Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-054 - PETCO
PETCO 17200 SOUTHCENTER PY M07 -054 Parcel No.: Address: Suite No: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17200 SOUTHCENTER PY TUKW Tenant: Name: PETCO Address: 17200 SOUTHCENTER PY , TUKVVILA WA Owner: Name: Address: Contact Person: Name: PAUL JOSEPH Address: 4426 221 PL NE , REDMOND WA Contractor: Name: PERFECT CLIMATE INC Address: 4426 221 PL NE , REDMOND WA Contractor License No: PERFECIO22D5 Value of Mechanical: $72,000.00 Type of Fire Protection: Furnace: <100K BTU > 100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 5 0 0 0 6 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: INSTALL ROOFTOP PACKAGED UNITS RTU 1 -5, INSTALL EXHAUST FANS 1 -6, AND INSTALL UNIT HEATERS CUH 1, 2, GUH1. Phone: Phone: 425 260 -6955 Phone: 206 - 977 -7353 Expiration Date: 03/11/2008 M07 -054 05/25/2007 11/21/2007 Fees Collected: $746.35 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 20 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 doc: IMC -10/06 M07 -054 Printed: 05-25 -2007 Permit Center Authorized Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us talt- Permit Number: MOT -054 Issue Date: 05/25/2007 Permit Expires On: 11/21/2007 Date: s- c -0 7 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of thi ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or e p rforman work. I am authorized to sign and obtain this mechanical permit. Signature: / (1 P Print Name: /�` Date: S 2 S — C)2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspendec or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M07 -054 Printed: 05-25 -2007 Parcel No.: Address: Suite No: Tenant: 17200 SOUTHCENTER PT TUKW PETCO 1: ** *FIRE DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -054 Status: ISSUED Applied Date: 03/21/2007 Issue Date: 05/25/2007 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: H.V.A.C. units rated at greater than 2,000 cfm require auto-shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 4: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 5: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 6: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 7: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 8: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 9: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 12: ** *BUILDING DEPARTMENT CONDITIONS * ** 13: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 14: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 15: Readily accessible access to roof mounted equipment is required. 16: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed doc: Cond -10/06 M07 -054 Printed: 05-25 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 17: Manufacturers installation instructions shall be available on the job site at the time of inspection. 18: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 19: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 20: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M07 -054 Printed: 05-25 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the p °nuance of work. Signature: Print Name: 1 K / Jd SG� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: Z S doc: Cond -10/06 M07 -054 Printed: 05-25 -2007 Community Developmen.jpartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://www. ci. tukwila. wa. us MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: l7aoo Sou'11 -N Ct=")t rce.. ' \Lwy Suite Number: — 2 Floor: Tenant Name: ?E'S — C_P Property Owners Name: t , ?\ QroC�L5LTI LLC- Mailing Address: i43\\ 1 "� N (> �_ Vl. ELL. City CONTACT PERSO - who;do' a contact when your.permit is ready�to be issued Name: 9144......\ — 705e >� Mailing Address: LILA a G e C. i1JE E -Mail Address: ?CI—) WI vi . 1'1)- t,CCDr - \ Company Name: Mailing Address: q 40..0 aa.1 A L l `7C LA A-� F7) ►9th C_ e n n - , Contractor Registration Number: PE.rZ..c-- - (r 22_,T, S Contact Person: E -Mail Address: Contact Person: W1 1 \ \ \ AN• ���A - f 7) (%) E -Mail Address: E -Mail Address: Q: Applications\Porms- Applications On Lined -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh King Co Assessor's Tax No.: Day Telephone: S 64) - 6e SS City Fax Number: u12S = �', �s 6-3 °l U City Telephone: Fax Number: New Tenant: ❑ .... Yes ..No w�- 9cs00c State Zip State Zip Ljr - 9150 State Zip CP 2A tt - 69'5 97-S^ 3186 Expiration Date: S-1 \ — o b ARCHITECT RECORD ;Alt plans must; be wet ,atamped by Architect ofl , Company Name: tip-. UU? � {' .,nS A 1— ?Adv S �S't✓ Mailing Address: G D Chi C? (�t'C -- � PlsT d / ( - € - J - i L c,)03 ity State Zip Day Telephone: E3 S�J" Fax Number: 7 All plans must be wet stamped by Engineer of Recor Company Name: 'PCB L`A -1^1_ S CO.Just,i . n A-4 Ell) 67 7, C. Mailing Address: 2] t-\ TY\AA. ry s r St., k, fE 243 nnoc, reSTMw iv i S Oq) OS 7 City State Zip Contact Person: J e.-5 L4)1 1' T Day Telephone: 3S Z — C S Ov Fax Number: Page 1 of 2 Unit Type: Qty Unit Type: Qty ; Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser a 0 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 0 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ 7 Ovo. Scope of Work (please provide detailed information): Z4v5rFAN Czo f ' )' Wfit =tr> t a ns cvs "R a-- S 1 N sr-' ■ Ffwo 5 1-6 1 N 51 f t 4) no LT 67 LA 1 N- 1 Use: Residential: Commercial: New .... ❑ Replacement .... ❑ New ....X Replacement .... Fuel Type: Electric ... Gas .. Other: Indicate type of mechanical work being installed and the quantity below: Srnt! Value of Construction — In all cases, a value of construction amount should be entered by the applicant.. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ()NWT OR AU RIZE D AGENT: Signature: Print Name: P�� r - 3 - 0Sisq � Mailing Address: ( -I Ll 2l-, a- ∎ S' pc_ VL Date: S 2. 1 — U Day Telephone: - G °j CS' RED City b4C3 - S_ State Zip Date Application Expires: Date Application Accepted: r i 21 1 0 ,.. 4 __ Q:\Applications\Forms- Applications On Line\3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Page 2 of 2 Parcel No.: Permit Number: M07 -054 Address: 17200 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 03/21/2007 Applicant: PETCO Issue Date: Receipt No.: R07 -00950 Initials: WER Payment Date: OS/25/2007 01:14 PM User ID: 1655 Balance: 60.00 Payee: PERFECT CLIMATE INC TRANSACTION LIST: Type Method Description Amount Payment Check 7473 603.08 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 603.08 Total: $603.08 Payment Amount: $603.08 8641 05/25 9716 TOTAL 603.08 doc: Receipt -06 Printed: 05 -25 -2007 Receipt No.: R07 -00402 Initials: JEM User ID: 1165 Payee: PERFECT CLIMATE INC. