Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-093 - GACO WESTERN PAINT
GACO WESTERN PAINT 18700 SOUTHCENTER PY EXPIRED 10 -29 -07 M07 -093 Parcel No.: 3523049014 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: City -if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 18700 SOUTHCENTER PY TUKW GACO WESTERN PAINT 18700 SOUTHCENTER PY , TUKWILA WA Contact Person: Name: JIM MACK Address: PO BOX 885 , PRESTON WA Contractor: Name: INDUSTRIAL PAINT MACHINERY INC Address: PO BOX 885 , PRESTON WA Contractor License No: INDUSPM946QM MECHANICAL PERMIT GACO WESTERN INC PO BOX 88698 TUKWILA STATION , SEATTLE WA DESCRIPTION OF WORK: REPLACE EXISTING EXHAUST SYSTEM WITH REBUILT FAN AND BAGHOUSE Value of Mechanical: $18,866.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wa1L/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 1 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 EOUIPMENT TYPE AND OUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 503 -1675 Phone: 425 222 -6055 Expiration Date: 11/14/2008 M07 -093 05/02/2007 10/29/2007 Fees Collected: $373.30 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 doc: IMC -10/06 M07 -093 Printed: 05-02 -2007 Permit Center Authorized Signature: governing this work will be complied City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -093 Issue Date: 05/02/2007 Permit Expires On: 10/29/2007 Date: I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinance: , whether specified herein or not. The granting of this permi '• es not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or ape ce o o . I ) - uthorized to sign and obtain this mechanical permit. Signature: Date: Print N ' e: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. doc: IMC /06 M07 -093 Printed: 05-02 -2007 Parcel No.: 3523049014 Address: Suite No: Tenant: 18700 SOUTHCENTER PY TUKW GACO WESTERN PAINT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 11: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -093 ISSUED 04/26/2007 05/02/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: An approved automatic suppression system is required in ducts which convey flammable and combustible materials where the largest cross - sectional diameter is 10 inches or greater. (ref. International Mechanical Code, Section 510.7.) 14: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to M07 -093 Printed: 05-02 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 15: Installation of dust collection systems must comply with the International Mechanical Code, 2003 Edition. 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 M07 -093 Printed: 05-02 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: J "'_' 07 doc: Cond -10/06 M07 -093 Printed: 05-02 -2007 c.ommurnty uevelopmen' ' °partment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: I t 7 5 a uTH C r& Tenant Name: � yrco I- 1 e sre A.1 ,tv°! Property Owners Name:_s,4.... £ Mailing Address: Pt 0 Sox 91( King Co Assessor's Tax No.: 5s2-30 4 / ?2/9 Suite Number: F)/4- Floor: /t// New Tenant: fl .... Yes aii..No 5,-77 City . &C/,t1 State 98138' Zip Name: r./ / 4..t Mailing Address: A 0 s 8F5 Day Telephone: yZ s -AP 3 - 1 ) $� City . E -Mail Address: /1 us ?"/":h-t... ph-0177 +�e - t . L<, . Av t Fax Number: 5/2-5 z22 -( 7) State Zip RMATI for Pl umbing and Gas Piping Company Name: /hup v5 '7aiet -C. J ' # A' ' j i _ 4 ; . , . 