Loading...
HomeMy WebLinkAboutPermit M07-059 - TUKWILA COMMERCE CENTERTUKWILA COMMERCE CENTER 631 STRANDER BL M07 -059 Parcel No.: Address: Suite No: Tenant: Name: Address: 0223300020 631 STRANDER BL TUKW TUKWILA COMMERCE CENTER 631 STRANDER BL , TUKWILA WA Owner: Name: CALWEST INDUSTRIAL PROP Address: C/0 DELOITTE & TOUCHE LLP , 2235 FARADAY AVE #0 Contact Person: Name: PETER CRELLEY Address: PO BOX 33370 , SEATTLE WA Contractor: Name: PRO STAFF MECHANICAL INC Address: PO BOX 33370 , SEATTLE WA Contractor License No: PROSTMI072NG DESCRIPTION OF WORK: REPLACE (1) EXISTING COOLING TOWER LIKE- FOR -LIKE Value of Mechanical: $18,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: httn: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 1 0 0 0 0 0 * *continued on next page ** M07 -059 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 361 -0071 Phone: 206 -361 -0071 Expiration Date: 06/30/2008 Steven M. Mullet, Mayor Steve Lancaster, Director M07 -059 04/10/2007 10/07 /2007 Fees Collected: $361.78 International Mechanical Code Edition: 2003 Boiler Compressor: 0 - 3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP/1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 04 -10 -2007 Permit Center Authorized Signatur I hereby certify that I have read an governing this work will be complie • , "' ther specified herein or not. doc: IMC -10/06 Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us .11 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: M07 -059 Issue Date: 04/10/2007 Permit Expires On: 10/07/2007 Date: UI 1 10 permit and know the same to be true and correct. All provisions of law and ordinances The granting of this permit doe not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo � of work. I am authorized to sign and obtain this mechanical permit. 9 / � Si tore: Date: /l oft) ? This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspendec or abandoned for a period of 180 days from the last inspection. M07 -059 Printed: 04 -10 -2007 Parcel No.: 0223300020 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 631 STRANDER BL TUKW TUKWILA COMMERCE CENTER PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. M07 -059 ISSUED 03/23/2007 04/10/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 7: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 M07 -059 Printed: 04 -10 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond - 10/06 Date: 711vp M07 -059 Printed: 04 -10 -2007 CITY OF TUKIlkA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http.11www.ci.tukwila.wa.us Site Address: 6 31 STRAN DER, R L VD. Tenant Name: TIA kW IL—A— CU tKME(Lt..E C'ENTEE2 New Tenant: ❑ Yes '� � No Property Owners Name: 1 Mailing Address: 6'31 S?1ZANDER SLV D. t , do a co ttaet vhen yoas permit is ready •to be Name: PETE C 4 E Lt `1 Day Telephone: 206 - 31,1.-007) Mailing Address: P. O. gUx 33370 SPF[TLE 1"► A '33 City State zip E-Mail Address: PErE12@ P a- STAFFMEC NA-All CA L LUYY1 Fax Number: 206 — 3 61 —O 7-4— aniust<;berct .. ............................... Company Name: Mailing Address: Company Name: Mailing Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print" INFORMA ............................... .............................. i g 4) for P hi Contact Person: E-Mail Addres Fax Number: Co .r Registration Number: Expiration Date: StAt•rc Ca 7�k w llI City Contact Person: King Co Assessor's Tax No.: O233O OD 2-0 Suite Number: N/A Floor: ON 6R0w O City E-Mail Address: Fax Number: Q: Wpplicati . - ....- Applications On t;nev -2006 - PamitApplication.doc wA 99,106 state State Zip Company Name: Mailing Address: State Zip hone: Page :UnitType: Unit Type: ;Qty . Unit:. �'Pe C�ly : 'B+uIerLCompFessar.. Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 111 BTU Furnace>100K BTU Evaporator Cooler I Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL CONTRACTOR INFORMATION Company Name: Peo - STA FP M scN- PrN1 CAL IN L., Mailing Address: eo. 3cpC 33370 s, - rYLE i j ciPrK3 City State zip Contact Person: ?£TE12 CSZE Y Day Telephone: Z0t —3(,1 —0071 E-Mail Address: PETER. e PRO STPIFFMFCH AIU IC 141-• COI Fax Number: 206 --361- Contractor Registration Number: PQ.0 STM I U 71 N 6 Expiration Date: 6 Valuation of Mechanical work (contractor's bid price): $ 19,000 Scope of Work (please provide detailed information): /z EPL41-C-E (1) £X / 5 T /NC? COU Ll /U G 77, Ems, L /kE - RJR-- Li Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement / K Fuel Type: Electric Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q: ardie 1 ' ns- AAPUcanons On t:au -woe - Permitnyplicanoa.doe Revised: 9-2006 bh Page 4 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ` ► , OR ."I RIZED AGENT: Signature: % Date: 3113/ 07 Print Nam . l - L 040 Day Telephone: ZO ( - 36 I - 007 1 Mailing Address: F.6. T1/4) •370 6EA City Date Application Accepted: t ole__ Q Wppliation.Tmn.Applicatione On line 3 -2006 - Permit Apptinson.doc Revised 9-2006 bh wA `' 133 Zip Date Application Expires: Staff Initials: (....1 Page 6 of 6 i Receipt No.: R07 -00426 Payee: PRO -STAFF MECHANICAL, INC. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0223300020 Permit Number: M07 -059 Address: 631 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 03/23/2007 Applicant: TUKWILA COMMERCE CENTER Issue Date: Initials: JEM Payment Date: 03/23/2007 01:47 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 10180 361.78 Account Code Current Pmts 000/322.100 295.42 000/345.830 66.36 Total: $361.78 Payment Amount: $361.78 m 'j3/23 7 } T' N doc: Receiot -06 Printed: 03 -23 -2007 Proms / ? /1 / ./f7O rirni/e-C Type of Inspection: /=i.t/ 7 / Address: .3 / ...5 1 4 4dr-, .6/_— Date Called: Special Instructions: / / / Date Wanted: 7 -- // d 7 6.m. Parr Requester: Phone No: 7 5 - 5 3 /9 1e 7 - -0SS INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 . 6)431 -3670 I spector. pproved per applicable codes. Corrections required prior to approval. COMMENTS: ? /&f 4 m v,y term / 4 ,ito INSPECTION RECORD Retain a copy with permit 1 4 •. EINSPECTION FEE REQ ED. Pri to inspection, fee must be al t 6300 Southcenter Blvd., Su e 100. ll the schedule reinspection. (Receipt No.: 'Date: Date: PROJECT w ANDOVER PARK TRACT 2 .. CONTRACTOR Pro Staff Mechanical LOCATION Tukwila, WA , ._ r ? I$:ilN TO Ij REp s ,,.c 3290 146th Pl. S.E. / Bellevue, Wash 98007 (425) 562 -1150 (425) 562 -5123 fax 1. Galvanized Steel Construction 2. PVC Drift Eliminators 3. Seismic Zone 4 UBC Unit Anchorage 4. Electric Emersion Heaters and Controls 5. Mechanical Float Valve 6. Mechanical Vibration Cutout Switch 7. 7.5HP Inverter Duty Fan Motor SUBMITTAL EQUIPMENT MANUFACTURER OPEN COOLING TOWER BALTIMORE AIR COIL P: FILE Copy \ P t No. Representative: Included with the Cooling Tower are the following options: Matthew Adkins /AD Date of Submittal: 3/14 /2007 REVIEWED FOR CODE COMPLIANCE A nPo FD MR a 6 x001 OT 1�ifidil� WILD NG DIVISION CRY OF MAR 2 3 2007 PERMIT CENTER Submittal Information Equipment Summary BAC Terms and Conditions of Sate • CTi Certified Thermal Performance Mechanical Specifications • Steel Panels and Structural Members are Constructed of Galvan Steel Sound Data • Polyvinyl Chloride (PVC) Drift Eliminators • Non - Corroding PVC Film Fill Material with a Flame Spread Submittal Drawings/Diagrams Rating of 5 Unit Print - Right Hand (BAC -9105 A) • Side Outlet Pump Suction Connection Steel Support (BAC- 13238A) • Seismic Zone 4 UBC 1997 Unit Anchorage Heater Location (BAC -9144 A) • Electric Immersion Heaters Sized to Maintain +40 °F water Heater Wiring (BAC -6988 B) at