HomeMy WebLinkAboutPermit M07-157 - JAMBA JUICEJAMBA JUICE
17100 SOUTHCENTER PY
STE 104
M07.157
Parcel No.: 2623049081
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
17100 SOUTHCENTER PY TUKW
WIG PROPERTIES LLC -SS
4811 134Th PL SE , BELLEVUE WA
Contact Person:
Name: BRENT ADKISSON
Address: 2020 S 320 ST #C -90 , FEDERAL WAY WA
Contractor:
Name: D15 MECHANICAL
Address: 2020 S 320 ST #C -90 , FEDERAL WAY WA
Contractor License No: D 15MEM *930BT
DESCRIPTION OF WORK:
SHELL ONLY: INSTALL (2) EACH 5 TON HVAC UNITS
Value of Mechanical: $10,000.00
Type of Fire Protection:
JAMBA JUICE
17100 SOUTHCENTER PY, STE 104 , TUKWILA WA
Furnace: <100K BTU
>100R BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
doc: IMC-10 /06
Cityf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
MECHANICAL PERMIT
EOUIPMENT TYP AND OUANTITY
0 Boiler Compressor:
0 0-3 HP /100,000 BTU 0
O 3 -15 HP /500,000 BTU 0
0 15 HP /1,000,000 BTU.. 0
0 30 -50 HP /1,750,000 BTU.. 0
O 50+ HP /1,750,000 BTU 0
2 Fire Damper 0
0 Diffuser 0
0 Thermostat 2
0 Wood/Gas Stove 0
0 Water Heater 0
0 Emergency Generator 0
0 Other Mechanical Equipment 0
0
* *continued on next page **
M07 -157
Permit Number: M07 -157
Issue Date: 08/03/2007
Permit Expires On: 01/30/2008
Phone:
Phone: 360 888 -5433
Phone: 360 888 -5433
Expiration Date: 01/30/2009
Fees Collected: $269.58
International Mechanical Code Edition: 2006
Printed: 08 -03 -2007
Permit Center Authorized Signature:
doc: IMC-10 /06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
vdt,.
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this pe • 't does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the p rman e of wo , : I • autho ' - • to sign and obtain this mechanical permit.
Signature: ,r Date:
Print Name: .GJ /'` f-1 , 4 t' le i ` xr-t -k
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspendec
or abandoned for a period of 180 days from the last inspection.
Permit Number: M07 -157
Issue Date: 08/03/2007
Permit Expires On: 01/30/2008
Date: P-3-67
M07 -157 Printed: 08 -03 -2007
PERMIT CONDITIONS
1: ** *BUILDING DEPARTMENT CONDITIONS * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 2623049081 Permit Number: M07 -157
Address: 17100 SOUTHCENTER PY TUKW Status: ISSUED
Suite No: Applied Date: 07/20/2007
Tenant: JAMBA JUICE Issue Date: 08/03/2007
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
6: Readily accessible access to roof mounted equipment is required.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
8: Manufacturers installation instructions shall be available on the job site at the time of inspection.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206 - 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The attached set of fire alarm plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
15: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and
the Tukwila Fire Department job Number available to confirm shut down approval. (City Ordinance #2051)
doc: Cond -10/06
M07 -157 Printed: 08-03 -2007
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
16: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
17: Fire alarm systems shall be maintained in an operative condition at all times. Fire alarm systems and their component
parts shall be inspected and tested per manufacturer's specifications and N.F.P.A. 72 at a minimum frequency of every
twelve months. A copy of inspection, test and maintenance records shall be forwarded to the Tukwila Fire Prevention
Bureau. (NFPA 72 (10.2.1.1)) (City Ordinance #2051)
18: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this
project.
19: Local U.L. central station supervision is required. (City Ordinance #2051)
20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
21: These plans were reviewed by Inspector 515. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond - 10/06
* *continued on next page **
M07 -157 Printed: 08-03 -2007
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the perf 1 ance of work.
Signature:
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Print Name: A 7_ //d/c1
Date:
M07 -157 Printed: 08-03 -2007
Name: ,>2 f'.✓T /�d /lr�S�
Mailing Address:
E -Mail Address:
Company Name:
Mailing Address:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
w t r yr i CIA rriu•s
Community DevelopmenL- Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://wwwatukwila.wa.us
Q:UpplicationsWorms- Applications On Line \3-2006 - Mechanical Permit Application.doc
Revised: 4 -2006
bh
Mechanical No.
Project No "' O
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: I / dCo ' SO u C e t / V /( ttl Y Suite Number: /0 (/ Floor:
Tenant Name: TT4b 0• z - ) e -e
Property Owners Name: tU I' ►rope_iff`e s L L C -35 /
Mailing Address: h/ &'// SE / 3y 7 fl 9e t�e vtne
CONTACT PERSON who do we contact when your permit is ready to be issue
2715 1Nieckc+,..; ceJ
2.0 7c, Sr 30T • Sf X1=90
gi, f ter- Adkt SSw
Contact Person:
E -Mail Address:
Contractor Registration Number: D/5 Meti `73o 6T
King Co Assessor's Tax No.: — 10Z.
City
Day Telephone: Lz t -gr S /33a
City
Fax Number:
Expiration Date:
For ofce use only),
New Tenant: E,.... Yes D ..No
u
State
State
,l006
Zip
Zip
city d e ✓ecA L ia
State / (
Day Telephone: 764) 8g8 5 933
Fax Number:
/
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Recur
State
Zip
City
Day Telephone:
Fax Number:
ENGINEER OF RECORD = All plans must be wet stamped by Engineer; of Record
State
Zip
City
Day Telephone:
Fax Number:
Page 1 of 2
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace<100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Fumace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
2
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
Other Mechanical
Equipment
Valuation of Project (contractor's bid price): $ (0 / OCO
Scope of Work (please provide detailed information): ‘ SHE � L ONLY ' t
Z �( 2 E4 S 1 r //U/fr t lei *5
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... ►:/ Replacement .... ❑
Fuel Type: Electric ❑ Gas ... . Other:
Indicate type of mechanical work being installed and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER
Signature:
I Date Application Accepted:
AUTHS,.' DAGENT:
Print Name: R Cit/T /401550t,..
Q:1 Applications\Forms- Applications On Linel3 -2006 - Mechanical Permit Application. doe
Revised: 4 -2006
bh
Date: 7 -26 -0 /
Day Telephone:
Mailing Address: Z 2. C) St 3 7o77' SI Feder "- w' ? cx3
City State Zip
Date Application Expires:
ot17,9
Page 2 of 2
Project:
Type of Inspection:
P t4 f
\..)
Address:
Date Called:
Special Instructions:
Date Wanted:
/7 I i3 iks7
•
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT 0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- 6
4;0 per applicable codes. El Corrections required prior to approval.
