Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-120 - WESTFIELD SOUTHCENTER MALL - PARKING GARAGE A
WESTFIELD PARKING GARAGE A 633 SOUThCENTER MALL M07 -120 Parcel No.: 2623049023 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 633 SOUTHCENTER MALL TUKW Contact Person: Name: PEGGY PEEL Address: 4600 S 134 PL , SEATTLE WA Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA Contractor License No: HOLADPI379NO DESCRIPTION OF WORK: INSTALLING 1 ROOF TOP HEAT PUMP Value of Mechanical: $6,882.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM > 10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us WESTFIELD - PARKING GARAGE A 633 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BL , LOS ANGELES CA MECHANICAL PERMIT Fees Collected: $235.00 International Mechanical Code Edition: 2003 EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: M07 -120 Issue Date: 06/07/2007 Permit Expires On: 12/04/2007 Phone: Phone: 206 - 248 -8747 Phone: 206 248 -9700 Expiration Date: 09/03/2007 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 2 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -120 Printed: 06-07 -2007 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting • • ' - _ • not pres a to give uthority to violate or cancel the provisions of any other state or local laws regulating construction f work. I am autho ized to sign and obtain this mechanical permit. doc: IMC-10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -120 Issue Date: 06/07/2007 Permit Expires On: 12/04/2007 Date: ( o 7 Date: (-i r- 7 - O This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende( or abandoned for a period of 180 days from the last inspection. M07 -120 Printed: 06-07 -2007 Parcel No.: 2623049023 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 633 SOUTHCENTER MALL TUKW WESTFIELD - PARKING GARAGE A PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -120 ISSUED 06/01/2007 06/07/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** M07 -120 Printed: 06-07 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating constructio - e performance of work. i 1 Signature: L — 7 -67 .��► � Date: � ,p 0 _ 1 Print Name: t� . 1� >' k, 6 ✓l VL -G doc: Cond -10/06 M07 -120 Printed: 06-07 -2007 E -Mail Address: Company Name: Mailing Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cLtukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 633 Tenant Name: Property Owners Name: Mailing Address Name: ( �' - ��� Mailing Address: $6'o S. /3 —` ' / 3' Company Name: --// o Mailing Address: Y'teB Contact Person: 0....,2-21/7- 0 E -Mail Address: p e.y yi0 € `re)/ mdet ypa . Co vh Contractor Registration Number: j/ 1 . i D Pr 3 71 ilk s / Contact Person: E -Mail Address: Contact Person: E -Mail Address: QMpplicaeonslforms- Applications On Linc3.2006 - Permit Applicaiion.doc Rnniscd: 4-2016 bh w TUKWILA w Public :Woi or ofce:ise only King Co Assessor's Tax No.: Suite Number: City New Tenant: State Day Telephone: aD - Li g - g 717 &J,4. 