Loading...
HomeMy WebLinkAboutPermit M07-211 - WESTFIELD SOUTHCENTER MALL - GILLY HICKSGILLY HICKS 457 SOUTHCENTER MALL M07 -211 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: ROB HUMPHREY Address: 833 SE MAIN ST #242 , PORTLAND OR Contractor: Name: HANLIN RAINALDI CONSTRUCTION Address: 6610 SINGLETREE DR , COLUMBUS OH Contractor License No: HANLIRC962NQ DESCRIPTION OF WORK: MECHANICAL FOR TI 6364200010 457 SOUTHCENTER MALL TUKW Value of Mechanical: 118,000.00 Type of Fire Protection: GILLY HICKS 457 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 5 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 320 -5030 Phone: 614 -436 -4204 Expiration Date: 07/17/2009 M07 -211 01/30/2008 07/28/2008 Fees Collected: $1,159.78 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP/ 100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 22 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 doc: IMC -10/06 M07 -211 Printed: 01 -30 -2008 Permit Center Authorized Signature: Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Qjitr 2.4 , ./ vS/y Ra Permit Number: M07 -211 Issue Date: 01/30/2008 Permit Expires On: 07/28/2008 Date: Hem-0e ' I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit • oes not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the p ce of work. I am authorized to sign and obtain this mechanical permit. Date: / —,70- o This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC - 10/06 M07 -211 Printed: 01 -30 -2008 Parcel No.: 6364200010 Address: 457 SOUTHCENTER MALL TUKW Suite No: Tenant: GILLY HICKS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: MO7 Status: ISSUED Applied Date: 10/04/2007 Issue Date: 01/30/2008 1: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 2: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 3: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and axe acceptable with the following concerns: 9: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 10: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 11: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 12: Local U.L. central station supervision is required. (City Ordinance #2051) 13: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC doc: Cond -10/06 M07 -211 Printed: 01 -30 -2008 104.2) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 17: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -211 Printed: 01 -30 -2008 Signature: Print Nam / ?QAG Jjg /A//,+Skr doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: A . Of M07 -211 Printed: 01 -30 -2008 King Co Assessor's Tax No.: Site Address: L i I D VT 4 t C t . /V1 t A Tenant Name: Corj C 4sZT Property Owners Name: l..) ES r 1F1 Gl.) e_j(1,? Mailing Address: I I (oak t.0 (1_5(4( f Lcuti Name: Mailing Address: E -Mail Address: Company Name: To Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: E -Mail Address: Company Name: Mailing Address: CITY OF TUKW1L Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us 3 ts��vQ ( `' - gsr c 1P -1 trs 533 S, e ov S T 4)-y .72.1 Q ouNt iS Company Name: \AI ? fi-z-T f- FLS Mailing Address: ,o07 (f Contact Person: CA-TA 1,/ P itJe?s 7 ooa7 71 S C b /t -`t ■ it Q:1AppliationsFPorms- Applications On Line\3 -2006-Permit Application.doc Revised: 9 -2006 bh �( ■tl Contact Person: - 11- 4 " i - To([ .0 f of ) C E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Suite Number: Vm Floor: City Day Telephone: ii-I City City Day Telephone: Fax Number: New Tenant: 0 .... Yes 0 ..No Fax Number: >' c 3 - 2 - 2 C U GENERAL C ONTRACTOR I (Contractor Information for;Mechanfcal Expiration Date: U 3 L-1 tJ i 0'4 City Day Telephone: (o ( q Fax Number. (o( `f City Day Telephone: Fax Number: e � State so3 - 3 2 - 6 -- So3 o £ - 9 7L/l State Zip State qUv 2.S Zip Zip L{3 1 7 State Zip (031 7 c 3y 7 77 cot+ Y3011 State Zip b f . { (9Sy 7 ooL 61� (o11 "777 Page 1 of 6 � Avil piviv u r . r lartlY _ � x d un *4.34 Valuation of Project (contractor's bid price): $ / g o 000 Existing Building Valuation: $ Scope of Work (please provide detailed information): . FL) T€ N iA- i - /.A' ?-b J E I stir 1 5r , ft#CLL aLOs - , (ta'i Bbq )I B Will there be new rack storage? ❑.... Yes Imo'). No If yes, a separate permit and plan su ittal will be required. PLANNING DMSION: Single family building footp ' (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwellin: •rovide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ Yes yE, No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: jgg Sprinklers tiP Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes ', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: Applicationsuorms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Handicap: Page 2 of 6 : (Jnit hype , :;�ln t T�'pe Qt3'. . JAit Type ; : QtY ` oilerLCopcessor• - -,. m Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP %100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser a1,. 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator Comm/Ind MECHANICAL CONTRACTOR INFORMATION Company Name:Th, 3rD Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ i 1 1 out; Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....JE( Replacement .... ❑ Fuel Type: Electric ❑ Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q:Mpplication Worms-Applications On Line\3 -2006 - Permit Application.doc Revised: 9-2006 bh Page 4 of 6 Scope of Work (please provide detailed information): E t r s t. >'E" Water District ❑ ...Tukwila ❑... Wat District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate 0... Sewer Availabi Provided ❑ ...Total Cut ❑ ...Total Fill Please refer to Public Works Bulletin #1 for fees and estimate she ❑... Va1Vue Septic System: ❑ On -site Septic System — For on -site septic system, prov Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backfiow Prevention - Fire Protection Irrigation Domestic Wa ❑ ...Permanent Water Meter Size... ❑ ...Temporar Water Meter Size . ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension.... Public Q: 44ppliationsWorms- Applications On Linel4- 2006 - Permit Application.doc Revised: 9 -2006 bh ❑ .. Abend ❑ .. Cur ❑ .. Call before you Dig: 1 800 - 424 - 5555 Septic Tank ement Cut ooped Fire Line WO # WO # WO # Private Private ❑ .. Highline ❑ .. Renton 2 copies of a current septic design app • 'ed by King County Health Department. Geotechnical R ❑ ...Traffic Impact Analysis ..Maintenance _ ent(s) ❑...Hold Harmless —(SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Ri s f -way Use - Profit for less than 72 hours of -way Use — Potential Disturbance 0 .. Work in F od Zone ❑ .. Storm Drain 1 ) Ti c*JNT nA ?A) u rhe1- SN . ❑ ...Renton ❑ ...Seattle ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation .. Utility Undergrounding ❑ ...Deduct Water M- er Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Day Telephone: city State Zip Page 3 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGE Signature: ' Date: C O f 3 l 3 `7 Print Name: r - — 0- 4 43 � 4.- j .j�tt� ' Day Telephone: 5 3 3 Mailing Address: I ?7 S O qis\) ay Z 710 d u Cit St Zip Date Application Expires: 10L. Date Application Accepted: lo lm I tf4— QAAppliationrform,- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh Staff Initials: Page 6 of 6 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: 'To Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plumbing work (con ctor's bid price): $ ) 1 0 00 Valuation of Gas Piping work (contra Scope of Work (please provide detailed Indicate type of plumbing fixtures and/or gas piping outl Fixtur P Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Building sewer or trailer park sewer Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors ',Qty reTyl Q:\Applications\Forms- Applications On Line'.3 -2006 - Permit Application.doc Revised: 9 -2006 bh or's bid price): $ ormation): 113 ( 1 31 El_ L - Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Drinking fountain cooler (per head Food -waste commercial Ty Ingle head trap water system — per drain (inside building) Repair or alteration of water piping and/or water treating equipment Sinks Sewer: stalled and the quantity below: trite Type qty Fixtu Ty h fountain r, indirect Urinals Water Closet Water heater an vent Repair or alteration of drainage or vent piping State City Day Telephone: Fax Number: Expiration Date: 1 . i N 'FLO Gas piping outlets Additional medical gas inlets/outlets — six or more Medical gas piping system serving one to five inlets/outlets for specific gas Page 5 of 6 Receipt No.: R08 -00258 TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description doc: Receipt -06 MECHANICAL - NONRES City of Tukwila Payee: HANLIN RAINALDI CONSTRUCTION Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M07 -211 Address: 457 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/04/2007 Applicant: GILLY HICKS Issue Date: Initials: WER Payment Date: 01/30/2008 08:47 AM User ID: 1655 Balance: $0.00 Amount Payment Check 81784 933.82 Account Code Current Pmts 000/322.100 933.82 Total: $933.82 Payment Amount: $933.82 7862 01/30 9710 3c Printed: 01 -30 -2008 Initials: User ID: "1..... v rrcrnc no RECEIPT NO: R07 -02170 JEM 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http: //www.ci.tukwila.wa.us Payee: PRECISION PERMIT SERVICE SET ID: 5000000871 SET NAME: Tmp set/Ini 'Rli,ed Activities SET TRANSACTIONS: Set Member Amount D07 -381 3,707.80 EL07 -562 196.80 M07 -211 225.96 PG07 -261 37.00 TOTAL: 4,167.56 TRANSACTION LIST: Type Method Description Amount Payment Check 5007 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: 000.345.832.00.0 196.80 000/345.830 3,970.76 TOTAL: 4,167.56 Payment Date: 10/04/2007 Total Payment: 4,167.56 4,167.56 4,167.56 Account Code Current Pmts Project: Project: N: tics Type of Inspection: I1ICI, F, t-..( Address: 45 7 Mil Date Called: Special Instructions: Date Wanted: a.m. 7 - 3......2i- -7� p.m. Requester: 1306 Phone No: G 2G 76 It II■SPECTIUN'RECOlkb Retain a copy with permit INSPECTION NO. PERMIT NO. (10 ? -2/I CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: �•� Approved per applicable codes. Corrections required prior to approval. nspector: Date: V El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: , i \lAv -( l2 n -e -vvA,rv. Adrj r -f < dl o. - IF — rASstO1 Address: 1.1-47 7 S-A.,ry c-S (.A (; k 1 t - 1 r vita - 2 Oras rm. it. — fazed Special Instructions: ,.? V -, S 1.4-4--/ Date Wanted: .. /I) l O p m. V� \)- 3 R,c '�- c^-(r. Ad d ro5 , , 1 2 . . -,,( Phone No: 20 (0 — Z9 0- 012 7 6 - (5 C4 -'lc VAS -l-1 1 .1.....f ildd no, - 7 1 -1- - Pods-f S -4-4 , w. (-Ai -1 . p VA-5 R e 4"-w v j\dd ✓e tau. - - eot J (1� 4 (A I- LAC- t Project: , i Type of Inspection: Address: 1.1-47 7 me -L , 11 Date Called: Special Instructions: Date Wanted: .. /I) l O p m. Requester: Phone No: 20 (0 — Z9 0- 012 7 10 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 rY1O1-21l PERMIT NO. (206)431 -3670 .Approved per applicable codes. Corrections required prior to approval. ,inspector 1Date: l / cs ri $60.00 REINSPECTION FEE kEQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.-.. (Receipt No.: 'Date: Project• Type of Inspection: /- Address: LA n N\c:N\ Date CaaTled: Special Instructions: Date Wanted: p , • - • a a.m. P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: r.& ID Approved per applicable codes. Corrections required prior to approval. Inspector: El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Date: 'Receipt No.: 'Date: COMMENTS: ph4 Ug- 4» la.^cJ/t'c cover". /,2 4)3 c+ C C-5111"00141 04' 1 rontl A.. Loci< a...".4e/ -Pi' 14 4, Date Called: Special Instructions: _ Date Wanted: - -Z7 -Q6 IS Requester: Phone o: one o __a9° - / 7 Pro" ct: l i l t 1- 116(e< Type of Inspection: Y IF 5 e ..- zs v Addrgs 07) ^ r + '" (1 Date Called: Special Instructions: _ Date Wanted: - -Z7 -Q6 IS Requester: Phone o: one o __a9° - / 7 INSPECTION RECORD Retain a copy with permit TY107.) I PERMIT NO. CITY OF TUKWILA BUILDING. DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,1 (Z06)43j-36b INSPECTION NO. El Approved per applicable codes. El Corrections required prior to approval. 'Inspector: I7 Date: . 2 7 / El $58.0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: Project:/1 r� dS Olt 1 II, Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: 57, 3 �/ 70 a.m. P.m. Requester: Phone No: INSPECTION RECORD A1,7-ZI Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION W 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: / - Df°` 3 M y ,'()e- ?4 ?/ e4/e' OA 4)r ?di; p Inspector: ! '?s -- 'Date: 3 'z 3 O X58. EINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: c, ply 4/4 C'4 s Type of Inspection: g Nit Address: f) (CI Date Called: Special Instructions: Date Wanted: _ 5 .13 -2 a.m. p.m. Requester: j-t Fr Phone No: 1,6 2f o oI72 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - Approved per applicable codes. J Corrections required prior to approval. COMMENTS: /..2M, 5 /i/- cf,1-Pc Emig 4-111 45, f%r"4S ; /. I;" / 2 Inspector: El $58.00 paid a INSPECTION RECORD Retain a copy with permit Date: SPECTION FEE REQUIRED. Prior to inspection, fee must be 00 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: %// /l Type of /2 Inspection, Address S 7 0/ Ai !/ Date Called: Special Instructions: Date Wanted: 5 / : / Z • m. • Requester Phone No: 'J INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: P 4 6 54,e, r24-1 — Date EINSPECTION FEE REQUIRE 4. Prior to inspection, fee must be 6300 Southcenter Blvd.. Suite 00. Call the schedule reinspection. (Receipt (Date: COMMENTS: Sgr ,le/ leee/ r / 0e 'gai u 4 St <3, 6 I J /:7S74Q - //� ©Z4 til e 7 '5. Date Called: y S'a /CS ter' , Ei)a,37 j' S- Special Instructions: Date Wanted:_ 5 / a.m. p.m. Requester: Phone No: Project: // ( / � y ,4 C,d5 Type Ins ection: � — cam, /i �ver Address: Date Called: y Special Instructions: Date Wanted:_ 5 / a.m. p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION D PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - Approved per applicable codes. IA Corrections required prior to approval. Inspector: / j IDate : EINSPECTION FEE REQUIRED. Prior to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: ID $ pai 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: k N I'F Address: Wk 4 ( 1 Special Instructions: Type o nspectiof is Date Called: 4 Date Wanted: 5 _ v / - vim Requester: Phone No: Approved per applicable codes. E1 Corrections required prior to approval. COMMENTS: P I--- - ��t Q dit5 h ►sit Ins r Date: �7 (252 58 0 REINSPECTION F REQUIRED. Prior to inspection, fee must be d at 6300 Southcenter lvd.. Suite 100. Call the schedule reinspection. f Rec ipt No.: (Date: Project. 6- 1 ll y H:c s Type of Inspection: e�...A r ?e,4 Address: c , lit qtr /rr ft Date Called: 1 j - a -v Special Instructions: Date Wanted: ?- 2 2-!C s a.m. p.m. Requester: TT Ve FP Phone No: 206 ,2f0 0 12, jf 'Inspector: INSPECTION RECORD Retain a copy with permit 'Date: - 2 " I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 3 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2061431- Approved per applicable codes. 0 Corrections required prior to approval. Z COMMENTS: of ro 1 S 4' $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: . i/A7 / /C S Type of Inspection: , ad) h -ii.0 Address: 4 -/s 7 SeN the)Fivi t 144(( Date Called: Special Instructions: Date Wanted: — � p.m. 3-Zs-QL Requester: Phone No: D6- ?9O - 0r7> INSPECTION N0. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Pr 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. \Q Corrections required prior to approval. COMMENTS: /7 re Div 4rr4 S , » - 1 A A.1 T n',✓iv1c Ie ebq Date: z.� -v�, .00 REINSPECTION FE REQUIRE: Prior to inspection, fee must be Id at 6300 Southcenter B d., Suite 100. Call the schedule reinspection. 1 Rec ' ptNo.: 'Date: Project: • l / t ! • , c 5 Type of Inspection: hi,cK I A t Trr « I t ct1l j r 1. . t -1 Address: Lf S - Suite #: n ,c contact erson: Special Instructions: Occupancy Type: Phone No.: G!q/ — 3 C/ - ( Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER E Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 • 1 0 PERMIT NUMBERS G CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 ri Corrections required prior to approval. COMMENTS: j 1 (e.J1A'_ 6 {S Inspector: / y Date: - 7 i Hrs.: El $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. - T.F.D. Forth F.P. 113 Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity2 Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location Seattle, WA 98188 REVIEWED FOI' COMPLIAN APPROVED Applicant Name: WD Partners RECEIVED CITY o F Tl IKWILA CODE Applicant Address: 7007 Discovery Blvd. - Dublin, OH 43017 Applicant Phone: 614- 634 -7000 0C1 0 1 2007 PERMIT CENTER Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM Sp HP /BHP Flow Control Location of Service Efficiency` Seattle, WA 98188 REVIEWED FOI' COMPLIAN APPROVED Applicant Name: WD Partners RECEIVED CITY o F Tl IKWILA CODE Applicant Address: 7007 Discovery Blvd. - Dublin, OH 43017 Applicant Phone: 614- 634 -7000 0C1 0 1 2007 PERMIT CENTER Heating tq uipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency` Seattle, WA 98188 REVIEWED FOI' COMPLIAN APPROVED Applicant Name: WD Partners CODE Applicant Address: 7007 Discovery Blvd. - Dublin, OH 43017 Applicant Phone: 614- 634 -7000 Project Info Project Address Westfield Southcenter Date 9/26/2007 633 Southcenter Parkway For Buildingg D Use Seattle, WA 98188 REVIEWED FOI' COMPLIAN APPROVED Applicant Name: WD Partners CODE Applicant Address: 7007 Discovery Blvd. - Dublin, OH 43017 Applicant Phone: 614- 634 -7000 Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. 