COMMENTS:
\
'Receipt No.:
Date:
$ .00 REINSP CTION FE REQUIRED. P ior to inspection, fee must be
d at 6300 Southcenter Blvd.. Suite 1001 Call the schedule reinspection.
'Date:
Pipj ct:
Type of Inspection:
Address: s�.O 0 S'Atille Wei F3t4
e Called:
Special Instructions:
Date Want d: a,
1��1 (a
Requester:
P . n ( 3 Uses -( 1,3 -
CITY OF TUKWILA BUILDING DIVISION R'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -36
COMMENTS:
/-
Inspect
INSPECTION NO.
R ceipt No.:
INSPECTION RECORD
Retain a copy with permit
roved per applicable codes. ❑ Corrections required prior to approval.
Z
Date:
/ //34-2
Date:
PERMIT NO.
� .00 REINSPECTION FE REQUIRE Prior to inspection, fee must be
id at 6300 Southcenter Blvd.. Suite 00. Call the schedule reinspection.
Project:
Typ of Inspection:
Address:
Date Called:
Special Instructions:
Date Want d:
t Z �1 3 / tT - )
C 1
(C 11:141
r r
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
/ 71 0 7.'-6)
INSPECTION NO. PEWIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206
OMMENTS:
Insp • • r:
Approved per applicable codes. 0 Corrections required prior to approval.
Date:
1211 3/d
c] $58. I ' EINSPECTION FEE R QUIRED. Pri to inspection, fee must be
pai . 6300 Southcenter Blvd., Suite 100. ll the schedule reinspection.
'Receipt No.:
'Date:
Payee: BRENT ADKISSON
TRANSACTION LIST:
Type Method Description
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049081 Permit Number: M07 -157
Address: 17100 SOUTHCENTER PY TUKW Status: APPROVED
Suite No: Applied Date: 07/20/2007
Applicant: JAMBA JUICE Issue Date:
Receipt No.: R07 -01598 Payment Amount: $221.66
Initials: WER Payment Date: 08/03/2007 03:07 PM
User ID: 1655 Balance: $0.00
Amount
Payment Cash 221.66
Account Code Current Pmts
000/322.100 221.66
Total: $221.66
doc: Receiot -06 Printed: 08 -03 -2007
RECEIPT NO: R07 -01447
Payee: BRENT ADKISSON
SET TRANSACTIONS: .
Set Member Amount
M07 -156 59.44
M07 -157 47.92
M07 -158 47.92
M07 -159 47.92
M07 -160 82.49
TOTAL: 285.69
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www ci. tukwila. wa. us
SET RECEIPT
Initials: JEM Payment Date: 07/20/2007
User ID: 1165 Total Payment: 285.69
SET ID: 0720 SET NAME: D 15 MECHANICAL
TRANSACTION LIST:
Type Method Description Amount
Payment Cash 285.69
TOTAL: 285.69
Account Code Current Pmts
000/345.830
TOTAL:
285.69
285.69
0587 017/23 9710 TOTAL
295 .9
12 -11 -2007
BRENT ADKISSON
2020 S 320 ST #C-90
FEDERAL WAY WA 98003
RE: Permit No. M07 -157
17100 SOUTHCENTER PY TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the
Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does
allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests
must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from
being taken.
In the event you do not call for the above inspection and receive an extension prior to 01/30/2008 , your permit will become null and
void and any further work on the project will require a new permit application and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
er Marshall
Permit Technician
xc: Permit File No. M07 -157
Cizy of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
• eht 4
+ - 1*
+ 4 '
- -
+
t-
Ran review approval Is subject b errors and omissions.
Approval cf cor.stuction documents does not authorize
the vidat:n c? accepted code or ordinance. Receipt
d apprcvci ._7 cnd condliorm is edam
By
+ 4- •
I4
b
RECEIVED
CITY OF TUKWILA
JUL 2 0 ?IV
PER MIT CENTER
.... .... n s.. , ..• ....... '.7 --..saKas......
REVIEWED rOR
CODE COMPLIOICE
PPROIRID
<
(2 Au
Ow Of Tulwila
BUILDING DIVISIQL
0
0
LL
z
C.9
z
0
4 \e)
2
CO g
1
CT
E N G I N E E R I N G
PLLC
FILE COPY
Pe -!": No.
STRUCTURA LCULATIONS
.: .
t
For HVAC Roc Top Units
Jamba Juice
North Building @ Southcenter Square
Tukwila, WA
Structural Engineers
EXPIRES: 7/27
RECEIVED
CITY PF TI JKWILA
JUL 2 0 7007
- EnMi'i CENTER
180 Nickerson St.
Suite 302
Seattle, WA
98109
(206)285-4512(V)
(206) 285 -0618(F)
ta,%(...S7 ‘ .A ■•
,ML)
-E,
two
2 EA. FLUTE
TO TOP FLANGI
— -
36G 66 I
6-2.3
0 RTU
tt4
2 EA. FLUTE
TO TOP FLANG
4
OF
VAN
RE:
LEA
M-2.•
OPP
- 1 6 0 19›.--
CT
e . •
ENGINEERING
Project:
Structural Engineers
PLLC
•••
Suite 302
■ Seattle, WA
98109
QAC • Date:
(206) 285-4512
FAX:
Client: Page Number: (206) 285-0618
1-kE E...\N - 11\ -- E. L.x) OF - 114 : L. - Rj - L) ,
Nz E LCT IT TL ip 1-TaLAA. ca ac*JL.t.
S. TUB 1::)t–f-. Si 1
Pk%) tlOC \‘•\!tild.t tc4. 1UC T T r
r:
F - C -1.2 - • Ti" r FOC/ E T \J L Lo A
\r 7- ' 7 5 c-5 \ 1 (ASr..E.. 1- cavz:)
1 RZ a- : '' °
F .4-,..--2,.. %e-,,, Vc,1 •
k \ k
1 )1 1 V 1 T 9 7 ----- --- - - - ,
/ , ,LA.
OSitc - a- ,:-._ \
F -.:- Az \r\1 cr2 . - 7 C, iz 0 , e‘ -1, • T.. \^1 ,
7 k
.7,
F i m ''--...____ \ -
4 ' . . - Z ' q ' / °\ '''■ 7 1° ;. 7S (,:?--) ) - Z.Z.
/ ' e...trelL
St...111\1(.1 — T c_rarE\A! Th
CL .) ail I c-..? c.s.:RS:\e•I . C
. m mArk t "RE: 5
it
,•)`-ef — Ptcs).
r2. 5ce.ez.A-7
2.2_rn ( 4 rS
160( o00
oco ( — \cxD 00
+7" \ko L..L ( :) . 7 CD\OZTi.
FILE COPY
DESCRIPTION Pe rrn!t No.
YORK Sunline 2000 units arirbonvertible single package air
conditioners with a common binet and a common roof curb
for the 3,4,5 and 6 ton sizes. The units were designed for light
commercial and commercial applications. They can easily be
installed on a roof curb, slab, roof jack or frame.
