Permit M07-045 - 9010 BUILDING
9010 BUILDING 9010 EAST MARGINAL WAY S EXPIRED M07 -045 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: 5422600160 9010 EAST MARGINAL WY S TUKW MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU DESCRIPTION OF WORK: REMOEV PLUMGER -STYLE DAMPERS FROM 112 FAN POWERED VAV BOXES AND REPLACE WITH NEW VALVES AT THE INLET, RELOCATE E28 EXISTING VAV AND MISCELLANEOUS DUCTWORK PER PLANS. Value of Mechanical: $62,064.00 Type of Fire Protection: 9010 BUILDING 9010 EAST MARGINAL WY S , TUKWILA WA KING COUNTY 500 K C ADMIN BLDG , SEATTLE WA MICHELLE MULLIN 7717 DETROIT AV SW , SEATTLE WA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 12/31/2008 Steven M. Mullet, Mayor Steve Lancaster, Director Phone: Phone: 206 -768 -4254 Phone: 206 -763 -9400 M07 -045 03/22/2007 09/18/2007 Fees Collected: $665.46 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP/ 100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -045 Printed: 03 -22 -2007 I hereby certify that I have read and governing this work will be complied Signature: Print Name: doc: IMC -10/06 c4essiL I` City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us Permit Center Authorized Signature: ili,- V i1 t Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M07 -045 Issue Date: 03/22/2007 Permit Expires On: 09/18/2007 Date: 0C -2-Io - permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: 3 / 2 0? This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -045 Printed: 03 -22 -2007 Parcel No.: 5422600160 Address: 9010 EAST MARGINAL WY S TUKW Suite No: Tenant: 9010 BUILDING 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: M07 -045 Status: ISSUED Applied Date: 03/05/2007 Issue Date: 03/22/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). M07 -045 Printed: 03 -22 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 icast .1 stir.► City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: 3 /2L! 0 M07 -045 Printed: 03 -22 -2007 SITE LOCATION Site Address: CIO I 0 C irk ail 1 d 1./.3 f opki Tenant Name: C I ) 1 C) %I (? Property Owners Name: K li' q C b■J 11+9 61 P C +m ' y Mailing Address: q O i C C J JM n ) Wow t k City CONTACT PERSON Name: M I e11 j 1 -e ' r u Mailing Address: 71 l -) er'ot / tM E -Mail Address: Company Name. Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF Company Name: Mailing Address: Contact Person: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Company Name: 0 \-.) dr)e..1 6.. 1V t Contact Person: E -Mail Address: Q:41pplications\Fotms- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh Fax Expiration Date: RD — All plans must be wet stamped by Architect of Record Mailing Address: `1'1 1 - 1 t) e-�t , A ke - SU► 00 31 E -Mail Address: Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 4 a z_ t 1 (e t Suite Number: Day Telephone: %9S tik City New Tenant: Floor: t+ r 3 ❑ Yes N No IA h C AR 11)V State Zip State Zip Fax Number: GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) City Day Telepho Fax Number: State Day Telephone: State Zip Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record s en t "' Day Telep : !V f lA Fax Number: Page 1 of 6 Lo a l? In d, State Zip Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator kiCtol V e s- ii Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Other Mechanical Equipment �p 4 Company Name: Mailing Address: Use: Residential: Commercial: Fuel Type: Electric MECHANICAL PERMIT INFORMATION - 206 - 431 - 3670 MECHANICAL CONTRACTOR INFORMATION br\ & Y\A. Aker 1 1 ( 1Z. tk el) VV 14t.Aut. S (J Contact Person: iM ► e E -Mail Address: M 1 c hei l e , 114 u 11 :n /kq[ AV14 . re*. Contractor Registration Number: YVVA C) Q '(= S - - 9 a p R V 0b Valuation of Project (contractor's bid price): $ 62 04,s Scope of Work (please provide detailed information): 102 •rOvr■ Q at orpd V411 6nx.t..s arid, heeelo.0 t.., i- y(1i 1 cL(v-es a+ ►'nL2i r e l o r c t. o� `6 e.)( is k r VA () 0. -"c9, rM I S C d v c�{ o ✓IC �M 10.1".5. New .... ❑ New .... ❑ Q:Wpplications\Forms- Applications On Lin '3 -2006 - Permit Application.doc Revised: 4 -2006 bh Replacement .... ❑ Replacement . w b c') 0L City State Zip Day Telephone �-bL) l lo� - 4 25" y Fax Number: Expiration Date: 1 Z. 3 / — ow, Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Page 4 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 OR AUTHORIZED AGENT: Signature: x Print Name: 1 SCL Cx . Mailing Address: City State Zip Date Application Accepted: o lGs Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh Date Application Expires: Date: 3/5/07 Day Telephone: opt I cs ( Staff Initials: Page 6 of 6 Receipt No.: R07 - 00319 Initials: JEM User ID: 1165 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 5422600160 Permit Number: M07 -045 Address: 9010 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 03/05/2007 Applicant: 9010 BUILDING Issue Date: Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. Amount Payment Check 1199 665.46 Account Code Current Pmts 000/322.100 538.37 000/345.830 127.09 Total: $665.46 Payment Amount: $665.46 Payment Date: 03/05/2007 04:33 PM Balance: $0.00 T doc: Receiot -06 Printed: 03 -05 -2007 COMMENTS: f Type of spection: �- - �c � h — INj Address: _ 14t ( `'l 0 I U c (NS i rY\ AQ6 (INJ l D ate Called: Special Instructions: Date Wanted: a.m. (f2 2- - 0 _7 Requester: Q (1.(c) --I 1,, ('e D te-ir 0ra., ? <s LI -Fad! i I 1 a - 1 , C./ f t\ f ,.)