Loading...
HomeMy WebLinkAboutPermit M07-161 - DANNY FURNITUREDANNY FURNITURE 1181 ANDOVER PK W EXPIRED 02 -06 -OS M07 -161 Parcel No.: 3523049093 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 1185 ANDOVER PK W TUKW C/O EPROPERTYTAX INC DEPT #207 , PO BOX 4900 Contact Person: Name: GARY WIRTA Address: P 0 BOX 82360 , KENMORE WA Contractor: Name: CFM HEATING AND COOLING INC Address: PO BOX 82360 , KENMORE WA Contractor License No: CFMHEHC969CD DESCRIPTION OF WORK: INSTALL (2) NEW ROOF TOP A/C UNITS WITH DROPS AND CONCENTRIC DIFFUSERS Value of Mechanical: $22,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DANNY FURNITURE 1181 ANDOVER PK W , TUKWILA WA MECHANICAL PERMIT Fees Collected: $407.88 International Mechanical Code Edition: 2006 EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425- 481 -3471 Phone: 425 - 481 -6239 Expiration Date: 02/04/2008 M07 -161 08/10/2007 02/06/2008 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -161 Printed: 08 -10 -2007 rnv City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Center Authorized Signature: L l ).3L- Permit Number: M07 -161 Issue Date: 08/10/2007 Permit Expires On: 02/06/2008 Date: 8- o — U� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Date: g - M - 07 :zed 1ca-C Print Name: (TertitY7 I`10CCter This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. Signature: doc: IMC-10 /06 M07 -161 Printed: 08-10 -2007 Parcel No.: 3523049093 Address: Suite No: Tenant: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1185 ANDOVER PK W TUKW DANNY FURNITURE 1: ** *BUILDING DEPARTMENT CONDPI'IONS * ** 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 13: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -161 ISSUED 07/20/2007 08/10/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) M07 - 161 Printed: 08 -10 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air moving equipment upon detection of smoke in the main return duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 18: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (4.4.1.4.2.1)) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 20: In areas that are not continuously occupied, automatic smoke detection shall be provided at each fire control unit(s) location to provide notification of fire at that location. (NFPA 72) 21: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 22: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 23: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 -575 -4407 for ordering information. 24: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 25: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. doc: Cond -10/06 * *continued on next page ** M07 -161 Printed: 08 -10 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: ay pellet doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: bqA -07 M07 -161 Printed: 08 -10 -2007 Site Address: Tenant Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tukwila. wa. us King Co Assessor's Tax No.: k 08 AAAout( PO-(k W IWO A Suite Number: DAAriy s t)1(\; & Name: G ar. ill;( Mailing Address: PO Bok F1 (dP E -Mail Address: Ck A.190.c 1 WE \{ .% co . (pm Company Name: Da kA c\ k: e1 Mailing Address: I2 Ge4ewal �t . f \ tkto Contact Person: 1 E -Mail Address: I ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: f ter Cone o (4 t, C 5- 6(-404 &' (r eQ( ) $e ilCVuc.. City Day Telephone: Fax Number: Mailing Address: 1 25D3 ?j -1 2 e Ke4 # Contact Person: -50\cuN kketr.A\ Oe E -Mail Address: Q:Upplications\Ponns- Applications On line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. Mechanical Permit No. Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** —�- New Tenant: Property Owners Name: Cc�I�Lb 7-ni b44 VA. 1CV`.11S LU C /a Ztt4 L(Xp - Mailing Address: I to0C1) ClAilsitAten 5iAt. (DI Tdku,t ta. (M°► • City State Day Telephone: I.6t1 4 city Fax Number: r j 2u �(t City Day Telephone: Fax Number: State WA- 9 0g3 SITE LOCATION KZ-3m 50.3 Floor: Yes ❑..No CONTACT PERSON - who do we contact when your permit is ready to be issued `/Z5- 18(' /tt D Zip VOA- 16026 State Zip '1z45- q((g5• q(0-11 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record (A,A • 913166 State Zip 2b0 ( .(33 - 8c 41 2 06 ,- Zib- 1330 State Zip H25 - 4 150 - o75 ( 05 " `L'b' k b7 4, q Page 1 of 6 tDING PERMIT INFORMATION — 2O6- 431 -3670' Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Pro outage' ide All Building Area Squat 00 . Floors ent Baser Accessor ictiire; Attached Carport; Detached Carport Uncovered Deck Existing Interi or Remodel Addition to Existing Stru €ture Type of Construction per IBC Type of 'Occupancyper IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection PUBLIC WORKS PERMIT INFORMATION - 206- 433 -0179 Scope of Work (please provide detailed information): Proposed Activities (mark boxes that apply): ❑ ...Right - - way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way Irrigation " Domestic Water Q: Applications\Forms- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 bh Call before you Dig: 1- 800 -424 -5555 ❑ .. Highline ❑... ValVue ❑ .. Renton ❑...Sewer Availability Provided ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ff ❑ .. Work in Flood Zone ❑ .. Storm Drainage Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Renton ❑ .. Seattle Septic System: IU On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size —22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. 11 WO # ❑ ...Water Only Meter Size 11 WO # ❑...Deduct Water Meter Size ❑ ...Sewer Main Extension Public Private ❑...Water Main Extension Public Private 11 FINANCE INFORMATION Fire Line Size at Property Line ❑...Water ❑...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: ; Qty Boiler /Compressor: Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM .r� L Incinerator — Comm/Ind CAL PERMIT INFORMATION - 206.431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: CF M -ea.k ldn€ Cook rnt, , Y11G- Mailing Address: ?o $ o k 62360 � KGv1 M crt Contact Person: (;1119 Vek E - Mail Address: Fax Number: qj5 . • q I Contractor Registration Number: Cfl&4 E RC kbq CO Expiration Date: a2.I Ott / 06 Valuation of Mechanical work (contractor's bid price): $ ZZ 1 000.00 Scope of Work (please provide detailed information): In &4 1) c(WAX) (WAX) 1(`p .) R 4. 4c wells w; *L liy b(I S 4 Con cen - ‘1C, - "iv5vS Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....g Replacement .... El Fuel Type: Electric ❑ Gas....