HomeMy WebLinkAboutPermit M07-145 - VACANT SPACEVACANT SPACE 1105 ANDOVER PK W M07 -145 Parcel No.: 3523049110 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: BRETT IRWIN Address: PO BOX 19252 , SEATTLE WA Contractor: Name: IECS INC. Address: P.O. BOX 19252 , SEATTLE, WA Contractor License No: IECS * * *044QL DESCRIPTION OF WORK: REPLACE 5 -TON SPLIT SYSTEM HEAT PUMP WITH A LIKE KIND SYSTEM. Value of Mechanical: $14,950.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10 /06 City..if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1105 ANDOVER PK W TUKW VACANT SPACE 1105 ANDOVER PK W , TUKWILA WA MECHANICAL PERMIT AMB PROPERTY CORP 60 STATE ST STE 1200 C/0 RE TAX , BOSTON MA Fees Collected: $327.20 International Mechanical Code Edition: 2003 EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 623 -1651 Phone: 206 939 -9495 Expiration Date: 11/20/2008 M07 -145 07/05/2007 01/01/2008 Boiler Compressor: 0-3 HP /100,000 BTU 1 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -145 Printed: 07 -05 -2007 Permit Center Authorized Signature: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ice- Permit Number: M07 -145 Issue Date: 07/05/2007 Permit Expires On: 01/01/2008 Date: / - _0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: 74 Date: Print Name: X E L) / ! ^ Se . , / a Ge This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 - 145 Printed: 07 -05 -2007 Parcel No.: 3523049110 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila VACANT SPACE Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1105 ANDOVER PK W TUKW PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: M07 -145 ISSUED 06/28/2007 07/05/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M07 - 145 Printed: 07 -05 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: /< J 16/1 doc: Cond -10/06 /e-,-,_ ,51,1„04,.-_, Date: 7 �-s/d7 M07 -145 Printed: 07 -05 -2007 Property Owners Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://rtwwatulcwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 7' - 2. -- L l t O Site Address: //AC Suite Number: 029 Tenant Name: , New Tenant. Ilr Yes El ..No Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: Contact Person: E -Mail Address: Q:\Applications\Fonns- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No.` Mechanical Permit No. a ~ ' Plumcbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) City CONTACT PERSON - who do we contact when your permit is ready to be issued State Floor: Zip Name: Day Telephone: ../.06 .2 - 9'/09 Mailing Address: - �- &7C City ` State Zip E -Mail Address: �4T -ttx Number: (°t s , 5W 9 �9� 9/oa GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip State City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Page 1 of 6 State Zip Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty r / Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM / Incinerator - Comm/Ind MECHANICAL PERMIT INFORMATION - 206- 431 -3670 MECHANICAL CONTRACTOR IN ORMATION Company Name: �O �v c k_ • ZIA. Mailing Address: D • `. Contact Person: of LL�Q E -Mail Address: Contractor Registration Number: . S3f # O4QLr Valuation of Mechanical work (contractor's bid price): $ / 9 950 y .� Scope of Work (please.provide detailed ,information): q. 4 - /e. Fuel Type: Electric ❑ Gas ....0 Other: Q: Applications\Fotms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bit Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... Indicate type of mechanical work being installed and the quantity below: City State Zip Day Telephone: 4 4zff - /4-57 Fax Number: oZ:.5 Expiration Date: ..to x40$, -a- _ _4,, Page 4 of 6 t Data Application Accepted: � 1 1 21 101- Date Application Expires: . I 1 Staff Initials Irritp ul a i w a.ru °,... , Fii "I t F7 1 AIl" pq � xtar h 1 ip 11 P fal 7S 1 m : ;B�IIGI I rn � ul I l „n � ,. 1 I ' l! 1 p t ", s a , `� I 9 i` i I; a °� >-� one _ I d _ : i7�'M�:�x,5S�k"J�'`�'`"'h�,"'•n �� � r r �(' �OLu�ttC�a�GrO°'1� IG I.�r...a{�4`!�. . h t:�r rPr�."�' ��y1,R•�I`- 1 r'�I�d�L����QMJ�1,� �.w� ��Mr'� '�4`.. �IL �' JMK7W�w+F.1 .f'..N MI!1!15NIw .'•�L :.t.. il:.�.i17;1. [L�: BUILDING 0 Signature: Q,uppiicusoos1Fmmc- Apptleadanaoa Llaeu.2aob. Permit Appliodanake Raba 5.2005 Ws OR AUTHORIZED AGENT: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review —Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time Car additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 1053.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding ISO days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 62 // 4/0 - 7 Print Name: r` a 11 '� 'J . MC.Day Telephone: . ( — a 57 " O g6 s Mailing Address: (2 "7 '2—t0 �.. ,, _ �,� u ` , L , a ` ..