HomeMy WebLinkAboutPermit M07-059 - TUKWILA COMMERCE CENTERTUKWILA COMMERCE
CENTER
631 STRANDER BL
M07 -059
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
0223300020
631 STRANDER BL TUKW
TUKWILA COMMERCE CENTER
631 STRANDER BL , TUKWILA WA
Owner:
Name: CALWEST INDUSTRIAL PROP
Address: C/0 DELOITTE & TOUCHE LLP , 2235 FARADAY AVE #0
Contact Person:
Name: PETER CRELLEY
Address: PO BOX 33370 , SEATTLE WA
Contractor:
Name: PRO STAFF MECHANICAL INC
Address: PO BOX 33370 , SEATTLE WA
Contractor License No: PROSTMI072NG
DESCRIPTION OF WORK:
REPLACE (1) EXISTING COOLING TOWER LIKE- FOR -LIKE
Value of Mechanical: $18,000.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
doc: IMC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
MECHANICAL PERMIT
EOUIPMENT TYPE AND OUANTITY
0
0
0
0
0
0
0
0
1
0
0
0
0
0
* *continued on next page **
M07 -059
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 361 -0071
Phone: 206 -361 -0071
Expiration Date: 06/30/2008
Steven M. Mullet, Mayor
Steve Lancaster, Director
M07 -059
04/10/2007
10/07 /2007
Fees Collected: $361.78
International Mechanical Code Edition: 2003
Boiler Compressor:
0 - 3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15-30 HP/1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP/1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment 0
Printed: 04 -10 -2007
Permit Center Authorized Signatur
I hereby certify that I have read an
governing this work will be complie • , "' ther specified herein or not.
doc: IMC -10/06
Print Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 -431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
.11
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: M07 -059
Issue Date: 04/10/2007
Permit Expires On: 10/07/2007
Date: UI 1 10
permit and know the same to be true and correct. All provisions of law and ordinances
The granting of this permit doe not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perfo � of work. I am authorized to sign and obtain this mechanical permit.
9 / �
Si tore: Date: /l oft) ?
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspendec
or abandoned for a period of 180 days from the last inspection.
M07 -059 Printed: 04 -10 -2007
Parcel No.: 0223300020
Address:
Suite No:
Tenant:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
631 STRANDER BL TUKW
TUKWILA COMMERCE CENTER
PERMIT CONDITIONS
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
5: Manufacturers installation instructions shall be available on the job site at the time of inspection.
M07 -059
ISSUED
03/23/2007
04/10/2007
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
7: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances
shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms,
bathrooms, toilet rooms, storage closets, surgical rooms.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Cond -10/06 M07 -059 Printed: 04 -10 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
doc: Cond - 10/06
Date: 711vp
M07 -059 Printed: 04 -10 -2007
CITY OF TUKIlkA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http.11www.ci.tukwila.wa.us
Site Address: 6 31 STRAN DER, R L VD.
Tenant Name: TIA kW IL—A— CU tKME(Lt..E C'ENTEE2 New Tenant: ❑ Yes '� � No
Property Owners Name: 1
Mailing Address: 6'31 S?1ZANDER SLV D. t ,
do a co ttaet vhen yoas
permit is ready •to be
Name: PETE C 4 E Lt `1 Day Telephone: 206 - 31,1.-007)
Mailing Address: P. O. gUx 33370 SPF[TLE 1"► A '33
City State zip
E-Mail Address: PErE12@ P a- STAFFMEC NA-All CA L LUYY1 Fax Number: 206 — 3 61 —O 7-4—
aniust<;berct
.. ...............................
Company Name:
Mailing Address:
Company Name:
Mailing Address:
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print"
INFORMA
...............................
..............................
i g 4) for P hi
Contact Person:
E-Mail Addres Fax Number:
Co .r Registration Number: Expiration Date:
StAt•rc Ca 7�k w llI
City
Contact Person:
King Co Assessor's Tax No.: O233O OD 2-0
Suite Number: N/A Floor: ON 6R0w O
City
E-Mail Address: Fax Number:
Q: Wpplicati . - ....- Applications On t;nev -2006 - PamitApplication.doc
wA 99,106
state
State
Zip
Company Name:
Mailing Address:
State Zip
hone:
Page
:UnitType:
Unit Type:
;Qty
. Unit:. �'Pe
C�ly :
'B+uIerLCompFessar..