[, Other: Indicate type of mechanical work being installed and the quantity below: Q: Applications \Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9-2006 bh G,A. ge2G City State Zip Day Telephone: 425' Kb ! ` 'bin I Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION CIA k ce,- \ (1 Q1tc Coo Ii n5 5 me Mailing Address: fo Zvi. 8Z (Oo Keil More k GAT t . _ 1 City �/ State Zip Contact Person: U A r N N.7 i�f" Day Telephone: q2 4 U / - 3i7 1 E -Mail Address: 1 Fax Number: -125- qtA- g 67I Contractor Registration Number: GcM N F lice( 6 j CO Expiration Date: 0 / bu / 6i4 Company Name: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ — t - Scope of Work (please provide detailed information): -t--nS70i [ \ l / Z) htW 9QS a``" t Per- roai - Ac r✓n -5 - Building Use (per Int'1 Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: Applications\Forms- Applications On L nn3 -2006 - Permit Applicalion.doc Revised: 9 -2006 bh Page 5 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this applicat Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWD1ER OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: Date Application Accepted: 7Thacti (T 'e lrhk/ M6R,4er ?O 8bx 325 CIO Q: ApplicationsWonns- Applications On tine\ -2006 - Permit Application.doc Revised: 9.2006 bit Date: 67 « Day Telephone: 4 1 1 - 6 ` 'IN • itto City State Zip Date Application Expires: i - 4 1 Staff Initials: w Page 6 of 6 Receipt No.: R07 -01446 Payee: CFM HEATING & COOLING ACCOUNT ITEM LIST: Description rinr.: RAraint -OR MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049093 Permit Number: M07 -161 Address: 1185 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 07/20/2007 Applicant: DANNY FURNITURE Issue Date: Initials: WER Payment Date: 07/20/2007 03:30 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 2309 407.88 Account Code Current Pmts 000/322.100 332.30 000/345.830 75.58 Total: $407.88 Payment Amount: $407.88 0585 07/23 .9710 TOTAL 495.88 Printari n7- 9n -9nn7 Project: P2/6/' ��� �4// / °5 Type of Ins ection: o) -.;v Add ess: (.3 5 / , /i s-°/' Date Called: ' Special Instructions: Date W ted: a m Requester: Phone No: -206- .S /O -/l / v INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 COMMENTS: INSPECTION RECORD Retain a copy with permit proved per applicable codes. ❑ Corrections required prior to approval. .00 REINSPECTION E REQUIRED. P ' or to inspection, fee must be id at 6300 Southcenter = lvd.. Suite 100: Call the schedule reinspection. (Receipt No.: 'Date: LIGHT COMMERCIAL 'T' BAR CEILING RSI's 510 SERIES concentric diffuser systems are d to provide a single point air distribution system. The system: used with either a 1 ceiling or a plaster ceiling. Standard features include: 1. All aluminum diffuser with aluminum return air eggcr 2. Built -in Anti -Sweat gasket. 3. Molded Fiberglass Transition (through five tons). 4. Built -in hanging supports. 5. Diffuser box constructed of fiberglass ductboard (through 7.5 tons) or sheetmetal. Standard benefits include: 1. Even four (4) way airflow. 2. Lightweight design. 3. Factory assembled and sealed. 4. Guaranteed not to "sweat". 5. Guaranteed not to recirculate air flow (short cycle). 6. Return air eggcrate is easily removed. 7. Units are fully insulated (both supply and return). U11/111 RETURN GRILL IES . . - TYPICAL SPECIFICATIONS Furnish and install Rooftop Systems "510 SERIES" concentric diffuser systems. The system shall consist of an aluminum supply diffuser with an aluminum eggcrate return. It shall also have a per- manent (not adhesive) anti -sweat gasket and hanging supports. All units that are five (5) tons and smaller shall have a molded fiberglass interior transition. TURNING VANE TO INSURE PROPI AIRFLOW REVIEWE ODE COMP APPRO s igned may be AUG - 9 2001 FLUSH MOUNT CONCENTRIC DIFFUSER SYST COMMERCIAL 'T' BAR CEILING rte. City Of Tukwila VUILDING DIVISION HANGING FROM THE DIFFUSER ALUMINUM EGGCRATE MOLDED FIBERGLASS TRANSITION TRANSITION SOOT (THRU 5 TONS ONLY) ROOFTOP SYSTEMS, INC. 2405 McIver Lane, Carrollton, Texas 75006 -6510 Mop - ilO Phone (972) 247- 7447 (800) 552 -HVAC F RECEIVEL JUL 202001 PERMIT CENTEt DIMENSIONAL DATA MODEL ft ", R .. - D E : ' F _ G, z SIZE.= 01- 510 -16 47% 2358 13'12 21 45 2214 11'1, 10' %2 16 RD 01- 510 -18 4758 23% 134 21 45 22 10'4 18 RD 01- 510 -20 47% 29% 16% 27 45 22'm 114 13'x= 20 RD 510 SERIES E DIMENSIONAL DATA tOtbL # 01- 510 -22 01- 510 -50 01- 510 -60 01- 510 -80 01- 510 -100 01- 510 -300 4758 474 47 59 59% 65 5 '4 3558 41% 47 % 59% 5958 65% 23'14 29'x. 29'% 35 35'x, 40 D 33 39 45 57 57 63 '�z E 45 45 57 57 57 63 '�z 4 4' /2 4'42 4'42 4'4Z 4'44 18 18 18 24 24 28 2'4 2'/. 2 '�. 2'41 1 1 14 28 32 36 48 54 60 2'42 3'l+ 4'42 4'4r 1 1 "_1 DUCT SIZE 18x28 18x32 18x36 24x48 24x54 2760 FLUSH MOUNT CONCENTRIC DIFFUSER' SYSTEM Model # 01- 510 -16 01- 510 -18 t 01- 510-20 01- 510 -22 01- 510 -50 01- 510 -60 01- 510 -80 01- 510 -100 01- 510 -300 CFM 600 800 1000 1200 1400 1000 1200 1400 1600 1800 2000 2200 2600 2800 3000 3200 3400 3600 4000 4400 4600 5000 5400 5600 6000 6400 6600 7200 8000 8400 8800 9600 10000 10400 10000 11000 12000 13000 Static Pressure 0.09 0.11 0.14 0.17 0.20 0.14 0.17 0.20 0.24 0.30 0.36 0.40 0.17 0.20 0.25 0.31 0.37 0.17 0.21 0.27 0.31 0.34 0.39 0.36 0.42 0.50 0.54 0.39 0.50 0.56 0.63 0.41 0.45 0.50 0.57 0.72 0.90 1.10 Throw in Feet 10 -14 12 -18 15 -20 16 -22 17 -24 15 -20 16 -22 17 -24 18 -25 20 -28 21 -29 22 -30 19 -24 20 -28 21 -29 22 -29 22 -30 22 -29 24 - 33 28 -37 25 -34 24 -33 32-41 28 -37 40 -50 43 -52 45 -56 26 -35 42 -51 44 -54 48 -59 32-41 37-46 42 -51 37-46 46 -56 54 -66 62 -75 Neck Velocity 234 313 391 469 547 391 469 547 625 703 781 859 663 714 765 816 867 844 938 1032 922 938 1083 1000 1071 1143 1179 996 1107 1162 1217 1036 1079 1122 713 785 856 927 Jet Velocity 417 556 691 833 972 694 833 972 1111 1250 1389 1528 1294 1393 1492 1592 1692 1646 1829 2011 1795 1829 2107 2082 2230 2379 2454 2093 2326 2442 2558 2159 2249 2339 1506 1657 1808 1958 Noise Level 18 20 20 25 30 20 25 30 30 35 40 40 30 35 35 40 40 34 40 40 40 40 45 45 45 50 50 45 50 50 50 45 45 50 35 35 40 40 Notes: 1. All data is based on the Air Diffusion Council guidelines. 2. Throw data is based on Terminal Velocities of 75 FPM using isothermal air. 3. Actual noise levels are Tess than those shown. r 510 SER ES CONCENTRIC DIFFUSER ENGINEERING DATA SYSTEMS � . 