Loading...
HomeMy WebLinkAboutPermit M07-181 - SPRINT AT QUASIMOTOSPRINT AT QUASIMOTO 545 ANDOVER PK W CANCELLATION 02-15-08 M07.181 Parcel No.: 2623049144 Address: Suite No: 545 ANDOVER PK W TUKW Tenant: Name: SPRINT AT QUASIMOTO Address: 545 ANDOVER PK W , TUKWILA WA Owner: Name: SOUTHCENTER CORPORATE SQUAR Address: 150 CALIFORNIA ST , SAN FRANCISCO CA Contact Person: Name: MATT ENGLESBY Address: 568 FIRST AV S, #560 , SEATTLE WA Contractor: Name: EAGLE COMMUNICATION SERVICES Address: 1026 26 AV NW STE C , GIG HARBOR WA Contractor License No: EAGLECS972QL DESCRIPTION OF WORK: INSTALL EMERGENCY GENERATOR TO EXISTING WIRELESS FACILITY. Value of Mechanical: $8,000.00 Type of Fire Protection: NONE Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT IOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 O * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 -310 -2290 Phone: Expiration Date: 06/26/2009 M07 -181 09/13/2007 03/11/2008 Fees Collected: $246.53 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -181 Printed: 09 -13 -2007 Permit Center Authorized Signature: Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I� Permit Number: MO7 -181 Issue Date: 09/13/2007 Permit Expires On: 03/11/2008 Date: q `0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does no resume to • ' a ority to violate or can - the provisions of any other state or local laws regulating construction or the perfon work. I . thorized to sign an • - - - this mechanical permit. eS h Date: This permit shall become null and void if the work is not commenced • • 180 days from the date of issuance, or if the work is suspendec or abandoned for a period of 180 days from the last inspection. M07 -181 Printed: 09 -13 -2007 Parcel No.: 2623049144 Address: 545 ANDOVER PK W TUKW Suite No: Tenant: SPRINT AT QUASIMOTO 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -181 ISSUED 08/20/2007 09/13/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M07 -181 Printed: 09-13 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 M07 -181 Date: ordinances governing or local laws regulating Printed: 09 -13 -2007 Site Address: 5 4 A„, ,ir ✓ZC �.�, �� Suite Number: Floor: ` New Tenant: ❑ Yes `.No Property Owners Name: S wdr4. C o 1""1/4" ^ e r- (. ore cr * P �r 1S "I„ LL C . Mailing Address: C) At- �e 0 v r t c.r e-S T , 1 n i tz y W City State - • Tenant Name: > r . t, �. ,►M;.•� U CONTACT PERSON who da ire contact when your permit is re ady to be Issn CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/lwww.ci.tukwila.wo.us E -Mail Address: ill n L s . �� V✓a • Go`''Fax Number: 2 is /43 .�s S / GENERA, CONTRACTOR INFORMATION- (Contractor Informat forr Mechanical (pg <) for Plumbing ind Gas Piping (pg Company Name: 1�G1c +►+�Ll- .!'� ate•• ‘uV7Lt -S `i Mailing Address: to 2-C 26 f L Aw. 1UW G Cam•• 11 .r L-r IA/ q is3 �J State Zip Contact Person: Day Telephone: 2 - S 3 85g-- - 9 0 E -Mail Address: Fax Number: 2 5? - k 5 t i, Z Contractor Registration Number: EA c, L E C S 1721 Q L ARCHITECT OF RECORD = All plans mast be wet stamped by Architect of Company Name: Mailing Address: Contact Person: 444 / n '. 'f c E -Mail Address: .tr r �d� L1►c. t'' .: ENGIN OF' R MI p lans mast be wet stamped by Eng>I.neer of Reco Company Name: Mailing Address: 56k /' Ai,- C. 65 o iuk City Contact Person: PA- Day Telephone: E -Mail Address: Fax Number: Q:Mppliadans\Pams- Applications On Line \3 -2006 - Pamit Application.doc Revised: 9 -2006 Rh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: L 623 Day Telephone: Z� l t' G 2-q o qdbq City State Zip Expiration Date: 6 ` 2 G f e City state Day Telephone: l e 4 • Fax Number: State L 4 Zip c 7' Tap e "!v Zip Page 1 of 6 Existing Building Valuation: $ 5 60" r.). 4, Scope of Work (please provide detailed information): p .. 4 "�� € n,54'I( (',;„ en + r, .CL Valuation of Project (contractor's bid price): $ 2 /v b t, Will there be new rack storage? ❑ Yes X. No If yes, a separate permit and plan submittal will be required. ru vide All Banding Areas in Square Footage Below ?Floor 3' Floor Basement A ccessory S tructure"; Attached Garage Detached G ard Attached C ar Detached Carport Covered Deck sus Addition to . ._ Existing Structure g5 Type of :"Construction per IBC Type Occupancy per - IBC_ v PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): l✓ k Floor area of principal dwelling: 14 I - Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q.MpplialioosVrams- Applications On Line'3 -2006 - Pamit Appliaaaadoc Revised: 9-2006 bh Page 2 of 6 ewer District ...Tukwila ❑ ...Sewer Use Certificate PUBLIC WORKS PERMIT INFORMATION - 206- 433 -0179 Scope of Work (please provide detailed information): Crr• t ^ k ( r �-�� t � P. r a..�6) t2 V Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided ❑ ... ValVue ❑ ...Sewer Availability Provided Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension. Public ❑ ...Water Main Extension Public _ Q Appl om'Ycni - Applications on Linen -2006 - Pamit Appliadoadoc Revised: 9.2006 m 11 ,, WO# Call before you Dig: 1- 800 - 424 -5555 ❑ .. Abandon Septic Tank ❑.. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ,, ❑ .. Highline ❑ .. Renton WO# WO# Private Private ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Work in Flood Zone ❑ .. Storm Drainage Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billinw to: Name: Mailing Address: Water Meter RefundBillingj Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip Page 3 of 6 Unit Type: Qty > Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty' Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator— Comm/Ind MECHANICAL CONTRACTOR INFORMATION t ( � Company Name: � � a.�r►ur: G•.tb• - • > crlr :s.L S n � Mailing Address: I 02 ( 2C -' A-Yt; N W G C;,:.,. (� t 4k3 , City - State Zip Contact Person: Day Telephone: 2 53 ' k i (s - 7 Ci / l E -Mail Address: Fax Number: Contractor Registration Number: 14 LE G S¶ 7 L Q' L Expiration Date: 6/2-67 6 ei Valuation of Mechanical work (contractor's bid price): $ g G G 6 Scope of Work (please provide detailed information): T +a . " ;; 'fc /( ern er , l Crier - cVor •k—o C � nr e (e,SS f't Um Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ...% Fuel Type: Electric ❑ Gas .... ❑ Other J: �t? Indicate type of mechanical work being installed and the quantity below: Q.1Applications\Fams- Applications On Line \3.2006 - Permit Appliationdoc Revised: 9-2006 m Page 4 of 6 Fixture Type: '" =Qty Fixture Type: Qty ' Future Type. ". ? :Qty . ' Future Type: - Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Company Name: Mailing Address: r�. 1J Contact Person: E - Mail Address: tU L Contractor Registration Number: r�- PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ PA Scope of Work (please provide detailed information): N Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:Mpplica6o&Pants- Applications On rine\3 -2006 - Permit Applicationdoc Revised: 9-2006 bit City State Zip Day Telephone: Fax Number: Expiration Date: Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Page 5 of 6 PERNIIT APPLICATION NOTES - 'Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). plumbin Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A ENT: e/4/2 Signature: ;G Date: 2,3 �' 7 Day Telephone: 2 G 3/.a 27 ' k ; les 16'1 Print Name: /IA r' Fan Mailing Address: 54 k /5=- A Date Application Accepted: Q:Mpplications\Foams- Applications On rineO -2006 - Permit Applintion.doc Revised: 9 -2006 hh S. 1...