Loading...
HomeMy WebLinkAboutPermit M07-122 - BASCOBASCO 6750 S 180 ST EXPIRED 12 7 M07 -122 Parcel No.: 3523049095 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 6750 S 180 ST TUKW DESCRIPTION OF WORK: REPLACE (1) 4 TON ROOFTOP UNIT Value of Mechanical: $11,800.00 Type of Fire Protection: Cityf Tukwila BASCO 6750S 180 ST , TUHWILA WA AMC FAMILY LLC PO BOX 2720 , PORTLAND OR Contact Person: Name: TIM HOLLIPETER Address: 6603 N E 137 AV , VANCOUVER WA Contractor: Name: TRI -TECH HEATING INC Address: 6603 NE 137Th AVE , VANCOUVER WA Contractor License No: TRITEHI952LL Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMG10 /06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 - 3665 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * *continued on next page ** M07 -122 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360 -907 -7413 Phone: Expiration Date: 06/13/2009 M07 -122 06/08/2007 12/05/2007 Fees Collected: $292.63 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-16 HP /600,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 06-08 -2007 Permit Center Authorized Signature: 7 Signature: doc: IMG10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -122 Issue Date: 06/08/2007 Permit Expires On: 12/05/2007 Date: ri l vU j - I hereby certify that I have read and xanjmed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this pe does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru 'e = ce • ork. I am a _ orized to sign and obtain this mechanical permit. Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende4 or abandoned for a period of 180 days from the last inspection. M07 -122 Printed: 06-08 -2007 Parcel No.: 3523049095 Address: 6750 S 180 ST TUKW Suite No: Tenant: BASCO 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 1u✓ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -122 Status: ISSUED Applied Date: 06/01/2007 Issue Date: 06/08/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. T: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M07 -122 Printed: 06-08 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the perf • rmance of work. Signa Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date &' a D M07 -122 Printed: 06-08 -2007 CITY OF TUKf'A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwatukwila.wa.us Company Namc: Mailing Address: Contact Person: / E -Mail Address: 666 Q:MpptiestionsWonn Application On uno13-2006- Permit Applie tion.doc Revised: 9 -2006 bh Building Permit No. Mechanical Permit No. I" n 07 Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION '(3 , ASe.o Tenant Name: Property Owners Name: (� Mailing Address: !/ SO C t u V Contact Person: E -Mail Address: • —1—U-V vc City City 3,5).301-,1909 - __ { (� . King Co Assessor's Tax No.: // Site Address: l9 75 S . I v0 Suite Number: Floor: New Tenant: ❑ Yes ix,,. (A) . ct 3l 9� S tate Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Tim tk O 1h Day Telephone: 3( go Mailing Address: ID SOD l3 �. U11 v Roe 0000144 wet- 1 € 6,0 ° . y- Cit te ZiP E -Mail Address: 3 Q(' "{ / r -T FCH HI4T l •'k ax Number: 31 ti' , & a GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: State Zip City Contact Person: I \J / 1 t Day Telephone: E -Mail Address: ` Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: State Zip City Day Telephone: Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record State Zip Day Telephone: Fax Number. Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15-30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM f I Incinerator - Comm/Ind MECHANICAL PERMIT INr — 206- 431 -3670 MECHANICAL CONTRACTOR INFORM ATION Company Name: T 1 Tt c 14T& • W e. / Mailing Address: (G+ u d IJ �. 13Th P VF Contact Person: 1 n m ! 4 0 1 / 1 f)JT- r E -Mail Address :S4t'I1'� - i ®�'hi TCt/t f>Fi�Tr in Contractor Registration Number. Tt / A 95�1L Valuation of Mechanical work (contractor's bid price): $ t i ZJ 00. 00 Scope of Work (please provide detailed information): ckR t ACS R o 4 -To? uysa- Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... Fuel Type: Electric ❑ Gas....(( Other: Indicate type of mechanical work being installed and the quantity below: Q: \Application. \Farr. - Application. On uec'3 -2006 - r«arit AppIieation.mo Rcvinod: 9-2006 bh Vp>vcouvor wig-. c1431 , City State t.� zip Day Telephone: 3 ' 1 � i / 2 0 t L Q Fax Number( ) &O / t -,o J Expiration Date: Co — 1 3- '-I '7'vt ) Page 4 of 6 Date Application Accepted: �_ 1 —C17 Date Application Expires: j l _ 07 Staff Initials: 1). I Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT) � GE Signature: AMk- Print Name: Mailing Address: (03-- Q:1ApplieationsWorms- Applications On Line3 -2006 - Permit Application.doe Revised: 9 -2006 bh f - rt Date: 6 -/-0 Day Telephone: 3(,o C / 0 7 — " 7`-/i 3 Uay.) ,t.Ar- (Arm x (02_ City State Zip Page 6 of 6 Receipt No.: R07 -00999 Payee: TRI -TECH HEATING ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049095 Permit Number: M07 -122 Address: 6750 S 180 ST TUKW Status: PENDING Suite No: Applied Date: 06/01/2007 Applicant: BASCO Issue Date: Initials: WER Payment Date: 06/01/2007 01:20 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 5492 292.63 Account Code Current Pmts 000/322.100 240.10 000/345.830 52.53 Total: $292.63 Payment Amount: $292.63 8828 06/01 9716 TOTAL 292.63 doc: Receipt -06 Printed: 06 -01 -2007 g TBAII/E Prepared For: Date: May 09, 2007 Tri-Tech Heating Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 1.5 -5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A Matt O'Banion Trane 7257 SW Kable Lane Portland, OR 97224 -7181 Phone: (503) 620 -8031 Fax: (503) 639 -1454 niscor Submittal Job Name: Tn -Tech Heating - Basco Wholesale The attached information describes the equipment we propose to furnish for this project and is submitted for your approval. HO7 122 Trane A Division of American Standard Inc. REVIEWED FOR CODE COMPLIANCE APPROVED JUN - 5 2107 C BUIL Of Tukwila ING DIVISION RECEIVED JUN -1 2007 PERMIT CENTER Table Of Contents • Product Summary 1 1.5-5 ton Pkgd. Gas /Elec. Rooftop Convert. R-410A (Item Al) Tag Data 3 Product Data 3 Mechanical Specifications 4 Unit Dimensions 6 Weight, Clearance & Rigging Diagram 8 Accessory 9 Field Wiring 10 Field Installed Options - Part/Order Number Summary 1.5-5 ton Pkgd. Gas /Elec. Rooftop Convert. R-410A 11 Tags) Qty Description Model Number ( Item Al RTU -1 1 1.5-5 ton Pkgd. Gas/Elec. Rooftop Conver 4YCC3048 -4096 Tag Data -1.5 -5 ton Pkgd. Gas/Elec. Rooftop Convert. R-410A (Qty: 1) Product Data -1.6 -5 ton Pkgd. Gas /Elec. Rooftop Convert. R-41 Item: Al Qty: 1 Standard ship cyde Gas Electric, R-410A Refrigerant 13 SEER 4 Tons 460/3/60 96,000 Btuh 1 -2" Filter frame (Fid) 0 -100% Mod. economizer w/bar. relief (Fid) Crankcase heater (Fld) Adapter Curb to Existing Trane YCCO36F (Fld) Rooftop Unit Notes: 1) Less (or by others): Installation, start-up, seismic calculations/restraints, spring vibration isolation, spares, wire/wiring, thermostats, controls/controls wiring, disconnects, over current protection, smoke detectors, CO2 control, interface to fire/lights/safety, owner training, installation of field accessories (Fld), and labor warranty. Mechanical Specifications -1.5 -5 ton Pkgd. Gas /Elec. Rooftop Convert. R- 410A,R -22 item: Al Qty: 1 General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 115 °F . Cooling capacities shall be rated in accordance with A.R.I standards. The YC heating /cooling unit design is UL listed, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level Installation. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather - resistant powder paint. Casings All panels shall be heavy gauge steel, gasketed and insulated. Foil -faced fiber insulation shall be in the heat exchanger section. Foil -faced insulation shall be in the evaporator section. Base pan shall be heavy gauge steel. Weatherguard? exterior corrosion resistant screws shall be used for added resistance to rust and corrosion. Controls Refrigeration cycle controls shall include condenser fan, evaporator fan and compressor contactors. Compressors shall be equipped with a combination internal winding thermostat/current overload. Internal high pressure relief shall also be provided. Compressors The Climatufl) compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. Evaporator Coil Internally enhanced 3/8 -inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig. All units have TXV to control refrigeration flow. Condenser Coil The Spine Fin? condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Direct- drive, forward- curved, centrifugal wheel In a Composite Vortica® Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan Direct - drive, draw thru propeller type. Weather - proofed permanent split capacitor fan motor shall have built - in thermal overload and permanently lubricated motor bearings. Low Ambient Standard refrigerant system operation down to 55 °F. Low ambient accessory required for operation to 0 °F ambient condition. Gas -Fired Heating Section Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electronic Ignition System Main burner is lit each time thermostat calls for heat. Flame sensor proves flame and keeps the main burners on. Should a loss of flame occur, the main valve doses and the spark recurs within 0.8 second. When thermostat is satisfied, main burner is extinguished. Forced Combusion Blower Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger Stainless steel tubes. Free floating design. Burners Stainless steel. Multi-port inshot. Modulating Economizer This accessory shall be field installed and be composed of the following items: 0- 100% fresh air damper, damper drive motor foced dry bulb enthalpy control, and low voltage polarized