HomeMy WebLinkAboutPermit M07-067 - BOEING #9-90BOEING #9 -90 9725 EAST MARGINAL WAY S M07 -067 Parcel No.: 0003400018 Address: Suite No: Tenant: Name: Address: doc: IMC -10/06 City.►f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 9725 EAST MARGINAL WY S TUKW Value of Mechanical: 234,800.00 Type of Fire Protection: BOEING #9 -90 9725 EAST MARGINAL WY S , TUKWILA WA Owner: Name: THE BOEING COMPANY Address: PO BOX 3703 M/S #1F-09 , SEATTLE WA Contact Person: Name: JERRY SCOTT Address: PO BOX 47983 , SEATTLE WA Contractor: Name: MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 11 4 0 4 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 510 -7543 Phone: 206 -763 -9400 Expiration Date: 12/31/2008 DESCRIPTION OF WORK: COMPLETE MECHANICAL RENOVATION OF 2 -STORY OFFICE BUILDING. REPLACE (4) AIR HANDLERS WITH CHW & STENUM COILS (SERVED BY PLANT). DUAL DUCT VAV'S, BATHROOM AND MECHANICAL ROOM EXHAUST, CHILLED WATER COMPUTER ROOM AC UNITS, AND STEAM POWERED CONDENSATE PUMPS. DIRECT DIGITAL CONTROLS. M07 -067 05/30/2007 11/26/2007 Fees Collected: $21,889.13 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 4 Diffuser 632 Thermostat 156 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 6 M07 -067 Printed: 05-30 -2007 Permit Center Authorized Signatur I hereby certify that I have read an governing this work will be complie Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or�he performice of work. I am authorized to sign and obtain this mechanical permit. Print Name: 6C/Z4 C .1 e..d 7 Permit Number: M07 -067 Issue Date: 05/30/2007 Permit Expires On: 11/26/2007 Date: permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. Date: S 730 /may This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M07 -067 Printed: 05-30 -2007 City of Tukwila Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #9 -90 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS Permit Number: M07 - 067 Status: ISSUED Applied Date: 04/09/2007 Issue Date: 05/30/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, W, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 M07 -067 Printed: 05-30 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 17: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by art approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (EMC 606.1, 606.2.1) 18: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 21: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (4.4.1.4.2.1)) 22: In areas that are not continuously occupied, automatic smoke detection shall be provided at each fire control unit(s) location to provide notification of fire at that location. (NFPA 72) 23: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #2051) 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M07 -067 Printed: 05-30 -2007 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 5 / - ?(3 7 ° 7 M07 -067 Printed: 05-30 -2007 Company Name: Mailing Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mailing Address: Po r3c ix 4190.3 E -Mail Address: ,errs.. 560 4+154 kvtric 11 Jew, co 44 Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: Company Name: Cr) P . 1v1 At r') r►U u E jC . Mailing Address: /(Q° I F ■fft - k Ave 100 Contact Person: M tc, - e. 56T t, izA E -Mail Address: 44 - 0 4- 4. � . f c s ou,t . CAM Q:\Applications\Fomis- Applications On Line 3 -2006 • Permit Application.doc Revised: 9 - 2006 bh C)TrL City City Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** I SITE LOCATION 7 King Co Assessor's Tax No.: (1003 y0 - —oC l Site Address: 9 / ZS- CA 5'r 1 4 4 fa2 wit- t- l JA- y S Suite Number: Floor: Tenant Name: iSeN e./ o6,,, q' op New Tenant: ❑ Yes Property Owners Name: n 1 -(l_ Bogor.)!„ Cnwtfk kh( Mailing Address: PO 1 3707 lvt/ , 4l I.F -69 L) 4 State State State if?! z4 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: 3Ez KNI Sca.Tr (mAc- otcni4; -P ft•l/U(_S - Day Telephone: (Z° ) S j0 — 7S 56.4 w4 ? y Co City State Zip Fax Number: ( 7 o 4 \ '76 $ L{ Z-S" GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Zip City Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Zip City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record AT WA Be I State Zip Day Telephone: Z 6 7 4 f2) Fax Number: io(o' 622'1— 3775 Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser (032. 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct L i Thermostat is& 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment S Stec .".1 �wered C.A .-w.E& PAN'[ r~olS V Air Handling Unit <10,000 CFM i Incinerator — Comm/Ind Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ....Z Indicate type of mechanical work being installed and the quantity below: Q: Applications\Fotms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh MECHANICAL PERMIT INFORMATION - 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: M aory l}t, D 14 , - # i ! 11.1 r S U 70/0 Mailing Address: Po BOX 147 e3 SEA! �L e._ City State Zip Contact Person: -leg -4 Sccir Day Telephone: (Zo6) S10 - 76 E -Mail Address: j/2-Cfl , SGot"etvt.aUwtt � Cpwl Fax Number: e 4,56,) " Contractor Registration Number: M Ac- DorS 95f0 Expiration Date: / 213 /O-7 1"14- Fuel Type: Electric Gas .... Other: '1.A01" - '( ` ,t(e) (.2>ie✓ 98)46 Valuation of Mechanical work (contractor's bid price): $ 3 $C>c) Scope of Work (please provide detailed information): evwAP1eFe- Met, /GA-) fevt.o "ei ho o two -s+0 o toe bkt 1�4/, Rep 14 at( i )1-i4 cog (4,urve) b plctr,d). ptic,10),A„a VArV15 6.fl,r n ar Wti24.1,c+,v0.0v1 roam 1 2JC NS1 C.LJ(Qf) I.�aTe Go -tpv V foo.� AC wn►TS 4 S eot .A9 -led LG��Sh1 0 70 t.+�_ PItec DIG1 -k\ Ccw o 1 IS, Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTHORIZ Signature: Date: 4 1447 Print Name: ,S!e/C- Mailing Address: F0 Oox 1 17363 Date Application Expires: Lot oi 1 01— Date Application Accepted: M I 01101— Q: Applications\Fonns- Applications On LineU -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: (Zo & S70 — 7S t_ 98 < State Zip Staff Initials: Page 6 of 6 Receipt No.: R07 -00967 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0003400018 Permit Number: M07 -067 Address: 9725 EAST MARGINAL WY S TUICW Status: APPROVED Suite No: Applied Date: 04/09/2007 Applicant: BOEING #9 -90 Issue Date: Initials: JEM Payment Date: 05/30/2007 11:51 AM User ID: 1165 Balance: $0.00 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 1292 17,517.30 Account Code Current Pmts 000/322.100 17,517.30 Total: $17,517.30 Payment Amount: $17,517.30 8712 05/30 9716 TOTAL 17517.30 doc: Receipt -06 Printed: 05-30 -2007 RECEIPT NO: R07 -00535 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www ci. tukwila. wa. us M07 -067 4,371.83 PG07 -090 277.00 TOTAL: 4,648.83 SET RECEIPT Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. Initials: JEM Payment Date: 04/09/2007 User ID: 1165 Total Payment: 4,648.83 SET ID: S000000725 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount Payment Check 1238 4,648.83 TOTAL: 4,648.83 Account Code Current Pmts 000/345.830 4,648.83 TOTAL: 4,648.83 Pro e /A, ' 5-- / 0 Type of In�p` AM l Address: Date Called: Special Instructions: Date Wa ted: �^^-� �Z �aV /(/ f //( .m" p.m. Requester: !!! Phone No: INSPECTION RECORD Retain a copy with permit INSPECTI NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tlz- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I SCI Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 6 ) Pet / ctor: Ins eceipt No.: = �i yP- 5 ;ord , k'63' s,YA/- ) Da - 7 -/ /C t`j Date: /2f712 /f? :00 REINSPECTION FEE EQUIRE . Prior to inspection, fee must be id at 6300 Southcenter vd.. Suite 100. Call the schedule reinspection. 'Date: Project;..., / DE, � 9 � --ca ype of `� s,Nd Kc / f 4) A d ess: _ - 17S n1,>'2G1,1/4-/ Date Called: Special Instructions: mee( r' 6 - /D• i Date W /711417(r--1 a Requester: Phone No: .,z..o 6 -730- z.. s V 0 INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OFD TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. El Corrections required prior to approval. { COMMENTS: Snn 0'4 Ot f}(FF /37 4-1VV 1,5 7. a , iti' t9 /dv, 4 p 2 I QO REINSPECTION F E REQUIRED. Prior to inspection, fee must be pair at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Proje r.: .660 4 - 4'0 Type ol Address: Date Called: Special Instructions: Date Wanted: Requester: Phone No: /7 I2 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 63 00 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 6 El Corrections required prior to approval. 1 COMMENTS: / e e•-q7q.ryk) – go /Ai/ (2-% Pi /9).• .27vP-1(/ — e /A1-7 Date: X? b .00 REINSPECTION FEE R QUIRED rior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: Date: Proiact: _ -- , TO Type of Inspection: ie C / Address: C 7 C Agel///t; Date Called: -i g / Special Instructions: / Date Wanted; / 2 /1211 7 p.m. Requester: Phone No: -2o 4 - /G INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-36 ra Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. El Corrections required prior to approval. COMMENTS: 6 ;26 4 - Date: /2/2 .00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: ;o, ,4 Ad digs 2-5- J) I) ,11.5 : // (3 5 / 5 /3 y �2 F- f / "7/ / /61, / //J /2 -' S I i / /7, r , . / /j - , +-- "l > „27,.0-6/ Requester: =',) 5 2 / / 2 J 7 / 2 / 1 i✓ r /e c v /2 el? / - , - A , /fi,,, ,,„vt., % ) e • , ..-- 1.7/5 6 / 7/ /t /,)/ Project: Type of Inspection: U Ad digs 2-5- Date Called: Special Instructions: Date Wanted: / Requester: Phone No: I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tz (206)431- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. j'; nstztcto paid at 6300 Southcente INSPECTION RECORD Retain a copy with permit IDate: / .00 REINSPECTION P E REQUIRED. Prior to inspection, fee must be Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: late: 1 COMMENTS: )( i?H S. Pcdta( /-eI n,,',/1s kv Y' _ ✓ /sS& 7,0 -('s • Ale!) (9 /Fly' hc, �/`,/ • / lc?, 4 /7 4e. / /9 / Y It (-r6.G.L L,; 5 Lr// /h � / / / (1) /s 1 5 - /3Lev tgt- L /:v-r sFF h , /4L�= h,L4/) /J , ;(1. 7 . fluor oS=All ., ( e a-i-- -- 4Giiv g Date Wanted: �j'''� ,;m- // /� /v / p rrr Requester: Phone D$4 7 s.S 3z..5 j Project: /' / =qe.) Type Qf Inspection: A ess: Date Ca Special Instructions: 1 Date Wanted: �j'''� ,;m- // /� /v / p rrr Requester: Phone D$4 7 s.S 3z..5 j INSPECTION NO. INSPECTION RECORD Retain a copy with permit 17M / PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. 14 Corrections required prior to approval. spec • r: I /fez /k7 .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: Typ of Inspection: A dress:. - 7ZS F / 114 P /AJI9 ( Date Call wL _S Special Instructions: Date Wanted: �a rrf' I i ? 1 3 6 p.m. Requester: Phone No: Qo(- 410 - - 2)Pj0 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IR 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 El Corrections required prior to approval. FF NTS: P } ) sf /= /vv2 S - 6" S0 / ic y % -,%�4 Date: // /75 ) .00 REINSPECTION E REQUIRED. Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: 59MMENTS: / I — ? O 1 ) -'>,(‘') \e).—:1 /0 4 r10,-5 ' w s--4 �'" � '3li S 6 ne- 0,, - NJ &' n a ■■ ct ✓P d(+e lr o OVV Da a Called: Special Instructions: Date Wanted: / � 7 / fill; A -1fi Requester: Phone No: Projec • De I — ? O Type of jr}spection: 41) (c /i — Address: c7? 5 /4 ' 2..1 ) ( Da a Called: Special Instructions: Date Wanted: / � 7 / fill; A -1fi Requester: Phone No: INSPECTION RECORD Retain a copy with permit "7-667 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. (Inspe Dater ( 1 J 0-7 REINSPECTION FEE REQUIRED. Pribr to inspection, fee must be 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: Type o nspection: \j Address: q ?_ E rvv126iivni i...1 Date Called: Special Instructions: Date W(n +( Requester: Phone No' 2 v6 -25 S2 92 INSPICION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION )t- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- proved per applicable codes. El Corrections required prior to approval. COMMENTS: V.3 n (1) 21 a r/ot ._ i > , -{u - - , Date: / $58. R INSPECTION FEE REQUI D. Priori to inspection, fee must be paid t 00 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: p 4 Type f Inspec ion:, Type � — /, Ad ress: 72 5 / n i/ I�2 t e 7 vt, r C i /) ?tr-1 - " / /VS ?/ 69 &Jrt/ --- 0Vm/V - ®4 No % g S 770 %) ,-S r r_ v 7 L - / ,-- C Jii r7 / ..)■• /5 fin/ � vh , 1P ''y�e AZ /77 - 1'/s'7/7 /'y_ ,fr .✓s Pro /...50 F /•v S- 50 Type f Inspec ion:, Type � — /, Ad ress: 72 5 / n i/ I�2 t e 7 Date Called': Special Instructions: Date Wante / Requester: Phone No: e)6 - 5 / /D INSPECTION RECORD I _ � UG Retain a copy with permit rl INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Inspecto l $ .00 REINSPECTION FEE ' EQUIRED. rior to inspection, fee must be Id at 6300 Southcenter Blvd., Suite 1 '0. Call the schedule reinspection. eipt No.: ❑ Corrections required prior to approval. Da : 1Date: L/ COMMENTS s w --I-27_ /5 Tidy/ A ress. /v (it -J /7i,✓ //5 (,)/' P/ D4e _ ; A.. ) 0'.o -,., �e ---- P (t)/ 4 - 1 f a pm — Rd?, i7 %A/ ��� f�f (° Phone No: �° f7 r ) Project: 4362F//K j - 5 D Type of I spection: / 6 , -?/7/ � � ,-' A ress. Date f alled. Special Instructs s: 1 Date WAnted: -- j - 2_ a pm O "2 Requester: Phone No: - f7 r ) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Ei Approved per applicable codes. Corrections required prior to approval. Inspecto .00 REINSPECT(ON FEE R IRED. Prio id at 6300 Southcenter Bt d., uite 100. g eipt No.: ".0 Date7� / z to inspection, fee mus e ll the schedule reins ction. 'Date: /pa 7 -66 Project: (c e0 9 -Ci 0 IS e kV Type qff lnspectiot1 r1vt t � h - /v Address: _ Date Called: Special Instructions: Date Wanted: _ 9 - -cr) co. Requester: Phone No: 2-O(0 — 7 1 - 2330 07-66 INSPECTION RECORD Retain a copy with permit INS CTION NO. PER IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: /9 7� Insp Dat5 - 5 --, 58.00 REINSPECTION FEE REQUIR . Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Sui 100. Call the schedule reinspection. eipt No.: 'Date: Proj G /�, 11.7-?o a Ty of Inspe L ion: a p 70/ 4-0,, /4 - i h i1P1-40 Addr s: 72 s — , , u , 7 Dat ailed: Special Instructions: Date W V nted: .— 0 m. Requester: m go.47/...... 2� ?0 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER fT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: ��� n-r aI-2 ti 1 1a s-1 i/ C.; L,rYe."‘,A.6 / /,G9 /lhi a $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Proje ; Type of Inspection: Address: Date alle•: Special Instructions: / (I Date Wanted: a m. Requester. Phone No: 7' ( 57/-2-33z INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER IT NO. (206)431 -36 Approved per applicable codes. Corrections required prior to approval. COMMENTS: p 4 Get A2 i)-i S v lsr /x( 47,(/ /.r i 7--,; h 4 2 /‘. k 4 / / El $58.00 REINSPECTION F E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: /"r _ // r Z /1/( 7 ` k2 V Mt's/ C/ de X20 y J /rS5 Vi/ — /5 7 ( 041 - 7 41n /n/F.e7 1 1)111-''V Date Wan K 7 -p � r Requester: Phone No: Pro ect: Type of Inspection:, _ Ad ss: CI 7Z5 P16-7 fJ 14 2 c/ Date Called: & r i i Special Instructions: Date Wan K 7 -p a. O. Requester: Phone No: INS P CTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit (206)431 -36 El Approved per applicable codes. El Corrections required prior to approval. EINSPECTION FEE REQ► RED. P • r to inspection. fee must be 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: / / /�v i'r' s / „--L,-- 4 - e -� -�.— - i1i( - 1/49K Address: , 9'715 ��5» /1-2‘ 7�77 .53° /i ,;. Li y 4/e e r'j r i•% _ S/ Special Instructions: Date Wanted: �p.m. 7- .3D -D_ Requester: Phone No: .:7:.c� .57/ -2-3 3 v Project: / t/ - 9 — �v Type of Inspection: b?c.c): h — „i, Address: , 9'715 ��5» /1-2‘ 7�77 Called: e/ Special Instructions: Date Wanted: �p.m. 7- .3D -D_ Requester: Phone No: .:7:.c� .57/ -2-3 3 v ❑ Approved per applicable codes. In pecto $58M REINSPECTION FEE R paid at 6300 Southcenter Blv INSPECTION RECORD Retain a copy with permit CTION NO. CI OF TUKWILA BUILDING DIVISION 630 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 0 Corrections required prior to approval. ! Date: I - 5 J -- 7 C4 A4/ QUIREt Prior to inspection, fee must be Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pro t Type of Inspection�j - /A.) Address: q 72 ?a/ /1// ;? 4/1) D e Called: _ Special Instructions: Date Wanted: 7- //'- U- a.m. p.m Requester: Ph neN : 6 - s 7/ - 233 0 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. /11G 06 7 (206)431 -36 Corrections required prior to approval. COMMENTS: a 9- ( 2 ) f ' I ?'-- suir 2— P er Date REINSPECTION FEE REQ RED. Pri to inspection, fee must be at 6300 Southcenter Blvd., uite 100. lithe schedule reinspection. (Receipt No.: 'Date: spector Pro eect: Type of. spectign: Address: r 7Z5 f' /7S/ 41„,� „v4 Date Called: ` Special Instructions: Date Wanted: 7 /3-07 p Requester: Phone No 206. — 57/ —Z35O INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: n ` 614.fe //. .S a m /ova r� I D")- (3 `J .00 REINSPECTION FE EQUIR D. Prior to inspection, fee must be T- id at 6300 Southcenter Eli .. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Pro' ct: Type of I pection: - Address: 9 ? ghl Date Called: Special Instructions: Date Wanted: -�- /d.-07 a m . Requester: Phone N gone _S7/ -2 330 FJ INSPECTION RECORD Retain a copy with permit /790 7'� 1 NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: / 2, Ne-c/ (Receipt No.: t t Date: 2—to $ :.00 REINSPECTION FE- REQUIRED 1Pnor to inspection. fee must be id at 6300 Southcenter vd.. Suite O. Call the schedule reinspection. 'Date: Project: 4Fiit/6 / - - - c/() Type of Inspection: / /)/-. /A /A/ Address:. C 7,7 .5 _ / J,J,2riit f-) / Date Called: Special Instructions: Date Wanted: 6", - / 7 C/ 7 m. p.m. Requester: Phone No: NSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. 0. 6)431 - 3670 Corrections required prior to approval. COMMENTS: f,..) / % vuYc-- .00 REINSPECTION FE REQUIRE . Prior to inspection, fee must be paid at 6300 Southcenter lvd.. Suite 00. Call the schedule reinspection. (Receipt No.: 'Date: April 17, 2007 Ken Nelsen City of Tukwila Department of Community Delvelopment 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Subject: Permit Application M07 -067 Dear Ken: I received your letter regarding the incomplete application of permit M07 -067 in which you requested energy code compliance forms be included for the HVAC equipment. As we subsequently discussed, existing central plant utilities are used for all cooling and heating loads in the form of chilled water and steam. As a result, no new cooling or heating is added in association with this project. Furthermore, all new air handling equipment installed is controlled via a centralized DDC system and utilizes the required economizer controls and dead bands. It is my understanding that in light of the above information, the energy code compliance forms will not be required. Please let me know if there is any further information or clarification you need in processing this permit. Sincerely, Jerry Scott Project Manager MacDonald - Miller FACILITY SOLUTIONS RECEIVED CrrY Oc TUKWtLA APR 17 2007 PER ..' • INCOMPLETE LTR# _k_ P.O. Box 47983 7717 Detroit Avenue SW 206.763.9400 MacDonald - Miller Facility Solutions, Inc. Seattle, WA 98146 Seattle, WA 98106 www.macmiller.com PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -067 DATE: 04 -17 -07 PROJECT NAME: BOEING #9 -90 SITE ADDRESS: 9725 EAST MARGINAL WY S Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 5 ,U 1 Bull Ing ivision Vi 14: Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete LJ Comments: Documents/routing slip.doc 2 -28-02 REVIEWER'S INITIALS: PERMIT COORD COPY Fire Prevention Structural Incomplete ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator DUE DATE: 04-19-07 DATE: Not Applicable C n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route [ Structural Review Required ❑ No further Review Required DATE: C DUE DATE: 05-1 7-07 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ■ ACTIVITY NUMBER: M07 - 067 PROJECT NAME: BOEING #9 -90 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # DATE: 04 -09 -07 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: , B ding�ivision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: V V LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: bhila TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documentshouting slip.doc 2 -28 -02 PERMIT COORD COPY `- PLAN REVIEW /ROUTING SLIP PPG t Fire Prevention Nj Structural Incomplete Approved with Conditions ❑ Permit Coordinator LI DUE DATE: 04-10-07 Not Applicable n No further Review Required DATE: Planning Division n DUE DATE: 05-08-07 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # Project Name: Project Address: y /i7 /o Entered in Permits Plus on City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Boeing #9 -90 9725 East Marginal Wy S Contact Person: Jerry Scott Summary of Revision: Pe-,r --1 e -.Q / ,.ode P h / ) (' I ' C,& (GU L r t c kic , C l( / "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: M07 -067 Phone Number: ('o() 76 –/-125 rz.b.Aa coKvu s4fi o w t i& /6_„. it2� /5cti 4 ,1 -1.7 s 66 ,, it NI I rG�uG� / � /5 Pfa✓i�� % 1i /s v. Sheet Number(s): t'l0 1 /` pt 54) p‘,0 - f7-49kiw ( cofL' Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED ClTlt Of TtJKwtl,A APR 17 2097 PF.R)jr 0 ^F?4 TF.Fk License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company Previous License DIVCOI *988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SIGMUND, FREDRIC PRESIDENT 12/31/2002 KOPET, TYLER SECRETARY 12/31/2002 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MACDOFS980RU 05/30/2007 SYM 99 VICI\ 11' MAP 7 -127 KING COUNTY AIRPORT OFFICE CENTER (FAA) 99 FROM SEATTLE -- TACOMA AIRPORT FROM DOWNTOWN SEATTLE co EAST MARGINAL. WAY CORPORATE PARK DEVELOPMENTAL CEO BOH 599 TUKWILA TER 900 EXT 157 DUI 158 FROM KENT & AUBURN EXIT NO SCALE G URIC J 157 900 v AREA NAP BUILDING ADDRESS: 9725 EAST vARGIVAL WAY SOUTH TUKWILA, WASHINGTON 98108 9 -90 BUILDING LOCATION NO SCALE REVISION TARP AHCAH �C BUILD! BY G 9 -90 RE\OVATIO\ (VOLUV JOB #150589-01 BOEI\G DEVELCPVE\TAL CENTER G725 E. MARGINAL WAY S. L<WILA, WASHI\CT0.