HomeMy WebLinkAboutPermit M07-038 - ANDERSON RESIDENCEANDERSON RESIDENCE
6289 S 153 ST
M07 -038
Parcel No.:
Address:
Suite No:
City of Tukwila
Tenant:
Name: ANDERSON RESIDENCE
Address: 6289 S 153 ST , TUKWILA WA
Owner:
Name:
Address:
Contractor:
Name: ALL SEASONS INC
Address: 5001 N 28 ST , TACOMA WA
Contractor License No: ALLSEI *03055
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
6289 S 153 ST TUKW
Contact Person:
Name: RACHEL PARKOS
Address: 4851 S WASHINGTON ST , TACOMA WA
MECHANICAL PERMIT
DESCRIPTION OF WORK:
INSTALL NEW ELECTRIC FURNACE/AIR HANDLER AND NEW HEAT PUMP
Value of Mechanical: $8,000.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
doc: IMC - 10/06
EOUIPMENT TYPE AND OUANTITY
0
0
0
0
0
0
1
0
0
0
0
0
0
0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 253 879 -9144
Phone: 253 -278 -9344
Expiration Date: 12/17/2007
Steven M. Mullet, Mayor
Steve Lancaster, Director
M07 -038
02/22/2007
08/21/2007
Fees Collected: $246.53
International Mechanical Code Edition: 2003
Boiler Compressor:
0-3 HP /100,000 BTU 1
3 -15 HP /500,000 BTU 0
15-30 HP /1,000,000 BTU.. 0
30-50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment 0
M07 -038 Printed: 02 -22 -2007
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be compile
The granting of this permit does
construc ' • n or ' - • erfo
Signature:
Print Name:
doc: IMC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
V4
of presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc
I am authorized to sign and obtain this mechanical permit.
RN
0414tiq
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: M07 -038
Issue Date: 02/22/2007
Permit Expires On: 08/21/2007
Date: 6 2-12-24a
permit and know the same to be true and correct. All provisions of law and ordinances
r specified herein or not.
Date: 2" 22 o7
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende
or abandoned for a period of 180 days from the last inspection.
M07 -038 Printed: 02 -22 -2007
Parcel No.:
Address:
Suite No:
Tenant:
doc: Cond -10/06
6289 S 153 ST TUKW
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
ANDERSON RESIDENCE
1: ** *BUILDING DEPARTMENT COND1TiONS * **
PERMIT CONDITIONS
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: Manufacturers installation instructions shall be available on the job site at the time of inspection.
5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances
shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms,
bathrooms, toilet rooms, storage closets, surgical rooms.
6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE
GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that
the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests.
7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum
distance of 4- inches shall be maintained above the controls with the strapping.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248 - 6630).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
Permit Number: M07 -038
Status: ISSUED
Applied Date: 02/20/2007
Issue Date: 02/22/2007
M07 -038 Printed: 02 -22 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name:
15.
0_ a K,\„
doc: Cond -10/06 M07 -038
Date: 2-22 -o1
ordinances governing
or local laws regulating
Printed: 02 -22 -2007
a N' Community Developm: Department
�C Permit Center
6300 Southcenter Blvd., Suite 100
19O5 Tukwila, WA 98188
htto: / /www. ct. tuliwila. wa. us
Site Address: ( nc ¶ 1 s' - rof
Tenant Name:
Property Owners Name:
Mailing Address:
Name:
Mailing Address:
Company Name:
Mailing Address:
Contact Person:
E-Mail Address:
Company Name:
Mailing Address:
Company Name:
Mailing Address:
F EB 0 1 2007
Applications and plans must be complete in order to be accepted for plan review. CONIMU N
Applications will not be accepted through the mail or by fax. O EVFLOP
* *Please Print **
TOW
1 eCwmS t
Contractor Regisotion Number: aG& (er Q S�
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
d:? 1N G lad {. % . .... '.1c: .... ..
City
Contact Person: Day Telephone:
E-Mail Address: Fax Number
OMppliaaiawl€Ma6•Applltatime on lanet.34n06 - Mechanical Permit Applicatian.doc
Revised: 44006
bh
MECHANICAL PERMIT APPLICATION
lY1
King Co Assessor's Tax No.: I O S on .. `'1'
Suite Number: Floor:
New Tenant: ❑ .... Yes ❑ ..No
s-r
City
Day Telephone:
Fax Number:
Expiration Date: 1 I/ '1 /
State
State
Zip
Zip
Page 1 of 2
Unit Type: .
. Qty
Unit pew
Qty
I)init Type:
Qty
. Boiler/Compressor:
Qty
Furnace<100K BTU
(
Air Handling Unit >10,000 _
CFM
Fire Damper
0 -3 HP /100,000 BTU
'
Furnace] 100K BTU
Evaporator Cooler
iffuser
3-15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30-50 HP /1,750,000 BTU
Appliance Vent
t o ' and Duct
Water Heater
50+ HP /1,750,000
Repair or Addition to
Heat/Refrig/Cooling
.yam
Incinerator - Domestic
Emergency
Generator
AirTlandling Unit
<10,000 CFM
/
-- Comm/Ind
Other Mechanical
Equipment
Valuation of Project (contractor's bid price): $ °c Q
Scope of Work (pimp provide detailed info i, ation):
Use: Residential: New ... Replacement .... ❑
Commercial: New _AD Replacement . -.. ❑
BUILDING O R ? R A :i ZED GE
Signature:
Print Name:
Mailing Address:
Date Application Accepted:
Q:Mppliuuia Aka - AppliCM O, a On Line13 -7006 - Mcehat:if -0 permit Appliation.doc
Rarited: 47006
bh
MM pumip
Fuel Type: Electric Gas ....❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED TI'lIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Al Date: 1 10
SUDS 1 }) Day Telephone: S'1
City stun
Data Application Expires; 01 1„ v I -
Staff Initials:
Page 2 of 2
Parcel No.:
Address: 6289 S 153 ST TUICW
Suite No:
Applicant: ANDERSON RESIDENCE
Receipt No.: R07 -00249
Payee: ALL SEASONS INC.
ACCOUNT ITEM LIST:
Description
MECHANICAL - RES
PLAN CHECK - RES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Initials: JEM Payment Date: 02/20/2007 10:14 AM
User ID: 1165 Balance: 60.00
TRANSACTION LIST:
Type Method Description Amount
Payment Check 8729 246.53
Account Code Current Pmts
000/322.100 203.22
000/345.830 43.31
Total: $246.53
Permit Number: M07 -038
Status: APPROVED
Applied Date: 02/20/2007
Issue Date:
Payment Amount: 6246.53
)3/21 71h , { }f ,. _,
doc: Receiot -06 Printed: 02 -20 -2007
Project:
,A-m 3
Type of Inspection:
/ Mer9.4 F--"
Addr At...1
Z0 5 (50
!
Date Called:
Special Instructions:
Date Wanted:
.. 6 `6 m.
�
Requester:
Phone No:
2,7G-2J-7z-7,96 ,
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
,f
/1/107 -c)g
PE
N
(206)431 -3 7
R Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
7 e; /7--
Inspector:
Date
a, $58.0 k rREINSPECTION EE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
Date:
Project:
A V( / / /5ei .v /2Ps -
Type of Inspection:
r /.✓..9 /
—
Address:
4 2 P 5 S /> 3
.s-
Date Called:
Special Instructions:
Date Wanted:
.2 — 7— 0 7
a.m2
Requester:
Phone No:
.=.2 -24/0- ?S v
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISIO
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Inspector:
/) 61( _2/X-,-3M4.34.5
INSPECTION RECORD
Retain a copy with permit
FYI (Gt 11—%. C'
Date:- 7
"6 703a
(206)431 -3
p Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
pi -to h 7 /d' dGi
2) 4f ''' /s<
e t ' � 51 o%t,
(
./ /49
-
El $58.0012EINSPECTIOII( FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.: !Date:
1.
fl.
A.
B.
C.
Community Development De ment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
AU' i 1.)0/u
Publ, Department:
206. 433 -0179
Planning Division:
206-431-3670
RESIDENTIAL HEATING AND VENTILATION COMPLIANCE FORM
(Complete Sections I and II for Group R Occupancies 4 Stories or Less)
MECHANICAL PERMIT APPLICATION NO.: jtJl 01-"07M
BUILDING PERMIT APPLICATION NO.:
WASHINGTON STATE ENERGY CODE f-IEATING DESIGN METHOD (select A, B or C below):
❑ System Anaivsis - W.S.E.C. Ch 4 (submit documentation)
❑ Component eptformanee Approach - W.S.E.C. Chapter 5 (submit documentation)
Prescriptive Option -- W.S.E.C. Chapter 6 (fpr,pressriptive, complete the following calculation):
House Square Footage (heated space): J 0
X 20 BTUIh
❑ Heating System Installed, (check system type below):
1. 0 Electric Resistance
2. Electric (forced air)
3. ❑ Other Fuels (gas, heat pump)
1.
Mini
" 4) . 1 0 Maximum BTU of Heating System Output
' WASHINGTON STATE VENTILATION AND INJ)OOR AIR QUALITY CODE (select A or B below):
Ventilation by Performance Qr Design Method - W.S.V.1AQ. Section 302 (submit documentation).
Prescriptive Ventilation Options - WS.V.I.A.Q. Section 303 (select one of the following):
❑ Ventilation using Exhaust Fans (Section 303.4.1.)
❑ Exception for outdoor air inlets - Forced air heating system wrnterior doors undercut Ys'
2. ❑ Ventilation integrated with Forced Mr System (Section 303.4.2.)
3. ❑ Ventilation using Supply Fan (Section 303.4.3.)
4. ❑ Ventilation using Heat Recovery System (Section 303.4.4.)
Prescriptive Minimu . imum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form).
RECEIVED
1. House Square Footage: Q� crwOFTUKWILA
2. House Number of Bedrooms. FEB 2 0 2007
3. Required Outdoor Air Table 3 -2: -
PERMITCENTER
j , j Maximum - cfm
1 ems c l �.'r . / 9' 7 q 4 .�e'.y Te? / 99/ Ve
r�rdaw.: max B
� ric. i2Z ,,,d vantu thm a . -fan, h.e Cr 40021 C fi €,_ - ! / t e A Kee /d/G'6' / r S' .
it o ( 7",1 tiT , S 1
cfm
TABLE 3 -2
VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS
Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM)
¢yFF 40 13.
•For residences that exceed E bedrooms, increase the minimum requirement listed furl bedrooms by an additional 15 CFM per
bedroom. The maximum CFM is equal to 1.5 times the minimum.
Fan Tested CFM
a.25" W.G.