(,' i :'U ( (1 f t i gickt t r 7 . -:“L-3 -- f {cuv ✓' J f SI Si a- J .4 '' cJ. 1, ..0-- -..,ce 1/-r fi NI c .c_( e(.r 2-7 i try' _.2_..) .:) - ti PI i ( . Project: ' p CU1 uI (t !kJ S Type of spection: �- - �c � h — INj Address: _ 14t ( `'l 0 I U c (NS i rY\ AQ6 (INJ l D ate Called: Special Instructions: Date Wanted: a.m. (f2 2- - 0 _7 Requester: Phone N 20(0" 5( 0- 3 0 Y 4 ' El Approved per applicable codes. El Corrections required prior to approval. .00 REINSPECTION FEE 1 id at 6300 Southcenter Blv INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - : QUIRE Q. Prior to inspection, fee must be Suite 100. Call the schedule reinspection. 'Receipt No.: 1Date: Project: Proje \ S CI C I 0 CS)_( 1 k( I\ Type of w ecction: I (; �� \ ) v Address: Date Called: �p 6- 7't49/ Special Instructions: Date Wanted: (c' — l C I - O 7 (a.m. p.m. Requester: Phone No: ,2..0( - 0 - 30t-/ 5 . COMMENTS: p f) ,� /� A /'S - � / /O d — p`.!,/�,/1.K `"� �p 6- 7't49/ ) _ r „-- -___ O INSPECTION O. 0167 -01 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. Inspec • r; .00 REINSPECTION EE REQUIRE. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit rat 11 -06 -2007 MICHELLE MULLIN 7717 DETROIT AV SW SEATTLE WA 98106 RE: Permit No. M07 -045 9010 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writinx and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 12/19/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall, t Technician Permit File No. M07 -045 Cizy of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M07 -045 DATE: 03 -05 -07 PROJECT NAME: 9010 BUILDING SITE ADDRESS: 9010 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bui Division Public Works n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1g Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: Documents/routing slip.doc 2 -28 -02 REVIEWER'S INITIALS: PERMIT COORU u0pY` 4-- PLAN REVIEW /ROUTING SLIP Structural Structural Review Required Approved with Conditions 51( 3 - 1 Fire Prevention ❑ Planning Division ❑ Permit Coordinator C DUE DATE: 03-06-07 Not Applicable ❑ No further Review Required DATE: DUE DATE: 04-03-07 Not Approved (attach comments) ❑ DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company Previous License DIVCOI *988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SIGMUND, FREDRIC PRESIDENT 12/31/2002 KOPET, TYLER SECRETARY 12/31/2002 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MACDOFS980RU 03/22/2007 DIFFUSER/GRILLE SCHEDULE SYMBOL MANUFACTURER & MODEL NUMBER SIZE TYPE NOTES SIZE TITUS ML -38 AS NOTED MODULINEAR DIFFUSER WITH 2, 3/4" SLOT SPACING AND 4 FT LONG DISCHARGE SLOTS 120W 0 CFM - AS NOTED SLOT DIFFUSER FIELD VERIFY ©CFM 1 4/12$ - AS NOTED SLOT DIFFUSER FIELD VERIFY 0 CFM - AS NOTED SLOT DIFFUSER FIELD VERIFY ON SIZE © - AS NOTED SLOT DIFFUSER FIELD VERIFY CFM SIZE - AS NOTED SLOT DIFFUSER FIELD VERIFY © CFM SIZ EXAMPLE OF DEMO AS NOTED SLOT DIFFUSER FIELD VERIFY 0 CFM SIZE - AS NOTED RETURN GRILLE FIELD VERIFY ©CFM SIZE AS NOTED RETURN GRILLE FIELD VERIFY 0 CFM SIZE - AS NOTED MODULAR CORE FIELD VERIFY 0 CFM SIZE AS NOTED SIDE WALL RETURN GRILLE FIELD VERIFY Q GFM - AS NOTED SIDE WALL SUPPLY GRILLE FIELD VERIFY ©CFM SIZE - AS NOTED MODULAR CORE FIELD VERIFY © CFM DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") 14/12 120W SOUNDLINE SHEETMETAL (1" LINING) BARE FLAT OVAL SHEETMETAL 14/12 SL 1 4/12$ , SHEETMETAL WRAPPED W/ INSULATION (2 ") FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 14/12 W 14/12 &W BARE ROUND SHEETMETAL DUCTBOARD (1" FIBERGLASS) 120 14/12 DB EXAMPLE OF NEW EXAMPLE OF NOT IN CONTRACT (NIC) _ 14712 _..,, - 14/12 EXAMPLE OF DEMO FLEX DUrT x x x x z x z EXAMPLE OF EXISTING FLEX CONNECTOR 14/12 3 n 0 0 N a 0 a Q 0 L N HVAC ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD- MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL OSA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION RA RETURN AIR REG REGISTER (GRILLE WITH DAMPER) REQ'D REQUIRED RIO ROUGH IN ONLY SA SUPPLY AIR SCD SMOKE CONTROL DAMPER SD SMOKE DAMPER SL SOUND LINING SM SHEET METAL SP STATIC PRESSURE SS START /STOP SSSC SOLID STATE SPEED CONTROLLER STL STEEL SUC SUCTION LINE SUSP SUSPENDED T'STAT THERMOSTAT TC TEMPERATURE CONTROL TOD TOP OF DUCT TOS TOP OF STEEL TV TURN VANES TWG TOP WALL GRILLE TWR TOP WALL REGISTER TYP TYPICAL UNO UNLESS NOTED OTHERWISE VD VOLUME DAMPER VFD VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER l ° c"7 - 2:^ es shall be made to the scor.3 c 7 without prior approval c d Building Civic :an. NC L:: I: :vlc :eras will require a new plan submittal C. ,:1 may include additional plan review fees. I SEPARATE PERMIT REQUIRED FOR 1:1 Mechanical If/ Electrical [ / Plumbing i Gas Piping City of Tukwila BUILDING' DIVISION riLE cor Permit No. VIKLILle Plan review approval is subject to errors and for& Approval of construction documents does not authorize the violation of cny accepted code or ordinance. Receipt of approval Fie::] Copy and conditions Is aelalotviedged: By Date: City of Tukwila BUILDING DIVISION HVAC GENERAL NOTES 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: COOLING INDOOR DESIGN TEMP ( °F) = 75 COOLING OUTDOOR DESIGN TEMP ( °F) = 83DB, 67WB HEATING INDOOR DESIGN TEMP ( °F) = 70 HEATING OUTDOOR DESIGN TEMP ( °F) = 20 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK 3, MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2003 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2003 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2004 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 2.0" 0.6 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -3.3 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 4000 FPM (R -3.3 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R -3.3 MIN.). 