a OF Ambient with Electrical Requirements Matching Vibration Cutout Switch Location (BAC- 11490A) Fan Motor(s)' Vibration Cutout Switch Wiring (BAC- 17491A) • Electric Immersion Heater Controls • Mechanical Float Valve Assembly • Mechanical Vibration Cutout Switch See Mechanical Specifications & Drawings for more detail. .Miffed Your P. O. Number. BALTIMORE AIRCOIL COMPANY Submittal Data Form Sold To: Washington Air Reps 3290 146th Place S. E. Suite A Bellevue, Washington 98007 Certified Capacity: Fan Motor(s): CC: Washington Air Reps Inc. Project: Engineer Representative: One (1) Model VT8 -651J Cooling Tower Unit M Information is Per Unit Washington Air Reps Inc. March 14, 2007 Our B.A.C. Number. U070805601 Andover Park Tract 2 — Tukwila, Washington 210 USGPM of Water from 90 °F to 80 °F at 70 °F entering air wet bulb and 5.07 PSIG of total (static lift + spray) pump head from the unit base. One (1) 7.5 HP fan motor totally- endosed, fan - cooled (TEFC), inverter duty, suitable for 200 volt, 3 phase, 60 hertz electrical service. Fan drives are based on 0 inches ESP. NOTE: Inverter Duty fan motors, furnished In accordance with NEMA Standard Mg.1 — Part 31, are required for applications using variable frequency drives for fan motor control. Corporate Headquarters: P. O. Box 7322, Baltimore, MD 21227 — Tele: (410) 799-6200 / Fax: (410) 799-6416 Thank you for your order. Further processing of your order is contingent upon receipt of approved submittals. Early release is necessary to meet your project requirements. Current Rigging and Installation Instructions, as well as Operating and Maintenance Instructions, are available at our website: www.batiimoreaircoil.com. Project: Customer: Purchase Order No.: Engineer: Model: B.A.C. Serial No.: Fan Motor: CTI Certification: Baltimore Aircoil Company Mechanical Specifications 03/14/2007 Andover Park Tract 2 Washington Air Reps One (1) Model VT0 -65/J Cooling Tower Unit U070805601 All Information is Per Unit S Unit Type: Factory- assembled, counterfiow, forced draft design cooling tower. Quality Assurance: Each unit is manufactured under closely- controlled conditions using standardized parts to ensure each unit is built precisely to the same high - quality design and construction standards. The design, manufacture, and business processes of Baltimore Aircoil Company are ISO 9001:2000 certified. Unit Efficiency: The cooling tower(s) complies with the energy efficiency requirements established by ASHRAE Standard 90.1 -2001. One (1) 7.5 HP fan motor: totally - enclosed, fan - cooled (TEFC), inverter duty, suitable for 200 volt, 3 phase, 60 hertz electrical service. Inverter Duty fan motors, furnished in accordance with NEMA Standard Mg.1 — Part 31, are required for applications using variable frequency drives for fan motor control. The thermal performance is certified by the Cooling Technology Institute in accordance with CTI Certification Standard STD -201. Materials of Construction: All structural steel components are constructed from G -235 (Z700 metric) hot -dip galvanized steel. The edges of the hot -dip galvanized steel components are given a protective coat of zinc -rich compound. Circular access doors provided for interior inspection, deaning, and adjustments are constructed of G -235 (Z700 metric) hot -dip galvanized steel and are held in place with phenolic knob screws. The heat transfer casing section(s) is (are) removable from the pan/fan section to facilitate rigging. Corporate Headquarters: P. O. Box 7322, Baltimore, MD 21227 — Tele: (410) 799 -6200 / Fax: (410) 799 -6416 The centrifugal fans and motors are located in the dry entering airstream beneath the sloping side of the pan. Fan discharge cowls, constructed of G-235 (Z700 metric) hot-dip galvanized