HomeMy WebLinkAboutPermit M07-063 - NW JANITORIAL SUPPLYNW JANITORIAL SUPPUES
1083 ANDOVER PK E
M07 -063
Parcel No.: 2623049106
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
City of Tukwila
1083 ANDOVER PK E TUKW
NW JANITORIAL SUPPLY
1083 ANDOVER PK E , TUKWILA WA
SECURITY CAPITAL INDUSTRIAL
C/O DELOITI E & TOUCHE LLP , 2235 FARADAY AVE STE 0
CARRIE BOYD
9630 153 AV NE , REDMOND WA
Contractor:
Name: MERIT MECHANICAL INC.
Address: PO BOX 2109 , REDMOND, WA
Contractor License No: MERITNII163CM
DESCRIPTION OF WORK:
REPLACE (1) EXISTING ROOF TOP UNIT WITH A NEW RTU
Value of Mechanical: $6,900.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
MECHANICAL PERMIT
EQUIPMENT TYPE AND OUANTITY
0
0
0
0
0
1
0
0
0
0
0
0
0
0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Steve Lancaster, Director
Phone:
Phone: 425 602 -4372
Phone: 425 883 -9224
Expiration Date: 06/01/2007
Steven M. Mullet, Mayor
M07 -063
04/12/2007
10/09/2007
Fees Collected: $235.00
International Mechanical Code Edition: 2003
Boiler Compressor:
0-3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15-30 HP /1,000,000 BTU.. 0
30 -50 HP/1,750,000 BTU.. 0
50+ HP/1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 1
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment 0
doc: IMC -10/06 M07 -063 Printed: 04 -12 -2007
Permit Center Authorized Signatur
I hereby certify that I have read an
governing this work will be complie
The granting o + 's pe t does not pre
construction , r the pe ormance of wor r
Signature:
Print Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
Permit Number: M07 -063
Issue Date: 04/12/2007
Permit Expires On: 10/09/2007
th,
Steven M. Mullet, Mayor
Steve Lancaster, Director
Date: 0 11
permit and know the same to be true and correct. All provisions of law and ordinances
er specified herein or not.
ve authority to violate or cancel the provisions of any other state or loc laws regulating
ed t • sign and obtain this mechanical permit.
Date:
This permit shall become null and void if the wo k is not commenced within 180 days from the date of issuance, or if the work is suspendec
or abandoned for a period of 180 days from the last inspection.
doc: IMC - 10/06 M07 -063 Printed: 04 -12 -2007
Parcel No.: 2623049106
Address:
Suite No:
Tenant:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
13: ** *FIRE DEPARTMENT CONDITIONS * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
1083 ANDOVER PK E TUKW
NW JANITORIAL SUPPLY
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Readily accessible access to roof mounted equipment is required.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
M07 -063
ISSUED
03/30/2007
04/12/2007
10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
15: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
doc: Cond -10/06 M07 -063 Printed: 04 -12 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
16: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
19: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
21: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this
project.
22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
* *continued on next page **
doc: Cond -10/06 M07 -063 Printed: 04 -12 -2007
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the p: • • ance of work.
Signature:
Print Name:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Date: /
M07 -063 Printed: 04 -12 -2007
Site Address: I
Tenant Name:
Property Owners Name:
Mailing Address:
Name:
E -Mail Address:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Li f vt I
CITY OF TUKWIL,,
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Mailing Address: 91_Q, - 6O
q:\ \permits plus\icc changes \permit application (7 -2004)
Revised: 6 -8 -05
bh
P}ndOVairPwlk
lS
ex c F ' Carl. ( ctj Y1.Q .