plug for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometric relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity dosing and prohibit entrance of outside air on equipment "off" cycle. Unit Dimensions -1.5.5 ton Pkgd. Gas /Elec. Rooftop Convert. R- 410A,R -22 Item: Al Qty: 1 11/16" I I 11/16" SECTION Y -Y TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS 24V ENT 7" 3 stir— UNIT -TOP VIEW 9/18" 14 11/16" AIR FLOW r UNIT - RIGHT SIDE VIEW SUPPLY RETURN �+ X X 6 2 1/4" 35/18" 1711/1 WER ENTRY 25.40 [1 } DIA. HOLE 3 7/8" AS LINE ENTRY FOR 12.70 [1/2} N.P.T. GAS CONNECTION AIR FLOW I 17 11/1 UNIT - BACK AND PENETRATION VIEW "TOP VIEW LOOKING DOWN 12 7/8" HORIZONTAL AIR FLOW 1 1" UNIT - BOTTOM PENETRATION VIEW 20 7/8" SECTION X -X TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS ¢-21 11/16"-.I ` CONDENSATE DRAIN FOR UNIT - LEFT SIDE VIEW 19.0 [3/4[ FEMALE NPT 9/18" POWER CONNECTION Model: 4YCC3048A4088 Voltage Range: 480/3/80 Min. Circuit Ampacity: 11.7 Max. Circuit Breaker. 15.0 Prot R. Recmd: 15.0 ERR/SEER 11.0/13.0 Noise Rating # : 80.0 COMPRESSOR Number. Phase: Rated Load Amps: Locked Rotor Amps: 1 3 7.05 48.0 GAS HEAT Type of Gas: NATURAL Capacity BTUH: 98000 Temp. Rise F (Min./Mb): 3060 Gas Size Pipe: OUTDOOR MOTOR Number. Horsepower. Phase Full Load Amps: Locked Rotor Amps: 1 0.25 1 0.74 1.6 REFRIGERANT Type T1-410 Factory rge 8.2 lb INDOOR MOTOR Number. Horsepower. Motor Speed (RPM): Phase Full Load Amps: Locked Rotor Amps: 0.75 1080 2.2 4.38 Unit Dimensions -1.5-5 ton Pkgd. Gas/Elec. Rooftop Convert. R- 410A,R -22 Item: Al Qty: 1 ELECTRICAL / GENERAL DATA NOTES: 1. Capacity rated in accordance with AR.I. Standard 210240. Noise rated in accordance with ARI. standard 270. ARI. standard rating conditions are: 80 D.B. 87 W.B. entering air to indoor coil 9513.B. entering air to outdoor coil. 2. All models are U.L fisted. Ratings shown are for elevations w to 2000 feet For higher elevations reduce ratings at the rate of 4 percent per 1000 feet elevation. 3. Based on U. S. Government Standard Tests. 4. Unit ships on high input and is convertible to low input with a low fire accessory kit. 5. Convertible to LPG with orifice change. UNIT WEIGHT CORNER WEIGHT CENTER OF GRAVITY SHIPPING NET W1 W2 W3 W4 WS W8 A B 1553.0112 525.0 b 278.0 b 249.0 b 111.0112 '188.0Ib 149.0 b V0.0112 771/2" 28 5/18" CLEARANCE TO COMBUSTIBLE MATERIAL RECOMMENDED SERVICE CLEARANCE BOTTOM 0 UNIT WITH O.A. DAMPER/ECON. WITH 2 POS. DAMPER BACK SIDE 1" BACK SIDE 12" 24" LEFT SIDE 6" LEFT SIDE 38" 42" RIGHT SIDE 8" RIGHT SIDE 42" FRONT SIDE 12" FRONT SIDE 47' TOP 38" Weight, Clearance & Rigging Diagram -1.5 -5 ton Pkgd. Gas /Elec. Rooftop Convert. R- 410A,R -22 Item: Al Qty:1 wil W4 W2 W5 FLUE HOOD CENTER OF GRAVITY Accessory -1.5 -5 ton Pkgd. Gas /Elec. Rooftop Convert. R -410A,R -22 Item: Al Qty: I ECONOMIZER RAIN HOOD 24 318" DOWN FLOW ECONOMIZER RAIN HOOD WIRE COLOR CFSGNATION ABER COLOR INN COLOR BR BLACK PR PURPLE SL BLUE RD RED Ht MOWN M/ MITE GR GREEN YL YELLOW OR GRANGE Field Wiring -1.5 -5 ton Pkgd. Gas/Elec. Rooftop Convert. R- 410A,R -22 Item: Al Qty: 1 III I r r _ _ _� 4 : )Y I I I r 1 — � NC(Npw: I III I r _ _ - - — p ` JL WA R III I II II r • I 111 I I I • I PH ▪ I RAW ! TYPICAL 2 