� �. _ .. . _ strut: f T Zip Page 6 of 6 Parcel No.: Address: Suite No: Applicant: Initials: SB User ID: Payee: ACCOUNT ITEM LIST: Description VACANT SPACE Receipt No.: R07 -01736 1670 IECS, INC. TRANSACTION LIST: Type Method Description Payment Check 39700 MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3523049110 1105 ANDOVER PK W TUKW Account Code 000/322.100 RECEIPT Permit Number: Status: Applied Date: Issue Date: Payment Amount: 358.00 Payment Date: 08/20/2007 09:48 AM Balance: 60.00 Amount 58.00 Current Pmts 58.00 Total: $58.00 M07 -145 ISSUED 06/28/2007 07/05/2007 1798 08/20 9710 TOTAL 58.00 doc: Receiot -06 Printed: 08-20 -2007 Parcel No.: 3523049110 Address: 1105 ANDOVER PK W TUICW Suite No: Applicant: VACANT SPACE Receipt No.: R07 -01237 Initials: JEM User ID: 1165 Payee: IECS, INC. ACCOUNT ITEM LIST: Description dart: Rec'. int -OR MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 39284 327.20 Account Code Current Pmts 000/322.100 267.76 000/345.830 59.44 Total: $327.20 Permit Number: M07 -145 Status: PENDING Applied Date: 06/28/2007 Issue Date: Payment Amount: $327.20 Payment Date: 06/28/2007 10:27 AM Balance: $0.00 9799 06/28 9716 TOTAL 327.20 Printari OR- 2R -2ff7 Project: !� l i .il Type of Inspection: / ,I(/f;' // /i 3Xr / 4 S Ad ress: S Date CC ailed: al Instructions: — Sp //a Date Wanted: a• � �� Requeste Phone N `' -fi(� 2 l sS- 5 F I INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 63 00 S ou t h ce nter Blvd. #100, Tukwila, WA 98188 I /w-- PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. v , El $58.0' ' EINSPECTION EE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: j/,e7(,mi+ -- S Type ofjnspection: f-/ it, A / required prior to approval. Address: // t7 S 4 / /6cA/c R /D /C ct_J Date Called: Special Instructions: Date gted: Requester: �, . Phone No: x-06 — _ -/56a • pproved per applicable codes. Corrections required prior to approval. CAM ' NTS: #2 � ii 4 ... � �, . L i i A i i--- � / /�31 (.40-4:2 et 4 e- k- � - / :j / - AKIO ..r . • �_ Areem Ak / / - / /...e/ Li I.• __'_! . , INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3€70 Inspector: Date:by i $513.00 PECTIOk EE OUR ED. Prior to inspection, fee must be aid at 6300 Southcenter Bl ., Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: Project: / 3 /7( ' / �1 Type of InApectio% / 7 U / a / v Address: //o5 4NLJJv� - P Pe Date Called: Lt Special Instructions: Date Wanted (7 / (9 i: Requester: Phone No: INSPECTION RECORD k , f �� 5 Retain a copy with permit INSPECTI O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 COMMENTS: c(;)-ied ❑ Approved per applicable codes. Corrections required prior to approval. ❑ $58.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 1 Receipt No.: Date: Project: `/w -4/ Spillir Type of Inspection: n 17- h - / i Address: / /() �" /In1JGyQ Pit Date Called: ',J Special Instructions: Date Waved: a Requester: Phone No: 026 - 2 � "- .. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. Corrections required prior to approval. / COMMENTS: /yY77 $58.dO REINSPECTION F EQUIR D. Prior to inspection. fee must be paid at 6300 Southcenter lvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: se. 4IF Project: _ v f7��f� I �/ Ty of I pection: �- 7 "'� , - /ri n/dN /,5-7-- Address_, 4/0 l/eI Date Called: Special Instructions: Date Want d: a.m_ Requester: Phon No: J - 2 S t ;(' Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 /72Q 7 PER (206)431 -367 COMMENTS: Corrections required prior to approval. .. Ai II - $58.00 ' SPECTION FEE R UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: n // ion: d /1 ' 7 /A,i„ D ate Called: Special Instructions: Date W�nied: . O ( ) I / ,)n4 Cv ,_ Requester: Phone No: � - 255 /3 2 (/4// / S<, /ice 7 - /1/,'/Y, - <v - . j2/ /A- 5'.J�,� a �J n1 1 ld /1& le) ,,v / `' ✓ / "A Project: l/' (i,)..✓7's ,)170 e Type of Inspection: n // ion: Address: //0 S / 17v( v ('i /',e 4v D ate Called: Special Instructions: Date W�nied: . O a ITr Requester: Phone No: � - 255 /3 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. Inspe • ceipt No.: J .00 REINSPECTION F REQUI D. Prior to inspection, fee must be aid at 6300 Southcente lvd.. ite 100. Call the schedule reinspection. 'Date: Project: r /1/7 v, Type o Inspecn: ti �j � % " ��/7 ii i'2.)/.,e<, : Address: Date Called: Special Instructions: Date Wanted: a.m. 7 ti-b Requester: Phone N : ' 26/— Z- 55— ?.c INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit (20 •)431 -3670 12 Corrections required prior to approval. COMMENTS: Z/14-' j 0 /1 'i1(f ,� Fl 7 r' rL (� // 4 /U e ? 