0 68.5 64.5 60.0 54.0 24 -30 74 54.5 63.0 66.5 66.0 64.0 60.5 51.5 30 -30, 50 74 53.0 60.5 66.0 67.5 64.5 61.5 53.0 36 -30, 50, 60 74 55.0 62.5 67.0 70.5 62.5 60.0 52.5 42 -30, 50, 60 74 55.0 60.0 64.0 67.5 61.5 60.0 55.0 48 -30, 50.60 74 57.5 64.5 67.5 69.5 66.5 61.0 53.0 60 -30, 50, 60 74 53.5 63.0 67.5 70.0 63.5 60.0 55.5 ELECTRICAL DATA A- WEIGHTED SOUND LEVEL (DBA) * Permissible limits of the voltage range at which the unit will operate satafactonly t If wire is applied at ambient greater than 30° C (86° F), consult table 310 -18 of the NEC (ANSI/NFPA 70). The ampacity of non - metallic- sheathed cable (NM), trade name ROMEX, shall be that of 60° C (140° F) conditions, per the NEC (ANSI/NFPA 70) Article 336 -28. If other than uncoated (no- plated), 60 or 75° C (140 or 167° C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). # Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time -Delay fuse. FLA - Full Load Amps LRA - Locked Rotor Amps MCA - Minimum Circuit Amps RLA - Rated Load Amps NOTE: Control circuit is 24 -V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. CHARGING SUBCOOLING (TXV -TYPE EXPANSION DEVICE) 7 Q V N Accessory Description and Usage (Listed Alphabetically) 10. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Carrier thermostats listed in this publication. 11. Outdoor Thermostat An SPDT temperature- actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user - selected set point. Usage Guideline: Electric supplemental heat applications in non - variable speed indoor units when electric heat staging is desired. 12. Secondary Outdoor Thermostat An SPDT temperature- actuated switch which turns on third -stage of supplemental electric heaters when outdoor air temperature drops below the second -stage set point. Usage Guideline: Outdoor thermostat applications where electric heater is capable of 3 -stage operation. - CONTINUED 13. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA. Usage Guideline: Suggested when unit is installed closer than 15 ft. to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft. apart. 14. Thermostatic Expansion Valve (TXV) Bi -Flow A modulating flow - control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Usage Guideline: Accessory required to meet ARI rating and system reliability, where indoor not equipped. Required in all heat pump applications designed with Puron refrigerant. 15. Time -Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: Accessory required to meet ARI rating, where indoor not equipped. ACCESSORY REQUIRED FOR LOW- AMBIENT COOLING APPLICATIONS (Below 55° F) REQUIRED FOR LONG LINE APPUCATIONS* (Over 80 Ft.) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Accumulator Standard Standard Standard Compressor Start Assist Capacitor and Relay Yes Yes No Motor Master Control or Low- ambient Pressure Switch Yes No No Support Feet Recommended No Recommended Liquid Line Solenoid Valve No See Long -Line Ap- plication Guideline No Bali Bearing Fan Motor Vest No No ACCESSORY USAGE GUIDELINE * For tubing line sets between 80 and 200 ft. and /or 20 ft. vertical differential, refer to R esidential Split System Long App Gu� t Required for Low - Ambient Controller (full modulation feature) and MotorMaster® Control only. Accessory Description and Usage (Listed Alphabetically) 1. Ball- Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMaster® is used. 2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single -phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Compressor Start Assist — PTC Type Solid state electrical device which gives a "soft" boost to the compressor at each start-up. Usage Guideline: Suggested in installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 5. Evaporator Freeze Thermostat An SPST temperature- actuated switch that stops unit operation when evaporator reaches freeze -up conditions. Usage Guideline: Required when low ambient kit has been added. 5 6. Isolation Relay An SPDT relay which switches the low - ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. Usage Guideline: Required in all heat pumps where low ambient kit has been added. 7. Liquid -Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. Usage Guideline: An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline. 8. Low- Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low- ambient temperatures down to 0 °F when properly installed. Usage Guideline: A Low- Ambient Pressure Switch or MotorMaster® Low - Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55 ° F (12.8 °C). 