Loading...
HomeMy WebLinkAboutPermit M07-184 - JAMBA JUICEJAMBA JUICE 17100 SOUTHCENTER PY SUITE 104 M07 -184 Parcel No.: 2623049081 Address: Suite No: 17100 SOUTHCENTER PT TUICW Tenant: Name: JAMBA JUICE Address: 17100 SOUTHCENTER PY, STE 104 , TUKWILA WA Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA Contact Person: Name: RALPH MILLESON Address: 234 5 AV S , EDMOND WA Contractor: Name: WILCOX CONSTRUCTION INC Address: 123 4TH AVE N , EDMONDS, WA Contractor License No: WILCOC* 194Q0 DESCRIPTION OF WORK: INSTALLATION OF DUCTWORK INSIDE OF TENANT SPACE, BATH FAN AND B -VENT. Value of Mechanical: $10,000.00 Type of Fire Protection: SPR] KLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 2 1 0 0 0 0 0 0 0 0 * *continued on next page ** M07 -184 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 774 -4185 Phone: 425 774 -4185 Expiration Date: 12/10/2007 M07 -184 10/15/2007 04/12/2008 Fees Collected: $269.58 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 10 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 10 -15 -2007 Permit Center Authorized Signature: Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us J1/4.).31 Avg- 1 • Permit Number: MO7 -184 Issue Date: 10/15/2007 Permit Expires On: 04/12/2008 Date: 10 (S I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the p rmance of work am authorized to sign and obtain this mechanical permit. Date: p / /c/c'7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -184 Printed: 10 -15 -2007 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 2623049081 Permit Number: M07 -184 Address: 17100 SOUTUCENTER PY TURIN Status: ISSUED Suite No: Applied Date: 08/24/2007 Tenant: JAMBA JUICE Issue Date: 10/15/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the doc: Cond -10/06 M07 -184 Printed: 10 -15 -2007 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (1FC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. M07 -184 Printed: 10 -15 -2007 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. I 11404 . F---; f1c cow Date: to ir 7607 M07 -184 Printed: 10 -15 -2007 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://www.atukwila.wa.us King Co Assessor's Tax No.. 11 V% Sowkc.Lv w Pawn cJ Suite Number: lb Y Tenant Name: "/kr44.9, R f. . New Tenant: Property Owners Name: UJ Z G 1>mopsrvr >-s Mailing Address: 4b 11 i 3 Cl *- ?hat SE Site Address: contact when your permit is ready to be issue Name: 2 tvty 4 tiny 1 tt s o ..-1 Day Telephone: Mailing Address: Zvi CI c il1TS, S o ak 4'1+ IAD ItiktAA h S City E -Mail Address: r M ■ 11 tr.s one U) 1 Cox Cwas 4*'oc on . CosesFax Number: ;RAL CONTRACTOR IN FORMATION Contractor Iaforinataoti far 1Vtechaaical (pg 4) forPtumbing and Gas P'iping'(pg Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: All plans must be wet stamped Company Name: Mailing Address: II P(. I bl4e.1G - 3 1 F . 12Fra, Oi L , i 11 A624.3 tuner City Day Telephone: P 11 ) ( 10 b E -Mail Address: Fax Number. 17 — 63% — '115 Contact Person: gr4 p 'N.A. k #C4 Q:MpplicationsWorms- Applications On LineV -2006 - Permit Application.doc Revised: 9 -2006 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Building Permit Mechanical Permit Nc Plumbing/Gas Permit. Public Works% ' ermit l Project Ice use City City Contact Person: Day Telephone: E -Mail Address: Fax Number: Floor: �y....Yes (4)4 State «i -7711 - 4 1 e5 t b t&or v ❑ ..No Zip I AM rb oZo State Zip 42.5- 17 y-Y1ff1 State State Zip City Day Telephone: Fax Number: Expiration Date: 1 76o16 State ,RECORD All plans Must e we=t stampe Company Name: Mailing Address: Zip Page 1 of 6 Valuation of Project (contractor's bid price): $ Z' S $ 0 6 0 Existing Building Valuation: $ Scope of Work (please provide detailed information): 1 **AT X w !bra Ge" s to f i trap omit o 1- 4- L £as LO P'' io e+U rs. i ht , &s 9 d0 sU f IM �T" I'�'1 I-v*1 ...Jr L� tT z 10 �`I►tf . N.i o tar ■ ,•.rC/I v o s-s �. roti g4 i - 0444 p s r4-t s [fir` 1 S ~Li Ft&+ r lac s Will there be new rack storage? ❑ Yes S. No If yes, a separate permit and plan submittal will be required. uare.Foo ualdtng Areas an tq3 Ott V— 13 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes; No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: k' Sprinklers E. Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Nr No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. QA Applications On Line\3.2006 - Permit Appliution.doe Revised: 9 -2006 bh Page 2 of 6 Sewer District ..Tukwila ❑ ...Sewer Use Certificate ❑ ...Total Cut ❑ ...Total Fill PUBLIC. WORKS PERMIT INFORMATION. 206 -433 -0179 Scope of Work (please provide detailed information): Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District Tukwila ❑ ...Water District #125 ...Water Availability Provided ❑... ValVue ❑ .. Renton ❑...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which applv): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .- Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ ...Backflow Prevention - Fire Protection " Q:4►pplicuionsWonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Irrigation Domestic Water Call before you Dig: 1- 800 -424 -5555 ,, ❑ .. Highline ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Renton ❑ .. Seattle ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. 2, WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size 1 " 8,1 /4440 UP ❑ ...Sewer Main Extension Public _ Private _ ❑ ...Water Main Extension Public Private _ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter RefundBillingi Name: Mailing Address: City State Zip Day Telephone: City State Zip Page 3 of 6 Unit Type: . Qty Type:" ; : Qty" . Unit Type: Qty Boiler /Compressor:. Qty BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser / 0 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat i 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP/1,750,000 BTU Appliance Vent L Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System ' Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind RIVIIT1FURIVIATII MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ IO 000 Scope of Work (please provide detailed information): J'r..s hal[r.it-l6., o F boa WOIt,k 1`ws i s. 0 $- ; F,a -rit. F4-1- • 3 "Ai 4 • V,riI- /3y Gum town . Use: Residential: New .. -. ❑ Replacement . -.. ❑ Commercial: New Replacement .... ❑ Fuel Type: Electric ❑ Gas...0 Other: Indicate type of mechanical work being installed and the quantity below: Q:\Applications\Fonns- Applications On Linen -2006 - Permit Appliation.doc Revised: 9 -2006 bh City State Zip Page4of6 Fixture Type .. Qty - ' )Fixture Type: °_ ° Qty ` Fixture Type :. ° Qty`. 'Fixture. Type Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets 2 - Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic 1 Floor drain Sinks 1 Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory 2 Water Closet 2 Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent / Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLU11'MBING ;AND GAS PIPING PERMIT INFORMATION - 206-43F-36 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ /f Valuation of Gas Piping work (contractor's bid price): $ 1/000 Scope of Work (please provide detailed information): "r•-• 4.1 11 err rem, I" vNQ trz wi 0 v) 11, ,wd Jain s ash ((444c, e4 0.4%4 ?,a PIV YC.,.S a.yl mho 114 • So Vt. grawwp Trtµ o�.-rl FA•- ►• Building Use (per Int'1 Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: TO 11 iJ ; 1 4 Sewer: TO g /-13 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: Applicatioro\Fotms- Applications On Line \3-2006 - Remit Application :doe Revised: 9 -2006 bh Page 5 of 6 ern)]. tS Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE1pOR AUTHORIZE Signature: Print Name: -A AGENT: Avt.; I (t 5D p .l Mailing Address: 2.3 4 S A-trt. So•L4-(. Date Application Accepted: I 01— Q: Applications Worms-Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bb City Day Telephone: Date: V /N/ Z77 /74 - 71 L{/ ylAS y80zp State Zip Date Application Expires: t� Staff Initials: (.. f.„..- Page 6 of 6 Doc: RECSETS -06 RECEIPT NO: R07 -02441 Initials: JEM User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: WILCOX CONSTRUCTION, INC. SET TRANSACTIONS: Set Member Amount D07 -318 1,409.98 M07 -184 58.00 TOTAL: 1,467.98 ACCOUNT ITEM LIST: Description BUILDING - NONRES MECHANICAL - NONRES STATE BUILDING SURCHARGE SET RECEIPT SET ID: 1107A SET NAME: JAMBA JUICE Payment Date: 11/07/2007 Total Payment: 1,467.98 TRANSACTION LIST: Type Method Description Amount Payment Check 071536 1,467.98 TOTAL: 1,467.98 Account Code Current Pmts 000/322.100 1,405.48 000/322.100 58.00 000/386.904 4.50 TOTAL: 1,467.98 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049081 Permit Number: M07 -184 Address: 17100 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 08/24/2007 Applicant: JAMBA JUICE Issue Date: Receipt No.: R07 -02254 Initials: WER User ID: 1655 Payee: WILCOX CONSTRUCTION TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES Payment Amount: $221.66 Payment Date: 10/15/2007 03:08 PM Balance: $0.00 Amount Payment Check 70964 221.66 Account Code Current Pmts 000/322.100 221.66 Total: $221.66 doc: Receiot -06 Printed: 10 -15 -2007 RECEIPT NO: R07 -01795 Initials: JEM User ID: 1165 Payee: WILCOX CONSTRUCTION, INC. SET ID: S000000834 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http. //www.ci.tukwila.wa.us D07 -318 913.56 M07 -184 47.92 PG07 -219 61.50 TOTAL: 1,022.98 TRANSACTION LIST: Type Method Description Payment Check 070715 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES SET RECEIPT TOTAL: Payment Date: 08/24/2007 Total Payment: 1,022.98 Amount 1,022.98 1,022.98 Account Code Current Pmts 000/345.830 1,022.98 TOTAL: 1,022.98 2027 08/24 5 ' 7 0 TOTAL 1022,98 Project: Type of Inspection: pt.. _ Try -,3A ' Jic Address: f 1t © S. C-V. CI`t-is'� Date Called: Special Instructions: Date Wanted: 1 � 11( 4D7 a • Requester: Phone No: INSPECTION RECORD Retain a copy with permit t-c'01 -f PERMIT NO. CITY OF TUKWILA BUILDING DIVISION , tom. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( 06)431 -3670 INSPECTION NO. Approved per applicable codes. El Corrections required prior to approval. / COMMENTS: Inspector: je a Date: 1 fif $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: 7 /) AM 6 14.-/ (J)),cJN „ wit /e i t ^ i mr -®ti. Address: /7400 co r+ ) � , 0-- , Li - .- favy f /2eicei,,i 1 Special Instructions: Date Wanted:" /,2"-/4/-7 p.m. Requester: Phone �1 : 7 717,47/41/5-__ Project � aGl(h4 VL! /C—P Typ�e section:. .--- /�P / Ova tic ` �f Address: /7400 co r+ ) � Date Called': Special Instructions: Date Wanted:" /,2"-/4/-7 p.m. Requester: Phone �1 : 7 717,47/41/5-__ INSPECTION RECORD Retain a copy with permit INSPECT' NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Cz- 6300 Southcenter Blvd., #100, Tukwila, W t8 (206)431 -3 A pproved per applicable codes. Ins sector 01.01/14,7 f EINSPECTION FEE RE 6300 Southcenter Blvd.. ❑ Corrections required prior to approval. IRED. Pri r to inspection. fee must be s ite 100. ll the schedule reinspection. 'Receipt No.: 'Date: ,//07- /g Proje Typepf Inspect y /!10 Sal /44,4✓h/ (... ;pate Called: Special Instructions: Date Wante r /� Requesterr'': Phone No: ('� 2e6 - Si 7 c7" - 3 X07 /6 e f INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)43 1 -3 7 VL pproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspect • Date: .00 REINSPECTION E REQUIRED. 'rior to inspection, fee must be id at 6300 Southcenter Blvd., Suite O. Call the schedule reinspection. Re eipt No.: (Date: Pro' Type of Inspection: Address: fl t oo S Cm.. w Date Called: Special Instructions: Date Wanted: 12i( oil ,- Requester: Phone No: t ! i INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION x 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 Corrections required prior to approval. COMMENTS: 1/4i( Lo (.1466 - c fie -% 4( w w 0 Approved per applicable codes. Date: v El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be `�� paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: COMMENTS: p, Type rInspection: - % l� ` \. Addres s: `� /i D 6a lied: f 5r',,(' � d �' %� ��o jl i ( ---- J ( 0-.1 ? / -7p- } Proje :, c m b 1 C)7// , Type rInspection: - % l� ` \. Addres s: `� /i D 6a lied: Special Instructions: Date ant d: i 1 / D /(y) a.m. Requester: Phone No: ( e 7 -0314 NSPECTION RECORD Retain a copy with permit I ECTION NO. PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 CITY OF TUKWILA BUILDING DIVISION EJ Approved per applicable codes. El Corrections required prior to approval. eceipt No.: I Date: REINSPECTION FEE QUIRE . Prior to inspection, fee must be at 6300 Southcenter Blv ., Suite 100. Call the schedule reinspection. Projectf Type of Inspection, : v Address: Date Called: Special Instructions: Date Wanted; / / / /"//t ("13 pm Requester: Phone No: INSPECTION RECORD Retain a copy with permit 7 110 7 - / G INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �' _ _ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 Approved per applicable codes. Corrections required prior to approval. COMMENTS: C G _TN 6i/G i eCk1 tL ✓� : 5 ,/ »J e L3, 4 /),445 $58.0 EINSPECTION FEE ' EQUIRED. or n - section, fee must be paid t 6300 Southcenter Blvd., Suite 100. Call the hedule reinspection. 