DESCRIPTION OF WORK:
REPLACE (1) 4 TON ROOFTOP UNIT
Value of Mechanical: $11,800.00
Type of Fire Protection:
Cityf Tukwila
BASCO
6750S 180 ST , TUHWILA WA
AMC FAMILY LLC
PO BOX 2720 , PORTLAND OR
Contact Person:
Name: TIM HOLLIPETER
Address: 6603 N E 137 AV , VANCOUVER WA
Contractor:
Name: TRI -TECH HEATING INC
Address: 6603 NE 137Th AVE , VANCOUVER WA
Contractor License No: TRITEHI952LL
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
doc: IMG10 /06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 - 3665
Web site: http: //www.ci.tukwila.wa.us
MECHANICAL PERMIT
EOUIPMENT TYPE AND OUANTITY
0
0
0
0
0
1
0
0
0
0
0
0
0
0
* *continued on next page **
M07 -122
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 360 -907 -7413
Phone:
Expiration Date: 06/13/2009
M07 -122
06/08/2007
12/05/2007
Fees Collected: $292.63
International Mechanical Code Edition: 2003
Boiler Compressor:
0-3 HP /100,000 BTU 0
3-16 HP /600,000 BTU 0
15-30 HP /1,000,000 BTU.. 0
30-50 HP /1,750,000 BTU.. 0
50+ HP/1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 1
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment 0
Printed: 06-08 -2007
Permit Center Authorized Signature: 7
Signature:
doc: IMG10 /06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: M07 -122
Issue Date: 06/08/2007
Permit Expires On: 12/05/2007
Date: ri l vU j -
I hereby certify that I have read and xanjmed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied , whether specified herein or not.
The granting of this pe does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
constru 'e = ce • ork. I am a _ orized to sign and obtain this mechanical permit.
Date:
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende4
or abandoned for a period of 180 days from the last inspection.
M07 -122 Printed: 06-08 -2007
Parcel No.: 3523049095
Address: 6750 S 180 ST TUKW
Suite No:
Tenant: BASCO
1: ** *BUILDING DEPARTMENT CONDITIONS * **
1u✓
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number: M07 -122
Status: ISSUED
Applied Date: 06/01/2007
Issue Date: 06/08/2007
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Readily accessible access to roof mounted equipment is required.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
T: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
8: Manufacturers installation instructions shall be available on the job site at the time of inspection.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206 - 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Cond -10/06
* *continued on next page **
M07 -122 Printed: 06-08 -2007
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the perf • rmance of work.
Signa
Print Name:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Date &' a D
M07 -122 Printed: 06-08 -2007
CITY OF TUKf'A
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://wwwatukwila.wa.us
Company Namc:
Mailing Address:
Contact Person: /
E -Mail Address: 666
Q:MpptiestionsWonn Application On uno13-2006- Permit Applie tion.doc
Revised: 9 -2006
bh
Building Permit No.
Mechanical Permit No. I" n
07
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
'(3 , ASe.o
Tenant Name:
Property Owners Name: (�
Mailing Address: !/ SO C t u V
Contact Person:
E -Mail Address:
•
—1—U-V vc
City
City
3,5).301-,1909 -
__ { (� . King Co Assessor's Tax No.:
//
Site Address: l9 75 S . I v0 Suite Number: Floor:
New Tenant: ❑ Yes ix,,.
(A) . ct 3l 9�
S tate Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: Tim tk O 1h Day Telephone: 3( go
Mailing Address: ID SOD l3 �. U11 v Roe 0000144 wet- 1 € 6,0 ° .
y- Cit te ZiP
E -Mail Address: 3 Q(' "{ / r -T FCH HI4T l •'k ax Number: 31 ti' , & a
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name:
Mailing Address:
State
Zip
City
Contact Person: I \J / 1 t Day Telephone:
E -Mail Address: ` Fax Number:
Contractor Registration Number: Expiration Date:
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
State
Zip
City
Day Telephone:
Fax Number:
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
State
Zip
Day Telephone:
Fax Number.
Page 1 of 6
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15-30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30-50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
f
I
Incinerator - Comm/Ind
MECHANICAL PERMIT INr — 206- 431 -3670
MECHANICAL CONTRACTOR INFORM ATION
Company Name: T 1 Tt c 14T& • W e.
/
Mailing Address: (G+ u d IJ �. 13Th P VF
Contact Person: 1 n m ! 4 0 1 / 1 f)JT- r
E -Mail Address :S4t'I1'� - i ®�'hi TCt/t f>Fi�Tr in
Contractor Registration Number. Tt / A 95�1L
Valuation of Mechanical work (contractor's bid price): $ t i ZJ 00. 00
Scope of Work (please provide detailed information): ckR t ACS
R o 4 -To? uysa-
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... ❑ Replacement ....
