Loading...
HomeMy WebLinkAboutPermit M07-212 - VERIZON WIRELESSVERIZON WIRELESS 17100 SOUTHCENTR PY STE 116 M07 -212 Parcel No.: 2623049081 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 17100 SOUTBCENTER PY TUKW Contact Person: Name: BRENT ADKISSON Address: 2020 S 320 ST #C -90 , FEDERAL WAY WA Contractor: Name: D15 MECHANICAL Address: 2020 S 320 ST #C -90 , FEDERAL WAY WA Contractor License No: D 15MEM *930BT DESCRIPTION OF WORK: SHELL WORK ONLY: INSTALL (2) NEW HVAC ROOFTOP UNITS WITH DUCT DROPS INTO SPACE FOR FUTURE DISTRIBUTION BY TENANT. INSTALL (2) BOTH EXHAUST FANS. Value of Mechanical: $10,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 City-4f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT VERIZON WIRELESS 17100 SOUTHCENTER PY, STE 116 , TUKVVILA WA WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 2 0 0 2 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360 888 -5433 Phone: 360 888 -5433 Expiration Date: 01/30/2009 M07 -212 10/10/2007 04/07/2008 Fees Collected: $269.58 International Mechanical Code Edition: 2006 Boiler Compressor: 0 - 3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 2 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -212 Printed: 10 -10 -2007 Permit Center Authorized Signature: Signature: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pey- ce of work. I am authorized to sign and obtain this mechanical permit. Permit Number: MO7 -212 Issue Date: 10/10/2007 Permit Expires On: 04/07/2008 Date: { 0 IP' 0 1' Date: �G ' -0 7 Print Name: / 1A T This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspendec or abandoned for a period of 180 days from the last inspection. M07 -212 Printed: 10 -10 -2007 Parcel No.: 2623049081 Address: Suite No: Tenant: VERIZON WIRELESS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17100 SOUTHCENTER PY TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -212 ISSUED 10/04/2007 10/10/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) doc: Cond -10/06 M07 -212 Printed: 10 -10 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 16: Local U.L. central station supervision is required. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -212 Printed: 10 -10 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -10/06 Date: /6—/° d 7 M07 - 212 Printed: 10 -10 -2007 Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: ,?Ao S t c- w) Contact Person: 6l2 Eti T ki 5 s cr.,. E -Mail Address: Contractor Registration Number: V /5 /tom! E /''1 ' 730 6 T Company Name: Mailing Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: CITY OF 1 UKWIL Community Developm impartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us 2,0 o S1 32 St ^ ?o 7)15 Yh ec(1c,, ; c a,( Q:Upplications\Forms- Applications On Line\1 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh MECHANICAL PERMIT APPLICATION SITE LOCATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** city Fax Number: King Co Assessor's Tax No.: Site Address: / 7 /on SG & 1•C { / e c / in Suite Number: /16 Floor: Tenant Name: v r,Z rz CA) l.JJ:CA E L £ 55 New Tenant: p.... Yes 0 ..No Property Owners Name: (J.),- Gr 14 O P E T L S 41_ C 55 Mailing Address: 9-g 1 S E /34 • AL , /leA 1 c ✓ti- City wt} State State State 9 F006 Zip CONTACT PERSO --who do we contact when your permit is ready to be issued R A EA/ T / k i S 5 t r✓— Day Telephone: F6v — ��� 5 933 Cu ay CAJi, State Zip MECHANICAL CONTRACTOR INFORMATION - F'ede, -.A L a , cv,- City Day Telephone: 360 gr 8 S 933 Fax Number: Expiration Date: State Zip /- ?