Page 1
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.:
Ke . b
City
94.1c0 - 11 oti
Suite Number: Floor:
New Tenant: ❑ Yes ❑..No
State
State
6 D032,
Zip
CONTACT PERSON
Day Telephone: AM S _ CPO p-
ged mane �� q g152_,
City �T
Fax Number: (i� �( Sttate ��
GENERAL CONTRACTOR INFORMATION (Mechanical Contractor information on back page
U� :I
9
City State ? Zip
Day Telephone: 42S - ( 0 OL t ?FfL
CC.NFax Number: - — ('
Contractor Registration Num er: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
ARCHITECT OF RECORD - All plans must be w'et stamped by Architect of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Zip
ENGINEER OF RECORD' All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace<100K BTU
Air Handling Unit >10,000
CFM
e5
Fire Damper
0-3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig /Cooling
System
I
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator – Comm/Ind
Other Mechanical
Equipment
MECHANICAL PERMIT INF n VIATION - 206- 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address: CtLQ,
Contact Person:
E -Mail Address:
{ 0 Day Telephone: -47 - (
( Fax Number: 4 Zs - vs2.. -() Ca Z
Contractor Registration Number: 4 '�1�2��(1 Expiration Date: � - I- Ot
* *An original or notarized copy o c urrent Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: N .... ❑ Replacement ...�
Fuel Type:
BUILDING
Signature:
Print Name:
Mailing Address:
Electric
OR
q: \\permits plus\icc changes \permit application (7 -2004)
Revised: 6 -8 -05
bh
r e)t)i, rA
0
Indicate type of mechanical work being installed and the quantity below:
edon
mA IVA 6 N)54 -
City State Zip
r
oc
kX Asi o
r R
Gas.... Other:
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF • RJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
• S -AZWAININ
AUTHO' _ NT:
Date Application Accepted: � Io I DI —
Page 4
Date: - 30-0‘4
Day Telephone: - vn - (Q - y' - Yt
City
State
Zip
5�
Date Application Expires:
Staff Initials: ,
i
Receipt No.: R07 -00555
Initials: JEM
User ID: 1165
Payee: MERIT MECHANICAL, INC.
ACCOUNT ITEM LIST:
Description
MECHANICAL - RES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049106 Permit Number: M07 -063
Address: 1083 ANDOVER PK E TUKW Status: APPROVED
Suite No: Applied Date: 03/30/2007
Applicant: NW JANITORIAL SUPPLY Issue Date:
TRANSACTION LIST:
Type Method Description Amount
Payment Check 23041 194.00
Account Code Current Pmts
000/322.100 194.00
Total: $194.00
Payment Amount: $194.00
Payment Date: 04/12/2007 09:14 AM
Balance: $0.00
7051 04/12 9716 TOTAL 194.00
doc: Receiot -06 Printed: 04 -12 -2007
Receipt No.: R07 -00470
Initials: JEM
User ID: 1165
Payee: MERIT MECHANICAL, INC.
TRANSACTION LIST:
Type Method Description
ACCOUNT ITEM LIST:
Description
PLAN CHECK - RES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049106 Permit Number: M07 -063
Address: 1083 ANDOVER PK E TUKW Status: PENDING
Suite No: Applied Date: 03/30/2007
Applicant: NW JANITORIAL SUPPLY Issue Date:
Amount
Payment Check 23018 41.00
Account Code Current Pmts
000/345.830 41.00
Total: $41.00
Payment Amount: $41.00
Payment Date: 03/30/2007 11:50 AM
Balance: 5194.00
doc: Receipt -06 Printed: 03 -30 -2007
�Cri / �
::::
y ➢e o nspecton:
� t 1 �
'
s: ,
/0g3 ,f14-
ate lied:
r
Special Instructions:
a.
Date Wanted:
a.m.
Requester:
Phone No
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206)431- 6 0
COMMENTS:
0
Approved per applicable codes. ❑ Corrections required prior to approval.
$58.00(RE" FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
Project:
WI,
/
Type of Inspection:
7of / .4 1, 4
, ;h
Address:
/.
,// //--
/4 Per - �
Date Called:
Special Instructions:
i
Date Want � ,
,
p.m.
Requester:
Phone No
INSPECTION RECORD ,
Retain a copy with permit
INSPECTION O.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
COMMENTS:
;e4\ v a
NA-
� 'S /14
Date:
(206)431 -367
Approved per applicable codes. Corrections required prior to approval.
$58.00 REINSPECTth FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
'Receipt No.:
'Date:
COMMENTS:
Type of Inspecti n:: c4
Address: /1)0 3 4
Suite #:
Contact Person:
Special Instructions:
Phone No.:
2 5 3 - 2s4 - -vD'e
Permits:
Occupancy Type:
C ) 7.?- m,g7e- U41-01,1 Pit/ 0 /L-
e)
7 vc -r 2> . 7Z-Z'T - 0 l-� D
co)
e- t`7w p--
E✓ACQ T'Ac)4CL. SMO Lc_ .. 61L-
4—
6 N 4t OIL
MofiA(;,-7,;.i,- .( /2t /Z„ ...
Project: 4p c j>>C
Type of Inspecti n:: c4
Address: /1)0 3 4
Suite #:
Contact Person:
Special Instructions:
Phone No.:
2 5 3 - 2s4 - -vD'e
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
oY- F - 35 -
PERMIT NUMBERS
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Approved per applicable codes.
n Corrections required prior to approval.