12 Includes Plans n Revised July 2007 UL'L i 1 LUUI City Of Tukwila B ILD1Nr Src Drawings must contain notes requireing compliance with commissioning requirements - Section 1 416 Compliance Option Q Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). ' 21 i rJ E System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Mechanical Summary (back) MECH -SUM Decision flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only LULU VV UW111191VI1 ♦7Idle IYUI II CDIUel lUcll Cnvl vwc vue INuaII%.c WI Simple System Allowed (section 1420) ( Reference Section 1421 otal Ca • . wo economize <240,000 Btuh or 10 %? Heating /Cooling or Cooling Only Yes C Reference S ection 1423 oi Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/hh Total CFM OSA CFM or Econo? SEER or EER IPLV Location Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM Sp' HP/BHP Flow Control Location of Service Efficiency' Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' Project Info Project Address Westfield Southcenter Date 9/26/2007 633 Southcenter Parkway For Building Dept. Use Seattle, WA 98188 Applicant Name: WD Partners Applicant Address: 7007 Discovery Blvd. - Dublin, OH 43017 Applicant Phone: 614 - 634 -7000 Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. Revised July 2007 Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14-1G. 3 If required. ' COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Mechanical Summary (back) MECH -SUM Decision flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( START ) Heating Only No ww II 00111111,11MI VLG ►C, nvrn waI o!GI Ely vwv vvuIIJna1 UUI II Reference Section 1421 Yes - otal Ca •. wo economize <240,000 Btuh or 10 %? Heating /Cooling or Cooling Only Reference Section 142 • Use Complex Systems (section 1430) i Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical - 2006 Washington State Nonresidential Complex Systems Checklist MECH -COMP Energy Code Compliance Forms Revised July 2007 Project Address Westfield Southcenter Date 9/26/2007 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY 1431.1 Field assem. sys. Provide calculations 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized 1434 Separate air sys. Indicate separate systems on plans 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable flow sys. Indicate variable flow on fan and pump schedules 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air 1439.2 Fume Hoods Indicate VAV, unheated/uncooled or heat rec. makeup no is circles for any question, proviae explanation: Decision flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. ( Start Here Section 1411.1 Equipmen Efficiency Shall Meet Tables 14-1A through 14-1G s/Oil Fuma input > 225,000 h or Gas/O' 1 Heat Section 1432.2.2 Hot Water Supply Temperature Reset Required 1411.1 Intermittent Ignition Device & Power Venting or Damper. If Input >_ 225,000 Btuh then 1412.6 Modulating or Staged Combustion Controls Required 1411.1 0.75% Maximum Jacket Loss Yes Section 1431.1 Calculations of Total On-Site Energy Input & Ouput Required (continued on back) Section 1432.2.1 Supply Air Reset Controls Required No 2006 Washington State Nonresidential Energy Code Compliance Fors Yes L..........W.....y ............. 11■...•. ... ............r.................. Mechanical - Complex Systems (back) MECH -COMP % Air Eco Provided? Section 1413 tor Incl. t gpmt Covr'd by Tbl 14- 1A -14- 1G? tal Cap. cono <= 480,00 Btuh or 20% of otal Cap. Section 1436 50% Effective Heat Recovery Required No Yes No DONE 4 Yes _÷, Yes-* Yes Y e Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating/Recooling Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air Yes No • Section 1433 Economizer Required Yes stem or Zon w/ Simultaneous Htg. & Cig.? Section 1437 Motors Must Meet Efficiencies in Table 14-4 Yes Section 1438 Variable Flow Devices Required Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 50fpm Face Velocity Yes Revised July 2007 Open Motors Closed Motors 3,600 I 1,800 I 1,200 3,600 I 1,800 I 1,200 Efficiency - ( %) 82.5 80.0 Efficiency 75.5 ( %) 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 924 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 930 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 930 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 _ 95.0 95.0 95.0 Electric Motors MECH -MOT 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location Minimum Nominal Full -Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP GVUU V11001111 uII VIGIL 11u1ll 00IUGI IOGI LI IVI , VWG Vulll 1101 IVG I VI III Westfield Southcenter Type (open/closed) Description of Application or Use Date 9/26/2007 For Building Department Use Synch. Speed Revised July 2007 Min.Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- IA or 14-1 B) . 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less -efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. LVW ♦VU IIII WWI I VlQlc 17V{IlcaiNCl 1412:4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. Huai cnc�yy vwc vvnINuanc.c 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14-6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper Is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Etu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo Ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and Include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb/40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water-cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14-1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper Is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Etu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo Ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and Include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb/40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water-cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Project Address Westfield Southcenter (Date 9/26/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section Component 'Information Required I Location on Plans I Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M2.1 n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans Ml .1 yes 1412.2 Deadband control Indicate 5 degree deadband minimum M1.1 yes 1412.3 Humidity control Indicate humidistat M1.1 yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types M2.1 yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage M1.1 yes 1412.4.2 Optimum Start Indicate optimum start controls M2.1 n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans M4 .1 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas Ml .1 yes 1422 Thermostat interlock Indicate thermostat interlock on plans M2.1 n.a. 1423 Economizers Equipment schedule 1413 Air economizers n . a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n. a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n. a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n. a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M4.1 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M4.1 yes 1415.1 Piping insulation Indicate R -value of insulation on piping M4.1 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 1434 Separate air sys. Indicate separate systems on plans I Mechanical Completed and attached. Equipment schedule with types, 'Su Form 'input/output, efficiency, cfm, hp, economizer I SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 - 1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank P1.1, yes 1442 Shut -off controls Indicate automatic shut -off M2.1 yes 1443 Pipe Insulation Indicate R -value of insulation on piping Ma .1 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover --_ .,- ...... .n..,... ...... .... .... no is circled for any question, provide explanation: • Sheet # Item # Description Engineering Revision addresses all Tukwila Building Division comments per memo issued 10/25/07 for Mechanical permit Application #M07 -211. Comment #1 M1.1, M1.2 Comment #2 P1.1 1.14 Added smoke detectors and duct extension on the return side of all Fan powered VAV boxes, as they all share a common plenum. 1.15 Fireplace has been revised to only be for decorative use. Removed all notes and details pertaining to gas piping. Engineering Revision addresses all Tukwila Building Division comments per memo issued 10/25/07 for Mechanical permit Application #EL07 -562. Comment #1 E4.1 1.16 Added fault current calculations for all panelboards to this sheet. Comment #2 E4.1 Comment #3 E4.1 Comment #4 E4.1 1.17 Revised the lighting fixture schedule. 1.18 29,317sca available at Switchboard SWBD. 1A per landlord drawing E7.2 -1. 1.19 The one -line drawing has been corrected with proper size protection indicated. END OF REVISION BULLETIN AF: Abercrombie & Fitch Updates BD: Building Department Comments WD: WD Partners Inc. Updates LL: Landlord Comments Page 3 of 3 October 25, 2007 Rob Humphrey Faster Permits 833 SE Main St #242 Portland OR 97214 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M07 -211 Gilly Hicks — XXX Southcenter Mall Dear Mr. Humphrey, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson, at 206 431 -3678, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience: Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, RLQ Bill Rambo Permit Technician encl xc: File No. M07 -211 City of Tukwila Department of Community Development Steve Lancaster, Director P:\Permit Center\Correction Letters \ 2007%407 -211 Correction Ltr #1.DOC wer Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 - 3670 - • Fax: 206 - 431 -3665 Building Division Review Memo Date: October 24, 2007 Project Name: Gilly Hicks Permit #: M07-211 Plan Review: Dave Larson, Senior Plan Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Duct smoke detectors are required to be on the return side of the two VAV units over 2000 cfm. The return openings may need duct extensions to enable installation of these detectors per their manufacturers listing. Per sec. 606.2.2 the other units will need duct detectors also because they share a common return plenum. See exceptions 1,2and3 sec. 6062.2 for other options to shut down the VAV's less than 2000 cfm. 2. Provide details and listing information, Including installation instructions, for the vent free gas fireplace or ventless gas log. Plans are lacking information but this fire place appears at the bottom of the responsibility schedule on sheet M2.1. Should there be questions concerning the above requirements, contact the Building Division at 206 -3670. No further comments at this time. DEPARTMENTS: VL (i 1 Building 'D ivision Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -211 DATE: 11 -28 -07 PROJECT NAME: GILLY HICKS SITE ADDRESS: 457 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued b of Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: n DATE: DATE: Planning Division ❑ Permit Coordinator No further Review Required n n DUE DATE: 11-29-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: C DUE DATE: 1 2-27-07 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 -211 DATE: 10 -04 -07 PROJECT NAME: CONCEPT 5 SITE ADDRESS: XXX SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: p� 4.weif Building 'vision Public Works Comments: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: HERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 61r C 10 , 0 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete I ✓` Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: n n ❑ Permit Coordinator ❑ DUE DATE: 10-09-07 Not Applicable n No further Review Required DATE: DUE DATE: 11-06-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Planning Division n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax etc. Date: I Plan Check/Permit Number: ❑ Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: C t l- L- 11 i! c Project Address: 45 5A1k fM C-Gv.\- Contact Person 1"M" -.0.3 DeY e-- Summary of Revision: St't s'JZ'�/tv1�.K v. CS \ Phone Number: S'() 3 ' - 11 -. ES59 Steven M Mullet, Mayor Steve Lancaster, Director RECEIVED CITY OF TUKWILA NOV 2 8 20071 L ;'ENTER Sheet Number(s): "Cloud" or highlight all areas of revision including rev' on Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1?- k kapplications\fozms- applications on line\revision submittal Created: 8-13-2004 Revised: License Information License HANLIRC962NQ Licensee Name HANLIN RAINALDI CONSTRUCTION Licensee Type CONSTRUCTION CONTRACTOR UBI 602419302 Iad. Ins. Account Id TREASURER Business Type CORPORATION Address 1 6610 SINGLETREE DR Address 2 City COLUMBUS County OUT OF STATE State OH Zip 43229 Phone 6144364204 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/18/2004 Expiration Date 7/17/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date DOUGLASS, GRANT L PRESIDENT 08/18/2004 Bond Amount HANLIN, MICHAEL 0 TREASURER 08/18/2004 RAINALDI, EDWARD M VICE PRESIDENT 08/18/2004 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Look Up a Contractor, Electric Z or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. htMv• / /fnrfress wa onv/ini/hhin /nrinter acnx9T.icenne =H ANT IRC.967NC) (11 /'0/7nfR • . NCEPT 5 ,z., „24.L.• , „7. 1 , 7.11Cit&SALE..._ „„_._ .. _ E II; _11: . `111, I m W. _ ---1-- 7 8 , : . .._1 - 0 AOKI! : . 0 SID._-_ _ ......._ SD-7 ' 150 RG MATCH LINE SHEET M1.2 C, rip. - `- _ ' - 4 •,„. a ,,,.27..‘e4. ;4 _•____„ _ = _ _ ___— -- . ,.. S-_,-..:,ITRI:KiE.S•1:1Ar A = "" v; 7 "..L : - 7 -. ,, s:.!, , A, , -5.a.Rvyay,': . - ,,__,.4, ,,, „ J 4/'' I ''''"•- :-/:`• =/- .%.T ,,51 •,- cj(TYP.) SALES #12A z. 372i/ / \ , 10'0 /,, ' 1,_3 AX----- , '=.4-. 'z r/ Igzi „ 200 . , , . Lt) z--8"0 ,, ,,,, , (2 \ ,•. , "-- , -/` \.• ,..„...-- .., ,.-,;= .4„,,,•,, ?; , 0i ' '_ LES #6 , _ - SD-q RG-4 S RG-4 1 t, G 8 150 " • 113 1 . TYP. , ,,- --/ • in , ,•-, - .ii'.. SALES #8 , di SD-2 ._ .„„ , , .. SALES #7 - rAl ti,...,,., A :. S 250 LES !,:,-, ,.,') , TOrli.e_ T V S #5 , , ,..; SAL , n , I, sp - 200 ; • P?,t7' mar i { c e 1:1 w' - ...:=7. -- ' /;,,,--- 4/ ,. K , — . ,. ./,-7, 4 •/-/ ,.'-... \/ /•\•... ---• „,- 7, = i , —---‘ / , _ ,..,.., SP —q , 517-2 SD-1 _ ;,,. . i ._ 10' 0 ------ — _r,1_) , _ r ---- 200 400 -,, u , , :-.-.... , / q _ . .... _ . .. 7, , i':.0:,)22" --7 '0 .7" i A : E/1: _: ' -,/ A - , , !.../.42`Z... - i;27 V , --!, i-„ : ' W Wil - . _ d, , Iii q R - 2 , ..,,, , , . '''a' •, V ''' . ,,.. - z 1 OF 1 , i 0 - ,-- ../ • L..... , 0 i.,,, ..,,,, _ . 1.1 / ,/:'' / A — V '' 12/12 - --.1, 0/12 . /' N , \ ,{ /, .,-) .?..% ./..%2 s/ rz„ v/ SD-8 /- • %7- SD-8 ' , •ic / .44••• ,1 Z;e* , - -- ' .;'?"-----, > ,/, 250 •,, . I 250 .1, 4 &Gz_.4 ..,,,,774-7A — 7 .?.'.'4 ' 4 , 7 7.7 : 14 ,,, 2 ./, , '4;/..- Lc.2:=2i2 ' „::::'-': ./. 11-7 7-7-.. s,', :• w,ff ,,, LA -6 AD #1 ISPLAY , Ftl. i , .2 77 ,'. C. ko CP _ 10°0---.. 1 N. ,e--10"0 ,7.. - 5 „ /7 „4.:, ..."- ,: •.-"-•- .1-11 . M3.1 c.- (TYP . 14'0 MP L_ ... Po 5 k,...1 I - 1 -I- 1L1 , , i,221. / . 26/14A RG-5 ht---= REVISION DIRECTIVE KEY I B.D.- BUILDING DEPT. T.D.- TENANT DIRECTIVE G.C. - GENERAL CONTRACTOR DIRECTIVE L.L. - LANDLORD DIRECTIVE 41 II II • j 18/14 , . ..74=__ 50 • '12)14 . II ,/.15:; _77/7 1 - 0 . ,7 1 , _;,.• ■ .„ .., .......1.4......" R_G- ..*. 1.3L-3_ , ,, ',- •, 7 - zi, - ...L ' '7 Z' tj ...,-, _ , . ,..„, \ •'/' , . i -77, P -- SALES ti 20/20 . IZG 1..1. ,-. , ;, . ,..x — -•=--- 2 z VESTIBULE <•-'-z\ A: MD ,- , \ PORCH i - ■-• ••-■■.•.; .... 4 =e \ \.=. 10 2400 CRI 3 6749 0 2100 CFT1 cj .r. .1 - , SALES #10 ,, ) RG-5 , 2/ SD-1 0 . , ,,... - L. -.L-_-:: 250 i 4‘ - r/I r:' '`.., / -, REVISIONS: BLDNG DEPT 11 -21 -07 I . -5 RG-5 A , :;..,. . ' , / ,. ..- 20/20 :..1->-7 7 -;-- :._•, .4.. MIIIIII MMINIIMI :. •:;./%/./.,, ,, ,./7 Tilf ----- - - / — / ._ & - \ 14'P ,i s 4/14 ti, I rill , 1 ' I '.,•-0' • 4 22/14 III ., -5 10/14 O. ,,„ ----- ,,-, -•4 50 , 'A - 4-:: 0 i ....- , I LAY #2 MP II ,, ,• A ,-„. 10 /4_ '/A CI Z.L , v, ,4 4z , TO VAV-2 .., - 10"0 0 r13.1 rrp.) „AI , E,b 1 ..<,/ . ,, ,,, . ___....„, _.,..,..,... . , • - , , /1 , ..-10/12 SD-8 ,. .,-.,., 10/12-- ...._ Lir fl I --- „. 4,,,,, ,-74,y.'4,,,-.-,4-..,:,,„,, 12"0 i _. „ .. „,, .. 250 , RG-4 ->,:- .,. C _ .. . . 1 o — Nd - > . i 5D-2 ' FILE COPY I ISSUE DATE: PERMIT DATE: 9/15/071 I LANDLORD DATE: 9/74/071 I BID DATE: 9H6/071 MASTERS 7 -27 -2007 . 0 , " ,,. . 5Z, /' SEPARATE PERMIT REQUIRED FOR: 0Mechanical V, Electrical Permit Ne. 1101•1 0 ,1 , 10 0 -N.,--> ,.,. . .„.. ,..... , i Plan MIAOW appronibisubjectlosismandomissions. Approval of conetroollondocemergedaeanotaufrodze the violation of my adcialed code cream= Receipt of approved Flekl !----( andcadillonelsackodedged: M3.1 rrp .... - 1 'L.., „,•-• - 13 ) ..) SD-2 J 225 A, .. . • 250 7272= , 10,0--•-• „ ,y, - 10'0 . • SALES #9 ; .