4 inch • ' 70 11111111E1111111111111
.yr^• .�.,,.� f" � � - , , .. �� S _.:4 "X /. Ttir V l �pF< . `^ Y� �" i i 1. '� V? y • � t .....' r ..'.:.. 'r t i .= iii F < Tm' 1 y7' S.f�'^r f�. Z.
" "C'_[ ^' eLc, 11W._ :. u�.,...�`�` �pJ:r:.ti [.•.�`:.., !j �_�.�L..S,� .i. .. i... '.::fra+u+. .._�...r. _.�J
SO
50
80
. 1
125
Minimum Flex
Diameter
4 inch
6 inch
5 inch
5 inch'
Maximum Length
Feet
No Limit
Minimum Smooth
Diameter
6 Inch
5 inch
5 inch
Maximum Length
Feet
No Limit
100
�': ;1 .1:...cx:s:�s:.: �,,.3..,...`>:. �..�.."..,.: _`�.. sr, •yam!
3 t a L r r•. 1 7 rr C .s „.
INIIIIIMINI
�FSA'!'` ��1J� .`:� ��./J��l:l.�i.r_.L�.:�. <S�.l. ti:. �.. iF "4 u- l�f? -:: ' :i:� lw. .�
'x V.: h' r S w` j;+kr' 7r1 .. Y-r 7 `S i r sw
6 inch No Limit
if i �{S Y 'V • ,�4s)'tr <�F."`•a r ...i xc^,y -+'n �.r�y rc �1��.sy is -v a•... C�+ r <`.fi'jT �� �`Cn � �. p �.t c�r.+� app >y3��
`711II_:t ib] nW.7 SY -Lks� ?: �4LCyi�. 9 . '1ra,:�i Ya FC .:u ^1fsA�vwcr iri 1L1�'J J 1 �'' A:11C?(a
r..>w.s A,La'
50
Maximum
Elbows'
3
3
1. For each additional elbow subtract 10 feet from length.
2. Flex ducts of this diameter are not permitted with fans of this sire.
Etrauiva: 711102
1425crtion hsaUnQ and va eiWien ayatam - form h4 (7,2002)
TABLE 3-3
PRESCRIPTIVE EXHAUST DUCT SIZING
•
;
•
ca,oter
z4
k-ratt •
• if
•
•
•
RECEIVED
ITY OF TUKWILA
FcB 2 Of/007
PEAMITCENTER
AAC4 051)
Unit Size -
Series
Indoor Model
Cooling
Capacity
ARI Standard Rat ngs
Cooling
Heating
Furnace Model
Factory
Enhance
Standard
Rating
SEER
TDR
EER
High Temp
Low Temp
HSPF
E Ca ac-
ItY
E COP
H ac-
H
COP
*FY4ANF018
17,100
TDR &TXV
13.00
10.50
18,000
3.36
10,900
2.24
7.7
FE4ANFOO2
17,700
TDR &TXV
14.50
12.00
17,200
3.64
10,500
2.48
8.2
FF1ENP018
17,100
TDR &TXV
13.00
10.50
18,000
3.38
10,900
2.26
7.7
FF1ENP024
17,400
TDR &TXV
13.20
10.70
17,900
3.44
10,900
2.28
7.7
FV4BNFOO2
17,700
TDR &TXV
14.50
12.00
17,200
3.64
10,500
2.48
8.2
FX4CNF018
17,500
TDR &TXV
14.50
11.70
17,600
3.60
10,500
2.38
8.0
FX4CNF024
17,700
TDR &TXV
15.00
12.00
17,400
3.66
10,500
2.42
8.1
FY4ANF024
17,200
TDR &TXV
13.00
10.50
17,900
3.38
11,000
2.26
7.7
CAP * *1814A **
17,000
TDR &TXV
14.50
11.70
17,100
3.34
10,200
2.30
7.7
58CV(A,X)070 -12
CAP'
17,000
TXV
13.00
10.50
18,000
3.32
10,900
2.24
7.7
CAP'
17,300
TDR &TXV
14.50
11.70
17,300
3.50
10,300
2.36
7.8
58CV(A,X)070 -12
CAP'
17,400
TXV
13.00
10.80
18,000
3.48
11,000
2.30
7.7
rid//! •.'
CAP * *2417A **
17,400
TDR &TXV
15.00
12.00
17,200
3.54
10,300
2.38
7.8
58CV(A,X)090 -16
CAP * *2417A **
17,300
TDR &TXV
14.50
11.70
17,300
3.52
10,300
2.36
7.9
58MVB060 -14
CAP * *2417A **
17,400
13.00
10.80
18,000
3.48
11,000
2.30
7.7
CNPF *2418A **
17,400
13.00 10.80 18,000
3.54
11,000
2.30
7.8
18 - 30
CNPH*2417A**
17,300
TDR &TXV
14.50
11.70
17,200
3.54
10,300
2.38
7.8
58CV(A,X)070 -12
CNPH *2417A **
17,400
TDR &TXV
14.50
11.70
17,200
3.58
10,300
2.38
7.9
58CV(A,X)090 -16
CNPH *2417A **
17,300
TDR &TXV
14.50
11.70
17,300
3.56
10,300
2.38
7.9
58MVB040 -14
CNPH *2417A **
17,300
TDR &TXV
14.50
11.70
17,300
3.58
10,300
2.38
7.9
58MVB060 -14
CNPH *2417A **
17,400
TDR &TXV
14.50
11.70
17,300
3.58
10,300
2.38
7.9
58MVB080 -14
CNPH *2417A **
17,400
TXV
13.00
10.80
18,000
3.54
11,000
2.30
7.8
CNPV *1814A **
17,000
TDR &TXV
14.50
11.70
17,100
3.48
10,300
2.34
7.7
58CV(A,X)070 -12
CNPV *1814A **
17,000
TXV
13.00
10.80
18,000
3.48
10,900
2.28
7.7
CNPV 2414A
17,300
TDR &TXV
14.50
11.70
17,300
3.54
10,300
2.38
7.8
58CV(A,X)070 -12
CNPV *2414A **
17,400
TXV
13.00
10.80
18,000
3.54
11,000
2.30
7.8
CNPV *2417A **
17,400
TDR &TXV
14.50
11.70
17,200
3.60
10,300
2.38
7.9
58CV(A,X)090 -16
CNPV *2417A **
17,300
TDR &TXV
14.50
11.70
17,300
3.56
10,300
2.38
7.9
58MV13060 -14
CNPV *2417A **
17,400
TXV
13.00
10.80
18,000
3.54
11,000
2.30
7.8
CSPH *2412A **
17,300
TDR &TXV
14.50
11.70
17,200
3.56
10,300
2.38
7.9
58CV(A,X)070 12
CSP11*2412A **
17,400
TDR &TXV
15.00
12.00
17,200
3.58
10,300
2.38
7.9
58CV(A,X)090 -16
CSPH *2412A **
17,300
TDR &TXV
14.50
11.70
17,300
3.58
10,300
2.38
7.9
58MVB040 -14
CSPH *2412A **
17,300
TDR &TXV
15.00
12.00
17,300
3.58
10,300
2.38
7.9
58MVB060 -14
CSPH *2412A **
17,300
TDR &TXV
14.50
11.70
17,300
3.58
10,400
2.38
7.9
58MVB080 -14
CSPH *2412A **
17,400
TXV
13.00
10.80
17,800
3.50
11,000
2.32
7.8
*FY4ANF024
22,600
TDR &TXV
13.00
10.5
24,000
3.54
15,000
2.48
8.2
REC6
` �,�C r
EI TXV
^ I
FE4ANFOO2
23,200
TDR &TXV
14.50
11.70
23,200
3.78
14,300
2.64
8.5
FE4ANF003
23,400
TDR &
15.00
12.00
23,000
3.76
14,200
2.66
8.5
T
i OF T`
FFIENP024
22,800
TDR &TXV
13.00
10.70
24,000
3.56
15,200
2.46
8.2
-. -
FF1ENP030
22,800
TDR &TXV
13.00
10.40
24,200
3.56
15,100
2.48
8.0
1 V
I' j
FV4BNFOO2
23,200
TDR &TXV
14.50
11.70
23,200
3.80
14,400
8.5
FV4BNF003
23,400
TDR &TXV
14.50
12.00
23,000
3.78
14,300
8.5
PERMITCCP
FX4CNF024
23,000
TDR 8,1XV
14.00
11.40
23,800
3.72
14,600
8.3
FX4CNF030
23,400
TDR &TXV
14.50
11.70
23,800
3.84
14,600
2.66
8.5
FY4ANF030
23,000
TDR &TXV
13.20
10.60
24,000
3.64
15,100
2.52
8.4
�i , ;� i
CAP * *2414A **
22,600
TDR &TXV
14.00
11.50
23,400
3.62
14,300
2.58 8.3
58CV(A,X)070 -12
24 -30
CAP * *2414A **
22,800
TXV
13.00
10.50
24,400
3.60
15,100
2.50 8.3
rr /rn /
J12 /,iiir.,.. !l
CAP * *2417A **
22,800
TDR &TXV
14.50
11.70
23,400
3.66
14,300
2.60 8.4
58CV(A,X)090 -16
CAP * *2417A **
22,800
TDR &TXV
14.50
11.70
23,400
3.64
14,300
2.58 8.4
58MVB060 -14
CAP * *2417A **
22,800
TXV
13.00
10.50
24,400
3.60
15,100
2.50 8.3
'/i// / kg
CAP * *3014A **
23,000
TDR &TXV 14.50
11.70
23,000
3.64
14,400
2.60 8.4
58CV(A,X)070 -12
CAP * *3014A **
23,000
TXV
13.00
10.60
23,400
3.56
15,200
8.3
8.5
CAP * *3017A **
23,000
TDR &TXV
14.50
11.70
23,000
3.68
14,300
58CV(A,X)090 -16
CAP * *3017A **
23,000
TDR &TXV
14.50
11.70
23,000
3.68
14,300
2.62 8.5
58MVB060 -14
CAP * *3017A **
23,000
TXV
13.00
10.60
23,400
3.56
15,200
2.52 8.3
i ;f , ,aHii %/%
CNPF *2418A ** 22,800
TXV
13.00 10.50
24,400
3.68
15,200
2.52 8.5
C.)