9g/h f City State Zip Fax Number: o?D 6 ' S " g 70 0 GENERAL CONTRACTOR INFORMATI (Contractor Information forMechanical(pg 4) for Plumbing and Gas Piping r(pg City Day Telephone: Fax Number: Expiration Date: Floor: aker.les Zip w.4 V? /6 g State Zip aa6 - 2 4 /2 - g 747 •?o/, aa 9107 ARCH • Off' RECORD Al l plans 'must be wet stamped by Architect of Record State Zip City Day Telephone: Fax Number: ENGINEER OF RECORD = All plans must be wet stamped by Engineer of Record State Zip City Day Telephone: Fax Number: Page 1 of 6 Unit Type: Qty Unit Type: Qty . Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment Mailing Address: Contact Person: C. E -Mail Address: e_ Contractor Registration Number: MECHANICAL CONTRACTOR INFORM TION Company Name ___ /E / - 4 � 4ov S. /34= - pee I i t V L htoc19D P2 379 4 Valuation of Project (contractor's bid price): $ t1S .. a Scope of Work (.i ase provide detailed information): of mechanical work being installed and the quantity below: Q:,Apphcations\ronns- Applications On Line3-2006 - Pemd Apphcationdoc Revised: 4 -2006 bh City Day Telephone: Fax Number: Expiration Date: tdr9- i7/6g State Zip o744, -a21g• '' ? 9/0 7 Use: Residential: New .... ❑ Replacement .... 0 Commercial: New .... Replacement .... ❑ Fuel Type: Electric as••••❑ Other: Page 4 of 6 PE RMIT APPLICATION NOTES Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI Signature: Print Name: �e- I fly �e e / Q Mailing Address: 'fie Do S , /3' Date Application Accepted: 19-1 -07 Date Application Expires: — ... 0 ^7 Staff Initials: 0 1 Q: Applications .Forms - Applications On Linc 3 -2006 - Pcnnit Application.doc Rcviscd: 4 -2006 1.11 Date: S /.3 //D 7 Day Telephone: 020 7 It)/9 9' /LP City' State Zip Page 6 of 6 Receipt No.: R07.01072 Payee: HOLADAY -PARKS INC ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: M07 -120 Address: 633 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/01/2007 Applicant: WESTFIELD - PARKING GARAGE A Issue Date: Initials: WER Payment Date: 06/07/2007 03:37 PM User ID: 1655 Balance: 50.00 TRANSACTION LIST: Type Method Description Amount Payment Check 159909 194.00 Account Code Current Pmts 000/322.100 194.00 Total: $194.00 Payment Amount: $194.00 9093 06/07 9716 TOTAL 388.00 doc: Receiot -06 Printed: 06 -07 -2007 Parcel No.: 2623049023 