7 A., x ) /7- 10 /0 r' 74,4 . 1 6r ✓,0 9 Inspect I Date: .00 REINSPECTION F E REQUIRED nor to inspection, fee must be d at 6300 Southcenter lvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: 1105 Andover Park West Tukwila, WA. 98168 Women's Restroom Air Hanc ler — P Men's SEPARATE REQUIRED FOR: oMechanical +dam ',Plumbin VG 6 ROM City of Tukwila BUILDING" VISIOP T 0 [zi Warehouse - r Restroom Thermostat Return Air Supply Air DUCT LAYOUT N® d%anges shall be made to the scope cf work without prior approval of Tukwila Building Dlvis *on. i:rv:: :ons will require a new plan submittal c ._i r.._ y i, c :uca cdditlonal plan review fees. FILE Permit No. W N E .EV` li y PWv CODE COMPt. Ng— JUL - 3 2007 Plan review epproval Is subject to : . and AprrovzI cf c.^zction . .. does not atithodza the vio :zt'c- c: c-y cc ep'e d Glide cc calloance. RIB of app; c, ci ; : _: J c , end c nd tlons Is acknowledged: Date: , 7/5/V7 City of TUkwlta BUILDING DON RECEIVED CITY OF TUKWILA JUN 2 8 2007 1 PERMIT CENTER 1105 Andover Park West Tukwila, WA. 98168 Floor Plan Space #1105 Suite #294 Elevations Ground to Roof Top: 32' Floor to Top of Office Wall: 9' To pf Office Wall to Roof Deck: 19' Ground to Floor Level: 4' Warehouse Offices Space 1109 W N S E Air handler unit will be installed above the restrooms in the N.E. comer of the Building and supported by 4 "x6" beams. The condenser will be located directly above the air handler on the rooftop. The condenser weight is 299 lbs. Total building length is 1/5 of a mile. REViEWE FOR CODE COMPLIANCE AP:' ' wC JUL - 3 2007 s'+. ,2- • • ON GRADE DOOR £DOO( LEVEL DOOR ■RAIL LEVEL DOOR Accu Tech Suite 1109 12,000 sf On Site Contact: Adam Lassiter (206) 575-2820 AMB UPLAND DISTRIBUTION CENTER _ 1105 -1121 ANDOVER PARK WEST — TUKWILA, WASHINGTON Banwer Transfer Suite 1111 18,000 sf On Site Contact: Pete Armendariz (206) 762 -1283 0 50' 100' 200' m AN! a ,.n. Comatorm Loci minor to *tat two nd 294 Building Address Ranges 1105 -1121 .- Mitchell Moving Suite 1113 12,000 sf On Site Contact: Don Kostonich 206 - 575 -8623 • Eagle Global Logistics Suite 1105 18,000 sf Contact: Property Management; Tenant using for dead storage LEGEND �p AVAILABLE WAREHOUSE AND OFFICE dO - CI rt. w o V ` • 0 N —J Mitchell Moving Suite 1115 24,000 sf On Site Contact: Mike c. Sansaco Home Furnishings Suite 1121 18,000 sf On Site Contact: Larry Whse Supv (206) 575 -0811 Hours: M, T, Th, F -10 -8 W - closed Sat - 10-6 Sun - 11-5 • The four (4) AhvIB Upland Distribution Center Buildings are nestled behind the Sonthcenter'Iheatre (theatre located at the intersection of S.180 Street and Southcenter Boulevard). There .are three (3) c rivcs that envelope these bulldiaga all off From. Andover Park West; Triland Drive, Mtdland Drive, and Upland Drive. Driving Directions: AMB UPLAND DISTRIBUTION CENTER Address Ranges: 305 — 351 Andover Park West & 1105 --1139 Andover Park West From 180th Street heading east, turn north onto Andover Park West: Ell just a short distance, tura west onto Midland Driv (This is the center drive to the property.). C't v Less than % of a mile down the drive is a landscape planter; you are 3110W at the property. . 0 , 1.... c There are two buildings on - the south of this plantr.x and two buildings to the. north. .....i N • Tenants with address ranges 1105 — 1139 Andover ParkWest are la the buildings to the scill awl C . Tenants with address ranges 305 — 351 .Andover ParkWest are in the buildings to the n el L...., , AV i- LEGEND ON GRADE DOOR ADOOK LEVEL DOOR • • Andover Park West t ..Ai, ' AAANAWFAIAliAlmaniumm. +M xMe 0w01011NMNnh AnOttlxxIrxxx «NlthNtle4tAtinAknONAHOWNON4H041 - i ./ % - - --- • . . • � pp AVAILABLE WAREHOUSE AND OFFICE 68,s F AA aau LA AA u Ho f tT u u a AA U 25HCA3 ComfortTM' Series 13 Heat Pump with Puron® Refrigerant Sizes 18 To 60 1 -1 /2 To 5 Noninal Tons Puron_ Me environmentally sound netrgeranl Product Data A04030 Comfort SERIES Carrier's heat pumps with Puron ® refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCA has been designed utilizing Carrier's Puron refrigerant. The environmentally sound refrigerant allows consumers to make a responsible decision in the protection of the earth's ozone layer. As an Energy Star® Partner, Carrier Corporation has determined that this product meets the Energy Star® guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Star® guidelines. Turn to the Experts. FILE COPY Permit No. INDUS IM„L,,.EADING ,_ FEAT LS BENEFITS Efficiench2 '. • 13C3E.R/ 10.1 - 10.8 EER/ 7.7 - 8.3 HSPF (Nominal) • Microtube Technology refrigeration system • Indoor air quality accessories available