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: M07 -054 Address: 17200 SOUTHCENTER PY TUIKW Status: PENDING Suite No: Applied Date: 03/21/2007 Applicant: PETCO Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 7378 143.27 Account Code Current Pmts 000/345.830 143.27 Total: $ 143.27 Payment Amount: $143.27 Payment Date: 03/21/2007 11:23 AM Balance: $603.08 7/21 -7 7L doc: Receiot -06 Printed: 03 -21 -2007 Pr 6 [0 0 Type of I1.J L Address: 1-7 2.00 S(S\ i L40 C- 0 TE Date Called: 2 k Special Instructions: Date Wanted- y 1 � � fa.m' 'pm" Requester: Phone No: 5 0q - L-1 75 - z.00 5 INSPECTION RECORD Retain a copy with permit 05C INSPEtrION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OM MENTS: /7/ t Approved per applicable codes. Corrections required prior to approval. 0 $58.0 INSPECTION , REQUIRED. Prior to inspection, fee must be paid 6300 Southcente Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: Type of Inspection: Address: 72 — r// tier A / Date Called: Special Instructions: Date Wanted: l,r �7_� ��--��... CP f • Requester: Phone No: �� - / - 2 )c El Approved per applicable codes. /7 )C)7 ) C / INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 gi Corrections required prior to approval. COMMENTS: /EE 1 Inspecto ,, / 1Date: 9 7_12 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: !Date: V�- Project ) / ? Type of Inspection' ,Si'!i4'Lv %-'/ ; �.6;)r Address: /720c:, S»,4 P Date Called: Special Instructions: Date Waited: 7 Z 7 r� Requester: Phone No: -7 5-US -- q / 5 - z �'j INSPECTION RECORD Retain a copy with permit INSPE N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: /4 l e‘e-t4e It Date: \ L /767 - $58.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: (Date: Project: //:-0 Type of Inspection: 7e Called: �s�. Address: /? 2- 0 S 7 Special Instructions: Date Wante a�.m - � �� C ry Requester: Phone No: , 7 7 , 7/ ^� S `/4 INSPECTION RECORD Retain a copy with permit °s INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -36170 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7 —_3 4 a /<,- 1 c2J, Grp S $58.00 R NSPECTION FEE2EQUIRED. Prior to inspection. fee m st be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: I Date: Project:/) / Type of Inspection: ?7 -,..d Z2/ 7 54(1 Address: -Gr, te (72 4f Date Called: . Special Instructions: _ ? 4_,/1 , ' O ate Wanted: ac. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /3 7, 4,4 ,/ 4 1-eic 1 //7 0 7i'M i i 7 /E°.e 0 / El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: Date: Projt: Type of Inspection: Address: 1 7 Zoo Semthee,14( r Put Date Called: Special Instructions: _ Date Wanted: (� - 13- 6 - 7 a.rr► , T Requester: Phone No: 3oc- y - 70 i c INSPECTION NO. NSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 O (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: .00 REINSPECTION REQUIRED. Prtfor to inspection, fee must be d at 6300 Southcenter lvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: Type of Inspection: Address: 2.E 1 7 6 r i� ,4-, Date Ca : Sp cial Instructions: D Wanted: 4m. Requester: Phone N° • p — ` ,75 -21v/ 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3b7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6 , e r ' J - z / 7 • / ) . - 7 ❑ $58. &(REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Sprinklers: Fire Alarm: Type of Inspection: Hy/4c j f -t Iicd.-t< ie# c l) 2e - „..0„,s, -c / -10 Sic) : Rro—r ) )044-7 /27v —1 e2'Tu - 3 i TCU -1 / . i27L - 5 ,-t- -4- / 1-11/4C - 5 " . ; - : - / i G c -5 h, 2 4 r �uLe..„, , Phone No.: e25” .. - si- 3/ 3? Project: p , Sprinklers: Fire Alarm: Type of Inspection: Hy/4c j f -t Iicd.-t< ie# Address: / 7 2vo Suite #: 5G,4.4 - he ee,b . r lu. Contact Person: /di-c Special Instructions: Phone No.: e25” .. - si- 3/ 3? Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 ri Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT ,oG - yG S' /110 059 PERMIT NUMBERS I - I Wrrections required prior to approval. Inspector: .5 Date: 7/at /c, 7 Hrs.: / _ $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. 1 1/13/06 f Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 CT E N G I N E E R I N G Structural Engineers PLLC (EXPIRES: 7/27 FILE COPY Permit No. Pim r_ STRUCTORAL CALCULATIONS For HVAC Roof Top Units PETCO Building E @ Southcenter Square Tukwila, WA REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 4 2001 Of Tukwila BUILDING DM ION RECSVED CITY 07 TUKWILA APR 2 0 NOV PERMIT CENTER CORRE TION LTR # � 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285- 4512(V) (206) 285- 0618(F) Mot -O5µ C T E N G I N E E R I N G Project: Ol� i4 C1 Structural Engineers P L L C Date: e: - o1 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: Client: Page Number: (206) 285 -0618 F - Y"`\/ I '\ '{ ,\AL Gi. l [ 1 C .�. Lc) �., i i r"� ,. 1�;+ 1 V `/ \,1\t S%...+ ft �� 1. Y T H'. - `-4.. , b.,,7 { C.)cSr f'' f: r f`1°' i t,_ (',,.,A`o T h"r.1",S,, L M€ i � + L . O C L ! W r 4 . - C Z ° i ' : ` : 1 `-R T F i= `1 , Nz '',d'a, h! . - E-- 2.1 Or Ttkt. :17t? C;. r2bWN)NIC,. I l)rs, -e -: , ,;fE+ '(‘1C >i 0 e rr.,r:,) 2 () c.N �► ;a,}?0v- a 60. - i`Ft - E SVO AT i._4C C«Ya. - O° S F . ( /g) 2. •S SL(Pt • • u5L 41 22 4h lr^I (Lt_ NcS( Faortit A E 7-02 - 7"P 1 (l P %_'� 11 � S 5 ( 2s-4 - 2 EC), SZS h = 1 8Gf,C54' J - . Cow L t:7 E. - .40 Cs % s - act <z, (A,aZc 'A a V 4 aarq 5 TEIM PER MEET Gil t'F"rrIl .d qo/t Pelt r. y M. I EE4RE s KAI e•wt Q Mm y wine w lr t Ian ..IM. not ma II/EO1. w q .ans w INO• MI I . ® I AIM w. YAM S.Tq • Eallaa• w yr < >I. w•�a MM asset WYKl • NMI RR OM ••.M II TIM MI. WY ROOM IMr. MOW. � �lWW�I .1 WM Ili MO WO OM O .IM • =SW f ., a.rl IIII O. q'M"°. =SW Mlle M .alt ... . sae O.I • To - 4 _a TIM! ala i re w 011111111001 01010111101 CONSTRUCTION DOCUMENT FOR SOUTHCENTEF SQUARE TUKWILA, WA NORTH ROOF FRAMING PLAN FOR' E BUILDING NORM MAW/PM WWII% .A.11 .1110111101•910 1.111.11N11.11. nai aEcISIatlol tnG I1911WMRRM - sN °Ib ES -2. 11 F ft 7 -4 17 z c • c51 c 6" 0 —{j - �j f 3 i t;' !�. fIttf I I 1 1 E tTT it l %'[I' it a 1: it 1 ` r lti lli L t > i tt a # t t r lt high! Art f 3r JE i ri 1 fitl illPith i tl Lil it 1fi ►i1i t l ilt l It ,tIl Li f ti i I in t � l itt f l t t p i iref Owl! It Ill 1 }t r t t ` i t 1 plop f # [ O i t R' t rig 1 1 lttt� G -. q} t.i ri�t ; irsA jji Ijj I } 1 f i t I , r t i E . t l r j i t[ tiI !' t , 1 t t 1 } t i v ` ft�¢i ' 1 1 ' { t+ a i , ti tlir , r =l In .ii t ohm PETCO PETCO ANIMAL. SUPPLIES, INC. EOUINCOAER (WA) MOO IIOIRIIG9R MRfWAY 1UPWAAWAiMN7 0RM1110 Polaris Cowin rww.w ran nom _ ter wyr� •r•00.09.1.