„• m : i'.;; : SALES ., -, -4- ?„ • Ilk sl SD-1 .,..,,,..„, .,1 ' '-'(*. , SALES #8 #2 . 0 350 9.,. .... ,. , - . .g2L1\_17itYjPG:atiGtSiTibiTP;.:(WligVngliSlalON ,_. BUACRY11.134214;diggieSDIVISICX4 p. . . i • .' . , : , -10"0 :•--: , • i I . , : 1 --I 1 ,./‘. vi , t ", 7 77 • / E 7 ,,,___.„ ,-• , „ SALES #1 LAN CONCEPT 5 115 WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY SEATTLE, WA 98188 gI- : )I HO TYP.) 0 -N,--> - , -2 ' -4:0- '',. 5D-2 SD-2 ., -,, ' REVISIONS 250 (-\r-- 225 ' No changes shall be ma7f e to the SCopP Of Work without prior approval of Tukwila Building Division. : ll require a new plan subMittal NOTE Revisions wi ag=1 . ,-----7,„ 7 --- ' 200 t- , i / , 2y, K - RG-4 - - ,r, -,--i, . 0 -- ,i4. 'V Z -- xiii ' RG-4 ., RG-4 ,..- C) TIT.) and may include additional plan review fees. 1 r''„ ' " ."... , DRAWN: TJ ._ „ . - - — , ._ _ .,_ t::-.`: -.;,'-',.- f .e , 2', 2 , , zi --7 e ,,,--., ,'-,- . , , _ L LA ,i- - - ' ,t 'ZR,P a., . --a , :. _ ....1.,-, _ ..0. ' ' ' 7,R ' . - . - - MECHANICAL PLAN 1/4" = 1'-0" aaM = YVa u GENERAL NOTES: KEYED NOTES: (NOTES APPLY TO SHEETS M1.1 AND M1.2) ,,----\ > LANDLORD NOTES: A. THE CONTRACTOR FOR TI-IIS DIVISION OF WORK IS REQUIRED TO READ TI-IE SPECIFICATIONS AND REVIEW DRAWNGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THE CONTRACTOR'S REsPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. B. ALL ROOF CUTTING, PATCI-IING AND FLASHING REQUIRED TO INSTALL THE MECHANICAL SYSTEMS S1-ALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S l<PENSE. COORDINATE ALL ROOF PENETRATIONS WITH LANDLORD AND GENERAL CONTRACTOR. C. THE MEGI-IANICAL CONTRACTOR SI-1ALL ENSUE I-I RE AT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT BEING USED OR SHOWN TO REMAIN, 15 FULLY REMOVED AND NOT ABANDONED. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION. D. CONTRACTOR 51-1ALL FURNISH AND INSTALL ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT ANY MECHANICAL EQUIPMENT. TI-115 CONTRACTOR SHALL COORDINATE LOCATIONS AND REQUIREMENTS WITH THE GENERAL CONTRACTOR AND LANDLORD PRIOR TO BID. E. COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTION AND TESTING OF ALL UTILITIES OR INTERFACED SYSTEMS WITH TI-IE LANIDLORD'S FIELD REPRESENTATIVE. F. PROVIDE ACCESS FOR ALL LANDLORD AND TENANT COMPONENTS REQUIRING PERIODIC INSPEcTIoN AND SERVICE TI-IAT ARE LOCATED WITI-IIN TI-IE SPACE OR REQUIRE ACCESS °. C, 0 ALL ROOM THERMOSTAT'S/TEMPERATURE SENSOR'S, FURNISHED 5Y OWNER AND INSTALLED ACCESS PANEL TO ACCESS EQUIPMENT LOCATED ABOVE CEILING. CONTRACTOR SHALL BE , ..-, - • - `,44 . .:• d t\ BY MEC14ANICAL CONTRACTOR AT 48" ABOVE TI-IE FINISHED FLOOR. NOTE: THERE MAY BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3-FEET ....If-0 „ •,,,o • V mULTIPLE SENSORS FOR EACH sYsTEM. cl-IECK DRAWINGS CAREFULLY TO VERIFY VERTICALLY AND 2-FEET 140RIZONTALLY N ALL DIRECTIONS AROUND EQUIPMENT IS `''''' L 'c'iS- 40SS QUANTITIES. MAINTAINED To ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. IF THIS FREE AREA CAN NOT BE OBTAINED, CONTACT THE OWNER'S CONSTRUCTION MANAGER \CP' Oe' v- ,lv,',1% .,,,.., 0 PRE-ASSEMBLED TEMPERATURE/LIGHTING CONTROL PANEL FURNLISHED BY OWNER AND ....--' INSTALLED BY THE MECHANICAL CONTRACTOR. ALL CONDUITS BY THE ELECTRICAL IMMEDIATELY. \ CONTRACTOR. REFER TO SEQUENCE OF OPERATIONS 51-IEET M2.1 FOR FURTHER INFORMATION. alSTNG DUCTWORK TO REMAIN. TYPE, SIZE AND ELEVATION ARE AS NOTED. \ \,: ‘M'i" " \-. . „ 0 RELIEF AIR THROUGI-I STOREFRONT CUSTOMER ENTRANCE TO MALL CONCOURSE. e DEllisING WALLS SHALL STOP 6" BELOW ROOF DECK TO ALLOW FOR MALL'S COMMON RETURN AIR. REFER TO ARCI-IITECTURAL SHEETS FOR MORE INFORMATION. PLENUM AIR SENSOR FURNISHED BY OWNER AND INSTALLED BY THE MECHANICAL @ \'.....‘. CONTRACTOR. INSTALL SENSOR ABOVE CEILING AND MOUNT SECURELY TO TI-IE STRUCTURAL 0 AIR DEVICE TO BE USED FOR ACCESS TO EQUIPMENT LOCATED ABOVE CEILING. 13AR JOIST. VERIFY EXACT LOCATION OF SENSOR WITH OWNER'S CONSTRUCTION MANAGER CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE TI-IAT A MINIMUM UNOBSTRUCTED FREE PRIOR TO INSTALLATION. AREA OF 3-FEET VERTICALLY AND 2-FEET 140RIZONTALLY IN ALL DIRECTIONS AROUND ® MSTING PIPING TO REMAIN. TYPE, SIZE AND ELEVATION ARE AS NOTED. EQUIPMENT 15 MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. IF THIS FREE AREA CAN NOT BE OBTAINED, CONTACT THE 14OLLISTER CONSTRUCTION ® MECI4ANICAL CONTRACTOR S1-IALL FIELD FABRICATE SUPPLY AIR PLENUM BOX. REFER TO MANAGER IMMEDIATELY. ARCHITECTURAL DETAIL Aq.3A FOR MORE INFORMATION. ®RELATIVE 14UMIDITY SENSOR PROVIDED WITH I-1VAC CONTROLS. RI4 SENSOR TO BE ® OWNER SHALL FURNISH AND MECHANICAL CONTRACTOR SHALL INSTALL FAN POWERED VAV INSTALLED BY THE MECI-IANICAL CONTRACTOR AT 48" ABOVE FINISI4ED FLOOR. BOX AS SHOWN. VERIFY BOX INLET AND OUTLET CONNECTION SIZES AND INCLUDE DUCT 0 SMOKE DETECTOR FURNISHED AND WIRED BY ELECTRICAL CONTRACTOR, INSTALLED BY i MECHANICAL CONTRACTOR. SMOKE DETECTOR MUST BE IN AN ACCESSIBLE LOCATION IN AIR ® EF-1 - ACME V 1080 TOILET EXHAUST FAN COMPLETE WITH INTEGRAL BACKDRAFT DAMPER DUCT. MECHANICAL CONTRACTOR TO WIRE THE SHUT DOWN SEQUENCE OF THE I-1VAC FAN I. DO NOT ATTACH ANYTI-IING DIRECTLY TO SLAB OR ROOF DECK. > 2. TENANT SHALL MAINTAIN A MINIMUM OF 6" UNOBSIRUCTED CLEARANCE HEIGHT IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIRFLOW BACK TO LANDLORD AIR CONDITIONING UNIT. DSG N R: CAB CORRECTION LT R# _.\--- -- DT RECEIVED CITY OF TUKWILA I SCALE:AS NOTED I ...a_...„A ,..,_ . _.., , t „van str ... .. .1', ---- tpec, ..kv....- • - • - ---;-4.-,.. _ i'...., ‘, , ti ,.. ir_\ - %\ ./ t rl '.,: , - ..O c, .: ...,, - v5 TI-IROUGH TI-IE SPACE. LABEL ACCESS DOORS AND PANELS OR CEILING TILES, RETURN REGISTERS OR DIFFUSERS UTILIZED FOR ACCESS WITH THE NAME OF THE 1-11DDEN COMPONENT(S). DEMONSTRATE ACCESS TO ALL I-IIDDEN COMPONENTS FOR TI-1E LANDLORD'S SHALL BE FURNISHED BY OWNER WITH LIGHTING PACKAGE AND INSTALLED BY MECHANICAL UPON SENSING SMOKE. CONTRACTOR. VHAUST CAPACITY SHALL BE 80 CFM AT 0.25 S.P., 120V, 10, .48 WATTS. CONTRACTOR TO FURNISH AND INSTALL EXHAUST DUCT AND ALL REQUIRED ACCESSORIES. FIELD REPRESENTATIVE PRIOR TO oCCUPANCY. G. THE MECI4ANICAL CONTRACTOR SHALL FURNISH AND INSTALL IDENTIFICATION ON ALL 1-IVAC EQUIPMENT. PROVIDE PLASTIC LAMINATED PLATE OR STENCIL WITH 2" 1 BLACK LETTERS, INDICATION VI IT1-1 LANDLOR TENANTS NAME AND SPACE NUMBER. VERIFY ACTUAL REQUIREMENTS D. MECHANICAL CONTRACTOR SI-IALL FILL OUT COMPLETELY AND SUBMIT TO TI-1E CONSTRUCTION MANAGER THE STARTUP CI-IECKLIST FOR EACH RESPECTIVE PIECE OF EQUIPMENT INSTALLED PRIOR TO SCHEDULNG THE I4VAC CONTROL STARTUP. I. MECHANICAL CONTRACTOR MUST 14AVE A SENIOR FOREMAN WITH A MINIMUM OF FIVE YEARS COMMISSIONING EXPERIENCE IN BOTI-1 I-1VAC AND CONTROLS PRESENT AT STARTUP. J. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING PEIGHT5 AND GENERAL COORDINATION. CONNECT DUCT TO EXISTING MALL CENTRAL EXHAUST SYSTEM. FIELD VERIFY EXACT LOCATION AND COORDINATE CONNECTION WITH LANDLORD. INSTALL TOILET EXHAUST FAN IN LOWER DRYWALL CEILING. VO E • PER ITI-I UNG GU OR -2 ON C • - CO ROL sYSTEM TO ALLOW FOR BALANCNG OF TI-IE I-1VAC SYSTEM. DAMPER CONTROL SI-IALL BE LOCATED WITHIN TI-1E SUPPLY DIFFUSER PLENUM 30X. REFER TO DETAIL ON 51-1EET M3.I FOR MORE INFORMATION. g GENERAL CONTRACTOR SHALL UNDERCUT DOOR 1" FOR AIRFLoW. (1) MECHANICAL CONTRACTOR TO FURNISH AND INSTALL MEDIUM PRESSURE DUCT, FROM LANDLORD EXISTING SUPPLY MAIN TO VAV BOX SIZE AS INDICATED. CONTRACTOR TO FURNISH AND INSTALL SADDLE TAP AT CONNECTION IF EXISTING NOT AVAILABLE. FIELD VERIFY EXACT LOCATIONS AND REQUIREMENTS. -i, . . , FIELD VERFY ALL COPENTION8 Pt-4-inni i ( :III.7_1n DESIGN DRAWINGS ARE SCHEMATIC. 11-115 CONTRACTOR SWALJ- VISIT THE SITE PRIOR TO BIDDING OR AWARD Of CONTRACT TO INSPECT MISTING FIELD CONDMCNS. ThIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITICRS. TI•IE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR-OWNER FRICR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN NIS 8ID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE ET TNE AR.CNITECT, ENGINEER OR OMER AFTER BIDDING WILL. ESE FINAL AND SMALL ESE IMPLEMENTED AT CONTR.ACTORS COST. 'BIDDING CONTRACTORS WALL WAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SWALL INCLUDE IN 114EIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT 141M45TANDING. THE CONTRACTOR SMALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN At GOVERNING CODES AND DESIGN INTENT. ABFC50017 SHEET M • 1 1 L I r 5D -4 75 SS - 75 10/10 I 1 , sr I11 -- I f r I I I I , w L 24/18 MP 14/12 SD-3 200 I I SD -3 200 l SALES *12A I � g 1- - -- -12/12 SALES 412B .,'NON= SALES " °' .. 26/141' v., SD -8 250 SD -4 �I J7, it ' 7.7/(!%70 CORRIDOR I A, MATCH LINE SHEET Mil L FR 10'0 1 1 5Dr2 250 10 °0 10/12 104 10 4 250 SALES *9 €2\ SD -2 � T250 E MECHANICAL PLAN NS 1/4" w GENERAL NOTES: A. THE CONTRACTOR FOR THIS DIVISION OF WORK 15 REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT 15 THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. B. ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE MECHANICAL SYSTEMS SHALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. COORDINATE ALL ROOF PENETRATIONS WITH LANDLORD AND GENERAL CONTRACTOR. C. THE MECHANICAL CONTRACTOR SHALL ENSURE TI-IAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT BEING USED OR SHOWN TO REMAIN, IS FULLY REMOVED AND NOT ABANDONED. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION. D. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT ANY MECHANICAL EQUIPMENT. THIS CONTRACTOR SI-IALL COORDINATE LOCATIONS AND REQUIREMENTS WITH THE GENERAL CONTRACTOR AND LANDLORD PRIOR TO BID. E. COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTION AND TESTING OF ALL UTILITIES OR INTERFACED SYSTEMS WITH THE LANDLORD'S FIELD REPRESENTATIVE. F. PROVIDE ACCESS FOR ALL LANDLORD AND TENANT COMPONENTS REQUIRING PERIODIC INSPECTION AND SERVICE THAT ARE LOCATED WITHIN THE SPACE OR REQUIRE ACCESS THROUGH THE SPACE. LABEL ACCESS DOORS AND PANELS OR CEILING TILES, RETURN REGISTERS OR DIFFUSERS UTILIZED FOR ACCESS WITH THE NAME OF THE HIDDEN COMPONENT(S). DEMONSTRATE ACCESS TO ALL HIDDEN COMPONENTS FOR THE LANDLORD'S FIELD REPRESENTATIVE PRIOR TO OCCUPANCY. G. THE MECI-IANICAL CONTRACTOR SHALL FURNISH AND INSTALL IDENTIFICATION ON ALL HVAC EQUIPMENT. PROVIDE PLASTIC LAMINATED PLATE OR STENCIL WITH 2' HIGH BLACK LETTERS, INDICATION TENANTS NAME AND SPACE NUMBER. VERIFY ACTUAL REQUIREMENTS WITH LANDLORD. H. MECHANICAL CONTRACTOR SHALL FILL OUT COMPLETELY AND SUBMIT TO THE CONSTRUCTION MANAGER THE STARTUP CHECKLIST FOR EACH RESPECTIVE PIECE OF EQUIPMENT INSTALLED PRIOR TO SCHEDULING TI-IE HVAC CONTROL STARTUP. I. MECI-IANICAL CONTRACTOR MUST HAVE A SENIOR FOREMAN WITH A MINIMUM OF FIVE YEARS COMMISSIONING EXPERIENCE IN BOTH HVAC AND CONTROLS PRESENT AT STARTUP. J. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND GENERAL COORDINATION. KEYED NOTES: (NOTES APPLY TO SWEETS M1.1 AND M1.2) ® ALL ROOM TI- IERMOSTAT'S/TEMPERATURE SENSOR'S, FURNISHED BY OWNER AND INSTALLED BY MECHANICAL CONTRACTOR AT 48" ABOVE THE FINISHED FLOOR. NOTE: THERE MAY BE MULTIPLE SENSORS FOR EACH SYSTEM. CHECK DRAWINGS CAREFULLY TO VERIFY QUANTITIES. ® PRE - ASSEMBLED TEMPERATURE/LIGHTING CONTROL PANEL FURNISHED BY OWNER AND INSTALLED BY THE MECHANICAL CONTRACTOR. ALL CONDUITS BY THE ELECTRICAL CONTRACTOR. REFER TO SEQUENCE OF OPERATIONS SHEET M2.1 FOR FURTHER INFORMATION. ® RELIEF AIR THROUGH STOREFRONT CUSTOMER ENTRANCE TO MALL CONCOURSE. ® PLENUM AIR SENSOR FURNISHED BY OWNER AND INSTALLED BY THE MECHANICAL CONTRACTOR. INSTALL SENSOR ABOVE CEILING AND MOUNT SECURELY TO THE STRUCTURAL BAR JOIST. VERIFY EXACT LOCATION OF SENSOR WITH OWNER'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. ® EXISTING PIPING TO REMAIN. TYPE, SIZE AND ELEVATION ARE AS NOTED. ® MECHANICAL CONTRACTOR SHALL FIELD FABRICATE SUPPLY AIR PLENUM BOX. REFER TO ARCHITECTURAL DETAIL Aq.3A FOR MORE INFORMATION. ® OWNER SI -IALL FURNISH AND MECHANICAL CONTRACTOR SHALL INSTALL FAN POWERED VAV BOX AS SHOWN. VERIFY BOX INLET AND OUTLET CONNECTION SIZES AND INCLUDE DUCT N N • T TI ® gF -I - ACME VQ80 TOILET EXHAUST FAN COMPLETE WITH INTEGRAL BACKDRAFT DAMPER SHALL BE FURNISHED BY OWNER WITH LIGHTING PACKAGE AND INSTALLED BY MECHANICAL CONTRACTOR. EXHAUST CAPACITY SHALL BE 80 CFM AT 0.25" S.P., 120V, 10, 48 WATTS. CONTRACTOR TO FURNISH AND INSTALL EXHAUST DUCT AND ALL REQUIRED ACCESSORIES. CONNECT DUCT TO EXISTING MALL CENTRAL EXHAUST SYSTEM. FIELD VERIFY EXACT LOCATION AND COORDINATE CONNECTION WITH LANDLORD. INSTALL TOILET EXHAUST FAN IN LOWER DRYWALL CEILING. ® q PROVIDE VOLUME DAMPER WITH YOUNG REGULATOR 270 -275 BOWDEN CABLE CONTROL SYSTEM TO ALLOW FOR BALANCING OF THE HVAC SYSTEM. DAMPER CONTROL SHALL BE LOCATED WITHIN THE SUPPLY DIFFUSER PLENUM BOX. REFER TO DETAIL ON SHEET M3.1 FOR MORE INFORMATION. ® GENERAL CONTRACTOR SHALL UNDERCUT DOOR 1" FOR AIRFLOW. II MECHANICAL CONTRACTOR TO FURNISH AND INSTALL MEDIUM PRESSURE DUCT, FROM LANDLORD EXISTING SUPPLY MAIN TO VAV BOX SIZE AS INDICATED. CONTRACTOR TO FURNISH AND INSTALL SADDLE TAP AT CONNECTION IF EXISTING NOT AVAILABLE. FIELD VERIFY EXACT LOCATIONS AND REQUIREMENTS. ® ACCESS PANEL TO ACCESS EQUIPMENT LOCATED ABOVE CEILING. CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3 -FEET VERTICALLY AND 2 -FEET HORIZONTALLY IN ALL DIRECTIONS AROUND EQUIPMENT IS MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. IF THIS FREE AREA CAN NOT BE OBTAINED, CONTACT THE OWNER'S CONSTRUCTION MANAGER IMMEDIATELY. .0 EXISTING DUCTWORK TO REMAIN. TYPE, SIZE AND ELEVATION ARE AS NOTED. ® DEMISING WALLS SHALL STOP 6" BELOW ROOF DECK TO ALLOW FOR MALL'S COMMON RETURN AIR. REFER TO ARCHITECTURAL SHEETS FOR MORE INFORMATION. ® AIR DEVICE TO BE USED FOR ACCESS TO EQUIPMENT LOCATED ABOVE CEILING. CONTRACTOR SI-IALL BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3 -FEET VERTICALLY AND 2 -FEET HORIZONTALLY IN ALL DIRECTIONS AROUND EQUIPMENT 15 MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. IF THIS FREE AREA GAN NOT BE OBTAINED, CONTACT THE 1-1OLLISTER CONSTRUCTION MANAGER IMMEDIATELY. ® RELATIVE HUMIDITY SENSOR PROVIDED WITH HVAC CONTROLS. R14 SENSOR TO BE INSTALLED BY THE MECHANICAL CONTRACTOR AT 48 ABOVE FINISHED FLOOR. O. SMOKE DETECTOR FURNISHED AND WIRED BY ELECTRICAL CONTRACTOR, INSTALLED BY MECHANICAL CONTRACTOR. SMOKE DETECTOR MUST BE IN AN ACCESSIBLE LOCATION IN AIR DUCT. MECHANICAL CONTRACTOR TO WIRE THE SHUT DOWN SEQUENCE OF THE HVAC FAN UPON SENSING SMOKE. CODE COMPLIANCE 1 a °., c I Of TuV 4I' L DI P r,ITSION ; .a RECEIVED CITY OF TUKWILA n P �ai�ij! o N!ER MECHANICAL CONTRACTOR MUST HAVE A SENIOR FOREMAN WITH A MINIMUM OF FIVE YEARS COMMISSIONING EXPERIENCE IN BOTH VAC AND CONTROLS PRESENT AT STARTUP. FIELD VERFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. TNI5 CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT IVIST1NG FIELD CONDITIONS. THIS CONTRACT SHALL Wq,.UDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN MS BID ALL. COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR 81DS THE COSTS FOR ALL. WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CANTRACTOR SHALL ALERT ARCHITECT, ENGINE R OR MINER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 0 1- §Iu aL t Lula u w I -- H ci c W SL i za wa cc — w ?