Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-049 - DSW SHOES
DSW SHOES 17100 SOUTHCENTER PY SUITE 128 M07 -049 Parcel No.: 2623049081 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Cityf Tukwila Contractor: Name: T N T MECHANICAL LLC Address: 22833 BOTHELL- EVERE'IT , HY 1164 Contractor License No: TNTMEL *011K7 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17100 SOUTHCENTER PY TUKW WIG PROPERTIES LLC -SS 4811 134 PL SE , BELLEVUE WA Contact Person: Name: SARAH NIELSEN Address: 1120 E 80 ST #211 , BLOOMINGTON MN MECHANICAL PERMIT DSW SHOES 17100 SOUTHCENTER PY, SUITE 128 , TUKWILA WA DESCRIPTION OF WORK: DUCTING TO THREE ROOFTOP UNITS WHICH GET DUCTORK BEYOND THE DROPS. RUN CONDENSATE LINES IN PVC AND INSTALLING UNIT HEATER. Value of Mechanical: $13,500.00 Type of Fire Protection: SPIU,R/AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 EOUIPMENT TYPE AND OUANTITY 0 0 0 1 0 0 8 0 0 1 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 800 541 -0821 Phone: 425 - 486 -4327 Expiration Date: 05/27/2008 M07 -049 08/13/2007 02/09/2008 Fees Collected: $315.68 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP/ 100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 13 Thermostat 9 Wood/Gas Stove 0 Water Heater 1 Emergency Generator 0 Other Mechanical Equipment 0 M07 -049 Printed: 08 -13 -2007 Permit Center Authorized Signature I hereby certify that I have read and governing this work will be compile The granting of this p construction or the p . o Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: MO7 -048 Issue Date: 08/13/2007 Permit Expires On: 02/09/2008 Date: 01 r ;' permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. es not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ce of work. I am authorized to sign and obtain this mechanical permit. Date: / 74 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -049 Printed: 08 -13 -2007 City of Tukwila Parcel No.: 2623049081 Address: 17100 SOUTHCENTER PY TUKW Suite No: Tenant: DSW SHOES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 - 049 Status: ISSUED Applied Date: 03/14/2007 Issue Date: 08/13/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M07 -049 Printed: 08 -13 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us air moving equipment upon detection of smoke m the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Local U.L. central station supervision is required. (City Ordinance #2051) 18: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (4.4.1.4.2.1)) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 23: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M07 -049 Printed: 08 -13 -2007 Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the p rfo '' - ce of work. Signature: l /l r Date: 8/ (- 5 4,7_ 'o /174-/e-eiscsn M07 -049 Printed: 08 -13 -2007 otu i (:lI Y VI" I VKVVII Community Develop t Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Site Address: f L005 v.. exnkk r tir t t Tenant Name: C)Sx.. Property Owners Name: Wick Y k: Mailing Address: 4% • 13L-In Pn_ �F F�1 \e, ti \J A► 0144 City E -Mail Address:�D\ld2c CbIM Company Name: 'T. S • D- Mailing Address: Contractor Registration Number: Company Name: sincerynoc.t. A - 4 M # t ' t - * . . Contact Person: P.2e.CE E -Mail Address: r�r�rrx•4'InP�(o� �h YY�t1oc1� Cb(Y Q :Mpplications\Porms-Applications On Linel3 -2006 - Permit Applicatiomdoc Revised: 9 -2006 bh Building Perr No. Mechanical Permit No. 0 Plumbing/Gas Permit No. f Public Works Permit No. Project No. pd O!4 or o i we use on! Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 2(/' - tQ Z1' Suite Number: Floor: 1 New Tenant: ;;y4 Yes ❑..No State CONTACT PERSON - who do we contact when your permit is ready to be issued Name:S¢ttLh Day Telephone: 2ISIA Mailing Address: 1120 EOt-Sk ROANN - a e_ }- 4 r2M, 94Ctory � t1, Nl'N 42� tity State Fax Number: CISZ I RS4- 4309 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg'4) for Plumbing and Gas Piping (pg 5)) State Contact Person: Mitre PintltipS Day Telephone: (o14- I54S-11S'Sb E -Mail Address:riVAillr pS @V /Ny.0 nriSh4rr ft_ 4Orn Fax Number: (olN IS4S - 'LSSS Company Name:SWQ1rY1gW.V.. &7 Y MQ Pr ■t 1 . Mailing Address: 61.441 Fri .44n 1r* tirt eryN.A Weq CV Me -, ifN yam. \ City State Day Telephone: OA 1$4S• 4ts' O Fax Number: G14 ig4-5 - 4 S Zip Zip Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Expiration Date: ARCHITECT OF RECORD —All plans must be wet stamped by Architect of Record MailingAddress:(o1 .et'n, 5 ►hit ' • W{4.SireSY'Ae., Or 430S1 City State Zip ENGINEER OF RECORD - All tans must be wet stamped by En neer of Record Zip Page 1 of 6 Valuation of Project (contractor's bid price: $ t�Z.� Bung Valuation: $ Scope of Work (please provide detailed information): Linke rivc cen r & oq extcktrci to _koa\ - kart ` u'e- yr vilt rPnkex &,c Nrek. texvij- k .. ORJJ P Will there be new rack storage? ® Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below iS Floor 2 Floor .............................. ............................ .............................. ............................ ............................. Floor Floors thru Basement Accessory Structure* Attached Gauge Detached Garage Attached Carport . Detached Carport Covered Deck Uncovered Dec 1(o, q 'i5 Interior Remodel I4), GI'7 S Addition to Existing Structure Type of Construction per . Type of Occupancy per IBC! M PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? . ❑ Yes ■ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ■ Sprinklers l Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes • No If `yes ; attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Wpplicationsworms- Applications On line n -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PUBLIC WORKS PERMIT I1j RMATION — 206 -433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards Q:WpplieetionsWorms- Applications On line13-2006 • Permit Application.doc Revised: 9 -2006 bh Call before you Dig: 1- 800 -424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Highline ❑ ...ValVue ❑ .. Renton ❑...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water " ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑...Deduct Water Meter Size ❑ ...Sewer Main Extension Public Private _ ❑ ...Water Main Extension Public _ Private FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: ' Qty Boiler /Compressor: Qty BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser % 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 3 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater 1 Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM eb Incinerator — Comm/Ind I 1r1L` l.11t • i li1.11111 it \1' i� 11 i MECHANICAL CONTRACTOR INFORMATION Company Name: 'j'. R. t'. Mailing Address: Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 7av ovv Scope of Work (please provide detailed information): NAtJ c txc au,dr ncsv rie k o - S k - c r2 roe)k top :. • * tom_ _ _■ '. ! . & • u •I'.• a... . - . .,'-. IL 41 IS NPtA) Airv.VYAtf , \o- eithoa k �iu�} = er n , new t x v - hea - e r. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New _II Replacement .... ❑ Indicate type of mechanical work being installed and the quantity below: City State Zip Fuel Type: Electric ® Gas Other: Q :Wpplications\Forms- Applications On linel3 -2006 - Permit Application.doc Revised: 9 -2006 bb Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Z Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 2. Sinks a• Dental unit, cus • idor Shower, sin . le head trap Urinals 1 Dishwasher, domestic, with independent drain Lavatory Z Water Closet 3 Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent , medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPINJERMIT INFORMATION - 206 -43 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: T. 6 . D. Mailing Address: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:V+pplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 2.6 t aut) Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): IJe. /" nrtJv rczX C rk . 1: r" AO ijji i ti 1n2n re T. het,.. (/Jaktr `(.QrA aN ■k 1:V1e Ci\ c X% - ker - �f,vner . �M�S�n 4 \Y e.\� t .fir �'ti^a1 t* Pr uix e.. ve * k'c c'� ,C M co , c OS . Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Page 5 of 6 PERMIT APPLICATION NOT Applicable to all permits in this api ation Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO ' : ZE i AGENT: Signature: Print Name: rn v Mailing Address: IlZO E,a.S} gAt1+1 Skce ek- A'LI‘, g4acoMi t . 1AN S9' City State Zip Date Application Accepted: Q: Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date Application Expires: Day Telephone: SCE 1 S4-4 -OR z. Date: 311e 107 Staff Initials: Page 6 of 6 Parcel No.: 2623049081 Permit Number: M07 -049 Address: 17100 SOUTHCENTER PY TUICW Status: APPROVED Suite No: Applied Date: 03/14/2007 Applicant: DSW SHOES Issue Date: Receipt No.: R07 -01675 Payment Amount: $165.22 Initials: JEM Payment Date: 08/13/2007 08:33 AM User ID: 1165 Balance: $0.00 Payee: TNT MECHANICAL, LLC Payment Check 4095 165.22 TRANSACTION LIST: Type Method Description Amount ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 165.22 Total: $165.22 1439 08/13 x716 TOTAL 165.22 doc: Receiot -06 Printed: 08 -13 -2007 Doc: RECSETS -06 RECEIPT NO: R07 -00358 User ID: 1165 Payee: ELDER -JONES SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City bi Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us D07 -084 2,727.70 M07 -049 f 150.46 PG07 -063 49.50 TOTAL: 2,927.66 Payment Check 48382 SET RECEIPT TOTAL: Initials: JEM Payment Date: 03/14/2007 Total Payment: 2,927.66 SET ID: S000000706 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount 2,927.66 2,927.66 Account Code Current Pmts 000/345.830 2,927.66 TOTAL: 2,927.66 Project: /, , J ction: Ty of Inspection: � -- Addr Date Called: Special Instructions: le Wanted: .r. /� s n. Requester: Phone No: 2- 3 » -, 'S INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: /(i // 4 , 7 - 7 1 6- ' S C _,/ri r/Y7 1 4% /s 47 1 )-7 dr-t<1 / &7 'Inspector: Approved per applicable codes. Corrections required prior to approval. etrk I Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: / (� 4 Type ofln►�� /12,3 Addre /?/2 ^ /e,, Date Called: /%` Special Instructions: a Wanted 7 a.m. -7'3-07 ' Requeste _ Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Aet 0. b f ! ,. 206)431 -367 COMMENTS: Inspector: l ✓ Date , Approved per applicable codes. El Corrections required prior to approval. $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' 80% RTU -1 LENNOX LGAl20H 240000 4000 ECONOMIZE: 240000.00 192000.00 RTU -2 LENNOX LGAl20E 240000 4000 ECONOMIZE: 240000.00 192000.00 80% RTU -3 LENNOX LGAl2OH 240000 4000 ECONOMIZE: 240000.00 192000.00 80% RTU -4 LENNOX LGAl2011 240000 4000 ECONOMIZE: 240000.00 192000.00 80% RTU -5 LENNOX LGA0488 125000 1600 ECONOMIZE: 125000.00 100000.00 80% RTU -6 LENNOX LGA048H 78000 1200 ECONOMIZE 78000.00 62400.00 80% RTU -7 LENNOX LGA048H 78000 1025 ECONOMIZE: 78000.00 62400.00 80% RTU -8 LENNOX LGA048H 78000 1200 ECONOMIZE: 78000.00 62400.00 80% UH -1 LENNOX LF24-100S 100000 1900 100000.00 80500.00 80.50% AIR C. MARS 72C 27297 3400 27297 21837.00 80% Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location RTU -1 LENNOX LGAl2011 120000 4000 1000 MIN 11 EER icant Name: ROOF RTU -2 LENNOX LGAl2011 120000 4000 1000 MIN 11 EER 614 -545 -4550 ROOF RTU -3 LENNOX LGAl20H 120000 4000 1000 MIN 11 EER ROOF RTU -4 LENNOX LGAl2011 120000 4000 1000 MIN 11 EER ROOF RTU -5 LENNOX LGA048H 48000 1600 350 MIN 10.7 EER ROOF RTU -6 LENNOX LGA036H 36000 1200 200 MIN 10.6 EER ROOF RTU -7 LENNOX LGA036H 36000 1025 250 MIN 10.6 EER ROOF RTU -B LENNOX LGA036H 36000 1200 200 MIN 10.6 EER ROOF Project Info ntR+ rot M Project Address DSW Sh Date 3/6/2007 Southcenter Square For Building Dept. Use Tukwila, WA98188 EVIEWED FOR COMPLIANCE A R?9?merdiCn icant Name: Shramshock Engineering, Inc. h Applicant 6130 8. Sunbury Rd., Westerville, Ohio 43 1 CODE Applicant Phdne' 614 -545 -4550 • 2004 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. iv Indudes Plans The I-IVAC system consists of multiple package cooling rooftop units supplying heating and cooli building. Drawings must contain notes requireing compliance with commissioning Revised May 2005 APR -- 4 2007 gas heating and dx g air throughout t Tuk a e81416DINGicININION Compliance Option 0 Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Fan Equipment Schedule Equip. ID EF -1 Brand Name' LOREN COOK Model No. SQN -B -80 CFM 450 SP' 0.50 HP/BHP 0.25 Flow Control cv Location of Service RESTROOM Gl? /ED M 01, Dio4 MAR 1 4 2007 _ PERMITCENTER 1 / If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ✓ Constant vol? ✓ Air cooled? ✓ Packaged sys? 0 <20,000 Btuh? Split system? Economizer included? ✓ If Heating Only: ❑ <5000 cfm? <70% outside air? ■ • • • Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only Reference Section 1421 J otal Ca . wo economize <240,000 Btuh or 10 %? Heating /Cooling or Cooling Only Simple System Allowed (section 1420) Reference ` Section 1423 Use Complex Systems (section 1430) 1 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. open Motors - Closed Motors 3,600 1 1,800 1 1,200 3,600 1 1,800 1 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 924 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 • 2004 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location RTU -1 RTU - RTU -3 RTU -4 RTU -5 RTU -6 RTU -7 RTU -8 UH -1 Synchronous Speed (RPM) HP 1.0 1.5 20 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 3 3 3 3 HP 1- 1/2 3/4 3/4 3/4 1 /10 DSW Shoes Type (open/closed) open open open open open open Minimum Nominal Full-Load Efficienc Description of Application or Use ROOFTOP UNIT, EXCEPTION t2 ROOFTOP UNIT, EXCEPTION 42 ROOFTOP UNIT, EXCEPTION /2 ROOFTOP UNIT, EXCEPTION 42 ROOFTOP UNIT, EXCEPTION #2 ROOFTOP UNIT, EXCEPTION t2 ROOFTOP UNIT, EXCEPTION •2 ROOFTOP UNIT, EXCEPTION *2 UNIT HEATER, EXCEPTION A2 Date For Building Department Use Synch. Speed 1800 1800 1800 1800 1800 1800 1800 1800 1800 3/6/2007 Revised May 2005 Min.Nom. Full Toad Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi-speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14 -1 or 14-2) . 3. Motors that are an integral part (i.e. not easily removed and replaced of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (Le. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. ' 171ia711%I l l ►T 1 ■ Mtai a 111 l iE of [ U r-i / W"11.3 .1, r-1 w --.. -..a ma.. .A m l 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 Project Address DSW Shoes 'Date 3/6/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability Code (yes, no, n.a.) Section Component 'Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 85.1 yes 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 86.1 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans 81.1 yes 1412.2 Deadband control Indicate 5 degree deadband minimum 86.1 n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 Jiff. day types s5.1 yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage E6.1 n.a. 1412.4.2 Optimum Start Indicate optimum start controls n . a . 1412.5 Heat pump control Indicate microprocessor on thermostat schedule yes 1412.6 Combustion htg. Indicate modulating or staged control H6.1 yes 1412.7 Balancing Indicate balancing features on plans 81.1. n.a. 1422 Thermostat Interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule 85.1 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule E6.1 n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg bad & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling 86.1 DAL. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary 86.1 yes 1414.2 Duct insulation Indicate R -value of insulation on duct 56.1 yes 1415.1 Piping insulation Indicate R -value of insulation on piping 86.1 1416 Completion Requirements yes 1416.1&2 Drawings & Manuals Indicate requirement for record drawings and operation dots. 56.1 yes 1416.3.2 Air Balancing Indicate air system balance requirements 56.1 n.a. 1416.3.3 Hydronic Balancing Indicate hydronic system balance requirements yes 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report 86.1 yes 1424 Separate air sys. Indicate separate systems on plans 56.1 yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 86.1 SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water Mg. yes 1441 Elec. water heater Indicate R -10 insulation under tank P6.1 yes 1442 Shut -off controls Indicate automatic shut -off P5.1 yes 1443 Pipe Insulation Indicate R -value of insulation on piping P6.1 n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover rcled for any question, prow ae explanation: f 1' lli-ie7l1% 1116VS :1MalblllslMrrll1727l1�a7s\11 2004 Washington State Nonresidential Energy Code Compliance Forms Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it Includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with Input ratings > 225,000 Btu/h (65 kW) shall also have an intermittent ignition or interrupted device (HD), and have either mechanical draft (Including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225.000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In comb nation space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equlpmsn : Packaged electric equipment providing both heating and cooling with a otal cooling capacity greater than 20,000 Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412A Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Dsadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if In the proposed building energy analysis, heating and cooling thermostat setpolnts are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories In height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.6 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor oontrois that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall Indicate when supplemental heating Is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. ('11 arI ■111G071 Revised May 2005 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45"F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data Including model number, flow rate, capacity. entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse Joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse Joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements Include Insulation installation, moisture control, air leakage. and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with Tess than 2,800 efm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are Isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1416 Piping Systems 1416.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Excsptlon: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) EF CAE < 50 pal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 f 1' lli-ie7l1% 1116VS :1MalblllslMrrll1727l1�a7s\11 2004 Washington State Nonresidential Energy Code Compliance Forms Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it Includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with Input ratings > 225,000 Btu/h (65 kW) shall also have an intermittent ignition or interrupted device (HD), and have either mechanical draft (Including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225.000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In comb nation space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equlpmsn : Packaged electric equipment providing both heating and cooling with a otal cooling capacity greater than 20,000 Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412A Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Dsadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if In the proposed building energy analysis, heating and cooling thermostat setpolnts are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories In height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.6 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor oontrois that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall Indicate when supplemental heating Is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. ('11 arI ■111G071 Revised May 2005 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45"F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data Including model number, flow rate, capacity. entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse Joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse Joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements Include Insulation installation, moisture control, air leakage. and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with Tess than 2,800 efm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are Isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1416 Piping Systems 1416.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Excsptlon: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) TNTMEL*011 K7 Scott Harrison President City of Tukwila Deportment of Community Development 6300 Southcenter Blvd. Suite 100 Tukwila, WA 98188 206 -431 -3670 fax- 206 - 431 -3665 To Whom It May Concern, Thank you for taking time to discuss the permit #M07 -049 with me this afternoon. As we discussed. 1. The permit for the DSW shoes rooftop equipment and ductwork drops was already pulled by b -15 Mechanical. 2. The above permit application #M07 -049 was applied for by a permit expeditor hired by the tenant prior to our involvement. This permit expeditor obviously did not know the extent of the remaining scope of work left on the job after the work by D -15 mechanical. 3. We have been hired to complete the remaining scope of work on the Mechanical drawings in your possession. This work involves ducting the three units which get ductwork beyond the drops. It also includes running condensate lines in pvc, and installing a unit heater. The total contract for this work is only $13,500.00 4. Our permit fee's for our scope should be much Tess than the $631,84 which shows a value of $75,000 which was the entire scope of work including the work 0-15 mechanical had already permitted. Thank you for considering these facts and re- evaluating the balance owed on permit #M07 -049. 