Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-136 - WESTFIELD SOUTHCENTER MALL - GAME STOP
GAMESTOP 2616 SOUTHCENTER MALL M07 -136 Parcel No.: Address: Suite No: City-of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2616 SOUTHCENTER MALL TUKW Tenant: Name: GAME STOP Address: 2616 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: Address: Contractor: Name: ROB HUMPHREY 833 SE MAIN ST #242 , PORTLAND OR EMERALD AIRE INC. Address: 22043 68TH AVENUE SOUTH , KENT, WA Contractor License No: EMERAAI055BL DESCRIPTION OF WORK: HVAC FOR TENANT IMPROVEMENT FOR NEW MALL SPACE Value of Mechanical: $15,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10 /06 MECHANICAL PERMIT jOUIPMENT TYPE AND OUANTITY 0 0 0 O 0 1 0 0 O 1 0 0 0 0 * *continued on next page ** Permit Number: M07 -136 Issue Date: 05/13/2008 Permit Expires On: 11/09/2008 Phone: Phone: 503 -320 -5030 Phone: 206 872 -5665 Expiration Date: 04/01/2009 Fees Collected: $327.20 International Mechanical Code Edition: 2003 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 8 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -136 Printed: 05-13 -2008 Permit Center Authorized Signature: Signature: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -136 Issue Date: 05/13/2008 Permit Expires On: 11/09/2008 Date: I hereby certify that I have read and exkmi#ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied w_�, specified herein or not. The granting of this • ermit does not resume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o • _ • erformance ork. I am authorial to sign and obtain this mechanical permit. Date: Print Name: ifV <J!' ' 1 ,740 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -136 Printed: 05-13 -2008 City of Tukwila Parcel No.: 6364200010 Address: 2616 SOUTHCENTER MALL TUKW Suite No: Tenant: GAME STOP doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -136 Status: ISSUED Applied Date: 06/08/2007 Issue Date: 05/13/2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. T: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** M07 -136 Printed: 05-13 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 kv (I) Date: V NV P M07 -136 Printed: 05-13 -2008 C Site Address: ' Uj (I S d tJSN{ flJ . " �t L� Tenant Name: tFst -kE 5Top Property Owners Name: IN ESTR 1.9 Ca? Mailing Address: :) &pO '1Jt L$ rh 1+ $t. ✓J 1( 0 Name: Z.'o C 3 j 4 ' - 0Y - 1FM c et- rffiekt T S Mailing Address: Si) se M4 Ipt1 S r 2 VZ E -Mail Address: Zj .03 Q. ‚4jg41 0-+''t Company Name: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E-Mail Address: a.ommunhry ueve:opmer - •,eparrmenr Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us •o 1 )1V Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 0-Z01 S Cg is -L A- L S-0 (LPti &- - R- . fie e Rep 3vo Contact Person: E-Mail Address: Q:MppliationsTotms- Applatta s On Line\3.2006 • Permit Apptieation.doc Revised: 9-2006 bb King Co Assessor's Tax No.: Suite Number: 2, 1 O S Floor: New Tenant: .... Yes 145 4✓ t,i� City State 4 1 00 1-S Zip Day Telephone: �3 -3 ?A -- .r03 0 QAL;' d.�. 97z aty state p Fax Number: S Zq — t 63 0 Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Zip 5� 1,o�rs AA (03 (k/- Day Telephone: 3 i t/ - (3_ Z Oa Fax Number: 7( 4 / - '- (.t` - t306 Company Name: Mailing Address: Zip City Day Telephone: Fax Number: Page 1 of 6 - e JIIIt b'P ' 4 t rni t TYI? w r ? ' '. ' . R it -Tape ' , , s p> er JC otprescr Furn BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator - Comm/Ind MECHANICAL CONTRACTOR INF /IATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ j Cr Scope of Work (please provide detailed information): !s1 i,(J i Z44/ F C.t ar✓ e' q( t9 - TO /S TIR j t/'(LY Pier - b d�7 - vJ'l Use: Residential: New .... Replacement .. -. Commercial: New .... ►'�► Replacement .... Fuel Type: Electric..X Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: QMppliationsWonns- Applications On Line 3 -2006 - Permit Appliation.doe Revised: 9 -2006 bh Page 4 of 6 Value of Construction —In all cases, a value!! construction amount should be entered by the applicant. This figure will be reviewed and is subject so possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: I -z3 t4t/dAl FH1- E t J r" Ye MA-trt) Mailing Address: Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Date Application Expuros., Date Application Accepted: (0 S Q: Mppliatio Porno- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh i ex ?algal Day Telephone: x - z 7 Z 204:1" LAM City Date: 8 -" 0 7 State 42 / 7 Zip Staff Initials: �w Page 6 of 6 RECEIPT NO: R08 -01588 Initials: WER User ID: 1655 Payee: EMERALD AIRE, INC. SET TRANSACTIONS: Set Member Amount EL08 -558 58.00 EL08 -559 58.00 EL08 -560 62.00 M07 -136 267.76 TOTAL: 445.76 ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www. ci. tukwila. wa. us ELECTRICAL PERMIT - NONR MECHANICAL - NONRES SET RECEIPT Payment Date: 05/13/2008 Total Payment: 445.76 SET ID: 0513 SET NAME: EMERALD AIRE TRANSACTION LIST: Type Method Description Amount Payment Check 1176 445.76 TOTAL: 445.76 Account Code Current Pmts 000.322.101.00.0 178.00 000/322.100 267.76 TOTAL: 445.76 2348 05/13 9711 TOTAL 445.76 Receipt No.: R07 -01085 Payee: PRECISION PERMIT SERVICE TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES O City f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: M07 -136 Address: 1004 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/08/2007 Applicant: GAMESTOP Issue Date: Initials: WER Payment Date: 06/08/2007 03:53 PM User ID: 1655 Balance: $267.76 Amount Payment Check 4578 59.44 Account Code Current Pmts 000/345.830 59.44 Total: $59.44 Payment Amount: $59.44 9219 06/11 0716 TOTAL 759.98 doc: Receiot -06 Printed: 06-08 -2007 Project:A (ia 1/e - 7 Type of Inspection: . niel Address: L /4 � // 7 � r Date Called: Special