2405 Mcmmar Lane Carrollton Texas 75006 -6510 Phone (972)247-7447 (800) 552 HVAC Pax {972) 243-0940 OIM SHUTLER CONSULTING ENGINEERS, Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425) 450 -4075 FAX (425) 450 -4076 JOB Danny's Furniture SHEET NO. COVER CALCULATED BY jch CHECKED BY SCALE JOB NUMBER 07 -07.06 OF DATE 7/17/2007 DATE STRUCTURAL CALCULATIONS FOR: NEW HVAC UNITS -- DANNY'S FURNITURE 1181 ANDOVER PARK WEST TUKWILA, WASHINGTON PROPOSED BY: CFM HEATING & COOLING, INC. P.O. BOX 82360 KENMORE, WA 98028 (425) 481 -3471 DESIGN CRITERIA: CODE ROOF LIVE LOAD WIND LOAD SEISMIC ZONE M01- I(I REVIEWED FOR CODE COMPLIANCE APPROVED AUG - 9 2007 ' Oty Of Tukwila D DI IN FILE COEN !! r cow 175 E V 4 ' G � � IPr ��1!g C' AL £' 1. `EXPIRES 11/28/ 2 INTERNATIONAL BUILDING CODE, 2006 EDITION 25 PSF SNOW LOAD 85 MPH ZONE, EXPOSURE "B ", Iw=1.0 SITE CLASS D', Sds =0.93, ap=1.0, Rp=2.5, Ip =1.0 REGE VEL JUL 2 0 2007 PERMIT CENTEr Milli IN CONSULTING ENGINEERS Inc. • 12503 Bel —Red Road, Suite 100 Bellevue, Washington 98005 (425)450 -4075 FAX: (425)450 -4076 TUKWILA, WA SHEET NO SKS -1 OF CALCULATED BY JH DATE 7 -16 -07 SCALE NOTED Job No. 07 -07.06 N 1 M NEW HVAC UNIT (1410 #) PARTIAL ROOF FRAMING PLAN SCALE: 1 /8"= 1 —0" I EXPIRES 11 -28 -2007 MOM CONSULTING ENGINEERS Inc. 4 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425)450 -4075 FAX: (425)450 - 4076 TUKWILA, WA SHEET NO SKS -2 OF CALCULATED BY JH DATE 07 -16 -07 SCALE NOTED Job No. 07 -07.06 (E) 2x6 ® 24 "o.c. (E) GLULAM BEAM ADD 4x8 DF #2 w /LUS48 HANGER EA. END SECTION A/SKS-2 SCALE: 3/4 " =1 ' -0" NEW HVAC UNIT & CURB #10 SCREWS ® 24 "o.c. (E) 2x6 ® 24 "o.c. (E) PURLIN PER PLAN ADD 4x6 DF #2 w /LUS46 EA. END SECTION B/SKS-2 SCALE: 3 " =1' -0" L NEW HVAC J EXPIRES 11 -28 -20071 / UNIT & CURB #10 SCREWS ® 24 "o.c. ADD 4x8 DF #2 MIMI MI IOW MIN | / | | | / � | i . � / L / } 1-- -- T�-- --' | ' | / � ^ �^ � 1 CONSULTING ENGINEERS, INC 12503 Bel-Red Rd., Suite 100 Bellevue, WA 98005 (435) 458'4075 FAX (425) 450-4076 | | ! / | | | | � ! i | ` i ( _ Alike ata.rr -- | C€ —f JOB SHEET NO OF CALCULATED BY DATE • • T --T--; • • • J • - | 4" • . . | [ • ) 1 ■= 110 I•- SHUTLER _N- CONSULTING NEW MIN ENGINEERS, INC 12503 Bel-Red Rd., Suite 100 Bellevue, WA 98005 (425) 450 -4075 FAX (425) 450 -4076 CALCULATED BY Lam' JOB SHEET NO. DATE SCALE OF • brill I LtK CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450 -4075 FAX (425) 450 -4076 JOB SHEET NO CALCULATED BY <�T DATE SCALE -3 OF ����!•• SHUTLER CONSULTING -_ ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450 -4075 FAX (425) 450 -4076 JOB t/y �s SHEET NO. r/ OF CALCULATED BY J DATE SCALE Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.44 Longitude = - 122.25 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B- Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.389 Ss, Site Class B 1.0 0.475 S1, Site Class B Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.44 Longitude = - 122.25 Spectral Response Accelerations SMs and SM1 SMs = FaSs and SM1 = FvS1 Site Class D - Fa = 1.0 ,Fv =1.525 Period Sa (sec) (g) 0.2 1.389 SMs, Site Class D 1.0 0.724 SM1, Site Class D Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.44 Longitude = - 122.25 SDs = 2/3 x SMs and SD1 = 2 /3xSM1 Site Class D - Fa = 1.0 ,Fv = 1.525 Period Sa (sec) (g) 0.2 0.926 SDs, Site Class D — 5 � U t-C = 44t(E) ap ` I. P(kl wE 1Q,o a• e) , 4 5 u — WIAIr>- .v14.04, 64p 'e 0,0-0Zk,k kd Val J/I1) rfr= e / a,a - v r ovi 0 .15 - /toe: '2 • .EAglish CORPORATE Venzon maporama 0 ven The wortd my w.y High Speed Internet • 1/4 7 A EXPORT THE MAP STORE AND RETRIEVE DRIVE ME FROM DRIVE ME TO NEW SEARCH Country: USA Address, Station, Points Of Interest: 1181 ANDOVER PARK W - Pat - C - 0 -- der — State: 98188 WA C4L(mandatoryl_ TUKWILA MAPORAMA INTERNATIONAL 2006 COMPANY I SOLUTIONS I PRODUCTS I TECHNOLOGY I CUSTOMERS I NEWS 0 C 4 _ WEB SEARCH provetvl by eurekster br : • tT, f i 1 ' $61 :gare:' - ''p_ .., , .. 1 (41 erk - TI, NAVTEQ - br - t C2D117 ... NI a ppm m a , 6 4 .......---.... INFORMATIONS 1181 ANDOVER PARK W - T U LA(98188) - USA Lat-Long: 122.25 (- 47.44 (47°26') I - 122.25 (-122°15') WEATHER: t SPONSORED LINKS teiete)(t HOLIDAYS uknetguide COPYRIGHTS - SEND US YOUR COMMENTS ADD TO FAVORITES CUSTI • Now just $1 4.99/mo. for one year • Up to 766 Kbps a Get your first 30 days FREE! PERSONALISE YOUR MA 200 on HOLIDAY DEALS ONL AT TELETEXT holiday FIND YOUR HOLIDAY hypermarket HOLIDAY HYPERMAF CHEAP HOLIDAY DEi 7/13/2007 12:52 PM TECHNICAL - GUIDE 112YORIC Heating and Air Conditioning r fiEff,10 1 " MID EFFICIENCY SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS /ELECTRIC UNITS DF 078, 090, 102 and 120 6 -1/2, 7 -1/2, 8 -1/2 and 10 NOMINAL TONS 10.4 EER eat* - REVIEWED FOR CODE COMPLIANCE APPROVED AUG - 9 2007 ' • City Of Tukwila _ BUILDING DIVISION DESCRIPTION 246699 -YTG -B -0606 ASHRAE 90.1 COMPLIANT YORK DF Predator units are convertible single packages with a common footprint cabinet and common roof curb for all 6- 1/2 through 10 ton models. All units have two compressors with independent refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All DF Predator units are self - contained and assembled on rigid full perimeter base rails allowing for 3 -way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Inde- pendent economizer designs are used on side and down dis- charge applications, as well as all tonnage sizes. Predator units are available in the following configurations: cooling only, cooling with electric heat, and cooling with gas heat. Electric heaters are available as factory- installed options and field- installed accessories. Tested in accordance with: AL Standard Coan.e,d.t N. Indattnar Sanwa Aw Conditioning Equipment FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE RECEIVED JUL 2 0 2007 PERMIT CENTER DESCRIPTION 1 FEATURES 3 FACTORY INSTALLED OPTIONS 5 FIELD INSTALLED ACCESSORIES 6 NOMENCLATURE 10 GUIDE SPECIFICATIONS 43 Fig ^ # LIST OF FIGURES LIST OF TABLES TABLE OF CONTENTS Pg. # 1 PREDATOR® COMPONENT LOCATION (DF120 SHOWN) 3 2 UNIT 4 POINT LOAD 32 3 UNIT CENTER OF GRAVITY 32 4 UNIT 6 POINT LOAD 32 5 UNIT DIMENSIONS 33 6 PREDATOR® ROOF CURB DIMENSIONS 34 7 SUNLINETM' TO PREDATOR® TRANSITION ROOF CURBS 34 8 BOTTOM DUCT OPENINGS 35 9 REAR DUCT DIMENSIONS 35 10 DOWNFLOW ECONOMIZER HOOD DETAIL 36 11 FACTORY INSTALLED DOWNFLOW ECONOMIZER 37 12 FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST 37 13 FIELD INSTALLED HORIZONTAL ECONOMIZER W/POWER EXHAUST 38 14 SLAB ECONOMIZER DOWNFLOW W /POWER EXHAUST 38 15 SLAB ECONOMIZER END RETURN W /POWER EXHAUST 16 COOLING UNIT WITH GAS HEAT WIRING 230 VOLT DIAGRAM 40 17 COOLING UNIT WITH/WITHOUT ELECTRICHEAT WIRING DIAGRAM 41 18 COOLING UNIT WITH GAS HEAT WIRING 460, 575 VOLT DIAGRAM 42 Tbl. # Pg. # 1 ACCESSORIES 8 2 DF PHYSICAL DATA 11 3 DF CAPACITY RATINGS 12 4 UNIT VOLTAGE LIMITATIONS 12 5 COOLING CAPACITY DF078 (6 -1/2 TON) UNIT 13 6 COOLING CAPACITY DF090 (7 -1/2 TON) UNIT 14 246699 -YTG -B -0606 7 COOLING CAPACITY DF102 (8 -1/2 TON) UNIT 15 8 COOLING CAPACITY DF120 (10 TON) UNIT 16 9 ELECTRICAL DATA DF078 (6 -1/2 TON) MID EFFICIENCY W/O PWRD CONVENIENCE OUTLET 17 10 ELECTRICAL DATA DF078 (6 -1/2 TON) MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET 17 11 ELECTRICAL DATA DF090 (7 -1/2 TON) MID EFFICIENCY W/O PWRD CONVENIENCE