22833 Bothell - Everett Hwy. HEATING AND AIR CONDITIONING Everett • Seattle • Tacoma • Lacey • Yakima PMB *1164 • Bothell, WA. 98021 • Ph: (206) 788.2293 Fax: (425) 806 -9952 Email: ecatthetntmechanlcal.com 07 -31 -2007 SARAH NIELSEN 1120 E 80ST#211 BLOOMINGTON MN 55420 RE: Permit Application No. M07 -049 17100 SOUTHCENTER PY TUKW Dear Permit Applicant: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current permit application files, it appears that your permit application applied for on 03/14/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 09/10/2007 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 09/10/2007. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall t Technician Permit File No. M07 -049 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M07 -049 DATE: 03 -14 -07 PROJECT NAME: DSW SHOES SITE ADDRESS: 17100 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bui Ong Division l§j Complete Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY' PLAN REVIEW /ROUTING SLIP fII AWC 3•IS Fire Prevention Xj Structural Incomplete ❑ DATE: Planning Division No further Review Required DATE: n ❑ Permit Coordinator C DUE DATE: 03-15-07 Not Applicable ❑ n DUE DATE: 04-12-07 Approved with Conditions❑V Not Approved (attach comments) E Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License TNTMEL *011K7 Licensee Name T -N -T MECHANICAL LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 601950443 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 22833 BOTHELL - EVERETT HWY 1164 Address 2 City BOTHELL County SNOHOMISH State WA Zip 98021 Phone 4254864327 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/27/1999 Expiration Date 5/27/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HARRISON, SCOTT PARTNER/MEMBER 01/01/1980 Bond Amount LIBSACK, JERI PARTNER/MEMBER 01/01/1980 850223C Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #3 DEVELOPERS SURETY & INDEM CO 850223C 05/27/2002 Until Cancelled $12,000.00 03/18/2000 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. http 11 K7 08/13/2007 r 1 SPIN -IN FITTING W/ BAL DPR. TYP. • _ �l e'4� 1i 2�Q) SD -5 EF -1 I� � 210 ii � /t - -"I . mom - EM. ®= 1 �� I/r izim l {l1i ►�-r P I 6'. (r 12x10' DOWN •m � � ,, 1� 4 mu 1 • `li� ■ - V- 1 145x10' O I-1/2" 14'x12' 10 1 _ t _ 12'x10' DOWN 14'x8' 8'm SD- u 0 r 0 225 IN STRUCTURE, TY 8'm! 0 1 1 -1/2' TO RTU -3M 28'x18' RA 28'x18' RA Co • 1 -1/2' 1 -1/2' ER -I /50 -4 1 00 -( 5 I -I/2' 28'x18' SA BAL. DPR. TYP. 5D -I 4000 RTU -3 1580 IBS. 10'x10' 700 RTU -7 LBS. RR -1 150 FLEX CONNECTION TYP. ( 12 ) IN STRUCTURE, TYP 1' D I -1/2' 0 0 TO RTU -5 FOCAL J 1200 RTU -e 700 LBS. HVAC PLAN Lo =1'-O' 1 -1/2' MARS AIR CURTAIN, mom. * 1 WITH 804 ELECTR HEAT. IDE MICRO SWITCH MIT AUTOMATIC ON/OFF OPERATION bi13•IEN DOORS OPEN. 206 VOLT 3 PHASE WITH (2) 1/2 HP MOTORS. IN STRUCTURE, TYP.-N _ T TO RTU -5 ( q ) T. ! TO RTU -6 • EX. SPRINKLER ROOM RR -3 r Pernik • Pin IWvtew appals! Is subject b avers and dniskrat. /r.'Ip1lalydl cf • • - . ... d00/!1lflb QO!!!< z the vb;atsal, d . • • • • • node or a�dil>arlmsU lIOI" R+eaett of apprond - I • and condlkos t I,dalowledged: es Clly of DIVISION BUILDING EX. ELECTRICAL ROOM SR -6 28'x14'_25 ASR -6 0 ;% J I X250 BAL. DPR. I1 iJI ;i: 1 O /r 28'x14' SR- 11111 250 `t` • • -5R -6 200 700 5R -6 SEPARATE PERMIT REQUIRED FOR: I E7ecel¢1 0 Methanol J_ 0 Medaarlic2 0 Qs P:; : Gty cf TEA : : : : BLIILDI ,; Di 1sIo PhraSIONS •J be made to th o yd....� :: >t.-i thout prior apprcr a! c: ... :,.;29 Gtr::' 31. • ALL HVAC WORK SHALL COMPLY WITH APPLICABLE SECTIONS OF THE MECHANICAL CODE, THE BUILDING CODE, AND THE APPLICABLE ENERGY CODE. ALL DUCTWORK, DUCT MATERIAL AND VOLUME DAMPERS MUST COMPLY AND BE INSTALLED WITH THE LATEST EDITION OF SMACNA. - COORDINATE AND SCHEDULE ALL WORK WITH OTHER TRADES AND GENERAL CONTRACTOR. • ALL MECHANICAL INSTALLATION SHALL COMPLY WITH LOCAL AND STATE CODES. • DUCT DIMENSIONS ARE NOMINAL CLEAR INSIDE DIMENSIONS. 9. ALL DUCTWORK MUST BE INSTALLED AS HIGH AS POSSIBLE. 10. COORDINATE EXACT LOCATION OF ALL AIR DEVICES WITH LIGHTING PLAN. 11. BALANCE SYSTEMS TO CFM'S NOTED ON PLANS. 12. MECHANICAL CONTRACTOR SHALL VISIT 406 SITE AND BE FAMILIAR WITH LANDLORD'S REQUIREMENTS. NO ALLOWANCE WILL BE MADE FOR EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND /OR FAILURE TO PREDETERMINE ALL EXISTING CONDITIONS IMPOSED BY THE LANDLORD OR OTHER AUTHORITIES. 13. SPIN -IN FITTINGS WITH MANUAL BALANCING DAMPER TO BE USED FOR ALL ROUND BRANCH TAPS ABOVE ACCESSIBLE LAY -IN CEILINGS. SPIN -IN FITTINGS WITHOUT MANUAL BALANCING DAMPERS TO BE USED FOR ALL ROUND BRANCH TAPS ABOVE INACCESSIBLE DRYWALL CEILINGS WITH BALANCING REQUIRED WITHIN 2 FT. OF DIFFUSER WITH PLASTER FRAME. 14. 15. 16. THE HVAC CONTRACTOR SHALL PROVIDE TENANT WITH AS -BUILT DRAWINGS, ALL EQUIPMENT SHOP DRAWINGS, INFORMATION ON THERMOSTATS, CONTROL WIRING DIAGRAMS AND OTHER PERTINENT INFORMATION AT COMPLETION OF PROJECT. 17. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR LOCATION OF CEILING AIR DEVICES. 18. ALL ROOFING WORK TO BE COMPLETED BY LANDLORD'S ROOFING CONTRACTOR. 19. ANY EXISTING WALL/FLOOR OR CEILING SURFACE THAT I5 DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED TO MATCH NEW AND /OR EXISTING CONDITIONS. 20. TH15 CONTRACTOR TO SUPPLY ROOF CURBS. LANDLORD INSTALL ROOF CURBS. GENERAL NOTES ALL RECTANGULAR DUCTWORK SHALL BE INTERNALLY LINED WITH A MINIMUM OF I' DUCT LINER. ALL RECTANGULAR DUCTWORK IN AN UNCONDITIONED SPACE SHALL HAVE A TOTAL INSTALLED INSULATION R -VALUE OF 5. ALL ROUND DUCTS ARE TO BE WRAPPED WITH 2' OF INSULATION TO HAVE A MINIMUM INSTALLED R -VALUE OF 5. WHERE CONCEALED ABOVE CEILINGS TO MEET ENERGY CODE. EXHAUST DUCTWORK IS NOT TO BE LINED OR WRAPPED. ALL THERMOSTAT LOCATIONS TO BE FIELD VERIFIED AND COORDINATED WITH GENERAL. CONTRACTOR AND ARCHITECT. DUCT LAYOUTS ARE SCHEMATIC. FIELD COORDINATE ALL DUCT RUNS. (PRIOR TO DUCT FABRICATION) NO EXTRAS SHALL OE AWARDED FOR DUCT REVISIONS CAUSED BY LACK OF COORDINATION. FLEX CONNECTIONS TO DIFFUSERS ARE INSULATED FLEX WITH A MAXIMUM LENGTH OF 5' -O' AND SHALL HAVE A MINIMUM R VALUE OF 5. THE HVAC CONTRACTOR I5 RESPONSIBLE FOR COORDINATING BOX -OUT LOCATIONS FOR ALL DRYWALL MOUNTED AIR DEVICES P11114 GENERAL CONTRACTOR AND CEILING FRAMING. CODED NOTES SUPPLY AND RETURN AIR DUCT CONNECTIONS TO ROOFTOP UNITS SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING WITH FLEXIBLE DUCT CONNECTIONS AT UNIT. TRANSITION AS REQUIRED TO DUCT SIZE SHOWN. 1 -1/2' CONDENSATE DRAIN DOWN TO MOP SINK. COORDINATE SUPPLY AND RETURN AIR DUCT PENETRATIONS WITH ARCHITECT AND BUILDING STRUCTURE. ROUTE 4' TYPE 'B' VENT UP THRU ROOF. TERMINATE WITH ROOF CAP, STORM COLLAR, AND FLASHING. COORDINATE PENETRATION WITH ARCHITECT AND BUILDING STRUCTURE. SEAL. WATER TIGHT. HVAC CONTRACTOR TO PROVIDE AND INSTALL SMOKE DETECTORS IN RETURN AIR DUCTS. DETECTORS SHALL BE SYSTEM SENSOR AC DC P -DH 100 WITH REMOTE TEST SWITCH. LOCATE TEST SWITCH ADJACENT TO UNIT THERMOSTAT. CONNECT TO RTU SHUT DOWN CIRCUIT. POWER TO DETECTOR AND CONNECTION TO ALARM SYSTEM WILL BE BY TENANT'S ALARM SYSTEM CONTRACTOR UNDER SEPARATE CONTRACT WITH TENANT. COORDINATE WITH THE ELECTRICAL CONTRACTOR. THERMOSTAT TO BE HONEYWELL UT7300 WI c rl ON/OFF /AUTO. THERMOSTAT TO BE I`IOJNTED ON BACK SIDE Or COLUMN WITH PLASTIC LOCKING COVER. MOUNT AT 60'_ ROUTE CONDENSATE DRAIN BELOW ROOF. SEE ROOF TOP UNIT DETAIL 'A' ON SHEET 16.1 AND CONDENSATE DRAIN DETAIL 'D' ON SHEET H5.1_ INSTALL CONDENSATE DRAIN FROM RTU AS REQUIRED. MINIMUM DRAIN SIZE TO BE 1'- CONDENSATE DRAIN TO BE TRAPPED WITH A TRAP DEPTH OF 1.5 X UNITS TOTAL STATIC PRESSURE (MINIMUM 5' DEEP). PIPING SHALL BE W RESISTANT PVC. PVC JOINTS SHALL BE CHEMICALLY WELDED. 