4 w y / , v . Mailing Address: 2 z t'vs f18 S PR 6") a A 1, t,./,4 91(0a City State Zip Contact Person: 7. A /41A-c- Day Telephone: q2,5 5 - / 6 75 E -Mail Address: /ivpu57p,,' -c P, -„i✓, £9/2i /L.,,jk / Fax Number: 1 /?S- 2Z 6 ry Contractor Registration Number: INDUS Pert 9 ' Vt 49 &v' Expiration Date: 11- /Y - 2aD y Company Name: Mailing Address: city Day Telephone: Fax Number: State Contact Person: E-Mail Address: Zip Company Name: Mailing Address: Zip Contact Person: E -Mail Address: Q:\Appliations\Penns- Applications On Line\3 -2006 - Permit Appliation.doe Revised: 9 -2006 bh City Day Telephone: Fax Number: State Page 1 of 6 Scope of Work (please provide detailed iformation): • Please ref to Ar Biuletiti* or - fees and<estt mates hee Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. ValVue -❑ .. Reason ❑... Sewer Availability Provided Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ... Construction /Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage If Q:'ApplicaeionsTomis- Applications On Line n -2006 - Permit Application.doc Revised: 9 -2006 bh ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ . . Pavement Cut ❑ .. Looped Fire Line Call before you Dig: 1- 800 -424 -5555 f f ❑ .. Highline ❑ ...Renton ::Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑...Civil Plans (Maximum Paper Size -22 "x34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... f f WO # ❑ ...Temporary Water Meter Size .. f f WO # ❑ ...Water Only Meter Size " f WO # ❑...Deduct Water Meter Size ❑ ...Sewer Main Extension Public Private ❑ ...Water Main Extension Public _ Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip Page 3 of 6 Scope of Work (please provide detailed tr'rormation): Tease refer to ?ublc Works Bulletin #1 for lees ant estimate-sheetr Water District ❑ ...Tukwila 0... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑...Civil Plans (Maximum Paper Size -22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ... Construction /Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control cubic yards cubic yards 0 0 ❑ • ❑ • ❑ ...Backflow Prevention - Fire Protection Irrigation " Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public ❑... ValVue 0... Sewer Availability Provided If QA Applications On Line \3_2006 - Permit Application.doc Revised: 9 -2006 bh .. Abandon Septic Tank .. Curb Cut . Pavement Cut . Looped Fire Line rf Call before you Dig: 1- 800 - 424 -5555 WO # WO # WO# Private Private ❑ .. Highline ❑ .. Renton ❑ ...Renton ❑ ...Seattle ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Deduct Water Meter Size ❑ ...Traffic Impact Analysis ❑...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: city Name: Day Telephone: Mailing Address: city State State Zip Zip Page 3 of 6 Un itTyp -- .. Q t y ..Unit p e r n . _ . , s; ' . w i Y t T3'l '4ty ., Bo e rl ptnpt�e or , ..:Qty'" Fumace<100K BTU Air Handling Unit >10,000 CFM 2 Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind ,MECHANICAL CONTRACTOR Ii`ar+RMATION' Company Name: / fir 9(1%(rf'-(- ?A'IN r l4i1Artf 7 dve Mailing Address: ? 0 at»C 815 P n , LV ?- State S 4) City Contact Person: V t H- E -Mail Address: /AV p rl"Ai j1 L. ...AW Contractor Registration Number: / N ©U s p In ggil 4Dn w r/ Valuation of Mechanical work (contractor's bid price): $ / r , ?f CC Use: Residential: New .... Replacement .... Commercial: New ....0 Replacement .... 0 Day Telephone: 5 4 C ' ,� Fax Number: ,92 222 417 Expiration Date:)(- (tf — Scope of Work (please provide detailed information): p p G/+cg Cy r' � iA- ✓5✓ Cy'S r aArwD,Is Zip Fuel Type: Electric 0 Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q: ApplicationsWorms-Appliationa On Line\3 -2006 - Permit Application.doc Revised: 9 - 2006 bh Page 4 of 6 Fixture Type: " Qty ' Fixture Type: Qty : Fixture Type: ..: " Qty " Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas r1L11 L'11 \L 1J4 1 u, "11\ 7 1%1v111 11 \T 1V1\ — LUU-101 - tV PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:1ApplicationsTonna- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 bh Expiration Date: Page 5 of 6 BUILDING 0 Signature: Mailing Address: p. o ri W City Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: `f 2 -r-07 - Day Telephone: ( 1 Z 5' -- S� 3 — ("-4 98`05 State Zip Date Application Expires: 10(xtia- Date Application Accepted: Q:\Applications\Forms- Applications On Line3-2006 -Permit Application.doc Revised: 9 -2006 bh Staff Initials: Page 6 of 6 Receipt No.: R07 -00687 Payee: INDUSTRIAL PAINT MACHINERY, INC. TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049014 