Loading...
HomeMy WebLinkAboutPermit M07-221 - VERIZON WIRELESSVERIZON WIRELESS 17100 SOUThCENTER PY STE 116 EXPIRED 08 -05 -OS M07 -221 Parcel No.: 2623049081 Address: Suite No: DESCRIPTION OF WORK: MECHANICAL FOR NEW TI doc: IMC -10/06 Citf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17100 SOUTECENTER PY TUKW Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA Contact Person: Name: DERRICK PRODIGALIDAD Address: 13648 BURBANK , SHERMAN OAKS CA Contractor: Name: MARKET CONTRACTORS LTD Address: 10250 NE MARX ST , PORTLAND OR Contractor License No: MARKEL *213JR Value of Mechanical: $13,200.00 Type of Fire Protection: SPRINKLERS Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT Tenant: Name: VERIZON WIRELESS Address: 17100 SOUTHCENTER PY, STE 116 , TUKWILA WA EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 1 0 1 0 * *continued on next page ** M07 -221 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 818 786 -8960 Phone: 503 255 -0977 Expiration Date: 09/10/2008 M07 -221 12/14/2007 06/11/2008 Fees Collected: $315.68 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP/100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP/1,000,000 BTU.. 0 30 -50 HP/ 1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 Printed: 12 -14 -2007 Permit Center Authorized Signature: Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -221 Issue Date: 12/14/2007 Permit Expires On: 06/11/2008 Date: 144 k I hereby certify that I have read and xanned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie vin , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. 3A , t%' Date: /107 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspendec or abandoned for a period of 180 days from the last inspection. doc: IMC M07 -221 Printed: 12 -14 -2007 Parcel No.: 2623049081 Address: Suite No: Tenant: VERIZON WIRELESS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17100 SOUTHCENTER PY TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -221 ISSUED 10/15/2007 12/14/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the doc: Cond -10/06 M07 -221 Printed: 12 -14 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 - 3670) is required for this project. 21: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -221 Printed: 12 -14 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: k 01 / / fgDk Date: ! .V �/ /�f ordinances governing or local laws regulating doc: Cond - 10/06 M07 -221 Printed: 12 -14 -2007 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http • tvu w. ci. tultia ila. wa. us SITE LOCATION Site Address: I1 1 d C t.a■ u rya Tenant Name: \Je ri ZerY\ L&11AL - / Property Owners Name: Mailing Address: City CONTACT PERSON — who do we contact when your permit is ready to be issued Name. Wick {turd Mailing Address: Contact Person: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** E -Mail Address: a E : AAA e pp lcte r eV t» GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Contact Person: �> E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name?% lf'S1Ct' x-3■ Mailing Address: a t ,Q r � r is Contact Person: c/P ` `e E -Mail Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name e ► o.t vt,.o-p iR Mailing Address: '>2 Let'' e E - Mail Address: Q:Mpplications\Porms-Applications On line\ -2006. Pemtit Application.doc Revised: 9.2006 bb City Building Permit No. DO Mechanical Permit No. D Plumbing/Gas Permit No e40--_- Public Works Permit No. Project No. o (For office use only) King Co Assessor's Tax No.: 2.0 201 - 1O I Suite Number: l I to Floor: New Tenant: 13' Yes ❑..No State Day Telephone: et p, - i `1 coo Fax Number. City Day Telephone: Fax Number. Expiration Date: State c Ait ,,QA O16 I/S State Zip ct l� t,esl Zip Zip i ty State Zip Day Telephone: 17. "x'74 // Fax Number. to(o a(k-( Zip I-Pt - City Day Telephone: Fax Number. Page 1 of 6 BUILDING PERMIT INFORTION — 206- 431 -3670 g 191 Valuation of Project (contractor's bid price): $-- y 0 e?" Existing Building Valuation: $ Scope of Work (please provide detailed information): ne a - Chat Or al Stec t J� —g- n1 Celith tY1011 C v Q i v e vvo , { i t" IM e c lAa vI iA c t,d 7lu ∎4% , v Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below l St Floor 2 Floor 3 Floor Floors Basement Accessory Structure* <` Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Existing N/R i\i/Pc U kVA A Interior Remodel Z,3S8 Addition to Existing Structure Type of Type of Construction per Occupancy per IBC IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ve No If "yes', attach list of materials and storage locations on a separate 8 - 1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\ Applications \Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 ewer District .. .Tukwila ❑ ...Sewer Use Certificate ❑ ...Total Cut ❑ ... Total Fill cubic yards cubic yards PUBLIC WORKS PERMIT INFORMATION — 206- 433 -0179 Scope of Work (please provide detailed information): Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Septic System: b On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 0 bmitted with Application (mark boxes which apply): ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0 onosed Activities (mark boxes that apply): ...Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ .. Right -of -way Use — Potential Disturbance ❑ ... Construction /Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection Irrigation " Domestic Water " ❑ ...Permanent Water Meter Size... 11 WO # ❑ ...Temporary Water Meter Size .. 11 WO # ❑ ...Water Only Meter Size 11 WO # ❑...Deduct Water Meter Size " ❑ ...Sewer Main Extension Public _ Private ❑ ...Water Main Extension Public _ Private FIN CE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip Q:1 Applications Tomu- Appliations On Line\3.2006 - Permit Appliation.doc Revised: 9 bh Call before you Dig: 1400 -424 -5555 ❑ .. Higltline ❑ ...ValVue ❑ .. Renton ❑ ...Sewer Availability Provided ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Renton ❑ .. Seattle Page 3 of 6 Unit Type: Qty Unit Type: Qty ' Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System f Wood/Gas Stove 30 - 50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic / Other Mechanical tpment u i xiT L/» 6a, S Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Company Name: MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number. Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): Sa D " Scope of Work (please provide detailed information): Prop/ it 64/ .slit as ex ,51-1 ow. fie( ghwi - cv JI ✓`a VskW Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .. . Replacement .... ❑ Fuel Type: Electric ❑ Gas —.0 Other: Indicate type of mechanical work being installed and the quantity below: Q: Upplicafions\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 - 2006 bh Page 4 of 6 Fixture Type: Qty Fixture Type:. Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain I Sinks 4- Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory /� Water Closet n ''' Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent i Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 'Vie Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: Applications\Fonns- Applications On Line\3.2006 - Permit Appliation.doc Revised: 9 - 2006 bb Page 5 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R O UTHORIZED AGENT: Signature: � � 4^-- Date: ft)// S Jo 7 Print Name: ZIP.k ' 6 'St9 bI Mailing Address: 31 ?in 2fir' el.