All units are self- contained and assembled on rigid full
perimeter base rails with fork lift slots on three sides and holes
for overhead rigging. Every unit is completely piped, wired,
charged and tested at the factory to provide for a quick and
easy field installation.
The units are available in cooling only, and cooling with gas heat
Electric heaters are available as field - installed accessories.
The cabinet is constructed of galvanized steel, painted with long
lasting, durable, and aesthetically pleasing power paint Paint
finish meets 750 hour salt spray tests perASTM -8117 standards.
All models include a 5 -year limited warranty on scroll
compressors and electric heating elements, a 10 -year limited
warranty on gas -fired heat exchangers and a 1 -year limited
warranty on all replacement parts.
FEATURES
COMMON FOOTPRINT/COMMON CABINET - All model
sizes and configurations share a common cabinet and a
common roof curb. The installer has the flexibility of setting one
curb and placing the proper tonnage unit on that curb after the
internal load has been determined. He can even decide
between gas or electric heat after the curb has been set
HIGH EFFICIENCY - All units have a high cooling efficiency,
and gas / electric models have a minimum AFUE of 80 %. All
efficiencies exceed legislated minimum levels and provide low
operating costs.
CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom
duct openings are covered when they leave the factory. If a side
supply / side return is desired, you simply remove the two side
duct covers from the outside of the unit and discard them.P'RCE
bottom supply / bottom return is desired, you simply reere r- j
•�
Jr\
JUL 2 0 'n r q
r .,,.l. t c.i'i I 'd
YORK®
SINGLE PACKAGE
AIR - COOLED
AIR CONDITIONERS
530.18 -TOW (500)
D4CE 036, 048, 060 & D2CE 072
D7CG 036, 048, 060 & D2CG 072
3, 4 AND 5 NOMINAL TONS $91918111110 135 , evS
AND 6 NOMINAL TONS (9 EER) ?' 24000
SUNLINE 2OOOTMi Tiobtt I4 -i AA
two knockoutpane!s fromtiitse of the unit and discard them.
No panel cutting or s rapping js required! Convertible airf
design allows maximum field &cibility and minimum inventory.
Economizers may be , used Oct either bottom and side duct
applications with no modifications required.
FACTORY - INSTALLED OPTIONS - Economizers can be
installed at the factory. The economizers are shipped installed
and wired. Only the rain hood needs to be field assembled and
installed. Field labor dollars can be saved by having the
components arrive already installed.
Adjustable belt drive blowers are available on all models from
the factory for complete airflow flexibility.
FIELD - INSTALLED ACCESSORIES - Accessories were
designed for quick and easy installation. The motorized damper
and economizers simply slide in, and electrical connections are
made by modular plugs. Electric heaters mount easily, and
knockouts are provided in the internal partitions to connect the
elements to the control box single point kit.
The motorized air damper includes a slid - in/plug -in damper
assembly with a rainhood and filters. The outdoor air dampers
open when the indoor fan motor is energized. The damper is
capable of providing 0% through 100% of outdoor return air
opening.
The manual outdoor damper provides 0% through 35% or 0%
through 100% of return air opening (field adjustable). Designed
for duct mounted side or bottom supply /return applications.
Includes rain hood assembly and fitter.
The 14" high roof curb is shipped knocked down. An insulated
deck is not required because the bottom of the unit is insulated.
Low ambient controls are available to provide stable unit
operation at outdoor temperatures down to 0°F.
Propane, high attitude and low NOx kits are also available to
cover all gas heating applications.
RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5-ton
itArate over a wide range of design conditions with a
Contd.
MO* 61
MODEL
ARI RATINGS
NOMINAL
ELECTRIC HEAT CAPACITY
STANDARD
COOL
NG CAPACITY
SOUND
(dbels)
MBH
SEER
EER
240V
480V
600V
DCE036
36.0
10.00
9.10
82
5 7,10,
15 &20
7,10,
15 &20
10,
15 &20
1.300
DCE048
47.4
10.00
9.00
82
5 7, 10,
15 &20
7,10,
15 &20
10,
15 &20
1.700
DCE060
59.0
10.00
9.10
82
5, 7, 10,
15,20 &30
7,10, 15
20 &30
10, 15,
20 &30
2.100
DCE072
72.0
-
9.00
84
5, 7,10,
15.20 &30
7,10,15,
20 & 30
10,15
20 & 30
2.400
MODEL
ARI RATINGS 1
GAS HEAT CAPACITY
STANDARD
CFM
COOLING CAPACITY
80/67-95°F
SOUND
RATING
(dbels)
INPUT
(MBH)
OUTPUT
(MBH)
AFUE
(%)
S.S.E.
(%)
TEMP.
RISE
(°F)
GAS
LINE SIZE
(in. OD)
MBH
SEER
EER
DCG036N040
DCG036N079
36.0
36.0
10.00
10.00
9.10
9.10
82
82
50
100
40
79
80.9
80.5
81.6
80.8
15-45
40-70
1/2
1
1.300
DCG048N060
DCG048N099
47.4
47.4
10.00
10.00
9.00
9.00
82
82
75
125
59
99
80.9
80.3
81.6
80.6
25-55
45-75
1/
1 h
1.700
DCGO6ON079
DCGO6ON099
59.0
59.0
10.00
10.00
9.10
9.10
82
82
100
125
79
99
80.5
80.3
80.8
80.6
25-55
35-65
th
1 /2
2.100
DCG072N079
72.0
-
9.00
84
100
79
80.5
80.8
25-55
1/2
54
DCG072N099
72.0
-
9.00
84
125
99
80.3
80.6
35-65
ih
2.400
SOUND POWER RATINGS FOR SUPPLY AIR BLOWER
MODEL
CFM
ESP
BLOWER
SOUND POWER (dB 10-12 watts)
OCTAVE BAND CENTERLINE FREQUENCY (Hz)
SWL
dB (A)
dB (A)
10 '
IWG
SPEED
KW
63
125
250
500
1,000
2,000
4,000
8,000
036
1,200
0.60
LOW
0.60
84
84
74
67
69
62
57
52
74
41
048
1,600
0.55
HIGH
0.80
85
85
75
68
70
63
58
53
75
42
060
2,000
0.45
HIGH
1.00
86
86
76
69
71
64
59
54
76
43
072
2,200
0.30
HIGH
1.35
87
87
77
70
72
65
60
55
77
44
PHYSICAL DATA - BASIC UNITS
MODEL
EVAPORATOR
BLOWER
EVAPORATOR
COIL
COMPRESSOR
TYPE
CONDENSER
FAN
CONDENSER
COIL
AfR
Fl NOT
(SEE NOTE)
CHARGE
CENTRIFUGAL
(Dia. x M. in.)
