Loading...
HomeMy WebLinkAboutPermit M07-206 - WESTFIELD SOUTHCENTER MALL - RACHA THAI AND ASIAN KITCHENRACHA THAI & ASIAN KITCHEN 1150 SOUTHCENTER MALL M07 -206 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 1150 SOUTHCENTER MALL TUKW Contact Person: Name: KEITH TU Address: 505 S LANDER ST , SEATTLE WA Contractor: Name: GREAT SUN CORP Address: 505 S LANDER ST , SEATTLE WA Contractor License No: GREATSC951D1 DESCRIPTION OF WORK: INSTALL (2) COMMERCIAL KITCHEN TYPE I GREASE HOODS (22' -10" AND 24'), (2) EXHAUST FANS, AND (2) TEMPERED MAKE UP AIR UNITS ALONG WITH RELATED DUCT WORK FOR ALL FANS. Value of Mechanical: $60,000.00 Type of Fire Protection: Cityf Tukwila RACHA THAI & ASIAN KITCHEN 1150 SOUTHCENTER MALL , TUKVVILA WA WEA SOUTHCENTER LLC 11601 VVILSHIRE BLVD , LOS ANGELES CA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 4 0 0 0 0 2 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 683 -1414 Phone: 206 329 -8027 Expiration Date: 03/21/2009 M07 -206 04/09/2008 10/06/2008 Fees Collected: $638.50 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP/ 1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -206 Printed: 04 -09 -2008 Permit Center Authorized Signature: Print Name: doc: IMG10 /06 \rr' City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us oki C/((i"/ Permit Number: M07 -206 Issue Date: 04/09/2008 Permit Expires On: 10/06/2008 Date: i5 J cM ! fb I hereby certify that I have read and ex�ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the perform e of work. I am authorized to sign and obtain this mechanical permit. , ! Signature: .�� Date: ` — 9 "� 0P This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -206 Printed: 04 -09 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 10: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1150 SOUTHCENTER MALL TUKW RACHA THAI & ASIAN KITCHEN PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -206 ISSUED 09/27/2007 04/09/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until fmal inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: An approved automatic fire - extinguishing system is required for this project. 13: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire- extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire- extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 14: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) M07 -206 Printed: 04 -09 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: All new automatic fire- extinguishing systems and all modifications to existing automatic fire- extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 16: Local U.L. central station supervision is required. (City Ordinance #2051) 17: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -206 Printed: 04 -09 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond - 10/06 Date: M07 -206 Printed: 04 -09 -2008 Site Address: Name: e fr w (, CITY OF TUKWILI„,,,, Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cLtukwila.wa.us Mailing Address: Co 5 - LANs 574 • E -Mail Address: F e 5 re.,,7- • 04cayp . �`✓t Company Name: 4y/t t 7" 5 j't (oi9 . Mailing Address: cc) 6 5. G - r�t.✓t�,lcr� " < Contact Person: /,`.r(� 7 E - Mail Address: -t-a- Y44.7 /N w ✓v- 4-)+'Vl Contractor Registration Number: a te/f (`6G 9 112,D2 Company Name: 4-G " 1 90,1 h Mailing Address: 3 3/ l A'(h,✓iio P (. 5 Contact Person: E -Mail Address: Q:tApplications\Fonns- Applications On Line \3-2006 - Mechanical Permit Application.doc Revised: 42006 bh MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 2-(f G 3 t,4 . e- 0.'wit/ /10 I ( Suite Number: Tenant Name: 7 pAGGA 77 a i x,45 ;cwi /t,'C/ -tom New Tenant: a .... Yes 0 ..No Property Owners Name: t4 /& 1.Fi eii eA $o t, -t, . -- A a ( / Mailing Address: / 16 J ( (N' /ti ; vt- -. B / g Tkov- L. / ,/ City state Floor: 7<)‘ 5 Zip CONTACT PERSON' who do we contact when your permit is ready to be issue Day Telephone: ) 7 ,6 ��� /y/ fr-t- i L(/.J ( City State Zip Fax Number: ,)-b/9 — -CJ — 7 9 MECHANICAL CONTRACTOR INFORMATION r�l3 City State Zip Day Telephone: jesg -c...3 -1 tj ( Fax Number: 06 — 3c 1 -4 ` 7f '"l Expiration Date: C 5/D 5( ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Recor , 5(11 4 C 444 f � � 4l4/ City State Zip Day Telephone: et 06- ( 7 81 E -Mail Address: Fax Number: ENGINEER OF RECORD All " plans must be, wet, stamped by Engineer of Company Name: Mailing Address: Zip Contact Person: City Day Telephone: Fax Number: State Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct ',2, Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM L A Incinerator — Comm/Ind Other Mechanical Equipment if Valuation of Project (contractor's bid price): $ 60 DO 0 Scope of Work (please provide detailed information): l (b--1 lv �i /9 , y ') Use: Residential: New .... ❑ Commercial: New ...r^ BUILDING OWNE GENT: Signature: Print Name: Mailing Address: I Date Application Accepted: 5 5- Gc- , - 01 v-1A--- Q:Wpplications\Fonns- Applications On Line3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Replacement .... ❑ Replacement .... ❑ Indicate type of mechanical work being installed and the quantity below: ,-� 6iv vV -v G (7,,J: F S / £ 72 Fuel Type: Electric ❑ Gas ... Other: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO. APPLY FOR THIS PERMIT. Date: � 7 Day Telephone: c ' — 6 E3--/ r--( / City State Zip Date Application Expires: _ _ (t Staff Initials: ( Page 2 of 2 Parcel No.: 2623049023 Permit Number: M07 -206 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/27/2007 Applicant: RACHA THAI & ASIAN KITCHEN Issue Date: Receipt No.: R07 -02114 Initials: JEM Payment Date: 09/27/2007 01:25 PM User ID: 1165 Balance: 50.00 Payee: GREAT SUN CORPORATION TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Payment Amount: $638.50 Amount Payment Check 3617 638.50 Account Code Current Pmts 000/322.100 516.80 000/345.830 121.70 Total: $638.50 329? 09/2 ,,710 TOTAL t'T den: Reneint -OR Printer: 09 -27 -7007 Project: Type of Inspection: Address: 1 f 50 M4I1 Date Called: Special Instructions: Date Wanted: 7, , I t - P a. m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 2 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Pir r oe i trie (Inspector: r 07 -„2iJ -C El $60.00 Ffi_TNSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: II Si— A NA; tt t c flee" /2_ t o .4,01-t< N 01 si / on a Ft'- ety,%l ,, e...1$ 5,5,c fo..15 Date Called: Special Instructions: Date Wanted: �_ / ms=s. - Pi» .1 ? L f frn 6 , 11 PI P /7trO.n ii.y/ afeet e ON r. PJirr 25 (r -rz.00L fI. et . Projec(u th,. `, Type of Inspection: �♦ r , it4` Address: �� /' 1150 P Date Called: Special Instructions: Date Wanted: �_ / , i Requester: Phone No: I 14 20 I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Sou B lvd.. #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Approved per applicable codes. El Corrections required prior to approval. 'Inspects Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: ..... 14 4cl. —r-k. j of Inspection s /iwx..0_. S A.c., 4 -at ow n Address: )/ ! # cc- Date Called: Special Instructions: Date Wanted: if' b / O F a m. Requester: Phone No: it Yklo 7 - 2 - o INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. NUICorrections required prior to approval. COMMENTS: fits— need mr'Gi-an,cQ Pr in ©R- fie gee. -1--©{ vA; kS h r) 4 La te) or 'Id/ 1%41 rr7-P je- Inspecto ? (Date: 7 116 / $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: LI Approved per applicable codes. Corrections required prior to approval. COMMENTS: p/ 6 re45e. 44 (2P/M0 are See. Ktet 71.0. tes Cey0f Ittk000k 5V 4t) -C tOrAy Inspectora p r ate: 4A ,, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (20)431-3670 Project: 4X A rh4 Address: g Special Instructions: Type of Inmection: o I/ Date Called: Date Wanted: S-- Requester: Phone No: - 353 -/26., LI $58 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Date: Receipt No.: COMMENTS: Type of Inspection: 1-106D -4V-1 Pi riNe 40 Address: M ) ni 4 fl v3-e_ t d iNu spe 4 1 6 -r 5,,,, . LAATe -ik ,f,i N,14-1 Date Wanted: , ,v) i. Requester: r, ')()-(- Phone No: A NIA),-,(Le ...----.....\ ........„... Prod f14,9C Type of Inspection: Address: M ) ni 4 fl Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: Rec INSPECTION NO. Pt No.: INSPECTION RECORD Retain a copy with permit D t 'Date: PERMIT NO. r- CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 ID Approved per applicable codes. El Corrections required prior to approval. s e o : A AA A 11 'NA A tkiJ bk-ty 0 0 REINSPECTION FE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. COMMENTS: Type of Inspection: g' r, tl /I It Address: I I C O 5,d4 e". P I I & ad 1 I/ fi ;‘, ki'let fo L.-,44., I Z-re — 1:F" ,,,, 1.1 I- rv,- itt -t ,,..,,,,e-f--- _- Requester: Phone No: 2 , 35_3 WQ Project: g4C 4 If Il ,k-,- lel., 4. Type of Inspection: g' r, tl /I It Address: I I C O 5,d4 e". P I I Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: 2 , 35_3 WQ I INSPECTION NO. El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit NO2 - 2.o6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 13 . Corrections required prior to approval. $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: R i11 I Lc4 Sprinklers: Type of Inspection: M ecti Fnc, Address: / Suite #: , M I , Contact Person: Erik � 7 ! 