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0-3 111 BTU
Furnace>100K BTU
Evaporator Cooler
I
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30-50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refig/Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
MECHANICAL CONTRACTOR INFORMATION
Company Name: Peo - STA FP M scN- PrN1 CAL IN L.,
Mailing Address: eo. 3cpC 33370 s, - rYLE i j ciPrK3
City
State zip
Contact Person: ?£TE12 CSZE Y Day Telephone: Z0t —3(,1 —0071
E-Mail Address: PETER. e PRO STPIFFMFCH AIU IC 141-• COI Fax Number: 206 --361-
Contractor Registration Number: PQ.0 STM I U 71 N 6 Expiration Date: 6
Valuation of Mechanical work (contractor's bid price): $ 19,000
Scope of Work (please provide detailed information): /z EPL41-C-E (1) £X / 5 T /NC? COU Ll /U G
77, Ems, L /kE - RJR-- Li
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... ❑ Replacement / K
Fuel Type: Electric Gas ....0 Other:
Indicate type of mechanical work being installed and the quantity below:
Q: ardie 1 ' ns- AAPUcanons On t:au -woe - Permitnyplicanoa.doe
Revised: 9-2006
bh
Page 4 of 6
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING O ` ► , OR ."I RIZED AGENT:
Signature: % Date: 3113/ 07
Print Nam . l - L 040 Day Telephone: ZO ( - 36 I - 007 1
Mailing Address: F.6. T1/4) •370 6EA
City
Date Application Accepted: t ole__
Q Wppliation.Tmn.Applicatione On line 3 -2006 - Permit Apptinson.doc
Revised 9-2006
bh
wA `' 133
Zip
Date Application Expires:
Staff Initials:
(....1
Page 6 of 6
i
Receipt No.: R07 -00426
Payee: PRO -STAFF MECHANICAL, INC.
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
PLAN CHECK - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 0223300020 Permit Number: M07 -059
Address: 631 STRANDER BL TUKW Status: PENDING
Suite No: Applied Date: 03/23/2007
Applicant: TUKWILA COMMERCE CENTER Issue Date:
Initials: JEM Payment Date: 03/23/2007 01:47 PM
User ID: 1165 Balance: $0.00
TRANSACTION LIST:
Type Method Description Amount
Payment Check 10180 361.78
Account Code Current Pmts
000/322.100 295.42
000/345.830 66.36
Total: $361.78
Payment Amount: $361.78
m
'j3/23
7 } T' N
doc: Receiot -06 Printed: 03 -23 -2007
Proms
/ ? /1 / ./f7O rirni/e-C
Type of Inspection:
/=i.t/ 7 /
Address:
.3 / ...5 1 4 4dr-,
.6/_—
Date Called:
Special Instructions:
/ /
/
Date Wanted:
7 --
// d 7
6.m.
Parr
Requester:
Phone No:
7 5 - 5 3
/9 1e 7 - -0SS
INSPECTION NO. PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 . 6)431 -3670
I spector.
pproved per applicable codes. Corrections required prior to approval.
COMMENTS:
? /&f 4 m v,y
term / 4 ,ito
INSPECTION RECORD
Retain a copy with permit
1 4
•. EINSPECTION FEE REQ ED. Pri to inspection, fee must be
al t 6300 Southcenter Blvd., Su e 100. ll the schedule reinspection.
(Receipt No.: 'Date:
Date:
PROJECT
w
ANDOVER PARK TRACT 2 ..
CONTRACTOR
Pro Staff Mechanical
LOCATION
Tukwila, WA , ._
r ? I$:ilN TO
Ij REp s
,,.c
3290 146th Pl. S.E. / Bellevue, Wash 98007
(425) 562 -1150
(425) 562 -5123 fax
1. Galvanized Steel Construction
2. PVC Drift Eliminators
3. Seismic Zone 4 UBC Unit Anchorage
4. Electric Emersion Heaters and Controls
5. Mechanical Float Valve
6. Mechanical Vibration Cutout Switch
7. 7.5HP Inverter Duty Fan Motor
SUBMITTAL
EQUIPMENT
MANUFACTURER
OPEN COOLING TOWER
BALTIMORE AIR COIL
P:
FILE Copy \
P t No.
Representative:
Included with the Cooling Tower are the following options:
Matthew Adkins /AD
Date of Submittal: 3/14 /2007
REVIEWED FOR
CODE COMPLIANCE
A nPo FD
MR a 6 x001
OT 1�ifidil�
WILD NG DIVISION
CRY OF
MAR 2 3 2007
PERMIT CENTER
Submittal Information
Equipment Summary
BAC Terms and Conditions of Sate
• CTi Certified Thermal Performance
Mechanical Specifications
• Steel Panels and Structural Members are Constructed of
Galvan Steel
Sound Data
• Polyvinyl Chloride (PVC) Drift Eliminators
• Non - Corroding PVC Film Fill Material with a Flame Spread
Submittal Drawings/Diagrams
Rating of 5
Unit Print - Right Hand (BAC -9105 A)
• Side Outlet Pump Suction Connection
Steel Support (BAC- 13238A)
• Seismic Zone 4 UBC 1997 Unit Anchorage
Heater Location (BAC -9144 A)
• Electric Immersion Heaters Sized to Maintain +40 °F water
Heater Wiring (BAC -6988 B)
at a OF Ambient with Electrical Requirements Matching
Vibration Cutout Switch Location (BAC- 11490A)
Fan Motor(s)'
Vibration Cutout Switch Wiring (BAC- 17491A)
• Electric Immersion Heater Controls
• Mechanical Float Valve Assembly
• Mechanical Vibration Cutout Switch
See Mechanical Specifications & Drawings for more
detail.
.Miffed
Your P. O. Number.
BALTIMORE AIRCOIL COMPANY
Submittal Data Form
Sold To: Washington Air Reps
3290 146th Place S. E.
Suite A
Bellevue, Washington 98007
Certified Capacity:
Fan Motor(s):
CC: Washington Air Reps Inc.
Project:
Engineer
Representative:
One (1) Model VT8 -651J Cooling Tower Unit
M Information is Per Unit
Washington Air Reps Inc.