7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2003 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2003 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2003 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 10.PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11.PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2003 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 12.HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 13. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 14.OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 15.COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 16.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. LEGAL DESCRIPTION APN # 5422600160 LEGAL DESCRIPTION: 7 -8 MEADOWS THE MC NATTS D C 38 UNREC POR BEG ON N LN 179.98 FT E OF NW COR OF 8 TH 5 89 DEG 17 MIN 51 SEC E ALG N LN 232.31 FT TH S 29 DEG 52 MIN 38 SEC E 520.79 FT TH N 89 DEG 58 MIN 17 SEC W 230.59 FT TH N 29 DEG 52 MIN 38 SEC W 524.20 FT TO BEG CONTACT LIST TITLE NAME COMPANY PHONE NUMBER FAX NUMBER PROJECT ENGINEER ACCOUNT EXECUTIVE SHEET METAL FOREMAN FIELD ENGR FOREMAN SIEMEN'S PROJ MNGR MICHELLE MULLIN BILLY LANGAN BRETT KILEKAS STEVE BAKER BEN SHARPE MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER SIEMENS 206 - 768 -4254 206 - 768 -3982 206 - 768 -4018 206- 768 -3824 425 - 507-4390 206 -768 -4255 206 - 768 -3983 206- 768 -4019 206 -768 -3825 SCOPE OF WORK REMOVE EXISTING MEDIUM PRESSURE DUCTWORK AND PLUNGER STYLE DAMPERS FROM EXISTING ONE HUNDRED TWELVE (112) FAN POWERED VAV BOXES. FURNISH AND INSTALL ONE HUNDRED TWELVE (112) NEW VALVES AT THE INLET OF EACH EXISTING FAN POWERED VAV, INCLUDES ALL ASSOCIATED DUCTWORK MODIFICATIONS AS SHOWN ON PLANS. RELOCATE TWENTY EIGHT (28) EXISTING FAN POWERED BOXES TO ESTABLISH A 3 FOOT SECTION OF STRAIGHT DUCT TO THE INLET OF EACH BOX, INCLUDING ALL ASSOCIATED DUCTWORK MODIFICATIONS AS SHOWN ON PLANS. AIR BALANCE 112 ZONES. INSULATE ALL NEW AND ANY MODIFIED DUCTWORK PER CODE. FIELD VERIFY VALVE INLET SIZES. THERE MAY BE DISCREPANCIES BETWEEN PLANS AND FIELD INSTALLATION. CHANGE ORDER WILL BE ISSUED TO TAKE CARE OF ANY DISCREPANCIES IN THE FIELD. FIELD VERIFY VAV BOX RELOCATES AND REPORT ON AS- BUILTS. DRAWING SHEET INDEX NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM0.02 SCHEDULES AND DETAILS - HVAC DM2.01 N FIRST FLOOR NORTH DEMO PLAN- HVAC DM2.01S FIRST FLOOR SOUTH DEMO PLAN - HVAC TM2.01 N FIRST FLOOR NORTH - HVAC TM2.01S FIRST FLOOR SOUTH - HVAC DM2.02N SECOND FLOOR NORTH DEMO PLAN- HVAC DM2.02S SECOND FLOOR SOUTH DEMO PLAN - HVAC TM2.02N SECOND FLOOR NORTH - HVAC TM2.02S SECOND FLOOR SOUTH - HVAC DM2.03N THIRD FLOOR NORTH DEMO PLAN- HVAC DM2.03S THIRD FLOOR SOUTH DEMO PLAN- HVAC TM2.03N THIRD FLOOR NORTH - HVAC TM2.03S THIRD FLOOR SOUTH - HVAC R CE"IVED CITY OF TU KIM LA, MAR 0 5 2007 S Stith sx; Sthede SL cS S St:Urvan St '°' $ Caverrldte St S'Co °dean St S Trenton St s Henderson St 5 Duettar.Si a a 5 52nd PI S 93rd St 5 103rd 5( Soeing field /King Co /al FnntarvAty. St ar s Webster St 5 Austin 5t S ttoldea St s Portland St • s Orrcage St ° 2 S Kenyon 5: te 5 Pilgrim St 5 Perry St -- i3ooni .4 ;990:1 SITE MAP NO SCALE WORK SITE 9010 EAST MARGINAL WAY TUKWILA, WA 98108 599, 5t s S9r)tb st s Lois: st 102nd 5t s ' SIC4111 SI s e ;09 LlsoCKest, Lrc VICINITY MAP NO SCALE MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 CD /PERMIT REVISIONS: DATE 02-16-07 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA SCHEDULES & NOTES - HVAC ENGINEER: LAST REVISED: M MULLIN 02 -16 -07 CHECKED BY DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE N BECKER 02 -16 -07 DRAWING NUMBER: C -1461- 7275035 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TM0.01 0 I a 1- N) 0 n N N o) LC) T I J 0 0 i a w 1- 0 0 0 w z W J_ LL 0 0 FIRST FLOOR VAV BOX SCHEDULE UNIT NO. MODEL NO. LOCATION VALVE CFM CONNECTION SIZE MIN INLET S.P. IN WG ELECTRICAL HEATING CORE FAN NOTES MAX MIN INLET (IN) OUTLET KW VOLT /PH STGS CFM HP VOLT /PH /HZ SPD VAV -101 TRANE VFPE -1720 CORE 1320 0 10 27/15 0.25 0 - - 1355 1/2 277/1/60 - 1,2,3,4 VAV -102 TRANE VFPE -1715 SW CORNER 1130 225 10 27/15 0.12 9.0 27711 3 1160 1/3 277/1/60 - 1,2,3,4 VAV -103 TRANE VFPE -2430 CORE 1980 0 12 27/15 0.22 0 - - 2030 2 @1/3 277/1/60 - 2,3,4 VAV -104 TRANE VFPE -1720 WEST WALL 1260 250 10 27/15 0.21 9.0 277/1 3 1295 1/2 277/1/60 - 1,2,3,4 VAV -105 TRANE VFPE -2430 CORE 1980 0 12 27/15 0.22 0 - - 2030 2 @1/3 277/1/60 - 2,3,4 VAV -106 TRANS VFPE -1720 WEST WALL 1260 250 10 27/15 021 9.0 277/1 3 1295 1/2 277/1/60 - 1,2,3,4 VAV -107 TRANE VFPE -1115 CORE 990 0 8 27/15 0.21 0 - - 1015 1/3 277/1 /60 - 2,3,4 VAV -109 TRANE VFPE -1730 NW CORNER 1600 320 10 27/15 0.25 9.0 277/1 3 1640 2 @1/3 277/1/60 - 1,2,3,4 VAV -110 TRANE VFPE -0304 WORK ROOM 105 20 5 20/11 0.05 1.0 277/1 3 110 1/15 277/1/60 - 1,2,3,4 VAV -111 TRANE VFPE -0307 CONF ROOM 330 65 5 20/11 0.4 1.0 277/1 3 340 1/8 277/1/60 - 1,2,3,4 VAV -112 TRANE VFPE -1730 CORE 1190 240 10 27/15 0.11 9.0 277/1 3 1190 3/4 277/1/60 - 1,2,3,4 VAV -113 TRANE VFPE -0607 SE CORNER 370 75 6 20/11 0.21 3.5 277/1 3 380 1/8 277/1/60 - 1,2,3,4 VAV -114 TRANE VFPE -2430 CORE 1980 0 12 27/15 0.22 0 - - 2030 2 @1/3 277/1/60 - 2,3,4 VAV -115 TRANE VFPE -1111 EAST WALL 860 175 8 20/11 0.17 4.5 277/1 3 885 1/4 277/1/60 - 1,2,3,4 VAV -116 TRANE VFPE -2430 TRAINING ROOM 1 900 0 12 27/15 0.22 0 - - 990 2 @1/3 277/1/60 - 1,2,3,4 VAV -117 TRANE VFPE -1111 BREAK ROOM 1000 175 8 20/11 0.17 4.5 277/1 3 1000 1/4 277/1/60 - 1,2,3,4 VAV -118 TRANE VFPE -1111 BREAK ROOM 785 175 8 20/11 0.17 4.5 277/1 3 785 1/4 277/1/60 - 1,2,3,4 VAV -119 TRANE VFPE -1111 TRAINING ROOM 2 835 135 8 20/11 0.17 5.5 277/1 3 835 1/4 277/1/60 - 1,2,3,4 VAV -120 TRANE VFPE -1615 TRAINING ROOM 2 595 115 6 27/15 0.32 1.0 277/1 3 595 1/3 277/1/60 - 1,2,3,4 VAV -121 TRANE VFPE -0607 OBSERVATION ISLE 555 110 6 20/11 0.40 4.5 277/1 3 555 1/8 277/1/60 - 1,2,3,4,5 VAV -122 TRANS VFPE -1115 OBSERVATION ISLE 880 175 8 27/15 0.18 5.0 277/1 3 880 1/3 277/1/60 - 1,2,3,4,5 VAV -123 TRANE VFPE -0611 NORTH WALL EAST 600 120 6 20/11 0.45 4.5 277/1 3 600 1/4 277/1/60 - 1,2,3,4,5 VAV -124 TRANE VFPE -0607 ENVELOPE STORAGE 480 95 6 20/11 0.32 5.5 277/1 3 480 1/8 277/1/60 - 1,2,3,4 VAV -125 TRANE VFPE -1115 ENVELOPE STORAGE 820 165 8 27/15 0.15 6.5 277/1 3 820 1/3 277/1/60 - 1,2,3,4 VAV -126 TRANE VFPE -0607 ENVELOPE STORAGE 400 80 6 20/11 0.20 2.0 277/1 3 400 1/8 277/1/60 - 1,2,3,4 VAV -127 TRANE VFPE -1720 OPENING 1400 0 10 27/15 0.26 0.0 277/1 - 1400 1/2 277/1/60 - 2,3,4 VAV -128 • TRANE VFPE -1715 OPENING 1120 0 10 27/15 0.20 0.0 277/1 - 1120 1/3 277/1/60 - 2,3,4 VAV -129 TRANE VFPE -1730 OPENING 1540 0 10 27/15 0.23 0.0 277/1 - 1540 2 @1/3 277/1/60 - 2,3,4 VAV -130 TRANE VFPE -1115 OPENING 840 0 8 27/15 0.16 0.0 277/1 - 840 1/3 277/1/60 - 2,3,4 VAV -131 TRANE VFPE -1115 BALLOT VAULT 820 165 8 27/15 0.16 6.0 277/1 3 820 1/3 277/1/60 - 1,2,3,4,5 VAV -132 TRANE VFPE -1115 BALLOT VAULT 945 190 8 27/15 0.18 9.5 277/1 3 945 1/3 277/1/60 - 1,2,3,4 VAV -133 TRANE VFPE -0304 SPLITTING ROOM 240 45 5 20/11 0.21 1.0 277/1 3 240 1/15 277/1/60 - 1,2,3,4 VAV -134 TRANE VFPE -0304 SPLITTING ROOM 240 45 5 20/11 0.21 1.0 277/1 3 240 1/15 277/1/60 - 1,2,3,4,5 VAV -135 TRANE VFPE -0304 SUPPLY ROOM 100 20 5 20/11 0.05 1.0 277/1 3 100 1/15 277/1/60 - 1,2,3,4 VAV -136 TRANE VFPE -1730 OPENING 1540 0 10 27/15 0.23 0.0 277/1 - 1540 2 @1/3 277/1/60 - 2,3,4 VAV -137 TRANE VFPE -1115 OPENING 980 0 8 27/15 0.21 0.0 277/1 - 980 1/3 277/1/60 - 2,3,4 VAV -138 TRANE VFPE -0607 OBSERVATION ISLE 660 110 6 20/11 0.40 4.5 277/1 3 660 1/8 277/1/60 - 1,2,3,4 VAV -139 TRANE VFPE -1115 OBSERVATION ISLE 880 175 8 27/15 0.18 5.0 277/1 3 880 1/3 277/1/60 - 1,2,3,4,5 VAV -140 TRANE VFPE -0607 OBSERVATION ISLE 420 0 6 20/11 0.23 0.0 277/1 - 420 1/8 277/1/60 - 2,3,4 VAV -141 TRANS VFPE -0304 OBSERVATION ISLE 200 40 5 20/11 0.17 1.0 277/1 3 200 1/15 277/1/60 - 1,2,3,4,5 VAV -142 TRANE VFPE -2430 CAFETERIA 2050 850 12 27/15 0.26 10.0 277/1 3 2100 2 @1/3 277/1/60 - 1,2,3,4,5 VAV -143 TRANE VFPE -0304 ROLLS ROYCE 200 60 5 20/11 0.14 1.0 277/1 3 200 1/15 277/1/60 - 1,2,3,4 SECOND FLOOR VAV BOX SCHEDULE UNIT NO. MODEL NO. LOCATION VALVE CFM CONNECTION SIZE MIN INLET S.P. IN WG ELECTRICAL HEATING CORE FAN NOTES MAX MIN INLET (IN) OUTLET KW VOLT /PH STGS CFM HP VOLT /PH /HZ SPD VAV -201 TRANE VFPE -1720 TABULATION 1400 280 10 27/15 0.29 9.5 277/1 3 1400 1/2 277/1/60 - 1,2,3,4 VAV -202 TRANE VFPE -1730 TABULATION 1665 335 10 27/15 0.28 0 277/1 - 1665 2 @1/3 277/1/60 - 2,3,4 VAV -203 TRANE VFPE -1720 TABULATION 1020 255 10 27/15 0.21 8.5 277/1 3 1020 1/2 277/1/60 - 1,2,3,4 VAV -204 TRANE VFPE -1730 VERIFICATION 1665 0 10 27/15 0.28 0 277/1 - 1665 2 @1/3 277/1/60 - 2,3,4 VAV -205 TRANE VFPE -2430 RECONCILIATION 2220 0 12 27/15 0.30 0 277/1 - 2220 2 @1/3 277/1/60 - 2,3,4 VAV -206 TRANE VFPE -1730 RECONCILIATION 1020 305 10 27/15 022 10.0 277/1 3 1020 2 @113 277/1/60 - 1,2,3,4 VAV -207 TRANE VFPE -1720 MAIL SORTING 1110 0 10 27/15 0.20 0 277/1 - 1110 1/2 277/1/60 - 2,3,4 VAV -208 TRANE VFPE -1115 MAIL SORTING 1020 205 8 27/15 0.23 8.0 277/1 3 1020 1/3 277/1/60 - 1,2,3,4 VAV -209 TRANE VFPE -0607 BALLOT VAULT 420 85 6 20/11 0.21 2.5 277/1 3 420 1/8 277/1/60 - 1,2,3,4 VAV -210 TRANE VFPE -1115 BALLOT VAULT 840 170 8 27/15 0.16 4.5 277/1 3 840 1/3 277/1/60 - 1,2,3,4 VAV -211 TRANE VFPE -0607 VESTIBULE 385 75 6 20/11 0.15 1.0 277/1 3 385 1/8 277/1/60 - 1,2,3,4,5 VAV -212 TRANE VFPE -0304 SUPPLY ROOM 145 30 5 20/11 0.16 1.0 277/1 3 145 1/15 277/1/60 - 1,2,3,4 VAV -213 TRANE VFPE -1730 BALLOT VAULT 1665 0 10 27/15 0.28 0 277/1 - 1665 2 @1/3 277/1/60 - 2,3,4 VAV -214 TRANE VFPE -1115 BALLOT VAULT 1005 200 8 27/15 0.21 4.5 277/1 3 1005 1/3 277/1/60 - 1,2,3,4 VAV -215 TRANE VFPE -2430 INSERTION 2220 0 12 27/15 0.30 0 27711 - 2220 2 @ 277/1/60 - 2,3,4 VAV -216 TRANE VFPE -2430 DUPLICATION 2010 405 12 27/15 0.25 8.5 277/1 3 2010 2 @1/3 277/1/60 - 1,2,3,4 VAV -217 TRANE VFPE -1715 INSERTION 1110 0 10 27/15 0.16 0 277/1 - 1110 1/3 277/1/60 - 2,3,4 VAV -218 TRANE VFPE -1115 DUPLICATION 1035 210 8 27/15 0.23 5.0 277/1 3 1035 1/3 277/1/60 - 1,2,3,4,5 VAV -219 TRANE VFPE -0304 SUPERINTENDANT 190 40 5 20/11 0.16 1.0 277/1 3 190 1/15 277/1/60 - 1,2,3,4,5 VAV -220 TRANE VFPE -0607 CONF ROOM 340 70 6 20/11 0.15 1.0 277/1 3 340 1/8 277/1/60 - 1,2,3,4,5 VAV -221 TRANE VFPE -1720 SW CORNER 1260 250 10 27/15 0.23 8.5 277/1 3 1290 1/2 277/1/60 - 1,2,3,4 VAV -222 TRANE VFPE -1115 WEST WALL 960 195 8 27/15 0.20 6.0 277/1 3 985 1/3 277/1/60 - 1,2,3,4 VAV -223 TRANE VFPE -1115 WEST WALL 960 195 8 27/15 0.20 6.0 277/1 3 985 1/3 277/1/60 - 1,2,3,4,5 VAV -224 TRANE VFPE -1715 NW CORNER 1140 230 10 27/15 0.20 9.0 277/1 3 1170 1/3 277/1/60 - 1,2,3,4 VAV -225 TRANE VFPE -2430 CORE 1920 0 12 27/15 0.23 0 277/1 - 1970 2 @1/3 277/1/60 - 2,3,4 VAV -226 TRANE VFPE -2430 CORE 1760 0 12 27/15 0.18 0 277/1 - 1805 2 @1/3 277/1/60 - 2,3,4 VAV -227 TRANE VFPE -0607 CONF ROOM 420 85 6 20/11 0.23 1.0 277/1 3 430 1/8 277/1/60 - 1,2,3,4 VAV -228 TRANE VFPE -2430 CORE 2080 0 12 27/15 0.25 0 277/1 - 2135 2 @1/3 277/1/60 - 2,3,4 VAV -229 TRANE VFPE -2430 CORE 1920 0 12 27/15 0.23 0 277/1 - 1970 2 @1/3 277/1/60 - 2,3,4 VAV -230 TRANE VFPE -2430 NE CORNER 1950 385 12 27/15 0.24 8.5 277/1 3 2000 2 @1/3 277/1/60 - 1,2,3,4 VAV -231 TRANE VFPE -1720 EAST WALL 660 132 10 27/15 0.23 3.0 277/1 3 700 1/2 277/1/60 - 1,2,3,4,5 VAV -232 TRANE VFPE -1720 EAST WALL 1320 265 10 27/15 0.23 5.5 277/1 3 1355 1/2 277/1/60 - 1,2,3,4,5 VAV -233 TRANE VFPE -1115 SE CORNER 1020 205 8 27/15 0.20 5.0 277/1 3 1045 1/3 277/1/60 - 1,2,3,4 VAV -234 TRANE VFPE -0607 CORE 480 0 6 20/11 0.29 0 277/1 - 495 1/8 277/1/60 - 2,3,4 VAV -235 TRANE VFPE -0607 CONF ROOM 420 85 6 20/11 0.23 1.0 277/1 3 430 1/8 277/1/60 - 2,3,4 VAV -236 TRANE VFPE -0304 CMPTR ROOM 200 100 5 20/11 0.15 0 277/1 - 205 1/15 277/1/60 - 2,3,4,5 VAV -237 TRANE VFPE -1111 EAST WALL 660 132 8 20/11 0.15 3.0 277/1 3 700 1/4 277/1/60 - 2,3,4,5 VAV -238 TRANE VFPE -0607 LOBBY 500 0 6 20/11 0.30 0 277/1 - 525 1/8 277/1/60 - 2,3,4,5 VAV -239 TRANE VFPE -0607 LOBBY 500 0 6 20/11 0.30 0 277/1 - 525 1/8 277/1/60 - 2,3,4 VAV -240 TRANE VSEF08000 VERIFICATION 765 105 8 12/12 0.31 5.0 277/1 2 765 1/3 277/1/60 - 1 VAV -241 TRANE VSEF 1000R MAIL SORTING 1020 165 10 16/12 029 7.0 277/1 2 1020 1/2 277/1/60 - 1 VAV -242 TRANE VSEF06000 DATA UPLOAD /DATA 250 40 6 12/10 0.04 1.0 277/1 2 250 1/3 277/1/60 - 1 THIRD FLOOR VAV BOX SCHEDULE UNIT NO. MODEL NO. LOCATION VALVE CFM CONNECTION SIZE MIN INLET S.P. IN WG ELECTRICAL HEATING CORE FAN NOTES MAX MIN INLET (IN) OUTLET KW VOLT /PH STGS CFM HP VOLT /PH /HZ SPD VAV -301 - - 1170 - 8 - - - - - - - - - 3,4,5 VAV -302 - - 960 - 8 - - - - - - - - - 3,4,5,6 VAV -303 - - 1920 - 12 - - - - - - - - - 3,4,5 VAV -304 - - 1300 - 10 - - - - - - - - - 3,4,5 VAV -305 - - 910 - 8 - - - - - - - - - 3,4,5 VAV -306 - - 680 - 8 - - - - - - - - - 3,4,5,6 VAV -307 - - 800 - 8 - - - - - - - - - 3,4,5 VAV -308 - - 1170 - 10 - - - - - - - - - 3,4,5 VAV -309 - - 520 - 8 - - - - - - - - - 3,4,5,6 VAV -310 - - 550 - 8 - - - - - - - - - 3,4,5 VAV -312 - - 100 - 5 - - - - - - - - - 3,4,5 VAV -313 - - 500 - 6 - - - - - - - - - 3,4,5 VAV -314 - - 1600 - 10 - - - - - - - - - 3,4,5 VAV -315 - - 820 - 8 - - - - - - - - - 3,4,5 VAV -316 - - 430 - 6 - - - - - - - - - 3,4,5,6 VAV -317 - - 860 - 8 - - - - - - - - - 3,4,5 VAV -318 - - 940 - 8 - - - - - - - - - 3,4,5,6 VAV -319 - - 850 - 8 - - - - - - - - - 3,4,5 VAV -320 - - 720 - 8 - - - - - - - - - 3,4,5 VAV -321 - - 660 - 8 - - - - - - - - - 3,4,5 VAV -323 - - 680 - 8 - - - - - - - - - 3,4,5 VAV -324 - - 460 - 8 - - - - - - - - - 3,4,5 VAV -326 - - 560 - 6 - - - - - - - - .. 3,4,5 VAV -327 - - 620 - 8 - - - - - - - - - 3;4,5 VAV -329 - - 960 - 8 - - - - - - - - - - , 3,4,5 VAV -330 - - 700 - 8 - - - - - - - - - 3,4,5 VAV -331 - - 420 - 6 - - - - - - - - - 3,4,5 VAV -332 - - 200 - 5 - - - - - - - - - 3,4,5,6 VAV -333 - - 1384 - 8 - - - - - - - - - 3,4,5,6 VAV -334 - - 860 - 8 - - - - - - - - - 3,4,5 VAV -335 - - 640 - - - - - - - - - - 3,4,5,6 VAV -336 - - 800 - - - - - - - - - - 3,4,5,6 VAV -337 - - 215 - 5 - - - - - - - - - 3,4,5 VAV -338 - - 440 - 6 - - - - - - - - - 3,4,5,6 VAV -339 - - 440 - 6 - - - - - - - - - 3,4,5 VAV -340 - - 345 - 6 - - - - - - - - - 3,4,5 VAV -341 - - 215 - 5 - - - - - - - - - 3,4,5 VAV -342 - - 490 - 6 - - - - - - - - - 3,4,5 0 0 NOTES: 1) UNIT PROVIDED WITH CONTACTORS, AIR FLOW SWITCH AND DISCONNECT. SWITCH WIRED AND MOUNTED ON UNIT. 2) UNIT PROVIDED WITH 3 SPEED FAN SWITCH WIRED AND MOUNTED ON UNIT. 3) INSTALL D3001 VALVE AT INLET OF FAN POWERED BOX: COOLING ONLY TERMINAL UNIT W/O HEAT -, SIZE AS LISTED, FIELD MOUNTED CONTROLS, CONTROLS BY OTHERS. FACTORY OPTIONS INCLUDE: - STANDARD 1/2" LINER - INLET SENSOR 4) DEMO EXISTING PLUNGER STYLE DAMPER FROM EXISTING FAN POWERED BOX. INSTALL D3001 VALVE AT INLET OF FAN POWERED BOX, INLET SIZE ON SCHEDULE. FIELD VERIFY 3 FEET OF STRAIGHT MED PRESSURE DUCT BEFORE VALVE INLET. 5) DESIGN AIRFLOWS ARE TAKEN FROM THE FLOOR PLANS - FIELD VERIFY AIRFLOWS AND FAN POWERED BOX MODEL AND HEATER KW (IF APPLICABLE). REPORT ON AS- BUILTS. 6) RELOCATE VAV TO OBTAIN MINIMUM 3 FEET MEDIUM PRESSURE DUCT AT INLET. EXISTING FAN POWERED BOX WITH PLUNGER STYLE DAMPER VALVE REMOVED 2' -0" FIELD FABRICATED ECC CAP NEW AIR VALVE FIELD VERIFY INLET SIZE MIN 36" 15-1/2" FIELD FABRICATED ECC CAP VALVE INSTALLATION D ETAI L NO SCALE MINIMUM DIMENSION OF STRAIGHT MEDIUM PRESSURE DUCT NOTES: 1) UNIT PROVIDED WITH CONTACTORS, AIR FLOW SWITCH AND DISCONNECT. SWITCH WIRED AND MOUNTED ON UNIT. 2) UNIT PROVIDED WITH 3 SPEED FAN SWITCH WIRED AND MOUNTED ON UNIT. 3) INSTALL D3001 VALVE AT INLET OF FAN POWERED BOX: COOLING ONLY TERMINAL UNIT W/O HEAT -, SIZE AS LISTED, FIELD MOUNTED CONTROLS, CONTROLS BY OTHERS. FACTORY OPTIONS INCLUDE: - STANDARD 1/2" LINER - INLET SENSOR 4) DEMO EXISTING PLUNGER STYLE DAMPER FROM EXISTING FAN POWERED BOX. INSTALL D3001 VALVE AT INLET OF FAN POWERED BOX, INLET SIZE ON SCHEDULE. FIELD VERIFY 3 FEET OF STRAIGHT MED PRESSURE DUCT BEFORE VALVE INLET. 5) RELOCATE VAV TO OBTAIN MINIMUM 3 FEET MEDIUM PRESSURE DUCT AT INLET. NOTES: 1) UNIT PROVIDED WITH CONTACTORS, AIR FLOW SWITCH AND DISCONNECT. SWITCH WIRED AND MOUNTED ON UNIT. 2) UNIT PROVIDED WITH 3 SPEED FAN SWITCH WIRED AND MOUNTED ON UNIT. 3) INSTALL 03001 VALVE AT INLET OF FAN POWERED BOX: COOLING ONLY TERMINAL UNIT W/O HEAT -, SIZE AS LISTED, FIELD MOUNTED CONTROLS, CONTROLS BY OTHERS. FACTORY OPTIONS INCLUDE: - STANDARD 1/2" LINER - INLET SENSOR 4) DEMO EXISTING PLUNGER STYLE DAMPER FROM EXISTING FAN POWERED BOX. INSTALL D3001VALVE AT INLET OF FAN POWERED BOX, INLET SIZE ON SCHEDULE. FIELD VERIFY 3 FEET OF STRAIGHT MED PRESSURE DUCT BEFORE VALVE INLET. 5) RELOCATE VAV TO OBTAIN MINIMUM 3 FEET MEDIUM PRESSURE DUCT AT INLET. REVIEWED FOR CO DE COMPLIANCE SIOnevunco MAR 2 12007 City Of Tukwila BUILDING DIVISION RECEIVED CITY OF T11Kw!,.�a MAR 0 5 2007 t CEATEH MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 CD /PERMIT REVISIONS: DATE 02 -16 -07 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA SCHEDULES & NOTES - HVAC ENGINEER: M MULLIN CHECKED BY B GEZON CAD: N BECKER LAST REVISED: 02-- -16 -07 DATE PLOTTED: 02 -16 -07 ISSUE DATE 02 -16 -07 DRAWING NUMBER: C-- -1461- 7275035 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TMO.02 0 0 0 2 1- u) N) 0 1.0 1• N N rn 1- 2 0) 0 0 0 z 0 0 0 N N w Q z w L 0 0 N 0 0 N cfl Q s_ 0 L 0 LL FD 24 " - I 18 " - D NEW SUPPLY AIR DUCTS WITH 1" DUCT LINING AND PERF, METAL C❑VER. (E) 12' -0" X 1' -4 NUM • 0140 < P220 0 e '_ 220 80 80 140 114Q 28/120 ! 