Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-107 - NORDSTROM RACK
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M07 -107 Nordstrom Rack 17200 Southcenter Parkway RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit 13 Personal Information — expiration dates, or bank or other financial RCW DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. Parcel No.: 2623049117 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 17200 SOUTHCENTER PE TUKW Contact Person: Name: CHRISTINE JOHNSON Address: PO BOX 249 , AUBURN WA Contractor: Name: AUBURN MECHANICAL INC Address: PO BOX 249 , AUBURN, WA Contractor License No: AUBURMI163BA DESCRIPTION OF WORK: INSTALL (6) NEW AIR CONDITIONING UNITS Value of Mechanical: $50,000.00 Type of Fire Protection: NORDSTROM RACK 17200 SOUTHCENTER PY , TUKWILA WA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 City►f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 O 0 6 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 838 -9780 Phone: (253)838 -9780 Expiration Date: 09/12/2008 M07 -107 06/06/2007 12/03/2007 Fees Collected: $730.58 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -107 Printed: 06-06 -2007 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us xa� wi Permit Number: M07 -107 Issue Date: 06/06/2007 Permit Expires On: 12/03/2007 Date: Ili `di Lod r ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the ormance of work. I am orized to sign and obtain this mechanical permit. / Signature: /'.- � _ Date: /4 467 Print Name: eiC /3 S> A This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -107 Printed: 06-06 -2007 Parcel No.: Address: Suite No: Tenant: NORDSTROM RACK City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17200 SOUTHCENTER PY TUKW PERMIT CONDITIONS Permit Number: M07 -107 Status: ISSUED Applied Date: 05/10/2007 Issue Date: 06/06/2007 1: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 2: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 3: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. T: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDMONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) doc: Cond -10/06 M07 -107 Printed: 06-06 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -107 Printed: 06-06 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:• / /www.ci.tukwila.wa.us AeS ( ir;; /)%rie Date: 6'f 6_ ia7 M07 - 107 Printed: 06-06 -2007 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. Jj1 01-- , N- Plumbing/Gas Permit No. P&D �. 1 Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Z(o23049 0 8n Site Address: I Sp∎Yih rTt .✓ Y kiuua Tenant Name: t'O1 'RaGlc Property Owners Name: Ll..) 1(7 W € LLL Mailing Address: 1 SO C.t.I -.Y 'Pa rkwa.t IIU •j CI WA 9$1 State Zip Suite Number: /10 City New Tenant: Floor: ❑ Yes CONTACT PERSON Name: 0.416'2-tins✓ JtAriA5Dyi Day Telephone: 2 - 5 3 . $3$ -97 ' Mailing Address: f .0 . BOX 2 .4"1 (..i v n °t ?07 1 City State Zip E -Mail Address:C 1Vibhv' 4 2U IOU ✓Y) V)U.2I. C.oyvl Fax Number: 2�3. 233• /3 �- GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: Aubur r f'YI - .-h' n ► G2 I , i Mailing Address: P 0. Dby. 2.4 ci Contact Person: C,yl Y it1'► we./ Jot') n h E -Mail Address: C.hYt61"11rl t...(4? aaubu v rlri i.a 1 . ow) Contractor Registration Number: -ieN8U12.3%.1 4 1D3 6 A Company Name: Mailing Address: Q: \Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh 7Ilcblt.r n City WR 9VU7 State Zip Day Telephone: 253. 73 3$ -91 'n Fax Number: ZS3• $3 3 • 1 3 g 4 Expiration Date: ❑..No ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >I00K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refr'g/Cooling System (f nits // l0 Incinerator - Domestic Emergency Generator Air Han ing Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: f WOUY n (Y1..c.rtra n 1La � Inc.. Mailing Address:: P 0 . f5bx 24' Contact Person: I r( '1 Y1 L Jbk nsb r3 E -Mail Address: C..V11f ifyh Yl ti a i ht I v rl YYl �i t ( - Contractor Registration Number: AUE,U 12.1v1'Z i 10313A Valuation of Project (contractor's bid price): $ 2 2, ax.) Scope of Work (please provide detailed information): Y co f `c(_A) 2■Y C.bfld 9 Un cis Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ....12" Fuel Type: Electric ❑ Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q: W pplicanons\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh tl ubur n //Vfi 92b'1 l City State Zip Day Telephone: 2.53. fArn Fax Number: 2.53. 