10'jclO' EXHAUST DUCT UP TO ROOF CAP. SEAL ROOF PENETRATION WATER TIGHT. TI4M1OSTAT TO BE 1.4NEfWELL =T7300 WITH ON/OFF /AUTO. THERMOSTAT TO BE MOUNTED ON WALL WITH PLASTIC LOCKING COVER. r1OUNT AT 48'.COORD1NATE WITH STORE FINISHES. THERMOSTAT TO BE I•;ONEYWELL •=T7300 WITH ON/OFF /AUTO. THERMOSTAT TO BE rOUN T ED ON ON ALL WITH PLASTIC LOCKING,. CO /E2. MEAT AT 48'. M EC..IJA !CAL CONTRACTOR SHALL PROVIDE AND INSTALL ROOFTOP UNITS ON ROOF WITH PROPER SERVICE CLEARANCE AREA AS RECOMMENDED BY PIANVFACTURER AND AS SI-IDAN ON PLANS. CONTRACTOR SHALL COORDINATE MTH STRUCTURE. PROVIDE ROOFTOP UNITS WITH 3 SETS OF FILTERS. CHAtvGE FILTER AFTER FINAL CLEANGNG AND AGAIN PRIOR TO AIR BALANCE. CONTRACTOR TL''ST VERIFY mOPEEL NXIMBEERS AND ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION. SEE ROOFTOP ;-' /AC UNIT SCHEDULE ON SHEET I;5.1 FOR ADDITIONAL IWORMATION. FuRN!5N AND INiSTALL COOK EXHAUST FAN (;271/_, iPill., 604Z) CG.` PLETE pritTl+ INTEGRAL BACKDRAFT DAMPER. SEE EXP1AUST FAN SCHEDULE ON 5044E-ET 1-5.1 FOR ADDITIONAL INFrORi ATIGN. TRANSITION AS RELIiREEa SUPPORT FROM STRUCTURE LisTH VIBRATION ISOLATION. PROVIDE`. A.NO INSTALL TURN:N;G VANES IN DUCT TEE AT WE BOTTOM GF a :,c S.?PPY DUCT &RCP. BLANK OF :H--5 STE OF THE D:=F15ER 50 TV:+T WE OT.•:ER TREE SIDES Ioi;;.L BL '4 AIR TOWARD WE FRONT OF THE STORE_ RECE.IVED CT) UN- T I?..ATER FROM r 1:-+E STRI.ICT1;RE PER i r CIT OFT ij( J' I A :'JI.V..P�L.R .T`'S INS T R:�CTIO�tS. ! i ez� I 4 7 PERMIT Ct±TFc MD I 1 O 1 0 E p 1 0 H1.1 I ER ecr•as •.F! o 6 19WCASi6 71 et MUM 1pItEMEas E RamKIR w► wascrocrEcraisseccosavguncam ow MD NI OSOSni UREA sirsCLOa=O. • WE iTZIOIMATE MIL sat imam an soa•lemolelt uaE+s wGEE sa ammarsom. a7A1 # 07108 DRAWING NUMBEIt I 1 AIR DEVICE SCHEDULE UNIT NO. TYPE BORDER .lYM -I THROW - 0 AVM-6 MOTOR MATERIAL - � 2 I 133.1.6 -- wnNlwnler DI1ra'v'1d ACCESSORY DAMPER A W 0121' '1`dn03 C? -- - . 213c1WYC 32115 SYMBOL KEY - FIRST LETTER' S- SUPPLY R- RETURN E- EXHAUST SECOND LETTER• D--DIFFUSER R- REGISTER G- GRILLE KEY TAG `b...212=1 CFM boo • TAG 2136nuA r 2131510321 3111210 2136n4. IC ?d'v'3N11 C1w ODYAWIS NI -.1.V MODEL NO. 10 SIZE REMARKS FADE NECK SD -I 97.2 11.0 1750 2aa 2 125/192 156/240 2' 57 70 1 4 5 6 O © © 000 4 RTU -2 LENNOX LGA 21 OH 4,000 LENNOX RTD11 -135 -- -- LENNOX 5D -2 1750 2a8 3 1 125/192 % 2' 57 70 1 4 5 6 7 8 © ©00000 RTU -3 GA1 L220N 4,000 0.8' 120 97.2 LENNOX RTDq -65 -- -- LENNOX SD -3 125/192 156/240 2' 57 70 O 0 4 5 6 ©000 RTU -4 LENNOX 4,000 O.8' 120 97.2 11.0 -- 3 1750 TMS 24/24 8'0 O O O 5D -4 57 70 1 q 5 6 0 ..<><><> 0 * RTU -5 L EN N OX 11 1,600 350 0.8' 48.0 36.4 10.7 1.5 1750 ` ' _ 2 73.6/100 TMS 24/ 6'� 3 O..* SD -5 RTU -6 LENNOX 4GA036H 1 ,200 200 O 36 25 .9 10.6 3/4 1750 208 3 1 62.4 78 2' 21 TMS 12/12 B'0 30 O O 5R -6 250 ' 36 25.9 10.6 0---.- 1750 2° 08 3 1 62.4 78 2' 21 30 1 6 0 © ©0000 RTU -8 300 RL 14/8 12/6 0 O RR -I 25.9 10.6 3/4 1750 208 3 0 62.4 78 2' 21 30 350 RL 24/12 22/10 0006 RR -2 350 RL 24/12 8'O OOOO RR -3 350 RL 28/14 28/14 60 ER -1 J 360 RL 12/12 6'm 30005 O O ER -2 350 RL 12/12 64 3000 4). ROOFTOP HVAC UNIT SCHEDULE UNIT NO. MFR., MODEL NO. CFM OA. CFM EXT. S.P. COOLING DATA MOTOR HEATING DATA FILTERS MCA MOCP • REMARKS TOTAL COOLING MBH SENSIBLE COOLING MBN EFF. MR 1.4An5 HP R.P.M. VOLTS PHASE STAGES HEAT OUTPUT MBH HEAT INPUT _ MBH RTU -1 L . ' 1 4 0 X 11 I 4,000 1800 0.8' 120 97.2 11.0 1750 2aa 2 125/192 156/240 2' 57 70 1 4 5 6 O © © 000 4 RTU -2 LENNOX LGA 21 OH 4,000 0.8' 120 97.2 I1.0 3 1750 2a8 3 2 125/192 156/240 2' 57 70 1 4 5 6 7 8 © ©00000 RTU -3 GA1 L220N 4,000 0.8' 120 97.2 11.0 3 1150 2408 3 2 125/192 156/240 2' 57 70 O 0 4 5 6 ©000 RTU -4 LENNOX 4,000 O.8' 120 97.2 11.0 -- 3 1750 24013 3 2 125/192 156/240 2' 57 70 1 q 5 6 0 ..<><><> 0 * RTU -5 L EN N OX 11 1,600 350 0.8' 48.0 36.4 10.7 1.5 1750 3 2 73.6/100 92/125 2' 27 40 1 6 IV O © © O •• RTU -6 LENNOX 4GA036H 1 ,200 200 O 36 25 .9 10.6 3/4 1750 208 3 1 62.4 78 2' 21 30 1 6 0 © ©0 O 0 RTU -7 LENNOX LG1 03614 1,025 250 0 36 25.9 10.6 - 3/4 1750 2° 08 3 1 62.4 78 2' 21 30 1 6 0 © ©0000 RTU -8 LENNOX LGA036H 1, 200 200 0.8' 36 25.9 10.6 3/4 1750 208 3 1 62.4 78 2' 21 30 I 6 4 4 0 0 0 UNIT HEATER SCHEDULE UNIT NO. MFR.. MODEL NO. PROJECTION LIL CFM MBH INPUT MBH OUTPUT EA.T. 'F L.A.T. •F MOTOR REMARKS H_P. WATTS R.P.M. VOLTS PHASE UN -1 LENNOX 1F24 -1OOS HORIZONTAL PROP. 1900 100 80.5 60 T WOMEN/MEN 1/10 -- 1800 120 I EXHAUST FAN SCHEDULE UNIT NO. MFR..Q MODEL NO. TYPE CFM a t6. vi WHEEL R.P.M. MOTOR SERVING LOCATION REMARKS H_P_ -r-r5• RPM VOLTS PHASE EF -1 LORE BC GENT. INLINE EXH_ 450 0.5 1585 1/4 -- 1750 120 I T WOMEN/MEN AB. CLG. <><> © O t • CLAMP 12' MIN. FLUE 3/6' ROILED HANGS? RODS_ ATTACH TO STRUCTURE W/ BEAM CLASS TNR5 T AT MT IN C.ONDAT BOX GN 3/4' RIGID CO 0U'T 7 -6' AFF FLASHING ROOF STEEL METAL STRAP ATTACH SUPPORTS TO THE TOP CI4ORD OF ROOF JOISTS r UNIT HEATER DETAIL s 1 SCALE. NTS • BASED ON TITUS UNLESS OTHERWISE NOTED. UNLESS SHOWN OTHERWISE ON DWGS. VERIFY MTG. ARRANGEMENT W/ CLG TYPE (LAT -IN, SURFACE MOUNT, ETC.) O FURNISH SQUARE TO ROUND NECK TRANSITION PIECE WHERE REQUIRED. 4> 0 GAS LINES BY P.G. GAS FIRED i;N :T 14EATER 8111. AT 9' -O' A F_F GAS COCK BY P.C. • 1 -1/2' DEEP SEAL `P' -TRAP SOLDER ALL ROUND FLASH PE? ETRA T ION 11- ROUGH ROOF ROOFING ROOF L SULATICt - CONDENSATE DRAIN P -TRAP BELOW ROOF DETAIL SCALE: NTS 6' MN. DIRT LEG ROOF STRUCTURE 22 GAUGE SLEEVE 2' TYPICAL ALL AROUND B DUCT THROUGH ROOF DETAIL SCALE:NTS H5.1 • DAMPERS TO BE OPPOSED BLADE AIR DEVICE TO DAVE STANDARD OFF -WHITE FINISH PROVIDE WITH DRYWALL TRIM RING. 1' COND DRAIN FROM AHU 1 -1/2' 1-111B 6' ABV ROOF I -1/2' COND DRAIN TO APPROVED LOCATION ALL WEATHER VENT CAP STORM COLLAR 8' mNIIVi DPAUST DUCT i iINIM 3 FEET • ROOF ROOF CURB 747•7•7•74 ■711171•7•71E4f4Z ►37474•- •_•_•_• .1.7 41m•_• •_•_ .. 7 7 . 7 ■ ..... 7 V VII PROVIDE SECURITY BARS IN ALL PENETRATIONS rrPeCAL ALL FOUR SIDES. I 1 1 I I I I I I I 1 1 I I I I I I I I I I 1 I I I 1 I I I 1 1 I I 1 I I I 1 I I I I I I I I 1 I I 1 1 I 1 I 1 1 O FURNISH WITH MOTORIZED OUTSIDE AIR DAMPER • PROVIDE ALL UNITS WITH 14' HIGH CURB, FACTORY MOUNTED DISCONNECT, AND FACTORY INSTALLED GFI DUPLEX RECEPTACLE_ LANDLORD TO INSTALL CURBS_ 4 0 PROVIDE WITH POWER EXHAUST(LAPEF 10/15), DIFFERENTIAL SENSIBLE CONTROL ECONOMIZER, CEILING DIFFUSER RTDII -135 WITH SRT TRANSITIONS, AND HONEYWELL 17300 STAT WITH LOCKING COVER. RA DUCT ROOFTOP UNIT SA DUCT DIFFUSER STEP -DOM TYPE WITH ALUMINUM DOUBLE DEFLECTION LOUVERS, )NSULATED DIFFUSER L30X WITH FLANGES, HANGING RINGS, INTERIOR TRANSITIONS AND INTERNALLY SEALED PL'7�.Z1P'.S. rlAX111.119 WEIGHT - 500 LBS A ROOF UNIT DETAIL H 5 . 