Fuel Type: Electric ❑ Gas....(( Other:
Indicate type of mechanical work being installed and the quantity below:
Q: \Application. \Farr. - Application. On uec'3 -2006 - r«arit AppIieation.mo
Rcvinod: 9-2006
bh
Vp>vcouvor wig-. c1431 ,
City State t.� zip
Day Telephone: 3 ' 1 � i / 2 0 t L Q
Fax Number( ) &O / t -,o J
Expiration Date: Co — 1 3-
'-I '7'vt )
Page 4 of 6
Date Application Accepted:
�_ 1 —C17
Date Application Expires:
j l _
07
Staff Initials:
1). I
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUT) � GE
Signature: AMk-
Print Name:
Mailing Address: (03--
Q:1ApplieationsWorms- Applications On Line3 -2006 - Permit Application.doe
Revised: 9 -2006
bh
f - rt
Date: 6 -/-0
Day Telephone: 3(,o C / 0 7 — " 7`-/i 3
Uay.) ,t.Ar- (Arm x (02_
City State Zip
Page 6 of 6
Receipt No.: R07 -00999
Payee: TRI -TECH HEATING
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
PLAN CHECK - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 3523049095 Permit Number: M07 -122
Address: 6750 S 180 ST TUKW Status: PENDING
Suite No: Applied Date: 06/01/2007
Applicant: BASCO Issue Date:
Initials: WER Payment Date: 06/01/2007 01:20 PM
User ID: 1655 Balance: $0.00
TRANSACTION LIST:
Type Method Description Amount
Payment Check 5492 292.63
Account Code Current Pmts
000/322.100 240.10
000/345.830 52.53
Total: $292.63
Payment Amount: $292.63
8828 06/01 9716 TOTAL 292.63
doc: Receipt -06 Printed: 06 -01 -2007
g TBAII/E
Prepared For: Date: May 09, 2007
Tri-Tech Heating
Trane is pleased to provide the enclosed submittal for your review and approval.
Product Summary
Qty Product
1 1.5 -5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A
Matt O'Banion
Trane
7257 SW Kable Lane
Portland, OR 97224 -7181
Phone: (503) 620 -8031
Fax: (503) 639 -1454
niscor
Submittal
Job Name:
Tn -Tech Heating - Basco Wholesale
The attached information describes the equipment we propose to
furnish for this project and is submitted for your approval.
HO7 122
Trane
A Division of American Standard Inc.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN - 5 2107
C
BUIL
Of Tukwila
ING DIVISION
RECEIVED
JUN -1 2007
PERMIT CENTER
Table Of Contents
• Product Summary 1
1.5-5 ton Pkgd. Gas /Elec. Rooftop Convert. R-410A (Item Al)
Tag Data 3
Product Data 3
Mechanical Specifications 4
Unit Dimensions 6
Weight, Clearance & Rigging Diagram 8
Accessory 9
Field Wiring 10
Field Installed Options - Part/Order Number Summary
1.5-5 ton Pkgd. Gas /Elec. Rooftop Convert. R-410A 11
Tags)
Qty
Description
Model Number
( Item
Al RTU -1
1
1.5-5 ton Pkgd. Gas/Elec. Rooftop Conver
4YCC3048 -4096
Tag Data -1.5 -5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A (Qty: 1)
Product Data -1.6 -5 ton Pkgd. Gas /Elec. Rooftop Convert. R-41
Item: Al Qty: 1
Standard ship cyde
Gas Electric, R-410A Refrigerant 13 SEER
4 Tons
460/3/60
96,000 Btuh
1 -2" Filter frame (Fid)
0 -100% Mod. economizer w/bar. relief (Fid)
Crankcase heater (Fld)
Adapter Curb to Existing Trane YCCO36F (Fld)
Rooftop Unit Notes:
1) Less (or by others): Installation, start-up, seismic calculations/restraints, spring vibration isolation, spares,
wire/wiring, thermostats, controls/controls wiring, disconnects, over current protection, smoke detectors, CO2 control,
interface to fire/lights/safety, owner training, installation of field accessories (Fld), and labor warranty.
Mechanical Specifications -1.5 -5 ton Pkgd. Gas /Elec. Rooftop Convert. R- 410A,R -22
item: Al Qty: 1
General
All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be
designed to operate at outdoor ambient temperatures as high as 115 °F . Cooling capacities shall be rated in
accordance with A.R.I standards. The YC heating /cooling unit design is UL listed, specifically for outdoor applications
using natural gas or propane. All units shall be designed for outdoor rooftop or ground level Installation. Unit casing
is constructed of heavy gauge, galvanized steel and painted with a weather - resistant powder paint.
Casings
All panels shall be heavy gauge steel, gasketed and insulated. Foil -faced fiber insulation shall be in the heat
exchanger section. Foil -faced insulation shall be in the evaporator section. Base pan shall be heavy gauge steel.
Weatherguard? exterior corrosion resistant screws shall be used for added resistance to rust and corrosion.
Controls
Refrigeration cycle controls shall include condenser fan, evaporator fan and compressor contactors. Compressors
shall be equipped with a combination internal winding thermostat/current overload. Internal high pressure relief shall
also be provided.
Compressors
The Climatufl) compressor features internal over temperature and pressure protector, total dipped hermetic motor.
Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low
vibration and noise.
Evaporator Coil
Internally enhanced 3/8 -inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and
leak tested at 250 to 300 psig. All units have TXV to control refrigeration flow.
Condenser Coil
The Spine Fin? condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed
joints. This coil is 3/8 inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested
to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient
heat transfer. The coil is protected on all four sides by louvered panels.
Indoor Air Fan
Direct- drive, forward- curved, centrifugal wheel In a Composite Vortica® Blower housing. Motor shall have thermal
overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber
mounts.
Condenser Fan
Direct - drive, draw thru propeller type. Weather - proofed permanent split capacitor fan motor shall have built - in thermal
overload and permanently lubricated motor bearings.
Low Ambient
Standard refrigerant system operation down to 55 °F. Low ambient accessory required for operation to 0 °F ambient
condition.
Gas -Fired Heating Section
Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified
by UL, specifically for outdoor application. Threaded gas connection on the unit.
Electronic Ignition System
Main burner is lit each time thermostat calls for heat. Flame sensor proves flame and keeps the main burners on.
Should a loss of flame occur, the main valve doses and the spark recurs within 0.8 second. When thermostat is
satisfied, main burner is extinguished.
Forced Combusion Blower
Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility.
Heat Exchanger
Stainless steel tubes. Free floating design.
Burners
Stainless steel. Multi-port inshot.
Modulating Economizer
This accessory shall be field installed and be composed of the following items: 0- 100% fresh air damper, damper
drive motor foced dry bulb enthalpy control, and low voltage polarized plug for electrical connections. Solid state
enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position
of the enthalpy control. A barometric relief damper shall be standard with the economizer and provide a pressure
operated damper that shall be gravity dosing and prohibit entrance of outside air on equipment "off" cycle.
Unit Dimensions -1.5.5 ton Pkgd. Gas /Elec. Rooftop Convert. R- 410A,R -22
Item: Al Qty: 1
11/16" I I 11/16"
SECTION Y -Y
TYPICAL (8) SIDES OF
DOWNFLOW DUCT OPENINGS
24V ENT
7"
3 stir—
UNIT -TOP VIEW
9/18" 14 11/16"
AIR FLOW
r
UNIT - RIGHT SIDE VIEW
SUPPLY
RETURN �+
X X
6
2 1/4"
35/18" 1711/1
WER ENTRY 25.40 [1 } DIA. HOLE
3 7/8" AS LINE ENTRY FOR 12.70 [1/2} N.P.T.
GAS CONNECTION
AIR FLOW
I
17 11/1
UNIT - BACK AND PENETRATION VIEW
"TOP VIEW LOOKING DOWN
12 7/8"
HORIZONTAL
AIR FLOW
1
1"
UNIT - BOTTOM PENETRATION VIEW
20 7/8"
SECTION X -X
TYPICAL (8) SIDES OF
SIDEFLOW DUCT OPENINGS
¢-21 11/16"-.I ` CONDENSATE DRAIN FOR
UNIT - LEFT SIDE VIEW
19.0 [3/4[ FEMALE NPT
9/18"
POWER CONNECTION
Model: 4YCC3048A4088
Voltage Range: 480/3/80
Min. Circuit Ampacity: 11.7
Max. Circuit Breaker. 15.0
Prot R. Recmd: 15.0
ERR/SEER 11.0/13.0
Noise Rating # : 80.0
COMPRESSOR
Number.
Phase:
Rated Load Amps:
Locked Rotor Amps:
1
3
7.05
48.0
GAS HEAT Type of Gas: NATURAL
Capacity BTUH: 98000
Temp. Rise F (Min./Mb): 3060
Gas Size Pipe:
OUTDOOR MOTOR
Number.
Horsepower.
Phase
Full Load Amps:
Locked Rotor Amps:
1
0.25
1
0.74
1.6
REFRIGERANT
Type T1-410
Factory rge 8.2 lb
INDOOR MOTOR
Number.
Horsepower.
Motor Speed (RPM):
Phase
Full Load Amps:
Locked Rotor Amps:
0.75
1080
2.2
4.38
Unit Dimensions -1.5-5 ton Pkgd. Gas/Elec. Rooftop Convert. R- 410A,R -22
Item: Al Qty: 1
ELECTRICAL / GENERAL DATA
NOTES:
1. Capacity rated in accordance with AR.I. Standard 210240. Noise rated in accordance with ARI. standard 270. ARI. standard rating conditions are:
80 D.B. 87 W.B. entering air to indoor coil 9513.B. entering air to outdoor coil.
2. All models are U.L fisted. Ratings shown are for elevations w to 2000 feet For higher elevations reduce ratings at the rate of 4 percent per 1000 feet elevation.