* 650 City State Zip Date Application Expires: 2 -20 - 0 Staff Initials: Page 6 of 6 Receipt No.: R07 -01745 Payee: PACIFIC TELECOM SERVICES LLC ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049144 Permit Number: M07 -181 Address: 545 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 08/20/2007 Applicant: SPRINT AT QUASIMOTO Issue Date: Initials: ELK Payment Date: 08/20/2007 01:40 PM User ID: ADMIN Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 13162 246.53 Account Code Current Pmts 000/322.100 203.22 000/345.830 43.31 Total: $246.53 Payment Amount: $246.53 1774 08/20 9710 TOTAL 246. c3 doc: Receiot -06 Printed: 08 -20 -2007 rrAq 44 "- 40kW Diesel On- Site POWER Power Industrial Generator Model MQP4OSS Emissions EPA Certified Standby Rating 60 Hertz 40 kW (50 kVA) Prime Rating 36 kW (45 kVA) FILE COPY Standard Features Heavy Duty Engine I Heavy duty, 4- cycle, diesel engine; turbocharged, direct injection, water cooled, overhead valves. • Manual speed control governor. • Meets EPA emissions standards for mobile off - highway. Alternator • Brushless, 4 -pole, synchronous, 12 lead design. • Class H insulation system conforms to NEMA MG1 -22, BS5000, CSA- C22 -2, IEC -34 -1 standards for temperature rise. • Sustained short - circuit capability allowing downstream coordination breakers to trip without collapsing the generator field. • Drip - proof, self- venting, amortisseur windings. • Epoxy impregnated windings with tropical insulation for increased environmental protection and long life. • Exceptional waveshape and voltage balance; 2/3 pitch winding to minimize harmonic distortion. Electronic Voltage Regulator • Encapsulated electronic voltage regulator precisely regulates the current into the exciter field. • Voltage regulation of ±1.0% no load to full load. Full Load Acceptance • Accepts 100% of standby nameplate rating in one step, in compliance with NFPA, para 5- 13.2.6. 1nt 1 1 REVIEWED FOR CODE COt.IPLIANCE SEP 12 2007 RECEIVED CRY OF TUKWILA AUG 20 2001 -• r Cooling System • Closed circuit, pressurized system with ambient temperature rating of 40 °C (104 °F). Generator Control Panel • ICS -50TM' microprocessor- based, digital control panel; vibration isolated and NFPA 110 compliant. • Liquid crystal display screen with alphanumeric readout for display and programming. • Self- diagnostic feature continuously verifies processing, memory circuits and input/output. Skid and Housing • Outdoor weather-protective, sound - attenuated housings with single - side access doors. • Generator available as skid -mount or sub -base tank mount design. • Integral vibration isolators. • Steel battery rack and battery cables. Warranty • Engine - generator sets are covered by an express written 2 -year! 2000 hour (whichever occurs first) limited warranty. • Optional extended warranties available. Agency Approval • UL 2200 certification. MO1 Ib( Alternator Specifications p Manufacturer/Model Standard 3 -Phase Generator Marathon MagnaPlus 284PSL1742 Optional Full Output 1 -Phase Generator Marathon MagnaPlus 284PSL1750 Type 4 -Pole, Rotating Field 4 -Pole, Rotating Field Exciter Type Brushless, Shunt Excitation Design Brushless, Shunt Excitation Design Number of Leads 12 Lead, Broad Range, Reconnectable 4 Lead Voltage Regulator SE350, Solid State, Volts -per -Hertz SE350, Solid State, Volts- per -Hertz Insulation NEMA MG1 -1.66 NEMA MG1 -1.66 Material Class H Class H Temperature Rise 125 °C, Standby Rating 125 °C, Standby Rating Bearing, Type Single, Sealed Single, Sealed Coupling Flexible Disk Type Flexible Disk Type Cooling Air Volume 250 dm (7.1 ma /min.) 250 cfm (7.1 m3 /min.) Amortisseur Windings Full Full Voltage Regulation (no load to full load) ±1% ±1% Single Step Load Acceptance per NFPA 110 100% of Rating 100% of Rating Amperage Voltage Phase Wire Amperage 120/208 Volt 3 4 138 120/240 Volt 3 4 120 277/480 Volt 3 4 60 120/240 Volt 1 3 133 120/240 Volt Full Output 1 3 167 Engine Specifications Manufacturer/Model Isuzu 4JGITPV -01 Type 4 - cycle direct injection, turbocharged, water cooled Cylinder Arrangement 4 In -Line Displacement 189 in (3.1 liter) Bore 3.74 in. (95 mm) Stroke 4.21 in. (107 mm) Compression Ratio 18.6:1 Cylinder Block Cast iron Cylinder Head Cast iron, overhead valves Crankshaft High carbon steel, forged and tuftrided Brake Mean Effective Pressure (BMEP) 153,65 psi (1.06 Mpa) Rated RPM 1800 RPM Max. Power it Rated RPM (with fan) Standby: 66.0 bhp (49 kW) Prime: 58 bhp (43 kW) Governor Type Mechanical Frequency Regulation: no load to full load 8% under varying loads from no load to 100% rated load. Frequency Regulation: Steady State ±0.5% of mean value for constant loads from no load to full load. Air Cleaner Type Dry Lubrication System Type Gear Driven System Capacity-Less Filter 2.0 gallons (7.6 liters) System Capacity-With Filter 2.5 gallons (9.6 liters) Oil Filter Full flow disposable spin -on Oil Cooler Integral Oil Temperature Normal Range 185 - 230°F (85 110°C) Maximum Range 230°F (110°C) Electrical System Battery Charging Alternator - Make Hitachi Ground Type Negative Volts (DC) 12VDC Ampere Rating 50A Starter Motor Make/Model Mitsubishi Starter Motor Rated Voltage 12VDC Starter Motor Battery Capacity 650 Ah Pre - Heater Type Glow Plugs Inrush Current 860 A Cranking Current 600 A POWER 4 0kW Diesel On -Site Power Industrial Generator Rating Guidelines STANDBY POWER: Rating corresponds to ISO Standard Fuel Stop Power. It is applicable for supplying standby electrical power at variable load in areas with well established electrical networks in the event of normal utility power failure. No overload capability is available for this rating. PRIME POWER: Rating corresponds to ISO Standard Power for continuous operation. It is applicable for supplying electrical power at variable load for an unlimited number of hours instead of commercially purchased power. A 10% overload capability is available for this rating. SINGLE PHASE OUTPUT: Broad range alternators can supply single phase output up to 2/3 set rated 3 -phase kW at 1.0 P.F. Refer to Amperage mart. Cooling System Exhaust Manifold Type Dry Radiator Design Standard horizontal discharge Ambient Temperature Rating 180°F (82°C) Coolant Capacity (Engine Only) 1.3 gallons (5.0 liters) Water Pump Design/Type Belt driven, Centrifugal Vane Coolant Flow 19.5 gaVmin (73.8 Umin) Radiator Cooling Air 85.0 cfm (2.41 m /min) Heat Rejection At Rated Load: From Engine Standby: 364.2 Btu/min (6.4 kW) Prime: 313.0 Btu/min (5.5 kW) To Coolant Standby: 1992.2 Btu/min (35 kW) Prime: 1764.5 Btu/min (31 kW) Fan Diameter 15.7 in. (400 mm) Fan Horsepower 0.8 hp (0.6 kW) High Water Temperature Indication Pre - Alarm: 210.2 °F (99 °C) Shutdown: 221.0 °F (105 °C) Pressure Cap Setting 7 psi (48 kPa) Fuel System Fuel Injection Pump Make Bosch / Zexel Recommended Fuel ASTM -D975 / No.2 -D Feed Pump Pressure 24.9 psi (172 kPa) Feed Pump Maximum Suction Head 3.3 feet (1.0 meter) Fuel Filter Replaceable, spin -on, paper element type filter Total Fuel Flow 39.6 gal/hr (150 L/hr) Fuel Consumption Diesel Fuel At % of Load Standby gal/hr (Uhr) Prime gaVhr (Uhr) 100% 3.4 (12.9) 2.9 (11.0) 75% 2.4 (9.1) 2.2 (8.3) 50% 1.7 (6.4) 1.6 (6.0) 25% 1.1 (4.5) 1.1 (4.5) 40kW Diesel On -Site POWER Power. Industrial Generator Exhaust System Exhaust Flow at Rated kW Exhaust Temperature at Rated kW Maximum Allowable Backpressure Heat Rejection To Exhaust Standby: 331.9 cfm (9.4 m /min) Standby: 856°F (458°C) 40.95 in/wc (10.2kPa) Standby: 56kW 3187.52 Btu/min Derating Factors The engine may be operated up to 500 ft. and up