March 14, 2007
Our B.A.C. Number. U070805601
Andover Park Tract 2 — Tukwila,
Washington
210 USGPM of Water from 90 °F to 80 °F at 70 °F entering air wet bulb and 5.07 PSIG of total
(static lift + spray) pump head from the unit base.
One (1) 7.5 HP fan motor totally- endosed, fan - cooled (TEFC), inverter duty, suitable for 200
volt, 3 phase, 60 hertz electrical service. Fan drives are based on 0 inches ESP.
NOTE: Inverter Duty fan motors, furnished In accordance with NEMA Standard Mg.1 — Part 31, are required for applications using
variable frequency drives for fan motor control.
Corporate Headquarters: P. O. Box 7322, Baltimore, MD 21227 — Tele: (410) 799-6200 / Fax: (410) 799-6416
Thank you for your order. Further processing of your order is contingent upon receipt of approved submittals. Early
release is necessary to meet your project requirements.
Current Rigging and Installation Instructions, as well as Operating and Maintenance Instructions, are available at our
website: www.batiimoreaircoil.com.
Project:
Customer:
Purchase Order No.:
Engineer:
Model:
B.A.C. Serial No.:
Fan Motor:
CTI Certification:
Baltimore Aircoil Company
Mechanical Specifications
03/14/2007
Andover Park Tract 2
Washington Air Reps
One (1) Model VT0 -65/J Cooling Tower Unit
U070805601
All Information is Per Unit
S
Unit Type:
Factory- assembled, counterfiow, forced draft design cooling tower.
Quality Assurance:
Each unit is manufactured under closely- controlled conditions using standardized parts to ensure
each unit is built precisely to the same high - quality design and construction standards. The
design, manufacture, and business processes of Baltimore Aircoil Company are ISO 9001:2000
certified.
Unit Efficiency:
The cooling tower(s) complies with the energy efficiency requirements established by ASHRAE
Standard 90.1 -2001.
One (1) 7.5 HP fan motor: totally - enclosed, fan - cooled (TEFC), inverter duty, suitable for 200
volt, 3 phase, 60 hertz electrical service. Inverter Duty fan motors, furnished in accordance with
NEMA Standard Mg.1 — Part 31, are required for applications using variable frequency drives for
fan motor control.
The thermal performance is certified by the Cooling Technology Institute in accordance with CTI
Certification Standard STD -201.
Materials of Construction:
All structural steel components are constructed from G -235 (Z700 metric) hot -dip galvanized
steel. The edges of the hot -dip galvanized steel components are given a protective coat of
zinc -rich compound. Circular access doors provided for interior inspection, deaning, and
adjustments are constructed of G -235 (Z700 metric) hot -dip galvanized steel and are held in
place with phenolic knob screws. The heat transfer casing section(s) is (are) removable from the
pan/fan section to facilitate rigging.
Corporate Headquarters: P. O. Box 7322, Baltimore, MD 21227 — Tele: (410) 799 -6200 / Fax: (410) 799 -6416
The centrifugal fans and motors are located in the dry entering airstream beneath the sloping
side of the pan. Fan discharge cowls, constructed of G-235 (Z700 metric) hot-dip galvanized
steel, are provided on each fan. They extend within the pan to protect the fans from falling water.
G -235 (Z700 metric) hot -dip galvanized steel fan guard screens are provided.
A hollow steel fan shaft, protected with two part epoxy, with bearing journals at each end is
utilized. Solid polished steel journals are coated with a rust preventative. Self- aligning,
heavy -duty, grease - packed ball bearings with eccentric locking collars are furnished at each end
of the shaft.
V belt sheaves, selected for 150% motor nameplate horsepower, are mounted and aligned at the
factory. The fan(s), fan shaft(s), bearings, mechanical equipment support and fan motors are
warranted against defects in materials and workmanship for five (5) years from date of shipment.
Drift Eliminators:
Wet Deck:
Water Outlet:
Basin Heaters:
Drift eliminators are constructed of polyvinyl chloride (PVC), and are removable in easily handled
sections. They impart three distinct changes in air direction to effectively strip entrained moisture
from the leaving airstream with minimum air resistance.
Serpentine polyvinyl chloride (PVC) BACount® Wet Deck Surface is impervious to rot, decay,
fungus or biological attack and has a flame spread rating of 5 per ASTM Standard E84 - 77a. Wet
deck is suitable for a maximum entering water temperature of 130 °F(54 °C).
The process water is distributed over the wet deck surface via a spray header with schedule 40
PVC removable branches with large orifice plastic spray nozzles which are held in place with
snap -in rubber grommets.
A pipe stub connection(s) of a metal compatible with the cold water basin material and
appropriately sized for design flow is provided. A large area lift out strainer screen with
anti - vortexing hood matching the cold water basin material of construction is included to prevent
air entrainment.
Anchorage:
When supported as recommended, the unit has anchorage to resist wind loads up to 30 psf
(146.6 kg/m "2) acting on the full vertical projected area with 16 psf (78.1 kg/m "2) acting
simultaneously on the full horizontal projected area or seismic forces of 161% of the operating
weight acting in the horizontal direction, and 24% of the operating weight acting in the vertical
direction applied at the center of gravity. Loads are appropriate for Seismic Zone 4 assuming an
Importance factor of 1.0, and soil profile SD, and rigid mounting to the supporting structure per
the 1997 Uniform Building Code.