FAN MOTOR HP
(DIRECT-DRIVE)
FAN MOTOR HP
(BELT-DRIVE)
d33a SN1021
FINS PER INCH
('H 'bS)
V32IV 30VA
HERMETICALLY
SEALED
PROPELLER
DIA. (In.)
FAN MOTOR HP
NOM. CFM TOTAL
d330 SMOU
FINS PER INCH
FACE AREA
(Sq. Ft.)
QUANTITY
PER UNIT
(15 "X20"X1")
QUANTITY
PER UNIT
(14 "X25 "X1")
TOTAL FACE
AREA (sq. ft.)
REFRIGERANT
R -22 (lbsJoz.)
036
12 x 10
th
1
3
13
3.6
SCROLL
TYPE
24
1 /a
3,400
1
16
17.1
2
1
6.3
5/8
048
12 x 10
3 /a
1 th
3
13
4.3
24
1 /a
3,400
1
16
17.1
2
1
6.3
6/8
060
12 x 10
1
1
3
13
5.1
24
1/a
3,400
1
22
17.1
2
1
6.3
6/8
072
12 x 11
1
1
4
13
5.1
24
1/a
3,300
2
16
16.7
2
1
6.3
10/0
CAPACITY RATINGS - Cooling / Gas Heating
• Not ARI Listed.
530.18 -TG1Y
'Called h aaordana wth the Unitary Snell Equipment certification program, ahkh it based an AR Standard 210240. 'Rated In acordance with ARt Standard 270. '(etas we available as aceessaes - d with tinge
point paver supply.' Called In accordance with the Unitary Large Equipment aPolaatn program, weld' Is based an ARt Standard 340060.
SEER • Seasonal Ensryy E em,/ Ratio -the total coding output In BTlrs during • nomrl weal usage period Sr coring bided by the total electric power Input in eaEhours doing the same period.
EER - Enegtr Efficiency Ratio -the coating apady In BWY per hour (Btuh) Added byihe power trout in sees at any Oven set d rating acibans, euressed In BTUN per watt (BTUHMet0.
AFUE -Annual Fuel Utilization Etlkkrncy- dNandned In accordance with DOE teat prooedne.
S.S.E. -tom' State Money (Pearl Cuaa6).
• At a dstence d 10 ftftcm the blower.
NOTE: These values have been derived using a model of sound prapagatan, measuring tie indoor ambient sound ovals ten feet torn the source. The ABA values provided are br reference
only. Calculation of dBA values cover matters of system design end application. This Constitutes an exception to any specification or guarantee requiring a dBA value or sound data an
any other bin Men sound power level ratings.
NOTE: Filter racks are adapted Sr 1' or? lhidc filters.
Unitary Products Group
3
Evaporator
m114710117 UM or ?Mr
on Llonaenser God
85°F
'. ._, -:� °
Total,
MBH
Rowe
KW
Sensible apaaty 1 , MBH
Total
Cap.'
Ft
Input'
Sensible Capaclty MBH
CFM
°F
Enterin Dry Bulb, °F
Entering
Dry Bulb, °F
86
83
8Q
77
74
71
68
Entering Dry Bulb, °F
8
I 83 80
77
MBH
KW
86
83
<:80
77 74
71
68
KW
67
62
4.8
77 174
71
3
32
25
-
65
`
50
-
43
37
31
24
57
-
00
62
57
27
62
56
50
43
37
31
24
60
5.3
60
54
48
42
35
29
23
50
57
55
4.7
57
57
57
51
44
38
32
53
5.3
53
53
53
47
41
34
28
44
44
44
4.7
55
55
55
48
42
36
29
51
5.4
51
51
51
44
38
32
6.5
42
72
42
4.9
30
24
65
5
41
22
29
23
57
25
43
38
D Y
4.8
4
A 4
V'
I
C 1
35
24
59
52
57
51
32
40
34
28
22
50
47
42
4.7
'
30
24
18
4 5
33
53
5
53
37
47
41
35
29
44
44
44
38
32
26
20
42
31
50
5 -3
50
50
, ,
44
39
33
27
42
`3r
47
d
4
31
-
28
-
42
5.3_
39
33
28
22
57
6.6
0'.
57
N u
25
N 4
25
81
38
) .
39
23
34
-r
i N
, 5
5
n IN
48
52
43 .
52
38
47
32
42
27
36
22
31
50
45
4
29
24
18
37
32
48
5
50
sr1
44
39
34
6.4
44
72
--
4.8
4.7
41
28
31
27
22
-
-
61
5.4
__
40
35
35
26
21
42
28
1750
62
4
'
51
7 l
41
36
32
27
22
56
5.1
49
44
19
35
30
25
21
37
57
.
27
4.6
53
26
-
51
47
42
37
32
50
5.2
50
50
28
43
39
34
29
45
41
36
4.6
51
22
49
44
40
35
30
47
5.2
47
47
34
41
36
41
41
72
--
4.8
4.7
37
33
N M Y
25
21
-
-
58
5.4
36
32
28
24
20
32
27
1500
62
38
46
42
34
30
26
21
53
5.2
44
40
36
32
28
24
20
6.5
57
28
4.6
51
51
43
39
35
31
47
5.2
47
47
44
40
36
32
27
43
6.4
4.6
49
49
41
37
33
29
45
5.3
45
45
42
38
34
29
27
26
23
21
38
37
6.3
6.2
38
25
Evaporator
Coil
m114710117 UM or ?Mr
on Llonaenser God
105 °F
115 °F
Total,
Total
Cap.'
Fbwe
Sensible Capaaty MBH
otal
Poway
1
Sensible Capacity ,MBH
CFM
WB
°F
MBH
Input`
KW
Entering
Dry Bulb, °F
Cap.'
Input'
Entering Dry Bulb, °F
8
I 83 80
77
74
71
68
MBH
KW
86
80
77 174
71
68
72
67
61
55
6.1
5.9
48
55
41
35
29
22
-
-
57
6.7
46
39
33
27
20
2500
62
49
52
46
39
33
27
20
50
6.6
50
50
43
37
31
24
18
57
47
5.9
49
49
49
42
36
30
23
44
6.5
44
44
44
38
31
25
19
5.9
47
47
47
40
34
28
21
42
6.5
42
42
42
36
30
26
22
-
-
57
6.6
43
38
32
26
20
23
-
17
2250
4
) u
3.
38
32
26
20
50
6.5
50
47
42
36
30
24
18
42
37
31
25
44
6.4
44
44
44
38
32
26
20
40
35
29
23
42
6.4
42
42
47
36
31
--
6.0
5.8
42
21
-
57
6.6
41
36
25
20
25
19
2000
&
5.7
52
. i
r •
_t
31
20
50
6.5
50
45
34
29
24
18
48
37
27
44
6.4
44
44
38
33
28
22
5.8
46
35
25
42
6.3
42
42
-
'
32
Y
29
24
19
-
-
53
37
32
.