U
2
11,
N
COMBINATION RATINGS
See notes on pg. 1
ED
�(1l
TER
a JtillYrO56
80
70
60
50
30
20
10
0
25HCA BALANCE POINT WORKSHEET
25HCA3
BASED ON AIR AT 70 `0 AND AT RATED
-10
0
10
20
30
OUTDOOR TEMPERATURE, BF
40
50
60
70
23.4
20.5
17.6
14.6
11.7
8.8
5.9
2.9
0.0
80
A05007
UNIT
SERIES
ELECTRICAL
CHARACTERISTICS
A
B
C
D
E
F
G
H
J
K
L
M
N
P
25HCA318
0
X
0
0
0
25 3/4"
31 13/16"
3 3/4"
5/8"
4 7/16"
21 1/4"
9 1/8"
1 1/8"
313/16'
2 13/16'
1/2'
101/4"
10 3/4"
14"
25HCA324
0
X
0
0
0
31 3/16'
2815/16'
33/4'
5/8"
69/16"
2411/16"
91/8"
11/8"
313/16"
2 13/16"
1/2"
155/8"
16 3/4"
141/2"
25HCA330
0
X
0
X
0
31 3/16'
4515/16"
33/4'
3/4'
69/16"
2411/16'
91/8"
1 1/8"
313/16'
2 13/16"
1/2"
201/4"
17 3/8"
18 3/4"
25HCA336
0
X
0
X
X
31 3/16"
4515/16"
3 3/4"
3/4"
6 9/16'
24 11/16"
91/8'
1 1/8"
313/18"
2 13/16"
1/2"
17'
14 3/4'
20 3/8'
251-ICA342
0
X
0
X
X
35"
391/8"
37/8"
7/8"
69/16"
28 7/16'
91/8"
11/8"
313/16"
215/16'
5 /8'
171/4"
191/8"
153/4'
25HCA348
0
X
0
X
X
35'
32 5/18"
3 7/8"
7/8"
6 9/16'
28 7/16"
9 1 /8"
1 1/8"
313/16'
2 15/16"
5 /8"
19"
19'
14 1/2"
25HCA360
0
X
0
X
X
35"
391/8"
3 7/8"
7/8"
6 9/16'
28 7/16"
9 1/8"
1 1 /8"
3 13/16"
2 15/16'
5/8"
19"
19'
19"
UNIT SIZE
MINIMUM MOUNTING
PAD DIMENSIONS
18
26" X 26"
24,
30, 36,
42
31 1/2" X 31 1/2"
48, 60
35" X 35"
DIMENSIONS
B
FIELD CONTROL
SUPPLY CONN.
01/6' DOLE
3 /U"
LIOUID LINE CONN.
C
FIELD POWER SUPPLY CONN.
E8 HID" HOLE WITH
01 1 /S' KNOCKOUT
OD VAPOR LINE CORN.
8 1
Aso.
X =YES
0 = NO
AIR DISCHARGE
f I
II II 1 11111111
IIIIIilllllll
1111111111
1 1/6'
1. Allow 30"
the 13th position of the unit model number.
4. Center of gravity 61
AIR
DISCHARGE
03/U" TIEDOWN KNOCKOUTS
(2) PLACES
25HCA3
UNIT
SIZE
V /PH
OPER VOLTS*
COMPR
FAN
MCA
MIN
WIRE
SIZEt
MIN
WIRE
SIZEt
MAX
LENGTH
(FT)$
MAX
LENGTH
(FT)$
MAX
FUSE **
or CKT
BRK
AMPS
MAX
MIN
LRA
RLA
FLA
60° C
75° C
60° C
75° C
18 -30
208/230/1
253
197
48
9.0
0.75
12
14
14
66
62
20
24 -30
58.3
12.8
0.7
16.7
14
14
47
45
25
30 -30
77
14.1
0.7
21.3
12
12
59
56
30
36 -30
79
16.7
1.2
22
12
12
57
54
35
42 -30
109
19.9
1.2
26
10
10
77
73
40
48 -30
117
21.8
1.2
35.4
8
8
88
84
50
60 -30
134
26.3
1.2
34.1
8
8
91
87
50
30 -50
208/230/3
253
197
71
10.8
0.7
14.2
14
14
64
61
20
36 -50
88
11.3
1.2
15.3
12
12
94
90
25
42 -50
88
13.5
1.2
18.0
10
10
128
122
30
48 -50
83.1
17.2
1.2
22.7
8
10
158
97
35
60 -50
110
17.0
1.2
22.5
8
10
160
98
35
36 -60
460/3
506
414
38
5.6
0.6
7.8
14
14
233
222
15
42 -60
46
7.1
0.5
9.3
14
14
196
186
15
48 -60
41
7.5
0.6
10.0
14
14
182
173
15
60 -60
52
7.8
0.6
10.3
14
14
177
168
15
UNIT SIZE - SERIES
REQUIRED SUBCOOLING ( °F)
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
18 -30
250
10
1000
24 -30
4000
12
30
-30, 50
52.5
11
36
-30, 50,
60
10
42
-30, 50,
60
11
48
-30, 50,
60
11
60- 30,50,60
12
UNIT SIZE
STANDARD
RATING
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
125
250
500
1000
2000
4000
8000
18 -30
74
52.5
60.5
68.0
68.5
64.5
60.0
54.0
24 -30
74
54.5
63.0
66.5
66.0
64.0
60.5
51.5
30 -30, 50
74
53.0
60.5
66.0
67.5
64.5
61.5
53.0
36 -30, 50, 60
74
55.0
62.5
67.0
70.5
62.5
60.0
52.5
42 -30, 50, 60
74
55.0
60.0
64.0
67.5
61.5
60.0
55.0
48 -30, 50.60
74
57.5
64.5
67.5
69.5
66.5
61.0
53.0
60 -30, 50, 60
74
53.5
63.0
67.5
70.0
63.5
60.0
55.5
ELECTRICAL DATA
A- WEIGHTED SOUND LEVEL (DBA)
* Permissible limits of the voltage range at which the unit will operate satafactonly
t If wire is applied at ambient greater than 30° C (86° F), consult table 310 -18 of the NEC (ANSI/NFPA 70). The ampacity of non - metallic- sheathed cable
(NM), trade name ROMEX, shall be that of 60° C (140° F) conditions, per the NEC (ANSI/NFPA 70) Article 336 -28. If other than uncoated (no- plated), 60
or 75° C (140 or 167° C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables
of the NEC (ANSI/NFPA 70).
# Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time -Delay fuse.
FLA - Full Load Amps
LRA - Locked Rotor Amps
MCA - Minimum Circuit Amps
RLA - Rated Load Amps
NOTE: Control circuit is 24 -V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All
motors/compressors contain internal overload protection.
CHARGING SUBCOOLING (TXV -TYPE EXPANSION DEVICE)
7
Q
V
N
Accessory Description and Usage (Listed Alphabetically)
10. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also is required to enable
special thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Carrier thermostats listed in this
publication.
11. Outdoor Thermostat
An SPDT temperature- actuated switch which turns on
supplemental electric heaters when outdoor air temperature drops
below a user - selected set point.
Usage Guideline:
Electric supplemental heat applications in non - variable
speed indoor units when electric heat staging is desired.
12. Secondary Outdoor Thermostat
An SPDT temperature- actuated switch which turns on
third -stage of supplemental electric heaters when outdoor air
temperature drops below the second -stage set point.
Usage Guideline:
Outdoor thermostat applications where electric heater is
capable of 3 -stage operation.
- CONTINUED
13. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces
the sound level by about 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft. to
quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses less
than 10 ft. apart.
14. Thermostatic Expansion Valve (TXV) Bi -Flow
A modulating flow - control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Usage Guideline:
Accessory required to meet ARI rating and system
reliability, where indoor not equipped.
Required in all heat pump applications designed with
Puron refrigerant.
15. Time -Delay Relay
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
Note: Most indoor unit controls include this feature. For those
that do not, use the guideline below.
Usage Guideline:
Accessory required to meet ARI rating, where indoor
not equipped.
ACCESSORY
REQUIRED FOR LOW- AMBIENT
COOLING APPLICATIONS (Below 55°
F)
REQUIRED FOR
LONG LINE
APPUCATIONS*
(Over 80 Ft.)
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles)
Crankcase Heater
Yes
Yes
No
Evaporator Freeze Thermostat
Yes
No
No
Accumulator
Standard
Standard
Standard
Compressor Start Assist Capacitor and Relay
Yes
Yes
No
Motor Master Control or
Low- ambient Pressure Switch
Yes
No
No
Support Feet
Recommended
No
Recommended
Liquid Line Solenoid Valve
No
See Long -Line Ap-
plication Guideline
No
Bali Bearing Fan Motor
Vest No No
ACCESSORY USAGE GUIDELINE
* For tubing line sets between 80 and 200 ft. and /or 20 ft. vertical differential, refer to R esidential Split System Long App Gu�
t Required for Low - Ambient Controller (full modulation feature) and MotorMaster® Control only.
Accessory Description and Usage (Listed Alphabetically)
1. Ball- Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction
while maintaining bearing lubrication.
Usage Guideline:
Required on all units when MotorMaster® is used.
2. Compressor Start Assist - Capacitor and Relay
Start capacitor and relay gives a "hard" boost to compressor
motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the
following applications:
Long line
Low ambient cooling
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for single -phase scroll compressors in the
following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a "soft" boost to the
compressor at each start-up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles.
Improves compressor lubrication on restart and minimizes the
chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
5. Evaporator Freeze Thermostat
An SPST temperature- actuated switch that stops unit operation
when evaporator reaches freeze -up conditions.
Usage Guideline:
Required when low ambient kit has been added.
5
6. Isolation Relay
An SPDT relay which switches the low - ambient controller out of
the outdoor fan motor circuit when the heat pump switches to
heating mode.
Usage Guideline:
Required in all heat pumps where low ambient kit has
been added.
7. Liquid -Line Solenoid Valve (LLS)
An electrically operated shutoff valve which stops and starts
refrigerant liquid flow in response to compressor operation. It is
to be installed at the outdoor unit to control refrigerant off cycle
migration in the heating mode.
Usage Guideline:
An LLS is required in all long line heat pump
applications to control refrigerant off cycle migration in
the heating mode. See Long Line Guideline.
8. Low- Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit
service valve. It is designed to cycle the outdoor fan motor in
order to maintain head pressure within normal operating limits.
The control will maintain working head pressure at low- ambient
temperatures down to 0 °F when properly installed.
Usage Guideline:
A Low- Ambient Pressure Switch or MotorMaster®
Low - Ambient Controller must be used when cooling operation is
used at outdoor temperatures below 55 ° F (12.8 °C).
9. MotorMaster® Low- Ambient Controller
A fan -speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to the
saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to -20 °F (- 28.9 °C),
it maintains condensing temperature at 100 ° F ±10 °F (37.8 ° C ±
- 12 °C).
Usage Guideline:
A MotorMaster® Low Ambient Controller or
Low- Ambient Pressure Switch must be used when
cooling operation is used at outdoor temperatures
below 55 °F (12.8 °C).