A minimum number of high - watt- density electric immersion heater elements, sized to maintain
+40 °F (+4 °C) basin water at 0 °F ( -18 °C) ambient with a 10 mph (16 km/h) wind speed, is
provided. Electrical requirements match fan motor. Wring is not included.
Basin Heater Controls:
An electric immersion heater control package, including thermostat(s) and low water cutout
switch(es) or probe(s), is provided. Disconnect switch, contactor, and wiring are not included.
Corporate Headquarters: P. 0. Box 7322, Baltimore, MD 21227 — Tele: (410) 799 -6200 / Fax: (410) 799 -6416
Basin Water Level Control:
Bronze make -up valve with unsinkable polystyrene filled plastic float arranged for easy
adjustment. The make -up valve is suitable for water supply pressures between 15 psig (103
kPa) and 50 psig (345 kPa).
Vibration Cutout Switch:
Fan system is provided with an appropriate number of vibration cutout switches to limit collateral
damage to the unit in the event of a catastrophic fan failure. The vibration switch(es) is
mechanically tripped with a frequency range of 0 to 3,600 RPM and trip point of 0.2 to 2.0 g's. No
input power is required. Switch rating is 10 amperes at a maximum 480 VAC, and 1/4 ampere at
250 Vdc.
Corporate Headquarters: P. O. Box 7322, Baltimore, MD 21227 — Tele: (410) 799 -6200 / Fax (410) 799 -6416
Sound Power (dB)
Octave
Band
Center Frequency
(Hertz)
Lw
5ft
63
r N CO C U, w P O
(OW (0 (0(82
125
A-wgtd
250
55
500
U,
1000
2000
4000
8000
End Lp
Sound Pressure (dB)
Octave
Distance
Band
5ft
50ft
r N CO C U, w P O
(OW (0 (0(82
881` 7$474;
A-wgtd
69
55
Back Lp
Sound Pressure (dB)
Octave
Distance
Band
5ft
50ft
r NM V' It) 1OP
tMO tn'iO433
iX e�i 1�i 1�r 1�e 1gi a �
A-wgtd
70
54
Top Lp
Sound Pressure (dB)
Octave
Distance
Band
5 ft
50 ft
.- C\ CI I11 40fsM
001 ° n CD ID (0
iX e�i 1�i 1�r 1�e 1gi a �
A-wgtd
74
57
End Lp
Sound Pressure (dB)
Octave
Distance
Band
5ft
50ft
rN of u) CO P CO
A-wgtd
69
55
Air inlet Lp
Sound Pressure (dB)
Octave
Distance
Band
5 ft
50 ft
r NMV' 10 (OF(0
A-wgtd
75
58
Baltimore Aircoil Company
Sound Rating Program, 2/8/2007 Release
Series V VTONTI
Model : VTO -65-J
Total Fan Motor Horse Power : 7.5 HP
Fan Speed & Total Fan Power Used : Full Speed, 7.5 BHP
Accessories : None
Octave band and A- weighted'sound pressure levels (Lp) are expressed in decibels
(dB) reference 0.0002 microbar. Sound power levels (Lw) are expressed in
decibels (dB) reference one plcowatt. Octave band 1 has a center frequency of 63
Hertz.
COPYRIGHT 1991, BALTIMORE AIRCOIL COMPANY
BAC -9105 A
15.
20 3/8"
< . MAKE f
e •u�; OW
I > M
u r I 1 j 4 WATER OUT
M 2 DRAIN
e " a 2 1/4" —
CO CO 013
4 1/8" --
"� 17 1/4"
co N co
cV
3' -4 3/4" r—
i
x--30"
3' -11 1/2" --
NOTES;
1. ALL DIMENSIONS ARE IN FEET AND INCHES. WEIGHTS ARE IN POUNDS.
2. UNLESS OTHERWISE INDICATED ALL CONNECTIONS 3 INCHES AND SMALLER ARE MPT
AND CONNECTIONS 4 INCHES AND LARGER ARE BEVELLED FOR WELDING AND GROOVED
FOR VICTAULIC CONNECTION.
3. FOR SUPPORT REQUIREMENTS, REFER TO THE SUGGESTED STEEL SUPPORT DRAWING.
4. PRE — FABRICATION OF FINAL CONNECTING PIPEWORK IS NOT RECOMMENDED.
5. DO NOT SUPPORT PIPING FROM COOLING TOWER. ALL NECESSARY PIPE SUPPORTS ARE
TO BE SUPPLIED BY OTHERS.
MODEL
NO.
VTO -65/J
VTO -75 —K
VTO -78 —K
VTO -88 —L
APPROX.
SHPG. WEIGHT
2000
2010
2130
2190
APPROX.
OPER. WEIGHT
2580
2590
2710
2770
B.A.C.
ORDER NO: U070805601
DATE: 03/14/07
y
HEAV. SECT.
(PAN)
1070
1080
1080
1140
A
8' -1 7/8"
8' -1 7/8"
9' -7 7/8"
9' -7 7/8"
H
9' -0 1/8"
9' -0 1/8"
10' -6 1/5"
10' -6 1/8"
BALTIMORE AIRCOIL
COMPANY
COOLING TOWER
DRAWING NUMBER:
BAC -9105 A
C
MODEL
NO.