steel, are provided on each fan. They extend within the pan to protect the fans from falling water. G -235 (Z700 metric) hot -dip galvanized steel fan guard screens are provided. A hollow steel fan shaft, protected with two part epoxy, with bearing journals at each end is utilized. Solid polished steel journals are coated with a rust preventative. Self- aligning, heavy -duty, grease - packed ball bearings with eccentric locking collars are furnished at each end of the shaft. V belt sheaves, selected for 150% motor nameplate horsepower, are mounted and aligned at the factory. The fan(s), fan shaft(s), bearings, mechanical equipment support and fan motors are warranted against defects in materials and workmanship for five (5) years from date of shipment. Drift Eliminators: Wet Deck: Water Outlet: Basin Heaters: Drift eliminators are constructed of polyvinyl chloride (PVC), and are removable in easily handled sections. They impart three distinct changes in air direction to effectively strip entrained moisture from the leaving airstream with minimum air resistance. Serpentine polyvinyl chloride (PVC) BACount® Wet Deck Surface is impervious to rot, decay, fungus or biological attack and has a flame spread rating of 5 per ASTM Standard E84 - 77a. Wet deck is suitable for a maximum entering water temperature of 130 °F(54 °C). The process water is distributed over the wet deck surface via a spray header with schedule 40 PVC removable branches with large orifice plastic spray nozzles which are held in place with snap -in rubber grommets. A pipe stub connection(s) of a metal compatible with the cold water basin material and appropriately sized for design flow is provided. A large area lift out strainer screen with anti - vortexing hood matching the cold water basin material of construction is included to prevent air entrainment. Anchorage: When supported as recommended, the unit has anchorage to resist wind loads up to 30 psf (146.6 kg/m "2) acting on the full vertical projected area with 16 psf (78.1 kg/m "2) acting simultaneously on the full horizontal projected area or seismic forces of 161% of the operating weight acting in the horizontal direction, and 24% of the operating weight acting in the vertical direction applied at the center of gravity. Loads are appropriate for Seismic Zone 4 assuming an Importance factor of 1.0, and soil profile SD, and rigid mounting to the supporting structure per the 1997 Uniform Building Code. A minimum number of high - watt- density electric immersion heater elements, sized to maintain +40 °F (+4 °C) basin water at 0 °F ( -18 °C) ambient with a 10 mph (16 km/h) wind speed, is provided. Electrical requirements match fan motor. Wring is not included. Basin Heater Controls: An electric immersion heater control package, including thermostat(s) and low water cutout switch(es) or probe(s), is provided. Disconnect switch, contactor, and wiring are not included. Corporate Headquarters: P. 0. Box 7322, Baltimore, MD 21227 — Tele: (410) 799 -6200 / Fax: (410) 799 -6416 Basin Water Level Control: Bronze make -up valve with unsinkable polystyrene filled plastic float arranged for easy adjustment. The make -up valve is suitable for water supply pressures between 15 psig (103 kPa) and 50 psig (345 kPa). Vibration Cutout Switch: Fan system is provided with an appropriate number of vibration cutout switches to limit collateral damage to the unit in the event of a catastrophic fan failure. The vibration switch(es) is mechanically tripped with a frequency range of 0 to 3,600 RPM and trip point of 0.2 to 2.0 g's. No input power is required. Switch rating is 10 amperes at a maximum 480 VAC, and 1/4 ampere at 250 Vdc. Corporate Headquarters: P. O. Box 7322, Baltimore, MD 21227 — Tele: (410) 799 -6200 / Fax (410) 799 -6416 Sound Power (dB) Octave Band Center Frequency (Hertz) Lw 5ft 63 r N CO C U, w P O (OW (0 (0(82 125 A-wgtd 250 55 500 U, 1000 2000 4000 8000 End Lp Sound Pressure (dB) Octave Distance Band 5ft 50ft r N CO C U, w P O (OW (0 (0(82 881` 7$474; A-wgtd 69 55 Back Lp Sound Pressure (dB) Octave Distance Band 5ft 50ft r NM V' It) 1OP tMO tn'iO433 iX e�i 1�i 1�r 1�e 1gi a � A-wgtd 70 54 Top Lp Sound Pressure (dB) Octave Distance Band 5 ft 50 ft .