° - 2CO I ARCHITECT OF RECORD A ll plans must be wet stamped by Architect of Record Zip City Day Telephone: Fax Number: I ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Recor Company Name: Mailing Address: Zip City Day Telephone: Fax Number: Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM p Incinerator — Comm/Ind Other Mechanical Equipment Valuation of Project,(contractor's bid price): $ �� 0 Scope of Work (please provide information): e I 1 we f/<' C y // 5 I V # C , o-P TU l l�fS t,J PLA C -" pfop S te/ *D 5 " Ft f to ✓ Pl, 5+1 + � � . . .. 7 - e ti a X . i i .l ( 2. E A s & I 7 k s)( lna-u f t i '5. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ... Replacement .... ❑ Fuel Type: Electric ❑ Gas ... Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER) AUTHO$IZEDAGENT: Signature: Print Name: Mailing Address: 1 Date Application Accepted: IDU I i- Q:\AppticationsWorms-Appiications On Linet3 -2006 - Mechanical Permit Application.doc Revised: 4.2006 bh Other: Date: /0 - ! - L 7 ER E / AdK SSoi" Day Telephone: 366 - c 9 3 ?n, c S , 5 C - -Yo c,J a &'4 .1g 3 City State Staff Initials: Page 2 of 2 Doc: RECSETS -06 RECEIPT NO: R07 -02206 Initials: JEM User ID: 1165 Payee: BRENT ADKISSON City of Tukwila SET TRANSACTIONS: Set Member Amount Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.dtukwila.wa.us SET ID: 1010 SET NAME: D15 M07 -212 215.58 PG07 -262 88.00 PG07 -263 88.00 PG07 -264 88.00 TOTAL: 479.58 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Cash 479.58 TOTAL: 479.58 ACCOUNT ITEM LIST: Description GAS - NONRES MECHANICAL - NONRES Account Code Current Pmts 000/322.100 000/322.100 TOTAL: 479.58 Payment Date: 10/10/2007 Total Payment: 479.58 264.00 215.58 1)/10 q710 TOTAL RECEIPT NO: R07 -02172 Initials: JEM User ID: 1165 Payee: BRENT ADKISSON SET TRANSACTIONS: Set Member Amount M07 -212 54.00 PG07 -262 22.00 PG07 -263 22.00 PG07 -264 22.00 TOTAL: 120.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http. / /www. ci. tukwila. wa. us SET RECEIPT SET ID: S000000872 SET NAME: Tmp set/Initialized Activities TRANSACTION LIST: Type Method Description Amount Payment Cash 120.00 TOTAL: 120.00 Account Code Current Pmts 000/322.100 6.08 000/345.830 113.92 TOTAL: 120.00 Payment Date: 10/04/2007 Total Payment: 120.00 Prs,j9ct: , //Pr"' 7o)ti Type of Inspection: r 1/ Al / .., Address: '" /740 O 3/4 DatCalled: A% Special Instructions: Date Wanted: a.m. Requester: Phone No - S(3 ? 3 INSPECTION RECORD INSPECTION NO. Retain a copy with permit MO 7 zi PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 7 COMMENTS: O rfri- 7 0/,k4),x4 , -/ A Inspec Date: .00 REINSPECTION FEE EQUIRED.,For to inspection, fee must be paid at 6300 Southcenter Blv Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: Approved per applicable codes. Corrections required prior to approval. Project: _ / /iri,G, Kji /" . � ( Type of Inspection: S ,p\54l//�l viv Address: /7/0 o SenilhocAth Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone o: O �G _/� � a�'0, , 2 - fit' 33 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 e 7 - 2( PERMIT NO. COMMENTS: Insp- to Date O' .00 REINS • ECTION FEE • EQUIRED. • for to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 1 0. Call the schedule reinspection. eceipt No.: Date: Approved per applicable codes. Corrections required prior to approval. Project: l je! ?..e ^ ZJ Fetes S Type of Inspection: ---- \.. SAL v kt Le ri2t r - "�« - f OR Address: ( '716 n 5 ov ceikier p . cay Date Called: - Special Instructions: 1l Date Wannted. /:..