Loading...
HomeMy WebLinkAboutPermit M07-168 - NC MACHINERYN C MACHINERY 17025 WEST VALLEY HY M07 -168 Parcel No.: 2523049046 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: 17025 WEST VALLEY HY TUKW Contractor: Name: MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU DESCRIPTION OF WORK: INSTALL 1 NEW ROOF TOP EXHAUST FAN AND MAKE UP AIR DUCT Value of Mechanical: $15,104.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10 /06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us N C MACHINERY 17025 WEST VALLEY HY , TUKWILA WA HARNISH GROUP INC 17035 W VALLEY HWY , TUKWILA WA NASH PATWARDHAN 7717 DETROIT AVE SW , SEATTLE WA MECHANICAL PERMIT Fees Collected: $338.73 International Mechanical Code Edition: 2006 EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M07 -168 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 -768 -4128 Phone: 206 -763 -9400 Expiration Date: 12/31/2008 M07 -168 08/03/2007 01/30/2008 Boiler Compressor: 0 -3 HP /100,000 BTU 3-15 HP /500,000 BTU 15-30 HP /1,000,000 BTU.. 30-50 HP /1,750,000 BTU.. 50+ HP /1,750,000 BTU Fire Damper Diffuser Thermostat Wood/Gas Stove Water Heater Emergency Generator Other Mechanical Equipment 0 0 0 0 0 0 0 0 0 0 0 0 Printed: 08-03 -2007 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction ore performance � of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: IMC-10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 4 9 - 14 s-e___ Permit Number: M07 -168 Issue Date: 08/03/2007 Permit Expires On: 01/30/2008 " Rani Date: 1 7 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -168 Printed: 08 -03 -2007 Parcel No.: 2523049046 Address: Suite No: Tenant: N C MACHINERY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17025 WEST VALLEY HY TUKW PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: M07 -168 ISSUED 07/30/2007 08/03/2007 M07 - 168 Printed: 08-03 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 0 /63/607 Date: M07 -168 Printed: 08 -03 -2007 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Site Address:A 1 ` 5 to + Al 1 ' 1v Tenant Name: "C in Ccd (/1 1 - ■ Property Owners Name: 1 e l\ A Mailing Address: 11 a S W t-SA" Val (Pe i Name: 9k,\ oC -I"Ia 0 hAv. Mailing Address: "') 11 1 —k, ' Q i+ JR. S L.) E -Mail Address: GENERAL CONTRACTOR INFORMATION (Contractor tion for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: ARCHITECT OF iffeOR) Q \Applications\Fotms- Applications On Line3-2006 - Permit Application.doc Revised: 4-2006 bh Mailing Address: Building Permit No. Mechanical Permit No. MO -7 - 1(Pe Plumbing/Gas Permit No. Public Works Permit No. Project No. For office use only) '! Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 5 "")._3 O 4 g Q 4 jWuite NumberRo Floor: V....6 New Tenant: ❑ Yes i' I.No City CONTACT PERSON S -c..)s w A City State City Contact Person: 11 a • - . one: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: must be wet st amped by Architect of Record 1^- State State clPi Zi p Day Telephone ..