......gi
Inspector:
kilwbi/stz_
Date: 8 17 10
Hrs.:
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
,lath City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc
1/13/06
T.F.D. Form F.P. 113
Pier)
NW JANITORIAL SUP':Y- PROLOGIS
MECHANICAL UNIT SUPPORT..
L-
1083 ANDOVER PARK EAST
TUKWILA, WASHINGTON 98188
STRUCTURAL CALCULATIONS
MARCH 22, 2007
JOB NO: 106 -0701
[EXPIRES ) /
Me co
P ew: fi No.
•
Lincoln Center Business Park
555 116th Ave. NE, Suite 150
Bellevue, WA 98004
Phone 425.644 -6400
Fax 425.644 -0463
REVIEWED FOR
CODE COMPLIANCE
-
A nrnwr1Vc0
APR - 5 2007
---646
- Of Tukwila
BUILDING DIVISION
J:
RED
CITY OF TUKWILA
MAR 3 0 2007
PERMIT CENTER
C,
a te
(Z95 )hs)
PARTIAL ROOF FRAMING PLAN
aroNct/S peu
)e'P 0,05y3-
NOTES:
1) CONTRACTOR TO VERIFY ALL SIZES, DIMENSIONS. AND LOCATIONS AT FIELD.
2) CONTRACTOR TO VERIFY ALL EXISTING ROOF FRAMING MEMBER SIZES.
3) CONTRACTOR TO VERIFY MECHANICAL UNIT SIZE, WEIGHT AND LOCATIONS.
4) LOCATE ONE END OF THE UNIT OVER THE GLU- LAMINATED BEAM.
-4A
r
Shoot No.
)
Dole JoX No.
7•'" ! !0! —°7°
v
a
7y) ELE r.9�a ✓rte �/
JectiSubfocl
, ,,.% .1/9
a 0 3 9r
ve., / > ox.a
Gv �g yr /Cef-) - Jo
sag- 2P& (7 5 )
6) - jo sce6%--0
Efl, f/pE /l'
Ox J1 G C ✓6. .eih)
1- Y) # 1 Go'
g o " o ,G, ex
Dose
3 -z,-
No.
/ z
,&,/-e,794
ROOF LOADS:
DEAD LOAD:
B.U. ROOFING 2 PSF
PLYWOOD 1.5
.2x4 @ 24" o.c. 0.7
SPRINKLER 2
INSULATION 1
PURLIN 1.5
CEILING 1.5
MISC. / MECH. 1.8
12 PSF
LIVE LOAD:
SNOW 25 PSF
TOTAL LOAD: 37 PSF
MECHANICAL UNIT DATA:
HP -IA = 795 lbs (including curb)
vro
'
Sheet No.
Dale Job No
3 —z 2- - d 1oG -oTo 1
fWeL '
GG� y lie
b.ro...� G % 4-3 �s )1 1 Z
E Xosr, )w//,.r 4- x) - p 4i I
CL 5 A.'"
(A oice,, pi;
J�- ,l,.xJ
d x l o L i d J ` f ' 4-4- ,W('
—
)c. ) , 1 >)( 9'd ig moo, oy'
= 0' 77 `
z�9
' - I
log, ,9 sZ ✓e.' 7,14 Ems'
19.
Sheet No.
Date Job No. •
3 - 22 -o l0G -o7a
oN oor
AN
O
2( g�����x�
Po!ans/ioatwd
%y2 79 a ( 7 '1
(Loo —27 '0 z A
2 f'o 9.7g ( a '
jff 757
,7d <75- _ $/ C-2/40 5722
/7d (-3
o g
LATERAL DESIGN:(IBC 2003, ASCE 7-02)
(A) WIND -
BASIC WIND SPEED = 85 MPH (FIG. 6-1, ASCE 7 -02)
EXP. "B"
Iw= 1.0
Kd = 0.9 (TABLE 6 -4, ASCE 7 -02)
Kz = 0.7 UP TO 30'
Kzt= 1.0 (TABLE 6-4, ASCE 7 -02)
Gf = 0.85 (GUST FACTOR)
qz = 0.00256 x Kz x Kzt x Kd x VA2 x I (EQ. 6 - 15)
qz = 11.7 PSF
Cf = 1.3 (FIG. 6-19, ASCE 7 -02, H/D < 1.0, FOR MECHANICAL UNIT,
F= qzxGfxCfxAf (EQ.6 - 25)
F = 12.88 Af
UNIT LENGTH (L) = 6.2 FT
UNIT WIDTH (W) = 3.75 FT
UNIT HIGHT (H) = 3.5 FT
SHORT DIRECTION: F wind = 363 lbs
LONG DIRECTION: F wind = 220 lbs
jecVSubject
Sheets.