Suggested for all commercial applications.
M
U
2
to
N
ORDER
NUMBER
DESCRIPTION
15 -30
24 -30
30 -30
30 -60
36 -30
36 -60
36-60
42 -30
42 -60
42-60
4a -30
4a -60
4a -60
e0 -30
e0 -5o
so-em
KAACH1201AAA
CRANKCASE HTR
TSTATXXSBP01
Backplate for Standard Programmable Thermostat
TSTATXXBBP01
Backplate for Builder's Thermostat
TSTATXXCNV1 Ot
Thermostat Conversion Kit (4 to 5 Wire) —10 Pack
X
X
S
S
S
S
KAACH1301AAA
CRANKCASE HTR
X
S
S
KAACH1401AAA
CRANKCASE HTR
X
X
X
X
X
X
KAACH1501AAA
CRANKCASE HTR
X
KAAFT0101 AAA
FREEZE THERMOSTAT
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KSAHS1701AAA
HARD START
(CAP/RELAY)
X
X
X
X
X
X
X
KHAIR0101AAA
ISOLATION RELAY
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KSALA0301410
LOW AMBIENT PSW
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
HC34GE239
MOTOR FAN
BALL BEARING
X
HC34GE242
MOTOR FAN
BALL BEARING
X
X
X
HC38GE228
MOTOR FAN
BALL BEARING
X
X
HC40GE228
MOTOR FAN
BALL BEARING
X
X
X
X
X
X
KSALA0601AAA
MOTORMASTER 230V
X
X
X
X
X
X
X
X
X
X
X
X
KSALA0701AAA
MOTORMASTER 460V
X
X
X
X
KHAOT0201SEC
THERMOSTAT
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KHAOT0301FST
TOHERMOSTAT
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KHALSO401 LLS
SOLENOID VALVE
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KAACS0201 PTC
START ASSIST PTC
X
X
X
X
X
X
X
KSASF0101AAA
SUPPORT FEET
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KAATD0101TDR
TIME DELAY
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
KSATX0201PUR
TXV PURON HSO
X
X
X
X
KSATX0301PUR
TXV PURON HSO
X
X
X
X
X
X
KSATX0401PUR
TXV PURON HSO
X
X
X
KSATX0501PUR
TXV PURON HSO
X
X
X
THERMOSTAT / SUBBASE
PKG.
DESCRIPTION
TSTATCCPRHO1 -B*
Thermidistat" Control — Non - Programmable /Programmable Thermostat with Humidity Control (For use in
Dual Fuel, AC, HP and 2S applications. Includes Outdoor Air Temperature Sensor.) .
TSTATCCPHHO1 -B*
Hybrid Heatr' (Dual Fuel) Thermostat — Auto Changeover, 7 -Day Programmable, °F/ °C, Includes Outdoor
Sensor (TSTAT)0XSEN01 -B)
TSTATCCPHP01 -B
Thermostat — Auto Changeover, 7 -Day Programmable, ¶1°C, 2 -Stage Heat, 1 -Stage Cool
TSTATCCNHP01 -C
Thermostat — Auto Changeover, Non - Programmable, °F / °C, 2 -Stage Heat, 1 -Stage Cool
TSTATCCSHPO1
Standard Programmable Thermostat — Manual Changeover, 5 -2 Day Programmable, °F / °C, 1 -Stage Heat/
1 -Stage Cool
TSTATCCBHP01 -B*
Builder's Thermostat — Heat Pump, Non - Programmable, °F/ °C, 2 -Stage Heat, 1 -Stage Cool, Manual
Changeover
TSTATXXSEN01 -B **
Outdoor Air Temperature Sensor
TSTATXXNBP01
Backplate for Non - Programmable Thermostat
TSTATXXPBP01
Backplate for Programmable Thermostat and Thermidistat" Control
TSTATXXSBP01
Backplate for Standard Programmable Thermostat
TSTATXXBBP01
Backplate for Builder's Thermostat
TSTATXXCNV1 Ot
Thermostat Conversion Kit (4 to 5 Wire) —10 Pack
M
U
to
N
ACCESSORIES
x = Accessory S = Standard
sore
ACCESSORY THERMOSTATS
4
* Do not use in zoning heat pump applications.
** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non - programmable air conditioner version and builder;s
thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used
with the dual fuel thermostat.
t Thermostat conversion kit is a 24 -vac accessory that can turn a 4 -wire thermostat application into a 5 -wire application. This kit can also be used to
replace a broken thermostat wire, or add an extra wire when needed.
The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.
PHYSICAL DATA
• UNIT SIZE - SERIES 18 -30 24 -30
Operating Weight (Ib) 158 183
Shipping Weight (Ib) 181 210
Compressor Type
REFRIGERANT
Control
Charge (Ib) 5.25
'COND FAN
Air Discharge Vertical
Air Qty. (CFM) 2196
Motor HP 1/10
Motor RPM 1100
ICOND COIL
Face Area (Sq. ft.) 13,13 15.09
Fins per In. 25 20
Rows t 1
Circuits 4 5
VALVE CONNECT. (In. ID)
Vapor 5/8 5/8
Liquid
REFRIGERANT TUBES* (In. OD)
Vapor 5/8 5/8
(0 -80 ft. Tube Length)
Liquid
(0 -80 ft. Tube Length)
` For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note, See unit Installation Instruction for proper installation.
LONG LINE APPLICATION: An application is considered
ong line'' when the total equivalent tubing length exceeds S(1
tt_ or when there is more than 20 ft. vertical separation between
indoor and outdoor units. These applications require additional
accessories and system modifications for reliable system
operation. The maximum allowable total equivalent length is 25(1
ft. The maximum vertical separation is 200 ti. when outdoor unit
Acceptable
' Vapor Line
Diameters
(In. OD)
18000 1/2 1 2 3
5/8
24000 5/8
3/4
5/8
3/4
7/8
5/8
3/4
7/8
42000 ! 3/4
7/8
48000 3/4
7/8
3/4
7/8
1 1/8
Standard I =80 ft or less total equi
Unit Nominal Size (Btuh)
1-Stage Puron HP
1--S age Puron HP
30000
1 -Stage Puron HP
36000
1 - - Stage Puron HP
1 Stage Puron HP
- -Stage Puron HP
60000
1--Stage Puron HP
App cations In t is area may av
Long Line Application Guidelines
30 -30, 50
226
258
36 -30, 50, 60
231
263
Scroll
Puron (R- -410A)
TXV (Puron Hard Shutoff)
5.9 7.6 7.65
Propeller Type, Direct Drive
Cooling
Standard Application
25 50 80
42 -30, 50, 60
263
295
48 -30, 50, 60
283
313
60 - -30, 50, 60
299
331
8.4 11.75 I 12.35
2614 ', 2614 3365 3810 4046 4046
1/10 1/10 1/5 1/5 1/5 1/5
800 800 800 800 800 800
25.87 25.87 25.15 20.12 22. 63
20 20 20 20 20
1 1 1 2 2
6 6 6 8 8
3/4 3/4 7/8 7/8 7/8
3/8
3/4
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
PURON 1 -STAGE HEAT PUMP APPLICATIONS
0
0
0
1
0
0
1
0
0
0
0
0
0
1
0
0
ill I
ig t restrictions t at Imtt allowabi
ota equtva ent engt , w en out•oor unit iS •e ow rn.opr uni
80
3/8
7/8 ' 7/8 1 -1/8
is above indoor unit, and 80 ft. when the outdoor unit is below
the indoor unit. Refer to Accessory Usage Guideline below tor
required accessories. See Long -Line Application Guideline for
required piping and system modifications. Also, refer to the table
below for the acceptable vapor tube diameters based on the Total
length to minimize the cooling capacity loss.
Capacity Loss ( %)Total Equivalent Line Length (ft.)
Long Line Application Requires Accessories
100 125 150 175 200 225 250
ITEM
ACCESSORY PART NO.*
FAN COIL SIZE USED WITH
1.
Disconnect Kit
KFADK0201 DSC
Cooling controls and heaters 3- through 10 -kW
2.
Downflow Base Kt
KFACB0201CFB
002
KFACB0301 CFB
003, 005
KFACB0401CFB
004,006
3.
Downflow Conversion Kt
KFADCO201SLP
003
KFADC0401ACL
002, 004, 005, 006
4.
Single -Point Wiring Kit
KFASP0101SPK
Only with 15- and 20 -kW Fused Heaters
5.
Filter Kit (12 Pack)
KFAFK0212MED
002
KFAFK0312LRG
003, 005
KFAFK0412XXL
004,006
6.
Filter Media Cabinet
FNCCABCC0017
002
FNCCABCC0021
003, 005
FNCCABCC0024
004, 006
7.
Media Filter Cartridges
FILCCFNC0017
002
FILCCFNC0021
003, 005
FILCCFNC0024
004, 006
8.
Infinity'" Air Purifier
GAPABXCC1620
002
GAPABXCC2020
003, 005
GAPABXCC2024
004, 006
9.
Power Plug Kit (25 Pack)
KFAPP0125PLG
All
10.
PVC Condensate Trap Kit (50 pack)
KFAET0150ETK
All
11.
Air Cleaner 240 -volt Conversion Kit
KEAVCO201240
All
12.
Downflow/Horizontal Conversion Gasket Kit
KFAHD0101SLP
All
13.
Airflow Sensor Kit (Air Cleaner)
KEAAC0101AAA
All
14.
Horizontal Water Management Kit (25 pack)
KFAHC0125AAA
All
ACCESSORIES
* Factory authorized and listed, field Installed.
ACCESSORY KITS DESCRIPTION SUGGESTED AND REQUIRED USE
1. Disconnect Kit
The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely.
SUGGESTED USE: Units for 3- through 10 -kW electric resistance heaters and cooling controls.
2. Downflow Base Kit
This kit is designed to provide a 1 -in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It
also provides a gap -free seal with the floor.
REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications.
3. Downflow Conversion Kit
Fan coils are shipped from the factory for upflow or horizontal -left applications. Downflow conversion kits provide proper condensate
water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A- coils.
REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications.
4. Single Point Wiring Kit
The single point wiring kit acts as a jumper between Ll and L3 lugs, and between the L2 and LA lugs. This allows the installer to run
2 heavy- gauge, high - voltage wires into the fan coil rather than 4 light - gauge, high - voltage wires.
SUGGESTED USE: Fan coils with 15- and 20 -kW fused heaters only.
5. Filter Kit (12 pack)
The kit consists of 12 fan coil framed filters. These filters coiled large dust particles from the return air entering the fan coil and
prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the
efficiency of the system.