OUTLET 18 12 ELECTRICAL DATA DF090 (7 -1/2 TON) MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET 18 13 ELECTRICAL DATA DF102 (8 -1/2 TON) MID EFFICIENCY W/O PWRD CONVENIENCE OUTLET 19 14 ELECTRICAL DATA DF102 (8 -1/2 TON) MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET 19 15 ELECTRICAL DATA DF120 (10 TON) MID EFFICIENCY W/ O PWRD CONVENIENCE OUTLET 20 16 ELECTRICAL DATA DF120 (10 TON) MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET 20 17 ELECTRIC HEAT MULTIPLIERS 21 18 DF078 (6 -1/2 TON) SIDE SHOT BLOWER PERFORMANCE 22 19 DF090 (7 -1/2 TON) SIDE SHOT BLOWER PERFORMANCE 23 20 DF102 (8 -1/2 TON) SIDE SHOT BLOWER PERFORMANCE 24 21 DF120 (10 TON) SIDE SHOT BLOWER PERFORMANCE 25 22 DF078 (6 -1/2 TON) DOWN SHOT BLOWER PERFORMANCE 26 23 DF090 (7 -1/2 TON) DOWN SHOT BLOWER PERFORMANCE 27 39 24 DF102 (8 -1/2 TON) DOWN SHOT BLOWER PERFORMANCE 28 25 DF120 (10 TON) DOWN SHOT BLOWER PERFORMANCE 29 26 ADDITIONAL STATIC RESISTANCE DF078, 120 30 27 ADDITIONAL STATIC RESISTANCE DF090, 102 30 28 ELECTRIC HEAT MINIMUM SUPPLY AIR CFM 31 29 INDOOR BLOWER SPECIFICATIONS 31 30 POWER EXHAUST SPECIFICATIONS 31 31 4 POINT LOAD WEIGHT 32 32 6 POINT LOAD WEIGHT 32 33 UNIT WEIGHT 32 34 UNIT HEIGHT 33 35 UNIT CLEARANCES 33 36 ECONOMIZER USAGE 36 2 Unitary Products Group 246699 -YTG -B -0606 Terminal block for hi- vdtage connection Second model nameplate inside hinged access panel Dual stage cooling for maximum comfort Compressor #2 access (high-effi- ciency compressor w /crankcase heater) Simplicity® Control Board wlscrew connector for T -stat wiring and network connections Base rails w /forklift slots (3 sides) and lifting holes Disconnect location (optional disconnect switch) Filter access (2" throw -away) Filter drier (solid core) Slide -out drain pa with steel 3/4" NPT, Female connection Roof curbs in eight and fourteen inch heights. Roof curbs for / Tool -less transitioning from door latch York SunlineTM footprint to the DF Series footprints are also available (field - installed accessory) FIGURE 1 - PREDATOR COMPONENT LOCATION (DF120 SHOWN) FEATURES • Mid Efficiency - Mid efficiency units reach as high as 10.4 EER. Gas /electric units have electronic spark igni- tion and power vented combustion with steady state effi- ciencies of 80 %. These efficiencies exceed all legislated minimum levels and provide low operating costs. • Service Friendly - The Predator incorporates a num- ber of enhancements which improve serviceability. The motor and blower slide out of the unit as a common assembly. This facilitates greater access to all the indoor airflow components, thus simplifying maintenance and adjustment. Service time is reduced through the use of hinged, toolless panels. Such panels provide access to fre- quently inspected components and areas, including the control box, compressors, filters, indoor motor & blower, and the heating section. The panels are screwed in place at the factory to prevent access by children or other Side entry power and control wiring knockouts Compressor #1 access (high - efficiency compressor w /crankcase heater) Condensersection Slide-out motor and dower assemby for easy adjustment and service Belt -drive blower motor Power ventor motor 20 -gauge aluminized steel tubular heat exchanger for long life (stainless steel option) Two-stage gas heating to maintain warm, comfortable temperature Intelligent control board for safe and efficient operation unauthorized persons. It is recommended that the panels be secured with screws once service is complete. Service windows have been placed in both condenser section walls. Rotation of the cover allows easy access to the condenser coils for cleaning or inspection. Both the unit control board and ignition control board uti- lize flash codes to aid in diagnosis of unit malfunctions. Unique alarm codes quickly identify the source of the unit alarm. All units use the same standard filter size. This standard- ization removes any confusion on which filter sizes are needed for replacement. The non - corrosive drain pan slides out of the unit to per- mit easy cleaning. The drain pan is accessed by remov- ing the drain pan cover plate on the rear of the unit. Once the plate is removed, the drain pan slides out through the rear of the unit. Unitary Products Group 3 Part Number Description Weight 1 RC0470 Roof Curb, 8" Height - 1RC0471 Roof Curb, 14" Height - 1 RC0472 Roof Curb, Transition (7.5 T through 12.5 T) - 1 BD0408 Burglar Bars, Downflow - 2TPO4520925 Electric Heat 9kW 230V - 2TPO4521825 Electric Heat 18kW 230V - 2TPO4522425 Electric Heat 24kW 230V - 2TPO4523625 Electric Heat 36kW 230V - 2TPO4525425 Electric Heat 54kW 230V - 2TPO4520946 Electric Heat 9kW 460V - 2TPO4521846 Electric Heat 18kW 460V - 2TPO4522446 Electric Heat 24kW 460V - 2TPO4523646 Electric Heat 36kW 460V - 2TPO4525446 Electric Heat 54kW 460V - 2TPO4520958 Electric Heat 9kW 575V - 2TPO4521858 Electric Heat 18kW 575V - 2TPO4522458 Electric Heat 24kW 575V - 2TPO4523658 Electric Heat 36kW 575V - 2TPO4525458 Electric Heat 54kW 575V - 2TPO4540925 Electric Heat 9kW 230V, 42" Tall Cabinet - 2TPO4541825 Electric Heat 18kW 230V, 42" Tall Cabinet - 2TPO4542425 Electric Heat 24kW 230V, 42" Tall Cabinet - 2TPO4543625 Electric Heat 36kW 230V, 42" Tall Cabinet - 2TPO4540946 Electric Heat 9kW 460V, 42" Tall Cabinet - 2TPO4541846 Electric Heat 18kW 460V, 42" Tall Cabinet - 2TPO4542446 Electric Heat 24kW 460V, 42" Tall Cabinet - 2TPO4543646 Electric Heat 36kW 460V, 42" Tall Cabinet - 2TPO4540958 Electric Heat 9kW 575V, 42" Tall Cabinet - 2TPO4541858 Electric Heat 18kW 575V, 42" Tall Cabinet - 2TPO4542458 Electric Heat 24kW 575V, 42" Tall Cabinet - 2TPO4543658 Electric Heat 36kW 575V, 42" Tall Cabinet - 1 FA0411 Manual Outside Air Damper 0 -35 %, Downflow (Ind. Hood, Damper & Filters, No Barometric Relief) - 1 FA0412 Manual Outside Air Damper 0 -100 %, Downflow (Incl. Hood, Damper & Filters, No Barometric Relief) - 2MD04702724 Motorized Damper, Downflow (Incl. Hood, Damper & Filter, no Barometric Relief) - 2MD04703324 Motorized Damper, Horizontal (Ind. Hood, Damper & Filter, no Barometric Relief) 2EE04705424 Economizer, Downflow (Incl. Barometric Relief & All Hoods) 124 lbs. 2EE04705524 Economizer, Horizontal (Ind. Dampers & Hoods, no Barometric Relief) 97 lbs. 2EE04705224 Economizer, Slab, Downflow (Incl. Dampers only no Hoods or Barometric Relief) 2EE04705624 "Downflow Economizer, Slab type for ERV (no Barometric Relief or FA hood) ", 42" Tall Cabinet - 2PE04703225 Power Exhaust, Downflow, 230V (For Units with Economizer only) - 2PE04703246 Power Exhaust, Downflow, 460V(For Units with Economizer only) - 2PE04703258 Power Exhaust, Downflow, 580V (For Units with Economizer