� (Al p.m. p.m. Reques Phone No: 3 (,0- ST zi 33 INSPECTION RECORD Retain a copy with permit INSPE• ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 El Approved per applicable codes. COMMENTS: klyr r - (insPe or: ajIL k Corrections required prior to approval. $58.00 REINSPECTION FEE R UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: OU/ 7/0A w' 1 al Type y a of Inspection: -04- . Address: OW fa�j Cc CI Pkc�tid Date Callgd: Special t ructions: ( toWanted: E I , f '` -- U C(1/ �.m. Wm Requeste Phone No: 36 0 — k e - _s INSPECTI 'N NO. INSPECTION RECORD Retain a copy with permit M 7-2,f2 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ctt•.eitA Inspe Date El $58.00 REINSPECTION FE EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: Typ of Ins ection: Addr7s / v 5Jwl& � � - mate /` Calle Special Instructions: I � � q 1 A- / D a Wanted: I � v / ( P.m. Requester: Phone No 314 11-0 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -36 Corrections required prior to approval. COMMENTS: / $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: HVAC EQUIPMENT SCHEDULE - YORK ROOF TOP UNITS (208/230- 3Phase) Unit # CFM Type of Heat Model # Cooling Capacity EER Heat Input Max Fuse Size RTU 116 -1 2600 Packaged Gas DCG 078 75,000 BTU (H) 10.5 EER 120K BTU 45 AMP RTU 116 -2 3000 Packaged Gas DCG 090 87,000 BTU (H) 10.5 EER 120K BTU 50 AMP All Units Complete with Disposable Filters, Economizer w/ Hood, Smoke Duct Detector & Thermostat SCOPE OF WORK Install 2 ea. New York Predator HVAC Roof Top Units Install 2 ea. New Bath Exhaust Fans (Vent thru roof) Install 2 ea. New 1" Gas lines from Existing 2" Pipe to HVAC Units Provide 2 ea Honeywell Thermostats for future Tenant Installation BY Y Date: — /o —Q 7 Plan review approval Is subject to errors and omtssi Approval of con ruction documents does not authorize the violation c,'• cr. code or ordinance. Receipt Of appr o c-J ; : ' ' - ` ccnditions Is ad not vledged: City of Tukwila BUILDING DIVISION Single Gas Line Hanging Detail 2" Square Washer w /nut Bar Joist 3/8" All Thread Loop Pipe Hanger SEPARATE PERMIT REQUIRED FOR: ❑i echanical • LLL Electrical Electrical Qr,Plumbing ffl Gas Piping City of Tukwila BUILDING DIVISION po i zi 4 0 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j i • 100 c*n Bath EaMwl Fin (Wnl Thru Roof) MCA 1P 'CI New 1" Gas IHVAC Rooi o Pr RTU 116 -1 6.5 Ton York rir=-1 °11 1 §DI'IG ''N', FLOOR PLR 41 .1 .0 f VCR R LL. MIM �E RIZI N 10 :'IR EL -SR. RECEIVED CITY OF TUKWIlA OCT 0 4 2007 PEHMI r CENTER Verizon Wireless Southcenter Square 17100 Southcenter Pkwy Tukwila, WA 98188 Suite #116 D15 MECHANICAL 2020 S. 320th St #C -90 Federal Way, WA 98003 O121t HVAC PLANS M - TECHN GUIDE LIYORIC Heating and Air Conditioning r fi-E,pAre l ® MID EFFICIENCY SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS /ELECTRIC UNITS DF 078, 090, 102 and 120 6-1/2, 7 -1/2, 8 -1/2 and 10 NOMINAL TONS 10.4 EER RECEIVED CITY OF TUMNII_A OCT 0 4 200/ PEHMIT CENTER 036- 21491-004- A-0405 DESCRIPTION ASHRAE 90.1 COMPLIANT YORK DF Predator units are convertible single packages with a common footprint cabinet and common roof curb for all 6- 1/2 through 10 ton models. All units have two compressors with independent refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All DF Predator units are self- contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Inde- pendent economizer designs are used on side and down dis- charge applications, as well as all tonnage sizes. Predator units are available in the following configurations: cooling only, cooling with electric heat, and cooling with gas heat. Electric heaters are available as factory- installed options and field- installed accessories. Tested in accordance with: FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE AAD4 242. Component Models A'0711 ' ' 000 ' 102 120 Evaporator Blower Blower, Centrifugal (Dia. X Wd. in.) 15 x 15 12 x 12 12 x 12 15 x 15 Motor, Standard (HP) 1.5 2 3 2 Motor, Optional (HP) 2 3 3 3 Evaporator Coil Rows 3 3 3 4 Fins per Inch 15 15 15 15 Height (in.) 32 32 32 40 Face Area (ft. 10.67 10.67 10.67 13.2 Condenser Fan (2 per Unit) Propeller Dia. (in.) 24 24 24 24 Motor (HP, each) 1/3 1/3 3/4 3/4 CFM, Nominal (each) 1700 1700 2200 2200 Condenser Coil (2 per unit) Rows 1 1 Sys 1: 2 Row 2 Sys 2:1 Row Fins per Inch 20 20 20 20 Height (In.) 44 36 36 44 Face Area (ft. 14.5 12 12 14.5 Refrigerant Charge System 1 (lb/oz) 6/12 5/4 9/12 11/1 System 2 (lb/oz) 6/4 5/0 5/6 11/1 Compressors Quantity 2 2 2 2 Type Reap Redp Reap Redp Air Filters Size (Wd. x Ht. x Thickness in.) 25x20x2 25x16x2 25x16x2 25x20x2 Number Per Unit 4 4 4 4 TABLE 2: DF PHYSICAL DATA 036- 21491 -004- A-0405 14 Unitary Products TABLE 3: DF CAPACITY RATINGS Size (Tons) Model Cooling Capacity ARI Ratings CFM Sound Rating (dB)t Nominal Electric Heat Capacity* (may) Gas Heat Capacity Gas Line Size (in. OD) 504 - IPLV Input (MBH) t Output (MBH) Efficiency (%) Temp. Rise ( °F) (6 -112) Cooling Only 75 10.4 11.0 2600 84 - - - - - - Electric Heat 9, 18, 24, 36 - - - - - Gas Heat - 120 96 80 20-50 3/4 Gas Heat - 180 144 80 35-65 3/4 (._. Coding Only 87 10.5 11.6 2516 84 - - - _ - - Heat 18, 36 - - - - - Gas Heat - 120 96 80 15-45 3/4 Gas Heat - 180 144 80 30-60 3/4 102 (8 - 1/2) Coding Only 99 10.4 10.39 3055 84 - - - - - Ekddrrc Heat 9, 18, 24, 38 - - - - - Gas Heat - 120 96 80 15-45 3/4 Gas Heat - 180 144 80 30-60 3/4 (10 ) Coding Only 115 10.4 10.0 4000 . _ _ - - - _ Electric H 18, 24, 36, 55 - - - - - Gas Heat - 180 144 80 20-50 3/4 Gas Heat - 240 192 80 35-65 3/4 TABLE 4: UNIT VOLTAGE LIMITATIONS POWER RATING MIN. MAX. 208/2303 -60 187 252 460-3-60 432 504 575 -3460 540 630 036 - 21491 -004-A -0405 • Rated at 95 °F ambient 80 °F dry bulb and 67 °F wet bulb t Rated in accordance with ARI 270 standard. 1 See Table 17. Unitary Products • The capacities are gross ratings. For net capacity, deduct Indoor blower motor, MBH =3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. t Input power includes the condenser and compressor motors but not the indoor blower motor. 