% )
ENO.
� a 4 4- O70 I
Vd=C CU IU I III le. J/L IILUUI 't.'ta.vi rive
MCE Ground Motion - Conterminous 48 States
Zip Code - 98188 Central Latitude = 47.447736
Central Longitude = - 122.273462
Period MCE Sa
(sec) ( %g)
0.2 133.7 MCE Value of Ss, Site Class B
1.0 046.0 MCE Value of S1, Site Class B
Spectral Parameters for Site Class D
0.2 133.7 Sa = FaSs, Fa = 1.00
1.0 070.8 Sa = FvS 1, Fv = 1.54
SEISMIC (2003 IBC)
ZIP CODE: 98188
LATITUDE = 47.45
LONGITUDE = - 122.27
Ss = 1.337 g
81 0.46g
SITE CLASS "D"
SDC = D
SEIMIC USE GROUP = 1
Fa= 1
Fv = 1.54
Sms = Fa x Ss = 1.337 g
Sm1 = Fv x S1 = 0.71 g
Sds = 2/3 Sms = 0.89 g
Sd1 = 2/3 Sm1 = 0.47 g
Fp = (0.4 Ap.Sds.Wp/(Rp/Ip)) / (1 + 2 ZJH)
Ap = 1
ip = 1
Rp = 2.5
Sds = 0.89
(EQ. 9.6.1.3 -1)
Rojxvswiect
BY
Dale
Sheet No.
Job No.
,b6,o7o
ZIH= 1
Wp = 795 lbs
Fp = 340. lbs
Fp (MAX) = • •1.6 Sds.Ip.Wp = 1,134 - lbs > Fp O.K.
Fp (MIN) = 0.3 Sds.lp.Wp = 213 lbs < Fp O.K.
Fp (ASD) = Fp / 1.4 = , 243 lbs
(WIND GOVERNS IN SHORT DIRECTION)
CHECK UNIT STABILITY:
S HORT DIRECTION:
F(wind) = 363 lbs
M (O.T.) = 636 lbs-ft
M (REsis.) = 1491 lbs-ft
0.70 M (R)= 1043 lbs-ft > M (O.T.)
F(wind) / #10 SCREW= 45 lbs - O.K.
pcv&,Dpa
)o8 3 #9 - e `/,6
NO UPLIFT
USING: MINIMUM (4)410 SCREWS EACH SIDE OF THE UNIT / CURB
Date
eZ
Sheet "°9 v
J
/o6�o7d
APPENDIX
A4
6' -- o"
Ge'• e° 3
G x 5 / 160 i tE
:;
H 4
n
6'Q • L6't
41 J4 •lr 4 &M.
•6ZI. 0"
w64 X 51):160
DO
D o
G8 J
.5(11.x Z 7
(.-•)
.. Ga 11
41
ad
•
:A233); BENDS Ill REBAR TO BE WELDED SHALL NOT BE CLOSER 3" TO WELD.
STRUCTURAL STEEL
STRUCTURAL STEEL SHALL CONFORM TO THE ING STwIDARDS:
TUBE COL. ASTSI A501 -68a (fr- ,00 I)
ALL STEEL MEMBERS SHALL BE GIVEN P COAT OF APPROVED PAINT. WELDING
AS PER PARAGRAPH BELOW.
MISCELLANEOUS STEEL
MISCELLANEOUS STEEL SHALL CONFORM TO AST11 A -36 (fy =36,000 PSI). WELDS NOT
SPECIFIED SHALL BE 1/4" CONTTINUOUS FILLET MINIMUM. ALL WELDS TO BE BY
CERTIFIED WELDERS -- USE FRESH E60 ELECTRODES.
MISCELLANEOUS HANGERS TO BE_NUESOULOR APPROVED EQUAL. ALL HANGERS TO BE
FASTENED TO WOOD WITH PROPER NAILS -- ALL HOLES SHALL BE NAILED. MACHINE
BOLTS TO BE A -307. ANCHOR BOLTS INTO CONCRETE MAY BE PARA - BOLTS, KW1K BOLTS
OR APPROVED EQUAL; MINIMUM EMBEDMENT PER UBC TABLE 26 -1. FABRICATOR MAY
INCREASE PLATE SIZE PROVIDED HE COORDINATES THIS WITH ALL TRADES CONCERNED
AND OBTAINS ENGINEER'S APPROVAL.