3. Based on U. S. Government Standard Tests.
4. Unit ships on high input and is convertible to low input with a low fire accessory kit.
5. Convertible to LPG with orifice change.
UNIT WEIGHT
CORNER WEIGHT
CENTER OF GRAVITY
SHIPPING
NET
W1
W2
W3
W4
WS
W8
A
B
1553.0112
525.0 b
278.0 b
249.0 b
111.0112
'188.0Ib
149.0 b
V0.0112
771/2"
28 5/18"
CLEARANCE TO COMBUSTIBLE MATERIAL
RECOMMENDED SERVICE CLEARANCE
BOTTOM
0
UNIT
WITH O.A. DAMPER/ECON.
WITH 2 POS. DAMPER
BACK SIDE
1"
BACK SIDE
12"
24"
LEFT SIDE
6"
LEFT SIDE
38"
42"
RIGHT SIDE
8"
RIGHT SIDE
42"
FRONT SIDE
12"
FRONT SIDE
47'
TOP
38"
Weight, Clearance & Rigging Diagram -1.5 -5 ton Pkgd. Gas /Elec. Rooftop Convert. R- 410A,R -22
Item: Al Qty:1
wil
W4
W2
W5
FLUE HOOD
CENTER OF GRAVITY
Accessory -1.5 -5 ton Pkgd. Gas /Elec. Rooftop Convert. R -410A,R -22
Item: Al Qty: I
ECONOMIZER
RAIN HOOD
24 318"
DOWN FLOW ECONOMIZER RAIN HOOD
WIRE COLOR CFSGNATION
ABER
COLOR
INN
COLOR
BR
BLACK
PR
PURPLE
SL
BLUE
RD
RED
Ht
MOWN
M/
MITE
GR
GREEN
YL
YELLOW
OR
GRANGE
Field Wiring -1.5 -5 ton Pkgd. Gas/Elec. Rooftop Convert. R- 410A,R -22
Item: Al Qty: 1
III I r r _ _ _� 4 : )Y
I I I r 1 — � NC(Npw:
I III I r _ _ - - — p ` JL WA R
III I II II r
• I 111 I I I
• I PH ▪ I
RAW
! TYPICAL 2 STAGE
Y IEATTiF7MAOSTAT
POWER
UNIT
NOTE 1
00
PACKAGED GAS-ELECTRIC UNIT
UNIT CONTROL BOX
TWO STAGE FEAT
TERMOSTATCOIIECRONS
{
UNIT LOW VOLTAGE AREA
NOTES:
TYPICAL 1 STAGE
EAT T1WOSTAT
NOTE6
SNGLE STAGE
THERMOSTAT CONNECTIONS
26(BL) 8
pA9V
NA(YL Y
N Aq WI
4 1C(BRj W2
N6A(RD) R
ITLOW
VOLTAGE AREA
CO68LON
FAN
OPPRESSOR
IEATFIRST STAGE
TEAT SECOND STAGE
2WV
LATER .COMPONTENT WIRNEI
NV. FACTORY
LINE V. WIRING
- 24V. FIELD
LINE V. WIRING
FAN
CO6PNESSOR
HEAT FRET STACIE
FEAT SECOND STAGE
24V
1. FUSED DISCONNECT SIZE, POWER WIRING AND GROUNDING
OF EQUIPMENT MUST COMPLYNRIH CODES.
S BE SURE POWER SUPPLY AGREES WITH EQUIPMENT AND
HEATER NAMEPLATE.
3. LOW VOLTAGE WIRING TO BE 18 AWO MINIMUM CONEUCTOR.
4. SEE UNIT D AGRAM POR ELECTRICAL CONNECTION DETAILS.
S THE THERMOSTAT ON THE GASIELECTRIC UNIT MUST PROVIDE
A 4 SIGNAL N THE COOLING MODE ONLY. DURING THE
HEATING MODE THE FAN WILL BE ENERGIZED BY THE SYSTEM.
Q FOR SINGLE STAGE THERMOSTATS JUMPER W1 AND W2 TOGETHER.
SECOND STAGE HEAT WILL BEGIN 10 MINUTES AFTER FIRST
STAGE
ECONOMIZER ACCESSORY
TOECONQRER CONNECTIONS
FACTOR'PROVIED
FELD NSULLED
WIRES
LNT
VOLTAGE AREA
26 E1 01 4 R 26B(BL)13
r «
I 1410
MM
TYPICAL 2STAGE
TERMOSTAT
REID
INSTALLED
JUMPER
4TAGINO
44A(YL) Y
Q 41A(Bf5W1
I I I r r - 41cG)wW2
I I
r- SL _ ACRD) R
Field Installed Option Description
Part/Ordering Number
1 -2" Filter frame
BAYFLTR201A
Crankcase heater
BAYCCHT404B
, 0 -100% Mod. economizer w/bar. relief
BAYECON102A
Item
Tag(s)
Qty
Description
Model Number
Al
No Tag
1
1.5-5 ton Pkgd. Gas/Elec. Rooftop Conver
4YCC3048 -4096
Field Installed Options - Part/Order Number Summary
This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or
order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a
bill of material for the job.
Product Family -1.5 -5 ton Pkgd. Gas/Elec. Rooftop Convert. R- 410A,R -22
From .11
To
Co.