SUGGESTED USE: To replace filters in fan coils.
REQUIRED USE: All units unless a filter grille is used.
6. Filter Media Cabinet
This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are
insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using
FILCCFNC00(14, 17, 21, 24) media filter cartridges.
SUGGESTED USE: All fan coils.
7. Media Filter Cartridges
These fan coil media filter cartridge kits are designed for the removal of particles from indoor air. The cartridge is installed in the
return air duct next to the air handler or further upstream.
SUGGESTED USE: All fan coils.
8. Infinity" Air Purifier
The Infinity Air Purifier wires directly to fan coil and requires no duct transitions with Carrier units. It comes with an airflow sensor.
SUGGESTED USE: All fan coils.
9. Power Plug Kit
The kit consists of 25 wire harness assemblies. Each plug provides the high - voltage power connection to the fan coil in the absence of
electric heat.
REQUIRED USE: Units installed without electric heat.
14 CITY RECEIVED
FEB 2 0 7007
rient rriNcA1TGd
HEATER PART NQ
kW
PHASE
HEATER AMPS
208/230V
MIN AMPACITY
200/2300/•
MIN WIRE SIZE (AW(S)
208/230/11
MIN owe
WIRE SIZE
206/230E
MAX FUSE/CICT SKR AMPS
205/2301/
MAX WIRE LENGTH
200/270/ (FT)ft
240V
208V
L112
W,L4
15,3.6
L1,L2
W,LA
ILLS
L1,L2
113.4
16,16
11,12
12,14
15,LA
L112
13,8.4
15,16
KFCEH3401F24f•••
24
16.0
1
26.0/32.0
262/32.0
28.0/32.0
44.7/45.5
362/40.0
362/40.0
6/8
8/8
8/8
10/10
45/50
40/40
40/40
50/60
73/73
73/73
KFCEH3501F301•••
30
22.5
1
352/40.0
362/40.0
362/40.0
534/56.5
45.3/50.0
45.3/50.0
5/8
5/6
5/5
10/10
60/60
50/50
50/50
75/50
59/59
5{ '
ACCESSORY ELECTRIC HEATER ELECTRICAL DATA
HEATER
PARING.
O CDN4011103
K5008106011619/
KFCEH0501N015
KECE0R401c00
KFCB12401c05
KFCEt10001NM
KICELM101000
KFCEW00INOP••
NECE220o1N000•
10060001E10
10'CEI4So1Ct0
16CBI3o01P10•••
10/'C013101C1P••
NF1
IaCE140013111
KFCE1132o1Fa0.•
KECE10301C20•••
KPCER3401F24t•••
KPCN51501F201•••
SW
2400 2000
3
5
B
10
to
15
15
10
16
20
20
24
24
30
30
22
08
56
3A
34
0.0
6.0
m
08
7.5
78
118
118
118
134
155
15.0
10.0
162
228
222
P
N
A
6
E
3
3
3
3
INTERNAL
CIRCUIT
PRGIEC-
730N
None
Nor
None
CM BR
Chl 010
None
CM BR
Nano
N0.
Nene
CM BR
Fun
CM We
Nene
Nunn
Fun
CM BR
Fun
Fun
Fun
Fuse
HEATER AMPS
205/230V
RN*
Chan
102/12.0
181/20.0
121/10.0
151/20.0
181/20.0
30./3x.0
10.552.0
22800.0
10.!/20.8
352/40.0
052/40.0
542/5118
31.3/34.6
37.9/41.5
72.0/708
501/554
057/76.5
02.9/002
1059/120.0
Dual Goma
11,12 13.14
002/40.0
36./40.0
302/40.0
302/40.0
16.1/20.0
151/20.0
229/400
362/400
MinAmpnell7
200/2300/•
152/17.3
20.0/20.4
312/03.5
20.0/.04
212/33.5
447/40.5
44.7/455
40.5/53.5
00.0/246
53.9/568
85/555
76.3/03.4
47.7/514
65880.4
050/106.4
712/778
1159/127.9
08.0/26.0
1448/I050
011311 CNault
11,12 13,14
500508
53.9/68.5
60.0/555
60.4555
22 7/25.0
227/25.0
463/0.0
453/0.0
Min Metes (AWG)
200/200Vtt
WORN
Wan
12/12
10/10
LA
1010
O/0
9/O
9/0
05
9/O
5/0
8/0
4/4
9/5
5/6
3/2
4/4
1/1
Dun Cheri
13,12 13,14
84
475
4/O
8/6
10/10
101/10
I/O
BRANCH CIRCUIT
MIn find Wtn Was
206/2300
Goa*
12/12
10/10
1010
10/10
10/10
10/ 10
10/10
10110
10/10
10/10
10/10
0A
10/1
100
aro
008
5ro
8/6
55
Bur Ckeue
11,12 13,14
10/10
10//0
1010
19/1
1010
10110
1010
10 10
Ma Wee/CIO B2r Anpn
200/25V
01.81.
Wan
2020
2020
2030
35/35
45150
45/80
50/50
30/35
0000
60100
0180
100/110
80/0/
125/160
00/100
150170
Gun Wan
11,12 LOA
00100
00.010
69/30
25/25
25/25
5050
5010
878
Maul
07/00
00/80
80/60
05/15
5000
51/00
54/57
70/00
79/00
09/00
59/00
70
65/100
04/06
115/110
87K8
117)130
Ma Win Length
SOS/noV (
11,12 12,13
78100
7000
70/00
Duel Chat
75/78
75/70
550/50
3/3
0100
FIELD MULTIPOINT WIRING OF 24 -AND 30 -kW SINGLE PHASE
t Field convertible to 1 phase, single or multiple supply circuit.
# Field convertible to 3 phase.
•• Includes blower motor amps of largest fan coil used with heater.
tt Copper wire must be used. If other than uncoated (non - plated), 75 °C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult
applicable tables of the National Electric Code (ANSI /NFPA 70).
## Length shown Is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2 %.
••• Heaters are Intelligent Heat' capable when used with the FE, FK and FV fan coils and corporate 2 -speed programmable thermostat (TSTATCCP2S01 -B), Thermidistat" Control
(TSTATCCPRH01 -B), or Comfort Zone II'.
FE4A / FE5A
HEATER
PART NO.
kW
24�OV
VOLTS/
PHASE
STAGES (kW
OPERATING)
INTERNAL
INTERNAL
PROTECTION
FAN COIL
SIZE
TH
HEATING CAR
@ 230V#
INTEWGENT
HEAT CAPABLE
(kW OPERATING)
KFCEH0501 N05
5
230/1
5
None
All
15,700
—
KFCEH0901N10
10
230/1
10
None
All
31,400
—
KFCEH3001F15
15
230/1
5, 15
Fuses **
All
47,100
5, 10, 15
KFCEH3201 F20
20
230/1
5, 20
Fuses **
All
62,800
5, 10, 15, 20
KFCEH2901 N09
9
230/1*
3, 9
None
All
28,300
3, 6, 9
KFCEH1601315
15
230/3
5, 15
None
All
47,100
—
KFCEH3401 F24
24
230/3t
8, 16, 24
Fuses
005, 008
78,500
8, 16, 24
KFCEH3501 F30
30
230/3t
10, 20, 30
Fuses
005, 006
94,200
10, 20, 30
KFCEH2401 CO5
5
230/1
5
Ckt Bkr
All
15,700
—
KFCEH2601C10
10
230/1
10
Ckt Bkr
All
31,400
—
KFCEH3101C15
15
230/1
5, 15
Ckt Bkr
All
47,100
5, 10, 15
KFCEH3301C20
20
230/1
5, 20
Ckt Bkr
All
62,800
5, 10, 15, 20
HEATER kW
PHASE
FUSES QTY/SIZE
CKT BKR QTY/SIZE*
5
1
—
1/60
8
1
—
1 /60
9
1/3
—
—
10
1
—
1/60
15
1
2/30, 2/60
2/60
15
3
—
—
18
3
—
—
20
1
4/60
2/60
24
3/1
6/60
—
30
3/1
6/60
—
ACCESSORY ELECTRKS 'EATERS
• Field convertible to 3 phase.
t These heaters field convertible to single phase.
** Single point wiring kit required for these heaters in Canada.
# Blower motor heat not induded.
ELECTRIC HEATER INTERNAL PROTECTION
• All circuit breakers are 2 pole.
12
MODEL
CFM
FE4A
400
600
800
1000
1200
1400
1600
1800
2000
002
0.020
0.044
0.048
0.072
0.100
-
-
-
-
003
-
0.020
0.035
0.051
0.070
0.092
-
-
-
005
-
-
0.035
0.051
0.070
0.092
0.120
-
-
006
-
-
-
-
0.070
0.092
0.120
0.152
0.187
MODEL
CFM
FE5A
400
600
800
1000
1200
1400
1600
1800
2000
004
-
0.020
0.035
0.051
0.070
0.092
-
-
-
HEATER KW
ELEMENTS
STATIC PRESSURE CORRECTION (In. WC.)
Sizes 002 -005
Size 006
0
0
+.02
+.03
5
1
+.01
+.02
8, 10
2
0
0
9, 15
3
-.02
-.03
20
4
-.04
-.06
18, 24, 30
6
-.06
-.10
UNIT SIZE
VOLTS -PHASE
FLA
MIN CKT AMPS
BRANCH CIRCUIT
Min Wire Size Awg*
Fuse /Ckt Bkr Amps
002
208/230 -1
4.3
5.4
14
15
003
208/230 -1
4.3
5.4
14
15
005
208/230 -1
4.3
5.4
14
15
004, 006
208/230 -1
8.8
8.5
14
15
MODEL
FE4A
CFM
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
002
0.012
0.016
0.022
0.028
0.034
0.040
0.049
-
-
-
-
003
-
0.026
0.034
0.042
0.052
0.063
0.075
0.083
0.091
0.098
0.110
005
-
0.006
0.008
0.010
0.012
0.015
0.017
0.020
0.023
0.027
0.030
CFM
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
006
0.013
0.016
0.018
0.020
0.023
0.027
0.030
0.034
0.039
0.044
0.048
MODEL
FE5A
CFM
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
004
0.004
0.005
0.007
0.009
0.011
0.013
0.018
0.018
0.020
0.023
-
NOTE: Subtract the above pressure drop corrections from unit airflow data when that cnmonnent nr condition is used The ramaininn arternal static nressu ire
AIRFLOW PERFORMAN CORRECTION FACTORS
Th FE4A airflow performance table was developed using fan coils with 10 - kW electric heaters (2 elements) in the units. For fan coils with heaters made
up of a different number of elements, the external available static at a given CFM from the table may be corrected by adding or subtracting pressure. Use
table for this correction.