9. MotorMaster® Low- Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20 °F (- 28.9 °C), it maintains condensing temperature at 100 ° F ±10 °F (37.8 ° C ± - 12 °C). Usage Guideline: A MotorMaster® Low Ambient Controller or Low- Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55 °F (12.8 °C). Suggested for all commercial applications. M U 2 to N ORDER NUMBER DESCRIPTION 15 -30 24 -30 30 -30 30 -60 36 -30 36 -60 36-60 42 -30 42 -60 42-60 4a -30 4a -60 4a -60 e0 -30 e0 -5o so-em KAACH1201AAA CRANKCASE HTR TSTATXXSBP01 Backplate for Standard Programmable Thermostat TSTATXXBBP01 Backplate for Builder's Thermostat TSTATXXCNV1 Ot Thermostat Conversion Kit (4 to 5 Wire) —10 Pack X X S S S S KAACH1301AAA CRANKCASE HTR X S S KAACH1401AAA CRANKCASE HTR X X X X X X KAACH1501AAA CRANKCASE HTR X KAAFT0101 AAA FREEZE THERMOSTAT X X X X X X X X X X X X X X X X KSAHS1701AAA HARD START (CAP/RELAY) X X X X X X X KHAIR0101AAA ISOLATION RELAY X X X X X X X X X X X X X X X X KSALA0301410 LOW AMBIENT PSW X X X X X X X X X X X X X X X X HC34GE239 MOTOR FAN BALL BEARING X HC34GE242 MOTOR FAN BALL BEARING X X X HC38GE228 MOTOR FAN BALL BEARING X X HC40GE228 MOTOR FAN BALL BEARING X X X X X X KSALA0601AAA MOTORMASTER 230V X X X X X X X X X X X X KSALA0701AAA MOTORMASTER 460V X X X X KHAOT0201SEC THERMOSTAT X X X X X X X X X X X X X X X X KHAOT0301FST TOHERMOSTAT X X X X X X X X X X X X X X X X KHALSO401 LLS SOLENOID VALVE X X X X X X X X X X X X X X X X KAACS0201 PTC START ASSIST PTC X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X X X X X X X X X X KAATD0101TDR TIME DELAY X X X X X X X X X X X X X X X X KSATX0201PUR TXV PURON HSO X X X X KSATX0301PUR TXV PURON HSO X X X X X X KSATX0401PUR TXV PURON HSO X X X KSATX0501PUR TXV PURON HSO X X X THERMOSTAT / SUBBASE PKG. DESCRIPTION TSTATCCPRHO1 -B* Thermidistat" Control — Non - Programmable /Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP and 2S applications. Includes Outdoor Air Temperature Sensor.) . TSTATCCPHHO1 -B* Hybrid Heatr' (Dual Fuel) Thermostat — Auto Changeover, 7 -Day Programmable, °F/ °C, Includes Outdoor Sensor (TSTAT)0XSEN01 -B) TSTATCCPHP01 -B Thermostat — Auto Changeover, 7 -Day Programmable, ¶1°C, 2 -Stage Heat, 1 -Stage Cool TSTATCCNHP01 -C Thermostat — Auto Changeover, Non - Programmable, °F / °C, 2 -Stage Heat, 1 -Stage Cool TSTATCCSHPO1 Standard Programmable Thermostat — Manual Changeover, 5 -2 Day Programmable, °F / °C, 1 -Stage Heat/ 1 -Stage Cool TSTATCCBHP01 -B* Builder's Thermostat — Heat Pump, Non - Programmable, °F/ °C, 2 -Stage Heat, 1 -Stage Cool, Manual Changeover TSTATXXSEN01 -B ** Outdoor Air Temperature Sensor TSTATXXNBP01 Backplate for Non - Programmable Thermostat TSTATXXPBP01 Backplate for Programmable Thermostat and Thermidistat" Control TSTATXXSBP01 Backplate for Standard Programmable Thermostat TSTATXXBBP01 Backplate for Builder's Thermostat TSTATXXCNV1 Ot Thermostat Conversion Kit (4 to 5 Wire) —10 Pack M U to N ACCESSORIES x = Accessory S = Standard sore ACCESSORY THERMOSTATS 4 * Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non - programmable air conditioner version and builder;s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat. t Thermostat conversion kit is a 24 -vac accessory that can turn a 4 -wire thermostat application into a 5 -wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat. PHYSICAL DATA • UNIT SIZE - SERIES 18 -30 24 -30 Operating Weight (Ib) 158 183 Shipping Weight (Ib) 181 210 Compressor Type REFRIGERANT Control Charge (Ib) 5.25 'COND FAN Air Discharge Vertical Air Qty. (CFM) 2196 Motor HP 1/10 Motor RPM 1100 ICOND COIL Face Area (Sq. ft.) 13,13 15.09 Fins per In. 25 20 Rows t 1 Circuits 4 5 VALVE CONNECT. (In. ID) Vapor 5/8 5/8 Liquid REFRIGERANT TUBES* (In. OD) Vapor 5/8 5/8 (0 -80 ft. Tube Length) Liquid (0 -80 ft. Tube Length) ` For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note, See unit Installation Instruction for proper installation. LONG LINE APPLICATION: An application is considered ong line'' when the total equivalent tubing length exceeds S(1 tt_ or when there is more than 20 ft. vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 25(1 ft. The maximum vertical separation is 200 ti. when outdoor unit Acceptable ' Vapor Line Diameters (In. OD) 18000 1/2 1 2 3 5/8 24000 5/8 3/4 5/8 3/4 7/8 5/8 3/4 7/8 42000 ! 3/4 7/8 48000 3/4 7/8 3/4 7/8 1 1/8 Standard I =80 ft or less total equi Unit Nominal Size (Btuh) 1-Stage Puron HP 1--S age Puron HP 30000 1 -Stage Puron HP 36000 1 - - Stage Puron HP 1 Stage Puron HP - -Stage Puron HP 60000 1--Stage Puron HP App cations In t is area may av Long Line Application Guidelines 30 -30, 50 226 258 36 -30, 50, 60 231 263 Scroll Puron (R- -410A) TXV (Puron Hard Shutoff) 5.9 7.6 7.65 Propeller Type, Direct Drive Cooling Standard Application 25 50 80 42 -30, 50, 60 263 295 48 -30, 50, 60 283 313 60 - -30, 50, 60 299 331 8.4 11.75 I 12.35 2614 ', 2614 3365 3810 4046 4046 1/10 1/10 1/5 1/5 1/5 1/5 800 800 800 800 800 800 25.87 25.87 25.15 20.12 22. 