1 T TED 8/14 UP (E) TO TEF - 5 (ON ROOF) 14/8 (E) 10/10 (E) ;300 CFM 16/12 E t 24/24 410 850 CFM EXHAUST DUCTED THROUGH 2ND FLOOR TO ROOF MOUNTED 10/10 EG(E) 250 ICFM WITH HORtZONTAL FIRE DAMPER(E)— 410 EMCS CONTROL PANELS 12' -6" X 1 , -6 " RETURN AIR OPENING (E) 410 410 SUPPLY DUCT OPENING(E) C4) 48/8 RELIEF AIR GRILLES (E) (TYP 11) 220 220 t 8 I 220 ILL 0 00 8 80 0 0! ma illga 2001 1 (I 14/14 6/4 (E) 6 6 EG E 80 CFM 1ST FLOOR DEMO PLAN NORTH -- HVAC SCALE: Ys" = 1' -0" 16/16 WALL LOUVER 16/16 EG (E) 500 CFM (13 12/10 (E) 10/10 UP (E) 10/8 UP (E) 70/10 (E) '1., 10/10 EG (E) 500 CFM `E; GENERAL NOTES: FIELD NOTES: 0 VERIFY 36" CLEARANCE FOR ELEC. 0 FV MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. 0 FV CONNECTED LP DUCT AND DIFFUSER AND RECONNECT. REPORT ON AS BUILTS. VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. k 4a REVIEWED FOR CODE COMPLIANCE AirmnfiliPn MAR 2 7 2007 city OI• Tul'*►�vil BUILDING DIVISION RECEIVED r rry nr• ri 9t,,‘,,I a MAR 0 5 2007 f MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 - 767 -6773 wvwv.macmiller.com WA Lic No: MACDOFS98QRU 1 EXPIRES: 07 -06 -08 I CD /PERMIT REVISIONS: DATE 02 -16 -07 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 1ST FLOOR DEMO PLAN NORTH - HVAC ENGINEER: LAST REVISED; M MULLIN 02 -16 -07 CHECKED BY DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE N BECKER 02 -16 -07 DRAWING NUMBER: 0 - 1461- 7275035 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: D 2.01N 0 • N 1- u� 0 LC] N N I- 2 (1) 0 0 0 z w 0 0 u) 0 u) N N w w 1 0 MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206 - 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 4s, o Lt • I mac. _ v5 _ 36163 tv Gr 5' ' 1. ONA I EXPIRES: 07 -06 -08 CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 3 c 1ST FLOOR PLAN NORTH c - HVAC C II 4 . re c Lr ENGINEER: LAST REVISED: I• C` M MULLIN 02 -16 -07 - U (- CHECKED SY: DATE PLOTTED: _ U B GEZON 02- 16--07 c CAD: ISSUE DATE: c N BECKER 02 -16 -07 c L_ c DRAWING NUMBER: c C -1461- 7275035 -00 tr. M c ISSUED FOR CONSTRUCTION n i 2 SHEET NUMBER: M2D1N -4 W LT C U 18 F NEW SUPPLY AIR DUCTS WITH 1" DUCT LIMING AND PERF. METAL COVER. (E) 12' -0" X 1' -4" 27/15 40! 80 14Q 140 1;40 140 8/14 UP (E) TO TEF -5 (ON ROOF) 14/8 (E) 10/10 (E) T FD FD 24" - � T I > 0 24/24 c> <D ' 410 16/12 850 CFM EXHAUST DUCTED THROUGH 2ND FLOOR TO ROOF V1OUNTED 0 EG(E) CFM WITH HORIZONTAL FIRE DAMPER(E)— EN CS CONTROL PANELS 12' -6 X 1 -6)/ RETURN AIR OPENING (E) 0 410 20t 410 SUPPLY DUCT OPENING(E) 10 48/8 RELIEF AIR GRILLES (E) (TYP 11) 220 05 ,y 80 8 220 0 220 r 2 8 185 240 5 14/14 1 ST FLOOR PLAN NORTH - HVAC SCALE: Y6" = 1' -0" 1H; 4 6/16 WALL LOUVER 16/16 500 CFM 10/8 UP (E) CB ) 12/10 (E) 10/10 UP (E) 6/4 (E) 6 6 EG 80 CFM 10/10 (E) 10/10 EC (E) 500 CFM FIELD NOTES: 0 VERIFY 36" CLEARANCE FOR ELEC. O FV MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. O FV CONNECTED LP DUCT AND DIFFUSER AND RECONNECT. REPORT ON AS BUILTS. GENERAL NOTES: 2. VAV BOX OUTLET DUCT SIZE 15 SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. CODE CEMPL FOR A CE natirtucn MAR 2 1 2007 City Of Tukwil BUILDING DIVISION VAV BOX INLET DUCT SIZE 15 SAME AS VAV BOX INLET SIZE. DIFFUSER DUCT 15 SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. RECEIVED rrfv nv: ,:,, MAR 0 5 2007 n 0 0 0 iU Ii 16/16 WALL LOUVER -- rF \‘) \o `�o . 10 uP(E j 6 80 C 1 12,1 EG(E 1.400 . p.FM cs 0 > 21 210 14 12 ►J 801 8o 165 165 O 165 165 165 f/I 0 320 120 1 d 1 w 0 i ;400 80 48/8 RELIEF GRILLE (E) (TYP 14) 5 215 0 80 120 1120 1ST FLOOR DEMO PLAN SOUTH - HVAC SCALE: Ya" = P-0" 8/14 UP(E) TO TEF -5 ON ROOF 34/28 RETURN AIR OPENING 12' -0 X 1' -4" RETURN AIR OPENING (E) FIELD NOTES: FV MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. GENERAL NOTES: -Mt/ Of T�,kr BUILDING D /V /SIO 1 VAV BOX INLET DUCT SIZE 15 SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE 15 SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. CODE FOR COMPLIANCE 40 13 1 131101®CO MAR 2 7 2007 +LCEIVED r . ` :rl1KvVLA MAR 0 5 2007 PERMIT CENTER ', FY f.. LA MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 1 CD /PERMIT REVISIONS: DATE 02 -16 -07 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 1ST FLOOR DEMO PLAN SOUTH - HVAC ENGINEER: M MULLIN CHECKED BY: B GEZON CAD: N BECKER LAST REVISED: 02-16-07 DATE PLOTTED: 02 -16 -07 ISSUE DATE: 02 -16 -07 DRAWING NUMBER: C -1461- 7275035 - 00 ISSUED FOR CONSTRUCTION SHEET NUMBER: DM2.01S 0 0 CV 1- LO N) 0 N z u7 0 a c� z w 0 0 LO 0 u7 I_ N n 1ST FLOOR PLAN SOUTH - HVAC . _ ENGINEER: LAS r REVISED: M MULLIN O2-16—O7 CHECKED BY DATE PLOTTED: B GEZON 02-1 6-07 CAD: ISSUE DATE N BECKER 02-16-07 DRAWING NUMBER: c — 1 461-7275035-00 •ISSUED FOR CONSTRUCTION 0 0 16/16 WALL LOUVER fl 680 C 12/12 EG(E 400 OFM I 10 165 165 M 129) 320 120 1 5 16 16 .... ..... 1 165 200 200 12' 40p 48/8 RELIEF GRILLE (E) (1)/P 14) 80, 215 215 8 80 16 165 165 210 21 5, 210 I 165 165 80 \80 2T5 215 215 04 215 1 80 8 0 215 80, 120 120 1 8‘I 5 215 [VI 0 Li 1ST FLOOR PLAN SOUTH - HVAC SCALE: Y8 = 1 ' - 0 " 8/14 UP(E) TO TEF-5 ON ROOF 34/28 RETURN AIR OPENING 12'-0" X 1'-4" RETURN AIR OPENING (E) FIELD NOTES: 0 F MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. () GENERAL NOTES: a-, vIAJ.1.1 REVIEWED FOR CODE COMPLIANCE A emir) rtucn MAR 2 7 2007 BUILDING DIVISION VAV BOX INLET DUCT SIZE 15 SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. 