Instructions: Date Wanted: 7 //74 4 a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: / " /7 r/ e 4 7 J fe7 r 0 1 lnsper: (Date: 2/ 7/ 00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: i 1 P1 X7 —)3 I PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 - (206)431 -3670 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Proje 14 STOP Address: ( Yv X(it4 Special Instructions: Type of Inspection: F t Date Called: Date tar: Requester: Phone No: El 26,2 -S ))(1-01(5--7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6 eldiCia,//e4 'Inspector: 'Date: JJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r eceipt No.: 'Date: • I rt'oi - i & I PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Z ia") {eV Address: 26 I Tt' Special Instructions: Type of Inspection: S 'oke Sko w Date Called: Date Wanted: 7 / »i /o? a.m. p.m. Requester: Phone No: 2 t'2:"qi4- 674/ Approved per applicable codes. Q Corrections required prior to approval. COMMENTS: v V —, 1 4tl1re; io �2_ -Pwsve4 Su ✓t S 1Ari: 1 LAc -Z i3 (Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1Date: 7//q /v 'J $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Iper7-0,1 D Approved per applicable codes. r Corrections required prior to approval. COMMENTS: /37/4 ,Ueci. O/c ar c et )1YLC/ Goverr- _,_ 0z`.. ' Date:5 /29 l OM. INSPECTION FEE REQUIRED. Prior to inspection, fee must be pai 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: !Date: INSPECTION RECORD I Retain a copy with permit NO. PY P mit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1� 6300 Southcenter Blvd., #100,.Tukwila, WA 98188 (206)431 -3670 Project: C7 4P S Address: /6 r �� Special Instructions: /?10 - / 3 G Type of lnspecti Date Called: ugh . 1 Date Wanted: 572 ? +�. p .:: u Requester: Phone No: . Z 9/96X0 c 16 COMMENTS: Approved per applicable codes. J Corrections required prior to approval. IDat /� Or 1 $58.OtEINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: GiAvi-te,_ d) P Sprinklers: -- Type of Insp ion: c P }=vt_X)L. \ in A e (I Address: ‘.,1 ( Suite #: 5 .c hl A I L Contact Pe n: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: -- Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -44 [Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 3 /v7 d - `t - /.36 PERMIT NUMBERS El Corrections required prior to approval. COMMENTS: Eyre Ss /, " t) (cAy Inspector: ,‘ 3 - i y I Date: '2 /fit / Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 11 -06 -2007 ROB HUMPHREY 833 SE MAIN ST #242 PORTLAND OR 97214 RE: Permit Application No. M07 -136 Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 06/08/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 12/05/2007 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 12/05/2007. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Ter Marshall 't Technician Permit File No. M07 -136 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -136 DATE: 06-08-07 PROJECT NAME: GAMESTOP SITE ADDRESS: t 14 /(i ''SOUTHCENTER MALL X Original Plan Submittal _ Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bu dl g Dkon Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Please Route TUES/THURS R UTING: APPROVALS OR CORRECTIONS: X11 nix- ( -5 Fire Prevention Structural Review Required Planning Division Structural ❑ Permit Coordinator Incomplete Comments: o DUE DATE: 06 -12 -07 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:_ ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 07 -10 -07 Approved ❑ Approved with Conditions 0 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 License Information License EMERAAI055BL Licensee Name EMERALD AIRE INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600591552 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 5108 D STREET NW Address 2 06/01 /2000 City AUBURN County KING State WA Zip 98001 Phone 2538725665 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/13/1995 Expiration Date 4/1/2009 Suspend Date Separation Date Parent Company Previous License SOUNDAI 158OW Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HAPPE, DOUGLAS A PRESIDENT 01/01/2000 RIDGE, JOHN P VICE PRESIDENT 01/01/2000 RICHARDS, RON SECRETARY 01/13/1995 06/01 /2000 TREMAINE, DAVIS WRIGHT AGENT 01/13/1995 12/31/1999 DUPUIS - FRICKE, LINDA PRESIDENT 01/13/1995 12/31/1999 HAPPE, DOUGLAS A PRESIDENT 01/13/1995 12/31/1999 sk Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= EMERAAI055BL 05/13/2008 AIR DEVICE SCHEDULE 0 PLAN MARK Q � *TITUS MODEL NO. FACE SIZE NECK SIZE FLEX SIZE TYPE NOTES A 5 TDCA- 3/AG -95 24 "x24" 10" RD. 10" RD. DIFF. 1,2,3 B 1 TDCA- 3/AG -95 12 "x12" 6" RD. 6" RD. DIFF. 1,2,3 C 2 50 F 24 "x24" 22 "x22" N/A R.G. 1,3 NOTES: PLAN FOR THROW PATTERN SHALL FIT LAY —IN CEILING MODULE & INSTALL MANUAL VOLUME DAMPER 1. REFER TO 2. FRAME 3. PROVIDE FAN POWERED VAV WA 1 WHEEDLE (WW -1) MANUFACTURER MODEL NO. MINIMUM AIR CFM TOTAL CFM INLET SIZE TRANE (OR EQUAL) VPEF125MT.52775TDE105L480315 MAGN 380 1300 12 DISCHARGE SIZE BASE UNIT WEIGHT FAN SIZE FAN HP VOLTS PH ELECTRIC HEAT HZ MCA 20 "x20" 128 LBS 05 1 /2 277 1 5.0 KW ©480 3PH 60 10.77 FAN EXHAUST GRILLE CONNECT TO LANDLORD'S TOILET EXHAUST DUCT STUB —IN OR NEW DUCT THROUGH ROOF. REFER TO KEYED NOTES. 