HomeMy WebLinkAboutPermit M07-192 - GROUP HEALTH COOPERATIVEGROUP HEALTH 12400 EAST MARGINAL WAY S M07 -192 Parcel No.: 7340600480 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 12400 EAST MARGINAL WY S TUKW Contact Person: Name: CHRIS WRIGHT Address: 19015 36 AV W, STE A , LYNNWOOD WA Contractor: Name: P S R Address: PO BOX 27073 LAKE CITY STATION , SEATTLE WA Contractor License No: PSR * * * *936JP DESCRIPTION OF WORK: ADDING (2) FANS AND RELOCATING (15) COMPUTER ROOM AIR CONDFFIONING UNITS. ASSOCIATED PIPING AND CONTROLS. Value of Mechanical: 100,000.00 Type of Fire Protection: City Tukwila GROUP HEALTH 12400 EAST MARGINAL WY S , TUKWILA WA ANNE ARUNDEL APARTMENTS LLC 10 W MARKET -1200 MARKET TOWE , INDIANAPOLIS IN Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Fees Collected: $998.00 International Mechanical Code Edition: 2006 EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 13 0 0 0 2 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 774 -3829 Phone: 206 367 -2500 Expiration Date: 12/31/2008 M07 -192 10/02/2007 03/05/2008 Boiler Compressor: 0 - 3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -192 Printed: 10 -02 -2007 Permit Center Authorized Signature: Signatur doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction f work. I am authorized to sign and obtain this mechanical permit. a-lr._e /� ( Permit Number: M07 -192 Issue Date: 10/02/2007 Permit Expires On: 03/05/2008 Date: / col / Date: /a/z-A7 Print Name: ' J / 1-1` This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -192 Printed: 10 -02 -2007 Parcel No.: 7340600480 Address: 12400 EAST MARGINAL WY S TUKW Suite No: Tenant: GROUP HEALTH 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -192 Status: ISSUED Applied Date: 09/07/2007 Issue Date: 10/02/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be doc: Cond -10/06 M07 -192 Printed: 10-02 -2007 Vr City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 22: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 23: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 26: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 27: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -192 Printed: 10 -02 -2007 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: 1Q61 L .j /4 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signatur .�✓ - ' mss; Date: irk/ 4 7 M07 -192 Printed: 10 -02 -2007 I CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Name: 04-4.15 J W Q I6*t E -Mail Address: e 4 eAck wr e (S:›4 Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: 014 ( Q.kG7 t44 E -Mail Address: G k� QV v e eve ✓ic33%a QMpplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. Mechanical Permit No. ' 112— Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: / 4 - '''CX/0 0 Site Address: 124 E. t' L NSA (.. t NA-1 ' Suite Number: KV/\ Floor: Tenant Name: 611QO New Tenant: ❑ Yes Property Owners Name: aV0.06 AC ` A Mailing Address: 1 Z5DI E • mk,e6 Loki S A- -1 'TUY-k11Ui4 144 `i81 Off' State Zip City CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 4ZS -"]7 58 Mailing Address: 1'1015 3444m Ail e k1. Sl) vie A U:0 N\ uto 1,0%io 919 City State Zip Fax Number: 4-25 Co1Z - ZC State State Fax Number: 4-26 - 0 2 - 2084- Zip Zip State Zip Day Telephone: 42S -174 352 o GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record Company Name: 2t6,2- 6-10 CX.YP I OC Mailing Address: 190 5G-T-4' I' b., klono W1A K O SZ City Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 2 Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System I !) Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION - 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name:_ Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ :± 100 0 Scope of Work (please provide detailed information): AOOt/..1 6 TyJC g.Lt TI iUS l5 CD1-4 JXrL-`(L Qcvuk LottO Mt. o tuJCA 1.1CTS. ic - r ?Wit-lc. 4 csO4 c'2ot_ Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... Fuel Type: Electric 2 Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Q:Upplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 Date Application Accepted: Ln I 01... Date Application Expires: I Staff Initials: I PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OR " H t,RIZED AGENT: Signature: ., Print Name: (] 4 2J5 Via' Iten } r Mailing Address: IcO t 5 36 l6..0c Li_SOt1t A Q :\Applications\Fonns-Applications On Lind3-2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: L1(n1r.1 City Date: l Z 7 L 4Z5- 174 -3P25 State Zip v Page 6 of 6 Payee: P S R ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 7340600480 Permit Number: M07 -192 Address: 12400 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 09/07/2007 Applicant: GROUP HEALTH Issue Date: Receipt No.: R07 -02159 Payment Amount: $804.40 Initials: LAW Payment Date: 10/02/2007 12:24 PM User ID: 1632 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 011437 804.40 Account Code Current Pmts 000/322.100 804.40 Total: $804.40 17529 10/02 F710 TOTAL ETpf doc: Receiot -06 Printed: 10 -02 -2007 Receipt No.: R07 -01922 Payee: RICE GROUP, INC. ACCOUNT ITEM LIST: Descript PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 7340600480 Permit Number: M07 -192 Address: 12400 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 09/07/2007 Applicant: GROUP HEALTH Issue Date: Initials: JEM Payment Date: 09/07/2007 04:34 PM User ID: 1165 Balance: $804.40 TRANSACTION LIST: Type Method Description Amount Payment Check 19723 193.60 Account Code Current Pmts 000/345.830 193.60 Total: $193.60 Payment Amount: $193.60 2598 09/10 9710 TOTAL 193.60 rinc: RAmintdlf Printar• 09-17 -2007 COMMENTS: t k. e._ S r` 4c.f eS A 1 1- tr LA-A_ 4;7 QPe.r\ Date Called:A. (t d J j h J N■ AJ/ -/ M.� (J4 1--,, e�UA4 's . 1(, pate Wanted: 2��(� 4-e p'1.r (4Ae-f\- J )'J , i d% e Requester: Phone No 206 Kr/66 P i re r ,�f 6 ^ Aft ra `� k �o 4 Project: Type of Inspection A ute Address: 1146 a r • tj.>t - J Date Called:A. (t d J j h J N■ AJ/ -/ Special Instructions: c frf t (y — (LA / N JJ pate Wanted: 2��(� p.m. Requester: Phone No 206 Kr/66 Mb INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. I Date:/2_ , 2Cr �V {, $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Inspect(r: 1 Receipt No.: 'Date: ��i 07 -15 -2008 CHRIS WRIGHT 19015 36 AV W, STE A LYNNWOOD WA 98036 City of Tukwila RE: Permit No. M07 -192 12400 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/27/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: fer Marshall • Technician Permit File No. M07 -192 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 02 -12 -2008 CHRIS WRIGHT 19015 36 AV W, STE A LYNNWOOD WA 98036 RE: Permit No. M07 -192 12400 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/05/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, Jennifi JMarshall Permit Technician xc: Permit File No. M07 -192 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 ACTIVITY NUMBER: M07 -192 DATE: 09 -07 -07 PROJECT NAME: GROUP HEALTH SITE ADDRESS: 12400 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: qv Bui ing DYirisf Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 .� PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Fire revention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Planning Division ❑ Permit Coordinator n DUE DATE: 09-11-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 10-09-07 Approved ❑ Approved with Conditions 1� Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: I License Information License PSR * ** *936JP Licensee Name P S R Licensee Type CONSTRUCTION CONTRACTOR U81 600122060 Verify Workers Comp Premium Status Ind. Ins. Account Id 34222200 Business Type CORPORATION Address 1 PO BOX 27073 LAKE CITY STATION Address 2 City SEATTLE County KING State WA Zip 981251473 Phone 2063672500 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/17/2007 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company PUGET SOUND REFRIGERATION INC Previous License PUGETSR169CB Next License Associated License Printer Friendly Version Look Up a Contractor, Electrician or Plumber Topic Index I Contact Info Search } r Safetyr Claims E Insurance Workplace Rights Trades & Licensing Find a Law or Rule Get a Form or Publication General /Specialty Contractor A business registered as a construction contractor with LFtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= PSR * ** *936JP 10/02/2007 RICE Group, Inc. Consulting Engineers 19015 36th Ave. W. Suite A Lynnwood, WA 98036 (425) 774 -3829 (425) 672 -2084 (FAX) RICE Group, Inc. September 28, 2007 City of Tukwila Department of community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 RE: Group Health AMB Chiller Replacement Permit #M07 -192 To Whom It May Concern, Please be advised that PSR will be the contractor for the above project. We have authorized them to pick up the permit for this project. T Ink you • L jc Chris Wrigh RICE Group, Inc. FAN SCHEDULE REVISIONS MFG' / MODEL NUMBER CFM E.S.P. INCHES W.G. FAN MOTOR NOISE DRIVE CONFIGURATION WEIGHT AREA SERVED REMARKS HP/ WATTS VOLTS Consulting Engineers -A) 19015 36th Ave. W. Suite A Lynnwood, Wa. 98036 (425) 774 -3829 FAX (425) 672 -2084 dBA F -1 GREENHECK BDF 180 -15 6000 0.5 3 208 3 70 BELT CENTRIF. CABINET 304 DATA ROOM i 1 F -2 r 6000 0.5 3 208 3 70 BELT CENTRIF. CABINET 304 DATE : 08/30/07 SCALE : AS SHOWN DRAWN: GLK CHECKED: C. WRIGHT 1,2 Ns . T . 1 :, 4 tot s i 5 1 0 0 fit •� /niJl1� � EXPIRES 7/12/08 1 I M 0 07.043 0 FAN SCHEDULE EQUIP. TAG MFG' / MODEL NUMBER CFM E.S.P. INCHES W.G. FAN MOTOR NOISE DRIVE CONFIGURATION WEIGHT AREA SERVED REMARKS HP/ WATTS VOLTS PH. dBA F -1 GREENHECK BDF 180 -15 6000 0.5 3 208 3 70 BELT CENTRIF. CABINET 304 DATA ROOM 1,2 F -2 GREENHECK BDF 180 -15 6000 0.5 3 208 3 70 BELT CENTRIF. CABINET 304 DATA ROOM 1,2 TEMP. FAN TO BE SINGLE PHASE MIN. 2000 CFM COORDINATE ELECTRICAL WITH ELECTRICIAN AND SITE AVALABLE POWER TYPICAL 2 LIGHTS TYP. II 18 "e TYP. 2 PROVIDE HIGH DENSITY FOAM BARRIER. WHERE PIPES, CONDUIT, CABLE OR CABLE TRAYS PENETRATE SEAL OPENINGS WITH DUCT TAPE ADJUST PLENUM TO FIT 24x48 CEILING PLENUM 12" HIGH SHEET METAL PLENUM SAME SIZE AS PANEL TYP. 2 0 • n A oa SCALE: NTS 4 0 0 TEMPORARY SHEET METAL BARRIER NOTES: 1) PROVIDE WITH 1" INSULATED CABINET 2) CONTROL FROM DDC SYSTEM. PROVIDE WITH CURRENT TRANSFORMER FOR PROOF OF OPE EQUIPMENT STAND MOVE & /OR RELOCATE HEADS. COORDINATE WITH FIRE MARCHALL. LIEBERT CRAC UNIT e 4 e SYMBOL LIST SYMBOL K5 N C6 ill V x 7C D CHS — CHR — LPS C RATION ABBV. PRV D CHS CHR LPS C DESCRIPTION BALL VALVE GATE VALVE CHECK VALVE GLOBE VALVE GAS COCK SOLENOID / MODULATING VALVE THREE -WAY VALVE RELIEF VALVE BALANCING VALVE FLOW CONTROL VALVE (SET FOR 1 GPM) AUTO -FLOW CONTROL VALVE PRESSURE REDUCING VALVE UNION THERMOMETER PRESSURE GAUGE VIBRATION ISOLATOR WATER HAMMER ARRESTOR STRAINER ANCHOR DRAIN CHILLED WATER SUPPLY CHILLED WATER RETURN LOW PRESSURE STEAM CONDENSATE SYMBOL I r e 10 CDL 300 CFM 3 (125) ABBV. T'STAT S COS AFF ARCH. CDS CDL CGS CGL COP DWG E, EXIST. ELECT. EC EER EFF FR GC HSPF HWR HWG I.E. IPLV LWR LWG MC MECH. OFCI POC TYP. U.O.N. DESCRIPTION THERMOSTAT SWITCH CARBON MONOXIDE SENSOR ABOVE FINISHED FLOOR ARCHITECT / ARCHITECTURAL CEILING DIFFUSER - SURFACE MOUNTED CEILING DIFFUSER -LAY IN CEILING GRILLE - SURFACE MOUNTED CEILING GRILLE -LAY IN COEFFICIENT OF PERFORMANCE DRAWING EXISTING ITEMS ELECTRICAL ELECTRICAL CONTRACTOR ENERGY EFFICIENCY RATING EFFICIENCY / EFFICIENT FLOOR REGISTER GENERAL CONTRACTOR HEATING SEASONAL PERFORMANCE FACTOR HIGH WALL REGISTER HIGH WALL GRILLE INVERT ELEVATION INTEGRATED PART LOAD VALUE LOW WALL REGISTER LOW WALL GRILLE MECHANICAL CONTRACTOR MECHANICAL OWNER FURNISHED, CONTRACTOR INSTALLED POINT OF CONNECTION TYPICAL UNLESS OTHERWISE NOTED PLUMBING FIXTURE TAG EQUIPMENT TAG CONNECTION (NECK) SIZE TYPE (CEILING DIFF. LAY -IN) FLOW RATE (CUBIC FEET PER MINUTE) FIXTURE UNITS or BTUH PIPE SIZE DETAIL NUMBER SHEET ON WHICH DETAIL IS DRAWN SECTION INDICATOR SHEET ON WHICH SECTION IS DRAWN REVISION TAG MOVE AS REQUIRED NEW RETURN AIR PLENUM p /— (SHEET METAL) PAINT TO MATCH CRAC UNIT 4 4 CEILING FLOORING SHEET METAL AIR SCOOP TEMPORARY BELOW - FLOOR- AIR - BARRIER AND FAN DETAIL CABLE TRAY 0 0 d PROVIDE HIGH DENSITY FOAM BARRIER. WHERE PIPES, CONDUIT, CABLE OR CABLE TRAYS PENETRATE SEAL OPENINGS WITH DUCT TAPE 4 0 e ADJUST PLENUM TO FIT 24x48 CEILING PLENUM PROVIDE HIGH DENSITY FOAM BARRIER. WHERE PIPES, CONDUIT, CABLE OR CABLE TRAYS PENETRATE SEAL OPENINGS WITH DUCT TAPE - SECTION SCALE: NTS PROVIDE AIR SCOOP (SHEET METAL) TO DIRECT FLOW TOWARDS COLD AISLE AS SHOWN ON FLOOR PLAN. CRAC'S 18, 21, 22, 23, 27 & 34. NOTES: 1) THIS PROJECT CONSISTS OF SERVICING, AND RELOCATING OF 20 COMPUTER ROOM AIR CONDITIONERS IN A MISSION CRITICAL COMPUTER ROOM. IN ADDITION, NEW PIPING WILL BE INSTALLED BELOW THE COMPUTER ROOM FLOOR TO PROVIDE THE COMPUTER ROOM MUST REMAIN OPERATIONAL 24 HOURS A DAY. EXTREME CARE MUST BE TAKEN TO MAINTAIN THE OPERATION OF THE COMPUTER ROOM. THIS INCLUDES: a. PROVIDING TEMPORARY COOLING TO MAINTAINING TEMPERATURE WITH IN THE SPACE b. PROVIDING ALL SERVICE OF EQUIPMENT OUTSIDE OF THE COMPUTER ROOM TO ELIMINATE POTENTIAL WATER LEAKS, AND DUST PRODUCING ACTIVITIES. c. PROVIDING ENCLOSURES AROUND THE WORK AREA TO ELIMINATE AIR FROM LEAKING OUT OF THE RAISED FLOOR. d. LIMITING THE LIFTING OF FLOOR TILES TO NO MORE THAN TWO FOR MORE THAN 5 MINUTES OUT SIDE OF WORK ENCLOSURE AREAS. EXCEEDING THIS WILL RAISE THE TEMPERATURE IN CRITICAL PARTS OF THE COMPUTER ROOM. 2) SERVICE ACCESS TO THE COMPUTER ROOM CAN BE PROVIDED FROM THE NORTH EXTERIOR DOOR. SEE PLANS 3) NOTE THAT THERE IS NO INTENT TO USE THE EXISTING HUMIDIFIERS IN THE COMPUTER ROOM AIR CONDITIONING UNITS. 