\ 98108 APPROVED DATE GENERAL NOTES DEMOLITION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING DEMOLITION. DO NOT PROCEED WITH DEMOLITION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO GARY TALLER AT BUILDING 9-51.2 COLUMN N /1, AFTER COMPLETION OF WORK OF THIS CONTRACT. PROJECT CHECKLIST CHECK BOX ® THESE DRAWINGS CONFORM TO THE I.B.C., I.F.C., I.M.C., U.P.C., N.E.C. AND THE WAC 51--20 AS ADOPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA, WASHINGTON ZONING. ❑ ROOMS LABELED PER OCCUPANCY PER I.B.C. TABLE 1004.1.2. ® BUILDING FLOOR NUMBER ON PRINT. FOR AREA OF CONSTRUCTION. ® NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS ® 2. TENANT IMPROVEMENT (NON— STRUCTURAL): ❑ 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. MECHANICAL, 4 COMPLETE SETS. ❑ 4. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: SELECTIVE DEMOLITION OF BOTH FLOORS OF THE 9-90 BUILDING, WITH REMOVAL OF MOST INTERIOR WALLS, TOILET ROOMS, CEILINGS, FLOOR COVERINGS, EXTERIOR GLAZING SYSTEMS, MECHANICAL HVAC & PLUMBING SYSTEMS AND ELECTRICAL POWER & LIGHTING THROUGHOUT. PROJECT ALSO INCLUDES INSTALLATION OF NEW WALLS, CEILINGS AND FLOOR COVERING THROUGHOUT. INSTALLATION OF NEW EXTERIOR WINDOW AND ENTRY SYSTEMS AND NEW MECHANICAL HVAC & PLUMBING SYSTEMS AND ELECTRICAL POWER AND LIGHTING SYSTEMS TO SUPPORT THE NEW LAYOUT. £WLNW° 5185 C ITE T S OTT KRUSE STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY v SS L- SYST E OF 2) DEPT. DATE DRAWN DER GROUP CHECKED ENGINEER CHEKED APPROVED APPROVED SUBTITLE TITLE 004.04unainno v #vjLv�1 ' TITLE SHEET - VOLUME 2 9 -90 RENOVATION BUILDING 9 -90 ARCHITECTURAL MASTER COL. VS CODE SU VlN ARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR PENTHOUSE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC CATEGORY: DESIGN LOADS: ROOF — SNOW ROOF — LIVE FLOOR — OFFICE (LIVE) FLOOR' — DEAD FLOOR — MECHANICAL & STORAGE FLOOR --- STAIRS AND CORRIDORS WIND LOADING BY Date: Plan review approval Is subject to errors and omissions. Approval of construction documents does not authori:e the violation of any aaepted code or ordinance. Receipt of approved F,t Id Co an condit'on�s Is cknovrledgetl: _. , CitY of Tukwila CITY OF TUKWILA, WASHINGTON * 2003 * 2003 * 2003 * 2005 * 2005 * 2005 INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL FIRE CODE (IFC) INTERNATIONAL MECHANICAL CODE (IMC) NATIONAL ELECTRICAL CODE (NEC) UNIFORM PLUMBING CODE (UPC) STATE OF WASHINGTON ENERGY CODE * STATE OF WASHINGTON BARRIER FREE CODE WITH ICC A117.1 * CITY OF TUKWILA, WA. AMENDMENTS GROUP B, OFFICE TYPE II —B, NON—COMBUSTIBLE 67,351 145,382 67,351 67,351 10,680 44 FT. 2 NO CHANGES „ 25 PSF 20 PSF 150 PSF 20 PSF (PARTITION) 125 PSF 150 PSF 80 MPH, EXPOSURE C LIA E CODE CO APPROVED MAX 24 2001 C I Of Tukwila BUILDING DIVI .TON BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT f.:7 '." !'ATE PERMIT FOR: E ld`'ical : 'Jlumbing G als Piping City of Tukwila BUILDING DIVISION RevisTilpos No changes shall be made to tho sc e Cl c:c-Cz Without prior oppro Pal c7 Cuii ng r: quire a now plan submittal :....1 i.:, ...;:� additional plan review fcs. ISSUE FOR PER V IT DATE DEV. CENTER, WA on DLR Group CURRENT REVISION SHEEP JOB NO. DWG NO. Architecture Engineering Planning Interiors MtI-AN IcAL. GO SYMBOL R I G 150680 --01 09-090—GO RECEIVE) CITY OF TUKkArILA APR 0 9 2007 PERMIT is 11T'i 4 11Eg DATE COMP NO. 04.05.07 INCLUDED IN SET NO, SHEET NO. DRAWING SUBTITLE REV DATE DRAWING • 9- 90 -2M260 2M260 SECOND FLOOR FIRE SPRINKLER PLAN ORIG 04.05.07 • 9- 90 -2M261 2M261 SECOND FLOOR FIRE SPRINKLER PLAN ORIG 04.05.07 • 9- 90 -2M262 2M262 SECOND FLOOR FIRE SPRINKLER PLAN ORIG 04.05.07 • 9- 90 -2M263 2M263 SECOND FLOOR FIRE SPRINKLER PLAN ORIG 04.05.07 9- -90 -E0 E0 LIGHTING FIXTURE SCHEDULE ORIG 04.05.07 • 9- 90- UGM450 UGM450 ENLARGED UNDERGROUND DRAINAGE PLANS ORIG 04.05.07 • 9- 90 -1M450 1M450 ENLARGED TOILET ROOM DOMESTIC WATER PLANS ORIG 04.05.07 • 9- 90 -1M451 1M451 ENLARGED TOILET ROOM DRAINAGE PLANS ORIG 04.05.07 • 9- 90 -1M452 1M452 ENLARGED MECHANICAL ROOM PLANS ORIG 04.05.07 • 9-- 90 -2M450 2M450 ENLARGED TOILET ROOM DOMESTIC WATER PLANS ORIG 04.05.07 • 9- 90- -2M451 2M451 ENLARGED TOILET ROOM DRAINAGE PLANS ORIG 04.05.07 • 9- 90- P1M450 . P1M450 ENLARGED WEST PENTHOUSE HVAC PLAN ORIG 04.05.07 • 9- 90- P1M451 PAM451 ENLARGED EAST PENTHOUSE HVAC PLAN ORIG 04.05,07 • 9- 90- P1M452 P1M452 ENLARGED WEST PENTHOUSE PLUMBING PLAN ORIG 04.05.07 • 9- 90- P1M453 P1M453 ENLARGED EAST PENTHOUSE PLUMBING PLAN OR1G 04.05.07 • 9- 90- P1M454 P1M454 ENLARGED WEST PENTHOUSE FIRE SPRINKLER PLAN ORIG 04.05.07 • 9- 90- P1M455 P1M455 _ ENLARGED EAST PENTHOUSE FIRE SPRINKLER PLAN ORIG 04.05.07 • 9- 90 --RFM3 RFM3 COMPOSITE ROOF MECHANICAL PLAN ORIG 04.05.07 • • 9- 90 -M310 M310 CONTROLS DIAGRAM ORIG 04.05.07 • 9- 90 -M311 M311 SEQUENCE OF OPERATION ORIG 04.05.07 • 9- 90 -M312 M312 STEAM SYSTEM DIAGRAM ORIG 04.05.07 • 9- 90 -M313 M313 PLUMBING DIAGRAM ORIG 04.05.07 • 9- 90 -M314 M314 PLUMBING DIAGRAM ORIG 04.05.07 • 9-90-M315 M315 COMPRESSED AIR AND FIRE SPRINKLER DIAGRAMS ORIG 04.05.07 9- 90 -1E63 1E63 FIRST FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 • • 9- 90 -M500 M500 PENTHOUSE SECTIONS ORIG 04.05 07 • 9-90-M501 M501 SECTIONS ORIG 04.05.07 • 9- 90 -M502 M502 DETAILS ORIG 04.05.07 • 9- 90 -M503 M503 DETAILS ORIG 04.05.07 • 9- 90 -M504 M504 SEISMIC BRACING DETAILS • ORIG 04.05.07 • 9- 90 -M505 M505 HVAC DETAILS ORIG 04.05.07 • 9-- 90 -M506 M506 HVAC DETAILS ORIG 04.05.07 • 9- 90 -M507 M507 PLUMBING DETAILS ORIG 04.05.07 • 9- 90 -M508 M508 PIPING DETAILS ORIG 04.05.07 • 9-90-M509 M509 STEAM SYSTEM DETAILS ORIG 04.05.07 • 9- 90 -M510 M510 AIR HANDLING UNIT DETAILS ORIG 04.05.07 • 9- 90 -M510A M51OA AIR HANDLING UNIT DETAILS ORIG 04.05.07 9- 90 -1E360 1E360 FIRST FLOOR TELECOMMUNICATIONS PLAN ELECTRICAL 04.05.07 • 1/ 9- 90 -2E2R 2E2R COMPOSITE 15kV FEEDER REMOVAL PLAN ORIG 04.05.07 9- 90 -1E362 1E362 FIRST FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • P 9 -90 -1 E7R 1E7R CABLE TRAY ROUTING REMOVAL PLAN ORIG 04.05.07 2 9 90 -2E7R 2E7R CABLE TRAY ROUTING REMOVAL PLAN ORIG 04.05.07 9- 90 --2E60 2E60 SECOND FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 • H 9- 90 -1E1OR 1E1OR FIRST FLOOR LIGHTING REMOVAL PLAN ORIG 04.05.07 9-90-2E62 9 90 -1 E11 R 1 E11 R FIRST FLOOR LIGHTING REMOVAL PLAN ORIG 04.05.07 9- 90 -2E63 9 90 -1 E12R 1E12R FIRST FLOOR LIGHTING REMOVAL PLAN ORIG 04.05.07 H4 9-- 90 -1E13R 1E13R FIRST FLOOR LIGHTING REMOVAL PLAN ORIG 04.05.07 9-90-2E110 2E110 SECOND FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 • 1 H 9- 90 -2E1OR 2E1OR SECOND FLOOR LIGHTING REMOVAL PLAN ORIG 04.05.07 9-- 90 -2E11R 2E11R SECOND FLOOR LIGHTING REMOVAL PLAN ORIG 04.05.07 • 9- 90 -2E12R 2E12R SECOND FLOOR LIGHTING REMOVAL PLAN ORIG 04.05.07 )A 9- 90 -2E13R 2E13R SECOND FLOOR LIGHTING REMOVAL PLAN ORIG 04.05.07 • 9- 90 -2E260 2E260 SECOND FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9- 90 -3E1OR 3E1OR WEST PENTHOUSE LIGHTING REMOVAL PLAN ORIG 04.05.07 • 9- 90 -3E11R 3E11R EAST PENTHOUSE LIGHTING REMOVAL PLAN ORIG 04.05.07 • 9- 90 -2E263 2E263 SECOND FLOOR FIRE ALARM PLAN ORIG 04.05.07 a 9- 90 -1E6OR 1E6OR 208Y/120 VOLT POWER REMOVAL PLAN ORIG 04.05.07 • 9 -90 -1 E61 R 1 E61 R 208Y/120 VOLT POWER REMOVAL PLAN ORIG 04.05.07 • 9 90 -1 E62R 1E62R 208Y/120 VOLT POWER REMOVAL PLAN ORIG 04.05.07 H 9 --90 -1 E63R 1E63R 208Y/120 VOLT POWER REMOVAL PLAN ORIG 04.05.07 • 9- 90 -2E363 2E363 SECOND FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 H 9-- 90 -2E60R 2E60R 208Y/120 VOLT POWER REMOVAL PLAN ORIG 04.05.07 • 9- 90 -2E61 R 2E61R 208Y/120 VOLT POWER REMOVAL PLAN ORIG 04.05.07 9 -90 -2E62R 2E62R 208Y/120 VOLT POWER REMOVAL PLAN ORIG 04.05.07 64 9 -90 -2E63R 2E63R 208Y/120 VOLT POWER REMOVAL PLAN ORIG 04.05,07 a 9- 90 -3E60R 3E60R WEST PENTHOUSE POWER REMOVAL PLAN ORIG 04.05.07 1 9- 90 -3E61 R 3E61R EAST PENTHOUSE POWER REMOVAL PLAN ORIG 04.05.07 i P 9 -90 -1 E111 R 1 E111 R 480Y/277 VOLT POWER REMOVAL PLAN ORIG 04.05.07 El 9- 90-- 1E112R 1E112R 480Y/277 VOLT POWER REMOVAL PLAN ORIG 04.05.07 i ri 9- 90- 2E112R 2E112R 480Y/277 VOLT POWER REMOVAL PLAN ORIG 04.05.07 JVH 2 INCLUDED IN SET NO. SHEET NO. DRAWING SUBTITLE REV DATE DRAWING 9-90-E4AR E4AR WEST PENTHOUSE ONE -LINE REMOVAL DIAGRAM _ ORIG 04.05.07 4 9- 90 --E4R E4R EAST PENTHOUSE ONE-LINE REMOVAL DIAGRAM ORIG 04.05.07 • 9- -90 -E0 E0 LIGHTING FIXTURE SCHEDULE ORIG 04.05.07 • 9-90-1E7 1E7 FIRST FLOOR COMPOSITE CABLE TRAY PLAN ORIG 04.05.07 • 9- 90 -2E7 2E7 SECOND FLOOR COMPOSITE CABLE TRAY PLAN ORIG 04.05.07 • 9- 90 -1E10 1E10 FIRST FLOOR LIGHTING PLAN ORIG 04.05.07 • 9-90-1E11 1E11 FIRST FLOOR LIGHTING PLAN ORIG 04.05.07 • 9-90-1E12 1E12 FIRST FLOOR LIGHTING PLAN ORIG 04.05.07 • 9-90-1E13 1E13 FIRST FLOOR LIGHTING PLAN ORIG 04.05.07 • 9- 90 -2E10 2E10 SECOND FLOOR LIGHTING PLAN ORIG 04.05,07 • 9-90-2E11 2E11 SECOND FLOOR LIGHTING PLAN ORIG 04.05.07 • 9- 90 -2E12 2E12 SECOND FLOOR LIGHTING PLAN ORIG 04.05.07 • 9- 90 -2E13 2E13 SECOND FLOOR LIGHTING PLAN ORIG 04.05.07 • 9- 90 -3E10 3E10 WEST PENTHOUSE LIGHTING PLAN ORIG 04.05.07 • 9-90-3E11 3E11 EAST PENTHOUSE LIGHTING PLAN ORIG 04.05.07 • 9-90-1E60 1E60 FIRST FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 • 9- 90 -1E61 1E61 FIRST FLOOR 208Y/.120V POWER PLAN ORIG 04.05.07 • 9-90-1E62 1E62 FIRST FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 • 9- 90 -1E63 1E63 FIRST FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 • 9 -90 -1 E64 1E64 ENLARGED FIRST FLOOR 208Y/120V POWER PLAN OR1G 04.05.07 • 9-90-1E110 1E110 FIRST FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 • 9-90-1E111 1E111 FIRST FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 • 9-90-1E112 1E112 FIRST FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 • 9-90-1E113 1E113 FIRST FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 • 9-90-1E260 1E260 FIRST FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9-90-1E261 1E261 FIRST FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9- 90 -1E262 1E262 FIRST FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9-90-1E263 1E263 FIRST FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9- 90 -1E360 1E360 FIRST FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • 9- 90 -1E361 1E361 FIRST FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • 9- 90 -1E362 1E362 FIRST FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • 9-90-1E363 1E363 FIRST FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • 9- 90 --2E60 2E60 SECOND FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 • 9- 90 -2E61 2E61 SECOND FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 • 9-90-2E62 2E62 SECOND FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 • 9- 90 -2E63 2E63 SECOND FLOOR 208Y/120V POWER PLAN ORIG 04.05.07 _ • 9-90-2E110 2E110 SECOND FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 • 9- 90 -2E111 2E111 SECOND FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 • 9-90-2E112 2E112 SECOND FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 • 9- 90 -2E113 - 2E113 SECOND FLOOR 480Y/277V POWER PLAN ORIG 04.05.07 ^ • 9- 90 -2E260 2E260 SECOND FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9- 90 -2E261 2E261 SECOND FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9- 90 -2E262 2E262 SECOND FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9- 90 -2E263 2E263 SECOND FLOOR FIRE ALARM PLAN ORIG 04.05.07 • 9-90-2E360 2E360 SECOND FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • 9-- 90- -2E361 _ 2E361 SECOND FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • 9- 90 -2E362 2E362 _ SECOND FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • 9- 90 -2E363 2E363 SECOND FLOOR TELECOMMUNICATIONS PLAN ORIG 04.05.07 • 9-- 90 --3E60 3E60 PENTHOUSE POWER PLAN ORIG 04.05.07 • 9- 90 -3E260 . 3E260 PENTHOUSE FIRE ALARM PLAN ORIG 04.05.07 • 9 -90 -E4 E4 ONE -LINE DIAG. - SUBSTATION NO. 51 -EAST PENT. ORIG 04,05.07 • 9- 90 -E4A E4A ONE -LINE D1AG.- SUBSTATION NO. 25 -WEST PENT. ORIG 04.05.07 • 9 -90 -E8 E8 OUTDOOR LIGHTING PLAN ORIG 04.05.07 • 9-90-2E2 _ 2E2 COMPOSITE 15kV FEEDER PLAN (FOR REF. ONLY) ORIG 04.05.07 9 -90 -UGM3R 9--90 -1M3R 9 -90 -1M4R 9 -90 -1M13R 9-90 -1M6OR 9 -90 -1M61R 9-90 -1M62R 9 -90 -1M63R 9 -90 -2M3R 9 -90 -2M4R 9-90 -2M1OR 9 -90 -2M11R 9 -90 -2M12R 9-90 -2M13R 9 -90 -2M60R 9 -90 -2M61R 9-90 -2M62R 9 -90 -2M63R 9-90-P1M3R 9- 90 -P1M4R 9 -90 -P1 M450R 9- 90- P1M451R 9-90-RFM3R 9- 90--MO 9 -90 -M1 9-90-M2A 9 -90 -M2B 9-90-M2C 9-90 -1M110 9-90 -1M111 9-90 -1M112 9 -90 -1M113 9 -90 -2M110 9 -90 -2M111 9 -90 -2M112 9-90 -2M113 9-90 -1M12 9 -90 -1M13 9 -90 -2M10 9 -90 -2M11 9 -90 -2M12 9-90 -2M13 9 -90 -1M60 9 -90 -1M61 9 -90 -1M62 9-90 -1M63 UGM3R 1M3R 1M4R 1M6OR 1M61R 1M62R 1M63R 2M4R 2M1OR 2M11R 2M12R 2M13R 2M60R 2M61R 2M62R 2M63R P1M3R P1M4R P1M450R P1M451R RFM3R MO M1 M2A M2B M2C 1M110 1M111 1M112 1M113 2M10 2M11 2M12 2M13 1M60 1M61 1M62 1M63 2M61 2M62 2M63 1M260 1M261 1M262 COMPOSITE UNDERGROUND PLUMBING REMOVAL PLAN FIRST FLOOR PLUMBING REMOVAL PLAN FIRST FLOOR FIRE SPRINKLER REMOVAL PLAN FIRST FLOOR DUCTWORK REMOVAL PLAN FIRST FLOOR DUCTWORK REMOVAL PLAN FIRST FLOOR DUCTWORK REMOVAL PLAN FIRST FLOOR DUCTWORK REMOVAL PLAN FIRST FLOOR HVAC PIPING REMOVAL PLAN FIRST FLOOR HVAC PIPING REMOVAL PLAN FIRST FLOOR HVAC PIPING REMOVAL PLAN FIRST FLOOR HVAC PIPING REMOVAL PLAN SECOND FLOOR PLUMBING REMOVAL PLAN SECOND FLOOR FIRE SPRINKLER REMOVAL PLAN SECOND FLOOR DUCTWORK REMOVAL PLAN SECOND FLOOR DUCTWORK REMOVAL PLAN SECOND FLOOR DUCTWORK REMOVAL PLAN SECOND FLOOR DUCTWORK REMOVAL PLAN SECOND FLOOR HVAC PIPING REMOVAL; PLAN SECOND FLOOR HVAC PIPING REMOVAL PLAN SECOND FLOOR HVAC PIPING REMOVAL. PLAN SECOND FLOOR HVAC PIPING REMOVAL PLAN PENTHOUSE PLUMBING REMOVAL PLANS PENTHOUSE FIRE SPRINKLER REMOVAL PLANS ENLARGED WEST PENTHOUSE HVAC REMOVAL PLAN ENLARGED EAST PENTHOUSE HVAC REMOVAL PLAN COMPOSITE ROOF MECHANICAL REMOVAL PLAN COORDINATION FIRST FLOOR PLAN COORDINATION SECOND FLOOR PLAN MECHANICAL SCHEDULES MECHANICAL SCHEDULES MECHANICAL SCHEDULES COMPOSITE UNDERGROUND PLUMBING PLAN FIRST FLOOR PLUMBING PLAN FIRST FLOOR PLUMBING PLAN I FIRST FLOOR PLUMBING PLAN ' FIRST FLOOR PLUMBING PLAN SECOND FLOOR PLUMBING PLAN SECOND FLOOR PLUMBING PLAN 1 SECOND FLOOR PLUMBING PLAN I SECOND FLOOR PLUMBING PLAN ' . FIRST FLOOR DUCTWORK PLAN FIRST FLOOR DUCTWORK PLAN I , FIRST FLOOR DUCTWORK PLAN FIRST FLOOR DUCTWORK PLAN SECOND FLOOR DUCTWORK PLAN SECOND FLOOR DUCTWORK PLAN SECOND FLOOR DUCTWORK PLAN SECOND FLOOR DUCTWORK PLAN FIRST FLOOR HVAC PIPING PLAN FIRST FLOOR HVAC PIPING PLAN FIRST FLOOR HVAC PIPING PLAN FIRST FLOOR HVAC PIPING PLAN SECOND FLOOR HVAC PIPING PLAN SECOND FLOOR HVAC PIPING PLAN SECOND FLOOR HVAC PIPING PLAN SECOND FLOOR HVAC PIPING PLAN FIRST FLOOR FIRE SPRINKLER PLAN ORIG ORIG ORIG BRIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG OR1G ORIG ORIG ORIG ORIG ORI G ORIG ORIG ORIG OR1G ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG ORIG 04.05.07 04.05.07 04.05.07 04.05.07 04.05, 07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05,07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05,07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 04.05.07 ORIG 04.05.07 ORIG 04.05.07 INCLUDED' IN SET \DI- X 0 DRAWING NO. SHEET NO. DRAWING SUBTITLE REV DATE • 9- 90 -1M263 1M263 FIRST FLOOR FIRE SPRINKLER PLAN ; ORIG 04.05.07 DRAW CS VOL ORIG 9 -90 RENOVATION J #150680 -01 MEM REVISION BY APPROVED DATE SYM DLR GROUP DR /LS 04.05.07 REVISION BY APPROVED DATE 5188 REGISTERED ARCHITECT ASHINGTON CURRENT REVISION J #150680 -01 SHEET G3 SY 'ORIG 7FIvdI;° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION I APPRO' APPROVED BY DRAWN DATE SUBTME DLR GROUP 11.15.06 CHECKED ARCHITECTURAL MASTER INDEX OF DRAWINGS - VOLUME 2 9 -90 RENOVATION BUILDING MO ISSUE FOR PERMIT DEV. CENTER, WA JOB NO. DWG NO. PREL ORIG A ISSUE LEGEND NOT YET ISSUED PREVIOUSLY ISSUED FOR CONSTRUCTION PREVIOUSLY ISSUED, BUT NOT IN THIS ISSUE INCLUDED iN THIS ISSUE REVIEW CODE COMP APPROVE 140 24 7011 City Of Tu�uiia . ILO N DMSIo� B PRELIMINARY ISSUE FOR REVIEW OR INFORMATION ONLY NOT FOR CONSTRUCTION ORIGINAL ISSUE FOR PERMIT, BID, PROCUREMENT OR CONSTRUCTION DRAWING REVISION - SEE SPECIFIC DRAWING FOR NATURE OF REVISION Architecture Engineering ENGINEER CHECKED APPROVED APPROVED 150680 -01 09- 090 -G3 Ci T'1 RECEIVED 'APR 0 9 2007 PEI ; 4:,, DLR G rou p DATE Planning COMP NO. 04.05.07 Interiors M. SOTURA 9 -90 RENOVATION REVISION J#150680 -01 M. SOTURA 04.05.07 ACCEPTABILITY C0 w N THIS DESIGN AND /OR 1 SPECIFICATION IS APPROVED DATE 1 15.07 01.15.07 COORDINATION FIRST FLOOR PLAN 9 -90 RENOVATION BUILDING 9 -90.1 MECHANICAL MASTER COL. A- Y/1 -13 CURRENT REVISION JOB NO. 150680 -01 9- 90--M0 DATE 04.05.07 COMP NO. N � l lll■i� �I■�W Triple moarium E - � g �.r..rrrl. �;oL aw :1J�11� =n�� —� �� i ■. I - 1111111151 �= �! IIf111[JI111I 111111: it III .III M Ii_ = , `11 J T ■ ° I r�r l�* .� firfi_.91 111 La ' .�I1.� L IAAl�I !• i 1 I •11�h ; � = - - - , L�9I" _.� I�.I�I�I fi " IIIIa�II 111104. +IIIIll F IIIIFI i 1 ►' � 1 ` : I: 1I� � ii I - p p [ II111111IIII 11IIIllll lt111 11IIIIIIIIIIiIlIIll llil # II1lAllliii . 1 111 1 111111 1 I 11111 IIII1111IIIi11111 '.lIdIIIIIAII iy7..;• - �' l 1 11Ex r 71 !1�' ; 11 .. ,..— _�.,w,..t�_rrdl iinc ■ nig �� .���� � l .hL .. ... If111111111IIIf .• I11111I111111 111 I111,!!�'_� E � � i � I� _ w_rr� r�r.. �,.,. ;__ = .w...i■ • -. -.--- sir �. rrrrr_ �r �W ; 511i1� 1l ilf 1111[ Iillllr ?�ri 1111 11 11111 11 1[ 111111111i11111I1I11I11 1 :Itilllllllllll ■ — - -�� -- .�. EILILICZT _ r . �aI i- I-- a_y a lrr.rra ___ ■a �__ wr - : 1 ... ... r rt_ lurr�.rr..t Ir1� V ... d 11 - . - !!!I 11 1111 ' l � II 11 II r11�_��J� .� �..1 ■ = . J1 1111 , �■ 1�1R1� i s t� ��—* w1 1• N[I.II r�rc_rlw.l_.�.rrrrrrrr_ l7# ....� -I ��_ rrrrn� � ...�= ■t.1 . ..� >lw ;;: rr>........t r�`>A :'1.==+1 .rrt!�! 11_: " 1 ;l; EiI :: �� ' �`" "1 �MIII II , alai I 1111. /.i III�� 11111III11IIfI111I1III11111111IIGI1f11IIIIIII1 [IIII N I I 1 1 iii �1►�1 ��r.. � � , �.. , : , � 11.1111° � y w�cr�r� Iii■' — "` Q r ``I1111 '"���i 1 0 11 l .� I —Ell I o �_1,- 1111 I � �`. ■IIErI� > 1 r i i 1111■I1,, Irrrr_. - -- - - r�"..r� ..rr_.rl � .! =I■rrlr_1w�1w_ -11� � � daw =1111.1111 V it till :?31r l i 11; : '11 I.� IL:II:Z. . � [�m, m.l■1� - n11I111I11n�1feu1111111 IIl�lr [rlfu1 _ — • • T �> F � 1 ii111112 I [ �111� I : ...._ �, - iii. I.rrtill. ! i � ! :!1i 5 ` I RR ^IiIij �I ° - l . 1%. ``t• 11I�.�- �A��1•�A�� . r III1! ill lll [111IIIE111IIIIIIIIIIIfilllllf[ 4t11111 111! IIiIJ!I!I1f1[IIIf11i1111iflini 11E1 111.-1111100 fl��t 1T;Y„7 1 mfflimmini • - ; -n - �1111[I ' !i Iii�Illl]'",," I 11 ,• : __ i N "71f111I11IIflI111Il1r. 71111 IIIIIIIIII111111111111 [IIIII1111f11Ii111111I111 -; 1 ;:Ltrw� Ail ill 1� ■■ li�l II 11=1•1. v :1_ 0 4I I llI111[JIIIIf1I11 11111111 1111IIIuii[[[IIIII 7..011 II » I� Il -,= i 11■..NllsI.i' A 1i A � � = 1 �. j P., _!_n L1 ..■>: - :11' = ' .i■� �>E ■ )VIII 1!�311i>ttlra L:II� 11 .1� : 11111 II�ii 11 aI�•�,�II�IJ Its- a al � 11 � I � IIII �� iI1 �� 1 'I � � 311 ..._ 1E1 MO Ili rJJ, _ I WOW, . inimmin • 0 r -�I� �����i ' j moral -� ►, �■ :iVi. �■l '~ - �. COORDINATION FIRST FLOOR PLAN SCALE: 1 /I6"= 1' -0' 0 ISSUE FOR PERMIT qIFMAN I N E E K S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 O O O D 4 0 1M3 ® KEY PLAN SCALE: NONE RECEIVED errs OF TUKW . LA APR 0 9 2001 PERMIT CENTER 16' 8' 0 8' 16' 32' SCALE: 1/1 6"=1'-0" SYM ORIG 9 -90 RENOVATION REVISION wlr - .w � � lt I i ____ �� I II AInMx11l 1 :: r l Z� ~. ---+.. "0'=� ::° r a= ■ lll m ■I■Il� I nn !iu i11 = l i � f mil i �~-J ■rrl■rlrrr •, a lam• i.fa: -� -•- I illll1111 ". ItllllflulY 1 1 I �.� N Ilt 1 ItAl111IF11 i Irl = 14 IIII ! IIIlIIIl1111111M ItlillllYllEAl1 11111111111:IIAlIIIlIAII IlulullllMlt�.:: "Ilrtil lull! u 111111II11t11111.: 9111Y11lIIIIII111AIi111YAlI1MN11Illtrl _ __� _ _ - IEIIi1lYllllt11E111111 ' /A1YEUI11111Y11it Kii - —� - -I: l .c1 a'.�i,! !,1 :. •,� I I VIII �...- - .rrl.,I ,I illi as I i j11i_ _ -I i- ■. -• LT G l∎ •wl-a..` �I a.waaa1.. -ww:. r =1 == IOW ti I.__I di 6 ilidi ......_,... - ra • I � IIIII Iris •l -� i ii I .��:.�. gi - � .` � -_ w alIIIIIIIIIIIIIIIII IIIIIluImlltnnununlnitu 1 II III ME MIMI= 8111Inw limn II IIIIIIIIIIIIIHIIIIIIIIIIIIIIIIIIIIIIMIIIIII% ••=. - 1.11=Pla 2 11E1 LIP .. 11 III 1- - il 1 ii il LEN. Fir, iii ... .. . ,-.earminuni lil'': I 111 F �.■r.a —.!MIN —� 1 !�� �s�■— ■■■■■■! — — --rte - ! /�41111[ � �� . 1�. ■� kij1 it I I E 1 ����= � ■�� 111111 IIEIIIIIIIIIlINI 1 1IIi11u111I1111a Il Ill I11I111111 1 I II1I1111111111IIJiIIitll lllr I X111 : _ `` I • `,- -��i = ■ I E ,11111I1 i Ii 11 zll. �I�� �r !I I_���■ 11!.,11 ■■ _ r . Iworrr= aaw- itmori I�If.1r #M.�.�IK. i :n _ -- � I ..._� I� ■ • �I� •a.r— ■w— r.r�r_:,lal -wl: i MIN Ull gl 11111111■ IrIt11AI1r1ElUA11111lIIIIIrl1AIlElY111111�� - c .5 ���� L; — ••r*- .. rr�.. — r� �s,�lr 1i�1■■I11♦ ■ I ' ■■.,y■..,.r.r_•�....wn o II NI' ;11- AINIII xI IA - I i1 .I,. r�r- w■.n - I . I_,..... 