STAGE Y IEATTiF7MAOSTAT POWER UNIT NOTE 1 00 PACKAGED GAS-ELECTRIC UNIT UNIT CONTROL BOX TWO STAGE FEAT TERMOSTATCOIIECRONS { UNIT LOW VOLTAGE AREA NOTES: TYPICAL 1 STAGE EAT T1WOSTAT NOTE6 SNGLE STAGE THERMOSTAT CONNECTIONS 26(BL) 8 pA9V NA(YL Y N Aq WI 4 1C(BRj W2 N6A(RD) R ITLOW VOLTAGE AREA CO68LON FAN OPPRESSOR IEATFIRST STAGE TEAT SECOND STAGE 2WV LATER .COMPONTENT WIRNEI NV. FACTORY LINE V. WIRING - 24V. FIELD LINE V. WIRING FAN CO6PNESSOR HEAT FRET STACIE FEAT SECOND STAGE 24V 1. FUSED DISCONNECT SIZE, POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLYNRIH CODES. S BE SURE POWER SUPPLY AGREES WITH EQUIPMENT AND HEATER NAMEPLATE. 3. LOW VOLTAGE WIRING TO BE 18 AWO MINIMUM CONEUCTOR. 4. SEE UNIT D AGRAM POR ELECTRICAL CONNECTION DETAILS. S THE THERMOSTAT ON THE GASIELECTRIC UNIT MUST PROVIDE A 4 SIGNAL N THE COOLING MODE ONLY. DURING THE HEATING MODE THE FAN WILL BE ENERGIZED BY THE SYSTEM. Q FOR SINGLE STAGE THERMOSTATS JUMPER W1 AND W2 TOGETHER. SECOND STAGE HEAT WILL BEGIN 10 MINUTES AFTER FIRST STAGE ECONOMIZER ACCESSORY TOECONQRER CONNECTIONS FACTOR'PROVIED FELD NSULLED WIRES LNT VOLTAGE AREA 26 E1 01 4 R 26B(BL)13 r « I 1410 MM TYPICAL 2STAGE TERMOSTAT REID INSTALLED JUMPER 4TAGINO 44A(YL) Y Q 41A(Bf5W1 I I I r r - 41cG)wW2 I I r- SL _ ACRD) R Field Installed Option Description Part/Ordering Number 1 -2" Filter frame BAYFLTR201A Crankcase heater BAYCCHT404B , 0 -100% Mod. economizer w/bar. relief BAYECON102A Item Tag(s) Qty Description Model Number Al No Tag 1 1.5-5 ton Pkgd. Gas/Elec. Rooftop Conver 4YCC3048 -4096 Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family -1.5 -5 ton Pkgd. Gas/Elec. Rooftop Convert. R- 410A,R -22 From .11 To Co. +f Co. /Dept - !} ' �� . . „ J_ ,t �- Phon # (503) 620 -$031 Phone # Fax # (503) 639 -1454 Fm # 3 to b - s c U . I c1 / d YCCO35F3MOB 2135-230/3/60 YCCO35F3H0B 208- Z30/3/60 Y00036FWHDB 575/3/00 ?,IDBEL RATER VOLTS Z A.R.I. RATINGS (COOUNG)D BTOH Indoor Air Flow (CFM) System Power (KW) EER/SEER (RTU/WAfT -HR.) Noise Rating No. A.G.A. HATINGs (HEATING)GP (High) Input BTUII Capacity Bil)H ®u ARE Temp. Rise "F (M n./Mu) (Low) Inappuai FUR AFUE /CSE Temp. Rise 'F (Min./Max.) Type of Gas3: PUWER CONNS. - V/PH/HZ Min. Brdi. Ct. Ampocity Br. Cir. - Max. (Amps) Prot. Rtq. - Rocmd. (Amps) COMPRESSOR Na Used Vofts/PH/HZZ RI Amps - L.R. Am I s OUTDOOR COIL TYPE Rays / F.P.I. Fare Area tSo. Ft.) Tube See (in.) INDOOR COIL - TYPE Rows / F.P_I. Fare Area (Sq. Ft) Tuba Fin (in.) Refrigerant Control Dram Corm. SSte (h) Duct Camec lout OUTDOOR FAN - TYPE No. Used / as 6n.) Type Drive / No- Speed, Na. Mat= - HP Motor Speed R.P.M. Vohs/12 - Amps - LR. Amps INDOOR MN - TYPE pia x Width ( Na. Used Drive / Speeds (No -) No. Motors - RP Meta Speed R.P.M. Vans /HZ F.L Anus - LR. Amps COMBUSTION FAN - TYPE Drive - Speeds (N0.) Motor HP --- Speed (RPM) Valts/PH/HZ F.L Amps FILTER - FURNISHED? Type Retrnmendod Min. Face Area-Lo (tt)3: REFRIGERANT Charge (Ibs. of R•22)W GAS PIPE SIZE (IN.) OIMENS1ONS elated L1 ed ) 10 35400 1200 3.73 9.50 / 10.00 8.0 48000 7 380 30/65 32 0 78 %/76% NATURAL 208- 230/3/60 18 25 25 C IMATUFr 1 200 230/3/60 11 - 101 PLATE FIN 2/20 8.34 3/8 COPPER PLATE FIN 3/15 3.96 3/8 COPPER 3/4" FEMALE NKr SEE OUTLINE ORPIJSNG PROPELLER 1/18 