- S Date Application Expires: l (sj Date Application Accepted: 011c1/01- Q:Upplications\Fonns- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh Day Telephone: 2S3 X677 — 6g - 7 t'fm'B City State Staff Initials: I Zip Page 6 of 6 Doc: RECSETS -06 RECEIPT NO: R07 -02765 Initials: JEM User ID: 1165 SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http. //www.ci.tukwila.wa.us Payee: MARKET CONTRACTORS (WA) LDT SET ID: 1214 SET NAME: VERIZON D07 -387 1,088.92 M07 -221 258.54 TOTAL: 1,347.46 SET RECEIPT Payment Date: 12/14/2007 Total Payment: 1,347.46 TRANSACTION LIST: Type Method Description Amount Payment Check 11671 1,347.46 TOTAL: 1,347.46 ACCOUNT ITEM LIST: Description BUILDING - NONRES MECHANICAL - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 1,084.42 000/322.100 258.54 000/386.904 4.50 TOTAL: 1,347.46 6043 12/14 9710 TOTAL 1347.46 RECEIPT NO: R07 -02249 Initials: User ID: 1165 Payee: PERMIT PLACE Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: htlp: //www. ci. tukwila. wa. us City of Tukwila SET ID: S000000877 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -387 704.87 EL07 -585 114.80 M07 -221 57.14 PG07 -275 37.00 TOTAL: 913.81 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 6105 913.81 TOTAL: 913.81 Account Code Current Pmts 000.345.832.00.0 114.80 000/345.830 799.01 TOTAL: 913.81 Payment Date: 10/15/2007 Total Payment: 913.81 Project: , uef. z-b \ L) . -(kf1 Type of Inspection: N .e ne Il ee 0 -1 4 4 Address: ,7l oa 5,,,i c 4Ju /If -Cwp Date Called: Special Instructions: �"� ll 2 Drate Wanted: - rl — X' a.rn_, p.m. Requester: Phone No: 5 35t• ---- eflog4 ❑ Approved per applicable codes. M67- Z( INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Corrections required prior to approval. COMMENTS: () ( A : -Or 5» e 5 � ( L JOU' ) - Inspector ' dff El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: IDate: Project: U P1 Zoe W r`C.Q&LJ Type of Inspection: Sit d KC / C - 7 T Sit L J? Address: )'706 S til er /IC I IJA`l Date Called: Special Instructions: /" ( it ( j A ll /Date _ Wanted: Z-47—(3S- __am- p.m. Request Phone No: 503- 3s4/-M4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3671 Ei Approved per applicable codes. Corrections required prior to approval. COMMENTS: nn e �X P --{' { l dr J I Inspector: ' /i Date 7 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project: (/l"/ k, Type of Inspection: \J Sl4, d / « ..5%/?t 711 - Z"/l. Address: /?/' 0 -51,174'Nb/ D t Called: 7 Special Instructions: / Date Wanted: /— d G c.— a.m. C2-- Requester: Phone No: 17/‘ 8'y INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. 12 Corrections required prior to approval. COMMENTS: 1 lnspect: Date J $58.00 REINSPECTION FEE REQI)1RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: , I Iej - Z-o'\ Of/ C Type of Inspection: r rfif 3. Yai :re G Re .' ' Address: C /7/ ,lar f - tJ Date Caller!: Special Instructions: /1 ` 7-- / I- 14 to Wanted: 2 -: 1 ? 6r- P.m. p.m. Requester: Phone No: So 3' 3)F1'1(.08 . 1 INSPECTION RECORD A4 / Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 9' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 Approved per applicable codes. E1 Corrections required prior to approval. 