63 20 20 20 20 20 1 1 1 2 2 6 6 6 8 8 3/4 3/4 7/8 7/8 7/8 3/8 3/4 VAPOR LINE SIZING AND COOLING CAPACITY LOSS PURON 1 -STAGE HEAT PUMP APPLICATIONS 0 0 0 1 0 0 1 0 0 0 0 0 0 1 0 0 ill I ig t restrictions t at Imtt allowabi ota equtva ent engt , w en out•oor unit iS •e ow rn.opr uni 80 3/8 7/8 ' 7/8 1 -1/8 is above indoor unit, and 80 ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below tor required accessories. See Long -Line Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the Total length to minimize the cooling capacity loss. Capacity Loss ( %)Total Equivalent Line Length (ft.) Long Line Application Requires Accessories 100 125 150 175 200 225 250 ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH 1. Disconnect Kit KFADK0201 DSC Cooling controls and heaters 3- through 10 -kW 2. Downflow Base Kt KFACB0201CFB 002 KFACB0301 CFB 003, 005 KFACB0401CFB 004,006 3. Downflow Conversion Kt KFADCO201SLP 003 KFADC0401ACL 002, 004, 005, 006 4. Single -Point Wiring Kit KFASP0101SPK Only with 15- and 20 -kW Fused Heaters 5. Filter Kit (12 Pack) KFAFK0212MED 002 KFAFK0312LRG 003, 005 KFAFK0412XXL 004,006 6. Filter Media Cabinet FNCCABCC0017 002 FNCCABCC0021 003, 005 FNCCABCC0024 004, 006 7. Media Filter Cartridges FILCCFNC0017 002 FILCCFNC0021 003, 005 FILCCFNC0024 004, 006 8. Infinity'" Air Purifier GAPABXCC1620 002 GAPABXCC2020 003, 005 GAPABXCC2024 004, 006 9. Power Plug Kit (25 Pack) KFAPP0125PLG All 10. PVC Condensate Trap Kit (50 pack) KFAET0150ETK All 11. Air Cleaner 240 -volt Conversion Kit KEAVCO201240 All 12. Downflow/Horizontal Conversion Gasket Kit KFAHD0101SLP All 13. Airflow Sensor Kit (Air Cleaner) KEAAC0101AAA All 14. Horizontal Water Management Kit (25 pack) KFAHC0125AAA All ACCESSORIES * Factory authorized and listed, field Installed. ACCESSORY KITS DESCRIPTION SUGGESTED AND REQUIRED USE 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: Units for 3- through 10 -kW electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1 -in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap -free seal with the floor. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal -left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A- coils. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 4. Single Point Wiring Kit The single point wiring kit acts as a jumper between Ll and L3 lugs, and between the L2 and LA lugs. This allows the installer to run 2 heavy- gauge, high - voltage wires into the fan coil rather than 4 light - gauge, high - voltage wires. SUGGESTED USE: Fan coils with 15- and 20 -kW fused heaters only. 5. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters coiled large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. SUGGESTED USE: To replace filters in fan coils. REQUIRED USE: All units unless a filter grille is used. 6. Filter Media Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using FILCCFNC00(14, 17, 21, 24) media filter cartridges. SUGGESTED USE: All fan coils. 7. Media Filter Cartridges These fan coil media filter cartridge kits are designed for the removal of particles from indoor air. The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE: All fan coils. 8. Infinity" Air Purifier The Infinity Air Purifier wires directly to fan coil and requires no duct transitions with Carrier units. It comes with an airflow sensor. SUGGESTED USE: All fan coils. 9. Power Plug Kit The kit consists of 25 wire harness assemblies. Each plug provides the high - voltage power connection to the fan coil in the absence of electric heat. REQUIRED USE: Units installed without electric heat. 14 CITY RECEIVED FEB 2 0 7007 rient rriNcA1TGd HEATER PART NQ kW PHASE HEATER AMPS 208/230V MIN AMPACITY 200/2300/• MIN WIRE SIZE (AW(S) 208/230/11 MIN owe WIRE SIZE 206/230E MAX FUSE/CICT SKR AMPS 205/2301/ MAX WIRE LENGTH 200/270/ (FT)ft 240V 208V L112 W,L4 15,3.6 L1,L2 W,LA ILLS L1,L2 113.4 16,16 11,12 12,14 15,LA L112 13,8.4 15,16 KFCEH3401F24f••• 24 16.0 1 26.0/32.0 262/32.0 28.0/32.0 44.7/45.5 362/40.0 362/40.0 6/8 8/8 8/8 10/10 45/50 40/40 40/40 50/60 73/73 73/73 KFCEH3501F301••• 30 22.5 1 352/40.0 362/40.0 362/40.0 534/56.5 45.3/50.0 45.3/50.0 5/8 5/6 5/5 10/10 60/60 50/50 50/50 75/50 59/59 5{ ' ACCESSORY ELECTRIC HEATER ELECTRICAL DATA HEATER PARING. O CDN4011103 K5008106011619/ KFCEH0501N015 KECE0R401c00 KFCB12401c05 KFCEt10001NM KICELM101000 KFCEW00INOP•• NECE220o1N000• 10060001E10 10'CEI4So1Ct0 16CBI3o01P10••• 10/'C013101C1P•• NF1 IaCE140013111 KFCE1132o1Fa0.• KECE10301C20••• KPCER3401F24t••• KPCN51501F201••• SW 2400 2000 3 5 B 10 to 15 15 10 16 20 20 24 24 30 30 22 08 56 3A 34 0.0 6.0 m 08 7.5 78 118 118 118 134 155 15.0 10.0 162 228 222 P N A 6 E 3 3 3 3 INTERNAL CIRCUIT PRGIEC- 730N None Nor None CM BR Chl 010 None CM BR Nano N0. Nene CM BR Fun CM We Nene Nunn Fun CM BR Fun Fun Fun Fuse HEATER AMPS 205/230V RN* Chan 102/12.0 181/20.0 121/10.0 151/20.0 181/20.0 30./3x.0 10.552.0 22800.0 10.!