• r••• Ybi L 1111m CT EPIGINEERING r' Project: CThLS -A. (206) 285-4512 FAX: lent: Page Number: (206) 285-0618 PLLC Date: 4-10-0'1 180 Nickerson St. Suite 302 Seattle, WA 98109 - FQ s orz - •1• April 6, 2007 Paul Joseph 4426 221 PINE Redmond WA 98053 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M07 -054 Petco —17200 Southcenter Py Dear Mr. Joseph: This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely encl nifer 44arshal it echnician xc: File No. M07 -054 P:VenniferCCorrection Letters \2007 M07 -054 Correction Ltr #1.DOC jem City of Tukwila Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: April 5, 2007 Project Name: PETCO Permit #: M07 -054 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Plans show installation of (4) 1,859 Ib. RTU's. Please provide engineer calculations with details that shows location and roof construction shall be sufficient to support the weight of the new RTU's. Details shall identify any additional supports required and how RTU's shall be secured to the roof. Should there be questions conoeming the above requirements, contact the Building Division at 206431- 3670. No further comments at this time. PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -054 DATE: 4 -20 -07 PROJECT NAME: PETCO SITE ADDRESS: 17200 SOUTHCENTER PY, SUITE 100 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # before Permit Issued DEPARTME�N�T�S� ""1 Buil i�lvislon Public Works ❑ APPROVALS OR CORRECTIONS: Ir 2-28-02 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 4 -24 -07 Complete rv Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROyTING: Please Route 11011 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Planning Division n Permit Coordinator ❑ DUE DATE: 5 -22 -07 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 -054 DATE: 03 -21 -07 PROJECT NAME: PETCO SITE ADDRESS: 17200 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: i t4,01 Bui • g Division tCf Public Works Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY �° PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete rril Incomplete TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ Permit Coordinator ❑ DUE DATE: 03-22-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DATE: Planning Division C Permit Center Use Only CORRECTION LETTER MAILED: ly Ins fl Departments issued corrections: Bldg .1 Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 04-19-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) t7 1 Notation: REVIEWER'S INITIALS: DATE: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431 -3670 Fax: 206- 431 -3665 Web site: http : //www.ci.tukwila.wa.us Steven M Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, eta M DI- i)g-1 Date: Plan Check/Permit Number: ❑ Response to Incomplete Letter # '7'a Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: SDI D4 - vc.. c4. Project Address: / ? aZo o P141(4-4i4 /� y Contact Person: 4/'7 ; �� t / - Phone Number: - 3-0 5 - 9S 3 - o ? 6 Summary of Revision: S7< R C / CAL c u /A ]. 0.1 s Lo t( / U H/ ; - )-- s - 0 12 t� e-rz C o — RECEIVED 2 P .Mi F VY`3'6 i i4 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on *Lid_ applications\fornu- applications on linekevision submittal Created: 8 -13 -2004 Revised: (7140A-- License Information License PERFECIO22D5 Licensee Name PERFECT CLIMATE INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601844179 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 4426 221ST PL NE Address 2 City REDMOND County KING State WA Zip 98053 Phone 2069777353 Status ACTIVE Specialty 1 AIR CONDITIONING Specialty 2 AIR HEAT,VENTILATION,EVAPORAT Effective Date 3/25/1998 Expiration Date 3/11/2008 Suspend Date Separation Date Parent Company Previous License PERFEC" 054DB Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 CBIC SB4087 03/01/2002 Until Cancelled $6,000.00 03/11/2002 #1 CBIC SB4087 03/01/1998 03/01/2002 $4,000.00 Business Owner Information Name Role Effective Date Expiration Date JOSEPH, PAUL G 01/01/1980 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= PERFECIO22D5 05/25/2007 r 1 • H LANDLORD: Wig Properties. LLC teshyo 4811 134th Place NE 8edlewe, WA 98009 (425) 957 -4774 Ignorri- Lummis Architects, L!P. 601 Chopd Avenue East Chary 1111. NJ 08034 (856) 428 -8877 Contact: WDAlom Fearon, Project Architect MECHANICAL /PLUMBING ELECTRICAL ENGINEER (TENANT IMPROVEMENT) Polaris Consulting Engineers, P.C. 214 Moin Street. Suite 208 Moorestown, NJ 08057 (856) 778 -5400 Contact: James Watts, P1IE Designer ARCH. DWG. ABBREVIATIONS AND SYMBOLS COMM POUND at NUMBER ACT: ACOUSWCAL CERRIG RE AD/ ADJUSTABLE AL ALUMNA ARMOR APPERCOIA1E AROL A10INECRNN. ASPHL ASPIUILT B.C. BACK OF OMB B0. BOARD BIlU1 EMUNRIOU S BLDG 81RM BR KOCK BR BEAM ILO. BOTTOM OF • CABINET all OMIT CER CfRAHC CL GIST RON CF. COLD FORM C.& CORNER GUARD C.1 CONTROL JOKY QC. CUM CUM. CWUCR1c UR CLEAR evLU MCKIE 11AOORY UM CO. CASIO OPENING OoL mum -- COMC: CONCRETE COIL CoNOECiION COWL OOIISDRICB111 CONE CONNpOUS Cowl CORRIDOR MR COIN11RSUK a CORNIER GL CERAUC TIE CIR CO ER D OEPDH BBL. DOUBLE DEPT. DEPARIWENT O F. ORIKNIG FORRTAM DEL DETAIL DIA. METER oDl 01019014 O SP. OISFE NSER DR DoIN OA ODOR WOOS DR DOOR OW CRAM DIM. DRAINS EA. EACH • EIFS Erma tam d FN I SYSIFR Q_ IT VA10N ELEC. REClRICAL OFR E EROENN. f ENCL ONCU)SURE BI EO.UY. OIL EaU4RA RENE ETC: EIEC6IC NLAER GOOIER DST. DMUS - DPO. EXPOSED DP. EIPAN9011 Eix>C EXMOOR EIRE CORKED FADE. FABRICATOR/ FABiICADD F.0 R MO owim. F.D. RDat OItAII FDN. fOU0A1011 FS AOOR SDK FE EW EKTNON4ER F.E.C. fRE Oxmausnot CAT fM. FORM EKE ROUE ft. ROCK RASH. RAMC RUDE RDeResanr Enc. FACE CF C NCREE FCOF FACE OF 6191 FOR. FACE OF IUSO eT FAS. FACE OF SIP" fRifC raTANG BP. FIBER CLASS D9LNILED PODIUM •/d RL 1R FRE fETNIMMIf WATER FL FOOT OR FEET Fit. . - R I K RAMC CA. CN.VRNGE Q_ CUSS MOE CO. WS BBc MUM 1111//10180 Ra 111E Iii RC. IMMO ODiC Rio WAVY DOLT ED4 IVADBOOP fDE DA RDIMRE• RR. RUM FEW ndIIZ 110111201121. iR HOUR IOW NSS 1101/011 SEEK S7B[110E 40-Or LNL MODE OMENS= fMf FL l4 EWIATB4 01ASS IISiE_ _A= RL MOOR �-- DUR alrloR MOO IEaL IEDi. . IEL IN. Y0. MR. *LC. NO: NOM. ICES ORS QC aft BC. OIL OPP_ PBCS . PI- P. LAM. PEAS PURE RIAD P.O.C: PR. P!L It PE: PIG. aT: R RNL RA Rif REFit SEINE FECO .tom NILE R!L R.4. R.UL RIIC SC SOPA sm SR SPEC. SPECK SST: s1a STL SKR. 9U6P. 1EL TDB U P. EC./SP. Ti6 lit LCL TP. 15 NEON DENSITY OWRIAY IECwICAL MEOW MEMBRANE METAL MANUFACIURER =MUM IBSCEUANECOS MOW OPENING 1101S1URETANT DOUNDD NOT 11 CONSULS MOM/ NOrRW. NOT 10 SCALE CREWEL OBSCUPE ON ONTER OUTSME IMEN9ON O AOdJE GUMS, OIDDIPAC OPEtI1P OPPOeSi1E FRE -CAST PLATE PEASDC LA WRIE PUDIC PLYWOOD PORT OF CO MECO N PAR PRESSOIE MEAiW PONE PANTED QUARRY DLf MEER RADIUS ROOF ORAN REFERENCE REiAATOR REINFORCED REBUKED S ESRENE RET -G ROa1 ROUGH DEEM NG MVO SIT RAMMER COfcucNOR SOLD ONE 9CIEDUED SHEET SAT O KW MOLAR SPSOFICADO N SPECIDD (SECROLQ swans STEEL STANDARD SIEEL =RACE STRlCRRtAL SUSPENDED EDP Cr CIAO ELEPIENE AVM AID CROKE MIMED cuss WOW .