833. 13R �} Expiration Date: 9/ 121 0g Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) 2a Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste fl 0 a ✓ DY ai t n 2.. Clothes washer, domestic I Floor drain Sinks Z REft UC,t d cVLSsurellincb 2. Dental unit, cuspidor Shower, single head trap Urinals I if C. TV vvt p I Dishwasher, domestic, with independent drain Lavatory 1 Water Closet s E 6 t3-1t b n I Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent ) M0? St i I< I Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific Ras Additional medical gas inlets/outlets — six or more PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: TT Wove V✓ tr1 V Y) t c h 2 v t c a I l ✓) c Mailing Address: P. o . 'BM 2-.41 Zip 253. RSR•91et, � .�'l v l5'11 aV}�l i'►9 '�r_I•I ✓� t ( (,614/ Fax Number: 2.S3• 83.3•132 Expiration Date: ° I 12./ 6 9 Contact Person: Ui.►r n t, n s D Y) E -Mail Address: 2 Contractor Registration Number: RUFSU 12.M•t1 Valuation of Project (contractor's bid price): $ SO, cocD Scope of Work (please provide detailed information):_ TUr n i51r) 4 Install n sW Nu') (€- roo S , n4,k_a.) mairri r, roor, theta f t t j d al- rati.,7 as s1iewrt ?Irevidt4 dxaw•tn5s . Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:\Applications\Forms- Applications On LineU -2006 - Permit Application.doc Revised: 4 -2006 bh p\pi l 8o-1 City State Day Telephone: TI X +l,ty� $ -For- Page Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R OR AUTHORIZED Signature: 94.4_4470A Date: s/ $/ a7 Print Name: ejnVLStt J ahh -tor) Mailing Address: 1 V - 00X 2`4'1 Date Application Accepted: Q: \ApplicationsWorms- Applications On Line \3-2006 - Permit Application.doc Revised 4 -2006 bh Date Application Expires: Day Telephone: 23 ' ZZ g • ° l 1 a i kA191 IY YI wn 91 1 City State Zip Il(la10' Staff Initials: Page 6 of 6 ACTIVITY NUMBER: M07 -107 DATE: 05 -10 -07 PROJECT NAME: NORDSTROM RACK SITE ADDRESS: 17200 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 6‘toi B g"Division Public Works ❑ Comments: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: Notation: Documents/routing slip.doc 2-28-02 PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions REVIEWER'S INITIALS: PERMIT COORD COPY Fire Prevention Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1 Incomplete ❑ DUE DATE: 05-15-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 06-12 -07 Not Approved (attach comments) ❑ DATE: Planning Division Permit Coordinator Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: July 3, 2007 Christine Johnson Auburn Mechanical PO Box 249 Auburn, WA 98071 RE: Refund Nordstrom Rack —17200 Southcenter Py -(M07 -107) Dear Ms. Johnson: Enclosed please find a check in the amount of $472.37, equal to 80% of the permit fee paid for the above referenced project. Per City Ordinance, 80% is maximum allowed for this refund. The scope of work outlined in the permit was performed by another contractor under a separate permit. If you should have any questions, please contact our office at (206)431 -3672. Sincerely, 1 Brenda Holt Permit Coordinator end City of Tukwila Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director xc: Permit No. M07 -107 H:\Dacuments\Bond Release\M07 -107 - Refund Letter.DOC bh 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 CITY OF TUKWILA, WA 98188 -2544 � ^ INVOICE NUMBER „ .DATE : 06/27/2007 P:0. NUMBER".; 80% FEE - M07 -107 070207310 THE FACE OF THIS DOCUMENT HAS A COLORED BACKGROUND -NOT A WHITE BACKGROUND PAY TO THE ORDER OF CITY OF TUKWILA 6200 Southcenter Boulevard Tukwila WA 98188 -2544 ACCOUNTS PAYABLE CHECK PLEASE DETACH BEFORE DEPOSITING PAYABLE111ROUGH BANK 1514154*w%Park East Tukwila, WA gales Four Hundred Seventy Two Dollars and Thirty Seven Cents AUBURN MECHANICAL PO BOX 249 AUBURN, WA 98071 w1V•i'V.,f NO. 472.37 THE BACK OF THIS DOCUMENT HAS AN ARTIFICIAL WATERMARK -HOLD AT AN ANGLE TO VIEW Memo Jule 19, 2007 To: Laurie Anderson From: Brenda Holt Re: M07 -107 Please refund the following fees to Aubum Mechanical. The scope of work under this permit has changed, therefore a new permit is being issued. 