Permit Number: M07 -120 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/01/2007 Applicant: PARKING GARAGE A Issue Date: Receipt No.: R07 -00993 Initials: WER Payment Date: 06/01/2007 11:16 AM User ID: 1655 Balance: $194.00 Payee: HOLADAY-PARICS INC TRANSACTION LIST: Type Method Description Amount Payment Check 159894 41.00 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 41.00 Total: $41.00 Payment Amount: $41.00 8824 06/01 9716 TOTAL 82.00 doc: Receiot -06 Printed: 06-01 -2007 Protect: < s 11/f /c/ ' / Z. V 4 Type of Inspection: `i /V‘i / N.- Address: -3 3 $d) ' /(r,1 ' Date Called: / Special Instructions: Date Wanted: O /'a. m. WTI. Requester: Phone No: ,--,2 6 - 050 y/ V INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit COMMENTS: pot, h AN) (:? U p , /.M, p l iO / /iN4i nspector l Z/ A. t IDate I Rec pt No.: 'Date: �8 �0 REINSPECTION FEE ' EQUIRED,,Fs nor to inspection. fee must be d at 6300 Southcenter Blv . ., Suite O. Calt the schedule reinspection. 7)1? /Z El Corrections required prior to approval. COUGHLINPORTERLUNDEEN A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION Structural Calculations for the Pi_ Westfield Southcenter Parking Structures (Heat Pump Addition) FSI Architects 5 -22 -2007 S05- 1622 -01 BUIL Of Tukwila ING DIVISION I EXPIRES 7/25/07 Prepared by: Brian MacRae t4O7 1W FILE copy REVIEWED CODE COMPLIANCE APPROVED JUN - 5 2007 RECEIVED JUN - 12007 PERMIT CENTER C D 2 a a u Project: Project No. mat PLmp 7 w 7I1 ° /Ors f (peek + FrNn., F r►„s c Lt._ YO Seiym;c fp= D.Kap Snt ( pi. a "/k nr/ it 200( 7C 6zs >uc-fs (o.ls)(6).s' = Ty # -6 /1= 3(1.1 GCde. 600 .041-- 9f Ic-,n 0iL V = 0.� l/ui401.v= (z)(z.l) - S.1' A - °S2" L /3w / CI ��L (L) S'�tcrevs-s Vr.4Io ,,= (6)(1.6 z 1.6 �` o� " Of) 3//4'� 174,0, Sc k rew 0 Sow.. - P c e fie.- Gam.v eS Client: Ot ' xs.$) = gb yxio 1 a • 75' p� 1,M oidt Sa 2,D s•s L L LVs = ror, / S =6 " 3s 413 PINE STREET • SUITE 300 • SEATTLE. WA 98101 • P: 206/343 -0460 • F: 206/343 -5691 COUGHLINPORTERLUNDEEh STRUCTURAL - CIVIL • SEISMIC ENGINEERINI 4,z/,o Igpt a•a Hv AL 4 s,'. (a Ak er 1 1- ABLE 4. f;. 3, Designed By: g J. P Date: 2.10 Checked By: Sheet of Rev: 580003 User. KW- 0602151 Ver 5.8.0, 1-Nov -2006 (c)1983 -2006 ENERCALC Engineering Software Description Center Span Left Cantilever Right Cantilever [Trapezoidal Loads Magnitude © Left Magnitude @ Right Dist. To Left Side Dist. To Right Side Query Values Center Location Moment Shear Deflection Summary 13.00 ft ft ft Maximum = 2.87 k -ft 0.100 k/ft ft 3.750 ft 0.000 ft 0.00 k -ft 0.80 k 0.00000 in Moment of Inertia Elastic Modulus Beam End Fixity Moments... Max + @ Center 