+f
Co. /Dept - !} ' ��
. . „ J_ ,t �-
Phon #
(503)
620 -$031
Phone #
Fax #
(503)
639 -1454
Fm # 3 to b - s c U . I c1 / d
YCCO35F3MOB
2135-230/3/60
YCCO35F3H0B
208- Z30/3/60
Y00036FWHDB
575/3/00
?,IDBEL
RATER VOLTS Z
A.R.I. RATINGS (COOUNG)D
BTOH
Indoor Air Flow (CFM)
System Power (KW)
EER/SEER (RTU/WAfT -HR.)
Noise Rating No.
A.G.A. HATINGs (HEATING)GP
(High) Input BTUII
Capacity Bil)H ®u
ARE
Temp. Rise "F (M n./Mu)
(Low) Inappuai FUR
AFUE /CSE
Temp. Rise 'F (Min./Max.)
Type of Gas3:
PUWER CONNS. - V/PH/HZ
Min. Brdi. Ct. Ampocity
Br. Cir. - Max. (Amps)
Prot. Rtq. - Rocmd. (Amps)
COMPRESSOR
Na Used
Vofts/PH/HZZ
RI Amps - L.R. Am I s
OUTDOOR COIL TYPE
Rays / F.P.I.
Fare Area tSo. Ft.)
Tube See (in.)
INDOOR COIL - TYPE
Rows / F.P_I.
Fare Area (Sq. Ft)
Tuba Fin (in.)
Refrigerant Control
Dram Corm. SSte (h)
Duct Camec lout
OUTDOOR FAN - TYPE
No. Used / as 6n.)
Type Drive / No- Speed,
Na. Mat= - HP
Motor Speed R.P.M.
Vohs/12 - Amps - LR. Amps
INDOOR MN - TYPE
pia x Width (
Na. Used
Drive / Speeds (No -)
No. Motors - RP
Meta Speed R.P.M.
Vans /HZ
F.L Anus - LR. Amps
COMBUSTION FAN - TYPE
Drive - Speeds (N0.)
Motor HP --- Speed (RPM)
Valts/PH/HZ
F.L Amps
FILTER - FURNISHED?
Type Retrnmendod
Min. Face Area-Lo (tt)3:
REFRIGERANT
Charge (Ibs. of R•22)W
GAS PIPE SIZE (IN.)
OIMENS1ONS
elated L1 ed )
10
35400
1200
3.73
9.50 / 10.00
8.0
48000
7 380
30/65
32 0
78 %/76%
NATURAL
208- 230/3/60
18
25
25
C IMATUFr
1
200 230/3/60
11 - 101
PLATE FIN
2/20
8.34
3/8 COPPER
PLATE FIN
3/15
3.96
3/8 COPPER
3/4" FEMALE NKr
SEE OUTLINE ORPIJSNG
PROPELLER
1/18
DIRECT / 1
1 -1/5
1080
230/1/60
1.6 - 3.3
CENTRIFUGAL
30 X 9
DIRECT /
1--1/3
1080
200- 220/1/80
2.8/22 -- 5.1
CENTRIFUGAL
DIRECT -1
- 3480
240/
0.6
NO
THRONITWAY
4.0
5.7 lbs.
1/2"
HXWX0
35 -1 /4X 3$ X 57
SEE OUTLINE DRAINING
General
Data
35400
1200
3.73
9.50 / 10,00
5.0
100000
80000
45/75
tem
78 %/70%
45 -75
NATURAL
208- 2311/3/60
18
25
25
CUMATUFF"
1
200- 230/3/60
11 -101
PLATE FIN
2/20
6.34
3/8
PLATE FIN
3/15
3.96
CAPILLARY
3/4" FEMALE
SEE OUTLINE DRAWING
PROPELLER
1/18
DIRECT/1
1 -1/5
1080
230/1/60
1.6 - 3.3
CENTRIFUGAL
101 9
DIRECT / 2
1 »3
200 - 230/1/80
2.8/2.2 - 5.1
CENTRIFUGAL
DIRECT -1
1/35 - 3480
208 - 240/1/60
0.6
NO
THROWAWAY
4.0
5 lbs. 15 ca.
1/2"
HXWXD
351/4 X 38 X 64.5/8
SEE OUTLINE DRAINING
35400
1200
3.73
9.50 / 10.00
8.0
100000
80000
78%
45/75
80000
84000
78%176%
NATURAL
460/3/60 /
15
15
CUMATUFF"
1
460/3/60
4 - 51.0
PLATE RN
2/20
3/8
PLATE RN
3/15
3.96
3/8
3/4" FEMALE
SEE OUTLINE DRAWING
PROPELLER
1/18
DIRECT / 1
1 1080
480/1/50
1.7 -3.8
cENTRSFUGAL
10X9
DIRECT / 2
1 - 1/3
460/1/60
1.1- 2.8
CENTRIFUGAL
DIRECT -1
1/35 - 3480
208- 240/1/60
0.6
NO
THROWO AY
5 Or. 15 co_
I/2"
HXWXD
35- 1/4X38 X64-5/8
SEE 011111EIE BRINING
35400
1200
3.73
9.50 /10 -00
8.0
1110300
7 8�
45/75
80000
640(10
78 %/76%
45 -75
NATURAL
575/3/60
6.4
10
10
CLIMATUWF"
1
575/3/60
3.3 -41
PLATE FIN
2/20
6.34
3/8
PLATE FIN
3/15
3.95
3/8
3/4" FEMALE
SEE OUTLINE DRANIN6
PROPELLER
1
DIRECT / 1
1 1080
575/1 /60
1.4 - 3.2
ce mfUSAL
10 X 9
DIRECT /
1 -1/3
57
.9 - 2.0
CENTRIFUGAL
DIRECT - 1
1/35 - 3480
208 -240/1 /60
0.5
NO
THROWAWAY
5 lbs. 15 oz.