DIRECT / 1 1 -1/5 1080 230/1/60 1.6 - 3.3 CENTRIFUGAL 30 X 9 DIRECT / 1--1/3 1080 200- 220/1/80 2.8/22 -- 5.1 CENTRIFUGAL DIRECT -1 - 3480 240/ 0.6 NO THRONITWAY 4.0 5.7 lbs. 1/2" HXWX0 35 -1 /4X 3$ X 57 SEE OUTLINE DRAINING General Data 35400 1200 3.73 9.50 / 10,00 5.0 100000 80000 45/75 tem 78 %/70% 45 -75 NATURAL 208- 2311/3/60 18 25 25 CUMATUFF" 1 200- 230/3/60 11 -101 PLATE FIN 2/20 6.34 3/8 PLATE FIN 3/15 3.96 CAPILLARY 3/4" FEMALE SEE OUTLINE DRAWING PROPELLER 1/18 DIRECT/1 1 -1/5 1080 230/1/60 1.6 - 3.3 CENTRIFUGAL 101 9 DIRECT / 2 1 »3 200 - 230/1/80 2.8/2.2 - 5.1 CENTRIFUGAL DIRECT -1 1/35 - 3480 208 - 240/1/60 0.6 NO THROWAWAY 4.0 5 lbs. 15 ca. 1/2" HXWXD 351/4 X 38 X 64.5/8 SEE OUTLINE DRAINING 35400 1200 3.73 9.50 / 10.00 8.0 100000 80000 78% 45/75 80000 84000 78%176% NATURAL 460/3/60 / 15 15 CUMATUFF" 1 460/3/60 4 - 51.0 PLATE RN 2/20 3/8 PLATE RN 3/15 3.96 3/8 3/4" FEMALE SEE OUTLINE DRAWING PROPELLER 1/18 DIRECT / 1 1 1080 480/1/50 1.7 -3.8 cENTRSFUGAL 10X9 DIRECT / 2 1 - 1/3 460/1/60 1.1- 2.8 CENTRIFUGAL DIRECT -1 1/35 - 3480 208- 240/1/60 0.6 NO THROWO AY 5 Or. 15 co_ I/2" HXWXD 35- 1/4X38 X64-5/8 SEE 011111EIE BRINING 35400 1200 3.73 9.50 /10 -00 8.0 1110300 7 8� 45/75 80000 640(10 78 %/76% 45 -75 NATURAL 575/3/60 6.4 10 10 CLIMATUWF" 1 575/3/60 3.3 -41 PLATE FIN 2/20 6.34 3/8 PLATE FIN 3/15 3.95 3/8 3/4" FEMALE SEE OUTLINE DRANIN6 PROPELLER 1 DIRECT / 1 1 1080 575/1 /60 1.4 - 3.2 ce mfUSAL 10 X 9 DIRECT / 1 -1/3 57 .9 - 2.0 CENTRIFUGAL DIRECT - 1 1/35 - 3480 208 -240/1 /60 0.5 NO THROWAWAY 5 lbs. 15 oz. 1/2 HXwxD 35-1 /4 X 38 X 646/8 SEE OUTLINE DMP)MNG WEIGHT - --�r 811141w Ohs.) / NEL Ohs.) See notes on page 14 426 / 386 452/403 440 / 394 i t 0 7777 - 4 -- 1/ • .} / ' #ol f I pales F r 76 9 1 _ I_ • Co. TRAN Co./Dept 44 . 4 .. k " t " ` - OI Phone # (503) 620.6031 Ph # Fax # (503) 639 -1454 Fa " # 3(00 - S 91 . 19/4 MOQE RATED VOLTS/PH/HZ IL t RATINGS (COG )o UNG Indoor Air Haw (CFM) em Power ()OM SEER No a RRaty No HR) A.GA . RATINGS (HEA PJCW RIM Nut BTU( Capacity BT{JH23st AWE Temp. Rise "F (Min. /Max.) (I orv) Input FUR A�CSE/ Temp. Rise "F 4Min./Ma .) Type of Gast POWER CORNS. - V/PH/HZ .n. Rick r. B A s Br. (�. -M Max ( ) Prot. Rtg. -- Rearm (Amps) COMPRESSOR No. Used Wits/PH/HZ RI Amps -- L.R. Amps OUTDOOR COIL - TYPE Rows / F.P.I. Face Area (Sq. Ft.) Tube Sae (in.l INDOOR COIL - TYPE Rows / Face Moo (Sq. Ft) Tube Size (in-1 Refrigerant Control Drain Cam. Sus (in.) Data Connections OUTDOOR FAN - TYPE No. Used / Diia Cm.) Type Drive / No. Speeds No. Motors - HP Motor Speed R.P.M. Volts/PH /HZ FL Am - LE_ Amps INDOOR FAN - TYPE Ora x Width Lin_) Na Used Drive / Speeds (No.) Na. Motors - HP Motor Speed R.P.M. Volts/PH /HZ FL Amps - LR. Amps COMBUSTION FAN - TYPE Drive - Spuds (NA.) Motor HP - Speed (PPM) Volts/PH/HZ FL Amps FILTER - FURNISHED? Type Recommended M'm_ Face Are. -Lo lft.)i REFRIGERANT Charge (lbs. of R-22)€ GAS PIPE SIZE (IN.) DIMENSIONS U ad (in.) WEIGHT Shi (lbs.) / Net (Ibs.) Sea notes on page 14 10 YCCO36E3MOB 208 -230/ 3/60 35400 3� 9.50 / 10.00 8.0 48000 7 380000 30/65 40000 32000 78%/75% 30 - 65 NATURAL 208- 230/3/60 18 25 25 CUMATUFF"' 1 200 - 230/3/80 11 - 101 PLATE FIN 2/20 6.34 3/9 COPPER PLATE FIN 3/15 3.98 3/8 P COPPER 3/4" FEMALE NPT SEE OUTLINE ORN/ING PROPELLER 1/18 DIRECT / 1 1 -1/5 1080 230/1/60 1.6 - 3.3 CENTRIFUGAL 10X9 1 DIRECT / 1-- 1080 200 - 230/1/60 2.8/22 - 5.1 CENTRIFUGAL DIRECT .