27
18
26
-
21
-
1750
) u
F. r.
vu
r•
38
33
28
24
19
46
vi
45
41
36
26
22
17
44
39
34
30
25
41
41
41
39
30
25
21
42
37
32
28
23
39
39
39
38
29
24
72
67
54
48
6.0
5.8
34
30
26
22
18
-
-
49
6.5
28
IIN N Al
..,,
20
16
19
1500
62
43
42
38
34
30
26
22
18
43
6.4
36
28
24
20
16
57
41
5.7
5.8
43
41
43
41
39
38
35
34
31
30
27
26
23
21
38
37
6.3
6.2
38
31
27
23
19
37
30
26
22
18
I
6
530.18 -TG1Y
COOLING CAPACITIES - 5 TON (DCE / DCG060)
Air On
NOMINAL RATING
Temperature of Air on Cond
owe - mob -tan tie Blower Perbirence Table, multiply this value by 1415 MBH /Kwb determine the
racks heat, and deduct lls heat from he gross capacity othe unit.
2 T
'Riese
e mitig KlNde l canpressar and tie condenser fen motes but not the apply sir bbwer mote: rota condenser fan motarpowerInput ls 0.36 KNL Refe�-to tie !bower Performance
apply air blower motor.
ALL SENSIBLE CAPACITY
Unitary Products Group
:RIPTION
RESISTANCE. IWG
CFM
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
)om¢er 3
0.07
0.08
0.09
0.11
0.13
0.15
0.17
0.20
0.23
0.26
0.30
Electric
5 -15 KW
0.04
0.05
0.06
0.07
0.08
0.10
0.12
0.14
0.16
0.19
0.22
20 - 30 KW
0.06
0.07
0.08
0.09
0.11
0.13
0.15
0.17
0.20
0.23
0.26
Bottom Duct Connections
0.06
0.07
0.08
0.09
0.10
0.11
0.12
0.14
0.16
0.19
0.22
Cooling Only2
0.08
0.10
0.12
0.14
0.16
0.18
0.20
0.23
0.26
0.29
0.32
MODEL
BLOWER
RANGE
(RPM)
MOTOR'
ADJUSTABLE
MOTOR PULLEY
FIXED
BLOWER PULLEY
BELT
HP
RPM
FRAME
SIZE
SERVICE
FACTOR
PITCH
DIA
(in.)
BORE
(in.)
PITCH
DIA.
fin.)
BORE
(in.)
PITCH
LENGTH
(in.)
DESIG-
NATION
DCE / DCG 036
790 -1120
1
1725
56
1.15
2.4 - 3.4
%
5.7
1
37.3
A36
DCE / DCG 048
790 -1120
1
1725
56
1.15
2.4 - 3.4
7 4
5.7
1
37.3
A36
DCE / DCG 060
850 -1220
1
1725
56
1.15
2.4 - 3.4
%
5.2
1
37.3
A36
DCE / DCG 072
900 -1250
1
1725
56
1.15
2.8 - 3.8
Vs
5.2
1
37.3
A36
MODEL
DCE
DCG
POWER
S
VOLTAGE
LIMITATIONS
(SEE NOTE 1)
SCROLL
COMPRESSOR
COND.
M FA
FLA
SUPPLY
AIR
BLOWER
MOTOR,
FLA
MINIMUM
CIRCUIT
AMPACITY
MAX.
FUSE
SIZE,
(SEE NOTE 2)
AMPS
MAX.
HACR
BREAKER
SIZE,
AMPS
MIN.
MAX.
RLA
LRA
036
208/230 -1-60
208/230-3-60
4603 -60
575 -3-60
187
187
414
518
187
187
414
518
18.0
11.4
6.2
5.0
105.0
90.0
45.0
36.0
1.3
1.3
0.8
0.8
4.4
4.4
2.2
2.2
28.2
20.0
10.8
9.3
45
30
15
15
45
30
15
-
048
208/230 -1.60
208230.3 -60
460-3-60
575-3-60
187
187
414
518
(NU)m
24.4
14.1
7.1
5.6
140.0
105.0
55.0
44.0
1.3
1.3
0.8
0.8
5.0
5.0
2.2
2.2
36.8
23.9
11.9
10.1
60
35
15
15
60
35
15
-
060
208230 -1-60
208/230-3-60
460 -3-60
575 -3-60
208/230-1-60
208/230-3-60
460 -3-60
575 -3-60
C1NA$
28.9
16.0
8.0
6.4
165.0
125.0
67.0
50.0
1.3
1.3
0.8
0.8
6.6
6.6
3.3
3.3
44.0
27.9
14.1
12.1
70
40
20
15
70
40
20
-
072
208230 -3-60
460-3-60
575-3-60
187
414
518
253
504
630
20.3
10.2
8.2
146.0
73.0
58.4
1.3
0.8
0.8
6.8
3.6
3.6
33.5
17.2
14.7
50
25
20
50
25
-
CLCI• I IVLAL UA IR - tsasic units witn beIL -unve
MODEL
DCE
DCG
POWER
SUPPLY
VOLTAGE
LIMITATIONS
(SEE NOTE 1)
SCROLL
COMPRESSOR
COND.
FAN
MOTOR,
FLA
SUPPLY
AIR
BLOWER
MOTOR,
FLA
MINIMUM
CIRCUIT
AMPACITY
MAX.
FUSE
SIZE,
(SEE NOTE 2)
AMPS
MAX.
HACR
BREAKER
SIZE,
AMPS
MIN.
MAX.
RLA
LRA
036
208/230 -1-60
208/230-3-60
460-3-60
575 -3-60
187
187
414
518
BRAE
18.0
11.4
6.2
5.0
g000
ssypi
1.3
1.3
0.8
0.8
5.3
5.3
3.1
3.1
29.1
20.9
11.7
10.2
45
30
15
15
45
30
15
-
048
208/230 -1-60
208/230-3-60
460 -3-60
575 -3-60
187
187
414
518
RRAE
24.4
14.1
7.1
5.6
140.0
105.0
55.0
44.0
1.3
1.3
0.8
0.8
8.6
5.2
2.6
2.0
40.4
24.1
12.3
9.9
60
35
15
15
60
35
15
-
060
208/230-1-60
208/230-3-60
460 -3-60
575 -3-60
187
187
414
518
NN
28.9
16.0
8.0
6.4
165.0
125.0
67.0
50.0
1.3
1.3
0.8
0.8
8.6
6.0
3.0
2.4
46.0
27.3
13.8
11.2
70
40
20
15
70
40
20
-
072
208/230-3-60
460 -3-60
575 -3-60
187
414
518
253
504
630
20.3
10.2
8.2
146.0
73.0
58.4
1.3
0.8
0.8
7.3
3.7
2.8
34.0
17.3
13.9
50
25
20
50
25
-
STATIC RESISTANCES
EXTERNAL STATIC PRESSURE DROP
'Deduct these resistance values tan the wobble external stalk pressure tow In he respective Maw P, tnnance Ads.