Sound L • Sound level as low as 74 dBA Comfort • System supports Thermidistat'" or standard thermostat controls Reliability • Puron® refrigerant - environmentally sound, won't deplete the ozone layer and low lifetime service cost. • Front- seating service valves n.7 C71;2 • Scroll compressor • Internal pressure relief val • Internal thermal overload • High pressure switch • Loss of charge switch • Filter drier • Balanced refrigeration system for max Durability WeatherArmor'" protection package: • Solid, durable sheet metal con rkrert tfii • Steel louver coil guard • Color matched, ceramic coated cabinet screws • Baked -on, complete coverage, powder paint Applications • Longline - up to 250 ft. total equivalent length, up to 200 ft. condenser above evaporator, or up to 80 ft. evaporator above condenser (See Longline Guide for more information.) • Low ambient (down to -20 °F) with accessory kit RECEIVED CITY OF TUKWILP JUN 2 8 , ?O(? PERMIT CENTER Warranty Single -Phase • 10 year limited compressor warranty • 5 year limited parts warranty Three -Phase • 5 year limited compressor warranty • 1 year limited parts warranty Mok 14C Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X 13 SEER X X X X X X X Scroll Compressor X X X X X X X Louvered Coil Guard X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Suction Line Accumulator X X X X X X X High Pressure Switch X X X X X X X Loss of Charge Switch X X X X X X X 1 2 3 4 5 6 7 8 9 10 11 12 13 N N A A NN N N N NN NN NN N N 2 5 H C A 3 3 6 A 0 0 3 0 Product Product Series Family Tier 25 = HP H = RES HP C= Comfort A = Puron 3 =13 SEER Puron. Ore environmentally sound refrigerant MODEL NUMBER NOMENCLATURE Major Series SEER ARI Stanoerd 2' 1290 Unitary Air Conditioners Cooling Capacity STANDARD FEATURES 2 Variations Open Open Voltage 3= 208/230 -1 A = Standard 0 =Not 0 =Not 5= 208/230 -3 Defined Defined 6 =460 -3 ISO 9001:2000 A an Energy Star® Partner, Carrier Ct rporalion has determined that this product meets the ENERGY STAR® guidelines for energy effcicncy. Refer to the combination ratings in Product Data for system combinations that meet Energy Star guidelines. Minor Series 0, 1, 2... UNIT SIZE - SERIES 18 -30 24-30 30-30, 50 36 -30, 50, 60 42 -30, 50, 60 48 -30, 50, 60 60 -30, 50, 60 Operating Weight (lb) 158 183 226 231 263 283 299 Shipping Weight (Ib) 181 210 258 263 295 313 331 Compressor Type Scroll REFRIGERANT Puron® (R -410A) Control TXV (Puron Hard Shutoff) Charge (lb) I. 7.65 I 8.4 I 11.75 I 12.35 COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty. (CFM) 2196 2614 2614 3365 3810 4046 4046 Motor HP 1/10 1/10 1/10 O a — O N 1/5 1/5 1/5 1/5 Motor RPM 1100 800 800 800 800 800 800 COND COIL Face Area (Sq. ft.) 13.13 15.09 25.87 25.87 25.15 20.12 22.63 Fins per In. 25 20 20 20 20 20 20 Rows 1 1 1 1 1 2 2 Circuits 4 5 6 6 6 8 8 VALVE CONNECT. (In. ID) Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (n. OD) Vapor (0 -80 ft. Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1 -1/8 Liquid (0 -80 ft. Tube Length) 3/8 drff Acceptable Cooling Capacity Loss ( %)Total Equivalent Line Length (ft.) Unit Nominal Size (Btuh) Vapor eters Llne Standard Application Long L ne Application Requires Accessories Diam (In. OD) 25 80+ 150 175 200 225 250 18000 1/2 1 r . 3 ..: 7 / ! » l/✓ 5 f 1 - Stage Puron HP 5/8 0 0 `., 1 ", '.' ' <;. iii i „4.,. ; � .' .... /,.. 24000 5/8 0 1 t3 » g /r 1 -Stage Puron HP 3/4 0 0 �; # �� �/) v, ;. i 5/8 1 2 3 30000 1-Stage Puron HP 3/4 0 0 1 1 -: -° t [' 2 2 i f -- -' 7/8 1, l..! ?.a ' i, , . <. ;.:, %., 5/8 ° ,6 � 7 / 9 3, ,�1 6' ”) 36000 1 -Stage Puron HP — 3/4 ��, �� �j G! ' %i i i i 7/8 42000 3/4 1 -Stage Puron HP 7/8 0 0 1 a :., 1' :° 2 2 2 3 3 48000 3/4 0 1 2 2 ,; 5. 5 6 7 8 1 -Stage Puron HP 7/8 0 0 1 i �, s - 2 2 3 3 4 3/4 1 2 4 4 5 6 7' 9 10 11 12 60000 7/8 0 1 2 2 2 3 4 4' 5 5 6 1 -Stage Puron HP 1 1/8 0 0 0 0 1 1 2 N O 0 S v r CV t7 N �fG C1 t, 0.- 0 0 0 O N O O O a — O N OC9- iL did PH DATA * For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical erential, consu Note: See unit Installation Instruction for proper installation. LONG LINE APPLICATION: An application is considered "Long line" when the total equivalent tubing length exceeds 80 ft. or when there is more than 20 ft. vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft The maximum vertica sep ar a tion is 200 ft. when outdoor unit VAPOR LINE SIZING AND COOLING CAPACITY LOSS PURON 1 —STAGE HEAT PUMP APPLICATIONS is above indoor unit, and 80 ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Long -Line Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss. Standard Length 80 f or