1E 1_ : a>•rl s_, r�( I o I �>,:�a ' X11 itwtililisiml ■,. IR 11 I 111lIF IIIIIIAltIFIlIllutlllll l it nl■.rr_I i t urn ■1 1 �� r I�I lEIIIUI IF I1-.il� a 1 � I Ir 1 IIL]!iL�11! 1•IPI� ■El■ _ .wl■�. II I 4( it111111i11N11IEU111111III11II111IIlIUh III111111IIIIrIt1II1111111ifIIu Iiiii1Illlll11I11_. 91IINII11l11II1111111i ittt'.:I lllllilllllllE!a 1111111 ;IIELIAIYEIUIrl11Y ______1t 11111%:.',! tllFllllllrllilllllllltl [IIIEllillll111111iiif 1 I1 fEllllllllllllllululllllrlllllllillll rl I IlIl1111111IIr1111r11111111I11111E .i _ _ —7 1111111110 : Ji rr�w1(o - '°' s} art • ..sx+..— ..:.rr .:.,_,....1.��.►� -„�, ■wr...R��w�■■1� al! � ■ w r■r.l -.a � � ;�..rr— >r rrrrr r rrae -= rta MECUM MENU! • - , rte- `..� stop i S ['.�rTi�l���� ■r �r.www�.�■■ —■zxi� . ii,�l� 111lflliilllC? IltII1lE1111111 II IIIIIIIIIIII riu r IIIlI 11 t 1 I 11 I 1 Il 11 IIlllItIMM 111 MI71trAlllEllrll 111! L; 1111tM11111l llrlllll11111l 1l lllYll ttlill k+- ��_'iEAEM111i1It111tiIlII111AAI _____ ___ = • 1,—mom s # r■�ri�rit.r�a�w�r:Ini:F#■�■�•. 1 � allra '�Ilrr■t�c.Ir■■r+lrrfrl■t - - - : iIii ■raw - .1 ■=�1ll��ll1 I�ill■ liil 1I■I••r °. � JHIIIr • 1 ��.- —�. M. 1•131111a/ MUM Il . �1 IIIII11I11i1111uIIIIIII1111111111HIIIIIEIIIr1111111 ■ ' iiiitlIII11IIflll'1 AIIIIIIEEIIIIIINIIIIi:; II _ !__�_ MI __ � r +CIS - t_ I( - -- - I _ _ 4111;IN111111111111ir i' iitln 111111IkillVil1Yi11ki111111 1I� r1111A1hII II111II1ii11�kll 741•11111111111 'MOM Ili it - 111 • I ii': IltutAAl !llllttlt llrItI111111IYllll11 I111l11III1tail II11111111111 _111 ir 111°""!51111 IN �utarrl ,16--11 ? NI 1 � �« w � �I ,!.~ate � ,,,.■��`. 0 � 111 ,11 `I `III > f 111141.11111 I �""r`>.rs ; � j a rrrrnrrw.�� i ..1I�: 1 1 iLi E L _ i 1 _ 1 • � 44150680 -01 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 REVISION COORDINATIO SCALE: 1/16 "= 1'-0 BY APPROVED DATE V SECOND FLOOR PLAN ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. ISSUE FOR PERMIT DATE COFFMAN CHECKEb M. SOTURA ENGINEER CHECKED APPROVED APPROVED DA I.,D7 01.15.07 SUS MECHANICAL MASTER AcOFFMAN NGINEIRS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 - 1625 206 623 0717 Fax 206 624 3775 COORDINATION SECOND FLOOR PLAN 9 -90 RENOVATION BUILDING 9 =90.2 COL A-- Y/1 --13 BE1I. CENTFR_WA SHEET DWG NO. &. L\.\.k KEY PLAN SCALE: NONE 16' 8' 0 8' 16' 32' SCALE: 1/16 =1' -0" CURRENT REVISION M 1 JOB NO. 150680 -01 '"" O —on .IAI DATE RECEIVED an Off Tl1K'NtLA APR 0 9 2007 PERMIT CE,i I �• COMP NO. 04.05.07 SCHEDULE Qt MARK CFM ESP TSP (IN) (IN) 2 S Sl s & 30,000 3.3 6 SUPPLY FANS TYPE RPM VFD PLENUM 1067 YES MOTOR HP 2© 50 BRAKE FIR 43 AIR HANDLING UNIT AREA SERVED EAST SIDE EAST SIDE WEST SIDE WEST SIDE MARK CC--1 1 2 1 5-2 S--3A & S3B S -4 35,000 30,000 2.9 3.3 35,000 2.9 5 6 5 PLENUM PLENUM 899 1067 YES YES PLENUM 899 YES 50 2@ 50 50 42.25 43 CC -2 42.25 -- * LEAVING AIR TEMPERATURE SHALL BE 54F AFTER SUPPLY FAN. * * STEAM COIL SHALL BE SIZED FOR 20,000 CFM FROM 25F TO 60F AND WITH A MAXIMUM PRESSURE DROP OF 0.2" AT 60,000 CFM. CFM 60,000 60,000 D 80 'F 80'F ENT AIR B WB 63`F LVG AIR* DB WB 52'F 51T 63'F 52T 51'F CO APD (IN) MAX 0.6 0.6 OLING COILS GPM 316 316 CHILLED WATER ENT LVG ROWS 42'F 54'F 6 42'F 54'F 6 • PRESS. DROP 10 FT 10 FT NOTE 1: TOTAL ELECTRICAL LOADS: AHU -1 & AHU -3: MCA= 146.25, MOCP =200 NOTE 2: FOR AHU -1 & AHU -3: MINIMUM OUTSIDE AIR IS 20,000 CFM COIL SIZE MARK CFM ENT 4 @ 54"x 83" 4 @ 54 "x 83" HC- 1 HC -2 HC -3 20,000 (60,000) 35,000 20,000 (60,000) AIR 25' F 60'F 25'F LVG ** APD AIR (IN) MAX 60'F 95'F 60' F 0.2 0.15 0.2 HEATING COILS MBH 756 1323 756 HC -4 35,000 60'F 95'F 0.15 1323 AHU -2 & AHU -4: MCA= 81.25, MOCP=125 STEAM ROWS PRESS. LBS /HR DROP 787 1378 787 1378 1 1 1 1 0.3 FT 0.3 FT 0.3 FT COIL SIZE 2 @ 48"x120" 2 @ 45 "x106" 2 @ 48 "x120" 0.3 FT 2 @45 "x106" MIN OUTSIDE AIR (CFM) 20,000 0 20,000 0 EFF PRE FILTERS SIZE 30 30 30 30 2 "x24x24 2 "x24x24 2 "x24x24 FINAL FILTERS EFF SIZE 85 85 85 2 "x24x24 85 12 "x24x24 12 "x24x24 12 "x24x24 12 "x24x24 BASIS OF DESIGN TEMTROL TEMTROL TEMTROL REMARKS DATE OF SERVICE COLD DECK HOT DECK COLD DECK TEMTROL HOT DECK SYSTEM AHU -1 AHU-2 AHU -3 AHU -4 RETURN FANS (EXISTING) SYSTEM AHU -1 &2 AHU -1 &2 AHU -3 &4 AHU -3 &4 AREA SERVED EAST SIDE EAST SIDE WEST SIDE WEST SIDE MARK R -13 R-14 R -11 R -12 CFM 28,000 28,000 28,000 28,000 S.P. " H2O 5/8" 5/8" 5 / 8 " 5 / 8 " OUTLET VEL WHELL DIA 40" 40" 40" 40" WIDTH DWDI DWDI DWDI DWDI CLASS 1488 1488 1488 1488 RPM 420 420 420 420 BRAKE HP 4 4 4 4 MOTOR* HP 10 10 10 10 VOLTS 460 460 460 460 PH HZ 3 3 3 3 60 60 60 60 VFD ** YES YES YES YES BASIS OF DESIGN AMERICAN STANDARD IND DIVISION, DETROIT SIZE 402 DATE OF SERVICE *: KEEP 10 HP MOTOR, CHANGE SHEAVES SO MAXIMUM FAN SPEED IS 420 RPM WHEN MOTOR SPEED IS MAXIMUM. * *: ELECTRICAL CONTRACTOR TO PROVIDE NEW VFD WITH BYPASS EXHAUST FAN (EF) SCHEDULE MARK NUMBER EF-- -1 DRIVE SIDE RGHT EF -2 EF-3 EF -4 LOCATION WEST PENTHOUSE EAST PENTHOUSE WEST PENTHOUSE ROOF AREA SERVED (ROOM NO.) WEST BATHROOMS EAST BATHROOMS MECH RM 12J6 MECH RM 11V6 FAN DIA SIZE 18 18 ARRNGMT. NUMBER 9 9 CLASS CFM 5,000 4,450 1000 900 TOTAL STATIC PRESS. INCHES WG 0.75 0.75 0.75 0.75 APPROX. RPM 1296 1197 1356 1542 RIGHT INLET GUIDE VANES NO NO NO NO BHP 1.09 0.90 0.25 0.21 MOTOR HP 1--1/2 1 1/3 1/3 VOLTS 460 460 460 460 PH 3 3 3 3 HZ 60 60 60 60 WEIGHT LBS 260 260 95 50 BASIS OF DESIGN GREENHECK MODEL QEI- 18-- -I GREENHECK MODEL QEI-- 1 8 -I GREENHECK MODEL BSQ- 120-3 GREENHECK MODEL GB -101 -3 DATE OF SERVICE PRESSURE POWERED CONDENSATE PUMP PACKAGES MARK CPP -1A CPP-1B CPP --PA LOCATION MECH RM 11V6 MECH RM 12J6 WEST PENTHOUSE CPP -PC CPP -PD EAST PENTHOUSE EAST PENTHOUSE CPP -PB WEST PENTHOUSE SERVICE BUILDING STEAM BUILDING STEAM HC -3 STEAM COIL HC -4 STEAM COIL HC -1 STEAM COIL HC -2 STEAM COIL CONDENSATE TEMP 'F 212 212 212 212 212 212 RECEIVER STORAGE CAPACITY GALS 12 65 1.6 1.6 1.6 1.6 SIZE 10 "DIAx36" 20 "DIAx48" 6 "DIAx12" 6 "DIAx 12" 6 "DIAx 1 2" 6 "DIAx12" CAPACITY LBS /HR 2,800 14,000 1500 1000 MAX HEAD PSIG 20 30 10 10 10 10 MOTIVE STEAM PRESS PSI 60 60 15 15 15 15 SPIRAX SARCO PUMP TWO 1" PPEC TWO 3 "X2" PTC PIVOTROL APT -14 APT -14 BASIS OF DESIGN SPIRAX SARCO SPIRAX SARCO SPIRAX SARCO SPIRAX SARCO 1500 1000 APT -14 APT -14 SPIRAX SARCO SPIRAX SARCO DATE OF SERVICE NOTE: CPP -1A & CPP -1 B SHALL BE PROVIDED IN TWO SPLITS IN ORDER TO BE INSTALLED IN MECHANICAL ROOMS STEAM PRESSURE REDUCING VALVE SCHEDULE PRV - WEST PENTHOUSE MARK I LOCATION PRV -2 I WEST PENTHOUSE PRV ---3 I MECH ROOM 11V6 CAPACITY (LBS /HR) 1300 3900 50 VALVE SIZE (IN) 3/4 1 -1/2 1/2 INLET PRESS (PSI) 125 125 125 DISCH PRESS (PSI) 15 15 60 STRAINER SIZE (IN) 1 -1/2 3 3/4 BASIS OF DESIGN SPIRAX SARCO 25P (PILOT OPER) 25P (PILOT OPER) 25MP (DIRECT OPER) DATE OF SERVICE NOTE: PROVIDE STEAM SEPARATOR FOR EACH PRV REVISION 9 -90 RENOVATION J#150680 -01 BY COFFMAN APPROVED M.SOTURA DATE 04.05.07 YYM REVISION BY APPROVED DATE Q�BOE /NG° o- STEAM TRAP SCHEDULE MARK STP K9 ST2P8 ST2E6 ST1V6 STPG5 STPH8 STPH6 STPR8 STPR6 ST1V6 ST1J6 STPR8 STP R6 STPGB STPH6 STPJ9 LOCATION WEST PENTHOUSE SECOND FLOOR SECOND FLOOR MECH 11V6 WEST PENTHOUSE WEST PENTHOUSE WEST PENTHOUSE EAST PENTHOUSE EAST PENTHOUSE MECH 11V6 MECH 11J6 EAST PENTHOUSE EAST PENTHOUSE WEST PENTHOUSE WEST PENTHOUSE WEST PENTHOUSE SERVICE PRV -1 6" STEAM LINE 6" STEAM LINE PRV-2 WH P1 STEAM COIL STEAM COIL STEAM COIL STEAM COIL CPP -1A CPP -1B CPP -PD CPP -PC CPP-PD CPP -PC STEAM METER CAPACITY (LBS /HR) 250 250 250 60 90 150 150 150 150 150 SIZE 3/4 3/4 3/4 3/4 3/4 1/2 1/2 1/2 1/2 1 1 3/4" 3/4" 3/4" 3/4" 3/4" INLET PRESS (PSI) 125 125 15 15 15 15 15 60 60 15 15 15 15 15 DISCH PRESS (PSI) 20 20 20 20 5 5 5 5 5 5 5 STRAINER SIZE (IN) 3/4" 3/4" 3/4" 3/4" 3/4" 1/2 1/2 1/2 1/2 1 1 3/4" 3/4" 3/4" 3/4" BASIS OF DESIGN SPIRAX SARCO TD52 TD52 TD52 FT 150 TD52L TD52L TD52L TD52L TD52L TD52L TYPE OF TRAP THERMO DYNAMIC THERMO DYNAMIC THERMO DYNAMIC THERMO DYNAMIC FLOAT THERIv10 DYNAMIC THERMO DYNAMIC THERMO DYNAMIC THERMO DYNAMIC THERMO DYNAMIC THERMO DYNAMIC FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC FLOAT & THERMOSTATIC DATE OF SERVICE ACCEPTABILITY THIS DESIGN ANWOR SPECIFICATION IS APPROVED APPROVED BY DRAWN COFFMAN CHECKED M.SOTURA ENGINEER DEPT. ISSUE FOR PERMIT DATE APPROVED DATE SUBTITLE AFOFFMAN NGINEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 MECHANICAL SCHEDULES TITLE MECHANICAL MASTER 9-90 RENOVATION BUILDING 9-90 DEV. CENTER,WA CODE. COWL0CE. APPRO CURRENT REVISION SHEET DWG NO. M2A JOB NO. COMP NO. APR 0 9 2007 PERMIT Cat I JI • ■ tf COMPUTER ROOM COOLING UNIT (AC) SCHEDULE MARK NUMBER LOCATION (ROOM NUMBER) MAKE CONNECTION (INCHES) MODEL NOMINAL CAPACITY TONS FAN FAN MOTOR COIL COOLING CAPACITY VENT CHILLED WATER AIR FILTER ELECTRICAL REMARKS TYPE & DEPTH EFFICIENCY PE 5 RA E MAX S G VOL PHASE FLA WSA MFCB DRIVE TYPE CAPACITY (CFM) ESP IN WG KOHLER KINGSTON K -4330 CAPACITY 1000 BTU /HR ROOM TEMP ('F) FLOW GPM EMT 'F MAX PD © MAX FLOW FT H2O HP SENSIBLE TOTAL DB AC1 K8 DCN RM 11J7 LIEBERT MINI-MATE2 KOHLER BARDON K-4960 ET MMD92C 5 DIRECT 2500 0.5 1.5 59,000' 67,100 75 10 45 7.6 2 30% - 208 3 2.8 3.5 15 FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, LIQUI -TECT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, SMOKE DETECTOR, DISCONNECT AC1K7 ELEV EQ 13J6 LIEBERT MINI -MATE2 DEDICATED TRANSFORMER MMD23C 1.5 DIRECT 750 0.3 0.2 14,900 15,700 75 3.1 45 4.2 2 30% - 208 3 1.4 1.8 15 FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, LIQUI-TECT 410 POINT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, DISCONNECT AC1 E10 SoSAC SERVER LIEBERT SYSTEM 3 ELKAY EROM28RAC FH302C 15 BELT 9,300 0.35 (2) 5 185,200 206,200 75 45.0 45 11.9 4 60% - 208 3 98.8 123.5 125 (2) 5 HP FAN MOTORS, 2 WAY VALVE, 28.9 CV, DOWN FLOW MODEL WITH 12 "HIGH SEISMIC ZONE 4 FLOOR STAND W/ BRACING FOR CONTRACTOR PROVIDED TURNING VANES, FACTORY RETURN PLENUM W /GRILLE, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 81.0 MBH, LIQUI -TECT WATER DETECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1 E9 SoSAC SERVER LIEBERT "XD" SYSTEM KOHLER WHITBY 6710 W /GUARD XDP 46 -- - - - 546,080 -- - 140 45 41 - - - 208 3 4.0 -- - SPLIT SYSTEM, CONDENSATE DETECTION, XD PIPING SYSTEM & VALVES AC1 E9a SoSAC SERVER LIEBERT "XD" SYSTEM SEE PLAN FOR SIZE (2) XDO 5.7 - - - -- - _ _ _ _ _ _ _ -- 120 1 2.7 ea. -- - EXTERNAL MOUNTING BRACKET, (3) BYPASS FLOW CONTROL VALVES, CONDENSATE DETECTION, (5 FUTURE) AC1 F10 SoSAS SERVER LIEBERT SYSTEM 3 FH302C 15 BELT 9,300 0.35 (2) 5 185,200 206,200 75 45.0 45 11.9 4 60% - 208 3 98.8 123.5 125 (2) 5 HP FAN MOTORS, 2 WAY VALVE, 28.9 CV, DOWN FLOW MODEL WITH 12 "HIGH SEISMIC ZONE 4 FLOOR STAND WI BRACING FOR CONTRACTOR PROVIDED TURNING VANES, FACTORY RETURN PLENUM W /GRILLE, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 81.0 MBH, LIQUI -TECT WATER DEFECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1F9 SoSAS SERVER LIEBERT "XD" SYSTEM XDP 46 - - - - 546,080 - - 140 45 41 - - - 208 3 4.0 - - SPLIT SYSTEM, CONDENSATE DETECTION, XD PIPING SYSTEM & VALVES AC1F9a SoSAS SERVER LIEBERT "XD" SYSTEM (5) XDO 5.7 - - -- - - - - - -r - - - - 120 1 2.7 ea. - - EXTERNAL MOUNTING BRACKET, (2) BYPASS FLOW CONTROL VALVES, CONDENSATE DETECTION, (3 FUTURE) AC1H7 SoSAU SERVERS LIEBERT SYSTEM 3 UH248C 12.5 BELT 5,900 0.3 3 149,700 190,000 75 37.6 45 19.1 4 60% - 208 3 65.5 81.9 90 (1) 3 HP FAN MOTOR, 2 WAY VALVE, 28.9 CV, UP-FLOW MODEL WITH FACTORY DISCHARGE PLENUM, CONDENSATE PUMP, INFRARED HUMIDIFIER, ELECTRIC HEAT 58.8 MBH, LIQUI -TECT WATER DETECTION, HIGH EFFICIENCY FILTERS, SMOKE DETECTOR, DISCONNECT AC1 D12 SoSAC BLUE TEAM LIEBERT DATAMATE DME044C --PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 - -- 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC1E12 SoSAC BLUE TEAM LIEBERT DATAMATE DME044C --PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 -- -- 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC1F12 SoSAC RED TEAM LIEBERT DATAMATE DME044C -PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 - -- 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC1K9 SoSAC BLUE TEAM LIEBERT DATAMATE DME044C --PC 3 DIRECT 1320 0.3 .27 24800 26900 75 7.5 45 10.4 2 - - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC1 K10 SoSAC RED TEAM LIEBERT DATAMATE DME044C ---PC 3 DIRECT 1320 0.3 427 24800 26900 75 7.5 45 10.4 2 - - 208 1 2.2 2.8 15 2 WAY VALVE, CONDENSATE PUMP, LIQUI -TECT WATER DETECTION SENSOR AC2J7 DNC RM 21J6 LIEBERT MINI -MATE2 MMD40C 3 DIRECT 1250 0.3 0.5 27305 30085 75 6 45 5.7 2 30% -- 208 3 2.8 3.5 15 FACTORY FILTER BOX, FILTER CLOG SWITCH, 2 WAY VALVE, CONDENSATE PUMP, AUXILIARY DRAIN PAN, LIQUI -TECT LEAK DETECTION SENSOR WITH A 6' LONG WIRE TO UNIT, DISCONNECT PLUMBING FIXTURE SCHEDULE MARK NUMBER MARK NUMBER DESCRIPTION CONNECTION (INCHES) CAPACITY TYPE REMARKS BASIS OF DESIGN SAN VENT HW CW REMARKS FIXTURE FAUCET /FLUSH VALVE (MIXING VALVE) SPOUT OR ACCESSORY DRAIN TYPE P -1 WATER CLOSET 4 2 - 1 -1/4 WALL-HUNG VOLTS KOHLER KINGSTON K -4330 SLOAN OPTIMA ROYAL NO 111 ES SEAT: OLSONITE 95SSC PUP1 G5A P -2 URINAL 2 -1/2 - 3/4 115 WALL -HUNG FLUSH VALVE (H) HANDICAP KOHLER BARDON K-4960 ET SLOAN SP-- 5186- 10.ES -S -BOE W /EL 518 A -BOE - DIRECT P-3 LAVATORY 1--1 /2 1 -1 /2 1/2 1/2 BELL & GOSSETf SERIES 60 COUNTERTOP ELEC. SENSOR (120V TO COMMON TRANSFORMER) KOHLER INVITATION - K- 2098. . SLOAN ETF -600 TRANSFORMER ELF- 154(ONE PER 3 LAVATORIES) WATER . P -4 LAVATORY -1/2 -1/2 1/2 1/2 -- WALL HUNG DEDICATED TRANSFORMER KOHLER CHESAPEAKE . K-� 1728 (4"CENTERS) SLOAN ETF -600 TRANSFORMER ELF -154 115 1 P -5 SHOWER 2 1 -1 /2 1 /2 1 /2 GELCOAT STALL W/ GRAB BARS &SEAT SET STALL, ON FULL BED GROUT STALL: LASCO 1603 BFSC COLOR. . BONE CHICAGO 17621 S BRASS BODY W/ STAINLESS STEEL GRID P -6 ELECTRIC WATER COOLER 1.1/2 1 -1/2 -- 1/2, WALL HUNG PROVIDE WATER FILTER 4.5 AMP AT 120V-1 PH ELKAY EROM28RAC FILTER: EVERPURE 9 -1/2" H54 SERIES W /QL -3 HEAD P -7 SINK 2 1 -1 /2 1 /2 1 /2 SINGLE COMPARTMENT COUNTERTOP, STAINLESS STEEL UNDER MOUNTED -REFER TO ARCM. FOR COUNTER DETAILS ELKAY ELU -1616 CHICAGO 201 AHA -8 GRID P-8 SERVICE SINK 3 2 1/2 1/2 FLOOR MOUNTED KOHLER WHITBY 6710 W /GUARD CHICAGO 956R-369 FD -1 FLOOR DRAIN VARIES VARIES -- - 1 /2 "TRAP PRIMER (SAN ONLY) SEE PLAN FOR SIZE SMITH 2010 -B STRAINER:SQUARE NICKLE - BRONZE FD-2 FLOOR DRAIN VARIES VARIES - -- 1 /2"TRAP PRIMER SEE PLAN FOR SIZE SMITH 2630 FFD -1 FLOOR DRAIN VARIES VARIES - - 1/2"TRAP PRIMER SEE PLAN FOR SIZE SMITH 3510 -F19 PUMP (PU) SCHEDULE MARK NUMBER SERVICE FLUID TEMP 'F CAPACITY SIZE (IN) CONSTRUCTION PERFORMANCE MOTOR PUMP TYPE BASIS OF DESIGN SERVICE DATE REMARKS GPM TDH SUCT CW DISCH BODY FITTINGS EF NPFHR DRIVE TYPE HP VOLTS PH HZ RPM PUP1 G5A DOMESTIC HOT WATER RECIRC WATER 120 5.0 • 25 1 115 1 BRONZE BRONZE 50 - DIRECT 0.25 115 1 60 1750 INLINE BELL & GOSSETf SERIES 60 START/STOP AS PROGRAMMED BY BUILDING DDC SYSTEM PUUGW6A SUMP PUMP WATER - 35 15 - 1 -1/4 - -- - - --- 0.33 115 1 60 1800 SUBMERSIBLE PACO ASA SELF CONTAINED START /STOP SEMI- INSTANTANEOUS WATER HEATER SCHEDULE TAG SERVES LOCATION MWP (PSIG) CAPACITY (GPM) INLET TEMP 'F OUTLET TEMP 'F CONNECT ONS (IN.) STEAM COND. PSIG UNIT POWER REQUIREMENTS UNIT WEIGHT FULL (LBS) BASIS OF DESIGN SERVICE DATE REMARKS CW HW LB /HR PSIG VOLTS PHASE AMPS WHP1G5A DOMESTIC PENTHOUSE 150 (0300'F 18 40 120 1.25 1.25 720 15 2 115 1 2 PATTERSON-KELLY PK 06D DOUBLE WALL HEAT EXCHANGER PROVIDE W/ F &T TRAP. ASME (SECTION 8) VESSEL BACKFLOW PREVENTER SCHEDULE MARK NUMBER SERVICE DEVICE SIZE (INCHES) TYPE CAPACITY BASIS OF DESIGN GPM PD (PSI) BF1 D71A DOMESTIC WATER SERVICE 3 REDUCED PRESSURE 200 13 WILKINS 37T BF1 D71B DOMESTIC WATER SERVICE 1 -1/2 REDUCED PRESSURE 100 15 WILKINS 975 BF1 V61A IRRIGATION WATER 2-1/2 . DOUBLE CHECK 100 6 WILKINS 350 PROV APPROVED 01.15.07 DWG NO. 9 -90 -M2B MFCB - MAXIMUM FUSE OR CIRCUIT BREAKER WSA -- WIRE SIZING AMPS FLA -- FULL LOAD AMPS APPROVED DATE SYM 04.05.07 REVISION BY APPROVED DATE BOE /NQ° mums 1/10/09 ACCEPTABILITY DRAWN THIS DESIGN AND /OR C' SDTURA SPECIFICATION IS APPROVED 1. APPROVED BY DEPT. DATE ISSUE FOR PERMIT C'EC ED DATE SUBTITLE 01.15.07 TITLE N FFMAN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 MECHANICAL SCHEDULES 9 -90 RENOVATION BUILDING 9 -90 MECHANICAL MASTER DEV. CENTER WA CURRENT REVISION SHEET JOB NO. M2B 150680-01 sn 'ORIG , °FTw r APR 0 9 2007 PERWIT CE :N ah DATE COMP NO. 04.05.07 DIFFUSER AND GRILLE SCHEDULE MARK 24x24 SQUARE CEILING DIFFUSER CD1 CD2 CD3 CD4 CD5 CD6 CD7 CD9 CD10 CD11 CD12 CD13 SG1 SG2 RG7 RG8 RG9 RG12 RG13 RG14 EG1 EG2 EG3 EG5 EG6 EG7 EG 12 TG 1 TG2 TYPE 24x24 SQUARE CEILING DIFFUSER 24x24 SQUARE CEILING DIFFUSER 24x24 SQUARE CEILING DIFFUSER 24x24 SQUARE CEILING DIFFUSER LINEAR SLOT CEILING DIFFUSER LINEAR SLOT CEILING DIFFUSER ROUND DIFFUSER 12x12 SQ CEILING DIFFUSER 24x24 SQ CEILING DIFFUSER LINEAR SLOT DIFFUSER HIGH WALL SUPPLY GRILLE HIGH WALL SUPPLY GRILLE CEILING RETURN GRILLE CEILING RETURN GRILLE CEILING RETURN GRILLE SIDE WALL RETURN GRILLE SIDE WALL RETURN GRILLE SIDE WALL RETURN GRILLE CEILING EXHAUST GRILLE CEILING EXHAUST GRILLE CEILING EXHAUST GRILLE CEILING EXHAUST GRILLE CEILING EXHAUST GRILLE CEILING EXHAUST GRILLE HIGH WALL EXHAUST GRILLE HIGH WALL TRANSFER GRILLE HIGH WALL TRANSFER GRILLE NECK SIZE 60 80 100 120 140 100 120 80 ROUND DIFFUSER 100 80 100 80 SEE PLANS SEE PLANS 22x10 22x16 22x22 18x16 14x18 36x28 8x8 1Ox10 12x12 24x4 22x6 NC 25 22x10 25 SEE PLANS 25 25 SEE PLANS 25 SEE PLANS 25 25 25 25 25 25 25 25 25 25 25 25 33 29 33 25 25 25 25 MAXIMUM DUCT CONNECTION SIZE DESIGN CFM ROUND SQUARE 25 100 60 25 25 210 80 380 100 600 120 25 750 140 25 235 100 280 100 210 80 380 100 210 80 380 100 250 100 SEE PLANS SEE PLANS 450 1100 1650 1250 750 2500 200 80 350 100 500 120 300 100 450 700 SEE PLANS SEE PLANS SEE PLANS 22x6 22x10 22x12 22x10 22x8 34x22 8x6 12x6 14x8 10x6 14x6 22x6 BASIS OF DESIGN TITUS TMS TITUS TMS TITUS TMS TITUS TMS TITUS TMS TITUS TBDI -30 TITUS TBDI -30 TITUS TMRA TITUS TMRA TITUS TMS TITUS TMS TITUS FLOW BAR TITUS 300RL TITUS 300RL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 35ORL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 350RL TITUS 350ZRL REMARKS LAY —IN CELING LAY —IN CELING LAY —IN CELING LAY —IN CELING LAY —IN CELING 4' -0" LONG (3) 1" SLOTS 4' -0" LONG (3) 1" SLOTS SURFACE MOUNT SURFACE MOUNT 4'—O" LONG (1) 1.5" SLOT WITH OPPOSED BLADE DAMPER "0" DEGREE DEFLECTION 1. REFER TO FLOOR PLANS FOR SIZES OF WALL AND DUCT — MOUNTED GRIL AND REGISTERS, 2. DIFFUSERS SHALL NOT EXCEED NOISE CRITERIA (NC) PER THE SPECIFIED BASIS OF DESIGN MANUFACTURER'S TESTING STANDARDS, EXCEPT IN MECH RMS., ELEC RMS., & ELEV EQUIP RMS. 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION OF DIFFUSERS AND GRILLES WITH OTHER CEILING ELEMENTS. CONTRACTOR SHALL VERIFY CEILING TYPES IN ALL AREAS AND CONFIRM BORDER STYLES PRIOR TO ORDERING GRILLES, REGISTERS AND DIFFUSERS. I EXPIRES 1/10/09 ACCEPTABILITY THIS DESIGN AND /OR PECIFICA11ON IS APPROVED APPROVED BY DRAWN COFFMAN CHECKED M.SOTURA ENG INEER APPROVED APPROVED DATE 1 15.07 01.15.07 DEPT. MECHANICAL MASTER MECHANICAL SCHEDULES 9 -90 RENOVATION BUILDING 9-90 DEV. CENTER,WA CURRENT REVISION sYMBOL DATE 04.05.07 9 RENOVATION 4150680 --01 COFFMAN M.SOTURA _ 04.05.07 REVISION APPROVED DATE SYM REVISION BY APPROVED DUAL DUCT TERMINAL UNIT SCHEDULE MARK A B C D E F G COLD DUCT TYPICAL SETPOINT RANGE COLD DECK(BOX) COLD DUCT LOWEST MIN. HIGHEST MAX. INLET SIZE _ BRANCH SIZE _ 50 80 150 210 325 450 580 170 340 700 1000 1500 2100 2600 4 6 8 10 12 14 16 6 8 10 12 14 16 18 HOT DUCT MAXIMUM HOT DUCT HOT DUCT CFM (PER PLANS) INLET SIZE SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 OUTLET DUCT SIZE 8x8 10x8 12x12 14x12 18x14 22x16 24x18 SOUND POWER 2 4 6 53 64 74 74 77 75 77 47 59 67 66 66 64 66 38 51 55 53 55 56 56 ADDITIONAL SOUND ATTENUATION NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED REMARKS DESIGN BASED ON NAILOR MODEL 3230 TERMINALS WITH FACTORY -- INSTALLED CONTROLS FURNISHED BY CONTROLS SUBCONTRACTOR. 2. TERMINAL UNIT ASSEMBLY INCLUDES AIR VALVES, CONTROLLERS AND COMPACT MIXING -- ATTENUATOR SECTION, FLOW SENSORS ON BOX INLETS. TERMINAL UNIT COLD AIR VALVES SHALL BE ABLE TO OPERATE AT ANY POINT WITHIN THE SETPOINT RANGE INDICATED IN THE SCHEDULE. INITIALLY SET MAXIMUM AND MINIMUM CFM'S AT VALUES INDICATED ON THE PLANS FOR EACH INDIVIDUAL TERMINAL. 3. SOUND POWER VALUES SCHEDULED ARE THE MAXIMUM ALLOWED DISCHARGE SOUND POWER AT THE "MIXER —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x12 SOUND POWER 2 4 6 74 67 55 ADDITIONAL SOUND ATTENUATION NOT REQUIRED REMARKS 1. DESIGN BASED ON NAILOR MODEL 3001 TERMINALS WITH FACTORY — INSTALLED CONTROLS FURNISHED BY CONTROLS SUBCONTRACTOR. 2. TERMINAL UNIT ASSEMBLY INCLUDES AIR VALVE AND CONTROLLERS. FLOW SENSORS ON BOX INLETS. TERMINAL UNIT COLD AIR VALVES SHALL BE ABLE TO OPERATE AT ANY POINT WITHIN THE SETPOINT RANGE INDICATED IN THE SCHEDULE. INITIALLY SET MAXIMUM AND MINIMUM CFM'S AT VALUES INDICATED ON THE PLANS FOR EACH INDIVIDUAL TERMINAL. 3. SOUND POWER VALUES SCHEDULED ARE THE MAXIMUM ALLOWED DISCHARGE SOUND POWER AT THE OUTLET, RATINGS AS CERTIFIED BY ARI (STANDARD 880 -98) FOR OCTAVE BANDS 2, 4 AND 6 WHEN THE TERMINAL IS MEASURED AT ARI DESIGN CFM WITH PRIMARY AIR AT 1.5" PRESSURE DROP. 4. PROVIDE CONNECTING DUCT FROM EACH INLET TO THE ASSOCIATED COLD MEDIUM PRESSURE TRUNK DUCTS AS PER SCHEDULE ABOVE. WHERE SPACE IS NOT AVAILABLE FOR ROUND DUCT, PROVIDE FLAT OVAL OR RECTANGULAR DUCT OF EQUAL OR GREATER CROSS SECTION AREA WITH NECESSARY TRANSITIONS. IF A LARGER SIZE IS INDICATED ON THE PLANS, PROVIDE THE LARGER SIZE AND TRANSITION TO THE INLET SIZE 3 FEET UPSTREAM OF THE TERMINAL. 