- C\ CI I11 40fsM 001 ° n CD ID (0 iX e�i 1�i 1�r 1�e 1gi a � A-wgtd 74 57 End Lp Sound Pressure (dB) Octave Distance Band 5ft 50ft rN of u) CO P CO A-wgtd 69 55 Air inlet Lp Sound Pressure (dB) Octave Distance Band 5 ft 50 ft r NMV' 10 (OF(0 A-wgtd 75 58 Baltimore Aircoil Company Sound Rating Program, 2/8/2007 Release Series V VTONTI Model : VTO -65-J Total Fan Motor Horse Power : 7.5 HP Fan Speed & Total Fan Power Used : Full Speed, 7.5 BHP Accessories : None Octave band and A- weighted'sound pressure levels (Lp) are expressed in decibels (dB) reference 0.0002 microbar. Sound power levels (Lw) are expressed in decibels (dB) reference one plcowatt. Octave band 1 has a center frequency of 63 Hertz. COPYRIGHT 1991, BALTIMORE AIRCOIL COMPANY BAC -9105 A 15. 20 3/8" < . MAKE f e •u�; OW I > M u r I 1 j 4 WATER OUT M 2 DRAIN e " a 2 1/4" — CO CO 013 4 1/8" -- "� 17 1/4" co N co cV 3' -4 3/4" r— i x--30" 3' -11 1/2" -- NOTES; 1. ALL DIMENSIONS ARE IN FEET AND INCHES. WEIGHTS ARE IN POUNDS. 2. UNLESS OTHERWISE INDICATED ALL CONNECTIONS 3 INCHES AND SMALLER ARE MPT AND CONNECTIONS 4 INCHES AND LARGER ARE BEVELLED FOR WELDING AND GROOVED FOR VICTAULIC CONNECTION. 3. FOR SUPPORT REQUIREMENTS, REFER TO THE SUGGESTED STEEL SUPPORT DRAWING. 4. PRE — FABRICATION OF FINAL CONNECTING PIPEWORK IS NOT RECOMMENDED. 5. DO NOT SUPPORT PIPING FROM COOLING TOWER. ALL NECESSARY PIPE SUPPORTS ARE TO BE SUPPLIED BY OTHERS. MODEL NO. VTO -65/J VTO -75 —K VTO -78 —K VTO -88 —L APPROX. SHPG. WEIGHT 2000 2010 2130 2190 APPROX. OPER. WEIGHT 2580 2590 2710 2770 B.A.C. ORDER NO: U070805601 DATE: 03/14/07 y HEAV. SECT. (PAN) 1070 1080 1080 1140 A 8' -1 7/8" 8' -1 7/8" 9' -7 7/8" 9' -7 7/8" H 9' -0 1/8" 9' -0 1/8" 10' -6 1/5" 10' -6 1/8" BALTIMORE AIRCOIL COMPANY COOLING TOWER DRAWING NUMBER: BAC -9105 A C MODEL NO. DIMENSION * (SEE NOTE 3) A B VTO -12 -E THRU VTO-28-H 45 3/8 24 5/8 3/32 VTO -32 -H THRU VTO -57 -K 45 3/8 59 1/2" 3/16 ► � -J THRU VTO -88 -L 45 3/8 68" 5/16 VTO -102 -L THRU VTO -116 -M 45 3/8 104 3/4" 3/8 VTO -132 -L THRU VTO -176 -0 54 1/4 104" 3/8 BAC- 13238A 20050 Minors NrcoA Compaq. M Rights heaved. 1 NOTES; 1. THE RECOMMENDED SUPPORT ARRANGEMENT FOR VTO UNITS CONSISTS OF TWO PARALLEL I -BEAMS EXTENDING THE FULL LENGTH OF THE UNIT. SUPPORTS AND ANCHOR BOLTS ARE TO BE DESIGNED AND FURNISHED BY OTHERS. 2. ALL SUPPORTING BEAMS ARE TO BE FLUSH AND LEVEL AT TOP AND MUST BE ORIENTED RELATIVE TO GAGE LINE AS SHOWN. 3. RECOMMENDED DESIGN LOADS FOR EACH BEAM SHOULD BE 657. OF THE TOTAL UNIT OPERATING WEIGHT APPLIED AS A UNIFORM LOAD TO EACH BEAM. BEAMS SHOULD BE DESIGNED IN ACCORDANCE WITH STANDARD STRUCTURAL PRACTICE. ThE MAXIMUM ALLOWABLE DEFLECTION OF BEAMS UNDER THE UNIT SHALL BE (REFER TO CHART) OF AN INCH. 4. ALL MOUNTING HOLES ARE 7/8 INCH DIA. AT THE LOCATIONS SHOWN. 5. IF VIBRATION ISOLATORS ARE USED, A RAIL OR CHANNEL MUST BE PROVIDED BETWEEN THE UNIT AND THE ISOLATORS TO PROVIDE CONTINUOUS UNIT SUPPORT. ADDITIONALLY THE SUPPORT BEAMS MUST BE DESIGNED TO ACCOMMODATE THE OVERALL LENGTH AND MOUNTING HOLE LOCATION OF THE ISOLATORS WHICH MAY DIFFER FROM THOSE OF THE UNIT. REFER TO VIBRATION ISOLATOR DRAWINGS FOR THESE DATA. B.A.C. ORDER NO: U070805601 DATE: 03/14/07 AIR INLET SIDE B BALTIMORE AIRCOIL COMPANY OUTLINE OF UNIT v (4) 7/8 MOUNTING HOLES SUGGESTED STEEL SUPPORT: VTO SEISMIC ZONE 4 UBC 97/30 PSF WIND DRAWING NUMBER: BAC- 13238A MODEL NO. NO. OF HEATERS TOTAL HEATER (kw) 0' —20' VTO -12 —E THRU VTO -28 —H 1 2 2 VTO -32 —H THRU VTO -57 —J 1 2 2 • VTO -65 —J THRU VTO -88 —L 1 2 3 VTO -102 —L THRU VTO -116 —M 1 3 5 COPYRIGHT 1991, BALTIMORE AIRCOIL COMPANY BAC -9144 A NOTES; 1. OMIT THE 1" FPT CUTOUT LOCATION WHEN AN ELECTRIC WATER LEVEL CONTROL PACKAGE IS USED. THE LOW WATER CUTOUT WILL BE FURNISHED AS PART OF THE ELECTRIC WATER LEVEL CONTROL PACKAGE. 