--- CY CUM MOOED SPANDREL CUSS TDODEo MUM CUSS TOP OF TOP OF PMEMMT MBE SKR • II Mercantile (Sean 309) • Baling Sind Tlpe of Consb action (Table 503) V-8 NINE • Aiocable areas (siih Fitly Spri ldered System) (Table 503) Tenant Spate kerc M 151204 •Ere Seperation Asserabtr Between Osep M Tens*, wa h e scup -on for ray ri ie ed Spt n Table 30232) none EEO. 1 PRODDED BY MEOW •Oecepant Local (Table lO01.1.2)[tiross) M Croomig) 14,417 S.F. : 30 SF./PP. = 481 PINK M (Stock) 787 SF: : 300 SE/P.P. = 3 PERSONS OLxapad Ind = 484 PERSONS • APPl1CA11.E CODES EURDING/S1ROCIURAI. CODE 2003 i1IE1WADONAL BIRONG COOE PLUMS COO-• 20031NFCillf PII LNG CODE MEC HiC & CoOE: 2003 Nf I RATIONAL IE0IANlCSL COOS 11/ ■IiSIPIGTON SIAIE AIDIDiENIS BEC1RIcM. CODE 2005 NATIONAL EIECHBCA. COOS AOCESSERl1Y COME: PRONSIONS TO AE 2003 BC CNAP1111 11 2003 NIS! 117.1 FIRE 000-• 2003 NIUDIAAONAI F11E COOS • Egress 11Wt h (Table 1005.1) Refired M (Reid &Grooming) 481X0.1511.= 7215is. M (Slodc) 3X01SiL= 0.45 7320 iL • MA%R CLOSETS 1 EA SEX PER 500 POEMS REWIRED PROMO • Larobories 1 Ell SIX PER 750 PERSONS REQUIRED PRONGED • I ii*ng Robin 1 PER WOOD PERSONS REWIND PRODDED • SERNCE S E REQUIRED PRONGED STORE FIXRIRE DMA REGARDING NHS PROJECT: 1. The highest store facture for merchandise (rocking) for this height to the top of store than 10 feet ore fixture. 2. The highest that merchandised be stared rh metal and reoelving /stock areas is less than 12 feet height to the tap of merchandese. 3 • • • • • TENANT IMPROVEMENT FOR A NEW PETCO STORE "SOUTHCENTER (WA) #237" 17200 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 Mol-054 CURRENT ISSUE DRAWINGS SHEET DRAWING T11LE A0.1 Code Dato, Project Data A0.2 PETCO Vendor / Contractor Furnished Items A1.2 Balding She Verification Plan A2.1 Floor Plan and Partition Notes A2.2 Floor Finish Layout Plan A2.3 Store Fixture Plan A2.4 Reflected Ceiling Plan A2.5 Roof Plan A3.1 Door & FNixstn Schedules, Door & Storefront Types A5.1 Front Elevation, Interior Wi a1 Sections A5.2 Exterior Wall Sections A6.1 Exterior Details A7.1 Large Scale Pions A&1 interior Details A&2 Interior Details A83 Interior Details A9.1 Interior Elevations A9.2 interior Elevations PIIE1.1 Plumbing / Mechanicd / Electrical General Information P1.1 Plumbing General information & Schedules P21 Plumbing Man P3.1 Sanitary Large Sccie Plans & Details P3.2 Water Large Scde Plans & Deus P4.1 Plumbing Ms' er Diagrams & Details M1_1 Mechanical Generd Information & Schedules M21 Mechanical Plan 113.1 Mechanical Large Scale Plans & Details M3.2 Mechanical Details F1.1 Fore Suppression General Information & Schedules E1.1 Electried Ge nerd information & Schedules E1.2 Pond Scheddes E1.3 Electrical Six* tine (flagrant and Detects E21 Efechicd lighting Plat 12.1A Electrical lighting Diinalsiond Plan E22 Electrical Power Plan E2.3 Sound and Ccr inismicotian System (2.4 Security System Plan E2.5 Energy Management System Plan E3.1 Electrical Large Scde Plans, Details E3.2 Electrical Large Scde Plans. Details EMS1.1 Energy Management System kifarmotion & Details Peimlt tim RBI Won /Wad Is *Med b ems ad wader& & void cf '~ .xROrl cbconeds does not artertm Coe 'tartars C. 9 _ " Q a Date S2 Ilo dance; shall be made to the FJC M t F t.` c1 Dirt prior f � T: z CURRENT ISSUE DATE ISSUED Addendum 11 12/14/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 Addendum 11 12/14/06 100% Completion 11/30/06 Addendum It 12/14/06 Addendum 11 12/14/06 Addendum 11 12/14/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100X Completion 11/30/06 100X Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100X Completion 11/30/06 100% Compeetc • '301.6 100X ..3.9os:. 100% 100% 100X - 100% : t; :4/06 100% Can- .on 11/30/06 100% Cony:atice 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100X Completion 11/30/06 100% Completion 11/30606 1002 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100% Completion 11/30/06 100X Completion 11/30/06 k-. .:IATEE PERMIT . ._ FRED : 1 cs : TLattldd DIVISION • MEWED cavocItastta X12 21 237 Mb� --owl 1007E Co pfelon Addee hdum D1 E E zti 3 in E e3 E EIS V t: • €g 11130106 12114106 •- Lad•t• •E1OO PIN 1Di 7424 06079 Damp OCOED POI Illtf aONhsRRaoResi sou voscv swim 00ROMONSAM) CORRELATE O E3 ►S Mon TOPROMPO TM wow OE:URED M 142M ORAMAGS AID 9W.L PROW LV nolinr TrF'Wawa=CFAAY CaSt2ES aoaraGFr; t ,AtARs 17C4 iEG3 THAN.. CRIzED REIVOILAGVIS ORO:N EFt OF 7 CODE MATA PROJECT DATA 4 ___LIC0.1 • 1 J 4 • 4 ea • a 1 0 4c7 1 O LYI a* 1 1 1 { • 0 PO N II 1 1 11 Will 1 PE" a 4 ; 9q ; :I ht A a 2; 0 g qr IOW gl; gg 194 go I le 1 0 • pcTcQ 9126 RIIHCO ROAD SAN DIEGO, CALIFORNIA 92121 PETCO ANIMAL SUPPLIES, INC. SOUTHCENTER (WA) #237 17200 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 1GNARRI-LUMMIS ARCHITECTS LLP 601 Chapel Avenue East David N. Lummta AIA Cherry HilL NJ 08034 -I492 WA 7504 Phone (856) 4284877 Fax (856) 4294379 www.ignarritummiicom • REFLECTED cEIUNG PLAN NOTES. GENERAL 1. VERIFY MEASUREMENTS NINTH CORRESPONDING CONSTRUCTED OR COSTING CONDITIONS PRIOR TO PROCEEDING SOH THE MIORIC, AND NOTIFY DE ARCHITECT IMMEDIATELY OF SIGMFICANT DISCREPANCIES USING TIE 'CONTRACTOR REQUEST FOR INFORMATION' FORM (01200) AND SUPPLEMENTARY CONTRACTOR DETAILS AS REQUIRED. 2. REFER TO SHEET A0.2 AND PROECT MANUAL SECTION 10300 FOR DESCRIPTION OF TIE DIVISION OF RESPONSIBILITIES BEITEE N PETCO VENOORS AND CONTRACTORS 3. S1f19301. KEY- 1=3 1 1 a s LIGHT FIXTURE IN SUSPENDID ACOUSTIC DE CEILING / REF ELEC. PENDANT MOUNTED UPLIG}IT MTH REFLECTOR / REF ELEC. NA NARROW STRIP NTH REFLECTOR / REF. C. SURFACE MOUNTED / UINSIRUT MOUNTED LT. FIXTURE / REF. ELEC. 0 LOW BAY LUMYARE DIFFUSER / REF. MECH. CONCENTRIC DIFFUSER / WE KM (ACT- ) CEILING TILE TYPE/ REF. All, 09510 11 B 1 • *SALES OPEN TO ROOF STRUCTURE NILNESS ROOM 116 EL 8 CEFNG (ACT-2) WORK ROOM 115 EL 8 -0' CEIUNG (ACT-2) 8'-Q 3 1/2' SOUND ATTENUATION BATT INSUL ABV_/ON SI!SP. ACT MMNTAN CLEARNE( FROM LT_ FIXTURES HENS EID CEILING (ACT - -2) a. 8' (ACT -2) CORRIDOR (ACT -1) aim ..14/1TORs CLST l ■ /111 BREAK ROOM ■ ET_ 8' -0' 11 11 11 11 1 1 D PROVIDE A.C.T. HOLD DONN (lCLPS i RESIROOMS EEO 0 i 0 1 1 l 4 WAY I 1 1 11' . SOFFIT 0 PROW ` ► RESTRAINTS AT ALL SUSPENDED CFRUNG . REFER TO DUAL 11/A83. 1 0 1 1 0 1 f l 1 1 1 1 1 RETAIL 102 r 1 1 1 1 1 1 1 1 1 1 • 1 1 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 • 1 1 1 1 J 1 I, 0 1 1 B.O. CONCENTRIC DIFFUSER 1.1. 15 ABOVE HNISH FLOOR (TUFF. AT 4) 0 0 1 1 1 1 J 1 1 3 1/2" SOUND ATTENUATION BATT ABY./011 SUSP. ACT MAINTAIN FROM LL FIXTURES 1 1 1 1 EL T -11' GYP- BD SOFFIT 1 GROOMING SALON ilffl :-0r COM 1 1 1\4p -05 ° PROVIDE A.C.T. HOLD -DOTN CUPS N VESTIBULE 1 I ADOPTION AREA ACT: -1 d1- uf-o. OFFICE CEIlTNG ® c%P. e . asUNG CONSTRUCTOR 5/8" M&CYP_BD.ON7/rx20CAF:G 12 QC., ON PERPENDICULAR 2 1/2 x 20 GA. NET: OWING JOISTS 24' OIG, SUSP- FROM BAR JOISTS MOE 1'. Fl Ns cmali -=frm IN 111111' :Au IrOirl I g g> I r!uI E� ►I 11111 1.11.1 ._ Il • 1/2' X 1/2' 1NF1U =CRATE DFFU`: iH LEU OF ACT. THIS IRE ONLY (09510) GROOMING RE ► • mp CT. SOFFIT REFLECTED CEILING PLAN REF_ A23 ,c01 E REVIEWED FOR CODE COMPLIANCE APPROVED MAY 24 2001 City Or Tukwila IRD ION RRODIFED aw MIR 21 4$I 01 1r =ra OWE 100%ComproSon 11/31106 &Addendum 11 1214X6 7424 I 06079 ioecsas vlFS 0 0 1 1TRAC1011•49•LL user ouslim capon mu CORRELATE O11 o11s MCA TOPR NONGr. 