/20.8 352/40.0 052/40.0 542/5118 31.3/34.6 37.9/41.5 72.0/708 501/554 057/76.5 02.9/002 1059/120.0 Dual Goma 11,12 13.14 002/40.0 36./40.0 302/40.0 302/40.0 16.1/20.0 151/20.0 229/400 362/400 MinAmpnell7 200/2300/• 152/17.3 20.0/20.4 312/03.5 20.0/.04 212/33.5 447/40.5 44.7/455 40.5/53.5 00.0/246 53.9/568 85/555 76.3/03.4 47.7/514 65880.4 050/106.4 712/778 1159/127.9 08.0/26.0 1448/I050 011311 CNault 11,12 13,14 500508 53.9/68.5 60.0/555 60.4555 22 7/25.0 227/25.0 463/0.0 453/0.0 Min Metes (AWG) 200/200Vtt WORN Wan 12/12 10/10 LA 1010 O/0 9/O 9/0 05 9/O 5/0 8/0 4/4 9/5 5/6 3/2 4/4 1/1 Dun Cheri 13,12 13,14 84 475 4/O 8/6 10/10 101/10 I/O BRANCH CIRCUIT MIn find Wtn Was 206/2300 Goa* 12/12 10/10 1010 10/10 10/10 10/ 10 10/10 10110 10/10 10/10 10/10 0A 10/1 100 aro 008 5ro 8/6 55 Bur Ckeue 11,12 13,14 10/10 10//0 1010 19/1 1010 10110 1010 10 10 Ma Wee/CIO B2r Anpn 200/25V 01.81. Wan 2020 2020 2030 35/35 45150 45/80 50/50 30/35 0000 60100 0180 100/110 80/0/ 125/160 00/100 150170 Gun Wan 11,12 LOA 00100 00.010 69/30 25/25 25/25 5050 5010 878 Maul 07/00 00/80 80/60 05/15 5000 51/00 54/57 70/00 79/00 09/00 59/00 70 65/100 04/06 115/110 87K8 117)130 Ma Win Length SOS/noV ( 11,12 12,13 78100 7000 70/00 Duel Chat 75/78 75/70 550/50 3/3 0100 FIELD MULTIPOINT WIRING OF 24 -AND 30 -kW SINGLE PHASE t Field convertible to 1 phase, single or multiple supply circuit. # Field convertible to 3 phase. •• Includes blower motor amps of largest fan coil used with heater. tt Copper wire must be used. If other than uncoated (non - plated), 75 °C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANSI /NFPA 70). ## Length shown Is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2 %. ••• Heaters are Intelligent Heat' capable when used with the FE, FK and FV fan coils and corporate 2 -speed programmable thermostat (TSTATCCP2S01 -B), Thermidistat" Control (TSTATCCPRH01 -B), or Comfort Zone II'. FE4A / FE5A HEATER PART NO. kW 24�OV VOLTS/ PHASE STAGES (kW OPERATING) INTERNAL INTERNAL PROTECTION FAN COIL SIZE TH HEATING CAR @ 230V# INTEWGENT HEAT CAPABLE (kW OPERATING) KFCEH0501 N05 5 230/1 5 None All 15,700 — KFCEH0901N10 10 230/1 10 None All 31,400 — KFCEH3001F15 15 230/1 5, 15 Fuses ** All 47,100 5, 10, 15 KFCEH3201 F20 20 230/1 5, 20 Fuses ** All 62,800 5, 10, 15, 20 KFCEH2901 N09 9 230/1* 3, 9 None All 28,300 3, 6, 9 KFCEH1601315 15 230/3 5, 15 None All 47,100 — KFCEH3401 F24 24 230/3t 8, 16, 24 Fuses 005, 008 78,500 8, 16, 24 KFCEH3501 F30 30 230/3t 10, 20, 30 Fuses 005, 006 94,200 10, 20, 30 KFCEH2401 CO5 5 230/1 5 Ckt Bkr All 15,700 — KFCEH2601C10 10 230/1 10 Ckt Bkr All 31,400 — KFCEH3101C15 15 230/1 5, 15 Ckt Bkr All 47,100 5, 10, 15 KFCEH3301C20 20 230/1 5, 20 Ckt Bkr All 62,800 5, 10, 15, 20 HEATER kW PHASE FUSES QTY/SIZE CKT BKR QTY/SIZE* 5 1 — 1/60 8 1 — 1 /60 9 1/3 — — 10 1 — 1/60 15 1 2/30, 2/60 2/60 15 3 — — 18 3 — — 20 1 4/60 2/60 24 3/1 6/60 — 30 3/1 6/60 — ACCESSORY ELECTRKS 'EATERS • Field convertible to 3 phase. t These heaters field convertible to single phase. ** Single point wiring kit required for these heaters in Canada. # Blower motor heat not induded. ELECTRIC HEATER INTERNAL PROTECTION • All circuit breakers are 2 pole. 12 MODEL CFM FE4A 400 600 800 1000 1200 1400 1600 1800 2000 002 0.020 0.044 0.048 0.072 0.100 - - - - 003 - 0.020 0.035 0.051 0.070 0.092 - - - 005 - - 0.035 0.051 0.070 0.092 0.120 - - 006 - - - - 0.070 0.092 0.120 0.152 0.187 MODEL CFM FE5A 400 600 800 1000 1200 1400 1600 1800 2000 004 - 0.020 0.035 0.051 0.070 0.092 - - - HEATER KW ELEMENTS STATIC PRESSURE CORRECTION (In. WC.) Sizes 002 -005 Size 006 0 0 +.02 +.03 5 1 +.01 +.02 8, 10 2 0 0 9, 15 3 -.02 -.03 20 4 -.04 -.06 18, 24, 30 6 -.06 -.10 UNIT SIZE VOLTS -PHASE FLA MIN CKT AMPS BRANCH CIRCUIT Min Wire Size Awg* Fuse /Ckt Bkr Amps 002 208/230 -1 4.3 5.4 14 15 003 208/230 -1 4.3 5.4 14 15 005 208/230 -1 4.3 5.4 14 15 004, 006 208/230 -1 8.8 8.5 14 15 MODEL FE4A CFM 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 002 0.012 0.016 0.022 0.028 0.034 0.040 0.049 - - - - 003 - 0.026 0.034 0.042 0.052 0.063 0.075 0.083 0.091 0.098 0.110 005 - 0.006 0.008 0.010 0.012 0.015 0.017 0.020 0.023 0.027 0.030 CFM 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 006 0.013 0.016 0.018 0.020 0.023 0.027 0.030 0.034 0.039 0.044 0.048 MODEL FE5A CFM 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 004 0.004 0.005 0.007 0.009 0.011 0.013 0.018 0.018 0.020 0.023 - NOTE: Subtract the above pressure drop corrections from unit airflow data when that cnmonnent nr condition is used The ramaininn