-1 240// 0.6 NO THRI INNAY 4.0 HXWXD 35 1/4X SEE OUTLINE DRA5rvirep 426 / 385 General Data YCC.I35F31100 206. 230/3/60 35400 1200 9.50 / 10.00 8.0 100000 80000 46/75 80000 7 45 -75 NATURAL 208 - 230/3/60 18 25 25 CUMATIIFF 1 200- 230/3/60 11 -101 PLATE FIN 2/ 36 PLATE FIN 3/15 396 CAPILLARY 3/4" FEMALE SEE OUTLINE CRANING PROPELLER 1 DIRECT / 1 1 -1/5 1080 230/1/60 1.6 - 3.3 CENTRIFUGAL 10 X 9 1 DIRECT / 2 1 - 1/3 200 - 2 2.8/23 -5.1 CENTRIFUGAL DIRECT -1 1/35 - 3480 208- 240/1/60 0.6 NO THROWAWAY 4.0 HXWXD 35 X 38 X 64 SEE OUTLINE CRANING 452 / 403' 35400 12013 3.73 9.50 / 10.00 8.0 100000 80000 78% 45 / 75 80000 64000 701/78% 45 -75 NATURAL 480/8/60 15 8 15 CUMATUFF' 1 460/3/60 4 --51.0 PLATE FIN 8� 3/8 PLATE FIN 3/8 CAPILLARY 3/4" FEMALE SEE OUTUNE DRONING PROPELLER 1/18 DIRECT / 1 1 1080 400/1/60 1.7 - 3.8 CENTRIFUGAL 10X9 1 DIRECT / 2 1 1080 480/1/60 1.1- 2.6 CENTRIFUGAL DIRECT - 1 1/35 - 3480 2011-2413/1/60 0.6 NO THROWAWAY 4.0 5tbs_15 1/2" HXWXD 35-1/4 X 38 X 54-5/8 SEE OUTLINE DRONING 440 / 394 YCCO35FWIIOR 575/3/60 35400 1200 3.73 9_50 /101X1 8.0 100000 80000 45/75 80000 78 45 -75 NATURAL 575/3/60 6.4 10 10 575/3/60 3.3 -41 PLATE FIN 2/20 3 PLATE FIN 3 /15 3/8 CAPILLARil 3/4" FEMALE SEE OUTLINE DRAWING PROPELLDI DIRECT / 1 1 1080 575/1 /60 1.4 - 3.2 CEN)RJFU&AL 10 X 9 1 DIRECT / 1--1/3 Ia 575/ .9 ---2.0 CENTRIFUGAL DIRECT -1 1/35 - 3480 208-240/1/60 NO THROWAWAY 4 5 Ibs.15 ar. HXWXD 35.1/4X38X64-5/8 • S� 1)1/fiNE DROMNG 440 394 11 -06 -2007 TIM HOLLIPETER 6603 N E 137 AV VANCOUVER WA 98682 RE: Permit No. M07 -122 6750 S 180 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writinf and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 12/05/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, II xc: fer Marshall, t Technician Permit File No. M07 -122 City of Tukwila Steven M. Mullet, Mayo Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M07 -122 DATE: 06 -01 -07 PROJECT NAME: BASCO SITE ADDRESS: 6750 S 180 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENT % Buil ng Division Public Works El Complete Documents /routing slip.doc 2 -28-02 PLAN REVIEW /ROUTING SLIP Fir e Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Planning Division n ❑ Permit Coordinator ❑ DUE DATE: 06-05 -07 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTI G: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07-03 -07 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 WESTERN SURETY CO 14714206 06/10/2005 Until Cancelled $6,000.00 06/13/2005 Business Owner Information Name Role Effective Date Expiration Date HARMON, BRENDA 06 /13/2005 HARMON, JEREMY PRESIDENT 06 /13/2005 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License TRITEHI952LL TRI -TECH HEATING INC CONSTRUCTION CONTRACTOR 602255131 87916201 CORPORATION 6603 NE 137TH AVE VANCOUVER CLARK WA 98682 3608912002 ACTIVE AIR CONDITIONING UNUSED 6/13/2005 6/13/2009 TRITEH *077NF https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= TRITEHI952LL 06/08/2007 C 05 C 1 C • CS Go z Q • TANK 7' FILL W! ROCK NORTH LINE OF GOVERNMENT LOT 1 FENCE CORNER IS 1.4' SOUTH OF THE PROPERTY UNE. PAVEMENT CORNER IS 0.6' SOUTH OF THE PROPERTY LINE.' - � N8744'08 "W 949.49'_ --__ SHAST ac FENCE CORNER IS 0.8' SOUTH .OF THE PROPERTY UNE. S 8808'21 "E 'C' s CCMPACT (8'46' INCL. 2' MONO) S' WIDE GAS PIPEUNE EASMENT TO WASHINGTON NATURAL GAS COMPANY FOR GAS PIPEUNE REC. NO. 9503300236. 