l ess total equivalen • ' eng th aide Applications in this area ate'long line A are required as w s low n recomrt en led ire Application Guidelines Appliionsin this area may have height restriction th s at limit alloable t equivalent length, when outdoor unit is below indoor cat unit Long Line Application Guidelines 3 ORDER NUMBER DESCRIPTION 18 -30 24 -30 30 -30 30 -50 36 -30 36 -50 36 -60 42 -30 42 -50 42 -60 48 -30 48 -50 48 -60 60 -30 60-50 60 -60 KAACH1201AAA CRANKCASE HTR TSTATXXSBP01 Backplate for Standard Programmable Thermostat TSTATXXBBP01 Backplate for Builder's Thermostat TSTATXXCNV1ot Thermostat Conversion Kit (4 to 5 Wire) —10 Pack X X S S S S KAACH1301AAA CRANKCASE HTR X S S KAACH1401AAA CRANKCASE HTR X X X X X X KAACH1501AAA CRANKCASE HTR X KAAFTO101AAA FREEZE THERMOSTAT X X X X X X X X X X X X X X X X KSAHS1701AAA HARD START (CAP /RELAY) X X X X X X X KHAIR0101AAA ISOLATION RELAY X X X X X X X X X X X X X X X X KSALA0301410 LOW AMBIENT PSW X X X X X X X X X X X X X X X X HC34GE239 MOTOR FAN BALL BEARING X HC34GE242 MOTOR FAN BALL BEARING X X X HC38GE228 MOTOR FAN BALL BEARING X X HC40GE228 MOTOR FAN BALL BEARING X X X X X X KSALA0601AAA MOTORMASTER 230V X X X X X X X X X X X X KSALA0701AAA MOTORMASTER 460V X X X X KHAOT0201 SEC OUTDOOR THERMOSTAT X X X X X X X X X X X X X X X X KHAOT0301 FST OUTDOOR THERMOSTAT X X X X X X X X X X X X X X X X KHALSO401 LLS SOLENOID VALVE X X X X X X X X X X X X X X X X KAACS0201 PTC START ASSIST PTC X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X X X X X X X X X X KAATD0101TDR TIME DELAY X X X X X X X X X X X X X X X X KSATX0201PUR TXV PURON HSO X X X X KSATX0301 PUR TXV PURON HSO X X X X X X KSATX0401PUR TXV PURON HSO X X X KSATX0501PUR TXV PURON HSO X X I X THERMOSTAT / SUBBASE PKG. DESCRIPTION TSTATCCPRHO1 —B* Thermidistat °. Control — Non — Programmable /Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) TSTATCCPHHO1 —B* Hybrid Heat (Dual Fuel) Thermostat — Auto Changeover, 7 —Day Programmable, °F / °C, Includes Outdoor Sensor (TSTATXXSEN01 —B) TSTATCCPHPO1 — B Thermostat — Auto Changeover, 7 — Day Programmable, °F / °C, 2 — Stage Heat. 1 — Stage Cool TSTATCCNHP01 —C Thermostat — Auto Changeover, Non — Programmable, °F / °C, 2 —Stage Heat, 1 —Stage Cool TSTATCCSHPO1 Standard Programmable Thermostat — Manual Changeover, 5 -2 Day Programmable, °F / °C, 1 —Stage Heat/ 1 —Stage Cool TSTATCCBHPO1 —B* Builder's Thermostat — Heat Pump, Non — Programmable, °F / °C, 2 —Stage Heat, 1 —Stage Cool, Manual Changeover TSTATXXSEN01 —B ** Outdoor Air Temperature Sensor TSTATXXNBP01 Backplate for Non — Programmable Thermostat TSTATXXPBP01 Backplate for Programmable Thermostat and Thermidistat " Control TSTATXXSBP01 Backplate for Standard Programmable Thermostat TSTATXXBBP01 Backplate for Builder's Thermostat TSTATXXCNV1ot Thermostat Conversion Kit (4 to 5 Wire) —10 Pack ACCESSORIES x = Accessory S = Stender ACCESSORY THERMOSTATS * Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non — programmable air conditioner version and builders thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat. t Thermostat conversion kit is a 24 —vac accessory that can turn a 4 —wire thermostat application into a 5 —wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat. 4 ACCESSORY REQUIRED FOR LOW- AMBIENT COOLING APPLICATIONS (Below 55° REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 Ft.) REQUIRED FOR SEA COAST NS APPLICATIONS (Within 2 miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Accumulator Standard Standard Standard Compressor Start Assist Capacitor and Relay Yes Yes No Motor Master Control or Low- ambient Pressure Switch Yes No No Support Feet Recommended No Recommended Liquid Line Solenoid Valve No See Long - Line Ap plication Guideline No Ball Bearing Fan Motor Yest No No ACCESSORY USAGE GUIDELINE * For tubing line sets between 80 and 200 ft. and /or 20 ft. vertical differential, refer to Residential Spit- System Long line Application Guideline. t Required for Low - Ambient Controller (full modula ion feature) and MotorMaster Control only. Accessory Description and Usage (Listed Alphabetically) 1. Ball- Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMaster® is used. 2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single -phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Compressor Start Assist — PTC Type Solid state electrical device which gives a "soft" boost to the compressor at each start-up. Usage Guideline: Suggested in installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 5. Evaporator Freeze Thermostat An SPST temperature - actuated switch that stops unit operation when evaporator reaches freeze -up conditions. Usage Guideline: Required when low ambient kit has been added. 