DIMENSION
*
(SEE NOTE 3)
A
B
VTO -12 -E
THRU
VTO-28-H
45
3/8
24 5/8
3/32
VTO -32 -H
THRU
VTO -57 -K
45
3/8
59 1/2"
3/16
► � -J
THRU
VTO -88 -L
45
3/8
68"
5/16
VTO -102 -L
THRU
VTO -116 -M
45
3/8
104 3/4"
3/8
VTO -132 -L
THRU
VTO -176 -0
54
1/4
104"
3/8
BAC- 13238A
20050 Minors NrcoA Compaq. M Rights heaved. 1
NOTES;
1. THE RECOMMENDED SUPPORT ARRANGEMENT FOR VTO UNITS CONSISTS OF
TWO PARALLEL I -BEAMS EXTENDING THE FULL LENGTH OF THE UNIT. SUPPORTS
AND ANCHOR BOLTS ARE TO BE DESIGNED AND FURNISHED BY OTHERS.
2. ALL SUPPORTING BEAMS ARE TO BE FLUSH AND LEVEL AT TOP AND MUST BE
ORIENTED RELATIVE TO GAGE LINE AS SHOWN.
3. RECOMMENDED DESIGN LOADS FOR EACH BEAM SHOULD BE 657. OF THE TOTAL
UNIT OPERATING WEIGHT APPLIED AS A UNIFORM LOAD TO EACH BEAM. BEAMS
SHOULD BE DESIGNED IN ACCORDANCE WITH STANDARD STRUCTURAL PRACTICE.
ThE MAXIMUM ALLOWABLE DEFLECTION OF BEAMS UNDER THE UNIT SHALL BE
(REFER TO CHART) OF AN INCH.
4. ALL MOUNTING HOLES ARE 7/8 INCH DIA. AT THE LOCATIONS SHOWN.
5. IF VIBRATION ISOLATORS ARE USED, A RAIL OR CHANNEL MUST BE PROVIDED
BETWEEN THE UNIT AND THE ISOLATORS TO PROVIDE CONTINUOUS UNIT SUPPORT.
ADDITIONALLY THE SUPPORT BEAMS MUST BE DESIGNED TO ACCOMMODATE THE
OVERALL LENGTH AND MOUNTING HOLE LOCATION OF THE ISOLATORS WHICH MAY
DIFFER FROM THOSE OF THE UNIT. REFER TO VIBRATION ISOLATOR DRAWINGS FOR
THESE DATA.
B.A.C.
ORDER NO: U070805601
DATE: 03/14/07
AIR INLET SIDE
B
BALTIMORE AIRCOIL
COMPANY
OUTLINE OF UNIT
v
(4) 7/8 MOUNTING HOLES
SUGGESTED STEEL SUPPORT: VTO
SEISMIC ZONE 4 UBC 97/30 PSF WIND
DRAWING NUMBER:
BAC- 13238A
MODEL NO.
NO. OF
HEATERS
TOTAL HEATER (kw)
0'
—20'
VTO -12 —E THRU VTO -28 —H
1
2
2
VTO -32 —H THRU VTO -57 —J
1
2
2
• VTO -65 —J THRU VTO -88 —L
1
2
3
VTO -102 —L THRU VTO -116 —M
1
3
5
COPYRIGHT 1991, BALTIMORE AIRCOIL COMPANY
BAC -9144 A
NOTES;
1. OMIT THE 1" FPT CUTOUT LOCATION
WHEN AN ELECTRIC WATER LEVEL CONTROL
PACKAGE IS USED. THE LOW WATER
CUTOUT WILL BE FURNISHED AS PART OF
THE ELECTRIC WATER LEVEL CONTROL
PACKAGE.
2. HEATERS: SUITABLE 200 VOLTS, 3 PHASE, 60 HERTZ
0'F AMBIENT TEMPERATURE
END OPPOSITE PIPING CONNECTION
RIGHT HAND UNIT SHOWN
LEFT HAND UNIT MIRROR IMAGE
B.A.C.
ORDER NO: U070805601
DATE: 03/14/07
THERMOSTAT
BALTIMORE AIRCOIL
COMPANY
1" FPT CUTOUT
(SEE NOTE 1)
1/2" FPT THERMO. PROBE
ELECTRIC HEATER PACKAGE
DRAWING NUMBER:
BAC -9144 A
A
COPYRIGHT 1985, BALTIMORE AIRCOIL COMPANY
BAC -6988 B
DISC0NNFCT SWITCH FUSE MAGNETIC CONTACTS
(BY OTHERS) (BY OTHERS) (BY OTHERS)
■ y (WIRE MULTIPLE HEATERS
L1 - 1 b- -0 - o-' 1 1 - - - -\ IN PARALLEL)
I C1
U -o i `4:)- -0 = o-
�J
L3 -o `o- - {1- 0
N
r
HEATER CONTROL
POWER SUPPLY 1
H - - - - -
- �] - , -fl_a -
mdla amain B1SE
MICH CONTACT -N.Q. (BY OTHERS)
(BY OTHERS) SPRAY WATER PUMP
(BY OTHERS
SEE NOTE 1)
B.A.C.