1/2
HXwxD
35-1 /4 X 38 X 646/8
SEE OUTLINE DMP)MNG
WEIGHT
- --�r
811141w Ohs.) / NEL Ohs.)
See notes on page 14
426 / 386
452/403
440 / 394
i
t
0
7777 - 4 -- 1/
•
.} /
' #ol f
I pales F r
76 9 1 _ I_
•
Co. TRAN
Co./Dept 44 . 4 ..
k " t " ` - OI
Phone #
(503) 620.6031
Ph #
Fax #
(503) 639 -1454
Fa " # 3(00 - S 91 . 19/4
MOQE
RATED VOLTS/PH/HZ
IL t RATINGS (COG )o
UNG
Indoor Air Haw (CFM)
em Power ()OM SEER
No a RRaty No HR)
A.GA . RATINGS (HEA PJCW
RIM Nut BTU(
Capacity BT{JH23st
AWE
Temp. Rise "F (Min. /Max.)
(I orv) Input FUR
A�CSE/
Temp. Rise "F 4Min./Ma .)
Type of Gast
POWER CORNS. - V/PH/HZ
.n. Rick r.
B A s
Br. (�. -M Max ( )
Prot. Rtg. -- Rearm (Amps)
COMPRESSOR
No. Used
Wits/PH/HZ
RI Amps -- L.R. Amps
OUTDOOR COIL - TYPE
Rows / F.P.I.
Face Area (Sq. Ft.)
Tube Sae (in.l
INDOOR COIL - TYPE
Rows /
Face Moo (Sq. Ft)
Tube Size (in-1
Refrigerant Control
Drain Cam. Sus (in.)
Data Connections
OUTDOOR FAN - TYPE
No. Used / Diia Cm.)
Type Drive / No. Speeds
No. Motors - HP
Motor Speed R.P.M.
Volts/PH /HZ
FL Am - LE_ Amps
INDOOR FAN - TYPE
Ora x Width Lin_)
Na Used
Drive / Speeds (No.)
Na. Motors - HP
Motor Speed R.P.M.
Volts/PH /HZ
FL Amps - LR. Amps
COMBUSTION FAN - TYPE
Drive - Spuds (NA.)
Motor HP - Speed (PPM)
Volts/PH/HZ
FL Amps
FILTER - FURNISHED?
Type Recommended
M'm_ Face Are. -Lo lft.)i
REFRIGERANT
Charge (lbs. of R-22)€
GAS PIPE SIZE (IN.)
DIMENSIONS
U ad (in.)
WEIGHT
Shi (lbs.) / Net (Ibs.)
Sea notes on page 14
10
YCCO36E3MOB
208 -230/ 3/60
35400
3�
9.50 / 10.00
8.0
48000
7 380000
30/65
40000
32000
78%/75%
30 - 65
NATURAL
208- 230/3/60
18
25
25
CUMATUFF"'
1
200 - 230/3/80
11 - 101
PLATE FIN
2/20
6.34
3/9 COPPER
PLATE FIN
3/15
3.98
3/8 P COPPER
3/4" FEMALE NPT
SEE OUTLINE ORN/ING
PROPELLER
1/18
DIRECT / 1
1 -1/5
1080
230/1/60
1.6 - 3.3
CENTRIFUGAL
10X9
1
DIRECT /
1--
1080
200 - 230/1/60
2.8/22 - 5.1
CENTRIFUGAL
DIRECT .-1
240//
0.6
NO
THRI INNAY
4.0
HXWXD
35 1/4X
SEE OUTLINE DRA5rvirep
426 / 385
General
Data
YCC.I35F31100
206. 230/3/60
35400
1200
9.50 / 10.00
8.0
100000
80000
46/75
80000
7
45 -75
NATURAL
208 - 230/3/60
18
25
25
CUMATIIFF
1
200- 230/3/60
11 -101
PLATE FIN
2/
36
PLATE FIN
3/15
396
CAPILLARY
3/4" FEMALE
SEE OUTLINE CRANING
PROPELLER
1 DIRECT / 1
1 -1/5
1080
230/1/60
1.6 - 3.3
CENTRIFUGAL
10 X 9
1
DIRECT / 2
1 - 1/3
200 - 2
2.8/23 -5.1
CENTRIFUGAL
DIRECT -1
1/35 - 3480
208- 240/1/60
0.6
NO
THROWAWAY
4.0
HXWXD
35 X 38 X 64
SEE OUTLINE CRANING
452 / 403'
35400
12013
3.73
9.50 / 10.00
8.0
100000
80000
78%
45 / 75
80000
64000
701/78%
45 -75
NATURAL
480/8/60
15
8
15
CUMATUFF'
1
460/3/60
4 --51.0
PLATE FIN
8�
3/8
PLATE FIN
3/8
CAPILLARY
3/4" FEMALE
SEE OUTUNE DRONING
PROPELLER
1/18
DIRECT / 1
1 1080
400/1/60
1.7 - 3.8
CENTRIFUGAL
10X9
1
DIRECT / 2
1 1080
480/1/60
1.1- 2.6
CENTRIFUGAL
DIRECT - 1
1/35 - 3480
2011-2413/1/60
0.6
NO
THROWAWAY
4.0
5tbs_15
1/2"
HXWXD
35-1/4 X 38 X 54-5/8
SEE OUTLINE DRONING