5. PROVIDE OUTLET DUCT, SIZE AS SCHEDULED, UNLESS NOTED OTHERWISE ON DRAWINGS, FROM TERMINAL (MIXER) OUTLET TO THE POINT DOWNSTREAM THAT A DIFFERENT SIZE DUCT IS INDICATED ON PLAN. WHERE NECESSARY DUE TO SPACE RESTRICTIONS, PROVIDE DIFFERENT SHAPE DUCT WITH THE SAME CROSS SECTION AREA. OUTLET DUCT IS TYPICALLY LARGER THAN TERMINAL DISCHARGE. PROVIDE ALL NECESSARY TRANSITIONS. 6. SEE DETAIL 5/505 FOR MINIMUM CLEARANCE REQUIREMENTS. SOUND ATTENUATOR (SA) SCHEDULE MARK NUMBER SA--1 SA -2 SA -3 SA -4 SA -5 SA -6 LOCATION AHU -1 AHU -2 AHU —3 AH U-4 1st FLR ROOM 1109 1st FLR ROOM 11 J 10 ATTENUATOR BANK SIZE FT x FT 96x96 72x72 96x96 72x72 48x18 84x24 LENGTH FEET 4.5 5 4.5 5 7 7 UNIT WIDTH MAXIMUM x HEIGHT PD INCHES 1N /H20 48x48 (4) 48x36 (2) 36x24 (2) 48x48 (4) 48x36 (2) 36x24 (2) 24x18 (2) 42x24 (2) 0.25 0.25 0.25 0.25 0.22 0.22 MAX FV FPM 1150 1150 1150 1150 2000 2000 AIR QUANTITY CFM 60,000 35,000 60,000 35,000 6,500 14,835 MINIMUM DYNAMIC INSERTION LOSS RATING, dB OCTAVE BAND CENTER FREQUENCY HERTZ RATING 63 10 10 10 10 13 13 _ 125 12 12 12 12 15 15 250 21 21 21 21 24 24 500 23 23 23 23 28 28 1000 22 22 22 22 27 27 2000 16 16 16 16 20 20 4000 12 12 12 12 18 18 8000 10 10 10 10 13 13 BASIS OF DESIGN LAC MODEL "CLEAN FLOW" TYPE HLFM 1AC MODEL "CLEAN FLOW" TYPE HLFM IAC MODEL "CLEAN FLOW" TYPE HLFM IAC MODEL "CLEAN FLOW" TYPE HLFM IAC MODEL "CLEAN FLOW" TYPE HLFM IAC MODEL "CLEAN FLOW" TYPE HLFM DATE BOE /NG° ISSUE FOR PERMIT AfOFFMAN NGINEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 JOB NO. DWG NO. 150680-01 9-90—M2C RECEIVED APR 0 9 2007 PERiva ,„ COMP NO. ELECT. 1206 EREN 1 B5 =111■11111iie i Ali Mir O I! 1_ •)• RN* .� KOMI 12010 H- -0/325 W1 C- 330/1100 011 RENCE C -300 1000 C -230 860 C6 H -0 470 C-230 840 �� Cl■ � II • i : :4 1 18 14 IEUI C ON { rr FENCE �� �t lC� �Iy ii!�IR1 i u ►� � . q i *1 30� �,� ►� IKTYAII!J 4. l I ... � Q i it nlr ��► � � 1 ; l II 1.,..r.=. ririg! UK UP STAIR C--150 450 200/ \200/ \200/ \200/ 200 C -250 1000 B3 CD6 CD6 W1 H- 0/1500 E4 C- 450/1480 H -0 300 0-350 1500 H -0 500 C-450 1000 24/10 CD3 25> < ORIG 9 -90 RENOVATION REVISION J #150680 -01 COFFMAN BY APPROVED M. SOTURA DATE 04.05. 7 (TY 2) SYM H -0 270 C--200 0 -600 1220 REVISION H--O 300 BY 350 APPROVED DATE H- 0/2000 C-- 450/2000 24/10 UP ni.1 PI I 1 f f 1 1 I , �� f f II C -230 600 FIRST FLOOR DUCTWORK PAN SCALE: 1/8 "= 7' -0" Mt7E7Alig® H -0 200 H -0 750 C -160 440 ACCEPTABILITY THIS DESIGN AND /OR IRCATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED 01.15.07 DATE SUBTITLE 01.15.07 TITLE H -0 450 C -150 600 MECHANICAL MASTER (A) H -0 900 C -150 710 m H-0 700 � C -660 1320 /CD6\ \210 PROVIDE AIR CONDITIONING UNIT ISSUE FOR PERMIT ALL DUCTWORK OFFSETS BELOW BEAMS SHALL BE SHORT RADIUS OR MITERED ELBOW CONSTRUCTION TYPICAL. PROVIDE BOARD INSULATION ON EXPOSED RECTANGULAR DUCTWORK. DOUBLE OFFSET TRANSFER BOOT. FIRST FLOOR DUCTWORK PLAN 9 -90 RENOVATION BUILDING 9.90.1 COL. a- Fi1-13 W1 C2 AFOFFMAN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 - 1625 206 623 0717 Fax 206 624 3775 LEGE 0 N ril= .. • CD6 125 H -0/510 0- 80/925 GEN C0\ DEV. CENTER,WA SHEET D SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST TRANSFER BOOT W /WALL GRILLE, SEE DETAIL 1/M506 TRANSFER BOOT, SEE DETAIL 6/M506 MAN BARS, SEE DETAIL 3/M506 THERMOSTAT - WALL MOUNTED DUAL -DUCT VAV TERMINAL UNIT (LETTER INDICATE BOX SIZE AS PER M2C) VOLUME DAMPER CO2 SENSOR PRESSURE TRANSMITTER M D SOUND MACHINE (BY BOEING SECURITY) DWG NO. SMOKE DETECTOR DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDITIONAL INFORMATION. ERAL TERMINAL UNITS: COLD DUCT BRANCH SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT BRANCH SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. STRUCTION DOTES (3) TEMPERATURE CONTROL PANELS STACKED ON TOP OF EACH OTHER BY CONTROLS CONTRACTOR. ROUTE SA DUCT ABOVE SOFFIT TO SIDEWALL GRILLES WITH OPPOSED BLADE DAMPERS (OBD). SMOKE DETECTOR BY ELECTRICAL CONTRACTOR. 1M12 1M13 0 KEY PLAN SCALE: NONE SCALE; 1/8"=1'-0" CURRENT REVISION OTES 1M10 JOB NO. 150680-01 'YMm` o Ric 9- 90 --1M10 DATE 04.05.07 COMP NO. ern O F T j _ 6Ox18I ORIG - .w ,i wi wl � 11F12 ' T 24/12 " I' * I !I H -0 /600 C- 350/1200 H -0/250 C- 190/600 H-0/230 C-220/700 H -0/220 C- 210/600 H -0/160 C-- 160/420 H-0/455 C- 230/880 (TYP 4) H 0 760 C-- 150/245 (TYP 2) H -0/185 C- 175/350 H-0/220 9 -90 RENOVATION REVISION J #150680 -01 COFFMAN 1 M. SOTURA 1 04.05.07 STAIR 11K6 UP H-0 /300 C- 350/700 FIRST FLOOR DUCTWORK PLAN SCALE: 1/8"= V-0" 0 1 --Asr4 oc H -0/350 TYP 3) ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. H -0 i C- 220/600 Ir 62/12 300 700 ...cLa...ww rablirfla la Pk =Mamma r. PROVIDE BOARD INSULATION AT ALL EXPOdED DUCTWORK. 'TYPICAL THROUGHOUT. ALL DUCTWORK OFFSETS BELOW BEAMS SHALL BE SHORT RADIUS ELBOW CONSTRUCTION TYPICAL. DOUBLE OFFSET TRANSFER 1300T. ACCESS DOOR THIS SIDE. OFFSET IN VERTICAL ISSUE FOR PERMIT DRAWN COFFMAN CHECKED M. SOTURA CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTITLE TITLE arrart el 01 .arourd.1 H H -0/520 C-- 500/1000 H- 0/1040 C- 330/830 H -0/700 C-- 650/1320 0 C- 375 /720 MECHANICAL MASTER 375 CONSTRUCTION W1 NOTES C2 REFER TO DETAIL 2/M502 PENETRATION DETAIL REFER TO DETAIL 3/M502 PENETRATION DETAIL PROVIDE AIR CONDITIONING UNITS. SMOKE DETECTOR BY ELECTRIC CONTRACTOR. HOLD DUCTWORK TIGHT TO STRUCTURE ABOVE *OFFMAN 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR DUCTWORK PLAN 9 -90 RENOVATION BUILDING 9 -90.1 LEGEND rol SQUARE CEILING DIFFUSER 0 e0 E=1 TRANSFER BOOT W /WALL GRILLE, SEE DETAIL 1 /M506 TRANSFER BOOT, SEE DETAIL 6/M506 MAN BARS, SEE DETAIL 3/M506 Q THERMOSTAT -- WALL MOUNTED D SMOKE DETECTOR DUAL-DUCT VAV TERMINAL UNIT (LETTER INDICATE BOX SIZE AS PER M2C) VOLUME DAMPER CO2 SENSOR T PRESSURE TRANSMITTER SOUND MACHINE (BY BOEING SECURITY) KCD6) 125 H -0/510 C-80/925 COL. F- L/1 -13 DEV. CENTER,WA LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDITIONAL INFORMATION. R . DUCTWORK RISE DUCTWORK DROP GENERAL DOTES TERMINAL UNITS: COLD DUCT BRANCH SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT BRANCH SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWIF\ M2C, MECHANICAL SCHEDULES M505, HVAC DETAILS SHEET 0( 0 1M10 foy 1M12 1M13 KEY PLAN SCALE, NONE SCALE: 1/8"=1'-0" CURRENT REVISION 1M11 JOB NO. 150680-01 DWG NO. GS PERWI CE+y E r,; 4 8' 4' 0 4' 8' 16' SiMBOL 9-90--1M11 IECENED crry o : TI IK APR 0 9 2007 DATE 04.05.07 COMP NO. H -0/260 C -90 300 H 960 C-330 1260 H--0 710 C -650 2180 (CD6 210/ D6 210 REVISION mmmmmWmMigumMmmm SYM ORIG 1 9 -90 RENOVATION J #150680 -01 COFFMAN M. SOTURA 04.05.07 BY APPROVED DATE SYM - O 11K9 REVISION i _ -_ -- __ -_ -_ -- __ -1 __ FIRST FLOOR DUCTWORK PLAN SCALE: 1/8"- 1'-O" BY APPROVED DATE KCD1 150 42/24 UP 40/16 UP " CONFERENCE 12L3 26/12 28/12 1►� Il i! 12 10�' i 1� 1 � CD2 M^r . � Wi no.. lr II -. I GD3 220 nI — _ II CD3 k ∎ ' 3 220 , _ � 0 ill , E OP i i UMW" �.� MMMWMINOMMUMEmmmMWM 34/12 38/12 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 14/10 DRAWN COFFMAN CHECKED M. SOTURA E TYP) CHECKED APPROVED APPROVED 12/6 180 18/12 H -0 750 C -500 1400 . _ H-0' 900 C-600 18.0 jig CD2 I 160 i 8 14ROOM IOM1=11 Ginn <r11 -- -- +--- -- -- -- -- CL/-\) "ICI CONTROL ~ BIKE RACK STATION 12/12 CD11 150, CD11 ►. 150 H 0 500 C -350 920 DATE SUBTITLE 01.15.07 01.15.07 H--0 260 C -90 300 H-0 280 C-230 620 H--0 400 C -250 750 H -0 370 C -360 H -0 995 C -330 1220 H -0 440 C -420 1250 ISSUE FOR PERMIT ACOFFMAN N G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR DUCTWORK PLAN LEGE TITLE MECHANICAL MASTER 9-90 RENOVATION BUILDING 9 -90.1 COL. L-- S/1 -13 DEV. CENTER,WA \D SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST TRANSFER BOOT W /WALL GRILLE, SEE DETAIL 1/M506 0 [71 TRANSFER BOOT, SEE DETAIL 6/M506 MAN BARS, SEE DETAIL 3/M506 Q THERMOSTAT -- WALL MOUNTED 1 DUAL-DUCT VAV TERMINAL UNIT (LETTER INDICATE BOX SIZE AS PER M2C) VOLUME DAMPER CO2 SENSOR PRESSURE TRANSMITTER FIRE DAMPER (1 HOUR) I FD CD 125 6 H- -0/510 C- 80/925 GENERAL DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDITIONAL INFORMATION. VOTES TERMINAL UNITS: COLD DUCT BRANCH SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT BRANCH SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS CONSTRUCTION KEY RAN SCALE: NONE 8' 4' 0 © O1 1M10 1M11 1M13 OTES DWG NO. SCALE: 1/8"=1'-0" CURRENT REVISION SYMBOLFy R I 0 SHEET 1M12 JOB NO. 150680-01 9 -90 -1 M12 DATE COMP NO. REctiveD 1 APR 0 9 2007 16' 04.05.07 r. i • `i 1 i a t r k I ��- SYM ORIG 9-90 RENOVATION FFICE At& II Ir•� MA Mt Rik ,1 IIKKOR MINK* ■I=r— ■ MINN I I _1 CD3 r1 (� %Alio jw.imikr (CD2 B8 1 — -- Illl�I�`► � Atrlil - - 1 D9 I WILL • 4n 3 3 Ir mo •uiii w 1 ■ U [ ■l�1�1I I a --- G ill II 1i_ 1 Emu � iii 1 Nii -Napi ' 111 ;1_I_• 18 14 r1.. l• S i, 1♦ A ... U 1 • a Cr r,. r rr i - - -r - i - - - - -r. 1 .:1 MEV 0 i ■ —E• Q I�ltl1•I ; 1 '` II AR 20 rrrr 11111.E A5 A il �t! Wit! pumi I�■■I■I n 4 r w (CD7) 275/ CD7 275 CD7 275 CD7 275 CD6 210 IF • FFICE r$ 1 ,,Ir�ll 380 CD7 190 CD7 Afilak 275 W� { 18/12 0 I Itl1Q! I ill 21 Ala w CD7 ,190, C -230 800 CD1 100 24/10 12/12 OFFICE CD2 115 OFFICE CD2 115 OFF 22 -OF CD1 CD2 200 (TYP 4) FFICE w CD2 115 P2 12/6 AIL 12 10 i 400 �-J - -- 120 : Agar t I1 ® _ i J.1� l� i�.� I_ u Nib 600 140 1 i • r�.rw•rlw.. —.. m w � �ff 16x10 I 1 , ' t ELEC. EN 12/10 1 115 / 40 CD9 2110 12/ Ain C CD7 II 50 50 ■ r i i 1 a MEN CD2 \ 210 / (TYP 4 CAFE 21D6 22/10 w FEC 22D6 w 750 ti 14/6 TYP 3 CD7 250 0 DN STAIR 21 C6 1 22/10 21E6 • 12/_6 ,. �► 210 CD2 185 CD6\ /CD6 160 1 < _CONFERELiC u \ ti H--0 885 U -64 1 1 20 CD2 210 H -0 470 C -460 915 18/10 CD2\ 210/ Aga w 0 -230 800 CD6 CD6 � (CD6 ,60 160 \210/ 120 120 120 CD6 160 MI KO 0 ENI CD2 210 a C■ 00 C c1 d.. CE CD2 210 CD2 210 [V r 18 14 CD2 210 CD6 200 CD6 200 CD7 245 CD7 245 CD7 245 f W H--0 430 C-230 890 H--0 450 C -230 890 H -0 490 C -510 935 H -0 690 C-650 1300 REVISION J #150680 -01 H 0 260 C-120 18/10 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 H -0 390 S 100 H - 0 200 C -200 400 REVISION 24/12 H -0 400 C - 320 580 SECOND FLOOR DUCTWORK P SCALE: 1/8 1'--0" BY APPROVED DATE H-0/390 C- 250/840 H -0 450 I C -230 , , , ! ii TRANS, ER BOOT! (TYP) , , r , , , , , 1 1 1 , AN H 0 715 H -0 200 2 - E5 C -150 370 E3 C - 7 0 35 /775 /1470 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. A ISSUE FOR PERMIT DATE DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED DATE SUB1TTLE 01.15.07 01.15.07 TITLE 12/12 H -0 430 C -150 600 C -230 600 H -0 1115 C-230 860 SECOND FLOOR DUCTWORK PLAN 9-90 RENOVATION BUILDING 9 -90.2 MECHANICAL MASTER COL. A-- F/1 --13 ACOFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 - 1625 206 623 0717 Fax 206 624 3775 0 N Z ri= ••• 1-8° 25 25 H- -0/510 C- 80/925 CO DEV, CENTER,WA LEGEND 1 SHEET JOB NO. DWG NO. SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST TRANSFER BOOT W /WALL GRILLE, SEE DETAIL 1/M506 TRANSFER BOOT, SEE DETAIL 6/M506 MAN BARS, SEE DETAIL 3/M506 THERMOSTAT - WALL MOUNTED DUAL -DUCT VAV TERMINAL UNIT (LETTER INDICATE BOX SIZE AS PER M2C) VOLUME DAMPER CO2 SENSOR DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDITIONAL INFORMATION. GENERAL COTES TERMINAL UNITS: COLD DUCT BRANCH SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT BRANCH SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWI \GS STRUCTIO (3) TEMPERATURE CONTROL PANELS STACKED ON TOP OF EACH OTHER BY CONTROLS CONTRACTOR. ROUTE 140 SA DUCT IN SOFFIT TO (3) 14x6 SIDEWALL GRILLES WITH OBD'S. 2M12 2M13 0 KEY PLAN SCALE: NONE 8' 4' 0 CURRENT REVISION \ NOTES 4' 2M10 SCALE: 1 /8 " =1' -0" 8' SYMBOL pp D ATE ur iu 04.05.07 150680 -01 9-90-2M10 COMP NO. RECEIVED cil t' OF TI IV %in! 'APR 0 9 2007 PERMIT Gtwi\ 16' • SYM ORIG REVISION 9 -90 RENOVATION J #150680 -01 BY COFFMAN APPROVED M. SOTURA 04.05.07 1111111 { I Orion II■ II[► mmo EM 0 1I rnrr�. U 3 MEA K) 1 a DCN 22K7 .�1t7i• >iri 21 �! rok. ERENCE C -230 ' 80 12 6 STO. \ 27,1h L I i Ala I rral,NW. • 1f l� �►�� ■ >� Poor' maw r 1111111 11111 111111 aIIIIIINIIHmARIL I'l II grm 11 w i RG9 w �II■IlI•■ aim 32/14 NET r ■111 M �I 0 f l I 'KOK NI KO • 1 • CD6 CD6 210 CD6 210 W2 J11 CD6 210 CD6 210 CD6 210 CD6 210 V N W2 G11 IW CD2 210 CD2 210 r CD3 300 120 1075 2 1 F8 CD2 \ (TYP 6) • 21 16/ K8 H7.0 C 1500 Fir rm. � 0 550 r -440 1170 0 1 1 I ..- ...■r D,c) G9 z4 /iz CD3 350 C 120 I 22H9 NFERENCE CD3 \ (TYP 4) CD2 210 r 1100 I A36/16 U 40/I6 , , X 40/16 f UP OT DE OLD D 100 24/16 I I Nal CD3 220 -- -=1 36/161 UP 42/ UPON 164 UP & IA N 40, 16 40416 46X14 (HO UP&D UP 68/14 (CO C IlIvIMM■V VI VI N ECK) ER DECK) N C-320 580 'D2 \ (TYP 2 CD3 300 H -0 235 C-230 CD3 300 520 W2 H -0/480 J4 C-460/910 6i w a W2 K3 44/14 CD3 300 CD3 300 \„..k o i 4- H -0 945 0--900 1800 I I C -380 IT E 120 120 w OPEN OFFICE 21G5 :TYP) "_1 12/12 Ark � UDDF � (C 300 I CD3 300 CD3 300 CD3 300 {l- 205 CD7 245 CD7 245 CD7 245 CD7 245 H--0 1700 C -580 2310 H-0 655 C -625 1260 EEC K oN) 210 (CD6) 210 CD6 <10 \` H -0 655 C-625 1260 H -0 505 C -330 C H -0/475 C- 450/900 f - - OPEN 635 ▪ r REVISION hi -- ----- , 1 1. t 120 T 120 ® CD12 I '; N OFFI I E 250 SECO \D FLOOR DUCTWORK PLA SCALE: 1/8 r -o° BY 120 APPROVED DATE STAIR 1 22x6 I2 /I2 v C DI2 250 Airiffer,Aw H -0 400 EXPIRES 1 /10 /09 Im•wlil mww•IN■S IN id H -0/945 C -900 /1800 OPEN OFFICE 21 K5 I ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 925 DATE H -0 400 DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 TITLE SUBTITLE CD6 205 H -0 830 0 -150 650 ISSUE FOR PERMIT MECHANICAL MASTER 9 -90 RENOVATION BUILDING 9 - 90.2 COL. F- L/1 -13 W2 C2 *OFFMAN GIN EE RS 6 I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR DUCTWORK PLAN LEGE p TRANSFER BOOT, SEE DETAIL 6/M506 MAN BARS, SEE DETAIL 3/M506 THERMOSTAT - WALL MOUNTED DUAL-DUCT VAV TERMINAL UNIT (LETTER INDICATE BOX SIZE AS PER M2C) VOLUME DAMPER .SS 1-0 DEV. CENTER,WA - 1 H -0/510 C- 80/925 C0\ SHEET JOB NO. REFERE DWG NO. SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST TRANSFER BOOT W/WALL GRILLE, SEE DETAIL 1/M506 CO2 SENSOR DUCTWORK RISE DUCTWORK DROP DIFFUSER/GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDITIONAL INFORMATION. GBERAL NOTES RETURN AIR OPENING ABOVE TO WEST PENTHOUSE. TERMINAL UNITS: COLD DUCT BRANCH SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT BRANCH SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. STRUCTION NOTES CD 0 KEY PLAN SCALE: NONE CURRENT REVISION CE DRAWINGS 2M 1 1 150680-01 "" RECEIVED MY OF 71 A 'APR 0 9 2007 COMP NO. PERMIT GEN 16' DATE 04.05.07 a c. t. w R12 CD3 24/16 w W /FD 12/6 w 24/16 �1 CONFER /CD3 \300 H -0 250 C 68 CD2 w CD6 CD6 205 K cas 205 CD6 205 CD6 205 CD6 205 /CD6 �2D5 CD6 205 CD6 205 FEC � � OPEN 0 E ® CD3 300 CD3 300 3L1 0 C FACE C- H -0 335 C -310 H -0 8 C--865 1725 CO N 735 M11 0 CD3 300 CD3 300 120 CD3 300 CD3 300 a RG9 OFFICE 120 H -0. 630 CD3 300 300 H 0 550 C 340 1180 CD3 300 CONF R L9 H -0/360 C - 230/745 CD12 300 r t 1 w FD D10 225 D10 t FD 12/6 24/16 Rik w W /FD 0 580 H -0 504 (HOT 450 C -3 0 1000 170 r OFFICE CD1i 185 WORK ROOM CD2 185 CD3 300 01111•11M11•0111.11 114 5 6/ 14 1 � t D 1 I I D ] 11 /Ma 250 N iff C06 185 CD6 185 CD7 250 CD7 250 0 H 1140 C -450 1600 H--O 860 C-330 1230 \195/ (TYP 4) DD LE /C D3) \300/ OP 1 0/1 0 ___________1 PI i 40/14 UP IA SYM ORIG 9 -90 RENOVATION REVISION J4150680 -01 __ .. __ .. ...�...._ 42/24 UP&DN 40/16 UP &DN 440/16 UP 225/ ; ll t24Y12 l SECOND FLOOR DUCTWORK PLAN SCALE: 1/8'= 1' -0' giArater,Aw® H -0/350 C- 340/905 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. ISSUE FOR PERMIT ■ DATE DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED CD2 \185/ DATE 01.15.07 01.15.07 SUBTITLE TITLE CD 250 250 H MECHANICAL MASTER H 0 920 C -880 1755 H -0 790 C-750 1500 0 1140 C -230 925 N FFMAN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 - 1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR DUCTWORK PLAN 9 -90 RENOVATION BUILDING 9 -90.2 COL. L- S/1 -13 DEV. CENTER, WA LEGEND O 0 1-do 2 H -0/510 C2 C- 80/925 FD FIRE DAMPER (1 HOUR) R DUCTWORK RISE D DUCTWORK DROP GENERAL NOTES RETURN AIR OPENING ABOVE TO EAST PENTHOUSE. TERMINAL UNITS: COLD DUCT BRANCH SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT BRANCH SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS C SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST TRANSFER BOOT W /WALL GRILLE, SEE DETAIL 1 /M506 TRANSFER BOOT, SEE DETAIL 6/M506 MAN BARS, SEE DETAIL 3/M506 THERMOSTAT - WALL MOUNTED DUAL -DUCT VAV TERMINAL UNIT (LETTER INDICATE BOX SIZE AS PER M2C) VOLUME DAMPER CO2 SENSOR DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDITIONAL INFORMATION. STRUCTION VOTES 13 0 2M10 2M10 2M11 Ki j 2M13 0 0 0 KEY PLAN SCALE: NONE CURRENT REVISION SHEET JOB NO. SCALE: 1/8"=1'-0" DWG NO. 2M12 150680 --01 9- 90 -2M12 EcmveD CPI's' o TI wNi APR 0 9 2007 8' 4' 0 4' 8' 16' SYMBOL DATE �� 03.30.07 COMP NO. C C C u c c a I_SI MN= NO 111If ! v IIIr1w -11I ■��� NM NO HUDDLE \ \ R n Al.!Ar 1 BY APPROVED warms" ft liI OPEN OFFICE H —O 1000 C -330 1365 H-0/360 C- 230/745 REVISION C- 260/790 X9 ' 14/12 H -0 7,0 C -35 1 705 CDfp 225 12/6 STAIR C -260 790 APPROVED REVISION 9-90 RENOVATION J 11150680 -01 COFFMAN 140 UP TO EF-4 SG1 w (TYP 3) 12/6 C -200 600 RENCE W5 OFFICE H 250 C -170 510 }WIRES 1 /10 /09 CD3 300f \300/ /W2\ H -0/910 \V3/ C- 860/1725 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED T HUDDLE DATE 01.15.07 01.15.07 0/820 780/2390 SECOND FLOOR DUCTWORK PLAN CURRENT REVISION JOB NO. SYMDOL R I G 150680 -01 9- 90- -2M13R H-0/860 C-450/1880 H -0 470 C -450 900 H -0 1060 C --1000 2025 (TYP 4 0 /CD3\ \300J - n: H— +/950 C- 900/1800 i J 36/16 UP &DN 36/16 UP Tr H -0 380 22/10 181 IW SECOND FLOOR DUCTWORK PAN £ i i :J I11�.:II+!�! II WI C4J-' H -0 C -230 360 745 H -0 335 C -310 735 APPROVED APPROVED 000 365 H 1060 C -230 H C C H -0 400 150 MECHANICAL MASTER 865 555 ISSUE FOR PERMIT 9 -90 RENOVATION BUILDING 9 -90.2 COL. S— Y/1 -13 COFFMAN NGINEEBS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 - 1625 206 623 0717 Fax 206 624 3775 LEGE O 8 0 4 : 1 ?I� 0 2 H -0 570 CZ C -8925 GEC DEV. CENTER,WA �I D SQUARE CEILING DIFFUSER LINEAR SLOT DIFFUSER ROUND CEILING DIFFUSER CEILING GRILLE RETURN OR EXHAUST TRANSFER BOOT W /WALL GRILLE, SEE DETAIL 1/M506 TRANSFER BOOT, SEE DETAIL 6/M506 MAN BARS, SEE DETAIL 3/M506 THERMOSTAT -- WALL MOUNTED DUAL —DUCT VAV TERMINAL UNIT (LETTER INDICATE BOX SIZE AS PER M2C) VOLUME DAMPER CO2 SENSOR PRESSURE TRANSMITTER SMOKE DETECTOR DIFFUSER /GRILLE TAG. TOP NUMBER INDICATES TYPE, BOTTOM NUMBER INDICATES CFM. SEE DIFFUSER AND GRILLE SCHEDULE. VARIABLE VOLUME TERMINAL UNIT TAG. HOT AND COLD DUCT MINIMUM AND MAXIMUM CFM VALUES INDICATED. SEE DETAIL 5/M505 FOR ADDITIONAL INFORMATION. ERAL NOTES EXISTING RETURN AIR OPENING BETWEEN FIRST AND SECOND FLOOR. TERMINAL UNITS: COLD DUCT BRANCH SIZE SHALL BE AS SCHEDULED ON DWG M2C UNLESS INDICATED ON THIS DRAWING. HOT DUCT BRANCH SIZE SHALL AS PER DETAIL ON DRAWING M505 AND BE BASED ON THE HOT DUCT MAXIMUM CFM INDICATED UNLESS SIZE IS INDICATED ON THIS DRAWING. AIR BALANCING SHALL BE DONE WITH MAXIMUM COOLING AIRFLOW AND HOT AIR DECK CLOSED. IN HEATING MODE DIFFUSER AIRFLOW CAN BE SLIGHTLY HIGHER THAN COOLING AIRFLOW. REFERENCE DRAWINGS CONSTRUCTION COTES (3) TEMPERATURE CONTROL PANELS STACKED ON TOP OF EACH OTHER BY CONTROLS CONTRACTOR. SMOKE DETECTOR BY ELECTRICAL CONTRACTOR. ROUTE 140 SA DUCT IN SOFFIT TO SIDEWALL GRILLES WITH OBD'S. © O1 2M10 2M11 2M12 2M13 0 0 0 0 8' DWG NO. KEY PLAN SCALE: NONE 4' 0 4' SCALE: 1/8"=1' —0" 8' c Ti ILA APR 0 9 2007 COMP NO. 16' �.E DATE 03.30.07 s; , 1 ( I i E:1 1- 1 /2 "CHWS & CHWR mom.. ft rrftmormo .1 CONFERENCE 12C11 T__12 DOD WORK SPACE 11C11 SOSAC LUE TEAM 11D11 SOSAC RED TEAM 11E11 SOSAC SERVEI 13C10 10 VTC CONFERENCE 11C10 D4 r � v=+� L _ILJ va- L_24_1 1 -1 /8 SUPPLY --� I 2- 1/8'�� RETURN ( JAN. 11E7 MECH. •1106 APPROVED ELECT. 