110FeC OETAI ED THESE MOMS. A1O SHALL PROi1FZrzG:FY THE i ; OF MY 0 COPIPIT704T Idiom' 115 PRO47ECTSUP. INTACM QEPGOOICYOT ORC - e•ERUSEOF 7-1S ORIGINK" S AOMBarM • r • I .1VJrJr /IAr.■ I \ ..:WM. viii S. ST. EYE NBUT, BED IN SEALANT S. ST. FENDER WASHER ON OW RUBBER WASHER BED WASHER N SEALANT 6'x6' EPDM MEMBRANE ROOFING SEALANT S. SL HEADLESS HANGER SCREW, SECURE TO PLYWD/VD BUCK REF. (05500) FOR BANNER ANCHOR AMY PRODUCT SOURCE BANNER ANCHOR AT PARAPET COPING 10 REF_ A4.1 SOURCE r=r-0" ROOF HATCH DETAIL REF: A25.742 SAFETY RAILING SYSTEM (07720) . - ROOF HATOI RADIUS T.O. SIDE RAILS POUT LANCER 90 TCP RUNG PUCKS w/ T.O. ROOF 4' x5 1/2''x 12 GA. SR. PL/EIECK CLOSURE AT ROOF HATCH OPINING (Mi. 9DES) BENT CEP ANGLE LAG TO (MEMO 14. MOM 04 1 12 =1-17 • 5' CONC. SLAB REW . W //3 BARS 18' O.C. EACH WAY SEALANT ON 1/2' COMPRESSIBLE FILLER :a, �.: A2f CONCRETE SLAB DETAIL REF.: A2.1 ROOF CURB DETAIL REF_ A2.4 A02 8' I 1AD0ER DETAIL ROOFCURB YY . NAILER AT PERIMETERS i - MEWL ROOFING SYS1131 • SET T.O. SLAB ELEV. TO PROVIDE POSITIVE DRMNAGE AWAY FROM SPEED LIFT SURFACE MUD. SPEED LET (10300) SECURE TO CONC. SLAB 6 ML VAPOR BARRIER ON PREPARED SUB -BASE HVAC ROOFTOP UNIT (R.T.U) (OTHER EMT. S81.) MET. FLASHING OVER MELD. COUN1ERFLASIRIG 18 GA. METAL DECK CLOSURE ROOF OPENING ANGLE FRAME / REF. BET. 07/A6.1 SOURCE 18 112' = 1'-0r• 17"1'4:r 03 far=r$ • CUSTOMER RAMP NOTE: THIS DETAIL SHOWS PETCO STANDARDS FOR A CUSTOMER RAMP FOR SHOPPING CARTS` F THIS RAMP IS MENDED BY THE LANDLORD/LANDLORD ARCHITECT/ENGINEER TO ALSO FUNCTION AS AN ACCESSIBILITY RAMP, N ORDER TO MEET FEDERAL A.D.A. OR STATE ACCESSIBIUTY STANDARDS, THE RAMP DETAILS AND CONSTRUCTION SHALL BE MODIFIED. AND SHALL INCLUDE PROVISIONS MATCHING OTHER ACCESSIBILITY RAMPS FOR THIS SLATE. INCLUDING BUT NOT LIMITED TO DETECTABLE WARNING. PANTED OR CONTRASTING SURFACES. MIND SLOPES. MAME ANGLE SIZES np 0 TO 2 L3x3x1/4' 14x3 2'-0' TO 5'-0' 1/2x5/16' 15x3 5' -00 TO 10'-0' 1/2x3/ OVER 10 CONTACT 14x4x3/8" CLIP TYP_ (4) VERIFY W/ EQUP. SUPPLIER ROOF ANGLE FRAME DETAIL REF_ A25;A02 SOURCE [1' GAUL 1.3 x 4 x 1/4 R 11 4C DOOR ANO E GUIDES u 1,--- ROWN DOOR GAM 6'x1 /4' CONT. JAMB IL9/ 1/2 r Ot&x3'LmosrQC< FULL SID DR EA. ANGLE GAMY. li x 3 x 1/4 ROLLING DOOR JAMB DETAIL REF: 1421 SCARCE 1.511E AND LOCATION OF FRAME OPENING TO BE FURLED TO STEEL SUBCONTRACTOR BY CONTRACTOR R11EREOR F.O;M. 07 H.T.S. 02 3 =rte M 0/ CO 4' CONC. W/ 66 WI.4x W1.4 WYE RENF. MEDIUM BROOM FINISH ON ALL RAMP SURFACES PROVIDE CONC. E.J. 0 RAMP PERIMETER WI 133c 12' DOWELS 16' 0.C. EMBED 6' INTO RAMP CONC. TYP. CUSTOMER RAMP DETAIL REF.: A21 SOURCE: SECURITY BARS ALL ROOF OPENINGS LARGER 1 THAN 12' N EITHER DIMENSION (EXCEPT RT.U.S x • SECURITY BARS PLAN DETAIL REF_ A2.5. A02 SOURCE 5/0' DUI. SR- BARS, MAL SPACING 8" 0.C. EA. WAY, VELD ALL SLAPS AND AT ANGLE FRAME BUTT JOINT REF TO DETAIL 07/A6.1 FOR SIZES OF MOLE FRAME MEMBERS/ REF. MECH. FOR ROOF OPENING SIZES arrete V!3 1 :e� r 4 coast 16 N.T.S. MEM } co .J v� w o U � <? Q o Zco � Z_ Qw z = o� W Ha I-�g WD R o_u) ())rP N a a z 0 w 0 b . fl oo W 6 �z p� 1007 Coo *iron J.tC01sl. 7421 MOM AQ1 amnia comornoPes Apo CORRELATE OLIERSORO POOR 10 MOVONG THE SOAK CEW1°i TAM OR SINGS, SW9iKL MOWRYNOTFY THE osafroace PAY OSCREPOCES o Pv : RIRMKILIMIS PACHUEOCS UP. wwrasaB) aEMoC NICK OR aniut USE is MS CRAMS MOKERS) DETAILS 1 DIFFUSER NECK SIZE SCHEDULE AiR VOLUME NECK SIZE Up to 175 CM 6' Diameter 178 to 275 CFM 8 Diameter 276 to 380 CM 10' Diameter 381 to 500 C 11 12' Diameter 501 to 700 CM 14' Diameter 701 to 900 au 16' Diameter HVAC TREATMENT SCHEDULE Spode Served Season Indoor Design Temp (T 06) Outdoor Air Requrernents Retail Sunnier 75 (a os reqd by code) 0.30 CFM /sq ft Winter 70 (ar as reqd by code) 0.30 CFM /sq ft Pet Areas Surmises 75 (a as reqd by code) 1.0 CFM /sq ft _ tinter 70 (a as regal by code) 1.0 CEit /sq ft Offices Sommer 75 (ar as recd by code) 20 /Per Winter 70 (a as read by code) 20 CFM /perran Pre-Sdes Summer 75 (or as reqd 07 co4e 015 CFM /sq ft tYatter 70 (or as naiad bill code) 0.15 CFM /sq ft • t e HVAC SCHEDULES DIFFUSER & REGISTER SCHEDULE UNIT ID. I MODEL I DESCRIPTION I NOTES CD1 CO2 RG/1Gt TG2/EG2 EG1 FRG/lEG oco WIG/REG 1234 12P 1230 12P 12P 12 -PFF 530 SERIES 01- 530-22 WOK Ceiling diffuser perforated face supply air diffuser with adjustable curved blades. Loy -in. Neck size as noted on schedule Ceiling diffuser perforated face supply air diffuser with adjustable curved blades. Surface mount. Neck size os noted on schedule Ceiling retum /transfer air grille perforated face return air grille. Neck size as noted on schedule Ceiling exhaust /transfer air grille perforated face exhaust or grate. Surface mount. Neck size as noted on schedule Ceiling exhaust air grille perforated face exhaust air grille. Loy -in. Neck size as noted on schedule Ceiling filtered exhaust /relief air grille. perforated face filtered return gnlle with 1' thick filter. Neck size as noted on schedule Concentric ceding diffuser. Side supply air discharge center return air draw. Combination supply and retum air device. Wall transfer ar / exhaust or horizonal bor type grille Size as noted on schedule GAS FIRED UNIT HEATER SCHEDULE 1 1 1 1 1 1 2 1 NOTES: 1. Selections are based on JdcJ Register. Acceptoble alternates Titus. Anemostat, Metdaire, or Price. 2. Selections are based on Rooftop Systems Inc., furnished os port of the Lennox RTU package. GUH 0 UNIT ID. I MANUFACTURER 1 MODEL NO I BTWI I MOUNTING 1 CONTROL I ELECTRIC DATA Kw I-s I 11 I AMPS NOTES Suspended 1 GUH -1 Reznor 1 UDAS -75 I 75,000 1 EMS 1 0.2 1 120 1 1 1 1.9 1 1,2,3,4 NOTES: 1. Mirth spark-ignited _sofety plot and 60' downturn nozzle. 2 Unit controlled directly vio EMS system via factory - installed 24 -volt control transformer. 3. Acceptable alternate manufacturers are Hastings Sterling. or Lennox. Lennox is approved only for 100MBH and up. 4. Vertide combusion oir kit_ ELECTRIC UNIT & CEIUNG HEATER SCHEDULE e UNIT ID. I MANUFACTURER I MODEL NO. I BTUH 1 MOUN7ING 1 CONTROL t tECiRIC DATA NOTES KW Iv its I • I AMPS CUH -1 1 Berko f FFCH -548 I (` 6.300 r ecessed in Cel'n ENS I 2.0 208 1 1 I 9.6 l 1,2,3,4,5 CUH -2 Berko FFCH -558 17,100 e0es9ed In Cel'n� EMS 5.0 208 3 13.9 1,2,3,4,5 NOTES: 1. Acceptable dtemote lndeeco (Ca &tries), or Q -Mark (CDF series) 2. Provide factory- installed 24 -volt control transformer. EC to provide 24 -volt hddmg col control relay. 3. Color shill be white. 4. Provide factory- instoied disconnect switch. 5. Field convert wiring as directed in installation manual for operation as indeated. UNIT ID. I MANUFACTURER 1 MODEL Nor I TYPE Creenheck Creeihedk G8 -091 -4 GB -071 -4 Roof Exhaust Roof Exhaust 1 DRIVE Belt 650 EXHAUST FAN SCHEDULE .75 1 EF -2 EF -3 EF -4 EF -5 EF -6 ACCESSORIES: 1_ Fan shall hove manufacturer supplied roof curb. bockdraft damper, bird and insect screen and electrical disconnect. NOTES: 1_ Acceptable alternate manufacturers are Penn. Cook or Breidert. 