80% of Permit Fee $472.37 Total $472.37 Please make the check out to them and I will forward it to them: Aubum Mechanical PO Box 249 Aubum, WA 98071 Xc: File No. M07 -107 H:1DocumentslLetters1M07 -107 - refund memo.doc bh City of Tukwila Permit Center Receipt No.: R07 -01043 Initials: JEM User ID: 1165 Payee: AUBURN MECHANICAL ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: M07 -107 Address: 17200 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 05/10/2007 Applicant: NORDSTROM RACK Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 0009249 590.46 Account Code Current Pmts 000/322.100 590.46 Total: $590.46 Payment Amount: $590.46 Payment Date: 06/06/2007 10:49 AM Balance: $0.00 9107 06/06 9716 TOTAL 590.46 c1nr:• Rac int -OR Printarl• OS-OS-9007 Auburn echanical P.O. Box 249 Auburn, WA 98071 Attn: Bob Benedicto City of Tukwila 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Bob, I am writing you to request a refund on a mechanical permit that I applied for in June 2007. The permit number is M07 -107 for Nordstrom Rack located at 17200 Southcenter Parkway, Tukwila, WA. I was under the impression that we would be installing the 6 AC units but it turns out that Auburn Mechanical is only responsible for the gas piping of the units and that PSF Mechanical is in charge of the installation and has already received their mechanical permit for the 6 AC Units. I have reapplied for the gas piping and will be paying for those fees. Normally I wouldn't request a refund but the mechanical permit fees totaled up to $730.58. Thank You for Your Time, Tel: (253) 838 -9780 Fax: (253) 833 -1384 AU- BU- RM- 1163BA Christine Johnson Auburn Mechanical, Inc. Christine @auburnmechanical.com 253- 838 -9780 a ea, 4 tA, trk —7 6/6/2.:0 RECEIVED 'gyp 18 2001 GOMM DEMEO June 14, 2007 YeM.- 112.31 Dora RECSETS -O6 RECEIPT NO: R07 -00803 Initials: JEM User ID: 1165 Payee: AUBURN MECHANICAL SET ID: S000000760 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount M07 -107 TOTAL: ACCOUNT ITEM LIST: Description Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLAN CHECK - NONRES 140.12 140.12 TRANSACTION LIST: Type Method Description SET RECEIPT Payment Date: 05/10/2007 Total Payment: 140.12 Amount Payment Check 0009201 140.12 TOTAL: 140.12 Account Code Current Pmts 000/345.830 TOTAL: 140.12 140.12 8071 05/10 9710 TOTAL 140.12 AIR CONDITIONING UNIT SCHEDULE e _ I 1403 PARK MFR/MODEL UNIT LOCATION AREA SERVED NOM. TONS. TOTAL (MBH) SENSIBLE (MIEN) LATENT ( ) EVAP. FAN MN OSA CFM POWER D.S. INCLUDED AMPS HEATING • YIN EF - EIlCS WS FUNCTION REMARKS FLOOR GRID CFM TSP ESP HP RPM IN (MBH) OUT (MBH) TEMP CONTROL AG-1 WANE YGD -500 ROOF FG sae5 FLOOR - SOUTHWEST 25 242 W 52 90O0 - 1.41 7.5 447 2t0,0 4GOV/3$ YES 56 MA 250 2O3 2441 c17 EEIR • • 0 0 © ©0 0 0 AG-2 TRAT E WO -300 ROOF DG SALES FLOOR - SOUTHEAST 25 20 20 52 4,000 - L41 75 447 2.050 440V/30 YES 56 MCA 00 203 24 47 ®R • • 0 0 0 ©0 0 0 AG-3 WANE ¥W11-300 ROOF F4 SALES FLOOR - NORTHREST 25 202 21O 52 4000 - L41 7.5 447 2.050 440V/30 YES 58 MA 250 203 249 47 ®t • • 0 0 © ©0 0 0 AG-4 WANE YGO -300 ROOF 04 5ALE5 FLOOR - NORTHEAST 25 K2 21 51 4.100 - L44 7.5 ` 954 Ipso 440V/3$ YES 56 MA 230 203 2491 47 EEC • • 0 0 00 0 0 0 AG-5 S TTATE YCD-O ROOF Cl TAILOR/ OFfxE/ MAIL/ OiRPJAErOOMV 1.P/ MAN 125 143 126 17 353 - 1.30 3 424 430 4001/3$ YES 33 MCA 150 122 1617 91. Eat • • 0 0 0 0 ©0 0 0 AC-f. TRINE YCO-FO ROOF 64 TOCK/ REG5VNN6 •25 05 TOG 24 4.00 - 120 3 624 00 440V/3$ YES 33 MA 130 122 1637 4.4 EER • • 00 00 00 0 FAN SCHEDULE MARK MFRIMODEL UNIT LOCATION AREA SERVED CFM SP HP RPM POWER M[CLUDED D.S. MCAT. EMCS FUNCTION _maw REMARKS FLOOR ARID SUS _ CO NTROL EF-1 COOK 80 AGED 15T 04 MAINTENANCE DRYER 400 050 1/4 1.4D 12OV/1$ N0 63 • M 0 0 0 EF-2 COOK K5 AGED 15T G5 DREAK ROOM/RCSTROOMS AOO 033 V2 1.021 120V/1$ NO 147 • ,r$ 0 © 0 EF-3 GOOK 100 AGED 15T C4 TALOR 600 0.50 I/ 1,751 