5 6. Isolation Relay An SPDT relay which switches the low- ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. Usage Guideline: Required in all heat pumps where low ambient kit has been added. 7. Liquid -Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. Usage Guideline: An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline. 8. Low- Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low- ambient temperatures down to 0 °F when properly installed. Usage Guideline: A Low- Ambient Pressure Switch or MotorMaster® Low- Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55 °F (12.8 °C). 9. MotorMaster® Low- Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20 °F (- 28.9 °C), it maintains condensing temperature at 100 °F «10 °F (37.8 °C - 12 °C). Usage Guideline: A MotorMaster® Low Ambient Controller or Low- Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55 ° F (12.8 °C). Suggested for all commercial applications. Accessory Description and Usage (Listed Alphabetically) 10. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Carrier thermostats listed in this publication. II. Outdoor Thermostat An SPDT temperature - actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user- selected set point. Usage Guideline: Electric supplemental heat applications in non - variable speed indoor units when electric heat staging is desired. 12. Secondary Outdoor Thermostat An SPDT temperature- actuated switch which turns on third -stage of supplemental electric heaters when outdoor air temperature drops below the second -stage set point. Usage Guideline: Outdoor thermostat applications where electric heater is capable of 3 -stage operation. - CONTINUED 13. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA. Usage Guideline: Suggested when unit is installed closer than 15 ft. to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft. apart. 14. Thermostatic Expansion Valve (TXV) Bi -Flow A modulating flow- control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Usage Guideline: Accessory required to meet ARI rating and system reliability, where indoor not equipped. Required in all heat pump applications designed with Puron refrigerant. 15. Time -Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: Accessory required to meet ARI rating, where indoor not equipped. 6 UNIT SIZE V /PH OPER VOLTS* COMPR FAN MCA MIN WIRE SIZEt MIN WIRE SIZEt MAX LENGTH (FT)$ MAX LENGTH (FT)t MAX FUSE ** or CKT BRK AMPS MAX MIN LRA RLA FLA 60° C 75° C 60° C 75° C 18 -30 208/230/1 253 197 48 9.0 0.75 12 14 14 66 62 20 24 -30 58.3 12.8 0.7 16.7 14 14 47 45 25 30 -30 77 14.1 0.7 21.3 12 12 59 56 30 36 -30 79 16.7 1.2 22 12 12 57 54 35 42 -30 109 19.9 1.2 26 10 10 77 73 40 48 -30 117 21.8 1.2 35.4 8 8 88 84 50 60 -30 134 26.3 1.2 34.1 8 8 91 87 50 30 -50 208/230/3 253 197 71 10.8 0.7 14.2 14 14 64 61 20 36- 50 88 11.3 1.2 15.3 12 12 94 90 25 42 -50 88 13.5 1.2 18.0 10 10 128 122 30 48 -50 83.1 17.2 1.2 22.7 8 10 158 97 35 60 -50 110 17.0 1.2 22.5 8 10 160 98 35 36 -60 460/3 506 414 38 5.8 0.6 7.8 14 14 233 222 15 42 -60 46 7.1 0.5 9.3 14 14 196 186 15 48 -60 41 7.5 0.6 10.0 14 14 182 173 15 60 -60 52 7.8 0.6 10.3 14 14 177 168 15 UNIT SIZE STANDARD RATING TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) 125 250 500 1000 2000 4000 8000 18 -30 74 52.5 60.5 68.0 68.5 64.5 60.0 54.0 24 -30 74 54.5 63.0 66.5 66.0 64.0 60.5 51.5 30 -30, 50 74 53.0 60.5 66.0 67.5 64.5 61.5 53.0 36 -30, 50, 60 74 55.0 62.5 67.0 70.5 62.5 60.0 52.5 42 -30, 50, 60 74 55.0 60.0 64.0 67.5 61.5 60.0 55.0 48 -30, 50.60 74 57.5 64.5 67.5 69.5 66.5 61.0 53.0 60 -30, 50, 60 74 53.5 63.0 67.5 70.0 63.5 60.0 55.5 UNIT SIZE - SERIES REQUIRED SUBCOOLING ( °F) 18 -30 10 24 -30 12 30 -30,50 11 36 -30, 50, 60 10 42 -30, 50, 60 11 48 -30, 50, 60 11 60 -30, 50, 60 12 ELECTRICAL DATA * Permissible limits of the voltage range at which the unrt will operate satisfactorily t If wire is applied at ambient greater than 30° C (86° F), consult table 310 -16 of the NEC (ANSI /NFPA 70). The ampacity of non - metallic - sheathed cable (NM), trade name ROMEX, shall be that of 60° C (140° F) conditions, per the NEC (ANSI /NFPA 70) Article 336 -26. If other than uncoated (no- plated), 60 or 75° C (140 or 167° C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI /NFPA 70). $ Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time -Delay fuse. FLA - Full Load Amps LRA - Locked Rotor Amps MCA - Minimum Circuit Amps RLA - Rated Load Amps NOTE: Control circuit is 24 -V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors /compressors contain internal overload protection. A- WEIGHTED SOUND LEVEL (DBA) CHARGING SUBCOOLING (TXV -TYPE EXPANSION DEVICE) 7 UNIT SERIES ELECTRICAL CHARACTERISTICS A B C D E F G H J K L M N P 25HCA318 0 X 0 0 0 25 3/4" 31 13/16" 3 3/4" 5/8" 4 7/16" 21 1/4" 9 1/8" 1 1/8" 3 13/16" 2 13/16" 1/2" 10 1/4" 10 3/4" 14" 25HCA324 0 X 0 0 0 31 3/16" 28 15/16" 3 3/4" 5 /8" 6 9/16" 24 11/16" 9 1/8" 1 1/8" 3 13/16" 2 13/16" 1/2" 15 5/8" 16 3/4" 14 1/2" 25HCA330 0 X 0 X 0 313/16" 4515/16" 33/4" 3/4" 69/16" 2411/16" 91/8" 1 1/8" 313/16" 213/16" 1/2" 201/4" 17 3/8" 18 3/4" 25HCA336 0 X 0 X X 31 3/16" 4515/16" 33/4" 3/4" 69/16" 2411/16" 91/8" 11/8" 313/16" 213/16" 1/2" 17" 143/4" 20 3/8" 25HCA342 0 X 0 X X 35" 39 1/8" 3 7/8" 7/8" 6 9/16" 28 7/16" 9 1/8" 1 1/8" 3 13/16" 2 15/16" 5/8" 17 1/4" 19 1/8" 15 3/4" 25HCA348 0 X 0 X X 35" 32 5/16" 37/8" 7/8" 6 9/16" 287/16" 91/8" 11 /8" 313/16" 2 15/16" 5/8" 19" 19" 14 1/2" 25HCA360 0 X 0 X X 35" 391/8" 37/8" 7/8" 6 9/16" 287/16" 91/8" 11/8" 3 13/16" 2 15/16" 5/8" 19" 19" 19" UNIT SIZE MINIMUM MOUNTING PAD DIMENSIONS 18 26" X 26" 24, 30, 36, 42 31 1/2" X 31 1/2" 48, 60 35" X 35" DIMENSIONS B FIELD CONTROL SUPPLY CONN. 07/8" HOLE FIELD FOVEA SUPPLY CONN. g 1/8" HOLE WITH 01 1 /8" KNOCKOUT 03/8" LIQUID LINE CONN. C 00 VAPOR LINE CONN. Aso. X =YES 0 = NO AIR DISCHARGE I11111I1111 111111 IIII IIIIIIIIIIIII P AIR INS G AIR IN 1. Allow 30" clearance to service side of unit, 48" above unit, 6" on one side, 12" on remaining side, and 24" between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 °F, max. 125° F 3. Series designation is the 13th position of the unit model number. 4. Center of gravity S. AIR IN AIR DISCHARGE 03/8" TIEDOWN KNOCKOUTS Ill PLACES 25HCA3 AIR IN 40 30 20 10 0 -10 0 10 25HCA BALANCE POINT WORKSHEET 20 30 OUTDOOR TEMPERATURE, 1 F 40 50 25HCA3 60 70 80 23.4 20.5 17.6 14.6 - 11.7 - 8.8 - 5.9 2.9 0.0 A1151111) I 1 l J I I 1.1.1AN14NAI Ilt II 1111 /II II II III t I I I I I 1 ■ I I 1 ■ 1 • • r 511CA3 lliA FYJANIIIIJV � l..... I.YJANI,N' t 1 1 1 I I r 1 1 -1 — \ \ 1111 1111 /111 1111 1 - 1 `I'- -1 - I- I - I - I - - I - I - I 1111 1111 t /11 1111 ' l t — I'1" i r T 1 '1'1'1 - i 1 i - I - 1' 1 1111 1 111 III 1 1 •11 —1��1'ft7__I_ _ _ _ 1 I I 1 - 1 I I I I I I 1 1 1 1 1 1 1 I I I r los list 1111 II 1111 11,3 1 1 — 1'1' T l 'I - I I - 1 i ; - I 1'I I I 11 I 11 1 I I 1 I I \ \\ \111 111 111 J _I _ 1111 1111 1 1 1 1111 /III 11 1111 1111 1111 1111 I II 1111 I I I - 2511CA33lr:1 12 sucnlw:\ II) JAN I11. 1p 231I 1 II) 1AN111.J , NI]J:\ -1 - - i •�111'AIIMA I.1 J: \NI111x — � I - 1 1 I I I I I I I I I I I I L 1 I I r _ ♦_�__1__ti_ _ J _ J _ _ _ _ l _ I 1 I r - - .I__I_.I I-_ _ J _ I _ _ I _ _ L _ - 1 _ .1- 1 _ _ I _ _a- _I____I -_ - _ J -- I _ _ I _ _ L _ 1 _ -1 _ -1- _ _ _ r _ _H__I__I__4_ _ -1 _1 -- 1 _ _ L _ 1 _ _ _ I _ I _ _�__I__I- I I I _ r _ _ _�____r__ L I _ r _ _ I I 1 1 _ r _ r _ _ - I._�____1__I__(I; l L I _ _ I _ _ 1 _ - II I I I I I I I ■ __ BASED ONINN()(IRI NI'.AIIt AI',II.I AND AI' N \TI:I) Ai I t I I 1 1 I 1 1 1 Il I 1 40 30 20 10 0 -10 0 10 25HCA BALANCE POINT WORKSHEET 20 30 OUTDOOR TEMPERATURE, 1 F 40 50 25HCA3 60 70 80 23.4 20.5 17.6 14.6 - 11.7 - 8.8 - 5.9 2.9 0.0 A1151111) Unit Size - Series Indoor Model Cooling Ca aci P ty ARI Standard Rat ngs Cooling Heating Furnace Model Factory Enhance Standard Rating SEER TDR EER High Temp Low Temp E Capac- ity E COP H Capac- ity H COP HSPF 18 - 30 *FY4ANF018 17,100 TDR &TXV 13.00 10.50 18,000 3.36 10,900 2.24 7.7 FE4ANFOO2 17,700 TDR &TXV 14.50 12.00 17,200 3.64 10,500 2.48 8.2 FF1ENP018 17,100 TDR &TXV 13.00 10.50 18,000 3.38 10,900 2.26 7.7 FF1ENP024 17,400 TDR &TXV 13.20 10.70 17,900 3.44 10,900 2.28 7.7 FV4BNFOO2 17,700 TDR &TXV 14.50 12.00 17,200 3.64 10,500 2.48 8.2 FX4CNF018 17,500 TDR &TXV 14.50 11.70 17,600 3.60 10,500 2.38 8.0 . FX4CNF024 17,700 TDR &TXV 15.00 12.00 17,400 3.66 10,500 2.42 8.1 FY4ANF024 17,200 TDR &TXV 13.00 10.50 17,900 3.38 11,000 2.26 7.7 CAP * *1814A ** 17,000 TDR &TXV 14.50 11.70 17,100 3.34 10,200 2.30 7.7 58CV(A,X)070 -12 CAP * *1814A ** 17,000 TXV 13.00 10.50 18,000 3.32 10,900 2.24 I 7.7 CAP * *2414A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.50 10,300 2.36 7.8 58CV(A,X)070 -12 CAP * *2414A ** 17,400 TXV 13.00 10.80 18,000 3.48 11,000 2.30 I 7.7 CAP * *2417A ** 17,400 TDR &TXV 15.00 12.00 17,200 3.54 10,300 2.38 7.8 58CV(A,X)090 -16 CAP * *2417A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.52 10,300 2.36 7.9 58MVB060 -14 CAP * *2417A ** 17,400 TXV 13.00 10.80 18,000 3.48 11,000 2.30 7.7 CNPF *2418A ** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 