to 25 °C without derating. For operation at higher altitudes and ambient temperatures, the power should be derated according to the following factors: Altitude 3% / 1000 ft. Ambient Temperature 0.36% 1°C GENERATOR CONTROLLER • ICS -50n`t microprocessor -based digital generator controller. • 12 or 24 Volt DC compatible. • Meets all NFPA 110 requirements for emergency power systems Level I installations. • Baddit LCD display screen with alphanumeric readout. • Front panel keypad provides password protected programming. • Self diagnostic features continuously verify processing, input/ output and memory circuits. • Metering accurate to +1% within temperature range of 0°C to +50°C. • EMI /RFI noise immunity and surge performance per IEEE C62.41. • Certified to UL508 and CSA 22.2 #14 Industrial Control Equipment Standards. AC Metering Display: • Voltage /Amperage/ Frequency • Generator Phase Voltage / Current • Generator Frequency Engine Information Display: ■ Engine Temperature / Oil Pressure (psi) ■ Battery Voltage (DC) / Tachometer • Hourmeter Timer Countdown Display: • Engine Start Delay a Oil Bypass • Overcrank • Cycle Crank • Rest Period • Starter Re- engage Delay • Bypass Delay Minor Fault Warning Display: • Switch Not In Auto • Low Fuel Level • Low Oil Pressure Alarm • Low Engine Temperature • High Engine Temperature Alarm • Low Battery Voltage • High Battery Voltage • Weak Battery Condition • Battery Charger Input Fail • Undervoltage ■ Underfrequency • Overfrequency • Overcurrent Major Fault Shutdown Display: • Overvoltage Standard Controller Features • Emergency Stop ■ Loss Of Speed • Overcrank • Overspeed ■ Low Oil Pressure ■ High Engine Temperature ■ Low Coolant Level • Spare Programmable Digital Faults Switches And Operating Controls: • Run / Off / Auto / Load Test Buttons • Decrement / Increment / Previous (Exit) /Next (Enter) Program Buttons • Emergency Stop Button a Audible Alarm Horn - 80 dB(A) at 2 feet ■ Alarm Horn Silence Button • Lamp Test Button • Fault Reset Function • RJ45 Remote Communications, External Expansion Module Ports Control LED Indicators: ■ Switch Position (Run, Off, Auto, Load Test) • Common Alarm (Minor Fault) • Common Shutdown (Major Fault) ■ Generator Ready (When in Auto) • Speed Signal • Emergency Stop Diagnostic LED Indicators: ■ Run Output Energized a Crank Output Energized • Remote Start Signal Initiated or Common Fail Output Energized • Watchdog - CPU Running • Programmable Output Contacts Weights and Housing Options Dimensions A B C Skid -mount 12hr fuel tank' 24hr fuel tank' Open Genet 84 in. (2,133 mm) 34 in. (863 mm) 43 in (1,092 mm) 48 in. (1,245 mm) 58 in. (1,473 mm) Weight 1,466 lbs (665 kg) 1,925 lbs (873 kg) 2,030 lbs (921 kg) Standard 84 in. (2,133 mm) 34 in. (863 mm) 66 in. (1,676 mm) 72 in. (1,829 mm) 81 in. (2,057 mm) Weight t,893 lbs (859 kg) 2,352 lbs (1,067 kg) 2,457 lbs (1,114 kg) Sound Attenuated 84 in. (2,133 mm) 34 in. (863 mm) 66 in. (1,676 mm) 72 in. (1,829 mm) 81 in. (2,057 mm) W ght 1,946 lbs (883 kg) 2,405 In (1,090 kg) Z510 lbs (1,138 kg) 4 40kW Diesel On -Site POWER Power Industrial Generator Generator Set Options Alternator ❑ Full output 1 Phase Alternator ❑ Generator Strip Heater o Permanent Magnet Generator (PMG) Control Panel o Remote Monitoring and Generator Network Communications Link o Voltage Adjusting Rheostat Cooling System o Coolant Heater a Low Coolant Shutdown Safety o Radiator Duct Flange Engine o Electronic Governor o Engine Crankcase Ventilation Filter Enclosed Unit o Outdoor Weather- protective Housing o Outdoor Sound - Attenuated Housing o Critical Grade Exhaust Silencer o Exhaust Mounting Package o Rain Cap Open Unit ❑ Critical Exhaust Silencer o Exhaust Mounting Package Electrical System o Battery o Environmental Plastic Battery Box o Battery Charger, Equalize /Float Type 3.5 Amperes ❑ Battery Charger w /Alarms, Equalize/Float Type, 10 Amperes Fuel System ❑ Sub -base Fuel Tank (12 -hr / 39 gal), Double Wall, UL142 ❑ Sub -base Fuel Tank (24 -hr / 77 gal), Double Wall, UL142 Automatic Transfer Switch ❑ Amperage ❑ No. Poles ❑ Type Enclosure ❑ Options Optional NOTE: Weights are based on dry genets with standard equipment. The total weight may vary according to fluid additions and/or optional equipment ordered with the unit. Backfeed to a utility system can cause electrocution and/or property damage. Do not connect to any building's electrical system except through an approved device. Specifications are subject to change without notice. Your MO Power dealer is: C COPYRIGHT 2007, MQ POWER Rev. 0 (05 -07) MOP4OSS POWER Miscellaneous ❑ Main Line Circuit Breaker ❑ 120/208 Volt, 3 Phase, 3 Pole 0 120/240 Volt, 3 Phase, Delta, 3 Pole ❑ 139/240 Volt, 3 Phase, 3 Pole ❑ 277/480 Volt, 3 Phase, 3 Pole o 120/240 Volt, 1 Phase, 2 Pole ❑ Main Line Circuit Breaker Options ❑Auxiliary Contacts a DC Shunt Trip a Remote Annunciator Panel ❑ Remote Emergency Stop Kit o Vibration Isolators, Spring Type 1r A 0 a o I1 11 0 1 r MO POWER POST OFFICE BOX 6254 CARSON, CA 90749 310 - 537 -3700 • 800- 883 -2551 FAX: 310 -632 -2656 E -MAIL: mqpower@multiquip.com WEBSITE: www.mqpower.com 02 -12 -2008 MATT ENGLESBY 568 FIRST AV S, #560 SEATTLE WA 98104 RE: Permit No. M07 -181 545 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/11/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Permit Technician xc: Permit File No. M07 -181 city of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: Bui 1'I S g Division PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -181 DATE: 08 -20 -07 PROJECT NAME: SPRINT AT QUASIMOTO SITE ADDRESS: 545 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued 1 Fire revention Public Works ❑ Structural ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: Incomplete n TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: DUE DATE: 08-21-07 DATE: DATE: Planning Division Not Applicable E Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required n DUE DATE: 09-18-07 Approved ❑ Approved with Conditions Iv l Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License EAGLECS972QL Licensee Name EAGLE COMMUNICATION SRVCS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602037526 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 1026 26TH AVE NW, SUITE C Address 2 12/01/2005 City GIG HARBOR County PIERCE State WA Zip 98335 Phone 2538589611 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/13/2003 Expiration Date 6/26/2009 Suspend Date Separation Date Parent Company Previous License EAGLECNOO6L6 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PERRYCOOK, JAY PRESIDENT 12/01/2005 PERRYCOOK, TAHIRIH SECRETARY 12/01/2005 PAGE, KEVIN S PRESIDENT 11/13/2003 12/01/2005 PAGE, LAURA S SECRETARY 11/13/2003 12/01/2005 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= EAGLECS972QL 09/13/2007 d`d m m m da i REVISIONS 07/ I0 /07 08/08/07 LO /£I /801 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION Q .. By Date: Plan review approval is subject to errors and omissions Approval c'r ccr 1.!ctlon documents does not authorize the vloic'.t..'.