FACTORY - INSTALLED FILTER STATIC PRESSURE DROP (IN. WC)
AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN.
WC) AT INDICATED AIRFLOW (DRY TO WET COIL)
will be available for the duct system.
UNITS WITHOUT ELECTRIC HEAT
11
• U se copper wire only to connect unit. If other than uncoated (non- plated) 75'F ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for
larger than 10 AWG) Is used consult applicable tables of the National Electric Code (ANSI/NFPA 70).
NOTE: If branch circuit wire length exceeds 100 ft, consult NEC 210 - 19a to determine maximum wire length. Use 2% voltage drop.
FLA - Full Load Mips
BYPASS
FACTOR
ENTERING AIR DRY -BULB TEMPERATURE ( °F)
79
78
77
76
75
Under 75
81
82
83
84
85
Over 85
Correction Factor
0.10
.098
1.96
2.94
3.92
4.91
Use
formula
shown
below
0.20
0.87
1.74
2.62
3.49
4.36
0.30
0.76
1.53
2.29
3.05
3.82
MODEL
SI2E
CONDITIONS
OCTAVE BAND CENTER FREQUENCY
CFM
ESP
63
125
250
500
1000
2000
4000
FE4ANFOO2
400
0.25
81.0
57.0
55.0
50.0
48.0
46.0
42.0
600
0.25
62.7
58.7
56.7
51.7
49.7
47.7
43.7
800
0.25
64.0
60.0
58.0
53.0
51.0
49.0
45.0
1000
0.25
65.0
61.0
57.0
56.0
52.0
50.0
46.0
1200
0.25
65.8
61.8
57.8
56.8
52.8
50.8
46.8
1400
0.25
66.4
62.4
58.4
57.4
53.4
51.4
47.4
FE4ANF003
400
0.25
61.0
57.0
55.0
50.0
48.0
46.0
42.0
600
0.25
62.7
58.7
56.7
51.7
49.7
47.7
43.7
800
0.25
64.0
60.0
58.0
53.0
51.0
49.0
45.0
1000
0.25
65.0
61.0
59.0
54.0
52.0
50.0
48.0
1200
0.25
65.8
61.8
59.8
54.8
52.8
50.8
46.8
1400
0.25
66.4
62.4
58.4
57.4
53.4
51.4
47.4
1600
0.25
67.0
63.0
59.0
58.0
54.0
52.0
48.0
FE5ANB004
600
0.25
62.7
58.7
58.7
51.7
49.7
47.7
43.7
800
0.25
64.0
60.0
58.0
53.0
51.0
49.0
45.0
1000
0.25
65.0
61.0
59.0
54.0
52.0
50.0
46.0
1200
0.25
65.8
61.8
59.8
54.8
52.8
50.8
46.8
1400
0.25
66.4
62.4
60.4
55.4
53.4
51.4
47.4
1600
0.25
67.0
63.0
61.0
56.0
54.0
52.0
48.0
FE4ANFOO5
400
0.25
61.0
57.0
55.0
50.0
48.0
48.0
42.0
600
0.25
62.7
58.7
56.7
51.7
49.7
47.7
43.7
800
0.25
64.0
60.0
58.0
53.0
51.0
49.0
45.0
1000
0.25
65.0
61.0
59.0
54.0
52.0
50.0
46.0
1200
0.25
65.8
61.8
59.8
54.8
52.8
50.8
46.8
1400
0.25
66.4
62.4
58.4
57.4
53.4
51.4
47.4
1600
0.25
67.0
63.0
59.0
58.0
54.0
52.0
48.0
FE4ANB006
600
0.25
62.7
58.7
58.7
51.7
49.7
47.7
43.7
800
0.25
84.0
60.0
58.0
53.0
51.0
49.0
45.0
1000
0.25
65.0
61.0
59.0
54.0
52.0
50.0
46.0
1200
025
65.8
61.8
59.8
54.8
52.8
50.8
46.8
1400
0.25
66.4
62.4
60.4
55.4
53.4
51.4
47.4
1600
0.25
67.0
63.0
61.0
56.0
54.0
52.0
48.0
1800
0.25
67.5
63.5
59.5
58.5
54.5
52.5
48.5
2000
0.25
68.0
64.0
60.0
59.0
55.0
53.0
49.0
2150
025
68.3
64.3
60.3
59.3
55.3
53.3
49.3
CFM - Cubic Ft per Minute - Entering Wet Bulb ( °F)
SHC - Gross Sensible Capacity 1000 Btuh BF - Bypass Factor
NOTES:
1. Contact manufacturer for cooling capacities at conditions other
than shown in table.
2. Formulas:
Leaving db = entering db - sensible heat cao.
1.09 x CFM
Leaving wb = wb corresponding to enthalpy of air leaving coil
(hiwb)
hl,,,,b = hewb -total capacity (Btuh)
4.5 x CFM
where hewb = enthalpy of air entering coil. Direct interpolation
is permissible. Do not extrapolate.
3. SHC is based on 80 °F db temperature of air entering coil.
Below 80 °F db, subtract (Correction Factor x CFM) from SHC.
Above 80 °F db, add (Correction Factor x CFM) to SHC.
4. Bypass Factor = 0 indicates no psychometric solution. Use
bypass factor of next lower EWB for approximation.
Interpolation is permissible.
Correction Factor = 1.09 x (1 - BF) x (db - 80)
ESTIMATED SOUND POWER LEVEL (DBA)
Handbook, chapter 52, p. 52.7
LWB - Leaving Wet Bulb ( °r TC - Gross Cooling Capacity 1000 Btuh
MBH - 1000 Btuh
SHC CORRECTION FACTOR
* Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications
10
INDOOR COIL
AIR
SATURATED TEMPERATURE LEAVING EVAPORATOR (°F)
35
40
AS
50
65
CM
EWB
TC
SHC
BF
TC
SHC
BF
TC
SHC
BF
TC
SHC
BF
TC
SHC
BF
FE4ANF002
500
72
40.19
19.85
0.00
36.23
17.59
0.00
31.88
15.48
0.00
27.00
13.31
0.00
21.85
11.11
0.00
67
32.99
19.92
0.01
28.96
17.79
0.01
24.52
15.62
0.01
19.84
13.40
0.01
14.28
11.17
0.01
62
26.44
20.11
0.01
22.36
17.93
0.01
17.93
15.73
0.01
13.58
13.56
0.03
11.28
11.28
0.19
650
72
49.76
24.23
0.00
44.85
21.76
0.00
39.40
19.20
0.00
33.36
16.55
0.01
26.66
13.83
0.01
67
40.90
24.80
0.01
35.90
22.22
0.01
30.37
19.55
0.02
24.27
16.82
0.02
17.58
14.06
0.02
62
32.84
25.24
0.02
27.75
22.56
0.02
22.25
19.85
0.02
17.13
17.13
0.06
14.25
14.25
0.21
875
72
81.99
30.08
0.00
55.87
27.15
0.00
49.04
24.04
0.01
41.48
20.80
0.02
33.10
17.46
0.02
87
51.08
31.23
0.03
44.83
28.09
0.03
37.91
24.84
0.03
3023
21.47
0.03
21.83
18.03
0.03
62
41.11
32.14
0.03
34.78
28.88
0.03
27.91
25.53
0.04
22.04
22.04
0.10
18.33
18.33
0.25
1000
72
87.83
32.91
0.00
81.10
29.76
0.00
53.86
26.40
0.02
45.36
22.89
0.03
36.17
19.27
0.03
67
55.98
34.39
0.04
49.12
31.01
0.04
41.53
27.48
0.04
33.11
23.83
0.04
23.88
20.06
0.04
62
45.09
35.62
0.04
38.13
32.08
0.04
30.89
28.43
0.05
24.54
24.54
0.12
20.40
20.40
0.27
1250
600
72
77.77
37.84
0.00
70.13
34.30
0.03
61.59
30.55
0.05
52.04
26.60
0.05
41.42
22.50
0.05
67
84.36
40.02
0.06
56.52
3624
0.06
47.77
3227
0.06
38.04
28.12
0.06
27.48
23.81
0.07
62
72
51.98
43.01
41.92
20.98
0.06
0.00
44.00
38.69
37.93
18.78
0.06
FE4ANF003
0.00
35.61
33.92
33.77
16.51
0.06
0.00
29.12
28.64
29.12
14.18
0.16
0.00
24.20
22.85
24.20
11.81
0.30
0.01
87
3527
21.34
0.01
30.88
19.04
0.01
26.07
18.71
0.01
20.79
14.34
0.01
15.03
11.95
0.01
62
28.24
21.59
0.01
23.81
19.25
0.01
19.05
16.90
0.02
14.58
14.56
0.05
12.11
12.11
0.21
800
72
53.83
28.15
0.00
48.40
23.49
0.00
42.36
20.71
0.00
35.72
17.83
0.02
28.38
14.89
0.02
67
44.23
28.92
0.02
38.71
24.10
0.02
32.81
21.20
0.03
25.91
18.24
0.03
18.65
15.28
0.03
82
35.47
27.49
0.03
29.87
24.58
0.03
23.89
21.65
0.03
18.67
18.67
0.09
15.51
15.51
0.24
1000
72
63.07
30.60
0.00
56.66
27.57
0.00
49.58
24.36
0.02
41.76
21.04
0.03
33.10
17.62
0.03
67
51.91
31.82
0.04
45.41
28.58
0.04
38.24
25.24
0.04
30.31
21.78
0.04
21.76
18.29
0.05
82
41.71
32.80
0.04
35.12
29.43
0.04
28.13
28.00
0.05
22.41
22.41
0.12
18.60
18.80
0.27
1200
72
71.01
34.48
0.00
63.77
31.12
0.02
55.79
27.57
0.04
46.95
23.88
0.05
37.18
20.08
0.05
67
58.54
36.17
0.05
5121
32.59
0.05
43.10
28.87
0.06
34.13
25.02
0.06
24.47
21.08
0.06
82
47.12
37.60
0.06
39.70
33.86
0.06
31.89
30.00
0.07
25.83
25.83
0.15
21.43
21.43
0.29
1400
600
72
77.95
37.95
0.01
70.07
34.31
0.04
61.29
30.47
0.06
51.54
28.47
0.06
40.78
22.33
0.07
67
64.44
40.15
0.07
56.37
3628
0.07
47.43
3224
0.07
37.54
28.04
0.07
28.89
23.89
0.08
62
72
51.95
40.42
42.06
19.84
0.07
0.00
43.78
36.59
37.99
17.80
0.06
FESANB004
0.00
35.30