2. EC to provide 24-volt holding coil control relay. Creenheck Creenheck Creenhedk Greenhedk CB -071 -4 GB -071 -4 CB -071 -4 CB -071 -4 Roof Exhaust Roof Exhaust Roof Exhaust Roof Exhaust _ Belt Belt Belt Belt Belt 1 4" I R OOCED I soNEs 1 FAN I MOTOR NoTEs HP I• 'WEIGHT' 180 250 150 250 135 _50 .50 _50 _50 .50 1 1 1 1 1 EMS via contoctor EMS via contactor EMS direct 10.3 1556 &5 1556 8.5 1556 5.7 1247 7.0 1401 5.7 1247 1/4 1/4 1/4 1/4 1/4 1/4 120 120 120 120 120 120 1 1 1 1 1 1 85 50 50 50 50 EF CII 1 1 1 1 E'r-1 TAG NO. I -- - - -! - - -- I NOtlIAL SUFFIX FM DX COMM COL DATA CAP. CiX I ESP_ CAPACITY NMI) (TONS) TOTAL 1 OA WAX OA Mw ill. M & TOTAL/SENS. RIU-1 Thru 41 Lennox LGC120S4 RTU -5 Lennox LGA060Ff4 10 4000 5 20001 650 ! 650 NOTES: • firat& monufocturer suppred roof curb & bun-cfar bars. 2. skid sham be furnished with barometric relief dampers, filter rack, hod guard. filters and bkacfor bars. 3. Smoke detectors and stamping tube to be furnftherf by Lennox and factory ir►stdted in the supply aid return air stream. Smote detector remote test /reset station to be kenished by Lennox and field installed in the location shown on the drawings by the CC. Al smoke detector Irking by otters. 4. Unrl shdl be verticd discharge and belt d ROOFTOP UNIT SCHEDULE HEAT um I"em fN OUT 1125 245 1 0.8 129 6/8a1 240 192 0.8 636/47.7 125 100 NOTES (CONTINUED} 5 Vock: a'.ry economizer with outdoor ar hood, GS necessary x619 differential enthalpy contra, and sensors ore factory installed by Le 10L Podcoged L series units shad have factory instarred controls. Instdiig contractor shill install di nears ry Wag and contrds to interface with tt:e EMS system. See HVAC and Decided General Notes as will as notes on P1E1.1 and specf'cotions in the Project Manua. 6. Unit stall have factory irnstdled eonrenierice e'ectriod outlet end 6scanrect switch. COMP FLA Ei.ECTRiC NOTES VOLT /0/Hz �p{T (EACH) HP FAN I I 1" � " 1 1 LBS 7_4 3 460V/3/60 29 35 11.0 1859 .2,3,4.5,6.7.8 9.0 I 2 1460V/3 18 25 10.1 886 11.2.3,4,5.6.7,9 NOTES (CONTINUED} 7_ HVAC units st•.olt be purchased from Lennox Notional Accounts executive Steve Fricke. Telephone 972- 497 -6788 Eiq,ect 8-10 weeks delivery tine. 8. Lennox shall furnish and contractor to install diffuser podcoge oonsistng of supply pferurn, retum plenum. return duct grille; and four way supply step down diffuser with prime coat. Contractor to provide sipports and counectig ductwork aid shall field point per specirroetions. Diffuser package to be Lennoir/RSI product. 9. Provide with Lennox Hurnidrol option far L Series units, including humidity sensor. RR; 0 HVAC GENERAL NOTES 1. AN air moving devices, including but not bided to, air handling units, air condiioning units, and unit ventilators must comply with AMCA Standard 210 and ASHRAE Standard 62. 2. Provide fleable correction on all duct connections to fans and other «1 3. Duct sizes shown are clear nside diimensions. 4. Provide tuning varies in all square elbows, unless otherwise noted. 5. Provide volume damper on each branch We off from duct main and each diffuser take off from brunch duct or main. on 6. Fleable duct corrections to registers, diffusers, etc. shall not exceed 6' 0' in length. 7. Contractor shall cover open ended ductwork with 112 x 1/2' in wire mesh. 8. Unless othenvise noted on the drawings, all mechanical equipment within the contract aids shall be mounted on vibration isolators to prevent the transmission of sound to the building structure. llbration isolators steal be in accordance wish the specifications and on actual weight distnbuuon of the equipment furnished. Deflections shall be noted on the equipment shop drawing submittals. Contractor shall provide al seismic and hurricane resistance provisions required by local code. Where required, provide detaas with calculations signed & sealed by a Structural Engineer licensed in the State_ 9. HVAC snits are furnished nth a smoke detector with sampling titre to be installed in the supply and return air stream as required by local code. Smoke detector ndicator fights shall be visible from inside the budding. HVAC Contractor shall install and 6ecirical Contractor shall wire smoke detectors. 10. Balance al air systems as per specifications. HVAC Contactor shall be responsible to submit one signed and sealed testing and balancing report to the reviewing agency and one signed and seated testing and balancing report to the local budding official prior to project completion. 11. Gas -fired equipment seaec ns are based on alludes up to 2000 feet above sea level equipment selections for altitudes over 2000 feet above sea level shall be ctedred and adjusted if required. 12 Contactor shad provide decal for each rooftop HVAC unit, wilts mriinnrn 4 high reflective letters, to idengy each unit for maintenance purposes. Decal shad be placed on each unit adj ant to the unit power disconnect switch. 13: Ftooftop HVAC units shall be suppled wait coastal package (coil coafin9, painted mss, etc.) when site is located well five (5) Hides of the coast. 14. Contractor shall instal replacement fates furnished by Lennox in each u nil following system startup and after protect completion. 15. Contactor shall startup equipment and test for all fu ncfonaRy (lleating, cooing, ventitafion, etc.) and al stages as a condition of final acceptance of the systems. 16. For projects where ether units odder than Lennox are furnished (by Landlord, for example) or where existing wins are to be reused, HVAC Contractor snap furnish smoke detector System Sensor 10H400ACDCP wit swiping tube and remote IesVreset station RTS451KEY and Bectrical Co ndtractor shad wire same. 17. At the Contractors dec.6on, direct drive exhaust fans may be used where be drive fans are ndcaled, provided that 1) pefoenamoe and characteristics are snider. 2) deed drive fans are provided will a sold state fan speed °entreaer for field adjustment, and 3) changes affecting other centred= are done so at no additional cost to PEi00. 