4) PROVIDE A REPORT FOR EACH UNIT LISTING THE FINDINGS OF THE SERVICE REPORT. CLEARLY STATE ANY RECOMMENDATIONS FOR FURTHER REPAIR. 5) EXISTING CHILLED WATER LOOP CONTAINS ETHELYNE GLYCOL. DO NOT DUMP TO DRAIN. CHILLED WATER /GLYCOL MUST BE STORED & RE -USED. 6) TEMPORARY ELECTRICAL BY ELECTRICAL CONTRACTOR. PROVIDE PER UNIT COST FOR THE FOLLOWING a. REPLACEMENT OF COOLING COIL. b. REPLACEMENT OF MOTOR. c. REPLACEMENT OF ELECTRICAL CONTACTORS. d. REPLACEMENT OF FAN SHAFT. e. REPLACEMENT OF FAN BEARINGS. GENERAL NOTES ALL NEW CHILLED WATER PIPING SHALL BE BLACK WITH SCREWED FITTINGS STEEL WITH 1-1/2' FIBERGLASS INSULATION WITH A PVC JACKET. INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER I.B.C. REQUIREMENTS. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING OR ACCESSORY. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE AND ALL OTHER TRADES. THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, PIPES, UTILITIES AND BUILDING STRUCTURE. LOCATE ALL PLUMBING FIXTURES PER ARCHITECTURAL DRAWINGS. VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. RELOCATE EXISTING SPRINKLER HEADS & PROVIDE NEW HEADS AS REQUIRED TO MAINTAIN A COMPLETE AND OPERATIONAL AUTOMATIC FIRE SPRINLKER SYSTEM PER N.F.PA 13. PROVIDE ALL REQUIRED PIPING, HEADS AND ACCESSORIES. PROVIDE ALL REQUIRED CALCULATIONS. OBTAIN ANY REQUIRED PERMITS, AND PAY ALL REQUIRED FEES IN ORDER TO INSTALL A COMPLETE AND OPERATIONAL SYSTEM. ALL MECHANICAL EQUIPMENT LOCATED IN CEILING CAVITIES THAT REQUIRE ELECTRICAL CONNECTION SHALL HAVE AN 8 -1/2 "x11" LAMINATED SIGN PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 460V) AND 42" (460V AND ABOVE) ". NO TRADE SHALL BLOCK THIS SPACE EVEN IF SHOWN ON THE DRAWINGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. ENERGY CODE NOTES EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5 F. WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM. SEE SPECIFICATIONS. EACH HVAC SYSTEM SHALL HAVE AUTOMATIC CONTROLS WITH A MINIMUM SEVEN DAY CLOCK CAPABLE OF BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK. SEE SPECIFICATIONS. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH OWNER. AS -BUILT DRAWINGS SHALL BE PROVIDED TO BUILDING OWNER ACCORDING TO THE WSEC SECTION 1416.1. AN OPERATING AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE WSEC SECTION 1416.2. ALL SYSTEM SHALL BE BALANCED ACCORDING TO THE WSEC SECTION 1416.3. THE MECHANICAL SYSTEMS SHALL FOLLOW A SYSTEM COMMISSIONING PROCEDURE INCLUDING, BUT NOT LIMITED TO, PRELIMINARY REPORTS, TESTS, FINAL COMMISSIONING REPORTS AND ACCEPTANCE IN ACCORDANCE WITH THE WSEC 1416.4. SITE PLAN SCALE: 1 "= 100' -0" PLAN NORTH LOCATION City of Tukwila BUILDING DIVISION an review 4,.prova1 Is subject to ewers and omIssionE Approvd of c::-1:InIction documents does not author the vic, :atIon c; 4 "I c p':°d code or ordinary -. Rceeip of appro r- ' _ % 4^ - nd.tior ° L3 c vIedg REVISIONS No changes shall be made to the scope of work without prior approval of • Tukwila Building Division. • NOTE: Revisions will require a new plan submlttpl and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electr ical 0A,Plurnoing I Gas Piping City of Tukwila BUIL P!NC DIVISION RECEIVED CITY OF TUKWILA SEP 0 7 2007 vic.nivii l td1:.1lI I tbR IVM-M DRAWING INDEX SHEET NAME DESCRIPTION M1.0 COVER SHEET M2.0 HVAC PLAN - PHASE I - DUCTWORK M2.0A HVAC PLAN - PHASE I - CRACS M2.1 I HVAC PLAN -- PHASE II M2.2 , HVAC PLAN - PHASE III M2.3 HVAC PLAN - PHASE IV TEMP. FAN TO BE SINGLE PHASE MIN. 2000 CFM COORDINATE ELECTRICAL WITH ELECTRICIAN AND SITE AVALABLE POWER TYPICAL 2 LIGHTS TYP. II 18 "e TYP. 2 PROVIDE HIGH DENSITY FOAM BARRIER. WHERE PIPES, CONDUIT, CABLE OR CABLE TRAYS PENETRATE SEAL OPENINGS WITH DUCT TAPE ADJUST PLENUM TO FIT 24x48 CEILING PLENUM 12" HIGH SHEET METAL PLENUM SAME SIZE AS PANEL TYP. 2 0 • n A oa SCALE: NTS 4 0 0 TEMPORARY SHEET METAL BARRIER NOTES: 1) PROVIDE WITH 1" INSULATED CABINET 2) CONTROL FROM DDC SYSTEM. PROVIDE WITH CURRENT TRANSFORMER FOR PROOF OF OPE EQUIPMENT STAND MOVE & /OR RELOCATE HEADS. COORDINATE WITH FIRE MARCHALL. LIEBERT CRAC UNIT e 4 e SYMBOL LIST SYMBOL K5 N C6 ill V x 7C D CHS — CHR — LPS C RATION ABBV. PRV D CHS CHR LPS C DESCRIPTION BALL VALVE GATE VALVE CHECK VALVE GLOBE VALVE GAS COCK SOLENOID / MODULATING VALVE THREE -WAY VALVE RELIEF VALVE BALANCING VALVE FLOW CONTROL VALVE (SET FOR 1 GPM) AUTO -FLOW CONTROL VALVE PRESSURE REDUCING VALVE UNION THERMOMETER PRESSURE GAUGE VIBRATION ISOLATOR WATER HAMMER ARRESTOR STRAINER ANCHOR DRAIN CHILLED WATER SUPPLY CHILLED WATER RETURN LOW PRESSURE STEAM CONDENSATE SYMBOL I r e 10 CDL 300 CFM 3 (125) ABBV. T'STAT S COS AFF ARCH. CDS CDL CGS CGL COP DWG E, EXIST. ELECT. EC EER EFF FR GC HSPF HWR HWG I.E. IPLV LWR LWG MC MECH. OFCI POC TYP. U.O.N. DESCRIPTION THERMOSTAT SWITCH CARBON MONOXIDE SENSOR ABOVE FINISHED FLOOR ARCHITECT / ARCHITECTURAL CEILING DIFFUSER - SURFACE MOUNTED CEILING DIFFUSER -LAY IN CEILING GRILLE - SURFACE MOUNTED CEILING GRILLE -LAY IN COEFFICIENT OF PERFORMANCE DRAWING EXISTING ITEMS ELECTRICAL ELECTRICAL CONTRACTOR ENERGY EFFICIENCY RATING EFFICIENCY / EFFICIENT FLOOR REGISTER GENERAL CONTRACTOR HEATING SEASONAL PERFORMANCE FACTOR HIGH WALL REGISTER HIGH WALL GRILLE INVERT ELEVATION INTEGRATED PART LOAD VALUE LOW WALL REGISTER LOW WALL GRILLE MECHANICAL CONTRACTOR MECHANICAL OWNER FURNISHED, CONTRACTOR INSTALLED POINT OF CONNECTION TYPICAL UNLESS OTHERWISE NOTED PLUMBING FIXTURE TAG EQUIPMENT TAG CONNECTION (NECK) SIZE TYPE (CEILING DIFF. LAY -IN) FLOW RATE (CUBIC FEET PER MINUTE) FIXTURE UNITS or BTUH PIPE SIZE DETAIL NUMBER SHEET ON WHICH DETAIL IS DRAWN SECTION INDICATOR SHEET ON WHICH SECTION IS DRAWN REVISION TAG MOVE AS REQUIRED NEW RETURN AIR PLENUM p /— (SHEET METAL) PAINT TO MATCH CRAC UNIT 4 4 CEILING FLOORING SHEET METAL AIR SCOOP TEMPORARY BELOW - FLOOR- AIR - BARRIER AND FAN DETAIL CABLE TRAY 0 0 d PROVIDE HIGH DENSITY FOAM BARRIER. WHERE PIPES, CONDUIT, CABLE OR CABLE TRAYS PENETRATE SEAL OPENINGS WITH DUCT TAPE 4 0 e ADJUST PLENUM TO FIT 24x48 CEILING PLENUM PROVIDE HIGH DENSITY FOAM BARRIER. WHERE PIPES, CONDUIT, CABLE OR CABLE TRAYS PENETRATE SEAL OPENINGS WITH DUCT TAPE - SECTION SCALE: NTS PROVIDE AIR SCOOP (SHEET METAL) TO DIRECT FLOW TOWARDS COLD AISLE AS SHOWN ON FLOOR PLAN. CRAC'S 18, 21, 22, 23, 27 & 34. NOTES: 1) THIS PROJECT CONSISTS OF SERVICING, AND RELOCATING OF 20 COMPUTER ROOM AIR CONDITIONERS IN A MISSION CRITICAL COMPUTER ROOM. IN ADDITION, NEW PIPING WILL BE INSTALLED BELOW THE COMPUTER ROOM FLOOR TO PROVIDE THE COMPUTER ROOM MUST REMAIN OPERATIONAL 24 HOURS A DAY. EXTREME CARE MUST BE TAKEN TO MAINTAIN THE OPERATION OF THE COMPUTER ROOM. THIS INCLUDES: a. PROVIDING TEMPORARY COOLING TO MAINTAINING TEMPERATURE WITH IN THE SPACE b. PROVIDING ALL SERVICE OF EQUIPMENT OUTSIDE OF THE COMPUTER ROOM TO ELIMINATE POTENTIAL WATER LEAKS, AND DUST PRODUCING ACTIVITIES. c. PROVIDING ENCLOSURES AROUND THE WORK AREA TO ELIMINATE AIR FROM LEAKING OUT OF THE RAISED FLOOR. d. LIMITING THE LIFTING OF FLOOR TILES TO NO MORE THAN TWO FOR MORE THAN 5 MINUTES OUT SIDE OF WORK ENCLOSURE AREAS. EXCEEDING THIS WILL RAISE THE TEMPERATURE IN CRITICAL PARTS OF THE COMPUTER ROOM. 2) SERVICE ACCESS TO THE COMPUTER ROOM CAN BE PROVIDED FROM THE NORTH EXTERIOR DOOR. SEE PLANS 3) NOTE THAT THERE IS NO INTENT TO USE THE EXISTING HUMIDIFIERS IN THE COMPUTER ROOM AIR CONDITIONING UNITS. 