2.87 k -ft at 6.51 ft Max - @ Center 0.00 k -ft at 0.00 ft © Left Cant 0.00 k -ft © Right Cant 0.00 k -ft 0.154 k/ft 0.154 k/ft 3.750 ft 9.250 ft Left Cant Shears... © Left © Right Maximum Deflections... © Center @ Left Cant. © Right Cant Title : Dsgnr: Description : Scope : Single Span Beam Analysis 5.720 in4 29,000 ksi Pin -Pin 0.000 ft 0.00 k -ft 0.00 k 0.00000 in 0.80 k 0.80 k 0.80 k 0.100 k/ft 0.100 k/ft 9.250 ft 13.000 ft Job # Date: 1:48PM, 22 MAY 07 Right Cant Reactions... © Left © Right -0.518 in at 6.51 ft 0.000 in at 0.00 ft 0.000 in at 0.00 ft k/ft k/ft ft ft Page 0.000 ft 0.00 k -ft 0.00 k 0.00000 in 0.80 k 0.80 k ACTIVITY NUMBER: M07 -120 DATE: 06 -01 -07 PROJECT NAME: PARKING GARAGE A SITE ADDRESS: 633 SOUTHCENTER MALL X Original Plan Submittal _ Response to Correction Letter #_ Response to Incomplete Letter # Revision # After Permit Issued DEPARTM NTS: ✓�v�� Bul.11 g 'vision Public Works ri DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT G: Please Route REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Documents /routing slIp.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 611 IVA/ Fire Prevention A Planning Division E Structural ❑ Permit Coordinator ❑ Incomplete Structural Review Required El DUE DATE: 06-05-07 Not Applicable No further Review Required DUE DATE: 07 -03 -07 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HOLADPI379NO Licensee Name HOLADAY PARKS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 578004089 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 69208 Address 2 City SEATTLE County KING State WA Zip 98188 Phone 2062489700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/21/1983 Expiration Date 9/3/2007 Suspend Date Separation Date Parent Company Previous License HOLADPF376NO Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD T JR 01/01/1980 PARKS, DAVID L 01/01/1980 TALBOT, PAUL 01/01/1980 NELSON, MICHAEL 01/01/1980 BECK, DAVE 01/01/1980 OCONNOR, BONNY K 01/01/1980 NAILON, JUNE A 01/01/1980 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. I Bond Information I https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HOLADPI379NO 06/07/2007 BASIS OF DESIGN DESIGN CRITERIA CRITERIA SOURCE 1 2003 NTENNAiIONAL BUILDING CODE EFFECTIVE AlGUST 15, 2004 2 2003 INTERNATIONAL TECHNICAL CODE EFFECTIVE NKXIST 15, 2004 3 2003 WSEC (CHAPTER 51 -11 WAC) EFFEOTWE AUGUST 15, 2004 4 2003 ISVIAQ CODE SECTIONS 202 & 203 EFFECTIVE AUGUST 15, 2004 5 OSA DESIGN TEMP = 83'F DB, 6TF IS 6 ISA DESIGN TEMP = 50 HEATING 80'F COOLING 7 EQQUIRENT LOAD = 36 MBH PER PROPOSAL. a • GENERAL NOTES 1. TILL TRADES TO LEAVE 36' CLEARANCE IN FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 2. CUT flNG, FRAYING PATCHING NO PAINING OF WALL, CEILNG AND FLOOR OPENINGS SHALL BE BY CEEtAL CONTRACTOR 3. FINAL PAWNING OF GRILLES, REGISTERS,, MD DIFF1USERS, AS MAY BE REQUIRED BY ARCHITECT, SHALL BE DONE BY GEWRAL CONTRACTOR 4. GENERA. CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DUNNING CONSTRUCTION. 