18. To enable temporary cooing or hearing via the return ar sensor, refer to pages 32.1 38'ECRY control parameters. Black 6.01 & &17. Contact be Vesedca at l.ennca lndussies (972) 497.7765 for Anther irisbuction on programming for return ar contreL • HVAC SYMBOLS ? KEY PLAN identifier FDAD SOD 1 A 1 310 - SDAD Description New Ductwork New Ductwork With 1' Acoustical Lining Existing Ductwork To Remain Existing Ductwork To Be Removed Insulated Flexible Duct Volume Damper Fire Damper And Access Door Smoke Damper And Access Door Motor Operoted Damper Equipment Type Equipment Number Cubic Feet Per Minute Connect New To Existing Supply Air Flow Exhaust Ar Undercut Door Duct Smoke Detector 4 Way Ceding Diffuser Diffuser Tog • ' w.. Kee IC" 1TypEI cos 1 Humidistat - Height As Noted REVIEWED FOR CODE COMPLIANCE I APPROVED MAY 2 ': 2001 i City Of Tukwila BUILDING DIVISI 01 Lh 1 r z Ito ir4 a. csaiaimoc 10O%Complo ion I -LOOM. • 7424 a.R! age 1113M% ii1C011t JOe• owaegt 035,111300101110101MD PROADIROMEIRXIK ocommearniESE CUR N 13E ARCM= OF coPi iSORl RIPPRI tunas ulA FIVECrs 1 P_ OR OPER MOP INS 0111.00 aPtoras+m. mono Imo GENERAL NFORNATION AND SCHEDIAES M1.1 r • • ©© 1 1 1. I �. • • 4 1 x 12x10 0 s1 O m © O • 1 Ea © © 17-11 • s• SIN • (I 123112 a • • 1 'MECHANICAL PLAN Mb'F REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 4 2e01 OLy Of Tukwila BUILDING DIVISION • NOTES NOTES FOR THIS DRAWING 1. See structural drawings for exact placement of rooftop HVAC units, exhaust fans, supply air and return air openings and locations through roof. Carefully locate roof top units such that concentric diffusers falls in a structural bay. 2. Refer to anhitectural reflected cell ing plan for exact placement of ceiling diffusers and grilles. 3. Temperature in the Wellness Room must be maintained between 74T and 78°F. 4. Install duct smoke detectors in accordance with notes on Rooftop Unit Schedule and HVAC General Notes. 5. Exhaust fans in open Retail Area are dimensioned so that the equipment is located in close proximity to the store fixtures they are serving. The purpose is to minimize any offsetting of ductwork for cost and aesthetic reasons. Contractor may locate fans up to 12 from location shown to avoid structure and other interferences. Verify with PETCO Project Manager during this process. 6. Unless otherwise noted, all ductwork is rectangular sheet metal. Exposed supply and return ductwork shall be internally fined to within twenty feet (20') from the HVAC unit, while concealed supply ductwork shall be wrapped. Refer to Project Manual for details. 11* Contractor, at his discretion, may use round ductwork with property installed external duct wrap insulation in concealed areas, and may use round or spiral, (intemaly lined where apptcable) ductwork in exposed areas. 7. In exposed areas, roof openings for HVAC equipment shall be baited, where possible and practical, to accommodate the duct openings and no more. the intent being to maintain a neat and aesthetically pleasing finished product with as much of the roof itself intact as possible. 8. Refer to sheet E2.5 for control devices. KEY NOTES (Symbols 0,0 Etc.) 1. Orient Ctkt such that airflow pattem is as indicated. 2. Provide 5' B -vent up bough roof with weather cap. See detail 141M3.2. Terminate not less than SO' above top of unit heater and in no case less than required by detail 141M32. Provide fisted adapter and connection to unit_ Limit horizontal run to a maximum of 2'Or and alit qua duty of elbows to one (1). 3 - Supper four (4) places with 3r8" all thread with vibration isolator from unistnrt spanning bottom cord of joists. Maintain clearances to combustibles as pubtished by the manufacturers. Mount top 1'0' below bottom of bar joists or at 14'0'AFF, whichever is lower. 4. Locate this rooftop unit such that the supply and return ductwork from the are within the walls sraroundi g this area (no exposed ductwork on Retaa side of wall). 5. The rooftop package includes a prefabricated concentric return/supply diffuser for each rooftop unit as shown, type CCD 41, x34 (refer to diffuser and register schedule). Contractor shall fabricate sheet metal duct extension to meet proper outlet height height below steel 15'0' AFF to bottom of ht and of diffuser (max). All diffusers shall be the same height. The HVAC contractor shaa g provide misc. steel (channels. angles, etc.) to support ducts. oikiser, germ as required. Connect nt+sceNaneous steel to bolding g structure in a mariner acceptable to the architect. The HVAC contactor shag adjust the pattern of the supply air outlets as required to provide approximately equal ter quantities and fun coverage of the retai area. If required by field conditions, irregular ax flow patterns or unequal air BOWS may be obtained by closing front vanes at ends of outlets. 6_ 14 x 14 wail transfer gale. Mount bottom at 14' -2 AFF. 7. 10r x10" wall transfer guile. Mount bottom at 14%7 AFF. KEY PLAN 1 01 NOSCPLE J Hio 1 CC 0 CC 0 0 mis IX Zs o110ll,uiae 10011,02mpkion 1100106 00811110=Com SWIM MOW MOM 001€111018:1NID • 3881E 011181 1011SPAOri 10 PnbYDNei11E11l8C 001112011111113E I�31et1 14101IP1LYrloT y 1FEA:104T CTOF o coPrresEgaalrls 1,100MranIZED INEIRIODuCriall CROMER UBEOFIles oidelRlassPNOleEr®t 'wow sac MECHANICAL L PLAN M2.1 • 1 r LARGE SCALE SUPPORT AREA PLAN REF.: ligiall 05 1 =rte Note Rear pis: rir Wd hstaot arle tagan LARGE SCALE BIRO HABITAT PLAN REF: awl 04 NO SCPLE _ 00 • • Cdlectiam box • ntea to 41 i I 1 ISI I IPA / -- toehne.u,lc d Co►nea tom . emit of t _____ (4) of by �� ts 'L goimm 10• Spiral e+r+cug6 of decor doh centered. ensure power cod spridder �a tight . to 6 tac BIRO HABITAT ELEVATION REF.: WM !err side Kr Met Lamer (rWai For 4.) LARGE SCALE GROOMING HVAC PLAN I 07 REF.: 0211121 1 ut• =1'-0r 03 LARGE SCALE HABITAT PLAN PIO SOLE REF.: 117111121 NOTES IiEF.: 02 KEY PLAN NOSCME REF: NOTES FOR THIS DRAWING 1. Refer to mechanical schedules for applications of rooftop HVAC unit discharge packages. 2 Maintain minimum 10'-0 between outside air intakes and any exhaust outlet or plumbing vent. 3. Refer to sheet E2.5 for control devices. 4. All ductwork in areas with suspended ceilings shall be concealed above ceiling. 5. Contractor may at his discretion, use round duct of equivalent size in lieu of rectangular in concealed areas. Duct shall be insulated as specified. KEY NOTES (Symbols 00 Etc.) 1. 16' round duct up to EF on hoof. 2. Grille with hinged frame for integral, cleanable filter. 3. 4' diameter rigid galvanized dryer vent, in wall space, through roof with vent cap with backdraft damper. Provide (n- O-Vate Technologies, model 425 Dryerbox, in center of the dryer at 30' AFF to the bottom of the box. Install per appliance manufacturers instructions and listed requirements. Use straightest duct nuns possible to outside, 25' equivalent length maximum, no screws in airstream. 4. 3 PVC flue vent for gas water heater and 3' PVC combustion air intake down to water heater. Maintain separation per manufacturer's specifications. Note this model is certified only for PVC. CPNC or ABS vent material. 5. 8 spiral from roof exhaust fan to below top of plastic tubing of animal habitat fixture. Mere required to avoid conflict, provide minimal offset in duct just below bar joist Return to site after habitat is installed and provide 4 flexible exhaust duct down prefabricated plastic tubing to air distrbution sphere and air distribution box Tubing and sphere provided by PETCO vendor. Air demon box by Mechanical Contractor_ Mechanical Contractor to coordinate installation with PETCO vendor. See detail 02/M3.2_ 6. 