( - 1427 " 'il 29 C 17/0G Zip Fax Number: Zip Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: 1 1/10. C V O na-k t4 RA L L&r Mailing Address: - 7 ' 1 1 ''S:44-.A ✓o C 4J S.Ceek t..4 c\1 1 0 t City State Zip Contact Person: 0 v J - 17.) , ( - 142.", Day Telephone: Tom) 7 (c - '5 LTD E -Mail Address: Fax Number: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION , Company Name: 64 OA.CD 0 (1...0,l d in t Mailing Address: —] 1 I 1 "Qe.kr*O \ .k City State Zip 0:5 Contact Person: \ V � YN_ QUL., � 0.4, Day Telephone: (. ) - AA - 4921 E -Mail Address: Fax Number: Contractor Registration Number: F 2A.C.DO F S °1 C3Q Expiration Date: la - 3) - 0 Valuation of Project (contractor's bid price): $ 47 15, IQ ` f - Scope of Work (please provide detailed information): � in5 ` \ ( tt-_ kip n p e akAoT Fa,,n Oa\ k mo. - - c &i C`► r alu v� Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ..)Sk Replacement .... ❑ Fuel Type: Electric .\ &1 . Gas ....p Other: Indicate type of mechanical work being installed and the quantity below: Q:\Applications\Forms- Applications On LineV3 -2006 - Permit Application.doc Revised: 4 -2006 bh 1 91 to Page 4 of 6 • V•' PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OR AUTHORIZED A '� Signature Print Name: A 2-va o Mailing Address: Y7 / �) TD--ekr - 6 Cfi �c �LJ Q:Wpplications\Fomts- Applications On Line'3 -2006 - Permit Application.doc Revised: 4 -2006 bh Date: '7 a 7 - O Day Telephone: ��c) 7 g s rN� 42 /0b City State Zip Date Application Accepted: 7 30- Date Application Expires: 1- 30-0)8 Staff Initials: 4 4 Page 6 of 6 Parcel No.: 2523049046 Permit Number: M07 -168 Address: 17025 WEST VALLEY HY TUKW Status: PENDING Suite No: Applied Date: 07/30/2007 Applicant: N C MACHINERY Issue Date: Receipt No.: R07 -01515 Initials: WER Payment Date: 07/30/2007 10:40 AM User ID: 1655 Balance: $0.00 Payee: MACDONALD MILLER City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 1362 338.73 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000/322.100 276.98 000/345.830 61.75 Total: $338.73 Payment Amount: $338.73 0836 07/30 0710 TOTAL 482.73 doc: Receipt-06 Printed: 07 -30 -2007 Proje t: // I /,v(/9 Type of Inspection: / - /.0 .1/ Address: /7425 7J (i,e// Date Called: Special Instructions: Date wanted: S - 3/ -0 f m. Requester: Phone No: INSPECTION RECORD J l Retain a copy with permit its INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ll& 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspecto $ (Receipt No.: 4,142/ ,.., • ■ _._ R ,. _.. 