2.0 RECEIVED CITY er, n("WILA MAR 05 2001 PERMIT CENTER EIY PLAN MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU CD/PERMIT REVISIONS: 02-16-07 SHEET NUMBER: TM2.01S 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 0 0 MacDon ald Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 - 767 -6773 www.macmiller.com WA Litz No: MACDOFS980RU r . i t-14'? - - 4v vs 36163 , v + ' T S- . . t o NA � 1 EXPIRES: 07 -06 -08 ' I \ CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA. WA 2ND FLOOR DEMO PLAN NORTH - HVAC i L r ENGINEER: LAS REVISED: M MULLIN 02-16-07 CHECKED 6Y: DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE: N BECKER 02 -16 -07 L f 1 f i i `- 1 DRAWING NUMBER: C - 1461 - 7275035 - 00 i I i 1 I ISSUED FOR CONSTRUCTION 1 SHEET NUMBER: 0M2J32N • N 0 (D L 0 0 a L1 n_ L Jb- 34/�8 4240 CFM 76/18 F.D 36/18 _ I 2955 C MI 70/18 FD 18? 950CrM TYP 6 21? FD RETURN AIR ELEC. BASE BOARD HEATING (E) SEE SHEET M503 FOR RETURN AIR DETAILS SEE SHELI M501 FOR A/C THIS AREA 16/16(E) 500 CFM FD 46 RETURN AIR FD 56/18 FD C f ) 120 315 120 X120 O 315 315 160 D 3000 CFM1 3000 CFM ■I 12/14 DN 11 ,SEE SHEET M501 FOR A/C THIS AREA 80 80 0 0 I 160 120 80 /1 c> 770 CFM `(P • 6 2100 0 210 120 18/120 80 80 3 120 f 3 0 I 1„ <0> 1 340 330 \ 0 171 ICI 80 0/1 0240 80 48/8 RELIEF AIR GRILLE (E) (TYP 11) 80 120 / 330 330 ... {e <E> 240 315 240 r 27L14 "_ 221 1 160 160 160 Q160 ... 80 80 80 80 - 80 - -r- for 330 120 VAV \225 - 80 80 10 a I 0 160 160 160 120 160 160 160 27/1 4 -3/4" Q 240 80 80 160 80 40 160 330 80 \ 80 (VAV 23 10 D 6 84 300 801 160 I 80 760 , 128/12 VA 23 40 285 80 100 10 \ 285 285 musw k e " 14/14 520 14/1 (ter 520CFI 12/1 400 G FM \ 325 r P20 @ .111 Q � 8 5 4 . r 6/4 (E) 14/10 10/10.. (E) 16/16 EXISTING 10 14 UP TO ON ROOF RLIURN GRILLES TYPICAL FOR EAST AND WEST WALLS 16/16 WALL LOUVER 12/10 (E) (E)) 10/10 DOWN (E) 14/10 UP (E) - 6 /6EG 80 CFM 10/10EG (E) 300 CFM 2ND FLOOR DEMO PLAN NORTH - HVAC SCALE: 1/e — 1' -0" GENERAL NOTES: VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE 15 SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT 15 SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. CODE FOR COMPLIANCE opeorilico MAR 2 1 2007 clty o fiu►�Wii� BUILDING DIVISION RECEIVED CFry 1-17 -, •. , A�rI MAR 0 5 2007 PERMIT CENTER f4, r 41�, O a N F31 34/28 4240 CFM 36/18 2955 FC M FD - 18 950 CFM - TYP 6 - SEE SHEET M501 FOR A/C THIS AREA C> 160 CAP 0160 80 . 14/12 160 760 120 330 120 160 160 � 0 VAV 225 _r_vV` 80 160 160 160 1201 70/18 ED 70/18 � FD RETURN AIR ELEC. BASE BOARD HEATING (E) SEE SHEET M503 FOR RETURN AIR DETAILS SEE SHEET M501 FOR - A /C THIS AREA 16/15(E) 500 CFIv1 FD 46 18 FD 56/18 FD RETURN AIR 315 315 E I 315 120 r 0 60 D 3000 CFM 160 18? 770 CFM TIP 6 210 210 340 120 0 0 120 1120 - 80 3000 CFM 80 EJ 80 12/14 I 160 O 210 P 1 120 d 340 (VAV) i 0/1 80 240 80 48/8 RELIEF AIR GRILLE (E) (NP 11) 80 80 160 D- 160 0 160 16a ` 6a � 27/14 -3/4" 120 Y S f 330 l 330 IC 240 0- 240 VAV 222 180 100 80 80 0 160 80 330 T 160 0 --120 325 80 \ 80 40 285 100 10 /4" 6/4 (E) M 10/10 (E) ON ROOF 16/16 WALL LOUVER 16/16 14/10 (E) 10/10 DOWN (E) EXISTING 10 14 UP TO RETURN GRILLES TYPICAL FOR EAST AND WEST WALLS 2ND AL EY s " FLOOR PLAN NORTH - HVAC SC : ' -0 14/10 UP (E) 12/10 (E) 6 /6EG (E 80 CFM 10 /10EG (E) 300 CFM Cc) (F) FIELD NOTES: 0 FIELD VERIFY MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. 0 FIELD VERIFY 8"0 AT INLET FOR 8 "0 VAV BOX. REPORT ON AS- BUILTS. GENERAL NOTES: VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LICHT FIXTURES OR WALLS. REVIEWED FOR C ODE COMPLIANCE MAR 2 7 2007 City pf Tukwil BUILDING DTVTSIQN E Y RECEIVED C T'e OF r MAR 0 5 2007 - Vil L:ENTEh ii A \ i 5a MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU EXPIRES: 07-06-08 1 1� CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 2ND FLOOR PLAN NORTH - HVAC ENGINEER: LAST USED M MULLIN 02 -16 -07 CHECKED BY: DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE: N BECKER 02-16-07 DRAWING NUMBER: C 1461 - 7275035 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TM2.02N w z W Li 0 Q 0 MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206- 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU • ,. I : A V It■ 361 63 ` l'arsT 5 � 1 EXPIRES: 07 -06 -08 I ' \ CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA c c c ( r L r ( 2ND FLOOR DEMO PLAN SOUTH - HVAC ENGINEER LAST REVISED: M MULLIN 02 -16 -07 CHECKED BY: DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE N BECKER 02 -16 -07 L r C r , is C L DRAWING NUMBER: c - 1461 - 7275035 - 00 C i P ( ISSUED FOR CONSTRUCTION L r L SHEET NUMBER: 0M2.02S L i C 0 0 16/16 WALL LOUVER B 48/8 EXISTING RELIEF AIR (TYP 15) f\ J . ._..._ - _.. • 6 2 NA L E : D Y " FLOOR DEMO PLAN SOUTH - HVAC SCa = 1 — 16/16 (E) 500 CFM SEE SHEET M501 FOR A/C THIS AREA 24 "0 FOR CONTINUATION SEE SHEET 2M10 21 "0 34/28 RETURN AIR OPENING 36/18 RETURN AIR OPENING 18? RETURN AIR OPENING (TYP. OF 6) REVIEWED FOR CODE COMPLIANCE MAR 2 7 ZOO/ City Of Tukwila BUILDING DIVISION RECEIVED y, %.[T/ o Tf i'�JVff! iJ MAR 0 5 2007 r'EFIMI I CENTEhi \I 16/16 WALL 48/8 EXISTING RELIEF AIR (TYP 15) c. 6, C5J 2ND FLOOR PLAN SOUTH - HVAC SCALE: Ys" = 1' -0" 16/16 (E) 500 CFM SEE SHEET M501 FOR A/C THIS AREA 24 "0 FOR CONTINUATION SEE SHEET 2M10 21 "o 34/28 RETURN AIR OPENING 36/18 RETURN AIR OPENING 18? RETURN AIR OPENING (TYP. OF 6) FIELD NOTES: O FIELD VERIFY MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. GENERAL NOTES: VAV BOX INLET DUCT SIZE 15 SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. ..a HOPI l ;:i;lli;ll 1'1 IL iiilliil }li I::r' zN�;: CODE REVIEWED OP FOR COMPLIANCE rinneku MAR 2 1 ZOO/ t ty Of Tukwila BUILDING DTVTSION r HMU r CENTEFI RECEIVED CITY r17 TUTAtIL 1 MAR 0 5 2007 MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206- 767 -6773 vvww.macmiller.com WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 2ND FLOOR PLAN SOUTH - HVAC ENGINEER: M MULLIN CHECKED BY B GEZON CAD: N BECKER LAST REVISED: 02 -16 -07 DATE PLATTED: 02 -16 -07 ISSUE DATE 02 -16 -07 DRAWING NUMBER: C -1461- 7275035 -00 ISSUED FOR CONSTRUCTION SHEEP NUMBER: TM2.02S 0 0 N cri 0 I N 1- L[] 0 N ca Li 0 i FOR CONTINUATION SEE SHEET 1 M 10 FOR CONTINUATION SEE SHEET 2M10 22? SOFFIT 2151 a . 