1ZOV/1$ NO 80 • 1416 000 TF-I WOK 24XMP IT G4 EQI'MElT ROOM 2200 0.20 1/4 770 110V/1$ NO 243 • • 0 0 O FIT-105 TRAHE 1/5GF 140350 LP GMERA 13 1350 K5 V2 VAR 277V/1$ - - NO 14'+$ AG-5 RE -I COOK 46 H(D( I5T E4 SALES - NORTH 14,000 050 3 50 400//3$ NO 1301 • 0000 REF-Z GOOK 48 HXDA 15T EG SALES - SOUTH 14.000 0.50 3 562 44OV /3$ NO 1301 • 0000 DIFFUSER SCHEDULE MARK MFRJMODEL DESCRIPTION FAN CFM PRIMARY CFM FAN HEATER D.S. INCLUDED INLET SIZE A/C SYS. REMARKS MAX FM HP SPEED POWER KW POWER 11T -101 WANE VSGF 140550 WOMEN'S DRESSING ROOM WOO WOO 165 J TITUS/PAR PERFORATED LAY-IN RETURN OR EXHAUST GRILLE WITH DUCT COLLAR - - NO M TITU5 /300R5 SURFACE MOUNTED DOUDLE PEFLEGT1ON SUPPLY RC613TER N TNTU9 /230. SUMO MOUNTED RETURN OR EXHAUST MLLE 0 TITU5/50F SURFACE MOUNTED E66GRATE RETURN OR EXHAUST MLLE 1/3 VAR 277V/1$ T TTTVS /2JRL %WAGE MOUNTED RETURN OR EXHNJST RE615TER (STEEL) WITH ODD ,r$ lit .• •._-. •. . :. . :1 .- .. FIT- -103 TRAINS VSGF 140450 DREAKROOM V TRUS /TAG LAY-IN DIFFUSER ERA& 33 • 2F/41',34 • 16'216% jP • 15'KTS' AND SMALLER W TRUS/TDC SURFACE UOt*IT Off1J5&R (FRAME TYPE 8 WITH ODD - - NO 1416 AG-5 O FAN INDUCTION TERMINAL UNIT S CHEDULE MARK MFRJMODEL AREA SERVED FAN CFM PRIMARY CFM FAN HEATER D.S. INCLUDED INLET SIZE A/C SYS. REMARKS MAX FM HP SPEED POWER KW POWER 11T -101 WANE VSGF 140550 WOMEN'S DRESSING ROOM WOO WOO 165 1/2 VAR 277V/I0 - - NO W$ AG-4 O RT - 102 TRANS V56F 120350 HENS DRESSING ROOM GOO 100 105 1/3 VAR 277V/1$ - - NO ,r$ AG-5 O . FIT- -103 TRAINS VSGF 140450 DREAKROOM 1000 1000 GOO V3 VAR 277V/1$ - - NO 1416 AG-5 O TIT -104 TRAM VSGF KOGSQ MANAGER/WORKROOM/PR 1735 1935 G10 V2 VAR 277V/1$ - - NO 16'16 AG-5 O FIT-105 TRAHE 1/5GF 140350 LP GMERA 13 1350 K5 V2 VAR 277V/1$ - - NO 14'+$ AG-5 OI • MISCELLANEOUS EQUIPMENT SCHEDULE MARK ITEM AREA SERVED D.& INCLUDED EMS FUNCTION DESCRIPTION 24' 20' x x I.:4:: r 2' TEMP CONTROL «u -1 6A5 CHIT HEATER Moo(9..QVF -IO0 REGEVNG NO - - W0 WV NPIR. eoS EP. ELEGTRONf. SPARK IGtiu0N. V3 HP, 45 AMP,16 VOLT FAN MOTOR, FURNISH REMOTE THERMOSTAT APV TIRE GUARD TPE RM105TAT DOVER OF-1 TRANS DYPASS IMZEAKROOLV TAI / - - - 20'$ DYPAScs MIMIC TAG-5/ LT-1 LINT TRAP UANTB(ANGE DRYER - - - P5F IEGHNW4GAL LINT TRAP I E"-VIEWED f v I 1 MI* COMPUANC FILTER SCHEDULE MARK QTY SIZE DESCRIPTION AG-I 4 4 24' 20' x x I.:4:: r 2' MORGAN AR FR-TER PERFECT PLEAT HA AG-2 4 4 24• it 24' a V 20`x25'12' AMARIGAN AR FILTER PERFECT PLEAT IN AG-3 4 4 24' z 24' It r 20'x2512' MEAGAN AR FILTER PERFECT PLEAT HA AGE 4 4 24' x 25' a r 20'x2512' AMERICAN AR FILTER PIRNEGT PLEAT HA AG-5 4 2 20" x 20' r 20'125 x r MEAGAN AR FLT& PERFECT PLEAT HA AG-6 4 2 2°.20.1,22.5.°.: r r AMERICAN AR FILTER PERFECT PLEAT HA W -20' CHEW O' - V2• X ITT DOX • 101.102 TEA K 120 - , r MEAGAN AR FILTER NOUSTRAf- ram FLIER 103.104 • 105 X PRESSURE DUCTWORK UPSTREAM Or PRESSURE REOIX.TION YE5 4.2 14 1x09! O" -6• VAV SCHEDULE MARK MFRJMODEL AREA SERVED CFM C. CFM !SIZE SIZE YS SYS. REMARKS VAV -101 TRAM VGGF 12 TALOR G50 13O RV AG-5 O X Pdi 1.. 9 . 4.2 rc,: -.lm.Q.. • cn . (NEW o• X ALI- E)04*P T AND RETURN OUGTVORK YES 42 W -20' CHEW O' - V2• X DRAWING SCHEDULE 1 DWG. DESCRIPTION A4PUCA TION TA-001 HVAC 5QEOU.E5 NO GENERAL NOTES X X M-101 FIRST ROOK HVAC PLAN 11d02 ROOF HVAC PLATS 11-201 14VAG SEGTION5, PETALS AND SEnefax OF CIERATION5 CRY YC Cc E X Pdi 1.. 9 . 4.2 rc,: -.lm.Q.. • cn . FLEariE D(1CiN10RK APPUCA110NCIWtT 1 PRESSURE RANG 11ERMAF1B ME A4PUCA TION 0 p ; '' R VALUE 4.2 4.2 X X SWF a'05.) O' -10' LOW PRESSURE DUCTWORK DOWNSTREAM OF PRESSURE REDUCTION (POW 10•-G• LOW PRESSURE 01/fiTWOR1C DOWNSTREAM OF PRESSURE REDUCTION 18'-20 (POS3 O' -4' X LOW PRESSURE OUGTWORK DOWNSTREAM OF PRESSURE RECUGTION YE S 4.2 4 (NEW o• X ALI- E)04*P T AND RETURN OUGTVORK YES 42 W -20' CHEW O' - V2• X AU. EXGIMJST AND RETURN OUGTWORK YE5 4.2 4• -12• (P05) O -10' X PRESSURE DUCTWORK UPSTREAM Or PRESSURE REOIX.TION YE5 4.2 14 1x09! O" -6• X MEDIUM PRESSURE 01/GTWORK UPSTREAM OF PRESSURE REOUGTWON yES 42 16 -20' a'QSS O' -4• x MEDIUM PRESSURE DUCTWORK UPSTREAM or PRESSURE REDUCTION YES 4.2 r G E 3 E SYMBOLS & ABBREVIATIONS 9YLOOL ADDREV. A.G. A D. AF.F. DOD. D.S. D.O.G. D.00. E. di " 4 f OHO w 250 0 REGT.'