'Date: � ,71 / / // - .00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be Id at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. ACTIVITY NUMBER: M07 -168 DATE: 07 -30 -07 PROJECT NAME: N C MACHINERY - DYNO ROOM SITE ADDRESS: 17025 WEST VALLEY HY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: = ul (• ing' Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Please Route PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP TUES/THURS RQUTING: III kik1 1 Fire Prevention Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required Planning Division DUE DATE: 07 -31 -07 Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: IK El DUE DATE: 08 -28 -07 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company Previous License DIVCOI *988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SIGMUND, FREDRIC PRESIDENT 12/31/2002 KOPET, TYLER SECRETARY 12/31/2002 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 r -- ---- -- - ---- - Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. I, . Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress. wa. gov /Ini/bbip /printer.aspx ?License= MACDOFS980RU 08/03/2007 r • • s 0 i i i L iirf '... rasamr.. NBF MAI/AVMAIIW.dr.Wii :��ar,Ivi��►iMA/Ar rAllrWiiiAriAIAIIIiiiiiAIiArff IPWAPW M,q.ri/.IAV4yfAr .. i i 1 • .-' ri 0 • • I f z roarm /��ir■f>1Lff7//! mili 12x to ORM'.66OCFP1 TeRMnnATF IS"AFF i 0 DY rt o ROOM © 22a- MAKE -UP Adz INTAKE PROP Mom TNF Rte. W/BDP 1 70 EF -1 !_ SHEET . I 01 ()EXHAUST FAN EF-f T_STAT. PIy 'DET, 2 ROOFING 8y G.C QMAIcE -tQ A!R INTAKE EXHAvzsT aPENIF'GS FIELD To (Xi. IKE 0 IrISTALL 18r IS Exit 0c Tit H RRu c1 H 2O '/2 x /0 ' ix ROOF OPEN I NFi . 1Nl 9DD 0 12 10 DRo? 66oCfM `TERI4INAte 6 =O OFF 024 4 1 RoU.ED By U NE VOLTAGE ins sy M-M. SET PoiNT 7B MGT To BE LOcA1ED 'O=o' AWAY FROM Arty rct STALL A GO4SEr4ECK FiTttcif . ''tT # . - pit_11 €, Rao SEE 'DE'TAIL 1 /71110 -01 voLuME DAMPERS • I1s 5ftaw,� EMEAMCE To 660 ttM E7+Ctt • 1 rq 0 • • 0, t3 I • • i • • • • • li 1 1 • 1 1 • • .L_ c L. MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206.763.9400 Fax: 2064674713 www.macmiller.com WA Llc No: MACDOFS980RU NC MALI -Y WELD DYNO ROOM EXHAUST 17025 WEST VALLEY HWY IUCWI A WA 98188 1ST FLOOR PENN - HVAC w 8 GrZON rs WIC 100111! 1 1E> 07 -06-07 I wwc wa O -11ii- 7376517 -4o I5SIJE1) FOR CONSTRUCT 1ON UM WM 0? 21111 MOM 07 SINE 01-25- TM2.01 • 1 r • • • ... N:1 pi 24 2'. OSA TAKE w /6005Eti ECK. F117IMG, WrrH A 2t6c24 GIRAY2'1? Divieeg (B9-1), SEE DETAIL tfTMO.OI 220 DR P TO Dy No Rom • 0 F% -I A 0 SSEET r011ES: 0 24rig2A mA 1s TAKE wieRAv TY DU1t'iffit_ GOOSES F:tl"IG - SEE ()ETA IL sh AO- 0L FIELD VER■FY "MAT THE l 4TA cg 15 * _tE<sT toto _ AWL*, FRon Atry exK .6T oVENK, To MEET s'IC FAN EF -t t*STAI rt9 ON FACTORY SUM:ED CuP 81 141. RROFI G aY Cz-C - net* 7c IN .: Att O's< CcT' S•tTOt ,Jr tei Tim SIGHT OF Trge F/W • —® MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206.763.9400 Fax: 206.7676773 www.macmillercom WA LIc No: MACDOFS980RU 1 EXPIRE : 07 -06-07 I CO /PER IT ISSO E ttp 07- NC MACHFERY WELD DYNO ROOM EXHAUST 17025 WEST VALLEY HWY fl1(WLA, WA 88188 ROOF PARTIAL PLAN - HVAC OoER us. sem ,1 PATWaDIWI 0725 -o MUG) se s4 Ras. B CEZCN 07 -25-07- es sum ark N WOOER 07 -25-01 ems nowt I?