4) PROVIDE A REPORT FOR EACH UNIT LISTING THE FINDINGS OF THE SERVICE REPORT. CLEARLY STATE ANY RECOMMENDATIONS FOR FURTHER REPAIR. 5) EXISTING CHILLED WATER LOOP CONTAINS ETHELYNE GLYCOL. DO NOT DUMP TO DRAIN. CHILLED WATER /GLYCOL MUST BE STORED & RE -USED. 6) TEMPORARY ELECTRICAL BY ELECTRICAL CONTRACTOR. PROVIDE PER UNIT COST FOR THE FOLLOWING a. REPLACEMENT OF COOLING COIL. b. REPLACEMENT OF MOTOR. c. REPLACEMENT OF ELECTRICAL CONTACTORS. d. REPLACEMENT OF FAN SHAFT. e. REPLACEMENT OF FAN BEARINGS. GENERAL NOTES ALL NEW CHILLED WATER PIPING SHALL BE BLACK WITH SCREWED FITTINGS STEEL WITH 1-1/2' FIBERGLASS INSULATION WITH A PVC JACKET. INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER I.B.C. REQUIREMENTS. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING OR ACCESSORY. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE AND ALL OTHER TRADES. THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, PIPES, UTILITIES AND BUILDING STRUCTURE. LOCATE ALL PLUMBING FIXTURES PER ARCHITECTURAL DRAWINGS. VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. RELOCATE EXISTING SPRINKLER HEADS & PROVIDE NEW HEADS AS REQUIRED TO MAINTAIN A COMPLETE AND OPERATIONAL AUTOMATIC FIRE SPRINLKER SYSTEM PER N.F.PA 13. PROVIDE ALL REQUIRED PIPING, HEADS AND ACCESSORIES. PROVIDE ALL REQUIRED CALCULATIONS. OBTAIN ANY REQUIRED PERMITS, AND PAY ALL REQUIRED FEES IN ORDER TO INSTALL A COMPLETE AND OPERATIONAL SYSTEM. ALL MECHANICAL EQUIPMENT LOCATED IN CEILING CAVITIES THAT REQUIRE ELECTRICAL CONNECTION SHALL HAVE AN 8 -1/2 "x11" LAMINATED SIGN PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 460V) AND 42" (460V AND ABOVE) ". NO TRADE SHALL BLOCK THIS SPACE EVEN IF SHOWN ON THE DRAWINGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. ENERGY CODE NOTES EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5 F. WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM. SEE SPECIFICATIONS. EACH HVAC SYSTEM SHALL HAVE AUTOMATIC CONTROLS WITH A MINIMUM SEVEN DAY CLOCK CAPABLE OF BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK. SEE SPECIFICATIONS. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH OWNER. AS -BUILT DRAWINGS SHALL BE PROVIDED TO BUILDING OWNER ACCORDING TO THE WSEC SECTION 1416.1. AN OPERATING AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE WSEC SECTION 1416.2. ALL SYSTEM SHALL BE BALANCED ACCORDING TO THE WSEC SECTION 1416.3. THE MECHANICAL SYSTEMS SHALL FOLLOW A SYSTEM COMMISSIONING PROCEDURE INCLUDING, BUT NOT LIMITED TO, PRELIMINARY REPORTS, TESTS, FINAL COMMISSIONING REPORTS AND ACCEPTANCE IN ACCORDANCE WITH THE WSEC 1416.4. SITE PLAN SCALE: 1 "= 100' -0" PLAN NORTH LOCATION City of Tukwila BUILDING DIVISION an review 4,.prova1 Is subject to ewers and omIssionE Approvd of c::-1:InIction documents does not author the vic, :atIon c; 4 "I c p':°d code or ordinary -. Rceeip of appro r- ' _ % 4^ - nd.tior ° L3 c vIedg REVISIONS No changes shall be made to the scope of work without prior approval of • Tukwila Building Division. • NOTE: Revisions will require a new plan submlttpl and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electr ical 0A,Plurnoing I Gas Piping City of Tukwila BUIL P!NC DIVISION RECEIVED CITY OF TUKWILA SEP 0 7 2007 vic.nivii l td1:.1lI I tbR IVM-M I' 177-'7-7 i I� I , II L.- II i -- •• _.; ��4.I.._I ; _ I i __..... �......_. 1 \> '!i I _ _....__ i _ __ - ' • - I - r .- _.._......_ J1 _ �1 \ i . �L.� I I III \\ II I - I r 1- I i I I j I I11 f ` r 4 I i • ---- - -- _. 1 -r - • - r I I l U P 7 I yl tt 11 i 1 f I.' 1 SEALER \ i • - _ r_ rt_ -.` — . ._. t.- � r .., , / / /1 II II rDECOL A;OR 1 , I Ij SHRINK'WRAP FOLDER/STIFFER i DTI 1- 1 _._ rt.... ®� ; 1 CAKE RACK CAKE RACK CAKE RACK I CAKE RACK 11 ,1 • C-, TAPE 30 "x36" OVER GRILLES L - -J CARTS 1- L_Ji DATAJASE 36x36 DESK RELOCATE JGHTS AS REQUIRED 2 4x24 CGL 2500 CFM ;TYP 4) 36x36 D =SK Ir it \ \ +I Il ALL WORK THIS SHEET IN CEIUNG CAVITY 36x36 SOUNDLINED 7 24x24 CG 2500 CF'M (TYP 4) O C-) 30 "x36" OVER GRILLES T /1 . / i - Jam I J - _ .._...__, PLAN NORTH EF II �1 EMOVE CEILING TILE & GRID TO INSTALL FANS & DUCTWORK. RE-INSTALL WHEN COMPLETE COUNTER 36x36 SOUNDUNED SCALE: 1/8” = 1' -O" CONSOLES (3) I. FLOOR PLAN - HVAC EZZ ZZ IZZ M' i II TEMPORARILY REMOVE (8) CEILING TILES, STORE & REPLACE AFTER WORK IS COMPLETED II L (J Q N EW SIEMENS CONTROL PANEL (BY GROUP HEALTH & SIEMENS) CONTACT GRNG ROLPH GROUP HEALTH Q IX J_ ADD ±70 24x24 CGL'S EVENLY DISTRIBUTED IN CEILING MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION r \\ ,,; 1 t 5 \ , \\ f \ ' y • 1 I' r' }� \ 'y 1 , , 1 \ \ \ \ \1 + . 1__ 1 1 , � 1 I l\ \ 1 1 ' \ \\ 1\ --- \_A t, 1 '. \ \ ( i \ \ \t \\ \\, .1 i \ \ \ :, 1 t \ I 1, l � --, 1 \ \..- 5 -.,, \\,\ 1 1 1 1 , i \ , , , 11 1 1, \\ 1, 4 I \ tl ' �- _ ; \ 1 1 1 1. i t 1 \\ ,1 \ \ ,\ 1,, \ \_ ,...\ I __ \ __' e - � , I VV PHASE I CITY OF RECEIVED SEP 0 7 200 E'truvla I U I R REVISIONS C) C 0 L� w <lc P 2 V Q ce 1:13 CD a DATE: SCALE: DRAWN: CHECKED: 08130107 AS SHOWN GLK C. WRIGHT EXPIRES 7/12/08 Lla CD re CO y T < o CV I M2,0 07-043 Q co 7 = < 0 '33 N J J �w 0) (.0 N rO ¢ O O N �r•� i =per N V U1 J' E IL .1J 1 _ ..I r- �_....___�— _.—_J_ 1 N 7 - F / „/„/ / / / f % " 4- 1 i H I , 1 . ' 1 1 .- _� I f x \\ \ \k\ / /A2.1 11 k 40.14.0 NEW NEW LOCATION!