only) - 2EC04700924 Dual Enthalpy Control (Use with Single Enthalpy Economizer) - 1 EH0407 Hood Kit, Downflow Economizer (Included with all Downflow Economizers) 1 RD0411 Barometric Relief Kit, Ductmount for Horizontal Application (Ind. Damper & Hood) 1EH0408 Barometric Relief Kit, Ductmount for Horizontal Application w /Power Exhaust (Ind. Damper & Hood) 25 lbs. 1 EH0409 Barometric Relief / Hood Kit, for Field Installed Slab Econ. w/o ERV (Ind. Barometric Relief & FA Hood) - 2AQ04700424 CO2 Detector Unit Mount - 2AQ04700324 CO2 Detector Space Mount - 2SD04700424 Smoke Detector, Supply or Return (Return Not Available with Horizontal Economizer) - 2MK04700624 Low Limit / Compressor Lockout Kit 1CG0419 Coil Guard (Electric / Electric & HP models) - 1 CG0420 Coil Guard (Gas / Electric models) - 1CG0427 Coil Guard (Electric / Electric & HP Models), 42" Tall Cabinet - 1CG0428 Coil Guard (Gas / Electric Models), 42" Tall Cabinet - TABLE 1: ACCESSORIES 246699 -YTG -B -0606 8 Unitary Products Group Part Number Description Weight 1HG0411 Hail Guard Kit - 1HG0415 Hail Guard Kit, 42" Tall Cabinet - 1GPO405 Gas Piping Kit - 1 NPO442 Propane Conversion Kit - 1 HA0442 High Altitude Kit for Natural Gas - 1 HA0443 High Altitude Kit for Propane - 1 FE0412 Flue Exhaust Extension Kit - 2BC04700106 Gas Heat Kit, -60 deg F, 230V - 2BC04700151 Gas Heat Kit, -60 deg F, 460V - 2BC04700154 Gas Heat Kit, -60 deg F, 575V - 1FL0402 Permanent Filter (Includes (4) Four Filters) - 1FL0423 Permanent Filter (Includes (4) Four Filters), 42" Tall Cabinet - 2DF0401 Dirty Filter Switch - 1FF0410 Filter Frame Kit, Metal - 1FF0411 Metal Filter Frame Kit, 42" Tall Cabinet - 246699 -YTG -B -0606 TABLE 1: ACCESSORIES (CONTINUED) Unitary Products Group 9 Configuration Options (not required for all units) These tour digits wet not be assigned until a quote is requested, or an order placed. — SS Drain Pan — CPC Controller, DFS, APS E = Option 3 Johnson Controller, DFS, APS — — Honeywell Controller, DFS, APS J= Options 1,283 Novar Controller, DFS, APS — — Simplicity InteltiComlort Controller — Simplicity IntelliComfort Controller wiModLioc — 2' Pleated filers S = Option 5 BAS Ready Unit with Beimo Economizer — Shipping Bag W= Options 1, 3, 4, 85 Any Combination of Additional Options that Don't Have an Option Code Pm- assigned Additional Options AA= None AB = Phase Monitor AC = Coil Guard AD = Dirty Filter Switch AE = Phase Monitor & Col Guard AF = Phase Monitor & Dirty Filter Switch AG = Coil Guard & Dirty Filer Switch AH = Phase Monitor, Coil Guard & Dirty Filer Switch RC = Coil Guard, Shipping Bag 8 American Flag TA = Technicoat Condenser Coil TJ = Technicoat Evaporator Coil TS = Technicoat Evaporator & Condenser Coils ZZ = if desired option combination is not fisted above, 2Z wit be assigned and configuration options will be located in digits 15-10 Installation Options A = No Options Installed B = Option 1 C = Option 2 D = Options 1 E = Option 3 F = Option 4 G = Options 1 8 3 H = Options 1 8 4 J= Options 1,283 K = Options 1, 2, & 4 L = Options 1.3 M = Options 1, 2, 3, 8 4 N= Options 283 P = Options 2 & 4 O= Options 2, 3, 8 4 R= Options 3 & 4 S = Option 5 T = Options 1 & 5 U = Options 1, 3, 8 5 V = Options 1, 4, 8 5 W= Options 1, 3, 4, 85 X = Options 3 & 5 Y= Options 465 Z - Options 3,4 Options 1 = Disconnect 2 = Non -Pwtd Cony. Outlet 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 5 = Pwr'd Conv. Outlet Heat Type and Nominal Heat Capacity COO = Cooing Only. No heat installed Gas Heat Options N10 = 100 MBH Output Aluminized Steel N15 = 150 MBH Output Aluminized Steel N20 = 200 MBH Output Aluminized Steel S10 = 100 MBH Output Stainless Steel S15 = 150 MBH Output Stainless Steel S20 = 200 MBH Output Stainless Steel Electric Heat Options E09 =9 KW E18 = 18 KW E24 = 24 KW E38 = 38 KW E54 =54KW NOMENCLATURE Product Category D = A/C, Single Pkg., R -22 Product Identifier F= 10.4EERA/C IDIFI090IN10IAI2IAIAAI3 Nominal Cooling Capacity 078 = 8.5 Ton 090= 7.5 Ton 102 = 8.5 Ton 120 = 10.0 Ton Airflow A = Std. Motor B = Std. Motor/Econo.iBarometrlc Relief (Downflow Only) C = Std. Motor/Econo./Power Exhaust (Downflow Only) D = Std. Motor/Motorized Damper (Downflow Only) E = Std. Motor/Horizontal Economizer (No Baro.) F = Std. Motor /Slab Econo./Power Exhaust (Downflow Only) G = Std. Motor/Slab EconoiBarometric Relief (Downflow Only) N.I. Static Mb. P = Hi Static MUJEconoJBaromeldc Relief (Downflow Only) D = Hi Static MtriEcono /Power Exhaust (Downflow Only) R = Hi Static MtrfMotorized Damper (Downlbw Only) S = HI Static Mtr.Morizontal Economizer (No Baro.) T = HI Static Mfr./Slab Econo./Power Exhaust (Down/ow Only) U - I# Static MtriSlab Econo /Barometric Relief (Downflow only) 6.5 -10.0 Ton York® Model Number Nomenclature Voltage 2 = 208/230 -3-60 4 = 480480 5 = 575 -340 0 �1I Product Generation 3 = Third Generation 4 = Fourth Generation 2 1 A l Product Style A = Style A B = Style B C = Style C 246699 -YTG -B -0606 10 Unitary Products Group Component Models 078 090 102 120 Evaporator Blower Blower, Centrifugal (Dia. X Wd. in.) 15 x 15 12 x 12 12 x 12 15 x 15 Motor, Standard (HP) 1.5 2 3 2 Motor, Optional (HP) 2 3 3 3 Evaporator Coil Rows 3 3 3 4 Fins per Inch 15 15 15 15 Height (in.) 32 32 32 40 Face Area (ft 2) 10.67 10.67 10.67 13.2 Condenser Fan (2 per Unit) Propeller Dia. (in.) 24 24 24 24 Motor (HP, each) 1/3 1/3 3/4 3/4 CFM, Nominal (each) 3400 3400 4400 4400 Condenser Coil (2 per unit) Rows 1 1 Sys 1: 2 Row 2 Sys 2: 1 Row Fins per Inch 20 20 20 20 Height (in.) 44 36 36 44 Face Area (ft 2) 14.5 12 12 14.5 Refrigerant Charge System 1 (lb/oz) 6/12 5/4 9/12 11/1 System 2 (Ib /oz) 6/4 5/0 5/6 11/1 Compressors Quantity 2 2 2 2 Type Recip Recip Recip Recip Air Filters Size (Wd. x Ht. x Thickness in.) 25x20x2 25x16x2 25x16x2 25x20x2 Number Per Unit 4 4 4 4 246699 -YTG -B -0606 TABLE 2: DF PHYSICAL DATA Unitary Products Group 11 Size (Tons) Model Cooling Capacity ARI Ratings* CFM Sound Rating (dB)t Nominal Electric Heat Capacity* (kW) Gas Heat Capacity Gas Size (in. OD) MBH EER IPLV Input (MBH) Output (MBH) Seasonal Efficiency ( %) Temp. Rise ( °F) 078 (6 - 1/2) Cooling Only 75 10.4 11.0 2600 84 - - - - - - Electric Heat 9, 18, 24, 36 Gas Heat - 120 96 80 20 -50 3/4 Gas Heat - 180 144 80 35 -65 3/4 090 (7 - 1/2) Cooling Only 87 10.5 11.6 2516 84 - - - _ - _ Electric Heat 18, 36 Gas Heat - 120 96 80 15-45 3/4 Gas Heat - 180 144 80 30-60 3/4 102 (8.1/2) Cooling Only 99 10.4 10.39 3055 84 - - _ - _ Electric Heat 9, 18, 24, 36 Gas Heat - 120 96 80 15-45 3/4 Gas Heat - 180 144 80 30-60 3/4 120 (10) Cooling Only 115 10.4 10.0 4000 90 - - _ - _ Electric Heat 18, 24, 36, 54 - - - - _ Gas Heat - 180 144 80 20 -50 3/4 Gas Heat - 240 192 80 35-65 3/4 TABLE 4: UNIT VOLTAGE LIMITATIONS POWER RATING MIN. MAX. 208/2304-60 187 252 460 - 3 - 60 432 504 576 - 3.60 540 630 TABLE 3: DF CAPACITY RATINGS 246699 -YTG -B -0606 * Rated at 95 °F ambient 80 °F dry bulb and 67 °F wet bulb t Rated in accordance with ARI 270 standard. $ See Table 17. 