4✓ Hm Special Instructions: Phone No's Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT kwila, Wa. 98188 206 -575 -4407 Z Approved per applicable codes. COMMENTS: AA ock4h,Zc Word /Inspection Record Form.Doc l.� Inspector: Date: '7— / 1_ Hrs.: H $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. 1/13/06 c, 0Y v' — lq?- PERMIT NUMBERS rrections re • ired prior to approval. ry.A.A d LI T.F.D. Form F.P. 113 , • p • t MUM 411MIIIV GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING , i CONSTRUCTION TESTING & INSPECTION June 20, 2b' RECEIVED Dear Mr. Ta, JUN 3 0 2008 COMMUNITY DEVELOPMENT Mr. Keith H. Ta Great Sun Corp. 505 S. Lander Street Seattle, WA 98134 RE: Special Inspection Racha Project Tukwila, WA In accordance with your request and authorization, our firm performed special inspections for the above - referenced project. The inspections were performed by our inspectors on May 30, 2008. Copies of our inspector's field reports are attached. Unless otherwise indicated, the structural activities noted on the attached daily field reports were in accordance with the approved project plans and specifications. A guarantee that the contractor has necessarily constructed the structure in full accord with the plans and specifications is neither intended nor implied. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC aaii & ASSOCIATES, INC. Kathryn E. Gordon Project Manager Puyallup Division CC: City of Tukwila Offices Serving The Western United States KA No. 066 -08089 Permit No. M07 -206 922 Valley Avenue NW Suite 101 • Puyallup, Washington 98371 • (253) 939 -2500 • Fax: (253) 939 -2556 08089 DFR Template azan:' A CONTRACTOR: Permit No.: 7 DATE: _. t ti PROJECT / PROJECT: Q LOCATION: .Of, t 0 2 KRAZAN PROJECT MANAGER: � �` GEOTECIINICAL ENGINEERING • .ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION Superintendent /Representative: 4231 Foster Ave: Bakersfield, C4 93308 (805) 633 -2200 ❑ ` STRUCTURAL STEEL FIELD / .S4( 3P . WELDING _ : .0 V.T. d MATERIAL ID .❑ U.T." . ❑ M.T. . .❑ P.T. Item(s) inspected: 0, . Location: /'''r ! Welder qualification /certification`verified for: ❑ Position: FLAT VERTICAL _ 'HORIZONTAL OVERHEAD ❑ Filler Metal: ❑ Process: SMAW FCAW GMAW SAW ❑ Other: • Weld Type: FILLET C.P. P.P. PLUG ❑ Other: ❑ Weld Size :. 3/1 Y." 5/16" .. % ❑ Other: E Codes:. AWS AISC " TITLE 21 TITLE 24 UBC ASME I a°"-e--,0 ,r "s4E ❑ NOTES ❑ DISCREPANCIES ❑ % COMPLETE A 4%.-71...A _ --31 ` I ii ,- ?i'- � .o a (2 . •5 / i? 4r_�I 5 • '; ,4 COPIES TO : /- , To the best of my knowledge, the above WAS / AS NOT performed in accordance with the ap a ed plans, specifications, and re ulatory requirement: 25418 74th Ave. S Kent, WA 98032 (253) 854- 1330 Technician: 215 West Dakota Avenue Clovis, CA 93612 11 ATT Tr1 IKAF HFFT LO.R.: PRESENT AT SITE: DSA File(Appl. No. . OSHPD No. WEATHER: "79;2 /7 • TEMP: 6, 550 Parrott St. #1 San Jose, CA 95112 (408) 271 -2200 _4 ' 123 Commerce Circle Sacramento, CA 95815 (916) 564 -2200 & ASSOCIATES, INC. Dear Mr. Ta, GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION June 9, 2008 RECEIVED 'JUN 1'3 2006 Mr. Keith H. Ta t p U ZAT Great Sun Corp. 505 S. Lander Street Seattle, WA 98134 RE: Special Inspection Racha Project Tukwila, WA In accordance with your request and authorization, our firm performed special inspections for the above - referenced project. The inspections were performed by our inspectors on June 4, 2008. Copies of our inspector's field reports are attached. Unless otherwise indicated, the structural activities noted on the attached daily field reports were in accordance with the approved project plans and specifications. A guarantee that the contractor has necessarily constructed the structure in full accord with the plans and specifications is neither intended nor implied. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC Kathryn E. Gordon Project Manager Puyallup Division CC: City of Tukwila Offices Serving The Western United States KA No. 066 -08089 Permit No. M07 -206 922 Valley Avenue NW Suite 101 • Puyallup, Washington 98371 • (253) 939 -2500 • Fax: (253) 939 -2556 08089 DFR Template M (razari 8 c A S S O C I A T E S, I N c. FIELD REPORT NO.: 8089DFR060408 -gn GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE: 6-4-08 PROJECT #: 066 -08089 PROJECT: Racha Project LOCATION: #1150 South Center Mall KRAZAN PROJECT MANAGER: K.E.G. Structural Steel CONTRACTOR: Great Sun PERMIT NO: M07 -206 INSPECTOR: George Naill / John Maggard JURISDICTION: City of Tukwila WEATHER: Cloudy Temp: 55 F Arrived on site as requested by the contractor to perform Structural Steel Re- inspection in conformance to project plans and specs. 