300.00' FIRST FLOOR TOTAL: OFFICE ( ) Wd HOUSE (SU PRODUCTION a5) $140P (F) flgagara 6ECCND FLOOR TOTAL: 51•Ic1I ROCh1(A -3) OFFICE (8) S° Y∎PA s (8) — PARKING IN THIS AREA BY EMPLOYEES OF SHASTA BEVERAGES 46,168 SP. 8311 SF. 16302 SP 18351 SF. 2388 SE 4318 SF. 1358 SF 1.010 SF. 1,650 SP PARKNG RECURRED: CFFK 4CT. /1000 * 10 * 26 CARS WAREHOUSE / I U1000. 39,412 ■ 39.4 CARS 65 CARS PARKING 5 N: 68 NCLUDNG (3 14C, i3 COMPACT, 46 STANDARD) EDGE OF PAVEMENT IS SOUTH OF THE PROPER 6' CHAINLINK FENCE FENCE IS 1.0' WEST OF THE PROPERTY UNE EAVE IS 0.7' WEST ' ,OF THE PROPERTY LINID: 4 NEW TMES 1 -STORY CONCRETE BUILDING 1233 ANDOVER ARK EAST ,324 53' • V 6° - pF vg � \ c L F t HRST FLOOR TOTAL: OFFICE (B) (SU SECOND FLOOR TOTAL: EXISTING CAR PARKING. TYPE CONSTRUCTION: IIH - ZONNG: URBAN CENTER TAX a 3523 -0490 6' LINE. 45,662 SF. 4,658 SE 41p04 SF 4,158 5F 65 SPRINKLERDD (1955) LEGEND - I. PROVIDE mu SINGLE PLY PVC ROOFING SYSTEM OVER EXISTING BUILT-UP ROOF. 2. PROVIDE ALTEMATE PRICE FOR SINGLE PLY TORGI•IZ701W ROCFNG SYSTE 1 IW COVER BOAR] OVER EXISTIFIG ROCFddG. 3. PROVIDE ALTERNATE PRICE FOR REMOVAL 4 PROPER DISPOSAL GE USING ROOFING PRIOR TO RE-ROCFM 1W EITHER PVC CR TORCIVOUJN ROCFM SYSTEMS. 4. PROVIDE ALL NECESSARY FLAA5HII4SS 4 ASSESSOR ES TO PROVIDE FULL WARRANTY. 5. PROVIDE 20 YEAR RLL MFLACEMENT WARRANTY FOR ROCMG SYSTEM MULLED. 2 —STORY CONCRETE BUILDING 6750 SOUTH 180TH STREET TYPICAL. NEW 4' X 8' SI'1OKE VENT SKYLIGHT FER LFC 81026.14 8102bb SEE MS. I/A -I 4 2/A -I i 0 t� 01!: o t9 a 6l -- -- ' 0 le � 6 o r) ra D D ■ �'1•. SEMOvE EXISTNG AS NALT PAVING 4 BASE. CCP1PAGT 4 RE- NSTALL 4' ROCK BASE. INSTALL NEW 2' A5F1•IALT PAYING 4 STRIPING. R.O.S. REC. NO. 8509249015 VALLEY PROPERTIES f • FIRE DEPARTMENT CONNECTION + POST INDICATOR VALVE — W —WATER LINE — G — GAS LINE TELECOMMUNICATIONS JUNCTION LIGHT VAULT POWER VAULT SIGNAL VAULT WATER METER CATCH BASIN III GAS VALVE — S — SANITARY SEWER SANITARY SEWER UNE MANHOLE BOX 1 r7 DEC 0 5 2007 N.E. CORNER OF GO .f. LOT 1 I O7 J22 y t 449.59' F -3t1 W w 0 '°- I 6 25 36 DEEDED MERIDIAN 20 10 '0 20 GRAPHICAL SCALE: 1" = 20' IEVIEW COMPLIANCE CODE APPROVED JUN - 5 2 07 ty Of Tukwila BUILDING QJLJON S 'RATE PBRmir ❑ Mechankal V E l ectrical 'plumbing is Piping City of Tukwila BUILDING DS Permit No. Plan review approval Is subs to emirs and om1 Approval of constru*•on d� does not authorize the vlolat; ^^ I acep:ed code or ordina r e. of apprc. �1 Is a Wedged: d Date:‘ City of Tukwila BUILDING DIVISION 3 - 63 ' Welkin* No changes shall ba made to the sop c v,c:-oc without prior a pproval cif yr' ' a r. W LIGHT POLE RAILROAD SIGNAL POLE l4 WATER VALVE WATER VAULT R FIRE HYDRANT A POWER METER ® POWER TRANSFORMER P ▪ HANDICAP PARKING STALL EDGE OF ASPHALT CONCRETE SURFACE FOUND "4X4" CONCRETE MONUMENT WITH BRASS TACK IN CASE RECEWED JUN -1 2007 PERMIT CEN1 ER w cco 00 00 I I re) CD NI N CD CD N N W ox Q L nn .�nr ,r'- 4' ec-7 ( t kin ev I J�:..A1'