5. UNIT SMUTS ND LOCATIONS HAVE BEEN COORDINATED Will ARCHITECT MO STRUCTURAL DOWER TO DETER UIL BUILDING STRUCTURAL ADEQUACY. IF IT IS NECESSARY TO RELOCATE A UNIT, NOTIFY HOLIDAY -PARKS' ENGINEERING DEPARTMENT FOR I E- COORONATION. 6. N NO INSTANCE SHALL OTHER TRADES HANG OR SUPPORT EQUIPMENT, CEEIIG STIES, LIGHT FIXTURE HANGERS, ETC, FROM HVAC EQUIPMENT OR DUCTWORK 7. PLUMBER SWILL ROUTE PLURBING VENTS SO AS TO MAINTAIN MINIMUM 15 FEET OF CLEARANCE FROM OUTSIDE AIR INTAKES. ELECTRICAL COORDINATION NOTES 1. II}ERE INDICATED ON EQUIPMENT SCIEDUES, THE EQUIPMENT COMES COMPLETE FROM THE FACTORY SM1H MOTOR CONTROLS AS REQUIRED. ELECTRICIAN SHALL PROVDE SERVICE AND A DISCOMECT PER COOL AND DO ALL POWER WRING. NCUIDING COMECTiNG TO EQUIPMENT. 2. WHERE INDICATED ON EQUIPMENT SCHEDULES,, THE EQUN'MENT REQUIRES FIELD NSTAlEO MOTOR STARTERS. ELECTRICAL CONTRACTOR SHALL FURNISH NO INSTALL MOTOR STARTERS (OR CONTACTORS 1NERE INDICATED). PROVER SERVICE MD DISCONNECT PER CODE, AND Do ALL POSER WRING NCULDNG COMECTNG TO EQUIPMENT. HOLDING COIL CIRCUIT SHAL BE POWERED BY ELECTRICAL CONTRACTOR (120 VOLT /1 PH. UNLESS INDICATED OTHERWISE). ALL STARTERS SHALL BE PROVDED WITH 11-0-A SWATCH, 3. 2 - 120V CONTROL CROUTS PER FLOOR ARE REQUIRED E.C. SHALL PROVIDE SERVICE AND A DISCONNECT PER CODE, AND DO ALL POWER WRING, "ELUDING CONNECTING TO CONTROLS CONTRACTOR PROVIDED TRANSFORMERS AND EQU FI ENT. SEISMIC RESTRAINING NOTES 1. ANY BASE- MOINNJED/SPRNG- MOUNTED EQiIFHENT SHALL HAW TOTALLY ENCLOSED, SEISMIC RATED SPRINGS (MASON MODET. SSLFH OR EQUAL), OR OPEN SPRINGS PLUS SEISMIC 'SNUBBERS' (MASON MODEL Z -1225 OR EQUAL). 2. P11 SPRING MOUNTED, SUSPENDED E UIR ENT SHALL HAVE SEISMIC CABLES INSTALLED N ADDITION TO EQUIPMENT HANGERS. CABLES SHALL BE INSTALLED DIAGONALLY UP MD AWAY FROM EQUIPMENT CORNERS NO BE ATTACHED TO THE STRUCTURE ABOVE CABLES SHILL BE LEFT PARTIALLY SLACK SUE MD INSTALL CABLES PER SITPOTA SEISMIC RESTRAINT MANUAH.. 