12 Unitary Products Group Return Air Outdoor Ambient Temperature 85 °F Outdoor Ambient Temperature 95 °F CFM WF Gross Cap.. (MBH) Inputt Power (kW) Gross Sensible Capacity (MBH) Return Air Dry Bulb ( ° F) Gross Cap: (MBH) Inputt Power (kW) Gross Sensible Capacity (MBH) Return Air Dry Bulb ( ° F) 86 83 80 77 74 71 68 86 83 80 77 74 71 68 3000 72 119.5 8.47 73.6 65.1 56.5 48.0 39.4 - - 119.3 9.31 73.2 64.7 56.1 47.6 39.0 - - 67 116.6 8.49 94.8 86.2 77.7 69.1 60.5 52.0 43.4 114.0 9.25 94.3 85.7 77.2 68.6 60.1 51.5 43.0 62 112.6 8.43 112. 106. 98.3 89.8 81.2 72.7 64.1 109.4 9.11 109. 105. 97.0 88.4 79.9 71.3 62.8 57 109.2 8.41 109. 109. 101. 93.0 84.4 75.9 67.3 109.1 9.16 108. 100. 91.6 83.0 74.4 65.9 57.3 3500 72 122.4 8.52 80.0 69.9 59.8 49.7 39.6 - - 122.0 9.34 80.0 69.9 59.8 49.6 39.5 - - 67 119.4 8.54 102. 92.3 82.2 72.1 62.0 51.9 41.7 116.6 9.28 102. 92.3 82.2 72.1 61.9 51.8 41.7 62 115.3 8.47 115. 112. 104. 94.0 83.9 73.8 63.6 111.9 9.13 111.9 110. 103. 93.1 83.0 72.9 62.8 57 111.8 8.45 111.8 111.8 107. 97.3 87.2 77.1 67.0 111.6 9.19 111.4 107. 97.5 87.3 77.2 67.1 57.0 4000 72 125.2 8.56 86.4 74.8 63.1 51.4 39.8 - - 124.7 9.37 86.7 75.0 63.4 51.7 40.0 - - 67 122.1 8.59 110. 98.4 86.7 75.0 63.4 51.7 40.1 119.2 9.31 110. 98.8 87.1 75.5 63.8 52.1 40.5 62 118.0 8.52 118. 118. 109. 98.2 86.5 74.8 63.2 114.4 9.16 114. 114. 109. 97.8 86.2 74.5 62.8 57 114.4 8.50 114. 114. 113. 101. 90.0 78.4 66.7 114.1 9.22 114. 114. 103. 91.7 80.0 68.4 56.7 4500 72 125.5 8.56 91.5 78.2 64.9 51.6 38.3 - - 125.8 9.41 92.6 79.3 66.0 52.8 39.5 - - 67 122.4 8.59 115. 102. 89.2 75.9 62.6 49.3 36.1 120.2 9.35 115. 104. 90.8 77.5 64.2 50.9 37.7 62 118.3 8.52 118. 118. 113. 99.7 86.4 73.1 59.8 115.4 9.20 115. 115. 112. 99.7 86.4 73.1 59.8 57 114.7 8.50 114. 114. 114. 100. 87.6 74.3 61.0 115.1 9.25 115. 115. 107. 94.4 81.1 67.8 54.6 5000 72 125.8 8.56 96.5 81.6 66.7 51.8 36.9 - - 126.9 9.45 98.5 83.6 68.7 53.8 38.9 - - 67 122.7 8.59 121. 106. 91.7 76.8 61.9 47.0 32.1 121.3 9.38 121. 109. 94.5 79.6 64.6 49.7 34.8 62 118.5 8.52 118. 118. 116. 101. 86.3 71.4 56.5 116.4 9.24 116. 116. 116. 101. 86.6 71.7 56.8 57 115.0 8.50 115. 115. 115. 100. 85.2 70.3 55.3 116.0 9.29 116. 116. 112. 97.1 82.2 67.3 52.4 Outdoor Ambient Temperature 105 °F Outdoor Ambient Temperature 115 °F 3000 72 113.3 10.02 71.2 62.6 54.1 45.5 37.0 - - 107.2 10.74 69.1 60.5 52.0 43.4 34.9 - - 67 106.2 9.85 91.5 82.9 74.4 65.8 57.3 48.7 40.2 98.5 10.44 88.7 80.1 71.6 63.0 54.5 45.9 37.4 62 103.6 9.74 103. 97.2 88.7 80.1 71.6 63.0 54.4 97.8 10.37 97.4 88.9 80.3 71.8 63.2 54.7 46.1 57 103.3 9.75 102. 93.9 85.3 76.8 68.2 59.7 51.1 97.6 10.34 96.2 87.7 79.1 70.6 62.0 53.5 44.9 3500 72 117.0 10.10 78.6 68.5 58.4 48.2 38.1 - - 111.9 10.85 77.2 67.1 57.0 46.8 36.7 - - 67 109.7 9.92 100. 90.4 80.3 70.2 60.1 50.0 39.9 102.8 10.55 97.9 88.5 78.4 68.3 58.2 48.1 38.0 62 107.0 9.81 106. 103. 95.6 85.5 75.4 65.3 55.2 102.1 10.48 101. 97.7 88.0 77.9 67.8 57.7 47.6 57 106.7 9.82 106. 102. 92.1 82.0 71.9 61.8 51.6 101.9 10.45 101. 96.8 86.7 76.6 66.5 56.4 46.3 4000 72 120.7 10.17 86.0 74.3 62.6 51.0 39.3 - - 116.6 10.96 85.3 73.6 61.9 50.3 38.6 - - 67 113.2 9.99 108. 97.9 86.2 74.5 62.9 51.2 39.5 107.1 10.66 107. 96.9 85.3 73.6 61.9 50.3 38.6 62 110.4 9.87 110. 110. 102. 90.9 79.3 67.6 55.9 106.4 10.59 106. 106. 95.7 84.0 72.4 60.7 49.0 57 110.1 9.89 110. 110. 98.8 87.2 75.5 63.8 52.2 106.2 10.56 106. 105. 94.3 82.6 71.0 59.3 47.6 4500 72 121.9 10.22 92.5 79.2 65.9 52.6 39.3 - - 117.9 11.03 92.3 79.1 65.8 52.5 39.2 - - 67 114.3 10.04 112. 103. 90.7 77.4 64.1 50.8 37.5 108.3 10.73 108. 103. 90.6 77.3 64.0 50.7 37.4 62 111.5 9.93 111.5 111.5 107. 94.0 80.7 67.4 54.1 107.7 10.65 107. 107. 101. 88.4 75.1 61.8 48.5 57 111.2 9.94 111.2 111.2 103. 90.6 77.3 64.1 50.8 107.4 10.62 107. 107. 100. 86.9 73.6 60.3 47.0 5000 72 123.1 10.27 99.0 84.1 69.2 54.3 39.3 - - 119.3 11.10 99.4 84.5 69.6 54.7 39.8 - - 67 115.4 10.09 115. 109. 95.2 80.3 65.3 50.4 35.5 109.6 10.79 109. 109. 95.9 81.0 66.1 51.1 36.2 62 112.6 9.98 112. 112. 112. 97.1 82.2 67.3 52.4 108.9 10.72 108. 108. 107. 92.7 77.8 62.9 48.0 57 112.3 9.99 112. 112. 109. 94.1 79.2 64.3 49.4 108.6 10.68 108. 108. 106. 91.1 76.2 61.3 46.4 Outdoor Ambient Temperature 125 °F The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH =3.415 x kW. Refer to the appropriate Blower Performance table i- for the kW of the supply air blower motor. t Input power includes the condenser and compresso motors but not the indoor blower motor. 3000 72 101.1 11.4 67.0 58.5 49.9 41.3 32.8 - 67 90.7 11.0 85.9 77.3 68.8 60.2 51.7 43.1 34.6 62 92.0 11.0 91.4 80.5 72.0 63.4 54.9 46.3 37.8 57 91.8 10.9 90.0 81.5 72.9 64.4 55.8 47.3 38.7 3500 72 106.8 11.6 75.8 65.7 55.6 45.4 35.3 - - 67 95.9 11.2 95.7 86.7 76.6 66.4 56.3 46.2 36.1 62 97.2 11.2 96.9 91.5 80.4 70.3 60.2 50.1 40.0 57 97.0 11.1 96.1 91.7 81.3 71.2 61.1 51.0 40.9 4000 72 112.6 11.8 84.5 72.9 61.2 49.5 37.9 - - 67 101.1 11.3 101. 96.0 84.3 72.7 61.0 49.4 37.7 62 102.5 11.3 102. 102. 88.8 77.1 65.5 53.8 42.1 57 102.2 11.2 102. 101. 89.7 78.1 66.4 54.8 43.1 4500 72 114.0 11.8 92.2 78.9 65.6 52.4 39.1 - - 67 102.4 11.4 102. 102. 90.5 77.2 63.9 50.6 37.3 62 103.8 11.4 103. 103. 96.0 82.7 69.4 56.1 42.9 57 103.5 11.3 103. 103. 96.4 83.1 69.8 56.5 43.2 5000 72 115.4 11.9 99.9 85.0 70.1 55.2 40.3 - - 67 103.7 11.5 103. 103. 96.6 81.7 66.8 51.8 36.9 62 105.1 11.5 105. 105. 103. 88.3 73.4 58.5 43.6 57 104.8 11.4 104. 104. 103. 