33.73
0.09
28.95
28.95
0.19
24.01
24.01
0.32
32.35
15.70
0.00
27.64
13.54
0.00
22.39
11.33
0.00
67
33.22
20.00
0.00
29.31
17.90
0.00
24.99
15.74
0.00
20.19
13.53
0.00
14.87
11.27
0.00
82
26.67
20.11
0.00
22.69
17.95
0.00
18.31
15.75
0.00
13.60
13.54
0.00
1129
11.29
0.17
800
72
52.07
25.46
0.00
47.19
22.92
0.00
41.75
2028
0.00
35.86
17.53
0.00
28.84
14.70
0.00
87
42.88
25.89
0.00
37.88
23.24
0.00
32.31
20.49
0.00
28.10
17.68
0.00
19.18
14.75
0.00
62
34.51
26.21
0.00
29.39
23.46
0.00
23.73
20.64
0.00
17.81
17.81
0.01
14.85
14.85
0.18
1000
72
82.54
30.48
0.00
56.75
27.53 •
0.00
5025
24.45
0.00
42.94
2121
0.00
34.73
17.84
0.00
67
51.83
3128
0.00
45.68
28.17
0.01
38.98
24.93
0.01
31.49
21.55
0.01
23.12
18.08
0.01
62
41.65
31.91
0.01
35.51
28.66
0.01
28.71
25.30
0.01
21.89
21.89
0.03
1826
18.26
0.19
1200
72
71.89
34.94
0.00
65.33
31.70
0.00
57.89
28.24
0.00
49.50
24.59
0.00
40.06
20.76
0.00
67
59.49
3820
0.01
52.88
32.73
0.01
45.02
29.06
0.01
36.39
25.22
0.01
26.71
2121
0.01
62
48.10
37.22
0.01
41.07
33.55
0.01
33.27
29.72
0.01
25.77
25.77
0.05
21.51
21.51
0.20
1400
750
72
80.24
38.94
0.00
73.00
35.45
0.00
84.73
31.89
0.00
55.41
27.69
0.01
44.86
23.46
0.01
67
86.53
40.71
0.01
58.99
38.93
0.01
50.47
32.91
0.02
40.84
28.86
0.02
29.98
24.20
0.02
g
53.91
5724
42.17
28.01
0.02
0.00
48.10
51.84
38.14
25.08
0.02
FE4ANF005
0.00
37.43
45.46
33.92
22.08
0.02
0.00
29.48
38.59
29.46
19.00
0.07
0.00
24.60
30.99
24.80
15.85
0.22
0.00
67
48.98
28.35
0.00
41.29
25.33
0.00
35.01
2224
0.00
28.09
19.09
0.00
20.47
15.90
0.01
62
37.87
28.59
0.01
31.89
25.50
0.01
25.61
22.37
0.01
19.28
19.28
0.02
16.05
16.05
0.19
950
72
89.88
33.97
0.00
82.89
30.52
0.00
55.32
28.92
0.00
48.89
23.21
0.00
37.57
19.40
0.00
67
57.29
34.68
0.01
50.33
31.06
0.01
42.64
27.33
0.01
34.14
23.51
0.01
24.80
19.83
0.01
82
45.99
3521
0.01
38.92
31.47
0.01
31.24
27.68
0.01
23.90
23.90
0.04
19.89
19.89
0.20
1150
72
80.80
3928
0.00
72.96
35.40
0.00
64.17
31.32
0.00
54.37
27.06
0.01
43.48
22.66
0.01
67
86.56
40.48
0.02
58.50
36.34
0.02
49.54
32.05
0.02
39.80
27.64
0.02
28.70
23.15
0.02
62
53.51
41.36
0.02
45.29
37.07
0.02
36.38
32.70
0.02
28.26
2826
0.07
23.51
23.51
0.22
1500
72
97.47
4729
0.00
88.05
42.83
0.00
77.49
38.05
0.01
65.68
33.04
0.02
52.41
27.78
0.02
87
80.52
49.40
0.03
70.85
44.58
0.03
60.01
39.53
0.03
47.89
34.25
0.03
34.64
28.83
0.04
62
84.96
51.12
0.03
55.02
46.04
0.03
44.30
40.80
0.04
35.27
35.27
0.10
29.34
29.34
0.25
1700
1050
72
105.61
5126
0.00
95.43
46.62
0.01
84.03
41.43
0.03
7121
36.06
0.03
56.82
30.42
0.03
67
87.38
53.92
0.04
76.93
48.80
0.04
85.20
43.40
0.04
52.01
37.70
0.04
37.80
31.83
0.05
62
72
70.60
76.01
58.17
37.07
0.04
0.00
59.87
68.82
50.74
33.39
0.04
FE4ANB006
0.00
48.32
60.76
45.08
29.56
0.05
0.00
38.96
51.72
38.96
25.55
0.13
0.00
32.40
41.64
32.40
21.42
0.27
0.00
67
62.63
37.91
0.01
55.22
34.04
0.01
46.97
30.03
0.01
37.78
25.89
0.01
27.80
21.64
0.01
62
50.40
38.54
0.01
42.81
34.53
0.01
34.49
30.41
0.01
2828
26.28
0.03
21.90
21.90
0.19
1300
72
89.66
43.58
0.00
8126
39.43
0.00
71.77
35.02
0.00
81.13
30.39
0.00
49.17
25.55
0.01
67
74.04
45.04
0.01
65.38
40.80
0.01
55.62
35.94
0.01
44.72
31.09
0.01
32.62
26.09
0.01
62
59.73
46.18
0.01
50.78
41.52
0.02
40.97
36.70
0.02
31.77
31.77
0.06
26.48
26.48
0.21
1750
72
110.09
53.41
0.00
99.92
48.84
0.00
88.41
43.46
0.01
75.38
37.95
0.02
80.66
32.13
0.02
87
9128
56.16
0.02
80.74
50.96
0.03
68.83
45.42
0.03
55.35
39.55
0.03
40.35
33.42
0.03
62
73.94
58.45
0.03
63.04
52.91
0.03
51.06
47.08
0.03
40.82
40.82
0.10
34.04
34.04
0.24
2050
72
121.19
58.89
0.00
110.14
53.79
0.01
97.57
4825
0.02
83.25
42.30
0.03
67.02
35.98
0.03
67
100.75
62.58
0.04
89.24
56.99
0.04
76.15
51.01
0.04
61.30
44.63
0.04
44.72
37.88
0.04
62
81.81
65.71
0.04
69.88
59.72
0.04
56.88
53.37
0.05
46.27
48.27
0.12
38.60
38.60
0.26
2200
72
126.10
61.36
0.00
114.71
58.14
0.02
101.67
50.45
0.03
86.78
44.32
0.03
69.87
37.78
0.04
67
104.99
65.51
0.04
93.05
59.79
0.04
79.44
53.62
0.04
83.97
47.02
0.04
48.71
40.00
0.05
62
85.35
89.12
0.04
72.98
82.94
0.05
59.55
56.35
0.06
48.85
48.85
0.14
40.75
40.75
0.27
GROSS COOLING CAPA'TIES (MBTUH)
9
E4A Algal
MODEL
AIRFLOW
DELIVERY
AVAILABLE
STATIC
PRESSURE
FE4ANFOO2
525 CFM
1.00 IN. H2O
700 CFM
1.00 IN. H2O
875 CFM
1.00 IN. H2O
1050 CFM
0.80 IN. H2O
1200 CFM
0.60 IN. H2O
FE4AN(B,F)003
700 CFM
1.00 IN. H2O
875 CFM
1.00 IN. H2O
1050 CFM
1.00 IN. H2O
1225 CFM
1.00 IN. H2O
1400 CFM
0.80 IN. H2O
FE4AN(B,F)005
875 CFM
1.00 IN. H2O
1050 CFM
1.00 IN. H2O
1225 CFM
1.00 IN. H2O
1400 CFM
1.00 IN. H2O
1600 CFM
0.50 IN. H2O
FE4ANB006
1050 CFM
1.00 IN. H2O
1225 CFM
1.00 IN. H2O
1400 CFM
1.00 IN. H2O
1750 CFM
1.00 IN. H2O
2000 CFM
0.60 IN. H2O
FE5ANB004
700 CFM
1.00 IN. H2O
875 CFM
1.00 IN. H2O
1050 CFM
1.00 IN. H2O
1225 CFM
1.00 IN. H2O
1400 CFM
1.00 IN. H2O
MODEL
SYSTEM SIZES
CFM
RANGE
MIN
RPM
FE4ANFOO2
018,
024,
030,
036
150
— 1200
300
FE4AN(B,F)003
024,
030,
036,
042
200
— 1400
285
FE4AN(B,F)005
030,
036,
042,
048
250
— 1600
275
FE4ANB006
036,
042,
048,
060
500
— 2000
275
FE5ANB004
024,
030,
036,
042
500
— 1400
275
ACCEPTABLE DUCT C6,DITIONS
MINIMUM RPM TABLE
RETURN STATIC PRESSURE, IN.W.C.
For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installed with duct systems which fall within the Acceptable
Range' Illustrated above.
MAXIMUM STATIC TABLE
8
MODEL FE4A
OUTDOOR UNIT CAPACITY BTUH
ELECTRIC HEATER kW RANGE
10
15
20
24
30
EMERGENCY
825
675
775
950
—
—
18,000
..._V
675
—
—
—
—
002
24,000
725
775
900
—
—
—
30,000
875
875
925
1125
—
—
36,000
975
975
1025
1125
—
—
EMERGENCY
675
700
775
850
1050
—
—
24,000
675
875
875
1100
1150
—
—
003
30,000
800
875
875
1100
1150
—
—
36,000
975
975
1025
1150
1250
—
—
42,000
1125
1125
1125
1150
1350
—
—
EMERGENCY
675
700
775
850
1400
1425
30,000
800
875
875
1100
—
—
005
36,000
975
975
1025
1150
01
N
—
—
42,000
1125
1125
1125
1150
—
—
48,000
1305
1305
1305
1305
1500
1600
EMERGENCY
1050
1050
1125
1750
1750
36,000
1050
1050
1350
—
—
006
42,000
1125
1125
8
1350
—
—
48,000
1300
1300
1500
1750
1750
60,000
1625
1625
1750
1750
1750
MODEL FE5A
OUTDOOR UNIT CAPACITY BTUH
ELECTRIC HEATER kW RANGE
5
9
10
15
20
24
30
EMERGENCY
675
775
775
900
1125
—
—
24,000
975
975
975
—
—
—
—
004
30,000
1050
1050
1100
1125
—
—
—
36,000
1050
1050
1100
1350
1350
—
—
42,000
1125
1125
1150
1350
1350
—
—
PERFORMANCE DATA
AIRFLOW DELI' :DOLING, HEATING, ELECTRIC HEATING MODES
The FE4 and FE5A fan coils will provide airflow at a rate that is
requested by the Integrated System User Interface during air
conditioning or heat pump heating (without electric heat) modes.