3. ANY EQUIRENT MOUNTED WOOLY TO THE BUILDING STRUCTURE SHALL NOT REQUIRE AMORAL SEISMIC RESTRA/NIT. 4. RESTRAIN ALL RECTMIGUIIR DUCTS 6 SQ. FT. OF AREA MD LARGER NO ALL ROM DUCTS 28' 11 DIAMETER NO LARGER RESTRAINTS SHALL. OCCUR 30 FEET 0.C. NA MUM MD SHALL BE INSTALLED AT EVERY DUCT TURN NW AT THE EM) OF THE DUCT WE SIZE MD INSTAL RESTRAINTS PER SMACNA SEISMIC RES1RMR MANii & 5. AiL CEILING MOUNTED DIFFUSERS SHALL HAVE TIRES (16 GA.) ATTACHED TO THE ABOVE FLOOR SLAT OR STRUCTURE SAFETY SIRES SHALL BE LEFT PARTIALLY SLACK ALTERNATE 11(11100 SHALL BE TO ATTACH OFFUSERS TO T-BAR GRID NTH scans, RIVETS, OR C OUITG CUPS FOR TEIMW S SIEiGHNG LESS THIN 20 POUNDS` SHEET METAL. NOTES 1. DUCT SUES INDICATED ON PLANS ARE NET RISME DIMENSIONS. A CAL -OUT SUCH AS 12' X 12/SL MEANS A 14' X 14' SHEET METAL DUCT vim 1' SOUNDLKR GIVING A NET INSIDE DIMENSION OF 1r X 1r. 2. 1FROUG H PENETRATION AND IMEMBRRNE PENETRATION FIE STOP AS WOWED ED N TIE UBC SHALL BE PROVIDED NO IISTAU.ED BY TIE T ECIIICA. CONTRACTOR. RE STOP SYSTEM SEAL BE 311 BROW FIE BAR CP 251ST mimic OR APPROVED EQUIVALENT. NOTE PER UMBC 714 EXCEPTIONS FARE AND COMTOIA1ION FIE NO SMOTE DAMPERS SHALL BE NSTAlED N ACCORDNICE SIKH TIER USTNGS. MMNIFACTURER INSTNIATTON INSTRUCTIONS 00 NOT REQUIRE FIRE STOP BETWEEN SLEEVE NO ASSEMBLY PENETRATED. 3. DUCTWORK SHALL BE CONSTRUCTED TO DIEHSIONS INDICATED ON PING 'DE TOLERANCE OF THESE DIENSIONS SHALL iE AS SPECIFIED N NOWAY-PARKS, NC. SHOP STANDARDS MANUAL LENGTHS, NO CRITICAL DIMENSIONS 8ETINB4 DUCTNR( MD OTHER BOWING/SYSTEM MEATS ARE INDICATED WEE A LOCATION OR MOON SCALED FROM TIE DRUM S L NOT BE ADEQUATE TIE TOLERANCE OF CRITICAL DIENSIONS% F NOT RNICA1ED, SHIN, DEFAULT TO THAT OF DE WALING RECTUM'S REAMING DEVICES. SCALD LOCATIONS OR 011010015 AWE NOT SUBJECT TO TOLERIWCE =ELKS. 4. DESE PLANS HAW ®Ni COMMAND SMITH DE MIC IIECiIRtN,. S R CTUUI. SPENSER MO ELECTRICAL DRAMS. ANY PURGES N DRS LAY -OUT i1UST BE REVERED BY HOLIDAY -PARKS' DOWERING DEPAFRTIENT f it 11 bcd / 1 12 x 12 1 4 -( 3 HR - .3 Il I - 12x12/5, J 12x12 / / 12,42/W / Y 38,244 INIMNIMIM■11* HVAC LEGEND DUCT MINER POSIi1VE PRESSURE DUCT UNDER NEGATIVE PRESSURE TURNING VANES ELEVATION FROM F.F.L. (INSULATION MD DUCT FLANGES EXTEND '1S' 8110W BOD CALLOUT) EQUIPMENT IDENTIFICATION THERMOSTAT IOSSTAT SENSOR S.SG. SODOM SUPPLY GRIUE DOUBLE DEFECTION, HOiIZONTAL FRONT BLADES TAUS MODEL 272RL - KRUEGER MODEL 88011 S.R.G. SDEWALL RETURN GRILLE FIXED 35 DEGREE DEFLECTION BLADES, WITHOUT GOD TiTUS MODEL 350RL - KRUEGER MODEL 58011 SUPPLY AIR ARROW RETURN AR ARROW SPEED SWATCH: FURNISHED BY HHOLADAY- PARKS, INSTALLED BY ELECIR CONTR. FLEXIBLE CONFECTION DUCT HEATER MAINA. VOLUME DAMPER MOTORIZED DAMPER BACK ORAFT DAMPER SMOKE DETECTOR VERTICAL FIRE DAMPER (114 HOUR) IN AIRSTREAM RUSION! MODEL 0182 STYLE A HORIZONTAL FARE DAMPER (114 HOUR) N MISTREAT RUSKN MODEL I B2 STYLE A VERTICAL FiRE DAMPER (3 HOUR) IN AIRSTREAM RUSKIN MODEL 0m23 STYLE A VERTICAL RE DAMPER (3 HOUR) N