TIMBER
ROOF JOISTS
4x PURLINS
LUMBER NOT NOTED TO BE
D.F. #1
D.F. #1
D.F. #2
( fb =1650 PSI) " T
f PSI)
ALL GRADES SHALL CONFORM TO 'WUPA GRADING RULES FOR WESTERN LUMBER -- 1970
EDITION." DOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH
STANDARD CUT WASHERS. ALL WOOD III CONTACT WITH CONCRETE SHALL BE TREATED.
GLU - LAMINATED WOOD MEMBERS
GLU- LAMINA TEED WOOD , DOUGLAS FIR COAST REGION, KILN DRIED, STRESS
GRADE COMBIIIATIOt Z4F b =2400 PSI). GLUE SHALL BE CASEIN WITH MOLD INHIBI-
TOR. BOTTOM LAM BE FREE OF UNSOUND KNOTS LARGER THAN 1/2" DIAMETER.
GLU -LAM FABRICATOR TO PROVIDE TOP TENSION LAMS AT CANTILEVER. MATERIALS
MUST BE OBTAINED•FROM' AN APPROVED FABRICATOR.
PLYWOOD •
1 2" STRUCTU1 L I OH ROOF (UBC IDENTIFICATIOt1 INDEX 32/16). NAILING SHALL
BE AS INDICATED OH PLAN. CONTRACTOR IS TO CALL ENGINEER FOR INSPECTION OF
ROOF DIAr'IIRAGM PRIOR TO ROOFING. .
PRECAST WALLS
PANEL LIFTING STRESSES ARE TO BE CUECKED BY THE CONTRACTOR AND HE SHALL
PROVIDE REINFORCING STEEL AS REQUIRED FOR HIS METHOD OF HANDLING AND EREC-
TION OF PRECAST PANELS. USE STRONG - BACKS AS REQUIRED AT EXCESSIVE PANEL
OPENINGS. COHTINUOUS'FILLET BETWEEN PANELS AND FOOTiNGS TO BE A NON- SHRINK-
ING TYPE.
SPECIAL CONDITIONS
CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD, AND SHALL PROVIDE ADEQUATE
SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. CON-
TRACTOR SHALL NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION.
.CONCRETE FOR PRECAST WALLS SHALL BE SUPERVISED.
INSPECTIONS ✓
CONCRETIMIK AND STEEL PLACING (NOT INCLUDING SLAB ON GRADE) IS TO BE
INSPECTED BY All APPROVED TESTING LAD. ALL PHASES OF LOIISTRUCTIOH SHALL BE
INSPECTED BY THE CITY OF TUI'WILA BUILDING DEPARTMENT.
SHOP DRAWINGS
TTONT1'T ETS OF SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION FOR: GLU -
LAMS, MISC. EIIBEDED ITEMS A40 REINFORCING.
•
w
DEPARTMENTS:
Buing ivision
Public Works
Complete
Comments:
Please Route
TUES/THURS ROUTING:
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2-28-02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M07 -063 DATE: 03 -30 -07
PROJECT NAME: NW JANITORIAL SUPPLY
SITE ADDRESS: 1083 ANDOVER PK E
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
Structural Review Required
Ot AW ('
Fire Prevention
Structural ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete ❑
C
DATE:
DATE:
Planning Division
Permit Coordinator
n
DUE DATE: 04-03-07
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required
C
DUE DATE: 05-01-07
Approved with Conditions 1 Not Approved (attach comments) n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
KIRKWOOD, RODERICK V
PRESIDENT
02/14/1984
Bond
Amount
KIRKWOOD, JOAN M
SECRETARY
02/27/2006
FRICKBERG, WILLIAM
MICHAEL
VICE
PRESIDENT
02/27/2006
Bond Information
Bond
Bond
Company
Name
Bond Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
Licensee Name
Licensee Type
UBI
Ind. Ins. Account Id
Business Type
Address 1
Address 2
City
County
State
Zip
Phone
Status
Specialty I
Specialty 2
Effective Date
Expiration Date
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
MERITMI163CM
MERIT MECHANICAL INC
CONSTRUCTION CONTRACTOR
600517946
46817500
CORPORATION
PO BOX 2109
REDMOND
KING
WA
980732109
4258839224
ACTIVE
GENERAL
UNUSED
2/14/1984
6/1/2007
AUTOMMC044QH
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MERITMI163CM 04/12/2007
r 1
4`
•
•
EAST ELEVATION
0 SCAM 1/16' r - 4t'
MERIT MECHANICAL.