• l �I l_.a {......:� ...d code or ordinance. Receipt Of apprcvc :_:a C_ _-J ccnd ter is admot dged: 6 City of 'Tt,kwila BUILDING DIVISION PROJECT INFORMATION PROJECT DESCRIPTION: SPRINT — NEXTEL PROPOSES TO AMEND AN EXISTING UNSTAFFED TELECOMMUNICATIONS FACILITY WITH THE ADDITION OF A 40KW DIESEL GENERATOR AND FUEL TANK MOUNTED ON A NEW CONCRETE PAD. SITE ADDRESS: PROPERTY OWNER: APPLICANT: PROJECT CONTACT: LATITUDE: LONGITUDE: LAT /LONG TYPE: ELEVATION: PARCEL NUMBER: CURRENT USE: PROPOSED USE: POWER: TELCO: JURISDICTION: ZONING: APPLICABLE CODE: CONSTRUCTION TYPE: OCCUPANCY TYPE: PROJECT AREA: VALUATION: 545 ANDOVER PARK W TUKWILA, WA 98188 SOUTHCENTER CORPORATE SQUARE, LLC. 635 ANDOVER PARK WEST, STE 107 TUKWILA, WA 98188 SPRINT /NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 MATT ENGLESBY PHONE: (206) 310 -2290 EMAIL: MENGLESBYOPTSWA.COM 47 27' 05.9" N 122' 15' 25.1" W NAD 83 26' AMSL 2623049144 TELECOMMUNICATIONS FACILITY TELECOMMUNICATIONS FACILITY PSE PHONE: (888) 227 -5773 QWEST PHONE: (800) 603 -6000 CITY OF TUKWILA TUC 2006 IBC II —B UNOCCUPIED APPROX. 130 S.F. $10,000 REVISIONS No changes shall b made ade to scope of work without prior approval Tukwila Building Division. NOTE: and may include ' al plan plan w fees. submittal an y print. Together with NEXTEL QUASIMOTO WA0234 " j SaAhcente2 Ma r---- 5oulhcant SGaiider13!W=__. StrandeLLIN T ?land Dr" VICINTY MAP DRIVING DIRECTION DEPART: 10545 WILLOWS RD NE, REDMOND, WA 98052 ON WILLOWS RD NE (SOUTH) TURN RIGHT (WEST) ONTO SR -908 [REDMOND WAY] TURN OFF ONTO RAMP 0.6 MI 1 -405 / RENTON MERGE ONTO 1 -405 (SOUTH) AT 1 -405 EXIT 1, TURN OFF ONTO RAMP WA -181 S / TUKWILA / W. VALLEY HWY. TURN RIGHT (EAST) ONTO INTERURBAN AVE S CONTINUE (SOUTH —EAST) ON SR -181 [W VALLEY HWY] TURN RIGHT (WEST) ONTO STRANDER BLVD TURN LEFT (SOUTH) ONTO ANDOVER PARK W ARRIVE: 545 ANDOVER PARK W, SEATTLE, WA 98188 EPARATE PERMIT REQUIRED FOR: 011,Mdchanical ❑ Plumbing 0 Gas Piping City of Tukwila BUILDING DIV E INDEX T -1 TITLE SHEET AND GENERAL INFORMATION G -1 GENERAL NOTES A -1 SITE PLAN A -2 ENLARGED SITE PLAN A -3 GENERATOR AND EQUIPMENT DETAILS A -4 GENERATOR PAD DETAILS A -5 WOOD FENCE DETAILS E -1 GROUNDING PLAN AND ELECTRICAL NOTES E -2 MQ POWER DIESEL GENERATOR AND ALARM WIRING E -3 ATS CABLE SCHEDULE AND ATS ALARM WIRING E -4 ELECTRICAL_DET RE \f o b p F ��� CODE COIF _ S EP 12 2001 Of Tuk lla CRY — ��T ;1� A CT TEAM DESIGN TEAM THOMAS R. HOLLAND, AIA PACIFIC TELECOM SERVICES, LLC 568 FIRST AVE S, SUITE 650 SEATTLE. WA 98104 -2804 CONTACT: STEVE ISHIHARA PHONE: (206) 342 -9000 EXT. 412 FAX: (206) 903 -8513 EMAIL: SISHIHARAOPTSWA.COM ZONING CONTACT PACIFIC TELECOM SERVICES, LLC 568 FIRST AVE S, SUITE 650 SEATTLE, WA 98104 -2804 CONTACT: MATT ENGLESBY PHONE: (206) 310 -2290 E —MAIL: MENGLESBYOPTSWA.COM CURRENT ISSUE CONSTRUCTION DRAWINGS' APPROVALS: SPRINT /NEXTEL• LANDLORD CONST• S /A• RF• ZONING. A &E• PRIME CONTACT SPRINT /NEXTEL 10545 WILLOWS RD NE SUITE 100 REDMOND, WA 98052 CONTACT: BRYAN ADAMS OFFICE: (425) 278 -2109 PROJECT MANAGER PACIFIC TELECOM SERVICES, LLC 568 FIRST AVE S, SUITE 650 SEATTLE, WA 98104 -2804 CONTACT: LORI CHASE PHONE: (206) 342 -6386 EMAIL: LCHASEOPTSWA.COM DATE RECEIVED CITY OF TUKWILA AUG 2 0 20011 PERmti CENTEc: Together with NE7CTE 103MS WILLOWS 3D M2 51111[ IMO SWOONS, WA 99032 MnOML' 423273.2400 1111111=1111 PACIFIC TELECOM SERVICES, LLC 3M Mn1 Avenue S.. 3ANM Ala S.W. WA. M1D4 Mown (ms) 142 -3000 2m (203) 903 -I51: 407 f. EREC TECT THOMA R. HOLLAND STATE • WASHINGTON 0 d d" N O JOB I WA0234 REVISION TITLE SHEET AND GENERAL INFORMATION DRAWING # T -1 0 TUKWILA, WA 98 88 545 ANDOVER PARK W db. Hl c. m J IE3l j ai REVISIONS 07/10/07 08/08/07 ILO /£I /80 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION I .. STRUCTURAL STEEL NOTES 1. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND IN ACCORDANCE WITH ASTM A36 UNLESS OTHERWISE NOTED. 2. ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC AND AWS D1.1. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION ". PAINTED SURFACES SHALL BE TOUCHED UP. 3. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYPE (3/4"0) CONNECTIONS AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 4. NON- STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A 307 BOLTS UNLESS NOTED OTHERWISE. 5. INSTALLATION OF CONCRETE EXPANSION /WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. SPECIAL INSPECTIONS, REQUIRED BY GOVERNING CODES, SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE LOADS. 6. EXISTING PLATFORM INSTALLATIONS SHALL INCLUDE THE INSTALLATION OF AN ANGLE UNDER THE STRUCTURAL MEMBER OF THE PLATFORM TO SECURE THE GENSET TO THE PLATFORM IN LIEU OF THE GATING. 7. SURFACE MOUNTING OF CONDUITS SHALL BE AVOIDED AT ALL POSSIBLE LOCATIONS WHERE PEDESTRIAN TRAFFIC CAN OCCUR. WHERE THIS IS UNAVOIDABLE, GRIP STRUT BRIDGING SHALL BE USED FOR INSTALLATION TO PROTECT THE CONDUITS AND POTENTIAL FOR PERSONNEL TRIPPING HAZARDS. ELECTRICAL NOTES: 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S SPECIFICATIONS AND RECOMMENDATIONS. 3. ALL GROUND CONNECTIONS SHALL BE CADWELD. BELOW GRADE ALL WIRES SHALL BE COPPER THHN/THWN. ABOVE GRADE ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE. 4. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 5. RIGID CONDUIT SHALL BE USED WHERE DAMAGE CAN OCCUR FROM VEHICULAR TRAFFIC OR EQUIPMENT DELIVERY EXERCISES. 6. ATS AND GENSET LABELS ARE TO BE PROVIDED AND INSTALLED WITH SERIAL AND CASCADE NUMBERS FOR THE ATS AND GENSETS. LABELS SHALL BE ATTACHED VIA ALUMINUM OR SS SCREWS - CONSTRUCTION MANAGER TO PROVIDE TO SUBS FOR INSTALLATION AT THE SITE. 7. NEW INSTALLATION SHALL BE PVC CONDUIT, USE SCH 80 ABOVE GROUND AND SCH 40 BELOW GROUND. ALSO REFER TO CONSTRUCTION MANAGER DIRECTION FOR ANY CONDUIT EXPOSED TO TRAFFIC (VEHICLE OR FOOT). 8. CONTRACTOR TO PROVIDE A NEW 66 BLOCK IF REQUIRED, WITH FURTHER ROUTING TO THE RBS EQUIPMENT CABINET AND LEFT WITH A 2' COIL OF WIRE. ALARM CABLING IN THE TELCO CABINET SHALL BE INSTALLED IN A NEAT FASHION WITH A 6" SERVICE COIL. CONTRACTOR SHALL NOT MAKE PUNCH DOWNS ON THE TELCO BOARD 66 BLOCK GENERAL NOTES: 1. THE SPRINT /NEXTEL METHOD OF PROCEDURE (MOP) MOPS 2061108 INSTALLATION OF PAD MOUNTED GENERATOR SETS IS THE BASIS FOR ALL TECHNICAL INSTALLATION SPECIFICATIONS; IN THE EVENT THERE IS A CONFLICT BETWEEN THESE CONSTRUCTION DOCUMENTS OR THE INSTALLATION CHECKLIST AND THE GENSET MOP, THE CONTRACTOR SHALL FOLLOW THE DIRECTIVE DESCRIBED WITHIN THE MOP AND CONTACT THE CONSTRUCTION MANAGER TO APPRISE. EXCEPT NO PORTABLE GENERATOR S/0 CORD SHALL BE REMOVED 2. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 3. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE PORTABLE WATER OR SEWER SERVICE. 4. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). 5. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS WERE PREPARED FROM SITE SPECIFIC DETAILS AND STANDARDIZED DETAILS DEVELOPED BY PACIFIC TELECOM SERVICES, LLC. STANDARDIZED DETAILS ARE TO BE CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. MODIFICATIONS DUE TO FIELD CONDITIONS MUST BE SUBMITTED TO, AND APPROVED BY, SPRINT /NEXTEL PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. 7. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. ALL INSTALLATIONS SHALL BE 1007 CLEAN OF ALL DEPRIS AND METAL FILINGS SHALL BE REMOVED FROM ENCLOSURES, SITE AREA, FIXTURES, PLATFORMS, ETC. 8. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION /CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER VERBALLY AND IN WRITING. 9. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS /CONTRACT DOCUMENTS. 10. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. TH CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENC AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. TO GENERAL NOTES (CONT.): 11. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 12. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 15. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2 -A OR 2-Al OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 16. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 17. THE ARCHITECTS /ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT /ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 18. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 19. CONTRACTOR SHALL CALL WASHINGTON UTILITY COORDINATING COUNCIL SERVICE FOR UNDERGROUND UTILITY MARKOUT PRIOR TO CONSTRUCTION 1- 800 - 424 -55 S , COM COQ I ANCE SEP 2, 2001 CAV Of 110/4y. 6 0 . 1114G DINTS . . RECEIVED CITY OF TUKWILA AUG 20 20011 PERMIT CENTER Together with NE9CTE 10545 1111DW9 1D MC SUE 100 1000050. WA 51051 PHOM4 415171.7400 PACIFIC TELECOM SERVICES, LLC 5M 2050 Amy. S. SARA 550 1,"MY, WA. N104 10,2,.0 (M/) 341 -0000 Fm (101) 501 -5511 407 Cr) N C JOB # WA0234 G GEN REVISION -1 RAL NOTES TEREE ITECT THOMAS R. HOLLAND STATE OF WASHINGTON ac co O Z DRAWING # G -1 0 db — — I— -I -- C Comm J J va REVISIONS 07/10/07 08/08/07 LO /£I/80 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION Q m o 262304 144 LOT 4 OF CITY OF TUKWILA SHORT PLAT NO L97 -0049 RECORDING NO 9711069009 SAID SHORT PLAT DEFINED - PORTION OF E 1/2 OF NW 1/4 OF SE 1/4, BEGIN NE CORNER OF SAID E 1/2 BEING N 88 -05 -42 W 1339.34 FT FROM NE CORNER OF SE 1/4 TH S 01 -47 -29 W 1322.34 FT TO SOUTHEAST CORNER TH N 87 -55 -02 W 659.35 FT TO W LINE OF E 659.34 FT OF SAID E 1/2 TH N 01 -47 -29 E 1320.30 FT TO N LINE OF SAID E 1/2 TH S 88 -05 -42 E 659.34 FT TO POB LESS PORTION FOR 59TH AVE SOUTH LESS PORTIONS FOR STREETS AS CONVEYED BY DEED, RECORDING NO 7907120770 LESS PORTION CONVEYED TO CITY OF TUKWILA FOR ROAD BY DEED, RECORDING NO 9408290327 LEGAL DESCRIPTION /EXISTING WETLAND AREA/ EXISTING BUILDING (TYP) EXISTING 17-5" X 32' -2" FENCED COMPOUND EXISTING 5O' -0" MONOPOLE (ANTENNA ARRAYS NOT SHOWN FOR CLARITY) 4 PROPERTY LINE -- _ PROPERTY LINE CODE COMPU!\ C APT-71013a Caa PROPERTY Li p 1 2 2Q9 CORPORA E Buis RE EED CITY Q TUKWILA 1 4 0 0 2007 PER CENTE1, SCALE (24' X 36') 1'- 40' -0' SCALE (11' x 17') SITE PLAN Together with NEXTE 1050 WILLOWS RD NC SURE 100 1(00050. WA 98032 PRONE: 425.2711400 PACIFIC TELECOM SERVICES, LLC S00 0314 Avenue 1. sun. 030 Sa01y WA. 11104 Phone (201) 312 -0000 ran (201) 103-1513 4072 THOMAS R. HOLLAND STATE OF WASHINGTON O O m • N • 0 Q V JOB # WA0234 REVISION SITE PLAN - 1 ERED ITECT DRAWING # A -1 0 ANDOVER PARK W S45 ANDOVER PARK W TUKVV1LA, WA 98188 de F- F- I Tl M m I°= J -1 i 1 REVISIONS LO/8O/80 LO /Ol /LO ILO /£t /80 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION I Q CO O EXISTING WOOD FENCE TO BE REMOVED PROPOSED NEXTEL 8' -0' WOOD FENCE (TO MATCH EXISTING WOOD FENCE) N N 17-5" 8' -0" ❑ ❑ EXISTING BUILDING O O O ❑ 0 PROPOSED NEXTEL (2) 4' - WOOD GATES PROPOSED NEXTEL 40kw DIESEL GENERATOR AND FUEL TANK ON 5' -0' X 8' -0' CONCRETE PAD PROPOSED NEXTEL (4) UNDERGROUND GENERATOR CONDUITS (APPROX. 23' RUN) PROPOSED NEXTEL ATS INSIDE EQUIPMENT SHELTER (FIELD VERIFY EXACT LOCATION) EXISTING NEXTEL 11' -6" X 20' -0" EQUIPMENT SHELTER EXISTING 8' -0" WOOD FENCE EXISTING NEXTEL WAVEGUIDE EXISTING SO' -0" MONOPOLE (ANTENNA ARRAYS NOT SHOWN FOR CLARITY) EXISTING COMPOUND TRANSFORMER EXISTING DUMPSTER CO. CODE SE P 12 2101 C if ' Of Tv:sla Bu RDING Ilk SECENED CITY OF TUKWILA AUG 20 2001\ PEt MtT CENTCP am In MI NE SCALE: (24' X 367 1/4'+•1' -0' SCALE: (11' X 17') 1/6'..1' -O' 4 3 2 1 0 4' ENLAR.GED SITE PLAN Together with NEXTE 10545 WILLOWS 6c x[ SUM loo 1E00000. WA 118052 1.1106. 424 2160400 PACIFIC TELECOM SERVICES, U-C 558 7301 •..e4. 3. 9W(0 550 9•49(0, WA. 116104 F.ps (206) u2 -9000 kw (206) 003 -6513 407 ' REGIST ' ED ' , . ECT THOMAS R. HOLLAND STATE OF WASHINGTON d" CO N O A EN LA JOB # WA0234 REVISION -2 GED SITE PLAN DRAWING # A -2 0 TUKWILA, WA 98 I 88 545 ANDOVER PARK W PROPERTY LINE db. I II 30 -150 (1) #14 TO 4/0 AWG AL —CU WIRE 200 -230 (1) #14 TO 4/0 AWG COPPER WIRE mmm Ala j ai REVISIONS 07/10/07 08/08/07 L0 /EI /80 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION < m o SWITCH RATING (AMPS) RANGE OF WIRE 30 -150 (1) #14 TO 4/0 AWG AL —CU WIRE 200 -230 (1) #14 TO 4/0 AWG COPPER WIRE SWITCH RATING (AMPS) RANGE OF WIRE 30 -150 (1) #14 TO 4/0 AWG AL —CU WIRE 200 -230 (1) #14 TO 4/0 AWG COPPER WIRE ASCO 7000 SERIES AUTOMATIC TRANSFER SWITCH (30 -230 AMPS) GENERAL NOTES 1. TYPE 3R/4/4X/12 WALL MOUNTED ENCLOSURE. 2. FINISH TYPE 3R/4/12: ANSI 61 GREY. TYPE 4X CONSTRUCTED OF 12 GAUGE 304 LOAD STAINLESS STEEL. 3. PLATED DOOR CLAMPS AND PADLOCK HASP ON LEFT SIDE. 4. SINGLE DOOR HINGED ON RIGHT 5. TERMINALS — SCREW TYPE LUGS FOR EXTERNAL POWER CONNECTIONS. 6. THREE POLE SWITCH WITH SOLID NEUTRAL SHOWN FOR REFERENCE. 7. THREE POLE SWITCH WITH SOLID NEUTRAL SHOWN FOR REFERENCE. 8. NEUTRAL CONFIGURATIONS: AN OPTIONAL FULL RATED NEUTRAL CONFIGURATION FOR EACH SOURCE AND THE LOAD MAY BE PROVIDED. WHEN EQUIPPED IT IS IN ONE OF THE FOLLOWING FORMATS AS SPECIFIED BY THE CATALOG NUMBER NO. NEUTRAL TYPE: (A) SOLID (COPPER BUS) NEUTRAL (B) SWITCHED NEUTRAL POLE (C) OVERLAPPING NEUTRAL POLE CAM —LOK CONNECTOR ENCLOSURE (4) .43 DIA. MOUNTING HOLES PROPOSED NEXTEL 5' -0" X 8' -0" CONCRETE PAD —( 9 T 1 EXISTING GRADE FRONT EMERGENCY M1� GENERATOR VENT PROPOSED NEXTEL 40kw SINGLE SIDE SERVICE GENERATOR PROPOSED NEXTEL 77 GALLON DIESEL FUEL TANK FRONT VIEW WITHOUT DOOR BOTTOM VIEW SOLID 1 NEUTRAL NORMAL 2" 7-5" 8' -0" TOP alsg ASIt 2" FRONT VIEW WITH DOOR KNOCKOUTS LEAVE INTACT FOR TYPE 12 REMOVE FOR TYPE 12 NOT AVAILABLE ON TYPE 4,4X GRADE LEVEL EXTERIOR WALL ATS CABINET (OUTDOOR) SCALE: (24"X36'): NOT TO SCALE SCALE: (11 "X17"): NOT TO SCALE 1' -2 RIGHT SIDE GROUND LUG MOUNTING STUDS DAQE GENERATOR 4 SCALE (24")(36"):1/2 " =1' -0" SCALE: (11"X17"): 1/4" =1' -0" LOAD EMERGENCY 0 TYP TOP AND BOTTOM TOP VIEW FRONT VIEW WITHOUT DOOR SOLID NEUTRAL NORMAL ODE coviputal 77 �' U o a SE? 2 1 01 1 City o TOO BUILDING D 1 2 .75 —.50 COMBINATION PILOT KNOCK —OUTS. TOP AND BOTTOM (4) .37 —DIA. EXTERNAL DIMPLED MOUNTING HOLES 9 " 000 00 GENERAL NOTES 1. TYPE 1 WALL MOUNTED ENCLOSURE. 2. STANDARD FINISH — LIGHT GREY, ANSI 61. 3. KEY LOCKABLE HANDLE. 4. REMOVEABLE SINGLE DOOR. 5. TERMINALS — SCREW TYPE LUGS FOR EXTERNAL POWER CONNECTIONS. 6. a CENTER OF GRAVITY. 7. THREE POLE SWITCH WITH SOLID NEUTRAL SHOWN FOR REFERENCE. , I itti 1 —6" X FRONT VIEW WITH DOOR INTERIOR WALL 1 -1" ATS CABINET (INDOOR) SCALE (24"X36"): NOT TO SCALE SCALE: (11"X17"): NOT TO SCALE FOUNDATION SECTION SCALE: (24"X36"): 1 -1/2" = 1' -0" SCALE: (11 "X17"):3/4" = 1' -0" ASCO 7000 SERIES AUTOMATIC TRANSFER SWITCH (30 -230 AMPS) FLOOR LEVEL GENERATOR HOUSING TOP OF GENERATOR FUEL TANK GROUND LUG MOUNTING STUDS RECEIVED CITY OF TUKWILA AUG 20 2001 PERMIT CENTEF 3 3/4 "0 HILTI EXPANSION BOLTS, 4" MIN. EMBED (TYP) TOTAL OF (4) BOLTS MIN. VIBRATION ISOLATION TO BE SUPPLIED BY GENERATOR MANUFACTURER, INSTALLED BY CONTRACTOR 1 t. Together with NDCTI 105.15 WILLOWS 50 90 SORT 100 REWORD, WA 91051 10020 42317.1500 PACIFIC TELECOM SERVICES, LLC 300 ruw Avenue S. Suite 630 5•011.. WA. 06104 P5.w, (106) 3421000 Fm (206) 903 -031 4072 THOMAS R. HOLLAND STATE OF WASHINGTON 0 0 0 JOB # WA0234 REVISION -3 GENERATOR AND ECU PMENT DETAILS DRAWING # A -3 0 ECT TUKWILA, WA 98 I 88 545 ANDOVER PARK W db I HI. . J 1 831 j ai REVISIONS '07/10/07 08/08/07 [LO /E i/eol ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION J Q .. ` 4 6" 1' -2" UNDISTURBED SOIL c\N O 1 -1" 12" MIN COMPACTED CRUSHED AGGREGATE #4 REBAR ® 12" O.C. EACH WAY 0 MID DEPTH 5 -0" PROPOSED NEXTEL 40kw SINGLE SIDE SERVICE GENERATOR (ABOVE) CONDUIT STUB -UP PROPOSED NEXTEL 5' -0" X 8' -O" CONCRETE PAD SCALE: (24"X36"):1 " -1' -0" SCALE: (11"X177:1/2 " =1' -0" FOOTING DETAIL SCALE: (24'X36'):1- 1/2 "=1' -0" SCALE: (11'X17'):3/4 " =1' —O' C- 1' -2" 3/4 "0 HILTI EXPANSION, 4" MIN. EMBED (TYP) TOTAL OF (4) BOLTS MIN. GENERATOR CONNECTION 3/4" CHAMFER (TYP) #3 STIRRUPS 0 24" O.C. 2 v M T 9 15 4 3 \-- THICKED -EDGE CONC PERIMETER FOOTING 12" MIN COMPACTED CRUSHED AGGREGATE COMPACTED TO 95% DRY UNIT WT PER ASTM D1557 6" THK CONC SLAB W/ #4 BAR 0 MID 0 12" 0.C. E.W. THICKED -EDGE CONCRETE FOOTING z w 0 N ! / 1' -6" OVERLAP 2' -0" #4 CORNER BAR 0 TOP & SOT 8' -0" FOUNDATION OUT -TO -OUT 6" THK CONC SLAB W/ #4 BAR 0 MID 0 12" 0.C. E.W. CONCRETE PAD SECTION SCALE: (24")35'):1" =1' -0" SCALE: (11'X17"):1/2 " =1' —O" NOTE: REFER TO ARCHITECTURAL DRAWING FOR LOCATIONS CONCRETE PAD SCALE: (24'X36'):3/4" = 1' —O' SCALE: (11 "X17 "): 3/8" = 1' -0" 3/4" CHAMFER (TYP) RECEIVED O rry op TUVCWItA AUG 2 0 2001► PEEWI C i o REVIEWED FOR ' ODE COMPLIANCE ° P P ? c,J, SEP 12 2007 City Of Tukwila BUILDING DIVISION 2 1 Sprint. Together with NE7(TE 10545 WILLOWS 00 M0 sum 100 0[0110X0. WA 90052 1410•2: 42537.7400 PACIFIC TELECOM SERVICES, LLC 366 11W Memo S. AMID 350 see114. WA. 0•104 Ph/1.w (206) 342 -9000 Fm (206) 903 - 6513 4072 THOMAS R. HOLLAND STATE OF WASHINGTON Cr) GE JOB # WA0234 REVISION RED TECT -4 NERATOR PAD DETAILS DRAWING # A -4 0 TUKWILA, WA 98188 545 ANDOVER PARK W de HI g m J 1831 va j REVISIONS 07/10/07 08/08/07 Ito/El/801 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION m o FENCING NOTES 1. CONTRACTOR TO CONTACT ALL UTILITIES FOR LOCATION OF ALL UNDERGROUND SERVICES PRIOR TO CONSTRUCTION. 2. ALL FENCING MATERIAL SHALL BE AS FOLLOWS: — NO. 1 CEDAR FOR: 1" X 6 ", 2" X 4" 3. ALL NAILS AND HARDWARE TO BE GALVANIZED OR ALUMINUM. 4. COLOR OF STAIN FOR FENCING MUST BE APPROVED BY THE CONSTRUCTION MANAGER AND BLEND WITH EXISTING LANDSCAPE OR ADJOINING BUILDINGS. 5. PLYWOOD SHALL BE STRUCTURAL GRADE PRESSURE TREATED. 6. MINIMUM CONCRETE STRENGTH SHALL BE 2500PSI AT 28 DAYS. 7. GATE POST, CORNER, END OR PULL POST 3" NOMINAL (3.5" 0.0.) SCHEDULE 40 PIPE, FOR GATE WIDTHS UP TO 6' OR 12' FOR DOUBLE SWING GATE PER ASTM —F1083 8. LINE POST: 2" (2 3/8" O.D.) SCHEDULE 40 ASTM— F1083. 9. TOP RAIL AND BRACE RAIL: 1 1/2" (1.9" O.D.) PIPE. SCHEDULE 40 ASTM— F1083. INSTALL BRACE AT ALL CORNER LOCATIONS & ADJACENT TO GATES. 10. GATE FRAME: 1 1/2" (1.9" O.D.) SCHEDULE 40 ASTM— F1083. 11. BARB WIRE (WHEN SPECIFIED): DOUBLE STRAND 12 GA. 1/2" 0.0. TWISTED WIRE TO MATCH W /FABRIC, 14 GA. 4PT. BARBS SPACED ON APPROX. 5 CENTERS. 12. BARB WIRE GATE GUARDS (WHEN SPECIFIED) SHALL BE FITTED WITH DOME CAPS. 13. BARB WIRE SUPPORT ARMS (WHEN SPECIFIED) SHALL BE PRESSED STEEL COMPLETE WITH SET BOLT AND LOCK WIRE IN THE ARM. 14. GATE POSTS SHALL BE EXTENDED 12 INCHES, INCLUDING DOME CAP, TO PROVIDE ATTACHMENT OF BARB WIRE. 15. GATE FRAMES SHALL HAVE A FULL— HEIGHT VERTICAL BRACE, AND A FULL —WIDTH HORIZONTAL BRACE, SECURED IN PLACE BY USE OF GATE BRACE CLAMPS. 16. GATE HINGES SHALL BE MERCHANTS METAL MODEL 64386 HINGE ADAPTER WITH MODEL 6409, 180 — DEGREE ATTACHMENT OR APPROVED EQUAL. 17. ALL POSTS EXCEPT GATE POSTS SHALL HAVE A COMBINATION CAP AND BARB WIRE SUPPORTING ARM (WHEN SPECIFIED). 18. ALL CAPS SHALL BE MALLEABLE IRON, DOME OR ACORN SHAPED AS REQUIRED BY PIPE SIZE. 19. WHERE THE USE OF CONCERTINA HAS BEEN SPECIFIED, 24 — INCH DIAMETERS COIL. BARBED TAPE, STAINLESS STEEL, CYCLONE FENCE MODEL G8P TO TYPE 111 SHALL BE FURNISHED. IT SHALL BE SUPPORTED ABOVE THE TOP RAIL BY USE OF (6) BARBED WIRE ARMS POSITIONED ATOP EACH LINE /CORNER POST. 20. UNLESS NOTED OTHERWISE, ALL FENCING COMPONENTS MUST BE HOT DIPPED GALVANIZED. 1x4 CEDAR FENCE PALES NAILED WITH (2) 1 1/2" GALV. STAPLES PER RAIL (TYP OF 2 RAILS PER POLE) (TYP) P.T. 2x4 STRINGER P.T. 4x4 FENCE POST SIMPSON FB24 FENCE BRACKET (TYP OF (4) EACH POST) CONCRETE PEIR .' UI 11111 IN mum r. FENCE POST ba mom 7., SCALE: (24 "X36 "): 1/2" = 1' -0" SCALE: (11"X17"):1/4" = 2 4x4 PT CEDAR FENCE POST EXISTING GRADE CONCRETE PEIR GALV. STEEL HASP. PROPOSED 4' GATE CONCRETE PEIR TOP OF GRANULAR "A" MATERIAL EXISTING GRADE —� CONCRETE PEIR -_ GATE FOUNDATION SCALE: (24"X367: 3/4" '- 1' -0" SCALE: (11"X17"):3/8" �= 1' -0" 4x4 PT CEDAR FENCE POST DATIONIIENNED FOR t . it yy " _ SE P 12 2001 City Of IOW D S".� FENCE FOU SCALE: (24"X36"):3/ SCALE: (11"X17 "):3 /8 1 1 -0" 12J PT 1X4 CEDAR FENCING 6 PT 1X4 CEDAR FENCING #5 REBAR ® 36" LONG 2 PER TIMBER 1 -0" DA. P.T. 2x4 RAILS (TYP) 1x4 CEDAR FENCING P.T. 4x4 FENCE POST ■ CORNER CONNECTION SCALE: (24"X36"):1 -1/2" - 1' -O" SCALE: (11"X17"):3/4" - 1' -0" GATE CONNECTION SCALE: (24"X36"):1 -1/2" SCALE: (t1"Xt7 "):3/4" - 1' -0" 3 HEAVY DUTY GALV. STEEL GATE HINGES (TYP) PROPOSED WOOD FENCE WITH POST ® 6' -0" O.C. (TYPICAL) 4" PALES (TYP BEYOND) WOOD FENCE SCALE: (24"X361: 1/2" = 1' -0" SCALE: (11 "X17 "): 1/2" = 1' -0" SIMPSON FB24 (TYP) GATE (IN OPEN POSITION) FENCE SIMPSON FB24 (TYP) P.T. 2x4 RAILS (TYP) 1x4 CEDAR FENCING P.T. 4x4 FENCE POST RECEIVED CITY OF TUKWILA AUG 2 0 2007 PER4:1T CEMTES 5 3 PROVIDE 4" X 6" P.T. TIMBER TO RETAIN WASHED CRUSHED STONE IN COMPOUND. TOP OF TIMBER SHALL BE PLACED 4" ABOVE GRANULAR "A" MATERIAL. OUTSIDE COMPOUND RAMP GRANULAR "A" MATERIAL AT 6:1 SLOPE TO TOP OF TIMBER TO MINIMIZE TRIPPING HAZARD. Sprint. Together with NEJCTE 16546 WWW*6 96 M1 sun 100 6E0■0410. WA 60051 MOM, 425.17.7400 T� PACIFIC TELECOM SERVICES, LLC 596 MN Aw"w 6. 6"66 690 S"°I6ti WA 96104 PMS"= (206) 342 -6000 E6= (206) 603 -6611 4072 THOMAS R. HOLLAND STATE OF WASHINGTON Cr, O A JOB # WA0234 REVISION FENCE DETAILS TEREC HITECT -5 DRAWING # A -5 0 545 ANDOVER PARK W TUKWILA, WA 98188 db' [Hl x x I— I— CO m 0 3l l J i REVISIONS Ico /oI /col LO /EI /80 LO /80/80 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION Q m o GENERATOR FRAME BOND NOT TO SCALE ❑ ❑ GENERATOR FRAME TWO HOLE BOLTED GROUND LUG, 5S HDW #2 AWG TINNED WIRE NOTE PREP SURFACE BEFORE GROUNDING - USE NO -OX BETWEEN LUG AND STEEL. USE SAME COLOR TOUCH UP PAINT TO PREVENT RUST. ❑ ❑ ❑ 11111111111111 11111111111111 1101111111 mime 11111 PROPOSED NEXTEL 40kw DIESEL GENERATOR AND FUEL TANK ON 5' -0" X B' -0" CONCRETE PAD GENERATOR FRAM BO1 b 3E DETAIL yS SHEET t SEP 12. 2001 City OfT1".11 4 PROPOSED NEXTEL A MINT _Ma SHELTER (FIELD VERIFY EXACT LOCATION) PROPOSED #2 AWG ATS CASE BOND APPROX. LOCATION OF EXISTING NEXTEL GROUND RING (FIELD VERIFY EXACT LOCATION) APPROX. LOCATION OF EXISTING NEXTEL HALO (FIELD VERIFY EXACT LOCATION OF OC c4� i 1\ NOTES: 1. POWER INTERRUPTION IS ALLOWED ONLY UNDER THE FOLLOWING CONDITIONS; OUTSIDE OF THE MORNING AND AFTERNOON DRIVE TIMES, CUT DURATION MUST BE GUARANTEED TO BE LESS THAN 2 HOURS MAX. IF THIS CAN NOT BE GUARANTEED STAND -BY POWER MUST BE CONNECTED OR INTERRUPTION MUST BE PERFORMED DURING THE MAINTENANCE WINDOW. 2.EXISTING DUPLEX GFI ON THE GENERATORS SHALL BE CHANGED OUT TO A NON -GFl OUTLET TO AVOID LOSS OF POWER TO THE BATTERY CHARGER AND BLOCK HEATERS. NON-GFI OUTLET SHALL BE SERVICED BY ONE 20AMP CIRCUIT IN FLEX CONDUIT. SCALE: (24' X 36") 1/2 " -1' -0" SCALE (11' X 17") 1/4" -1' -0" 2 18" 1 6 0 2' GROUNDING PLAN 2 GENERAL GROUNDING NOTES: 1. EXOTHERMIC WELD ALL CONNECTIONS TO BURIED GROUND RING WITH PARRALLEL TAP WELDS, USE SHORT RODS WHERE STANDARD GROUND RODS ARE NOT USED, SEE CABLE TO CABLE DETAIL. 2. MAKE ALL GROUNDING CONNECTIONS AS SHORT AS POSSIBLE, MINIMUM BENDING RADIUS IS 8 ". 