2. HEATERS: SUITABLE 200 VOLTS, 3 PHASE, 60 HERTZ 0'F AMBIENT TEMPERATURE END OPPOSITE PIPING CONNECTION RIGHT HAND UNIT SHOWN LEFT HAND UNIT MIRROR IMAGE B.A.C. ORDER NO: U070805601 DATE: 03/14/07 THERMOSTAT BALTIMORE AIRCOIL COMPANY 1" FPT CUTOUT (SEE NOTE 1) 1/2" FPT THERMO. PROBE ELECTRIC HEATER PACKAGE DRAWING NUMBER: BAC -9144 A A COPYRIGHT 1985, BALTIMORE AIRCOIL COMPANY BAC -6988 B DISC0NNFCT SWITCH FUSE MAGNETIC CONTACTS (BY OTHERS) (BY OTHERS) (BY OTHERS) ■ y (WIRE MULTIPLE HEATERS L1 - 1 b- -0 - o-' 1 1 - - - -\ IN PARALLEL) I C1 U -o i `4:)- -0 = o- �J L3 -o `o- - {1- 0 N r HEATER CONTROL POWER SUPPLY 1 H - - - - - - �] - , -fl_a - mdla amain B1SE MICH CONTACT -N.Q. (BY OTHERS) (BY OTHERS) SPRAY WATER PUMP (BY OTHERS SEE NOTE 1) B.A.C. ORDER NO: U070805601 DATE: 03/14/07 LOW WATER PENN F -63 (BY BAC) II IIC ci — — THERMOSTAT 1010 PENN A19 -ANC MAGNFTIC CONTACTOR (BY BAC -SEE NOTE 2) (BY OTHERS - SEE NOTE 4) NOTES: 1. INTERLOCK IMMERSION HEATERS WITH CIRCULATING PUMP TO DE- ENERGIZE HEATERS WHEN PUMP IS RUNNING. 2. CONTROL THERMOSTAT IS TO BE SET FOR 40' F. DO NOT SET THERMOSTAT LOWER THAN 40' F. 3. BROKEN UNES INDICATE COMPONENTS AND WIRING TO BE SUPPUED BY OTHERS. 4. CONTACTOR, FUSE PROTECTION AND POWER SUPPLY WIRING ARE TO BE SIZED TO MATCH HEATER REQUIREMENTS. WIRING MUST COMPLY TO APPUCABLE CODES AND ORDINANCES. BALTIMORE AIRCOIL COMPANY ELECTRIC IMMERSION HEATER PACKAGE THREE PHASE ELECTRIC HEATER WIRING DIAGRAM BAC 6988 B C BAC- 11490A 20000Baltimore Almon Compaq. NI Rights Reserved. OPERATING INSTRUCTIONS Follow the installation drawings and wiring diagram (see chart below) to ensure the proper operation of the vibration switch. Direct any questions to your local BAC Representative. NOTE Moisture inside the switch can lead to switch failure. Care must be taken when replacing the cover on the vibration switch to ensure that the proper watertight seal is obtained. CAUTION Before performing any maintenance, adjustment or inspection of the switch, make certain that all power has been disconnected and locked in the off position. WIRING DIAGRAM CHART BAC- 17491A =Shut down with local reset BAC- 17492A =Shut down & alarm, with remote or local reset & time delay on start (110 Vac) BAC- 17493A =Shut down & alarm, with remote or local reset & time delay on start (220 Vac) GUARD (REMOVED SWITCH LOCATION LOW PROFILE SERIES V MOUNTING BRACKET VIBRATION CUTOUT SWITCH B.A.C. ORDER NO: U070805601 DATE: 03/14/07 SWITCH LOCATION SERIES V 0 VIBRATION CUTOUT Q SWITCH BALTIMORE AIRCOIL COMPANY MECHANICAL VCOS LOCATION CENTRIFUGAL FAN UNITS BRAVING NUMBER: BAC- 11490A BAC-17491A 20000 BalUmors Aircop Company. AN RIO* Reearet I NOTES; 1. LOCAL PUSH BUTTON RESET. 2. TO MAINTAIN HAZARDOUS DUTY RATINGS, THE FACTORY INSTALLED WATER TIGHT CONDUIT /CABLE CONNECTION FITTINGS MUST BE REMOVED AND THE FOUR CONDUCTOR CABLE MUST BE ROUTED INSIDE OF A SUITABLE EXPLOSION PROOF CONDUIT. NOTE: THE CONNECTORS CAN EASILY BE REMOVED WITHOUT HAVING TO UN -WIRE THE CONDUCTORS FROM INSIDE THE CUTOUT SWITCH. 3. THE MECHANICAL VIBRATION CUTOUT SNITCH COMES WITH TWO WATER TIGHT CONDUIT /CABLE CONNECTORS. ONE CONNECTOR IS USED TO PROVIDE A WATER TK;HT CONNECTION TO THE VIBRATION CUTOUT SWITCH AND THE OTHER IS PROVIDED FOR THE ELECTRICIAN TO CONNECT THE WIRE CABLE TO A JUNCTION BOX LOCATED IN THE VICINITY OF THE VIBRATION CUTOUT SWITCH. 