15 Voltage Compressors OD Fan Motors $uppty Blower Motor FLA Pwr Exh Motor Its Electric Heater Model No. IJi 1 Min. Circuit paclty wlPower Exhaust (Amps) Max Fuse* Size (Amps) Max Fuse* Size w!Power Exhaust (Amps) Max Fuse* Size wlPower Exhaust (Amps) RLA ea. LRA ea. FLA ea. 1.5 HP 2 HP FLA FLA 1.5 HP 2 HP 1.5 HP - r 1.5 HP 2 HP 1.5 HP 2 HP 208 10.6 78.0 1.5 6.2 82 5.5 0.0 None - - 33.1 35.1 38.8 40.8 40 45 45 50 2TPO4520925 6.8 18.9 33.1 35.1 38.6 40.7 40 45 45 50 2TPO4521825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70 2TPO4522425 18.0 50.0 702 727 77.1 79.6 80 80 80 80 2TPO4523625 25.5 70.8 962 98.7 103.1 105.6 100 100 110 110 230 10.6 78.0 1.5 62 8.2 5.5 " 0.0 None - - 33.1 35.1 38.6 40.6 40 45 45 50 2TPO4520925 9.0 21.7 34.8 37.3 41.7 442 40 45 45 50 2TPO4521825 18.0 43.3 61.9 64.4 68.8 71.3 70 70 70 80 2TPO4522425 24.0 57.7 79.9 82.4 86.8 89.3 80 90 90 90 2TPO4523625 34.0 81.8 110.0 112.5 116.9 119.4 110 125 125 125 460 52 . 40.0 0.8 3.1 4.1 2.2 0.0 None - - 16.4 17.4 18.6 19.6 20 20 N R tg i 20 2TPO4520946 9 11.3 17.4 18.7 202 21.4 20 20 25 35 2TPO4521846 18 22.8 30.9 322 33.7 34.9 35 35 2TPO4522446 24 30.1 40 412 42.7 44 40 45 45 45 2TPO4523646 34 42.7 55 562 57.7 59 60 60 60 60 575 4.1 32.0 0.6 2.4 3.6 1.8 0.0 None - - 12.8 14 14.6 15.8 15 15 15 20 2TPO4520958 9 9.0 13.8 15.3 16.1 17.6 15 20 20 20 2TPO4521858 18 18.1 24.7 262 26.9 28.4 25 30 30 30 2TPO4522458 24 24.1 31.9 33.4 34.1 35.6 35 35 35 40 2TPO4523658 34 34.1 43.9 45.4 46.1 47.6 45 50 50 50 • Me Imt m HACR breaker of the same AMP size is aoolicable. Voltage Compressors OD Fan Motors Supply Blower Motor FLA Pwr Exh Motor Its Electric Heater Model No. Actual KW Heater Amp s ) Min. Circuit �� MCA wlPower Exhaust (Amps) Max Fuse* Size (Amps) Max Fuse* Size w!Power Exhaust (Amps) RLA LRA FLA ea. 1.5 HP 2 HP FLA • 1.5 HP 2 HP 1.5 HP 2 HP 1.5 HP 2 HP 1.5 HP 2 HP 208 10.6 78.0 1.5 8.2 82 5.5 10.0 None - - 43.1 45.1 48.6 50.6 50 50 50 60 2TPO4520925 6.8 18.9 43.8 46.3 50.7 53.2 50 50 60 60 2TPO4521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80 2TPO4522425 18.0 50.0 82.7 852 89.6 92.1 90 90 90 100 2TPO4523625 25.5 70.8 108.7 1112 115.6 118.1 110 125 125 125 230 10.6 78.0 1.5 62 8.2 5.5 10.0 None - - 43.1 45.1 48.6 50.6 50 50 50 60 2TPO4520925 9.0 21.7 47.3 49.8 54.2 56.7 50 50 60 60 2TPO4521825 18.0 43.3 74.4 76.9 81.3 83.8 80 80 90 90 2TPO4522425 24.0 57.7 92.4 94.9 99.3 101.8 100 100 100 110 2TPO4523625 34.0 81.8 122.5 125.0 129.4 131.9 125 125 150 150 460 52 40.0 0.8 3.1 4.1 22 5.0 None - - 21.4 22.4 23.6 24.6 25 25 25 25 21PO4520946 9 11.3 23.7 24.9 26.4 27.7 25 25 30 30 2TPO4521846 18 22.6 372 38.4 39.9 41.2 40 40 40 45 27PO4522448 24 30.1 462 47.5 49 50.2 50 50 50 60 2TPO4523646 34 42.7 612 62.5 64 652 70 70 70 70 575 4.1 32.0 0.6 2.4 3.6 1.8 4.0 None - - 16.8 18 18.6 19.8 20 20 20 20 2TPO4520958 9 9.0 18.8 20.3 21.1 22.6 20 25 25 25 21PO4521858 18 18.1 29.7 312 31.9 33.4 30 35 35 35 2TPO4522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 45 2TPO4523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60 • Maximum HACR breaker of the same AMP size Is aoolMsble. 