'Add Mess resistance values to he avaaabs static resistance In he respective Blaver Pkhnnnc.TIAN.
' Ds pnaaue btu Ike eoawrtzerNgeatertr103%a tedcni Natr100%nomt. fasntebtrmeMANI=*cast Men Mlsslhan025PAO tie maul &Wiest CFM AA9f/escronixcapen/m.
* Al motors have solid Wad and we irherenly protected.These motors an besdededto operas Ns hi svv, t* trbeause they are loaded NIA* modng t, upstream of any heating dedoe.
ELECTRICAL DATA - Basic Units with Direct -Drive
530.18 -TG1Y
NOTES: 1. Uthaoa Range Win accordance vrih ARI Standard 110. 2. Dual ssrnsid. than du aytype.
NOTES: 1. Rated N accordance vMh ARI Standard 110, filtration range W. 2. Dual slanerd, line Ada/ type.
Unitary Products Group
11
HOLE
KNOCKOUT
SIZE
DIA
USED FOR
A
718" •
Control Wring
Side or Bottom ""
B
2" ,
Power Wiring
Side or Bottom
C
1 -5/5"
Gas Pi 'n Front
D
1 -11?
Gas - .' , Bottom
Front
DCE Units
24"
DCG Units
32"
Bade
12" (Less Economizer)
36" (With Economizer
or Fixed Air/Motorized
Damper)
Left Side
(Filter Access)
24 "(Less Economizer)
36" (With Economizer)
Right Side
(Cond. Coil)
24"
Below Unit
0"
Above Unite
72" (For Condenser
Air Discharge)
UNIT DIMENSIONS (DCE AND DCG - 3, 4, 5 & 6 TON)
FILTER
ACCESS
DHE Units
4 S. Ton
I DCG UNITS I
3 -6 TON
FIELD.SUPPUED
DISCONNECT SWITCH
LOCATION
(Direct-Drive inks)
5-3
FILTER
ACCESS
T
3t4" PVC FEMALE
COND. DRAIN
(See Derail "A ")
BOTTOM SUPPLY
& RETURN AIR
OPENINGS (SEE NOTE)
B - POWER WIRING ENTRY
A - CONTROL WIRING ENTRY
FIELD-SUPPUED
DISCONNECT SWITCH
LOCATION
(Direct-Drive units)
sit" PVC FEMALE
COND. DRAIN
(Sea Detail "A")
BOTTOM SUPPLY
8 RETURN AIR
OPENINGS (SEE NOTE)
B • POWER WIRING ENTRY
A - CONTROL WIRING ENTRY
Unitary Products Group
CONTROL
SOX
ACCESS
All dimensions are In inches. They are
subject to change without notice. Certified
dimensions will be provided upon request.
CCMtTROL BLOWER
BCgC ACCESS
ACCESS
324/4
VENT MR
OUTLET HOOD
1
SCROLL
COMPRESSOR
ACCESS
ELECTRIC
MEAT
ACCESS
2-1/2
UNIT BASE WITH RAIL$
Shown *carat* to Bungle
bottom duct openings and
power oonneodon factions.
NOTE: For curb-mounted units,
Mar to fie duct hanger dimension
of the curb for the proper site d the
supply and return air duelsonnaetans.
CONDENSER
SCROLL COMPR.
ACCESS
MR
INLET HOOD
- GAS HEAT
C ACCESS
GAS SUPPLY ENTRY
(LT NPTI AT GAS VALVE)
/ 2-1R
D
GAS SUPPLY ENTRY
NPTI AT GAS VALVE)
UNIT BASE WITH RAILS
Shown separately to Illustrate Illustrate bm
bet duct openings. power and
gas piping oonnaaai tmdkns.
NOTE: For curbtriounted units,
raw la the duct hanger dimensions
at the curb Jr tie proper size of the
supply and return air duct cunnscdons.
I�i:•iiCt:TdYd.°nPi3a "`3� ...
UTILITIES ENTRY DATA
* Knockouts it the bosom d ire wit an be located by the
doe hi the IOW:Vi n.
" "Do ad remove the knockout ring.
CLEARANCES
1 Unts may be installed on contusabie toots made tan
rood or clan A, B or C roof avowing material.
Unto must be Mated adoaa Overhanging structures
or shrubs should net obaud condoner at dkdlrge outdo
NOTES:
LiCEAtudigo Unto and ducbcerk rs appaed truce cleanest to
combustible materials vlten quipped soh sleddc heaters.
f s;A1•dearrra mud be provided bireenartycombusti-
ble mater. and the supply akdudrak Lor
dYMae d3 fad fan the unit.
The poduds damtusdon mud not be dosed
acaamdate rSiin a confined spa and ',circulate.
Locate unit so that the vent air add hood is at least:
• Three (3) feet above any forced air inlet located within 10
horizontal feet (etdudi ng those integral to the snit)
• Far (4) feet below, 4 horizontal feet from, or 1 foot above
any door or gravity sir Wet into tie building.
• Far (4) feet torn electric metes, gas meters, regualtors
and relief equipment
RETURN AIR
SUPPLY AIR
CONDENSER AIR
OUTDOOR AIR
(Economizer)
530.18 -TG1Y
17
BASIC UNIT
OPTIONS/ACCESSORIES
DCG
SIZE
(heat)
UNIT WEIGHT'
(lbs.)
CORNER WEIGHTS*
(location, lbs.)
DCE
UNIT WEIGHT'
(lbs.)
CORNER WEIGHTS'
(location, lbs.)
DESCRIPTION
WEIGHT
(lbs.)
'A'
- B'
'C'
=D•
•A'
•B•
- C -
'D'
036
(40 Mbh)
625
180
172
133
140
036
565
160
157
123
125
ECONIMIZER
50
036
(79 Mbh)
635
180
177
138
140
048
615
173
170
135
137
MOTORIZED
OUTDOOR
AIR DAMPER
26
OM h)
(60
675
193
185
145
152
060
640
180
177
140
143
048
(99 Mbh)
685
193
190
150
152
1 072
720
171
196
189
164
ELECTRIC
(nom. KW)
DCE only
5 -7
KW
18
(79 Mbh)
700
200
192
150
158
• 'Might = Unit +Ec°"rnIzer
/ CORNER 'D"
1 Kyy5
23
060
(99 Mbh)
710
200
197
155
158
2
KW
28
072
(79 Mbh)
775
186
209
201
179
ROOF CURB MOUNTING
92
072
(99 Mbh)
785
186
214
206
179
RELIEF /FIXED
AIR DAMPER
10
BELT -DRIVE
BLOWER
5
ROOF CURB DIMENSIONS - (DCE and DCG - 3, 4, 5 & 6 TON)
DIM.