1 SCALE: NTS • O PROVIDE WITH DISCONNECT SWITCH AND BACKDRAFT DAMPER. O INTERLOCK WITH RTU -7. O DUCT SMOKE DETECTOR FACTORY INSTALLED IN RETURN AIR O EXT. 5.P. DOES NOT INCLUDE COIL, CASING, OR FILTER LOSSES. O PROVIDE WITH INTEGRAL FILTER RACK WITH DISPOSABLE FILTERS, BELT DRIVE INDOOR FANS, HAIL GUARDS, AND A FREEZE STAT. O PROVIDE WITH SINGLE POINT POWER CONNECTION WITH UNIT MOUNTED DISCONNECT. INSTAI.l. 3'x3' STEEL ANGLE BRACING AT UNDERSIDE OF ROOF DECK, UNDER ALL SIDES OF ROOF CURB. ROUTE CONDINSA i E DRAIN TI;.ROUGN ROOF TO HUB DRAIN ADJACENT TO EACH RTU AND ROUTE TO MOP SINK, AS ALLONABLE. PITC&1 AS REOfIRED FOR PROPER DRAINAGE. DO : T ROUTE CONiDE7i5ATE LINES ABOVE ROOF_ N TE; ALL G 4.14- TIC 5 A1' D SERVACES MST 2.E i.N D T fiE PE.R4ME CU M& D9S CVECT 5v4i:TC •5, BRACKETS, AND CONDUIT MST BE CLEAR OF ALL UNIT PANELS A?4D AIR FLOW. . MANI': G BRACKETS V ST BE TO STRUCTURAL r.E."®ERS OF UNIT. • ROOF O PROVIDE WITH BURGLAR BARS. O PROVIDE WITH BAROMETRIC RELIEF DAMPER, ECONOMIZER, AND HONEYWELL T7300 STAT WITH LOCKING COVER. 1® PROVIDE WITH BAROMETRIC RELIEF DAMPER, ECONOMIZER, CEILING DIFFUSER RTD9 -65 WITH SRT TRANSITIONS AND HONEYWELL T7300 STAT WITH LOCKING COVER. $ PROVIDE PR -12 ROOF CAP OI� CURB . --7 4 MAINTAIN 10' -0' FROM ROOF GAP T " W U*. f 1 .` SYMBOLS & ABBREVIATIONS LEGEND -C- DUCT OFFSET S -.1 SUPPLY DUCT - UP SUPPLY DUCT - DN RA OR E»1. DUCT U? RA OR D04. DUCT DN ELBOW TURNING VANES FIRE DAJIPER (F.D.) 1 1 ----- MANUAL BALANCE DAMPER - -- -�� TRANSITION 1 ' �f IZI 1J THERMOSTAT SENSOR ANNUNCIATOR DUCT SMOKE DETECTOR SUPPLY DIFFUSE R RETURN GRILLE EXHAUST GRILLE SPIN -IN FITTING 4 0 SP :N -IN FITTING IA/ ;'IAN. BAL. DPR. X'' ROuND DUCT AB_ ABOVE A/C AIR C N.D.T!GNi'G AD /.CCCESS COG? AFF_ ABOVE FINISHED FLOG? AIR HANDLING LAM ARCH_ ARCI i T ECT ac BACKCRAFT DPR. 5LD . 13 LE:N s C17 CLE1 G FEET PER r,.M.TE CLG. CEILING A r. rs r rwr. r) APP '1 2001 i City Of Tukwila BUILDING D11fSTON CONT. CONTINUATION CONTR. CONTRACTOR COORD. COORDINATE CUH. CABINET UNIT HEATER DIFF. DIFFUSER DISC. DISCONNECT DN. DOWN DPR. DARER EA_ EACH EC. ELECTRICAL CONTRACTOR EX. EXISTING EXH_ EXHAUST F. DPR. FIRE DAMPER FLEX. FLEXIBLE FLR. FLOOR GC. GENERAL CONTRACTOR MC. HEATING CONTRACTOR 14P. H RSEPa, ER MAX. MAXIS 1 MCA. MAX CIRCIUT AMPACITY MECH. MECHANICAL MFR. MANUFACTURER MIN. r NfMU;i MOCP. MAX OVERCURREEN T s PROTECTION MTD. ."O. 4TED N T S. NOT TO SCALE ` OA. OUTSIDE AIR PC. PLUil3:NG CONTRACTOR RA. RETURN URN MR RTU. ROOFTOP UNIT SA. SUPPLY AIR TV. T1iRN NG VANES TYP. TYPICAL ,BITER HEATER n/ KITH i REGEP:FD CirYOFTUKvi ?LA M01 O PE-: 0 1 v 7 L' 1 9 CN 1 0 W LAMM fat eneEasaINEDLOSPO t aa� A1eEt•Oi0EeIMIS SEAM KaIUDs a.saEwalCo MBE ••Z x••m osaE WL fle **DIN *O11/ 2 a SA!1 407 DRAWING NUMBER: H5.1 1 15510 GENERAL PROVISIONS A. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL A HEATING, VENTILATING AND AIR CONDITIONING SYSTEM, COMPLETE AS INDICATED ON THE DRAWINGS, AS REQUIRED BY CODE AND AS SPECIFIED HEREIN. B. WITHOUT RESTRICTING THE GENERALITY OF THE FIRST STATEMENT, THE WORK TO BE PERFORMED UNDER THIS DIVISION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING: C. D. I) HVAC WORK AS DESCRIBED IN SECTIONS 15510 THROUGH 15980. THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED I5 TO PROVIDE POWER WIRING FOR EACH ITEM OF ELECTRICAL EQUIPMENT AND MAKE FINAL CONNECTION TO MOTORS. ALL FINISH PAINTING IS TO BE PERFORMED BY THE GENERAL CONTRACTOR, EXCEPT AS NOTED ELSEWHERE. THIS CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION ANY PAINTING DEFACED BY HIM AFTER ORIGINAL PAINTING. E. ALL WORK SHALL CONFORM TO CODES, RULES, AND REGULATIONS: I) NATIONAL ELECTRIC CODE. 2) STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, NEPA %OA. 3) CODE FOR SAFETY TO LIFE FROM FIRE IN BUILDINGS AND STRUCTURES, NFPA 101. 4) OCCUPATIONAL SAFETY MD HEALTH ACT (OSHA) AND ALL AMENDMENTS. 5) STATE MECHANICAL. CODE. 6) STATE BUILDING CODE 7) STATE INDUSTRIAL COMMISSION REQUIREMENTS. 8) LOCAL BUILDING CODE REQUIREMENTS. 9) BUILDING INSURING AGENCY REQUIREMENTS. F. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION SHALL BE OBTAINED AT THE PROPER TIME BY AND AT THE EXPENSE OF THIS CONTRACTOR. G. THIS CONTRACTOR SHALL OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES AND PUBLIC AUTHORITY HAVING JURISDICTION AND SHALL OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE ARCHITECT AND SMALL PAY ALL FEES, CHARGES, ASSESSMENTS AND OTHER EXPENSES IN CONNECTION THEREWITH. H. PIPING AND EQUIPMENT LAYOUT 15 SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY STRUCTURAL AND OTHER CONDITIONS. DESIGN OF SYSTEM MAY NOT BE CHANGED. ONLY EXACT LOCATION OF PIPING AND DUCTS MAY BE REVISED TO SUIT CONSTRUCTION CONDITIONS AND AID IN COORDINATION WITH WORK OF OTHER CONTRACTORS. I. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT SHALL BE ORDERED UNTIL REVIEWED BY THE ENGINEER AND/ OR ARCHITECT. J. THE CONTRACTOR SHALL SUBMIT FOR THE ARCHITECT'S REVIEW SIX (6) COMPLETE COPIES OF THE CATALOG DATA AND /OR SHOP DRAWINGS (SEPIAS AT CONTRACTOR'S OPTION) FOR EVERY MANUFACTURED ITEM OF EQUIPMENT AND ALL COMPONENTS TO BE USED IN THE WORK, INCLUDING SPECIFIC PERFORMANCE DATA, MATERIAL DESCRIPTION, RATING, CAPACITY, WORKING PRESSURE, MATERIAL GAUGE OF THICKNESS, BRAND NAME, CATALOG NUMBER AND GENERAL TYPE. THE SUBMISSION SHALL BE COMPILED BY THE CONTRACTOR AND REVIEWED BY TIE ENGINEER BEFORE ANY OF THE EQUIPMENT I5 ORDERED. K. CATALOG DATA FOR EQUIPMENT REVIEWED BY THE ARCHITECT SHALL NOT SUPERSEDE THE ENGINEER'S CONTRACT DOCUMENTS. THE REVIEW OF THE ENGINEER SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS, PROVIDING PROPER CLEARANCE, FABRICATION PROCESS AND COORDINATION WITH OTHER TRADES. L. WHEN SUBMITTED FOR THE ARCHITECT'S REVIEW, SHOP DRAWINGS SHALL BEAR THE CONTRACTOR'S CERTIFICATION THAT HE HAS REVIEWED, CHECKED AND APPROVED THE SHOP DRAWINGS, THAT THEY ARE IN HARMONY WITH THE REQUIREMENTS OF TI4E PROJECT AND WITH THE PROVISIONS OF THE CONTRACT DOCUMENTS AND THAT NE HAS VERIFIED ALL FIELD MEASUREMENTS AND CONSTRUCTION CRITERIA, MATERIALS, CATALOG MR4BERS AND SIMILAR DATA. CONTRACTOR SHALL ALSO CERTIFY THAT THE WORK REPRESENTED BY TIE 5140P DRAWINGS IS RECOMMENDED BY THE CONTRACTOR AND THE CONTRACTOR'S GUARANTEE WILL FULLY APPLY_ ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK 5IALL FIRST EXAMINE THE SITE AND ALL CONDITIONS THEREIN. ALL PROPOSALS SHALL TAKE INTO CONSIDERATION ALL SUCH CONDITIONS AS MAY AFFECT THE WORK UNDER THIS CONTRACT. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES THAT THIS EXAMINATION OF SITE HAS BEEN DONE. N. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES AND NOTE CONDITIONS WHICH WOULD AFFECT THE WORK. ALL DISCREPANCIES SHALL THEN BE REPORTED PRIOR TO THE BID AWARD. 0. PROVIDE INSTRUCTION TO TENANT'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND RE TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS GUIDE. P. COi'PILE IERITTEN MANUAL OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP DRAWINGS AND A LISTING OF EQ iPPIENI" SUPPLIERS. ASSEP'SLE IN 8 -I/2' X II' HARD BACKED INDEXED BINDER_ MATERIAL SHALL BE AS FOLLOWS: 1) TITLE PAGE: TITLE OF JOB, TENANT, ADDRESS, DATE OF SUBMSSSICN, CONTRACTOR AMID ENGINEER. 2) I%D-XC 3) LIST OF MAJOR EQU:PrIEIT USED IN PROJECT ACGOI1PANIED BY CONiTRACTCR PURCHASE ORDER NI.R23E - RS AND SUPPLIERS NAMES AND ADDRESSES. A) ONE COPY CF EACH SHOP DIRAWING GROUPED BY TYPES cc EQU:PMDNT, I.E., ROOFTOP LIMITS, FANS, ETC. 5) SECTION FOR EACI1 SYST , f INCLUDING: A) BR.EF L_SGR. ?TIE E OF SYSTEE7I OPE.RATiGN ia1T: LOCATION OF A,iGR CO EWES . a B) HVAC SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS AND SCHEMATICS. O. SUBMIT A COMPLETED COPY TITLED 'HVAC OPERATING INSTRUCTION MANUAL' ON THE BINDING EDGE OF BINDER TO ARCHITECT FOR APPROVAL. AFTER ARCHITECT'S REVIEW AND ANY CORRECTIONS REQUIRED ARE COMPLETED, SUBMIT A COPY OF THE MANUAL TO THE TENANT. R. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER AND TENANT. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LCCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT DISTRIBUTION SYSTEM INCLUDING SIZES, AND THE AIR DESIGN FLAW RATES. 15600 HVAC BASIC MATERIALS AND METHODS A. THIS CONTRACTOR 15 TO BECOME INFORMED OF THE EXACT DIMENSIONS OF FINISHED WORK WHERE PIPES, DUCTS AND EQUIPMENT ARE TO BE PLACED AND WILL ARRANGE THE WORK ACCORDINGLY, ASSUMING ALL RESPONSIBILITY FOR PROPER LOCATION AND COORDINATION OF THE WORK. B. IN THE ERECTION OF THE DUCTWORK, SPECIAL DARE SHALL BE USED PROVIDING SUPPORT. C. ALL DUCTWORK SHALL BE PLACED SO AS TO AVOID INTERFERENCES WITH PLUMBING PIPES, ELECTRIC CONDUITS OR PIPES OF OTHER CONTRACTORS. D. ALL DUCTWORK MUST BE PROVIDED WITH SUFFICIENT DISTANCE FROM WALLS, PIPES, AND OTHER OBSTACLES TO PERMIT THE APPLICATION OF FULL THICKNESS OF INSULATION SPECIFIED. E. THIS CONTRACTOR SHALL PERFORM AN ACCURATE AND COMPLETE BALANCE OF AIR SYSTEMS AS A PART OF TINTS CONTRACT, WHICH SHALL BE COMPLETED BEFORE FINAL ACCEPTANCE OF THE WORK OF THIS CONTRACT. AIR BALANCING SHALL BE SUBCONTRACTED TO A CERTIFIED MEMBER OF ASSOCIATED AIR BALANCE COUNCIL 15660 DRAIN AND CONDENSATION DRAIN PIPING A. FURNISH AND INSTALL A GRAVITY CONDENSATION DRAIN PIPING SYSTEM UNDER THE ROOF, TERMINATING AT THE NEAREST JANITOR'S RECEPTOR. B. PIPING I5 TO BE SCHEDULE 40 PVC WITH DRAINAGE PATTERN FITTINGS, BONDED ACCORDING TO THE MANUFACTURERS RECOMMENDATIONS. 15700 HVAC AIR DISTRIBUTION AND RETURN SYSTEMS A. PROVIDE AND INSTALL DUCTWORK AND PLENUMS OF SIZE AND LOCATION AS SHOWN ON DRAWINGS. ALL DUCTS FOR AIR VELOCITIES LESS THAN 2000 FPM AND STATIC PRESSURE IN DUCT 2' OR LESS SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL_ THE GAUGE OF STEEL USED IN ALL DUCTS 5IALL BE AS FOLLOWS: I) WHERE GREATER RECTANGULAR DIMENSION 15 12' OR LESS USE 26 GAUGE. 2) WHERE GREATER RECTANGULAR DIMENSION 15 FROM 12' THROUGH 30' USE 24 GAUGE. 3) WHERE GREATER RECTANGULAR DIMENSION IS FROM 31 THROUGH 54' USE 22 GAUGE. 4) WHERE GREATER RECTANGULAR DIMENSION I5 FROM 55' THROUGH 84' USE 20 GAUGE_ B. TRANSVERSE JOINTS AND BRACING TO CONFORII TO 'HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" (SMACNA 1%95). C. ALL DUCTS SHALL BE RIGID AND SHALL BE CROSS- BROKEN, PROPERLY STIFFENED WITH SUITABLE BRACES, TOES, OR ANGLES TO KEEP THEM TRUE TO SHAPE AND PREVENT BUCKLING. ALL VERTICAL DUCTS SHALL BE OF STRONG ENOUGH CONSTRUCTION TO CARRY 100 LBS. SUSPENDED LOAD FROM HANGERS WITHOUT BUCKLING. SOLDER ALL JOINTS MERE NECESSARY TO INSURE TIGHT WORK. SEAMS OF ALL DUCTS AND JOINTS SHALL BE HAMMERED TO A SMOOTH SURFACE ON THE INSIDE. SEAMS ON OUTDOOR DUCTS SHALL BE MADE WATERTIGHT. LINE ALL SUPPLY AND RETURN RECTANGULAR AIR DUCTS WITH I' RIGID DUCT LINER. D. CONSTRUCTION INCLUDING HANGERS AND SUPPORTING SYSTEMS OF ALL DUCTWORK SHALL ALSO BE IN ACCORDANCE WITH 'HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE' (SMACNA 1995). E. FLEXIBLE CONNECTIONS SHALL BE INSTALLED ON THE OUTLET AND INTAKE OF AIR HANDLING UNITS AND FANS. THESE CONNECTIONS SHALL BE AT LEAST 6' LONG, MADE OF NFPA DOA APPROVED FLAMEPROOF FABRIC. F. FURNISH AND INSTALL VOLUME CONTROLLER AND EXTRACTOR AT ALL BRANCH TAKEOFFS IN SUPPLY AND RETURN FROM MAIN DUCTS TO ALL BRANCH DUCTS WHERE SHOWN. I,R4IT SHALL BE OF TWO GAUGES HEAVIER THAN THE DUCT. G. PROVIDE MANUAL ADJUSTING LEVER FOR EACH UNIT_ UNITS SHALL MOVE FROM FULL OPEN TO FULLY CLOSED POSITION TO CONTROL AIR DIRECTION AND VOLUME. H. FURNISH AND INSTALL TURNING VANES IN ALL ELBOWS OF RECTANGULAR DUCTS. THE BLADES TO BE HOLLOW - FORMED DOUBLE THICKNESS VANES. 1. FURNISH AND INSTALL SUPPLY, RETURN, AND EXHAUST REGISTERS, GRILLES AND DIFFUSERS AS SHOWN ON THE DRAWINGS AND SCHEDULE_ J. FLEXIBLE SUPPLY AIR DUCTWORK WITH I' THICK FIBERGLASS BLANKET 1NSULAT$Ca 4 WITH METALIZED FUJI VAPOR BARRIER OUTER JACKET. FLEXIBLE DUCT IN RETURN AIR PLENUM TO BE CLEARLY LABELED 'CLASS I' EVERY FOUR FEET. FLEXIBLE DUCT LENGTH MAY NOT EXCEED FIVE FEET. 15792 ROOFTOP PACKAGED HVAC UNITS A. UNIT SHALL BE FACTORY A58Et LED AIR TO AIR ELECTRIC COCL_JP G, GAS HEAT, UNIT WITH REFRIGERATION SYSTEM, AIR HANDLING SYSTEM CASING FULL CURB AND CONTRAS. B. CABINET SHALL BE GALVANIZED STEEL, BONDERIZED AND COATED MTH BAKED ENAMEL_ UNIT STALL BE ARRANGED FOR ALL EXTERIOR CGI 4ECT1ONS TO BE HiT14144 ROOF CURB. CABINET SHALL BE LINED WITH L' THICK NEOPRENE- COATED FIBERGLASS WITH EASILY REMOVABLE SERVICE PANELS TO ALL OPERATING CONPONEI4 S. HVAC SPECIFICATIONS • C. REFRIGERATION SYSTEM SHALL INCLUDE TWO RECIPROCATING SERVICEABLE HERMETIC COMPRESSORS, CONDENSERS, INTERWINDED CIRCUIT EVAPORATOR COIL, EXPANSION VALVES, SERVICE VALVES, VIBRATION ISOLATORS, CRANKCASE HEATERS, SIGHT GLASSES, FILTER DRIERS, HOT GAS MUFFLERS, AND REFRIGERANT PIPING. SAFETY CONTROLS SHALL INCLUDE FUSIBLE PLUG, LOW AND HIGH PRESSURE THERMOSTATS, COMPRESSOR MOTOR OVERLOADS, TIMER TO PREVENT SHORT CYCLING COMPRESSORS, AND LEAD -LAG SEQUENCING SWITCH TO CHANGE LEAD COMPRESSOR. D. UNITS SPECIFIED SHALL NAVE FULL ECONOMIZER PACKAGE INCLUDING ENTHALPY CONTROL, 1002 OUTSIDE AIR HOOD AND POWER EXHAUST. E. CONDENSER FANS SHALL BE VERTICAL DISCHARGE PROPELLER TYPE DIRECT DRIVEN BY INHERENTLY PROTECTED, PERMANENTLY LUBRICATED MOTORS. F. COILS SHALL BE ALUMINUM PLATE FINS MECHANICALLY BONDED TO SEAMLESS COPPER TUBES WITH ALL JOINTS BRAZED. G. INDOOR BLOWER SHALL BE FORWARD - CURVED, CENTRIFUGAL, BELT - DRIVEN TYPE, EQUIPPED WITH PERMANENTLY LUBRICATED BEARINGS. N. CONTROLS 1) THE COOLING SYSTEM SHALL BE PROTECTED WITH HIGH PRESSURE THERMOSTATS, LOW PRESSURE THERMOSTATS, LOSS -OF- CHARGE PROTECTION, INDOOR COIL FREEZE THERMOSTATS, AND CURRENT AND TEMPERATURE SENSITIVE OVERLOAD DEVICES. 2) ALL DEVICES SHALL BE WIRED THROUGH THE CYCLE LOC -TM CIRCUIT TO PREVENT COMPRESSOR RESTART UNTIL RESET OF CIRCUIT BREAKER. 3) FURNISH HEATING /COOLING 'T' THERMOSTATS TO PROVIDE STAGED HEATING AND COOLING WITH AUTOMATIC CHANGEOVER, LACKING OPAQUE PLASTIC COVER 'FAN ON' SWITCH POSITION. MOUNT THE BOTTOM OF THE THERMOSTAT 60' ABOVE THE FLOOR ON COLUMN AND 48" ABOVE TIE FLOOR ELSEWHERE. 3) HVAC CONTROL. SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL ELEMENTS ARE CALIBRATED, ADJUSTED, AND IN PROPER WORKING CONDITION. I. TIME GUARD CIRCUIT TO PREVENT COMPRESSOR SNORT CYCLING AS A RESULT OF A RAPID CHANGE IN THERMOSTAT SETTING AND AUTOMATICALLY PREVENT COMPRESSOR RESTART FOR AT LEAST FIVE MINUTES AFTER SHUTDOWN. J. FULL 14' ROOF CURB SHALL SUPPORT UNIT AND PROVIDE WATERTIGHT ENCLOSURE. CURB TO MEET NATIONAL ROOFING CONTRACTORS ASSOCIATION REQUIREMENTS. K. CURBS TO BE SUPPLIED BY THIS CONTRACTOR AND INSTALLED BY THE LANDLORD. COORDINATE PENETRATIONS OF THE ROOF WITH THE LANDLORD'S ROOFING CONTRACTOR. L. HVAC CONTRACTOR TO SET UNIT ON CURB AND MAKE CONTROL CONNECTIONS. M. ELECTRICAL CONTRACTOR TO MAKE POWER CONNECTIONS TO UNITS. N. HVAC CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL CONTROLS, CONTROL WIRING AND TO MAKE OPERATIONAL. O. ROOFTOP UNITS SHALL BE LENNOX. 