ORDER NO: U070805601
DATE: 03/14/07
LOW WATER
PENN F -63
(BY BAC)
II
IIC
ci
— —
THERMOSTAT 1010
PENN A19 -ANC MAGNFTIC CONTACTOR
(BY BAC -SEE NOTE 2) (BY OTHERS - SEE NOTE 4)
NOTES:
1. INTERLOCK IMMERSION HEATERS WITH CIRCULATING PUMP
TO DE- ENERGIZE HEATERS WHEN PUMP IS RUNNING.
2. CONTROL THERMOSTAT IS TO BE SET FOR 40' F. DO NOT
SET THERMOSTAT LOWER THAN 40' F.
3. BROKEN UNES INDICATE COMPONENTS AND WIRING TO BE
SUPPUED BY OTHERS.
4. CONTACTOR, FUSE PROTECTION AND POWER SUPPLY WIRING
ARE TO BE SIZED TO MATCH HEATER REQUIREMENTS. WIRING
MUST COMPLY TO APPUCABLE CODES AND ORDINANCES.
BALTIMORE AIRCOIL
COMPANY
ELECTRIC IMMERSION HEATER
PACKAGE THREE PHASE
ELECTRIC HEATER
WIRING DIAGRAM
BAC 6988 B
C
BAC- 11490A
20000Baltimore Almon Compaq. NI Rights Reserved.
OPERATING INSTRUCTIONS
Follow the installation drawings and wiring diagram (see chart below) to ensure the proper
operation of the vibration switch. Direct any questions to your local BAC Representative.
NOTE
Moisture inside the switch can lead to switch failure. Care must be taken when replacing
the cover on the vibration switch to ensure that the proper watertight seal is obtained.
CAUTION
Before performing any maintenance, adjustment or inspection of the switch, make certain
that all power has been disconnected and locked in the off position.
WIRING DIAGRAM CHART
BAC- 17491A =Shut down with local reset
BAC- 17492A =Shut down & alarm, with remote or local reset & time delay on start (110 Vac)
BAC- 17493A =Shut down & alarm, with remote or local reset & time delay on start (220 Vac)
GUARD
(REMOVED
SWITCH LOCATION
LOW PROFILE SERIES V
MOUNTING
BRACKET
VIBRATION
CUTOUT
SWITCH
B.A.C.
ORDER NO: U070805601
DATE: 03/14/07
SWITCH LOCATION
SERIES V
0
VIBRATION
CUTOUT
Q SWITCH
BALTIMORE AIRCOIL
COMPANY
MECHANICAL VCOS LOCATION
CENTRIFUGAL FAN UNITS
BRAVING NUMBER:
BAC- 11490A
BAC-17491A
20000 BalUmors Aircop Company. AN RIO* Reearet I
NOTES;
1. LOCAL PUSH BUTTON RESET.
2. TO MAINTAIN HAZARDOUS DUTY RATINGS, THE FACTORY INSTALLED WATER TIGHT CONDUIT /CABLE CONNECTION FITTINGS MUST BE
REMOVED AND THE FOUR CONDUCTOR CABLE MUST BE ROUTED INSIDE OF A SUITABLE EXPLOSION PROOF CONDUIT. NOTE: THE
CONNECTORS CAN EASILY BE REMOVED WITHOUT HAVING TO UN -WIRE THE CONDUCTORS FROM INSIDE THE CUTOUT SWITCH.
3. THE MECHANICAL VIBRATION CUTOUT SNITCH COMES WITH TWO WATER TIGHT CONDUIT /CABLE CONNECTORS. ONE CONNECTOR IS
USED TO PROVIDE A WATER TK;HT CONNECTION TO THE VIBRATION CUTOUT SWITCH AND THE OTHER IS PROVIDED FOR THE
ELECTRICIAN TO CONNECT THE WIRE CABLE TO A JUNCTION BOX LOCATED IN THE VICINITY OF THE VIBRATION CUTOUT SWITCH.
4. THE SWITCH IN THE NORMALLY CLOSED CIRCUIT (BLACK WIRE) WILL OPEN WHEN THE DEVICE EXPERIENCES VIBRATION LEVELS
ABOVE THE SETPOINT VALVE. IF REVERSE CONTROL LOGIC IS DESIRED, CUT OFF THE BUTT END CONNECTOR ON THE WHITE
WIRE AND INSTALL A WIRE NUT OR BUTT CONNECTOR ON THE NORMALLY CLOSED WIRE (BLACK).
5. THIS MECHANICAL VIBRATION CUTOUT SWITCH COMES WITH ONE SINGLE POLE DOUBLE THROW SWATCH. THE SWITCH CONTACTS ARE
'DRY CONTACTS' WHICH CAN BE SUCCESSFULLY USED DIRECTLY IN THE FAN STARTER CONTROL (TYPICALLY A/C VOLTAGE)
CIRCUIT OR DIRECTLY IN A BUILDING MANAGEMENT SYSTEM (TYPICALLY D/C VOLTAGE).
CONTACT RATINGS: 3 AMPSO 125 OR 480 VAC, 1/2 AMPO 125 VDC, 1/4 AMPO 250 VDC.