ARSiREAV RUSKIN MODEL 01823 STYLE A BACK DRAFT DAMPER RUSKIN MODEL 002/A1, LOCAL VELOCITY < 1500 FPM BACK ORAFT DAMPER RUSKN MODEL BD2/A2, LOCAL VELOCITY < 2500 FPM BACK DRAFT DAMPER RUM MODEL 806, LOCAL VELOCITY < 3500 FFM SMOKE DAMPER HORIZONTAL VERTICAL CATION SMOKE AND FIRE DAMPER VERTICAL COMBINAilON SMOKE MD FiRE DAMPER SPIN-11 TAKE -OFF & VODUME DAMPER INDICATES 14' x 14' 0.0. SEEDED/ ETA, M H 1' SOMLMER (WW1 x 1r NET L0. ROCKIES Ulna 12'x12' SIT. DUCT iDCATES 1r x 12' ID. DUCTBOAD INDICATES OARED 12' x 12' S.Y. DUCT SMITH INSULATED 11UP RISE OR DROP N DIRECTION OF FLOW RUSE DUCT INDICATES RAT OVAL DUCT SAWN TAKE -OFF & YOUR( DAMPEN SRAM! RIGID ROUND FIBERGLASS DUCT T�F' THE GARAGE i THE Pi • II , I • ®-a S.G SUPPLY AIR GRILLE DOUBLE DEFLECTION. FRONT BLADES PARALLEL TO THE SHORT DIMENSION THUS MODEL 300 FS RAG. RETURN AR GRILLE ALUMINUM EGOCRATE YAM W x W x Ye CORE RTUS MODE 50F - KRUEGER EG-5 - A � a ∎'I• A A - o: AFF AP BHP BOU COWL DIES. ON. DR. EA EAT E.C. ESP FD GRILLES, REGISTERS, DIFFUSERS LEGEND FFL FUSSED FLOOR LEVEL FAA FULL LOAD AMPS RR DR. FLOOR DRAIN FOB FLAT ON BOTTOM FOT FLAT ON TOP FUT FUTURE GC GENERA. CONTRACTOR 1: 2: 3: 4: 5: 6. S.S.G. SDEWALL SUFFIX GRILLE DOUBLE DEFLECTION, HORIZONTAL FRONT BLADES TUTUS MODEL 272111. - KRIEGER MODEL 88011 S.R.G. SIDEWALL RETURN GRILLE FIXED 35 DEGREE DEFLECTION BLADES, 1NTHOUT OBD Y ABOVE FINSIED FLOOR ACCESS PANEL BACK DRAFT DAMPER BRAKE HORSE POWER BOTTOM OF UNIT CONNECT/COMMON DAMPER DOM DRAIN EACH ENTERING Alit TEMP ELECTRICAL CONTRACTOR ELEVATION EXTERNAL STATIC PRESSURE FARE DAMPER HVAC ABBREVIATIONS IN NSUL UT MCA N/A NC NC NO NOM. NTS OA OD PRSM PSi RA SA SM SP UP W/ HORSE POSER INSIDE DIMENSION/DIAMETER INSULATION LENANG AR TEMP MOIMW ROUT AMPACOTY NOT APPLICABLE NORMALLY CLOSED NOT 11 CONTRACT NORMALLY OPEN NOMINAL NOT TO SCALE OUTSIDE AR OUTSIDE DI PRIMARY rEi�(Oti POUNDS PER SQUARE INCH RISE RETURN AR SUPPLY AIR SHEET METAL STATIC PRESSURE TYPICAL VOLUME DAMPER NTH LEGAL DESCRIPTION 13 INTERURBAN ADD TO SEATiLE POR OF SE 14 OF SW 14 OF SEC 23 -23-04 -- BEG SW COR OF SE 14TH N 89 -40 -24 W 65.40 FT TH N 00 -19-36 E 40 FT TO TPOB TH CONTG N 00 -19-36 E 110 FT DI N 89 -40-24 W 151.60 FT DI S 00 -19-36 W 110 FT TH S 89 -40 -24 E 151.60 FT TO TPOB HEAT PUMP SCHEDULE IP # AREA SERVED MODEL COMING TOTAL SEI HTG. CAP MBH FAN PERFORMANCE DATA HTR. ELECTRICAL KW V/p11 MT. OR COP FILiERS SiZE REIMS raw MHP QTY a.. \ •V •>: J IIHP -1 ELEV YACHHiNE RHI TRADE VISCO36(1 37.65 2706 111M111 1200 QS 826 034 IEM d 230/1 1 691 N 264 COOLING CAPACITY N LOH AT 80 'F DB / 67 'F 1118, 95'F DB OUTDOORS T'EA= CAPACITY N MENU AT 70 'F 08 INDOOR, & 20° F OUTDOOR NCCESSO ES NCLLDE: LOW AMBIENT TOT POSER SIRING AND DISCOMECT PROVIDED NO INSTALLED BY EC. T -STAT S IA . 