- OF CRAC -21 TTTTTTTTT «t «ttttt fff4 ♦ «ft «♦ 1 t 1 t 4t « NWintootov r SOLES 7.7711R t • i i • i 4, •_tom *«_i ����• 1r.,5EAlR� 109303F 1 i I I I �: L ` 'i I 16: - 16 1— ' — \\t CRAC (E) 1986 FH200C —A00 109303E1- -- SHRINKWRAP - 1 • J -- � ;CECCLLATCR \ T \ / • 1 ' < L FOLDER/STUFFER R I5, H L T L NEW LOCATION OF CRAC -27. EXTEND PIPING AS REQUIRED 1986 FH200C —A00 (E) 1093030 U, a U !. II I __Li DATA TAPE CARTS I 161 (E) I 1990 FH302C —A00 157100 -002 i ' ' 1990 FH302C —A00 157100 -003 CAKE RACK i CAKE RACK 1 CAKE RAC'( T CAKE RACK I (E) (E) 1 09303H 1990 FH302C —A00 (E) 157100 -002 109303M (E) (E) 1986 FH200C —A00 109303A c-> c. — : - • r� A PLAN NORTH I& — (E T 1990 FH302C —A00 157100 -001 1 L I ( I 109303J FH302C —A00 I (3) • L U, LJ (E) ) 1986 1093031 FLOOR PLAN - HVAC SCALE: 1/8" = 1' -0" 1 1 L i L \\ 1991 s C FH302C -A00 170120 -o61 TABLE 1 -- L__ (BY GROUP HEALTH & SIEMENS) L CONTACT CRAIG ROLPH 0 GROUP HEALTH K CF : (E) FH302C --A00 (E) FH302C —A00 109303K MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION (E) 1991 FH302 —A00 166662 -003 (E) 1991 FH302—A00 166662 -002 (E) 1666602 -001 (E) (E) 1666602-004 \ \ SIDE PANEL MISSING \ \ SITTING ON A PALLET ,. ', FHC 302 A008 I `t `l 1 PROVIDE NEW DISCONNECT KNOB LEGEND PERMANENT 1991 TEMPORARY CRAC UNITS (E) 166662 -008 FHC 302 A00 �tft ♦tt «f « •••••■•••• .. «ttttt.t, t t •t « + « + « + «t f f f +, CRAC UNITS 1991 166662-005 DISCONNECT \ KNOB \ \ MISSING 1'. {4 ` '1 t\ \\ 1. ,1 1991 _ -� 166662 -0 FH302 A00 08 (E) PHASE II FLAG NOTES PROVIDE SERVICE ON CRAC UNITS 18, 19, 1, 21, 22, 23, 34, 25, 27. CONTRACTOR TO PROVIDE SERVICE ON EACH UNIT PRIOR TO RELOCATING. SERVICE SHALL INCLUDE THE FOLLOWING: A. FLUSH COOLING COIL WITH DE— SCALER. B. PRESSURE TEST COOLING COIL AT 100 PSI FOR 24 HOURS. C. REPLACE SHEAVES, TEST MOTOR. D. REPLACE FAN BELTS. E. REPLACE FAN BEARINGS. F. REPLACE CONTROL VALVE. G. TEST ELECTRICAL CONTRACTORS. H. RUN FAN AND CHECK BEARINGS. I. VISUALLY INSPECT CONTACTORS. J. CHECK CONTROLS. MOVE CRAC -18 TO NEW LOCATION. PROVIDE NEW TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATION ONLY AFTER CRAC -18 IS UP AND OPERATING, SWITCH LOCATIONS OF CRAG -5 WITH CRAC -19. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -19. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -19 TO DDC CONTROL SYSTEM. RE —USE EXISTING WIRING. ONLY AFTER CRAC -19 IS UP AND OPERATING, MOVE CRAC -18 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATON. SWITCH LOCATIONS OF CRAC -14 WITH CRAC -1(FHC 302 A008). CONNECT ELECTRICAL AND CHILLED WATER TO CRAC-1(FHC 302 A008). MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -1 TO DDC SYSTEM. RE —USE EXISTING WIRING. ONLY AFTER CRAC -1 IS UP AND IN OPERATION, RELOCATE CRAC -15 TO WHERE WITH CRAC -21 IS LOCATED, CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -21. INSTALL NEW 1-1/2" CHILLED WATER PIPE TO LOCATION OF CRAC-21. CONNECT ELECTRICAL & CHILLED WATER TO CRAC -21. PROVIDE NEW LEAK DETECTION SYTSTEM & CONNECT TROUBLE ALARM TO DDC. COORDINATE EXACT LOCATION OF DDC INTERFACE WITH OWNER (CRAIG ROLF). NEW LEAK DETECTION SYSTEM SHALL BE VERIS MP SERIES WITH 30' OF CABLE. INTER — CONNECT THE DDC SYSTEM. RELOCATE CRAC -21 TO NEW LOCATION AFTER CRAC -21 IS UP AND OPERATING, MOVE CRAC -18 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATON. ONLY AFTER CRAC-18 IS UP AND OPERATING SWITCH LOCATIONS OF CRAC -16 WITH CRAG -22. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -22. MAINTAIN LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -22 TO DDC SYSTEM, RE—USE EXISTING WIRING. ONLY AFTER CRAG --22 IS UP AND OPERATIING, SWITCH LOCATIONS OF CRAC -10 WITH CRAC -23. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -23. MAINTAIN LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -23 TO DDC SYSTEM. RE —USE EXISTING WIRING. ONLY AFTER CRAC -23 IS UP AND OPERATING, MOVE CRAC -18 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATON. ONLY AFTER CRAC -18 IS UP AND OPERATING, SWITCH LOCATIONS OF CRAG -11 WITH CRAC -25. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -25. MAINTAIN LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -25 TO DDC SYSTEM. RE —USE EXISTING WIRING. ONLY AFTER CRAC -25 IS UP AND OPERATING, SWITCH LOCATIONS OF CRAC -17 WITH CRAC -27. RELOCATE CRAC -27 TO LOCATION INDICATED ON PLANS. RELOCATE EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAG -27 TO DDC SYSTEM. EXTEND EXISTING WIRING. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -27. * ADD TEMPORARY HOSE EITHER UNDER FLOOR THROUGH MAIN AISLE OR OVER CEILING THROUGH MAIN AISLE. RECEIVED CITY OF TUKWILA SEP 0 7 2007 'Fcnival ! U =IV I t{� COMPUTER RACK REVISIONS 1) Consulting Engineers 19015 36th Ave. W. „1 .0 ) Suite A Lynnwood, Wa. 98036 (425) 774-3829 FAX (425) 672-2084 1 AN I DATE : 08/30/07 SCALE : AS SHOWN DRAWN: GLK CHECKED : C. WRIGHT , a te , ( I. r r>� . 41JAL ti EXPIRES 7/12/08 M2 07-043 J .1J 1 _ ..I r- �_....___�— _.—_J_ 1 N 7 - F / „/„/ / / / f % " 4- 1 i H I , 1 . ' 1 1 .- _� I f x \\ \ \k\ / /A2.1 11 k 40.14.0 NEW NEW LOCATION!- OF CRAC -21 TTTTTTTTT «t «ttttt fff4 ♦ «ft «♦ 1 t 1 t 4t « NWintootov r SOLES 7.7711R t • i i • i 4, •_tom *«_i ����• 1r.,5EAlR� 109303F 1 i I I I �: L ` 'i I 16: - 16 1— ' — \\t CRAC (E) 1986 FH200C —A00 109303E1- -- SHRINKWRAP - 1 • J -- � ;CECCLLATCR \ T \ / • 1 ' < L FOLDER/STUFFER R I5, H L T L NEW LOCATION OF CRAC -27. EXTEND PIPING AS REQUIRED 1986 FH200C —A00 (E) 1093030 U, a U !. II I __Li DATA TAPE CARTS I 161 (E) I 1990 FH302C —A00 157100 -002 i ' ' 1990 FH302C —A00 157100 -003 CAKE RACK i CAKE RACK 1 CAKE RAC'( T CAKE RACK I (E) (E) 1 09303H 1990 FH302C —A00 (E) 157100 -002 109303M (E) (E) 1986 FH200C —A00 109303A c-> c. — : - • r� A PLAN NORTH I& — (E T 1990 FH302C —A00 157100 -001 1 L I ( I 109303J FH302C —A00 I (3) • L U, LJ (E) ) 1986 1093031 FLOOR PLAN - HVAC SCALE: 1/8" = 1' -0" 1 1 L i L \\ 1991 s C FH302C -A00 170120 -o61 TABLE 1 -- L__ (BY GROUP HEALTH & SIEMENS) L CONTACT CRAIG ROLPH 0 GROUP HEALTH K CF : (E) FH302C --A00 (E) FH302C —A00 109303K MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION (E) 1991 FH302 —A00 166662 -003 (E) 1991 FH302—A00 166662 -002 (E) 1666602 -001 (E) (E) 1666602-004 \ \ SIDE PANEL MISSING \ \ SITTING ON A PALLET ,. ', FHC 302 A008 I `t `l 1 PROVIDE NEW DISCONNECT KNOB LEGEND PERMANENT 1991 TEMPORARY CRAC UNITS (E) 166662 -008 FHC 302 A00 �tft ♦tt «f « •••••■•••• .. «ttttt.t, t t •t « + « + « + «t f f f +, CRAC UNITS 1991 166662-005 DISCONNECT \ KNOB \ \ MISSING 1'. {4 ` '1 t\ \\ 1. ,1 1991 _ -� 166662 -0 FH302 A00 08 (E) PHASE II FLAG NOTES PROVIDE SERVICE ON CRAC UNITS 18, 19, 1, 21, 22, 23, 34, 25, 27. CONTRACTOR TO PROVIDE SERVICE ON EACH UNIT PRIOR TO RELOCATING. SERVICE SHALL INCLUDE THE FOLLOWING: A. FLUSH COOLING COIL WITH DE— SCALER. B. PRESSURE TEST COOLING COIL AT 100 PSI FOR 24 HOURS. C. REPLACE SHEAVES, TEST MOTOR. D. REPLACE FAN BELTS. E. REPLACE FAN BEARINGS. F. REPLACE CONTROL VALVE. G. TEST ELECTRICAL CONTRACTORS. H. RUN FAN AND CHECK BEARINGS. I. VISUALLY INSPECT CONTACTORS. J. CHECK CONTROLS. MOVE CRAC -18 TO NEW LOCATION. PROVIDE NEW TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATION ONLY AFTER CRAC -18 IS UP AND OPERATING, SWITCH LOCATIONS OF CRAG -5 WITH CRAC -19. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -19. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -19 TO DDC CONTROL SYSTEM. RE —USE EXISTING WIRING. ONLY AFTER CRAC -19 IS UP AND OPERATING, MOVE CRAC -18 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATON. SWITCH LOCATIONS OF CRAC -14 WITH CRAC -1(FHC 302 A008). CONNECT ELECTRICAL AND CHILLED WATER TO CRAC-1(FHC 302 A008). MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -1 TO DDC SYSTEM. RE —USE EXISTING WIRING. ONLY AFTER CRAC -1 IS UP AND IN OPERATION, RELOCATE CRAC -15 TO WHERE WITH CRAC -21 IS LOCATED, CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -21. INSTALL NEW 1-1/2" CHILLED WATER PIPE TO LOCATION OF CRAC-21. CONNECT ELECTRICAL & CHILLED WATER TO CRAC -21. PROVIDE NEW LEAK DETECTION SYTSTEM & CONNECT TROUBLE ALARM TO DDC. COORDINATE EXACT LOCATION OF DDC INTERFACE WITH OWNER (CRAIG ROLF). NEW LEAK DETECTION SYSTEM SHALL BE VERIS MP SERIES WITH 30' OF CABLE. INTER — CONNECT THE DDC SYSTEM. RELOCATE CRAC -21 TO NEW LOCATION AFTER CRAC -21 IS UP AND OPERATING, MOVE CRAC -18 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATON. ONLY AFTER CRAC-18 IS UP AND OPERATING SWITCH LOCATIONS OF CRAC -16 WITH CRAG -22. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -22. MAINTAIN LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -22 TO DDC SYSTEM, RE—USE EXISTING WIRING. ONLY AFTER CRAG --22 IS UP AND OPERATIING, SWITCH LOCATIONS OF CRAC -10 WITH CRAC -23. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -23. MAINTAIN LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -23 TO DDC SYSTEM. RE —USE EXISTING WIRING. ONLY AFTER CRAC -23 IS UP AND OPERATING, MOVE CRAC -18 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATON. ONLY AFTER CRAC -18 IS UP AND OPERATING, SWITCH LOCATIONS OF CRAG -11 WITH CRAC -25. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -25. MAINTAIN LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -25 TO DDC SYSTEM. RE —USE EXISTING WIRING. ONLY AFTER CRAC -25 IS UP AND OPERATING, SWITCH LOCATIONS OF CRAC -17 WITH CRAC -27. RELOCATE CRAC -27 TO LOCATION INDICATED ON PLANS. RELOCATE EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAG -27 TO DDC SYSTEM. EXTEND EXISTING WIRING. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -27. * ADD TEMPORARY HOSE EITHER UNDER FLOOR THROUGH MAIN AISLE OR OVER CEILING THROUGH MAIN AISLE. RECEIVED CITY OF TUKWILA SEP 0 7 2007 'Fcnival ! U =IV I t{� COMPUTER RACK i � i — ▪ ,/— 171 I 1. II Ij �. . iii! \' (I( 1 ,Ill ;�•-1 / / �I /1/ / / Ii 11 N !N I II L T Fi �. , • I -- -I---1 - / -. _.. LSEAIEP' \\ —11 \\\ 111 1 U Fl II i i "! ! \ 1991 FH302 -A00 165.6.62 - Qn 7 --r / I PROVIDE NEW I SIDE PANEL � COUNTER 1666602 -004 SIDE PANEL MISSING SITTING ON A PALLET FHC 302 A008 CCPI501_ES (3) 1093031 - 1(77_ { ; ? i I CAKE RACK I CAKE RACK I CAKE RACK CAKE RACK /CRAG (E) 1986 FH200C -A00 1093030 -• -- IDEC0I LATOR I r I... SNRi!('+4� (E) 1991 FH302 -A00 166662 -003 (E) I EOLDER/5TUFEER _ = � 7 I L L 1 -_- _. I Ii E 1 - li ,r j 1 1 I T1 LT-1 N X 7 .,....,,.— L I j 4,,,. . I— ' L "T (E) ( 1991 FH302C -A00 170120 -001 166662 -008 Fl-IC 302 A00 1986 FH200C -A00 (E) 109303C I - - - - - I L.. TAPE CARTS I CRAC re w LJ_. EOATA 3.8SE -2ART • (E) 1991 FH302 -A00 166662 -008 I j (E) PROVIDE NEW DISCONNECT KNOB 109303M (E) (E) 1986 F1-1200C -A00 109303A (E) 1991 166662 -005 PLAN NORTH I L L SCALE: 1 /8" = 1. -0" 1666602 -001 (E) \ L \ NEW SIEMENS CONTROL PANEL (BY GROUP HEALTH & SIEMENS) CONTACT GRAIG ROLPH ® GROUP HEALTH FLOOR PLAN LA v o \ I LI - - ■ CC TABLE \ J 1990 F1-1302C -ADO 157100 -003 f N I 109303) (E) F1-1302C -A00 FH302C -A00 109303K MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION (E) 109303F / A (E) 109303H (E) � 109303) FH302C --A00 (E) 1989 FH302C -A00 149492A (E) \ / 1990 FH302C- ADO 157100 -002 1990 FH3O2C -A00 157100-001 CRAC (E) 15 ) 1990 FH302C -A00 (E) 157100 --002 CRAC UNITS LEGEND PERMANENT 1991 TEMPORARY 4,••••••••■4 •••••••••• CRAC UNITS MOVE CRAC -18 TO NEW LOCATION. MOVE CRAC-17 TO NEW LOCATION. PHASE III FLAG NOTES * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE ELECTRICAL, START UNIT AND PLACE IN OPERATION. SWITCH LOCATIONS OF CRAC -34 WITH CRAC -12. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC-34. MIANTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC-34 TO DDC SYSTEM. RE -USE EXISTING WIRING. PROVIDE SERVICE ON CRAG UNITS 5, 14, 16, 10, 11, 17, 12. CONTRACTOR TO PROVIDE SERVICE ON EACH UNIT PRIOR TO RELOCATING. SERVICE SHALL INCLUDE THE FOLLOWING: A. FLUSH COOLING COIL WITH DE- SCALER. B. PRESSURE TEST COOLING COIL AT 100 PSI FOR 24 HOURS. C. REPLACE SHEAVES & TEST MOTOR. D. REPLACE FAN BELTS. E. REPLACE FAN BEARINGS. F. REPLACE CONTROL VALVE. G. TEST ELECTRICAL CONTRACTORS. H. RUN FAN AND CHECK BEARINGS. I. VISUALLY INSPECT CONTACTORS. J. CHECK CONTROLS. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -17. PROVIDE ELECTRICAL, START UNIT AND PLACE IN OPERATION, SWITCH LOCATIONS OF CRAC -9 WITH CRAC -11. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -9. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -11 TO DDC SYSTEM. RE -USE EXISTING WIRING. ONLY AFTER CRAC -9 IS UP AND IN OPERATION, SWITCH LOCATIONS OF CRAC -8 WITH CRAC -10. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -10. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -10 TO DDC SYSTEM. RE -USE EXISTING WIRING. ONLY AFTER CRAC-10 IS UP AND IN OPERATING, MOVE CRAC-17 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC-17. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATON. ONLY AFTER CRAC-17 IS UP AND IN OPERATION, SWITCH LOCATIONS OF CRAC-7 WITH CRAC -16. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC-16. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALMM FROM CRAC-16 TO DDC SYSTEM. RE-USE EXISTING WIRING. ONLY AFTER CRAC-16 IS UP AND IN OPERATION, SWITCH LOCATIONS OF CRAC-6 WIThl CRAC-12. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC-34. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC-12 TO DDC SYSTEM. RE-USE EXISTING * ADD TEMPORARY HOSE EITHER UNDER FLOOR THROUGH MAIN AISLE OR OVER CEILING THROUGH MAIN AISLE. RECEIVED CITY OF TUKWILA COMPUTER RACK REVISIONS Consulting Engineers ''....V) 19015 36th Ave. W. Suite A Lynnwood, Wa. 98036 (425) 774 -3829 FAX (425) 672 -2084 H 1 I DATE : 08130/07 SCALE : AS SHOWN DRAWN: GLK CHECKED: C. WRIGHT \S I`lli'j 1 3* " t„ . � \ ) I\JI , 1. EXPIRES 7/1 2/08 I 2.1 07043 4 i � i — ▪ ,/— 171 I 1. II Ij �. . iii! \' (I( 1 ,Ill ;�•-1 / / �I /1/ / / Ii 11 N !N I II L T Fi �. , • I -- -I---1 - / -. _.. LSEAIEP' \\ —11 \\\ 111 1 U Fl II i i "! ! \ 1991 FH302 -A00 165.6.62 - Qn 7 --r / I PROVIDE NEW I SIDE PANEL � COUNTER 1666602 -004 SIDE PANEL MISSING SITTING ON A PALLET FHC 302 A008 CCPI501_ES (3) 1093031 - 1(77_ { ; ? i I CAKE RACK I CAKE RACK I CAKE RACK CAKE RACK /CRAG (E) 1986 FH200C -A00 1093030 -• -- IDEC0I LATOR I r I... SNRi!('+4� (E) 1991 FH302 -A00 166662 -003 (E) I EOLDER/5TUFEER _ = � 7 I L L 1 -_- _. I Ii E 1 - li ,r j 1 1 I T1 LT-1 N X 7 .,....,,.