B. CAUTION: MOISTURE INSIDE THE SWITCH CAN LEAD TO SWITCH FAILURE. CARE MUST BE TAKEN WHEN REPLACING
THE COVER ON THE VIBRATION SWITCH TO ENSURE THAT THE PROPER WATERTIGHT SEAL IS OBTAINED.
ADJUSTMENTS OF BAC MECHANICAL VIBRATION CUTOUT SWITCH
BAC RECOMMENDS THAT EACH VIBRATION CUTOFF SWITCH BE FIELD ADJUSTED AT START -UP TO OPTIMIZE THE TRIP POINT RELATIVE
TO THE FINAL MOUNTING POSITION AND VIBRATIONAL CHARACTERISTICS OF THE INSTALLED EQUIPMENT.
NOTE: INSTALLATION AND ADJUSTMENT MUST BE PERFORMED BY A QUALIFIED, COMPETENT TECHNICIAN
1. FOR SAFETY SAKE, TURN OFF, THEN LOCK & TAG -OUT THE ELECTRICAL SUPPLY TO THE FAN MOTOR(S).
2. TURN ADJUSTMENT SCREW COUNTERCLOCKWISE (CCW) 1/8 TURN AT A TIME UNTIL YOU HEAR THE CONTROL TRIP.
3. ONCE TRIPPED, ROTATE ADJUSTMENT SCREW 1/4 TURN CLOCKWISE (CW) AND THEN PUSH IN MANUAL RESET BUTTON.
4. START UP FAN(S) TO DETERMINE IF THE START -UP WILL CAUSE THE CUT -OUT SNITCH TO TRIP.
5. IF THE VIBRATION CUTOUT SWITCH DOES NOT TRIP, THEN START AND STOP THE FAN TWO MORE TIMES AND IF THE CUTOUT
SWITCH STILL DOES NOT TRIP, THEN CAUBRATION IS COMPLETE. IF THE VIBRATION CUTOUT SWITCH DID TRIP, THEN TURN
OFF, THEN LOCK & TAG -OUT THE ELECTRICAL SUPPLY TO THE FAN MOTOR(S). ADJUST THE SET POINT SCREW AN
ADDITIONAL 1/4 TURN CW AND THEN DEPRESS THE RESET BUTTON. RE -START THE FANS) TO DETERMINE IF THE START -UP
WILL CAUSE THE SWITCH TO TRIP. REPEAT THIS ADJUSTMENT PROCESS UNTIL THE CONTROL DOES NOT TRIP. ONCE NE
FINAL ADJUSTMENT HAS BEEN MADE, START AND STOP THE FAN TWO MORE TIMES AND IF THE CUTOUT SWITCH STILL DOES
NOT TRIP, THEN CAUBRATION IS COMPLETE.
B.A.C.
ORDER N0: U070805801
DATE: 03/14/07
MECHANICAL VIBRATION CUT -OUT SWITCH
(ONE— SINGLE POLE DOUBLE THROW SWITCH)
SETPOINT ADJUSTMENT
7' FLEXIBLE
JACKET
CUSTOMER
WIRES
(FOR HAZARDOUS
RATINGS SEE
NOTE 2)
WATER PROOF
CONDUIT CONN
(SEE NOTE 3)
LOCAL RESET
(SEE NOTE 1)
WATERTIGHT
SEAL
(SEE NOTE 6)
MOUNTING PLATE
WIRING DIAGRAM
(ONE — SINGLE POLE DOUBLE THROW SWITCH — SEE NOTE 5)
TO CUSTOMER FAN
CIRCUIT OR BUILDING
MANAGEMENT SYSTEM
(SEE NOTE 5)
(SEE NOTE 4)
a (WHITE)
(RED)
(BLACK)
(GREEN)
9 N.O.
COMMON
Eti N.C.
BAC PART# 311788
CASE GROUND
BEFORE PERFORMING ANY MAINTENANCE, ADJUSTMENT OR INSPECTION OF THE
SWITCH, MAKE CERTAIN THAT AU. POWER HAS BEEN DISCONNECTED AND LOCKED
IN THE OFF POSITION.
SHUT OFF WITH LOCAL RESET
BALTIMORE AIRCOIL
COMPANY
MECHANICAL VCOS
WIRING DIAGRAM
ORA tONO NtM
BAC- 17491A B
ACTIVITY NUMBER: M07 -059 DATE: 03 -23 -07
PROJECT NAME: TUKWILA COMMERCE CENTER
SITE ADDRESS: 631 STRANDER BL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: � AIG 3, Zi.D1
Building
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
DUE DATE: 04-24-07
Approved n Approved with Conditionslil Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2 -28-02
►� PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Fire revention
Structural
Incomplete ❑
Planning Division
❑ Permit Coordinator
DUE DATE: 03-27-07
Not Applicable C
No further Review Required
DATE:
DATE:
n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
PROSTMI072NG
Licensee Name
PRO STAFF MECHANICAL INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601038859
Ind. Ins. Account Id
52073600
Business Type
CORPORATION
Address 1
PO BOX 33370
Address 2
City
SEATTLE
County
KING
State
WA
Zip
98133
Phone
2063610071
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
8/7/1993
Expiration Date
6/30/2008
Suspend Date
Separation Date
Parent Company
Previous License
PROSTHA 136NJ
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
ALMO, LEONARD L
PRESIDENT
08/07/1993
Bond
Amount
ALMO, PENNY
VICE PRESIDENT
08/07/1993
103645389
Bond Information
Bond
Bond Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#7
TRAVELERS
CAS &
SURETY CO
103645389
08/07/2001
Until
Cancelled
$12,000.00
07/30/2001
Swv
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= PROSTMI072NG 04/10/2007
•
,— 15.403 SF.