9630 153RD AVENUE NE
P.O. BOX 2109
REDMOND, WA 98073 -2109
FAX (425) 8 7?0962
LICENSE: MERITMI163CM
REVISIONS
. ISSUED RR PEAR 03 -27 -07
CHECKED
DATE
SHEET TITLE
VTD
AEA
03 -16 -07
JOE MAR
807314
HVAC PLAN itt
SCHEDULES
SHEET NUMBER
M -0.1
ROOFTOP HEAT PUMP UNIT SCHEDULE
TAG
IV-TA
MAKE L MODEL
CARER 50IUQ007 -6 6 TON
DESCRIPTION
ROOFTOP HEAT PUMP UNIT
SA OSA
2400 500
ESP
1.0
FM
RPM HP ERNE
1435 3 I BELT
NOISE COOLING, MOH HEATING,, MOH
dER
80
TOTAL/SENS. Earn
78.5/56.9 10.5
II
48.5
COP
3.4
KW
14
STAGE
2
ELECTRIC&
VOLT PH
MCA 1lOCP
I 36.2 40
795
REIVMCS
1.2.3
ROTE 1. EQUIPMENT MAY BE SUBSIRUIEO FOR EQUW. OR BETTER WNUFACiURER.
2. LOYN/I♦I PRESS SNUCK CRANKCASE HEATER, HIGH STATIC ERNE MOTOR.
3. ECONOMIZER W/ BAROMETRIC REU F. REUSE DOSING CURB & SMOKE DETECTOR
EXISTING ROOFTOP HEAT PUMP UNIT SCHEDULE
TAG
IV-1
NOTE 1. LOW/HI PRESS SWATCH. CRANKCASE HEATER. CURB.
3. SMOKE DETECTOR. ECONOMIZER
GENERAL NOTES
f'
II •I
-.
MAKE a MoOEL
CARRIER 501J0007 -6 6 TON
40'-9'
DESCRIPTION
EASING ROOFTOP HEAT PUMP IRNT
I. COORDINATE ROOFTOP HEAT PIMP UNT MIN STRUCTURE MD OTHER TRADES.
2. HNC EQUIPMENT TIMIS AND LOCATIONS TO DE WPROVED BY
STRUCTURAL ENGINEER.
I FRO WILY UNIT LOCATIONS. DROPS. MD POSITIONS.
4. WNNIIW 10' -0' UHMUU DISTANCE BETWEEN O.SA NETS
MD PLUMBING WASTE VENTS, ETOWUSIS,, MD COMBUSTION
AR OUTLETS.
5. SEAL. ALL TRANSVERSE DIUCT JOINTS
6. A 120 -VOLT RECIPTAME SHALL DE VIHIHN 25' OF EACH
PEACE OF EQUIPMENT.
7. SMOKE DETECTOR WIRE BY EIECIRIL'WN. CONTROL BY FIRE MD TEE SEER.
a ALL LIE VOLTAGE BY ELECTRON.
9. ML F1RE/SMOHOE DAMPERS MD SMOKE °RECTORS TO DE POAETS ° BY OTTERS.
10. TILL DUCT MOUNTED SMOKE DETECTORS SHWL BE SUPPLED MD INSTALLED
BY THE MIECHANIC . CONTRACTOR.
11. AREA SMOKE DETECTORS SHALL BE INSTALLED MINN 5 FEET OF Iii//SMOKE
DAMPER BY OTHERS MD POWERED BY OTHERS WHEN NO GLOBE SMOKE
DETECTION SYSTEM COSTS.
12. CONDENSATE DRAINS TO BE DISCHARGED ON SPASM BLOCKS.
•
•
r4
i
SA
2400
OSA
500
ELECTRICAL
VOLT/P11/11Z
460 -3 -60
WEIGHT
LBS
755
REMARKS
1, 2
l
g
N
L
- - -2'-8 1/16' -•
5 /8'-1
L
UNIT 1D0UF -3'-5 5/16'
7/8"
5
6' -1 11/16'
DIMENSIONS FOR HP -1A UNIT & CURB
SCALE: NONE
1
� 1.1 •
I
•
13-
fi
HVAC ROOF PLAN
SCAIIF 1/16• - 1' - Or
SCOPE OF WORK
REPLACE 1 DOSING ROOFTOP HEAT PUMP UNIT ELLEN NEB
T
BUILDING OWNER
23215 66111 AVENUE SOUTH
KENT, WA 98032
BUILDING INFORMATION
ZOE: C-U
OCCUPANCY: F2
CONSTRUCTION TYPE: W, SPRINKLER
---0
b
•
LEGAL DESCRIPTION
THAT PORRON OF ME SOUTHEAST QUARTER OF 11E SOUTHEAST QUARTER OF SECTION 26, TOMNSHIP 23 NORMAN, RNIGE 4 EAST.