8E FRONDED ND INSTALLED BY CONTROLS CONTRACTOR (M.C.) SEER IS RATED AT AM CONDITIONS AND N A CORAONGE SMTH DOE TEST PROCEDURE • SEPARATE PERMIT REQUIRED POT: e Nediarical WrEledskal lifPlunbing C'ty of i uk,' a BUILDING DIVISION inDaSIMIS No changes Man b• made to the sco C: Weft without prior appro- o! cf i:.''; .1:b Build!ns c ;'? ::• �. I - .�.. • • t .>� ONO SCOPE OF WORK 1. INSTALL (1) NEW 3 TON WALL MOUNTED SELF - CONTAINED TEAT PUMP. 2. INSTALL STAND-ALOAE THERMOSTAT AS SHORN. 3. INSTAL MD (2) WALL SLEEVES, ONE (1) SUPPLY CIRI.LE NO ONE (1) RETURN GRILLE AS SHOWN. 4. START, TEST & ADJUST SYSTEM. FENCE OF OPERATION HEAT PUMP TO OPERATE BASED ON STAND -ALONE THERMOSTAT. ALL OTHER EXISTING EQUIPMENT PER BOWING STANDARD. SCOPE OF WORK-REVISION 11 1. REMOVE 3 TON WALL MOUNTED HEAT PUMP SEWING ACCESSORIES. 2. INSTALL (1) NEW 3 TON ROOF MOUNTED HEAT PUMP UUI11 KITH ROOF CURB, ECONOMIZER BACK-UP ELECTRIC HEAT & CONTROL 3. NSTALLL STAND -ALONE 1IERMOSTAT AS SHORN. 4. INSTALL ONE (1) SUPPLY GRILLE, AND ONE (1) RETURN GRIlE/OPEJI NAG SiTH SCREEN AS SHOW 5. START. TEST & ADJUST SYSTEM. *m NW DA1118 cf :.L`71TOtIRY c wale 'AT Cy;, ?JI' TM) Df:IEFIcoSV1 .J rarwr'(,ws D OCAIWVSATTICIED a sy . s L COUGHLIN PORTER LUNDEEN, INC. Cor=`tin9 10T Sea'-'e. Washington 98101 Mop -12 Q Plan review approval Ls subject to eios and amtsslosi. Approval of ar uctdon demonists does not allsorta the vlotark.. c.. tsry - • . or Of kfan e. t Oh F ;.y • . ' .. - b • ... Nedgat BY Adriirm. 0 - Y) CJty of Tukwila BUILDING DIVISION APPROVED FOR CONSTRUCTION RECEIVEG t ' 2007 PERMIT CENTRE O d TM PENDNJG CITY APPROVAL 9 i 0 1 ■it iv ki ix it qic 4 ' daitr o f -Or- >1wIMoEEc 5 /3/07 ow Rs saw M001 ' M0.01 < a 6 ig 6 5 !• tin • r t a1j, X ■f 1 f■ t - V/Ml HEAT PUMP ' LP1Y : L IF. rro1K CZATR14GTak I BC6IN BLEND SLOPE 6% MAX BE6IN MAIN RIJN 510PE 10% MAX b1 b � d� I THIGKD D TO DRIP -LHE VON O.NT5 FRST FLOOR HVAC PLAN Soda VW • i-0' L I 5 jar r Ace( GOKIGTO4 I parame WI TO IDOEP ELEVATION Sods: 1/8' • Fir 11 4? JT4 CO i ELEV. MACH-NNE RM ROOF PLAN Sails: VW • 1-0° 1 t C P :)(2N r' MAWS NEP DA aft O KEYED NOTES �lt� - -I2o 1. - SHEET NOTES RECEIVE( uL1 -1 2i1.17 PERMi' CENT t: 11•11■111 1•111 LFETYPE LEGEND = DOSING CONNEXION = . NEW CONSTRUCTION - RIME CONSTIiiNCAON ` -` r- = OEZUTION M4Y i ' [ = 1EDNPMf BOIONDARV PENDING CITY APPROVAL APPROVED FOR CONSTRUCTION "oda 6 ? G i s f I i i 1< J O/ 4 M NM wMire 5/3/07 M2.01 It a A 116 Ric i t�. �g �o K1 ig 1 •� L f 4 c I § <ffi 0 co -e I 9 ) FA O esdiMb maw s M201 • • • 1