The nominal airflow for both heating and cooling modes is 350
cfm /ton nominal size of the outdoor unit installed. The airflow
actually requested by the User Interface is modified by its internal
algorithms for zoning, comfort or efficiency concerns. Refer to
FE4A/FE5A FAN COIL AIRFLOW DELIVERY CHART 9 - ELECTRIC HEATING
MODELS
Note 1: Emergency — Air conditioner with electric heater application, or emergency heat
Note 2: These airflows are minimum airflows as UL listed.
Note 3: Dashed entry indicates that the heater/fan coil /outdoor unit combination is not approved. Do not apply.
7
the documentation for the User Interface for more information on
how the User Interface controls the fan coil. Safe operation of
electric heaters requires airflow delivery at or above the minimum
CFM for electric heater application listed in the chart below. The
fan coil will adjust its airflow delivery to maintain safe airflow as
operating mode and staging conditions require.
LIAM
ODS CATALOG
ORDERING NO.
FIELD- INSTALLED HEAT
(KW)
NOMINAL
COOLING
CAPACITY
(BTUH)
DIMENSIONS
(IN)
SHIPPING
WEIGHT
(
Height
Width
Depth
Confi a uration
A
18,000
A
A
A
Rows- Fins/In.
FE4ANF002000
5, 8, 9, 10, 15, 20
to
42 -11/16
17 -5/8
22 -1/16
135
2,2.5,3,3.5
1.
Upflow, Downflow
CFM/Ton (Nominal CI• /Hte)
36,000
Motor HP (EC
1/2
1/2
1/2
3/4
3/4
24,000
18 -3/8
18 -7/8
18 -7/8
23 -5/16
FE4AN(B,F)003000
5, 8, 9, 10, 15, 18, 20
to
53 -7/16
21 -1/8
22 -1/16
150
Modular
Modular
42,000
30,000
FE4AN(B,F)005000
5, 8, 9, 10, 15, 18, 20, 24, 30
to
53 -7/16
21 -1/8
22 -1/16
172
48,000
36,000
FE4ANB006000
8, 9, 10, 15, 18, 20, 24, 30
to
59 -3/16
24- 11/16
22 -1/16
207
60,000
24,000
FE5ANB004000
5, 8, 9, 10, 15, 18, 20
to
59 -3/16
24- 11/16
22 -1/16
200
42,000
MODEL
SIZE
COI k 3g ,,
'. ;'' , " ,rte,
Refri. erant Meterin a Device
FE4A FE5A
002 003 005 006 004
N ;
"i5 F;' ^-. v. �. ,�, r £ ..., �: . ✓ /f ✓� ;, D j- H /�i -d W 2L //y/ // I _., ..,.
Puron® Refit erant (R -410A) TXV
TXV Size
2 Ton
3 Ton
4 Ton
4 Ton
3 Ton
Confi a uration
A
Slope
A
A
A
Rows- Fins/In.
3 / 14.5
Face Area (Sq Ft)
3.46 3.46 5.93 7.42
"1 ,
7.42
Nominal Coolin,Tons
1 ..
Air Disch - , e
1.5,2,2.5,3 2,2.5,3,3.5
Upflow, Downflow,
2.5,3,3.5,4 3,3.5,4,5
Horizontal
2,2.5,3,3.5
1.
Upflow, Downflow
CFM/Ton (Nominal CI• /Hte)
350+
Motor HP (EC
1/2
1/2
1/2
3/4
3/4
Finer 21 -1/2X
18 -3/8
18 -7/8
18 -7/8
23 -5/16
23 -5/16
I + * ' oN: •PT
hf `/,
..,,a
am , ��.�� .�
1 -piece 1 -piece / Modular 1- piece / Modular
Modular
Modular
PHYSICAL DATA
SPECIFICATIONS
6
UNIT
SIZE
F
G
COIL CONFIGURATION
SHIPPING WEIGHT
In.
In.
SLOPE
"A"
Lb
FE4A
002
18 -9/16
18 -1/4
—
Yes
135
003
26 -15/16
27 -1/2
Yes
—
150
FE4A
003*
26 -15/16
27 -1/2
Yes
—
150
FE4A
005
27 -1/4
26 -15/16
—
Yes
172
FE4A
005*
27 -1/4
26 -15/16
—
Yes
172
FE4A
006
32 -15/16
32 -5/8
—
Yes
207
FE5A
004
32 -15/16
32 -5/8
—
Yes
200
DIMENSIONS
ROTES:
. CONNISATE PAM CRAIN UPS ROT SNNN FOR CLARITY,
ITP
ItP
7,5
PRINRI NAI
SICOMSAIT NAI
HORIZ. LEFT D
(AS SHIPPED)
TTP.•
1 /I'
MNIraTAL WWII LOCATIONS . DIIL•LLS R101II0 II TOP PANEL.
AND SACS N CASINOS, II CASINO MOUTON. NOM PNTIDID
134• CIA. M0417011TAL MARGIN MAMNAlf TO II FIST, SUPPLIES.
NINARY IRA
SECONRMY DIAI
HORIZ. LEFT
(AS SHIPPED)
SI if'
70..
PRIMARY ORA
SECONDARY DRAT
I SII•
r i/D• 1 3/111'
It PIACISI
SCCONNI, IRA
PRIMO MAUI
f' I".
AIRFL01 Ii HACESI.
11/A•
S 111•
UPFLOI
(AS SHIPPED)
UPFLOW
(AS SHIPPED)
t SITS•
Ii PLACESI. 3 1 /4•
SECORDAIT NAI
PMINOT DIAI
t 7/1
SIOPF Con
PRINAII DRAIN -'
A-COI I
11111 ION
IS PLACER II PLACEEI.
.
1 1311/•
DOWNFLOW TIP..
(FIELD CONVERTED)
AIRIEST r 3 /If• 1,P
L 3/11•
PE WEST.
F M 314'
3 IIII
1/11• TOP,
I4 PLACLSI.
DONNFLOI
(FIELD CONVERTED)
t LIP TIP.
f Ii PLACES).
I• TIP
I It HACISI.
1 13111•
rtr.
PIINAIY DOA
SFCMDAAP DMA
STIR•
TTP..
SECONMUS 11111
Sn r
r TIP..
HORIZ. RIGHT
(FIELD CONVERTED)
FE4A / FE5A
It•
I u4• „ .•
•
I
TI
•
HORIZ. RIGHT Ti
(FIELD CONVERTED)
TIN
11P,.
UNIT
SIZE
A
B
C
D
E
H*
J*
In.
In.
In.
In.
In.
In.
In.
FE4A
002
42 -11/16
17 -5/8
15 -3/4
15 -5/8
10 -3/4
—
—
003
53 -7/16
21 -1/8
19 -1/4
19 -1/8
19 -3/16
—
—
FE4A
003*
53 -7/16
21 -1/8
19 -1/4
19 -1/8
19 -3/16
28 -5/16
—
FE4A
005
53 -7/16
21 -1/8
19 -1/4
19 -1/8
19 -1/2
—
—
FE4A
005*
53 -7/16
21 -1/8
19 -1/4
19 -1/8
19 -1/2
28 -5/16
—
FE4A
006
59 -3/16
24- 11/16
22 -3/4
22 -11/16
25 -1/4
34 -1/16
—
FE5A
004
59 -3/16
24 -11/16
22 -3/4
22 -11/16
25 -1/4
34 -1 /16
—
I I /1•
DIMENSIONS
15111'
0 SiR'
IN 711/•
8
C
OPINING
Inn IN
FRONT VIEW
SNOWN 'ITN •A• COIL DETAILS COIMCTIp1
LOCATIONS FOR PROW OR 110112. APPLICATIONS
Sle•DIA. 1.0.
FOR LOW 0001AGt
CONTROL '1110$
IxONNECI CO
0110111 DRYER
LOCATION
LORI. CONTROL.
l ELECTRIC NEATEN
ACCESS PANEL
OIL ACCESS
PANEL
10110 LINE CONNECTION
NOTION LIRE CONNECTION
I VW
FILTER ACCESS
PANEL
NOTE:
I. SERIES DESIGNATION IS TOE IATN PO4111121
OF UNIT PIOWUCT AVNER
IN
UNIT CONNECTION SIZES
SDCTIO: INS l DNS • Oil' I. 0. SWAT
0101111: SI • I.D.
I.D.SWATN• I. D. SWAT
COIIOERSATE: Sll' FAT
SLOPE COIL DETAILS
CONNECTION LOCATIONS SAM
FOR NATION OR 110012.
LEFT APPLICATIONS
NOTE: ALLOW 21• FROM FRONT
rq SLUICE
ntl All
ALTERNATE
TID•DIA. 0.0.
FOR VOLTAGE
CONTACT( 11111101
SFKT,S PAWL FONFIG FOE
SLOPE COILS
11� IG�ON3
AND
"A" COILS
DONNFLOW APPLICATIONS
FE4A / FE5A
-ID SIIL•
•
— OPTIORAL MELD CONVERTED
110111 SIDE RIOWN OPENING
(SLOPE c011 UNITS OWLII
TERORE
TIN•, 1 3102' Z•DIA. N.O.•S
FON NIGH VOLINGE
POWER WRING
OPPOSITE SIDE
I
RIGHT SIDE VIEW
R tT All
-u' t ue•
OWtt AIR f 7/1•
,1 1
• i
MO TE: NODULAR
NNITS WILL NAY(
N TWO-PIECE
CABINET
N H
IOW
TA MAR UNI1S
2 III'
License Information
License
ALLSEI *03055
Licensee Name
ALL SEASONS INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601811007
Ind. Ins. Account Id
87655701
Business Type
CORPORATION
Address 1
5001 N 28TH ST
Address 2
City
TACOMA
County
PIERCE
State
WA
Zip
98407
Phone
2532789344
Status
ACTIVE
Specialty 1
AIR CONDITIONING
Specialty 2
AIR HEAT,VENTILATION,EVAPORAT
Effective Date
8/25/1997
Expiration Date
12/17/2007
Suspend Date
Separation Date
Parent Company
Previous License
ALLSEC *0770M
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
AMBUR, KEN
PRESIDENT
08/25/1997
Bond
Amount
BRADSHAW, DAVID
VICE PRESIDENT
08/25/1997
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
GREAT
AMERICAN
INS CO OF
Until
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ALLSEI *03055 02/20/2007