- 1111- 73765i7 -00 ISSUED FOR CONSTRUCT' ON 31116 e TM2.02 OWE 6 1 EXHAUST FAN SCHEDULE UNIT NO. AREA SERVED MFG & MODEL NO. TYPE CFM ESP RPM HP VOLTIPH BOD WT LB8 NOTES EF-1 DYNO ROOM ORES NHECK 0-1608 CEMRIFUGAL ROOFTOP 1980 0.5 1140 1R 11511 YES 100 NEW, 1. 2, 3, 4 COUNTER - BALANCED BACKDRAFT DAMPER SCHEDULE UNIT NO. MANUFACTURER MODEL NO. SIZE MOUNTING POSITION AIRFLOW WT LOS NOTES BO0-1 RUSKINC80 -2 24'x24' HORIZONTAL VERTICAL NEW 1.2 r • ZIZSAVIIS I r •J:asr S! :S0D8S3u 0 Z • • isnoisays i tKY1Tl R "ton I 1 1 t NOTES: 1. POWER WIRING1 NEMA3R DISCONNECT BYE.C_ 2. ME MM TO INSTALL FAN ON A FACTORY SUPPUEO CURS WITH SCREENEO DROP NE BACKDRAFT DAMPER IN THE CURB ROOF CUTTING NE PATCHING BYG.C. 3. FM CONTROLLED BY LNE VOLTAGE TSTAT PROVIDED AND INSTALLED BY MK TSTAT SET PORT TO BE 78 003 F. 4. DIRECT DRIVE FAN 1. GRAVITY DAWWER AT THE OUTSIDE AMR INTAKE IN ORDER TO MEET WSEC 1412,4.1 EXCEPTION (3) 2 ROOF CUTTING Nr, PATCHING BY RD SCOPE OF WORK PROVIDE & INSTALL (1) ROOF TOP EXHAUST FAIL PROVIDE AND INSTALL MN -UPAR DUCT FROM THE ROOF WITH AG006ENECK INTAKE AS DETAIL PROVIDE & INSTALL DISCONNECT AND ELECTRICAL WING FORME FAN. PROVIDE AND INSTALL/ LIRE VOLTAGE TSTAT. GOOSENECK TYPE AIR INTAKE DETAIL 11.t‘ IM\UM7 A, CRT MK SOUNDLNNG BIRD SCREEN gliEEK_VES; 1) was D = ROOF OPENING 2) FRI& RESP0 S CURS SIZE RY FOR CORRECT CURB A BOO SIZES EQUIPMENT 1ILL BE INSTAl1IRS. EXHAUST FAN INSTALLATION DETAIL NO SCALE 1 ABASIONS No changes shall beandsbsloescope else* cveaB ��d NOTE: #Ie+It4o n t,ingli lla aaLaAiBM nsbwMal and animal plemilseless I • • HVAC GENERAL NOTES S. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WINCH MAYBE REQUIRED. THE HVAC FOREMEN IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK 2. MATERIALS. METHODS AND INSTALLATON SHALL COMPLY WITH THE PROVISIONS OF THE 2003 EDITIONS OF THE INTERNATIONAL MECHANICAL. CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCH. COOES NM°ROMANGES. 3. DUCT CONSTRUCTION AND HANGING SHAT COMPLY WITH CHAPTER 8 OF THE 2004 AMC AND WITH CURRENTSMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28' DIA MID LARGER WHICH ARE SUSPENDED MORE THAN ST BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY OUCT SYSTEMS SMALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATE) AS INDICATED ON PLANS, PER 2004 WSEC. - DUCT WRAP, WHERE INDICATED. SHALL BE 2.0' 0.6 LBW FT FIBERGLASS DUCT INSULATION WITH AFACTORY APPLIED REBNRIRCED MUM. FOIL VAPOR BARRIER (R-3.3 MN.). - SOUND LUNG. WHERE INDICATED. SHALL BE 1' 1.5181CU FT FIBERGLASS DUCT LINING COATED 70 PREVENT FIBER EROSION AT VELOCITIES UP TO 4000 FPM (R.1.3 MN.). - DUCT BOARD, WHERE INDICATED. SHALL BE V RIGID FRK FACED El 475 FIBERGLASS DUCT BOND SYSTEM. UL 181 MEDASA CLASS 1 AIR DUCT (R4.3 MW.} 6. FLEX DUCTS SHALL CONSIST OF A RENFORCEO VAPOR BARRIER. 