5' SETBACK
GM
60' NIDE
SETBACK
BLDG A
10.564 SF
BLOC E
SF:
BLDG B
9.826 SF.
11,701 SF.
312.25'
10' UTILITY ESMT
SL
tilt;
3.2'6
0.8'
0.6' AIMS: IF I I F 1 R,
t. M - =
la
Bnite
Roc* It
Purr
ROOM
2.7'
1.2' 588111'
127.
'0' ROCKERY
Gil
TRACT 2
S TR�4 NDER - BL VD
48 ?.7
397.81'
n 10 .. N1 DE
ry ESAI
58875'33'£
46Z69'
.• •a•
Parcel Number: 023300020
BAC
(Baltimore Air Cod)
FOUND 1' IRON PIPE
w/ CAP FAR PLUG
LS/11568
N40- 23 -33E 0.42'
7/31/00
SCALE: l" =50'
SITE PLAN
EOUIPMIE?T NOTES:
I) en Certified Thermal Performance.
2) ISO 9000/9001 Certified Manufacturing Plant
3) G235 Galvanized Steel Coostroction
4) 7% HP Inserter Duty Premium Efficient Fan Motor.
5) Float Water Level Control Package.
6) Electric Emersion Heaters and Controls.
7) Mechanical Vdiration Cutout Switch.
8) Seismic Zone.' IBC 1997 Unit Anchorage.
9) Existing Model being replaced: B.A.0 B S'NT - -70B
5' SETBACK
REPLACE EXISTING COOLING
TOWER WITH NEW.
"LIKE- FOR - LIKE" REPLACEMENT
/ TIIE COOLING TOWER IS LOCATED
ON THE GROUND WITHIN IT'S
t COOLING TOWER ENCLOSURE.
COOLING TOWER ENCLOSURE
SCALE: % " =1' -0"
COOLING TOWER REPLACEMENT EQUIPMENT SCHEDULE
OPERATEt \G
I TAG I MAKE I MODEL# Certified Capacity I Fan Motor ELECTRICAL WEIGHT
LBS
V 0-65.1 j 210 UJSGPM 73 HP i 460.3'60 2, E
588191' : 5'E
306.53'
•
0.7' N.
1.6'
Fig
FOUND 1' IRON PIPE
W/ ORANGE PLUG
N74- 31 -47E 0:33'
7/31/00
•
•
•
•
REPLACE EXISTING COOLIN
TOWER WITH NEW.
"LIKE- FOR - LIKE" REPLACEMENT
THE COOLING TOWER IS LOCATED
ON TILE GROUND WITHIN IT'S
COOLING TOWER ENCLOSURE.
- — -
•
•
1
•
•
•
•
N
N
ASPHALT
PATH
1
FOUND 3/4' /ROM
PIPE w/ PLUG :
S72- 28 -02E 0.18'•
8/17/00
1
FOUND 3/4' IRON
PIPE w/ PLUG
N60- 52 -17E 0.11
8/17/00
•
•
•
COOLING TOWER REPLACEMENT SCOPE OF WORK:
♦ Supply & install one new BAC cooling tower Model II VTO -65 -J in the same
location. This is the BAC filctoiy recommended replacement /equivalent for
the existing tower.
♦ Reconnect to the existing water loop piping, domestic water supply piping,
and drains.
♦ Refill, start-up and test operation of tower.
♦ Includes crane, rigging, and equipment transportation.
♦ Removal and disposal provisions.
♦ Mechanical permit and drawing.
g G•'6 Pt
City of Tukwi!a
BUILDING DIVISION
I-
VICINITY MAP
Plan review approval Is subject to errors and om
Approval cons�x� documents does not authorize
violation of en./ ccorwj • 0 or a approved Fw,:; ordinance. Rem Zorn Is admaviedgid:
i
r "lirs S
C� itad3t,C:oc .V.7.7
• :. _ r::T �.� ,...c :1 c7
I►G. C: Will uire a new Wan
�.�,,/ m4 l; nlbm;t�l
and may Include addftlonal plan review fees.
PacHk Gull Business Park
Tara I
U
�� 1lJkWlla
DIVISION
R EVIEWED Ol= R
COD COMPLIANCE
MAR 2 8 zoo/
tY Of Tuk
BUILDING 9IVISIO V
Phase IV
Phase Y
•
OFFICE
Blvd.
4
COOLING
TOWER
LOCATION
REVISIONS
SHEET
NUMBER
JOB #1191
a
C
4 M •
c s • o►
c
'C u)
i � g
0. N C
E O
N 2 m
0.121
E
0
H
z
U �
0.4 454
a� sae
�,A3
WO a
0
;11 E e i
a
6
o�
0
c�
DRAWN PG
DATE 3Ai/o7
CONTENTS ,
nJ
'�• - + lttit
M -1
Am*-Gs1
1