M.M. N TEE CITY OF 1U(MI/ . KM COUNTY. WASHINGTON 0ESCRIBID AS FOLLOWS
BEGNtNG AT TEE SOUTHEAST CORNER OF SAD SOUREAST QUARTER CF THE 90UDEAST QUARTER
THENCE N 8744 W ALONG DE SOUTH IRE OF SAD SOUDEAST QUARTER OF TIE SOUTHEAST QUARTER A DISTANCE OF 949.49 FEET;
THENCE N 01 E A DISTANCE OF 18&61 FEET TO TIE 1RUE POINT OF BE(NNNINk
THENCE CONTNM N 01'47'29' E A DISTANCE OF 362.16 FEET;
THENCE WONG A CURVE 1O TIE RIGHT IW LNG A RMIUS OF 300.00 FEE. AN ARC DISTANCE CF 90.34 FEEET. THROUGH A CENTER MGM OF
1715'14' TO DE NORTH ME OF SOUTHCENTER IDISIRML 1W81
THENCE S 8812'31' E ALONG SAID NORTH IRE A DISTANCE OF 474.57 FEET TO THE EAST WAGE OF MDOYER PMT( EAST;
THENCE ALONG A CURIE TO TTE LEFT, THE COMER OF WHICH BEARS S 69'09'36' E HAVING A RADIUS OF 330.00 FEET, NN ANC DISTANCE OF
109.71 FEET THROUGH A CENTRAL MK;LE OF 19'02'56' ALONG SAD REST MR
THENCE S 01'47'29' M MONO SAD WEST WRGN A I1STNICE OF 344.01 FEET;
THENCE N 880611' W A DISTANCE OF 470.00 FEET TO DE TRUE POINTOF BE6IMIG.
TAX PARCEL I: 2623049106
n
Permit No.
113% tevle:J Z:77ticti Ts S Tali b NMld6 and oIl okall,
I:poaR c:: ;:,;�.�c'.ion doassents does rot adman
4Hfi appuad +< : ,! �_4 . tea • 401
Nt changes shaa be rt13de to the scep2
Tu! wiles :. :._
NOTE: Revisions will re-i� a�: :. , -'_ __.:..1 :;
an fl may bdude
City of
- .
SEPARATE PERMIT
P. =ti:;Z D FOR:
O tlacF - „aMd
arc25 FUN
_City_of Tukwi"ta_
BUILDING DIVISION I
•
•
I
C8�
1
Ii
L ^J
f ®
CODE CLI 'i?'LTA%CE
C : r f ILA4
COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS
RECORD DRAWINGS OF IC1WL INSTAIAIION SAW. TIE PROVDEO TO 1TE BULO/IG OWNER 1111911 90 DAYS
OF DE LATE OF SYSTEM ACCEPTANCE PER WASH. STATE EHERGEY COOE (MSEC) SECTION 1416.1
AN OPERATION WWUM. AND MANIEIWI E WNW STW.L BE PROVDEO TO THE BINDING OVER PER WSEC
SECTION 14162.
ALL HOC SYSTEMS S1W1. BE BMMICED MD A WORN BM ONCE REPORT SNAIL BE PROVOED TO THE OWNER
PER NEC SECTION 1416.3.
INC CONTROL SYSTEM SIWL BE TESTED; CALMBRATED MD ADA15IED, SEQUENCES OF OPERATION SHALL BE
TESTED TO ENSURE 1}W THEY OPERATE N ACCORD MID SPECIFICATIONS MD APPROVED PLANS, AND COMPLETE
REPORT OF TEST RESULTS SHML BE FTHE'D M TH THE OWNER PER WSW SECTION 1416.4.1. MD 1416.42
}
I BUIL 11f Si} S tti4'I
ABBREVIATIONS
AML
AD.
AP.
AFT.
MI
BF
BOT
CP
CID
CO
CO
CTG
CONC.
CONK.
DEF.
ON
OOB
EA
OIL
EAT
Q
ON
ESP
RR
FE
FPM
FUr
OMEN.
CR.