12D6 SCALE: 1 /8 "= 1' -0" SYM ORIG 9 -90 RENOVATION REVISION J #150680 -01 COFFMAN DATE UP STAIR 1 1X6 r �r STORAGE 11E6 FIRST FLOOR HVAC PIPIN G FEC PLAN 4 ______ AA ■•••ftft10444 ft AA ■•••••• A A AdOOA.Aft A ft lAd.ftWIMI•mt ftIOMAAA ft. ■•■• • BOE /Na° CONFERENCE 1185 DXPU ES 1 /10 /09 APPROVED BY ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION iS APPROVED DEPT. C OPEN OFFICE 11A5 DATE DRAWN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED — PO I DATE 01.15.07 01.15.07 SUBTITLE TITLE MECHANICAL MASTER ISSUE FOR PERMIT AcOFFMAN 6 I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR HVAC PIPING PLAN 9 -90 RENOVATION BUILDING 9 -90,1 COL. A- F/1 -13 DEV. CENTER,WA LEGEN J PC LPC MPC MPS CHWS CHWR oa a�— C-1 GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTIO PROVIDE REFRIGERANT LOOP WITH SHUT-OFF VALVES AND BYPASS FLOW CONTROLLERS FOR 2 XDO MODULES AND 2 FUTURE XDO MODULES. PROVIDE CHILLED WATER SUPPLY AND RETURN PIPING. PROVIDE NEW FLOOR MOUNTED A/C UNITS. NEW 3" CONDENSATE RETURN (PUMPED). SHEET JOB NO. DWG NO. COMPUTER ROOM COOLING UNIT # /FLR, BOTTOM LINE INDICATES LOCATION 13 0 1 M62 1 M63 KEY PLAN CURRENT REVISION CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT -OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN 1M60 NOTES 0 0 SCALE; NONE 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" SYMBOL ° RIG 150680 -01 9- 90 -1M60 COMP NO. RECEIVED CITY OF T( W A `APR 0 9 2007 PERMIT CEN DATE 04.05.07 t ( .t • - l apTt CC L SAC ti FERENCE i ' F12 2 "CHWS & CHWR CLASSIFIED CONTROL 11K11 2 "CHWS & CHWR CLASSIFIED CONTROL 12K11 MiM 0 CONFE 13J10 ; OSAS FERENCE 3G10 RENCE ------------ OFFICE 11K10 SOSAS RED TEAM 12J10 10 0 1--178 SUPPLY 2-1/8" RETURN SOSAS SERVER 11G10 VESTIBULE 11G9 SOSAS BLUE TEAM 11J10q 3/4" -125# MPC UP 2 "CHWS & CHWR OPEN OFFICE 11K9 I 0, i 0000 WOMEN 11F7 6 " CHWS & CH 4 "CHWS & CHWR -1 /2" 11 11H7 2 2 DCN SYM ORIG 9 -90 RENOVATION REVISION J11150680 --01 COFFMAN APPROVED SOSAU SERVER 11J7 DATE 1M4 2 6 "CHWS & CHWR UP IS&T BLUE TEAM G6 MEN 11E6 2-1/2 & CHWR IS &T RED TEAM 11H6 AC1 LAM "Z PM1 r 1 � 1 2 , 11 K8 1 ANCHOR 11J6 MECH. 12J6 ELEV. 3 "PC � 1 - 1/2" 1336 11" 3 CHWS & CHWR 1111■ i 1 1 r STAIR UP X 2 3/4' 1 U FIRST FLOOR HVAC PIPING PLAN CONFERENCE 13E4 4 "STEAM VENT UP 3" LPC CONFERENCE 4LFIAKig® 12L3 PRIVACY 12F4 7 E3(PiRES 1/10/09 WORK ROOM 1 13F3 1 OFFICE 11F3 OFFICE 1 12F3 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. OPEN OFFICE Dam DRAWN COFFMAN TPUMITO M. SOTURA ENGINEER APPROVED HUDDLE 11F2 i 1 ISSUE FOR PERMIT DATE CHECKED APPROVED DATE 01.15.07 01.15.07 SUBTITLE MECHANICAL MASTER FIRST FLOOR HVAC PIPING PLAN 9 -90 RENOVATION BUILDING 9 -90.1 COL, F- L/1 -13 FAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 LEGE CO REV. CENTER,WA SHEET D PC LPC MPC MPS CHWS CHWR v❑ X GEN ERAL REFEREE 1 M452, ENLARGED MECH RM PLANS M312, STEAM SYSTEM DIAGRAM STRUCTIO PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1-1/2" ISOLATION VALVES (TYPICAL). NEW 3" PUMPED CONDENSATE FROM 9 -96 BLDG NEW CEILING MOUNTED A/C UNIT FOR ELEVATOR MACHINE ROOM. NEW CEILING MOUNTED A/C UNIT FOR DCN ROOM. NEW 3" CONDENSATE RETURN (PUMPED). NEW 4" LOW PRESSURE STEAM CONDENSATE FROM PENTHOUSE. NEW 4" STEAM VENT TO PENTHOUSE. NEW 3/4" MEDIUM PRESSURE CONDENSATE FROM SECOND FLOOR. NEW 1" 60 PSI STEAM PIPE. REFRIGERANT LOOP PIPING WITH SHUT -OFF VALVES FOR 5 XDO MODULES. 13 0 O 1M60 1M60 1M61 1M62 1 M63 0 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" CURRENT REVISION JOB NO. 150680-01 DWG NO. KEY PLAN SCALE: NONE CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT-OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN ANCHOR COMPUTER ROOM COOLING UNIT # /FLR, BOTTOM LINE INDICATES LOCATION VOTES CE DRAWINGS 1M61 v NOTES SYMBOL R 1 G 9-90-1M61 COMP NO. RECEIVED art o;: TI 'Kwi.L E APR 0 9 2007 P .RM.IT c: I:; 1 L DATE 04.05.07 1; • „ i , 1 . o I =i .1• t, I E' 111- r15 1. 1 I 0 ; - 9 -90 RENOVATION REVISION r CLASSIFIED CONTROL 12K11 ESTIBULE 51 J #150680 --01 BY COFFMAN FEC MAIL 11L11 APPROVED M. SOTURA DATE 04,05.07 0 B IKE RACK STATION 11L RECYC. PEN OFFICE 11M10 EN OFFICE 1158 SYM 11K9 OFFICE 11M9 REVISION 3 "CHWS & CHWR 3 "CHWS & CHWR OFFICE 71R9 _ I 1 0, a (117 1 -1/2" BY VTC EQUIP. 11P7 IM FCS VTC 11R7 I Inoorronnonnt no In nnEr■ arm r■Nnorm no APPROVED -_ __ .,. ...._.I._.... __ ... _. CONFERENCE 1/2" 11 7 DATE t FIRST FLOOR HVAC PIPI SCALE: 1/8 "= 1' -0" 3 "CHWS & CHWR j 1 15,161 1-1/2" \1G PLA 0 CONFERENCE ? 3" V APPOWAFAW ® 12L3 [- CONFERENCE 11L3 CONFERENCE 13P3 PROGRAM STOR. 12P3 EXPIRES 1/10/09 Id on nonnorniren no In rion.rtro in ■amm.r. .1 11N3 WORK ROOM 12N3 1 APPROVED BY ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED OPEN OFFICE DEPT. FEC 12L2 OPEN OFFICE 11R5 DATE DRAWN COFFMAN CHECKED APPROVED APPROVED CHECKED M. SOTURA ENGINEER CONFERENCE 11M1 .� _. __ __ ._ -_ DATE 01.15.07 01.15.07 SUBTITLE TITLE ISSUE FOR PERMIT ACOFFMAN N GINEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR HVAC PIPING PLAN 9-90 RENOVATION BUILDING 9 -90.1 MECHANICAL MASTER COL. L- S/1 -13 DEV. CENTER,WA LEGEND PC LPC MPC MPS CHWS CHWR C GENERAL SHEET JOB NO. CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT -OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN COMPUTER ROOM COOLING UNIT # /FLR, BOTTOM LINE INDICATES LOCATION NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1 -1/2" ISOLATION VALVES (TYPICAL). PROVIDE NEW 3" CONDENSATE RETURN (PUMPED) PROVIDE 1 ", 60 PSI STEAM PROVIDE 3 "LPC 13 1 M60 1 M61 1 M63 0 0 0 KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" CURRENT REVISION DWG NO. sY ""ORIG 1 M62 9- 90 -1M62 REcemso IA APR 0 9 2007 DATE 04.05.07 COMP NO. • 1 ' t i s • 'If ir r, • • • S, • SYM ORIG 9 -90 RENOVATION REVISION en la HUDDLE [TI T11 OPEN OFFICE 1158 OPEN OFFICE 11U8 OFFIC 13T10 OFFIC 12T10 WORK ROOM 11T10 OFFICE CONFERENCE 13T9 FEC CONFERENCE 11W8 FE . f . .. err.rw.�aa.rrrr� _, w!w�.�wwwwr�airwww�wwrrw�� 4150680 -01 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 SYM REVISION cL BY -1 /2" CHWR 11 S7 MOTHER S ROOM 11T7 WOMEN'S CHWR CkFE M rr 11U7 �r « APPROVED DATE L.. �J 3 "CHWS & CHWR 1-1/2" STOR. 11T6 PIPING UNDERSLAB • A. } 2 0 II 1M452 MH #2 (UNDERGROUND) EC FIRST FLOOR HVAC PIPING PLAN SCALE: 1/8"= ,._u CONFERENCE i CONFERENCE 11W5 AirMEZAW® FEC r PRIVACY P IVACY 12S4 I" COMPRESSED AIRjJNDERGROUND) MPS ACCEPTABILITY THIS DESIGN AND /0F SPECIFICATION I APPRO' APPROVED BY OPEN OFFICE 11T5 CNDS DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED HUDDL 3" CONDENSATE (N ERGRO. D DATE 01.15.07 01.15.07 SuBTmE TITLE H 6" I25 PSI MPS(UNDERGROUND) ISSUE FOR PERMIT 9 -90 RENOVATION BUILDING 9 -90.1 MECHANICAL MASTER S- Y/1 -13 N FF AN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 FIRST FLOOR HVAC PIPING PLAN DEPT. DATE DEV. CENTER,WA LEGEND PC LPC MPC MPS CHWS CHWR v❑ C X GENERAL REFERENCE DRAWINGS C NSTRUCTION NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1-1/2" ISOLATION VALVES (TYPICAL). LOCATE ABOVE CEILING CAFE (NOT ABOVE HARD CEILING). PROVIDE 3" CONDENSATE RETURN (PUMPED). PROVIDE 1 ", 60 PSI STEAM 1M60 1 M60 1M61 1 M61 1M62 1 M62 KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" CURRENT REVISION SHEET JOB NO. DWG NO. CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT -OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN PIPE ANCHOR COMPUTER ROOM COOLING UNIT P /FLR, BOTTOM LINE INDICATES LOCATION OTES '"'`ORIG 1 M63 150680 -01 9- 90 -1M63 DATE 04.05.07 COMP NO, APR 0 9 2667 i= I SYM ORIG 9-90 RENOVATION REVISION IDFACE OFFICE OFFICE 22D11 OFFICE dAYYMMMMIlm17.■.M DN STAIR 21 C6 r WOMEN ANCHO ANCHOR loNFEREUCE_ —F- 1 FFICE 3FFICE 21 D11 mdammi■r■r......mmomPOMF.■■■■■•■..■■■■..■ 41150680-01 BY COFFMAN OPEN APPROVED M. SOTURA OFFICE 21B8 0 Fl CE 22E10 OFFICE 1E1° DATE 04.05.07 SYM OFFICE 22B10 1 WAITING 21C10 j OFFICE OFFICE M.7mImmilTWWWY■MWEIEIM CI 21D10 21E9 1 REVISION OFFICE 21B9 WORK ROOM 21C9 OFFICE 2109 CONFERENCE 23E9 BY APPROVED CAFE 2106 SCALE: 1/8"= 1 DATE FECcAp — •■■••■•P 6"MPS SECOND FLOOR HVAC PIPING PLAN AIR 6"MPS 10" CHWS 10" CHWR 3" PUMPED CONDENSATE GUIDE 3" EC GUIDE ..■m■pm. AMZEEZAW® 8/.3 8/3 midillimmmWww0.i.mm.MMimmmiWmimt■rrwimMimmiwan. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. OPEN OFFICE 21A5 HUDDLE 21A2 MIKIMMWEIOXIMMTI■Mft,m■■■..M.MMWMPWW C78 C78 C78 C7 ml 1•1•1•1•1•1•1.1.. DATE SUBTITLE 01.15.07 ISSUE FOR PERMIT (a) SECOND FLOOR HVAC PIPING PLAN AFOFFMAN NGINEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 LEGEND PC — LPC MPC MPS CHWS CHWR r)(1- Cf /AC 1) \K8 GENERAL NOTES REFERE CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT-OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN COMPUTER ROOM COOLING UNIT #/FLR, BOTTOM LINE INDICATES LOCATION ) STEAM TRAP 6.5 CURRENT REVISION DWG NO. PIPE GUIDE PIPE ANCHOR DIRECTION OF FLOW CE DRAWINGS CONSTRUCTION \OTES INSULATE EXISTING 6" STEAM LINE REROUTE STEAM PIPE AROUND STAIRWAY PROVIDE NEW STEAM TRAP PROVIDE NEW PUMPED CONDENSATE PIPE PROVIDE LOW POINT 1-1/2" DRAIN VALVES FOR CHWS & CHWR TERMINATING NEAR A7 2M60 2M61 2M62 2M63 0 0 KEY PLAN SCALE: NONE SCALE: 1/8"=1'-0" "'" RIG COMP NO. RECITISEI cirri TI lkW1ILA 'APR 09 2007 pazmyi, CE, CHECKED APPROVED Dams 1/10 69 DRAWN COFFMAN CHECKED M. SOTURA APPROV D 01.15.07 9-90 RENOVATION BUILDING 9-902 MECHANICAL MASTER COL, A-F/1-13 DEV. CENTER.WA JOB NO. 150680-01 9-90-2M60 DATE 04.05.07 S . 5 . cf C. CEPTABlLITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN MAN ° 0j 15.07 TRECKED M. SOTURA 01.15.07 - APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED SYM ORIG 9 -90 RENOVATION REVISION FEC J#150680 -01 OPEN OFFICE 21F8 OP N OFFI E m omma.ad -_— 3 "CHWS & CHWR -1 /2' 6" MPS _. -_ ma 6 "MPS �ni °iiNiu���iu� VTC -OCC CONFERENCE 21H91 CONFERENCE 3/4 "MPC DN 4 "MPS UP EQU 3 "CHWS & CHWR 1 -1/2 "CHWS & CHWR 6 "CHWS & HWR UP & DN CONFERENCE WOMEN 3 "CHWS & CHWR 3 "CH S &CH R STAIR STO. 22E __: o Q D n CONFERENCE OFFICE OFFICE _ __,__ � ._ SECOND FLOOR HVAC PIPING PLAN SCALE: ,ie = 1'-0" 3 "CHWS & CHWR 4 "LPC UP C78 C78 C78 C78 C78 V �- 4 "STM VENT DN WORK ROOM 23F3 OPEN OFFICE 21K5 I 1 OPEN OFFICE 21 G5 C78 C78 C78 C ISSUE FOR PERMIT SUBTITLE TITLE CO FFMA N N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR HVAC PIPING PLAN 9-90 RENOVATION BUILDING 9 -90.2 MECHANICAL MASTER COL. F- L/1 -13 DEV. CENTER,WA LEGEND PC - LPC - MPC MPS CHWS CHWR 01--- C-I-- GENERAL REFERE CONSTRUCTION NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1-1/2" ISOLATION VALVES (TYPICAL). NEW CEILING MOUNTED A/C UNIT FOR DCN ROOM. PROVIDE NEW 1-1/2" CONDENSATE RETURN PROVIDE 4" STEAM CONDENSATE RISER TO PENTHOUSE. PROVIDE NEW 4" STEAM VENT TO ROOF. PROVIDE 3/4" MEDIUM PRESSURE CONDENSATE. CONNECT TO EXITING 4" STEAM VTR. PROVIDE 4" STEAM LINE WITH ISOLATION VALVE SHEET CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT-OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN COMPUTER ROOM COOLING UNIT # /FLR, BOTTOM LINE INDICATES LOCATION NOTES SCE DRAWINGS 13 2M60 2M62 2M63 0 0 0 8' 4' 0 4' 8' 16' SCALE: 1 /8 " =1' --Q" CURRENT REVISION JOB NO. DWG NO. 2M61 150680 --01 SYMBOL R I G 9- 90 -2M61 RECarb CITY OF T APR 0 9 2007 DATE 04.05.07 COMP NO. tr I I 'r I I: • 1 • . I i, r; `•I ORIG 9 -90 RENOVATION J#150680 -01 COFFMAN M. SOTURA 04,05.07 EIIGIAEER OPEN OFFICE 1 21M8 OPEN OFFICE 21S8 OFFICE 23L10 OFFICE 22L10 BY APPROVED DATE SYM WORK ROOM 21L10 1 23L9 OFFICE OFFICE 22L9 REVISION CONFERENCE 21L9 3 "CHWS & CHWR Wt... L "MPS BY APPROVED DATE - 1 V C I \ !! CONF ENCE� ,J' 1 \ 1 1!! l !! 1 x ! 1 1 1 / EQUIP. 21 7 7 "MPS —1/2 6 "CHWS & CHWR •f 6 "MPS t t I t SECOND FLOOR HVAC PIPING PLAN CONFERENCE 22L3 3" LPC DN OFFICE 21M4 OFFICE 21 N4 3" LPC UP CONFERENCE 2 1P3 [mum IRO i /10/O9 WORK ROOM 21L3 OPEN OFFICE 21R5 1 OPEN OFFICE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION I5 APPROVED DRAWN COFFMAN CHECKED M. SOTURA APPROVED APPROVED ISSUE FOR PERMIT DATE 01.15.07 01.15.07 SUBTITLE TILE MECHANICAL MASTER N FF G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 SECOND FLOOR HVAC PIPING PLAN 9 -90 RENVATION BUILDING 9 -90.2 COL. L— S/1 -13 DEV. CENTER,WA LEGEND PC - LPC - MPC MPS — CHWS— CHWR va 0I cI E AC1\ K8 ii GENERAL NOTES CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT—OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN NOT USED CONSTRUCTIO\ COMPUTER ROOM COOLING UNIT # /FLR, BOTTOM LINE INDICATES LOCATION � STEAM TRAP REFERENCE DRAWINGS NOTES PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1 —1 /2" ISOLATION VALVES (TYPICAL). LOCATE IN ACCESSIBLE LOCATION. PROVIDE NEW 3" LOW PRESSURE STEAM CONDENSATE. PROVIDE NEW STEAM TRAP PROVIDE NEW INSULATION FOR EXISTING 6" STEAM PIPE. SHEET JOB NO. 73 0 2M60 2M60 2M 61 jM62 / j 2M63 0 0 0 KEY PLAN SCALE: NONE 8 DWG NO. 4 0 4' SCALE: 1/8"=1 CURRENT REVISION 8' " 2M62 150680 -01 9-90-2M62 TV T� Ci LA APR 0 9 2007 PERrizIT' Carts I �:, 16' G DATE 04.05.07 COMP NO. r 1 i • a I ' 'rti, J'I '= 1 a1 ' C[ -1 1 • 9 -90 RENOVATION FE ft REVISION HUDDLE J #150680 -01 COFFMAN OPEN OFFICE OFFICE 23T10 OFFICE 22T1 O APPROVED M. SOTURA WORK ROOM OPp+ N OFFICE 21 U8 DATE SYM 04.05.07 OFFIC OFFICE REVISION CONFEREN WOMEN CONFERENCE 6 " MPS DN 3" STM V UP&DN CONFERENCE CHWR 1 _ 1/2" STAIR APPROVED 3 "CHWS & CHWR NFERENCE AF ArAfAW® CONFERENCE 21W5 SECOND FLOOR HVAC PIPING REMOVAL PLAN OFFICE OFFICE .\\ I EXPIRES 1 /10 /09 WORK ROOM APPROVED BY OFFICE OFFICE ._ __ _ .■m/ _ _ ,.. ._ 11 _ _. ACCEPTAB This DESIGN AND /OR SPECIFICATION IS APPROVED OPEN OFFICE 21T5 DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED HUDDLE ISSUE FOR PERMIT DATE 01.15.07 01.15.07 MECHANICAL MASTER SECOND FLOOR HVAC PIPING PLAN 9-90 RENOVATION BUILDING 9 -99.2 N FFAN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 LEGEND PC LPC MPC MPS CHWS CHWR FERAL REFERENCE DRAWINGS CONSTRUCTION PROVIDE CHILLED WATER SUPPLY AND RETURN LOOP. PROVIDE 1 ISOLATION VALVES (TYPICAL). PROVIDE INSULATION FOR EXISTING 6" STEAM PIPES. JOB NO. /F DWG NO. KEY PLAN SCALE: NONE 8' 4' 0 COMPUTER ROOM COOLING UNIT # /FLR, BOTTOM LINE INDICATES LOCATION D OTES CONDENSATE RETURN (PUMPED) LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CHILLED WATER SUPPLY CHILLED WATER RETURN SHUT—OFF VALVE CAP PIPE TURNING UP PIPE TURNING DOWN CURRENT REVISION COTES SYMBOLQ R IC 150680 -01 9-90-2M63 COMP NO. 04.05.07 r. - . ,l • ,• $. 8 "F SEE 1 M 11 O & 1M260 FOR CONTINUATION OF PIPING 3 "V UP 3 "V DN 1-1/4"C DN TO DRAIN 1"60# MPS 5 F — � a EXISTING 8" FIRE SPRINKLER ALARM VALVE 1 -1/2"PRV OVER 3 "PRV, SEE 1/M313 3/4" 125# MPC 3 "V DN 1" 4 "W DN 6" HUB DRAIN (E) FLOOR DRAIN - MECH. 1ST FLOOR V SCALE: 1/2"= 1' -0" (E)8 " F 1106 ECH r 3/4 "A t � 16x16 /13F 71B OVER /BF I A SEE 1/M31 1 106 ( 1M3, 1M11, 1M61 1M452 4 "- t S 14x14 SOUNDLINED 41PC TRANSER BOOT, SEE 1/M506 SYM ORIG 9 -90 RENOVATION J #150680 -01 COFFMAN M. SOTURA 04.05.07 6 "HUB DRAIN REVISION 1 ST FLOOR SCALE: 1/2"= 1' -0" V1ECH APPROVED DATE SYM 12J6 1M3, 1M11, 1M61 1M452 / 14x12 EXHAUST DUCT REVISION 18x14 BY APPROVED DATE 3 "V UP 2-1/2" LANDSCAPE DOUBLE CHECK VALVE BPI y6 I A 3/4 "A DN TO PIT W /HOSE END VLAVE & DIRT LEG ± 36" ABOVE FLOOR 5" DUCT (20 GA.) DN TO 4' ABOVE PIT FLOOR LEVEL W /MESH SCREEN AT BOTTOM WITH 14"0 EXHAUST DUCT FROM SHAFT ABOVE 6" MPS UP TO 2ND FLOOR WITH NEW SHUTOFF VALVE AND 2" BY -PASS. SEE DETAIL M508 6 "STEAM 125# MPS (BELOW SLAB) I I 3 “PUMPED CONDENSED (BELOW SLAB) —' 1 "COMPRESSED AIR (BELOW SLAB) ArifflarAf” ® 1 ST FLOOR SCALE: 1/2"= 1' -0 v1ECH - 11V6 ( UGM3, 1M3, 1M13, 1M63 1M452 REPLACE SUMP PUMP 4" WASTE FROM MH #2 EL 6.25' 'WIRES 1/10/09 APPROVED BY CCEPTABILITY THIS DESIGN AND /OR SPECIFICATION 1S APPROVED DEPT. AUTOMATIC WET FIRE SPRINKLER ALARM VALVE (EXIST) 3/4 "A UP WALL GRILLE 1 SX16 DATE 16x16 CEILING MOUNTED SUvP PUMP PLA - SUMP PUMP, SEE 4/1M452 PRV -3, SEE DETAIL 2/M509 1 "STM VENT UP TO ROOF 3 "STM VENT UP TO ROOF DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED 4# LEAD FLASHING 12" ALL AROUND SLEEVE m$L F lee-- 4"W ( 1M452 2 "CHECK VALVE DATE 01.15.07 01.15.07 SUBTITLE TITLE 2 "W (GALV PIPE) IN ZURN Z-195--3 FLASHING SLEEVE ISSUE FOR PERMIT MECHANICAL MASTER 9 -90 RENOVATION BUILDING 9x9O.1 hOFFMAN f &S N GIN E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 ENLARGED MECHANICAL ROOM PLANS LEGEND A C - CW - -CW— F F - LPC MPC— MPS PC PW V W GE W 0 4 i 0 STEAM CONDENSATE EQUIPMENT IS IN A 7' DEEP PIT. PIT IS 67 "x73" WITH A FLOOR GRILLE ON TOP. REFERENCE DRAWINGS UGM3, COMPOSITE UNDERGROUND PLUMBING PLAN 1M3, COMPOSITE FIRST FLOOR PLUMBING PLAN M314, PLUMBING DIAGRAMS 1M61, FIRST FLOOR HVAC PIPING PLAN 1M63, FIRST FLOOR HVAC PIPING PLAN CONSTRUCTION NOTES REPLACE FLOW AND TAMPER SWITCHES. CONTRACTOR SHALL INSTALL SWITCHES PROVIDED BY "ADT ". PROVIDE A SHUTOFF VALVE WITH BYPASS FOR THE 6 "MPS RISER. PROVIDE NEW 2 -1/2" PUMPED CONDENSATE PIPE CONNECT TO UNDERGROUND 3" PUMPED CONDENSATE PROVIDE STEAM CONDENSATE PUMP PACKAGE PROVIDE NEW 2" CHECK VALVE PROVIDE 1" 60 PSI STEAM PROVIDE STEAM VENT PROVIDE TEMPORARY CONNECTION TO SANITARY SEWER UNTIL WASTE CONNECTION IS COMPLETE, SEE UGM3. INSTALL VD BETWEEN GRILLE AND 5" DUCT DEV. CENTER,WA COMPRESSED AIR. PLANT CONDENSATE RETURN (GRAVITY) DOMESTIC COLD WATER DOMESTIC COLD WATER BELOW GRADE FIRE LINE FIRE LINE, BELOW GRADE OR FLOOR LOW PRESSURE CONDENSATE MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM CONDENSATE RETURN (PUMPED) PROCESS WATER VENT WASTE WASTE BELOW GRADE VENT THROUGH ROOF PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW TURNED DOWN OR AWAY POINT OF CONNECTION RETURN OR EXHAUST AIR FLOW DIRECTION STEAM TRAP BALL VALVE WITH HOSE END F- VD (VOLUME DAMPER) ERAL NOTES © O1 0 13 0 0 0 CURRENT REVISION SHEET JOB NO. DWG NO. 1 M452 150680 -01 SYMBOL 9-90-1M452 DATE 03.30.07 COMP NO. RECEIVED CITY OF 11 Ifr 0, A 'APR 0 9 2001 PERMIT CEiu w. • • • _ ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION 5 APPROVED DRAWN AN DATE 15.07 CHECKED M. SOTURA 01.15.07 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED OPP. HAND P1M450 M500 MECH ROOM EXHAUST Eat>.. MAN BAR (TYP) TOILET EXHAUST 36/42 TRANSITION DN TO 28/36 AT FLOOR - Ox32 DN TO 28x36 MAN BAR (TYP) 48x48 TRANSITION TO 42x45 (2 TYP) FLEY, (TYP) 2-1/2"LPS - ►+ FLEX rQ 96/96 SOUND ATTENUATOR 72x72x60 6 "CHWR DN 6 "CHWS DN SOUND ATTENUATOR 96x96x54 6 "CHWR VFD _ VFD CONDENSATE PUMP TRAP PACKAGE, SEE DETAIL 5/509 (TYP) 4 "LPC DN -- 1500 CF 24x18 96 "x48 "x36" AIR BLENDER - NEW PLENUM WALL 24/18 BOD AT 9'AFF COR - 30 "x60 "DOOR FIRE DAMPER — D> 1500 CFM 24 "x18" MOIDRIZED DAMPER EXHAUST AIR DAMPER MOTOR OPER 10'- 0 "x2' -6" CURB ALL AROUND N ` - ' AIR TIGHT SIDING 24x16 GRILLE. EXHAUST LOUVER 30 "Wx24 "H EXHAUST LOUVER 4'-- O "x5' -O" 2 "LPC TCP -1 AIR TIGHT SIDING ANCHOR UP ENLARGED WEST PENTHOUSE HVAC PLAN SCALE: 1/4":= r-0" AV E /NG 8 "CHWS 6" STEAM RELIEF UP THRU ROOF, SEE DETAIL 8/509 8 "CHWR EXISTING CURB SYM ORIG 9 - 90 RENOVATION REVISION J #150680 -01 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 STEAM METER, SEE DETAIL 7/509 NEW INSULATED PLENWM � ' ' \ OPP. HAND P1M450 M500 PIPE SUPPORT 5 "LPS PROVIDE SMOKE DAMPER INSTILL PUMP TRAP PACKAGE PROV DE 72x72 SOUND ATTEI1IUATOR (60" LONG) PROVIDE 48x96x110 PLENUM WITH 48x48 TRANSITION TO 42x45 DUCT NEAR FLOOR PROVIDE 40x32 DN, TRANSITION TO 28x36 DUCT NEAR FLOOR PROVIDE 96x96 SOUND ATTENUATOR (54" LONG) INSTALL FLOW MEASURING STATION OP- 4 "- 125 "MPS - EXHAUST AIR PROVIDE NEW STEAM PRESSURE REDUCING STATION PROVIDE NEW FIRE DA PER PROVIDE NEW MOTORIZ D DAMPER PROVIDE TEMPERATURE SENSOR FOR PENTHOUSE LOCATE FLOOR DRAIN NEAR COOLING COIL OUTLET, SEE P 1 M PROVIDE 2" FIBER GLASS ACCOUSTICAL LINER WITH MYLAR ENCAPSULATION & PERFORATED GALVANIZER © PLENUM INSTALL EXISTING MAN BARS ISSUE FOR PERMIT SUBTITLE TITLE MECHANICAL MASTER EXHAUST AIR LOUVER 10'- 0 "x5' -0" BY BUILDER /SEE RFM3 & P1M451 FOR .c .--- CONTINUATION EXHAUST AIR DUCT ABOVE 1O O ', X2 ,_ 6 " SUPPORT ANGLE FOR INCLINED PLENUM WALL NON AIR TIGHT SIDING CLEAN RETURN FAN PROVIDE PIPE SUPPORT N FFiAN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 206 623 0717 Fax 206 624 3775 9 -90 RENOVATION BUILDING 9 -901P1 COL. F -K/5 -9 EXTEND EXISTING CHILLED WATER SUPPLY AND RETURN INSTALL NEW AIR HANDLER UNITS, AHU -1 & AHU -2 PROVIDE NEW BLENDER IN MIXING AIR PLENUM. (INSTALL LOW ENOUGH FOR ACTUATOR) NEW VFD DRIVE BY EC. KEEP EXISTING MOTOR, CHANGE BELTS, CHANGE SHEAVES TO PROVIDE 420 RPM MAX FAN SPEED AT MOTOR FULL SPEED PROVIDE NEW 4'x6' OUTSIDE AIR DAMPERS WITH ACTUATORS, LOCATE ALL ACTUATORS INSIDE MIXING PLENUM REMOVE EXISTING DAMPERS & PROVIDE NEW 3'x8' RETURN AIR DAMPERS WITH ACTUATORS, LOCATE ALL ACTUATORS INSIDE MIXING PLENUM SEAL MIXED AIR PLENUM AROUND AIR HANDLER UNITS AND GAP BETWEEN THEM. PROVIDE 2" INSULATION. PROVIDE 1-1/4" COOLING COIL DRAIN CLEAN EXHAUST AIR LOUVER & MESH SCREEN ENLARGED WEST PENTHOUSE HVAC PLAN E PC LPC LPS HWS HWR D D TCP TEMPERATURE CONTROL PANEL FD I SD fBDD DM CONDENSATE RETURN (PUMPED) CONDENSATE, STEAM (LOW PRESSURE) LOW PRESSURE STEAM (15 PSI) CHILLED WATER SUPPLY CHILLED WATER RETURN POINT OF CONNECTION SMOKE DETECTOR MOTOR FIRE DAMPER SMOKE DAMPER BACK DRAFT DAMPER MOTORIZED DAMPER O TEMPERATURE SENSOR ATMD AIRFLOW & TEMPERATURE MEASURING ~ DEVICE (ATMD) NERAL OTES RATURE CONTROL PANEL. 2 @ 30 "x36" ERENCE DRAWINGS PLUMBING DIAGRAM PENTHOUSE SECTION AIR HANDLING UNIT DETAILS STRUCTION NOTES 4x18 DUCT. DO NOT INSULATE E EXISTING OUTSIDE AIR DAMPER AND PENING E NEW EXHAUST FAN & CONNECT STING DUCTWORK FOR EF -1 AND TO UCTWORK FOR EF-3 ON 13 P1M450 0 0 0 0 0 0 KEY PLAN SCALE: NONE 4' 2' 0 SCALE: 1/4"= 0" CURRENT REVISION "'OM w � P1M450 JOB NO. 150680 -01 Ili tr cF rI wtA APR 0 9 2007 CEw DATE 04.05.07 COMP NO. LEG C GE TEMPE RE F M312, M500, M510, CO C NEW 2 DN LOUVERS 10'- O "x5' -O" PROVIDE STEAM METER PROVIDE 2" RIGID BOARD INSULATI & GALVANIZED SHEET METAL PLENUM CONNECT NEW 8" CHWS &R PIPE TO EXISTING CHILLED WATER LOOP ON ROOF. PROVIDE SHUT OFF VALVES REMOV CAP 0 SMOKE DETECTOR BY ELECTRICAL CONTRACTOR (TYPICAL) PROVIDE NEW LOW PRESSURE STEAM LINE PROVID TO EXI NEW D DEV. CENTER,WA DWG ND. 9- 90- P1M450 r I' ' I. !� 3 ,1 IT EXHAUST AIR LOUVER 10'- 0 "x5' -0" BY BUILDER SEE RFM3 & P1 M450 FOR CONTINUATION EXHAUST AIR DUCT (OVER) SUPPORT ANGLE FOR INCLINED PLENUM WALL NON AIR TIGHT SIDING EXHAUST AIR LOUVERS 10'- 0 -0" OPENING IN FLOC) FOR RETURN AIR - CURB ALL AROUND EXHAUST AIR DAMPER MOTOR OPER 10' -0 "x2 EXHAUST AIR DAMPER ( MOTOR OPER 10'- 0 "x2' --6" -FAN R-14 24/18 BOD AT 19'AFF �- 24 "x48 "DOOR ' I 30 "x60 "DOOR --- FIRE DAMPER 96 "x48 "x36' AIR BLENDER SEAL PLENUM ABOVE UNIT - /FLEX NEW PLENUM WALL - 1500 CFM '�-- 24x18 13 /4 "LPS "LPS - 4 "LPS 1 "PC 4 "LPS STEP (OVER PIPING) �- AIR TIGHT SIDING — — *la _ w .Tmm v erg{ 5 "CHWR SOUND ATTENUATOR 96x96x60 4 ‘ 6 4. 1 . 4 , D APMFAirAfiff® SOUND ATTENUATOR 72x72x60 ENLARGED EAST PENTHOUSE HVAC PLAN SCALE: 1/4".