88.1 73.2 58.2 43.3 TABLE 8: COOLING CAPACITY DF120 (10 TON) UNIT 16 246699 -YTG -B -0606 Unitary Products Group Voltage Compressors OD Fan Motors Supply Blower Motor FLA Pwr Exh Motor Pwr Cony Outlet Electric Heater Model No. Actual KW Heater Amps Min. Circuit Ampacity (Amps) MCA w /Power Exhaust (Amps) 2 HP 3 HP Max Fuse* Size (Amps) 2 HP 3 HP Max Fu w/Power Exhaust (Amps) 2 HP e* Size 3 HP RLA ea. LRA ea. FLA ea. 2 HP 3 HP FLA FLA 2 HP 3 HP 208 16.0 137.0 3.5 8.2 10.9 5.5 0.0 None - - 51.2 53.9 56.7 59.4 60 60 70 70 2TPO4521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70 2TPO4522425 18.0 50.0 72.7 76.1 79.6 83.0 80 80 80 90 2TPO4523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110 2TPO4525425 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175 230 16.0 137.0 3.5 8.2 10.9 5.5 0.0 None - - 51.2 53.9 56.7 59.4 60 60 70 70 2TPO4521825 18.0 43.3 64.4 67.8 71.3 74.6 70 70 80 80 2TPO4522425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100 2TPO4523625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125 2TPO4525425 54.0 129.9 140.2 143.5 147.0 150.4 150 175 175 175 460 8.3 69.0 1.6 4.1 5.3 2.2 0.0 None - - 26 27.2 28.2 29.4 30 35 35 35 2TPO4521846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40 2TPO4522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50 2TPO4523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70 2TPO4525446 54 67.8 70.1 71.6 72.8 74.3 80 80 80 80 575 6.4 58.0 1.3 3.6 4.1 1.8 0.0 None - - 20.6 21.1 22.4 22.9 25 25 25 25 2TPO4521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30 2TPO4522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40 2TPO4523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50 2TPO4525458 54 54.2 56.5 57.1 58.7 59.3 70 70 70 70 • Maximum HACR breaker of the same AMP size is aoolicable. Voltage Compressors OD Fan Motors Supply Blower Motor FLA Pwr Exh Motor Pwr Cony Outlet Electric Heater Model No. Actual KW Heater Amps Min. Circuit Ampacity (Amps) MCA w /Power Exhaust (Amps) 2 HP 3 HP Max Fuse* Size (Amps) 2 HP 3 HP Max Fuse w /Power Exhaust (Amps) 2 HP Size 3 HP RLA ea. LRA ea. FLA ea. 2 HP 3 HP FLA FLA 2 HP 3 HP 208 16.0 137.0 3.5 8.2 10.9 5.5 10.0 None - - 61.2 63.9 66.7 69.4 70 70 80 80 2TPO4521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80 2TPO4522425 18.0 50.0 85.2 88.6 92.1 95.5 90 90 100 100 2TPO4523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125 2TPO4525425 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175 230 16.0 137.0 3.5 8.2 10.9 5.5 10.0 None - - 61.2 63.9 66.7 69.4 70 70 80 80 2TPO4521825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90 2TPO4522425 24.0 57.7 94.9 98.3 101.8 105.2 100 100 110 110 2TPO4523625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150 2TPO4525425 54.0 129.9 152.7 156.0 159.5 162.9 175 175 175 175 460 8.3 69.0 1.6 4.1 5.3 2.2 5.0 None - - 31 32.2 33.2 34.4 35 40 40 40 2TPO4521846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45 2TPO4522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60 2TPO4523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70 2TPO4525446 54 67.8 76.3 77.8 79.1 80.6 90 90 90 90 575 6.4 58.0 1.3 3.6 4.1 1.8 4.0 None - - 24.6 25.1 26.4 26.9 30 30 30 30 2TPO4521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35 2TPO4522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45 2TPO4523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60 2TPO4525458 54 54.2 61.5 62.1 63.7 64.3 70 70 70 70 Maximum HACR breaker of the same AMP size is aoolicable. 246699 -YTG -B -0606 TABLE 15: ELECTRICAL DATA DF120 (10 TON) MID EFFICIENCY W/O PWRD CONVENIENCE OUTLET TABLE 16: ELECTRICAL DATA DF120 (10 TON) MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET 20 Unitary Products Group Model Location (lbs.) A B C D DF078 231 197 288 337 DF090 195 146 228 306 DF102 197 147 230 309 DF120 260 222 324 379 Model Locations (lbs.) A B C D E F DF078 158 142 128 187 207 231 DF090 137 112 93 145 175 214 DF102 138 113 93 146 176 216 DF120 178 160 144 210 233 260 Model Shipping' Weight (lbs.) Operating Weight (lbs.) DF078 1058 1053 DF090 875 870 DF102 888 883 DF120 1190 1185 ECON. 85 84 PE 150 148 GAS HEATt 110 100 ELEC. HEAT* 49 49 Unit Model Number X Y DF078 471/2 251/2 DF090 38 23 13F102 38 23 DF120 471/2 251/2 FIGURE 2 - UNIT 4 POINT LOAD TABLE 31:4 POINT LOAD WEIGHT Weights include largest heating option. FIGURE 3 - UNIT CENTER OF GRAVITY FIGURE 4 - UNIT 6 POINT LOAD TABLE 32:6 POINT LOAD WEIGHT 246699 - YTG - B - 0606 TABLE 33: UNIT WEIGHT Weights include largest heating option. t 8 tube gas section. # 54kW heater. 32 Unitary Products Group Unit Model Number X DF078 50 3/4 DF090 42 DF102 42 DF120 50 3/4 Top 72" Right 12' Front 36" Left 36' Reart 36' Bottom* 0' 246699 -YTG -B -0606 FIGURE 5 - UNIT DIMENSIONS TABLE 34: UNIT HEIGHT DETAIL A s_v4 Gas Pipe Inlet View of Wall Across from Coil TABLE 35: UNIT CLEARANCES • Units must be installed outdoors. Overhanging structure or shrubs should not obstruct condenser air discharge outlet. t To remove the slide -out drain pan, a rear clearance of 60" is required. If space is unavailable, the drain pan can be removed through the front by separating the corner wall. t Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. DETAIL B DETAIL C See Detail A For Baserail Dimensions See Detail B Unitary Products Group 33 FIGURE 6 - PREDATOR ROOF CURB DIMENSIONS 2 TYP INSULATED DECK UNDER COMPRESSOR SECTION FRONT FRONT RIGHT 64-1/4 FIGURE 7 - SUNLINETM TO PREDATOR TRANSITION ROOF CURBS RIGHT 246699 -YTG -B -0606 INSULATED DECK UNDER CONDENSER SECTION 34 Unitary Products Group 246699 -YTG -B -0606 REAR DUCT DIMENSIONS CABINET SIZE 50 3/4" 42' Unitary Products Group 6.13/16 LEFT I 19-3/16 1 21.3116 17.3/16 11 4- 14-23/32 4— 16.3/8 32. 11116 —ai 6-13/16 4-1 RETURN MR ..A,. 28 1/4 27 3/4 DIMENSION „ 18 1/16 12 1/16 " 28 1/4 27 1/2 FIGURE 9 - REAR DUCT DIMENSIONS 27 -1/2 r Bottom Power, Control and Convenience Outlet Wiring 5-5/32 SUPPLY MR 21 1 4 1 1 FIGURE 8 - BOTTOM DUCT OPENINGS (FROM ABOVE) FRONT 6 - 13/16 Bottom gas supply entry I 12 -5116 35 TABLE 36: ECONOMIZER USAGE Application Cabinet Height Description Model Bottom Return All Downflow economizer with barometric relief 2EE04705424 Side Return All Horizontal economizer without barometric relief 2EE04705524 ERV or End Return 42" Slab Economizer, 42" tall cabinet 2EE04705624 50" Slab Economizer, 50" tall cabinet 2EE04705224t 36 39 1/2 or 47 1/2 Outside Air Intake Hood 35 3/4 58 1/4 N 26 25 3/4 FIGURE 10 - DOWNFLOW ECONOMIZER HOOD DETAIL 88 1/4 26 • Barometric relief must be ordered seperately and installed in duct work. t Barometric relief or fresh air hood not included. Must be ordered seperately. 30 1/4 246699 -YTG -B -0606 Relief Hood for Power Exhaust or Barometric Relief Unitary Products Group 246699 -YTG -B -0606 2EE04705424 2EE04705424 2EE04705424 Fresh Air Hood Fresh Air Damper Return Air Damper 2EE04705424 Barometric Relief Damper FIGURE 11 - FACTORY INSTALLED DOWNFLOW ECONOMIZER 2EE04705424 2EE04705424 2EE04705424 2PE047032XX Fresh Air Hood Fresh Air Damper Retum Air Damper Power Exhaust 2EE04705424 Barometric Relief Damper FIGURE 12 - FIELD INSTALLED DOWNFLOW ECONOMIZER W /POWER EXHAUST 2EE04705424 Barometric Relief Hood 2EE04705424 Barometric Relief Hood Unitary Products Group 37 01 -08 -2008 GARY WIRTA P O BOX 82360 KENMORE WA 98028 RE: Permit No. M07 -161 1185 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 02/06/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, OkA93 fer Marshall Permit Technician xc: Permit File No. M07 -161 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M07 -161 DATE: 07 -20 -07 PROJECT NAME: DANNY FURNITURE SITE ADDRESS: 1181 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bu