MI6
INC
it
HP
INS
MAR
ABOVE
ACCESS DOOR
ACCESS PANEL
ABOVE FaNSND FLOOR
MR WIFDLNNG INNT
SEWN FLOOR
BOTTOM
CAST N PUCE
SOLING
COM DIFFUSER
CEILING NN DUE
UM TINNIER GRILLE
CONCRETE
CONNECTION
CUBIC FEET PER MNUTE
COMM
DIAMETER
DUN
ORONO
FaN�
ENTERIC
ENTERING MR TEMPERATURE
ENTERIC WATER TETMPEM11ME
DOWSE
ecIETM STATIC PRESSURE
FLOOR
FOOT or FEET
FEET PER UNITE
FUTURE
GRILLE
HIGH NULL GRNLE
HIGH MAIL TRANSFER GRILLE
HEIGHT
HORSEPOWER
HOT WON SUPPLY
HOT WATER BOURN
D INSIDE ONIETER/JYEIISION
E INVERT ELEVATION
IL WC INCHES M:G.
TIN. CIFF. TEEM DIFFUSER
LRN. FT. MDR FEET/FOOT
LWO LOW WALL GMUE
MI LOW WALL REGISTER
MAX. MADAM
MOH 1000 BRITISH UERI N. UNIS
N OT. DPR. MOTORIZED DAMPER
MID MOUNTED
H.C.
N.O.
OSA
NO
00
PCF
POC
PSI
PSX
MVP
IVA
REQ 0
SQ. Fr.
SA
SL
TON
TO
TOT
T1fP
VTR
MB
MO
W /
W/0
NOMIM LY CLOSED
NORMALLY OPEN
ONSIDE AIR
OPPOSED BADE DAMPER
OUTSIDE aNLETER/IDYENSNON
POUNDS PR NBC FOOT
POINT OF COMMON
POUNDS PER SOWN NCH
POUNDS PER SOME NCH ONCE
REDUCED PRESSURE B :KFU W PRBENTOR
REUEF Mt
REQUIRED
RETUN RR
SQUARE Far
SUPPLY MR
SO= LIED
TOIL MAC FE)D
1RANNER NILE
TOUL
TYPICA.
VENT THROUGH ROOF
MET BNB
TGITER GAGE
DIM
DUCTWORK - LEGEND
0
0
0
0
FEmbi
ATP
4 - 100
S - 100
E - 100
sass
s► -- - - ye SISY
* Fe
-J-. SID
1
a
FD
MO
MR RAW DIRECTION
SUPPLY OR O6A DUCT SECTION UP OR TOWARD
ROUD, RECTA NUM
REARM, RFLEF OR MUST DUCT SECTION UP OR TOWARD
OMR RECTMNGUUR
LY OR E> SECTION DOWN OR AWAY RECNIGUIM
RETURN, Rae OR MUST DUCT SECTION DOWN OR MOW
ROUND, RECUMNIM
ROUND DUCT SYMBOL
RETURN AIt NNW RUNES CFM QlW11NY
SUPPLY Mawr NUMBER BOWES OM QINNITY
MOST AN NUM ER DDICATES ON MAINE(
SOND LIED SLEET METAL
ITEM ETlM:RE NT CONVECTOR
NINE/TIRE DAMPER
FRE DAMPER
1101111E RAWER
MOTORIZED DAMPER
MSG YNES
ROOD TO ROUND 45 F1flING
SQUARE TO SQUARE 4S RUNG
SQUARE TO ROUND 4.7 RING
%9
MN. s 4S FITTING FOR DUE1MON
GENERAL - LEGEND
ICY
° v
It, EQUINE. DUICNORK, NO CRUET
EDSM EQU EIENT. DUCTWORK, MD MIEs
OWL OR OIIUtI11 I TRUER
9EW1 W NER iNOE CUM/b1AGW M SINOWN
SECTION LETTOL
SLEET NUN30R MERE SECRON MORN
REVISIOM CURD & CHNIMUTGIN. NUMBER
BER
DEW REFITIDICE WW
•
NOCENIED
(=YAM rtiravitA
MAR 3 1 4 J. -.,-
ffll.� .J -i ...jf
P E -
s
COPYRIGHT NOTICE
THIS LAYOUT /DESIGN IS AN
UNPUBLISHED WORK, AND
MERIT MECHANICAL HEREBY
RESERVES ITS COMMON LAW
RIGHT, PURSUANT TO TITLE
17 SECTION 2 OF THE USA
CODE TO PREVENT ANY
UNAUTHORIZED COPYING,
PUBLICATION OR USE OF
THIS DESIGN, AND TO OBTAIN
DAMAGES THEREFORE.
Co
co
0
0
■
J
0 .
a
cic
J
0
z
z
t