Permit Number: M07 -093 Address: 18700 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 04/26/2007 Applicant: GACO WESTERN PAINT Issue Date: Initials: JEM Payment Date: 04/26/2007 12:37 PM User ID: 1165 Balance: $0.00 Amount Payment Check 22986 373.30 Account Code Current Pmts 000/322.100 304.64 000/345.830 68.66 Total: $373.30 Payment .Amount: $373.30 7556 04/27 9710 TOTAL 373.30 doc: Receiot -06 Printed: 04 -26 -2007 08 -30 -2007 JIM MACK PO BOX 885 PRESTON WA 98050 RE: Permit No. M07 -093 18700 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/29/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Xc: Ter Marshall, it Technician Permit File No. M07 -093 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 - 3665 ACTIVITY NUMBER: M07 -093 DATE: 04 -26 -07 PROJECT NAME: GACO WESTERN PAINT SITE ADDRESS: 18700 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Buinkisgn C Public Works Complete Comments: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 FirePrev LAJ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ ❑ Permit Coordinator ❑ DUE DATE: 05-01 -07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 0529-07 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License INDUSPM946QM Licensee Name INDUSTRIAL PAINT MACHINERY INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602373366 Ind. Ins. Account Id #1 Business Type CORPORATION Address 1 PO BOX 885 Address 2 8221 308TH AVE SE City PRESTON County KING State WA Zip 98050 Phone 4252226055 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/14/2006 Expiration Date 11/14/2008 Suspend Date Separation Date Parent Company Previous License INDUSMCO23PW Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 WESTERN SURETY CO 70074419 11/13/2006 Until Cancelled $12,000.00 11/14/2006 Business Owner Information Name Role Effective Date Expiration Date MCDONOUGH, JIM PRESIDENT 11/14/2006 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= INDUSPM946QM 05/02/2007 4 3 oJ v) 0) a 0 a_ N 66 Deg 03' 50' W Existing Warehouse 79'x49' 3871 SF Property Line Existing Warehouse 47'x109' 5123 SF roposed ucting odif ications Existing Manufacturing 75'x109' 8175 SF Existing Warehouse 79'x109' 8611 SE Existing Manufacturing 79'x60' 4740 SE • "-=3=1 I Existing 2 Story Office 58'x135' 15660 SE Existing Landscaping Property Lin Proposed Location o Torrit Mo Propo Conc Toe of Slope Approximate High Water Mark of Green Rive Existing Landscaping Appr Loca Exis xiriate ion of ing Dike SITE PLAN Scate 1' 20` Parcel Number 3523049014 Legal Description= 352304 14 POR OF GL 6 IN SW 1/4 OF SEC DAF BEG AT PT S 89 -01 -50 E 505.54 FT & N 00 -58 -10 E 313.17 FT FR SW COR OF GL 6 TO TPOB TH S 23 -27 -22 W TO S LN GL 6 TH S 89 -01 -50 E ALG SD S LN TO BANK OF GREEN RIVER TH NLY ALG SD RIVER BANK TAP S 67 -36 -00 E FR TPOB TH N 67 -36 -00 W TO TPOB Plan review approval as subject to is and omission, Approval of c r.c rvdtIon doormats does n the vidauon �c`': / , . � code cc ordlnan� Recdpt Of approved , ._: •t ,d 11 , P , Is Wonder** permialoo SEPARATE PERMIT i;I t JIRED FOR: C Mechanical ❑ rwabing ❑ Gas Pip ng City of Tukwila BUILDING DIVISION SING DIVISION —REVItWED FOR MPLIANCE CODE CO i APPROVED IAY -1 2! 111 Of Tukwila LDIN DP11ST 4 Project Location Vicinity Map Not to scale REPLACEMENT OF EXISTING DUST COLLECTION SYSTEM • North 1 ftAo1cFE • a F -- V J -- 2 S shaft tvatrott :. ;3 Cz 7 C W d cO cO CO d d L d CL L °' C WCh u , S - O (A W U CE l'7 be made Prfor :. m =' O1 . 