— L I j 4,,,. . I— ' L "T (E) ( 1991 FH302C -A00 170120 -001 166662 -008 Fl-IC 302 A00 1986 FH200C -A00 (E) 109303C I - - - - - I L.. TAPE CARTS I CRAC re w LJ_. EOATA 3.8SE -2ART • (E) 1991 FH302 -A00 166662 -008 I j (E) PROVIDE NEW DISCONNECT KNOB 109303M (E) (E) 1986 F1-1200C -A00 109303A (E) 1991 166662 -005 PLAN NORTH I L L SCALE: 1 /8" = 1. -0" 1666602 -001 (E) \ L \ NEW SIEMENS CONTROL PANEL (BY GROUP HEALTH & SIEMENS) CONTACT GRAIG ROLPH ® GROUP HEALTH FLOOR PLAN LA v o \ I LI - - ■ CC TABLE \ J 1990 F1-1302C -ADO 157100 -003 f N I 109303) (E) F1-1302C -A00 FH302C -A00 109303K MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION (E) 109303F / A (E) 109303H (E) � 109303) FH302C --A00 (E) 1989 FH302C -A00 149492A (E) \ / 1990 FH302C- ADO 157100 -002 1990 FH3O2C -A00 157100-001 CRAC (E) 15 ) 1990 FH302C -A00 (E) 157100 --002 CRAC UNITS LEGEND PERMANENT 1991 TEMPORARY 4,••••••••■4 •••••••••• CRAC UNITS MOVE CRAC -18 TO NEW LOCATION. MOVE CRAC-17 TO NEW LOCATION. PHASE III FLAG NOTES * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -18. PROVIDE ELECTRICAL, START UNIT AND PLACE IN OPERATION. SWITCH LOCATIONS OF CRAC -34 WITH CRAC -12. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC-34. MIANTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC-34 TO DDC SYSTEM. RE -USE EXISTING WIRING. PROVIDE SERVICE ON CRAG UNITS 5, 14, 16, 10, 11, 17, 12. CONTRACTOR TO PROVIDE SERVICE ON EACH UNIT PRIOR TO RELOCATING. SERVICE SHALL INCLUDE THE FOLLOWING: A. FLUSH COOLING COIL WITH DE- SCALER. B. PRESSURE TEST COOLING COIL AT 100 PSI FOR 24 HOURS. C. REPLACE SHEAVES & TEST MOTOR. D. REPLACE FAN BELTS. E. REPLACE FAN BEARINGS. F. REPLACE CONTROL VALVE. G. TEST ELECTRICAL CONTRACTORS. H. RUN FAN AND CHECK BEARINGS. I. VISUALLY INSPECT CONTACTORS. J. CHECK CONTROLS. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -17. PROVIDE ELECTRICAL, START UNIT AND PLACE IN OPERATION, SWITCH LOCATIONS OF CRAC -9 WITH CRAC -11. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -9. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -11 TO DDC SYSTEM. RE -USE EXISTING WIRING. ONLY AFTER CRAC -9 IS UP AND IN OPERATION, SWITCH LOCATIONS OF CRAC -8 WITH CRAC -10. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC -10. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC -10 TO DDC SYSTEM. RE -USE EXISTING WIRING. ONLY AFTER CRAC-10 IS UP AND IN OPERATING, MOVE CRAC-17 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC-17. PROVIDE TEMPORARY ELECTRICAL, START UNIT AND PLACE IN OPERATON. ONLY AFTER CRAC-17 IS UP AND IN OPERATION, SWITCH LOCATIONS OF CRAC-7 WITH CRAC -16. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC-16. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALMM FROM CRAC-16 TO DDC SYSTEM. RE-USE EXISTING WIRING. ONLY AFTER CRAC-16 IS UP AND IN OPERATION, SWITCH LOCATIONS OF CRAC-6 WIThl CRAC-12. CONNECT ELECTRICAL AND CHILLED WATER TO CRAC-34. MAINTAIN EXISTING LEAK DETECTION SYSTEM & CONNECT TROUBLE ALARM FROM CRAC-12 TO DDC SYSTEM. RE-USE EXISTING * ADD TEMPORARY HOSE EITHER UNDER FLOOR THROUGH MAIN AISLE OR OVER CEILING THROUGH MAIN AISLE. RECEIVED CITY OF TUKWILA COMPUTER RACK r . 4- U T k • - - , - , 1 . _ _ _ _ _., 1 I ._ om.:._ =.. \: r te._.._ ._ ..._.... !! i (E) (E) 1991 FH302 -AOO 166662 -003 FOLDER /STUFFER DECOLLATO.R 1 I SHRINK 7 I KI- L_.L_.I._.�L_4_�.- .�...J - 1 (E) 166662 -008 FHC 302 A00 1991 FH302C -A00 170120 -001 1986 FH200C -A00 (E) 109303C i TAPE CARTS 1 I —_ 1 j DATA 15I (E) 1991 FH302 -A00 166662 -008 f —� I CAKE mle rksi ' r U, 0 C7 CD 1991 FH302 -A00 166662 002- Lin (E) (E) 7 (E) 1991 166662-005 PLAN NORTH IC5 ICI L 1 , COUNTER (E) 1666602 -004 SIDE PANEL MISSING SITTING ON A PALLET FHC 302 A008 109303F ,\ r I II • NEW SIEMENS CONTROL PANEL (BY GROUP HEALTH & SIEMENS) CONTACT GRAIG ROLPH @ GROUP HEALTH 1 CRAC (E) 19 1666602 -001 I� CONSOLES (3) (E) C L 11 L 1 W 0 FLOOR PLAN - HVAC SCALE: 1/r = 1' -0" Q TABLE 1 1 I , J —15 —I(51 - FH3O2C -A00 157100 -003 1990 FH302C -A00 157100 -002 iF 1990 FH302C -A00 157100 -003 (E) 1990 FH302C -A00 157100 -002 -MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION (E) 1986 109303I -- -_. { f1- ) \ fi 3 SERVICE LOCATION OF CRAG -3, CRAC -4 & CRAG- 1A(FH2OOC -A00 (E) 109303J FH302C -A00 �• f 1989 FH302C -A00 149492A (E) 109303J (E) FH302C -A00 1990 FH302C -A00 157100 -001 (E) • t ' \ 1 _ — \ (E) / CRAG 7 � PERMANENT 1991 TEMPORARY CRAC UNITS FH3O2C -A00 109303K LEGEND Vi WA � • i • i • i 4 •i • + .... ∎••∎ CRAC UNITS PHASE IV FLAG NOTES MOVE CRAC -17 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -17. PROVIDE ELECTRICAL, START UNIT AND PLACE IN OPERATION. MOVE CRAC -3 & CRAC -4 IN SEQUENCE TO NEW TEMPORARY SERVICE LOCATION. PROVIDE SERVICE ON CRAC -3 & CRAC -4. SERVICE SHALL INCLUDE THE FOLLOWING: A. FLUSH COOLING COIL WITH DE- SCALER. B. PRESSURE TEST COOLING COIL AT 100 PSI FOR 24 HOURS. C. REPLACE SHEAVES & TEST MOTOR. D. REPLACE FAN BELTS. E. REPLACE FAN BEARINGS. F. REPLACE CONTROL VALVE. G. TEST ELECTRICAL CONTRACTORS. H. RUN FAN AND CHECK BEARINGS. I. VISUALLY INSPECT CONTACTORS. J. CHECK CONTROLS. AFTER COMPLETION OF SERVICE RELOCATE CRAC -3 & CRAC -4 TO ORIGINAL LOCATION IN SEQUENCE. RECONNECT ELECTRICAL, CHILLED WATER & TROUBLE ALARM. ONLY AFTER CRAC -3 & CRAC -4 ARE IN OPERATION MOVE CRAC -17 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAG -17. PROVIDE ELECTRICAL START UNIT AND PLACE IN OPERATION. MOVE CRAC-- 1A(FH2OOC -A00) TO NEW TEMPORARY SERVICE LOCATION. PROVIDE SERVICE ON CRAC- 1A(FH200C -A00). SERVICE SHALL INCLUDE THE FOLLOWING: A. FLUSH COOLING COIL WITH DE- SCALER. B. PRESSURE TEST COOLING COIL AT 100 PSI FOR 24 HOURS. C. REPLACE SHEAVES & TEST MOTOR. D. REPLACE FAN BELTS, E. REPLACE FAN BEARINGS. F. REPLACE CONTROL VALVE. G. TEST ELECTRICAL CONTRACTORS. H. RUN FAN AND CHECK BEARINGS. I. VISUALLY INSPECT CONTACTORS. J. CHECK CONTROLS. AFTER COMPLETION OF SERVICE RELOCATE CRAC- 1A(FH200C -A00) TO ORIGINAL LOCATION, RECONNECT ELECTRICAL CHILLED WATER & TROUBLE ALARM. ONLY AFTER CRAC -1 IS UP AND OPERATING, MOVE CRAC -17 TO NEW LOCATION. * ADD TEMPORARY HOSE EITHER UNDER FLOOR THROUGH MAIN AISLE OR OVER CEILING THROUGH MAIN AISLE. RECEIVED CITY OF TUKVVI LA SEP 0 7 2007 REVISIONS Consulting Engineers "Ve) 19015 36th Ave. W. Suite A Lynnwood, Wa. 98036 • (425) 774 -3829 FAX (425) 672 -2084 . 6°°.°1. 7 -- ( 1 1 I I DATE : 08/30/07 SCALE : AS SHOWN DRAWN: GLK CHECKED: C. WRIGHT ..5 ? fi , 1 411 \ 5' /l 'Nt %. .. . EXPIRES 7/1 2/08 M2 07-043 \ • r . 4- U T k • - - , - , 1 . _ _ _ _ _., 1 I ._ om.:._ =.. \: r te._.._ ._ ..._.... !! i (E) (E) 1991 FH302 -AOO 166662 -003 FOLDER /STUFFER DECOLLATO.R 1 I SHRINK 7 I KI- L_.L_.I._.�L_4_�.- .