= _ 1' -0" eons 1/10/09 40x32 DN TO 28x36 MAN BAR (TYP) 48x48 TRANSITION TO 42x45 (2 TT) BY I APPROVED DATE COFFMAN M. SOTURA 1 04.05.07 REVISION APPROVED FLEX (TYP) EXHAUST LOUVER 4 ' -0 " APPROVED BY 24x16 GRILLE NON AIRTIGHT SIDING 36/42 TRANSITION DN TO (E)28/36 AT FLOOR INSTALL PUMP TRAP PACKAGE PROVIDE 72x72 SOUND ATTENUATOR (60" LONG) PROVIDE 48x96x110 PLENUM WITH 48x48 TRANSITION TO 42x45 DUCT NEAR FLOOR PROVIDE 40x32 DN, TRANSITION TO 28x36 DUCT NEAR FLOOR PROVIDE 96x96 SOUND ATTENUATOR (54" LONG) PROVIDE AIR FLOW MEASURING STATION ACCEPTABILITY THIS DESIGN AND /OR PECIFICATION IS APPROVED ISSUE FOR PERMIT DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTITLE u P1M451 M500 �> NEW LOUVER BY GC D>. PROVIDE NEW FIRE DAMPER V::> PROVIDE NEW MOTORIZED DAMPER PROVIDE TEMPERATURE SENSOR FOR PENTHOUSE LOCATE FLOOR DRAIN NEAR COOLING COIL OUTLET, SEE P1 M453 PROVIDE 2" FIBER GLASS ACCOUSTICAL LINER WITH MYLAR ENCAPSULATION & PERFORATED GALVANIZED SHEET METAL © PLENUM REUSE EXISTING MAN BARS PROVIDE 2" BOARD INSULATION PROVIDE 2" RIGID BOARD INSULATION & GALVANIZED SHEET METAL © PLENUM 331: CLEAN RETURN FAN N FFAN G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 PROVIDE 1 -1/4" COOLING COIL DRAIN. LOCATE WITHIN 1 FOOT OF DRAIN OUTLET. DO NOT LOCATE IN FRONT OF ANY DOOR. CLEAN EXHAUST AIR LOUVER MESH SCREEN 10 NEW 24x18 DUCT ENLARGED EAST PENTHOUSE HVAC PLAN LEGEND PC CONDENSATE RETURN (PUMPED) LPC CONDENSATE, STEAM (LOW PRESSURE) LPS LOW PRESSURE STEAM (15 PSI) - CHWS CHILLED WATER SUPPLY - CHWR CHILLED WATER RETURN -- POINT OF CONNECTION D SMOKE DETECTOR n MOTOR TCP TEMPERATURE CONTROL PANEL I FD 1 i SD 1 1BDD 1 DIM 1 MOTORIZED DAMPER 0 TEMPERATURE SENSOR ATMD H AIRFLOW & TEMPERATURE MEASURING DEVICE (ATMD) GENERAL \OTES TEMPERATURE CONTROL PANEL. 2 © 30 "x36" REFERENCE DRAWINGS M312, PLUMBING DIAGRAM M500, PENTHOUSE SECTION M510A, NR HANDLING UNIT DETAILS COUSTRUCTION NOTES EXTEND EXISTING CHILLED WATER SUPPLY AND RETURN INSTALL NEW AIR HANDLER UNITS, AHU -1 & AHU -2 ON CURB (SEE ARCH FOR CONCRETE) PROVIDE NEW BLENDER IN MIXING AIR PLENUM NEW VFD DRIVE BY EC. KEEP EXISTING MOTOR, CHANGE BELTS, CHANGE SHEAVES TO PROVIDE 420 RPM MAX FAN SPEED AT MOTOR FULL SPEED PROVIDE NEW 4'x6' OUTSIDE AIR DAMPERS WITH ACTUATORS, LOCATE ALL ACTUATORS INSIDE MIXING PLENUM REMOVE EXISTING DAMPERS & PROVIDE NEW 3'x8' RETURN AIR DAMPERS WITH ACTUATORS SEAL MIXED AIR PLENUM AROUND AIR HANDLER UNITS AND GAP BETWEEN THEM REMOVE EXISTING OUTSIDE AIR DAMPER AND CAP OPENING SMOKE DETECTOR BY ELECTRICAL CONTRACTOR (TYPICAL) PROVIDE NEW LOW PRESSURE STEAM LINE PROVIDE NEW EXHAUST FANS & CONNECT TO EXISTING DUCTWORK FOR EF -2, TO NEW DUCTWORK FOR EF -3 PROVIDE SMOKE DAMPER 4' 2' 0 2' 4' SCALE: 1/4"=1'-0" CURRENT REVISION P1M451 KEY PLAN SCALE NONE P1M451 FIRE DAMPER SMOKE DAMPER BACK DRAFT DAMPER SYMBOLG COMP NO, 04.05.07 MECHANICAL MASTER 9-90 RENOVATION BUILDING 9 -90.P1 COL. N -T /5 -9 DEV. CENTER,WA DWG NO. 9-90-P1M451 • 1. '41 t i < u c r c C c 0 SYM 2"RD 1 2"RD-1 s 2"RD-1 8" 4"RD-1 REVISION 3-v-rR5 Ow- BY 4 RD-1 2"VTR 3"VTR 2uvril 2"VTR CHWS CHWR 3"VTR APPROVED DATE SYM 1 WEST PENTHOUSE ROOF REVISION OUTSIDE AIR INTAKE 4"RD-1 6" STEAM SAFETY VAL-VER-ELEF VENT 4" STEAM VENT 1 BY 1, APPROVED DATE - 5-0" 4"RD-1-I 4"RD-1 ORIG 9-90 RENOVATION 4150680-01 COFFMAN M. SOTURA 04.05.07 I 1 It ® _RIPE _SUPPORT (TYP) ' ANCHO OUTSIDE AIR INTAKE COMPOSITE ROOF MECHANICAL PLAN SCALE: 1 /16"= 1 —0" 3"RD-1 EAST PENTHOUSE] ROOF 8" 2"VTR 4"RD-1 I2-1/2"VTR ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY MR) DEPT. DATE CHWS CHWR 3"VTR MECH ROOM EXHAUST FAN DRAWN COFFMAN CHECKED M. SOTURA 'MINER CKED APPRO VE APPROVED 1 1 DATE 01.15.07 01.15.07 SUBTITLE TT ISSUE FOR PERMIT BRIDGE TO 9-101 3"RD-2, SEE 1M113 FOR PIPE RISER CANOPY ROOF 9-90 RENOVATION BUILDING 9-90.RF MECHANICAL MASTER COL. A-Y/1-13 AcOFFMAN NGINEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 981 01 —1625 206 623 0717 Fox 206 624 3775 COMPOSITE ROOF MECHANICAL PLAN DEV. CENTER,WA LEGEND CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN LPS — LOW PRESSURE STEAM (15 PSI) X PIPE ANCHOR PIPE GUIDE ROOF DRAIN 0 VENT THRU ROOF GENERAL NOTES REFERENCE DRAWINGS CO \ISTRUCTION NOTES INSTALL NEW ROOF DRAIN PROVIDE NEW STEAM PIPE PROVIDE SUPPORT FOR NEW STEAM PIPE. SEE STRUCTURAL DRAWINGS FOR TYPICAL ATTACHMENT TO STRUCTURE AND ROOF FLASHING DETAIL ON ARCHITECTURE DRAWINGS CLEAN OUTDOOR AIR INTAKE PROVIDE NEW 3" STEAM VENT. EXTEND TO 5 FEET ABOVE ROOF PROVIDE NEW 1" STEAM VENT. EXTEND TO 5" ABOVE ROOF SEE DRAWING P1M450 FOR CONTINUATION PROVIDE PENETRATION THROUGH ROOF FOR STEAM VENT PROVIDE NEW EXHAUST FAN SHEET ei o eo 0 0 NI - INN k LRFM3 JOB NO. DWG NO. net • s CITY OF Tt Itc4,4 ttlA KEY PLAN 4 APR 0 9 MI SCALE: NONE PERMIT (.1E% 16' 8' 0 8 16' 32' SCALE: 1/16"=1'-0" CURRENT REVISION RFM3 'ORIG 150660-01 9-90-RFM3 DATE 04.05.07 COMP NO. 9 -90 RENOVATION COLD DECK SMOKE DAMPER REVISION AIR HA SCALE: NONE HOT COLD *: FOR CONF * * *: FOR ROOM VAV DUAL SCALE: NONE RA DATA AND CO SCALE: NONE TO FIRE ALARM & HARDWIRED TO FANS D PT6 SMOKE DAMPER VDLING U SUPPLY TERMINAL UNIT J #150680.01 HOT DECK vir TO FIRE ALAR HARWIRED TO CHILLED WATER CHILLED WATER COIL vIPUTER R00 BY COFFMAN APPROVED M. SOTURA VARICONE DAMPERS V SUPPLY FANS DATE 04.05.07 FANS ED ON DRAWINGS SORS (SEE ELECTRICAL DRAWINGS) AL UN A VFD SYM TT5 ITS COOLING SA CHILLED M WATER SUPPLY FAN M310 *: ONLY FOR AC1K8, AC1 E10, AC1 F10, ACI H7 s C•OLINC u dM310 REVISION HEATING COIL VFD r-t STEAM COLD DECK (AHU -1& AHU -3) HOT DECK OAHU -2& AHU -4) HEATING COIL a ■ STEAM COLD BY SUPPLY TERMINAL UNIT VAV SINGLE DUCT TERMI\ SCALE: NONE EXHAUST FAIL SCALE: NONE APPROVED DATE E LOUVER (TYP) OA <4 V FT6 �"/ Q(3 DAMPERS) (1) ECOMOMIZER DAMPERS (2 DAMPERS) COVTR L DIAGRAM (AHU -1 & —3 AND AHU -2 & —4 AND RETURN FANS b Q ?/ Q� ERENCE ROOMS AS NO S WITH OCCUPANCY SE DUCT TERMIN AL U Jt3 ' 0 SA EF -1 & EF -2 � ,19,o BOE /NOS TO PENTHOUSE VFD 1 VFD RETURN FANS 2 DAMPERS) E> D EXPIRES 1/10/09 EA RA TO FIRE ALARM & HARDWIgED TO FANS (TYP) AIRFLOW MAX. HOT DECK MIN. COLD DECK 0.4 CFM /SQ. FT. UNOCCU. COLD DECK 0.2 CFM /SQ. FT. DUAL DUCT AIRFLOW DIAGRAM SCALE: NONE M310 SCALE: NONE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE ROOM TEMPERATURE INCREASE >w DRAWN COFFMAN 'MOM SIMMER CHECKED APPROVED APPROVED TO FAS (2) AT 1ST FLR STAIRS (1) AT FIRST FLR SHAFT HEATING COOLING DATE SUBTITLE 01.15.07 01.15.07 TITLE EXHAUST FANS EF -3 & EF-4(7 J.!t3 10 ISSUE FOR PERMIT MECHANICAL MASTER MAX. COOLING AIRFLOW 9 -90 RENOVATION BUILDING 9 -90 OFFMAN A6 1 f N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 --1625 206 623 0717 Fax 206 624 3775 CONTROL DIAGRAMS LEGEND D VFD FAN ELECTRIC MOTORIZED CONTROL VALVE -\-- ELECTRIC MOTORIZED DAMPER WITH END SWITCH AIRFLOW DIRECTION FAS FIRE ALARM SYSTEM r > EA REFERENCES M311, SEQUENCES OF OPERATION DEV. CENTER,WA CURRENT REVISION SHEET TEMPERATURE TRANSMITTER ROOM TEMPERATURE SENSOR PRESSURE TRANSMITTER AIRFLOW TRANSMITTER VIBRATION TRANSMITTER CURRENT SENSOR FREEZE STAT HUMIDITY TRANSMITTER CARBON DIOXYDE TRANSMITTER OCCUPANCY SENSORS MOTOR SMOKE DETECTOR (BY ELECTRICAL) JOB NO. DWG NO. VARIABLE FREQUENCY DRIVE WITH FAN START /STOP, FAN RPM OUTPUT AND FEED BACK M310 'ORE 150680 -01 9-- 90 -M310 RECEIVED cr1 OF TUKWILA APR 0 9 2007 DATE 04.05.07 COMP NO. SYM REVISION SEQUE CES OF OPERATION GENERAL FUNCTIONAL REQUIREMENTS A. CONTROL OF EQUIPMENT AS SEQUENCE OF OPERATIONS 1. TIME AND HOLIDAY SCHEI1 ULES DESCRIBED IN THE HALL INCLUDE: 2. OPTIMUM START CONTRO� AS PER WASHINGTON ENERGY CO E 1412.4.2 3. ALARM LIMITS AND HISTORIES 4. SUMMARY OF DATA FOR 1 CH ZONE 5. TREND LOGS AND HISTO ICAL DATA 6. ALL SETPOINTS 7. MASTER MENU 8. DYNAMIC COLOR GRAPHIC INTERFACE B. THE FOLLOWING POINTS DE•CRIPTIONS AND SEQUENCES OF OPERATION . HALL BE ENHANCED AS NECESSARY AND INCLUD D AS PART OF THE CONTROL DRAWINGS TO EXP 1 ND AND CLARIFY INFORMATION SHOWN ON TH DRAWINGS. 1. POINTS INFORMATION SHA L BE DISPLAYED AND ORGANIZED BY SYSTEM I DYNAMIC GRAPHIC FORM AT THE OPERATOR STATIONS. 2. IT SHALL BE POSSIBLE T I "DISCONNECT" ANY OUTPUT OR SETPOINT FR M THE AUTOMATIC CONTROL LOGIC AND ENT R A MANUAL OR STATE FROM ANY OPERA 1DR STATION. 3.1T SHALL BE POSSIBLE T WITH A MANUAL VALUE F STATION. C. THE FOLLOWING COMMANDS SHALL BE AVAILABLE AT TH REPLACE ANY INPUT OM ANY OPERATOR 4. ALL CONTROL LOOP PARAMETERS FOR EACH LOOP SHALL BE DISPLAYED ON ONE DISPLAY. DISPLAY AND DATA OPERATOR STATION: 1. AIR HANDLING UNIT A. FANS STATUS (CURRE T SENSOR SWITCH) B. OUTSIDE AIR TEMPERA URE C. MIXED AIR TEMPERATU E D. SUPPLY AIR TEMPERAT RE E. RETURN AIR TEMPERAT RE F. COLDEST AND WARMES ZONE, ALL ZONES SAMPLED G. DUCT STATIC PRESSUR (AVERAGING 2 SENSORS) H. ALARMS (TEMPERATUR =, AIRFLOW, PRESSURE, FILTER) D. THE FOLLOWING POINTS AR REQUIRED BY CONTROL STRATEGY: 1. DIRECTLY MEASURED TOT L SUPPLY AIRFLOW (CFM) 2. DIRECTLY MEASURED TOT L RETURN AIRFLOW (CFM) 3. DIRECTLY MEASURED TOTAL OUTSIDE AIRFLOW (CFM) E. THE FOLLOWING POINTS SHALL BE DISPLAYED USING CALCULATED VALUES BASED UPON COMMAND POSITION UNLESS EXACT VALUES, AS INDICATED BY A FEEDBACK SIGNAL, ARE REQUIRED BY CONTROL STRATEGY: 1. FAN SPEED (PERCENT OF FULL SPEED) 2. DAMPER POSITIONS (PERCENT OF FULL OPEN) SYM REVISION F. AIR TERMINALS 1. CURRENT SPACE TEMPERATURE 2. OCCUPIED HEATING /COOLING SEPOINT 3. UNOCCUPIED HEATING /COOLING SETPOINTS 4. CURRENT STATUS (HEATING /COOLING) 5. CURRENT MODE (DAY /NIGHT) 6. MINIMUM AND MAXIMUM AIRFLOW SETTING (CFM) 7. COLD DECK AIRFLOW READING (CFM) 8. HOT DECK AIRFLOW READING (CFM) 9. DISCHARGE AIR TEMPERATURE READING 10. HIGH /LOW TEMPERATURE ALARM AIR HANDLING UNITS AHU -1, AHU -2, AHU-3 & AHU -4 A. START-STOP AND FAN SAFETIES: 1. SAFETY FEATURES: THE FOLLOWING SHALL PREVENT FAN OPERATION UNDER ANY MANUAL, BY -PASS. THESE SAFETIES SHALL BE HARD -WIRED AND HAVE A MANUAL RESET. A. DIVISION 26 FIRE ALARM OUTPUT. B. HIGH PRESSURE CUTOUT PRESSURE SWITCH PT1 OR PT6. COLD DECK FREEZESTAT (FREEZE PROTECTION). C. D. DISCHARGE AIR AND RETURN AIR DUCT-MOUNTED SMOKE DETECTORS WILL BE PROVIDED BY DIVISION 28. THE DETECTORS WILL COMMUNICATE WITH THE DIVISION 26 ARE ALARM SYSTEM. AN OUTPUT MODULE WILL BE PROVIDED UNDER DIVISION 26 (IN THE GENERAL VICINITY OF THE VFD), WHICH WILL PROVIDE FIRE ALARM CONTROL OUTPUT FOR THE AIR HANDLER. DDC CONTROL SHALL REPORT SMOKE DETECTORS STATUS. 3. ACTION - NORMAL OPERATION: A. IF THE VFD CONTROL SWITCH IS IN "AUTO" AND THE EMCS IS SET TO ALLOW OPERATION OR IF THE VFD CONTROL SWITCH IS IN "ON" POSITION; THEN RETURN AIR DAMPERS, MINIMUM OUTSIDE AIR DAMPER AND EXHAUST AIR DAMPERS SHALL START OPENING; DAMPERS SHALL MODULATE ACCORDING TO SUPPLY AND OUTSIDE AIRFLOW REQUIRED IN THE BUILDING. WHEN RETURN AIR DAMPERS ARE PROVEN OOPEN AND IF SAFETIES ALLOW OPERATION; THEN START THE SUPPLY AND RETURN FANS. THE FANS SHALL RAMP UP TO AND OPERATE AT THE COMMANDED SPEED (SEE BELOW). IF ANY OF THE ABOVE CONDITIONS CHANGE, THEN THE FANS SHALL STOP OPERATING. 4. ACTION -- SUPPLY FANS SPEED CONTROL: A. SUPPLY FANS SHALL OPERATE AT THE SPEED COMMANDED BY THE STATIC PRESSURE SENSORS (TWO PER AIR HANDLER) LOCATED IN THE AIR DISTRIBUTION SYSTEM, EXCEPT, THE FANS SHALL NOT BE ALLOWED TO MOVE MORE THAN 105% OF THE "DESIGN" CFM THROUGH THE UNIT AS MEASURED AT FT1, FT2 & FT3. THE STATIC PRESSURE SETPOINT SHALL BE RESET BASED ON THE TOTAL SUPPLY AIRFLOW OF EACH HOT DECK AND COLD DECK. THE SETPONT WILL BE 0.80" AT MINIMUM CFM AND 1.5" AT MAXIMUM CFM AND BE VERIFIED BY THE BALANCING CONTRACTOR. 5. ACTION - RETURN FANS SPEED CONTROL: A. RETURN FANS SHALL OPERATE AT THE SPEED COMMANDED BY THE SUPPLY AIR FANS, EXCEPT THE FANS SHALL NOT BE ALLOWED TO MOVE MORE THAN 105% OF THE "DESIGN" CFM AS MEASURED AT FT4 AND FT5. THE RETURN FANS CFM SHALL BE EQUAL TO THE SUPPLY CFM MINUS EXHAUST FANS EF -1, EF -2 & EF -3 CFM. THE BUILDING SHALL BE PRESSURIZED SLIGHTLY POSITIVELY. ORIG 9-90 RENOVATION BY APPROVED , DATE J #150680 - 01 COFFMAN M.SOTURA 04.05.07 BY APPROVED DATE 6. ACTION - FAN SHUTDOWN AND ISOLATION: 1. A. A. C. B. IF THE HIGH PRESSURE CUTOUT PRESSURE SWITCH PT1 OR PT6 ACTIVATES, THE EMCS SHALL COMMAND THE UNIT TO SHUT DOWN AND HAVE A MANUAL RESET. IF ANY SMOKE DETECTOR IS ENERGIZED ALL THE AIR HANDLERS UNITS SHALL SHUT DOWN AND THE SMOKE DAMPERS SHALL CLOSE. THE FANS SHALL DECREASE IN SPEED AND STOP. ALL DAMPERS SHALL CLOSE. DAMPERS END SWITCHES SHALL CONFIRM THAT THE DAMPERS ARE CLOSED. VARICONE DAMPERS ARE PROVIDED BY THE MANUFACTURER TO ISOLATE ONE OF THE TWO SUPPLY FANS IF THE FAN IS NOT OPERATIONAL. THESE DAMPERS ARE NOT CONTROLLED BY THE DDC SYSTEM BUT BY AN ELECTRIC CONTROLLER (BY CONTROL CONTRACTOR) TO MANUALLY OPEN OR CLOSE THEM WITH LIGHTS INDICATING THE POSITION OF THE DAMPERS (OPEN /CLOSE). 7. SPECIAL ALARMS: FAILURE OF AHU TO PRODUCE PROPER AIRFLOW AT FT1, FT2 & FT3 FOR MORE THAN 5 MINUTES. B. DAMPERS NOT IN FULL CLOSED POSITION WHEN UNIT IS OFF. PROVIDE DIRECT READOUT OF FINAL FILTER PRESSURE DROP USING ANALOG SENSORS (PT). PROVIDE WARNING ALARM WHEN AT CHANGEOUT PRESSURE. D. VIBRATION TRANSMITTERS (VT) OF ALL AHU FANS SHALL SEND A WARNING ALARM TO THE DDC STTEM WHEN VIBRATION LEVEL IS HIGHER THAN SETPOINT. B. DISCHARGE TEMPERATURE CONTROL: SPECIAL INPUTS (IN ADDITION TO DEVICES SHOWN ON DIAGRAM): A. DISCHARGE TEMPERATURE SETPOINTS TT3 AND 75. B. OUTSIDE AIR TEMPERATURE. AN OUTDOOR SENSOR SHALL PROVIDE INPUT FOR ALL AIR HANDLER CONTROLS. 2. ACTION - OUTSIDE TEMPERATURE BELOW 50 DEG.: A. AHU -1 & AHU -3: ENERGIZE THE STEAM HEATING COIL TO MAINTAIN COLD DECK DISCHARGE TEMPERATURE AT 58 DEG AS MEASURED BY TT2. B. AHU-2 & AHU -4: ENERGIZE THE STEAM HEATING COIL TO MAINTAIN HOT DECK DISCHARGE TEMPERATURE PER A RESET SCHEDULE BETWEEN 85 TO 95 DEG AS MEASURED BY TT4. 3. ACTION -- OUTSIDE TEMPERATURE BETWEEN 50 AND 75 DEG.: A. AHU -1 & AHU -3: ENERGIZE THE COLD DECK AIR ECONOMIZER AS REQUIRED FOR COOLING. MIXED AIR TEMPERATURE IS MEASURED BY TT1. IF AIR ECONOMIZER CANNOT SATISFY THE COLD DECK DISCHARGE SETPOINT, ENERGIZE THE CHILLED WATER COOLING COIL IN ADDITION TO THE ECONOMIZER AS REQUIRED FOR COOLING. B. AHU-2 & AHU -4: ENERGIZE THE STEAM HEATING COIL TO MAINTAIN HOT DECK DISCHARGE TEMPERATURE PER RESET SCHEDULE BETWEEN 75 TO 85 DEG AS MEASURED BY 74. 4. ACTION - OUTSIDE TEMPERATURE ABOVE 75 DEG.: A. AHU-1 & AHU -3: OUTDOOR AIR DAMPER IS AT MINIMUM POSITION TO PROVIDE OUTSIDE AIRFLOW AS MEASURED BY FT6. ENERGIZE CHILLED WATER COOLING COIL TO SATISFY COOLING SETPOINT. AHU -2 & AHU -4: STEAM COIL IS NOT ENERGIZED. HOT DECK TEMPERATURE 1S RETURN AIR TEMPERATURE. 5. SPECIAL ALARMS: A. TT3 AND TT5 LEAVING AIR TEMPERATURES 3 DEG. OR MORE ABOVE OR BELOW SETPOINT FOR MORE THAN 5 MINUTES. WIRES 1/10/09 ACCEPTABILITY This D£S {GN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT DATE DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED DUAL DUCT VARIABLE AIR VOLUME TERMINAL UNITS A. THE DUAL DUCT VAV TERMINAL UNIT SHALL OPERATE VIA THE DDC CONTROLLER. TERMINAL UNIT AIR VALVES SHALL MODULATE TO SATISFY ZONE OCCUPIED HEATING AND COOLING SETPOINTS, INITIALLY SET FOR 70 DEG. F HEATING AND 75 DEG. F COOLING (BOTH SETPOINTS SHALL BE OPERATOR ADJUSTABLE). B. WHEN ZONE TEMPERATURE IS LESS THAN OR EQUAL TO HEATING SETPOINT, THE COLD DECK AIR VALVE SHALL CLOSE TO MINIMUM POSTION AND THE HOT DECK AIR VALVE SHALL MODULATE OPEN TO SATISFY ZONE OCCUPIED HEATING SETPOINT. C. WHEN ZONE TEMPERATURE IS GREATER THAN OR EQUAL TO COOLING SETPOINT, THE HOT DECK VALVE SHALL CLOSE AND THE COLD DECK AIR VALVE SHALL MODULATE OPEN TO SATISFY ZONE OCCUPIED COOLING SETPOINT. D. EACH ZONE SHALL HAVE THE (OPERATOR - SELECTABLE) CAPACITY TO HAVE A DIFFERENT MINIMUM COOLING AIRFLOW SETPOINT. E. THE FOLLOWING POINTS LISTED BELOW SHALL BE MONITORED FOR DISPLAY AND ALARMING THROUGH OPERATOR'S STATION. ALL POINTS SHALL BE DISPLAYED AT STATION, ALARM FUNCTIONS SHALL BE GIVEN. F. A. B. C. 1. TERMINAL UNIT ZONE TEMPERATURE (LOW AND HIGH TEMPERATURE ALARM). 2. TERMINAL UNIT AIRFLOWS (LOW AND HIGH FLOW ALARM). 3. TERMINAL UNIT DISCHARGE AIR TEMPERATURE. CARBON DIOXIDE SENSOR (CO2) IN CONFERENCE ROOMS SHALL MODULATE COLD DECK AIRFLOW TO MAINTAIN CO2 LEVEL BELOW SETPOINT (INCREASE AIRFLOW WHEN ROOM CO2 LEVEL INCREASES). HOT DECK AIRFLOW SHALL MODULATE ACCORDINGLY TO MAINTAIN TEMPERATURE SETPOINT. CO2 ROOM SETPOINT IS CO2 OUTDOOR LEVEL (IN PPM) PLUS 1,000 PPM ACCORDING TO ASHRAE STANDARD 62.1-2004 USER MANUAL, APPENDIX A. NO RESET OF THE AHU'S OUTDOOR AIRFLOW IS REQUIRED. G. DURING UNOCCUPIED TIME COLD DECK GOES TO A LOWER MINIMUM AIRFLOW THAN DURING OCCUP R WED F �yCE TIME( 0.2 CFM/SQFT INSTEAD OF 0.4 CFM /S �QE COMp� D APPRO � N. IN ROOMS WITH OCCUPANCY SENSORS THE CO D DECK SHALL GO TO MINIMUM AIRFLOW WHEN TIE MAY 2 4 2007 ROOM IS NOT OCCUPIED. SINGLE DUCT VAV TERMINAL UNITS( ELECTRICAL ROM THE SINGLE DUCT VAV TERMINAL UNIT SHALL OPERATE VIA THE DDC CONTROLLER. TERMINAL UNIT AIR VALVE SHALL MODULATE TO SATISFY ZONE OCCUPIED COOLING SETPOINT, INITIALLY SET FOR 78 DEG. F COOLING (OPERATOR ADJUSTABLE). WHEN ZONE TEMPERATURE IS GREATER THAN OR EQUAL TO COOLING SETPOINT, THE COLD DECK AIR VALVE SHALL MODULATE OPEN TO SATISFY ZONE OCCUPIED COOLING SETPOINT. WHEN ZONE TEMPERATURE IS LESS THAN COOLING SETPOINT, THE COLD DECK AIR VALVE SHALL CLOSE TO MINIMUM POSITION. D. THE FOLLOWING POINTS LISTED BELOW SHALL BE MONITORED FOR DISPLAY AND ALARMING THROUGH OPERATOR'S STATION. ALL POINTS SHALL BE DISPLAYED AT STATION, ALARM FUNCTIONS SHALL BE GIVEN. 1. TERMINAL UNIT ZONE TEMPERATURE (HIGH TEMPERATURE ALARM). 2. TERMINAL UNIT AIRFLOWS (LOW AND HIGH FLOW ALARM). ISSUE FOR PERMIT DATE 01.15,07 01.15.07 SUBTITLE MECHANICAL MASTER SEQUENCES OF OPERATION 9 -90 RENOVATION BUILDING 9 -90 MISCELLANEOUS EXHAUST FANS AND SUPPLY FANS A. EXHAUST FANS (EF -1, EF -2): EXHAUST FANS SHALL BE COMMANDED ON THROUGH THE DDC AND SHALL BE INTERLOCKED TO RUN WITH AHU-1 & AHU -2 AND AHU -3 & AHU -4. PROOF OF OPERATION SHALL BE REPORTED TO OPERATOR'S STATION. FAN FAILURE SHALL ALARM AT THE OPERATOR'S STATION. B. MECHANICAL ROOM EXHAUST FAN (EF - 3& WALL MOUNTED ROOM TEMPERATURE SENSOR START FAN WHEN ROOM TEMPERATURE IS ABOVE 80 DEG. F (ADJUSTABLE SETPOINT). PROVIDE ALARM TO DDC CONTROL IF ROOM TEMPERATURE IS HIGHER THAN 85 DEG. F. CHILLED WATER COOLING UNITS AC1 K8, AC1K7. AC1 E10, AC1F10, AC1H7, AC1D12, AC1E12, AC1F12, AC1K9, AC1K10, AC2J7. A. CHILLED WATER AIR CONDITIONING UNITS SHALL SERVE THE COOLING NEEDS OF THE NOTED ROOMS. THE UNITS SHALL BE COMMANDED THROUGH THE ROOM DEDICATED THERMOSTAT AND /OR CONTROLLER. B. THE DDC SYSTEM SHALL MONITOR ALL ROOM TEMPERATURES (WITH ADDITIONAL SENSOR) AND PROVIDE ALARM IF ROOM TEMPERATURE IS HIGHER THAN 76 DEG. F (ADJUSTABLE) AND LOWER THAN 65 DEG. F. (ADJUSTABLE). C. D. E. THE DDC SYSTEM SHALL HAVE THE ABILITY TO NOTIFY A MINIMUM OF (4) FOUR SEPARATE BOEING AUTHORIZED PAGER NUMBERS AND A MINIMUM OF (4) SEPARATE BOEING AUTHORIZED CELL PHONE NUMBERS UPON ANY ALARM ASSOCIATED WITH THE SOSAC AND SOSAS SERVER ROOMS. THE DDC SYSTEM SHALL HAVE THE ABILITY TO NOTIFY A MINIMUM OF (4) FOUR SEPARATE BOEING AUTHORIZED PAGER NUMBERS UPON ANY ALARM ASSOCIATED WITH THE DCN ROOM COOIL1NG UNITS AC1J7 AND AC2J7. SMOKE DETECTOR MOUNTED IN CERTAIN UNITS ( SEE SCHEDULE M2B AND M310) SHALL STOP UNIT (BY UNIT CONTROLLER). ALARM SHALL BE REPORTED TO FIRE ALARM PANEL AND TO DDC SYSTEM. IDOMESTIC HOT WATER City Of T111 " G DAN. ALL OPERATING AND SAFETY CONTROLS FOR THE 'Y�DY� DOMESTIC HOT WATER HEATER WHP1R5A SHALL BE FACTORY FURNISHED AND WIRED. N FFMAN 6 I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 - 1625 206 623 0717 Fax 206 624 3775 B. DOMESTIC HOT WATER CIRCULATION PUMP PUP 1 P5A START /STOP AS SCHEDULED BY DDC SYSTEM. STEAM METER DDC CONNECTION A. PROVIDE AN ANALOG INPUT FOR STEAM FLOW TOTALING OF THE STEAM METER. LIGHTING CONTROL DDC CONNECTION A. PROVIDE DIGITAL OUTPUTS TO THE LIGHTING CONTROL SYSTEM. (EIGHT LIGHTING PANELS WITH FOUR OUTPUTS EACH). DEV. CENTER, WA CURRENT REVISION SHEET JOB NO. DWG NO. M311 150680-01 SYMBOL RIG 9--- 90 --M311 APR 0 9 2001 PERMIT CENTER DATE 04.05.07 COMP NO. F &T TRAP TO 9-96 3" PUMPED CONDENSATE FROM 9-96 SYM REVISION 2- 1/2 " -15# U 0— ORIG 9 -90 RENOVATION J #150680.01 HC -4 CPP —PB BY COFFMAN 3/4" LPS STEAM HEATING COIL (NP) 4 " -15 4 "--15# APPROVED DATE M. SOTURA 04.05.07 MPS SYM CPP —PA PP- 41 LPS F -' 1 -1 /2" LPC " - 15# 3/4" --I I— PUMP TRAP (TYP) PC REVISION I. 11 1/ STEAM METER -� 6 " -15# STM HEADER 11 PC DUPLEX PRESSURE POWERED. CONDENSATE PU LOCATED IN PUMP ROOM 12J6 ON FIRST FLOOR STEAM SYSTEv DIAGRAM (T) SCALE: NONE : 14y12 BY F &T TRAP LPC Sew APPROVED DATE PRV ---1 1300 LBS /15# — PRV -2 -3900 LBS/14.6# i - F I 3/4" IHHH lIE-fl —r- VIP AND RECEIVER —I✓- PUMP TRAP (TYP) CPP —PC SLEEVE (TYP) �I LPC DIRT LEG & THERMODYNAMIC TRAP 250 LBS /HR �B OE /N� 4" LPC SEE DETAIL 5/509 - CPP —PD (TYP) 4 "VTR FIRES 1/10/09 LPC CONDENSATE RECEIVER CPP -1B PC CONDENSATE PUMPS MPS 0_ THERMODYNAMIC TRAP 1/ 6 " DIRT LEG & THERMODYNAMIC TlrAP 60 LBS /HR 2 1/2 "1 1 » PC 1 60 PSI_ CONDENSATE RECEIVER =F Fp } CPP-1A CONDENSATE PUMPS ISSUE FOR PERMIT CHECKED APPROVED APPROVED ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN CHECKED M.SOTURA ENGINEER 01.15.07 1� e1�❑ 3" VENT I 10--- PC DATE SU BTITUE 01.15.07 TITLE 71 z 1" VENT H PRV -3 50LBSj60# 3/4" MECHANICAL MASTER N_ I U) 0_ U 0, H 1 + 1 PENTHOUSE 2ND FLOOR 1ST FLOOR MPS DRAIN VALVE DIRT LEG & THERMODYNAMIC TRAP 1100 LBS /HR DUPLEX PRESSURE POWERED CONDENSATE PUMP AND RECEIVER LOCATED IN MECHANICAL ROOM 11V6 ON FIRST FLOOR ACOFFMAN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 STEAM SYSTEM DIAGRAM 9 -90 RENOVATION BUILDING 9 -90 6 "125# PSI z 3 PC —Z LEGEND PC CONDENSATE RETURN (PUMPED) C CONDENSATE RETURN (GRAVITY) MPS STEAM SUPPLY (MEDIUM PRESSURE) LPC CONDENSATE, STEAM (LOW PRESSURE) —I — STEAM TRAP 2 WAY CONTROL VALVE W /ELECTRICAL ACTUATOR PRESSURE REGULATING VALVE (SELF CONTAINED) PRESSURE RELIEF VALVE / SAFETY VALVE SWING CHECK VALVE WITH FLOW R I BALL VALVE, OPEN WYE STRAINER (WITH DRAIN VALVE) cal GLOBE VALVE, CLOSED GENERAL \OTES REFERENCE DRAWINGS 1M61, FIRST FLOOR HVAC PIPING PLAN 1M62, FIRST FLOOR HVAC PIPING PLAN 1 M63, FIRST FLOOR HVAC PIPING PLAN 2M61, SECOND FLOOR HVAC PIPING PLAN 2M62, SECOND FLOOR HVAC PIPING PLAN 2M63, SECOND FLOOR HVAC PIPING PLAN P1 M450, ENLARGED WEST PENTHOUSE PLAN P1 M451, ENLARGED EAST PENTHOUSE PLAN CONSTRUCTION NOTES TO BOILER HOUSE DEV. CENTER,WA CURRENT REVISION SHEET GATE VALVE, OPEN LATERAL JOB NO. DWG NO. M312 SYMBOLQ R I C 150680 -01 9- 90 —M312 DATE RECEIVED LA APR 0 9 2807 PERMIT cEUTEr COMP NO. 04.05.07 8 r ,'; 4 . ■ j; c` f' {� I 0 SYM ORIG 1 9-90 RENOVATION TO CONDENSATE PUMP, SEE M509 REVISION PROVIDE NEW TAMPER SWITCH AT EXISTING POST INDICATOR VALVE. COORDINATE WIRING WITH ELECTRICAL & ADT 41150680 -01 COMPRESSED PLANT AIR, SEE FLOOR PLANS ALARM GONG C BY COFFMAN { APPROVED M.SOTURA :t4 - A -�--t- s 3/4' DATE 04.05.07 SYM PRESS SWITCH HOSE END .. , BALL VALVE MECH 11J6 E !STING DRY PIPE FIRE S RINKLER ALARM VALVE A SEMBLY TO REMAIN Tg- f QUICK DISCONNECT COUPLING (TOOL HOSE) EXISTING DRY PIPE FIRE SPRINKLER ALARM VALVE A r 3/4" (....