_:0 co o� ca W la _ w aW W LL g V I CI) I. aW�,a v� U m ci ABFC50017 SHEET M1.2 DESIGN WEATHER DATA VAV BOX SCHEDULE MECHANICAL /PLUMBING RESPONSIBILITY SCHEDULE rCEPT 5 Design Parameters: NOTE: ANY ITEM NOT SPECIFICALLY INDICATED TO BE FURNISHED BY THE OWNER OR THE LANDLORD SHALL BE FURNISHED BY THE RESPECTIVE CONTRACTOR. ANY ITEM NOT SPECIFICALLY INDICATED TO BE INSTALLED B LANDLORD OR ANOTHER CONTRACTOR SHALL BE INSTALLED BY THE RESPECTIVE CONTRACTOR. City Name Seattle TAP Location Washington Latitude 47.5 Deg. Longitude 122.3 Deg- Elevation 449.0 ft Summer Design Dry-Bulb 85.0 °F Summer Coincident Wet -Bulb 65.0 °F Summer Daily Range 18.3 °F Winter Design Dry-Bulb 23.0 °F Winter Design Wet -Bulb 19.2 °F Atmospheric Clearness Number 1.05 Average Ground Reflectance 0.20 Soil Conductivity 0.800 BTU /(hr -ft °F) Local Time Zone (GMT +1- N hours) 8.0 hours Consider Daylight Savings Time No Simulation Weather Data noneN/A Current Data is 2001 ASHRAE Handbook Design Cooling Months January to December MARK MANUFACTURER BOX TYPE/ MODEL # BOX SIZE INLET DUCT SIZE OUTLET DUCT SIZE CFM RANGE FAN WP VOLT / PHASE NOTES MIN. MAX VAV -1 TRANE VSCF14 14 14 ' 2.4 1200 2400 0.5 277 1� 0 ITEM a z p[ J 3 O U) 0 J p/ J z 3 N O V a lt3 U) o J V ' Z f] W O O t7 Q j U) O O O 1 4 _ Q 0 Z x W REM, VAV -2 TRANE VSCF14 14 l4 144) 24 1050 2100 0.5 277 1Qt �1 VAV -3 TRANE VSCF12 12 12 "� 224N18" 8" q00 1800 0.5 277 1� � �' / V AIR HANDLING UNIT o AHU FINAL COMMISSION • VAV -4 TRANE VSCF08 8 8 "8'4 19 "x16 400 800 0.333 277 1� O AIR BALANCE REPORT • VAV -5 TRANE VSCF08 8 8 "� 11 16 450 q00 0.333 277 1� 0 AIR SYSTEM SIZING SUMMARY AS -BUILT DRAWINGS 0 MOTOR OPERATED DAMPERS $ ACTUATORS • Air System Information Air System Name Southcenter Number of zones 1 Equipment Class PKG ROOF Floor Area 8618.0 ft Air System Type VAV Location Seattle TAP, Washington Sizing Calculation Information Zone and Space Sizing Method: Zone GEM Peak zone sensible load Calculation Months Jan to Dec Space CFM Individual peak space loads Sizing Data User - Modified Central Cooling Coil Sizing Data Total coil load 13.5 Tons Load occurs at Jul 1200 Total coil load 161.7 MBH OA D8 / WB 80.8 / 63.6 °F Sensible coil load 136.5 MBH Entering DB / WB 80.3 / 65.0 °F Coil CFM at Jul 1200 5287 CFM Leaving DB ! WB 56.0 / 54.6 °F Max block CFM 6137 CFM Coil ADP 53.3 °F Sum of peak zone CFM 8000 CFM Bypass Factor 0.100 Sensible heat ratio 0.844 Resulting RH 50 % BTU/( ) 639.5 Design supply temp. 56.0 BTU /(hr ft 18.8 Max zone stet Check 1 of i OK Water flow @ 10.0 rise N/A Max zone temperature deviation 0.0 °F Preheat Coil Sizing Data No heating coil loads occurred during this calculation. Supply Fan Sizing Data Actual Max CFM 6137 CFM Fan motor BHP 0.00 BHP Standard CFM 6038 CFM Fan motor kW 0.00 kW Actual max CFM/ft 0.71 CFM/ft Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow GFM 0 CFM CFM/person 0.00 GFM/person CFM/ft CFM/ft CONDENSING UNITS • NOTES: 0 REFER TO FLOOR PLAN FOR ACTUAL VAV BOX CFM ROOF CURBS AND /OR CURB ADAPTOR FOR CONDENSING UNITS AS REQUIRED STRUCTURAL SUPPORTS FOR I4VAC UNITS AS REQUIRED • • V.A.V. BOXES • DIFFUSERS AND GRILLES • FIRE EXTINGUISHERS 0 0 CEILING FIRE DAMPERS AND /OR COMBINATION SMOKE/FIRE DAMPERS • TEMPERATURE /LIGHTING CONTROL SYSTEM & COMMISSIONING SEQUENCES OF OPERATION LOW PRESSURE DUCTWORK • 0 CONTROL SYSTEM SEQUENCES OF OPERATION HIGH /MEDIUM PRESSURE DUCTWORK • • TEMPERATURE CONTROL PANEL (TCP) OPERATION: THE MECHANICAL CONTRACTOR SHALL INSTALL A COMPLETE CONTROL SYSTEM TO AUTOMATICALLY CONTROL THE HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT AS SPECIFIED HEREIN AND AS SHOWN ON THE BID SET DRAWINGS. OWNER SHALL PROVIDE TO THE MECHANICAL CONTRACTOR ALL CONTROL EQUIPMENT NECESSARY TO PERFORM THE SEQUENCES OF OPERATION, EXCEPT AS SPECIFICALLY NOTED OTHERWISE. SYSTEM TO BE UL LISTED AS A WHOLE. THE I-1VAC CONTRACTOR IS RESPONSIBLE TO CONTACT OWNER THREE WEEKS PRIOR TO CONSTRUCTION COMPLETION DATE TO SCHEDULE COMMISSIONING. THIS CONTRACTOR MUST HAVE CONTROL NUMBER AND HAVE SIGNED OFF ON THE CONTROL PANEL AT J08 SITE. FAILURE TO MENTION ANY SPECIFIC ITEM OR DEVICE DOES NOT RELIEVE THE MECHANICAL CONTRACTOR OF THE RESPONSIBILITY FOR INSTALLING OR PROVIDING SUCH DEVICES OR ITEMS IN ORDER TO ACHIEVE THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. DRAWINGS ALL 24 VOLT PLENUM RATED WIRE ASSOCIATED WITH CONTROLS SHALL BE PROVIDED BY OWNER AND INSTALLED BY THE MECHANICAL CONTRACTOR. LINE VOLTAGE WIRING, EQUIPMENT STARTERS AND DISCONNECTS AND ALL CONDUITS SHALL BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR IS TO PROVIDE WEATHERPROOF DISCONNECTS FOR ROOFTOP UNITS. VAV 80XE5 WITH HEAT WILL 8E PROVIDED WITH ALL R1= QUIRED CONTROLS, CONTACTORS AND DISCONNECT SWITCHES, E.C. WILL HAVE A SINGLE POINT CONNECTION. ALL WIRING AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODES. THE MECHANICAL CONTRACTOR SHALL RENDER WHATEVER ASSISTANCE IS REQUIRED BY THE ELECTRICAL CONTRACTOR IN MAKING POWER GONNEGTIONS TO THE CONTROL DEVICES. OWNER SHALL PROVIDE COMPLETE WIRING AND INSTALLATION INSTRUCTIONS FOR ALL TEMPERATURE CONTROL EQUIPMENT WITH THE TEMPERATURE CONTROL PACKAGE. ALL CONTROL WIRING DIAGRAMS WILL BE SPECIFIC TO EQUIPMENT CONTROLLED AND MUST REMAIN WITH RECORD DRAWINGS AT COMPLETION OF PROJECT. COMMISSIONING HIGH /MEDIUM PRESSURE TAPS 0 0 THE TCP HAS ABUILT - IN TIME CLOCK WHICH SHALL BE SET FOR OCCUPIED AND UNOCCUPIED HOURS. THE TCP SHALL CONTROL EVERY PIECE OF PRIMARY 1-IVAC EQUIPMENT. UPON A LOSS OF SIGNAL FROM THE TCP, THE CONTROL BOARD IN EACH PIECE OF PRIMARY EQUIPMENT SHALL MAINTAIN A SET POINT OF 74°F IN THE COOLING MODE AND 71 °F IN THE HEATING MODE. THE TCP SHALL CONTROL THE LIGHTING AS WELL AS THE PRIMARY HYAG UNIT(S), AND SHALL BE EQUIPPED WITH ONE HOUR OVERRIDE CONTROLS TO TURN THE LIGHTS ON DURING UNOCCUPIED HOURS. THE TCP SHALL ALSO HAVE A TELEPHONE CONNECTION FOR REMOTE MONITORING AND CONTROLLING. MOTOR OPERATION: DUCT /UNIT/BASE80ARD HEATERS • RETURN AND /OR RELIEF FAN • TOILET EXHAUST FAN(S) • • DURING OCCUPIED HOURS THE TCP SHALL ENERGIZE THE FAN(S) AND SHALL CAUSE THE FAN(S) TO CONTINUALLY OPERATE. SENSOR OPERATION, TOILET EXHAUST DUCTWORK AND /OR ROOF CAP • • PLUMBING FIXTURES • • AS SPECIFI ED NO SUBSTITUTIONS EACH UNIT MAY HAVE MULTIPLE SENSORS. MULTIPLE SENSORS SHALL AVERAGE THE SPACE TEMPERATURE AND SHALL HAVE A DEAD BAND SETTING OF 0.5. THE SENSORS ARE NOT CONTROL DEVICES. THE TCP WILL CONTROL THE UNIT 5 ()' COOLING MODE: B.D.- BUILDING DEPT. T.D.- TENANT DIRECTIVE G.C.- GENERAL CONTRACTOR DIRECTIVE L.L.- LANDLORD DIRECTIVE ELECTRIC WATER COOLER AND ELECTRIC Vt ACCE550RIE5 SAN. GW /+�W. GA5 PIPING/REGULATORS AND METERS AS REQUIRED • • • • AS SPECIFI NO SUBSTI - NO EQUALS, ZONE SIZING SUMMARY DURING OCCUPIED HOURS THE SALES AREA SHALL BE MAINTAINED AT 72 "F AND THE NON -SALES AREA SHALL B!" MAINTAINED AT 75 °F. DURING UNOCCUPIED HOURS ALL AREAS SHALL BE MAINTAINED AT 85 °F. HEATING MODE: Air System Information Air System Name Southcenter Number of zones 1 Equipment Class PKG ROOF Floor Area 8618.0 ft Air System Type VAV Location SeattleIAP,Washington Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Peak zone sensible load Calculation Months Jan to Dec Space CFM Individual peak space loads Sizing Data User- Modified Zone Sizing Data SPRINKLER PIPING AND HEADS le • DUING OCCUPIED HOURS THE SAL£5 AREA SHALL BE MAINT R AINED AT 68 °F AND THE NON -SALES AREA SHALL BE MAINTAINED DU ING DURING UNOCCUPIED HOURS, ALL AREAS SHALL T MAINTAINED AT 55 °F. WATER HEATER • VIBRATION ISOLATORS • DURING OCCUPIED HOURS THE •I ' - - - - OPE ►•. • - -•- - IRED OUTSIDE AIR (SEE LOAD SUMMARY ON THIS SHEET F0: • - - - c ■ - D HO - , - - - - ■ • - SHALL REMAIN FULLY SMOKE EVACUATION SYSTEM WORK • LLB Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CPM) Time of Peak Load Maximum Heating Load (MBH) zone Floor Area (n = > Zone CFM/ft2 FIREPLACE GAS LINES METER SHUT -OFF / / • • fry r ���- WHEN THE NON - ENTHALPY OU ■ f - - ' • - HAT • - - - ■ low. ERATURE IS BELOW 55 °F, THE TCP WILL CALL FOR ECONOMIZ " "r Ce ■ CONOMIZER MODE, THE OUTSIDE GENERAL NOTE THIS RESPONSIBILITY SCHEDULE TAKES PRECEDENT REGARDING RESPONSIBI ITY OVER ALL DRAWING NOTES AND COMMENTS 3 4Y�d - �. � / Oct coy APR ISSUE DATE: I REVISIONS: PERMIT DATE: 9/15/071 e BLDNG DEPT 11 -27 -071 I LANDLORD DATE: 9/14/071 I BID DATE: 9/15/071 I MASTERS 7_27_2007 I I Zone 1 95.1 8000 1392 Jul 1900 2.6 8618.0 0.93 TEMPERATURE CONTROLS Zone Terminal Sizing Data - r - • ■ E TO ALLOW FOR FREE COOLING. D.'''. TI-IE MECHANICAL CONTRACTOR MUST INCLUDE IN BASE BID TWO (2) HOURS FOR COMMISSIONING. INCLUDE AN ADDITIONAL 2 -HOURS OF COMMISSIONING PER I-IVAC UNIT FOR THE TEMPERATURE CONTROL SYSTEM. THE MECHANICAL CONTRACTOR WILL BE REQUIRED TO REPAIR/REPLACE COMPONENTS FOUND TO BE DEFECTIVE PRIOR TO RECEIVING A CONTROL NUMBER. THE MECHANICAL CONTRACTOR MUST SCHEDULE COMMISSIONING A MINIMUM OF SEVEN (7) DAYS PRIOR TO COMPLETION OF TEMPERATURE CONTROL INSTALLATION FOR THE NEXT AVAILABLE COMMISSIONING TIME. FAILURE TO DO SO MAY REQUIRE THE MECHANICAL CONTRACTOR TO RETURN TO THE JOB SITE TO PERFORM COMMISSIONING ON A FUTURE DATE AT THE MECHANICAL CONTRACTOR'S EXPENSE. LIGHTING CONTROLS M WARM -UP /COOL -DOWN MODE: Zone Name Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 `F Zone Htg Coil Load (MBH) Zone Htg Water gpm @20.0 °F Mixing Box Fan Airflow (CFM) FOR ONE HOUR BEFORE AND AFTER OCCUPIED HOURS, THE TCP SHALL CALL FOR THE WARM -UP CYCLE. DURING WARM -UP, THE UNIT(S) WILL RUN ONLY IF COOLING AND /OR HEATING IS CALLED FOR TO REACH THE DESIRED SET POINTS. EMERGENCY HEAT MODE: 1 - ' L ` - - r• �°)�)° livi la L -'° Zone 1 41 -4 0.0 0 IF THE PLENUM SENSOR REPORTS A TEMPERATURE UNDER 50'F, THE TCP SHALL GO INTO ALARM AND TURN ALL THE LIGHTS ON IN THE SPACE. SMOKE DETECTOR: Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft Space CFM/ft THE ELECTRICAL CONTRACTOR MUST INCLUDE IN BASE BID TWO (2) HOURS OF COMMISSIONING FOR THE LIGHTING CONTROL SYSTEM. THE ELECTRICAL CONTRACTOR WILL BE REQUIRED TO REPAIR/REPLACE COMPONENTS FOUND TO BE DEFECTIVE PRIOR TO RECEIVING A CONTROL NUMBER. THE ELECTRICAL CONTRACTOR MUST SCHEDULE COMMISSIONING A MINIMUM OF SEVEN (7) DAYS PRIOR TO COMPLETION OF TEMPERATURE CONTROL INSTALLATION FOR THE NEXT AVAILABLE COMMISSIONING TIME. FAILURE TO DO SO MAY REQUIRE THE ELECTRICAL CONTRACTOR TO RETURN TO THE JOB SITE TO PERFORM COMMISSIONING ON A FUTURE DATE AT THE ELECTRICAL CONTRACTOR'S EXPENSE. LIGHTING CONTROLS TO CONSIST OF THREE (3) ZONES. ZONE "A" FOR STOREFRONT AND SIGNAGE. ZONE "B" FOR STOCKING AND ZONE "C" FOR SALES AREA. B * C ZONES SHALL HAVE AN OVERRIDE SWITCH FACTORY MOUNTED ON THE FRONT OF THE TEMPERATURE MONITORING /LIGHTING CONTROL CABINET. CONTROL RELAYS TO BE FACTORY MOUNTED INSIDE THE CONTROL CABINET AND ARE TO BE HARD WIRED TO A TERMINAL BLOCK. FIELD WIRING FROM THE CONTROL CABINET TO THE LIGHT FIXTURE CONTACTORS TO BE BY THE ELECTRICAL CONTRACTOR. TERMINAL BLOCK TO BE LABELED WITH CONNECTION POINTS INDICATED ON PROVIDED WIRING DIAGRAM. WARRANTY AIR DEVICE / ACCESS PANEL SCHEDULE IF THE SMOKE DETECTOR IS ACTIVATED, THE DETECTOR SHALL SHUT DOWN THE UNIT AND THE TCP SHALL GO INTO ALARM. Zone I Cash Room 1 13.3 Jan 2100 1113 0.0 539.0 2.06 SMOKE EVACUATION: IF ANY SMOKE DETECTOR IS ACTIVATE! - ." " _ -' • - =-"-- • "` . SMOKE EVACUATION FAN. Corridor 1 3.0 Ju12100 250 1.1 553.0 0.45 Dressing Rooms 1 8.2 Jan 1900 689 0.0 957.0 0.72 Living Room -a 1 7.7 Jan 1900 646 0.0 569.0 1.14 (1) SYMBOL KEY- (4)DAMPER KEY- FIRST LETTER: S- SUPPLY, R- RETURN, E- EXHAUST, "A" RECTANGULAR DAMPER FURNISHED WITH T- TRANSFER, A- ACCESS. "B" RADIAL OPPOSED BLADE DAMPER FURNISHED (2) SYMBOL KEY-- WITH DEVICE. SECOND LETTER: D- DIFFUSER, R- REGISTER, "C" FIRE DAMPER WITH VOLUME CONTROL FURNISHED G- GRILLE, In-PANEL. WITH DEVICE. (3) FINISH KEY- "D" RADIAL OPPOSED BLADE DAMPER CONTROLLED "A" NI-IITE. FROM FACE. " B" WHITE - G.G. TO FIELD PAINT TO MATCH CEILING (5) BORDER KEY - OR OR WALL WITH ENAMEL FINISH. "A" SURFACE MOUNTED. PRIMED WHITE -WITH FINAL FINISH PER ARCH. "B" LAY -IN PROVIDE WITH PLASTER FRAME FOR FINISH SCHEDULE. PAINTED IN FIELD. DRYWALL MOUNTING. "D" BLACK "G" LAY -IN FRAME FOR T -BAR CEILING. Non -Sales 1 13.5 Jul 2100 1130 1.4 960.0 1.18 Sales #1 1 4.5 Jan 1900 374 0.0 340.0 1.10 Sales #12a 1 2 -6 Jan 1900 217 0.0 400-0 0.54 Sales #12b 1 2.8 Jan 1900 235 0.0 474.0 0.50 Sales #12c 1 3.0 Jan 1900 252 0.0 506.0 0.50 CONTROLS PACKAGE DELIVERY NOTE Sales 1 3.3 Jan 1900 281 0.0 276.0 1.02 Sales#3 1 5.2 Jan 1900 440 0.0 489.0 0.90 Sales #4 1 5.8 Jan 1900 487 0.0 562.0 0.87 Sales #5 1 5.1 Jan 1900 424 0.0 426.0 1.00 THE CONTROLS PACKAGE HAS BEEN PRE - PURCHASED BY THE OWNER WITHIN THE FIRST WEEK OF CONSTRUCTION THE GENERAL CONTRACTOR OR THEIR MECHANICAL SUBCONTRACTOR SHALL PROVIDE THE PHONE AND THE FAX NUMBER OF THE CONTACT PERSON RESPONSIBLE FOR SCHEDULING AND RECEIVING THE CONTROLS PACKAGE AND ACCESSORIES. INCLUDE THE DELIVERY ADDRESS AND ACCESSORIES THAT ARE TO BE SHIPPED, PLUS ANY SPECIAL SHIPPING INFORMATION REQUIRED. ALLOW A MINIMUM OF TWO (2) WEEKS AFTER CONSTRUCTION STARTS FOR DELIVERY UNLESS, SPECIAL ARRANGEMENTS ARE MADE PRIOR TO THE START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL SHIPPING COST INCURRED IF DELIVERY IS REQUIRED PRIOR TO THE STANDARD TWO (2) WEEKS SCHEDULED. THE CONTROLS PACKAGE AND ACCESSORIES WILL SHIP IN ACCORDANCE WITH THE PURCHASE ORDER DATE AND INSTRUCTIONS ISSUED BY OWNER AND THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR IT UNTIL SUCH TIME AS REQUIRED FOR INSTALLATION ON PROJECT. IT IS THE RESPONSIBILITY OF TH E MECHANICAL CONTRACTOR TO VERIFY THAT ALL NECESSARY CONTROLS AND ACCESSORIES HAVE BEEN RECEIVED FOR 1-IVAC EQUIPMENT. - - -- : ' '- _ _ _ t .r .a Sales #6 1 2.5 Jan 1900 209 0.0 233 -0 0.90 Sales #7 1 3.6 Jan 1900 301 0.0 222.0 1.36 Sales #8 1 2.7 Jan 1900 225 0.0 163.0 1.38 THE MECHANICAL/ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR THE PROPER INSTALLATION OF THE CONTROLS AND ACCESSORIES IN ACCORDANCE WITH THESE DRAWINGS AND THE INSTALLATION INSTRUCTIONS INCLUDED WITH THE CONTROLS PACKAGE. WARRANTY BEYOND THE INSTALLATION IS BY OWNER CO. THE UNIT MANUFACTURER WARRANTS ALL CONTROL EQUIPMENT PROVIDED BY OWNER TO BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIAL UNDER NORMAL USE AND SERVICE FOR A PERIOD OF ONE YEAR AFTER COMPLETION OF START -UP. OWNER WILL PROVIDE A SEPARATE SERVICE WARRANTEE FOR CONTROL EQUIPMENT FOR A PERIOD OF ONE YEAR AFTER THE CONTROL NUMBERS) HAVE BEEN ISSUED. GENERAL INSTALLATION INSTRUCTIONS (FOR BIDDING PURPOSES ONLY) Sales #9 1 5.2 Jan 1900 440 0.0 494.0 0.89 Vestibule 1 3.4 Jan 1900 287 0.0 455.0 0.63 CONCEPT 5 115 WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY SEATTLE, WA 98188 gr SYMBOL (1 )(2) MANUF. CATALOG NUMBER NOMINAL SIZE MOUNTING MATERIAL -. N w ()() ° < w W 0 REMARKS FACE NECK QJ u j < g = o w N j j a AIR SYSTEM DESIGN LOAD SUMMARY DETAILED INSTALLATION INSTRUCTIONS WILL SE INCLUDED WITH THE DELIVERY OF THE TEMPERATURE CONTROL PACKAGE. MOUNT CONTROL PANEL ON POWER WALL WHERE INDICATED ON DRAWINGS. REVIEW DETAILED INSTALLATION INSTRUCTIONS AND CONFIRM INSTALLATION LOCATIONS FOR ALL OWNER SUPPLIED EQUIPMENT. EACH COMPONENT 14A5 BEEN PREAI IRED AND LABELED FOR IDENTIFICATI INSTALL ALL COMPONENTS AND ROUTE CABLES THROUGH JOISTS BACK TO TEMPERATURE CONTROL PANEL. CABLES MUST BE RUN INDIVIDUALLY AND INSTALLED WITH 6 INCH SEPARATION WITH SUPPORTS EVER 6 FEET. DO NOT RUN CABLES PARALLEL TO LINE VOLTAGE CONDUIT NOR LAY CABLES ON CEILING (MECHANICAL CONTRACTOR MUST INSTALL TEMPERATURE CONTROL l CABLES IN CONDUIT PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. COORDINATE FINAL DESTINATION LOCATIONS WITH ELECTRICAL CONTRACTOR.) ONCE ALL CONTROL EQUIPMENT HAS BEEN INSTALLED, CALL AND SCHEDULE FOR COMMISSIONING. THIS MUST BE DONE AT LEAST SEVEN (7) DAYS BEFORE SYSTEM IS READY FOR COMMISSIONING, TO SCHEDULE NEXT AVAILABLE COMMISSIONING TIME. SD -1 TITUS FL -20 -HT 2'- LENGTH 2 -SLOT 12 "� • • D - A 0 0 rl :NAl VN SD -2 1c. TITUS 2'- LENGTH u 10 tD • • D - A AO) Ai. DESIGN COOLING DESIGN HEATING 5D -3 TITUS FL -15 -HT 4' - LENGTH 1 -SLOT B o o • • D - A 0 C V COOLING DATA AT Jul 1200 COOLING OA DB / WB 80.8 °F/ 63.6 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F/ 19.2 °F ZONE LOADS Details Sensible (BTU /hr) Latent (BTU /hr) Details Sensible (BTU/hr) Latent (BTU /hr) ir` " . .. `�.�,..........: TI : >. S ;. .,.,,... • ��'• � � f%` " �. .. ii ...........: 4" ,' PLY ... • �-- ........ .. "• • ,�,, .....,.::,'.. - ..._-,.,,,a:�::. � ' "" •''.'!� a � Window & Skylight Solar Loads 0 ft 0 - 0 ft - Wall Transmission 572 ft 534 - 572 5 1132 - SD -5 TITUS SOORL 12 "x12" 6 "� • • D - A 0 DISPLAY ROOMS Roof Transmission 0 5 0 - 0 ft 0 - Window Transmission 0 ft 0 - 0 ft 0 - 5D -6 TITUS TMS 24 ° x24" 6 "0 • • A - C NON SALES Skylight Transmission 0 ft 0 0 ft 0 Door Loads 0 5 0 - 0 ft 0 - Floor Transmission 8618 ft 0 - 8618 ft 1219 - SD- ........ = ' TITUS m 4"x _., 8 II A NO SALES DUI Partitions 0 ft 0 0 ft 0 Ceiling 0 ft 0 .. 0 ft 0 MECHANICAL SYMBOL LEGEND Overhead Lighting 19973 38042 - 0 0 5D -8 TITUS FL-16-HT 3'- LENGTH 1 -SLOT 10 I QI • • A - A 0 Task Lighting 0 W 0 - 0 0 Electric Equipment 7350 W 24338 - 0 0 - SD-q TITUS FL -15 -HT 2'- LENGTH 1 -SLOT 811 • • D A �� People 101 16223 22916 0 0 0 DETAIL DISCRIPTION DETAIL DISCRIPTION DSGNR: MB Infiltration - 0 tl - 0 tl Miscellaneous eous - 0 0 - 0 D SD-10 TITUS FL -20 -HT 4' - LENGTH 1-SLOT 11 o o D - '4 00 Safety Factor 10 %/10% 7914 2292 10% 235 0 SDI DESIGNATION t - 2 25 CFM DIFFUSER TAG TEMPERATURE CONTROL PANEL . >TotalZoneLoads - 87051 25207 - 2587 0 Zane Conditioning 116065 25207 - 164-8 0 Plenum Wall Load 0% 0 - 0 0 Plenum Roof Load 70% 0 - 0 0 - SUPPLY AIR DIFFUSER RETURN/E)CHAUST AIR GRILLE Plenum Lighting Load 30% 20444 0 0 RG -1 PART OF 5D -4 PART OF SD -4 24" OPEN RETURN • • A - A FITTING ROOMS / Return Fan Load 5287 CFM 0 - 1392 CFM 0 Ventilation Load 0 CFM 0 0 0 CFM 0 0 .... i Lc / RG -2 TITUS 355RL 12 "x12" ' • • D A DISPLA ROOMS Supply Fan Load 5287 CFM 0 - 1392 CFM 0 I SCALE:As NOTED Fan Coil Fans 0 0 ' . ' _ / . - i l: ' : / `{ / I '! " - _ / - :: r ' "P! Duct Heat Gain / Loss 0 % 0 0% 0 RG -3 TITUS 355RL 24 "x24" '+ • • '�' A - B NON SALES a> Total System Loads - 136509 25207 - 1648 tl Central Cooling Coil - 136509 25202 - -18544 0 LINEAR SLOT, SUPPLY AIR DIFFUSER SMOKE DETECTOR Preheat Coil 0 0 RG -4 TITUS 355R5 -2 18 "x24" -- • • D - A Terminal Reheat Coils 0 20192 ` ` ® as Total Conditioning - 136509 25202 . 1648 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads RG -5 TITUS MLR-3�1 3'- LENGTH 2 -SLOT • • • D - A /® THERMOSTAT / ROOM SENSOR - - -I *a> , MANUAL BALANCE/ VOLUME DAMPER CODED NOTES: � ' §.; ': ". S Sr�� x- . O '' .;A ' � � y •, al CONTRACTOR TO PROVIDE SIDE CONNECT BOOT INSULATED PLENUM TO ACCOMMODATE DUCT SIZE INDICATED. TITUS FP81 PLENUM BOXES FOR BORDER TYPE 77 ARE REQUIRED. 