1" INSULATED BOX BACKDRAFT DAMPER TOILET EXHAUST DETAIL SCALE NONE DUCT HANGER DETAIL I SCALE NOM ROOF JOIST HANGER WIRE SHEET MIL. DUCT HANGER RECTANGULAR DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS CLEVIS HANGER OVERSIZED FOR INSULATION WITH 18" ROLLED SLEEVE FOR SUPPORT 180' PIPE HANGER DETAIL ecue NONE HANGER SPACING AND ROD SIZE PIPE SIZE 1/2" 3/4" 1 1 1/4" 1 1/2" 2 " 2 1/2" 3 3 1/2" 4" 5" 6 " 10" 12" 14 16" 18" 20" 24 MAX SPAN 7 7' 7' 7' 9' 10' 11' 12' 13' 14' 16' 17' 19' 22' 23' 25' 27' 28' 30' 32' ROD SIZE 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 5/8" 3/4" 3/4" 7/8" 1" 1" 1 1/4" 1 1/4" LANDLORD'S SUPPLY AIR DUCT MAIN N.P. FLEX DUCT MAX. 1' -0" 115V WIRING & J —BOX BY ELECTRICAL CONTRACTOR J —BOX ELECTRONIC * THERMOSTAT WIRING -f I DAMPER BY HVAC CONTRACTOR MEDIUM TO HIGH PRESSURE DUCT * FOLLOW MANUFACTURER'S WIRING DIAGRAM ROOM THERMOSTAT VAV BOX CONNECTION DETAIL ecaB xarE HANGERS (TYP. OF 4) VAV BOX 2" WIDE MIN. DUCT STRAP 48" Q.C. MAX. RIGID ROUND METAL DUCT EXTERNALLY INSULATED RIGID ROUND DUCT ELBOW EXTERNALLY INS ULATED INSULATED FLEXIBLE DUCT MAX. LENGTH 5' -0'. FIRE DAMPER (LOCATION WHEN REQUIRED) VOLUME DAMPER (FOR FINAL BALANCE ADJUSTMENT) SPIN —IN FITTING WITH BALANCING DAMPER AND 45' EXTRACTOR (DAMPER USED FOR ROUGH BALANCING) DIFFUSER CEILING HVAC DUCTWORK DETAIL SCAB NONE METAL SUPPLY DUCT EXTERNALLY INSULATED )///// ....m )///// ROOF JOIST „--- HANGER WIRE SHEET MIL. DUCT HANGER fr4‘. SPIRAL DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS ROUND DUCT HANGER DETAIL SCALD NOM MECHANICAL CONTRACTOR'S NOTES ALL OF THE MECHANICAL & SPRINKLER WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED, BUT ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REP- RESENTATIVE, SHALL BE PART OF THIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED AS EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED, DUE TO EXTRA WORK MADE NECESSARY BY THE CONTRACTOR'S FAILURE TO VISIT THE JOB SITE. * OR APPROVED EQUAL ACCESSORIES, 1. ELECTRONIC CONTROL MECHANICAL PLAN SCALD 1/4' - r-v HVAC + SPRINKLER KEYED NOTES 0 O NEW THERMOSTAT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. COORDINATE WITH ELECTRICAL CONTRACTOR. MOUNTING HEIGHT 4' —O" A.F.F. PROVIDE LOCKING LUCITE COVER. TURN KEY OVER TO STORE MANAGER. • COMBINATION EXHAUST FAN /LIGHT. NUTONE MODEL #8664RP, 4 "0 DUCT SIZE, FAN /LIGHT HOUSING 9 "x9 "x5 ", 1.2 AMPS, 100 CFM, 3.5 SONES, 115v/1p h/60hz PROVIDE BACKDRAFT DAMPER. EXTEND NEW EXHAUST DUCT THRU ROOF. ® PROVIDE NEW SPRINKLER HEAD ON TOILET ROOM CEILING. COORDINATE EXACT LOCATION WITH LIGHT/ FAN FIXTURE. MODIFY SUPPLY PIPING AS REQUIRED. 0 PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED TO ACCOMMODATE NEW CEILING (TYP.). COORDINATE EXACT LOCATION WITH NEW CEILING FIXTURES AND LIGHTS. MODIFY SUPPLY PIPING AS REQUIRED. ® NEW FIRE EXTINGUISHER PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT TYPE, QUANTITY AND LOCATION(S) WITH LANDLORD AND LOCAL FIRE MARSHALL. 0 APPROXIMATE LOCATION OF EXISTING SPRINKLER SYSTEM MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. O FLEXIBLE DUCT, MAXIMUM 5' -0" (TYPICAL) PROVIDE SMOOTH TRANSITION AND PROPER SUPPORTS PER SMACNA. USE FLEXIBLE DUCT FOR FINAL RUNOUT TO DIFFUSER ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. 0 NEW 2.5" THICK, .75 PCF EXTERNALLY INSULATED LOW PRESSURE SUPPLY AIR DUCT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. PROVIDE TRANSITIONS AS REQUIRED, DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE AND /OR PRACTICAL IN JOIST SPACE. ® CONTRACTOR TO ENSURE DOOR IS UNDERCUT. COORDINATE WITH GENERAL CONTRACTOR. O. ENSURE TRANSFER AIR OPENINGS WITH FIRE DAMPERS IN DEMISING WALLS ADJACENT TO TENANT'S AS REQUIRED FOR RETURN AIR BACK TO MAIN MALL HVAC UNIT. 11 MALL'S EXISITNG 30 "x24" SUPPLY AIR MAIN. FIELD VERIFY EXACT LOCATION. 12 MALL'S EXISTING 34 "x30" SUPPLY AIR MAIN. FIELD VERIFY EXACT LOCATION. 13 NEW TRANE MODEL FAN POWERED VAV BOX SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. CONNECT TO LANDLORD'S EXISTING SUPPLY AIR DUCT. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. 0 janTaratts be made to scope C ' :: fi t prier cf ..:Vs ;cas will rrq. u'i7 3 a new . e. e r a and m plan review fan. Permit N0. , Plan review approval Is subject to errors and omis Approval of con:ction documents does not auto the violation cf ccce3ced code or ordiriatre. Recal Of appmvcJf * � �� o~d nd; � OnS 15 'sledge)* BY City of Tukwila � BUILDING DON 0 0 { REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 9 2007 B L Ci ,1Of Tukwila ILDING DIVISION SEPARATE PERMIT QUIRED FOR: D Mechanical iltf Electrical "I Plumbing Ga is Piping City of Tukwila BUILDING DIVISION RECEIVE. JUN - 8 2007 PERMIT CENThi HVAC SYMBOLS LEGEND IZI RETURN AIR GRILLE SUPPLY AIR DIFFUSER RETURN AIR SUPPLY AIR AIR DEVICE R.A.G. DIFF. M.D. F.D. F.C. RETURN AIR GRILLE DIFFUSER MANUAL DAMPER FIRE DAMPER FLEXIBLE CONNECTION TYPE AIR VOLUME IN CUBIC FEET /MINUTE (CFM) THERMOSTAT R.A. S.A. ® FAN EXHAUST GRILLE CONNECT TO LANDLORD'S TOILET EXHAUST DUCT STUB —IN OR NEW DUCT THROUGH ROOF. REFER TO KEYED NOTES. 1" INSULATED BOX BACKDRAFT DAMPER TOILET EXHAUST DETAIL SCALE NONE DUCT HANGER DETAIL I SCALE NOM ROOF JOIST HANGER WIRE SHEET MIL. DUCT HANGER RECTANGULAR DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS CLEVIS HANGER OVERSIZED FOR INSULATION WITH 18" ROLLED SLEEVE FOR SUPPORT 180' PIPE HANGER DETAIL ecue NONE HANGER SPACING AND ROD SIZE PIPE SIZE 1/2" 3/4" 1 1 1/4" 1 1/2" 2 " 2 1/2" 3 3 1/2" 4" 5" 6 " 10" 12" 14 16" 18" 20" 24 MAX SPAN 7 7' 7' 7' 9' 10' 11' 12' 13' 14' 16' 17' 19' 22' 23' 25' 27' 28' 30' 32' ROD SIZE 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 5/8" 3/4" 3/4" 7/8" 1" 1" 1 1/4" 1 1/4" LANDLORD'S SUPPLY AIR DUCT MAIN N.P. FLEX DUCT MAX. 1' -0" 115V WIRING & J —BOX BY ELECTRICAL CONTRACTOR J —BOX ELECTRONIC * THERMOSTAT WIRING -f I DAMPER BY HVAC CONTRACTOR MEDIUM TO HIGH PRESSURE DUCT * FOLLOW MANUFACTURER'S WIRING DIAGRAM ROOM THERMOSTAT VAV BOX CONNECTION DETAIL ecaB xarE HANGERS (TYP. OF 4) VAV BOX 2" WIDE MIN. DUCT STRAP 48" Q.C. MAX. RIGID ROUND METAL DUCT EXTERNALLY INSULATED RIGID ROUND DUCT ELBOW EXTERNALLY INS ULATED INSULATED FLEXIBLE DUCT MAX. LENGTH 5' -0'. FIRE DAMPER (LOCATION WHEN REQUIRED) VOLUME DAMPER (FOR FINAL BALANCE ADJUSTMENT) SPIN —IN FITTING WITH BALANCING DAMPER AND 45' EXTRACTOR (DAMPER USED