\ rROMP ER- 0 0 / ®t i8! GUN CIA. O.S. O DN. EAR 10.6. EF.G. E.IJJL EC_ EXIST. EA F.F. EXT. FJT. FD F.S.P. F.O.D. F.O.T. F.G. 6.G. H.P. MWA MLUF. M.G. ODD. OA POO RA RAIL 2•_ DESCRPTIOS AR GONDlTIDN1I16 UNIT AR DOOR 'EVE FINISGEO FLOOR DACKCRAFT DAMPER DR• SCREEN DOTTOM OP MLLE DOTTOM OF DUCT CENTER LINE GADINIET UNIT HEATER DIAMETER DISCONNECT SWITCH DRAWING NOTE DUCT DROP N DIRECTION OF ARROW DUCT RISE N DIRECTION OF ARROW DOWN ELECTEG Gf9•N6 HEATER ELECTRIC DUGT GOL EL.EGTRIG FAN GOL ELEGTRIG UN1T HEATER ELECTRICAL CONTRACTOR ELEVATION EXISTING EXHAUST Art EXHAUST FAN EXTERIOR OR EXTERNAL FAN elDU T10N TERMINAI. FIRE PAMPER FRE /SMOKE DAMPER FLAT ON DOTTOM FLAT ON TOP R•PJ(IDL•E CONNECTION &NEM- GONTRAGTOR GRLIAL RE615TETR, OR DIFFUSER TYPE NEGK "RE INCHES) AR QUANTITY OGFU 6/0D WW1/DER HEAT PUMP OR H OR5WOV1 R MAKEUP AR MAKE-UP AR FAN MEGHANGAL CONTRACTOR MOTORIZED DAMPER MIEGRANCAL EQUPMBNT TAG OPPOSE) DLADE DAMPER OUT5DE AR PONT OF GONNEGTION REDALANGE DOSTN6 RH.OGATE RETURN AR RETURN AR MLLE RETURN/EXHAUST DUCT DOWN T DUGT W 'DE INLET GAN 5D. 5uO:E DETECTOR S. DI PR- SMOKE DAMPER 'S S.C- SCUD STATE SPEEO CONTROL SJ.. SOUND LINING SQUARE TO ROUND DUCT TRANSITION 5/5 START /STOP STATIC PRESSURE SENSOR 5A SUPPLY AR SUPPLY DUCT DOWN SUPPLY DUCT UP 5W_ SWITCH TG TEP&ATURE CONTROL TS_ TORTRATLIRE 5EN50R T'STAT. THERMOSTAT T.O.D. TP. T.V. TOP INLET LAY-ti TOP OF DUCT TRANSFER FAN TUR1RI6 VANE-5 +' - •mss: _ are-Se-ars es E. ,. rae 3 i« Yr. :, asx :•:r = -e•Yt tee es. ..ill :tr V.A.V. VARIADLE AR VOLUME TERMINAL VD VOLUME PAMPER IRE GUARD COVER OVER TEMPERATURE SENSOR • WEE WARP DOVER OVER THERMOSTAT 4. 4 5. _. GENERAL NOTES L ALL DUCTWORK SHALL DE 1115TA21.0 N A WORKMAN LIKE MANNER N AGGORDANCE WITH ALL APPLIGADLE GODES AND ORONANCE5:000E5.RULES AND RE6U.ATMONS OF THE STATE OP WASHINGTON. THE CITY Of TUCWLA. THE 2003 INTERNATIONAL MECHANGAL CooE.AND THE 2004 WASINGTON STATE ENERGY CODE 2. REGTAN6U.AR AND ROUND OUGTVORK SHALL ERE GALVANIZED SHEET METAL WITH 501INH.Nd6 OR EXTERNAL INSULATION WRAP AS IVIGATI• N NOTE 4 UNLESS OTHERWISE NOTED. 3. FLEXDLE DUCTWORK SHAL(. DE GLASS 1 CONFORMING TO W.. STANDARD 161 AND APPLIED A.GOROIN6 TO TADLE DELOW WITH IAA 1CMI LENGTH AS REOUNCEO DY LOCAL WOE OR A6REEMENT. ALL DUCTS SHOWN LID ILL. OE F THICK UNLESS OTHERWISE NOTED.IR VALUE PER ENERGY 000f3 TAPE OR SEAL ALL JOINTS N CONGEALED DUCTWORK SYSTEM ALL. CUTTING. PATGHN6, FRAMING, FRE SAFi l6. PANTING. ROOF OPDII46 C RD% ROOFING EEG., REHIRED TO INSTALL I GHANCAL SYSTEM HELEN SHALT. DE DY GENERAL GONTRAGTOR, I CA4101146 ALL FLASHING. SEALING, FRAMN6 AND ROOFING ON SHEET METAL DUCT ENCLOSURES. 7. M ECHANGAL EQUPM ENT AGGESS FARMS el FURRED ENCLOSURES SHALL D!: FURNISHED AND INSTALLED DY 6Ei+NtA1. CONTRACTOR. 6- POWER V1046 AND GONtEGTfON5 TO HVAG earmuff SHALL DE DY ELECTRICAL GONTRAGTOR. CONTROL WIRING AND LOW VOLTAGE GONEGTION TO HVAG EQUIPMENT SHALL DE DY ELECTRICAL CONTRACTOR. 4 ALL EXPOSED ROUND DUCTWORK SHALL. DE SPIRAL SHEET METAL. 10. ALL MEOW PRESSURE DUGT TO DE MANUFAGTUREP N ACCORDANCE WITH SMAGNA MEDIUM PRESSURE STANDAR05. IL DUTT& ALL JOINTS AT 50UlDLI LNG N MEDUM PRESSURE DUCTWORK. 12. ALL MEOW PRESSURE DUCT TAKEOFF FITTINGS SHALL DE DOOT TEES UNLESS OTHERWISE NOTED. C. INLET GOMEGI1ON5 TO ALL MEDIUM PRESSURE TERMINAL UNITS 5144.U. HAVE DEAD AND MOW TO ASSURE POSITIVE R.EXDLE DUCT GoI GT(ON. /ANNUM FLEX DUGT LENGTH SHALL DE THREE FEET UNLESS RE5TRIGTEO DY LOCAL GORE OR AGREEMENT. 14. ELEVATIONS SHOWN ON THESE ORAWI465 ARE INTENDED FOR DESIGN GOORONATfON ON.Y.RNFER TO HVAG 5(10P DRAWN65 FOR EXACT ELEVATIONS AND DRENSIONS. 6 EXTERNAL OUGT WRAP TO DE PROVIDED AND INSTALLED VI AGGORDANGE WITH LOCAL STATE GOOF' IG• TM HEW HVAG SYSTEMS SHALL COMPLY VITH 2004 WASHINGTON ENERGY CODE SEGTION 14K. SCOPE OF WORK THE PROJECT TILL DE GOMPESED OF A NEW CONSTRUCTION FETAL SALES FLOOR.ORE3SN6 ROOMS, OFFICES. RE5WOOM5, STOCK, AND RECEIVING AREA' TH)5 TILL NECESSITATE THE ADDITION OF ROOFTOP A/G EQIIPMEMT,ROOFTOP FAN UNITS. FAN TERMINAL. LINTS, DUGTVORK, 0IFFUSERS, AND TEMPERATURE 5Dr50R5 ALONG WITH THE AOCMON OF MISCELLANEOUS MINOR HVAG AGGESSORE5 O MOTOR STARTER TO DE MOWED DY OTHEtci_ ® PROVIDED WITH FACTORY DAGH9RAFT DAMPER. ® PROVOS WITH DROSCREEN. O FRONDS WITH FACTORY INSTALLED EXTENDED GREASE LNU:9,14146® ACCE55 0004/5, L.AGEADL•E FLTHt NOOOR AR QUALITY GRAN PAN,IOV LEAK DAMPERS. TRACER GOY. 4TERFACE AND GRA.VCGASE HEATER". O SMOKE DETECTOR N REIM. DUCTWORK CROWDED DY OTI.'s.1145TALI.