20 036 - 21491 -004-A -0405 TABLE 9: ELECTRICAL DATkDF078 (6 -112 TON) MID EFFICIENCY W!O PWRD CONVENIENCE OUTLET TABLE 10: ELECTRICAL DATA DF078 (6 -112 TON) MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET Unitary Products Volta Compressors CO Fan Motors SuPPiy Motor FLA [IF Fir ic Heater Electr eater Model No I 11 I It Min. Circuit Ampacity (Amps) MCA w/Power Exhaust (Amps) Max Fuse' Size (Amps) Max Fuse Size lP or Exhaust w r RLA LRA FLA 2 HP 3 HP FLA FLA 2 HP 3 HP 2 HP 3 HP 2 HP 3 HP 2 HP 3 HP ei sa. ea. 208 12.8 84.0 1.5 82 10.9 5.5 0.0 None - - 40.0 42.7 45.5 48.2 50 50 50 s0 2TPO4540925 6.8 18.9 40.0 42.7 45.5 48.2 50 50 50 60 2TPO4541825 13.5 37.5 57.1 80.5 64.0 87.3 80 70 70 70 2TPO4542425 18.0 50.0 72.7 78.1 79.6 83.0 80 80 80 90 2TPO4543625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110 230 12.8 84.0 1.5 8.2 10.9 5.5 0.0 None - - 40.0 42.7 45.5 482 50 50 50 60 2TPO4540925 9.0 21.7 40.0 42.7 45.5 482 50 50 50 60 2TPO4541825 18.0 43.3 64A 67.8 71.3 74.6 70 70 80 80 2TPO4542425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100 21PO4543625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125 460 6.8 42.0 0.8 4.1 5.3 22 0.0 None - - 18.8 20 21 22.2 20 25 25 25 2TPO4540948 9 11.3 18.8 20.2 21.4 22.9 20 25 25 25 2TPO4541846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40 2TPO4542448 24 30.1 41.2 42.7 44 45.5 45 45 45 50 2TPO4543848 34 42.7 56.2 57.7 59 60.5 60 80 60 70 575 5.1 34.0 0.6 3.8 4.1 1.8 0.0 Nora - - 16.3 16.8 18.1 18.8 20 20 20 20 2TPO4540958 9 9.0 18.3 18.8 18.1 18.6 20 20 20 20 2TPO4541858 18 18.1 262 26.8 28.4 29 30 30 30 30 27954542458 24 24.1 33.4 34 35.8 36.2 35 35 40 40 2TPO4543658 34 34.1 45.4 46 47.6 48.3 50 50 50 50 Voltage Compressors OD Fan Motors SuPPtY Blower Motor FLA [IF I 11 I if Min. Circuit Ampacity (Amps) MCA wlPower Exhaust (Amps) Max Fuse• Size (Amps) Max Fuse She wlPower Exhaust (Amps) RLA LRA FLA 2 3 FL.A FLA 2 3 2 3 2 3 2 3 Oil es. ea. HP HP HP HP NP HP HP HP HP HP 208 129 84.0 1.5 82 10.9 5.5 10.0 None - - 51.1 53.8 56.8 59.3 60 60 80 70 2TPO4540925 6.8 18.9 51.1 53.8 58.8 59.3 80 60 60 70 27PO4541825 13.5 37.5 69.8 73.0 76.5 79.8 70 80 80 80 2TPO4542425 18.0 50.0 852 88.6 92.1 95.5 90 90 100 100 21954543E25 25.5 70.8 1112 114.6 118.1 121.5 125 125 125 125 230 12.8 84.0 1.5 8.2 10.9 5.5 10.0 None - - 51.1 53.8 56.6 59.3 80 80 60 70 2TPO4540925 9.0 21.7 61.1 63.8 58.7 60.1 80 80 60 70 27PO4541825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90 2TPO4542425 24.0 67.7 94.9 98.3 101.8 105.2 100 100 110 110 2TPO4543625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150 460 5.8 420 0.8 4.1 5.3 2.2 5.0 None - - 28.7 27.9 28.9 30.1 30 30 35 35 2TPO4540946 9 11.3 28.7 27.9 28.9 30.1 30 30 35 35 2TPO4541846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45 21954542446 24 30.1 47.5 49 502 51.7 50 50 60 60 2TPO4543646 34 42.7 82.5 64 652 66.7 70 70 70 70 575 6.1 34.0 0.6 3.6 4.1 1.8 4.0 None - - 21.7 22.2 23.5 24 25 25 25 25 2TPO4540958 9 9.0 21.7 222 23.5 24 25 25 25 25 2TPO4541856 18 18.1 31.2 31.8 - 33.4 34 35 35 35 35 2TPO4542458 24 24.1 38.4 39 40.8 41.2 40 40 45 45 2TPO4543658 34 34.1 50.4 51 52.6 53.3 60 60 60 60 036- 21491 -004 -A -0405 TABLE 11: ELECTRICAL DATA DF090 (7 -1/2 TON) MID EFFICIENCY W/O PWRD CONVENIENCE OUTLET TABLE 12: ELECTRICAL DATA DF090 (7 -1/2 TON) MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET Unitary Products 21 Model Locations (lbs.) A B C D E F DF078 158 142 128 187 207 231 DF090 137 112 93 145 175 214 DF102 138 113 93 146 176 216 