I 7.8 CNPH *2417A ** 17,300 TDR &TXV 14.50 11.70 17,200 3.54 10,300 2.38 7.8 58CV(A,X)070 -12 CNPH *2417A ** 17,400 TDR &TXV 14.50 11.70 17,200 3.58 10,300 2.38 7.9 58CV(A,X)090 -16 CNPH *2417A ** 17,300 TDR &TXV I 14.50 11.70 17,300 3.56 10,300 2.38 7.9 58MVB040 -14 CNPH *2417A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.58 10,300 2.38 I 7.9 58MVB060 -14 CNPH *2417A ** 17,400 TDR &TXV 14.50 11.70 17,300 3.58 10,300 2.38 7.9 58MVB080 -14 CNPH *2417A ** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8 CNPV *1814A ** 17,000 TDR &TXV 14.50 11.70 17,100 3.48 10,300 2.34 I 7.7 58CV(A,X)070 -12 CNPV *1814A ** 17,000 TXV 13.00 10.80 18,000 3.48 10,900 2.28 7.7 CNPV *2414A ** 17,300 TDR &TXV I 14.50 11.70 17,300 3.54 10,300 2.38 7.8 58CV(A,X)070 -12 CNPV *2414A ** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8 CNPV *2417A ** 17,400 TDR &TXV 14.50 11.70 17,200 3.60 10,300 2.38 7.9 58CV(A,X)090 -16 CNPV *2417A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.56 10,300 2.38 7.9 58MVB060 -14 CNPV*2417A** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 j 7.8 CSPH *2412A ** 17,300 TDR &TXV 14.50 11.70 17,200 3.56 10,300 2.38 7.9 58CV(A,X)070 -12 CSPH *2412A ** 17,400 TDR &TXV 15.00 12.00 17,200 3.58 10,300 2.38 7.9 58CV(A,X)090 -16 CSPH *2412A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.58 10,300 2.38 7.9 58MVB040 -14 CSPH *2412A ** 17,300 TDR &TXV 15.00 12.00 17,300 3.58 10,300 2.38 7.9 58MVB060 -14 CSPH *2412A ** 17,300 TDR &TXV 14.50 11.70 17,300 3.58 10,400 2.38 7.9 58MVB080 -14 CSPH *2412A ** 17,400 TXV 13.00 10.80 17,800 3.50 11,000 2.32 7.8 24 -30 *FY4ANF024 22,600 TDR &TXV 13.00 10.5 24,000 3.54 15,000 2.48 8.2 FE4ANFOO2 23,200 TDR &TXV 14.50 11.70 23,200 3.78 14,300 2.64 8.5 FE4ANF003 23,400 TDR &TXV 15.00 12.00 23,000 3.76 14,200 2.66 8.5 FFIENP024 22,800 TDR &TXV 13.00 10.70 24,000 3.56 15,200 2.46 8.2 FF1ENP030 22,800 TDR &TXV 13.00 10.40 24,200 3.56 15,100 2.48 8.0 FV4BNF002 23,200 TDR &TXV 14.50 11.70 23,200 3.80 14,400 2.66 8.5 FV4BNF003 23,400 TDR &TXV 14.50 12.00 23,000 3.78 14,300 2.66 8.5 FX4CNF024 23,000 TDR &TXV 14.00 11.40 23,800 3.72 14,600 2.60 8.3 FX4CNF030 23,400 TDR &TXV 14.50 11.70 23,600 3.84 14,600 2.66 8.5 FY4ANF030 23,000 TDR &TXV 13.20 10.60 24,000 3.64 15,100 2.52 8.4 CAP * *2414A ** 22,600 TDR &TXV 14.00 11.50 23,400 3.62 14,300 2.58 8.3 58CV(A,X)070 -12 CAP * *2414A ** 22,800 TXV 13.00 10.50 24,400 3.60 15,100 2.50 8.3 CAP * *2417A ** 22,800 TDR &TXV 14.50 11.70 23,400 3.66 14,300 2.60 8.4 58CV(A,X)090 -16 CAP * *2417A ** 22,800 TDR &TXV 14.50 11.70 23,400 3.64 14,300 2.58 8.4 58MVB060 -14 CAP * *2417A ** 22,800 TXV 13.00 10.50 24,400 3.60 15,100 2.50 8.3 CAP * *3014A ** 23,000 TDR &TXV 14.50 11.70 23,000 3.64 14,400 2.60 8.4 58CV(A,X)070 -12 CAP * *3014A ** 23,000 TXV 13.00 10.60 23,400 3.56 15,200 2.52 8.3 CAP * *3017A ** 23,000 TDR &TXV 14.50 11.70 23,000 3.68 14,300 2.62 8.5 58CV(A,X)090 -16 CAP * *3017A ** 23,000 TDR &TXV 14.50 11.70 23,000 3.68 14,300 2.62 8.5 58MVB060 -14 CAP * *3017A ** 23,000 TXV 13.00 10.60 23,400 3.56 15,200 2.52 8.3 CNPF *2418A ** 22,800 TXV 13.00 10.50 24,400 3.68 15,200 2.52 8.5 COMBINATION RATINGS e notes on pg. 17 10 ACTIVITY NUMBER: M07 -145 DATE: 06 -28 -07 PROJECT NAME: VACANT SPACE SITE ADDRESS: 1105 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: r I Buil g Division Public Works Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY �- PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ TUES/THURS ROUTING: Please Route Ef Structural Review Required REVIEWER'S INITIALS: ❑ Permit Coordinator DUE DATE: 07-03-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DATE: Planning Division DUE DATE: 07 -31-07 Approved with Conditions Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License IECS * * *044QL Licensee Name IECS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601639846 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 19252 Address 2 City SEATTLE County KING State WA Zip 981091252 Phone 2064694153 Status ACTIVE Specialty 1 AIR CONDITIONING Specialty 2 UNUSED Effective Date 11/13/1996 Expiration Date 11/20/2008 Suspend Date Separation Date Parent Company Previous License Next License SEATTMI038NR Associated License Business Owner Information Name Role Effective Date Expiration Date HUMPHREY, GEORGE 01/01/1980 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information No Matching Information Savings Information Savings Bank Name Bank Branch Location Assignment of Savings Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date https:// fortress .wa.gov /Ini/bbip /printer.aspx ?License= IECS * * *044QL 07/03/2007