In 00Msion ii()1 Public Works ❑ ` PERMIT COORD COPY `' PLAN REVIEW /ROUTING SLIP t5 l( M l � Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28 -02 Incomplete Structural Review Required Planning Division ❑ Permit Coordinator DUE DATE: 07 -24 -07 Not Applicable Comments: ❑ No further Review Required REVIEWER'S INITIALS: DATE: Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: APPROVALS OR CORRECTIONS: DUE DATE: 08 -21 -07 Approved ❑ Approved with Conditions 11.4 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License CFMHEHC969CD Licensee Name C F M HEATING AND COOLING INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602361244 Ind. Ins. Account Id #1 Business Type CORPORATION Address 1 PO BOX 82360 Address 2 City KENMORE County KING State WA Zip 98028 Phone 4254816239 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/4 /2004 Expiration Date 2/4 /2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 RLI INS CO SRS1008639 02/04/2004 Until Cancelled $12,000.00 02/04/2004 Business Owner Information Name Role Effective Date Expiration Date CLANCY, SHAUN PRESIDENT 02/04/2004 Sue Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Savings Information https: // fortress. wa. gov /lnilbbip /printer.aspx ?License= CFMHEHC969CD 08/10/2007 MIXED -USE, NON-SEPARATED USES (SECTION 507): TYPE OF CONSTRUCTION: III -B (FULLY SPRINKLED) 507.3 TWO STORY. BUILDING IS SURROUNDED BY 60' OPEN SPACE ALL SIDES. (B,S,M USES) BUILDING AND SITE STATISTICS: BUILDING CODE: IBC 2003 W/ WA STATE AMENDMENTS ZONING: TUC (TUKWILA URBAN CENTER) SITE AREA: APPROX. 215,015 S.F. (4.94 AC) EXISTING BLDG. 107,660 S.F. (OFFICE 9,689.4;, WHSE 97,970.6;) TENANT SPACE: 15,935 S.F. OFFICE: 320 S.F. RETAIL: STOCKROOM OCCUPANCY GROUPS AND LOADS: B (OFFICE) 320 S.F. M (RETAIL) 12,342 S.F. S -1 (STOCKROOM) 3,273 S.F. TOTAL OCCUPANTS = 3 EXITS SHOWN (108" WIDTH) TYPE OF CONSTRUCTION: III -B (FULLY SPRINKLERED) PARKING REQUIRED PARKING :OVERALL BUILDING OFFICE: 8,318.4 S.F.@ 3.0/1000 = 25.0 SPACES RETAIL 26,989 S.F. @ 2.5/1000 = 67.5 SPACES WHSE.: 71,214 S.':'' 1.0/2000 =35.6 SPACES 128 SPACES REQD. PARKING SPACES PROVIDED 125 EXISTING PARKING SPACES (NO CHANGE) ADD 5 STALLS, TOTAL 130 STALLS ENERGY CODE NOTES: 1. CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER- STRIPPING AT ALL EXTERIOR DOORS AND WINDOWS. 2. NEW STOREFRONT IS ALUMINUM FRAME W /THERMAL BREAK AND 1" OVERALL CLEAR INSULATED GLAZING WITH 1/2" AIR SPACE (U =0.55 AND SHGC = 0.45). 3. HEAT IS VIA GAS, NO ELECTRIC ALLOWED. 4. MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP. CIRCUIT. 5. ALL LIGHTING SHALL BE TESTED, CALIBRATED, AND ADJUSTED TO OPERATE WITH ACCORDANCE WITH APPROVED PLANS. COMMISSIONING SHALL BE IN ACCORDANCE WITH 2003 WSEC 1513.7 WITH TEST RESULTS FILED WITH THE OWNER. 6. OCCUPANCY SENSORS ARE REQUIRED IN OFFICE SPACES LESS THAN 300 S.F. AND ALL MEETING AND CONFERENCE ROOMS COMPLYING WITH WSEC SECTION 1513.6.1 7. DAYLIGHTING MUST COMPLY WITH WSEC 1513.3 AND CHAPTER 2. 0 / 100 = / 30 = / 500 = 12,342 S.F. 3,273 S.F. 3 OCCUPANTS 411 OCCUPANTS 6 OCCUPANTS 420 OCCUPANTS (2 EXITS, 63 INCHES) $ irrTSi39`VV i ANDOVER PARK WEST SCOPE OF WORK: INSTALL NEW H.C. RAMP AT MAIN ENTRY, ADD WALL INSULATION TO ALL WALLS, INSULATE OVERHEAD DOORS, ADD REAR EXIT W /AREA OF EVACUATION ASSISTANCE AND ASPHALT WALKWAY PREVIOUS USE WAS BULK RETAIL AS IS THIS USE OWNER CALWAEST INDUSTRIAL HOLDINGS LLC C/0 RREEF CORP. 1 000 CHRISTENSEN ROAD SUITE 101 TUKWILA, WA 98188 PH: 206.241.1028 FX: 206.241.7512 ASSESSOR PARCEL NUN 3523049093 LEGAL DESCRIPTION PARCEL B: BER THAT PORTION OF THE SOUTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 26, AND THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 35, ALL IN TOWNSHIP 23 NORTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHEAST CORNER OF SAID NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 35; THENCE NORTH 87 44' 08" WEST ALONG THE NORTH LINE OF SAID NORTHWEST QUARTER OF THE NORTHEAST QUARTER A DISTANCE OF 30.00 FEET TO THE WEST MARGIN OF ANDOVER PARK WEST, AND THE TRUE POINT OF BEGINNING; THENCE SOUTH Or 51' 39" WEST ALONG SAID WEST MARGIN A DISTANCE OF 681.34 FEET; THENCE NORTH 87' 55' 02" WEST A DISTANCE OF 270.00 FEET; THENCE NORTH 01' 51' 39" EAST A DISTANCE OF 682.20 FEET; THENCE NORTH 0V 47' 29" EAST A DISTANCE OF 114.81 FEET; THENCE SOUTH 8T 55' 02" EAST A DISTANCE OF 270.00 FEET TO THE WEST MARGIN OF ANDOVER PARK WEST; THENCE SOUTH 01' 47' 29" WEST ALONG SAID WEST MARGIN A DISTANCE OF 115.66 FEET TO THE TRUE POINT OF BEGINNING; TOGETHER WITH A NON - EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS OVER A STRIP OF LAND 25 FEET IN WIDTH ADJACENT TO AND NORTHERLY OF THE NORTH LINE OF THE PROPERTY HEREIN DESCRIBED; AND TOGETHER WITH A NON- EXCLUSIVE EASEMENT OVER A STRIP OF LAND 50.00 FEET IN WIDTH ADJACENT TO AND SOUTHERLY OF THE SOUTH LINE OF THE PROPERTY HEREIN DESCRIBED. 737.1' IIINPIriCMAiLIMl.01l1101 l�l�lrlrl�l�I�Irl�l�l�l�l�l�Irl�l `I�Irl�l - -- -- - - -- - - -- -- - - _�. �i�l�l�iii�lr�lr�lii�iilr ■inr�ii�riirli��i 0 r n SITE PLAN SCALE= r . 47-0" (PUBLIC) VD. cod ST frA VICINITY MAP Nv scALF: N.T2. KEY SITE PLAN sCALS N.rs. BLDG E BLDG D BLDG C BLDG B ANDOVER PARK WEST s1#472VW 15:68 a r►; m BUILDING. A (96,165 ± SQ.FT.) MULTIPLE BUSINESSES 1179, 1181, 1183, 1185, 1187, 1189, 1191 ANDOVER PARK WEST TUKWILA, WASHINGTON 'CO= NEW EXTERNAL STAIR S 0747'29' W 11481' 110llllllam, %%%%%%%%%%%%%%% . • • • • . . . • . • S. • • • NEW ASPHALT PATH TO STREET (NORTH) (4') 09' " " NEW STRIPING D NEW PARKING STALLS M.C. 0 REVISIONS No of work shall be mad@ to the scope N Tukwila Building � approval of Revisions will require Division. and may include additional mqu p ��at tees. FILE COPY Permit No. Pan review cpproval is subject to errors and omisstoria Approval of constuction documents does not authortlz the violation c f any accepted code or ordinanCe. Receipt of approvc:l F, c: l Copy and cond :tions is acknoo vledgeda BY 8-10 -07 City of Tukwila BUILDING DIVISION EX 1 SET DATE: 07 -19 -07 FEB 0 6 2008 REVIEWED FOR CODE COMPLIANCE APPROVED AUG - 9 2007 City O kaviia BUILDING DIVISION O1a ((ol RECEIVEI JUL 202007 PERMIT CENT E, 1 CONTRACTORS LICENSE CFMMEHC969CD IL I J 0 CONCENTRIC SUPPLY DIFFUSER CONNECTED TO BOTTOM OF DROPS TYPICAL OF 2 114 RETURN AIR GRILLE LOCATED HIGH ON RETURN DROP TYPICAL OF 2 A (ON ROOF) AC HVAC FLOOR PLAN SCALE:1 /8" = 1 '0" North z a E X P 1 FEB 0 6 Z008 ECE-REE JUL 20 2007 PERMIT CENTE- SET DATE: 07-19-07 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 9 2007 City Of Tukwila BUILDING DIVISJON SHEET NUMBER 1. § a) 0 0 0 H o O w 06 CC < CC 0 _ I-- CC Z CC 0 D 0 LL < Z < Z y • < D o u_ M1 .0 CONTRACTORS UCENSE CFMHEHC969CD >- m