1) Met with the contractor to verify inspection and review plans. 2) Performed visual re- inspection of Grease Duct welded connection previously rejected on report dated 5 -30-08 inspection performed per section 506.3.3.1 IBC mechanical code 2006 version. Revealed welding to be repairec and acceptable. To the best of my knowledge, the above WAS ® / WAS NOT ❑ performed in accordance with the approved p ansjspecifications, and regulatory requiremel Superintendent/Representative: Technician George Naill Offices Serving the Western United /States Equipment/Asset Number(s): Form 1501 r.2 Effective Date: 12 -20 -07 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. pl ` r ?, a `pp oval 13 subject to err= d coruf' en doe!, r:: a he ,iL^ • -.. _ a . • •. FILE COPY Permit No. d _ .EXHASUT••DISCHARGE ADD ON EXTENSION (16 GA. GALVANIZE STEEL) - SPARK - RESISTANCE KITCHEN EXHAUST BLOWER GREASE DRAIN GREASE DIP PAN 16 GA. ALL AROUND LIQUID TIGHT WELDED GREASE DUCT Ion KITCHEN EXHAUST BLOWER S[_AI F • % = 1' - EXHAUST DISCHARGE CORRECTION LTR IL2*-- E> E> {�UVIdG Mi A•iv bAte, ;4 foil! 5. 8' HIGH SCREENING PARAPET • MOEt • • r RECEftfE[ MAR 28 2008 PERMIT CENTE • UL -762 Listed Restaurant Exhaust Appliances (YZHW) • Backward incline, nonoverloading aluminum wheels • Aluminum rub ring • Heavy gauge steel housing • Max. Inlet air temperature: 300 °F • Max. ambient temperature: 104 °F Designed for commercial kitchen exhaust or industrial applications requiring high Item No. 1WBW7 IWBW8 13 1WBX1 20 1246 1383 1608 1861 1671 1862 2176 2522 2795 3224 3562 2808 3270 3633 4203 4645 5344 6259 4164 4629 5372 5960 6876 For more information on selecting commercial kitchen exhaust & supply ventilators, see page 3936. Spark - Resistant Kitchen Exhaust Belt-Drive Blowers Wheel CFM Air Delivery ® Stalls Pressure Shown' Dia. (In.) 0.250' 0.500' 0.750' 1.00" 1.50" 2.00" 2.50' 1158 1307 1542 1802 1047 1215 1472 1744 1509 1309 1720 1559 2056 1926 2419 2311 2703 2607 3145 3062 3491 3418 2600 2354 3093 2899 3473 3312 4066 3925 4521 4393 5237 5127 6168 6075 3863 3506 4362 4057 5138 4904 5749 5537 6695 6508 922 1109 1389 1351 1783 2196 2507 2979 3342 1988 2677 3125 3782 3443 4268 3985 4604 4349 5014 4797 volumes of air at high static pressures and spark - resistant construction. Scroll can be rotated in 45° increments to 8 separate posi- tions, and has bolted access door for easy cleaning. 1' threaded drain connection point on bottom of scroll. Powder coated with gray polyester urethane. Weather hood is included and shipped in the upblast position. WARNING: Use a hazardous location motor where flammable vapors are Involved. Item Wheel Max. Blower Shalt Dimensions (In.) No. I Diameter (in.) RPM Diameter (In.)' A B C E F 6 If 1W81/4 10 2103 3/4 z 11 834 15 221 20% 111/4 111/2 1WBW81 13 2522 1 1 14 10% 161/4 241/4 221/2 141/4 14% 1 W B W 9 16 2041 11'4 17'6 121 191 30 281 171 173'. 1WBX1 ' 20 1482 1'h 211 15% 2334 3611 35 21% 211 1WBX2 i 24 1281 11 251 19 25 4534 36 26 261/4 1198 1296 1929 2290 2801 3186 1824 2631 1395 2011 2607 3018 2973 3647 4061 4538 3005 - - 3703 - 4627 3936 5309 4782 3996 6324 5908 5435 2367 2837 3173 3706 4250 4782 Saves Blower Motor Max. ® 0.750' SP 3.00" RPM HP SHP ® 5 Ft. 2015 2618 3201 3893 935 1027 1176 1295 3335 1482 1400 1670 1833 2103 1261 1384 1589 1819 2002 2292 2522 1125 1288 1418 1624 1785 1900 2041 6075 5610 5051 4330 - - 7059 6674 6238 5738 3820 - - 1W8X2 24 7824 7485 7120 6692 5672 - - 9045 8768 8452 8128 7361 6420 1081 10,813 10,580 10,339 10,072 9512 8870 8155 7188 1281 751 859 944 J K MN 201 251 31 37% 451 8% 1514 16 10% 16% 17% 121/2 20% 2111 141/4 241 25% 171 311 311 1/4 1/4 1/3 1/2 1/4 1/3 1/2 3/4 1 11 2 1/2 3/4 1 11 2 3 3 0.25 0.33 0.5 0.75 0.25 033 0.5 0.75 1 1.5 2 0.5 0.75 1 1.5 2 3 4.7 9.5 11.1 14.1 17.4 8.8 10.2 12.7 16 18.4 22 25 9.8 12.2 14.3 17.8 20 24 32 3/4 0.75 12 1 1 13.6 11 1.5 16.7 2 2 19.3 3 3 24 1 1 11.8 11 1.5 14.2 2 2 16.7 3 3 21 5 5 30 (') Performance certified is for installation type 8: free inlet, ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are in cones and are calculated per AMCA Standard 