4. THE SWITCH IN THE NORMALLY CLOSED CIRCUIT (BLACK WIRE) WILL OPEN WHEN THE DEVICE EXPERIENCES VIBRATION LEVELS ABOVE THE SETPOINT VALVE. IF REVERSE CONTROL LOGIC IS DESIRED, CUT OFF THE BUTT END CONNECTOR ON THE WHITE WIRE AND INSTALL A WIRE NUT OR BUTT CONNECTOR ON THE NORMALLY CLOSED WIRE (BLACK). 5. THIS MECHANICAL VIBRATION CUTOUT SWITCH COMES WITH ONE SINGLE POLE DOUBLE THROW SWATCH. THE SWITCH CONTACTS ARE 'DRY CONTACTS' WHICH CAN BE SUCCESSFULLY USED DIRECTLY IN THE FAN STARTER CONTROL (TYPICALLY A/C VOLTAGE) CIRCUIT OR DIRECTLY IN A BUILDING MANAGEMENT SYSTEM (TYPICALLY D/C VOLTAGE). CONTACT RATINGS: 3 AMPSO 125 OR 480 VAC, 1/2 AMPO 125 VDC, 1/4 AMPO 250 VDC. B. CAUTION: MOISTURE INSIDE THE SWITCH CAN LEAD TO SWITCH FAILURE. CARE MUST BE TAKEN WHEN REPLACING THE COVER ON THE VIBRATION SWITCH TO ENSURE THAT THE PROPER WATERTIGHT SEAL IS OBTAINED. ADJUSTMENTS OF BAC MECHANICAL VIBRATION CUTOUT SWITCH BAC RECOMMENDS THAT EACH VIBRATION CUTOFF SWITCH BE FIELD ADJUSTED AT START -UP TO OPTIMIZE THE TRIP POINT RELATIVE TO THE FINAL MOUNTING POSITION AND VIBRATIONAL CHARACTERISTICS OF THE INSTALLED EQUIPMENT. NOTE: INSTALLATION AND ADJUSTMENT MUST BE PERFORMED BY A QUALIFIED, COMPETENT TECHNICIAN 1. FOR SAFETY SAKE, TURN OFF, THEN LOCK & TAG -OUT THE ELECTRICAL SUPPLY TO THE FAN MOTOR(S). 2. TURN ADJUSTMENT SCREW COUNTERCLOCKWISE (CCW) 1/8 TURN AT A TIME UNTIL YOU HEAR THE CONTROL TRIP. 3. ONCE TRIPPED, ROTATE ADJUSTMENT SCREW 1/4 TURN CLOCKWISE (CW) AND THEN PUSH IN MANUAL RESET BUTTON. 4. START UP FAN(S) TO DETERMINE IF THE START -UP WILL CAUSE THE CUT -OUT SNITCH TO TRIP. 5. IF THE VIBRATION CUTOUT SWITCH DOES NOT TRIP, THEN START AND STOP THE FAN TWO MORE TIMES AND IF THE CUTOUT SWITCH STILL DOES NOT TRIP, THEN CAUBRATION IS COMPLETE. IF THE VIBRATION CUTOUT SWITCH DID TRIP, THEN TURN OFF, THEN LOCK & TAG -OUT THE ELECTRICAL SUPPLY TO THE FAN MOTOR(S). ADJUST THE SET POINT SCREW AN ADDITIONAL 1/4 TURN CW AND THEN DEPRESS THE RESET BUTTON. RE -START THE FANS) TO DETERMINE IF THE START -UP WILL CAUSE THE SWITCH TO TRIP. REPEAT THIS ADJUSTMENT PROCESS UNTIL THE CONTROL DOES NOT TRIP. ONCE NE FINAL ADJUSTMENT HAS BEEN MADE, START AND STOP THE FAN TWO MORE TIMES AND IF THE CUTOUT SWITCH STILL DOES NOT TRIP, THEN CAUBRATION IS COMPLETE. B.A.C. ORDER N0: U070805801 DATE: 03/14/07 MECHANICAL VIBRATION CUT -OUT SWITCH (ONE— SINGLE POLE DOUBLE THROW SWITCH) SETPOINT ADJUSTMENT 7' FLEXIBLE JACKET CUSTOMER WIRES (FOR HAZARDOUS RATINGS SEE NOTE 2) WATER PROOF CONDUIT CONN (SEE NOTE 3) LOCAL RESET (SEE NOTE 1) WATERTIGHT SEAL (SEE NOTE 6) MOUNTING PLATE WIRING DIAGRAM (ONE — SINGLE POLE DOUBLE THROW SWITCH — SEE NOTE 5) TO CUSTOMER FAN CIRCUIT OR BUILDING MANAGEMENT SYSTEM (SEE NOTE 5) (SEE NOTE 4) a (WHITE) (RED) (BLACK) (GREEN) 9 N.O. COMMON Eti N.C. BAC PART# 311788 CASE GROUND BEFORE PERFORMING ANY MAINTENANCE, ADJUSTMENT OR INSPECTION OF THE SWITCH, MAKE CERTAIN THAT AU. POWER HAS BEEN DISCONNECTED AND LOCKED IN THE OFF POSITION. SHUT OFF WITH LOCAL RESET BALTIMORE AIRCOIL COMPANY MECHANICAL VCOS WIRING DIAGRAM ORA tONO NtM BAC- 17491A B ACTIVITY NUMBER: M07 -059 DATE: 03 -23 -07 PROJECT NAME: TUKWILA COMMERCE CENTER SITE ADDRESS: 631 STRANDER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: � AIG 3, Zi.D1 Building Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: DUE DATE: 04-24-07 Approved n Approved with Conditionslil Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 ►� PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire revention Structural Incomplete ❑ Planning Division ❑ Permit Coordinator DUE DATE: 03-27-07 Not Applicable C No further Review Required DATE: DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PROSTMI072NG