„ EXTEND DRY SPRINKLER PIPING TO AREAS SUBJECT TO FREEZING, SEE FLOOR PLANS ► L J Li REVISION PROVIDE NEW FLOW SWITCH, COORDINATE WIRING WITH ADT A I 3 / 4 'L EXISTING ALARM GONG ;p TO REMAIN FLOW SWITCH F --s IT} I T I 3 BY APPROVED FIRE SPRINKLER DIAGRA SCALE: NONE 1/2"A TO PNEUMATIC CONTROL AIR TO BE EXTENDED BY CONTROLS SUB - CONTRACTOR TO AIR OUTLETS I 1 3 PENTHOUSE ITI IT L.l DATE COvIPRESSED PLANT AIR DIAGRA SCALE: NONE EXTEND DRY SPRINKLER PIPING TO AREAS SUBJECT TO FREEZING, SEE FLOOR PLANS EXISTING ALARM GONG TO REMAIN FLOW SWITCH �-- F V EXISTING DRY PIPE FIRE SPRINKLER ROOF ALARM VALVE I III PROVIDE NEW FLOW SWITCH, �✓� COORDINATE WIRING WITH ADT V PRESS SWITCH EXISTING DRY PIPE FIRE SPRINKLER ALARM VALVE ASSEMBLY TO REMAIN rTh d 315 M315 THIS DESIGN SPECIFICATION I APPROVED BY 1/2"A TO PNEUMATIC CONTROL AIR TO BE EXTENDED BY CONTROLS SUB-CONTRACTOR A 3/4" 3/4" TO AIR OUTLETS E T � PENTHOUSE ��' �'�' ITIITI3IIT, I0I4 DRAWN ACCEPTABILITY COFFMAN COMPRESSED PLANT AIR, SEE FLOOR PLANS APPROVED ,�- 3/4" HOSE END BALL VALVE TO MECH 11V7 CONDENSATE PUMP, SEE M509 1 1/ 1- i ISSUE FOR PERMIT DEPT. DATE CHECKED M.SOTURA ENGINEER CHECKED APPROVED DATE 01.15.07 01.15.07 3/4 PUMP PIT FLOOR HOSE END BALL VALVE TITLE MECHANICAL MASTER 9-90 RENOVATION BUILDING 9 -90 PENTHOUSE ALARM GONG , 1[) 2ND FLOOR - 1ST FLOOR QUICK DISCONNECT COUPLING (TOOL HOSE) 90 PSI I, FROM CENTRAL PLANT I � A-I�I� ROOF REVIE\NED FOR CODE COMA 2ND FLOOR AVIC IPSWE15 MAf 2 201 0 IV is Ot 1ST FLOOR B �FFMANI R 6 1N FS N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1 625 206 623 0717 Fax 206 624 3775 SUBTITLE OMPRESSED AIR & FIRE SPRINKLER DIAGRAMS DEV. CENTER,WA CURRENT REVISION SHEET JOB NO. DWG NO. ( ------ PROVIDE NEW TAMPER SWITCH AT EXISTING POST INDICATOR VALVE. COORDINATE WIRING WITH ELECTRICAL & ADT sY " a° `ORIG M315 150680 -01 9-- 90 --M315 RECEIVE" CITY OFTtIK';A >rt `APR 0 9 2007 PERMIT ICE,'» . DATE COMP NO. 04.05.07 NON—AIR TIGHT SIDING LOW PRESSURE PLENUM CEILING EXHAUST AIR DUCT AIR TIGHT SIDING GUARD RAIL L LOW PRESSURE ( INCLINED PLENUM WALL EX WIT FIR 15 EX SUSPENDED CEILING AIR INTAKE HO D ATMD, OUTSIDE AIR FLOW MEASURING STATION RETURN AIR DAMPERS 3 © S-0"x8'-0" AUST GRILLE MANUAL & DAMPER 0 CFM AUST AIR DUCT 2'-6"x10'-0" EXI- AIR DAMPER LOW PRESSURE PLENUM WALL . " 1 " ---- -RETURN AIR FAN 96"x48 AIR BLENDER AHU-2 INTAKE DUCT BEYOND VVVV VV <11 MOTOR OPERATED MOTOR OPERATED MOTOR OPERATED RETURN AIR DAMPER 41 RETURN AIR DA PER <I] RETURN AIR DAMPER 3'-0"x8 3'-0"x8'-0" FLEX CONN RETURN FAN S ECT1 0\1 SCALE: 1/4"=1 ALL AROUND 7- CURB SLOP: TO FLR DRAIN if INTEGRAL STEEL BASE ■4 PROVIDE NEW ISOLATION RESTRAINTS EGRAL STEEL BASE OUTSIDE AIR DAMPERS 3 © 4!-0"x6 EAST PENTHOUSE AS SHOWN WEST PENTHOUSE OPP. HAND LOW PRESSURE FLEW M CEILING mass EAST PENTHOUSE AS SHOWN WEST PENTHOUSE OPP. HAND SECTION SCALE: 1/4"=1'-0" INCLINED LOW PRESSURE PLENUM WALL 5'-9" T APPROVED DATE PLEC JUM 5'-9" P1M451 M500 P1M45:11k INTEGRAL STEEL BASE AC.C.S5 DOCR c==j: FAN FLEX SOUND AlTENUATOR LTeAfW :T to EXPIRES 1/10/09 NON-AIR TIGHT SIDING •■■■=0,,i 24x18 DUCT WITH MOTORIZED AIR DAMPER EXHAUST AIR LOUVERS 24"x24" ACCESS DOOR AIR TIGHT SIDING PENTHOUSE FLR EL 43-10 1/2" ORIG SYM 9-90 RENOVATION REVISION 4150680-01 28 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. MAN BARS (TYP 5) -32/36 ACCESS DOOR OW 5) ISSUE FOR PERMIT DATE DRAWN COFFMAN CI-TERED M. SOTURA ENGINEER CHECKED APPROVED APPROVED D TE 01.15.07 01.15.07 SUBTITLE MECHANICAL MASTER PENTHOUSE SECTION 9-90 RENOVATION BUILDING 9-90 SEAL MIXED AIR PLENUM BETWEEN NEW AHU & PLENUM CEILING NOT USED SEE DWG P1M3 FOR NEW FLOOR DRAIN INSTALL NEW AHUS ON 6" HIGH x 12" WIDE CONCRETE CURB & ANCHOR AHUS TO EXISTING SLAB PROVIDE NEW ISOLATION RESTRAINTS PROVIDE NEW MOTOR PROVIDE NEW AIRFLOW MONITORING STATION PROVIDE NEW RETURN AIR DAMPERS CLEAN OUTSIDE AIR LOUVER MESH SCREEN AFOFFMAN NGINEERS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 CO DEV. CENTER,WA LE3E\ID GENERAL OTES REFERENCE DRAWINGS STRUCTION KEEP EXISTING RETURN FAN PROVIDE NEW SEISMIC RESTRAINT FOR EXISTING RETURN FANS PROVIDE NEW 7.5 HP INVERTER DUTY MOTOR PROVIDE NEW FLEX CONNECTION AT RETURN AIR FAN REMOVE EXISTING DAMPERS AND PROVIDE NEW RETURN AIR DAMPERS AND NEW EXHAUST AIR DAMPERS PROVIDE NEW 24x18 DUCT WITH MOTORIZED DAMPER AND FIRE DAMPER ATTACH 96"x48"x36" AIR BLENDER TO CASING REMOVE ALL FOUR EXISTING OUTSIDE AIR DAMPERS. PROVIDE 3 NEW DAMPERS SAME SIZE AS PREVIOUS. SHEET METAL TO BLOCK ONE OPENING. CURRENT REVISION SHEET JOB NO. DWG NO. M500 150680-01 OTES 9-98-M500 MEW° CITV TI -IK'N/LA APR 0 9 2007 PiRWT CE DATE 04.05.07 COMP NO. 3 E (TYP)- - -mg 1111 RETUF TO NI ..... / Ill w...-.... . . .". ..._ 9111111Pli CEILING T-BAR :.... co w cc ALL C UNITS ENGIN BRAM TOP OF SERVERSi- l k, RAISED FLOOR-- - 16" DEEP BEAM FLEXIBLE DUCT ARCHITECTURAL CEILING FACTORY DIFFUSER PLENUM (INSULATED) SHEETMETAL EXTENSION (APPROX. 1 2" HIGH) (INSULATED) SIZED TO MATCH FACTORY DIFFUSER PLENUM DIMENSIONS FLOWBAR LINEAR SLOT DIFFUSER SECOND FLOOR SCALE: 1 /2 =1 8"95 SYM ORIG 9-90 RENOVATION REVISION 4150680-01 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 SECTICN AT V AIN E 24/1O� DOUBLE-WALL 1 " INSULATED DUCT VOLUME DAMPER (MOUNT IN ACCESSABLE LOCATION FROM LOBBY) \ITRY 1M13 M501 RETURN GRILLE LOCATED ABOV CEILING T-BAF LI EB ERT "XDO" RETURN DUCT PERFORATED FLOOR TILE SECTION AT SERVER RON SCALE: 1 /2"= 1 '-0" AiraTASIAV ® STRUCTURAL FRAME FOR (4) HANGING RODS (TYPICAL EA. "XDO" COOLING UNIT) RETURN DUCT WITH XDO 1MdM,501 N GRILLE TIGHT RTH WALL (TYP) VERHEAD "XDO" TO HAVE EERED SEISMIC G (TYPICAL) ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. ISSUE FOR PERMIT DATE DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTITLE TITLE MECHANICAL MASTER SECTIONS 9-90 RENOVATION BUILDING 9-90 AFOFFMAN NGINEEKS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 206 623 0717 Fax 206 624 3775 DEV. CENTER,WA CURRENT REVISION SHEET JOB NO. DWG NO. sm 'ORIG M501 150680-01 9-98-M501 COMP NO. RECEIVED Cinf OF 11 JKWILA APR 0 9 2007 PERMIT CE (h DATE 04.05.07 I . 2"x11" GA INSERT TO 12" SQUARE D CT 2 "x 11 GA. INSERT AN BAR DETAILS SCALE: SCALE: NONE DUCT 1 /2 "SQ BETWEE TO 12 "95 DUCT 1 DU ACCESS DOOR FLEX DUCT SECURE /SECURE DUCT SCALE: NONE TYP RIVET 1 /2" OSTEEL BAR DUCT TYP 1 /2" OSTEEL BAR WIRE MESH CROSS BARS TYP IVET 2 "0 STEEL BAR T ORIG REVISION 9-90 RENOVATION J#150680 -01 BY COFFMAN APPROVED M. SOTURA DATE 04.05.07 SECURE SIDE OF WALL tr i RI X CD TYP 1/8 2 "x11 GA. INSERT TYP> v MANBARS WITH STEEL SCREEN WALL PENETRATION 6 "MAX 6 "MAX DUCT VET 6 "MAX OVER 12 "SQ DUCT 1 /2 "SQ WIRE MESH BETWEEN CROSS BARS TYP > /5 6' MAX 6' MAX OVER 12 "0 DUCT SECURE SIDE OF WALL CAPACITANCE GRID ALARM 1/2"0 STEEL BAR I � 1 TYP M502 RIVET 6 "O.C. MAX DUCT 1 TYP M502 FLEX DUCT ' ACCESS DOOR - SIZE AS REQUIRED TO CONNECT WIRES TO CAPACITANCE GRID DUCT SECURE /NON SECURE DUCT WALL PENETRATION n SCALE: NONE DUCT NOT TO SCALE r EXPIRES 1/10/09 UNSECURED SIDE OF WALL 3 rr 3 2 3 3 3 MANBARS WITH STEEL SCREEN UNSECURED SIDE OF WALL MANBARS WITH STEEL SCREEN SECURE SIDE OF WALL FLEX DUCT SECURE SIDE OF WALL FIRE DAMPER ACCESS DOOR SIZE AS REQUIRED FLEX DUCT ACCESS DOOR - SIZE AS REQUIRED SECURE /NONSECURE ONE HOUR PENETRATION ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE i ISSUE FOR PERMIT DRAWN COFFMAN CHECKED M. SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 TYP M502 TYPIM502 SUBTLE TITLE MECHANICAL MASTER N FF AN i I N E E K S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 DETAILS 9 -90 RENOVATION BUILDING 9 -90 NOTES: ACCESS DOORS: 12/12 MINIMUM SIZE : VISION PANELS FOR CHECKING SECURITY DEVICES, : HIGH PRESSURE IN H,P. DUCTS, f)FV. t;FNTFR WA CURRENT REVISION SHEET DWG NO. M502 JOB Na 150680-01 SYMBOL^ R I G 0 _0Q- A fl V) DATE RECEIVE CITY Cc TUKWILA APR 0 9 2007 PC..MJt cE/s', COMP NO 04.05.07 •Ii If; k; ; PI• r I E4 it SECURITY BARS & WIRE MESH ---- 1,4 ►I { k 22 GA GALV PI I IF*1 HI a s —,2 ,-N. - ----..... 44. 1 1 N it SYM ORIG AS CLOSE AS POSSIBLE NON— SECURE SIDE 18 GA SHT METAL COLLAR, FASTEN TO WALL & DUCT DUCT RECTAN SCALE: NONE SECURITY SILE SCALE: SCALE: NONE RED SILICON INSULATION FILLER RTV-- 106 PVC INSULATOR SHEETMETAL DUCT TERMINAL POINT X21 DRILL 10 -32 TAP (2 PLACES) 3" MIN 6" MAX CER DETAIL 1 1/4x1 1/4x1/8 L SUPPORT & BRACE TO STRUCTURE ABOVE, (TYP 4). PROVIDE CROSS BRACE EA END OF SILENCER SECURE SIDE NON— CONDUCTIVE FLEX CONNECTION SILENCER, SEE SCHEDULE ELEVATIO N BY COFFMAN ALUM ANGLE POP RIVET GULAR DUCT CAPACITANCE GRI APPROVED M. SOTURA DATE 04.05.07 DUCT SYM 12 "x12" ACCESS PANEL (I) NP M503 1/4" ALUM ROD @ 6 "O.C,WELDED TO ALUM ANGLE "xl "xI /8 "ALUM ANGLE (TOP AND BOTTOM) /4 "MIN,THICKNESS PVC OR AN APPROVED MATERIAL THAT I S NON—CONDUCTIVE (TOP AND BOTTOM) 5 TYPIM503 REVISION M503 BY 4 4 L 4 ACCESS DOOR SCALE: NONE M503 6 ' WALL 30 "x24" RA UNSECURED SIDE APPROVED PLA SCALE: NONE DATE 4 6" O.0 (TYP) 0 2'--6" 30 "x24" RA SECURED SIDE 1 a 4 ( � 1 TYP M503 6 TYPIM503 ASPAZEZAW® I mums 1/10/09 F ROM I,iA 3o'Y2REp ARC SE SECURITY BARS 30 "x24" RA TO BLDG PLENUM INSECURED PLENUM TRANSFER DUCT r Td503 SCALE: NONE ROOF , �, �� R p TL 3a >< G 0R E0 P BLA & WIRE MESH CAPPED ROOM SECTION SCALE: NONE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE " DRAWN COFFMAN CHECKED M. SOTURA ENGINEER ARp 0N) 1 /2 f (2X M O 0' 2' -6" CORRIDOR SECURED ISSUE FOR PERMIT CHECKED APPROVED APPROVED (/77 TYP M503 DATE 01.15.07 01.15.07 TITLE 30 "x24" RA FROM SECURED AREA PLENUM MECHANICAL MASTER FLOOR OR WALL SECURE SIDE NON SECURE SIDE MAN BAR DETAIL (Th SCALE: NONE TYP M503 BARS WIRE MESH WALL - 9 -90 RENOVATION BUILDING 9 -90 SECT IO SCALE: NONE N FFMAN 6 IN E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 2' -6" DUCT SIZE SUBTITLE DETAILS MAN BAR BMAC STD 83 -1 INSPECTION WINDOW 10/6 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 4 207 c l� Qf Tukwila ILDIN DIVISION S TYPIM503 DEV. CENTER,WA DWG ND. w N j CURRENT REVISION SHEET M503 sYMBOL JOB NO. 150680 --01 9-98—M503 DATE FtECENEO crTv o;. TUKWILA APR 0 9 2007 AM6T CH 04.05.07 COMP NO. r' I '1 PIPE SIZE BOLT SIZE a LENGTH NUT SIZE DISTANCE BETWEEN LITERAL BRACES 4" & BELOW ETB X 1 1 2 BOLT ©Ly 40' -0" MAx. 6' ©8 X I 1 2 BOLT Q,(4 40' -0' MAX. 8 " U8 X I 1 2 BOLT E7,�i 20' -0 MAX. PIPE A SIZE LENGTH 1' SCH 40 O'-O' TO 7' -O' 1 1/4' SCH 40 7' -0' TO 9' -0' 1 1/2" SCH 40 9' -0' TO 1O' -4" 2 SCH 40 10' -4" TO 13' -1' PIPE SIZE BOLL 512E DIM A UP TO 1-1/2' 1/2 1/8" 1/4" 2' TO 6' 3/4' ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED COFFM c 01 15.07 CHECKED M. SOTURA 01.15.07 ENGINEER APPROVED BY DEPT. • DATE CHECKED APPROVED APPROVED SYM BRIG HANGER -- ' ROD (TYP.) EQUIPMENT EQUIPMENT ADD FRAMING CHANNEL OR ANGLE WHEN 'I.' IS GREATER THAN LW. LENGTH SAME AS OPPOSITE SIDE PIPE HANGER SCALE: NONE 9 -90 RENOVATION SCALE: NONE REVISION SYMMETRICAL ABOUT ELEVATION SLACK CABLE FOR VIBRATION ISOLATED EQUIPMENT (TYP.) PLAN ELEVATION FOR CHANNEL SIZE AND CONNECTION SEE SMACNA BRACE SIZING TABLE CABLE BRACING SEE SMACNA NOTE; 1. SEE SMACANA BRACE SIZING TABLE FOR VERTICAL HANGERS, DIAGONAL BRACES, BOLT SIZE & CONNECTION TO SUPPORTING STRUCTURE. lI 1 N WITH TOP SUPPORT POINTS 1 -1/4" 1-1/4" PIPE HANGER ROD CLIP CONNECTION TYPE A THRU D BENT P 13`X1/4" E THRU H BENT R 4X3/8" ADD PIPE SLEEVE THAT WAS AN INSIDE DIMER, 1/4' ± LARGER THAN OUTSIDE DIAMETER OF BOLT. J#150680 -01 BY COFFMAN QUIP. FRAME OR Z 1UPPORT POINT APPROVED M.SOTURA EISMIC CABLE BRACE (PIP.) SUSPENDED EQUIPMENT SEISVIC BRACING DETAIL n J5O3 LONGITUDI CABLE BRACE WASHER COVER WELD HEAVY PIPE CLAMP SCALE: NONE DATE 04.05.07 HORIZONTAL BRACE 3 3/16" HORIZONTAL BRACE 9 NOTE: SEE SMACNA TABLES FOR VERTICAL HANGERS, DIAGONAL BRACES, BOLT SIZE, AND CONNECTION TO STRUCTURAL SUPPORT. TYPICAL CABLE TRANSVERSE TYPICAL CABLE BRACE AT PIPE HANGER n LOCITUDI\AL BRACE J M503 11lfTTHHSE r BRACE 1/2' ((1 ) CLEAR MAX. VERTICAL HANGER LONGITUDINAL BRACE HORTZOMAI ONE EACH SIDE OF BRACE DUCT. (SHOWN DOTTED) ■IMii CENTER BRACING FOR RECTANGULAR DUCTS SCALE: NONE SECURE ANGLE WITH 3 MASON SRO CLAMPS ROD AND WL'RTICAL HANGER WELDED BEAM ATTACHMENT It 3'X1/4" REVISION — L1/4" MIN. 1 1 (MIN.) CABLE BRACING SEE SMACNA • 1/2" (12.7 mm) CLR MAX. CONNECTION TO SUPPORTING STRUCTURAL MEMBER ft OF BOLTS & SCREWS EQUAL Q OF ANGLE BY CONNECTION TO SUPPORTING STRUCTURAL MEMBER ��E LONGITUDINAL BRACE ONE EACH SIDE OF DUCT. (SHOWN DOTTED) 1/2' (12.7 mm) CUT MAX. Q OF BOLTS & SCREWS EQUAL Q OF ANGLE SIDE BRACING FOR RECTANGULAR DUCTS SCALE: NONE TFWIVITRTSE BRACING SAME AS MIER SAME INSULATION WTI J REVD (5 M503 SEE MR TWEE 8/51.2 SECTION NOTE: 1. SEE SWCNA TRAPEZE BRACE Slit TABLE FOR VERTICAL WINGERS, TRANSIERSE AND IAHGRLIODW. (FACES, BOLT SIZEE, CONNECTION TO STENCTUIU. SUPPORTING MEMBERS, FAfD SPACING OF BRACING. APPROVED DATE BENT A 3 H 0 BENT 4X3/8' 1 -1 STRUT BRACING FOR PIPE TRAPEZE SCALE: NONE 3 a 3 TI ' ' ---- -- CONNECTION TO SUPPORTING STRUCTURAL MEMBER-----"Th Q OF BOLTS & SCREWS EQUAL Q OF ANGLE TRANSVERSE CABLE BRACE II UPI !I MAXflAUU TRAPEZE SPAN (SEE TABLES) VERNA. SUPPORT SAME AS OPPOSITE SIDE LOTat IDIWL BRACE ONE EACH END OF TRAPEZE (SLOPE SAME AS TRANSVERSE BRACE). STRUT GTVNR L CAN BE USED PER 4/S12 (LONGBUDTHM. BRACE AT OPPOSITE END NOT SHOWN FOR mom ADO VERTICAL ANGLE FROM SCHEDULE WHEN 'L' GREATER THAN WWII LENGTH SUPPORTING NEMEER 1WIGER ROD [� HOLDOwH COMP TIRO & 1i /4' SO. glAINWAINNINNO 41 9111 0 Q OF BOLT B. OF ANGLE • 1 -1/2• B T1SUERSE 11 d3503 HORIZONTAL SCALE: NONE a AFISPAEZAW ® 0p OF BOLTS E Q OF ANGLE CONNECTION TO SUPPORTING STRUCTURAL MEMBER LONGITUDINAL CABLE BRACE EACH SIDE OF HANGER EA. SIDE OF DUCT. SEE SMACNA SEISMIC SEE SMACNA SEISMIC RESTRAINT MANUAL RESTRAINT MANUAL M. 9 -3 FIG. 9 -1 OR 9 -4 OR 9-2 VRUICAi. SUPPORT SAME AS OPPOSITE SIDE LONGITUDINAL CABLE BRACE SE 3/S12 SAYE AS OPPOSE SIDE NOTE 1. SEE SLEACNA TWEE BRACE SLANG TABLE FOR VERTICAL HANGERS, TRANSVERSE AND 1WNGLNDIHAL BRACE, EOLT SE, CONNECTION ID SU M MD OF� SCALE: NONE SCALE: NONE ADO WHAM ANGLE FROM TABLE WE '1 GREATER THAN UMW LENGTH 2 NM I MIN A 1NRU BENT f E TW 1 H BENT R 4"X3/8' CONNECI@H TYPE A THRU D DENT E 311/H BENT R 413/8" CONNECTION TO SUPPORTING STRUCTURAL MEMBER q. OF BOLTS EQUALS Q OF ANGLE SEE SMACNA SEISMIC RESTRAINT MANUAL FIG. 9 -3 OR 9-4 SEE SMACNA SEISMIC RESTRAINT MANUAL FIG. 9-1 OR 9 -2 CABLE SIDE BRACING FOR RECTA\GULAR DUCTS J ! 503 r; 3 CABLE CENTER BRACING FOR RECTANGULAR DUCTS ( J5O3 IMMERSE CABLE HANGER BRACE SEE 3/51.2 ROO LONGITUDINAL CABLE BRACE EACH SIDE OF HANGER EA. SIDE OF DUCT CABLE BRACING FOR PIPE TRAPEZE iz y503 E%ISBNG CONNECTION TO SUPPORTING STRUCTURAL MEMBER TRANSVERSE BRACE 2 MAX 1 MIN PIPE HANGER ROD CLIP CONNECTION TYPE A THRU Ti BEM P 3T11/4" E THRU H BENT P 4153/8" EXPANSION ANCHORS SHOWN HERE FOR EXAMPLE NOTE: I. SEE SMACNA BRACE SIZING TABLE FOR VERTICAL HANGERS, DIAGONAL BRACES, BOLT SIZE & CONNECTION TO SUPPORTING STRUCTURE. ADD PIPE SLEEVE THAT WAS AN INSIDE IXA A TE"R, 1/4" LARGER THAN OUTSIDE DIAMETER OF BOLT. EXISTING PIPE HANGER TYPICAL RIGID IRAN BRACE AT PIPE HAS SCALE: NONE L #10 SELF TAPPING SCREWS 6' (100 MM) 00. MIN. ROD PER SMACNA TABLE 5-2, 6 -2, 7 -2) UI r ADD VERTICAL HANGERS ANGLE FROM TABLE WHEN 'L' GREATER THAN MAXIMUM LENGTH PER TABLE SECURE WITH 3 MASON SRC CLAMPS. PENDENT W/ ESCUTCHUN. SUBTITLE TITLE MECHANICAL MASTER TYPICAL SPRINKLER RELOCATION ASSIVEBLY SCALE: NONE FOR INFORMATION ONLY CONNECTION TO SUPPORTING STRUCTURAL MEMBER HORIZONTAL BRACE 6" (150 1 X 1/2' R.C. PENDEN1 WI ESCUTCHUN. M503 J M503 SEISMIC BRACING DETAILS 9 -90 RENOVATION BUILDING 9 -90 TYR TRAPEZE W /BBL NUTS FOR BOLT SIZE SEE TABLE 1 " -24" DIAGONAL BRACE SEE TABLE FOR SIZE (3.18 MM) (25.4 -- 610 MM) _________H ADD VERT. HANGERS FROM SCHEDULE WHEN "L" IS GREATER THAN MAX. LENGTH TABLE. TRANSVERSE BRACE J1 TN 1 2 MAX LONGITUDINAL BRACE. ONE EACH SIDE OF DUCT. BENT PLATE CONNECTION TYPE A THRU D 3 "x1 /4" (75mmX6.4mm) CONNECTION TYPE E THRU H 4x3/8" (100mmX9.53mm) 1 -5/8" X 1 --5/8" x 14 GA. 1 /2 3 (12.7 MM) BOLT TO TRAPEZE, #10 SELF TAPPING SCREW TO DUCT. SIDE BRACING FCR RECTANGULAR DUCTS SCALE: NONE 2 MAX 1LAN LONGITUDINAL BRACE NOTE: INSTALL BRACES SHOWN WITHIN 4' OF HANGER CONSTRUCTED PER 5/51.1 OR 6/S1.1 WITHOUT BRACING MEMBERS SVERSE ALTERNATE RIGID GER (7 TRANSVERE SCALE: NO PIPE CLAMP & TO=GO FIG. 910 SWIVEL FITTING STRUCTURAL BEAM NUT, PER SCHEDULE PIPE BRACE, PER SCHEDULE DEV. CENTER,WA CURRENT REVISION SHEET GOVERNING AUTHORITY APPROVED SPLIT STEEL HANGER JOB NO. DWG NO. ATTACHMENT TO STRUCTURE: M504 150680 -01 dM503 TRANSVERSE BRACE FOR AU. SIZE PIPE UP TO 6' U BOLT FRAMING CHANNEL STANDARD PIPE CLAMP 1 -5/8' WIDE REVIEWE COMPLIANCE CODE APPROVED MA`i 2 4 200 City Of T k iia ILDIN . D N 8 2M260,1,2,3 BOLT, PER SCHEDULE M503 TYPICAL SPRINKLER SEISMIC BRACE ASSN/ SCALE: NONE A qualified professional engineer (QPE) familiar with all of the applicable codes and design standards related to seismic protection of HVAC components and qualified in structural design of seismic protections and their interaction with building structures shall be responsible for execution of the work herein. Shall be responsible for the preparation of drawings, analysis, installation specifications, eta and final inspection of the seismic protections required by applicable codes. CITY Of T'UK vtt A "APR 0 9 2007 PERMIT SYMBOLO R I G 9- 90 —M504 EBLY �4 — M503 DATE COMP NO. 04.05.07 'S C r u c y C C 0 I , • i 111 j lil , . ;I 1 ; III I I I I I; If, IT I I'. ' MAXIMUM HOT DUCT CFM (PER PLANS) HOT DECK INLET SIZE HOT DUCT BRANCH SIZE 0 -170 4 6 171 -340 6 8 341 -700 8 10 701 -1000 10 12 1001- 1400 12 14 1401 -2000 14 16 SYM ORIG FLEXIBLE DUCT SEE PLANS OR DIFFUSER SCHEDULE FOR SIZES, SEE SPECIFICATIONS FOR MAXIMUM LENGTH RECTANGULAR TO ROUND DUCT TRANSITION PROVIDE 1/4" BEAD AROUND COLLAR FOR CLAMP CATCH SMACNA APPROVED CLAMP NOTE: 1. FLEXIBLE DUCT TO DIFFUSERS SHALL NOT BE USED ABOVE NON-REMOVABLE HARD CEILINGS. USE RIGID DUCT CONNECTIONS. SCALE: NONE MAIN TRUNK DUCTS AIR FLOW COLD SUPPLY DUCT STRAIGHT GALV INSULATED ROUND DUCT, MIN DISTANCE OF 3 TIMES BOX INLET SIZE SHEET METAL TRANSITION AS REQUIRED, TYP. CONTROL BOX (TYPICAL) MINIMUM 36" SERV CLEARANCE FOR CONTROL PANEL ON COLD DECK SIDE. DUAL DUCT TER SCALE: NONE 9 -90 RENOVATION REVISION PAN J #150680 --01 2. ACOUSTIC LINING ONLY REQUIRED ELEVATION AT CONFERENCE ROOMS. BY COFFMAN DIFFUSER NECK SIZE 1/2 DIFFUSER NEC SIZE ALL SIDES SQUARE OR ROUND DIFFUSER NECK. REFER TO D{2AWINGS/ SPECIFICATIONS FOR TYPE AND S ZES. DIFFUSER BdOT W/ 1" ACOUSTIC LINING, SEE NOTE 2. DIFFUSER STRAP HANGER WHERE REQUIRED INAL UNIT DETAIL APPROVED M. SOTURA DIFFUSER BOOT W/ 1" FIBER -FREE ACOUSTIC LINING, SEE NOTE 2 MINIMUM 1/2" DIFFUSER NECK SIZE PLUS 2" CEILING TYPICAL RESTRICTED CEILING HEIGHT DIFFUSER CONNECTION (Thi AM505 DIFFUSER REFER TO RAWINGS/ SPECIFICATI NS FOR TYPE AND IZE 45 DU sT TAKE- -OFF FITTING HOT SU FLEX Dl TYP. MINIMU CLEARA DECK D ACTUAT( MOUNT!P TO STR� SPRING PER SP NOTE: FOR COLD DUCT SIZING, REFER DUAL -DUCT SCHEDULE ON SHEET M2C. FOR HOT DUCT SIZING REFER TO CHAR DATE 04.05.07 PLY DUCT CT IF NEEDED, 12" SERVICE CE FOR HOT MPER R. G RODS UP ICTURE W/ ISOLATORS :CIFICATIONS DUAL D�1CT VAV TERMINAL UNIT ( LOW VE OCITY SUPPLY AIR DU T, SEE FLOOR PLANS. NO LIN R INSIDE DUCT. PROVID EXTERNAL INSULATON BLANKET OR DUCiBO RD AS CALLED FOR ON DRAWINGS. MINIMU 3'-O" TO FIRS BRANCH OR ELBIW 05 SYM FLEXIBLE DUCT PROVIDE 1/4" BEAD AROUND COLLAR FOR CLAMP CATCH SMACNA APPROVED CLAMP NOTE: 1. FLEXIBLE DUCT TO DIFFUSERS SHALL NOT BE USED ABOVE NON - REMOVABLE HARD CEILINGS. USE RIGID DUCT CONNECTIONS. 