301. Outlet ratings include the effects of duct end correction. The AMCA Certified ratings Seal applies to air performance ratings only. CORRECTION Mop- Zo ROWERS te Y uew Note: Review OSHA Codes. OSHA complying guards are required when fan blades are exposed and within reach of personnel. Dayton Electric Mfg. Co. certifies that the ventilators shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. No. 1 WBW7 Industrial Dayton lECEIVED MAR 2 8 2008 PERMIT CENTE March 31, 2008 Elizabeth Montgomery 1405 Boylston Av Seattle WA 98188 RE: Request for Permit Application Extension Mechanical Permit Application No. M07 -206 Racha Thai —1150 Southcenter Mall Dear Ms. Montgomery: This letter is in response to your written request for an extension to Permit Application No. M07- 206. The Building Official has reviewed your letter and considered your request to extend the above referenced permit application. The City of Tukwila Building Division will be extending the expiration date of your permit application for an additional 90 days from the original application expiration date (through June 23, 2008) as requested. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, fifer Marshall Pei nit Technician File: Permit No. M07 -206 City of Tukwila P:\Pennit Center\Extension Letters\Pemrit Applications \ 2007%407 -206 Application Extension.doc jem Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 VI Kill - I ..V. I sVC'4VVC .4. . 141 - SO...,.. "........ ..1..4....4 ...4. From: Bob Benedicto To: Bill Rambo; Jennifer Marshall Date: 03/21/2008 11:01 am Subject: Fwd: Request for Plan Review Extension(Racha Thai) CC: Marcia Peddicord O.K. to extend mechanical permit application for Racha Thai - M07 -206 - 90 days. o72/4a . 6t - rXclV,lN v March 21, 2008 Bob Benedicto Building Official Department of Community Development 6300 Southcenter Blvd Tukwila, WA 98188 RE: RachaThai, 1 150 Southcenter Mall,Tukwila,WA 98188 Request for Extension of Plan Review Dear Bob: Please accept this letter as my official request to extend my Mechanical plan review ( #M07 -206) timeframe. We have not yet completely satisfied plan review comments from your office and are still working diligently with your staff to complete all requirements. Please feel free to contact me if you have questions or concerns regarding this matter at 206 - 322 -4323. Sincerely, Elizabeth Montgomery Architect Cc: Tenant Coordination WA1'E?cCEO D E S I G N S T U D I O 1405 Boylston Avenue SEATTLE. WA 98122 ! Telephone 206.322.4323 Fax 206.322.9177 E -mail: info @catchstudio.com Wchsite: www.catchstudio.com. March 7, 2008 Keith Tu 505 S Lander St Seattle WA 98134 Guy of Tukwila Department of Communiity Development Jack Pace, Director RE: CORRECTION LETTER #2 Mechanical Permit Application Number M07 -206 Racha Thai & Asian Kitchen —1150 Southcenter Mall Dear Mr. Tu, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Si; cerely, Brenda o t Permit Coordinator encl xc: File No. M07 -206 P:\Pennit Center\Correction Letters \2007 N07 -206 Correction Ltr #2.DOC wer Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: March 6, 2008 Project Name: Racha Thai & Asian Kitchen Permit #: M07 -206 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. One item of concern is meeting mechanical code clearances for the grease duct exhaust fan terminating adjacent to the upper building walls and other parapet structures. (2006 IMC 506.3.12.3) Exhaust outlets shall be located not less than 10 feet horizontally form parts of the same or contiguous buildings, adjacent buildings, adjacent property lines and air intake openings into any building and shall be located not less than 10 feet above grade. Exception: Exhaust outlets shall terminate not less than 5 feet from parts of the same or contiguous building and adjacent building, adjacent property line and air intake openings into a building where air form the exhaust outlet discharges away from such locations. Please revise the plan for the exhaust fan to show exhaust discharged shall be located 10 feet from the side of the building or structures. Or where the exhaust can be diverted away and be within 5 feet from those structural elements. This may not work with the type of exhaust fan proposed. One intake air is shown 10 feet from the exhaust fan and a large distance away from the other intake air. On solution may be to relocate the two intake air openings closer together to gain the distance clearances needed. Other building components may have some restrictions. Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. 02 -12 -2008 KEITH TU 505 S LANDER ST SEATTLE WA 98134 RE: Permit Application No. M07 -206 1150 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 09/27/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 03/25/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 03/25/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Ter Marshall 't Technician Permit File No. M07 -206 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 October 16, 2007 Keith Tu 505 S Lander St Seattle WA 98134 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M07 -206 Racha Thai & Asian Kitchen — XXX Southcenter Mall Dear Mr. Tu, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenzer service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, R aft416._ Bill Rambo Permit Technician encl xc: File No. M07 -206 City of Tukwila P:\Permit Center\Correction Letters\2007\M07 -206 Correction Lir #1.DOC wer Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: October 12, 2007 Project Name: Racha Thai & Asian Kitchen Permit #: M07 -206 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Building plan review for the restaurant TI shall be required prior to a full plan review of the mechanical plan review. 2. Additional plan details and elevations shall be required to identify those portions of the upper building construction to show where the exhaust from the kitchen hood shall not adversely affect the upper structures, tenants, openings or relative building components. Please provide plan view and any other elevation view to show mechanical exhaust shall not create a nuisance of fire hazard. (IMC 506.3.12) 3. Provide code notes on the plans Indicating compliance with current 2006 building and mechanical codes. Should there be questions concerning the above requirements, contact the Building Division at 206-431 -3670. No further comments at this time. ACTIVITY NUMBER: M07 -206 DATE: 03 -27 -08 PROJECT NAME: RACHA THAI & ASIAN KITCHEN SITE ADDRESS: 1150 SOUTHCENTER MALL _ Original Plan Submittal X Response to Correction Letter # 2 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: II i B i d') g D' I• n Public Works Complete TUES/THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Documents/routing slip.doc 2 -28.02 12 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention ❑ Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required Planning Division Permit Coordinator DUE DATE: 04-01-08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 04 -29 -08 Notation: REVIEWER'S INITIALS: DATE: Not Approved (attach comments) IT Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 - 206 DATE: 03 - - PROJECT NAME: RACHA THAI & ASIAN KITCHEN SITE ADDRESS: 1150 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # - After Permit Issued DEPARTMENTS: Building DRAW 1.4 Public Works ❑ Complete Documents/routing slip.doc 2 -28.02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP TUES/THURS R9UTING: Please Route ❑ Structural ❑ Permit Coordinator ic■ Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required Planning Division DUE DATE: 03 -06 -08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 04 -03 -08 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) d Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: ' 1 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: VlY DEPARTMENTS: Comments: Documents/routing slip.doc 2 -28-02 APPROVALS OR CORRECTIONS: UPERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -206 DATE: 09 -27 -07 PROJECT NAME: RACHA THAI & ASIAN KITCHEN SITE ADDRESS: XXX SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Fire Prevention Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IV Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Io•� Planning Division Permit Coordinator No further Review Required DATE: DATE: C DUE DATE: 10-02 -07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg El Fire ❑ Ping ❑ PW El Staff Initials: DUE DATE: 10-30-07 Approved Ti Approved with Conditions n Not Approved (attach comments) R✓ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: I l r� - t b- U - 1 Departments issued corrections: Bldg Fire El Ping El PW ❑ Staff Initials: tAAP, REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /;,)J7 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: M07-206 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 2 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: RACHA THAI AND ASIAN KITCHEN Project Address: 1150 Southcenter