arternal static nressu ire AIRFLOW PERFORMAN CORRECTION FACTORS Th FE4A airflow performance table was developed using fan coils with 10 - kW electric heaters (2 elements) in the units. For fan coils with heaters made up of a different number of elements, the external available static at a given CFM from the table may be corrected by adding or subtracting pressure. Use table for this correction. FACTORY - INSTALLED FILTER STATIC PRESSURE DROP (IN. WC) AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW (DRY TO WET COIL) will be available for the duct system. UNITS WITHOUT ELECTRIC HEAT 11 • U se copper wire only to connect unit. If other than uncoated (non- plated) 75'F ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) Is used consult applicable tables of the National Electric Code (ANSI/NFPA 70). NOTE: If branch circuit wire length exceeds 100 ft, consult NEC 210 - 19a to determine maximum wire length. Use 2% voltage drop. FLA - Full Load Mips BYPASS FACTOR ENTERING AIR DRY -BULB TEMPERATURE ( °F) 79 78 77 76 75 Under 75 81 82 83 84 85 Over 85 Correction Factor 0.10 .098 1.96 2.94 3.92 4.91 Use formula shown below 0.20 0.87 1.74 2.62 3.49 4.36 0.30 0.76 1.53 2.29 3.05 3.82 MODEL SI2E CONDITIONS OCTAVE BAND CENTER FREQUENCY CFM ESP 63 125 250 500 1000 2000 4000 FE4ANFOO2 400 0.25 81.0 57.0 55.0 50.0 48.0 46.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 57.0 56.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 57.8 56.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 FE4ANF003 400 0.25 61.0 57.0 55.0 50.0 48.0 46.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 48.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 59.0 58.0 54.0 52.0 48.0 FE5ANB004 600 0.25 62.7 58.7 58.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 60.4 55.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 61.0 56.0 54.0 52.0 48.0 FE4ANFOO5 400 0.25 61.0 57.0 55.0 50.0 48.0 48.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 59.0 58.0 54.0 52.0 48.0 FE4ANB006 600 0.25 62.7 58.7 58.7 51.7 49.7 47.7 43.7 800 0.25 84.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 025 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 60.4 55.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 61.0 56.0 54.0 52.0 48.0 1800 0.25 67.5 63.5 59.5 58.5 54.5 52.5 48.5 2000 0.25 68.0 64.0 60.0 59.0 55.0 53.0 49.0 2150 025 68.3 64.3 60.3 59.3 55.3 53.3 49.3 CFM - Cubic Ft per Minute - Entering Wet Bulb ( °F) SHC - Gross Sensible Capacity 1000 Btuh BF - Bypass Factor NOTES: 1. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: Leaving db = entering db - sensible heat cao. 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (hiwb) hl,,,,b = hewb -total capacity (Btuh) 4.5 x CFM where hewb = enthalpy of air entering coil. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 80 °F db temperature of air entering coil. Below 80 °F db, subtract (Correction Factor x CFM) from SHC. Above 80 °F db, add (Correction Factor x CFM) to SHC. 4. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. Interpolation is permissible. Correction Factor = 1.09 x (1 - BF) x (db - 80) ESTIMATED SOUND POWER LEVEL (DBA) Handbook, chapter 52, p. 52.7 LWB - Leaving Wet Bulb ( °r TC - Gross Cooling Capacity 1000 Btuh MBH - 1000 Btuh SHC CORRECTION FACTOR * Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications 10 INDOOR COIL AIR SATURATED TEMPERATURE LEAVING EVAPORATOR (°F) 35 40 AS 50 65 CM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF FE4ANF002 500 72 40.19 19.85 0.00 36.23 17.59 0.00 31.88 15.48 0.00 27.00 13.31 0.00 21.85 11.11 0.00 67 32.99 19.92 0.01 28.96 17.79 0.01 24.52 15.62 0.01 19.84 13.40 0.01 14.28 11.17 0.01 62 26.44 20.11 0.01 22.36 17.93 0.01 17.93 15.73 0.01 13.58 13.56 0.03 11.28 11.28 0.19 650 72 49.76 24.23 0.00 44.85 21.76 0.00 39.40 19.20 0.00 33.36 16.55 0.01 26.66 13.83 0.01 67 40.90 24.80 0.01 35.90 22.22 0.01 30.37 19.55 0.02 24.27 16.82 0.02 17.58 14.06 0.02 62 32.84 25.24 0.02 27.75 22.56 0.02 22.25 19.85 0.02 17.13 17.13 0.06 14.25 14.25 0.21 875 72 81.99 30.08 0.00 55.87 27.15 0.00 49.04 24.04 0.01 41.48 20.80 0.02 33.10 17.46 0.02 87 51.08 31.23 0.03 44.83 28.09 0.03 37.91 24.84 0.03 3023 21.47 0.03 21.83 18.03 0.03 62 41.11 32.14 0.03 34.78 28.88 0.03 27.91 25.53 0.04 22.04 22.04 0.10 18.33 18.33 0.25 1000 72 87.83 32.91 0.00 81.10 29.76 0.00 53.86 26.40 0.02 45.36 22.89 0.03 36.17 19.27 0.03 67 55.98 34.39 0.04 49.12 31.01 0.04 41.53 27.48 0.04 33.11 23.83 0.04 23.88 20.06 0.04 62 45.09 35.62 0.04 38.13 32.08 0.04 30.89 28.43 0.05 24.54 24.54 0.12 20.40 20.40 0.27 1250 600 72 77.77 37.84 0.00 70.13 34.30 0.03 61.59 30.55 0.05 52.04 26.60 0.05 41.42 22.50 0.05 67 84.36 40.02 0.06 56.52 3624 0.06 47.77 3227 0.06 38.04 28.12 0.06 27.48 23.81 0.07 62 72 