4 exhaust from air distribution box in plastic air distribution sphere to habitat inside plastic tubing. Typical for all four (4) habitats. Contractor to provide 6 4 reducing collar from each habitat. Tutting provided by PETCO vendor. Mechanical Contractor to coordinate installation with PETCO vendor. Use equivalent length duct in all legs of habitat for inherent balance of air system. 7. Coordinate the location of the exhaust duct with the Ownefs furnishings and other trams. Refer to architectural plans for designated, m area for exhaust duct and other trades' work. 8. 10' round duct up to EF on roof. 9. 10' round duct down from EF on roof, to bird habitat. 10. Grooming area rooftop unit humidity sensor furnished by Lennox, installed by Mechanical Contractor. Mechanical Contractor is responsible for receipt and safe keeping of humidity sensor until ready for installation. . Provide 4-wire shielded twisted cable from tumidity sensor to REU control board and connect per manufacture's installation iron. See sheet EMS1.1 for add information. 11. As part of the unit startup, Mechanical Contractor shall make adjustment at the rooftop unit control board to change the humidity set point from the factory setting of 60% to the preferred set point of 50%. Contact Vince %%sdo at Lennox Industries (972) 497 -7765 for instruction on programming the humidity set point. RBA� F.°11 c n v�o i v. ItDt' o5� - t0 • • 0 • • • • f 3 osaRRIOOle 100%0xurisfonh -ccor. • 7424 oae PFRpPi Rae NUN OCIIRRICERISEMUS 00110MONSAND CO/RELAX o DINS PRIOR of AREDNT,#Sec INVIGR NO SIMI. PROr.'R.y- IwY THE IIROff Ter ay WPr SIGeor XRPRIRIARRIIS ARCihrison UP_ urSIUMroaREDrSEMoouath a OROTHE RtSECEr r RRE IRE MECHANICAL PUNS AND OEMS M3.1 1 • • Vertical Vent Terminal /Combustion Air Inlet Assembly (Option CC2) } (aeta ' , > ('pbssdiea .Air Pipe A %e. lifl)e esbeesi) Tannic[ 4— - -le 1 1 1 AdsPler 1 t 1 REAR VIEW ELM i Ceseketke ` Airbeleis idea t' r all seat ere_ Sadba et guy eistissl 1 -Nsli 1 ! Veal Pipe seal um ;None seal & iprre4 w hh MA AS. V1a1tr ei* PFpe A1nd a seal rue sin see* Shea 6'(I a) treat de box. ROUND VOLUME DAMPER DETAIL I 05 Walt or Adjoining Building Sizes 75-225 4 ft (1.2M) Minimum Sires Lail -M1 6 ft (1.811) Minimum Flashing (field - supplied) 2' (51m nal if roof is combustible Attach box to roof "With brackets. `Inlet air cap mist beat least 6" (l52mtn) higher than anticipated snow depth. REF: 021121 r Tip` REF: 01132 r 5. 1 1. use 20 gouge sped meld SIDE VIEW FLUE THROUGH ROOF DETAIL J AIR DISTRIBUTION BOX DETAIL 9 3i8 (238min) 12" (34Satm) \linbnum Cold Climate NOTE: In geographic auras where the design ambient is -10°F (23 )Or lQtns minimum height is 23"(61 Onun). 1 11' (279mmm) 1 f1 t i =i8" f (457mm) 4 ft (1.2M) i Aliaimur Maumunt i (Top ofBmk)1 Concentric .Adapter Bet 1 14 NO SCALE Factay Mounted Disconnect Roof Curb 14' IFigh REF: amLA .I Span Aluminum Roof Ey/muster Prefabricated Roof Orb Steil Frame (By Structural Steil Contractor) NO11E` 1. Secure exhaust fan unit to curb ROOF -TOP EXHAUST FAN DETAIL I 18 REF: I NO SCALE Conn ectia a Duet / And Location Verify Size Cawhrns (r N4 Plenum Rectangular Duct tifith 2 Thick Duct Liner khsubtion IIO1ES FOR OFTAltS 13 de 14: 1_ Secure HVAC urns to curb. 2 See ArchRecturd plan for securing aids to roof and roofig ot Curb detail 3. Where required by local code. provide p .d condensate to approved receptor. usag copper or UV resistant PVC. or point per specifications. RTU PACKAGE HVAC UNIT DETAIL I 13 • NOSCALE 1101E Exhaust fon instiller to be on Me wrili materials for find connection to habtot prior to odd of Subsea. Ibn-:htre stoic pressure loss o dud by the ariourht of turns and links inside the sphere. 4' Eirk ast clod fie widiied cud installed castroda , inside pfestac lobe provided by PE1C0 vendor. to blind baeiaats. Provide when, dove -. See *WI 06/1132 typical ion all bur bobitots. FsSaust 33 Olt from cab hcbbot_ Curb Mounted Eidhaust Fan Transition (as Required) Dirt Leg Roof Pitch Canvas Fkuable connector (Tip.) Duct fo ce - Detol ( Roof Top is iJ Unit Regulator Shut-Off Votve Gas Line See 02/P2.1 For Contiwotian. (Uinirnan of W 4") Plenum Or Duct Height Minus r Use This Fitting There Spin -In Fitting is Lager Than Duct Or Plenum REF.: 071121 Factory Mounted Disconnect Roof Curb 14' WO Curb Alternate Tapered Top-In Fitting BRANCH DUCT TAKE -OFF DETAIL Nuevo Indicated On Pions. Duct Runout With Vbkane fxfroctor On Supply Connection Use appropriate cable or all-threod supported from unietr% t seardyy fastened to roof sbucttre. Ridded Doan H.V.A.C. Unit e%um Or Duct Los -Kett L Fitting Attach 1tith Sheet Metal Sae,es And Seal With Medan Pressure Duct Sealer Rigid duct With 1 Thick Duct liner Inhalation Canvas Connector Flexible )p.) Ope Diffuser Concentric Diffuser See M2.1 Infam Height RTU PACKAGE HVAC UNIT DETAIL I 12 NOSCALE REF.: OZd121 8• Spiral exhaust duct furnished and installed by contractor. inside plastic tube provided by PETcO vendor. connected to duct above in pot spore to roc othoust fun. Provide square -to -round duct (motion. Piratic enclosure. 2 halves. prodded by PETOO vender. cir distrabatuon born_ fabricated add instded by medhadicd eoatiroctior. Bag shoal be ehfhousted to fr duct on the tap *cm bcbabats and four sides See dotal 04/113.2. Plastic enclosure. 2 bafree% provided by PETCO verda,r. SMALL ANIMAL HABITAT DUCT DETAIL REF: MA31 ol Manual Volume Damper Breach Duct -See Floor Plans For Size And Routing Cosical Shaped we Modular WWI Flex Sin - tirandi Duct-See Floor Plans For Trot And Routing Roof Top Unit (Ty.) Reghdotor swt -Off Valve Gas Line See 02/P2.1 For Continuation. Dist Leg Roof Pitch 17 DUCT HANGER DETAILS NOSCALE CO[ EE CO NCE APPROVE) MAY % .1 200I • BU REF.: Ay Of TUkwiL: WING DITIS� " CONDENSATE TRAP DETAIL REF: 3.r (� " r% lide Steel Metal Strap Scare Wire To Structure Ab ne KEY REF.-. Rirjd Rand Oboe °Reser Or Qtle Extend Wm. 3'-d' Past Downhill Side Of Unit Vent 1 DIFFUSER CONNECTION DETAIL Secure to structure dove As recommended by SMACNA. Galvanized iron strap or akrnin um strap. tan under duct minimum 1'. Rivet or bolt to underside of duct Sheet metal screw. rivet Cur bolt to both aides of duct. W re a) Support from unlslrut spanning top chord of bar phis. b) Use duct strops with bolt clomp to support round ductwork. For bracing angles see notes. Nut and washer ot end of rod. 11 1' Copper (PVC %here Permitted) 1.1111111 aeon Out 16 NO SCALE 11 NOSCALE NOSCALE 01 NOSCP E 1 onumROt 1005LOampieks DAZE 11130106 1iv Der11•11t JFW OQS1I IpNSAPO OETANED Tf 3SE OFUNteak AlosltAtu.moavarltol FY THE MOM= oFAUnr oattlritr real CRC llIM QE CF11ta MECHANICAL OE TAI M3.2 1