440 / 394
YCCO35FWIIOR
575/3/60
35400
1200
3.73
9_50 /101X1
8.0
100000
80000
45/75
80000
78
45 -75
NATURAL
575/3/60
6.4
10
10
575/3/60
3.3 -41
PLATE FIN
2/20
3
PLATE FIN
3 /15
3/8
CAPILLARil
3/4" FEMALE
SEE OUTLINE DRAWING
PROPELLDI
DIRECT / 1
1 1080
575/1 /60
1.4 - 3.2
CEN)RJFU&AL
10 X 9
1
DIRECT /
1--1/3
Ia
575/
.9 ---2.0
CENTRIFUGAL
DIRECT -1
1/35 - 3480
208-240/1/60
NO
THROWAWAY
4
5 Ibs.15 ar.
HXWXD
35.1/4X38X64-5/8 •
S� 1)1/fiNE DROMNG
440 394
11 -06 -2007
TIM HOLLIPETER
6603 N E 137 AV
VANCOUVER WA 98682
RE: Permit No. M07 -122
6750 S 180 ST TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in writinf and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 12/05/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
II
xc:
fer Marshall,
t Technician
Permit File No. M07 -122
City of Tukwila
Steven M. Mullet, Mayo
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
ACTIVITY NUMBER: M07 -122 DATE: 06 -01 -07
PROJECT NAME: BASCO
SITE ADDRESS: 6750 S 180 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
DEPARTMENT % Buil ng Division
Public Works El
Complete
Documents /routing slip.doc
2 -28-02
PLAN REVIEW /ROUTING SLIP
Fir e Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete
Planning Division
n
❑ Permit Coordinator ❑
DUE DATE: 06-05 -07
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTI G:
Please Route Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 07-03 -07
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#1
WESTERN
SURETY
CO
14714206
06/10/2005
Until
Cancelled
$6,000.00
06/13/2005
Business Owner Information
Name
Role
Effective Date
Expiration Date
HARMON, BRENDA
06 /13/2005
HARMON, JEREMY
PRESIDENT
06 /13/2005
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
Licensee Name
Licensee Type
UBI
Ind. Ins. Account Id
Business Type
Address 1
Address 2
City
County
State
Zip
Phone
Status
Specialty 1
Specialty 2
Effective Date
Expiration Date
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
TRITEHI952LL
TRI -TECH HEATING INC
CONSTRUCTION CONTRACTOR
602255131
87916201
CORPORATION
6603 NE 137TH AVE
VANCOUVER
CLARK
WA
98682
3608912002
ACTIVE
AIR CONDITIONING
UNUSED
6/13/2005
6/13/2009
TRITEH *077NF
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= TRITEHI952LL 06/08/2007
C
05
C
1
C
• CS
Go z
Q
•
TANK 7'
FILL W!
ROCK
NORTH LINE OF GOVERNMENT LOT 1
FENCE CORNER IS 1.4' SOUTH
OF THE PROPERTY UNE.
PAVEMENT CORNER IS 0.6' SOUTH
OF THE PROPERTY LINE.'
- � N8744'08 "W 949.49'_ --__
SHAST
ac
FENCE CORNER IS 0.8' SOUTH
.OF THE PROPERTY UNE.
S 8808'21 "E
'C' s CCMPACT (8'46' INCL. 2' MONO)
S' WIDE GAS PIPEUNE
EASMENT TO WASHINGTON
NATURAL GAS COMPANY
FOR GAS PIPEUNE
REC. NO. 9503300236.
300.00'
FIRST FLOOR TOTAL:
OFFICE ( )
Wd HOUSE (SU
PRODUCTION a5)
$140P (F)
flgagara
6ECCND FLOOR TOTAL:
51•Ic1I ROCh1(A -3)
OFFICE (8)
S° Y∎PA s (8)
— PARKING IN THIS AREA
BY EMPLOYEES OF
SHASTA BEVERAGES
46,168 SP.