51.98 43.01 41.92 20.98 0.06 0.00 44.00 38.69 37.93 18.78 0.06 FE4ANF003 0.00 35.61 33.92 33.77 16.51 0.06 0.00 29.12 28.64 29.12 14.18 0.16 0.00 24.20 22.85 24.20 11.81 0.30 0.01 87 3527 21.34 0.01 30.88 19.04 0.01 26.07 18.71 0.01 20.79 14.34 0.01 15.03 11.95 0.01 62 28.24 21.59 0.01 23.81 19.25 0.01 19.05 16.90 0.02 14.58 14.56 0.05 12.11 12.11 0.21 800 72 53.83 28.15 0.00 48.40 23.49 0.00 42.36 20.71 0.00 35.72 17.83 0.02 28.38 14.89 0.02 67 44.23 28.92 0.02 38.71 24.10 0.02 32.81 21.20 0.03 25.91 18.24 0.03 18.65 15.28 0.03 82 35.47 27.49 0.03 29.87 24.58 0.03 23.89 21.65 0.03 18.67 18.67 0.09 15.51 15.51 0.24 1000 72 63.07 30.60 0.00 56.66 27.57 0.00 49.58 24.36 0.02 41.76 21.04 0.03 33.10 17.62 0.03 67 51.91 31.82 0.04 45.41 28.58 0.04 38.24 25.24 0.04 30.31 21.78 0.04 21.76 18.29 0.05 82 41.71 32.80 0.04 35.12 29.43 0.04 28.13 28.00 0.05 22.41 22.41 0.12 18.60 18.80 0.27 1200 72 71.01 34.48 0.00 63.77 31.12 0.02 55.79 27.57 0.04 46.95 23.88 0.05 37.18 20.08 0.05 67 58.54 36.17 0.05 5121 32.59 0.05 43.10 28.87 0.06 34.13 25.02 0.06 24.47 21.08 0.06 82 47.12 37.60 0.06 39.70 33.86 0.06 31.89 30.00 0.07 25.83 25.83 0.15 21.43 21.43 0.29 1400 600 72 77.95 37.95 0.01 70.07 34.31 0.04 61.29 30.47 0.06 51.54 28.47 0.06 40.78 22.33 0.07 67 64.44 40.15 0.07 56.37 3628 0.07 47.43 3224 0.07 37.54 28.04 0.07 28.89 23.89 0.08 62 72 51.95 40.42 42.06 19.84 0.07 0.00 43.78 36.59 37.99 17.80 0.06 FESANB004 0.00 35.30 33.73 0.09 28.95 28.95 0.19 24.01 24.01 0.32 32.35 15.70 0.00 27.64 13.54 0.00 22.39 11.33 0.00 67 33.22 20.00 0.00 29.31 17.90 0.00 24.99 15.74 0.00 20.19 13.53 0.00 14.87 11.27 0.00 82 26.67 20.11 0.00 22.69 17.95 0.00 18.31 15.75 0.00 13.60 13.54 0.00 1129 11.29 0.17 800 72 52.07 25.46 0.00 47.19 22.92 0.00 41.75 2028 0.00 35.86 17.53 0.00 28.84 14.70 0.00 87 42.88 25.89 0.00 37.88 23.24 0.00 32.31 20.49 0.00 28.10 17.68 0.00 19.18 14.75 0.00 62 34.51 26.21 0.00 29.39 23.46 0.00 23.73 20.64 0.00 17.81 17.81 0.01 14.85 14.85 0.18 1000 72 82.54 30.48 0.00 56.75 27.53 • 0.00 5025 24.45 0.00 42.94 2121 0.00 34.73 17.84 0.00 67 51.83 3128 0.00 45.68 28.17 0.01 38.98 24.93 0.01 31.49 21.55 0.01 23.12 18.08 0.01 62 41.65 31.91 0.01 35.51 28.66 0.01 28.71 25.30 0.01 21.89 21.89 0.03 1826 18.26 0.19 1200 72 71.89 34.94 0.00 65.33 31.70 0.00 57.89 28.24 0.00 49.50 24.59 0.00 40.06 20.76 0.00 67 59.49 3820 0.01 52.88 32.73 0.01 45.02 29.06 0.01 36.39 25.22 0.01 26.71 2121 0.01 62 48.10 37.22 0.01 41.07 33.55 0.01 33.27 29.72 0.01 25.77 25.77 0.05 21.51 21.51 0.20 1400 750 72 80.24 38.94 0.00 73.00 35.45 0.00 84.73 31.89 0.00 55.41 27.69 0.01 44.86 23.46 0.01 67 86.53 40.71 0.01 58.99 38.93 0.01 50.47 32.91 0.02 40.84 28.86 0.02 29.98 24.20 0.02 g 53.91 5724 42.17 28.01 0.02 0.00 48.10 51.84 38.14 25.08 0.02 FE4ANF005 0.00 37.43 45.46 33.92 22.08 0.02 0.00 29.48 38.59 29.46 19.00 0.07 0.00 24.60 30.99 24.80 15.85 0.22 0.00 67 48.98 28.35 0.00 41.29 25.33 0.00 35.01 2224 0.00 28.09 19.09 0.00 20.47 15.90 0.01 62 37.87 28.59 0.01 31.89 25.50 0.01 25.61 22.37 0.01 19.28 19.28 0.02 16.05 16.05 0.19 950 72 89.88 33.97 0.00 82.89 30.52 0.00 55.32 28.92 0.00 48.89 23.21 0.00 37.57 19.40 0.00 67 57.29 34.68 0.01 50.33 31.06 0.01 42.64 27.33 0.01 34.14 23.51 0.01 24.80 19.83 0.01 82 45.99 3521 0.01 38.92 31.47 0.01 31.24 27.68 0.01 23.90 23.90 0.04 19.89 19.89 0.20 1150 72 80.80 3928 0.00 72.96 35.40 0.00 64.17 31.32 0.00 54.37 27.06 0.01 43.48 22.66 0.01 67 86.56 40.48 0.02 58.50 36.34 0.02 49.54 32.05 0.02 39.80 27.64 0.02 28.70 23.15 0.02 62 53.51 41.36 0.02 45.29 37.07 0.02 36.38 32.70 0.02 28.26 2826 0.07 23.51 23.51 0.22 1500 72 97.47 4729 0.00 88.05 42.83 0.00 77.49 38.05 0.01 65.68 33.04 0.02 52.41 27.78 0.02 87 80.52 49.40 0.03 70.85 44.58 0.03 60.01 39.53 0.03 47.89 34.25 0.03 34.64 28.83 0.04 62 84.96 51.12 0.03 55.02 46.04 0.03 44.30 40.80 0.04 35.27 35.27 0.10 29.34 29.34 0.25 1700 1050 72 105.61 5126 0.00 95.43 46.62 0.01 84.03 41.43 0.03 7121 36.06 0.03 56.82 30.42 0.03 67 87.38 53.92 0.04 76.93 48.80 0.04 85.20 43.40 0.04 52.01 37.70 0.04 37.80 31.83 0.05 62 72 70.60 76.01 58.17 37.07 0.04 0.00 59.87 68.82 50.74 33.39 0.04 FE4ANB006 0.00 48.32 60.76 45.08 29.56 0.05 0.00 38.96 51.72 38.96 25.55 0.13 0.00 32.40 41.64 32.40 21.42 0.27 0.00 67 62.63 37.91 0.01 55.22 34.04 0.01 46.97 30.03 0.01 37.78 25.89 0.01 27.80 21.64 0.01 62 50.40 38.54 0.01 42.81 34.53 0.01 34.49 30.41 0.01 2828 26.28 0.03 21.90 21.90 0.19 1300 72 89.66 43.58 0.00 8126 39.43 0.00 71.77 35.02 0.00 81.13 30.39 0.00 49.17 25.55 0.01 67 74.04 45.04 0.01 65.38 40.80 0.01 55.62 35.94 0.01 44.72 31.09 0.01 32.62 26.09 0.01 62 59.73 46.18 0.01 50.78 41.52 0.02 40.97 36.70 0.02 31.77 31.77 0.06 26.48 26.48 0.21 1750 72 110.09 53.41 0.00 99.92 48.84 0.00 88.41 43.46 0.01 75.38 37.95 0.02 80.66 32.13 