3. CLEAN ALL SURFACES AND BRUSH WITH BRONZE BRUSH PRIOR TO MAKING GROUND CONNECTIONS, PAINT ALL EXOTHERMIC WELDS TO GALVANIZED OBJECTS WITH GALVANIZE PAINT, USE NO -OX COMPOUND WITH METAL TO METAL CONNECTIONS. 4. INSTALL 5/8" X 10' COPPER CLAD STEEL GROUND RODS IN LOCATIONS SHOWN, DISTANCE 10' -0" MINIMUM TO 15' -0" MAXIMUM BETWEEN RODS. 5. GROUND SYSTEM MUST BE INSPECTED BY CONSTRUCTION MANAGER PRIOR TO BACKFILL, PROVIDE 24 HOURS NOTICE. 6. ALL BONDS SHALL BE #2 AWG BARE, THINNED, SOLID COPPER UNLESS OTHERWISE NOTED. 7. THE GENSET SHALL BE GROUNDED TWICE IN DIAGONAL CORNERS. ONE GROUND TO THE TANK FRAME AND THE SECOND TO THE GENERATOR ENCLOSURE FRAME. IT IS ACCEPTABLE TO GROUND THE TANK AT BOTH LOCATIONS WITH A JUMPER FROM THE TANK TO THE GENSET ENCLOSURE. THESE GROUNDS SHALL BE ON THE OUTSIDE OF THE UNIT TO BE VISIBLE BY ALL. GROUNDING PLAN NOTES: 6) C) PROVIDE AND INSTALL #2 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM THE GENERATOR FRAME TO THE GENERATOR GROUND ROD. PROVIDE AND INSTALL A 5/8" X 10' -0" COPPER CLAD STEEL GROUND ROD APPROXIMATLEY 24" FROM GENERATOR PAD, FOR CASE BOND. PROVIDE AND INSTALL A #2 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM THE GROUND ROD TO THE NEAREST POINT ON THE EXISTING GROUND RING. PROVIDE AND INSTALL #2 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM THE FUEL TANK FRAME TO THE FUEL TANK GROUND ROD. ATS NOTES: IF THE ATS IS INSIDE THE CELL SITE ENCLOSURE, THE ATS CASE SHALL BE BONDED TO THE HALO GROUND RING INSIDE THE ENCLOSURE WITH A #6 AWG COPPER WIRE. IF THE ATS IS OUTSIDE THE ENCLOSURE, IT SHALL BE BONDED TO THE EXTERNAL GROUND RING WITH A #2 AWG SOLID TINNED COPPER WIRE. THE SURGE ARRESTORS DESCRIBED IN THIS MOP ARE TO BE MOUNTED ON THE MOUNTING PLATE SOLD BY THE MANUFACTURER. THEY MAY BE GROUNDED IN ONE OF THREE WAYS: 1. IF THE ARRESTOR MOUNTING PLATE IS MOUNTED ON THE TELCO BOARD AND IF THE TELCO GROUND BAR IS BONDED TO THE EXTERNAL GROUND RING, THE PLATE MAY BE BONDED TO THE TELCO GROUND BAR WITH A #2 AWG INSULATED STRANDED COPPER WIRE AND SUITABLE COMPRESSIONOTYPE 2 -HOLE LUGS. 2. IF THE ARRESTOR PLATE IS NOT MOUNTED ON THE TELCO BOARD, BOND IT DIRECTLY TO THE EXTERNAL GROUND RING WITH A #2 AWG SOLID TINNED COPPER WIRE. USE A PVC CONDUIT THROUGH THE SHELTER WALL AT A 45 DEGREE ANGLE TO ALLOW THE GROUND LEAD TO EXIT THE SHELTER FOR BONDING TO THE EXTERNAL GROUND RING. 3. IF AN EXISTING #2 AWG GROUND CONDUCTOR EXISTS THE SHELTER (TO THE EXTERNAL GROUND RING) WITHIN 2F1 OF THE MOUNTING PLATE LOCATION, THE PLATE MAY BE BONDED USING A #2 AWG INSULATED STRANDED CONDUCTOR WITH A COMPRESSION TYPE "C" TAP AND A SUITABLE COMPRESSION TYPE 2 HOLE LUG. MAKE ALL CONNECTIONS TO THE ATS CASE, THE GENERATIOR FRAME, THE EXTERNAL FUEL TANK (IF PRESENT AND IF SUPPORTED BY THE MANUFACTURER) AND THE SURGE ARRESTOR MOUNTING PLATE WITH SUIABLE 2 -HOLE COPRESSION -TYPE LUG RAND STAINLESS -STEEL SCREWS, STAR -TYPE LOCK WASHERS AND NUTS. REMOVE PAINT AT THE POINT WHERE THE COMPRESSION LUG CONTACTS THE MATING METAL SURFACE IN QUESTION TO ENSURE A GOOD METAL -TO -METAL CONTACT. APPLY ANTIOXIDANT TO THE MATING SURFACES. ENSURE THAT ALL UNDERGROUND OR OUTDOOR CONNECTIONS TO A GROUNDING SYSTEM ARE EXOTHERMICALLY WELDED (CAD- WELDED). PERFORM ALL GROUNDING WORK IN ACCORDANCE WITH STDS 2976175, CONSTRUCTION STANDARDS ELECTRICAL NOTES 1 10845 WILLOWS 10 N1 SUIT[ toe REDMOND. MA 01452 MOW. 425.2747400 PACIFIC TELECOM SERVICES, LLC sea Mn, A...» S. S,w• 050 5.0X1., WA. 10104 Mona (200) 542 -0030 ram (201) 005 -151: 40 Together with NTDCTI THOMAS R. HOLLAND STATE OF WASHINGTON s GISTEREC TECT Cr) N O GROU ELE JOB # WA0234 REVISION II DING PLAN AND TRICAL NOTES DRAWING # E -1 0 dv1 r I-- 10 101 +/- o +/- GND 0 a GND 1O I O 101 GND N a GND I O 1 +/- L : +/- K 0 GND 0 a GND O 1 - � 1010 +/- 0 - +/- cc 0 GND 0 a GND 1 o1 O 0 +/- u ~ o +/- GND N a GND O 0 +/- 0 1- cc 0 GND 0 a GND I 0 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION' O 0 +/- o o +/- GND 0 a GND O 10 Q m o o o +/- L.' o +/- GND 0 a GND O 10 o I +/- u '- +/- D GND 0 a GND o Io o Io +/- o o +/- v GND GND 0 i a O 10 O 10 +/- u o +/- GND N a GND Po I0 O 10 +/- 0 o +/- GND 0 a GND O 1 0 I0I0 +/- o o +/- cc GND N a GND I0I0I oI +/- o - +/- GND 0 a GND o lo 1 O 10 +/- u o +/- GND = n a GND O 1 1010 +/- u o +/- GND 0 a GND 0 -1 1 0 +/- L +/- GND a E GND O 1 0 =1 I +/- 0 Q +/— 0 0 a GND °1° 1 " GND dv1 r I-- IHi1 m m 18311 SNOISIA921 I 07/10/07 08/08/07 1L0 /W80 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION' Q m o OW BATT VOLTAGE HIGH BATT VOLTAGE LOW ENGIN TEMP ALARM EXPANSION BOARD 1 9 NC - -BLK K5 10 II 11 NC �-- K6 I 12 C H- 13 NC K7 14 C H- 15 NC K8 16 C T WHT- 21 NC I BRN — FAULT #1 I 22 C —BLU - 23 NC 1.-RED— FAULT #2 24 C �GRN— WEAK BATTERY LEAK DETECT MQ POWER DIESEL PADMOUNT GENERATOR SET REMOTE START ENGINE RUNNING 25 FAULT #3 26 35% LOW FUEL 27 FAULT #4 28 29 FAULT #5 30 CONTROL PANEL NC NC C GENERATOR FAILURE 31 FAULT OUT #5 32 F L J RED —BLKJ RED—" C 1-1--GRN- NC 1 —IBRN -1 C FBLU-- I NC 1- -BLK - WHT - STRANDED WIRE STRANDED WIRE STRANDED WIRE NOTES: ASCO 7000 ATS L5 SOLID WIRE / BLK WHT RED GRN BRN BLU BLK WHT RED GRN BRN BLU BLK WHT —RED BRN —BLU 1. SEE DETAIL 1, SHEET E -3 FOR ATS CABLE SCHEDULE 2. CONTRACTOR TO PROVIDE A NEW 66 BLOCK IF REQUIRED, WITH FURTHER ROUTING TO THE RBS EQUIPMENT CABINET AND LEFT WITH A 2' COIL OF WIRE. ALARM CABLING IN THE TELCO CABINET SHALL BE INSTALLED IN A NEAT FASHION WITH A 6' SERVICE COIL CONTRACTOR SHALL NOT MAKE PUNCH DOWNS ON THE TELCO BOARD 66 BLOCK WHT /BLU (UTILITY POWER) BLU /WHT WHT /ORG (GENERATOR POWER) - ORG /WHT WHT /GRN (TRANSFER SW POSTION) - GRN /WHT WHT /BLU (GENERATOR FAILURE) BLU /WHT WHT /ORG (ENGINE RUNNING) - ORG /WHT —, WHT /GRN (<35% FUEL REMAINING) GRN /WHT WHT /BLU (GENERATOR r MINOR) BLU /WHT WHT /ORG (LEAK DETECTED) ORG /WHT -_ 9 SOLID WIRE 7 SOLID WIRE 8 SOLID WIRE J / / WHT /BLU \ BLU /WHT WHT /BLU BLU /WHT WHT /ORG ORG /WHT O 0 43 rd 0 18 r ' o 44r� 0 19 r--1 0 45 0 0 20 0 0 WHT /GRN 46 r� 0 GRN /WHT 21 r 0 WHT /ORG 47 r' 22 r WHT /GRN - — 48 0 GRN /WHT 23 r o 49 = = 24 0 = 50 0 0 25 0 0 ORG /WHT CODE CO' z SEP A_ 22aa1 Cif Of ,�,� 6U lg 5 I r y 36 0 0 0 11 = = 0 37 0 = 0 12 0 = 0 I 38 l 0 13 0 0 0 . 39 3 /WHT - 14 r�i 0 0 T /BLU 40 r- 0 = 15 r l 0 41 0 = = 16 = 0 0 L_ L 17 1 0 37r 12 � 38 0 0 L SCALE: (24'X36'): NOT TO SCALE SCALE: (11'X177: NOT TO SCALE SYSTEM BLOCK 0 0 0 USER BLOCK 0 0 11 0 0 37 0 0 12 0 0 38 0 0 17 = = 43 H 0 0 18 o I 44 0 0 19 ....." O 0 45 I = 0 20 I = = 46 I = = 21 EJ = = 47 = = 22 ..,... = 048,1 = = 23 I 0 0 49 -. I = = 24 s� 0 0 50 I O 0 25 .a. I 1 0 0 0 0 0 0 0 0 0 0 0 36 11 37 12 38 13 39 14 40 15 41 16 cc / Ov- s. p11G 20 26 2EC�F��t"( OE�ITCR MQ POWER ALARM WIRING — IDEN 1 J _ I H 1 Sprint. Together with NE7(TE ,051! WILLOWS ID Id SUITE WO AMMO.. WA 96052 MOM4 4211.273.7400 PACIFIC TELECOM SERVICES, LLC WS r>"1 A.a.w. S. Sul., 650 Say..... WA. N104 Maw. (206) 142 -0000 9® (206) 905 -SS1: 407 THOMAS R. HOLLAND STATE OF WASHINGTON N O -2 E JOB / WA0234 REVISION C STEREO TECT MO POWER DIESEL GENERATOR ALARM WIRING - IDEN DRAWING # E -2 0 545 ANDOVER PARK W TUKWILA, WA 98188 CABLE NUMBER FROM TO MANUFACTURER PART NUMBER CONDUCTOR COUNT AND GAUGE USE 1 GENERATOR TERMINAL STRIP ATS BELDEN 8442 2 (UNSHIELDED) 22 AWG ATS GENERATOR START SIGNAL TO GENERATOR 2 GENERATOR TERMINAL STRIP SURGE ARRESTORS BELDEN 9421 8 (UNSHIELDED) 22 AWG GENERATOR ALARMS TO SYSTEM BLOCK SURGE ARRESTOR 3 GENERATOR TERMINAL STRIP I SURGE ARRESTORS BELDEN 8442 2 (UNSHIELDED) 22 AWG FUSED 12 VDC TO SYSTEM BLOCK SURGE ARRESTOR 4 GENERATOR TERMINAL STRIP