1 11 2 �jIL �� !S 120 I BLANK OFF EXISTING BASE BOARD HEAT 20 0 REUSE EXISTING 12/6 SIDEWALL REGISTER 24 "? DOWN FRO vi EXISTING DISCHARGE PLENUM SEE SHEET M500 FOR LOBBY AREA DUCT REUSE EXISTING THERMOSTAT LOCATION FOR NEW THERMOSTAT SENSOR 14/8 24/18 1 384 LOCATE HIGH ON WALL S 2 CFM 148 FO 201 - 48/8 EXISTING RELIEF AIR GRILLE (E) (TYP 12) 330 ' 3.30 _ C.G 8/61 G (E) 100 CFM 3RD FLOOR DEMO PLAN NORTH - HVAC SCALE: Ys" — 1' -0" 16/16 WALL ,1,//-- LOUVER 8/16 24/10 (E) UP TO 8 /8CG(E) 160 10/10(E) 260 TEF -1(E) (6) F? FIELD NOTES: 0 RELOCATE VAV BOX AS REQ'D TO MEET 3FT MIN. MED PRESSURE AT INLET. FIELD VERIFY ELECTRICAL CLEARANCE ACCESS MINIMUM AT NEW LOCATION. 0 MODIFY DUCT AS REQ'D TO MAINTAIN 3FT MIN. STRAIGHT MED PRESSURE DUCT AT INLET. GENERAL NOTES: VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT 15 SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. REVIEWED FOR C ODE COMPLIANCE annetsm MAR 2 12007 City Cifkwil� BUILDING DMSION MAR 0 5 2007 f'a4tuv, t;EN KEY f �� t f�� ' E i --- /d•'J MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU CD /PERMIT REVISIONS: 02 - 16 - 07 DATE ENGINEER: M MULLIN CHECKED BY: B GEZON CAD: N BECKER LAST REVISED: 02-16-07 DATE PLOTTED: 02-16-07 ISSUE DATE: 02 -16 -07 DRAWING NUMBER: C - 1461 - 7275035 - 00 ISSUED FOR CONSTRUCTION cyL SHEET NUMBER: DM2.03N 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 3RD FLOOR DEMO PLAN NORTH - HVAC N 0 0 FOR CONTINUATION SEE SHELI 1M10 FOR CONTINUATION SEE SHEET 2M10 1 N 't-EXISTING BASE BOARD HEAT 0 260 C M BLANK � OFF REUSE EXISTING 12/6 SIDEWALL REGISTER 24 "? DOWN FROM EXISTING DISCHARGE PLENUM SEE SHEET M500 OR LOBBY AREA DUCT REUSE EXISTING THERMOSTAT LOCATION FOR NEW THERMOSTAT SENSOR S 24/18 g 1384 LOCATE HIGH ON WALL 48/8 EXISTING RELIEF AIR GRILLE (E) (TYP 12) 120 EXIST. --'" 8/6 C.O. -- 3RD FLOOR PLAN NORTH - HVAC SCALE: 3/8" = 1' -0" 16/16 WALL LOUVER 24/10 (E) UP TO TEF -1(E) Cc) r±)) FIELD NOTES: 0 RELOCATE VAV BOX AS REQ'D TO MEET 37 MIN. MED PRESSURE AT INLET. FIELD VERIFY ELECTRICAL CLEARANCE ACCESS MINIMUM AT NEW LOCATION. 0 MODIFY DUCT AS REQ'D TO MAINTAIN 3FT MIN. STRAIGHT MED PRESSURE DUCT AT INLET. GENERAL NOTES: VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE 15 SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. CODE FOR COMPLIANCE ti rY04nmArcn MAR 2 7 ZOO/ City BUILDING � Tc�kW�la RECEWED MAR 0 5 2007 K 4 P I !` I aPP S. r Mr: MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 - 767 -6773 www.macmiller.com WA Lic No: MACDDFS980RU 7 CD /PERMIT REVISIONS: 02- 16--07 DRAWING NUMBER: C - 1461 - 7275035 - 00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TM2.03N 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 3RD FLOOR PLAN NORTH HVAC ENGINEER: LAST REVISED: M MULLIN 02 -16 -07 CHECKED BY DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE N BECKER 02 -16 -07 (n 1-- T (1) C7 0 0 z W 0 0 MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 - 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU • , Z'U AS 4 V , ` rd i 36163 w : %, 'kis S144,, = `' ZONA I EXPIRES: 07 -06 -08 CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 3RD FLOOR DEMO PLAN SOUTH - HVAC 1 . 0 0 N Cb) ca) EXISTING 24/10 UP TO TEF-3 ON ROOF ( D EXISTIN 8 /6(E) 130 B 1 30 18 130 13p 16/16 WALL LOUVER 16/8 8 6 0 60� c,4- EXIST. EXISTING ':8 / 1 o /8(E) \ a\ 6 320 200 ` — 16d \ 8 G. 320 � 320 r§) T / 120 260 100 1 .27 - I 2 120 1 0 320 320 320 48/8 RELIEF AIR GRILLE(E) (TYP 14) 12 22 , !100 1 00 240 120 C> 320 320 3 227 320 ( ) 3.. 12 C 320 120 O 320 �LFD La- 3RD FLOOR DEMO PLAN SOUTH -- HVAC SCALE: Ys" = 1' -0" 26"0 SUPPLY AIR DUCT FROM EXISTING PLENUM SEE DWG. M500 6" SPRINKLER MAIN (� 10' -8" A.F.F.) REVIEWED FOR CODE COMPLIANCE inn�,utc MAR 2 12007 Ciiy of Tukwila BUILDING OT'ITc Ton1 RECEIVED "rTv �• !K\MILA MAR 0 5 2007 UENTEh LEI'' P LA I\ (A C3) EXISTING 24/10 UP TO TEF -3 ON ROOF 16/16 WALL LOUVER 16/8 6-75 � re) EXISTING 1 o /8(E) NC A\ ��0 EXIST. B /6(0 20 320 320 320 320 EXISTING 8/6(E)� 121 126p 18/10 80 $, 130 113 AV \308 27/15 C> 130 130 AV 310 ) AM 312 1 14'r2Y- 1 20 iwvvws G �. 320 320 320 48/8 RELIEF AIR GRILLE(E) (TYP 14) 100 100 .1 00 120 320 320 320 ( 6) 320 370 320 245 275 245 (5) 3RED Y FLOOR PLAN SOUTH -- HVAC SCAL — 1' -0" 26"0 SUPPLY AIR DUCT FROM EXISTING PLENUM SEE DWG. M500 6" SPRINKLER MAIN (CE 10' -8" A.F.F.) FIELD NOTES: O RELOCATE VAV BOX AS REQUIRED TO MEET 3FT MIN. MED PRESSURE AT INLET. 0 MODIFY DUCT AS REQ'D TO MAINTAIN 3FT MIN STRAIGHT M.P. DUCT AT INLET. GENERAL NOTES: VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. o11 REVIEWED FOR CODE COMPLIANCE A raffia "vcn MAR 21 2007 City Of Tukwila BUILDING DIVISION crr EC j LA MAR 0 5 2007 c r t:ti�t I CENTER K . E' ' MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206- 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 REVISIONS: DATE / \ \ CD /PERMIT 02 -16 -07 9010 BUILDING 9010 EAST MARGINAL WAY TUKWILA, WA 3RD FLOOR PLAN SOUTH - HVAC ENGINEER: LAST REVISE: M MULLIN 02 -16 -07 CHECKED BY DATE PLOTTED: B GEZON 02 -16 - 07 CAD: ISSUE DATE N BECKER 02 -16 -07 DRAWING NUMBER: C- 1461- 7275035 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TM2O3S 0 0 ri 0 I N I0 0 LCD N N 1- 1— = U7 c9 0 C7 z w 0 0 u7 r7 0 ur) N