�...J - 1 (E) 166662 -008 FHC 302 A00 1991 FH302C -A00 170120 -001 1986 FH200C -A00 (E) 109303C i TAPE CARTS 1 I —_ 1 j DATA 15I (E) 1991 FH302 -A00 166662 -008 f —� I CAKE mle rksi ' r U, 0 C7 CD 1991 FH302 -A00 166662 002- Lin (E) (E) 7 (E) 1991 166662-005 PLAN NORTH IC5 ICI L 1 , COUNTER (E) 1666602 -004 SIDE PANEL MISSING SITTING ON A PALLET FHC 302 A008 109303F ,\ r I II • NEW SIEMENS CONTROL PANEL (BY GROUP HEALTH & SIEMENS) CONTACT GRAIG ROLPH @ GROUP HEALTH 1 CRAC (E) 19 1666602 -001 I� CONSOLES (3) (E) C L 11 L 1 W 0 FLOOR PLAN - HVAC SCALE: 1/r = 1' -0" Q TABLE 1 1 I , J —15 —I(51 - FH3O2C -A00 157100 -003 1990 FH302C -A00 157100 -002 iF 1990 FH302C -A00 157100 -003 (E) 1990 FH302C -A00 157100 -002 -MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION (E) 1986 109303I -- -_. { f1- ) \ fi 3 SERVICE LOCATION OF CRAG -3, CRAC -4 & CRAG- 1A(FH2OOC -A00 (E) 109303J FH302C -A00 �• f 1989 FH302C -A00 149492A (E) 109303J (E) FH302C -A00 1990 FH302C -A00 157100 -001 (E) • t ' \ 1 _ — \ (E) / CRAG 7 � PERMANENT 1991 TEMPORARY CRAC UNITS FH3O2C -A00 109303K LEGEND Vi WA � • i • i • i 4 •i • + .... ∎••∎ CRAC UNITS PHASE IV FLAG NOTES MOVE CRAC -17 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAC -17. PROVIDE ELECTRICAL, START UNIT AND PLACE IN OPERATION. MOVE CRAC -3 & CRAC -4 IN SEQUENCE TO NEW TEMPORARY SERVICE LOCATION. PROVIDE SERVICE ON CRAC -3 & CRAC -4. SERVICE SHALL INCLUDE THE FOLLOWING: A. FLUSH COOLING COIL WITH DE- SCALER. B. PRESSURE TEST COOLING COIL AT 100 PSI FOR 24 HOURS. C. REPLACE SHEAVES & TEST MOTOR. D. REPLACE FAN BELTS. E. REPLACE FAN BEARINGS. F. REPLACE CONTROL VALVE. G. TEST ELECTRICAL CONTRACTORS. H. RUN FAN AND CHECK BEARINGS. I. VISUALLY INSPECT CONTACTORS. J. CHECK CONTROLS. AFTER COMPLETION OF SERVICE RELOCATE CRAC -3 & CRAC -4 TO ORIGINAL LOCATION IN SEQUENCE. RECONNECT ELECTRICAL, CHILLED WATER & TROUBLE ALARM. ONLY AFTER CRAC -3 & CRAC -4 ARE IN OPERATION MOVE CRAC -17 TO NEW LOCATION. * PROVIDE TEMPORARY 2" HOSE RATED FOR 100 PSI TO CRAG -17. PROVIDE ELECTRICAL START UNIT AND PLACE IN OPERATION. MOVE CRAC-- 1A(FH2OOC -A00) TO NEW TEMPORARY SERVICE LOCATION. PROVIDE SERVICE ON CRAC- 1A(FH200C -A00). SERVICE SHALL INCLUDE THE FOLLOWING: A. FLUSH COOLING COIL WITH DE- SCALER. B. PRESSURE TEST COOLING COIL AT 100 PSI FOR 24 HOURS. C. REPLACE SHEAVES & TEST MOTOR. D. REPLACE FAN BELTS, E. REPLACE FAN BEARINGS. F. REPLACE CONTROL VALVE. G. TEST ELECTRICAL CONTRACTORS. H. RUN FAN AND CHECK BEARINGS. I. VISUALLY INSPECT CONTACTORS. J. CHECK CONTROLS. AFTER COMPLETION OF SERVICE RELOCATE CRAC- 1A(FH200C -A00) TO ORIGINAL LOCATION, RECONNECT ELECTRICAL CHILLED WATER & TROUBLE ALARM. ONLY AFTER CRAC -1 IS UP AND OPERATING, MOVE CRAC -17 TO NEW LOCATION. * ADD TEMPORARY HOSE EITHER UNDER FLOOR THROUGH MAIN AISLE OR OVER CEILING THROUGH MAIN AISLE. RECEIVED CITY OF TUKVVI LA SEP 0 7 2007 I I /' 1 1 _ - -J ._ "_.. ...._...—_-- --- I 1 e r 1 II h- _J - 1 I j r ._.._.1L1 7 t II i I % r / • V / r % i l '''3 / /. /J ' � / L `/ 1 /, / j r �I I (E) 1991 FH302 -A00 166662 -003 r11 (E){ 1986 ! FH200C -A00 109303D 1DECDLLA;O-R + .4.4 I i \\ 1 i I \ I ` L i \ r E.- 1 IT T T=7:::-7.=;--7- FOLDER / STUFFER 1 i ! I e I SHRINKWRAF i (E) 7 11 I Ij I II'1 (E) 166662 -008 FHC 302 A00 CRAC 27 1991 FH302C --A00 170120 -001 8 i I 1989 FH302C -A00 14949A (E) TAPE CARTS I U, w a DAT SEc2ARTS i r r 1 . CAKE RACK CAKE RACK CAKE RACK 1 II CAKE RACK 0 U (E) 1991 FH302 -A00 166662 -008 -I DESK w (E) 1986 FH200C -A00 109303A r - '1 IN I° 1 J 0 1991 FH302 -ADO 166662 -002 1 4 II LID L__ 1991 166662 -005 1 PLAN NORTH — 1 COUNTER (E) 1666602 -004 SIDE PANEL MISSING SITTING ON A PALLET FHC 302 A008 FLOOR PLAN - HVAC \\ SCALE 1/8" = 1' -0 NEW SIEMENS CONTROL PANEL (BY GROUP HEALTH & SIEMENS) CONTACT GRAIG ROLPH ® GROUP HEALTH CRAG (E) 1666602- -001 L (E) 109303F L w L ' { T , \\\ J, (E) CRAC 12 R - -- 109303H \, TABLE L— — K51 1990 FH302C -A00 157100 -003 l � - r 1990 F1-1302C-ADO 157100 -002 MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION (E) 1990 FH302C -A00 157100 -002 (E) ( CRAC 9 1986 1093031 (E) 109303J FH302C -A00 1986 FH2OOC -A00 (E) 109303C —f � CRAG 109303) (E) FH3D2C -A00 1990 FH302C --A00 157100 -001 (E) -.r L- —i- 1 \\ \ \\--- -A\ \\:\ (E) $ (E) 109303E LEGEND PERMANENT 1991 CRAC UNITS FH302C -A00 109303K PHASE V FLAG NOTES PROVIDE PERMANENT 1 -1/2" CHILLED WATER PIPING UNDER FLOOR TO CRAC -18. CONNECT ELECTRICAL & CHILLED WATER TO CRAC -18. PROVIDE NEW LEAK DETECTION SYSItM & CONNECT TROUBLE ALARM TO DDC SYSTEM. COORDINATE EXACT LOCATION OF DOS INTERFACE WITH OWNER (CRAIG ROLF). NEW LEAK DETECTION SYSTEM SHALL BE VERIS MP SERIES WITH 30' SENSING CABLE. INTER CONNECT TO DDC SYSTEM. RECEIVED CITY OF TUKWILA SEP 0 7 2007 dcnivu I Lo r..111 11R COMPUTER RACK REVISIONS Consulting Engineers I -V 19015 36th Ave. W. Suite A Lynnwood, Wa. 98036 (425) 774 -3829 FAX (425) 672 -2084 P —/(a.--- 1 1 DATE : 08130107 SCALE: AS SHOWN DRAWN: GLK CHECKED: C. WRIGHT \5 .. T4? oY viA8t-tt _ 1 I w r � ` ` EXPIRES 7/12/08 M213 07 -043 N I I /' 1 1 _ - -J ._ "_.. ...._...—_-- --- I 1 e r 1 II h- _J - 1 I j r ._.._.1L1 7 t II i I % r / • V / r % i l '''3 / /. /J ' � / L `/ 1 /, / j r �I I (E) 1991 FH302 -A00 166662 -003 r11 (E){ 1986 ! FH200C -A00 109303D 1DECDLLA;O-R + .4.4 I i \\ 1 i I \ I ` L i \ r E.- 1 IT T T=7:::-7.=;--7- FOLDER / STUFFER 1 i ! I e I SHRINKWRAF i (E) 7 11 I Ij I II'1 (E) 166662 -008 FHC 302 A00 CRAC 27 1991 FH302C --A00 170120 -001 8 i I 1989 FH302C -A00 14949A (E) TAPE CARTS I U, w a DAT SEc2ARTS i r r 1 . CAKE RACK CAKE RACK CAKE RACK 1 II CAKE RACK 0 U (E) 1991 FH302 -A00 166662 -008 -I DESK w (E) 1986 FH200C -A00 109303A r - '1 IN I° 1 J 0 1991 FH302 -ADO 166662 -002 1 4 II LID L__ 1991 166662 -005 1 PLAN NORTH — 1 COUNTER (E) 1666602 -004 SIDE PANEL MISSING SITTING ON A PALLET FHC 302 A008 FLOOR PLAN - HVAC \\ SCALE 1/8" = 1' -0 NEW SIEMENS CONTROL PANEL (BY GROUP HEALTH & SIEMENS) CONTACT GRAIG ROLPH ® GROUP HEALTH CRAG (E) 1666602- -001 L (E) 109303F L w L ' { T , \\\ J, (E) CRAC 12 R - -- 109303H \, TABLE L— — K51 1990 FH302C -A00 157100 -003 l � - r 1990 F1-1302C-ADO 157100 -002 MAIN AISLE MUST BE CLEAR FOR DELIVERY OF EQUIPMENT DURING CONSTRUCTION (E) 1990 FH302C -A00 157100 -002 (E) ( CRAC 9 1986 1093031 (E) 109303J FH302C -A00 1986 FH2OOC -A00 (E) 109303C —f � CRAG 109303) (E) FH3D2C -A00 1990 FH302C --A00 157100 -001 (E) -.r L- —i- 1 \\ \ \\--- -A\ \\:\ (E) $ (E) 109303E LEGEND PERMANENT 1991 CRAC UNITS FH302C -A00 109303K PHASE V FLAG NOTES PROVIDE PERMANENT 1 -1/2" CHILLED WATER PIPING UNDER FLOOR TO CRAC -18. CONNECT ELECTRICAL & CHILLED WATER TO CRAC -18. PROVIDE NEW LEAK DETECTION SYSItM & CONNECT TROUBLE ALARM TO DDC SYSTEM. COORDINATE EXACT LOCATION OF DOS INTERFACE WITH OWNER (CRAIG ROLF). NEW LEAK DETECTION SYSTEM SHALL BE VERIS MP SERIES WITH 30' SENSING CABLE. INTER CONNECT TO DDC SYSTEM. RECEIVED CITY OF TUKWILA SEP 0 7 2007 dcnivu I Lo r..111 11R COMPUTER RACK