Mall Contact Person: Keith Tu Phone Number: 2 - 1 4 1 , Summary of Revision: IAA- 5 # d v ,47 G XAdw j RECEIVED +r o� TUKWII ✓Ef MIT CENTER • Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: Er Entered in Permits Plus on 3') ' �O \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ?v- ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # - after Permit is Issued • • ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Racha Thai & Asian Kitchen_. Project Address: XXX Southcenter Mall Sheet Number(s): \applications\ forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development &eve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us Received at the City of Tukwila Permit Center by: Eir Entered in Permits Plus on 3 - 0 S Plan Check/Permit Number: M07 -206 en M. Mulled Mayor Contact Person: Keith Tu Phone .Number: ,(�� Summary of Revision: 510 I.4 Je / ( e / (Jc kr i Gl fel t k l )fi & D T 11,0 i\ I I r e- e )C ((;z (h r a./- y t ce . "Cloud" or highlight all areas of revision including date of revision C- ". "('YOFTUKWILA MAR 0 4 2008 °EfMIT cctr tr: License Information License GREATSC95IDl Licensee Name GREAT SUN CORP Licensee Type CONSTRUCTION CONTRACTOR UBI 601984317 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 505 S LANDER ST Address 2 City SEATTLE County KING State WA Zip 98134 Phone 2063298027 Status ACTIVE Specialty 1 OTHER (SPECIFY) Specialty 2 UNUSED Effective Date 3/21/2005 Expiration Date 3/21/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date TA, KEVIN PRESIDENT 03/21/2005 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 PLATTE RIVER INS CO 41100700 03/10/2007 Until Cancelled $6,000.00 02/23/2007 ACCREDITED Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= GREATSC951 D 1 04/09/2008 1.1 16 GA. GALVANIZE SUPPORT BRACKET 3" STAINLESS STEEL FLASHING —� 16 GA, GALVANIZE GREASE DUCT DUCT TO BE CONTINUOUS TIGHT WELD BETWEEN HOOD FOR ADDED SUPPORT 1.5° METAL FASTENERS BETWEEN HOOD & SUPPORT BRACKET 3" No.10 FASTENERS BETWEEN STUD WALL & SUPPORT BRACKET (ON CENTER OFF FRAMING STUDS) NOTES: PROJECT INFORMATION: TENANT: RACHA THAI & ASIAN KITCHEN 633 SOUTHCENTER MALL TUKWILA, WA MECHANICAL DESIGNER: GREAT SUN CORP. 505 S. LANDER ST. SEATTLE, WA 98134 CONTACT: KEITH TA TEL:(206)329 -8027 TYPICAL HOOD SUPPORT DETAILS 1 • GREASE HOOD f 1 1 11 • BUSINESS OWNER: THAI FOOD INTERNATIONAL 6313 6TH AVE. SOUTH SEATTLE, WA 98108 TEL: (206)768.8883 CONTACT: KANE BUNYAKETU TEL:(206)579.7725 PROPERTY OWNER: WESTFIELD SOUTHCENTER MALL PROJECT MANAGER: JOSH KIMMEL 11601 WILSHIRE BLVD, 9TH FLOOR LOS ANGELES, CA 90025 JKIMMEL@WESTFIELD.COM TEL: (310)893.4761 GREASE ACCESS DOOR CLEAN OUT SCOPE OF WORK: INSTALL TWO 24' COMMERICAL KITCHEN (TYPE 1) GREASE HOOD, TWO EXHAUST FANS, TWO INLINE MAKE UP AIR BLOWERS, TWO ELECTRIC FURNANCES & RELATED DUCT WORK FOR ALL FANS • -fi+t • 1 1 1 ; •,( 1 i 11 11 1 • 4(1 1 I y♦ • • 1 1 ' V, ) ' "J,• 20 GA. STAINLESS '+ 1 STEEL TYPE 1 • •'f 1 �• • • • . 1. THE EXHAUST FAN & MAKE UP AIR SYSTEM WILL BE CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH FOR SAME TIME OPERATION. 2. ALL EQUIPMENT SHOWN ON THIS DRAWING SHALL BE AS SPECIFIED OR EQUAL. 3. THE PROPOSED WALL TO BE CONSTRUCTED TO MEET THE FIRE CODES FOR TYPE 1 HOOD (1 HR. FIRE RESISTIVE SHIELD). 4. STAINLESS STEEL SHEET SHALL COVER THE ENTIRE COOKING AREA. 5. ALL HOOD, DUCT JOINS, & SEAMS SHALL BE EXTERNAL GREASE TIGHT WELD. 6. EXHAUST FAN SHALL BE 40" (MIN.) DISCHARGE ABOVE ROOF. 7. MIN. DISTANCE BETWEEN EXHAUST FAN & MAKE UP AIR & ALL HVAC INTAKES SHALL BE NO LESS THAN 10'. 8. FIRE SUPPRESSION SYSTEM WILL BE UNDER SEPERATE PERMIT. 1/2" THREADED STEEL ROD „` ell , 1 _ , 4 ; 1 ' 1 r,1* " J 11 • .;( " Iyy• 1 1 ' 1 yJ;' l l l y + 4, • 20 GA. STAINLESS STEEL TYPE 1 • x 111 GREASE HOOD I '1' •:i 1 1 yJ, L 7 1 1 y , 1 t1 1Ji, Y . ' 1 1 y • CONCRETE WEDGE ANCHOR WASHER FASTENER 9 GA. BRACKET WELDED ONTO HOOD 16 GA. GALVANIZE SUPPORT BRACKET •Is WASHER MANUFACTURER: WESTERN STATES FASTENING SYSTEMS PART #: 50943 No. 14 NON- COMBUSTIBLE 1.5" HEX. WASHER SELF DRILL SCREWS FRONT SUPPORT CONCRETE WEDGE ANCHOR FASTENER y2. THREADED STEEL ROD WELDED ONTO HOOD VA A w P ALL AROUND CONTINUOUS TIGHT WELDED 16 GA. GALVANIZE GREASE DUCT ALL AROUND CONTINUOUS TIGHT WELD BETWEEN DUCT AND HOOD SYSTEM 3" STAINLESS STEEL (20 GA.) FLASH WALL FRAME 5/8" TYPE "X" FIRE RATED SHEET ROCK STAINLESS STEEL WALL w! ROXUL AFB 1' FIRE PAD FLOOR FASTENED ONTO CURB CURB WILL BE TIGHTLY WELDED TO DUCT 36 "(W)x 30 "(L)x 20"(H) 16 GA. GALVANIZE CURB 3.5" SCREWS