'Receipt No.: !Date: -r, " ...rvt 36 Y0 August 28, 2007 Ralph Milleson 234 5 Ave S Edmonds WA 98020 RE: Letter of Incomplete Application # 1 Development Permit Application M07 -184 Jamba Juice —17100 Southcenter Py, Ste 104 Dear Mr. Milleson: This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 24, 2007 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department needs to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Enclosures File: M07 -184 City of Tukwila Department of Community Development Steve Lancaster, Director P:\Permit Center\lncomplete Letters \2007\1407-184 Incomplete Ltr #1.DOC Jem Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Determination of Completeness Memo Date: August 28, 2007 Project Name: Jamba Juice Permit #: M07 -184 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The 2003 International Building Code and 2004 WA State Energy code are specified on the cover sheet. The City of Tukwila has adopted the 2006 Building and Washington State Energy codes as of July 1 2007. Review construction plans and documents for compliance with 2006 building and energy codes which shall include Washington State code amendments. Make changes to the code specifications shown on the cover page including any other code specifications within the plan set. 2. Provide only those sheets that are relative to the mechanical work. Sheets shall be full size scaled drawings same as original plan set. Should there be questions conceming the above requirements, contact the Building Division at 206-431 -3670. No further comments at this time. ACTIVITY NUMBER: M07 -184 DATE: 10 -31 -07 PROJECT NAME: JAMBA JUICE SITE ADDRESS: 17100 SOUTHCENTER PY, STE 104 Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued DEPARTMENTS. B I ing iv i o Public Works Complete Comments: PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES,THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS R CORRECTIONS: Documents/routing slip.doc 2 -28-02 rtMIvn 1 UUUHI] COPY ❑ Permit Coordinator n DATE: DATE: Planning Division DUE DATE: 11-01-07 Not Applicable ❑ ❑ No further Review Required n DUE DATE: 11-29-07 Approved Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 -184 DATE: 09 -06 -07 PROJECT NAME: JAMBA JUICE SITE ADDRESS: 17100 SOUTHCENTER PY, STE 104 Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Uilkfin>; Division' B Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY - PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DUE DATE: 09-11-07 Not Applicable E No further Review Required DATE: DATE: Planning Division Permit Coordinator n DUE DATE: 10-09-07 Approved ❑ Approved with Conditions 0 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 -184 DATE: 08 -24 -07 PROJECT NAME: JAMBA JUICE SITE ADDRESS: 17100 SOUTHCENTER PY, STE 104 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTIENTS: 00) Bu" iidfng Division MI Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08-28-07 Complete n Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 04214 J LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required n No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents routing slip.doc 2 -28 -02 PERMIT COORD t;UPY PLAN REVIEW /ROUTING SLIP III /- Fire Prevention DATE: DUE DATE: 09-5-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Ti Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Summary of Revision: WANK fjyi M CO ((L 11V At- ROOD Received by: a , . A- lta. . REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: AV VP SITE ADDRESS: i 00 REVISION LOG PERMIT NO: f V W �'r ORIGINAL ISOE DATE: Pi NMI" (please print) (please print) (please print) (please print) (please print) Project Name: Jamba Juice Contact Person: Summary of Revision: City of Tukwila \applications\forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1f X31/'Ze01 FP Response to Incomplete Letter # '&- O Response to Correction Letter # i Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Address: 17100 Southcenter Py, Ste 104 M 1 itt-StAA Plan Check/Permit Number: M07 -184 Gk «A-y s, r,.,... / 14 Va. C J rJ i .i-10 Z ht 19 N t , t-S m bO1 1 !woo?, M It 1 Sheet Number(s): Anita "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: AAA Nata Entered in Permits Plus on 1 ( 3 Steven M Mullet, Mayor Steve Lancaster, Director RECEIVED CITY OF TUKWILA OCT 31 2007 Phone Number: 9 -17 —1 4ISS �vt G- p l 0 l City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www .ci. tukw flaw a. us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 16/7 7 Plan Check/Permit Number: 1%07 - 18 q Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: r'k w%o p J t) G4. Project Address: 11 /DO $ou J c..frt #1. t t i q.•1 t S 1-k, /0 Contact Person: Q,M4t.D 14 t-'-t l (tS D a Phone Number: 4Z-5 - 77 y - 4 S Summary of Revision: � ,..► q ; . t trz L ac 4 S iff to s tA- . Sheet Number(s): eA 001 col- t 10 1 Wt 50 1 "Cloud" or highlight all areas of rev Sion including date /reison Received at the City of Tukwila Permit Center by: Entered in Permits Plus on `1,- S -0-7 lapplications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director tryEP 101 �1�CCIV CITY OF TIJKWIIA SEP. I- a MOT License Information License WILCOC* 194Q0 Licensee Name WILCOX CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 319007592 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 234 5TH AVE SOUTH Address 2 11/21/2005 City EDMONDS County SNOHOMISH State WA Zip 98020 Phone 4257744185 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/20/1981 Expiration Date 12/10/2007 Suspend Date Separation Date Parent Company Previous License WILCOAE376NO Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WILCOX, ROBERT EUGENE PRESIDENT 11/20/1981 LESSARD, MATTHEW J SECRETARY 11/21/2005 LESSARD, JAMES MICHAEL VICE PRESIDENT 11/20/1981 11/21/2005 WILCOX, A E 01/01/1980 01/01/1980 WILCOX, LAURA 01/01/1980 01/01/1980 OLDS, HOWARD A SECRETARY 01/01/1980 01/01/1980 LVVR Vi) a VV11L16GLV1, L'1GGL11G• ^ll Vl 1 1L11111)G1 L iG4.11JG LGLCL11 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. 1 ae.s l Vl J ti.4M / /enrfrono ur. rrnrr /l n ;/Ma ;n /rwrinfPr env 9T ;..P„cs =WTT r *1 Qann 1 11 /1 / ')nm DIVISION 15 - MECHANICAL SECTION 15000 BASIC MECHANICAL REQUIREMENTS A. NOTE 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR I5 RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WITH JAMBA JUICE'S SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS WORK. 5. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT THE BID. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR JAMBA JUICE SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND JAMBA JUICE'S PROJECT MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH I5 USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 7. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY JAMBA JUICE'S PROJECT MANAGER AND THE LANDLORD. ALL PATCHING SHALL BE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES. 8. THE MECHANICAL CONTRACTOR SHALL MAKE ALL FINAL MECHANICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. a. THE MECHANICAL CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR TO CONTACT THE HVAC EQUIPMENT MANUFACTURER'S REP. FOR START UP. C. (PARAGRAPH OMITTED) D. CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS AWARDED, CHANGE ORDERS FOR INCREASED COSTS DUE TO CODE ISSUES WILL NOT BE ACCEPTED BY JAMBA JUICE. E. LICENSES. PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. FURNISH TO JAMBA JUICE'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. F. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY JAMBA JUICE'S PROJECT MANAGER THROUGH SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE PRIOR TO INSTALLATION. THE USE OF ANY UNATHORIZED EQUIPMENT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO JAMBA JUICE'S PROJECT MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR JAMBA JUICE'S PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP AND /OR THE SIGNATURE OF THE GENERAL CONTRACTOR AND THE SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. G. GUARANTEE 1. THE EQUIPMENT MANUFACTURER SHALL GUARANTEE AND PROVIDE A 12 MONTH GUARANTEE TO JAMBA JUICE FROM THE DATE OF ACCEPTANCE. THIS CONTRACTOR SHALL WARRANTY THE INSTALLATION OF THIS EQUIPMENT AND WILL BE RESPONSIBLE FOR ANY DAMAGE AND /OR MALFUNCTION CAUSED BY THE INSTALLATION. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. H. K. L. M. N. RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE SET OF DRAWINGS ON THE JOB SITE UPDATED WEEKLY TO RECORD ALL DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: a. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. b. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. c. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TO KEEP THESE RECORDS WILL ALLOW JAMBA JUICE TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE THESE RECORDS AT HIS EXPENSE PRIOR TO FINAL PAYMENT. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR 15 RESPONSIBLE TO ADVISE JAMBA JUICE'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, JAMBA JUICE'S PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. PHASING REQUIREMENTS 1. THIS CONTRACTOR I5 TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S HVAC, PLUMBING AND SPRINKLER SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE IN WRITING WITH JAMBA JUICE'S PROJECT MANAGER AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE HVAC, PLUMBING OR FIRE PROTECTION SYSTEMS. DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING HVAC UNITS, HYDRONIC PIPING, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL / FLOOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED. FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, JAMBA JUICE SHALL HAVE AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. END OF SECTION 15000 FILE COPY Permit No. Pier review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Fie04 Copy and is ad01lowledged: g +, Date: 1 City of Tukwila BUILDING DIVISION 4 5 I SEPAR ETA PERM REQUIRED FOR: I CI echanical Eg Electrical O Plumbing O Gas Piping City of Tukwila BUILDINI DIVISION SPECIFICATIONS SECTION 15500 HEATING, VENTILATION AND AIR CONDITIONING A. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE HVAC SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: B. C. D. a. c. d. g- 6 7 HVAC UNITS, ALL RELATED EQUIPMENT AND ACCESSORIES (UNLESS NOTED OTHERWISE). b. DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. HYDRONIC PIPING. (AS APPLICABLE, REFER TO PLANS). REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS). e. CURBS, ROOFING, AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). f. TESTING, ADJUSTING, AND BALANCING. KEEPING A RECORD SET AND PREPARE AS -BUILT DRAWINGS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOBSITE AND EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES TO MEET STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. HVAC EQUIPMENT 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED PER THE RESPONSIBILITY SCHEDULE, UNLESS NOTED OTHERWISE_ REFER TO PLANS FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 4. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO CAPTURE POTENTIAL LEAKS FROM THE ENTIRE UNIT. PROVIDE CONDENSATE PUMPS AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. (PARAGRAPH OMITTED) METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO JOB SITE VISIT AND APPROVAL BY THE GENERAL CONTRACTOR. A SKETCH MUST BE SUBMITTED INDICATING DEVIATIONS FROM DESIGN AND MUST BE APPROVED BY JAMBA JUICE'S PROJECT MANAGER PRIOR TO FABRICATION OR INSTALLATION. 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. WHERE OTHER CODES ARE ENFORCED, (IE. UMC, BOCA, ETC.) USE THE MOST STRINGENT CODE FOR DUCT CONSTRUCTION STANDARDS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: 2" W.G., POSITIVE RETURN AND EXHAUST DUCTS: 2" W.G., NEGATIVE EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: CLASS B - 3" W.G. RETURN AND EXHAUST DUCTS: CLASS C - 2" W.G. IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. 4. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCKSEAM CONSTRUCTION FOR ALL SIZES 14" DIAMETER AND LARGER. ROUND DUCTWORK SIZES 13" DIAMETER AND SMALLER MAY BE SNAP -LOCK CONSTRUCTION. ALL SNAP -LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL WITH SPOT WELDED AND BONDED CONSTRUCTION. 5. ROUND SPIRAL GALVANIZED STEEL DUCTWORK MAY BE USED IN PLACE OF RECTANGULAR DUCTWORK IN HORIZONTAL APPLICATION WHEN ABOVE CEILING CLEARANCES PERMITS AND EQUIVALENT FREE AREA IS MAINTAINED, WITH THE FOLLOWING EXCEPTION; ALL SUPPLY AND RETURN DUCTWORK WITHIN 15 FEET OF THE AIR HANDLER MUST BE RECTANGULAR AND INTERNALLY LINED. ONCE A TRANSITION IN THE DIRECTION OF THE AIRFLOW TO SPIRAL HAS BEEN DONE, DUCT WILL NOT BE ALLOWED TO REVERT TO RECTANGULAR. WHERE ROUND DUCT SUBSTITUTION WILL TAKE PLACE, SUBMIT A SKETCH AND CHART SHOWING EQUIVALENT ROUND CONVERSIONS OF RECTANGULAR DUCTWORK TO JAMBA JUICE'S PROJECT MANAGER FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION. 6. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS IN MAIN DUCT PER LATEST EDITION OF SMACNA. 7. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE A MINIMUM 1 -1/2" x 1 -1/2" x 1/8" STEEL ANGLE FRAME AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. g- ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASSFIBER - FABRIC REINFORCED TAPE. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. 10. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 11. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. D. METAL DUCTWORK (CONTINUED) 12. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY JAMBA JUICE'S PROJECT MANAGER PRIOR TO INSTALLATION. IN HARD CEILINGS, LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WHEN WITHIN 3' -0" OF DEVICE. 13. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. VAV BOX, DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. • ■ : -■ ,' • ■ i• WH CONSTRU OF 4 INC ALL GAUGES AND REINFORCE STANDARDS FOR MEDIUM PRESSURE ND 2. 3. EDIUM PRESSURE DUCT WITH "LO -LOSS" UCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT C ACCORDANCE WITH SMACNA STANDARDS FOR INCHES WA LUMN MINIMUM OR GREATER AS CONNECTIONS TO THE LA MUST MEE 'S MEDIUM PRES TEE TAPS OR AS OTHERWISE R 10 5 A I:E SSURE RATING ED BY LANDLORD. THE LATEST EDITION OF SMACNA WITH THE LANDLORD'S CRITERIA. DUCTWORK SHALL BE MADE D BY THE LANDLORD 4. ALL 0 - EMS FROM METAL DUCTWORK SPECIFICATION SECTION I TO THIS ON, WITH THE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK M WRAPPED INSULATION, NOT LINED. F. VIBRATION ISOLATION DEVICES 1. SPRING VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND STRUCTURE. ISOLATORS TO BE SIZED ACCORDING TO LOAD WITH A MIN. 1" DEFLECTION. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 2. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. 3. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 4. CONSULT MANUFACTURER FOR APPLICATION DATA. G. FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE- COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. H. FLEXIBLE AIR DUCT 1. FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1, UL LISTED AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS ON THE DRAWINGS. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS. 3 . FLEXIBLE DUCT SHALL NOT EXTEND OVER 5-0" IN LENGTH AT ANY ONE LOCATION. SUPPLY AIR TAKE -OFF FITTINGS 1. FURNISH AND INSTALL CONICAL, TAPERED OR 45 DEGREE SADDLE TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALLATION SHALL BE PER SMACNA LATEST EDITION. K. DAMPERS 1. WHERE DESIGNATED, FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. DURODYNE MODEL NO: K SERIES QUADRANT. 2- OPERATING HANDLES ON ALL DAMPERS SHALL BE TAGGED WITH A MINIMUM 18" LONG ORANGE MARKER TAPE. 3. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, A REMOTE DEVICE, MANUALLY OPERATED SHALL BE USED. UNITS SHALL BE ORDERED THREE WEEKS BEFORE INSTALLATION TO ALLOW FOR DELIVERY LEAD TIME. FIRE /FIRE SMOKE DAMPERS 1. FURNISH AND INSTALL PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED AND MEET ALL CODE REQUIREMENTS. 2. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 DEGREE F FUSIBLE LINK, TYPE B, AS MINIMUM. FURNISH AND INSTALL ACCESS DOORS AS NECESSARY. 3. FURNISH AND INSTALL ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND CODE REQUIREMENTS. 4. FIRE SMOKE DAMPERS SHALL BE FURNISHED AND INSTALLED WITH ELECTRIC POWERED MECHANISM. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER REQUIREMENTS. DUCTWORK INSULATION FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. ALL SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK SHALL BE INTERNALLY INSULATED WITH 1" THICK, 1 -1/2 LB. DENSITY LINE (C =0.28 © 75 DEGREE F). WHEN A COMPLETE DUCTED RETURN AIR SYSTEM IS INDICATED ON THE DRAWINGS, ONLY THE 15' -0" OF THE RETURN AIR DUCT CLOSEST TO THE AIR HANDLING UNIT I5 TO BE INSULATED. LINER 15 TO HAVE A COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES TO BE COATED WITH ADHESIVE. 3. DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1 1/2" THICK, 1# DENSITY (R =5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM, EXCEPT LINED DUCTWORK SPECIFIED ELSEWHERE AND EXHAUST DUCTWORK. ALL JOINTS MUST BE OVERLAPPED AND TUCKED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND OTHER PENETRATIONS. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. 1. dp DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817 -251 -8411 Issue Date Drawn By Appv'd By Revisions Date A A A 0 A J5.2.2 VERSION W ce Y a o_ co co co d) • z 2 < W NV , f) 0 ° O M -001 8/21 /07 J LP DAR Description ro 0 0 a 0 - 0 O By (.;I I Y Ur 1 ur`v no-r Q 1 'inn- V1J l J r ■•rV\IT RECEIVED ,„,,, A I Y rtr11v11 1 _I'- v o EC ID 05-10-07 5.2.2 Mechanical Specs. 0 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. RVS1ONN MOI-Hs SPECIFICATIONS (CONTINUED) CONSTRUCTION NOTES GENERAL NOTES CONTINUED FROM SHEET M -001 . REFRIGERANT PIPING (CONTINUED): - 5 STARTING SEALS SHALL OPEN CONSTRUCTION. PSIG. SYSTEM OF R -22 CASE L REF' B . : INSPEC AS NECESSA` THICK AND INDUSTRY HOT SUBMIT OF INSPECTION PROPER BE A AND RETURN, REFRIGERANT AND INSTALL DESCRIBED WITH LOCAL 50 CURBS IN EXPENSE. WRITTEN RESPONSIBLE BY LIFT TRAPS AND /OR DOUBLE SUC ON OF FIELD CONDITIONS AND EQUIP )' T AT THE INDOOR U AND WORKING ON THE OUTDOOR U SHALL BE BE USED DURING A LL BRAZING AND ANY LINES SHALL BE APPED AND SEALED P SSURE TEST FOR LEAKS REDO LEAKI■ JOINTS AND RETEST UNTIL TO 00 MICRONS OF MERCURY. AND INERT GAS TO 245 PSI AND 'ATERS 24 HOURS PRIOR TO STARTING ERANT LIQUID IS OUT OF THE 8' ORE THE REFRIGERANT PIPING INSULATION . D BY A REPRESENTATIVE OF THE LINES ANA CONDENSATE LINES WITH • PIPE INSU • TION WITH FLAME SPREAD A SMOKE DEVE 1•ED RATING OF NOT MORE STANDARDS. 00 NOT INSULATE THE GAS BYPASS. A COMPLETE PIPING SC ATIC TO THE FOR APPROVAL PRIOR TO B ■ NING PIPING, THIS CONTRACTOR MUST C L THE OF WORK PERFORMED. ALL MS PERFORMANCE BY MANUFACTURER THIS INSPECTION IS PERFORMED AT JAM: • MARKERS ON ALL PIPES INSTALLED UNDER MINIMUM OF 1 -1/2" X 8" AND IDENTIFIED IN LETTER COLORS ISSUED BY THE AMERICAN CHILLED WATER RETURN, CHILLED WATER HOT WATER SUPPLY, CONDENSER WATER LIQUID, REFRIGERANT SUCTION, MUST BE VISIBLE AT EQUIPMENT. ALL NECESSARY CURBS REQUIRED TO ON THE DRAWINGS. CURBS SHALL BE A AREA REQUIREMENTS) HIGH, OF THE UNLESS NOTED OTHERWISE. ALL CURBS ARE LEVEL. ALL PENETRATIONS OF ACCORDANCE TO THE LANDLORD'S THIS CONTRACTOR MUST RECEIVE APPROVAL BEFORE ANY WORK TAKES FOR ALL SEISMIC, HURRICANE OR , LOCAL OR OTHER CODES ALL WORK SHALL BE MADE BY AN LICENSED ASSOCIATED AIR ENVIRONMENTAL BALANCING BUREAU BALANCE REPORTS WILL BE ACCEPTED. AND DONE NE IN ACCORDANCE WITH THE PAYMENT OF ALL COSTS FOR TESTING THE BID. HOWEVER, IT WILL BE THE G.C. AIR BALANCING COMPANY. SCHEDULE PROVIDE A COPY OF THE OUTSIDE AIR REPORT TO OWNER REPORT MUST BE COMPLETE AND TO JAMBA JUICE 1 WEEK PRIOR TO FOR AIR BALANCE TO VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW AIR BALANCE. THE COMPLETE AIR AIR DAMPERS IN MINIMUM POSITION, SHALL ALSO INSTALL A NEW SET (INTERLOCKED EQUIPMENT, SMOKE ETC.) AND OPERATING STATUS OVERRIDE OF MINIMUM OUTSIDE AIR FOR CO2 MONITORING CONTACT, SEE SHALL BE SUBMITTED THROUGH THE FOR APPROVAL. THE GENERAL CONTRACTOR REPORTS PRIOR TO SUBMITTING TO JAMBA AIR BALANCE REPORT TO MALL ALL APPLICABLE TESTING AND SYSTEM DESIGNED ON THESE DRAWINGS. BALANCED AT THE TIME OF ORIGINAL AT NO ADDITIONAL EXPENSE TO JAMBA RECHECK ANY ITEMS THAT JAMBA JUICE TO JAMBA JUICE. REFER TO OWNER'S SPECIFICATIONS FOR MORE INFORMATION OTHER TRADES. 1. IT IS REQUIRED THAT THE MECHANICAL CONTRACTOR FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS LOCATIONS AND ELECTRICAL RUNS. ADDITIONALLY, VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH DUCTWORK, ETC., PRIOR TO SUBMITTING HIS BID. NO BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S AND /OR PRE - DETERMINE ALL EXISTING CONDITIONS DISCREPANCIES SHALL BE IMMEDIATELY REPORTED REPRESENTATIVE FOR RESOLUTION 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL CODES AND LANDLORD'S REQUIREMENTS. 3. UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL MATERIALS, LABOR AND SUPERVISION NECESSARY VENTILATING AND AIR CONDITIONING WORK WHICH INCLUDES, THE FOLLOWING: a° FURNISH AND INSTALL 4 "95, 24GA. GALVANIZED (FIELD VERIFY EXACT SIZE AND LOCATION, MINIMUM b. REMOVE ALL EXISTING DUCTWORK AND EQUIPMENT DISPOSE OF SAME OFF LANDLORD'S PREMISES. C. FURNISH AND INSTALL ALL NEW DUCTWORK INCLUDING DAMPERS IN ACCORDANCE WITH S.M.A.C.N.A. CURRENT LANDLORD'S REQUIREMENTS - (SHOWN ON PLANS 1. ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL UNDERWRITER'S AND UNION LABELS WHERE 2. ALL DUCTWORK SHALL BE FABRICATED FROM PRE - INSULATED ALUMINUM CORRUGATED FLEXIBLE THE STANDARD OF AMERICAN SOCIETY, REFRIGERATION ENGINEERS NATIONAL ASSOCIATION, FOR LOW DUCTWORK OR AS PER LOCAL CODE. 3. BRANCHES FROM MAIN LOW VELOCITY TRUNK WITH SPLITTERS, DAMPERS OR SIMILAR BALANCING WITH THE STANDARDS OF THE ASSOCIATED DAMPERS SHOULD BE PROVIDED AS REQUIRED AND /OR JURISDICTIONAL AUTHORITIES). 4. ALL DUCTS FOR FINAL CONNECTION TO DIFFUSER LISTED (SL 181) FLEXIBLE AIR DUCT NOT TO (THERMAFLEX, , GLASSFLEX OR APPROVED EQUAL). 5. SUPPLY DUCTWORK SHALL BE INSULATED WITH BLANKET INSULATION WITH VAPOR BARRIER. PROVIDED AS REQUIRED PER NFPA STANDARDS, RATED. (EQUAL TO MANVILLE FIBERGLASS INSULATION) 4 ALL COMPONENTS AND EQUIPMENT SHALL BE PROVIDED AND MAINTENANCE AS REQUIRED BY CODE AND THE 5. FURNISH AND INSTALL THERMOSTAT AS SHOWN ON MAX. OF 4FT A.F.F. (VERIFY LOCAL CODES). COORDINATE OWNER'S REPRESENTATIVE. PROVIDE CONTROL WIRING 6. CONTRACTOR SHALL PROVIDE PRODUCT DATA SUBMITTALS DEVICES TO THE OWNER FOR HIS REVIEW AND/OR PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. T ESTING, 7• LANDLORD SHALL PROVIDE A/C UNIT FILTER REPLACEMENT COMPLETE. 8. INSTALLATION ACCEPTANCE MAY BE SUBJECT TO CONSTRUCTION INDEPENDENT AIR CONDITIONING FIRM. 9. UPON COMPLETION ETI N OF THE WORK, THE CONTRACTOR BALANCE THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS PROPER WORKING ORDER. ADJUST AIR QUANTITIES SUBMIT A COPY OF AIR BALANCE REPORT BY AN TECHNICIAN, CERTIFIED BY THE AABC (ASSOCIATED (NATIONAL ENVIRONMENTAL BALANCING BUREAU), SET OF THE "AS- BUILT" DRAWINGS TO THE OWNER RECORDS AND TO THE DESIGN ENGINEER'S OFFICE NOTE: SMOKE DETECTORS INSTALLED WITHIN AIR MOVING TO THE SATISFACTION OF THE LOCAL FIRE DEPARTMENT. THE REQUIREMENTS OF THE LOCAL FIRE DEPARTMENT. AND COORDINATION WITH MUST VISIT THE JOBSITE TO STRUCTURAL ELEMENTS, PLUMBING MECHANICAL CONTRACTOR SHALL ITEMS AS H.V.A.C. UNITS, ADDITIONAL COMPENSATION WILL FAILURE TO VISIT THE JOBSITE BEFORE SUBMITTING HIS BID. ANY TO THE OWNER'S FIELD ALL APPLICABLE GOVERNMENT AN PROVIDE ALL EQUIPMENT, TO COMPLETE THE HEATING, BUT 15 NOT LIMITED TO STEEL EXHAUST DUCT FROM DRYER OF 4 "). NOT TO BE RE -USED AND GRILLES, DIFFUSERS AND STANDARDS AND THE AS SOLID LINES). GRADE, AND BEAR SUCH LABELING APPLIES GALVANIZED SHEET METAL OR DUCT IN ACCORDANCE WITH AND AIR CONDITIONING PRESSURE, LOW VELOCITY DUCTWORK SHALL BE FURNISHED DEVICES IN ACCORDANCE AIR BALANCING COUNCIL. (FIRE BY ANY APPLICABLE CODES SHALL BE CLASS 1 U.L. EXCEED 5' -0" IN LENGTH ONE (1) INCH THICK MINIMUM ACOUSTICAL LINER MAY BE I.R.I. REQUIREMENT AND U WITH AN EASE OF SERVICE LANDLORD. THE PLAN AT A MIN. OF 3FT - EXACT LOCATION WITH AND CONTROLS AS REQUIRED. FOR ALL EQUIPMENT AND e 1. 2. 3. 4. 5. 6. 7. 8. 9. 1D. 11. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT MECHANICAL PLAN CHECK DIVISION AND THAT DIVISION'S STAMP APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. COORDINATE ALL WORK WITH ARCHITECTURAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. 15 TO BE IN CONTACT WITH ANY EQUIPMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION_ REFER TO THE MECHANICAL SHEETS FOR DETAILS, SCHEDULES AND SPECIFICATIONS. CONTRACTOR SHALL PROVIDE CUT SHEETS TO JAMBA JUICE FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. HVAC CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY SMOKE EVACUATION SYSTEM IN USE AT THE MALL AT THE TIME OF THE BID. IF THE SAID SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE MECHANICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO A LANDLORD'S SMOKE EVACUATION SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE ITEM FOR THE SMOKE EVACUATION SYSTEM AT THE TIME OF THE BID. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE /MAINTENANCE EASE. PRIOR TO STARTUP OF HVAC EQUIPMENT, MECHANICAL CONTRACTOR WILL CONFIRM WITH HVAC MANUFACTURER THAT BEEN TURNED ON 15 MINIMUM OF 24 S. JAMBA PROVIDED HVAC UNITS AND HAS BEEN TURNED ON A MINIMUM OF 24 HOURS. JAMBA JUICE RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD JAMBA JUICE FIND CORRECTIVE WORK TO BE NECESSARY, THEY WILL NOTIFY CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE CONTRACTOR. IF WORK IS REQUIRED BY JAMBA JUICE IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY JAMBA JUICE TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE CONTRACTOR CANNOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE THE OWNER MAY, AT HIS DISCRETION TAKE OVER SUCH WORK AND BACKCHARGE THE CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND /OR ADHERENCE TO PLANS AND SPECIFICATIONS. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. SECTION 15500 INSTALLATION a• UCTION LINES SHALL HAVE ADEQUATE ' • RS TO MEET THE REQUIREMENTS MA . ACTURER'S RECOMMENDATIONS. • b. BRAZE • . JOINTS WITH SILFOS TOWARD T . OUTDOOR UNIT. THE BROKEN LAS . • NITROGEN BLEED TIME THE SYST IS OPEN. ALL BEFORE LEAVING • SITE DURING WITH AN INERT GAS ►• TO 245 SYSTEM IS TIGHT. EVAC TE ENTIRE CHARGE SYSTEM WITH 25 �' RETEST SYSTEM. ENERGIZE '•NK COMPRESSOR TO ENSURE THAT COMPRESSOR. c. UPON COMPLETION OF TESTING, IS APPLIED, THE PIPING MUST LOCAL GOVERNING AUTHORIT d_ INSULATE THE REFRIGER • IT SUCTION RUBATEX OR ARMSTRP'+G 1 INCH RATING OF NOT MO THAN 25 THAN 50 IN AC P."'DANCE WITH HOT GAS (LI• . •) LINES OR ANY 4. INSPECTION 0. CONT' ACTOR MUST PREPARE AND LOP AL MANUFACTURER REPRESENTATIVE +STALLATION. UPON COMPLETION LOCAL REPRESENTATIVE FOR FIELD FOUND TO BE INADEQUATE FOR REPRESENTATIVE MUST BE CORRECTED. JUICE'S EXPENSE. 0. LABELS /PIPE MARKERS CONTINUED HEATING, VENTILATION AND AIR CONDITIONING M. HYDRONIC PIPING 1. FURNISH AND INSTALL A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC SYSTEM IS REQUIRED. 2. PIPING a. HYDRONIC PIPING FOR CHILLED WATER, CONDENSER WATER AND /OR HEATING WATER SHALL BE ASTM A -53, SCHEDULE 40, ERW, BLACK STEEL PIPE WITH P AIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2 INCH AND LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS. INSTALL TYPE "K" COPPER PIPE FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNI INS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT GONFORMAN E WITH •STM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER IS MOST STRING NT. 1 NIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHER SERVICE 0 REMOVAL MAY BE REQUIRED. b. AL. PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LE • AGE AT A MIN UM PRESSURE OF 125 PSI. c. ALL YDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PI' NG SYSTEM SHAL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE .TRAINER SCREE S. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND •UIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SY EM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FR' M THE LANDLOR 'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO 4 .0 FROM THE LANDLORD . FIELD REPRESENTATIVE. ANY RUNS THRU A CHAS OR SHAFT WILL BE DONE WITH FEWEST JOINTS POSSIBLE USING THE LONGEST LEN TH OF HARD PIP. AVAILABLE. SHOULD A JOINT BE REQUIRED, CO RACTOR SHALL MAKE ALL E ORTS TO KEEP THE JOINTS IN ACCESSIBLE AR ► AS. d. PRIOR TO CO ECTION TO THE LANDLORD'S SYSTEM, CONTACTOR SHALL OBTAIN WRITTEN CONFI "MATION FROM THE LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHI 0, AND PROPER FILLING OF THE TENAN S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUI'EMENTS AND THAT THE TENANT'S SYSTEM IS READY TO BE CONNECTED TO TH LANDLORD'S SYSTEM. 3. VALVES a. GATE VALVES, 2 - IN AND SMALLER: CLASS 150, B �DY AND UNION BONNET OF ASTM B 62 CAST BIR NZE WITH THREADED OR SOLI R ENDS, INTEGRAL SEAT, RENEWABLE SOLID BR• ZE WEDGE DISC, RISING ST:' , SCREWED BONNET AND RE PACKABLE UNDER "RESSURE. BALL VALVES •' E ACCEPTED AS AN EQUAL SUBSTITUTION. b. GATE VALVES, 2 - 1/2 IN AND LARGER: CLAS' 125 CAST IRON BODY, RENEWABLE BRONZE SEAT AND SOLID WEDGE DISC, RISING STEM, FLANGED ENDS, AND RE PACKABLE UNDER PRESSURE. c. SWING CHECK VALVES, 2 - INS H AND SMALLE CLASS 150. CAST BRONZE BODY AND CAP CONFORMING TO ATM • B 62 WITH ORIZONTAL SWING, Y PATTERN, RENEWABLE BRONZE DISC, ANO HAVING TH ADED OR SOLDERED ENDS. d. SWING CHECK VALVE, 2 IN H AND L "RGER: CLASS 125 CAST IRON BODY AND BOLTED CAP, HORIZONTAL SWIN RENEW BLE BRONZE DISC, FLANGED ENDS AND CAPABLE OF BEING REFITTED WHIG E THE VALVE REMAINS IN THE LINE. e. COMBINATION BALANCING AND SH - O' F VALVES: BELL & GOSSETT CIRCUIT SETTER WITH LOCKING SET POINT. • • RCUIT SETTER BALANCE WHEEL MUST BE INCLUDED WITH 0 & M MANUAL. TAR') OR GRISWOLD ARE CONSIDERED AS EQUAL. 4. PIPING SPECIALTIES a PRESSURE /TEMPERATURE TEST PL -GS PETE'S PLUG) - 1/4 INCH NPT FITTINGS TO RECEIVE EITHER A TEMPERAT 'E OR PRESSURE PROBE, 1/8 INCH O.D. FITTING AND CAPS SHALL BE BRASS WIT VALV CORE OF NORDEL, RATED AT 400 PSIG, 0 TO 200 DEGREES F. b. STRAINERS - "Y" PATTERN STRAINERS, 12 PSIG, CAST IRON BODY WITH PERFORATED STAINLESS STEE SCREEN, TH' ADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2 INCHE AND LARGER. •CREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INC FOR CHILLED OR CONDENSER WATER. PROVIDE WITH . SLOWDOWN VALVE WITH H E END FITTING. 5. INSULATION a. ALL HYDRONIC PIPING FAR CHILLED WATER AND/OR HEATING WATER NOT / (NOT INCLUDING CONDENSER ATER UNLESS SPECIFICAL► Y NOTED OTHERWISE), VALVES, FITTINGS, AND ACCES ARIES SHALL BE INSULATED. FOR PIPE SIZES UP TO 2 INCHES, INSULATE WI r 1 INCH THICK (K =0.23 ©7' °F) FIBERGLASS INSULATION WITH ALL SERVICE JI CKET AND VAPOR BARRIER. FO' PIPE SIZES 2 - 1/2 INCHES AND LARGER, INSU • TE WITH 1-1/2 INCH THICK (K =• 23 @ 75 °F) FIBERGLASS INSULATION WITH • L SERVICE JACKET AND VAPOR BARRIER. b. INSULATION AT A L HANGERS FOR PIPING 2 1 2 INCHE AND LARGER SHALL BE HARD AND NO COMPRESSIBLE. c. ALL INSULATIO SHALL HAVE A FLAME SPREAD RATING 0 NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 5 TO CONFORM WITH THE REQUIRE ENTS OF THE NFPA. d. PROVIDE ZE•. ON OR EQUAL INSULATION FITTINGS FOR ALL T S, ELLS OR SPECIALTY ITTINGS. 