0.02 87 9128 56.16 0.02 80.74 50.96 0.03 68.83 45.42 0.03 55.35 39.55 0.03 40.35 33.42 0.03 62 73.94 58.45 0.03 63.04 52.91 0.03 51.06 47.08 0.03 40.82 40.82 0.10 34.04 34.04 0.24 2050 72 121.19 58.89 0.00 110.14 53.79 0.01 97.57 4825 0.02 83.25 42.30 0.03 67.02 35.98 0.03 67 100.75 62.58 0.04 89.24 56.99 0.04 76.15 51.01 0.04 61.30 44.63 0.04 44.72 37.88 0.04 62 81.81 65.71 0.04 69.88 59.72 0.04 56.88 53.37 0.05 46.27 48.27 0.12 38.60 38.60 0.26 2200 72 126.10 61.36 0.00 114.71 58.14 0.02 101.67 50.45 0.03 86.78 44.32 0.03 69.87 37.78 0.04 67 104.99 65.51 0.04 93.05 59.79 0.04 79.44 53.62 0.04 83.97 47.02 0.04 48.71 40.00 0.05 62 85.35 89.12 0.04 72.98 82.94 0.05 59.55 56.35 0.06 48.85 48.85 0.14 40.75 40.75 0.27 GROSS COOLING CAPA'TIES (MBTUH) 9 E4A Algal MODEL AIRFLOW DELIVERY AVAILABLE STATIC PRESSURE FE4ANFOO2 525 CFM 1.00 IN. H2O 700 CFM 1.00 IN. H2O 875 CFM 1.00 IN. H2O 1050 CFM 0.80 IN. H2O 1200 CFM 0.60 IN. H2O FE4AN(B,F)003 700 CFM 1.00 IN. H2O 875 CFM 1.00 IN. H2O 1050 CFM 1.00 IN. H2O 1225 CFM 1.00 IN. H2O 1400 CFM 0.80 IN. H2O FE4AN(B,F)005 875 CFM 1.00 IN. H2O 1050 CFM 1.00 IN. H2O 1225 CFM 1.00 IN. H2O 1400 CFM 1.00 IN. H2O 1600 CFM 0.50 IN. H2O FE4ANB006 1050 CFM 1.00 IN. H2O 1225 CFM 1.00 IN. H2O 1400 CFM 1.00 IN. H2O 1750 CFM 1.00 IN. H2O 2000 CFM 0.60 IN. H2O FE5ANB004 700 CFM 1.00 IN. H2O 875 CFM 1.00 IN. H2O 1050 CFM 1.00 IN. H2O 1225 CFM 1.00 IN. H2O 1400 CFM 1.00 IN. H2O MODEL SYSTEM SIZES CFM RANGE MIN RPM FE4ANFOO2 018, 024, 030, 036 150 — 1200 300 FE4AN(B,F)003 024, 030, 036, 042 200 — 1400 285 FE4AN(B,F)005 030, 036, 042, 048 250 — 1600 275 FE4ANB006 036, 042, 048, 060 500 — 2000 275 FE5ANB004 024, 030, 036, 042 500 — 1400 275 ACCEPTABLE DUCT C6,DITIONS MINIMUM RPM TABLE RETURN STATIC PRESSURE, IN.W.C. For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installed with duct systems which fall within the Acceptable Range' Illustrated above. MAXIMUM STATIC TABLE 8 MODEL FE4A OUTDOOR UNIT CAPACITY BTUH ELECTRIC HEATER kW RANGE 10 15 20 24 30 EMERGENCY 825 675 775 950 — — 18,000 ..._V 675 — — — — 002 24,000 725 775 900 — — — 30,000 875 875 925 1125 — — 36,000 975 975 1025 1125 — — EMERGENCY 675 700 775 850 1050 — — 24,000 675 875 875 1100 1150 — — 003 30,000 800 875 875 1100 1150 — — 36,000 975 975 1025 1150 1250 — — 42,000 1125 1125 1125 1150 1350 — — EMERGENCY 675 700 775 850 1400 1425 30,000 800 875 875 1100 — — 005 36,000 975 975 1025 1150 01 N — — 42,000 1125 1125 1125 1150 — — 48,000 1305 1305 1305 1305 1500 1600 EMERGENCY 1050 1050 1125 1750 1750 36,000 1050 1050 1350 — — 006 42,000 1125 1125 8 1350 — — 48,000 1300 1300 1500 1750 1750 60,000 1625 1625 1750 1750 1750 MODEL FE5A OUTDOOR UNIT CAPACITY BTUH ELECTRIC HEATER kW RANGE 5 9 10 15 20 24 30 EMERGENCY 675 775 775 900 1125 — — 24,000 975 975 975 — — — — 004 30,000 1050 1050 1100 1125 — — — 36,000 1050 1050 1100 1350 1350 — — 42,000 1125 1125 1150 1350 1350 — — PERFORMANCE DATA AIRFLOW DELI' :DOLING, HEATING, ELECTRIC HEATING MODES The FE4 and FE5A fan coils will provide airflow at a rate that is requested by the Integrated System User Interface during air conditioning or heat pump heating (without electric heat) modes. The nominal airflow for both heating and cooling modes is 350 cfm /ton nominal size of the outdoor unit installed. The airflow actually requested by the User Interface is modified by its internal algorithms for zoning, comfort or efficiency concerns. Refer to FE4A/FE5A FAN COIL AIRFLOW DELIVERY CHART 9 - ELECTRIC HEATING MODELS Note 1: Emergency — Air conditioner with electric heater application, or emergency heat Note 2: These airflows are minimum airflows as UL listed. Note 3: Dashed entry indicates that the heater/fan coil /outdoor unit combination is not approved. Do not apply. 7 the documentation for the User Interface for more information on how the User Interface controls the fan coil. Safe operation of electric heaters requires airflow delivery at or above the minimum CFM for electric heater application listed in the chart below. The fan coil will adjust its airflow delivery to maintain safe airflow as operating mode and staging conditions require. LIAM ODS CATALOG ORDERING NO. FIELD- INSTALLED HEAT (KW) NOMINAL COOLING CAPACITY (BTUH) DIMENSIONS (IN) SHIPPING WEIGHT ( Height Width Depth Confi a uration A 18,000 A A A Rows- Fins/In. FE4ANF002000 5, 8, 9, 10, 15, 20 to 42 -11/16 17 -5/8 22 -1/16 135 2,2.5,3,3.5 1. Upflow, Downflow CFM/Ton (Nominal CI• /Hte) 36,000 Motor HP (EC 1/2 1/2 1/2 3/4 3/4 24,000 18 -3/8 18 -7/8 18 -7/8 23 -5/16 FE4AN(B,F)003000 5, 8, 9, 10, 15, 18, 20 to 53 -7/16 21 -1/8 22 -1/16 150 Modular Modular 42,000 30,000 FE4AN(B,F)005000 5, 8, 9, 10, 15, 18, 20, 24, 30 to 53 -7/16 21 -1/8 22 -1/16 172 48,000 36,000 FE4ANB006000 8, 9, 