DF120 178 160 144 210 233 260 Model Location (lbs.) A B C D DF078 231 197 288 337 DF090 195 146 228 306 DF102 197 147 230 309 DF120 260 222 324 379 TABLE 33: UNIT WEIGHT Model Shippin Weight (lbs.) Operating Weight (lbs.) DF078 1058 1053 DF090 875 870 DF102 888 883 DF120 1190 1185 ECON. 85 84 PE 150 148 GAS HEATt 110 100 ELEC. HEAD 49 49 Unit Model Number X Y DF078 471/2 251/2 DF090 38 23 DF102 38 23 DF120 471/2 2512 FIGURE 4 - UNIT 4 POINT LOAD TABLE 31:4 POINT LOAD WEIGHT • Weights include largest heating option. FIGURE 5 - UNIT CENTER OF GRAVITY F FIGURE 6 - UNIT 6 POINT LOAD TABLE 32:6 POINT LOAD WEIGHT • Weights include largest heating option. t 8 tube gas section. $ 54kW heater. 036 36 Unitary Products CT EN GINE Structural Engineers PLLC STRUCTURAL CALCULATIONS For HVAC Roof Top Units Verizon North Building @ Southcenter Squar Tukwila, WA -: C • G c j "!r M o • EXPIRES: 7/27 7 IFILE COPY 7- * 1 C A,013\\ b �^L/. 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285- 4512(V) (206) 285 -0618(F) RECEIVED CITY OF TUKWII_ OCT 0 4 2007 PEHNii t CENTER 24 2 ? 0 0 ft% C� E N G I N E E R I N G P L L C t' C1� Protect: h1 0�Y r 1 1. — JQO K'.Et�11C .( U C�.(r Ohl. Date: ? — Client: Page Number: 1, i4- EW TH LC: oN c F ` =F :. Tttt sY.e:V K T, PLt ./....E.1 t t Eller FIR.ONtr ;-ET:4 h : �3.; -�n,t; :=.� ' 4E , -Tit-E. G ds ^ .1 l.-�., ='.''` °c t. 11t ►� t` ! 1��,,c�� C.2� ! H� 20\L toeD l"-c'2 1..c ;��. ►5 Cg c7 c, LoCZA 1 J U w h1 V „ , Fr= e4 (t+a OP .7 (.47C " -- 11.,p Fr = • ` C Looms t S 24,2 Tic. L) tV t S 2D IQ "Ilia C. to s t t∎Lr Tft 6..) R" Is To . i : c �ot.:;•�' 'i i c fJ !mil ! 7'�- 12 S . Z'= J t f°rtJ` 1.-towit 4t h !At ' . COWES till T. If ry. .' -L n • r "' L `VV .°. ) t ��aT 21 E 946 — Suite 302 Seattle, WA 98109 (206) 285 -4512 FAX: (206) 285 -0618 a`1 TOP ACTIVITY NUMBER: M07 -212 DATE: 10 -04 -07 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 17100 SOUTHCENTER PY, STE 116 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENT V Buildingir ivision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: �doa aaooa liw83d � PLAN REVIEW /ROUTING SLIP Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required DATE: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: 4 / j1'O ' 1 Fire Prevention Structural ❑ DATE: Planning Division Permit Coordinator DUE DATE: 10-09-07 Not Applicable C DUE DATE: 11-06-07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 License Information License DI5MEM *930BT Licensee Name D15 MECHANICAL Licensee Type CONSTRUCTION CONTRACTOR UBI 601841514 Ind. Ins. Account Id Business Type INDIVIDUAL Address 1 2020 S 320TH ST #C -90 Address 2 City FEDERAL WAY County KING State WA Zip 98003 Phone 3608885433 Status ACTIVE Specialty 1 AIR HEAT,VENTILATION,EVAPORAT Specialty 2 SHEET METAL Effective Date 1/30/2007 Expiration Date 1/30/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ADKISSON, BRENT OWNER 01/30/2007 ...,...� � ..... ...... a. .......... �.....,LA. A./WA/AAA j Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information No Matching Information Savings Information Savings Bank Name Bank Branch Location Assignment of Savings Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 a5V 1 VL !r https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= D15MEM *930BT 10/10/2007