8311 SF.
16302 SP
18351 SF.
2388 SE
4318 SF.
1358 SF
1.010 SF.
1,650 SP
PARKNG RECURRED:
CFFK 4CT. /1000 * 10 * 26 CARS
WAREHOUSE / I U1000. 39,412 ■ 39.4 CARS
65 CARS
PARKING 5 N: 68 NCLUDNG (3 14C, i3 COMPACT, 46 STANDARD)
EDGE OF PAVEMENT IS
SOUTH OF THE PROPER
6' CHAINLINK FENCE
FENCE IS 1.0'
WEST OF THE
PROPERTY UNE
EAVE IS 0.7' WEST ' ,OF
THE PROPERTY LINID:
4
NEW TMES
1 -STORY CONCRETE BUILDING
1233 ANDOVER ARK EAST
,324 53'
•
V 6° -
pF
vg � \ c
L F
t
HRST FLOOR TOTAL:
OFFICE (B)
(SU
SECOND FLOOR TOTAL:
EXISTING CAR PARKING.
TYPE CONSTRUCTION: IIH -
ZONNG: URBAN CENTER
TAX a 3523 -0490
6'
LINE.
45,662 SF.
4,658 SE
41p04 SF
4,158 5F
65
SPRINKLERDD (1955)
LEGEND
-
I. PROVIDE mu SINGLE PLY PVC ROOFING
SYSTEM OVER EXISTING BUILT-UP ROOF.
2. PROVIDE ALTEMATE PRICE FOR SINGLE PLY
TORGI•IZ701W ROCFNG SYSTE 1 IW COVER
BOAR] OVER EXISTIFIG ROCFddG.
3. PROVIDE ALTERNATE PRICE FOR REMOVAL
4 PROPER DISPOSAL GE USING ROOFING
PRIOR TO RE-ROCFM 1W EITHER PVC CR
TORCIVOUJN ROCFM SYSTEMS.
4. PROVIDE ALL NECESSARY FLAA5HII4SS 4
ASSESSOR ES TO PROVIDE FULL WARRANTY.
5. PROVIDE 20 YEAR RLL MFLACEMENT
WARRANTY FOR ROCMG SYSTEM MULLED.
2 —STORY CONCRETE BUILDING
6750 SOUTH 180TH STREET
TYPICAL. NEW 4' X 8' SI'1OKE VENT SKYLIGHT
FER LFC 81026.14 8102bb SEE MS. I/A -I 4 2/A -I
i 0 t� 01!:
o t9 a 6l -- -- '
0 le
� 6 o r)
ra
D D ■ �'1•.
SEMOvE EXISTNG AS NALT PAVING 4 BASE.
CCP1PAGT 4 RE- NSTALL 4' ROCK BASE.
INSTALL NEW 2' A5F1•IALT PAYING 4 STRIPING.
R.O.S.
REC. NO. 8509249015
VALLEY PROPERTIES
f • FIRE DEPARTMENT CONNECTION
+ POST INDICATOR VALVE
— W —WATER LINE
— G — GAS LINE
TELECOMMUNICATIONS JUNCTION
LIGHT VAULT
POWER VAULT
SIGNAL VAULT
WATER METER
CATCH BASIN
III GAS VALVE
— S — SANITARY SEWER
SANITARY SEWER
UNE
MANHOLE
BOX
1
r7
DEC 0 5 2007
N.E. CORNER
OF GO
.f. LOT 1
I
O7 J22
y t 449.59'
F
-3t1
W
w
0
'°- I
6
25
36
DEEDED MERIDIAN
20 10 '0 20
GRAPHICAL SCALE: 1" = 20'
IEVIEW COMPLIANCE
CODE
APPROVED
JUN - 5 2 07
ty Of Tukwila
BUILDING QJLJON
S 'RATE PBRmir
❑
Mechankal
V E l ectrical
'plumbing
is Piping
City of Tukwila
BUILDING DS
Permit No.
Plan review approval Is subs to emirs and om1
Approval of constru*•on d� does not authorize
the vlolat; ^^ I acep:ed code or ordina r e.
of apprc. �1 Is a Wedged: d
Date:‘
City of Tukwila
BUILDING DIVISION
3
- 63 ' Welkin*
No changes shall ba made to the sop
c v,c:-oc without prior a pproval cif
yr' ' a r. W
LIGHT POLE
RAILROAD SIGNAL POLE
l4 WATER VALVE
WATER VAULT
R FIRE HYDRANT
A POWER METER
® POWER TRANSFORMER
P
▪ HANDICAP PARKING STALL
EDGE OF ASPHALT
CONCRETE SURFACE
FOUND "4X4" CONCRETE
MONUMENT WITH BRASS
TACK IN CASE
RECEWED
JUN -1 2007
PERMIT CEN1 ER
w cco
00 00
I I
re) CD
NI N
CD CD
N N
W
ox
Q L
nn .�nr ,r'- 4' ec-7 ( t kin ev I J�:..A1'