Y
X
Unitary Products Group
SCROLL DUCT 2' TYP, AND CONDENSER END
SUPPORT RAILS OF UNIT
19-12'
37.1 /4•
DUCT SIZES:
Supply Air = 19' x 19'
Return Air - 18'x19'
RETURN'
AIR
CORNER 'A"
3 -5 TON
19-3/4"
40 -3/4'
6 TON
22
44-
BACK
OF UNIT
SUPPLY'
AIR
COMPONENT WEIGHTS AND CENTER OF GRAVITY
APPROXIMATE
CENTER OF GRAVITY
FRONT OF UNIT
CORNER 'B'
FRONT
OF UNIT
'Supply and Return Air (Including duct support rafts)
shown are typical for pottom duct applications.
For location of hodnintAl duct applications
(on back of unit), refer to Unit Dimension details.
BACK OF UNIT
8214
Y
CORNER "C"
CONDENSER COIL
END OF UNIT
530.18 -TG1Y
19
Air on Evap-
orator Coil
Temperature at Air on Condenser Coil
76°F
85 °F
CFM
YV
(°)
Total
Cap.
(MBH)
Totait
Input
(l )
Sensible Capacity (MBH)
Return Dry Bulb (
Total
Cap:
Totalt
Input
(kW)
Sensible Capacity (MBH)
Return Dry Bulb (°F)
86
83
80
77
74
71
68
(MBH)
86
83
80
77
74
71
68
2260
72
106.1
6.5
61.2
34.8
48.4
42.0
35.5
-
-
100.7
7.1
58.8
52.4
46.0
39.6
33.1
-
-
67
99.1
6.3
75.8
69.4
63.0
56.5
50.1
43.7
37.3
92.8
6.9
73.5
67.0
60.6
54.2
47.8
41.4
35.0
62
91.8
6.2
91.8
85.0
78.6
72.2
65.8
59.3
52.9
85.7
6.8
85.7
81.0
74.6
68.2
61.7
55.3
48.9
57
89.3
6.2
89.3
89.0
82.6
76.2
69.8
63.4
57.0
84.7
6.8
84.7
83.7
77.3
70.9
64.5
58.1
51.7
2625
72
110.1
6.6
67.2
59.7
52.1
44.5
36.9
-
-
104.3
72
64.9
57.3
49.7
42.1
34.5
-
-
67
102.8
6.4
82.9
75.3
67.8
602
52.6
45.0
37.4
962
7.0
80.7
73.1
65.5
57.9
50.4
42.8
35.2
62
95.3
6.3
95.3
91.9
84.6
77.0
69.4
61.9
54.3
88.7
6.8
88.7
86.4
80.6
73.0
65.4
57.9
50.3
57
92.7
6.3
92.7
92.6
89.0
81.4
73.8
66.2
58.6
87.7
6.8
87.7
872
83.6
76.0
68.4
60.8
53.3
6000
72
114.1
6.6
73.3
64.5
55.8
47.0
38.3
-
-
107.9
72
70.9
62.2
53.4
44.7
35.9
-
-
67
106.6
6.4
90.1
81.3
72.6
63.8
55.1
46.3
37.6
99.5
7.1
87.9
79.2
70.4
61.7
52.9
44.2
35.4
62
98.8
6.3
98.8
98.8
90.6
81.9
73.1
64.4
55.6
91.8
6.9
91.8
91.8
86.6
77.9
69.1
60.4
51.6
57
96.1
6.3
96.1
96.1
95.3
86.6
77.8
69.1
60.3
90.7
69
90.7
90.7
89.8
81.1
72.3
63.6
54.9
6376
72
115.3
6.7
78.5
68.6
58.6
48.7
38.7
-
-
109.2
7.3
76.3
66.3
56.4
46.4
36.4
-
-
67
107.7
6.5
98.1
862
76.3
66.3
56.3
46.4
36.4
100.7
7.1
942
84.3
74.3
64.4
54.4
44.4
34.5
62
99.8
6.4
99.8
99.8
95.8
85.8
75.8
65.9
55.9
921
6.9
92.9
92.9
90.3
80.4
70.4
60.5
50.5
57
97.1
6.4
97.1
97.1
96.7
86.8
76.8
66.8
56.9
91.9
6.9
91.9
919
91.4
81.5
71.5
61.5
51.6
3750
72
116.5
6.8
83.8
72.6
61.5
50.3
39.1
-
-
110.6
7.3
81.7
70.5
59.3
48.1
36.9
-
-
67
108.8
6.6
106.0
91.1
79.9
68.8
57.6
46.4
352
101.9
7.1
100.5
89.4
782
67.0
55.8
44.7
33.5
62
100.9
6.4
100.9
1009
100.9
89.7
78.5
67.4
562
94.0
7.0
94.0
94.0
94.0
82.9
71.7
60.5
49.3
57
98.1
6.4
98.1
98.1
98.1
86.9
75.8
64.6
53.4
93.0
7.0
93.0
93.0
93.0
81.8
70.6
59.5
48.3
96 °F
105 °F
2250
72
95.3
7.7
56.4
50.0
43.6
372
30.8
-
-
879
8.3
53.5
47.1
40.7
34.3
27.9
-
-
67
86.6
7.5
71.1
64.7
58.3
51.9
45.5
39.1
32.6
79.1
8.1
67.9
61.5
55.1
48.6
422
35.8
29.4
62
79.5
7.3
79.5
77.0
702
64.1
57.7
51.3
44.9
73.2
79
73.2
70.9
64.5
58.0
51.6
452
38.8
57
80.1
7.3
80.1
78.5
72.0
65.6
592
52.8
46.4
742
72
742
72.5
66.1
59.6
532
46.8
40.4
2625
72
98.5
7.8
62.5
54.9
47.3
39.7
322
-
-
90.7
8.4
59.5
52.0
44.4
36.8
292
-
-
67
89.5
7.6
78.5
70.9
63.3
55.7
48.1
40.6
33.0
81.6
8.1
74.3
67.6
60.1
52.5
44.9
37.3
29.7
62
82.1
7.4
82.1
80.9
76.6
69.0
61.4
53.9
46.3
75.5
7.9
75.5
74.3
70.3
62.7
55.1
47.6
40.0
57
82.7
7.4
82.7
819
78.2
70.6
63.0
55.5
479
76.5
8.0
76.5
75.7
72.1
64.5
J
49.3
41.7
3000
72
101.7
7.9
68.5
59.8
51.1
42.3
33.6
-
-
93.4
8.4
65.6
56.8
48.1
39.3
30.6
-
-
67
92.4
7.7
85.8
77.0
68.3
59.5
50.8
42.0
33.3
84.1
8.2
80.8
73.8
65.1
56.3
47.6
38.8
30.1
62
84.8
7.5
84.8
84.8
82.6
73.9
65.1
56.4
47.6
77.7
8.0
77.7
77.7
762
67.4
58.7
49.9
412
57
85.4
7.4
85.4
85.4
84.4
75.6
66.9
58.1
49.4
78.9
8.0
789
78.9
78.1
69.3
60.6
51.8
43.1
3375
72
7.9
74.0
64.1
v a
SPZ
44.1
342
-
Hr
94.8
8.5
71.1
61.2
512
41.2
31.3
-
-
67
7.7
90.4
82.3
62.4
52.4
42.5
85.4
8.3
83.7
78.4
69.3
59.3
49.4
39.4
29.4
62
7.5
86.0
86.0
75.0
65.0
55.0
789
8.0
78.9
78.9
78.1
68.2
582
48.3
38.3
57
86.6
7.5
86.6
86.6
86.1
762
662
56.2
46.3
80.1
8.1
80.1
80.1
79.7