Licensee Name PRO STAFF MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601038859 Ind. Ins. Account Id 52073600 Business Type CORPORATION Address 1 PO BOX 33370 Address 2 City SEATTLE County KING State WA Zip 98133 Phone 2063610071 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/7/1993 Expiration Date 6/30/2008 Suspend Date Separation Date Parent Company Previous License PROSTHA 136NJ Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ALMO, LEONARD L PRESIDENT 08/07/1993 Bond Amount ALMO, PENNY VICE PRESIDENT 08/07/1993 103645389 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #7 TRAVELERS CAS & SURETY CO 103645389 08/07/2001 Until Cancelled $12,000.00 07/30/2001 Swv Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= PROSTMI072NG 04/10/2007 • ,— 15.403 SF. 5' SETBACK GM 60' NIDE SETBACK BLDG A 10.564 SF BLOC E SF: BLDG B 9.826 SF. 11,701 SF. 312.25' 10' UTILITY ESMT SL tilt; 3.2'6 0.8' 0.6' AIMS: IF I I F 1 R, t. M - = la Bnite Roc* It Purr ROOM 2.7' 1.2' 588111' 127. '0' ROCKERY Gil TRACT 2 S TR�4 NDER - BL VD 48 ?.7 397.81' n 10 .. N1 DE ry ESAI 58875'33'£ 46Z69' .• •a• Parcel Number: 023300020 BAC (Baltimore Air Cod) FOUND 1' IRON PIPE w/ CAP FAR PLUG LS/11568 N40- 23 -33E 0.42' 7/31/00 SCALE: l" =50' SITE PLAN EOUIPMIE?T NOTES: I) en Certified Thermal Performance. 2) ISO 9000/9001 Certified Manufacturing Plant 3) G235 Galvanized Steel Coostroction 4) 7% HP Inserter Duty Premium Efficient Fan Motor. 5) Float Water Level Control Package. 6) Electric Emersion Heaters and Controls. 7) Mechanical Vdiration Cutout Switch. 8) Seismic Zone.' IBC 1997 Unit Anchorage. 9) Existing Model being replaced: B.A.0 B S'NT - -70B 5' SETBACK REPLACE EXISTING COOLING TOWER WITH NEW. "LIKE- FOR - LIKE" REPLACEMENT / TIIE COOLING TOWER IS LOCATED ON THE GROUND WITHIN IT'S t COOLING TOWER ENCLOSURE. COOLING TOWER ENCLOSURE SCALE: % " =1' -0" COOLING TOWER REPLACEMENT EQUIPMENT SCHEDULE OPERATEt \G I TAG I MAKE I MODEL# Certified Capacity I Fan Motor ELECTRICAL WEIGHT LBS V 0-65.1 j 210 UJSGPM 73 HP i 460.3'60 2, E 588191' : 5'E 306.53' • 0.7' N. 1.6' Fig FOUND 1' IRON PIPE W/ ORANGE PLUG N74- 31 -47E 0:33' 7/31/00 • • • • REPLACE EXISTING COOLIN TOWER WITH NEW. "LIKE- FOR - LIKE" REPLACEMENT THE COOLING TOWER IS LOCATED ON TILE GROUND WITHIN IT'S COOLING TOWER ENCLOSURE. - — - • • 1 • • • • N N ASPHALT PATH 1 FOUND 3/4' /ROM PIPE w/ PLUG : S72- 28 -02E 0.18'• 8/17/00 1 FOUND 3/4' IRON PIPE w/ PLUG N60- 52 -17E 0.11 8/17/00 • • • COOLING TOWER REPLACEMENT SCOPE OF WORK: ♦ Supply & install one new BAC cooling tower Model II VTO -65 -J in the same location. This is the BAC filctoiy recommended replacement /equivalent for the existing tower. ♦ Reconnect to the existing water loop piping, domestic water supply piping, and drains. ♦ Refill, start-up and test operation of tower. ♦ Includes crane, rigging, and equipment transportation. ♦ Removal and disposal provisions. ♦ Mechanical permit and drawing. g G•'6 Pt City of Tukwi!a BUILDING DIVISION I- VICINITY MAP Plan review approval Is subject to errors and om Approval cons�x� documents does not authorize violation of en./ ccorwj • 0 or a approved Fw,:; ordinance. Rem Zorn Is admaviedgid: i r "lirs S C� itad3t,C:oc .V.7.7 • :. _ r::T �.� ,...c :1 c7 I►G. C: Will uire a new Wan �.�,,/ m4 l; nlbm;t�l and may Include addftlonal plan review fees. PacHk Gull Business Park Tara I U �� 1lJkWlla DIVISION R EVIEWED Ol= R COD COMPLIANCE MAR 2 8 zoo/ tY Of Tuk BUILDING 9IVISIO V Phase IV Phase Y • OFFICE Blvd. 4 COOLING TOWER LOCATION REVISIONS SHEET NUMBER JOB #1191 a C 4 M • c s • o► c 'C u) i � g 0. N C E O N 2 m 0.121 E 0 H z U � 0.4 454 a� sae �,A3 WO a 0 ;11 E e i a 6 o� 0 c� DRAWN PG DATE 3Ai/o7 CONTENTS , nJ '�• - + lttit M -1 Am*-Gs1 1