2. ACOUSTIC LINING ONLY REQUIRED AT CONFERENCE ROOMS. SCALE: NONE DUCT ELBOWS CHANGE OF DUCT SIZE REVISION TRANSITION DIFFUSER NECK SIZE +2" BOTH SIDES TURNING VANES CONICAL SPIN -IN OR TRANSITION TO CONNECTION END TAP SIZE AT LEAST 50% GREATER THAN AREA OF SMALLER DUCT BY PLAN 12 "x12" ACCESS PANEL ON BOTTOM OF DUCT UPSTREAM OF TURNING VANES. REQUIRED FOR RETURN AND EXHAUST DUCTS R=1 /2W DUCTS W/ AIR VELOCITY UNDER 1,500 FPM R =W DUCTS W/ AIR VELOCITY OVER 1,500 FPM AND ALL DUCTS UPSTREAM OF TERMINAL UNITS DIFFUSER DIFFUSER NECK SIZE REFER TO DRAWINGS/ SPECIFICATIONS FOR TYPE AND SIZE ELEVATION TYPICAL DIFFUSER CONNECTION n dy.sos APPROVED DIFFUSER DIMENSION TO SUIT CEILING PLENUM. MINIMUM TO BE DUCT CONNECTION SIZE +2" OFFSETS NOTE: OFFSETS (TO AVOID OBSTRUCTIONS) ARE REQUIRED BUT ARE NOT NECESSARILY SHOWN ON THE PLANS. DATE SQUARE OR ROUND DIFFUSER NECK. REFER TO DRAWINGS/ SPECIFICATIONS FOR TYPE AND SIZES. DIFFUSER BOOT W/ 1" ACOUSTIC LINING STRAP HANGER WHERE REQUIRED DIFFUSER BOOT W/ 1" FIBER -FREE ACOUSTIC LINING SHEETMETAL BAFFLE INSIDE CEILING MAX. 1'5' 45" OR 90° RADIUS ELBOWS OBTAIN PRIOR APPROVAL FOR ALL RETURN & EXHAUST LOCATIONS TURNING VANES ACCESS PANEL (TYPICAL REQUIRED FOR RETURN & EXHAUST DUCTS NOT LESS THAN TWICE THE DUCT AREA DUCT FITTING REQUIRE SCALE: NONE FLEXIBLE DUCT =45 ROUND OR RECTANGULAR - 1 W I--.- —1W I-- R=1/2W DUCTS W/ AIR VELOCITY UNDER 1,500 FPM R =W DUCTS W/ AIR VELOCITY OVER 1,500 FPM AND ALL DUCTS UPSTREAM OF TERMINAL UNITS DENTS (T) ai505 g LAS OE / N6 4V U STRAP STRAP HANGER HANGER 8" MINIMUM INSIDE RADIUS I PROVIDE 1 /4" BEAD BEAD AROUND COLLAR FOR CLAMP CATCH SMACNA APPROVED CLAMP EARTHQUAKE SUPPORT WIRES WHERE REQUIRED NOTE: DIRECT CONNECTION OF FLEXIBLE DUCT TO DIFFUSER (WITHOUT DIFFUSER PLENUM) WILL BE ALLOWED ONLY WHEN SUFFICIENT VERTICAL CLEARANCE IS AVAILABLE TO MEET THE REQUIREMENTS SHOWN. TYPICAL DIRECT DIFFUSER CO SCALE: NONE THE FOLLOWING DUCT FITTINGS ARE CONSIDERED ACCEPTABLE. THE CONTRACTOR SHALL OBTAIN ENGINEER'S APPROVAL FOR OTHER FITTINGS PRIOR TO FABRICATION. ONLY FITTINGS WITH EQUAL OR LOWER PRESSURE DROP WILL BE CONSIDERED. BRANCH DUCT TAKEOFFS W/ MINIMUM PRESSURE DROP P D= OW, BUT NOT MORE THAN 12" (1/3W OK IF UNDER 3,000 FPM) OK ONLY UNDER 1,500 FPM OK ONLY UNDER 1,500 FPM RECTANGULAR DUCT CONICAL SPIN-IN ROUND DUCT RUNOUT TO SINGLE DIFFUSER OR GRILLE ONLY ACCESS PANEL AIR EXTRACTOR ADJUSTABLE FROM OUTSIDE DUCTWORK. OBTAIN PRIOR APPROVAL FOR ALL RETURN AND EXH. LOCATIONS ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. \INECTION n j505 DATE 12" MINIMUM STRAIGHT VERTICAL DUCT ADAPTER WHEN REQUIRED CEILING DIFFUSER REFER TO DRAWINGS, SCHEDULES SPECIFICATIONS FOR TYPE AND SIZE DRAWN COFFMAN M.SOTURA ENGINEER CHECKED APPROVED APPROVED ISSUE FOR PERMIT DATE 01.15.07 01.15.07 SUBTITLE TITLE MECHANICAL MASTER CONICAL SPIN -IN (MIN. 2" LARGER) AIRFLOW TYPICAL CON , NOTE: 1. DO NOT UTILIZE FLEXIBLE DUCT IF NOT INDICATED ON PLANS. PROVIDE SHEETMETAL DUCT, RECTANGULAR IF NEEDED FOR SPACE CONSTRAINTS. 2. COLLAR CONNECTIONS ARE NOT PERMITTED. FOR DIFFUSERS A SCALE: NONE AcOFFMAN GIN EE RS 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 HVAC DETAILS 9 -90 RENOVATION BUILDING 9 -90 TRUNK DUCT NOT LESS THAN ONE STRAP HANGER FOR EACH FLEX DUCT ECTING DUCT DEV. CENTER,WA \D GRILLES n �M505 DIFFUSER OR GRILLE (TYP). REFER TO ACCEPTABLE CONNECTION DETAILS CURRENT REVISION SHEET JOB NO. DWG NO. - (3) ACCEPTABLE ROUND DUCT TAKE -OFFS PROVIDE A VOLUME DAMPER FOR EVERY DIFFUSER AND GRILLE. LOCATE DAMPER AS FAR AS PRACTICAL, AND WITH NOT LESS THAN 6 LINEAR FEET OF DUCT, FROM DIFFUSER OR GRILLE. LOCATE DAMPERS ON RECORD DRAWINGS AND COORDINATE WITH AIR BALANCER 6 FOOT MINIMUM, 8 FOOT MAXIMUM LENGTH AND 180' MAXIMUM CUMULATIVE CHANGE OF DIRECTION FOR FLEX DUCT. PROVIDE AT LEAST 90' CHANGE OF DIRECTION WHERE POSSIBLE FOR ACOUSTICAL CONSIDERATION s 'oRic M505 150680 -01 9- 90 -M505 DATE COMP NO. mem cliv JK APR 0 9 2007 PERMIT C•EN (!", t 04.05.07 t . • r 0• 1 CEILING 1/4" WIRE MESH SCREENED OPENING NOTES: 1. RETURN AIR BOOT SHALL BE CONSTRUCTED OF SHEET META_ WITH 1" RIGID FIBER -FREE SOUND LINING. DUCT DIMENSIONS SHALL EQUAL NOMINAL GRILLE DIMENSIONS. I 2. DIMENSION "L" SHALL BE 2' -0" MINIMUM, OR MORE AS RE{ UIRED TO PREVENT "LINE OF SIGHT" NOISE PATH. DIMENSION "L" CA BE MEASURED FROM EITHER LEG OF BOOT. 3. WHERE VISIBLE FROM FLOOR LEVEL, PAINT DUCT EXTERIOR PAINT SELECTED BY ARCHITECT. TYPICAL RETURN /TRANSFER GRILLE SCALE: NONE 62x16 COMPUTER ROOM AIR CONDITIONER (CRAC) UNIT 42x16 RAISED FLOOR 12" LIGHT CLEARANCE FACTORY UNIT SUPPORT STAND AC1E10 & AC1F10 SCALE NONE SUPPORT DUqT BOOT , r FROM STRUCTURE WITH STRAPS OR HANGERS NITH FACTORY SUPPLIED FLOOR STAND WITH TURNING VANE ,> w/BooT n NP M506 WALL MOUNTED TRANSFER GRILLE, MOUNT BOTTOM OF GRILLE BETWEEN 9'--6" AFF AND 10' -0" AFF NP M506 1/4" WIRE MESH SCREENED OPENING SYM ORIC REVISION BY APPROVED SLOT DIFFUSER SCALE: NONE NOTES: 1. RETURN AIR BOOT SHALL BE CONSTRUCTED OF SHEET METAL WITH 1" RIGID FIBER -FREE SOUND LINING. DUCT DIMENSIONS ON PLANS ARE INSIDE DIMENSIONS. 2. DIMENSION "L" SHALL BE 2' -O" MINIMUM, OR MORE AS REQUIRED TO PREVENT "LINE OF SIGHT" NOISE PATH. DIMENSION "L" CAN BE MEASURED FROM EITHER LEG OF BOOT. 3. WHERE VISIBLE FROM FLOOR LEVEL, PAINT DUCT EXTERIOR WITH PAINT SELECTED BY ARCHITECT. TYPICAL RETURN /TRANSFER w/BooT SCALE: NONE DATE BEAM CLAMP W /RETAINING CLIP, PER SMACNA DUCT CONSTRUCTION STD, FIGURE 4 -2 V A THREADED ROD, 2 --- - -, PER DIFFUSER I- J rir��� : :arAirAn�i OVAL INLET vIOUNTING DETAIL AiratE7AW® SLOT DIFFUSER AND PLENUM. MOUNT BOTTOM AT 9'6 "AFF WHERE NEAR CEILING TILE. MOUNT AS HIGH AS POSSIBLE WHERE IN AREAS WITHOUT CEILING SUPPORT DUCT BOOT 4( -- FROM STRUCTURE WITH STRAPS OR HANGERS 36" LONG CHANNEL. ATTACH TO SLOT DIFFUSER IN 4 PLACES WHERE VISIBLE FROM BELOW, GALV SHT MIL DUCTWORK Sc SLOT DIFFUSER SHALL BE PAINTED AS PER ARCHITECT COLOR SELECTION. WHERE ABOVE CEILING, & NOT VISIBLE FROM 7 .-I--- BELOW, DUCTWORK SHALL BE EXTERNALLY INSULATED LAY -IN CEILING (44- TYP M506 APPROVED BY 1/4" WIRE MESH SCREENED OPENING ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. ISSUE FOR PERMIT DATE DRAWN COFFMAN CHECKEb M.SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTITLE TITLE MECHANICAL MASTER AFOFFMAN G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 HVAC DETAILS 9 -90 RENOVATION BUILDING 9 -90 DEV. CENTER,WA CURRENT REVISION SHEET JOB NO. DWG NO. M506 150680 -01 SYMBOL 9- 90 -M506 DATE CITY OF T, 1 APR 0 9 2007 COMP NO. PER,1p mow. 04.05.07 F. I 'I 'f SCALE: NONE OVERLAPPING GALVANIZED SHEET METAL PROTECTION SHIELD PROTECTION SADDLE STEA INSULATION INSERTED IN SADDLE CAVITY CEILING SCALE: NONE PIPE HANGERS-INSULATED PIPE DETAIL SCALE: NONE — M5 AUTOMATIC AIR VENT PETES PLUG (TYP) 1/2" —� 1 +: TRAP PRIMER RAISED FLOOR COMPUTER Roo V RAISED FLOOR DETAIL 'A' HOT PIPE 4" DIAMETER AND LARGER (60° F& HIGHER) 1/2"CW FOR HUMIDIFIER (NO RPBP REQ'D) LOW POINT DRAIN W/ HOSE CONNECTION REVISION V —s TO PENTHOUSE THREAD --O —LET 2" BY —PASS GATE VALVES MECH RM 11V6 FLR HANGER ROD W/ JAM NUT 6" STEAM SUPPLY SHUT -OFF VALVE DE AIL j 5O8 CLEVIS HANGER PIPE INSULATION CUT TO FIT AROUND PROTECTION SADDLE OVERLAPPING GALVANIZED SHEET METAL PROTECTION SHIELD DOUBLE THICKNESS JACKET BOTTOM vi AIR CONDITIO cp 1 -cp STRAINER COIL RUNOUT DRAIN W/ HOSE CONNECTION. LOCATE © LOW POINT CONNECTION OF RUNOUT PIPING COMPUTER ROOM AIR CONDITIONER (CRAC) HWS I! — ROUTE PIPING GROUP ON HORIZONTAL PLANE OUNTED CHILLED WATER ETAIL 'B' ER PIPING DIAGRA DATE SYM BALL VALVE I S CHWR HANGER ROD WI JAM NUT CLEVIS HANGER PIPE INSULATION — UPPER HALF OF PIPE HIGH DENSITY INSULATION INSERT — LOWER HALF OF PIPE -1OT PIPE UNDER 4" DIAMETER COLD PIPE ALL SIZES vi mat I CRAC UNIT FLOOR STAND BY MFR 1/2" 1 -1 /4 "CONDENSATE DRAIN SLOPE 1 /4 " /FT 1" CONDENSATE DRAIN REVISION ( — M508 BY APPROVED DRAIN PANS (TYP.) DATE SCALE: NONE CHWS CHWR INDIRECT DRAIN TO COLLECTOR PIPE OR APPROVED RECEPTOR, ONE PIPE SIZE LARGER THAN CONNECTION SIZE TO F.D. PROVIDE OVERFLOW CONDENSATE DRAIN WITH TRAP WHERE CONNECTION IS PROVIDED WITH UNIT, PROVIDE DRAIN CONNECTION TO SEPARATE DRAIN PAN (WITHOUT TRAP) OTHERWISE g i BOE /NG � DRAIN PAN 1/2" FOR VENTING • i r ' EXPIRES 1/10/09 DRAIN PAN CONNECTION APPROVED BY „ If DEPT. If D f- AUXILIARY AIR CONDITIONING EQUIPMENT PREFERRED TRAP LOCATION AT UNIT 5 „ CEILING MOUNTED CHILLED WATER COvIPUTER ROOFV COOLING UNIT PIPING DIAGRAV n SCALE: NONE — I M500 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DATE DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED BAL. VALVE (TYP) SAME SIZE AS HEADER CONN. (TYP) 2 —WAY PRESSURE INDEPENDANT CONTROL VALVE (TYPICAL) BLOCK COIL REMOVAL CHILLED WATER COIL PIPING DIAGRAM( AHU -1 & AHU -3) CONDENSATE PUMP FURNISHED WITH SOME UNITS r e -- PROVIDE DRAIN PAN UNDER UNIT WITH LEAK DETECTOR PROVIDE GRAVITY CONDENSATE DRAIN WITH TRAP OR PUMPED CONDENSATE DRAIN AS APPLICABLE FOR UNIT. DATE 01.15.07 01.15.07 MEMORY STOP `CH[LLED WATER RETURN XI CHILLED WATER SUPPLY -LOCATE RISERS SO AS TO NOT c 1/2" DRAIN AT LOWEST HEADER (FLOW OR RETURN) ISSUE FOR PERMIT SUBTITLE E TITLE MECHANICAL MASTER THREADED CAP FOR PRIMING & CLEANOUT (TYP) TO FLOOR DRAIN A (TYP) COOLING coin con SCALE: NONE PIPING DETAILS 9 -90 RENOVATION BUILDING 9 -90 LEGE VD ACOF F AN N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101-1625 206 623 0717 Fax 206 624 3775 REVIEWED FOR OBOE COMPLIANCE �~�'® Mp MR( 2 4 2001 CO Of Tuk a IRAN .. 1. SLOPE ALL DRAIN PIPING PER CODE, BUT NEVER LESS THAN 1 %. DEV. CENTER,WA SHEET DWG NO. TEST PLUG BALL VALVE GATE VALVE 2 —WAY CONTROL VALVE BUTTERFLY VALVE GATE VALVE WITH HOSE CONNECTION AUTOMATIC FLOW CONTROL VALVE GENERAL NOTES WYE STRAINER (W/ DRAIN VALVE) THERMOMETER UNION AUTOMATIC AIR VENT (WITH DRAIN) REFERENCE DRAWINGS CONSTRUCTION NOTES FROM AIR HANDLER B (TYP) ORIG 9 -90 RENOVATION J11150680 -01 BY COFFMAN APPROVED M.SOTURA 04.05.07 2. TRAP DEPTH DIMENSION "A" SHALL BE THE MAXIMUM POSSIBLE NEGATIVE PRESSURE IN THE UNIT AT THE DRAIN OUTLET (IN INCHES W.G.) PLUS ONE INCH. IF THE PRESSURE IS POSITIVE, " A " SHALL BE ONE INCH. 3. TRAP DEPTH DIMENSION "B" SHALL BE HALF OF "A" PLUS ONE INCH IF OUTLET IS UNDER NEGATIVE PRESSURE. IF THE PRESSURE IS POSITIVE, "B" SHALL BE THE MAXIMUM POSSIBLE PRESSURE (IN INCHES W.G.) PLUS TWO INCHES. DE\SATE TRAP D Jj5O8 CURRENT REVISION M508 JOB NO. 150680-01 s 'ORIG 9-90—M508 DATE RECi ETV ern' c r 1 APR 0 9 2001 PERMIT COMP NO. 04.05.07 4" STEAM SEPARATOR 0 -200 PSI SHUT -OFF VALVE (TYPICAL) 4" SCALE: NONE STEAJ CO\ SCALE: NONE 1 -1/2" 0- . 3" R 3/4" 1~°4 THERMODYNAMIC TRAP 250 LBS /HR 4" VENT TO ATMOSPHERE OVERFLOW FROM PRV 0 -60PSI Q X STEAM SEPARATOR 3' STEA V1 SCALE: NONE V L 1 / t-- z w PRESSURE POWERED PUMP PRV -1 I PRV -2 w a 4 1I RECEIVER CONDENSATE LOW PRESSURE STEAIV PRV DETAIL (PE 3" CONDENSATE MIN. 10 PIPE DIAMETERS OF STRAIGHT PIPE 4" 3/4" FLOAT & THERMOSTATIC STEAM TRAP 4" CONDENSATE RETURN I 1", 60 PSI MOTIVE STEAM VD AI N PRESSURE POWERED PUMP DENSATE PUMP PAC NOTE: PIPE SIZES ARE FOR PACKAGE CPP-1B. SEE DETAIL MIN. 15 STRAIGH 6" ETER INSTALLAT 2 ON 1M452 FOR CPP -1A PIPE SIZES <AGE DETAIL (741- 1M452 M509 FT OF PIPE STEAM METER t PRESSURE GAGE, W/ PIGTAIL AND SHUT -OFF VALVE, TYPICAL 0-60 PSI RELIEF VALVE, 6" VTR, 12,000 LB /HR DISCHARGE PIPE TO DRIP PAN ELBOW 15 PSIG REDUCED PRESSURE STEAM PRESSURE REDUCING VALVE 3" INLET, 6" OUTLET THOUSE) PIM450 M509 COMP AIR- - 3/4" 1/2 v ❑ THERMO DYNAMIC TRAP 2" 2-1/2" TO CONDENSATE RETURN vi MIN. 4 FT OF STRAIGHT PIPE 6" ION DETAIL P1M450 M509 FLOAT & THERMOSTATIC STEAM TRAP STEAM SEPARATOR 0 -200 PSI SHUT -OFF VALVE (TYPICAL) 3/4" MEDIUEV SCALE: NONE 15 PSI STEAM SEE SIZES ON PENTHOUSE DWGS N STEAM CONTROL VALVE SEPARATOR T 2" FOR HC-1 & HC -3 2-1/2" FOR HC-2 & HC -4 CO DATE 04.05.07 z STEA SCALE: NONE STEAV SCALE: NONE THERMODYNAMIC TRAP 60 LBS /HR PRESSURE STEA - -flv- -I N COIL WITH PUMP TRAP PACKAGE DETAIL (5 1 P1M450,P1 k451 M509 SAFETY RELIEF VALVE 4 3/4" RECEIVER CONDENSATE INLET l PRV -3 CONDENSATE CL V DIRT LEG I C4 I THERMO DYNAMIC TRAP NIPPLE, 9" LONG TO PIPING g LararAF - Ardifig ® - (_, MIN. 10 PIPE DIAMETERS OF STRAIGHT PIPE PUMP TRAP 1 " 1" PRV DETAIL ( CHECK VALVE 3/4" VENT TO OUTDOOR 1" CLEAR AIR GAP V ■ VENT 1 /2 "STM SAFETY VALVE DISCHARGE ELBOW WASTE TO OPEN DRAIN SAFETY RELIEF VALVE (PSV) DISCHARGE DETAIL n ivaso PRESSURE GAGE, W/ PIGTAIL AND SHUT-OFF VALVE, 0 -100 PSI RELIEF VALVE, 1 "VTR, 1,000 LB /HR DISCHARGE PIPE TO DRIP PAN ELBOW 60 PSIG REDUCED PRESSURE STEAM PRESSURE REDUCING VALVE 3/4" INLET, 1" OUTLET ECH. RM. 11V6) � 7M452 M509 CONDENSATE RETURN LINE 15 PSI y MOTIVE STEAM APPROVED BY FLOAT & THERMOSTATIC STEAM TRAP ACCEPTABILITY TH }S DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTITLE TITLE ISSUE FOR PERMIT MECHANICAL MASTER THREE TURN SWIG JOINT DETAIL SCALE: NONE THERMOSTATIC AIR VENT AT END OF MAIN AND AT PRV STATIONS c_r__ ______----- PROVIDE FULL SIZE DRIP LEG AT END .,� OF MAIN OR AT RISER h L ELEVATION VIEDIUN PRESSURE DRIP LEG AND TRAP DETAIL ( SCALE: SCALE: NONE ( DRIP LEG TO BE LINE SIZE GATE VALVE TYP UNION STRAINER TYP F } II NC ' EQUIPMENT CONNECTION 3/4" FREE BLOW DRIP LEG MAIN STEAM LINE L 4 Coil GV LOW PRESSURE DRIP LEG A SCALE: NONE N FFM G I N E E K S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 --1625 206 623 0717 Fax 206 624 3775 STEAM SYSTEM DETAILS 9 -90 RENOVATION BUILDING 9-90 THERMO DYNAMIC TRAP DRIP LEG H " SCH. 80 TO DRAIN 1" SCH. 80 ( STRAINER UNION TO EQUIPMENT 1/2" BLOWDOWN REVIEWED fOR COM. COMPLIANCE APPROVED Ma's 4VII • Qi lukt tea I1_oI DEV. CENTER,WA NOTE: PIPING TO TURN IN TWO PLANES. OFFSETS TO BE BX DIA., 6" MINIMUM CHECK SIZE AS INDICATED VALVE ON PLANS GV D TRAP DETAIL ( M509 CURRENT REVISION SHEET (3 jj5O9 M509 JOB NO. 150680 -01 DWG NO. CONNECT TO TOP OF CONDENSATE MAIN FLOAT & THERMOSTATIC STEAM TRAP TO COND. RETURN MAIN SYMBOL^ R I G 9- 90 -M509 RECEIVED OF T«KW1.1A APR 0 9 2007 PERMIT CEN T Cri DATE 04.05.07 COMP NO. j nor r TA-e --- ce - s - sT DOOR I I 1 I I I I I • I \/0/\ - DOOR L_J I A . ; . \ F 5 'DOOR I I I I I I I I t t FAN GUARD . x CD 12" FINAL FILTERS 96 x 108 ( • c (1) STEAM COIL HC -2 I DOOR I .11N. x CQ 2" PRE-FILTERS 96 x 108 (1) z r I II DOOR . �e r a ihwla[o1111 . - - -- - "-. — --- — - - • �_;nwr y m I l i I I I �1-. II �i i ir I ( ! LL L Jl�trir 5-2 ■ li MIME i1 FF t I J�I�1 /� ._-....w. w _. ........... 1 ®1 ci I D I A .., —-- - - -- -. ee - - J j nor r TA-e --- ce - s - sT DOOR I I 1 I I I I I • I \/0/\ - DOOR L_J I \ F 5 'DOOR I I I I I I I t FAN GUARD . \ o / i�; la .. .. I DOOR I IFACCESS z I II DOOR y m I l i I I I I ( ! LL L Jl�trir t I I 1 ®1 I —-- - - -- -. ee - - J k. a.- J �_J�. L FAN GUARD SYM oo 0 A /D A/D 24W X 66H 24W X 66H DEMOUNT = 96 /D( 24W X 66H A /D(4) 30W X 66H PLAN VIEW UNIT LENGTH = 295 2" 20ga Solid Galy. = 295 DEMOUNT = 84 .1 w 36 --I 24 I-- 36 --I 24 AHU -3 COLD DECK DETAIL SCALE: ,fir = Y_o" 60 RIGHT GLL VA TION Mu DEMOUNT = 115 114 SO A/D TOSL(5) 30W X 66H MAIN DISCON. AUUL DOOR ORIG 9 -90 RENOVATION REVISION BY APPROVED J4150680 -01 COFFMAN M.SOTURA DATE 03.01.07 SYM REVISION BY LEFT SIDE O op RIGHT SIDE " FLANGE 0 N APPAPPE7A(® A /D(1) A /D(2) A /D(3) A /D(4) 24W X 6 1 24W X 6 -1 24W X 6 OW X 66H PLM 1 yew UNIT LENGTH = 236 2" 20ga Solid GaIv. = 236 36 D PIKES 1 /10 /09 36 --I 24 I--- 48 ACCEPTABILITY TI-115 DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. RIGHT ELEVATION' AHU -4 HOT DECK DETAIL DATE DRAWN COFFMAN CHECKED M.SOTURA ENGINEER CHECKED APPROVED APPROVED DATE 01.15.07 01.15.07 SUBTf.E TITLE M VFD 90 ISSUED FOR CONSTRUCTION MECHANICAL MASTER �- MAIN DISCON. A/D TOSL(5) $# 30W X 66H 9 -90 RENOVATION BUILDING 9 -90 LEFT SIDE RIGHT SIDE N �OFFMAN 6 NEE RS N G I N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 AIR HANDLING UNIT DETAILS 1" FLANGE REVIEWED FOR. P CODE. CO ADD APP Mpi 2A. 70 ILO VISO DEV. CENTER,WA CURRENT REVISION SHEET JOB NO. DWG NO. M510 150680 -01 sY " BOL QRIG 9- 90 -M510 FtEcErviso LA APR 0 9 2007 DATE COMP NO. 03.01.07 • I I I I I l 1s { c c ,, 9 -90 RE AL(L. DOOR J #150680 -01 FAN GUARD COFFMAN M.SOTURA FAN GUARD 03.01.07 Mel IZI FLANGE LEFT SIDE 5 v 0 0 11 • x H RIGHT SIDE REVISION (5)A /D TOSLU# 30W X 66H MAIN DISCON. DEMOUNT = 115 114 BY APPROVED AHU -1 SCALE: 1 /2 "= DATE SYM (4)A7 3DW X 66H A/D 24W X 66H 24W X 66H 24W X 66H PLAN` MEW GIR] UNIT LENGTH = 295 2" 20ga Solid Galy. = 295 DEMOUNT = 84 -- COLD DECK DETAIL (Th —0" M51 OA REVISION DEMOUNT = 96 60 -I 24 I--- 36 --I 24 I.-- 36 --I MOHT ELEVATION BY APPROVED DATE N GUARD 1 co 1 FLANGE LEFT SIDE } RIGHT SIDE EXPIRES 1/10/09 MAIN DISCON.-- (5)A /D TOSL 30W X 66H sti rci 90 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 2" 20ga Solid Galy, = 236 DATE PLAN WEN! UNIT LENGTH = 236 NWT IT ELENAT!O 8 DRAWN COFFMAN CHECKED M.SOTURA 'ENGINEER CHECKED APPROVED APPROVED (4)A /D (3)A /D (2)A /D (1)A /D 30W X 66F n 2,4W X 66H 2,4W X fib .03=1111 24W X 66H 48 --I 24 1' AHU-2 HOT DECK DETAIL (7' SCALE: , /z ° = ,'—o ISSUED FOR CONSTRUCTION DATE 01.15.07 01.15.07 SUBTITLE M51 OA MECHANICAL MASTER 36 --I 9 -90 RENOVATION BUILDING 9 -90 co O A CO F FMA N N G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 AIR HANDLING UNIT DETAILS DEV, CENTER,WA CURRENT REVISION SYMBOL() R 1 SHEET M5IOA SHEET JOB NO. DWG NO. COD COMP APPRO tk'2. 21 CM 150680 -01 9- 90 —M510A RECEIVED 'Y TI!w'..n1 A 'APR 0 9 2007 PERM.'' DATE 03.01.07 COMP NO. r DI h ',I u . � . T — FAN GUARD \ _ .T. _-. _ 4 I A4 1W1 : 4 i \ ? OOR .--� ti .9 o \70/\ Uan X CO d7 1 I 03 CO I J s v �i�ckQ; F- Ln �_ - �;91III! — - — 1 I I I II . i i. _ _ a I S -4 I 11MI I II ,,..,. 1 1 I II I ? � III — , I 1 I I I _ I � 1 I I L I 9 -90 RE AL(L. DOOR J #150680 -01 FAN GUARD COFFMAN M.SOTURA FAN GUARD 03.01.07 Mel IZI FLANGE LEFT SIDE 5 v 0 0 11 • x H RIGHT SIDE REVISION (5)A /D TOSLU# 30W X 66H MAIN DISCON. DEMOUNT = 115 114 BY APPROVED AHU -1 SCALE: 1 /2 "= DATE SYM (4)A7 3DW X 66H A/D 24W X 66H 24W X 66H 24W X 66H PLAN` MEW GIR] UNIT LENGTH = 295 2" 20ga Solid Galy. = 295 DEMOUNT = 84 -- COLD DECK DETAIL (Th —0" M51 OA REVISION DEMOUNT = 96 60 -I 24 I--- 36 --I 24 I.-- 36 --I MOHT ELEVATION BY APPROVED DATE N GUARD 1 co 1 FLANGE LEFT SIDE } RIGHT SIDE EXPIRES 1/10/09 MAIN DISCON.-- (5)A /D TOSL 30W X 66H sti rci 90 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 2" 20ga Solid Galy, = 236 DATE PLAN WEN! UNIT LENGTH = 236 NWT IT ELENAT!O 8 DRAWN COFFMAN CHECKED M.SOTURA 'ENGINEER CHECKED APPROVED APPROVED (4)A /D (3)A /D (2)A /D (1)A /D 30W X 66F n 2,4W X 66H 2,4W X fib .03=1111 24W X 66H 48 --I 24 1' AHU-2 HOT DECK DETAIL (7' SCALE: , /z ° = ,'—o ISSUED FOR CONSTRUCTION DATE 01.15.07 01.15.07 SUBTITLE M51 OA MECHANICAL MASTER 36 --I 9 -90 RENOVATION BUILDING 9 -90 co O A CO F FMA N N G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 AIR HANDLING UNIT DETAILS DEV, CENTER,WA CURRENT REVISION SYMBOL() R 1 SHEET M5IOA SHEET JOB NO. DWG NO. COD COMP APPRO tk'2. 21 CM 150680 -01 9- 90 —M510A RECEIVED 'Y TI!w'..n1 A 'APR 0 9 2007 PERM.'' DATE 03.01.07 COMP NO. r DI h ',I u . FAN GUARD \ • 4 \ / ¢ : 4 \ ? OOR .--� ti - o \70/\ r =4j 9 -90 RE AL(L. DOOR J #150680 -01 FAN GUARD COFFMAN M.SOTURA FAN GUARD 03.01.07 Mel IZI FLANGE LEFT SIDE 5 v 0 0 11 • x H RIGHT SIDE REVISION (5)A /D TOSLU# 30W X 66H MAIN DISCON. DEMOUNT = 115 114 BY APPROVED AHU -1 SCALE: 1 /2 "= DATE SYM (4)A7 3DW X 66H A/D 24W X 66H 24W X 66H 24W X 66H PLAN` MEW GIR] UNIT LENGTH = 295 2" 20ga Solid Galy. = 295 DEMOUNT = 84 -- COLD DECK DETAIL (Th —0" M51 OA REVISION DEMOUNT = 96 60 -I 24 I--- 36 --I 24 I.-- 36 --I MOHT ELEVATION BY APPROVED DATE N GUARD 1 co 1 FLANGE LEFT SIDE } RIGHT SIDE EXPIRES 1/10/09 MAIN DISCON.-- (5)A /D TOSL 30W X 66H sti rci 90 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 2" 20ga Solid Galy, = 236 DATE PLAN WEN! UNIT LENGTH = 236 NWT IT ELENAT!O 8 DRAWN COFFMAN CHECKED M.SOTURA 'ENGINEER CHECKED APPROVED APPROVED (4)A /D (3)A /D (2)A /D (1)A /D 30W X 66F n 2,4W X 66H 2,4W X fib .03=1111 24W X 66H 48 --I 24 1' AHU-2 HOT DECK DETAIL (7' SCALE: , /z ° = ,'—o ISSUED FOR CONSTRUCTION DATE 01.15.07 01.15.07 SUBTITLE M51 OA MECHANICAL MASTER 36 --I 9 -90 RENOVATION BUILDING 9 -90 co O A CO F FMA N N G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 AIR HANDLING UNIT DETAILS DEV, CENTER,WA CURRENT REVISION SYMBOL() R 1 SHEET M5IOA SHEET JOB NO. DWG NO. COD COMP APPRO tk'2. 21 CM 150680 -01 9- 90 —M510A RECEIVED 'Y TI!w'..n1 A 'APR 0 9 2007 PERM.'' DATE 03.01.07 COMP NO. r DI h ',I u . FAN GUARD \ 4 \ / ¢ : 4 \ ? OOR .--� ti - o \70/\ r =4j ACCESS H I F- 1 I I I II I I I II ,,..,. 1 1 I II I !�, — , I 1 I I I h >r norm 1 I I L I I I — — - L__J Lcy1. - 1L_J _J _ 3 9 -90 RE AL(L. DOOR J #150680 -01 FAN GUARD COFFMAN M.SOTURA FAN GUARD 03.01.07 Mel IZI FLANGE LEFT SIDE 5 v 0 0 11 • x H RIGHT SIDE REVISION (5)A /D TOSLU# 30W X 66H MAIN DISCON. DEMOUNT = 115 114 BY APPROVED AHU -1 SCALE: 1 /2 "= DATE SYM (4)A7 3DW X 66H A/D 24W X 66H 24W X 66H 24W X 66H PLAN` MEW GIR] UNIT LENGTH = 295 2" 20ga Solid Galy. = 295 DEMOUNT = 84 -- COLD DECK DETAIL (Th —0" M51 OA REVISION DEMOUNT = 96 60 -I 24 I--- 36 --I 24 I.-- 36 --I MOHT ELEVATION BY APPROVED DATE N GUARD 1 co 1 FLANGE LEFT SIDE } RIGHT SIDE EXPIRES 1/10/09 MAIN DISCON.-- (5)A /D TOSL 30W X 66H sti rci 90 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. 2" 20ga Solid Galy, = 236 DATE PLAN WEN! UNIT LENGTH = 236 NWT IT ELENAT!O 8 DRAWN COFFMAN CHECKED M.SOTURA 'ENGINEER CHECKED APPROVED APPROVED (4)A /D (3)A /D (2)A /D (1)A /D 30W X 66F n 2,4W X 66H 2,4W X fib .03=1111 24W X 66H 48 --I 24 1' AHU-2 HOT DECK DETAIL (7' SCALE: , /z ° = ,'—o ISSUED FOR CONSTRUCTION DATE 01.15.07 01.15.07 SUBTITLE M51 OA MECHANICAL MASTER 36 --I 9 -90 RENOVATION BUILDING 9 -90 co O A CO F FMA N N G 1 N E E R S 1601 Fifth Avenue Suite 900 Seattle, Washington 98101 -1625 206 623 0717 Fax 206 624 3775 AIR HANDLING UNIT DETAILS DEV, CENTER,WA CURRENT REVISION SYMBOL() R 1 SHEET M5IOA SHEET JOB NO. DWG NO. COD COMP APPRO tk'2. 21 CM 150680 -01 9- 90 —M510A RECEIVED 'Y TI!w'..n1 A 'APR 0 9 2007 PERM.'' DATE 03.01.07 COMP NO. r DI h ',I u .