FOR ROUGH BALANCING) DIFFUSER CEILING HVAC DUCTWORK DETAIL SCAB NONE METAL SUPPLY DUCT EXTERNALLY INSULATED )///// ....m )///// ROOF JOIST „--- HANGER WIRE SHEET MIL. DUCT HANGER fr4‘. SPIRAL DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS ROUND DUCT HANGER DETAIL SCALD NOM MECHANICAL CONTRACTOR'S NOTES ALL OF THE MECHANICAL & SPRINKLER WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED, BUT ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REP- RESENTATIVE, SHALL BE PART OF THIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED AS EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED, DUE TO EXTRA WORK MADE NECESSARY BY THE CONTRACTOR'S FAILURE TO VISIT THE JOB SITE. * OR APPROVED EQUAL ACCESSORIES, 1. ELECTRONIC CONTROL MECHANICAL PLAN SCALD 1/4' - r-v HVAC + SPRINKLER KEYED NOTES 0 O NEW THERMOSTAT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. COORDINATE WITH ELECTRICAL CONTRACTOR. MOUNTING HEIGHT 4' —O" A.F.F. PROVIDE LOCKING LUCITE COVER. TURN KEY OVER TO STORE MANAGER. • COMBINATION EXHAUST FAN /LIGHT. NUTONE MODEL #8664RP, 4 "0 DUCT SIZE, FAN /LIGHT HOUSING 9 "x9 "x5 ", 1.2 AMPS, 100 CFM, 3.5 SONES, 115v/1p h/60hz PROVIDE BACKDRAFT DAMPER. EXTEND NEW EXHAUST DUCT THRU ROOF. ® PROVIDE NEW SPRINKLER HEAD ON TOILET ROOM CEILING. COORDINATE EXACT LOCATION WITH LIGHT/ FAN FIXTURE. MODIFY SUPPLY PIPING AS REQUIRED. 0 PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED TO ACCOMMODATE NEW CEILING (TYP.). COORDINATE EXACT LOCATION WITH NEW CEILING FIXTURES AND LIGHTS. MODIFY SUPPLY PIPING AS REQUIRED. ® NEW FIRE EXTINGUISHER PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT TYPE, QUANTITY AND LOCATION(S) WITH LANDLORD AND LOCAL FIRE MARSHALL. 0 APPROXIMATE LOCATION OF EXISTING SPRINKLER SYSTEM MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. O FLEXIBLE DUCT, MAXIMUM 5' -0" (TYPICAL) PROVIDE SMOOTH TRANSITION AND PROPER SUPPORTS PER SMACNA. USE FLEXIBLE DUCT FOR FINAL RUNOUT TO DIFFUSER ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. 0 NEW 2.5" THICK, .75 PCF EXTERNALLY INSULATED LOW PRESSURE SUPPLY AIR DUCT SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. PROVIDE TRANSITIONS AS REQUIRED, DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE AND /OR PRACTICAL IN JOIST SPACE. ® CONTRACTOR TO ENSURE DOOR IS UNDERCUT. COORDINATE WITH GENERAL CONTRACTOR. O. ENSURE TRANSFER AIR OPENINGS WITH FIRE DAMPERS IN DEMISING WALLS ADJACENT TO TENANT'S AS REQUIRED FOR RETURN AIR BACK TO MAIN MALL HVAC UNIT. 11 MALL'S EXISITNG 30 "x24" SUPPLY AIR MAIN. FIELD VERIFY EXACT LOCATION. 12 MALL'S EXISTING 34 "x30" SUPPLY AIR MAIN. FIELD VERIFY EXACT LOCATION. 13 NEW TRANE MODEL FAN POWERED VAV BOX SUPPLIED AND INSTALLED BY HVAC CONTRACTOR. CONNECT TO LANDLORD'S EXISTING SUPPLY AIR DUCT. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. 0 janTaratts be made to scope C ' :: fi t prier cf ..:Vs ;cas will rrq. u'i7 3 a new . e. e r a and m plan review fan. Permit N0. , Plan review approval Is subject to errors and omis Approval of con:ction documents does not auto the violation cf ccce3ced code or ordiriatre. Recal Of appmvcJf * � �� o~d nd; � OnS 15 'sledge)* BY City of Tukwila � BUILDING DON 0 0 { REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 9 2007 B L Ci ,1Of Tukwila ILDING DIVISION SEPARATE PERMIT QUIRED FOR: D Mechanical iltf Electrical "I Plumbing Ga is Piping City of Tukwila BUILDING DIVISION RECEIVE. JUN - 8 2007 PERMIT CENThi GENERAL A. THE GENERAL CONDITIONS OF THE GENERAL SPECIFICATIONS, ALONG WITH ALL APPLICABLE INSTRUCTIONS TO BIDDERS, SHALL FORM A PART OF THIS SECTION OF THE SPECIFICATIONS. B. REFERENCE IS MADE TO REQUISITES FOR BIDDERS AND CONTRACTORS UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, WHICH SHALL BE CONSIDERED BINDING, UNLESS OTHERWISE NOTED UNDER THIS SECTION. SCOPE EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE CONSTRUCTION DETAILS, BOTH ON TENANT CONSTRUCTION DRAWINGS AND LANDLORD'S AS REFERRED TO, BEFORE SUBMITTING HIS BID AS NO ALLOWANCES WILL BE MADE BECAUSE OF CONTRACTOR'S UNFAMILIARITY WITH THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY THE PACE OF THE GENERAL CONSTRUCTION. INSPECTION OF SITE ALL PROPOSALS SHALL PRECLUDE THAT CONTRACTOR IS FAMILIAR WITH JOBSITE CONDITIONS AND UTILITY LOCATIONS AND THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. PERMIT'S ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE SUBCON- TRACTOR INVOLVED. CODE REQUIREMENTS ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS OR AS DIRECTED BY THE OWNER, AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, AND /OR REGULATIONS OF THE GOVERNING BODIES, WHETHER SO SHOWN OR NOT, AND ALL MODIFICATIONS REQUIRED BY SUCH AUTHORITIES SHALL BE MADE BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO OWNER. MATERIALS AND WORKMANSHIP A. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY THE MANUFACTURERS, AND UN- LESS OTHERWISE SPECIFIED SHALL BE NEW, AND FREE FROM ANY AND ALL DEFECTS. LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COM- PETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE MANNER. WORK SHALL BE PROPERLY PROTECTED DURING CON- STRUCTION AND COMPLETION, INSTALLATION SHALL BE THOROUGHLY CLEANED OF ALL DEBRIS PRESENT AS A RESULT OF THIS CONTRACT AND SHALL BE REMOVED FROM THE PREMISES, DO NOT ABANDON. CODES AND REGULATIONS EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN AND SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT A VARIANCE, HE SHALL PROMPTLY NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS, ORDINANCES, RULES AND REGULATIONS AND WITHOUT GIVING SUCH NOTICE, THE SUBCONTRACTOR SHALL BEAR ALL COSTS ARISING THEREFROM. PROTECTION OF WORK AND PROPERTY A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL HIS WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS WORK. ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND NOT TO HIS FAULT OR NEGLIGENCE, SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR. HE SHALL ADEQUATELY PROTECT ADJACENT PROPERTY AS WELL. B. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFETY OF THEIR EMPLOYEES ON THE WORK AND SHALL COMPLY WITH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN ALL INSURANCE REQUIRED TO PROTECT HIMSELF, THE OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST PROPERTY DAMAGE AND PUBLIC LIABILITY. CHANGES IN THE WORK THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK, WITH CONTRACT SUM BEING ADJUSTED ACCORDINGLY. COOPERATION ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE SUF- FICIENT TIME AT THE PROPER STAGE OF CONSTRUCTION TO FULFILL HIS CONTRACTS. CONTRACTORS SHALL CONTACT OWNER FOR INSTRUCTIONS SHOULD ANY QUESTIONS ARISE BETWEEN TRADES AS TO THE INSTALL- ATION OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR SHOULD IT APPEAR DESIRABLE TO ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE OR STRENGTH OF THE STRUCTURE. SUBSTITUTION OF MATERIALS MANUFACTURERS ARE LISTED ON PLANS TO ESTABLISH A STANDARD. THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF IN THE OPINION OF THE TENANT, THE SUBSTITUTE MATERIAL IS OF QUALITY EQUAL TO OR BETTER THAN THE MATERIAL SPECIFIED, AND WILL SERVE WITH EQUAL EFFICIENCY AND DEPENDABILITY, FOR THE PURPOSE OF WHICH THE ITEMS SPECIFIED WERE INTENDED. SHOP DRAWINGS SHOP DRAWINGS AND CATALOG DATA ON ALL MAJOR ITEMS OF EQUIPMENT AND SYSTEMS, AND OTHER SUCH ILLUSTRATIVE MATERIAL THAT MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THIS CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND /OR CON- STRUCTION MODIFICATIONS. DRAWINGS AND SPECIFICATIONS A. THE DRAWINGS DIAGRAMMATICALLY INDICATE THE LOCATIONS OF THE VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. B. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE CONTRACTOR, TO ANY ITEMS SHOWN ON CONTRACT DRAWINGS, SHOP DRAWINGS, DESCRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL RESPONSIBILITY A. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS CONTRACT. HE SHALL PRODUCE COMPLETE AND FULLY OPERATIONAL SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS WORK, REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR INDICATED. FOR EXAMPLE, ON SINK INSTALLATIONS, ESCUTCHEONS SHALL BE PROVIDED FOR COUNTERTOP PENETRATIONS, ALTHOUGH THEY WERE NOT SPECIFICALLY IDENTIFIED IN THE CONTRACT DOCUMENTS. B. CONTRACTOR SHALL SUPPLY TO LANDLORD AND TENANT A CERTIFIED AIR BALANCE REPORT AT COMPLETION OF PROJECT. THIS SHALL BE REQUIRED FOR BOTH REMODELED AND NEW STORES. HEATING. VENTILATING AND AIR CONDITIONING A. THE WORK COVERED BY THIS SECTION OF THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE RESPECTIVE DRAWINGS, INFORMATION OR INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, ADDENDA, OR DIRECTIVES WHICH MAY BE ISSUED BY THE OWNER, SHALL BE COMPLIED WITH IN EVERY ASPECT. B. THE LISTING HEREIN OF AN ARTICLE OR MATERIAL, OPERATION OR METHOD, REQUIRES THAT THE CONTRACTOR SHALL FURNISH AND INSTALL EACH ITEM USTED, UNLESS SPECIFICALLY NOTED TO THE CONTRARY. THE CONTRACTOR SHALL PERFORM EACH OPERATION PRESCRIBED OR LISTED ACCORDING TO THE CONDITIONS STATED. EXAMINATION OF SITE ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL EXISTING CONDITIONS AFFECTING HIS WORK. ALL PROPOSALS SHALL SPECIFY, IN WRITING, ALL SUCH CONDITIONS THAT MAY ALTER OR AFFECT THE WORK UNDER THIS CONTRACT. SCOPE FURNISH ALL MATERIALS, EQUIPMENT, AND LABOR NECESSARY FOR A COMPLETE AND FULLY OPERATIONAL HEATING, VENTILATING, AND AIR CONDITIONING SYSTEM EXCEPT AS SPECIFICALLY EXCLUDED BY DRAWINGS AND /OR BY TENANT'S DIRECTIONS. EQUIPMENT A. FAN - POWERED TERMINAL UNITS: 1. CASING -- 22 -GAUGE GALVANIZED STEEL HANGER BRACKETS, SIDE ACCESS, AND FILTER WHICH IS ON THE PLENUM INLET ARE PROVIDED AS STANDARD. 2. AGENCY LISTING - THE UNIT IS UL USTED AS A ROOM AIR TERMINAL UNIT. CONTROL #9N65. ARI 880 CERTIFIED. 3. INSULATION - 1/2" MATTE -FACED INSULATION. THE INTERIOR SURFACE OF THE UNIT CASING IS ACOUSTICALLY AND THERMALLY LINED WITH 1/2", 1.75 LB /CU. FT DENSITY GLASS FIBER WITH A HIGH DENSITY FACING OF 4.0 LB /CU. FT. THE INSULATION R -VALUE IS 1.9. THE INSULATION IS UL LISTED AND MEETS NFPA -90A AND UL 181 STANDARDS. THERE ARE NO EXPOSED EDGES OF INSULATION (COMPLETE METAL ENCAPSULATION). 4. PRIMARY AIR VALVE -- AIR VALVE ROUND. THE PRIMARY AIR INLET CONNECTION IS AN 18 -GAUGE GALVANIZED STEEL CYLINDER SIZED TO FIT STANDARD ROUND DUCT. A MULTIPLE POINT, AVERAGING FLOW SENSING RING IS PROVIDED WITH BALANCING TAPS FOR MEASURING AIRFLOW. AN AIRFLOW VERSUS PRESSURE DIFFERENTIAL CAUBRATION CHART IS PROVIDED. THE DAMPER BLADE IS CONSTRUCTED OF A CLOSED -CELL FOAM SEAL THAT IS MECHANICALLY LOCKED BETWEEN 2 22 -GAUGE GALVANIZED STEEL DISKS. THE DAMPER BLADE ASSEMBLY IS CONNECTED TO A CAST ZINC SHAFT SUPPORTED BY SELF - LUBRICATING BEARINGS. THE SHAFT IS CAST WITH A DAMPER POSITION INDICATOR. THE VALVE ASSEMBLE INCLUDES A MECHANICAL STOP TO PREVENT OVER STROKING. THE MAXIMUM LEAK RATE IS 1% AT 4 W.G. INLET STATIC PRESSURE. 5. FAN MOTOR - SINGLE SPEED, DIRECT DRIVE, PERMANENT SPLIT CAPACITOR TYPE. THERMAL OVERLOAD PROTECTION PROVIDED. MOTORS WILL BE DESIGNED SPECIFICALLY FOR USE WITH AN OPEN SCR. MOTORS WILL ACCOMMODATE ANTI- BACKWARD ROTATION AT START UP. MOTOR AND FAN ASSEMBLY ARE ISOLATED FROM TERMINAL UNIT. 6. FAN SPEED CONTROL - VARIABLE SPEED CONTROL SWITCH (SCR). THE SCR SPEED CONTROL DEVICE IS PROVIDED AS STANDARD AND ALLOWS THE OPERATOR INFINITE FAN SPEED ADJUSTMENT SO THE FAN OUTPUT MAY BE MODIFIED TO ACHIEVE EXACT CFM REQUIREMENTS. 7. TRANSFORMER - THE 50 VA TRANSFORMER IS FACTORY MOUNTED IN THE FAN CONTROL BOX TO PROVIDE 24 VAC FOR CONTROLS. 