0 PROVIDE WITH KEYED LOCK. ALL KEYS SHALL BE THE SAME. 0 AIR DEVICE LOCATED IN TOP OF CABINET. REFER TO ARCHITECTURAL DETAILS FOR MORE INFORMATION. Q AIR DEVICES PROVIDED WITH BORDER TYPE 77 FOR FLUSH FINISH. 0 PROVIDE WITH YOUNG REGULATOR MODEL 270 -275 BOWDEN CABLE CONTROL SYSTEM. EQUIPMENT TAG RELATIVE HUMIDITY SENSOR OD MECHANICAL OUTSIDE AIR REQUIREMENTS ROOM PURPOSE OUTSIDE AIR REQUIREMENTS SYSTEM NUMBER CFM PROVIDED EEIVED CITY OF TU KW I LA �'� Z 8 k , = Fti- il'dli 1 CEi` i ER CFM PER 5Q. FT. CFM REQ'D SALES 7105 0.30 2132 VAV -I 700 NM-SALES 1513 0.15 227 VAV -2 610 A B F C 50 O 17 TOTAL 235q VAV -3 > SHEET VAV -4 285 * PROVIDED TAU MALL SUPPLY AIR SYSTEM VAV -5 230 M2.1 TOTAL 23360 * ► I����� .I!C!i !�!�!�!J MI III. W ,IPI,M111411 51-1T. MTL. ELBOW VOLUME DAMP WHERE DAM I NACCESS PROVID SHA TO R.A. MAIN INSULATED FLEXIBLE CONNECTION! (MIN. 3 FT., MAX. 4 FT.) 8" LONG SI-IT. MTL. SECTION SECURED TO DIFFUSER COLLAR W/ MIN. (3) SHT. MTL. SCREWS, MASTIC AND MATERIALS RECOMMENDED BY FLEX DUCT MFGR. AND PER CODE. (MIN.) 1' -0" SHEET METAL PLENUM BOX. BALANCING DAMPER AT F SEE AIR DEVICE SCHED DAMPER TYPE. RETURN AIR REG DER (LAY -IN FRA UIRED LOCATION WOULD BE AT TAKEOFF. /3" EXTENDED IT HANDLE AND COLLAR. URE VINYL FLEX DUCT TO T. MTL. W/ METHOD AND MATERIALS RECOMMENDED BY FLEX DUCT MFGR. AND PER CODE, STRAP CLAMP OVER FLEX DUCT INSULATION * VINYL TO 5HT. MTL. SECURE INSULATION TO DUCT TO FORM A GOOD SEAL. THERMAL INSULATING BLANKET REQUIRED FOR FIRE RATED CEILINGS ONLY. DRY CLG. STEEL MOUNTING FRAME UIRED FOR DRYWALL CEILING IN LLATION. FIRE DAMPER WARE INDICATED ON PLANS. DUCTED RETURN SYSTEM 3 J1 V 1 II 13 INSULATED ROUND DUCT 2 AUGE MINIMUM GAL IZED STEEL PLATE. SECUR 0 FLOOR WITH STEEL M NRY FASTENERS. 26 GAUGE MINIMUM GALVANIZED STEEL PLATE. SECURE TO FLOOR WITH STEEL MASONRY FASTENERS. MINERAL WOOL BATT OR CERAMIC (ALUMINA SILICA) FIBER BLANKET WITH REMOVABLE FORM 3M FIRE BARRIER (CAULK CP -25 OR PUTTY 303) . — PIPE JACKET * INSULATION MINE WOOL BATT OR CE IC (ALUMINA SILICA) F R BLANKET WITH A EMOVABLE FORM PIPE JACKET * INSULATION FLOOR PENETRATION PIPE PENETRATION (FIRE RA OUTSIDE DIMENSION 23 ", 1G1", 17" OR 11" f INSIDE DIMENSION NOTE: ROUGH IN OPENING SIZES: NOMINAL 12 "x 12" = 12 1/2 "x 12 1/2" NOMINAL 18 "x 18" = 18 I /2 "x 18 1/2" NOMINAL 20 "x 20" = 20 1 /2 "x 20 1/2" NOMINAL 24 "x 24" = 24 1 /2 "x 24 1/2" NOMINAL 24 "x 12" = 24 1/2 "x 12 1/2" CABLE TO DAMPER FOR 12x12 DIFFUSERS, MOUNT "YOUNG" DAMPER REGULATOR ON CHANNEL "C" CHANNEL REINFORCING BY G.C. AROUND OPENING DRYWALL CEILING STEEL MOUNTING FRAME UNIT HEA SECURED T MINIMUM OF BRACKETS. BRA HEATER MANUFAC RECOMMENDATION. AS LINE UBRICATED PLUG ,VALVE (TYP ICAL) 5HALL BE ALL WITH A 5 PER ER'S SUSPENSION SIDE OF WASHER SPECS DA UNION CONNECT TO GAS TRAIN PROVIDED WITH EQUIPMENT DIRT LEG REMOVABLE END CAP ROOF PIPES MANUFACTURE INDUSTRIES OR VERIFY USE OF D PLACEMENT WITH LA PRIOR TO BIDDING. - 1" THICK LAYER OF ROOF FELT EXISTING ROOF DECK ELECTRIC UNIT HEATER D AS Y MIRO L. AND DRD ///Z,////// SCALE : NONE ROOF DECK DUCT TAKEOFF (SQUARE) MAINTAIN MAXIMUM HEIGHT ABOVE FINISHED FLOOR. (SEE PLAN FOR APPROX. H AND COORDINATE DUCT WITH FIELD CONDITIO ZONE DAMPER WIRING DIAGR GHT UTING 16" DAMPE TRANSFORMER 24/120V, 40 VA 120V BY E.G. RTU DUCT CONNECTION C- 4010PC8 = 8" YRC- 4010PC12 = 12" YRC- 40751 = 16" FILL VOID SPACES WITH BATT INSULATION FLANGED AND GASKETED JOINT OR DUCT CONNECTION AND RE- ENFORCEMENT IN ACCORDANCE W/ SMACNA 2" W.G. CLASS, SEAL NON - GASKETED TRANS- VERSE JOINTS IN ACCORDANCE N/ SMACNA CLASS "C" (TYP.) MAIN DUCT TAPE DOWN EXTERNAL INSULATION FASTEN W/ MIN. (3) SHT. MTL. SCREWS, SEAL N/ DUCT TAPE AND MASTIC 1 1/2" WRAPPED INSULATION NALL LINE PIPE POLYSULFIDE SEALANT-- PIPE JACKET * INSULATION 1;:i POLYSULFIDE SEALANT- PIPE CLEAN OUT C I" TRAPPED PVC CONDENSATE DRAIN 5" MIN. TRAP DEPTH SPLASH BLOCK SCALE : NONE SQUARE TO ROUND WALL PENETRATION FLOOR PENETRATION ALL DUCT LINER TRANSVERSE EDGES TO BE COATED W/ ADHESIVE IN ACCORDANCE W/ SMACNA STANDARDS (TYP.) 1" ACOUSTICAL LINING 4 0011111 AIR FLOW CONICAL OR BELL MOUTH SPIN- IN FITTING, SEAL AIRTIGHT W/ MASTIC VOLUME DAMPER AS INDICATED ON PLANS. PROVIDE WITH LOCKING QUADRANT 18" LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION PIPE SLEEVE 3/4" THICK FIRESAFING INSULATION PIPE JACKET * INSULATION FLOOR SLAB PIPE SLEEVE 3/4" THICK FIRESAFING INSULATION PIPE PENETRATION (STANDARD) ;rro UNIT RE NEOPNE PAD MANUFACTURERS ROOF CURB FLASHING ROOF STEEL A DUCT, PIPING, OR ELECTRICAL CONNECTIONS TO UNIT 8 W CURB SHALL V E FLEXIBLE CONNECTIONS. CUT INSULATION, GYPSUM BOAR ROOFING N SULATION, AND METAL DECKING PENETRATIONS TIGHT TO ITEM ETRATING ROOF. PACK ALL PENETRATION OPENINGS WITH GLASS FIBER INS TION. RTU CONDENSATE AND CURB FLANGED AND GASKETED JOINT OR DUCT CONNECTION AND RE- ENFORCEMENT IN ACCORDANCE W/ SMACNA 2" W.G. CLASS, SEAL NON- GASKETED TRANS- VERSE JOINTS IN ACCORDANCE W/ SMACNA CLASS "C" (TYP) �1 MAIN DUCT FASTEN N/ MIN. (3) 514T. MTL. SCREWS, SEAL N/ DUCT TAPE AND MASTIC ROUND RIGID DUCT 1 1/2" WRAPPED INSULATION ROUND TO ROUND 5020CC ROUND DAMPER OR 830ACC RECTANGULAR OPPOSED BLADE DAMPER .4 -18" LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION ALL DUCT LINER TRANSVERSE EDGES TO BE COATED N/ ADHESIVE IN ACCORDANCE W/ SMACNA STANDARDS (TYP.) CONICAL, SADDLE OR TAP FITTING, SEAL AIRTIGHT W/ MASTIC VOLUME DAMPER AS INDICATED ON PLANS. PROVIDE WITH LOCKING QUADRANT RIGID DUCTWORK FLEXIBLE DUCTWORK X ii r'•L gradir S '''''../„.._ 411°P J_ 44011111 AIR FLOW DAMPER CABLE CONTROL SYSTEM SINGLE VANE L L DOUBLE VANE SCALE : NONE AIR FLOW RUNNER AIR FLOW RUNNER GAS PIPING DROP SINGLE VANE SCHEDULE R SP A. SMALL 2" 1 1/2" 24 LARGE 4 1/2" 3 1/4" 22 DOUBLE VANE SCHEDULE R1 R2 L SP GA. SMALL 2" 1" 1/6" 2 1/2" 26 LARGE 4 1/2" 2 1/4" 2 1/4" 3 1/4" 24 NOTE: SMALL = UNDER 24 "x24" LARGE = 24 "x24" AND ABOVE USE GALVANIZED VANES FOR GALVANIZED DUCTS. 1) THE 270 -275 BOWDEN CABLE CONTROL SYSTEM IS DESIGNED FOR USE WITI -I EXTERNALLY CONTROLLED ROUND OR RECTANGULAR DAMPERS, AND CAN BE MOUNTED IN A WIDE VARIETY OF LOCATIONS INCLUDING CEILING JOISTS, LAY -IN CEILINGS, BEI-4IND GRILLES, ON OR INSIDE 01I -TER VARIOUS TYPES OF DIFFUSERS, ETC. 2) CABLE S1 -1ALL CONSIST OF BOWDEN CABLE 0.054" STAINLESS STEEL CONTROL WIRE ENCAPSULATED IN 1/16" FLEXIBLE GALVANIZED SPIRAL WIRE SI- IEATI -I. 3) LOCKING RACK AND PINION GEAR DRIVE SHALL BE CONSTRUCTED OF 14 GAUGE STEEL AND SHALL- BE USED TO CONVERT ROTARY MOTION INTO PUSH -PULL MOTION. 4) CONTROL 51-1AFT SI -TALL BE "D" -STYLE FLATTENED 1/4" DIAMETER WITI4 265° ROTATION PROVIDING 1 -1/2" LINEAR TRAVEL CAPABILITY. CAULK AND SEAL ALL PENETRATIONS LOCKING RACK * PINION OPERATOR MOUNTING BRACKET LINEAR SLOT DIFFUSER WITI -1 PLENUM BOX SOCKET WRENCH STEEL BLADES WITH INTERLOCKING JOINTS FUSIBLE FIRE LINK DUCT (TYP.) VERTICAL FIRE DAMPER PIPE SUPPORT BOLT T 'SLEEVE (TYP.) MOUNT SLEEVE IN BLDG. CONSTRUCTION, SLEEVE TO BE OF GAUGE AS RECOM- MENDED BY MFGR. FOR U.L. APPROVAL AND CODE COM- PLIANCE RETAINING ANGLES, SIZE AS RECOM- MENDED SY MFGR. NOTE: ROVIDE ACCESS DOOR I ACCESSIBLE LOCATION RESETTING OF DAMPER IBLE LINK. BION TS, EACH E WITH LOCK R MANUF. SING MOUNTING ATTACHED TO UNIT. UNIT HEATER AIR FLOW ROOF MEMBRANE RECEIVED CITY OF TUK VILA Q 8 L6Ul �!;'ri6'dbd 1 CEiii ER W hC i= W CC ra 0 Z O W cc ABFC50017 SHEET 1" ACOUSTICAL LINING MAIN DUCT ALL DUCT LINER TRANSVERSE EDGES TO BE COATED W/ ADHESIVE IN ACCORDANCE NJ SMACNA STANDARDS (TYP.) BRANCH DUCT A 3' -0" INSULATED FLEXIBLE CONNECTION. 8" LONG 51-1T. MTL. SECTION SECURED TO DIFFUSER COLLAR W/ MIN. (3) SI-IT. MTL. SCREWS, MASTIC AND MATERIALS RECOMMENDED BY FLEX DUCT MFGR. AND PER CODE. TRANSITION FROM DUCT SIZE TO DIFFUSER NECK SIZE AS NECESSARY. CLIPPED ON DIFFUSER RODS SUPPLY AIR DIFFUSER TYPICAL DIFFUSER MOUNTING SCALE : NONE T312 T -STAT FLANGED AND GASKETED JOINT OR DUCT CONNECTION AND RE- ENFORCEMENT IN ACCORDANCE W/ SMACNA 2 W.G. CLASS, SEAL NON- GASKETED TRANS- VERSE JOINTS IN ACCORDANCE k4/ SMACNA CLASS "C" (TYP.) AIR FLOW VOLUME DAMPER AS INDICATED ON PLANS. PROVIDE WITH LOCKING TI QUADRANT 18 LONG ORANGE MARKER TAPE ATTACHED TO DAMPER TO IDENTIFY LOCATION SI-IT. MTL. ELBOW REQUIRED VOLUME DAMPER LOCATION WHERE DAMPER WOULD BE INACCESSIBLE AT TAKEOFF. PROVIDE W/3" EXTENDED SHAFT, HANDLE AND COLLAR. SECURE VINYL FLEX DUCT TO SHT. MTL. W/ METHOD AND MATERIALS RECOMMENDED BY FLEX DUCT MFGR. AND PER CODE, STRAP CLAMP OVER FLEX DUCT INSULATION * VINYL TO SHT. MTL. SECURE INSULATION TO DUCT TO FORM A GOOD SEAL. THERMAL INSULATING BLANK REQUIRED FOR FIRE RATED CEILINGS ONLY. DRYWALL CLG. STEEL MOUNTI FRAME REQUIRED FOR DRYWAL CEILING INSTALLATION. FIRE DAMPER NHERE INDICATE ON PLANS. TUB SHEET METAL DUCT 6" UP ME SIZE AS NECK OF GRILLE. URN AIR REGISTER Y -IN FRAME) NON- DUCTED RETURN SYSTEM THERMAL INSULATING BLANKET REQUIRED FOR FIRE RATED CEILINGS ONLY. DRYWALL CLG. STEEL MOUNTING FRAME REQUIRED FOR DRYWALL CEILING INSTALLATION. FIRE DAMPER WI -IERE INDICATED ON PLANS. NOTE: ALL DIFFUSERS ARE 4 -WAY BLOW UNLESS NOTED OTHERWISE. DIRECTIONAL BLOW CONVERTERS WILL 5E PROVIDED BY I- IOLLISTER FROM LOES FOR DIFFUSERS THAT ARE 1 -WAY, 2 -WAY OR 3 -WAY BLOW AS DESIGNATED ON PLANS BY SHADED AREA. AIR BALANCE REVIEW CI- IEGKLIST PROJECT INFORMATION DIVISION: CENTER: NO#: CONTRACTOR: DATE: FAX # : "A COPY OF THIS CHECKLIST MUST BE COMPLETED AND INCLUDED WITH BALANCE REPORT" SYSTEMS TO CHECK SYSTEM INDEX ACCEPTABLE (CHECK) El INDEX NO# SYSTEMS: i. VAV BOXES 2. WATER SOURCE HEAT PUMPS 3. ROOFTOP UNIT 4 . SPLIT DX OR BUILT -UP CW 5. FAN FOR CEILING, F -1 OR ETC. 6. ELECTRIC BASEBOARD /UNIT 14EATER 7. TOILET D(HAUST FAN, EF -1 UA UNACCEPTABLE NOT ACCEPTABLE (X) • CI -NECK ALL THAT APPLIES (SEE SYSTEM INDEX) 1 2 3 4 5 6 7 , UA • • ❑ • • a ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ REPORT PREPARED BY INDEPENDENT AABC OR NEBB LICENSED CONTRACTOR (LICENSE it AND SIGNATURE REQUIRED) CONFORMANCE CERTIFICATE / PERFORMANCE GUARANTY REGISTERED WITH NATIONAL I- IEADQUARTERS EQUIPMENT LIST AND CALIBRATION DATE (WITHIN 6 MONTHS OF TEST) MAKE AND MODEL # OF EACH PIECE OF EQUIPMENT TESTED MOTOR NAMEPLATE DATA 0 ❑ ❑ • • • • • • • • • • • • • • • • ❑ • • ❑ ❑ ❑ • • • MANUFACTURER OF MOTOR MOTOR HP/BHP UNIT VOLTAGE MOTOR AMPERAGE (AMPS) KILOWATTS (KW) HEAT MOTOR RPM SERVICE FACTOR (SF) SHEAVE SIZE/BORE SIZE NUMBER AND SIZE OF BELTS UNIT FIELD MEASUREMENTS • ❑ ❑ ❑ • • • • • • • • • • • ❑ ❑ ❑ • • • • • • • • ❑ ❑ ❑ • • ❑ ❑ FIELD VOLTAGE WITH EACH PHASE FOR 3 -PHASE MOTORS AMP DRAW EACH PHASE FOR 3 -PHASE MOTORS KILOWATTS (ELECTRIC HEATER ONLY) FAN RPM EXTERNAL STATIC PRESSURE - INLET SIDE EXTERNAL STATIC PRESSURE - DISCHARGE SIDE WATER GPM CONDENSER/CHILLED /HEATING SUPPLY WATER TEMPERATURE CONDENSER/CHILLED /HEATING RETURN WATER TEMPERATURE CONDENSER/CHILLED /HEATING DESIGN AND ACTUAL CFM I S (WITHIN 5% OF DESIGN) AS FOLLOWS: • • ❑ • • • • ❑ ■ • • ❑ ❑ • • • • • • • • ❑ ❑ • • • • • • AT EACH SUPPLY DIFFUSER AT EACH RETURN AIR GRILLE FOR DUCTED RETURN TOTAL SUPPLY BY DUCT TRAVERSES TOTAL RETURN /RELIEF BY DUCT TRAVERSES TOTAL OUTSIDE AIR AND METHOD OF TESTING O.A. AMOUNT PLAN INDEXING EACH DIFFUSER AND GRILLE TESTED VERIFICATION OF OPERATIONAL STATUS ❑ ❑ • • • • • • ❑ ■ ■ • • • ❑ ❑ ❑ • • ❑ ❑ • • • SPACE TEMPERATURE AND SET POINT AFTER BALANCE SUPPLY TEMPERATURES (AT 100% COOLING $ 100% HEATING) OUTSIDE DB /LOB READING AT TIME OF BALANCE ECONOMIZER SETTING (A/B /C /D) IN ROOFTOP UNITS ADJ. $ VERIFY ECONOMIZER EXHAUST FAN GOES ON AT 60% O.A. MAXIMUM CFM RELIEF WITH ECONOMIZER AT 100% O.A. UNIT HEATER OPERATIONAL STATUS AND SET POINT TEST OF SUPPLY AIR FAN SHUTDOWN IN ALARM SEQUENCE TEST OF SMOKE EXHAUST FAN IN ALARM SEQUENCE • • • • • • • • • • • • • • • • • • • • • ❑ ❑ ❑ ❑ • • ❑ • 0 THE A/B REPORT SUBMITTED COLUMN HEADED U UA' FOR THE ABOVE LOCATION HAS BEEN REJECTED. NOTE CHECKS IN (UNACCEPTABLE) AND REMARKS BELOW. FOR THE ABOVE LOCATION IS APPROVED. DATE: • THE A/B REPORT SUBMITTED APPROVED BY: REMARKS: At REV 1/97 i i DIVISION 15 - IECHANICAL SECTION 15000 BASIC MECHANICAL REQUIREMENTS A. _M I, THE ABBREVIATION OWNER WHEREVER It APPEARS IN THESE MECHANICAL. DRAWINGS AND /OR SPECIFICATION SHALL REFER TO 'ABERCRO MBIE 4 FITG -I, INC,'. ANY REFERENCE TO TENANT'S OR OWNER'S CONSTRUCTION MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO OWNER. 2, DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL. OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 3. THE CONTRACTOR FOR 11-115 DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEN DRAWINGS FOR AU. DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF 1415 WORK AND THE WORK OF 1415 SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT 15 THIS CONTRACTORS RESPONSIBILITY TO PROVIDE 1415 SUBCONTRACTORS •1114 A COMPLETE SET OF BID DOCUMENTS. 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF HIS WORK AND THE WORK OF HIS SUB- CONTRACTORS WORK TO COMPLY WITH THE OWNERS SCHEDULE AND THE PROJECT COMPLETION DATE. 5. T1415 CCNTRACTOIR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WINCH ARE NOT COVERED IN THE BID DOCUMENTS SHALL BE BROUGHT TO OWNER'S ATTENTION. THERE ARE NO SUBSTITUTIONS. SUBMITTAL Of BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET TNE INTDIT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 6. REFER. 5PONSIBILITY SCHEDULE ON THE MECHANICAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR 11 rr1 MICH MAY AFFECT BID. B. GENERAL EQUI EIENTS: I. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN CNE SHALL FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SWAN ON 114E DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH 15 OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND M941C14 USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SMALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. MERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM I4 t4 THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DECREED al THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL ME.CHANICAL WORK SHALL SE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. T1415 CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. THIS CONTRACTOR SHALL PROVIDE AU- LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN al THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR OWNER SHALL BE PROVIDED BY THE MEOI ' O NTRACTOR ALL WORK SMALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. 6, UNLE SPECIFIC-ALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WIG-LEVER IS MORE STRINGENT. C. DAME I. ALL WORK WALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALT14 : ODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. 11415 CONTRACTOR %TAU- INQUIRE INTO AND COMPLY WITH ALL. APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SMALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF NESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE OMER TO THE CONTRACTOR. D. LICENSES. PERMITS. INSPECTIONS & FEES: I, THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. a LL HE OMER'S CONSTRUCTION MANAGER A CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF E. TRADE ES. MANUFACTURERS AND SHOP DRAWINGS: WHERE f NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED SE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPI7NSE, 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO OWNER'S CONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL DE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING PAYS FOR OWNER'S CONSTRUCTION MANAGER'S REVIEW WITI4OU T CAUS ING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND THE SUB- CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DIRAHINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. F. G 11415 CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER 1-115 CONTRACT AND SHALL. MAKE GOOD, REPAIR OR REPLACE 415 OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONT I THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY OWNER'S CONSTRUCTION MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. OWNER SHALL PROVIDE A COMPLETE 12 MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY OWNER AND OWNER'S VENDORS. 11415 CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONEYS LD BE INCLUDED IN THE BID. G. RECORD DRAWINGS: 3. 4. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. B. C. LOCATION OF CONGEALED PIPING VALVES AND DUCTS. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL SE STAMPED 'DO NOT REMOVE' AND SHALL BE PLACED IN A DRAWING TUBE LOCATED NEXT TO THE ELECTRICAL PANEL. SEE ARCHITECTURAL DRAWINGS FOR EXACT TUBE LOCATION. H. DISCREPANCE$ IN DOCUIIENT$i DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE NE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE OWNER'S CONSTRUCTION MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, OWNERS CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDmONS SHALL BE FINAL WITH NO ADDmONAL COMPENSATION PERMITTED. • • ,. • • - .an,r11'43P �. I• • wJ_ • • 11415 CONTRACTOR IS TO INCLUDE IN HIS BID ALL- PURSING AND SPRINKLER SERV - THE - TO KEEP OR MUST TO ANY SHUT DOWN OF THE 14VAC, PLUMBING OR FiRE PROTEGTI 114! OPERATING PHASE OF THE STORES 14VAC, 1 5 CONSTRUCTION MANAGER AND • J. I. THIS CONTRACTOR BY THE GENERAL CONTRACT 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL FIXTURES, PIPING, 14VAC UNITS, REFRIGERANT - - - - , 11415 PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT EXTRANEOUS ITEMS IN THE SPACE OR PATO- ED/REPAIRED TO MAT CONCRETE, OR TO BE RESPONSIBLE FOR NE COORDINATION OF NE DEMOLITION OF EXISTING INATE WITH THE GENERAL CONTRACTOR ANY EXISTING IBLE FOR, ( NOT E DEMOLITION PROVIDED REQUIRED TO BE LEFT INTACT. OF ALL EXISTING FIRE PROTECTION, PLUMBING C. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED BE REMOVED AND THE ROOF PATCHED. ALL BE REMOVED AND ROOF/WALL/FLOOR IN 114E FLOOR, EMBEDDED IN WHEN THEY ARE NOT TO REMOVAL ROOF NOT APPLICABLE TO THE NEW STRUCTURE, EXISTING ABANDONED PIPES, DUCTS, OR 15LE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. K. SLEEVES: THIS CONTRACTOR WALL PROVIDE SLEEVES TO PROTECT EQUIPMENT CR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGI4IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH 141T14 EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2 ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE 'RTV FOAM, '311' FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. L HANGERS; I. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, G- CLAMPS WiTH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. M. FINAL HVAC INSPECTIONS: ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, OWNER SHALL HAVE AN INDEPENDENT I4VAC CONTRACTOR INSPECT THE FINISHED 14VAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WELL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. END OF SECTION 15000 A. SCOPE OF W THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDmONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: B. C. D. E. F. COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. FIXTURES AND EQUIPMENT AS SCHEDULED, COMPLETE NATURAL GA5 PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). CONDENSATE PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). TESTS AND ADJUSTMENTS. 2. BEFORE STARTING WORK, 11415 CONTRACTOR SHALL EXAMINE NE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3, RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. EQUIPMENT AND INSTALLATION REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES. AMERICAN STANDARD, KOHLER AND CRANE ARE CONSIDERED ACCEPTABLE AS EQUALS. 2, SANITARY PIPING: A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE, IF REQUIRED BY LOCAL CODE OR MALL. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STEE.. ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY NE LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER TRADES. SUBSTITUTIONS MUST BE LISTED AND QUALIFIED IN BID. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES OF TENANTS IN SPACES BELOW, WHEN APPLICABLE_ INSULATION TO BE AS SPECIFIED FOR WATER PIPING. CONDENSATE PIPING SHALL BE TYPE 'L' DRAWN COPPER TUBE WITH 0.5-5 TIN - ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. PVC MAY BE SUBSTITUTED IF LOCAL CODE PERMITS. B. 11. 13. B. C. 3, POTABLE WATER PIPING SHALL BE AS FOLLOWS: A BELOW GRADE: TYPE 'K', ANNEALED TYPE TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. B. ALL OTHER; TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND q5-0 TIN - ANTIMONY SOLDER 4- PIPING OF DISSIMILAR METALS MUST BE DI- ELECTRICALLY SEPARATED. 5. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY OWNER'S CONSTRUCTION MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS CR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERA:HUTY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: A, SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. B , T7=5T WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDING EQUIPMENT SUPPLIED. 6, INSULATE ALL HOT WATER, COLD WATER AND CONDENSATE PIPING WITH I' THICK (K -O.23 @ 75 'F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. 7. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH I/2' ARMSTRONG 'ARMAFLEX' PIPING INSULATION OR TRUEBRO MODEL 102W 'HANDI LAV GUARD" INSULATION KIT. INSTAL. ALL NECESSARY PiPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. q, STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. 10. CLEANOUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL. CODES. NALL COVERS ARE TO BE STAINLESS STEEL AND FLOOR COVERS ARE TO BE BRASS. ESCUTCHEONS SNAI..L BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALES, FLOORS, AND CEILINGS IN FINISHED AREAS. 12. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS MUD...LS; A, TEST WATER PIPING AT 100 PSIG FOR SIX HOURS. B. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. FL.A.SHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO TiHE LANDLORD'S CRITERIA USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE 14. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE REFER TO PLANS TO DETERMINE IF WATER METER IS REQUIRED, 15 FIXTURES IN PIPE SLEEVES SHALL BE FLUSHED INTO WATERPROOF MEMBRANE AND PIPE SLEEVES SHALL EXTEND A MINIMUM OF 4' A.F.F. PER THE MEMBRANE MANUFACTURERS REGOMMENDATION5 C. GAS PIPING: 1. FURNISH AND INSTALL A COMPLETE GAS PIPING SYSTEM IF APPLICABLE, REFER TO PLANS TO DETERMINE IF A GAS SYSTEM IS REQUIRED. 2. GAS LINES SHALL BE BLACK STEEL, SCHEDULE 40, ASTM A-53 GRADE B MATERIAL, WELD FITTINGS PN WELDED 2' OR LARGER PIPING- S, FURNISH AND INSTALL A GAS COCK, DIRT LEG, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT. 4. PiTCH PIPING AT A UNIFORM GRADE OF 1/4' IN 15 FEET UPWARD IN DIRECTION OF FLOW. SUPPORT PIPING EVERY 5 FEET. SUPPORT AS REQUIRED BY LANDLORD CRITERIA, AS DETAILED ON DRAWINGS, OR BY STANDARD INDUSTRY PRACTICE, 1.1I4ICWEVER IS MORE STRINGENT. 5. GAS PIPING EXPOSED ON ROOF MUST SE PAINTED WIT14 RUSt- INHIBITING PAINT. 6. GAS PIPING INSTALLED IN RETURN AIR PLENUMS SHALL BE SLEEVED AND VENTED OR WELDED IN ACCORDANCE P11114 THE LOCAL GAS COMPANY, LOCAL CODE, AND APPLICABLE NFPA 54 CODES. 7. TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NFPA 54 CODES. B. CONTACT AND COORDINATE GAS SERVICE, METER AND REGULATOR REQUIREMENTS WITH THE LOCAL GAS COMPANY AND THE MALL'S OPERATIONS MANAGER PRIOR TO BID. INCLUDE INSTALLATION COST OF GAS METER AND REGULATOR IN BID. END OF SECTION 15200 A- SCOPE OF WORK: 2. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A, INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE 100X SPRINKLER COVERAGE IN ACCORDANCE WITH EXISTING CONDITIONS, NFPA -13, LATEST EDITION ENFORCED BY LOCAL CODES, LANDLORD'S CRITERIA, AND INSURANCE CARRIERS FOR THE MALL. 5- I. 3. 8. q. 11. B. C. D. E. F. B. C. D. C. D. S. DIVISION 15 - MECHANICAL SECTION 15200 PURIM DIVISION 15 - iECHANNICAL SECTION 15300 FIE PROTECTION THIS CONTRACTOR MUST USE A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR TO PERFORM ALL FIRE PROTECTION WORK. ALL COSTS MUST BE INCLUDED IN THIS CONTRACTORS BID. FIRE PROTECTION CONTRACTOR MUST COMPLY WITH ALL SECTIONS OF THIS SPECIFICATION AND INCLUDE SAME IN BID. INCLUDE MALL SHUT - 1DOWN FEES AS REQUIRED. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. DESIGN DRAWINGS, HYDRAULIC CALCULATIONS, SUBMITTALS AND APPROVALS. PERMITS, FEES, AND CHARGES. TESTS AND TEST CERTIFICATES. FIRE EXTINGUISHERS WITH TAGS. 3, BEFORE STARTING WORK, 11415 CONTRACTOR SHALL EXAMINE 114E ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, MD EQUIPMENT P11114 OT14ER CONTRACTORS TO AVOID INTERFERENCE'S AND CONFRONTATIONS. CONTRACTOR SHALL USE APPROVED INDUSTRY FIRE SPRINKLER STANDARDS FOR REUSING EXISTING FIRE SPRINKLER BRANCHES AND SUBMIT CALCULATIONS TO OWNER'S CONSTRUCTION MANAGER UPON REQUEST OR REWORK SYSTEM TO OWNERS CONSTRUCTION MANAGER'S SATISFACTION. 4, RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACIUTATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. CONFIRM WITH LANDLORD REQUIREMENTS FOR LIFE SAFETY SYSTEM IF PROVIDED. B. SHOP DRAWINGS: I. THIS FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS FOR 1415 WORK. SUBMIT SIX (6) COPIES TO GENERAL CONTRACTOR FOR APPROVAL AND ONE (I) COPY TO OWNER FOR REVIEW AND APPROVAL. 2. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, HYDRAULIC CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES WAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE SEEN RECEIVED. 3. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE FORWARDED TO THE LANDLORD'S AGENT AND TO OWNER'S CONSTRUCTION MANAGER C. EQUIPMENT AND INSTALLATION: SPRINKLER HEADS: A. ALL SPRINKLER HEADS SHALL BE NEW (HEADS IN EXISTING OWNER STORES ARE NOT TO BE REPLACED UNLESS NOTED OTHERWISE). HEADS SHALL BE U.L., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER CO., GLOBE, GRINNELL, RELIABLE, STAR, OR VIKING. ALL SPRINKLER I-IEADS SHALL BE RATED FOR 1657 UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. ALL SPRINKLER HEADS ARE TO HAVE A FACTORY APPLIED COLOR FINISH. VERIFY HEAD TYPES AND COLORS 14174 OWNER'S CONSTRUCTION MANAGER AND SUBMIT W1114 SPRINKLER DRAWINGS FOR PERMIT. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS. 'SALES' AREA SPRINKLER HEADS ARE TO BE CONCEALED HEADS, WHITE OR BLACK FINISH WITH WHITE ESCUTCHEON. REFER TO FIRE PROTECTION SHEETS. 'SALES ROOM I2' SHALL HAVE RECESSED HEADS WITH CUSTOM FINISH TO MATCH CEILING, BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL AND MUST BE APPROVED BY THE OWNER'S CONSTRUCTION MANAGER PRIOR TO ORDERING AND ANY INSTALLATIONS. ALL EXPOSED PIPING SHALL BE PAINTED WHITE IN COLOR AND MUST BE COORDINATED WITH ALL TRADES. 2 PORCH AREA SPRINKLER HEADS ARE TO BE WHITE CONCEALED TYPE WITH WHITE ESCUTCHEON. SASE BID TO BE RELIABLE MODEL 'G' OR EQUAL 3. "NON-SALES" AREA SPRINKLER HEADS ARE TO BE WHITE RECESSED HEADS WITH WHITE ESCUTCHEON. BASED ON RELIABLE AND ALTERNATE MAY BE VIKING OR GRINNELL 4, "NON - SALES' OFFICE AND LAVATORY AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE. 'MALL BULKHEAD' AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WiTH WHITE COVER PLATE. E, PROVIDE TWO (2) SPARE SPRINKLER HEADS OF EACH TYPE. 2. PIPING: A salt DuLE 40, BLACK STEEL PIPE, ASTM A-53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI 13-36 -10-70 FOR WROUGHT STEEL PIPE. B. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. GALVANIZED OR BLACK MALLEABLE IRON WiTH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. VICTUALIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. A FIRE PROTECTION SYSTEM TAP IS NORMALLY FURNISHED BY THE LANDLORD. VERIFY IN FIELD PRIOR TO BID. SPRINKLER SPACING SHALL NOT EXCEED I30 SQ. FT. IN 'SALES' AREAS AND 100 SQ. FT. IN 'STOCX" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA AND LOCAL CODES IF MORE STRINGENT. PIPE SIZING WALL BE BASED ON NFPA 13 ORDINARY HAZARD CLASSIFICATION_ 4, ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH LIGHTS, DUCTS, PIPES, STORAGE DECK, Etc. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER LINES, LIGHTS, DIFFUSERS, GRILLES MD REGISTERS PRIOR TO INSTALLATION. 5, MERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. 6. FURNISH AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR INSURANCE CARRIER. COORDINATE LOCATION Wm4 LOCAL FIRE PROTECTION OFFICIAL PRIOR t0 ROUGH IN. 7, WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING S t1M SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. PROPERLY COMPLETED AND SIGNED 'SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES' SHALL BE FURNISHED To THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND OWNER'S CONSTRUCTION MANAGER. SPRINKLER HEADS LOCATED IN CEILINGS OR WALLS BLOW S'-O' ABOVE TUE FINISHED FLOOR AND ABOVE STORAGE DECKS ARE TO BE RECESSED. 10. FURNISH AND INSTALL 10 LB. TYPE 'ABC" FiRE EXTINGUISHERS, WITH CA3INETS IF REQUIRED, AND AT LEAST A '2AIOBC' RATING. LOCATIONS TO BE ESTABLISHED IN THE FIELD BY THE LOCAL FIRE PROTECTION OFFICIAL. MAXIMUM TRAVEL DISTANCE BETWEEN EXTINGUISHERS SHALL BE 75 FEET OR LESS AS REQUIRED BY LOCAL CODES. SPRINKLER CONTRACTOR IS RESPONSIBLE FOR THE ENTIRE SPRINKLER SYSTEMS. WATER TIGHT INTEGRITY UNTIL SUCH TIME AS OWNER OCCUPIES THE FACILITY. ANY WATER DAMAGE PRIOR TO THIS TIME SHALL BE THE SOLE RESPONSIBILITY OF THIS CONTRACTOR. END OF SECTION 15300 A. SCOPE OF WORK: 1. 3. 11415 CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR 114! MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JCS CONDITIONS, TO INCLUDE, BUT NOT BE UNITED TO THE FOLLOWING: A. B. C. D. F. HVAC UNITS, EQUIPMENT, AND APPURTENANCES (UNLESS NOTED OTHERWISE). DUCTWORK, FITTINGS, DAMPERS, AND INSULATION, HYDRONIC PIPING. (AS APPLICABLE, REFER TO PLANS). REFRIGERANT PIPING (AS APPLICABLE, REFER To PLANS). CURBS, ROOFING, AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). TESTING, ADJUSTING, AND BALANCING. 2, BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOB SITE AND EXAMINE THE ARCHITECTURAL, STRUCTURAL MECHANICAL ELECTRICAL ECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES To MEET STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL B . HVAC EQUIPMENT: 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED BY OWNER AS SCHEDULED UNLESS NOTED OTHERWISE. REFER TO PLANS FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT W1114 ALL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3_ EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. 4. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO PROTECT ENTIRE UNIT. PROVIDE CONDENSATE PUMPS, AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. 5, REFER TO THE AIR DEVICE / ACCESS PANEL SCHEDULE ON SHEET 112.1 FOR AIR DEVICE'S TO BE SUPPLIED BY OWNER. C. EQUIPMENT FURNISHED BY OWNER THE FOLLOWING EQUIPMENT IS FURNISHED BY OWNER AND INSTALLED BY THIS CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. REFER TO RESPONSIBILITY SCHEDULE AND PLANS FOR APPLICABILITY. B. C. D. DIVISION 15 - MECHANICAL SECTION 15500 HEATING, VENTILATION, & AIt CONDITIONING RTU'S, AHU'S, VAV BOXES, ROOF CURBS, MIXING BOXES, POWER EXHAUST FANS. TOILET EXHAUST FANS, RELIEF FANS, RETURN AIR FANS. BASEBOARD, CABINET AND ELECTRIC UNIT HEATERS. TEMPERATURE CONTROLS D. TOLET EXHAUST SYSTEM: I. ALL DUCTWORK, ROOF OPENINGS AND CAPS AND /OR CONNECTIONS TO LANDLORD SYSTEM NECESSARY FOR A COMPLETE TOILET EXHAUST SYSTEM TO BE PROVIDED BY THIS CONTRACTOR. E. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED: 1. 3. NO DUCTWORK SHALL BE FABRICATED PRIOR TO JO3 SITE VISIT AND APPROVAL BY THE GENERAL CONTRACTOR. A SKEtCH MUST BE SUBMITTED INDICATING SIGNIFICANT DEVIATIONS FROM DESIGN AND MUST BE APPROVED BY OWNER'S CONSTRUCTION MANAGER PRIOR TO FABRICATION OR INSTALLATION. 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE W1114 SMACNA 'HVAC DUCT CONSTRUCTION STANDARDS' OF THE LATEST EDmON. WHERE OTHER CODES ARE ENFORCED, (1E. UMC, BOCA, ETC.) USE THE MOST STRINGENT COPE FOR DUCT CONSTRUCTION STANDARDS. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: 2' W.G., POSITIVE RETURN AND EXHAUST DUCTS: 2' W.G., NEGATIVE EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS; CLASS B - 3' W.G. RETURN AND EXHAUST DUCTS: CLASS C - 2' W.G- IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL 4. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCK SEAM CONSTRUCTION FOR ALL SIZES 14' DIAMETER AND LARGER. ROUND DUCTWORK SIZES 13' DIAMETER AND SMALLER MAY BE SNAP- LOCK CONSTRUCTION. ALL SNAP LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL P11114 SPOT WELDED AND BONDED CONSTRUCTION. DUCTWORK SHALL BE AS MANUFACTURED 13Y UNITED MCGILL, SEMCO, OR APPROVED EQUAL. 5, ROUND SPIRAL GALVANIZED STEEL DUCTWORK MAY BE USED IN PLACE OF RECTANGULAR DUCTWORK WHEN ABOVE CEILING CLEARANCES PERMIT AND EQUIVALENT FREE AREA IS MAINTAINED, WITH THE FOLLOWING EXCEPTION; ALL SUPPLY AND RETURN DUCTWORK WITHIN 15 FEET OF THE AIR HANDLER MUST BE RECTANGULAR AND INTERNALLY LINED. WHERE ROUND DUCT SUBSTITUTION WILL TAKE PLACE, SUBMIT A SKETCH AND CHART 5140WING EQUIVALENT ROUND CONVERSIONS OF RECTANGULAR DUCTWORK TO OWNER FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION. 6, AS A MINIMUM, CR055 BREAK ALL FLAT SURFACES OR REINFORCE W1TH A BEAD APPROXIMATELY 3/8" WIDE X 3/16' DEEP ON 12' CENTERS TO PREVENT VIBRATIONS, REGARDLESS OF DUCT GAUGE. 7. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS OVER 36' IN LENGI14. INSTALL FACTORY MANUFACTURED SINGLE THICKNESS TURNING VANES IN ALL OTHER ELBOWS 8. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. q. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM I- 1/2'X1 -I/2' X1/8' STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. 114E ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 10, ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASS- FIBER FABRIC REINFORCED TAPE. JOINTS ALSO SHALL HE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. 14. 1. 5. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. MGT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. PROVIDE ACr.E5S TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWOWC THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, It MUST BE APPROVED BY OWNER'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS 14ITI4 PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WOVEN WITHIN 3' -O OF DEVICE. ALL DUCTWORK SWAU_ BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. VAV BOX, DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. REFER TO DETAILS. F. MEDIUM PRESSU DUCT: WHERE DUCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, It WALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS FOR A PRESSURE RATING OF 6 INCHES WATER COLIAIN MINIMUM OR GREATER AS REQUIRED BY LANDLORD. 2. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE DUCT AND WITH THE LANDLORD'S CRITERIA. 3. CONNECTIONS TO THE LANDLORD'S MEDIUM PRESSURE DUCTWORK SHALL BE MADE WITH 'LO -LOSS' SADDLE TEE TAPS BY UNITED MCGILL CORP., OR As OTHERWISE REQUIRED BY THE LANDLORD. 4_ ALL OTHER ITEMS FROM METAL DUCTWORJK SPECIFICATION SECTION APPLY TO NIS SECTION, P11114 THE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK MUST BE WRAPPED INSULATION, NOT LINED. G. YERATION ISOLA DEVICES: I. VIBRATION ISOLATION DEVICES SHALL. BE FURNISHED AND INSTALLED WITH SUPPORTS BETWEEN VIBRATING EQUIPMENT AND THE STRUCTURE ( FANS, AIR HANDLERS, ETC.) BY THIS CONTRACTOR. 2, VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL SE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 3, EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID 'GROUNDING' THE ISOLATOR. 4. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. CONSULT MANUFACTURER FOR APPLICATION DATA. H. FLEXIBLE CONNECTIONS: 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPiMENT (FANS, AIR HANDLERS, ETC.) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE- COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. L FLEXIBLE AIR DUCT: 1. FLEXIBLE AIR DUCT SHALL BE I INSULATED CLASS I AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS ON DRAWING 114.3 FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS WITHOUT PRIOR APPROVAL FROM OWNER'S CONSTRUCTION MANAGER UNLESS NOTED OTHERWISE 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5' -0' IN LENGTH AT ANY ONE LOCATION. ND FLEXIBLE DUCTWORK UPSTREAM OF VAV BOX 4. J. SUPPLY AIR TAKEOFF FITTINGS: K. DAMPER$ 1. 3. FURNISH AND INSTALL CONICAL OR ' BELL - MOUTH" TAKEOFFS W/ DAMPERS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALL PER MANUFACTURER'S INSTRUCTIONS AND DETAILS ON SHEET M4.3 FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. 2. OPERATING HANDLES ON ALL DAMPERS SHALL BE TAGGED WITH A MINIMUM 18' LONG ORANGE MARKER TAPE. COLLARS MUST BE INSTALLED OVER EXTERNAL INSULATION TO ALLOW FREE MOVEMENT. SEE ADDITIONAL DETAILS ON MECHANICAL DETAIL DRAWING. NO VOLUME DAMPERS UPSTREAM OF VAV BOX. L 1. 2. FIRE DAMPERS SHAW. WAVE THE BLADES OUT ACCESS DOORS AS NECESSARY. 3. OWNER SHALL FURNISH DESIGNED FOR HORIZONTAL OR VERTI REQUIREMENTS. SLOT INSTALL PRIMARY FIRE DAMPERS WHERE INDICATED R AS REQUIRED. FIRE DAMP = UL LABELED AND MEET ALL CODE STREAM AND A • - LINK, TYPE B, AS MINIMUM. FURNISH AND INSTALL FURNISH AN NECESSARY FRAMING AND SLEEVE FOR DAMPER MOUNTING PER UL AND CODE BY CODES. DAMPERS SHALL BE SEE DETAIL ON M. DUCTWORK IISULATiON i. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA qOA. 2. DUCT SIXES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS, ALL SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK SHALL BE INTERNALLY INSULATED WITH I' TWIGK, I -1/2 LB. DENSITY LINER (C •0.28 @ 75•F). WHEN A COMPLETE DUCTED RETURN AIR SYSTEM Is INDICATED ON THE DRAWINGS, ONLY THE 15'-O' OF THE RETURN AIR DUCT CLOSEST TO THE AIR HANDLING UNIT IS TO BE INSULATED. LINER 15 TO HAVE A COATED SURFACE EXPOSED TO AiR STREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES TO BE COATED Wm4 ADHESIVE. 5. ALL ROUND DUCTWORK, OUTSIDE AIR DUCTWORK AND MEDIUM PRESSURE DUCTWORK SHALL BE EXTERNALLY INSULATED W1114 A MINIMUM OF 11!2' NICK, 1# DENSITY (R -5.6) DUCT WRAP 1041114 VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 50 WHEN TESTED IN ACCORDANCE WITH AST11 C 411, OR AS REQUIRED BY LOCAL CODES. SECTION 15500 CONTINUED NEXT COLUMN - r •I•: • - 1. 2. 3, VALVES: A, GATE VALVES, 2 -INCH AND SMALLER: SOLDER ENDS, INTEGRAL SEAT, UNDER PRESSURE BALL VALVES ARE 5. HYDRONIC PIPING: PIP -• A. USED AT B. ALL PIPING C. D. PRIOR TO CONNECTION TO FiELD REPRESENTATIVE, THA ACCORDANCE TO THE LAND LANDLORD'S SYSTEM. B. GATE VALVES, 2 -1/2 INCH AND LARGER- CLASS CAST IRON BODY, STEM, FLANGED ENDS, AND RE- PACKABLE UNDER SWING CHECK VALVES, 2 -INCH AND SMALLER: CLASS HORIZONTAL SWING, Y- PATTERN, RENEWABLE BRONZE D C. D. E. 4. PIPING SPECIALTIES: A, PRESSURE/TEMPERATURE TEST PLUGS ( PETE' LUG) - 1/4 INCH NPT PROBE, I/B INCH O.D. FITTING AND CAPS • BE BRASS WITH VALVE B. STRAINERS - 'Y' PATTERN STRAINERS, PSIG, CAST IRON BODY WITH P INCHES AND SMALLER, FLANGED FOR 2- INCHES AND LARGER. SCREEN OPENI FOR CHILLED OR CONDENSER WATER. IDE WITH BLOW DOWN VALVE WITH C. THERMOFLO INDICATOR - BELL +* FIT MODEL INSULATION: A. ALL HYDRONIC PIPING FOR ' PILLED WATER AND /OR HEATING WATER (NOT INCLUDING • • ; - WATER UNLESS SPECIFICALLY NOTED OTHERWISE), VALVES, Fl INGS, AND ACCESSORIES SHALL BE INSULATED CONTINUOUS, UP TO • • L CONNECTION. FOR PIPE SIZES UP TO 2 INCHES, INSULAT NTH 1 INCH THICK (K+023 @ 75'F) FIBERGLASS INSULATION WiTH ALL 5 4 JACKET AND VAPOR BARRIER. FOR PIPE SIZES 2- NCHES AND LARGER, INSULATE WITH 1 -1/2 INCH WICK (K •0.23 @ 75'F) I. P • INSULATION WIN ALL SERVICE .JACKET VAPOR BARRIER. B. C. D. C. 1514 AND INSTALL A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC • 15 RED. B ST FOR G PIPING FOR CHILLED WATER, CONDENSER WATER AND /OR HEATING WATER SHALL BE ASTM A -120, SGHEDU STEEL PIPE WITH PLAIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2 -1/2 INCH AND FE WITH THREADED JOINTS AND FITTINGS OR INSTALL TYPE 'K' ANNEALED TEMPERED COPPER TUBE W AND SMALLER PIPE. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS, ALL PIPING SHALL WITH ASTM, ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER 15 MOST STRINGENT. UNIONS PMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAT BE REQUIRED. ALL HYDRONIC PI AND EQUIPMENT CONNECTED TO THE HVAC PIPING SYSTEM SHALL BE CLEANED FLUSHED. REMOVE, CLEAN, AND REPLACE STRA SCREENS. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL LNG AND EQUIPMENT PRIOR TO CONNECTION TO THE S SYSTEM. CONTRACTOR SHALL NOT FILL TENANTS SYSTEM WI • TER FROM THE LANDLORD'S SYSTEM UNLESS SPECIE • Y INSTRUCTED TO DO SO FROM THE LANDLORD'S FIELD REPRES a • TIVE. SWING CHECK VALVE, 2 -1/2 INCH AND LARGER: CLASS 125 BRONZE DISC, FLANGED ENDS AND CAPABLE OF BEING COMBINATION BALANCING AND SHUTOFF VALVES: BELL GOSS BALANCE WHEEL MUST SE INCLUDED WITH 0 1 11 MAN - TACO INSULATION AT ALL INSULA NAT 50 LANDLORD'S 5T TEAM, CONTRACTOR SHALL OBTAIN WRITTEN TESTING, FLUSHING, AND PROPER FILLING OF THE REQUIREMENTS AND THAT THE TENANT'S SYSTEM IS ISO, BODY AND UNION BONNET ID BRONZE WEDGE DISC, RI AS AN EQUAL SLIEST CAST AND HANGERS FOR PIPING 2 1/2 INCHES AND LARGER SHALL SE HARD AND NON SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED CONFORM WITH WE REQUIREMENTS OF THE NFPA. PROVI " ZESTON OR EQUAL INSULATION FITTINGS FOR ALL TEES, ELLS OR SPECIALTY FITTINGS. SEE MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. ( NOT APPLICABLE EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE PSI. ERIN, INSTALL ILFOS JOINTS IN STRICT FLANGES MUST BE RMATION FROM THE LANDLORD'S S SYSTEM HAS BEEN COMPLETED IN TO BE CONNECTED TO THE ASTM B 62 CAST BRONZE P11114 THREADED OR STEM, SCREWED BONNET AND RE-PACKABLE UNDER BRONZE SEATS AND SOLID WEDGE DISC, RISING E BODY AND CAP CONFORMING TO ASTLI B 62 WITH VING THREADED OR SOLDERED ENDS, IRON BODY AND BOLTED CAP, HORIZONTAL SWING, RENEWABLE WHILE THE VALVE REMAINS IN THE LINE. CIRCUIT SETTER WITH LOCKING SET POINT. A CIRCUIT SETTER GRISWOLD ARE CONSIDERED AS EQUAL. NGS TO RECEIVE EITHER A TEMPERATURE OR PRESSURE OF NORDEL, RATED AT 400 PSIG, 0'F TO 200 TED STAINLESS STEEL SCREEN, THREADED FOR 2 SIZE AT 0.033 INCH FOR HEATING AND I/8 INCH END FITTING. NG OF NO HIGHER 6. = _ - NSTALLATION E ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. BRANCHES TO UNITS BELOW MAINS TO SE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWN WARD t UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD T UNITS. PITCH NOT LESS THAN P TO 10 FEET. •' J • a - - • ,a. PIPING: A. REFRIG = - • • - IPING SHALL BE TYPE 'L' HARD DRAWN COPPER TUBING (ASTM 588). TUBING SHALL BE NITROGEN B. ALL FITTINGS AND • ■ 5 SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI 316.22). ALL SWAI.L BE BRAZED P11714 • ER- P1405P1 4ORUS ALLOY AND ALL OTHER JOINTS SHALL BE C. INSTALLATION: A. SUCTION LINES SHALL HAVE ADEQUATE LI '- •PS AND /OR DOUBLE SUCTI ISERS TO MEET THE REQUIREMENTS OF FIELD CONDITIONS AND EQUIPMENT MANUFACTURER'S BRAZE ALL JOINTS WITH SILFOS -S STARTING AT TH • ••- UN N - D WORKING TOWARD THE OUTDOOR UNIT. THE SEALS ON THE OUTDOOR UNIT SHALL BE BROKEN LAST. A NITROG= = -. " SHALL BE USED DURING ALL SOLDERING AND ANY TIME THE SYSTEM IS OPEN. ALL OPEN LINES SHALL BE CAPPED " a■ BEFORE LEAVING THE SITE DURING CONSTRUCTION. PRESSURE TEST FOR LEAKS WITH AN INERT GAS AT 45 PS ' REDO LEAKING JOINTS AND RETEST UNTIL SYSTEM IS TIGHT. EVACUATE ENTIRE SYSTEM TO 200 MI ■ • .- M ERCURY. • - - E SYSTEM WITH 25 P51 GE R -22 AND A INERT GAS TO 245 PSI AND RETEST SYSTEM WITH HALIDE -I DETECTOR. ALL NG JOINTS MUST BE COMPLETELY RESEALED UNTIL NO LEAKS EXIST. TURN ON CRANK CASE 24 HOURS PRIOR TO ST -• COMPRESSOR TO BE SURE ALL REFRIGERANT LIQUID IS OUT OF THE COMPRESSOR. G. UPON COMPLETION OF TESTING, EFORE THE REFRIGERANT PIPING INSULATION I • - LIED, THE PIPING MUST BE INSPECTED BY A REPRESENTA OF THE LOCAL GOVERNING AUTHOWTY AS B. D. T PIPING: CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN THE INDOOR FAN UNITS AN FAN UNITS, IF APPLICABLE ALL ELBOWS ARE TO BE LONG INSULATE THE REFRIG INSULATION Wm4 ACCORDANCE WI APPLICABLE US TYPE ENDATIONS. SUCTION LINES AND CONDENSATE LINES ONLY WIT14 RUBATEX OR SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED OF STRY STANDARDS. DO NO INSULATE THE HOT GA5 (LIQUID) LINES OR ANY LY 2 COATS OF U.V. PROTECTANT /SEALER ON ALL INSULATION EXPOSED TO WEATHER. ( NOT APPUC CAPPED AND TO COPPER JOINTS WITH SILFOS -5 ALLOY. TROMa I INCH THICK PIPE THAN 50 IN GAS BYPASS LINES IF INSPECTION: A. OR MUST PREPARE AND SUBMIT A COMPLETE PIPING SCHEMATIC TO 114E LOCAL TRANE FIELD REPRESENTA ' FOR AL PRIOR TO BEGINNING INSTALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST CALL THE LOCAL TRANS INSPECTOR FOR FIELD INSPECTION OF WORK PERFORMED AT OWNERS EXPENSE. ALL ITEMS FOUND TO BE iNADEQUA FOR PROPER PERFORMANCE BY TRANE'S FIELD REPRESENTATIVE MUST BE CORRECTED AT NO ADDITIONAL CHARGES TO OWNER. SECTION 15500 CONTINUED NEXT COLUMN P. LABELS/PPE YARImtB: FURNISH AND INSTALL PIPE IDENTIFICATION MARKERS ON ALL PIPES INSTALLED UNDER THIS CONTRACT. MARKERS SHALL BE A MINIMUM OF i -1/2' X 8' AND IDENTIFIED IN ACCORDANCE P11114 THE BACKGROUND AND LETTER COLORS ISSUED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). MARKERS SHALL BE MANUFACTURED BY CHAMPION AMERICA INC. 800 - 521 -7000, OR EQUAL 2, PIPING SHALL BE IDENTIFIED AS FOLLOWS: CHILLED WATER RETURN, CHILLED WATER SUPPLY, CONDENSATE, HOT WATER RETURN, HOT WATER SUPPLY, CONDENSER WATER RETURN, CONDENSER WATER SUPPLY, REFRIGERANT LIQUID, REFRIGERANT SUCTION, AND DIRECTIONAL ARROWS. ALL IDENTIFICATIONS MUST BE VISIBLE AT EQUIPMENT. 1. R. TESTING. ADJUSTING. AND BALANCING: 1. TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR MO IS A CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (MEG) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEES) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY AND AS A MINIMUM SHALL INCLUDE THE INFORMATION AS SHOWN IN THE AIR BALANCE REVIEW CHECKLIST IN PARAGRAPH 7 BELOW. PAYMENT OF ALL COSTS FOR TESTING AND BALANCING SHALL BE INCLUDED IN THE BID. TESTING AND BALANCING CONTRACTOR TO BE LANDLORD APPROVED. 2. ALL CHILLED OR CONDENSER WATER SYSTEMS, AND ALL LANDLORD VAV SYSTEM REQUIRE A PRETEST TO OCCUR ONCE TAPS HAVE BEEN MADE TO THE LANDLORD'S SYSTEM AND WITHIN THE FIRST TWO WEEKS OF CONSTRUCTION. REFER TO DETAILS FOR PROCEDURE. 3. FINAL TESTING, ADJUSTING AND BALANCING REPORT MUST BE COMPLETE AND TURNED OVER TO OWNER'S CONSTRUCTION MANAGER 3 WEEK PRIOR TO MERCHANDISING DATE. 4. THE HVAC CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL DEVICES, VERIFY ALL OPERATING SEGUE7NCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO NE AIR BALANCE THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION, EXCEPT AS NOTED OTHERWISE. 14VAC CONTRACTOR SHALL ALSO INSTALL A NEW SET OF FILTERS EACH MONTH DURING CONSTRUCTION AND ONE DAY PRIOR TO MERCHANDISING. 5. BALANCING CONTRACTOR MUST CONTACT SYSTEMS INTEGRATION GROUP (SIG) AT (770) 427 -7443, 24 HOURS PRIOR TO AIR BALANCE FOR COORDINATION OF THE DIRECT DIGITAL CONTROL PANEL OPERATION DURING THE BALANCE. CAW.. SIG TO VERIFY PROCEDURES PRIOR TO BIDDING PROJECT AND INCLUDE ALL COSTS IN BID. 6. BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5X OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES, BELTS OR PULLEYS NEEDED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO OWNER. 7. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. 8. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO OMRNER'S CONSTRUCTION MANAGER FOR APPROVAL- THE GENERAL CONTRACTOR SHALL VERIFY THE COMPLETENESS OF 114! REPORTS PRIOR TO SUBMITTING TO OMER. SUBMIT ONE COPY OF FINAL APPROVED AIR BALANCE REPORT TO MALL GENERAL MANAGER. q. S. C THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED ON THESE DRAWINGS. ALL SYSTEMS UNABLE TO BE COMPLETELY BALANCED AT THE LIME OF ORIGINAL BALANCE MUST BE BALANCED IN FUTURE AT NO ADDITIONAL EXPENSE TO THE OWNER. THE BALANCING CONTRACTOR SMALL RECHECK ANY ITEMS THAT OWNER DEEMS NECESSARY AT NO ADDmONAL COST TO THE OWNER. TEM COIIMSSIONING: i- THE HVAC CONTRACT CONSTRUCTION COMPLETION DA BEEN SIGNED OFF ON CONTROL PANEL A 2. THIS CONTRACTOR SHALL INCLUDE AS A BASE, a -HOURS PER 14VAC UNIT SHOWN ON DRAWINGS. ADDITIONAL HOURS PROVIDED BY GINNER OR ANY OF OWNER'S VEIN NO ADDITIONAL HOURS SHOULD BE I MANAGER PRIOR TO TION 15500 BLE TO CONTACT SYSTEMS INTEGRATION GROUP (SIG) AT (770) ULE COMMISSIONING. THIS CONTRACTOR MUST HA -, i BE REIMEURSAB - - THE BID. THIS CONTRACTOR MUST REC mONAL HOURS. (NOT PR`1J %AL < II Veal C6 WEEKS PRIOR TO PANEL NUMBERS AND HAVE [ME PLUS AN ADDITIONAL 2 -HOURS OF COMMISSIONING LIME LE- SHOOTING OR REPLACING FAULTY EQUIPMENT AND /OR OWNER'S VENDORS AS NECESSARY AND AL FROM OWNER'S CONSTRUCTION CODE COMPLIANCE 5 U LDING RECEIVED CITY OF TUKVVILq R V 28 il..,, Pct EEvei I (,rtl` i ER 0 z 0. 3 / r W I- W 0 _0 To 5 cc cn z 0 1- u_ 0 w a U) J z 0 W 0 IJ I- ce W 0 LO r r a C W Ce Z LIJa CC C = W co 0z O. l j W ♦ W�,L,O� / � J 0 I- V) O W W t� (0 co E Z V) A ABFC50017 SHEET M CONCEPT 5 LANDLORD DATE: 9/14/07 L.L.- LANDLORD DIRECTIVE MASTERS 7-27-2007 T.D.- TENANT DIRECTIVE B.D.- BUILDING DEPT. BLDNG DEPT TAP INTO TI-IE NEAREST AVAILABLE COLD WATER SOURCE (COLD WATER INPUT TO WATER HEATER, DRINKING FOUNTAIN, BATHROOM, ETC.) USING 1/2" COPPER LINE OR TUBING. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A 1/2" THREADED BALL TYPE SHUT —OFF VALVE MOUNTED TO THE WALL IN AN EASILY ACCESSIBLE LOCATION. 72 INCHES OF STAINLESS STEEL BRAIDED TUBING AND THE HARDWARE TO CONNECT TO A 3/8" BALL VALVE WILL BE INCLUDED WITH THE MACHINE. ALL CANADIAN AND CERTAIN U.S. LOCATIONS REQUIRE THE USE OF A BACKFLOW VALVE. CHECK YOUR LOCAL PLUMBING CODE. THE WATER LINE WILL NEED TO BE BLED AND FREE OF DE8RI5 BEFORE IT IS CONNECTED TO THE MACHINE, AFTER CONNECTING CLEAN INTERNAL STRAINER AND CYCLE WATER UNTIL STRAINER REMAINS CLEAR. THE WATER PRESSURE MUST NOT EXCEED 100 PSI. IF TI—IE WATER PRESSURE I5 GREATER THAN 100 PSI THEN A 50 PSI REGULATOR WILL NEED TO BE INSTALLED. WALL V2" BACKFLOW PREVENTER VENT 3/8" BRAIDED COPPER TUBING BY MANUFACTURER HANGERS (MUST BE AT 6" BEFORE DROP) ----- 1/2" TYPE "L" WATER SUPPLY, CLAMP TO WALL AT TOP, MIDPOINT AND BOTTOM. PROVIDE A 3/8" BALL VALVE 1/2" TYPE "L" VENT PIPE DN TO I" AFF ADJACENT TO 1/2" WATER SUPPLY. TURN OUT TOWARD FLOOR DRAIN WATTS SERIES "D9" ASSE1012 STANDARD DOUBLE CHECK BACKFLOW PREVENTER �— PROVIDE 6' OF 3/8" BRAIDED COPPER TUBING AND CONNECT TO STEAMER SY MANUFACTURER. DREAM — STEAMER BY OWNER WT. 350# — 3 . . SCTION VIEW DECK ABOVE JOIST/BEAM IN WALL ACCESS PANEL BY G.G. CEILING FINISHED FLOOR SANITARY STACK DIAGRAM SCALE : NONE STRAINER, FLUSH WITH FLOOR NOTE: DRAIN SUPPORT STRAP yi 11 ADJUSTABLE DRAIN HEAD A. FLOOR DRAIN COVER FLUSH WITH TILE OR FLUSH WITH CONCRETE FLOOR IN AREA WITH NO TILE. 5. CONTRACTOR TO SNAKE DRAINS 2 DAYS PRIOR TO OPENING. FLOOR DRAIN DETAIL DRAIN BODY INSIDE CAULK PLUMBING FIXTURES WC WATER CLOSET: AMERICAN STANDARD "CADET' MODEL 2377.100, FLOOR MOUNTED TANK TYPE PRESSURE ASSISTED WATER CLOSET, VITREOUS CHINA. ELONGATED BOWL. CLOSED COUPLED FLUSHMETER TANK. 1.6 GALLONS PER FLUSH. WHITE COLOR. 17" RIM HEIGHT WITH WHITE RISE— AND —SHINE ELONGATED OPEN — MONT _ SAT AND COVER #5325.024— FLUB HAN E TO-5E O1LOPEPSDE WATE CL ET. LAV LAVATORY: AMERICAN STANDARD MOUNTED AT WHEELCHAIR HEIGHT MODEL 9141.011. WALL MOUNTED 18.5" x 20" VITREOUS CHINA. 