1 UT FIBERGLASS INSULATION. AND NON - PERFORATED INTERIOR LNF3t WITH WIRE HEI.00 DUCT S H A L L BE A UL 181 L I S T E D C L A S S 1 AR DUCT. FLEX D U C T S SHALL ONLY BE USED WHERE SHOWN A D SHALL Nor EXCEED e N LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT N ACCORDANCE WITH SECTION 1821 OF THE 2003 IBC. 8. P R O V I D E F I R E DAMPERS. SMOKE DAMPERS MID FIE/SMOKE DAMPERS WHERE I N D I C A T E D ON PLANS MIDAS REQUIRED BY SECTION 7165OF THE 2003IHC PROVIDE CEIJNG FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.62OF THE 2004 BC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FREI$MOKE DAMPERS N ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. THE TERMS OF TIER USING, AND THE REQUIREMENTS OF THE CODE. a PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH USTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10.PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING. 000LNG, OR VEINTILJATON EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 608 OF THE 2003 INC. POWER AND INTERLOCK WIRING WITH THE/WILDING FRE ALARM SYSTEM IS BY THE ELECTRICAL. CONTRACTOR 11.HVAC EQUIPMENT, VALVES AND OAAPERS SHALL BE LOCATED IN EASILY ACCESSMSLE LOCATIONS. UNLESS SHOWN ON ARcHREC1UR L CRAVINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 12.HEAT TRACING OF PWING„ WHERE INDICATED. SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR THE HVAC CONTRACTOR RACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH THE ELECTRICAL CONTRACTOR 1&MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR 14.11111111111 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE. RECORD DRAWINGS OF THEACTWL INSTA.LATON TO BE PROVMOE)TOTIE BALDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MN W.UM THE LOCATION AND PERFORMANCE DATAON EACH PIECE OF EQUIPMIENNT. GENERA. CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL MR AND WATER DESKNN FLOW RATES. 15.OPERATNG AND MAIiTTENANGE MANUALS TO BE PROVIDED TO THE BUAONG OWNER THAT INCLUDE: SUBMITTAL DATA. NAMES AND ADD OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION MD ACOMPLETE OPERATONAI NARRATIVE FOR EACH SYSTEM. 1&COMIASSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC)SECTION 1416 ANDWI /I LELD NC-21 FUNMMBYTAL BUILDING SYSTEMS COMPASSION ING MD ADDITIONAL 00 0(NNG. 17.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OMER I8.DAkPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR REEF SHALL HAVE THE FOLLOW /4G MAXIMA LEAKAGE WATESAT 1` W.G. (PER AiICASTNCIPMD 50(t MOTORIZED DAMPER& 10 CFMIS.F. GRAVITY DAMPERS` 20 CFLARSF (40 CFM RS.F FOR DAMPERS SMALLER THAN 24 INCHES IN ELHERDIMENSION). 