15816 GAS FIRED UNIT HEATER A_ GAS -FIRED HORIZONTAL PROJECTION UNIT HEATER WITH DOUBLE DEFLECTION LOWERS, GAS SHUTOFF VALVE, GAS PRESSURE REGULATOR, 24 VOLT CONTROL TRANSFORMER AND THERMOSTAT, SOLENOID GAS VALVE WITH BUILT -IN RELAY, PILOT FLAME ADJUSTMENT AND PILOT FLAME SHUTOFF DEVICE. 13. SUPPORT UNIT WITH 3/8' ROUND HANGER RODS SUSPENDED FROM STRUCTURE. FURNISH AUXILIARY STEEL WHERE REQUIRED_ G. POWER WIRING BY ELECTRICAL CONTRACTOR. D. LENNOX LF24 -1OOS GAS FIRED UNITS WITH INDUCED DRAFT BLOWER. 15880 FLUES A. FLUE SHALL BE DOUBLE WALL TYPE WITH ALUMINUM INNER WALL, INSULATING AIR SPACE, AND GALVANIZED STEEL OUTER WALL. FLUES SMALL BE SELKIRK METALBE5TO5 TYPE PS. 8. SUPPORT FLUE FROM STRUCTURE MAINTAINING REQUIRED CLEARANCE TO COMBUSTIBLE MATERIALS. C. RUN FLUE THROUGH OPENING IN ROOF PROVIDED BY GENERAL CONTRACTOR. INSTALL ALL WEATHER VENT CAP WITH BIRD SCREEN AT END OF FLUE. INSTALL. FLASHING AND STORM COLLAR FOR FLUE. 15905 AIR DISTRIBUTION DEVICES A. STEEL RETURN AIR OR EXHAUST REGISTER - STEEL GRILLE WITH 36 DEGREE LOUVERS PARALLEL TO LONG DIMENSION, GASKET, FLANGE, 3/4' LOUVER SPACING AND VOLUME CONTROL DAMPER. TITUS 35ORL. B. SQUARE CEILING SUPPLY AIR DIFFUSER - STEEL SQUARE CEILING DIFFUSER, CONCENTRIC CONES, ADJUSTABLE PATTERN CONTROL TABS, REMOVABLE ELVER CONE ASSEMBLY, ROUND NECK, VOLUME CONTROL DAMPER, EQUALIZING GRID.. TITUS TIIS. C. FINISHES - FURNISH ALL AIR DISTRIBUTION DEVICES L-UTN PRIME COATED AND WHITE BAKED ENAMEL FINiSN COAT UNLESS SPECIFIED OTHERWISE_ D. COORDINATE AIR DISTRIBUTION DEVICE LOCATIONS WITH-! ALL AFFECTED CONTRACTORS BEFORE INSTALLING DUCTWORK. SIGNIFICANT DEVIATIONS IN LOCATIONS FROM TI405E SHOWN ON THE DRAWINGS MUST BE APPROVED BY ARCHITECT BEFORE INSTALLATION. E. SUSPEND CEILING AIR DEVICES FROM STRUCTURE CN HIRE HANGERS OR FROM RIGID DUCTWORK. CEILING MUST NOT BE USED TO SUPPORT AIR DISTRIBUTION DEVICES. F. SECURELY FASTEN SIDE WALL AIR D_ViCES TO RIGID DUCT'rNORK OR STRUCTURE. G. AIR DISTRIUTION DEVICES SHALL BE TITUS_ EQUAL PRODUCT BY re'TAL - ACRE, A.MEEr..OSTAT, NAILER, OR BARBER - COLEMAN NAT BE FGRNi5 ED AT THE ccer RACTOR'S OPTION. 15915 DAMPERS A. RECT`NGU'LAR OLICT GALVANIZED STEEL r:A.Nr3A . BALANCE AVD rOTORIZED DArVER E HIDE 16 GAUGE OPPOSED BLADES, CHANNEL FRAME WITH BRACED COPPERS, CONCEALED LINEAGE, TEFLON FILLED BEARINGS, 32' DIAMETER AXLE, 6' LONG CONTROL SHAFT. MOTGRIZED DA.` PER TO HAVE REPLACEABLE BUTYL RE MO? SEALS INSTALLED ALONG THE TOP, BOTTOM AND SIDES CP THE FRIJIE, AS TELL AS, ALONG ALL SIDES OF EACH I3JADE. • B. ROUND GALVANIZED STEEL MANUAL BALANCE DAMPER 141114 SINGLE 16 GAUGE BLADE, CHANNEL FRAME, STAINLESS STEEL SLEEVE BEARINGS PRESSED INTO FRAME, 3/8' DIAMETER AXLE EXTENDED 6' FOR CONTROL SHAFT, BLADE STOP. C. EQUIP DAMPERS WITH LOCKING QUADRANTS. D. CHECK DAMPERS FOR PROPER OPERATION BEFORE MD AFTER INSTALLATION. E. INSTALL BALANCE DAMPERS WHERE SHOWN ON THE DRAWINGS AND ELSEWHERE AS NECESSARY TO OBTAIN PROPER SYSTEM BALANCE. F. DAMPERS SHALL BE RUSKIN. EQUAL PRODUCT BY AMERICAN WARMING AND VENTILATING, LOUVERS AND DAMPERS, OR PREFCO MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 15939 INLINE FANS A. CENTRIFUGAL INLINE EXHAUST FAN WITH SHROUD, REMOVABLE MOTOR COVER, HINGED ACCESS DOOR, VENTURI INLET CONE, STATICALLY AND DYNAMICALLY BALANCED BACKWARD INCLINED NON- OVERLOADING FAN WHEEL, STEEL DRIVE SHAFT ON BALL BEARINGS, ADJUSTABLE BELT DRIVE, PULLEYS PERMANENTLY LUBRICATED BALL BEARING MOTOR WITH THERMAL OVERLOAD PROTECTION, SUSPEND WITH MANUFACTURED HANGERS AND VIBRATION ISOLATORS, MOTOR COMPARTMENT VENTILATED FROM OUTSIDE EXHAUST AIR STREAM, CONDUIT CHASE FOR WIRING AND GRAVITY BACKDRAFT DAMPER WITH EDGE SEALS. PROVIDE DISCONNECT AND ROOF CAP. LOREN COOK SQN -B. B. RELIEF CURB TO BE ALUMINUM 14' NIGH WITH RIGID FIBERGLASS INSULATION CANT STRIP FORMED INTO CURB BODY, DAMPER TRAY, AND WOODEN NAILING STRIP. C. ROOF OPENING TO BE FRAMED BY GENERAL CONTRACTOR. HVAC CONTRACTOR TO SET CURB 114 PLACE AND SECURE TO ROOF DECK. GENERAL CONTRACTOR TO FURNISH AND INSTALL FLASHING. D. HVAC CONTRACTOR TO HANG FAN, SET CURB AND SECURE, INSTALL RELIEF HOOD, BACKDRAFT DAMPER AND CONNECT DUCTWORK. E. ELECTRICAL CONTRACTOR TO PROVIDE ALL- WIRING. F. FANS SHALL BE LOREN COOK. EQUAL PRODUCT BY ACME, GREENHECK, PENN, OR JENN -AIR MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 15950 AIR CURTAIN A. AIR CURTAINS WITH ELECTRIC HEAT. AIR CURTAIN TO BE CERTIFIED IN THE FOLLOWING: MCA 220, ARI 410, B. HOUSING MATERIALS: GALVANIZED STEEL WITH INTAKE LOUVERS AND DISCHARGE NOZZLE. C. FANS: DIRECT DRIVE, GALVANIZED STEEL, CENTRIFUGAL. D. MOTORS: TOTALLY ENCLOSED OPEN, DRIPPROOF. E. ELECTRIC HEATING COILS: COILED RESISTANCE WIRE; WITH OVERTEMPERATURE PROTECTION AND CONTROL PANEL. F. PROVIDE WITHTIIE FOLLOWING ACCESSORIES: I. THERMOSTAT. 2. AUTOMATIC DOOR SWITCH. 3_ START -STOP, PUSH - BUTTON SWITCH. 4. TIME -DELAY RELAY. 5. MOTOR- CONTROL PANEL 6. MOUNTING BRACKETS. G. AIR CURTAIN SHALL BE MARS. EQUAL PRODUCT BY OMARK OR MARKEL MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 15975 INSULATION A_ DUCT INSULATION AND APPURTENANCES SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING TWENTY -FIVE (25) AND A SMOKE DEVELOPED RATING NOT EXCEEDING FIFTY (50). 8. CONCEALED ROUND DUCTWORK - FLEXIBLE FIBERGLASS DUCT WRAP LAMINATED TO FOIL REINFORCED KRAFT VAPOR BARRIER FACING WITH 2' STAPLING FLANGE, I.0 PCF DENSITY, K -0.27. OWENS- CORNING COMMERCIAL GRADE FIBERGLASS DUCT WRAP TYPE 100. C. INSULATION THICKNESS DUCT TYPE THICKNESS IN UNCONDITIONED AREA 2' IN CONDITIONED AREA 1' PIPE TYPE CONDENSATION THICKNESS 1' VALUE 7.0 3.3 VALUE 6.5 D. INSULATION SHALL NOT BE APPLIED UNTIL THE GENERAL CONSTRUCTION HAS PROGRESSED SUFFICIENTLY TO INSURE AGAINST PHYSICAL OR MOISTURE DAMAGE TO THE INSULATION. ALL INSULATION DAMAGED THROUGH FAILURE TO OBSERVE 1I15 DIRECTIVE SHALL BE REPLACED AT HVAC CONTRACTOR'S EXPENSE. E. HANGER RODS LUST BE PERPENDICULAR TO DUCTWORK BEFORE INSULATION I5 INSTALLED. F. INSTALL ALL INSULATION ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. G. INSULATION SHALL BE APPLIED OVER FLANGES, JOINTS AND SEAMS IN PIPING AND DUCTWORK_ H. ALL JOINTS AND SEAMS IN INSULATION SHALL BE PRGPE - PLY SEALED TO MAINTAIN VAPOR BARRIER INTEGRITY_ 1. INSULATION SHALL BE OWENS- CORNING. EOJAL PRODUCT BY ARMSTRONG, RONG, CERTAINTEED, SCHRULLER OR KNAUF MAY BE FURNISHED AT THE CONTRACTOR'S OPTION_ 15980 BALANCING AND COMMISSIONV1G A. AIL AIR DISTRIBUTION SYSTEMS ARE TO BE BALANCED IN ACCORDANCE KITH-GENERALLY ACCEPTED ENGINEERING STANDARDS, SUCH AS THE ASSOCIATED AIR BALANCE COUNCIL (AABC). DUCTED AIR RATES ARE TO BE rEASURED AND ADJUSTED TO DELIVER FINAL FLOW RATES wrruln :OZ A= DESIGN RATES. B. TI4E EECELENECAL SYSTEMS SHALL BE TESTED TO VERIFY THAT THEY ARE ALL WORKING PROPERLY TO reel' THE STATE ENERGY CODE REQUIREE 5_ PROVIDE A REPORT SHOWING THAT EACH PIECE CF EOUIPf1ENT WAS BEEN TESTED IN MS 5 VARIOUS FUNCTIONS AND IT PERFORMANCE FOR EACH OF T*4ESE FUNCTIONS. VERirr THAT TICE PROPERLY SIZED EQUIPMENT HAS BEEN INSTALLED AND RECORD ALL OF THE PERFORMANCE AND GENE PHYSICAL DATA FRCEI THE EQUIPMENT f ( • sd!tr c-* 1 1nr•r•r, �� 'r1 A PR _ 4 " Mop -o4 0 — bt REC.IF)E© CilY0FTLLK4' : A . V J 4 Jr: PERMITCH`Ef1 i 0 OC H6.1 DE 0100TaaasiiESs0 srl sr0t sours /0%14 661.00IMSE Me ma �Ir _AOrwo :.000 Ora _wB!oI SUM sPacsrceacoro.IatlE IrklE ras0. srs MIL 00SAMSAM WILT IMMIX sI ,Use: acatsINHOao<asaclerw SM # 0 DRAWING NUMBER: 1