10, 15, 18, 20, 24, 30 to 59 -3/16 24- 11/16 22 -1/16 207 60,000 24,000 FE5ANB004000 5, 8, 9, 10, 15, 18, 20 to 59 -3/16 24- 11/16 22 -1/16 200 42,000 MODEL SIZE COI k 3g ,, '. ;'' , " ,rte, Refri. erant Meterin a Device FE4A FE5A 002 003 005 006 004 N ; "i5 F;' ^-. v. �. ,�, r £ ..., �: . ✓ /f ✓� ;, D j- H /�i -d W 2L //y/ // I _., ..,. Puron® Refit erant (R -410A) TXV TXV Size 2 Ton 3 Ton 4 Ton 4 Ton 3 Ton Confi a uration A Slope A A A Rows- Fins/In. 3 / 14.5 Face Area (Sq Ft) 3.46 3.46 5.93 7.42 "1 , 7.42 Nominal Coolin,Tons 1 .. Air Disch - , e 1.5,2,2.5,3 2,2.5,3,3.5 Upflow, Downflow, 2.5,3,3.5,4 3,3.5,4,5 Horizontal 2,2.5,3,3.5 1. Upflow, Downflow CFM/Ton (Nominal CI• /Hte) 350+ Motor HP (EC 1/2 1/2 1/2 3/4 3/4 Finer 21 -1/2X 18 -3/8 18 -7/8 18 -7/8 23 -5/16 23 -5/16 I + * ' oN: •PT hf `/, ..,,a am , ��.�� .� 1 -piece 1 -piece / Modular 1- piece / Modular Modular Modular PHYSICAL DATA SPECIFICATIONS 6 UNIT SIZE F G COIL CONFIGURATION SHIPPING WEIGHT In. In. SLOPE "A" Lb FE4A 002 18 -9/16 18 -1/4 — Yes 135 003 26 -15/16 27 -1/2 Yes — 150 FE4A 003* 26 -15/16 27 -1/2 Yes — 150 FE4A 005 27 -1/4 26 -15/16 — Yes 172 FE4A 005* 27 -1/4 26 -15/16 — Yes 172 FE4A 006 32 -15/16 32 -5/8 — Yes 207 FE5A 004 32 -15/16 32 -5/8 — Yes 200 DIMENSIONS ROTES: . CONNISATE PAM CRAIN UPS ROT SNNN FOR CLARITY, ITP ItP 7,5 PRINRI NAI SICOMSAIT NAI HORIZ. LEFT D (AS SHIPPED) TTP.• 1 /I' MNIraTAL WWII LOCATIONS . DIIL•LLS R101II0 II TOP PANEL. AND SACS N CASINOS, II CASINO MOUTON. NOM PNTIDID 134• CIA. M0417011TAL MARGIN MAMNAlf TO II FIST, SUPPLIES. NINARY IRA SECONRMY DIAI HORIZ. LEFT (AS SHIPPED) SI if' 70.. PRIMARY ORA SECONDARY DRAT I SII• r i/D• 1 3/111' It PIACISI SCCONNI, IRA PRIMO MAUI f' I". AIRFL01 Ii HACESI. 11/A• S 111• UPFLOI (AS SHIPPED) UPFLOW (AS SHIPPED) t SITS• Ii PLACESI. 3 1 /4• SECORDAIT NAI PMINOT DIAI t 7/1 SIOPF Con PRINAII DRAIN -' A-COI I 11111 ION IS PLACER II PLACEEI. . 1 1311/• DOWNFLOW TIP.. (FIELD CONVERTED) AIRIEST r 3 /If• 1,P L 3/11• PE WEST. F M 314' 3 IIII 1/11• TOP, I4 PLACLSI. DONNFLOI (FIELD CONVERTED) t LIP TIP. f Ii PLACES). I• TIP I It HACISI. 1 13111• rtr. PIINAIY DOA SFCMDAAP DMA STIR• TTP.. SECONMUS 11111 Sn r r TIP.. HORIZ. RIGHT (FIELD CONVERTED) FE4A / FE5A It• I u4• „ .• • I TI • HORIZ. RIGHT Ti (FIELD CONVERTED) TIN 11P,. UNIT SIZE A B C D E H* J* In. In. In. In. In. In. In. FE4A 002 42 -11/16 17 -5/8 15 -3/4 15 -5/8 10 -3/4 — — 003 53 -7/16 21 -1/8 19 -1/4 19 -1/8 19 -3/16 — — FE4A 003* 53 -7/16 21 -1/8 19 -1/4 19 -1/8 19 -3/16 28 -5/16 — FE4A 005 53 -7/16 21 -1/8 19 -1/4 19 -1/8 19 -1/2 — — FE4A 005* 53 -7/16 21 -1/8 19 -1/4 19 -1/8 19 -1/2 28 -5/16 — FE4A 006 59 -3/16 24- 11/16 22 -3/4 22 -11/16 25 -1/4 34 -1/16 — FE5A 004 59 -3/16 24 -11/16 22 -3/4 22 -11/16 25 -1/4 34 -1 /16 — I I /1• DIMENSIONS 15111' 0 SiR' IN 711/• 8 C OPINING Inn IN FRONT VIEW SNOWN 'ITN •A• COIL DETAILS COIMCTIp1 LOCATIONS FOR PROW OR 110112. APPLICATIONS Sle•DIA. 1.0. FOR LOW 0001AGt CONTROL '1110$ IxONNECI CO 0110111 DRYER LOCATION LORI. CONTROL. l ELECTRIC NEATEN ACCESS PANEL OIL ACCESS PANEL 10110 LINE CONNECTION NOTION LIRE CONNECTION I VW FILTER ACCESS PANEL NOTE: I. SERIES DESIGNATION IS TOE IATN PO4111121 OF UNIT PIOWUCT AVNER IN UNIT CONNECTION SIZES SDCTIO: INS l DNS • Oil' I. 0. SWAT 0101111: SI • I.D. I.D.SWATN• I. D. SWAT COIIOERSATE: Sll' FAT SLOPE COIL DETAILS CONNECTION LOCATIONS SAM FOR NATION OR 110012. LEFT APPLICATIONS NOTE: ALLOW 21• FROM FRONT rq SLUICE ntl All ALTERNATE TID•DIA. 0.0. FOR VOLTAGE CONTACT( 11111101 SFKT,S PAWL FONFIG FOE SLOPE COILS 11� IG�ON3 AND "A" COILS DONNFLOW APPLICATIONS FE4A / FE5A -ID SIIL• • — OPTIORAL MELD CONVERTED 110111 SIDE RIOWN OPENING (SLOPE c011 UNITS OWLII TERORE TIN•, 1 3102' Z•DIA. N.O.•S FON NIGH VOLINGE POWER WRING OPPOSITE SIDE I RIGHT SIDE VIEW R tT All -u' t ue• OWtt AIR f 7/1• ,1 1 • i MO TE: NODULAR NNITS WILL NAY( N TWO-PIECE CABINET N H IOW TA MAR UNI1S 2 III' License Information License ALLSEI *03055 Licensee Name ALL SEASONS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601811007 Ind. Ins. Account Id 87655701 Business Type CORPORATION Address 1 5001 N 28TH ST Address 2 City TACOMA County PIERCE State WA Zip 98407 Phone 2532789344 Status ACTIVE Specialty 1 AIR CONDITIONING Specialty 2 AIR HEAT,VENTILATION,EVAPORAT Effective Date 8/25/1997 Expiration Date 12/17/2007 Suspend Date Separation Date Parent Company Previous License ALLSEC *0770M Next License Associated License Business Owner Information Name Role Effective Date Expiration Date AMBUR, KEN PRESIDENT 08/25/1997 Bond Amount BRADSHAW, DAVID VICE PRESIDENT 08/25/1997 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date GREAT AMERICAN INS CO OF Until Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ALLSEI *03055 02/20/2007