® A.+D WEED DY ELECTRICAL. CONTRACTORI 3O LOCATE STATIC PRESSURE PRODS AS 1 5H41•I ON PLAN SHIRT' 4O FACTORY APP.® CLACK EPDXY COATING ON CONDENSER COL' s • 9 __ -- 9 -- O MOVE & WITH 540 DISCHARCEIRE5SURE INDEPENDENT CDG CONTROLS, TEMPERATURE 5130OR D AMAG TE -205) WITHIOUT 1.060.277V TO 24 VAG TRANSFORLIER.U.L.LI5TED DISGONNEGT SUTTON. 1 • ® STANDARD DISGOINtEGT DY OTHERS. 0 PROVIDE WITH TRINE VARIADLE FREQUE NGY DRIVE ,FIELD /INSTALLED. MOWED DY MECHANICAL CONTRACTOR. NSTALLE6 AND WED DY ELECTRICAL GONTRAGTOR' O ROOF QJRD AND LEVELING DAM 15 FURNISHED 4 N5TA1•L • DY LANDLORD DEVELOPER. O some Li* Poser CONICTT NN. 0 reowE WITH FACTORY INSTALLED DOV)FLOV ECONO1iZEr- ® FACTORY *WALED 6FI5&Vf OUTLET s40NFPOSe®L QOV - SERVILE PROVIDED DY B.EGTRDGAL CMITRACTO[ SEPARATE MOAT ra MED G Me al ��. Gtsc4 C`, c: a . %x3 Blefggal . ._:(;;:.: z : t"..:v.: r ./ -:::3m- ar_:: ;.: :� _ . . -e.e.e '1 rorae s • 1 0 O PROVIDE WITH 540 DI5CHARCEPRESSURE IN NIROLS, DEPENDENT ODG GO To/rename 58450C IMAMAG TE-205) WITHOUT 1.060.277V TO 24 VAC TRANSFOREER. W_U5TED DOCON 4 CT SWITCH. I: N. POI re4of among it attgodt Of Enos a o _can Me _ Citycf Tfanfi eumovn sOdVl5ifS1 It M.01-101 APPROVE - s � 1 N>cti wzroo J6d. • • O 1==3 vt) O z 0 Z NI-001 O 0 0 1 ISSUED/REVISED DATE BID/PERINT SET MI101 HVAC SCHEDULES AND GENERAL NOTES 0 JOB NUMBER 200437.00 • • w • • • • • • M al 11� ; O *0 cn C, 0 m m 1 I' I / J l i l r'I • • • . l � . 1/ - 1 1 N • . 1 1 - • • ..••rW- O. 'o —• • • _ . • .• . . . • .. • en 1 1�i ! I ' v.t1. i4,.t s : R •►•+ 1 ; 1 1 1 1! I 11 1! 1 _ I H 1! I tr. '.•L'.'.... t 4. CAL LISON M 4 CALLISON ARCHITECTURE, INC. 1420 Fifth Avenue 02400 Seattle, Washington 98101-2343 T 208 823 4846 R 208 823 4825 www•osIllson.com !^ 1 ....I._ ...... • •__ • •• I... .•._ ._. _....••.._• MMI • \ � 5 i 1 .- i i_ ... 4. ....... ;; ..4...1._..i i ._, 1 _4...,._., , ,1_!:1;, ; 7.177.i .!—.± ; ' 1 ; 7: I- . 1 :1:"_i7_. : ; i 1 ......1 I 1 : r .1 , Zt ft 4' 1 ; e 1 1 tg mniossms tt • • • PSF MECHANICAL, INC. 9322 14th Avenue South Seattle, WA 98108 T 208 764 9663 F 206 702 8381 www.psfmech.com • • MUNI • WIN= Mat 10.0:L eromm._.© ;_. I L., OWNER NORDSTROM, INC. 1700 7th Avenue, Suite 1000 Seattle, WA 98101 T 206 303 4300 P 206 303 4319 • w J • • x 1 4 a •41. •MMf••.MMyyMANI,NI,.I 1 t: ni4 M .MII 41w0 If 11 0 0 -0 n Z 1; 11 , 1i : 1 1! 1 1, - . 3 O � I e II NA x 0 g N ! I 1 1 I i ; 1 ,1' I II 1 i � : I ti m X 1, 1 I, 1 •11 1, 1 ' 1, 1 I, 1 1 1. • • ! 1 •• I 1' !I • • I • • I 1 1 • • I' I 1 • 1 • 1 1 1 ,I 1 . 1 1 • • 1 1 • 1 1'1 • _,_ ;1 1 1 1 I I' d n r I0 P 0 • 1 e .': r�r 1' 1 n. I• ;r I. • . • • r CALLISON • .»._ ._._._._ ._._._._._._._. — r1•_ ._. r•_• •_•_._• wow •_ mil • .• ._ •_•_•_•4.. ._ • _•_._._•_._ _•_._ •w._._ •_. _._ . . I I _•_•_._• No. - _ •_•r•_•_•_._•_•_ •_•_ Ili•_._._•_•_• _•_•_•_•_•_._._•_•_._ . 1 1 1 i I j - ._.. - • 4 •... _.. r 1 1� ... • 4__ . ! 1. —_ 1 1.. _. _. • •_ ! CALLISON ARCHITECTURE, INC. 1420 Fifth Avenue #2400 Seattle, Washington 98101 -2343 T 208 823 4648 F 206 623 4828 www,calllson.aom r r• n I ; i 1 i 1 ! 1 1 i I . 1 i 1. ► 1 �''• 1 I . 1 1 , ri• + f • • 1 � . y 1 II - P erg \ ZII # j • 1 • 7' I 4 - I ' 1 ( .^1• os,A. .4- 0.0A. il' • 1 , OWNER: POP MECHANICAL, INC. 9322 14th Avenue South Seattle, WA 98108 T 208 764 9663 F 206 782 8381 www.pefmoch.com • - 11 44 • 1' 11 _._._.._._. _._._._._._._._._._._._._._._ ooPON. ;1 !;- !I: 4' ,1 • 4 aa 2 I 1 ! ■�f�1ii� 1 J I i l $ ! I` �J I. ! 1 1 4 I I!. .1 i , I! ' 1 1 1 0 1 I t 1 l i • I Is ; i ! 2 ii II. � y \4, I _•-._._ _ ._••_ .•_ -•_•_•_ - 1- _ - - .•••-- ••._.•- •-- • -. ,._.. •- •_ - .- .. ._._ �. � � \ • • OWNER NORDSTROM, INC. 1700 7th Avenuo Suite 1000 Seattle, WA 98101 T 206 303 4300 F 206 303 4319 www.nordstrom.com • ••••••••• y - - •••• •• •• 41..• • •• . . • . n.