00 _ I to the .. scope '�Pra.2l cf `--t Ire a r te,.. DATE: 4/23/2007 REVISION: New WR 2 F 2200!1 . - wf i/E+.,ah 4 3 oJ v) 0) a 0 a_ N 66 Deg 03' 50' W Existing Warehouse 79'x49' 3871 SF Property Line Existing Warehouse 47'x109' 5123 SF roposed ucting odif ications Existing Manufacturing 75'x109' 8175 SF Existing Warehouse 79'x109' 8611 SE Existing Manufacturing 79'x60' 4740 SE • "-=3=1 I Existing 2 Story Office 58'x135' 15660 SE Existing Landscaping Property Lin Proposed Location o Torrit Mo Propo Conc Toe of Slope Approximate High Water Mark of Green Rive Existing Landscaping Appr Loca Exis xiriate ion of ing Dike SITE PLAN Scate 1' 20` Parcel Number 3523049014 Legal Description= 352304 14 POR OF GL 6 IN SW 1/4 OF SEC DAF BEG AT PT S 89 -01 -50 E 505.54 FT & N 00 -58 -10 E 313.17 FT FR SW COR OF GL 6 TO TPOB TH S 23 -27 -22 W TO S LN GL 6 TH S 89 -01 -50 E ALG SD S LN TO BANK OF GREEN RIVER TH NLY ALG SD RIVER BANK TAP S 67 -36 -00 E FR TPOB TH N 67 -36 -00 W TO TPOB Plan review approval as subject to is and omission, Approval of c r.c rvdtIon doormats does n the vidauon �c`': / , . � code cc ordlnan� Recdpt Of approved , ._: •t ,d 11 , P , Is Wonder** permialoo SEPARATE PERMIT i;I t JIRED FOR: C Mechanical ❑ rwabing ❑ Gas Pip ng City of Tukwila BUILDING DIVISION SING DIVISION —REVItWED FOR MPLIANCE CODE CO i APPROVED IAY -1 2! 111 Of Tukwila LDIN DP11ST 4 Project Location Vicinity Map Not to scale REPLACEMENT OF EXISTING DUST COLLECTION SYSTEM • North 1 ftAo1cFE • a • 1 North 3 -90 Deg Els 6" SR 45 Deg El with 6" Reducer (Tank 11 [rank 31 10 LRY 10" x 8" x 8 " Y 7 8' SR 90 Deg El W 8" Take off Ilank 21 Tie -in From insid e of plant 16° 4' thick concrete slab with 6 x 6' reinforcing wire 18" Bag House & Fan Detail Note: Size 22 NY Blower, 15 HP with 3' of static pressure. 10,000 CFM, 9.06 HP pull load. A-A Scale 1/4' : 1' Torrit Model 130 See fan curves 1/2' x 4" concrete anchors • 10 To Mezanine 14" x 12" x 10" Y :xisting --sigh Speed Dispenser 1.500 CFM 10 HP 11.500 CFM RO HP 11.500 CFM 15 HP r0 00 CFM HP 11. 500 CFM 0 HP Slide Sate Slide 5ate Slide 5 6' Slide Gate 6' Flex hose � to tank Typical Disperser Exhaust 6' 45 Deg EL 6 "— Slide 6 " 5ate Slide 6 " mate 6 " Torrit Model 130 To Silicon feactor 2000 CFM 12" 6' Duct from main x 12" x 6" Y -- 12" x 10" x 6" Y 10" x 10" x 6" Y 7 10" x 8" x 6" Y 10" x 6" x 6" Y Parcel Number 3523049014 Legal Descriptions 352304 14 POR OF GL 6 IN SW 1/4 OF SEC DAF BEG AT PT S 89 -01 -50 E 505.54 FT & N 00 -58 -10 E 313.17 FT FR SW COR OF GL 6 TO TPOB TH S 23 -27 -22 W TO S LN GL 6 TH S 89 -01 -50 E ALG SD S LN TO BANK OF GREEN RIVER TH NLY ALG SD RIVER BANK TAP S 67 -36 -00 E FR TPOB TH N 67 -36 -00 W TO TPOB New concrete pad REPLACEMENT OF EXISTING DUST C ❑LLECTI ❑N SYSTEM PLAN VIEW Scale 1/4' 1' Notes Existing Makeup air at 6500 CFM heated ounted on roof 6' 45 D EL d 1 c5 i L W d CL 0 L co W °' o0 ) CO CU 0\ u S 0 +, 0 : Q o oN CO ifEWED FO CE 1 E COMPLIAN APPROVED MAY -1 2001 :ity of Tukwila i WIN O IOy -' ) DATE: 4/24/2007 REVISION: New SECEIVED APR 2 f; 2rO1 . 2 A • 1 North 3 -90 Deg Els 6" SR 45 Deg El with 6" Reducer (Tank 11 [rank 31 10 LRY 10" x 8" x 8 " Y 7 8' SR 90 Deg El W 8" Take off Ilank 21 Tie -in From insid e of plant 16° 4' thick concrete slab with 6 x 6' reinforcing wire 18" Bag House & Fan Detail Note: Size 22 NY Blower, 15 HP with 3' of static pressure. 10,000 CFM, 9.06 HP pull load. A-A Scale 1/4' : 1' Torrit Model 130 See fan curves 1/2' x 4" concrete anchors • 10 To Mezanine 14" x 12" x 10" Y :xisting --sigh Speed Dispenser 1.500 CFM 10 HP 11.500 CFM RO HP 11.500 CFM 15 HP r0 00 CFM HP 11. 500 CFM 0 HP Slide Sate Slide 5ate Slide 5 6' Slide Gate 6' Flex hose � to tank Typical Disperser Exhaust 6' 45 Deg EL 6 "— Slide 6 " 5ate Slide 6 " mate 6 " Torrit Model 130 To Silicon feactor 2000 CFM 12" 6' Duct from main x 12" x 6" Y -- 12" x 10" x 6" Y 10" x 10" x 6" Y 7 10" x 8" x 6" Y 10" x 6" x 6" Y Parcel Number 3523049014 Legal Descriptions 352304 14 POR OF GL 6 IN SW 1/4 OF SEC DAF BEG AT PT S 89 -01 -50 E 505.54 FT & N 00 -58 -10 E 313.17 FT FR SW COR OF GL 6 TO TPOB TH S 23 -27 -22 W TO S LN GL 6 TH S 89 -01 -50 E ALG SD S LN TO BANK OF GREEN RIVER TH NLY ALG SD RIVER BANK TAP S 67 -36 -00 E FR TPOB TH N 67 -36 -00 W TO TPOB New concrete pad REPLACEMENT OF EXISTING DUST C ❑LLECTI ❑N SYSTEM PLAN VIEW Scale 1/4' 1' Notes Existing Makeup air at 6500 CFM heated ounted on roof 6' 45 D EL