SURGE ARRESTORS BELDEN 9421 8 (UNSHIELDED) 22 AWG GENERATOR ALARMS TO SYSTEM BLOCK SURGE ARRESTOR ± ( 1 5 ATS l SURGE ARRESTORS BELDEN 9421 8 (UNSHIELDED) 22 AWG ATS ALARMS TO SYSTEM BLOCK SURGE ARRESTOR 7 SURGE ARRESTORS TELCO BOARD SUPERIOR / ESSEX 12- 204 -37 8 (SOLID CONDUCTOR) 22 AWG GENERATOR ALARM OUTPUTS FROM SYSTEM BLOCK SURGE ARRESTOR TO SYSTEM BLOCK 8 SURGE ARRESTORS TELCO BOARD SUPERIOR / ESSEX 12- 204 -37 8 (SOLID CONDUCTOR) 22 AWG GENERATOR ALARM OUTPUTS FROM SYSTEM BLOCK SURGE ARRESTOR TO SYSTEM BLOCK 9 �SURGE ARRESTORS TELCO BOARD SUPERIOR / ESSEX 12- 204 -37 8 (SOLID CONDUCTOR) 22 AWG ATS ALARM OUTPUTS FROM SYSTEM BLOCK SURGE ARRESTOR TO SYSTEM BLOCK dV ± w ± m m m GND D ° a GND GND D ° m GND U) a N ± w ± w ± 07/10/07 08/08/07 CO /p/80 GND D (n it GND a ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION ± w ± ± w ± GND D cc GND D cc GND n N a B ± w ± w ± GND D it GND N a a ± w ± ± GND D cc GND N a ± w ± GND D GND D () ° a GND a (n 0- dV ± w ± m m m 0 F- GND D ° m GND d4 N a ± w ± 07/10/07 08/08/07 CO /p/80 GND D CC GND ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION (n a ± w ± GND D cc GND n U) a ± w ± GND D ° a GND (n a ± w ± GND D it GND N a ± w ± GND D cc GND (n 0- dV m m m d4 jai REVISIONS 07/10/07 08/08/07 CO /p/80 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION Q m o UTILITY POWER [OPTION 1 BG] (CLOSED WHEN POWER ON) GENERATOR POWER [OPTION 189] (OPEN WHEN POWER ON) TRANSFER SWITCH POSITION (CLOSED FOR UTILITY) ASCO 7000 SERIES TRANSFER SWITCH BLK WHT BLK WHT GRN -' RED GRN RED BLU - BRN -' BLU BRN 5 STRANDED WIRE BLK 6 STRANDED WIRE • WHT SCALE: (24 "X367: NOT TO SCALE SCALE: (11'X171: NOT TO SCALE POLYPHASER IX -6DC56 ARRESTOR WHT RED GRN BRN BLU BLK RED GRN • BRN BLU NOTES: 1. SECOND POLYPHASER IS PROVIDED FOR ENVIRONMENTAL CONTROL SYSTEM (TO BE CONNECTED BY OTHERS). 2. ALL POLYPHASERS SHALL BE MOUNTED W /IN THE EXISTING TELCO CABINET. IF THERE IS NOT SUFFICIENT ROOM TO DO THIS, THE POLYPHASER(S) SHOULD BE MOUNTED W /IN A NEW 18 "X18 "X12" NEMA RATED ENLCOSURE MOUNTED ON THE EXISTING H- FRAME. 3. POLYPHASERS HAVE SPECIFIC WIRE IN /WIRE OUT ROUTING. THIS MUST BE FOLLOWED BY INSTALLATION PERSONNEL. 4. POLYPHASER QUANTITY REQUIREMENTS; -CDMA SITES RECEIVE 2, ONE MOUNTING PLANE FOR GENERATOR ALARMS ONLY. NO POLYPHASERS BETWEEN ATS AND BTS. - IDEN SITES RECEIVE 4, ONE MOUNTING PLANES, TWO FOR GENERATOR ALARMS, ONE FOR ATS ALARMS. - CO -HAB (IDEN AND COMA) RECEIVE 4, ONE MOUNTING PLANE, ALL GENERATOR ALARMS GO TO THE IDEN SHELTER /CABINET, AND THE ATS ALARMS (FOR COMA ONLY) DO NOT REQUIRE POLYPHASERS - STRAIGHT THROUGH TO BTS (RADIO CABINET). -- IN CO -HAB INSTANCES 2 ATS WILL BE USED. THE IDEN ATS USES POLYPHASERS BETWEEN IT AND FINAL PUNCHDOWN. 5. ALL ALARMS GO TO THE IDEN SIDE ON COHAB SITES. ATS ALARMS ALSO GO TO THE CDMA SIDE. NO POLYPHASERS ARE REQUIRED FOR THE ATS ALARMS FOR COMA. ATS ALARM WIRING — IDEN 2 WHT /BLU BLU /WHT — WHT /ORG —' ORG /WHT WHT /GRN GRN /WHT ■ (UTILITY POWER) (GENERATOR POWER) (TRANSFER SWIT H POSITION) 9 SOLID WIRE L_ WHT /BLU 11 0 BLU /WHT --T 12 r-1-1 CZ 3 80 r j— WHT /ORG 21= 47r ORG /WHT 22 t"---, WHT /GRN I 48 GRN /WHT -- 3 t ‘-t 23' 4 • 9 0 I 24= 5 0= 2 5 0 SYSTEM BLOCK 0 = 011 00 037 0 = 012 0 = 038 0 O 0 0 0 0 0 O 0 0 0 0 21 m=7147 0 22 = 48 =23 C=149 =124 = 50 0 25 j 1 I t REVIEWED FOR CODE COMPLIANCE SEP 12 2007 City Of Tukwila BUILDING DIV151. V ATS CABLE SCHEDULE SCALE: (24'X36"): NOT TO SCALE SCALE: (11"X17"): NOT TO SCALE RECEIVED err( OF TUKWILA AUG 20 2007i PERMIT CcJIT A 1 Together with NEORE 1054' WN1OW3 RD NC 50111 100 N OWA0. WA 59052 1.1l05L 423.I7117400 PACIFIC TELECOM SERVICES, LLC 509 1St Avww4 0. Sotto 050 S3404, WA. 59104 Nam (200) 342 -5000 Fan (200) 903 -0512 407 GI RED TECT THOMAS R. HOLLAND STATE OF WASHINGTON 0 `J N O E JOB # WA0234 REVISION -3 ATS CABLE SCHEDULE AND ATS ALARM WIRING - IDEN DRAWING # E -3 0 TUKWILA, WA 98188 545 ANDOVER PARK W d v IHi - � m m J J LI Li i REVISIONS 08/08/07 08/13/07 ISSUED FOR PCD REVIEW ISSUED FOR PCD REVIEW ISSUED FOR CONSTRUCTION m o NOTES: 1. POLYPHASER SURGE PROTECTORS SHALL BE MOUNTED NEAR THE ATS AND CONNECTED TO NEAREST GROUND WIRE EXITING THE SHELTER WITH A #6 WIRE WITH A TWO HOLE LUG CONNECTION. 2. 3. 4. ALL POLYPHASERS SHALL BE MOUNTED W /IN THE EXISTING TELCO CABINET. IF THERE IS NOT SUFFICIENT ROOM TO DO THIS, THE POLYPHASER(S) SHOULD BE MOUNTED W /IN A NEW 18"X18"X12" NEMA RATED ENLCOSURE MOUNTED ON THE EXISTING H -FRAME POLYPHASERS HAVE SPECIFIC WIRE IN/WIRE OUT ROUTING. THIS MUST BE FOLLOWED BY INSTALLATION PERSONNEL POLYPHASER QUANTTIY REQUIREMENTS; -CDMA SITES RECEIVE 2. ONE MOUNTING PLANE FOR GENERATOR ALARMS ONLY. NO POLYPHASERS BETWEEN ATS AND BTS. - IDEN SITES RECEIVE 4, ONE MOUNTING PLANES, TWO FOR GENERATOR ALARMS, ONE FOR ATS ALARMS. - CO -HAB (IDEN AND CDMA) RECEIVE 4, ONE MOUNTING PLANE, ALL GENERATOR ALARMS GO TO THE IDEN SHELTER /CABINET. AND THE ATS ALARMS (FOR CDMA ONLY) DO NOT REQUIRE POLYPHASERS - STRAIGHT THROUGH TO BTS (RADIO CABINET). -- IN CO -HAB INSTANCES 2 ATS WILL BE USED. THE IDEN ATS USES POLYPHASERS BETWEEN IT AND FINAL PUNCHDOWN. 5. ALL ALARMS GO TO THE IDEN SIDE ON COHAB SITES. ATS ALARMS ALSO GO TO THE CDMA SIDE. NO POLYPHASERS ARE REQUIRED FOR THE ATS ALARMS FOR L1 /L2 UTILITY CO. DISCONNECT CHASSIS (AND H- FRAME) BOND CHASSIS BOND SHELTER DISCONNECT "UTILITY ELECTRICAL GROUND ROD* ✓3 INCHES ABOVE SURFACE FOR INSPECTION ✓EXOTHERIC BOND TO EXTERIOR GROUND RING N I "GENERATOR ELECTRICAL GROUND _ "EXOTHERMIC BONO TO EXTERIOR GROUND RING ATS /MTS EMERGENCY NORMAL *IF UTILITY DISCONNECT 15FT OR LESS FROM SHELTER, COMMON ROD PERMITTED, OTHERWISE, TWO DISTINCT RODS. * *BOND UTILITY DISCONNECT NEUTRAL/GROUND TO SHELTER GROUND IF UTILITY DISCONNECT IS WITHIN SHELTER PERIMETER, OTHERWISE, NOT BOND. SCALE: (24'X361: NOT TO SCALE SCALE: (11'X177: NOT TO SCALE O CHASSIS BOND TO HALO (INTERIOR OR EXTERIOR (EXTERIOR) ✓SHELTER ELECTRICAL GROUND ROD* "3 INCHES ABOVE SURFACE FOR INSPECTION "EXOTHERMIC BOND TO EXTERIOR GROUND RING NEUTRAL GROUND BOND GENERATOR LOAD CENTER L1 /L2 CHASSIS BOND TO HALO 3 UTILITY DISCONNECT EMERGENCY POWER INPUT FROM PADMOUNT GENERATOR GENERATOR CHARGE CONNECTION ALARM / CONTROL CONNECTION APPLETON CONNECTOR 1 4J — ALL GENSET CONNECTIONS VIA STUB -UP AREA GENERATOR CHARGER /HEATERS POWER GENSET POWER OUT ALARM /STATUS /CONTROL ATS • TS 1GRQ11N1 3 � + rr . °143.41:1;a:7°' . G NSET/TK G UND ROTA 3. SE A"11 LOAD CENTER -�—� TO SITE +► LOADS ALARM Ho. TO FACILITY .... L_._._._. -. SURGE ALARM BLOCK PROTECTORS (PROVIDED I I WITH SHELTER) — J SURGE SUPPRESSOR NOTES: 1. IF PORTABLE IS REQUIRED IN ADDITION TO PADMOUNT GENERATOR, ADD PLANNING AS REQUIRED TO ADD MANUAL TRANSFER SWITCH AND APPLETON CONNECTOR IN EMERGENCY BUS FROM ATS (SHOWN IN DOTTED LINES). GENSET SINGLE -LINE DIAGRAM SCALE (24'X361: NOT TO SCALE SCALE: (11'X17'): NOT TO SCALE SITE LOAD CENTER ATS* SITE POWER ♦ MULTI -PAIR ALARM CABLE SCALE: (24'X36'): NOT TO SCALE SCALE: (11'X17'): NOT TO SCALE POWER SURGE PROTECTOR RECEIVED CITY OF TUKWILA AUG 20 2007 PERMIT CETJTETL UTILITY MAINS DISCONNECT ALARM 66 BLOCK CONDUIT SINGLE -LINE DIAGRAM UTILITY POWER IN TO IMU 2 1 0 Together with NMI 1054 MUMS 90 t Sure 100 900140■0. WA NOS, NOW.: 425.276.9400 PACIFIC TELECOM SERVICES, LLC SN ,u., Avenue S. sane 650 S.at14. WA. 96104 PMnn (206) 342 -9000 Tart (2N) 905-661: 4072 THOMAS R. HOLLAND STATE OF WASHINGTON 1 N O TEREC TECT E -4 ELECTRICAL DETAILS JOB # DRAWING # WA0234 E - 4 REVISION I 0 QUASIMOTO 545 ANDOVER PARK W TUKWILA, WA 98188