• • ... • •• 416 616 6" a„ 12- - 6'0 8"o 10' 12- _ 12• 616 10 12" It It' r 1 C i -+, :Secla -s r• ::OW". S►xnsla ?cfer•s£r`r•2 ! 44 n =v : * C o 9 4 ' i • L : ? s!r mos • 4 AIRFLOW OI'6E OUTLET TYPICAL FAN INDUCTION TERMINAL UNIT CLEARANCE DETAIL 1 NO SCALE ROOFTOP EXHAUST FAN DETAIL (MUSHROOM STYLE) DETAIL NO SALE M -2O1 4VIW4>rNU CLEARANCE TRANE VOYAGER, ROOF CURB DETAIL 'D' VENT TOP o OU TO�i STORM COLLAR D G D 5 C DEPTH WIDTH LEN6TH CLOTHES DRYER LINT TRAP DETAIL NO SCALE V' VENT SUPPORT PER RECOIAMENDA IABAUFACTURERS N DETAIL NO SCALE — t-- RETURNAR CENTRAL PA NEL DYFASS GAS VENT O O D STAT4 PP aATAl' SCPR.YAR LID _ dz }Za n36e O D AIRFLOW SEGTION A -A F LA PTO ROUC�D SEE ARGH.PLAN FOR CURD GONSTRUGTION. 6 'INR TOP OF CURD TO FINISHED ROOF SW/ISM ROUGH GIRD OPENS* TO DE 3' YORE THAN - D' VENT OUTSIDE ML-NE WITH 5/6 PACKAED 6 r g t TR (AC-5) VAV•FIT DATE EAL VARITRAC CONTROLS FOR VOYAGER swavez DUCT TO 3' HOUNTN5 GOLL AR. SEAL JONT WITH DUCT T 5Ol1ARE TO ROUND ADAPTER SPRAY NODE WITH FLAT DI.AGK PAINT ADAPTER TO WITH SCREWS SHOWN_ SEAL WITH T TAPE SUSPENDED DETAIL NO SCALE UP TO EXHAUST FAN • , • 4'0 ALUMINUM TO DRYER VENT TYPICAL LAUNDRY EXHAUST SYSTEM TOP ENTRY LAY —IN DIFFUSER SEEPL/NFORSRE TLANFOR DOTTOY MGT. SEE PLAN OR 5Nf. TO EXCEED 7 FEET N LENGTH. MAMMA OF SO' TOTAL DI3AD PER LEN6TH TOP OF DIFFUSER FRAM TYPICAL LAY -N TYPE INLET DIFFUSER MTH GOI GTI SEE FLAN FOR 5I SEQUENCE DESCRIPTION AC UNITS (VOYAGERS AC -I THROUGIIAGBARI: VOYAGER UNITS WITH MICRO CONTROLS. EACH UNIT IS CONIHOLLEO BY A TIME OF DAY SCHEDULE. EACI1 UNIT'S OCCUPIED AND UNOCCUPIED CWUNG AND HEATING S FRMIN ARE FOLLOWING M ITS AHFA GRAPHIC ON THE TRAM' SUMMIT JI UMINAI THE FOLLOWING 1S A LIST or AREAS SERVED SY CAC/I UNIT: • AC-1 THROUGH AC-3 (SALES) AC-4 (SN.ESIDRF.SSN • AC-5 (OFFICES. TAILOR. G) DRESSING, RRFAKROOM, AND RESTROOMS) ' AC (STOCK ANI) RI:(XMNG) VTAKIJRA QVH^1;VIF,Si'{ TILE VARITRAC SYSTEM (DETAIL B) IS ACINANGEOVER BYPASS VAV SYSTEM THAT CONTROLS THE TEMPERATURE AND MODE OF INDIVIDUAL VAVi7TT ZONES, AND ALSO STAGES TIIE ROOFTOP UNIT THAT SERVES THE SYSTEM. VARITRAC SYSTEMS ARE APPI.II 1) WITH THE USE DE A VARITRAC II CI!NTRAI CONTROL PANEL (CCP) THAT PROVIDES COORDINATION. MONITORING. AND DIAGNOSTICS FOR THE VARITRACE ZONE SYSTEM. I T IS RESPONSIBLE FOR COMMUNICATING WITH. AND THE GROUPING 0F, UP 1016 YAWN UNITS TO DETERMINE SPACE HEATING AND COOLING REQUIREMENTS. AS WELL AS FOR SELECTING THE MODE AND NUMBER OF STAGES FOR 1 H HEATING AND COOLING UNIT TO MEET THOSE NEEDS. AC-51S A CONSTANT VOLUME SYSTEM THAT USES THE COMBINATION OF VARITRAC AND EMCS TO CONTROL FIT AND VAV TERMINAL UNITS. IN THE EVENT THAT THE SYSTEM BECOMES OVER- PRESSURIZEO. THE BYPASS CONTROL WILL ACTIVATE AND ALLOW THE BYPASS DAMPER TO RELIEVE TIIE PRESSURE. SPACE PRESSURE RELIEF SPACE PRESSURE IS MEASURED BY THE DIFFERENTIAL PRESSURE TRANSDUCER (DPT-1) THE LOW SIDE IS CONNECTED 70 AN OUTSIDE PRESSURE SENSOR LOCATED ON AC-5. THE HIGH SIDE 1S CONNECTED TO TIIE SALES FLOOR BUILDING PRESSURE SENSOR LOCATED BEI HIND THE AC-4 TEMPERATURE SENSOR VAV AND FIT TERMINAL UNITS AC-4 SERVES THE SALES FLOOR NiO FiT -101. FIT -10115 CONTROLLEO BY THE FMCS AND IS AUTOMATICALLY CALIBRATED WELLY THROUGH A TIME OF DAY SCHEDULE. AC-5 SERVES VAV-101, FR -t02. FIT•103, FIT-104, AND FIT-105. THESE TERMINAL UNITS ARE CONTROLLED BY THE VARITRACIEMCS AND ARE AUTOMATICALLY CAL MATED WEEKLY THROUGH A TIME OF DAY SCHEDULE. EXHAUST FANS EXHAUST FANS ARE CONTRO. LED BY EMCP OUTPUTS. SACK FANS SERVES 7HE FOLLOWING AREAS • EF -1 (MAINTENANCE CLOTHES DRYER EXHAUST) ` EE - 2 (BREAKROOM AND RESTROOMS) EF-3 (TAILOR) EF -1 IS INTERLOCKED FOR OPERATION WITH THE CLOTHES DRYER AND IS INTEGRATED 1NNT1I THE EMCS. EF 2 AND EF OPERATE ON A TIME OF DAY SCHEDULE. TRANSFER FANS IF-1 (Miry ROOM TRANSFER FAN) IS CONTROLLED BY A TEMPERATURE SENSOR. TF -1 WILL ACTIVATE WHEN ROOM TEMPERATURES RISE ABOVE 7S'F (ADJUSTABLE VIA THANE). TF-1 WILL DEACTIVATE WHEN BELOW SETPOINT. RELIEF FANS RELIEF FANS MODULATE THE EXHAUST AIR TO MAINTAIN A SLIGHT POSITIVE PRESSURE IN THE SPACE. THE RELIEF FANS ARE CONTROLLED BY THE EMCS AND ARE INTEGRATED WITH TRANE VARIABLE FREQUENCY DRIVES