69.7
59.7
49.8
39.8
3750
72
104.6
7.9
79.5
68.3
57.1
46.0
34.8
-
-
96.3
8.5
76.7
65.5
54.3
43.1
31.9
-
-
67
95.1
7.7
95.1
87.6
76.4
65.3
54.1
42.9
31.7
86.7
8.3
86.7
83.0
73.5
62.3
51.1
40.0
28.8
62
87.2
7.5
87.2
872
872
76.0
64.9
53.7
42.5
80.1
8.1
80.1
80.1
80.1
68.9
57.8
46.6
35.4
57
87.9
7.5
87.9
87.9
87.9
76.7
65.5
54.3
432
81.3
8.1
81.3
81.3
81.3
70.1
58.9
47.7
36.6
116 °F
125 °F
2250
72
80.5
8.9
50.6
442
37.8
31.4
25.0
-
-
73.0
9.4
47.7
41.3 34.9
28.5
22.1
-
-
67
71.7
8.6
64.6
582
51.8
45.4
39.0
32.6
262
642
92
61.4
55.0
48.6
42.1
35.7
29.3
22.9
62
66.9
8.4
66.9
64.8
58.4
512
45.5
39.1
32.7
60.6
9.0
60.6
58.7
522
45.8
39.4
33.0
26.6
57
68.3
8.5
68.3
66.5
60.1
53.7
47.2
40.8
34.4
62.5
9.1
62.5
60.5
54.1
47.7
41.3
34.8
28.4
2625
72
82.8
8.9
56.6
49.0
41.5
33.9
26.3
-
-
74.9
9.5
53.7
46.1
38.5
30.9
23.4
-
-
67
73.7
8.7
70.2
64.4
56.8
49.3
41.7
34.1
26.5
65.8
9.3
65.8
612
53.6
46.0
38.4
30.9
23.3
62
68.8
8.5
68.8
67.7
64.0
56.4
48.8
41.3
33.7
62.1
9.0
62.1
612
57.7
50.1
42.6
35.0
27.4
57
70.3
8.6
70.3
69.4
65.9
58.3
50.7
43.2
35.6
64.1
9.2
64.1
63.1
59.7
52.2
44.6
37.0
29.4
3000
72
85.1
9.0
62.6
53.9
45.1
36.4
27.6
-
-
76.8
9.6
59.6
50.9
422
33.4
24.7
-
-
87
75.8
8.8
75.8
70.6
611
53.1
44.4
35.6
269
67.5
9.4
67.5
67.4
58.7
49.9
412
32.4
23.7
62
70.7
8.6
70.7
70.7
69.7
60.9
52.2
43.4
34.7
63.7
9.1
63.7
63.7
63.2
54.4
45.7
36.9
28.2
57
72.3
8.7
72.3
72.3
71.7
63.0
542
45.5
36.7
65.8
9.3
65.8
65.8
65.4
56.7
479
39.2
30.4
3375
72
86.5
9.1
68.2
582
48.3
38.3
28.4
-
-
782
9.6
65.3
55.3
45.4
35.4
25.4
-
-
67
77.1
8.8
77.1
74.4
66.2
56.2
46.3
36.3
26.3
68.7
9.4
68.7
68.7
63.1
53.2
432
33.2
23.3
62
71.9
8.6
71.9
71.9
71.4
61.4
51.4
41.5
31.5
64.8
9.1
64.8
64.8
64.6
54.6
44.6
34.7
24.7
57
73.5
8.7
73.5
73.5
732
632
53.3
43.3
33.3
662
9.3
66.9
66.9
66.7
56.8
46.8
36.8
26.9
3750
72
87.9
9.1
73.8
62.6
51.4
40.3
29.1
-
-
79.5
9.7
70.9
59.8
48.6
37.4
26.2
-
-
67
78.3
8.8
78.3
78.3
70.5
59.4
482
37.0
25.8
69.9
9.4
69.9
692
67.6
56.4
452
34.1
22.9
62
73.0
8.6
73.0
73.0
73.0
61.9
50.7
39.5
28.3
66.0
92
66.0
66.0
66.0
54.8
43.6
32.4
21.2
57
74.7
8.7
74.7
74.7
74.7
63.5
52.3
41.1
30.0
68.1
9.3
68.1
68.1
68.1
56.9
45.7
34.5
23.4
036 - 21491-004- A-0405
TABLE 6: COOLING CAPACITY DF090 (7 -1/2 TON) UNIT
' The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH =3.415 x kW. Refer to the appropriate Blower Perfor-
mance table for the kW of the supply air blower motor.
t These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
Unitary Products
17
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M07 -157 DATE: 07 -20 -07
PROJECT NAME: JAMBA JUICE
SITE ADDRESS: 17100 SOUTHCENTER PY, STE 104
X Original Plan Submittal
Public Works
Response to Correction Letter #
DEPARTM NTS:
G 11_ o1
Bui it g Division
'ERMIT COORD COPY
Structural
r✓
DETERMINATIpN OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Documents/routing slip.doc
2 -28-02
Incomplete
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
El
Response to Incomplete Letter #
Revision # After Permit Issued
Fire Prevention (J Planning Division
❑ Permit Coordinator ❑
DUE DATE: 07 -24-07
DATE:
DATE:
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required
DUE DATE: 08-2 1 -07
Not Approved (attach comments) n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
D15MEM *930BT
Licensee Name
D15 MECHANICAL
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601841514
Iad. Ins. Account Id
Business Type
INDIVIDUAL
Address 1
2020 S 320TH ST #C -90
Address 2
City
FEDERAL WAY
County
KING
State
WA
Zip
98003
Phone
3608885433
Status
ACTIVE
Specialty 1
AIR HEAT,VENTILATION,EVAPORAT
Specialty 2
SHEET METAL
Effective Date
1/30/2007
Expiration Date
1/30/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
ADKISSON, BRENT
OWNER
01/30/2007
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
No Matching Information
Savings Information
Savings
Bank
Name
Bank
Branch
Location
Assignment
of Savings
Number
Effective
Date
Release
Date
Assignment
Type
Impaired
Date
Amount
Received
Date
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License =D 15MEM *930BT 08/03/2007