6. GENERAL INS ALLATION a. INSTALL ' ATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCIN• COUPLINGS AT CHANGE. IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. b. BRANC ES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM 0 MAINS AT A 45 D PEE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES T UNITS ABOVE MAIN'. TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE •ITCHED UP ARD TOWARDS UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. c. SE' MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. N. REFRIG ANT PIPING: 1. FURNISH AND INSTALL PIPE IDENTIFICATION THIS CONTRACT. MARKERS SHALL ACCORDANCE WITH THE BACKGROUND NATIONAL STANDARDS INSTITUTE 2. PIPING SHALL BE IDENTIFIED SUPPLY, CONDENSATE, HOT RETURN, CONDENSER WATER AND DIRECTIONAL ARROWS. ALL P. CURBS FOR SUPPORT (ANSI) AS FOLLOWS: WATER SUPPLY, IDENTIFICATIONS AS EQUIPMENT OF BE DONE ALSO 1. THIS CONTRACTOR WILL FURNISH INSTALL ALL HVAC EQUIPMENT MINIMUM OF 14" (SHALL COMPLY SAME MANUFACTURER OF THE MUST BE INSTALLED THAT TOP EXISTING STRUCTURE SHALL GUIDELINES AT THIS CONTRACTOR'S JAMBA JUICE'S PROJECT MANAGER'S PLACE. THIS CONTRACTOR 15 . OTHER SECURING DEVICES REQUIRED Q. ADJUSTING, AND BALANCING APPROVAL PRIOR TO THE AFTER CONSTRUCTION 15 REVIEW BY AN - SHALL TEST, START UP AND AS REQUIRED TO INSURE TO WITHIN 1O% OF DESIGN VALUES. OUTSIDE CERTIFIED AIR BALANCE AIR BALANCE COUNCIL) OR NEBB AND A COPY OF REPRODUCIBLE AND TO THE LANDLORD FOR THE PRECEDENT TO FINAL PAYMENT. SYSTEMS SHALL BE FULLY TESTED TESTING SHALL CONFORM. TO 4 °r� \' _ ' HVAC LOAD CALCULATION 1 TESTING, ADJUSTING INDEPENDENT CONTRACTOR BALANCING COUNCIL NEBB BALANCING ( ) ALL BALANCING MOST RECENT STANDARDS AND BALANCING THAT WILL CONTRACT BALANCING WITH CERTIFIED AIR BALANCE PRIOR TO OCCUPANCY. 2. FINAL TESTING, ADJUSTING WITH MERCHANDISING DATE. 3. THE HVAC CONTRACTOR ACCESSIBILITY TO FILTERS IN ALL UNITS BALANCE SHALL EXCEPT AS NOTED OF FILTERS ONE 4. ALL CONTROL SEQUENCES DETECTORS, SMOKE RECORDED IN THE 5. AIR BALANCING CONTRACTOR INTAKE UPON CO2 AIR BALANCE COVER 6. THREE COPIES OF GENERAL CONTRACTOR SHALL VERIFY THE JUICE. SUBMIT ONE GENERAL MANAGER. 7. THE BALANCING BALANCING FUNCTIONS ALL SYSTEMS UNABLE BALANCE MUST BE JUICE. THE BALANCING DEEMS NECESSARY END OF SECTION 15500 AND BALANCING OF WHO 15 A CURRENTLY (AABC) OR NATIONAL CONTRACTOR. ND OTHER WORK MUST BE COMPLETE OF THEIR SOCIETY. SHALL BE INCLUDED IN DIRECTLY WITH THE OWNER'S FIELD REPRESENTATIVE. REPORT AND CERTIFIED AND BALANCING FINAL CLOSE -OUT DOCUMENTS SHALL BE PRESENT ALL DEVICES, VERIFY JUST PRIOR TO THE TAKE PLACE WITH OUTSIDE OTHERWISE. HVAC CONTRACTOR DAY PRIOR TO MERCHANDISING. SHALL BE TESTED EVACUATION, ECONOMIZER, BALANCE REPORT. I5 TO CONFIRM MONITORING CONFIRMATION. SHEET E00.0. THE BALANCE REPORT TO JAMBA JUICE COMPLETENESS OF THE COPY OF FINAL APPROVED CONTRACTOR SHALL PERFORM REQUIRED FOR THE TO BE COMPLETELY BALANCED IN FUTURE CONTRACTOR SHALL AT NO ADDITIONAL COST D ESIGN CONDITIONS: OUTDOOR INDOOR DIFFERENCE SUMMER DRY BULB 85 75 10 SUMMER WET BULB 68 62.5 5.5 HUMIDITY RATIO 76 65 11 WINTER DRY BULB 22 70 4B SUMMER DESIGN MONTH: JUNE DAILY SWING 19 DATE 9/7/2007JOB # 070288 CLIENT JAMBA JUICE ADDRESS SOUTHCENTER SQUARE CITY & STATE TUKWILA, WA ASHRAE CITY SEATTLE CO ALTITUDE 14 LATITUDE 47 LEASE AREA 1508 SQ. FT. C ITEM DIR, CLTD LAT CORR K IAT ODA 0 CORK TEMP CORR N ROOF FLAT 78 2 1 3 -9.5 D WALL NORTH 10 1 1 3 -9.5 U WALL SOUTH 17 3 1 3 -9.5 C WALL EAST 29 2 1 3 -9.5 T WALL WEST 14 2 1 3 -9.5 GLASS ALL 14 2 1 3 -9.5 ITEM DIR, SC SHGF CLF AREA S O GLASS NORTH 0.39 46 0.82 0 GLASS SOUTH 0,39 105 0.64 90 0 R GLASS WEST 0,39 215 0 76 290 L TYPE WATTS X BTU /X FAC I G FLUORESCENTS 1204 3.41 1.1 H FLUORESCENTS 169 3,41 1. 1 T INCANDESCENTS 700 3.41 1 S INCANDESCENTS 550 3, 41 1 E ITEM VALUE X MULTI = U EQUIP. @.5W /SF 0 0.5 3.41 0 I HVAC FAN HP 1.5 1 2545 3818 P EQUIPMENT 18000 0.25 3.41 15345 PEOPLE 100 SQ. FT. /PERSON 250 0 AREA X CFM /SF X BF X TEMP DIFF A 1508 0.19 0.1 10 1508 0.19 1.0 48 COMBINED DUCT LOSS, INFILTRATION, WARM -UP AND SAFETY MARGIN CORR U AREA BTUH BTUH CLTD VAL COOLING HEATING 74 0.05 1508 5542 x619 5 0.05 0 0 0 14 0.05 70 47 168 25 0.05 0 0 0 10 0.05 5 2 12 10 0.80 380 2888 14592 SUBTOTALS 8480 18391 NOTES 0 5' -0' AWNING 2359 5' -O' AWNING 14183 X % TO SPACE 0.75 RECESS 3387 1.00 SURF 634 1.00 SURF 2387 0. 75 RECESS 1407 BOR ASHRAE BTUH 0 3818 15345 BTUH /PERSON 3770 X FACTOR 1.10 319 1. 10 15305 @ 5% 2804 ` v ,A� SYM _-� OL � . SYMBOL - DESCRIPTION ° Q THERMOSTAT D REMOTE SENSOR , SUPPLY DIFFUSER , RETURN GRILLE L ROOM SENSIBLE HEAT GAIN (LOSS) = 61170 33696 T OUTDOOR AIR 290 CFM 217 E PEOPLE 100 SO. FT. /PERSON @ 200 BTUH /PERSON 3016 N EQUIPMENT 9000 0.25 3.41 7672.5 7673 T INFILTRATION 210 CFM 1617 ROOM LATENT HEAT GAIN = 12522 ITEM QTY FACTOR FACTOR ALTITUDE CORRECTED T DUCT GAINS 6397 0.25 1.00 FACTOR or 2 VALUE 320 H OUTDOOR AIR, SENSIBLE 290 10 0.90 1.10 2870 E OUTDOOR AIR, LATENT 290 11 0.90 0.68 1951 R INFILTRATION 210 CFM 2279 10937 a EXHAUST GRILLE RECTANGULAR DUCT (FIRST FIGURE IS SIDE SHOWN) 1. THI. CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT ''IPING SY TEM BETWEEN THE INDOOR FAN UNITS AND OUTDOOR CONDENSING UNITS. REFER T') PLANS TO DETERMINE IF A REFRIGERANT SYSTEM IS REQUIRED. 2. 'IPING a REFRIGERANT PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBING (AST 1388). TUBING SHALL BE CLEAN, CAPPED AND NITROGEN CHARGED. b. ALL FITTINGS AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI B16.22). ALL COPPER TO COPPER JOINTS SHALL BE BRAZED WITH A COPPER - PHOSPHORUS ALLOY AND ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS -5 ALLOY. c. ALL ELBOWS ARE TO BE LONG RADIUS TYPE. 10 ROUND DUCT 12 0 . OUTSIDE AIR CALCULATION s0 SM OKE DETECTOR -0 AUTOMATIC BACKDRAFT DAMPER ROOM NAME AREA ( SQ.FT.) 0/A PER ASHRAE 62 -99 CFM /SQ.FT. CFM UNDERCUT DOOR 1" T ROOM SENSIBLE LOAD 64359 GRAND TOTAL LOAD (BTUH) 78833 O LATENT LOAD 14474 NOMINAL TONS REQUIRED 6.6 T SENSIBLE HEAT RATIO 0.82 HEATING (BTUH) 44633 A ELECTRIC HEATING (KW) 13.07 L MINIMUM CFM 2819 S COIL INLET (DB /WB) 76 63 r+rr+rn CUSTOMER 545 0.30 164 fb FLEXIBLE DUCTWORK. 5' -O" MAX. SERVICE 333 0.20 67 STORAGE 245 0.15 37 - 1 MANUAL BALANCING DAMPER TOILET 92 0.20 18 DIRECTION OF AIR FLOW UNCONDITIONED 293 TOTAL REQUIRED 286 e CITY OF TUKTNILA OCT 31 Z007 S NEW TO EXISTING CONNECTION TOTAL 1508 TOTAL PROVIDED 290 E D C B A 2 3 4 5 6 7 8 9 10 PERMIT CENTER 0) • : 1 - ) 0 DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817 -251 -8411 W � W rY v a L. W µ 7 W W Q ~ Z W = ▪ U] O o O cI • NL Issue Date Drawn By Appv'd By Revisions Date A \ 9/28/07 A A A A A J5.2.2 VERSION dp 8/21/07 JLP DAR Description City, Customer Comments By AT 00 00 N 0 ti 0 05 -10 -07 5.2.2 Mechanical Specs. & Calculations M -002 R MOT 1 8y DIFFUSERS, GRILLES AND REGISTERS MARK SERVICE LOCATION CLG. TYPE MANUFAC. CATALOG NUMBER REMARKS D-1 SUPPLY CEILING AC. TILE TITUS PAS XX 24x24 3 26 D -75 SEE PLAN FOR NECK SIZE D-2 SUPPLY CEILING GYP TITUS PAS XX 12x12 1 26 D -75 SEE PLAN FOR NECK SIZE D -3 SUPPLY CEILING GYP TITUS TBDI -30 (2x1" SLOTS, 4' LONG) PROVIDE TRIM AS REQUIRED G -1 RETURN CEILING AC. TILE 11TUS PAR 22x22 24x24 3 26 AG -95 100.0 C 2 RELIEF WALL AC. TILE H JS "?45" 26.5 35 YORK D7CG060 850 LBS 10.0/9.1 12 35 zFL N/A ,„„,, _. , .. , / 1 ROOF TOP UNITS MANUFACTURER MARK CAPACITY IN TONS COOLING CAP. (MBH) _ COMPR. . KW HEATING CAP. (MBH) CFM CFM 0/A EXT. S.P. FAN HP ELECTRICAL MANUFACTURER MODEL NUMBER WEIGHT EFFICIENCY TOTAL SENSIBLE INPUT OUTPUT VOLTS PH MCA MOCP SEER /EER AFUE IPLV V07 5 52.0 39.8 5.8 125.0 100.0 1500 150 0.50 1.5 208 3 26.5 35 YORK D7CG060 850 LBS 10.0/9.1 8O% N/A V08 5 52.0 39.8 5.8 125.0 100.0 1500 150 0.50 1.5 208 3 26.5 35 YORK D7CG060 850 LBS 10.0/9.1 80% N/A THERMOSTAT AND SENSORS MARK LOCATION MANUFACTURER MODEL NUMBER REMARKS V05 BACK AREA LICHTSTAT TMD— AVU —RS* FURNISHED AND INSTALLED BY G.C. V06 SALES LIGHTSTAT TMD — REMOTE SENSOR* MOUNT AT 60" A.F.F. EXHAUST FANS MARK LOCATION SERVICE CFM EXT. S.P. (IN W.G.) SONES MOTOR DATA RPM MFR. REMARKS HP VOLTS PH CYC. V09 CEILING TOILET 100 0.25 1.1 -- 120 1 60 — BROAN MODEL L100 * V1 R F nLiNu 2 v9 .2 12 1 C CREENI IECIC ?vi EL 7 D MECHANICAL GENERAL NOTES A "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR 15 TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. B WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSERS, TOILETS, ETC.) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDED RELAMPING ALL LIGHTS REUSED. C EXISTING CONDITIONS ARE BASED ON "AS— BUILT" DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. D CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION /CONSTRUCTION OF NEW WORK. E GENERAL CONTRACTOR SHALL COORDINATE RESPONSIBILITY BETWEEN MECHANICAL AND ELECTRICAL CONTRACTOR, ALL LINE VOLTAGE AND LOW VOLTAGE REQUIREMENTS FOR A COMPLETE PROJECT F COORDINATE DUCT ROUTING AND HEIGHTS WITH GENERAL CONTRACTOR. VERIFY ALL CLEARANCES BEFORE STARTING WORK. G THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT CRITERIA MANUAL. TENANT CRITERIA MANUAL REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH LANDLORD REQUIREMENTS AT NO EXTRA COST TO THE TENANT. H NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. I ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. J CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER FOR RESOLUTION. K ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. L A FREE AREA FOR MAINTENANCE ACCESS AROUND THE HVAC EQUIPMENT SHALL BE PROVIDED. VARIFY CLEARANCE WITH LOCAL CODE AND MANUFACTURERS REQUIERED SERVICE ACCESS. M THE MECHANICAL CONTRACTOR SHALL INSPECT AND RUN TEST ALL EXISTING UNITS AT THE START OF CONSTRUCTION AND INFORM THE OWNER'S REPRESENTATIVE OF ANY NECESSARY REPAIRS FOR APPROVAL IN A TIMELY MANNER TO NOT DELAY THE STORE OPENING DATE. N FILTER MEDIA SHALL BE UTILIZED TO PROTECT ALL RETURN OPENINGS DURING CONSTRUCTION. O FLEX DUCTS SHALL BE LIMITED TO A MAX. LENGTH OF 5' -0" PER BRANCH RUNOUT. P THE GENERAL CONTRACTOR AND MECHANICAL SUB— CONTRACTOR SHALL VERIFY AND INCLUDE IN THEIR FINAL BID ALL LIFE SAFETY, SMOKE /FIRE ALARM SYSTEMS NEEDED TO BRING TENENTS SPACE COMPATIBLE WITH THE LANDLORD'S SYSTEM., AND CURRENT WITH LOCAL AND STATE CODES. FAILURE TO DO SO SHALL RESULT IN NO EXPENSE TO THE TENANT. NECK AND RUNOUT SIZE. (SUPPLY TRANSITION AS REQUIRED TO CONNECT BRANCH DUCT AS SHOWN) CUBIC FEET PER MINUTE DIFFUSER /GRILLE TAG 2 3 A 1 0I J r . B AL i r, • G -1 300 WPM .4 • ■, 6o- 450 CFM 12 D -1 50 CFM 1CO 1 V09 6 50 6 " 0 0 6 ,. D--- -2 COOLING CAPACITIES BASED ON ARI STANDARD 210/240 -89: 80° F DB/ 67° F WB INDOOR ENTERING AIR TEMPERATURE, 95' F DB AIR ENTERING OUTDOOR FAN. SCHEDULED UNIT CFM MAY DIFFER FROM ARI STANDARD CFM. 1. CONDENSING COILS SHALL BE PROTECTED WITH FACTORY APPLIED COIL COATING. 2. UNIT SHALL BE FURNISHED WITH DIFFERENTIAL ENTHALPY ECONOMIZER. CAPABLE OF 100% OUTSIDE AIR DIFFUSER /GRILLE TYPE 3. UNIT TO BE FURNISHED WITH TWO SET OF STANDARD FILTERS. CONTRACTOR TO REPLACE FILTERS PRIOR TO TURNING STORE OVER TO TENANT. (REFER TO SCHEDULE) 4. UNIT SHALL INCLUDE A FULL PERIMETER ROOF CURB. 5. ALL ROOF WORK INVOLVED WITH SETTING OF THE ROOF CURB AND UNIT SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR. LANDLORD SHALL PROVIDE ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT RTU, PER LANDLORD'S REQUIREMENTS. 6. LANDLORD TO SUBMIT MANUFACTURER'S INSTALLATION INSTRUCTIONS TO BUILDING DEPARTMENT. 7. FURNISH UNIT WITH MFG OPTIONAL POWER EXHAUST IF AVAILABLE. * FURNISH WITH AUTOMATIC BACKDRAFT DAMPER; INTERLOCK WITH LIGHT SWITCH. 450 CFM 12 "0 D-1 12 "0 2 —WAY 500 CFM D-1 - W _ WAIN Q,. G -1 ,0 0 * DO NOT LOCATE UNDER NIGHT LIGHT FIXTURE. ALSO, DO NOT INSTALL ABOVE ANY HEAT GENERATING EQUIPMENT. D" E — TB - ' ,1 V05' CFM I ' 6 " TT£ 400 12 400 12 "0 MECHANICAL PLAN SCALE: 1/4" = 1' -0" CFM D -1 CFM D -1 12 "0 9 10 400 CFM . 12,E I D -3 MECHANICAL KEYED NOTES NORTH al EXISTING ROOFTOP UNIT BY LANDLORD. CONTRACTOR SHALL VERIFY LOCATION, ORIENTATION, DIMENSIONS AND EXISTING CONDITIONS. CONTRACTOR SHALL ADJUST DUCTWORK AS REQUIRED. SET UNIT TO DELIVER AIR QUANTITY SPECIFIED. ® ROUTE 6 "0 EXHAUST DUCT FROM EXHAUST FAN TO 8 "0 DUCT THRU ROOF (FIELD VERIFY). FURNISH AND INSTALL WITH BACKDRAFT DAMPER, ROOF CAP AND ACCESSORIES AS REQUIRED. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. EXHAUST VENT TO BE A MINIMUM OF 10' —O" FROM ANY FRESH AIR INTAKE. RECEIVED CITY OF TUKV` O UNDERCUT DOOR 1 ". COORDINATE WITH THE OWNER'S FIELD REPRESENTATIVE. ,I 3 1 2001 • CONTRACTOR TO FURNISH AND INSTALL RIGID 4 "0 DRYER EXHAUST DUCT FROMEHIVIIT CENT DRYER UP THRU ROOF WITH RAIN CAP. THE RIGID MOISTURE EXHAUST DUCT SHALL NOT EXCEED 15 FEET INCLUDING 2 -90° ELBOWS OR AS ALLOWED BY DRYER MANUFACTURER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. EXHAUST VENT TO BE A MINIMUM OF 10' ---0" FROM ANY FRESH AIR INTAKE. 0 DUCT SMOKE DETECTOR ON SUPPLY SIDE DUCT AND SHUTDOWN RELAY SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. ALL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. ® FLU VENT PIPE THRU ROOF FROM WATER HEATER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. LOCATE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. SEE DETAIL 2/M-501. DON PENN CONSULTING ENGINEER 4 A A 0 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817- 410 -2858 FAX 817- 251 -8411 Issue Date Drawn By Appv'd By Revisions Date 9/28/07 J5.2.2 VERSION e), dp JLP co 00 CT) DAR M -101 8/21/07 Description City, Customer Comments Q O E C z 0 0 CA 0 W 0 0 By AT 0 co co ti W m z I- 0 0 W cG 0 05 -10 -D7 5.2.2 Mechanical Plan e REVISION NOt M O7 1 9zJ JAMBA JUICE Arlington, Texas V07 s 18" �� Q Ca 7 1 = 0 1 E31 D MECHANICAL GENERAL NOTES A "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR 15 TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. B WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSERS, TOILETS, ETC.) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDED RELAMPING ALL LIGHTS REUSED. C EXISTING CONDITIONS ARE BASED ON "AS— BUILT" DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. D CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION /CONSTRUCTION OF NEW WORK. E GENERAL CONTRACTOR SHALL COORDINATE RESPONSIBILITY BETWEEN MECHANICAL AND ELECTRICAL CONTRACTOR, ALL LINE VOLTAGE AND LOW VOLTAGE REQUIREMENTS FOR A COMPLETE PROJECT F COORDINATE DUCT ROUTING AND HEIGHTS WITH GENERAL CONTRACTOR. VERIFY ALL CLEARANCES BEFORE STARTING WORK. G THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT CRITERIA MANUAL. TENANT CRITERIA MANUAL REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH LANDLORD REQUIREMENTS AT NO EXTRA COST TO THE TENANT. H NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. I ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. J CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER FOR RESOLUTION. K ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. L A FREE AREA FOR MAINTENANCE ACCESS AROUND THE HVAC EQUIPMENT SHALL BE PROVIDED. VARIFY CLEARANCE WITH LOCAL CODE AND MANUFACTURERS REQUIERED SERVICE ACCESS. M THE MECHANICAL CONTRACTOR SHALL INSPECT AND RUN TEST ALL EXISTING UNITS AT THE START OF CONSTRUCTION AND INFORM THE OWNER'S REPRESENTATIVE OF ANY NECESSARY REPAIRS FOR APPROVAL IN A TIMELY MANNER TO NOT DELAY THE STORE OPENING DATE. N FILTER MEDIA SHALL BE UTILIZED TO PROTECT ALL RETURN OPENINGS DURING CONSTRUCTION. O FLEX DUCTS SHALL BE LIMITED TO A MAX. LENGTH OF 5' -0" PER BRANCH RUNOUT. P THE GENERAL CONTRACTOR AND MECHANICAL SUB— CONTRACTOR SHALL VERIFY AND INCLUDE IN THEIR FINAL BID ALL LIFE SAFETY, SMOKE /FIRE ALARM SYSTEMS NEEDED TO BRING TENENTS SPACE COMPATIBLE WITH THE LANDLORD'S SYSTEM., AND CURRENT WITH LOCAL AND STATE CODES. FAILURE TO DO SO SHALL RESULT IN NO EXPENSE TO THE TENANT. NECK AND RUNOUT SIZE. (SUPPLY TRANSITION AS REQUIRED TO CONNECT BRANCH DUCT AS SHOWN) CUBIC FEET PER MINUTE DIFFUSER /GRILLE TAG 2 3 A 1 0I J r . B AL i r, • G -1 300 WPM .4 • ■, 6o- 450 CFM 12 D -1 50 CFM 1CO 1 V09 6 50 6 " 0 0 6 ,. D--- -2 COOLING CAPACITIES BASED ON ARI STANDARD 210/240 -89: 80° F DB/ 67° F WB INDOOR ENTERING AIR TEMPERATURE, 95' F DB AIR ENTERING OUTDOOR FAN. SCHEDULED UNIT CFM MAY DIFFER FROM ARI STANDARD CFM. 1. CONDENSING COILS SHALL BE PROTECTED WITH FACTORY APPLIED COIL COATING. 2. UNIT SHALL BE FURNISHED WITH DIFFERENTIAL ENTHALPY ECONOMIZER. CAPABLE OF 100% OUTSIDE AIR DIFFUSER /GRILLE TYPE 3. UNIT TO BE FURNISHED WITH TWO SET OF STANDARD FILTERS. CONTRACTOR TO REPLACE FILTERS PRIOR TO TURNING STORE OVER TO TENANT. (REFER TO SCHEDULE) 4. UNIT SHALL INCLUDE A FULL PERIMETER ROOF CURB. 5. ALL ROOF WORK INVOLVED WITH SETTING OF THE ROOF CURB AND UNIT SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR. LANDLORD SHALL PROVIDE ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT RTU, PER LANDLORD'S REQUIREMENTS. 6. LANDLORD TO SUBMIT MANUFACTURER'S INSTALLATION INSTRUCTIONS TO BUILDING DEPARTMENT. 7. FURNISH UNIT WITH MFG OPTIONAL POWER EXHAUST IF AVAILABLE. * FURNISH WITH AUTOMATIC BACKDRAFT DAMPER; INTERLOCK WITH LIGHT SWITCH. 450 CFM 12 "0 D-1 12 "0 2 —WAY 500 CFM D-1 - W _ WAIN Q,. G -1 ,0 0 * DO NOT LOCATE UNDER NIGHT LIGHT FIXTURE. ALSO, DO NOT INSTALL ABOVE ANY HEAT GENERATING EQUIPMENT. D" E — TB - ' ,1 V05' CFM I ' 6 " TT£ 400 12 400 12 "0 MECHANICAL PLAN SCALE: 1/4" = 1' -0" CFM D -1 CFM D -1 12 "0 9 10 400 CFM . 12,E I D -3 MECHANICAL KEYED NOTES NORTH al EXISTING ROOFTOP UNIT BY LANDLORD. CONTRACTOR SHALL VERIFY LOCATION, ORIENTATION, DIMENSIONS AND EXISTING CONDITIONS. CONTRACTOR SHALL ADJUST DUCTWORK AS REQUIRED. SET UNIT TO DELIVER AIR QUANTITY SPECIFIED. ® ROUTE 6 "0 EXHAUST DUCT FROM EXHAUST FAN TO 8 "0 DUCT THRU ROOF (FIELD VERIFY). FURNISH AND INSTALL WITH BACKDRAFT DAMPER, ROOF CAP AND ACCESSORIES AS REQUIRED. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. EXHAUST VENT TO BE A MINIMUM OF 10' —O" FROM ANY FRESH AIR INTAKE. RECEIVED CITY OF TUKV` O UNDERCUT DOOR 1 ". COORDINATE WITH THE OWNER'S FIELD REPRESENTATIVE. ,I 3 1 2001 • CONTRACTOR TO FURNISH AND INSTALL RIGID 4 "0 DRYER EXHAUST DUCT FROMEHIVIIT CENT DRYER UP THRU ROOF WITH RAIN CAP. THE RIGID MOISTURE EXHAUST DUCT SHALL NOT EXCEED 15 FEET INCLUDING 2 -90° ELBOWS OR AS ALLOWED BY DRYER MANUFACTURER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. EXHAUST VENT TO BE A MINIMUM OF 10' ---0" FROM ANY FRESH AIR INTAKE. 0 DUCT SMOKE DETECTOR ON SUPPLY SIDE DUCT AND SHUTDOWN RELAY SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. ALL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. ® FLU VENT PIPE THRU ROOF FROM WATER HEATER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. LOCATE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. SEE DETAIL 2/M-501. DON PENN CONSULTING ENGINEER 4 A A 0 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817- 410 -2858 FAX 817- 251 -8411 Issue Date Drawn By Appv'd By Revisions Date 9/28/07 J5.2.2 VERSION e), dp JLP co 00 CT) DAR M -101 8/21/07 Description City, Customer Comments Q O E C z 0 0 CA 0 W 0 0 By AT 0 co co ti W m z I- 0 0 W cG 0 05 -10 -D7 5.2.2 Mechanical Plan e REVISION NOt M O7 1 9zJ JAMBA JUICE Arlington, Texas WHERE REQUIRED, PROVIDE ROUND DUCT VOLUME DAMPER WITH STRAP OR ANGLE TRAPEZE HANGERS LOCKING QUADRANT. PROVIDE WITH 3" EXTENDED SHAFT DAMPER HANDLE TO BE AND HANDLE INSTALLED MAXIMUM OF 3'-O" ABOVE CEILING. SHT. MTh. ELBOW REQUIRED SECURELY TAPE VINYL FLEX DUCT ROD / \ ROOF JOIST 1 TO SHT. MTL. W/ MIN. OF (2) CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FLEX DUCT INSULATION & VINYL TO SHT. TABLE 4 - - RECTANGULAR DUCT HANGERS - MINIMUM SIZE MAX. HALF OF DUCT PERIMETER PAIR AT 10' SPACING PAIR AT 8' SPACING PAIR AT 5' SPACING PAIR AT 4' SPACING MTL. TAPE INSULATION TO DUCT TO A STRAP WIRE /ROD STRAP WIRE/ROD STRAP WIRE /ROD STRAP WIRE /ROD Ill �J P „ —= 30 2 1 "x22 ga. 1 ga (_135) 1" x 22 ga. 10 ga. (.135) 1 ' x 22 ga. 1 2 ga. (.106 ° ) 1" x 22 ga. 12 ga. (.106 ° ) �� 18 LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO FORM A GOOD SEAL _ I 8" LONG SHT. MTL. SECTION SIZE BOLT(S) FOR LOAD STRAP HANGERS IDENTIFY LOCATION INSULATED FLEXIBLE CONNECTION ") SECURED TO DIFFUSER COLLAR W/ MIN. (3) SHT. MTL. SCREWS, DUCT TAPE AND MASTIC. TRANSITION FROM DUCT p 72" 1" x 18 ga. - 3/8" in x 20 ga. 1/4" in x 22 ga. 1/4" 1" x 22 ga. 1/4" 2 = HANGER STRAP SHEET MTL. DUCT HANGER SCREWS HANGER UNLESS FOOT OF " 1' x 16 a g 3 8 / " r x 18 9 a. 3/8" 1" x 20 go. 3 8" / 1" x 2 a. 9 1/4' —= 96 2 (MAX_ 5' -0 FIRE DAMPER WHERE INDICATED PLANS. STRAPS STRAP IS PLACED UNDER A BOTTOM REINFORCEMENT MAY BE OMITT IF HANGER LOOPS SIZE TO DIFFUSER NECK SIZE AS NECESSARY I THERMAL INSULATING BLANKET — REQUIRED FOR FIRE RATED P = 120" 2 1 1/2" x 16 ga. 1/2" 1" x 16 ga. 3/8" 1" x 18 ga. 3/8" 1" x 20 ga. 1/4" 60" MAX. I I I I I ON 1111111 ,, 168" 2 1 1/2" x 16 ga. 1/2" 1 1/2" x 16 ga. 1/2" r x 16 ga. 3/8" 1" x 18 ga_ 3/8 —,--1 CEILINGS ONLY. = P " 2 = 192 - 1/2" 1 1/2" x 16 ga. 1/2" 1" x 16 ga. 3/8" 1" x 18 ga. 3/8' til SPIRAL DUCT HA \GER , INSULATION SPIRAL DUCT DETAIL 1.... CEILING MOUNTING LAY IN SUPPLY AIR DIFFUSER APPLICATION (BORDER TYPE 3). FOR GYP. CEILING P = 193 "aP 2 SPECIAL ANALYSIS REQUIRED 1 ° � MIN. 1 CEILI (LAY -IN FRAME) \G DIFFUSER vOU APPLICATION USE SURFACE MOUNTED DIFFUSER (BORDER TYPE 1). \TI \G DETAIL NOTE: FOR ADDITIONAL INFORMATION REFER TO THE LATEST EDITION OF SMACNA 8 RECTANGULAR DUCT HANG -R ATTACHVE \T DETAIL SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. • A B _ ALTERNATE TAP LOCATION. MAX FLEX DUCT LENGTH = 5' -0 ". NO TURNS GREATER THAN (1) ° NOTES: MECHANICAL EQUIPMENT. WHICH EXCEED 9" SQUARE AT • LLS (NOT RIBBED OR DEFORME► REBAR). OR PEEN NUT TO BOLT. 1. COORDIN • '1 BURGLAR BARS WITH 2. INSTALL BUR. AR BARS AT OPENINGS AND /OR ROOF 0'. INGS. 3. #6 BARS TO HAVE MOOTH SURFACE 4. AFTER BARS ARE INS LED WELD z o I 7.-) _ A` VENT TOP aim PLASTIC CEMENT STORM COLLAR ROOF FLASHING 9 TURN PERMITTED. SUPPLY DUCT ROOF AND INSULATION DECK 0 1/4 i - / , END OF DUCT � 1� AF LO� 1/4" (/ A A — 15 OR LESS PIPE VENT AIR FLOW 15' OR LESS .. O AIR LO r % j = FLEX DUCT � I lir 1.41 #6 CROSS BARS © 6 ON CENTER (5 MAX TRANSFORMATION EXPANSION CONTRACTION � D CEILING = LENGTH) NOTE ��� PATCH AND REPAIR ROOF AS NECESSARY TO MATCH (E) COORDINATE WITH LANDLORD'S ROOFING CONTRACTOR, TYP. TO MAINTAIN ROOF WARANTY. A #6 BARS ® 6° ON CENTER 4" X 2 -1/2" F.B. '.ME DIFFUSER D IEE�.,SER DUCT CON 8c RECTA \ECT 0\ \G,.LAR TURNING VANES TURNING VANE x 2 �`�� ( 4 B�.RGLAR BARS F - ATTACH TO STR TURAL FRAMING WITH 2" DIAMETER M AT 8" ON CENTER -- MINIMU 2 M.B. EACH SIDE OF BA DUCT LINING DETAIL _ _,�. GAS APPLIA \CE VE\ T `L � �� THREE TURNING VANES 2/3D 90 p ELBOW SCALE: N.T.S. SCALE: N.T. . SCALE: N.T.S. 45° ELBOW SIMILAR NO THROAT RADIUS SHORT RADIUS FULL RADIUS 7 a #10 2" SHT. ETAL ` H _. • ' a ; s:. , ..,:.:∎ �'• ' t' ..�t - Z• f • i • • •"•'.' '•' �mau" n � � • ;•n 4:: �•. "., " •. s - PIPE OR CONDUIT REDWOOD ON CENTER GALV. METAL SECURED WITH , �� � 1 r .�: ': '' r r rM INVERTED BITUMEN W/ MASTIC BLOCKING AT 6' -0" MAXIMUM FASTENER LAG SCREWS - wti, • • � + " 'f' ' .. n n ' nn• f J ~; ... ' ""'•• MODIFIED CAP SHEET SET CEMENT _i `b ¢ z CURB MOUNTED SCREWS (: 'ER UNIT) NEOP' NE GASKET FA ORY CURB TURN ROOFING TO EXTEND CURB RETURN TO FULLY COVER WOOD NAILER. - 1 7 O mm ~ X • z r- -4- LA CAP z z 0 I � - n STORM COLLA N , A/C UNIT SUPPLY OR RETURN WYE TURNING VANES vr w CLzz o- - nr� LEVELING OF CURB BY G.C. >I (RECTANGULAR DUCT) ° 1 11 . 11 Q x ROOF ' RIGID INSULATION BY i n, � INSULATION STRIP BY �4 -4 G.C. (HARD INSULATION _+, � INSET FOR TOE KICK FLASHING / \ 2 o N BY G.C. EXH_ DUCT ROOF .Z V V_ A�ugHt/I7Ht A ,r PROTECTION) PROTEC � - Di Wiffi I iiii ....._ 3/4 D 90° ELBOW TAKE —OFF FACTORY CURB RETURN AIR BRANCH USE ONLY IN AREAS FULL RADIUS ELBOW �� N_OTE 14" HIGH MIN ROOFING PATCH AND REPAIR ROOF AS NECESSARY TO MATCH (E) COORDINATE WITH CONTRACTOR, TYP. TO LANDLORD'S ROOFING COR MAINTAIN ROOF WARANTY. FITTING WHERE SPACE IS LIMITED TAKE —OFF DUCT THRU ROOF 9 D,CTWOR< DETAILS NOTE: FROM 6 EXHAUST AIR RESTROOM DUCT DETAIL PATCH A I REPAIR ROOF AS NECESS - 'Y TO MATCH (E) COORDIN • '' WITH LANDLORD'S Rig ING CONTRACTOR, ` TO MAINTAIN ROOF WA NTY. NOTE: (E) BUILT -UP ROOFING - VERIFY IN FIELD RECEIVED CITY OF TUKV /ILA PATCH AND REPAIR ROOF AS NECESSARY TO MATCH (E) COORDINATE WITH LANDLORD'S ROOFING CONTRACTOR, TYP. ROOFING CONTRACTOR, TO MAINTAIN ROOF WARANTY. "TU PAC CURB ASSEvBLY '<AGE WITH DETAIL PIPE SUPPORT BLOC�I OCT zoos \G p�b�MITCENTER SCALE: N.T.S. SCALE: N.T.S. SCALE: N. SCALE: N.T.S. E D C B A 2 3 4 5 6 7 8 9 10 01, A A A A A A Drawn By Appv'd By Revisions D ate J5.2.2 VERSION a a 12 u cg Z W a m 'Z G m I a = o O Issue Date C pe,'" 0 ism it dp DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817- 251 -8411 CO CO r Description M -501 8/21/07 JLP DAR U, 0 W 0 0 p A C4 C.) UJ LU cc a X By O a r. Co oo N ti 0 e 05 -10 -07 5.2.2 Mechanical Details REVISI NNOei t/O 8'1 3 4 GENERAL NOTES V07 C GFI WP r — EX ON L IC— — J 60 /40/2 NEMA 3R "Zr J EXISTING 60 /NF /3 NEMA 3R L- 104 - 31,33,35 ( # 104-27 30/30/2 NEMA 3R ON L- 104 -29 D A "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. B WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSERS, TOILETS, ETC.) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER_ ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDED RELAMPING ALL LIGHTS REUSED. C REFER TO MECHANICAL DRAWINGS FOR EXACT SIZE, LOCATION, AND ELECTRICAL REQUIREMENTS FOR ALL MOTORS AND MECHANICAL EQUIPMENT. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. D ALL NEW POWER AND LIGHTING CONDUITS ON THIS PROJECT SHALL INCLUDE AN INSULATED GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS NOTED OR PER NEC WHERE NOT NOTED. THIS GROUNDING CONDUCTOR SHALL BE PROVIDED REGARDLESS OF THE TYPE OF CONDUIT USED. E EXISTING CONDITIONS SHOWN ARE BASED ON AS —BUILT DRAWINGS PROVIDED BY THE 'OWNER AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. 7 NOTE: ROOFTOP UNIT IS PROVIDED AND INSTALLED BY LANDLORD UNDER LANDLORD'S WORK. LANDLORD'S CONTRACTOR SHALL COORDINATE FINAL LOCATION WITH LANDLORD'S STRUCTURAL ENGINEER. LANDLORD'S CONTRACTOR SHALL PROVIDE ANY ADDITIONAL STRUCTURAL BRACING REQUIRED. .I 0 L E 1) <I V08 MECHANICAL KEYED NOTES EXISTING 60 /NF /3 NEMA 3R L- 104 - 37,39,41 ( # 0 ROUTE 8 "0 EXHAUST DUCT THRU ROOF (FIELD VERIFY). FURNISH AND INSTALL WITH BACKDRAFT DAMPER, ROOF CAP AND ACCESSORIES AS REQUIERED. M2 OUTSIDE AIR INTAKE TO BE A MINIMUM OF 1O' -0" FROM ANY VENT OR EXHAUST OPENING. 27 L- 104 -29 M.E.P. ROOF PLAN SCALE: 1 /4" = 1' -0" 0 CONTRACTOR TO FURNISH AND INSTALL RIGID 4 "0 DRYER EXHAUST DUCT FROM DRYER UP THRU ROOF WITH RAIN CAP. THE RIGID MOISTURE EXHAUST DUCT SHALL NOT EXCEED 15 FEET INCLUDING 2 -90° ELBOWS OR AS ALLOWED BY DRYER MANUFACTURER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. EXHAUST VENT TO BE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. M4 FLU VENT PIPE THRU ROOF FROM WATER HEATER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. LOCATE A MINIMUM OF 1O' -0" FROM ANY FRESH AIR INTAKE. SEE DETAIL 2/M -501. @ WALK —IN COOLER AND FREEZER CONDENSING UNITS MOUNTED ON ROOF. VERIFY REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION. 4/ ,#N oc, 9 10 ELECTRICAL KEYED NOTES 1/, NORTH E1 EXISTING ROOFTOP UNIT BY LANDLORD. CONTRACTOR SHALL VERIFY LOCATION, ORIENTATION, DIMENSIONS AND EXISTING CONDITIONS. CONTRACTOR SHALL ADJUST DUCTWORK AS REQUIRED. SET UNIT TO DELIVER AIR QUANTITY SPECIFIED. E2 LANDLORD SHALL FURNISH, INSTALL AND WIRE COMPLETE DUCT SMOKE DETECTOR AND ASSOCIATED AUDIBLE /VISUAL NOTIFICATION AS REQUIRED BY NFPA 90A. PROVIDE AUDIBLE /VISUAL ALARM AND TEST/ RESET SWITCH ABOVE CASH REGISTER LOCATION. DETECTION SYSTEM SHALL BE AS MANUFACTURED BY EDWARDS OR APPROVED EQUAL. E3 ROUTE CIRCUIT WIRING TO FREEZER EVAPORATOR BELOW. REFER TO SHEET E -102 FOR CONTINUATION. PLUMBING KEYED NOTES 0 3" VENT THROUGH ROOF. SEE SHEET P -102 FOR CONTINUATION. VENT SHALL BE A MINIMUM OF 1O' —O" FROM ANY FRESH AIR INTAKE. 0 EXISTING 1" CONDENSATE TO NEAREST CODE APPROVED DISPOSAL SITE. VERIFY LOCATION IN FIELD. 0 EXISTING 1" GAS PIPING DOWN TO FLOOR BELOW. SEE SHEET P -103 FO RECEIVED CONTINUATION. C ITY OF TUKWILA OCT 31 2007 PEHMIT CENTER A A A A A 0), > alt a. W a rY C3 • w 0 re a 7 W w l I - o ea Z W Q = 0 7 co C 1.4. Issue Date Drawn By Appv'd By Revisions Date 9/28/07 J5.2.2 VERSION JLP dp DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817 -251 -8411 DAR J J L16 8/21/07 Description City, Customer Comments 0 0 O 0 OG 0 W 0 0 By AT 10 •o n • 05 -10 -07 5.2.2 M.E.P. Roof Plan MEP -101 REVISIII NOiL MO'7 ($y DIVISION 15 - MECHANICAL SECTION 15000 BASIC MECHANICAL REQUIREMENTS A. NOTE 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WITH JAMBA JUICE'S SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS WORK. 5. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT THE BID. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR JAMBA JUICE SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND JAMBA JUICE'S PROJECT MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRU PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 7. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY JAMBA JUICE'S PROJECT MANAGER AND THE LANDLORD. ALL PATCHING SHALL BE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES. 8. THE MECHANICAL CONTRACTOR SHALL MAKE ALL FINAL MECHANICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. a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a. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. b. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. c. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TO KEEP THESE RECORDS WILL ALLOW JAMBA JUICE TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE THESE RECORDS AT HIS EXPENSE PRIOR TO FINAL PAYMENT. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE JAMBA JUICE'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, JAMBA JUICE'S PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. PHASING REQUIREMENTS 1. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S HVAC, PLUMBING AND SPRINKLER SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE IN WRITING WITH JAMBA JUICE'S PROJECT MANAGER AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE HVAC, PLUMBING OR FIRE PROTECTION SYSTEMS. K DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING HVAC UNITS, HYDRONIC PIPING, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL / FLOOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DIELECTRICALLY SEPARATED. FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, JAMBA JUICE SHALL HAVE AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. END OF SECTION 15000 an review approval is subject to errors and omi; Approval of construction documents does not authorize the violation cf r.ny accepted code or ordinance. Receipt of approved r � 4 -d co ns Is acknot viedged: BY City of Tukwila BUILDING DIVISION SPECIFICATIONS SEPARATE PERMIT REQUIRED FOR D� • � / aectricad I Plumbing OF Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shah be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include 9dditinnal plan review fees. SECTION 15500 HEATING, VENTILATION AND AIR CONDITIONING A. B. C. D. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE HVAC SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: HVAC UNITS, ALL RELATED EQUIPMENT AND ACCESSORIES (UNLESS NOTED OTHERWISE). DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. HYDRONIC PIPING. (AS APPLICABLE, REFER TO PLANS). REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS)_ CURBS, ROOFING, AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). f. TESTING, ADJUSTING, AND BALANCING. 9. KEEPING A RECORD SET AND PREPARE AS -BUILT DRAWINGS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOBSITE AND EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES TO MEET STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. a. b. c. d. e. 6 7 HVAC EQUIPMENT 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED PER THE RESPONSIBILITY SCHEDULE, UNLESS NOTED OTHERWISE. REFER TO PLANS FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3- EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 4. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO CAPTURE POTENTIAL LEAKS FROM THE ENTIRE UNIT. PROVIDE CONDENSATE PUMPS AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. (PARAGRAPH OMITTED) METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO JOB SITE VISIT AND APPROVAL BY THE GENERAL CONTRACTOR. A SKETCH MUST BE SUBMITTED INDICATING DEVIATIONS FROM DESIGN AND MUST BE APPROVED BY JAMBA JUICE'S PROJECT MANAGER PRIOR TO FABRICATION OR INSTALLATION. 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. WHERE OTHER CODES ARE ENFORCED, (IE. UMC, BOCA, ETC.) USE THE MOST STRINGENT CODE FOR DUCT CONSTRUCTION STANDARDS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: 2" W.G., POSITIVE RETURN AND EXHAUST DUCTS: 2" W.G., NEGATIVE EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: CLASS B --- 3" W.G. RETURN AND EXHAUST DUCTS: CLASS C - 2" W.G. IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. 4. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCKSEAM CONSTRUCTION FOR ALL SIZES 14" DIAMETER AND LARGER_ ROUND DUCTWORK SIZES 13" DIAMETER AND SMALLER MAY BE SNAP -LOCK CONSTRUCTION. ALL SNAP -LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL WITH SPOT WELDED AND BONDED CONSTRUCTION. 5. ROUND SPIRAL GALVANIZED STEEL DUCTWORK MAY BE USED IN PLACE OF RECTANGULAR DUCTWORK IN HORIZONTAL APPLICATION WHEN ABOVE CEILING CLEARANCES PERMITS AND EQUIVALENT FREE AREA IS MAINTAINED, WITH THE FOLLOWING EXCEPTION; ALL SUPPLY AND RETURN DUCTWORK WITHIN 15 FEET OF THE AIR HANDLER MUST BE RECTANGULAR AND INTERNALLY LINED. ONCE A TRANSITION IN THE DIRECTION OF THE AIRFLOW TO SPIRAL HAS BEEN DONE, DUCT WILL NOT BE ALLOWED TO REVERT TO RECTANGULAR. WHERE ROUND DUCT SUBSTITUTION WILL TAKE PLACE, SUBMIT A SKETCH AND CHART SHOWING EQUIVALENT ROUND CONVERSIONS OF RECTANGULAR DUCTWORK TO JAMBA JUICE'S PROJECT MANAGER FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION. 6. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS IN MAIN DUCT PER LATEST EDITION OF SMACNA. 7. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 8. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE A MINIMUM 1 -1/2" x 1-1/2" x 1/8" STEEL ANGLE FRAME AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 9- ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASSFIBER - FABRIC REINFORCED TAPE. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. 10. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 11. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. D. K. METAL DUCTWORK (CONTINUED) 12. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY JAMBA JUICE'S PROJECT MANAGER PRIOR TO INSTALLATION. IN HARD CEILINGS, LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WHEN WITHIN 3'--0" OF DEVICE. 13. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. VAV BOX, DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. • • • ■ : - � ■ • EDIUM PRESSURE DUCT 1. WH CONSTRUC OF 4 INCHES WA WITH "LO- LOSS" 4. ALL 0 1. 9 10 UCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT ACCORDANCE WITH SMACNA STANDARDS FOR LUMN MINIMUM OR GREATER AS 2. ALL GAUGES AND REINFORCE STANDARDS FOR MEDIUM PRESSURE 3. CONNECTIONS TO THE LA FIRE /FIRE SMOKE DAMPERS DUCTWORK INSULATION 'S MEDIUM PRES TEE TAPS OR AS OTHERWISE R S E SSURE RATING ED BY LANDLORD. MUST MEE "' THE LATEST EDITION OF SMACNA ND WITH THE LANDLORD'S CRITERIA. DUCTWORK SHALL BE MADE D BY THE LANDLORD EMS FROM METAL DUCTWORK SPECIFICATION SECTION ON, WITH THE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK M WRAPPED INSULATION, NOT LINED. TO THIS F. VIBRATION ISOLATION DEVICES 1. SPRING VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND STRUCTURE. ISOLATORS TO BE SIZED ACCORDING TO LOAD WITH A MIN. 1" DEFLECTION. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 2. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. 3. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 4. CONSULT MANUFACTURER FOR APPLICATION DATA. G. FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE - COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. H. FLEXIBLE AIR DUCT 1. FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1, UL LISTED AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS ON THE DRAWINGS. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS. 3 - FLEXIBLE DUCT SHALL NOT EXTEND OVER 5' -0" IN LENGTH AT ANY ONE LOCATION. SUPPLY AIR TAKE -OFF FITTINGS 1. FURNISH AND INSTALL CONICAL, TAPERED OR 45 DEGREE SADDLE TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALLATION SHALL BE PER SMACNA LATEST EDITION. J DAMPERS 1. WHERE DESIGNATED, FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. DURODYNE MODEL NO: K SERIES QUADRANT. 2. OPERATING HANDLES ON ALL DAMPERS SHALL BE TAGGED WITH A MINIMUM 18" LONG ORANGE MARKER TAPE. 3. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, A REMOTE DEVICE, MANUALLY OPERATED SHALL BE USED. UNITS SHALL BE ORDERED THREE WEEKS BEFORE INSTALLATION TO ALLOW FOR DELIVERY LEAD TIME. 1. FURNISH AND INSTALL PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED AND MEET ALL CODE REQUIREMENTS. 2. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 DEGREE F FUSIBLE LINK, TYPE B, AS MINIMUM. FURNISH AND INSTALL ACCESS DOORS AS NECESSARY. 3. FURNISH AND INSTALL ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND CODE REQUIREMENTS. 4. FIRE SMOKE DAMPERS SHALL BE FURNISHED AND INSTALLED WITH ELECTRIC POWERED MECHANISM. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER REQUIREMENTS. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. ALL SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK SHALL BE INTERNALLY INSULATED WITH 1" THICK, 1 -1/2 LB. DENSITY LINE (C =0.28 © 75 DEGREE F). WHEN A COMPLETE DUCTED RETURN AIR SYSTEM IS INDICATED ON THE DRAWINGS, ONLY THE 15' -0" OF THE RETURN AIR DUCT CLOSEST TO THE AIR HANDLING UNIT IS TO BE INSULATED. LINER IS TO HAVE A COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES TO BE COATED WITH ADHESIVE. 3. DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1 1/2" THICK, 1# DENSITY (R =5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM, EXCEPT LINED DUCTWORK SPECIFIED ELSEWHERE AND EXHAUST DUCTWORK. ALL JOINTS MUST BE OVERLAPPED AND TUCKED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND OTHER PENETRATIONS. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. . GTI= I IV V V RECEIVED I T # CITY OF Revisions Date A A Issue Date Drawn By Appv'd By J5.2.2 VERSION dp DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817 -251 -8411 C Q []L co co _ y µ o ) z 2< pOZ ~ 2 ° o = �' o ' o • JLP DAR M -007 Description ski' 1 8/21/07 BUILD a fTVTCTn By Mechanical Specs. 05 -10 -07 5.2.2 UKVVILA SIP 0 d 7n111 PERMIT CENTER F CONTINUED FROM SHEET M -001 SECTION 15500 HEATING, VENTILATION AND AIR CONDITIONING M. HYDRONIC PIPING 1. FURNISH AND INSTALL A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC SYSTEM IS REQUIRED. 2 PIPING rI • \ • w i • 1 I , a. b. AL PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LE MIN UM PRESSURE OF 125 PSI. c. ALL YDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PI NG SYSTEM SHAL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE ',TRAINER SCREE .5. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND 1UIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SY EM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FR iM THE LANDLORD'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO '.0 FROM THE LANDLORD • FIELD REPRESENTATIVE. ANY RUNS THRU A CHAS OR SHAFT WILL BE DONE WITH FEWEST JOINTS POSSIBLE USING THE LONGEST LEN TH OF HARD COPPER PIPL AVAILABLE. SHOULD A JOINT BE REQUIRED, CO RACTOR SHALL MAKE ALL E ORTS TO KEEP THE JOINTS IN ACCESSIBLE AR AS. d. 3. VALVES a. GATE VALVES, 2 -IN ASTM B 62 CAST BR RENEWABLE SOLID BR RE-PACKABLE UNDER SUBSTITUTION. b. c. SWING CHECK VALVES, 2 -IN AND CAP CONFORMING TO A RENEWABLE BRONZE DISC, AN d. a . b. a. 1. THI SY T C. HYDRONIC PIPING FOR CHILLED WATER, CONDENSER WATER AND /OR HEATING WATER SHALL BE ASTM A -53, SCHEDULE 40, ERW, BLACK STEEL PIPE WITH P AIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2-1/2 INCH AND LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS. INSTALL TYPE "K" COPPER PIPE FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNI iNS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMAN E WITH STM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER IS MOST STRING NT. NIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHER SERVICE REMOVAL MAY BE REQUIRED. PRIOR TO CO ECTION TO THE LANDLORD'S SYSTEM, CONTACTOR SHALL OBTAIN WRITTEN CONFI "MATION FROM THE LANDLORD'S FIELD REP' SENTATIVE, THAT ALL TESTING, FLUSHI G, AND PROPER FILLING OF THE TENAN S SYSTEM HAS BEEN COMPLETED IN AI. CORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANT'S SYSTEM IS READY TO BE CONNECTED TO TH LANDLORD'S SYSTEM. GATE VALVES, 2 -1/2 IN RENEWABLE BRONZE SEAT AND RE- PACKABLE UNDER SWING CHECK VALVE, 2 -1/2 IN H AND L RGER: CLASS 125 CAST IRON BODY AND BOLTED CAP, HORIZONTAL SWIN• RENEW BLE BRONZE DISC, FLANGED ENDS AND CAPABLE OF BEING REFITTED WHIG E THE VALVE REMAINS IN THE LINE. e. COMBINATION BALANCING AND SH -0' F VALVES: BELL & GOSSETT CIRCUIT SETTER WITH LOCKING SET POINT. £ • RCUIT SETTER BALANCE WHEEL MUST BE INCLUDED WITH 0 & M MANUAL. TAI. 'I OR GRISWOLD ARE CONSIDERED AS EQUAL. 4. PIPING SPECIALTIES PRESSURE /TEMPERATURE TEST PL TO RECEIVE EITHER A TEMPERAT AND CAPS SHALL BE BRASS WIT 0 TO 200 DEGREES F. STRAINERS - "Y" PATTERN ST AINERS, 12 PSIG, CAST IRON BODY WITH PERFORATED STAINLESS STEE SCREEN, TH' ADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2 -1/2 INCHE AND LARGER. •CREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INC FOR CHILLED OR CONDENSER WATER. PROVIDE WITH BLOWDOWN VALVE WITH H E END FITTING. 5. INSULATION ALL HYDRONIC PIPING F INCLUDING CONDENSER FITTINGS, AND ACCES INCHES, INSULATE WI WITH ALL SERVICE J AND LARGER, INSU INSULATION WITH a. INSTALL CHANGE AND SMALLER: CLASS 150, B NZE WITH THREADED OR SOLD • ZE WEDGE DISC, RISING ST7 RESSURE. BALL VALVES 'E AND LARGER: CLAS• 125 CAST IRON BODY, AND SOLID WEDGE DISC, RISING STEM, FLANGED ENDS, PRESSURE. H AND SMALLE' CLASS 150. CAST BRONZE BODY TM B 62 WITH ORIZONTAL SWING, Y- PATTERN, HAVING TH` ADED OR SOLDERED ENDS. GS PETE'S PLUG) - 1/4 INCH NPT FITTINGS E OR PRESSURE PROBE, 1/8 INCH 0.0. FITTING VALV CORE OF NORDEL, RATED AT 400 PSIG, R CHILLED WATER AND/ ATER UNLESS SPECIFICAL RIES SHALL BE INSULATED. 1 INCH THICK (K =0.23 @ 7 CKET AND VAPOR BARRIER. FO ATE WITH 1 -1/2 INCH THICK (K= L SERVICE JACKET AND VAPOR BA �DY AND UNION BONNET OF R ENDS, INTEGRAL SEAT, SCREWED BONNET AND ACCEPTED AS AN EQUAL R HEATING WATER (NOT Y NOTED OTHERWISE), VALVES, FOR PIPE SIZES UP TO 2 °F) FIBERGLASS INSULATION PIPE SIZES 2 -1/2 INCHES 23 @ 75 °F) FIBERGLASS BIER. b. INSULATION AT A L HANGERS FOR PIPING 2 1/2 INCHE AND LARGER SHALL BE HARD AND NO COMPRESSIBLE. c. ALL INSULATIO SHALL HAVE A FLAME SPREAD RATING 0 NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 5 TO CONFORM WITH THE REQUIRE ENTS OF THE NFPA. d. PROVIDE ZE', ON OR EQUAL INSULATION FITTINGS FOR ALL T 5, ELLS OR SPECIALTY ITTINGS. 6. GENERAL INS ALLATION ATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCIN IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. b. BRANC ES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM 0 45 D REE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES T MAIN'. TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE UP ARD TOWARDS UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. c. SE' MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. N. REFRIG 'ANT PIPING: IPING CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT TEM BETWEEN THE INDOOR FAN UNITS AND OUTDOOR CONDENSING UNITS PLANS TO DETERMINE IF A REFRIGERANT SYSTEM IS REQUIRED. ALL ELBOWS ARE TO BE LONG RADIUS TYPE. SPECIFICATIONS (CONTINUED) AGE AT A COUPLINGS AT MAINS AT A UNITS ABOVE •ITCHED IPING REFER a REFRIGERANT PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBING (AST B88). TUBING SHALL BE CLEAN, CAPPED AND NITROGEN CHARGED. b. ALL FITTINGS AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI B16.22). ALL COPPER TO COPPER JOINTS SHALL BE BRAZED WITH A COPPER-PHOSPHORUS ALLOY AND ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS -5 ALLOY. P. Q. ROOM NAME CUSTOMER SERVICE STORAGE TOILET TOTAL REFRIGERANT PIPING (CONTINUED): INSTALLATION MA UNCONDITIONED BRAZE TOWARD T BROKEN LAS TIME THE SYST BEFORE LEAVING WITH AN INERT GAS SYSTEM IS TIGHT. EVAC CHARGE SYSTEM WITH 25 RETEST SYSTEM. ENERGIZE COMPRESSOR TO ENSURE THAT COMPRESSOR. c. UPON COMPLETION OF TESTING, B . B IS APPLIED, THE PIPING MUST INSPEC LOCAL GOVERNING AUTHORIT AS NECESSA d. INSULATE THE REFRIGER RUBATEX OR ARMSTR RATING OF NOT MO THAN 50 IN AC HOT GAS (LI 4. INSPECTION END OF SECTION 15500 AREA (SQ.FT.) 532 320 237 92 292 1473 JOINTS WITH SILFOS -5 STARTING AT THE INDOOR U OUTDOOR UNIT. THE SEALS ON THE OUTDOOR U. NITROGEN BLEED SHALL BE USED DURING IS OPEN. ALL OPEN LINES SHALL B SITE DURING CONSTRUCTION. P' TO 245 PSIG. REDO LEAKI ATE ENTIRE SYSTEM TO I OF R -22 AND NK CASE L REF SUCTION LINES ANI G 1 INCH THICK PIPE INSU THAN 25 AND A SMOKE DEVE DANCE WITH INDUSTRY STANDARDS. ) LINES OR ANY HOT GAS BYPASS. 