8. POWER DISCONNECT - THE POWER DISCONNECT IS PROVIDED AS STANDARD AND ALLOWS THE OPERATOR TO TURN THE UNIT ON OR OFF BY TOGGLING TO THE APPROPRIATE SETTING. THIS SWITCH BREAKS BOTH LEGS OF POWER TO THE FAN AND THE ELECTRONIC CONTROLS) IF APPLICABLE). 9. OUTLET CONNECTION -- FLANGED CONNECTION. A RECTANGULAR OPENING ON THE UNIT DISCHARGE TO ACCEPT A 90' FLANGED DUCTWORK CONNECTION. 10. FILTER - A 1" FILTER IS PROVIDED ON THE PLENUM INLET AND ATTACHES TO THE UNIT WITH A FILTER FRAME. 11. ACCESS PANEL --- INTERNAL ACCESS TO UNIT IS ACHIEVED THROUGH PLENUM INLET. 12. ELECTRIC HEAT COIL - THE ELECTRIC HEATER IS FACTORY PROVIDED AND INSTALLED, UL RECOGNIZED RESISTANCE OPEN -TYPE HEATER WITH AIRFLOW SWITCH. IT ALSO CONTAINS A DISC -TYPE AUTOMATIC PILOT DUTY THERMAL PRIMARY CUTOUT, AND MANUAL RESET LOAD CARRYING THERMAL SECONDARY DEVICE. HEATER ELEMENT MATERIAL IS NICKEL - CHROMIUM. THE HEATER TERMINAL BOX IS PROVIDED WITH 7/8" KNOCKOUTS FOR CUSTOMER POWER SUPPLY. TERMINAL CONNECTIONS ARE PLATED STEEL WITH CERAMIC INSULATORS. HEATER CONTROL ACCESS IS ON THE DISCHARGE SIDE OF THE UNIT. ELECTRIC HEAT OPTIONS: A. CONTACTORS - MAGNETIC CONTACTOR. AN ELECTRIC HEATER 24 -VOLT CONTACTOR FOR USE WITH DIRECT DIGITAL CONTROL (DDC) OR ANALOG ELECTRONIC CONTROLS. B. AIRFLOW SWITCH - AN AIR PRESSURE DEVICE DESIGNED TO DISABLE THE HEATER WHEN THE SYSTEM FAN IS OFF. C. POWER FUSE - IF POWER FUSE IS CHOSEN WITH A UNIT WITH ELECTRIC HEAT, THEN A SAFETY FUSE LOCATED IN THE ELECTRIC HEATER'S LINE OF POWER TO PREVENT POWER SURGE DAMAGE TO ELECTRIC HEATER. 13. UNIT CONTROLS SEQUENCE OF OPERATION - THE UNIT CONTROLLER CONTINUOUSLY COMITORS THE ZONE TEMPERATURE AGAINST ITS SET POINT AND VARIES THE PRIMARY AIRFLOW AS REQUIRED TO MEET ZONE SET POINTS. AIRFLOW IS LIMITED BY MINIMUM AND MAXIMUM POSITION SET POINTS. FOR A PARALLEL UNIT, THE CONTROLLER WILL INTERMITTENTLY START THE FAN UPON A CALL FOR HEAT. UPON A FURTHER CALL FOR HEAT, ANY HOT WATER OR ELECTRIC HEAT ASSOCIATED WITH THE UNIT IS ENABLED. 14. ANALOG ELECTRONIC CONTROLS A. ANALOG ACTUATOR - A TRANE 3 -WIRE, 24 VAC FLOATING -POINT CONTROL ACTUATOR WITH LINKAGE RELEASE BUTTON. TORQUE IS 35 IN -LB MINIMUM AND IS NON - SPRING RETURN WITH A 90- SECOND DRIVE TIME. TRAVEL IS TERMINATED BY END STOPS AT FULLY OPENED AND CLOSED POSITIONS. AN INTEGRAL MAGNETIC CLUTCH ELIMINATES MOTOR STALL. B. ANALOG ELECTRONIC CONTROLLER - THE CONTROLLER CONSISTS OF A CIRCUIT BOARD THAT OFFERS BASIC VAV UNIT OPERATION AND ADDITIONAL OVERRIDE FUNCTIONS AND OPERATED USING 24 VAC POWER. THE CONTROLLER USED A CAPACITIVE TYPE PRESSURE TRANSDUCER TO MAINTAIN CONSISTENT AIR DELIVERY REGARDLESS OF SYSTEM PRESSURE CHANGES. THE ENCLOSURE HAS 7/8" KNOCKOUTS FOR REMOTE CONTROL WIRING. A TRANE ELECTRONIC ZONE SENSOR IS REQUIRED. C. ANALOG ELECTRONIC THERMOSTAT - THIS SINGLE - TEMPERATURE, WALL- MOUNTED ELECTRONIC DEVICE UTILIZES A THERMISTOR TO VARY THE VOLTAGE OUTPUT IN RESPONSE TO CHANGES IN THE ZONE TEMPERATURE. CONNECTIONS TO THE VAV UNIT CIRCUIT BOARD ARE MADE USING STANDARD THREE- CONDUCTOR THERMOSTAT WIRE. THE SET POINT. THE OTHER MODEL HAS AN EXTERNALLY ADJUSTABLE 2 MODELS. ONE MODEL HAS A CONCEALED, INTERNALLY ADJUSTABLE SET POINT ADJUSTMENT RANGE IS 63 -85T. THE SENSOR IS AVAILABLE IN SET POINT. C. EXHAUST FANS 1. TOILET EXHAUST FAN /LIGHT COMBINATION BY E.C. SHALL BE NUTONE #8664RP, 100 CFM © .25 S.P. WITH 4 "0 DUCT AND BACKDRAFT DAMPER 115/1/60, 3.5 SONES, 1.2 AMPS. D. ALL VAVS SHALL BE EQUIPPED WITH PROGRAMMABLE THERMOSTAT SENSOR CAPABLE OF BEING ADJUSTED TO 55'F HEATING AND 85F COOLING. DESIGN AND STANDARD CONDITIONS FOR THERMOSTAT OPERATION SHALL BE AS FOLLOWS: COOLING: 75'F MAXIMUM OCCUPIED COOLING TEMPERATURE 85'F COOLING NIGHT SETBACK. HEATING: 70'F MAXIMUM OCCUPIED HEATING TEMPERATURE 60'F HEATING NIGHT SETBACK. FAN: CONTINUOUS IN OCCUPIED AND RECOVERY MODE AND WITH HEATING OR COOLING EQUIPMENT IN UNOCCUPIED MODE. DEADBAND: CAPABLE OF MAINTAINING A 5'F DEADBAND. CLOCK: 7 DAY CAPABLE OF 7 DIFFERENT DAY SCHEDULES. OVERNIGHT: HAVE A 2 HOUR OVERRIDE ACCESSIBLE TO MANAGER. BACKUP: CAPABLE OF MAINTAINING PROGRAMMED SETTING FOR AT LEAST 10 HOURS WITHOUT POWER. DUCTWORK A. SQUARE /RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME GRADE SHEET STEEL B. ROUND DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME GRADE SHEET STEEL ALL 90 DEGREE ELBOWS FOR ROUND DUCTWORK SHALL BE FIVE (5) PIECE. ALL LONGITUDINAL SEAMS SHALL BE FORMED BY PITTSBURGH LOCKS. JOINTS SHALL BE SWAGGED WITH ONE -HALF INCH (1/2 ") OVERLAP. C. ALL SUPPLY AIR DUCTS, RETURN AIR DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED STEEL WITH 2.5" THICK (MINIMUM) .75 PCF EXTERNAL ACOUSTICAL AND THERMAL INSULATION. 1. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS; MESH AND MASTIC SEALING SYSTEMS; OR TAPES. TAPES AND MASTICS MUST BE USTED AND LABELED IN ACCORDANCE WITH UL 181A OR UL 181B. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC PRESSURES LESS THAN OR EQUAL TO 2" W.G. SHALL BE SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), MASTIC - PLUS - EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT. D. FLEXIBLE AIR DUCT FOR CONNECTIONS BETWEEN S.M. DUCT AND DIFFUSER SHALL BE AIR DUCT LISTED BY UNDERWRITERS LABORATORIES UNDER UL STANDARD 181 AS A CLASS 1 FLEXIBLE AIR DUCT AND COMPLYING WITH NFPA STANDARDS 90A AND 90B. DUCT SHALL BE FACTORY MADE AND COMPOSED OF A CPE LINER DUCT PERMANENTLY BOUNDED TO A COATED SPRING STEEL WIRE HELIX AND SUPPORTING A FIBER GLASS INSULATING BLANKET. R. -7.0 LOW PERMEABILITY OUTER VAPOR BARRIER OF FIBER GLASS REINFORCED FILM LAMINATE SHALL COMPLETE THE COMPOSITE. E. CONTRACTOR SHALL SUPPLY AND INSTALL INSECT SCREENS ON ALL DUCT OPENINGS WHICH TERMINATE OUTDOORS. INSECT SCREENS SHALL BE 10 GAUGE, ONE -HALF INCH (1/2 ") MESH IN REMOVABLE GALVANIZED STEEL FRAMES. F. ALL DUCTWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE PROCEDURES DESCRIBED IN THE LATEST EDITION OF THE AMERICAN SOCIETY OF HEATING REFRIGERATION AND AIR CONDITIONING ENGINEERS GUIDE (ASHRAE), FABRICATED AND INSTALLED IN ACCORDANCE WITH THE METHODS RECOMMENDED IN THE SHEET METAL AND AIR CON- DITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA) HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE HANGERS AND SUPPORTS A. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND LESS SHALL BE SUPPORTED BY MEANS OF BAND IRON HANGERS OF NO. 18 U.S. GAUGE ATTACHED TO DUCT BY MEANS OF RIVETS, SCREWS OR CLAMPS, AND FASTENED TO STRUCTURE ABOVE BY TOGGLE BOLTS OR OTHER MEANS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. VERTICAL DUCTS SHALL BE SUPPORTED WITH 1-1/4" x 1-1/4" x 1-1/4" ANGLES AT FLOOR PENETRATIONS. B. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND MORE SHALL BE SUPPORTED BY MEANS OF ANGLE IRON TRAPEZE HANGERS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. FLASHING A. CONTRACTOR SHALL PROVIDE WATER TIGHT 24 GA. SHEET METAL FLASHINGS AT ALL EXTERIOR WALLS AND ROOF PENETRATIONS. B. ALL CUTTING OF ROOF OPENINGS, SUPPORTS FOR ROOF OPENINGS, PITCH PANS, ROOF CURBS, FLASHINGS, COUNTER FLASHINGS, REPAIR TO ROOF, ETC. ASSOCIATED WITH HVAC SUBCONTRACTOR SHALL BE INCLUDED IN THE RESPONSIBILITY OF THE HVAC SUBCONTRACTOR. HE SHALL EMPLOY THE LANDLORD'S ROOFERS FOR THIS WORK TO MAINTAIN THE ROOF WARRANTY. DAMPERS A. SPLITTER DAMPERS SHALL BE FABRICATED OF SHEET STEEL NOT LESS THAN NO. 16 U.S. GAUGE WITH THE LEADING EDGE HEMMED. EACH DAMPER TO BE SIZED ADEQUATELY TO COVER THE SMALLER OF THE TWO OPENINGS IT CONTROLS. DAMPERS SHALL BE CONTROLLED AS FOLLOWS: EXPOSED OR ACCESSIBLE DUCTWORK - LOCKING QUADRANTS EQUAL TO YOUNG REGULATOR NO. 1 WITH DAMPER ROD END BEARINGS ON OPPOSITE END. CONCEALED DUCTWORK - LOCKING QUADRANT EQUAL TO YOUNG REGULATOR NO. 315 (CHROMIUM PLATED WITH DAMPER ROD END BEARINGS ON BOTH ENDS). B. VOLUME DAMPERS SHALL BE OF THE OPPOSED INTERLOCKING TYPE AS MANUFACTURED BY AMERICAN FOUNDRY AND FURNACES CO. (AFFCO) OR EQUAL BLADES SHALL BE OF NO. 16 GAUGE SHEET METAL AND SHALL NOT EXCEED 48" IN LENGTH OR 12" IN WIDTH. BLADES SHALL BE ON ONE -HALF INCH (1/2") DIAMETER RUSTPROOF AXLE. BEARINGS TO BE OF THE SELF-LUBRICATING FERRULE TYPE. C. FIRE DAMPERS SHALL BE SUPPLIED AND INSTALLED BY HVAC CON- TRACTOR AT DUCT PENETRATIONS IN FIRE RATED WALLS, FLOORS, CEIUNGS AND ROOF AS REQUIRED. COORDINATE WITH LANDLORD, LOCAL FIRE MARSHALL AND ALL CODES AND GOVERNING AUTHORITIES HAVING JURISDICTION. D. FIELD FABRICATED TURNING VANES SHALL BE ACCEPTABLE IN SQUARE ELBOWS. PROVIDE AND INSTALL BARBER - COLMAN AIRTURNS OR EQUAL TURNING VANES SHALL BE OF THE SAME GAUGE METAL AS THE DUCT IN WHICH THEY ARE INSTALLED. RADIUS ELBOWS SHALL HAVE A CENTER LINE RADIUS OF ONE AND ONE -HALF (1-1/2) TIMES THE DUCT WIDTH. DUCTWORK - EXCEPTIONS DUCTWORK FOR EXHAUST OR OUTSIDE SUPPLY AIR SHALL BE ALL METAL AND CONSTRUCTED ACCORDING TO RECOMMENDED PRACTICES OF THE LATEST ISSUE OF ASHRAE. SUPPORT OF DUCT SYSTEM HANGER DESIGN SHALL BE AS DESCRIBED IN THE LATEST EDITION OF THE "SMACNA" MANUAL REINFORCEMENT MEMBERS MAY BE USED TO SUPPORT DUCT SYSTEM PROVIDED DETAILS OUTLINED IN THE " SMACNA" MANUAL ARE ADHERED TO. DUCTS SHALL BE SUPPORTED AT ALL TURNS AND TRANSITIONS AND NOT MORE THAN 8' -O" O.C. STRAIGHT DUCTS UP TO 59" MAX. DIMENSIONS SHALL BE SUPPORTED 6' -O" O.C. DUCTS OVER 60" MAX. DIMENSIONS SHALL BE SUPPORTED AT 4' -0" O.C. REINFORCEMENT ALL DUCTS SHALL BE REINFORCED ACCORDING TO THE LATEST EDITION OF SMACNA MANUAL MATERIALS FOR REINFORCEMENT MEMBERS SHALL BE GALVANIZED STEEL. ALL SCREWS AND WASHERS SHALL BE PLATED OR GALVANIZED. TESTING AND ADJUSTING CONTRACTOR SHALL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW IN ACCORDANCE WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD VOLUME READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT. GUARANTEE ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND ACCEPTANCE BY TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THIS SUBCONTRACTOR WITHOUT ADDITIONAL COST TO THE TENANT. ACCESSORY ITEMS ALL MANUAL DAMPERS, FIRE DAMPERS, TURNING VANES, REGISTER CON- NECTIONS, ACCESS DOORS OR OTHER ASSOCIATED ACCESSORIES SHALL BE INSTALLED ACCORDING TO THE LATEST EDITION OF "SMACNA" MANUAL. SAP INKLER SYSTEM A. SHOP DRAWINGS -THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE TENANT'S LANDLORD AND TO THE APPROPRIATE AUTHORITIES AND INSURANCE UNDERWRITER FOR THEIR APPROVAL A COPY OF THE APPROVAL LETTER FROM THESE AUTHORITIES SHALL BE FORWARDED TO THE TENANT, LANDLORD AND DESIGN ARCHITECT. B. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: 1. STORE FRONT: CONCEALED, PAINT COVER PLATE TO MATCH CEILING 2. NON- PUBLIC AREAS WITH CEIUNGS: CHROME PEDANT 3. PUBLIC AREAS WITH CEILINGS: SEMI RECESSED, PAINT ESCUTCHEON CUP TO MATCH CEILING HANDICAP SPECIFICATIONS: ARCHITECTURAL BARRIERS ACT 42 /USC. 4-151-4157 GENERA THE WORK COVERED BY THESE SPECIFICATIONS INCLUDES BUT IS NOT LIMITED TO PROVIDING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLY WITH REQUIREMENTS OF THIS FACILITY. PLUMBING FIXTURES A. OLSONITE SEAT (STANDARD) 1/2" C.W. SUPPLY AND 4" PLANS ENTED WASTE. WATER CLOSET (BARRIER FREE , - AS IDENTIFIED ON PLANS ELONGATED WATER SAVER CADET 18" HIGH WITH OLSONITE #95 CLOSET SEAT 1/2" C.W. SUPPLY AND 4" VENTED WASTE. HEIGHT OF WATER CLOSET SEAT SHALL BE 17" MIN. & 19" MAX. FORCE REQUIRED TO ACTIVATE FLUSH VALVE LEVER TO BE 5 LBS. MAXIMUM B. LAVATORY - AS IDENTIFIED ON PLANS WITH SINGLE CONTROL LEVER FAUCET, 1/2" C.W. AND W.W. SUPPLY AND 1-1/2" VENTED WASTE. INSULATED WITH EXPOSED LATED WATER "A P UMBEREX" (OR EQUAL) PIPE LAVATORY COVERS. BE FAUCET CONTROLS SHALL BE OF THE TYPE NOT