4 CENTERS. WHITE COLOR. PROVIDE JOSAM 17105 -67 SERIES CARRIER, CHICAGO #895 -317CP GOOSENECK FAUCET WITH 4" CENTERS, BLADE HANDLES AND CHICAGO VANDAL RESISTANT ECONO —FLO WATER CONSERVING AERATOR #E2805 -5. MCGUIRE #158 —WC SUPPLY STOP, MCGUIRE #155 —WC STRAINER WITH OFFSET TRAP. M3 MOP BASIN: FIAT MODEL M55-2424. 24" x 24" X 10 ", MOLDED STONE SERVIGEPTOR, VINYL BUMPERGUARD. PROVIDE #832.AA 36" LONG, 3/4" HOSE AND BRACKET WITH WALL HOOK AND CHICAGO #897 FAUCET WITH INTEGRAL VACUUM BREAKER. NH ELECTRIC WATER HEATER: A.O. SMITH MODEL ELJF -6, 6 GALLON ELECTRIC WATER HEATER, 1500 WATT ELEMENT. GLASS LINED, FOAM INSULATION. BAKED ENAMEL FINISH. 120 VOLT 1 PHASE. FQ FLOOR DRAIN: JOSAM #30003- 5A -50, 3" FLOOR DRAIN WITH NICKEL BRONZE FINISH AND TRAP PRIMER INLET CONNECTION. PROVIDE DEEP SEAL TRAP. TP TRAP PRIMER: PRECISION PLUMBING PRODUCTS MODEL P2 -500 TRAP PRIMER VALVE, WITH DU -2 DISTRIBUTION UNIT AND SS -8 SUPPLY TUBE FOR USE WITH UP TO 2 FLOOR DRAINS. EWC ELECTRIC WATER COOLER: OASIS MODEL PBACL, WALL MOUNTED HI —LOW HANDICAPPED ELECTRIC WATER COOLER. STAINLESS STEEL CONSTRUCTION. 4 —TIMED TOUCH PADS. 5.0 GPH @ 50 DEGREES F. 1/4 HP, 4.6 AMPS, 115 VOLT /1 PHASE. PROVIDE WITH TRAP AND A BALL VALVE ON SUPPLY LINE. MOUNT WITH BUBBLER AT 36' A.F.F. WCO WALL CLEAN OUT: CAST IRON CLEAN OUT TEE WITH BRONZE TI— TREADED, WATER AND GAS TIGHT CLEAN OUT PLUG. JOSAM #58604 —PLG4, WALL ACCESS PANEL 5- 1/2 "4 SMOOTH NICKEL BRONZE, SET FLUSH TO FINISH WALL PLANE. FURNISHED WITH SECURING LUGS. FCO FLOOR CLEAN OUT JOSAM #57004 —SD -2. CAST IRON BODY WITH GAS AND WATER TIGHT ABS TAPERED THREAD PLUG AND ROUND SCORIATED TOP ADJUSTABLE TO FINISH FLOOR. WATER RISER DIAGRAM WATER HEATER MOUNTING 30 AMP. INDIVIDUAL BRANCI -I CIRCUIT — DRAIN (DO NOT CONNECT) BACKFLOW VALVE PER LOCAL PLUMBING CODE BY CONTRACTOR 30 AMP. 3 —POLE 4 —WIRE GROUNDING RECEPTACLE WITH NEUTRAL (NEMA LI5 -30). SEE ELECTRICAL SHEETS FOR FURTHER INFORMATION. — WATER SHUTOFF VALVE MUST BE SECURELY MOUNTED IN AN EASILY ACCESSIBLE LOCATION WITHIN FIVE FEET OF THE LEFT SIDE OF TI—IE MACHINE BALL TYPE 5HUTOFF VALVE REDUCER � — 3/8" COILED COPPER TUBING APPROXIMATELY SIX FEET BY MANUFACTURER. �I ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. ® RUN 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE IN AN ACCESSIBLE LOCATION. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. ® PROVIDE SHUT —OFF VALVE, ETC. ALL IN ACCORDANCE WITH LANDLORD'S CRITERIA. INSTAL1 A PRESSURE REDUCING VALVE WHEN INCOMING WATER PRESSURE IS GREATER THAN 60 PSI. ALL INSTALLATIONS AND CONNECTIONS SHALL BE IN ACCORDANCE WITH TI—IE APPLICABLE GODES, LOCAL AUTHORITY'S REQUIREMENTS AND LANDLORD'S CRITERIA. _ w SHEET ::s PARTIAL PLUMBING PLAN SUPPLY & DRAINAGE FIXTURE UNITS DOMESTIC COLD WATER FU'S (2) BATHROOM GROUP'S (PUBLIC) (1) MOP BASIN (1) EWC (I) DREAMSTEAMER FU'S GPM 7.20 3.00 0.25 0.25 10.70 15.0 DOMESTIC SANITARY FU'S FU'S (2) BATHROOM GROUP'S (PUBLIC) 10.0 (I) MOP BASIN 2.0 (1) EWC 0 5 12.5 SANITARY PIPE SIZE = 4" NOTE: INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS. VACUUM BREAKER BY P.C. ---- -- EXPANSION TANK AMTROL 5T-5— 2= CW 3/4 E/ GATBALL VALVE BY P.C. (TYP.) CHECK VALVE DRAIN VALVE BY P.C. PLYWOOD PLATFORM SY GENERAL CONTRACTOR — UNION BY P.G. (TYP.) WATER HEATER SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. 2' WIDE, 20 GA. SHEET METAL BAND, SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED SY CODE. (BY P.G.) GALV. DRIP PAN BY P.C. CODED NOTES: ® AL WAT R LI S, VEST LIN S 501 LW, SPMI LIN S, ETG S SHAL B O E FSET BELOW PLATFORM AND CONCEALED IN WALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETC. THROUGH STORAGE SPACE ABOVE PLATFORM OR ABOVE ELECTRICAL EQUIPMENT. 53 CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE. FIELD VERIFY EXACT LOCATION AND DIRECTION OF FLOW OF LANDLORD'S MAIN PRIOR TO BID. INSTALL CLEAN OUT, COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR FINISH WITH CONSTRUCTION MANAGER. CONNECT NEW VENT FROM TENANT'S PLUMBING FIXTURES INTO EXISTING VENT LINE. REFER TO STACK DIAGRAM FOR MORE INFORMATION. FIELD VERIFY EXACT LOCATION PRIOR TO BID. ® CONNECT NEW COW WATER LINE INTO LANDLORD'S EXISTING COLD WATER TAP. NOTIFY CONSTRUCTION MANAGER IF TAP SIZE 15 SMALLER THAN SHOWN ON RISER DIAGRAM. FIELD VERIFY EXACT LOCATION OF TAP. ® FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND I-10T WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM_ WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE. PLUMBING SYMBOL LEGEND DETAIL DISCRIPTION DETAIL DISCRIPTION SAN SANITARY WASTE FCO�_ FLOOR CLEANOUT PIPING — — — — — V — — — — — VENT PIPING VACS IFO WALL CLEANOUT -- — — CW -- — — COLD WATER PIPING ❑4 SHUT —OFF VALVE — — — --NW — — — HOT WATER PIPING 0 WATER METER G GAS PIPING �M— GAS SHUT —OFF AND UNION CONNECTION TO EXISTING RECEIVED CITY OF TUKWILA .J.v 2 8 cL r Pi=4 ao 1 GEN i ER BFC50017 4 ir tze ,:e el ' ' ' / . CONCEPT 5 . , ., ,'.., s ,..„....4 - ....,/ - _ ______ _____ _ _ .. ,..‹.‘,. A■ , ,,, IV ,,,,_) e ..._ __ -----L---,--- t , \ , ,., , g. ! ., '-. .. . . - ,-- ----s ML ,...._ , --,-- t \ ,, / \ / \ P/ ,.. ' , ..., T.,. . , , -1 .- , ?_4(i 4 — --. , , ---- "--' - V , _ , / r=r . tfr- ...., # T . ‘, A* rr sex& `---- 4 I / , 0 l'. ■ jr. I I / '''' / '''' 4:■ I, -.6` A _ ._.. =J i ((' ' ''' I t 4.,... 4 --- .. .... 44.4.4 44... -4 \ '' .........4 , \ \ .// 4 \ cs, \ '/4/ ' '0 / .44.4 / Vti le F4‘,‘,.. . ''' r/ ,..„ " , • 1 / il ' 4 . . ?fr 4'''.'';'4'.' 4 .'' 7 ":; N J' \ ,:',. --. _ ., ...„:„.:, , , i „„ ,..4,y,4" • --,- <..,', i • _ _ j ._. _ , . ___ . ',......1 s e , , ,... (7,-,) t„/ .__. _ / _ _ _ ,.,.„ . -, 4,-/ ' / /7 - ____ le . : , . / .>. " (,----=‘, '--:.:, K,' _ - -- . <4.r. ; , , • • .-, . s • N, \ . / .,). , + ,,,, n '" , \ . . 4 ■ i 4.;-Er , . _ _ • , Pi&e.# firer l'eN„ 0 ,,, . .-._..j , ..;/ , '0 .. - I. - .,....---.., 0 "1"1'20,4 e .. , WM — _ 1 (' , 4 - -ex.a,s-kv 'A , -„ , . , r e , ,, ,.., G , O ''' /if . • . , , - - A, 47 Ati-• - es' -eY, '- -- 1 ' z ' ''''' „, , (-;'" .. • • ,,,,---',', , /:-----,,, :,-_,.•,‘ '‘... .7' __,..., , i - p ''''''"'w -.7- -- - --.7",-.1.=..-17.---7.2.--....- 0 _ . _ _ . . ---- _ . .., 4" - 4. 0 ,. , i , n' : 7 . , ' ;., t / .:"' ' , _-___ _L_ ; ,• „ ,...„, . _... .. 1 Z2iZ , "i" ."..'s \ of 1 4/ ,,e xrir' _ ■ k,-,../ , .1 , f, ''. , :•,-/,' Alorezelizeorett . Nw, ..-.‘ -,,,.. ,, - . — - , _.----: . , --.... 1 1 REVISION DIRECTIVE KEIf1 B.D.- BUILDING DEPT. T.D.- TENANT DIRECTIVE G.C.- GENERAL CONTRACTOR DIRECTIVE L.L.- LANDLORD DIRECTIVE 9 - , • . _ ', P ,\,..., ,....._ ......_ ■ ......-=.... .... 1 • • , ___ ..„,----, ' , f ■ -- , „,,,, , ,. , .._ , ;■-• ,, ,,.. • , • ---- 4, , .4' /2 W. , - ■tei .13 4 'a + i •••'-' b. --, \_... '''' e , / / . - / • ,,,., ,... ,, _ / ..t-e, ,,..77'^- • ,.. ‘ V ei `.1:----::---Z-' " -eV / , - ..- •,,,.- -'^'-'7 ../ A ,t _ / •,.., .-e 0 _ , ',=,-.L.,' „___ ' , _ , , _ . A' 7,.. REVISIONS: I Ai 11 -21 -07 - . . „. ... (.4 - - • • ,_, - _ , , -- . 74 ,; ___________ n _ i;rs' ' - .... . - - . .., ... 77 , / . /. 0 Y'''k .,‘ . ,_ . ___ . _ _ ___ ,-, . , - - • . _ • (.• , r:11 :1 ..---, _ , / I , , r , g'''' /-• , _ _ _ ___ / ,., / :, i' - 9L . ISSUE DATE: PERMIT DATE: 9/75/07I I LANDLORD DATE: 9/74/071 BID DATE: 9h6/07I MASTERS 7 -27 -2007 F 9 • 4 1r / 1 4 , ,--,. ,- -11 t// — . — _ s . . ' . .4 • -T, -, „ • .:.; . / '. __ e 41111 k , 1 _ ,-- '''s ' i 0, . .;.* - - ..... ....k , 6iiiiiii I — -, L- 4,,Z\ ,...., 4 ...6. . 4 _ ,./ 4 -- — %, z 1 77.-- -, ,.., 2 : .._ ..., _ , - ,elY -..., _.--2 ' iiVi- LAN CONCEPT 5 115 WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY SEATTLE, WA 98188 DRAWN: LM CHK:.BB / ;;?.1,- -- 0 , , 7 . .., , ,.., '1 , , /,.,..- ' ).,., , .,,,,, , e 0 ,. • , ... . ,,t , A. z t ,v0v.. i* *A* . Atmr•vo. -iims-,A1 :,,„ . - .. . ,, ,_ . . .4..... .• , •,..., =,,, ..„,, I f_ . , 1 i • , .,,,, i -7 E SPRINKLER HEAD PLAN NED. dam :INaIJ DSGNR: MB I SCALE:A5 NOTED 1/4" = T-0" w SPRINKLER GENERAL NOTES: SPRINKLER HEAD LEGEND . _ 4- van P st. f; 'ctAz' ' f / /..' ' 2 l'' i \ ''',,\ A. DRAWING FP1.1 'SPRINKLER HEAD PLAN' REPRESENTS DESIGN INTENT FOR SPRINKLER 1-IEAD F. FIRE PROTECTION PLANS (SPRINKLER DRAWINGS) MUST BE ENGINEERED AND WET SEALED BY A LANDLORD LAYOUTS. FIRE SUPPRESSION SYSTEM DRAWINGS TO BE SUBMITTED BY CONTRACTOR. APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL JURISDICTION. EXACT SPRINKLER I-IEAD QUANTITY, PLACEMENT, AND HEAD TYPE TO BE DETERMINED BY FIRE SUPPRESSION SYSTEM DESIGNER. G. PROVIDE 0.5. $ Y. VALVE, FLOW SWITCH AND TAMPER SWITCH AT CONNECTION(S) TO LANDLORD'S SPRINKLER MAIN. B. SPRINKLER I-IEAD5 SHALL BE SUPPLIED AND INSTALLED BOTH ABOVE AND BELOW THE PORCI-1 ROOF ASSEMBLY (IF REQUIRED) 1-1. W1-1ENEVER POSSIBLE ALIGN SPRINKLER HEADS WIT1-1 LIGHT FIXTURES, AIR DEVICES AND TO CENTER OF TILE. TI-IE PATTERN IN EACI4 ROOM SHALL BE CONSIDERED INDEPENDENT OF OTHER ROOMS. COORDINATE ALL C. A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR SI-IALL BE EMPLOYED ur THE LAYOUTS WITH OWNER'S CONSTRUCTION MANAGER MECHANICAL CONTRACTOR TO PERFORM ALL SPRINKLER SYSTEM MODIFICATIONS. J. REFER TO ARCI-IITECTURAL REFLECTED CEILING PLAN FOR CEILING 1-1EIGHT5 AND GENERAL COORDINATION. D. FIRE SPRINKLER SYSTEM TO PROVIDE 100% SPRINKLER COVERAGE BELOW CEILINGS IN ALL AREAS PER THE STATE AND LOCAL FIRE MARSHALL. K. ROUTE ALL PIPING AROUND ELECTRICAL PANELS. COORDINATE WITH ELECTRICAL CONTRACTOR. - E. CONTRACTOR TO PROVIDE SHOP DRAWINGS AND CALCULATIONS FOR BUILDING DEPARTMENT P ....‘• r. - 0 UPRIGHT SPRINKLER HEAD • CONCEALED SPRINKLER I-IEAD WITH BLACK FINISH (INSTALLED IN ALL SALES AREA CEILINGS WITH DARK FINISHES) IEAD WITH WHITE FINIS ED CONCEALED SPRINKLER I- H (INSTALLED IN ALL SALES AREA CEILINGS WIT-1 LIGHT FINISHES) e RECESSED SPRINKLER HEAD (INSTALLED IN NON-SALES CEILING) e RECESSED SPRINKLER I-IEAD 'INSTALLED IN GYP. BD. CEII-ING BELOW) H 0 PENDANT SPRINKLER EAD (NOT USED THIS STORE) CI FIRE E<TINGUISHER RECEIVED CITY OF TUKWILA L. , 2 8 PahiVill (JEN i ER "19,1 m i tltrz -, A ltib /,.,. ABFC50017 SHEET . APPROVAL PRIOR TO INSTALLATION OF SPRINKLER SYSTEM. FIRE SPRINKLER SYSTEM TO MEET REQUIREMENTS OF LANDLORD, NFF'A 13 ,TI-IE STATE AND LOCAL FIRE MARSI-IALL OR M. SPRINKLER 1-1E.AD5 LOCATED AT TI-IE SERVICE CORRIDOR ALCOVE AND 8E1-IIND LEASELINE AT STOREFRONT TO WHICHEVER IS MORE STRINGENT. REFER TO SPECIFICATION SECTION 15300 ON SHEET M4.1 FOR FURTHER INFORMATION. BE SUPPLIED AND INSTALLED BY SPRINKLER CONTRACTOR WITI-1 TIE-IN TO 'CONCEPT 5' SPRINKLER L.INE , A FPl• 1 1 _ 1 REVISION DIRECTIVE KEY1 BD.- BUILDING DEPT. T.D.- TENANT DIRECTIVE G.C.- GENERAL CONTRACTOR DIRECTIVE L.L.- LANDLORD DIRECTIVE ,• f W •�r i '" '� « d i 3 i ✓ i 5 " " '.' ,� < ^ `� ; : 'M.«..wb.�,wr::.,.. h . �, ,.• S :$k'P " RaaS y1 : w..._. S i xiv $ F 9 $ 3 S r ^ � ^' ; f ��'M... f € J r '. i' i �°' f.i SQ ,.. t _ f y ✓r. ., f • € mms+am+x y f : 9 {if \ icy' � �+ti9� ^.l 5&' t ? . � r acx. •A 4 s�...�.:""�,"".",..' 71. .� : xum. ; - ne.= ..- �-�...w..�w.r,w .wrx...«.ae ..�.mM. :SNOISIAN I Ati 11-21-071 3 S i x • t 4 -t.v`'� �, �; '' � z �4l / 4 a r � a >> F' 'w ".p .r € , ..,.�_r.._.... , ._ ... _....�_ ±g `:" ,:'V'f • 3 W �f „`w'""�"" .� ^Y •fe%h.^,....._._..,...".^-«, {. l/''�, `i\,� "n ,.n„s 4k A5:,. � / „r'Y- ,^"TA`. //'/xylyY�*'.t e✓d}',6t ti 3 ... � .! � 4 " • 3 i{ _....�. ___ _ _� _ .. _._. _.. _. ,.. �� ^. ". ....._. '�e3s;z �8'4:C' .i e....^se ?.fig .zc:: a me.,.saxx.r,.. a.. 7vn n,. iwwan• wetudt xe .Mr .x,s,,..„.+. r w»..... ar... m.. wawwcew �a” ? ..✓ S ✓ v'"L.. P .. .. ... ... M .� '�'•4 i fb• x x. ✓.: �wSt � ..�...¢�:!xv�,Grs,.�M.! /�;,�.�' 0 Ly �s ffi3 : '� wy . � /�$iE.a € ^ y; `"L:4" •.L , .i'.+ F. f wyy.w..w:�tw .% 'G _ f // 3•yi{ e 1 � Yom.. � :. ". � .�_ �" l..»..,.,..P..: y � 9 „ 4 ,,.. J �:t: '. " ., ..,°aa J > ax.. ,,"„� ,, } {, .... tir . t i ... �...fa.... i p f 4 S� J ! F �� ��r.! �•p'^ .S.: : xd� fi g, kd -wui a f -+✓ �..� ^,..�... ..,..... ,..�... ".,. .... . ° ..M�..�a. �>,�i,.•c<g,�'`g<ms�xg` I ISSUE DATE: I PERMIT DATE: 9/15/071 I LANDLORD DATE: 9/14/071 I BID DATE: 9/15/071 MASTERS 7-27-2007 I '677? ,y . '.y"' ' �e..' I ---- 1 T ` € :, ........, Wu.' ..',.wx.�.xt'...' .. � I` 9�. C . .:G/�� /yL. .:� - ^ 4'al , "3 h� - .':l? .a� > % ,,�'. %' 'ue. ,d ddL'2e2r w.....r.^;m ^. .' ; �l�a'� _ "� P ' �n / .'� F� r.� E 'J €; s :• ._ �.S%.:w .....'r .:....::^_.._ „_i 1 f k,. \ 4,+�,f • / ; i Yom• `. ,G:. ....... t 3 5. ^.'. .✓ i. � .... ! � «�Y... °".'�`•'' �•^.�- n.'?�^ .. ''L3k &"..u�,:a( ` i F € ✓ �¢ � 8 � ! 3 3 °`a..f • , "T.^ff 0 f” ^1 'R • , ._.. ' i R' .. --.. 8 .'�: -Y's% _.ma € !✓•, Y:s ' rv"y gym, .mod x.:°..tw'x, a :'�:. a ¢ asa;s '""'. • t �s , C;• 2 " m m s `93.s ' ✓ 3 LAN CONCEPT 5 115 WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY SEATTLE, WA 98188 gr :NHO , i� ✓ ' • Y ! ?rfi ' , . .^ 'a �a" f ^y µ S ii ` ... �$ 11 F a �' ." ✓w�' '�.�F'.: .1.WF !J T�:�. �3 g ffi�:t� . a : DRAWN:Lm / . , i ! { ? , $ i �+`� §' €l' . r ✓ ±ux xa .es, f t S F t t tr 3y ✓#µ. F € t 4saF � v" `e. �' . C . F• Y^w �€ '•. 3�` � � �, € ���•: i p' ' / \ .ry n� "av ' .. _ r 9' 4¢ ,y..5) \ iar S? J :b" �. � � y,. y{ R �€, r�t+�'� R' k.. �,' s ter" ,, dam :P181J ✓` e %if• bf"' ,........._..�i.R - .:.`�. %"ns " agi,^5.. " t a« 3 p naau�a....«.m.... =,n..d« sae.. uvs...a..�..,,..w.+,•......wxra :lnw.xrrxmux ...nao-..«,, . € {f,�'. j - , d i tr�c r �� ✓ i d� s �,'. � a�'.€ :, ! €/" _f� � � f t:. s f''t '$CCf''�'�"��..J.. �w..F`# °., .e'. X23, Y ��, ' ^ ttA s € ; '£. „_... ...-.. ...�.,gY��+:,•rr�<� Ste.- '� ..,.._...._ ..................` .^.. } �$ a'"'£ �l .es k., � �.c 1 ✓ lb ±R: MB _ ` Gy °°YY77 t:'£ i ,1.. � r I .y°i ^^*. Y dr> ✓ €S'�. ` faz.., w,µ«. amr�"�...«.. ..e..�x �..f. -. , -.w ww.«w ,.-.. y�...q�M...�v:.. mm / �i, » y.. s 3. }"�s`•: `r'�� rr. / �' . •[ 1 i � ,, •d;r' � �• F t • � �`7 • '5e ..xa "s I SCALE:AS NOTED i ssP':�.r ,,,, .€`i. „ S,.,y... .: pa:: • n... ,.x }. s Jv >; .•3.. p .,. »�-, �.�...r i��' �s , „S'.�. �' >,,:�• �' °"` � '�. +� L .''✓ , �''� J. ' /...J ce / f / >• .e^ • �x �l. J Y. . � r f ..' . �' . J I , wu u e xre�.e....rr.. ✓ ....,,s.a�: a�.�klriF..l¢....�.e r:ar.4 ,yu.C� �...x...e , �C.. �w... I . 11 s..- rv��.x. ,.. s �'SA; » c...,,. ,...... 'x•'°"°� t �.e.�...• .. a - „- ..°a✓s ux.*�+� 0 • SPRINKLER HEAD PLAP N C S 'li , l��. d��'s s r� I .f/k. � ��.d d 'L.� �� f ^. / .F` -�� e �xYdx ". 2'*•^:3 �e�#="wL�" b. T . aces x <,...• � v � '.�_, _ .�... sx..,. .. t. ... , d >5 - . , . <:x¢Wp' p�� �Y.;. �'; ..c�: u::i;Fs: � y;C Y5k i.ai ,.. .•K$.,.. ,ic , V Y i'..¢f« '#y.','•x. .a,. 4G u¢f;xf , fus, > :n : •. .ntn ,. ...a, wrw.xL. &.. ��. �'.. :�.r�.a:&S'C:^^!,k�w. �F .. � � � •'j W SPRINKLER GENERAL NOTES: SPRINKLER HEAD LEGEND � � A. DRAWING FP1.1 'SPRINKLER INEAD PLAN' REPRESENTS DESIGN INTENT FOR SPRINKLER HEAD F. FIRE PROTECTION PLANS (SPRINKLER DRAWINGS) MUST 81= ENGINEERED AND WET SEALED BY A LANDLORD LAYOUTS. FIRE SUPPRESSION SYSTEM DRAWINGS TO BE SUBMITTED BY CONTRACTOR. APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN TIME LOCAL JURISDICTION. EXACT SPRINKLER HEAD QUANTITY, PLACEMENT, AND I-IEAD TYPE TO BE DETERMINED BY FIRE SUPPRESSION SYSTEM DESIGNER. G. PROVIDE 0.5. * Y. VALVE, FLOW SWITCH AND TAMPER SWITCH AT CONNECTIONS) TO LANDLORD'S SPRINKLER MAIN. PORCH ROOF ASSEMBLY (IF REQUIRED) H. WHENEVER POSSIBLE ALIGN SPRINKLER HEADS WITH LIGHT FIXTURES, AIR DEVICES AND TO CENTER OF TILE. EACH ROOM SHALL BE CONSIDERED INDEPENDENT OF OTHER ROOMS. COORDINATE ALL THE PATTERN IN E B. SPRINKLER HEADS SHALL BE SUPPLIED AND INSTALLED BOTH ABOVE AND BELOW THE D. C. A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR SHALL BE EMPLOYED BY THE LAYOUTS WITH OWNER'S CONSTRUCTION MANAGER MECHANICAL CONTRACTOR TO PERFORM ALL SPRINKLER SYSTEM MODIFICATIONS. J. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND GENERAL COORDINATION. D. FIRE SPRINKLER SYSTEM TO PROVIDE 100% SPRINKLER COVERAGE BELOW CEILINGS IN ALL AREAS PER THE STATE AND LOCAL FIRE MARSHALL. K. ROUTE ALL PIPING AROUND ELECTRICAL PANELS. COORDINATE WITH ELECTRICAL CONTRACTOR. E. CONTRACTOR TO PROVIDE SHOP DRAWINGS AND CALCULATIONS FOR BUILDING DEPARTMENT L. PRO ._ DE 5--INK „- H •!5 GUa'DS ► ALL ! AT! 5 5 E 0 Dr AGE,,.. •• APPROVAL PRIOR TO INSTALLATION OF SPRINKLER SYSTEM. FIRE SPRINKLER SYSTEM TO E SERVICE CORRIDOR ALCOVE AND BEHIND LEASELINE AT STOREFRONT TO MEET REQUIREMENTS OF LANDLORD, NFPA 13 ,TI-IE STATE AND LOCAL FIRE MARSHALL OR M. SPRINKLER HEADS LOCATED AT TI-IE WHICHEVER IS MORE STRINGENT. REFER TO SPECIFICATION SECTION 15300 ON SHEET M`4.1 BE SUPPLIED AND INSTALLED BY SPRINKLER CONTRACTOR WITH TIE —IN TO 'CONCEPT 5' SPRINKLER LINE � *' FOR FURTHER INFORMATION. 0 UPRIGHT SPRINKI.l±R I -11±AD • CONCEALED SPRINKLER HEAD WITH BLACK FINISH (INSTALLED IN ALL SALES AREA CEILINGS WITI -I DARK FINISHES) CONCEALED SPRINKLER HEAD WITH WHITE FINISH (INSTALLED IN ALL SALES AREA CEILINGS WITH LIGHT FINISHES C ) a RECESSED SPRINKLER HEAD (INSTALLED IN N —SALES CEILING) RECESSED SPRINKLER HEA (INSTALLED IN GYP. SD. CEI LING BELOW) PENDANT SPRINKLER HEAD (NOT USED THIS STORE) F8 FIRE EXTINGUISHER -,,,c 7; 49 '- `c� f y` RECEIVED --z„, CITY O TU IWILA v r Z Ci. �� yH PG�el � �+i I`�! �� s ABFC50017 lc AT R RO V AN D SHEET vi l R LQ, RED FP1•2