0/A PER ASHRAE 62 -99 CFM /SQ.FT. 0.30 0.20 0.15 0.20 TOTAL REQUIRED TOTAL PROVIDED CFM 160 64 36 18 278 280 5 • •, •'r T N AND WORKING SHALL BE LL BRAZING AND ANY APPED AND SEALED SSURE TEST FOR LEAKS JOINTS AND RETEST UNTIL 00 MICRONS OF MERCURY. INERT GAS TO 245 PSI AND ATERS 24 HOURS PRIOR TO STARTING ERANT LIQUID IS OUT OF THE ORE THE REFRIGERANT PIPING INSULATION D BY A REPRESENTATIVE OF THE CONDENSATE LINES WITH TION WITH FLAME SPREAD ED RATING OF NOT MORE 0 NOT INSULATE THE ATIC TO THE NING L THE MS UCTION LINES SHALL HAVE ADEQUATE LIFT TRAPS AND /OR DOUBLE SUC RS TO MEET THE REQUIREMENTS OF FIELD CONDITIONS AND EQUIP ACTURER'S RECOMMENDATIONS. a. CONT' A CTOR MUST PREPARE AND SUBMIT A COMPLETE PIPING SC LOCAL MANUFACTURER REPRESENTATIVE FOR APPROVAL PRIOR TO B . STALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST C- LOCAL REFRESENTATIVE FOR FIELD INSPECTION OF WORK PERFORMED. ALL FOUND TO BE INADEQUATE FOR PROPER PERFORMANCE BY MANUFACTURER REPRESENTATIVE MUST BE CORRECTED. THIS INSPECTION IS PERFORMED AT JAM JUICE'S EXPENSE. 0. LABELS /PIPE MARKERS CONTINUED 1. FURNISH AND INSTALL PIPE IDENTIFICATION MARKERS ON ALL PIPES INSTALLED UNDER THIS CONTRACT. MARKERS SHALL BE A MINIMUM OF 1 -1/2" X 8" AND IDENTIFIED IN ACCORDANCE WITH THE BACKGROUND AND LETTER COLORS ISSUED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). 2. PIPING SHALL BE IDENTIFIED AS FOLLOWS: CHILLED WATER RETURN, CHILLED WATER SUPPLY, CONDENSATE, HOT WATER RETURN, HOT WATER SUPPLY, CONDENSER WATER RETURN, CONDENSER WATER SUPPLY, REFRIGERANT LIQUID, REFRIGERANT SUCTION, AND DIRECTIONAL ARROWS. ALL IDENTIFICATIONS MUST BE VISIBLE AT EQUIPMENT. CURBS FOR SUPPORT 1. THIS CONTRACTOR WILL FURNISH AND INSTALL ALL NECESSARY CURBS REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14" (SHALL COMPLY WITH LOCAL AREA REQUIREMENTS) HIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT UNLESS NOTED OTHERWISE. ALL CURBS MUST BE INSTALLED THAT TOP OF SO CURBS ARE LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. THIS CONTRACTOR MUST RECEIVE JAMBA JUICE'S PROJECT MANAGER'S WRITTEN APPROVAL BEFORE ANY WORK TAKES PLACE. THIS CONTRACTOR IS ALSO RESPONSIBLE FOR ALL SEISMIC, HURRICANE OR OTHER SECURING DEVICES REQUIRED BY LOCAL OR OTHER CODES. TESTING. ADJUSTING, AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO IS A CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING AND BALANCING SHALL BE INCLUDED IN THE BID. HOWEVER, IT WILL BE THE G.C. THAT WILL CONTRACT DIRECTLY WITH THE AIR BALANCING COMPANY. SCHEDULE BALANCING WITH OWNER'S FIELD REPRESENTATIVE. PROVIDE A COPY OF THE CERTIFIED AIR BALANCE REPORT AND CERTIFIED OUTSIDE AIR REPORT TO OWNER PRIOR TO OCCUPANCY. 2. FINAL TESTING, ADJUSTING AND BALANCING REPORT MUST BE COMPLETE AND SUBMITTED WITH FINAL CLOSE -OUT DOCUMENTS TO JAMBA JUICE 1 WEEK PRIOR TO MERCHANDISING DATE. 3. THE HVAC CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL DEVICES, VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION, EXCEPT AS NOTED OTHERWISE. HVAC CONTRACTOR SHALL ALSO INSTALL A NEW SET OF FILTERS ONE DAY PRIOR TO MERCHANDISING. 4. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE BALANCE REPORT. 5. AIR BALANCING CONTRACTOR IS TO CONFIRM OVERRIDE OF MINIMUM OUTSIDE AIR INTAKE UPON CO2 MONITORING CONFIRMATION. FOR CO2 MONITORING CONTACT, SEE AIR BALANCE COVER SHEET E0O.0. 6. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO JAMBA JUICE FOR APPROVAL. THE GENERAL CONTRACTOR SHALL VERIFY THE COMPLETENESS OF THE REPORTS PRIOR TO SUBMITTING TO JAMBA JUICE. SUBMIT ONE COPY OF FINAL APPROVED AIR BALANCE REPORT TO MALL GENERAL MANAGER. 7. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED ON THESE DRAWINGS. ALL SYSTEMS UNABLE TO BE COMPLETELY BALANCED AT THE TIME OF ORIGINAL BALANCE MUST BE BALANCED IN FUTURE AT NO ADDITIONAL EXPENSE TO JAMBA JUICE. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT JAMBA JUICE DEEMS NECESSARY AT NO ADDITIONAL COST TO JAMBA JUICE. OUTSIDE AIR CALCULATION REFER TO OWNER'S SPECIFICATIONS FOR MORE INFORMATION AND COORDINATION WITH OTHER TRADES. 1. IT IS REQUIRED THAT THE MECHANICAL CONTRACTOR MUST VISIT THE JOBSITE TO FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS, PLUMBING LOCATIONS AND ELECTRICAL RUNS. ADDITIONALLY, MECHANICAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS H.V.A.C. UNITS, DUCTWORK, ETC., PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PRE - DETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE OWNER'S FIELD REPRESENTATIVE FOR RESOLUTION. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES AND LANDLORD'S REQUIREMENTS. 3. UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE HEATING, VENTILATING AND AIR CONDITIONING WORK WHICH INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: a. b. c. 4. ALL COMPONENTS AND EQUIPMENT SHALL BE PROVIDED WITH AN EASE OF SERVICE AND MAINTENANCE AS REQUIRED BY CODE AND THE LANDLORD. 5. FURNISH AND INSTALL THERMOSTAT AS SHOWN ON THE PLAN AT A MIN. OF 3FT - MAX. OF 4FT A.F.F. (VERIFY LOCAL CODES). COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE. PROVIDE CONTROL WIRING AND CONTROLS AS REQUIRED. CONTRACTOR SHALL PROVIDE PRODUCT DATA SUBMITTALS FOR ALL EQUIPMENT AND DEVICES TO THE OWNER FOR HIS REVIEW AND /OR APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 7- LANDLORD SHALL PROVIDE A/C UNIT FILTER REPLACEMENT AFTER CONSTRUCTION IS COMPLETE. 8. INSTALLATION ACCEPTANCE MAY BE SUBJECT TO CONSTRUCTION REVIEW BY AN INDEPENDENT AIR CONDITIONING FIRM. 9. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL TEST, START-UP AND BALANCE THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED TO INSURE PROPER WORKING ORDER. ADJUST AIR QUANTITIES TO WITHIN 10% OF DESIGN VALUES. SUBMIT A COPY OF AIR BALANCE REPORT BY AN OUTSIDE CERTIFIED AIR BALANCE TECHNICIAN, CERTIFIED BY THE AABC (ASSOCIATED AIR BALANCE COUNCIL) OR NEBB (NATIONAL ENVIRONMENTAL BALANCING BUREAU), AND A COPY OF REPRODUCIBLE SET OF THE "AS- BUILT" DRAWINGS TO THE OWNER AND TO THE LANDLORD FOR THE RECORDS AND TO THE DESIGN ENGINEER'S OFFICE PRECEDENT TO FINAL PAYMENT. NOTE: SMOKE DETECTORS INSTALLED WITHIN AIR MOVING SYSTEMS SHALL BE FULLY TESTED TO THE SATISFACTION OF THE LOCAL FIRE DEPARTMENT. TESTING SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL FIRE DEPARTMENT. SYMBOL 0 0 120 -0 6 THERMOSTAT CONSTRUCTION NOTES FURNISH AND INSTALL 4 "0, 24GA. GALVANIZED STEEL EXHAUST DUCT FROM DRYER (FIELD VERIFY EXACT SIZE AND LOCATION, MINIMUM OF 4 "). REMOVE ALL EXISTING DUCTWORK AND EQUIPMENT NOT TO BE RE -USED AND DISPOSE OF SAME OFF LANDLORD'S PREMISES. FURNISH AND INSTALL ALL NEW DUCTWORK INCLUDING GRILLES, DIFFUSERS AND DAMPERS IN ACCORDANCE WITH S.M.A.C.N.A. CURRENT STANDARDS AND THE LANDLORD'S REQUIREMENTS - (SHOWN ON PLANS AS SOLID LINES). 1. ALL MATERIAL SHALL BE NEW AND OF COMMERCIAL GRADE, AND BEAR UNDERWRITER'S AND UNION LABELS WHERE SUCH LABELING APPLIES. 2. ALL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET METAL OR PRE-INSULATED ALUMINUM CORRUGATED FLEXIBLE DUCT IN ACCORDANCE WITH THE STANDARD OF AMERICAN SOCIETY, REFRIGERATION AND AIR CONDITIONING ENGINEERS NATIONAL ASSOCIATION, FOR LOW PRESSURE, LOW VELOCITY DUCTWORK OR AS PER LOCAL CODE. 3. BRANCHES FROM MAIN LOW VELOCITY TRUNK DUCTWORK SHALL BE FURNISHED WITH SPLITTERS, DAMPERS OR SIMILAR BALANCING DEVICES IN ACCORDANCE WITH THE STANDARDS OF THE ASSOCIATED AIR BALANCING COUNCIL. (FIRE DAMPERS SHOULD BE PROVIDED AS REQUIRED BY ANY APPLICABLE CODES AND /OR JURISDICTIONAL AUTHORITIES). 4. ALL DUCTS FOR FINAL CONNECTION TO DIFFUSER SHALL BE CLASS 1 U.L. LISTED (SL 181) FLEXIBLE AIR DUCT NOT TO EXCEED 5' -O" IN LENGTH (THERMAFLEX, GLASSFLEX OR APPROVED EQUAL). 5 - SUPPLY DUCTWORK SHALL BE INSULATED WITH ONE (1) INCH THICK MINIMUM BLANKET INSULATION WITH VAPOR BARRIER. ACOUSTICAL LINER MAY BE PROVIDED AS REQUIRED PER NFPA STANDARDS, I.R.I. REQUIREMENT AND UL RATED. (EQUAL TO MANVILLE FIBERGLASS INSULATION) REMOTE SENSOR SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE ROUND DUCT HVAC SYMBOLS DESCRIPTION RECTANGULAR DUCT (FIRST FIGURE IS SIDE SHOWN) SMOKE DETECTOR AUTOMATIC BACKDRAFT DAMPER UNDERCUT DOOR 1" FLEXIBLE DUCTWORK. 5' -0" MAX. MANUAL BALANCING DAMPER DIRECTION OF AIR FLOW NEW TO EXISTING CONNECTION C 7. 8 9 10 GENERAL NOTES 1 THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT MECHANICAL PLAN CHECK DIVISION AND THAT DIVISION'S STAMP APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 2. COORDINATE ALL WORK WITH ARCHITECTURAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. IS TO BE IN CONTACT WITH ANY EQUIPMENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. 4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 5. REFER TO THE MECHANICAL SHEETS FOR DETAILS, SCHEDULES AND SPECIFICATIONS. 6. CONTRACTOR SHALL PROVIDE CUT SHEETS TO JAMBA JUICE FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. HVAC CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY SMOKE EVACUATION SYSTEM IN USE AT THE MALL AT THE TIME OF THE BID. IF THE SAID SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE MECHANICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO A LANDLORD'S SMOKE EVACUATION SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE ITEM FOR THE SMOKE EVACUATION SYSTEM AT THE TIME OF THE BID. 8. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE /MAINTENANCE EASE. 9. PRIOR TO STARTUP OF HVAC EQUIPMENT, MECHANICAL CONTRACTOR WILL CONFIRM WITH HVAC MANUFACTURER THAT CORRECT POWER IS PROVIDED TO JAMBA JUICE PROVIDED HVAC UNITS AND HAS BEEN TURNED ON A MINIMUM OF 24 HOURS. JAMBA JUICE RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD JAMBA JUICE FIND CORRECTIVE WORK TO BE NECESSARY, THEY WILL NOTIFY CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE CONTRACTOR. 10. IF WORK IS REQUIRED BY JAMBA JUICE IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY JAMBA JUICE TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE CONTRACTOR CANNOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE THE OWNER MAY, AT HIS DISCRETION TAKE OVER SUCH WORK AND BACKCHARGE THE CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND /OR ADHERENCE TO PLANS AND SPECIFICATIONS. 11. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. HVAC LOAD CALCULATION DESIGN CONDITIONS! OUTDOOR INDOOR SUMMER DRY BULB SUMMER WET BULB HUMIDITY RATIO WINTER DRY BULB SUMMER DESIGN MONTH 85 75 68 62,5 76 65 22 70 JUNE DAILY SWING DIFFERENCE 10 5, 5 11 48 19 DATE 7/19/200JOB # 070288 CLIENT JAMBA JUICE ADDRESS SOUTHCENTER SQUARE CITY & STATE TUKWILA, WA ASHRAE CITY SEATTLE CO ALTITUDE 14 LATITUDE 47 LEASE AREA 1473 SO. FT. C ITEM DIR. CLTD LAT CORR K O N ROOF FLAT 78 2 1 D WALL NORTH 10 1 1 U WALL SOUTH 17 3 1 C WALL EAST 29 2 1 T WALL WEST 14 2 1 GLASS ALL 14 2 1 ITEM DIR. SC S 0 GLASS NORTH 0.39 GLASS SOUTH 0.39 A GLASS EAST 0.39 R GLASS WEST 0.39 L TYPE I G FLUORESCENTS H FLUORESCENTS T INCANDESCENTS S INCANDESCENTS E ITEM Q U EQUIP. @.5W /SF I HVAC FAN HP P EQUIPMENT PEOPLE 0 AREA X CFM /SF A 1473 0, 19 1473 0. 19 COMBINED DUCT LOSS, SHGF CLF AREA 46 96 215 142 WATTS 1204 169 700 550 VALUE 0 1. 5 18000 X 0.82 0 0.64 90 0.2 0 0.76 220 0. 5 1 0.25 100 SG, FT, /PERSON IAT ODA CORR TEMP CORR 3 -9.5 3 -9.5 3 -9.5 3 -9.5 3 -9.5 3 -9.5 X BTU /X FAC 3. 41 3, 41 3, 41 3. 41 X MULTI = 3. 41 2545 3. 41 0 3818 15345 1. 1 1. 1 1 1 CORR U CLTD VAL 74 0, 05 5 0. 14 0. 05 25 0. 05 10 0. 05 10 0, 80 SUBTOTALS NOTES INFILTRATION, WARM -UP AND SAFETY MARGIN @ 5% 5 AWNING 5'-0' AWNING X % TO SPACE 0. 75 1. 00 1. 00 0. 75 BOR ASHRAE BTUH 250 BTUH /PERSON BF X TEMP DIFF X FACTOR 0, 1 10 1, 10 1. 0 48 1.10 AREA 1473 0 70 0 75 310 RECESS SURF SURF RECESS BTUH COOLING 5413 0 47 0 36 2356 7852 0 2157 0 9260 3387 634 2387 1407 0 3818 15345 3683 308 2512 BTUH HEATING 3535 0 168 a 180 11904 15787 14777 L A T E N T 0 T H E R OUTDOOR AIR PEOPLE EQUIPMENT INFILTRATION ITEM DUCT GAINS OUTDOOR AIR, SENSIBLE OUTDOOR AIR, LATENT INFILTRATION ROOM SENSIBLE HEAT GAIN (LOSS) = 280 CFM 100 SQ.FT. /PERSON @ 200 BTUH /PERSON 9000 0. 25 3.41 7672.5 210 CFM ROOM LATENT HEAT GAIN = QTY FACTOR FACTOR 6397 0.25 1.00 280 10 0.90 280 11 0,90 210 CFM ALTITUDE CORRECTED FACTOR or 'U' VALUE 0.20 1, 10 0. 68 55026 209 2946 7673 1617 12445 320 2771 1884 2279 30564 10937 T 0 T A L S ROOM SENSIBLE LOAD LATENT LOAD SENSIBLE HEAT RATIO MINIMUM CFM COIL INLET (DB /WB) 58117 14329 0.80 2536 76 63 GRAND TOTAL LOAD (BTUH) 72446 NOMINAL TONS REQUIRED RECEIVED 6, 0 HEATING (BTUH) CITY OF TUKWILA ELECTRIC HEATING (KW) Sri' 0 d ?nO7 PERMIT CENTER 41501 12. 15 A A A A A A Issue Date Drawn By Appv'd By Revisions Date J5.2.2 VERSION .1 01 )) .7 0 gimm JLP dp DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817 -251 -8411 DAR Description 8/21/07 By "o N. 0 05 -10 -07 5.2.2 Mechanical Specs. & Calculations M -002 M0 7- l 83/4 DIFFUSERS, GRILLES AND REGISTERS MARK SERVICE LOCATION CLG. TYPE MANUFAC. CATALOG NUMBER REMARKS D -1 SUPPLY CEILING AC. TILE TITUS PAS XX 24x24 3 26 D -75 SEE PLAN FOR NECK SIZE D -2 SUPPLY CEILING GYP TITUS PAS XX 12x12 1 26 D-75 SEE PLAN FOR NECK SIZE D-3 SUPPLY CEILING GYP TITUS TBDI -30 (2x1" SLOTS, 4' LONG) PROVIDE TRIM AS REQUIRED G -1 RETURN CEILING AC. TILE TITUS PAR 22x22 24x24 3 26 AG-95 0.50 C 2 RELIEF 1b', ^,LL AC. TILE TITUS 12 ")(C" Z5 zrL DH078N10C2 890 LBS - -/11.5 80% 11.9 - 1 GO ROOF TOP UNITS MARK CAPACITY IN TONS COOLING CAP. (MBH) COMPR. KW HEATING CAP. (MBH) CFM CFM 0/A EXT. S.P. FAN HP ELECTRICAL MANUFACTURER MODEL NUMBER WEIGHT EFFICIENCY TOTAL SENSIBLE INPUT OUTPUT VOLTS PH MCA MOCP r SEER /EER AFUE IPLV V07 6.5 79.8 61.4 3.2 120 96 2600 280 0.50 1.5 208 3 35.0 40 YORK DH078N10C2 890 LBS - -/11.5 80% 11.9 THERMOSTAT AND SENSORS MARK LOCATION MANUFACTURER MODEL NUMBER REMARKS V05 BACK AREA LIGHTSTAT TMD— AVU —RS* FURNISHED AND INSTALLED BY G.C. V06 SALES LIGHTSTAT TMD — REMOTE SENSOR* MOUNT AT 60" A.F.F. EXHAUST FANS MARK LOCATION SERVICE CFM EXT. S.P. (IN W G S ONES MOTOR DATA RPM MFR. REMARKS HP VOLTS PH CYC. V09 CEILING TOILET 100 0.25 1.1 -- 120 1 60 -- BROAN MODEL L100 L07* J1 I r f LCNUfVI L 2 L 2G 1 1 GO CRCCPJI ICCIC 1v CL 300 CFM 12" ID -3 500 CFM 12 "0 ID -1 MECHANICAL GENERAL NOTES A "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. B WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSERS, TOILETS, ETC.) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDED RELAMPING ALL LIGHTS REUSED. C EXISTING CONDITIONS ARE BASED ON "AS— BUILT" DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. D CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION /CONSTRUCTION OF NEW WORK. E GENERAL CONTRACTOR SHALL COORDINATE RESPONSIBILITY BETWEEN MECHANICAL AND ELECTRICAL CONTRACTOR, ALL LINE VOLTAGE AND LOW VOLTAGE REQUIREMENTS FOR A COMPLETE PROJECT F COORDINATE DUCT ROUTING AND HEIGHTS WITH GENERAL CONTRACTOR. VERIFY ALL CLEARANCES BEFORE STARTING WORK. G THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT CRITERIA MANUAL. TENANT CRITERIA MANUAL REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH LANDLORD REQUIREMENTS AT NO EXTRA COST TO THE TENANT. H NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. I ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. J CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER FOR RESOLUTION. K ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. L A FREE AREA FOR MAINTENANCE ACCESS AROUND THE HVAC EQUIPMENT SHALL BE PROVIDED. VARIFY CLEARANCE WITH LOCAL CODE AND MANUFACTURERS REQUIERED SERVICE ACCESS. M THE MECHANICAL CONTRACTOR SHALL INSPECT AND RUN TEST ALL EXISTING UNITS AT THE START OF CONSTRUCTION AND INFORM THE OWNER'S REPRESENTATIVE OF ANY NECESSARY REPAIRS FOR APPROVAL IN A TIMELY MANNER TO NOT DELAY THE STORE OPENING DATE. N ALTER MEDIA SHALL BE UTILIZED TO PROTECT ALL RETURN OPENINGS DURING CONSTRUCTION. O FLEX DUCTS SHALL BE LIMITED TO A MAX. LENGTH OF 5' -0" PER BRANCH RUNOUT. P THE GENERAL CONTRACTOR AND MECHANICAL SUB — CONTRACTOR SHALL VERIFY AND INCLUDE IN THEIR FINAL BID ALL LIFE SAFETY, SMOKE /FIRE ALARM SYSTEMS NEEDED TO BRING TENENTS SPACE COMPATIBLE WITH THE LANDLORD'S SYSTEM., AND CURRENT WITH LOCAL AND STATE CODES. FAILURE TO DO SO SHALL RESULT IN NO EXPENSE TO THE TENANT. NECK AND RUNOUT SIZE. (SUPPLY TRANSITION AS REQUIRED TO CONNECT BRANCH DUCT AS SHOWN) CUBIC FEET PER MINUTE DIFFUSER /GRILLE TAG 1 E31 V e. m 50 CFM 6 "G JD 2 ) . 400 CFM 12"0 I D —1 12' o, 400 CFM 12 "0 ID - COOLING CAPACITIES BASED ON ARI STANDARD 210/240 -89: 80° F DB/ 67° F WB INDOOR ENTERING AIR TEMPERATURE, 95° F DB AIR ENTERING OUTDOOR FAN. SCHEDULED UNIT CFM MAY DIFFER FROM ARI STANDARD CFM. 1. CONDENSING COILS SHALL BE PROTECTED WITH FACTORY APPLIED COIL COATING. 2. UNIT SHALL BE FURNISHED WITH DIFFERENTIAL ENTHALPY ECONOMIZER. CAPABLE OF 100% OUTSIDE AIR DIFFUSER /GRILLE TYPE 3. UNIT TO BE FURNISHED WITH TWO SET OF STANDARD FILTERS. CONTRACTOR TO REPLACE FILTERS PRIOR TO TURNING STORE OVER TO TENANT. (REFER TO SCHEDULE) 4. UNIT SHALL INCLUDE A FULL PERIMETER ROOF CURB. 5. ALL ROOF WORK INVOLVED WITH SETTING OF THE ROOF CURB AND UNIT SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR. LANDLORD SHALL PROVIDE ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT RTU, PER LANDLORD'S REQUIREMENTS. 6. LANDLORD TO SUBMIT MANUFACTURER'S INSTALLATION INSTRUCTIONS TO BUILDING DEPARTMENT. 7. FURNISH UNIT WITH MFG OPTIONAL POWER EXHAUST IF AVAILABLE. * FURNISH WITH AUTOMATIC BACKDRAFT DAMPER; INTERLOCK WITH LIGHT SWITCH. r 0 DI IVO7 1 G -1 2 —WAY 300 CFM 1O "0 D -1 2— WAY C * DO NOT LOCATE UNDER NIGHT LIGHT FIXTURE. ALSO, DO NOT INSTALL ABOVE ANY HEAT GENERATING EQUIPMENT. MECHANICAL PLAN SCALE: 1/4" = 1' -0" rj MECHANICAL KEYED NOTES NORTH RECEIVED CITY OF TUKWILA S.p 0 i 7nrt7 PERMIT CENTER 0 EXISTING ROOFTOP UNIT BY LANDLORD, CONTRACTOR SHALL VERIFY LOCATION, ORIENTATION, DIMENSIONS AND EXISTING CONDITIONS. CONTRACTOR SHALL ADJUST DUCTWORK AS REQUIRED. SET UNIT TO DELIVER AIR QUANTITY SPECIFIED. O ROUTE 6 EXHAUST DUCT FROM EXHAUST FAN TO 8 "0 DUCT THRU ROOF (FIELD VERIFY). FURNISH AND INSTALL WITH BACKDRAFT DAMPER, ROOF CAP AND ACCESSORIES AS REQUIRED. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. EXHAUST VENT TO BE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. a3 UNDERCUT DOOR 1". COORDINATE WITH THE OWNER'S FIELD REPRESENTATIVE. O CONTRACTOR TO FURNISH AND INSTALL RIGID 4 "0 DRYER EXHAUST DUCT FROM DRYER UP THRU ROOF WITH RAIN CAP. THE RIGID MOISTURE EXHAUST DUCT SHALL NOT EXCEED 15 FEET INCLUDING 2 -90' ELBOWS OR AS ALLOWED BY DRYER MANUFACTURER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. EXHAUST VENT TO BE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. ® DUCT SMOKE DETECTOR ON SUPPLY SIDE DUCT AND SHUTDOWN RELAY SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. ALL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. Q FLU VENT PIPE THRU ROOF FROM WATER HEATER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. LOCATE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. SEE DETAIL 2/M -501. DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817- 410 -2858 FAX 817 -251 -8411 A A A Issue Date Drawn By Appv'd By Revisions Date J5 -2.2 VERSION NOT t8 L+ dp co co r co O � w � J 8/21/07 J LP DAR Description M -70 0 ce r By Mechanical Plan 0 05 -10 -07 5.2.2 WHERE REQUIRED, PROVIDE VOLUME DAMPER WITH ROUND DUCT STRAP OR ANGLE TRAPEZE HANGERS LOCKING QUADRANT. PROVIDE WITH 3" EXTENDED SHAFT DAMPER HANDLE TO BE AND HANDLE INSTALLED MAXIMUM OF 3' -0" ABOVE CEILING. SHT. MIT_. ELBOW REQUIRED SECURELY TAPE VINYL FLEX DUCT ROD —g.-- 11111111 / \ ROOF JOIST 1 TO SHT. MTL. W/ MIN. OF (2) CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FLEX DUCT INSULATION & VINYL TO SHT. TABLE 4 -1 - RECTANGULAR DUCT HANGERS - MINIMUM SIZE MAX. HALF OF DUCT PERIMETER PAIR AT 10' SPACING PAIR AT 8' SPACING PAIR AT 5' SPACING PAIR AT 4' SPACING MTL. TAPE INSULATION TO DUCT TO A STRAP WIRE /ROD STRAP WIRE/ROD, STRAP WIRE /ROD STRAP WIRE /ROD IalI �!j FORM A GOOD SEAL P = 30 2 1" x 22 go. g 10 ga. (•135') 1" x 22 ga. 10 ga. (•135') 1" x 22 go. 12 g (•106) 1" x 22 ga. 12 ga. (•106 ° ) SCREWS SIZE BOLT(S) FOR LOAD STRAP HANGERS 18" LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO rr _r 8" LONG SHT. MTL. SECTION IDENTIFY LOCATION P 2 = 72" 1" x 18 go. 3/8" 1" x 20 go. 1/4" 1" x 22 ga. 1/4' 1" x 22 ga. 1/4" SECURED TO DIFFUSER COLLAR W/ MIN. (3) SHT. M. SCREWS, DUCT TAPE AND MASTIC. - SHEET MTL. DUCT HANGER - HANGER UNLESS FOOT OF P = 96" 1" x 16 ga. 3/8 1" x 18 go. 3/8" 1" x 20 go. 3/8" 1" x 22 go. 1/4" INSULATED FLEXIBLE CONNECTION ") TRANSITION FROM DUCT STRAPS STRAP IS PLACED UNDER A BOTTOM REINFORCEMEN r SCREWS MAY BE OMITTED IF MANGER LOOPS (MAX. 5' -0 SIZE TO DIFFUSER NECK FIRE DAMPER WHERE , SIZE AS NECESSARY P = 120 2 1 1/2" x 16 ga. 1/2" 1" x 16 ga. 3/8" 1" x 18 ga. 3/8" 1" x 20 go. 1/4" 60" MAX. INDICATED ON PLANS. •111111 THERMAL INSULATING BLANKET �J 2 = 168 1/2" x 16 ga. ii 1/2" 1 1/2" x 16 ga. 1/2" 1' x 16 ga. 3/8' 1' x 18 ga. 3/8" �REQUIRED FOR FIRE RATED CEILINGS ONLY. P 192" 2 = 192 - 1/2" 1 1/2" x 16 ga. 1/2" 1' x 16 ga. 3/8" 1° x 18 ga. 3/8' SPIRAL DUCT HA \ 1 \GER INSULATION SPIRAL DUCT DETAIL CEILING MOUNTING LAY IN C E LING MOUNTING SUPPLY AIR DIFFUSER (BORDER TYPE 3). FOR GYP. CEILING P 193 "up SPECIAL ANALYSIS REQUIRED �� 1 "� MIN. —= 2 ---- -I (LAY -IN FRAME) 10 CEILI\G DIFFUSER vOU \TI APPLICATION USE SURFACE MOUNTED DIFFUSER (BORDER TYPE 1). \G DETAIL NOTE: INFORMATION REFER TO EDITION OF SMACNA FOR ADDITIONAL THE LATEST 8 RECTANGULAR DUCT HA \GER ATTACHVE \T DETAIL SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. A B ALTERNATE MAX NO 90 SUPPLY END DIFFUSER DIFFUSER D, TAP LOCATION. FLEX DUCT LENGTH = 5' -0 ". TURNS GREATER THAN (1) ° NOTES: MECHANICAL EQUIPMENT. WHICH EXCEED 9" SQUARE AT LLS (NOT RIBBED OR DEFORME► REBAR). OR PEEN NUT TO BOLT. 1) 1. COORDIN • BURGLAR BARS WITH 2. INSTALL BURS AR BARS AT OPENINGS AND /OR ROOF 0 INGS. 3. #6 BARS TO HAVE MOOTH SURFACE 4. AFTER BARS ARE INS LED WELD o N` • VENT TOP PLASTIC CEMENT p STORM COLLAR ROOF FLASHING TURN PERMITTED. DUCT ROOF AND INSULATION DECK 1/4° OF DUCT 1/4 — A LO q — 15' OR LESS B AIR f— FLOW INSULATE VENT PIPE 15' OR LESS r . AIR �� ._ — ; FLEX DUCT -- - ,I_ =_ _5_1 -- I #6 CROSS BARS © 6" ON CENTER (5 MAX TRANSFORMATION EXPANSION CONTRACTION I....... ;:: . Ilki, D CEILING D LENGTH) NOTE: ": _- •,.; -,_. ° r =` _r' a `. - _� _.. o• ^: r I PATCH AND REPAIR ROOF AS NECESSARY TO MATCH (E) COORDINATE WITH LANDLORD'S ROOFING CONTRACTOR, TYP. TO MAINTAIN ROOF WARANTY. , #6 BARS 6" ON CENTER 4 X 2 -1 /2' F.B. CT C0\ & RECTA \G \ ECTI O\ VANES TURNING TURNING VANE x 2` � ° © 9. BURGLAR BARS F ME -- ATTACH TO STIR TURAL FRAMING WITH 2" DIAMETER M.B. AT 8' ON CENTER - MINIMU 2 M.B. EACH SIDE OF BA ' DUCT LI NING DETAIL GAS APPLIA \CE UE\ SEF. I c 2 . 17 F !' _ ���� . :. LE 4 6 `' • • . . T L L ` 4 , c L 0 THREE TURNING G VANES 2/3D 90' ELBOW D SCALE: N.T.S. SCALE: N.T. SCALE: N.T.S. 45 ELBOW SIMILAR NO THROAT RADIUS SHORT RADIUS FULL RADIUS #10 2" SHT. ETAL • :Y :.• • • y • ' .••" • + •. •.: 1••:,'';' -11 -i .•'• ,: ..;:111111111 .r..:•.:.,�' 1 1111 1 1 11 X y • • - * :,• l lll ., i • i • i 11 • - .'1 •I•.• 11 • i _ "1111' • Y � „ = PIPE OR CONDUIT REDWOOD ON CENTER GALV. METAL SECURED WITH ,• 1111111111 11111111111 f 1 111111 7 ^•: '•;:•: • .�. ` i v y " INVERTED BITUMEN W/ MASTIC BLOCKING AT 6' -0" MAXIMUM FASTENER ::.SCEWS •' • • ~• fl. + ,111111.,•. .�; > : y,•• -•. _. u � .. " • MODIFIED CAP SHEET SET CEMENT CURB MOUNTED : - UNIT) WS ( ER NEOP NE GASKET FA• ORY CURB TURN ROOFING TO EXTEND UNDER CURB RET URN TO FULLY COVER WOOD NAILER. • z nd CAP STORM COLLA FL ASHING o_z _ O I n cr A/C UNIT TURN VANES SUPPLY OR RETURN WYE : U r r o- z z t� LEVELING OF CURB BY G.C. (RECTANGULAR DUCT) 1 1 , ,, �r Q x ROOF ..'.un r�rulTH/li FACTORY CURB ~ �,� ... 1Vi _ �U ^_ ..III, A G.C. p I1I IFf' ► RIGID INSULATION INSULATION I . ■ ,... L.A INSET ��_ /H� : ■ ... PROTECTION) �ry �.11 - - -- -- � BY STRIP BY FOR KICK a 0 BY G. C_ / ROOF O J s) p Q p1 r- I� D -. EXH. DUCT v 3 3/4 D / 90 ELBOW TAKE -OFF t �.� NOTE: RETURN AIR BRANCH USE ONLY IN AREAS FULL RADIUS ELBOW 14" HIGH MIN. PATCH AND REPAIR ROOF AS NECESSARY TO MATCH (E) COORDINATE WITH LANDLORD'S ROOFING CONTRACTOR, TYP. TO MAINTAIN ROOF WARANTY. FITTING WHERE SPACE IS LIMITED TAKE -OFF DUCT THRU ROOF I ROOFING DUCTWOR< DETAILS NOTE: PATC1 AS NECESS - REPAIR MATCH (E) COORDIN • 'r WITH LANDLORD'S Rs� INC CONTRACTOR, ' TO MAINTAIN ROOF WA NTY. FROM RESTROOM 6 EXHAUST AIR DUCT DETAIL NOTE: (E) BUILT -UP ROOFING _ VERIFY IN FIELD RECEIVED CITY OF TUKWILA Sl:p 0 ; ' PATCH AND REPAIR ROOF AS NECESSARY TO MATCH (E) COORDINATE WITH LANDLORD'S ROOFING CONTRACTOR, TYP. ROOFING CONTRACTOR, TO MAINTAIN ROOF WARANTY. •TU PAC CURB ASSEVBLY <AGE WITH DETAIL PERMIT CENTER PIPE SUPPORT BLOC�I \G 9 SCALE: N. SCALE: N.T.S. SCALE: N. SCALE: N.T.S. F E D C B A 2 3 4 5 6 7 8 9 A Issue Date Drawn By Appv'd By Revisions Date A A A A A J5.2.2 VERSION qcik dp DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817- 251 -8411 co CO Description M -501 8/21 /07 J LP DAR ti (-) uJ a 1.. By c •a n ao co N O ti 0 05 -10 -07 5.2.2 Mechanical Details 0 NOT 1s1+ 1 2 3 4 5 E22 ) M5 CV ct ow CV CC o w c 7• GENERAL NOTES 111,B -6,8 II (30/2, #10) M4 B -2,4 O (40/2, #8) A "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E. EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED, IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL. CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. B WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSERS, TOILETS, ETC.) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDED RELAMPING ALL LIGHTS REUSED. C REFER TO MECHANICAL DRAWINGS FOR EXACT SIZE, LOCATION, AND ELECTRICAL REQUIREMENTS FOR ALL MOTORS AND MECHANICAL EQUIPMENT. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. D ALL NEW POWER AND LIGHTING CONDUITS ON THIS PROJECT SHALL INCLUDE AN INSULATED GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS NOTED OR PER NEC WHERE NOT NOTED. THIS GROUNDING CONDUCTOR SHALL BE PROVIDED REGARDLESS OF THE TYPE OF CONDUIT USED. E EXISTING CONDITIONS SHOWN ARE BASED ON AS—BUILT DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. M1 0 NOTE: ROOFTOP UNIT IS PROVIDED AND INSTALLED BY LANDLORD UNDER LANDLORD'S WORK. LANDLORD'S CONTRACTOR SHALL COORDINATE FINAL LOCATION WITH LANDLORD'S STRUCTURAL ENGINEER. LANDLORD'S CONTRACTOR SHALL PROVIDE ANY ADDITIONAL STRUCTURAL BRACING REQUIRED. EXISTING 60 /NF /3 NEMA 3R A- 37,39,41 ( # A -35 MECHANICAL KEYED NOTES M1 ROUTE 8 "0 EXHAUST DUCT THRU ROOF (FIELD VERIFY). FURNISH AND INSTALL WITH BACKDRAFT DAMPER, ROOF CAP AND ACCESSORIES AS REQUIERED. M2 OUTSIDE AIR INTAKE TO BE A MINIMUM OF 10' -0" FROM ANY VENT OR EXHAUST OPENING. M3 CONTRACTOR TO FURNISH AND INSTALL RIGID 4 "o DRYER EXHAUST DUCT FROM DRYER UP THRU ROOF WITH RAIN CAP. THE RIGID MOISTURE EXHAUST DUCT SHALL NOT EXCEED 15 FEET INCLUDING 2 -90° ELBOWS OR AS ALLOWED BY DRYER MANUFACTURER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. EXHAUST VENT TO BE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. 0 FLU VENT PIPE THRU ROOF FROM WATER HEATER. ALL ROOFING WORK SHALL BE DONE BY THE LANDLORD'S ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. LOCATE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. SEE DETAIL 2/M -501. 0 WALK —IN COOLER AND FREEZER CONDENSING UNITS MOUNTED ON ROOF. VERIFY REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION. 8 9 10 M.E.P. ROOF PLAN SCALE: 1 /4" = 1' -0" SEP 1 8 1 sty Of Tbk vii,: ELECTRICAL KEYED NOTES NORTH E1 EXISTING ROOFTOP UNIT BY LANDLORD. CONTRACTOR SHALL VERIFY LOCATION, ORIENTATION, DIMENSIONS AND EXISTING CONDITIONS. CONTRACTOR SHALL ADJUST DUCTWORK AS REQUIRED. SET UNIT TO DELIVER AIR QUANTITY SPECIFIED. E2 LANDLORD SHALL FURNISH, INSTALL AND WIRE COMPLETE DUCT SMOKE DETECTOR AND ASSOCIATED AUDIBLE /VISUAL NOTIFICATION AS REQUIRED BY NFPA 90A. PROVIDE AUDIBLE /VISUAL ALARM AND TEST/ RESET SWITCH ABOVE CASH REGISTER LOCATION. DETECTION SYSTEM SHALL BE AS MANUFACTURED BY EDWARDS OR APPROVED EQUAL. E3 ROUTE CIRCUIT WIRING TO FREEZER EVAPORATOR BELOW. REFER TO SHEET E -102 FOR CONTINUATION. PLUMBING KEYED NOTES 0 3" VENT THROUGH ROOF. SEE SHEET P -102 FOR CONTINUATION. VENT SHALL BE A MINIMUM OF 10' -0" FROM ANY FRESH AIR INTAKE. P2 EXISTING 1" CONDENSATE TO NEAREST CODE APPROVED DISPOSAL SITE. VERIFY LOCATION IN FIELD. () EXISTING 1" GAS PIPING DOWN TO FLOOR BELOW. SEE SHEET P -103 FOR RECEIVED CONTINUATION. CITY OF TUKWILi+ Se_ 0 PERMIT CENTER A A A A MO7 [8 0 ), Issue Date Drawn By Appv'd By Revisions Date J5.2.2 VERSION JLP dp DON PENN CONSULTING ENGINEER 635 WESTPORT PKWY. SUITE 300 GRAPEVINE, TEXAS 76051 817 -410 -2858 FAX 817 -251 -8411 CO cc 0) J 8/21 /07 DAR Description -0 0 0 a a c ra 0 0 By 0 •a n N 0 ti w z I- 0 W fY M.E.P. Roof Plan MEP -101 w •0 n on 0 • 05 -10 -07 5.2.2