REQUIRING TIGHT GRASPING, PINCHING, OR TWISTING OF WRIST AND AN OPERATING FORCE NOT EXCEEDING 5 LBS. SELF - CLOSING VALVES SHALL BE OF THE TYPE REMAINING OPEN FOR AT LEAST 10 SECONDS. C. CLEANOUTS - SHALL BE AS MANUFACTURED BY JOSAM, ZURN, OR EQUAL, AND SHALL BE INSTALLED AT ALL BENDS, ANGLES, AND ENDS OF ALL WASTE AND SEWER LINES, AS CALLED FOR ON THE DRAWINGS AND AS REQUIRED BY LOCAL CODES. ALL CLEANOUTS SHALL BE FLUSH WITH FINISHED FLOOR TO GRADE, AND IN ALL CASES, SHALL BE PROVIDED WITH SUFFICIENT SPACE FOR RODDING. D. FLOOR DRAIN - AS IDENTIFIED ON PLANS. CAST IRON DRAIN WITH NICKEL - BRONZE ADJUSTABLE STRAINER; INSIDE CAULK. OUTLET AND CLAMPING DEVICE WHERE REQUIRED. PROVIDE WITH TRAP PRIMER TAP AND TRAP PRIMER WHERE INDICATED. E. WATER HEATER - MANUFACTURER AS IDENTIFIED ON PLANS. REFER TO PLUMBING DRAWING TO DETERMINE IF NEW WATER HEATER IS A TANK TYPE OR IS OF THE INSTANTANEOUS VARIETY. PROVIDE R -10 INSULATION UNDER TANK. NOTE: OWNER'S GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION OF ALL TOILET ACCESSORIES INCLUDING MATERIALS A. SANITARY SEWER - CAST IRON OR COPPER PIPING MAY BE USED EXCEPT THAT ALL PIPING BELOW GRADE SHALL BE CAST IRON. VENTS TWO INCHES (2 ") IN SIZE AND SMALLER MAY BE EITHER SCHEDULE 40 GALVANIZED STEEL OR COPPER PIPING. B. DOMESTIC WATER AND HOT WATER PIPING TO BE COPPER TYPE "L" INSULATED WITH ARMAFLEX OR EQUIVALENT INSULATING TO A THICKNESS OF 1". C. GAS PIPING (WHEN REQUIRED) SHALL BE BLACK STEEL SCHEDULE 40 WITH SCREWED FITTINGS. PIP' RC A. PIPING AND FITTINGS SHALL BE OF THE WEIGHTS AND TYPES SHOWN ON DRAWINGS. SIZES SHOWN ON ON DRAWINGS ARE NOMINAL PIPE SIZES. B. ALL PIPING SHALL BE INSTALLED PARALLEL TO, OR AT RIGHT ANGLES WITH THE BUILDING WALLS AND PARTITIONS AND SHALL BE INSTALLED WITH THE PROPER PITCH. C. ALL PIPING SHALL BE UPENDED AND POUNDED TO REMOVE ANY FOREIGNER PRESENT AND SHALL BE SWABBED IF NECESSARY. PREPARING PIPE A. SCREWED PIPE SHALL BE INSTALLED WITH PIPE COMPOUND APPLIED TO THE MALE THREAD WITH NOT MORE THAN TWO THREADS LEFT EXPOSED. PIPE SHALL BE REAMED AFTER THREADING. B. BELOW GRADE SANITARY PIPING SHALL BE CAST IRON PIPE AND SHALL BE INSTALLED WITH ONE THIRD OF THE HUB CAULKED WITH FIRST QUALITY OAKUM, AND THE REMAINDER FILLED WITH FIRST QUALITY CAULKING AT ONE POURING AND CAULKED TIGHT. C. COPPER JOINTS SHALL BE MADE UP WITH 95 -5 SOLDER. HANGERS AND SUPPORTS HORIZONTAL PIPING SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED 10' -0" WITH SWIVEL SPLIT PIPE HANGERS EQUAL TO CRANE #199F OR GRINNELL #104. VERTICAL PIPING SHALL BE SUPPORTED BY MEANS OF WROUGHT IRON CLAMPS SUSPENDED FROM THE UNDER- SIDE OF STRUCTURE WITH HANGER RODS. VALVES ALL VALVES SHALL BE BRASS AND MANUFACTURED BY CRANE, NIBCO, STOCKHAM, LUNKENHEIMER, NORDSTROM, GRINNELL OR EQUAL ROUGH -INS FOR SECOND LEVEL STORES, THE GENERAL CONTRACTOR SHALL ROUTE ALL LINES REQUIRED FOR PLUMBING ROUGH-INS TIGHT AGAINST THE UNDERSIDE OF THE SECOND FLOOR LEVEL WITH ALLOWANCE FOR SLOPE. SECOND FLOOR SLAB SHALL BE CORE DRILLED AS REQUIRED TO INSTALL THESE ITEMS AT THE LOCATIONS SHOWN ON THE PLANS. COORDINATE WITH LOWER LEVEL TENANTS. TESTING AND ADJUSTING CONTRACTOR SHALL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW IN ACCORDANCE WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD VOLUME READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT. OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. C. HVAC SYSTEM CONTROL MAINTENANCE AND CAUBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD- DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. ALL PIPING SHALL WITHSTAND AIR PRESSURE TESTING PER GOVERNING PLUMBING CODE. GUARANTEE ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED PLUMBING SYSTEM SHALL BE FULLY OPERATIONAL AND ACCEPTANCE BY TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THIS SUBCONTRACTOR WITHOUT ADDITIONAL COST TO THE TENANT. MECHANICAL TEMPORARY SERVICES THE CONTRACTOR SHALL PROVIDE THE FOLLOWING SPECIFIC ITEMS: A. TELEPHONE - THE TENANT'S GENERAL CONTRACTOR SHALL INSTALL JOB SITE TELEPHONE AND NOTIFY TENANT AS LISTED ON PLANS OF THE TELEPHONE NUMBER AND NAME OF THE SUPERINTENDENT. B. TEMPORARY WATER - WATER REQUIRED IN THE PERFORMANCE OF CONTRACT SHALL BE PROVIDED AND PAID FOR BY THE CONTRACTOR. WATER USED FOR HUMAN CONSUMPTION SHALL CONFORM TO REQ- UIREMENTS OF STATE AND LOCAL AUTHORITIES FOR POTABLE WATER. C. TEMPORARY ELECTRICITY - TEMPORARY ELECTRIC SERVICE REQUIRED IN THE PERFORMANCE OF THE CONTRACT SHALL BE FURNISHED AND PAID FOR BY THE CONTRACTOR WHO SHALL FURNISH, INSTALL, AND MAINTAIN ALL TEMPORARY OVERHEAD CONSTRUCTION, METERS, DROPS, AND OTHER WIRING AND FITTINGS FOR BOTH LIGHT AND POWER AT LOCATIONS REQUIRED IN THE WORK AND SHALL BEAR THE COST OF MAKING THE SERVICE CONNECTIONS. BEFORE FINAL ACCEPTANCE, TEMPORARY ELECTRICAL SERVICE FACILITIES INSTALLED BY THE CONTRACTOR SHALL BE REMOVED AND THE SERVICE CONNECTIONS DISABLED IN AN ACCEPTABLE MANNER. D. TEMPORARY HEAT - WHEN REQUIRED FOR PROPER INSTALLATION AND /OR PROTECTION OF ANY PORTION OF THE WORK, THE CON- TRACTOR SHALL FURNISH AND INSTALL TEMPORARY HEATING UNITS AS APPROVED BY LANDLORD OR LOCAL AUTHORITY. E. COST OF LANDLORD PROVIDED UTILITY SERVICES - IF LANDLORD ELECTS TO PROVIDE TEMPORARY UTILITY SERVICES, THE CONTRACTOR WILL BE SO INFORMED BY THE TENANT. THE CONTRACTOR SHALL MAKE PROVISIONS OR COORDINATE WITH LANDLORD'S GENERAL CONTRACTOR TO PAY THE COST OF TEMPORARY CONSTRUCTION AND UTILITY SERVICES. NOTE FOR GENERAL CONTRACTOR IT IS THE RESPONSIBILITY' OF THE TENANT'S GENERAL CONTRACTOR TO MAKE USE OF APPLICABLE NOTES AND SPECIFICATIONS LISTED ON THIS SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB. Mom t3 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 19 2007 City Of Tukwila BUILD NG Di " IO j JUN - 8 2007 PERMIT CENTEh