19-OUTSIDE AR INTAKE. EXHAJST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES !MST BE MOTORIZED FAIL CLOSED) PER WSEC 14124.1. EXCEPT AS ALLOWED BY WSEC. ABBY A AC AFF AL 800 B OB B OO BOTT BTU BTRRI BNG W W1 C CAP CC: C M CHAR CHAS COMB CONN CRS CWS OB OFF OMPR ON EC EGC E6t B EV EMS FULL NAME NAME TITLE APR 8 Pesnittr Cdr Of TLkc3a etADING DIVISION OOIIPRESSE0ALRERIE AIR OONDITDNING ABOVE FLASHED FLOOR AUNAMAI BACKDRAFT DAMPER B OTTOM OF BEAM B OTTOM OF DUCT BOTTOM B RITISH THERMAL UNITS B RITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONIEROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATE;RRETURN OILEDWATERSUPPLY COKTKON CONDEKSERWATE3R RETURN CONDENSER WATER SUPPLY DUCT BOARD B FFUS'ER DAMPER OWN BECTRI AL OONTRACIOR EGGCRATE ENERGY EFFICIENCY RATIO EEEVATION ENERGY MANAGEMENT SYSf ai TIM M SCHEDULES & NOTES - WPC TIt201 1ST FLOOR PARTIAL PLAN -HVAC NJw fiRMN si7r041 sutlJoL" b arras a Ayr b$ CI cs , _aion 600a-rt &' r LL's V 'dOr: C.' . a0 . i CSC Q NDr'la! - d 3 C.:7! r a j % C.._'' t ELF 1 Deft c 4 c 311,' = ABBY FULL NAPE ESP E 1 EXTR FAC FO RA FOB FOT FSD G GALV GC GPM GR GRIT HG HP HMS INT LLQ L4M MBH MC MCA MD MIN MKT MIUA IROII 1 HVAC ABBREVIATIONS EXTERNAL STATIC PRESSURE EXHAUST EXTIVC/OR ME ALARM CONTRACTOR FIRE DAMPER FULL LOADMPS FLAT ON BOTTOM RAT ONTOP FIE SMOKE WAFER GAMINE GALVINITZELI GENERAL CONTRACTOR GALLONS PERMUTE GRILLE GYPSUM WALL BOARD NOT GAS LINE NORSE POWER HOT IVATERRETRXRN HOT WAATERSU PFLY WSDE DIMENSION IIHERLOQC LIQUID LIE MACDONALDMIER ONE THOUSAND BMI MER'ANICIL CONTRACTOR UMW CEICUTALPACTY MOIORQND DAMPER MAMA MOUNT MAE4)PAR NORMAL AREA OF IKCRX DRAWING SHEET INDEX NAME TITLE ABBY FULL NAME OSA OBD 00 RA REG MOD RIO SA SCO SD SL SY SP SS SESC S. SUC SUSP 71202 ROOF PARTIAL PLN4 _HIVJD CONTACT UST NAME COMPANY PHONE MISER FAX NUMBER PROJECT 6IGYrEBt ACCOUNT MECUM* SHEET METAL FORMAN FEW ENGINEERING C NTRMXS KASHA PAIWAREIHAN KEVIN WILDER EDAM/ HARBISON MAD SHARP MICE McGIVERN MACOONALDMI IER MACEIONALDMtMfR IMACDONALDIKIER WM OONPADM IER MNCOONALD M UER 206-7684128 2067684128 253610.3103 2067684294 2061684112 206-768-4046 LEGAL DESCRIPTION LEGAL OESCR P OPL 8230446 PORTION OF VE S ff LOT6IKTHESOUTi1YHESTOUA47TEROFSECTION252304L11ING1EESTERLYOFSTATEHIQAIOAYNOSMLESS NORTH 2O0FT CcEIVI I.'ME WEST VALLEY Y TSTAT THERMOSTAT TC TEMPERATURE CONTROL TOD TOP OF OUCT TOS TOP OFSTEEL TV TURN VANES TUG TOP WAIL GRIPE TIM TOP WALL REGISTER TIP TYPICAL LINO LRAFSS NOTED 011E RWISE VD VOLUME DAMPER VF0 VARIABLEFRECWENC1TORNE O VOLTAGE PHASE & DUCT OIAMETER 1 I I 1 1 OUTSIDE AJR OPPOSED BLADE OPMPHR OUTSIDE DIMENSION RETURN AIR REGISTER (GR! LE VYITH W AMPER) REQUIRED ROUEN INCMY SUNNY AIR SMOKE CONTROL DAMPER SMOKE ONAPER SOUND UMW SKEET METAL STATIC PRESSURE STARTISTOP SOLD STATE SPED CONTROLLER STEEL SUCTION( E SUSPENDED RE: �c wirc MAP MO1t8 • • D MacDonald- Miller FACILITY SOLUTIONS ISM1.IMI 1 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206.76300 Fax: 206. 7674773 www.macmiller.com WA Llc No: MACDOFS980RU 1 EXPIRES: 07 -06-07 1 159JE NP 07 -25-07 NC MACH ERY WELD DYNO ROOM EXHAUST 17026 WEST VALLEY HWY TUCWLA . WA 98186 SCHEDULES d NOTES HVAC NCO! t ••••• 74 PATNALIRI. 07 -25-07 @®B .. B G ZO% 07 -25-07 Oft ifa art M ELECTER 07 -25-07 mac wow D - -73765)1 ISSUED FOR CONSTRUCTION TMO.O1 DATE 1