FASTENED ONTO ROOFTOP GREASE GUTTER 4' LIGHT FILTER COOKING EQUIPMENT 3' -9" ELEVATION VIEW SCALE: %2 = 1' 6' -6° EXHAUST FAN ANCHORAGE INFO 24 GA. GALVANIZE MAKE UP AIR DUCT MAKE UP AIR VENTS 20 GA. STAINLESS STEEL (4' x 22' -10 °) TYPE I GREASE HOOD GREASE CAN 16 GA. GALVAN IZE DUCT 6=> ELEC. HEAT FURNANCE #1 INLINE MUA BLOWER #1 r I V N INLINE MUA BLOWER #2 l 1 7 i x M - w e rye �; �wCa.7�� 1L 1 w Ira L 'deo N„ (0% f .i.45 ex gel 0.47 .P „Ilr 4.PV IM' 1 ✓ a dt I fit 1st FLOOR ROOF LINE SEPARATE PERMIT REQUIRED FOR: a Mechanical ®'Electrical !P lumbing Pig City of Tukwila BUILDING DIVISION MIN. 10' EF EF /11 1} REy1SIO S No chS shall be maw to the scope Tur w �without o p approval o NOTE: Revisions will require 9 Division. -nd may include additional plan new plan fees. 4 0Io SITE / ROOF PLAN NORTH SCALE: 1/8" = 1' SCALE: 1/8" = 1' FILE COPY Permit No. Pier WOW approval b suited to en= and °Melons. the violation of my adorad code or ordnance. Receipt ofd Field Copy end admowledged: BY Date: City of Tukwila BUILDING DIVISION CORRECTION .TR# C REVIEWED FOR I E COMPLIANCE APPROVED APR - 2 2008 :& EWED MAR 042008 ()EMT CENTER Mop - 2o6 w t9 CL CL a) E W 1 CZ th CD d Cl) co VO SHEET NUMBER oc 0 v Cu N a) C, cn C) a W U) M r co FAN EQUIPMENT SCHEDULE UNIT BRAND NAME MODEL # CFM (REQUIRED) HORSE POWER S.P. LECTRICAL (VOLTAGE) /(PHASE) WEIGHT (LBS) L WA EXHAUST FAN #1 DAYTON 4YY22 10,800 5 0 -75" (208 - 230/460) / (3PH) 295 72 d.B.A. EXHAUST FAN # 2 DAYTON 4YY22 10,800 5 0.75" (208 - 230/460) / (3PH) 295 72 d.B.A. MAKE UP AIR #1 DAYTON 7H760 9,800 5 0.3" (230/460) / (3 PH) 165 68 d.BA MAKE UP AIR # 2 DAYTON 7H760 9,800 5 0.3" (230/460) / (3 PH) 165 68 d.BA ELECTRIC HEAT FURNANCE #1 REZNOR EEDU N/A N/A N/A (230/460) / (3 PH) 185 N/A ELECTRIC HEAT FURNANCE #2 REZNOR EEDU N/A N/A N/A (230/460) / (3 PH) 1 85 N/A EQUIPMENT 1. TYPE 1 HOOD SYSTEM X45 "(W) x 274 "(L)> 2. 6 BURNER RANGE <36 "(W) x 56 "(H)> 3. WORK TABLE <18 "(W) x 36 "(H)> 4. RADIANT BROILER <24 "(W) x 14 "(H)> 5. FLAT GIDDLE <24 "(W) x 14 "(H)> 6. DEEP FRYER <16 "(W) x 43 "(H)> 7. DOUBLE STOCK POT RANGE <18 "(W) x 20 "(H)> 8. RAPID PASTA COOKER <15 "(W) x 36 "(H)> STAINLESS STEEL WALL w/ ROXUL AFB 1' FIRE PAD GREASE ACCESS DOOR CLEAN OUT (ONE PER 10' & EACH TURN) STAINLESS STEEL WALL w/ ROXUL APB 1° FIRE PAD GREASE ACCESS DOOR CLEAN OUT (ONE PER 10' & EACH TURN) ALL AROUND CONTINUOUS TIGHT WELDED GREASEDUCT (16 GA. GALVANIZE STEEL) < GREASE DUCT TO SLOPE Ye PER FOOT> GREASE ACCESS DOOR CLEAN OUT (ONE PER 10' & EACH TURN) - 8' HIGH SCREENING PARAPET ROOF TOP OUTDOOR AREA • 1 MAKE UP AIR INTAKE 4" x 4" SLEEPERS 2nd FLOOR (FUTURE RETAIL SPACE) 20 GA. FLASH — MIN. 10' O FRONT VIEW (24" HOOD) SCALE: % = 1' ROOF AREA IS DEDICATED ONLY TO THIS TENANTS CONCRETE ._ WALL G S_ UP 2O'+ x R�OF AR FP�WILL C0_7 IS Q .O 2 HVAC UNITS, 2 MAKE ' TAK & 2 EXIt1AUST FANS r • GREASE ^ CAN • . GREASE ACCESS DOOR CLEAN OUT (ONE PER 10' & EACH TURN) EXHAUST FAN #1 20 GA. FLASH 20' DUCT SUPPORTS — • DUCT SUPPORTS - 24 GA. GALVANIZE MAKE UP AIR DUCT ALL AROUND CONTINUOUS TIGHT WELDED GREASEDUCT (16 GA. GALVANIZE STEEL) <GREASE DUCT TO SLOPE Ya" PER FOOT> 2nd FLOOR (FUTURE RETAIL SPACE) DUCT SUPPORTS INLINE MAKE UP AIR #1 GREASE ACCESS DOOR CLEAN OUT (ONE PER 10' & EACH TURN) 1'-8' :+ 1/2" THREADED STEEL ROD (FRONT SUPPORT) STAINLESS STEEL WALL w/ ROXUL AFB V FIRE PAD HEAT FURNANCE #1 2006 IMC 502.2.1.1 OPERATION. Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508A MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that4 makeup air is provided when ever the exhaust system is in operation. Makeup air intake opening locations shall comply with Sections 401.4 and 401.4.1. • v-4° -/ CONCRETE CEILING I 80 ® OD=MI ®aD__® e o CED=CD ® HINDGES TO BE INSTALLED ONTO EXHAUST FAN EASIER CLEANING ACCESS EXHAUST FAN #1 DUCT SUPPORTS ------ 1' -5" 11'-5' I eoe eoe ROOF TOP OUTDOOR AREA GREASE CAN —/ 22' -10' ceD MIN. 10' 1/2° THREADED STEEL ROD (FRONT SUPPORT) GREASE ACCESS DOOR CLEAN OUT (ONE PER 10' & EACH TURN) o� FRONT VIEW (22' -10" HOOD) SCALE: 1/2 =1' D T _1 J T MAKE UP AIR INTAKE 4" x 4" SLEEPERS 24 GA. GALVANIZE MAKE UP AIR DUCT 00 ,._ ® 1/2" THREADED STEEL ROD --- (FRONT SUPPORT) _/ 0 6 � 3' AIR SPACE WALL FRAME 518' TYPE X' FIRE RATED SHEET ROCK 8' HIGH SCREENING PARAPET STAINLESS STEEL WALL w/ ROXUL AFB 1" FIRE PAD CODE COMPLIANG: APPRO APR - 2 2s•. /j C i t y Ot Tukwitn -.. ILDLN AVVIS] • R C Ew r MAR 0 4 2008 PERMIT CEN i E E 0 U LZ. L 0 a' co d 2 oo ■ Q) I, 0. n a) • E I. V W L z c a) Ii SHEET NUMBER