LOCATED IN THE UTILITY ROOM. REF -1 SERVES THE NORTH SIDE. REF-2 SERVES THE SOUTH SIDE MISC ELE ANEOUS EQUIPMENT AND CONTROL ITEMS AN ELECTRICAL PULSE METER IS WIRED TO BCU-t FOR TRACKING OF THE BUILDING'S POWER USAGE METER VALUES CAN BE FOUND UNDER THE "SETUP" DROP DOWN MENU, CALCULATION EDITOR. EMCS OVERVIEW QP_ YNbRKSTATIoN THE OPERATOR WORKST IS A 8 LL GX 150 PERSONA COMPUTER. INCLUDING A CASTLEWOOD ORB BACK-UP DRIVE AND A HEWLETT.PAGKARD 690-C INKJL I PRINTER. THE WORKSTATION IS LOCATED IN THE BUILDING MAINTENANCE OFFICE TILE OPERATING SOFTWARE IS TRACER SUMMIT FOR WINDOWS. BCU PANELS THERE IS ONE BUILDING CONTROL UNIT (ECU) LOCATED IN THE MAINTENANCE OFFICE IT CONTAINS A SOF (WARE DATABASE, AND COMMUNICATES TO DEVICES AS FOLLOWS: BCU -1: 10 ALL FIRST FLOOR FIT AND VAV BOXES PLUS THE AC UNITS AND EMCP-I. MCP PANEL BACP 1 CONTROLS THE LIGHTING CONTACTORS AND EXHAUST FANS. EACH EMCP CONTAINS ONE OR MORE TCM CONTROLLERS THAT COMMUNICATE WITH THE SUMMIT SYSTEM. THERE IS A TRANSFORMER FOR EACH TCM PLUS ONE PROVIDING THE 24 VAC POWER USED TO DRIVE THE PILOT RELAYS. EACH OUTPUT IS WIRED TO A 24 VAC PILOT RELAY, WHICN W TURN CONTROLS ITS LOAD. IN THE CASE OF LIGHTS, THERE IS A 120 VAC LIGHTING CONTACTOR THREE PHASE EXHAUST FANS RELAYS ARE WIRED TO THE AUTO POSITION OF FAN STARTERS. SINGLE -PHASE DO R= FANS HAVE PILOT RELAYS DRMNG POWER RELAYS RATED FOR THE FAN MOTOR ALL OUTPUTS ARE WIRED TO DEFAULT TO T HE ON STATE 19 THE EVENT OF CONTROL POWER LOSS TIES IS ACCOMPLISHED BY HAVE4G THE ON COMMAND FROM THE EMCP REMOVE THE 24 VAC SENT TO ITS LOT RELAY_ THEREFORE WHEN THE SUMMIT COMMAEMS AN OUTPUT ON. THERE IS 0 VOLTS TO THE PILOT RELAY FROW THE EMCP TERMINAL WHEN IT IS COLT+ 7ANDED OFF, THERE 1S 24 VAC TO THE PILOT THERE IS ALSO A LIGHTING OVERRIDE PANEL LOCATED ON EMCP-1. AC UNITS (VOYAGER) THESE UNITS HAVE VOYAGER 1 MICRO CONTROLLERS. EACH UNIT HAS A SPACE SENSOR. DISCHARGE SENSOR ANo DIFFERENTIAL PRESSURE SWITCHES FOR FAN AND FILTER STATUS. LIGHTING NUMEROUS TOO (TIME OF OM) SCHEDULES CONTROL LIGHTING AREAS SY USE. THE SCHEDULES CONTROL THE AREA LIGHTING VALUE. EACH FLOOR HAS AN AREA FOR LIGHTS REQUIRED AT STORE OPENING (X FLR STORE OPEN LIGHTS AREA), AN AREA FOR V2 OF THE FLUORESCENT LIGHTS IX FLR CLEANING LIARS AREA A). ANOTHER FOR THE OTHER HALF OF THE FLUORESCENTS (X FLR CLEANING LIGHTS AREA 6). AMORE FOR DRESSING ROOM AM TOILET ROOM LIGHTS (X FLR DRESSING ROOM LTSAREA). THE TWO CLEANING UM' AREAS SHOAL D 8E ALTERNATED DAILY THROUGH THEIR TIME OF WWY Sant/ES TO PROVIDE EMT USAGE MINE FIXTURES. THE DRESSING ROOM LIGHTS ARE SCHEDULED EVERY NIGHT WITH CLEANING UGHTS. OUTSIDE SIGNS ANO L KNITS. IN AN AREA CALLED'PNOTOCO L WI TIME CONTROL AREA'. ARE CONTROLLED USING A PHOTOCELL DETECTING PNNT LIGHT" PLUS A IRE OF DAY SCHEDULE. THE PHOTOCELL OUTPUT VALUE IS CO►IPARED TO THE ADJUST SETPOINT CALLED LIGHTING LEVEL SETPF TO DETERMINE F EXTERIOR WILTS AND SIGNS ARE REQUIRED. Bur THEY ARE ONLY ALLOWED ON DURING THE PERIOD DEFINED N THE TUBE OF DAY S(I OU.E CALLED 'PHOTOCELL TIME OF OM SCHEDULE" THERE IS ALSO AN AREA CALLED PHDTOCERL CONTROL ONLY AREA VIIIIE t IS CURRENTLY CONTRROLU: NIG THE LOADING DOCK LIGHTS USING THE PROTOCOL OILY. WITH NO TILIE OF DAY SCHEDULE_ Ti E EMCP PANEL HAS A MANUAL OVERRIDE SWITCH OTSDE FOR arcRGENCY USE OILY. WI EN THE SWITCH IS ON. THE SWV.1IT CONTROL IS BYPASSED AND ALL OUTPUTS FROM THE PANEL TOW ON (BECAUSE THE 24 VAC PLOT RELAY COL 1111TN5E 15 R 0). FAGh EMGP'S BINARY INPUT EICP•X MANUAL OVERRIDE SNITCH' WIUL INDICATE AN ALARM E ITS SWITCH IS USW TO MANUALLY OVERREE AM THE LIGHTS IN MN AREA. CONTROL THE AREA LIGHTING VALUE TOACTIVE OR INACTIVE. TO MANUALLY OVERRIDE A SINGLE CONTACTOR, CONTROL THE CONTACTORS MARY OUTPUT PRESENT VALUE TTOACTNE OR INACTIVE • • 1 REVIEWED I'OFC . CODE COMPUA1iCE APPROVED MAY'Q OLyOf Adel a BUILD DIVJ 1Q' P11 i ; O z O tir) M -201 A Z M SI CO a N 3 • O U l o co d � O ~ � c O ii a H cno • -. N O E 4 > L roo _ .( 0 0 ▪ =3C,� a O N (Ns - U � eo a> m :.o ®o J o'- 00 3 4 v0 NN 3 O tot- et. 3 0 0 0 0 1- 0 N MI am 2 3 z 0 ISSUED 1 REVISED DATE SID/PERYIT SET 03/06/07 NVAC SECTIONS AND DETAILS AND SEQUENCE OF OPERATIONS 7 1