0 COMMENTS: Inspttor: „,u)c /,/ Date: — — o& $58.00 REINSPECTION FEE I Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. A Project: ll Z W;1, PCS1 Type of Inspection: /� tf �v r�{ �� �'�` �-� Address: a Date Ca Special Instructions: lU f}(�� GJ• "uc Date Wanted: / - 11 — cl -- Lam., p.m. Requester: Phone No: 4t INSPECTION NO. INSPECTION RECORD Retain a copy with permit Mn'l -1 21 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 COMMENTS: Approved per applicable codes. El Corrections required prior to approval. Inspect: 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Date: 1, °A' 'Receipt No.: 'Date: Project: VE i o, Sprinklers: Fire Alarm: Type of Inspection: M•kt µivc.. / Fa 4 -. 4 z-- Address: n i c.x) C • Suite #: ii6 • Nti Contact Person: (\AIM, Special Instructions: Phone No.: 603 - Ss , 6 - %-s6 , 64 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 3 INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 .._ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS ri Corrections required prior to approval. COMMENTS: f - AA ' 1\Q, 5 II Inspector: t \J t 9A 5t Date: 2/It /0?? Hrs.: E/K ---74 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from h City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 COMMENTS: Sprinklers: Type of Inspection: Address: r? WO O S c Suite #: /i c, ( r D PPP€ i .- FA ,4 h n r+ Cic Contact Person : '-3a,o� AI, a i r , e Special Instructions: Occupancy Type: - -1-1.) 1- g Ro Ah.,vh . 1 ° 1 - i 4; 4 fk, � • (j) PR —S( k- 4•KE..IR +ei ! 1 - Project: Sprinklers: Type of Inspection: Address: r? WO O S c Suite #: /i c, P; Contact Person : '-3a,o� AI, a i r , e Special Instructions: Occupancy Type: Phone No.: S03-3 -t9ag1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS N Corrections required prior to approval. Inspector: c/ J Date: - _ o Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 07 -15 -2008 DERRICK PRODIGALIDAD 13648 BURBANK SHERMAN OAKS CA 91401 Dear Permit Holder: Guy of Tukwila RE: Permit No. M07 -221 17100 SOUTIICENTER PY TUKW Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 - 2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writin! and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/05/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Ter Marshall it Technician Permit File No. M07 -221 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M07 -221 DATE: 10 -15 -07 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 17100 SOUTHCENTER PY, STE 116 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: d Buiijng s on Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete M Incomplete Comments: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP sir) PERMIT COORD COPY . Approved with Conditions III Al■OG 10 4 Fire Prevention Structural DATE: DATE: Planning Division Permit Coordinator C DUE DATE: 10-16-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 11-13-07 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License MARKEL*213JR Licensee Name MARKET CONTRACTORS LTD Licensee Type CONSTRUCTION CONTRACTOR UBI 600320592 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 10250 NE MARX ST Address 2 City PORTLAND County OUT OF STATE State OR Zip 972201152 Phone 5032550977 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/19/1979 Expiration Date 9/10/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BODEN, JOHN T PRESIDENT 10/31/2001 BROWN, PATRICIA J SECRETARY 01/01/1980 HUGHES, MICHELLE W TREASURER 10/31/1999 SORENSEN, STEVE F VICE PRESIDENT 10/31/2001 DILLON, LENNARD CHIEF EXECUTIVE OFFICER 01/01/1980 07/13/2005 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MARKEL *213JR 12/14/2007 Building: Plumbing: Electrical: Mechanical: Fire: Accessibility: Tenant fit -out of a retail store in a strip center mall, including demolition, mechanical, electrical and plumbing. Construction Type: V -N Use Group: M (Mercantile) Area of Work (Gross): 3,454 sq.ft. Maximum Occupancy (Table 1004.1.2): Retail Sales: 2,388 sf /30 Office: 593 sf1100 Storage & Stock Rooms: 297 sf /300 Total Occupancy: Exit(s) Requirements (Table 1018.1): Plumbing Fixtures (Table 2902.1): Water Closet: Lavatory: Bottleless Water Cooler. (In Lieu of Drinking Fountain) Service Sink: Sprinkler System: ® Yes 0 No Scope of Work Code Analysis 2006 International Building Code 2006 Uniform Plumbing Code 2005 National Electrical Code/NFPA -70 2006 International Mechanical Code 2006 International Fire Code (IFC) A.D.A Guidelines Building Analysis = 80 =6 = 87 Required: 2; A 10/9/07 COVER SHEET Provided: 2 Provided: 2 Provided: 2 Provided: 1 Provided: 1 S Imt.1 Proposed ,Verizon Wireless S }ore . 17100 SDU [11 C>NTEtt PARKN�AY r : ruKWIL'R, WA` SHEET NO. SHEET NO. Key Map DETAIL NO. ELEVATION REFERENCE PLAN OR DETAIL TITLE SHEET NO. ENLARGED PLAN OR DETAIL REFERENCE Architectural Symbols Project Contact DATE DETAIL N0J5HEEr Landlord Leshya Wig Wig Properties 4811 134th PL SE Bellevue; WA 98006 Tell: 425 -957 -4774 Site Plan HH NpiGpFa PARKING RETAIL SALES ROOM NO. 10/10/01 COVER SHEET PEDESTRIAN WALKWAY CONCRETE ELEVATION REFERENCE ROOM DESIGNATION REVISION TRIANGLE DOOR NUMBER PROP P ED VERIZON NIRELE55 STORY SOUTH CENTER SQUARE 11100 SOUTH CENTER FARKNIAY SUITE 116 TUKINILA, WA 98188 BUILDING Sheet Titles Drawing List CS Cover Sheet Architectural Al General Notes & Specifications A2 Accessibility Details and Matrix A3 Demolition & Architectural Plan & Details A4 Reflected Ceiling Plan A5 Soffit Location Plan A6 Architectural Details A7 Furniture and Security Plan A8 Floor Finish Plan & Details A9 Wall Finish & Details A10 Interior Elevations & Details Al 1 Furniture & Millwork Elevations Al2 Exterior Elevations A13 Door , Finish Schedule and Details Fl Fixture List Plumbing P1 Plumbing Plan P2 Plumbing Details & Schedules P3 Plumbing Speciticaitions Mechanical M1 Mechanical Plan M2 Mechanical Details & Schedules M3 Mechanical Specifications Electrical El Electrical Plan & Details E2 Lighting Plan E3 Electrical Panelboard Schedules & Details E4 Electrical Legend, Details & Schedule E5 Electrical Details E6 Electrical Specifications E7 Electrical Specifications EXPI `'E AUG 0 5 2008 RECEIVED CITY OF ~ f I.!` , w.A oar 1 5 L''U r PEHivii I CEiN U) I--- Z W 0 U 0 CI 1 z J U) 1— z W 0 U PROJ. 2007 -0174 DRWN. EC DATE 9 -25 -07 w J W ft Z 0 N W PROPOSED STORE DESIGN FOR: SOUTH CENTER SQUARE 17100 SOUTH CENTER PARKWAY SUITE 116 TUKWILA, WA Architect Dan Stuart Davis, A.I.A 7410 S. US -1 #310 Port St. Lucie, FL 34952 Tel: 772-343-0340 Mechanical / Plumbing / Electrical Henderson Engineers Inc. 8325 Lexana Drive Lexana, KS 66214 Tel: 913-742 -5000 wireless SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical! Plumbing OF Piping City of Tukwila BUILDING DIVISION FILE Y Permit Noy -7,44 Plan review appears! Isigliftlesnorsand smisdons. APProvill otsgaivaiNilimminIscbssnotsulhodze the ==!r By Dees:, 1 � i d7 BUILDING °f Tukwila DIVISION �iEASIONS No changes shall be madeto the scope of work without prior approval of Tukwila Building Qivision. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. i 18x18 10 "0 CSD -1 300 10x 10 10 "0 CSD -1 250 10X10 _1_8x1_Q ..._ 10 "0 CSD-1 250 10x10 10 "4 CSD -1 250 22x12 TECH 8" 0 CSD -1 150 18x12 50 _1 ilk?, 8 "CA • CSD -2 \ 50 .8x8 CEO - [LC H LSKOM 10 JANIT fR CL. 22x22 CRG -1 OCRU -1 RTU -2 TELCO 105 l CUSTOVER SERVICE 1.1 10 "0 CSD -1 300 10"0 CSD -1 300 10 "0 CSD -1 300 O r co x co N 22x22 ,CRG -1 — 'L (TYP 2) - a x 0 COPVFAX r 1 1 MI 11114, 28x12 10"0 CSD -1 300 10 "0 CS� f_ — ( A i f0- ES i jr ____ 11 1 1 t � f ____1.-1------ = Y t i` 1 1 _r t 1 t RETAIL SALES 0 10 "0 CSD -1 300 -T tix 11 ~ (©► nEr ‘; CA 10x12 -s- t--- — • 10"O CSD -1 300 10x12 MECHANICAL SYMBOLS I NOTE NECESSARILY USED ON LEGEND THE AND DRAWINGS. ALL SYMBOLS, ETC. ARE PIPING CD ACD RL RD RS HWS — — HWR — — CWS — —CWR— — HS -- -HR LPS —LPC- 14-4 — ti 4.1 ---zl 9 I � to CONDENSATE DRAIN (CD) AUXILIARY CONDENSATE DRAIN (ACD) REFRIGERANT LIQUID (RL) REFRIGERANT DISCHARGE (HOT GAS) (RD) REFRIGERANT SUCTION (RS) HEATING HOT WATER SUPPLY (HWS) HEATING HOT WATER RETURN (HWR) CHILLED WATER SUPPLY (CWS) CHILLED WATER RETURN (CWR) HEAT PUMP SUPPLY (HS) HEAT PUMP RETURN (HR) LOW PRESSURE STEAM SUPPLY (LPS) LOW PRESSURE STEAM CONDENSATE (LPC) EXISTING PIPING TO BE REMOVED EXISTING PIPING TO REMAIN DIRECTION OF FLOW BALL VALVE CONTROL VALVE THREE —WAY CONTROL VALVE SHUTOFF VALVE CHECK VALVE BALANCING VALVE WITH PRESSURE PORTS TRIPLE DUTY VALVE WITH PRESSURE PORTS WATER METER STRAINER SOLENOID VALVE PRESSURE GAUGE THERMOMETER UNION FLANGE CONNECTION ELBOW UP ELBOW DOWN TEE UP TEE DOWN HVAC EQUIPMENT & DUCTWORK NOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. SEE SECTION 15250 OF THE SPECIFICATION FOR DUCTWORK TO RECEIVE INSULATION OR LINER. Jr L FD FIRE DAMPER FIRE SMOKE DAMPER SMOKE DAMPER VOLUME DAMPER MOTORIZED DAMPER BACKDRAFT DAMPER EXISTING DUCTWORK OR EQUIPMENT TO REMAIN EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED BRANCH DUCT WITH 45' RECTANGLE —ROUND BRANCH FITTING AND MANUAL VOLUME DAMPER ELBOW WITH TURNING VANES RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN SUPPLY AIR DUCT UP SUPPLY AIR DUCT DOWN EQUIPMENT WITH FLEXIBLE DUCT CONNECTION 10" CSD -1 300 CFM NECK SIZE, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER MANUAL VOLUME DAMPER SQUARE TO ROUND TRANSITION DUCT MOUNTED• SMOKE ' DETEGTDR (5D ..SU w�'LY� /. RD RELUF2N� CO2 HS CARBON DIOXIDE SENSOR HUMIDITY SENSOR PS PULL STATION IsPj STATIC PRESSURE SENSOR TEMPERATURE SENSOR JTS� 0 HUMIDISTAT O THERMOSTAT ABBREVIATIONS AFF BAS BD CFM Doc DX EA FFA FFB GPM IN WC MAX MBH ABOVE FINISHED FLOOR BUILDING AUTOMATION SYSTEM BACKDRAFT DAMPER CUBIC FEET PER MINUTE DIRECT DIGITAL CONTROL DIRECT EXPANSION EXHAUST AIR FROM FLOOR ABOVE FROM FLOOR BELOW GALLONS PER MINUTE INCHES OF WATER COLUMN MAXIMUM 1000 BTU PER HOUR MC MIN NC OA RA SA SD TFA TFB TYP UNO W/ W/O MECHANICAL CONTRACTOR MINIMUM NOISE CRITERIA OUTSIDE AIR RETURN AIR SUPPLY AIR SMOKE DUCT DETECTOR TO FLOOR ABOVE TO FLOOR BELOW TYPICAL UNLESS NOTED OTHERWISE WITH WITHOUT STANDARD MOUNTING HEIGHTS MECHANICAL THERMOSTATS (USER ADJUSTABLE) CONTROLS (CENTERLINE) (AFF, AFG, UNLESS NOTED OTHERWISE) 48" 48" ANNOTATION �}1 MECHANICAL PLAN CALLOUT MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER SECTION CUT DESIGNATION 10 "0 CSD -1 300 10 "0 CSD -1 300 MECHANICAL PLAN SCALE: 1/4" =1 '-0" SERVICE � \ � \, o \ `\ Li PLAN NOTES: 10"s6 CSD -1 300 EXTEND VERTICAL SUPPLY AND RETURN DUCTS FULL SIZE OF UNIT. CONNECT TO HORIZONTAL DUCTWORK IN CEILNG PLENUM. PROVIDE CANVAS CONNECTIONS AT UNIT. REFER TO SPECIFICATIONS. O CONTRACTOR SHALL PROVIDE LOCKING THERMOSTAT COVER, ✓ EXTEND REFRIGERANT PIPING FROM CRU -1 THRU ROOF TO CU -1. SIZE PER MANUFACTURER'S REQUIREMENTS. REFER TO SPECIFICATIONS. 4O EXISTING ROOFTOP UNIT. VEFIRY UNIT IS IN GOOD WORKING ORDER AND REPORT ANY DEFICIENCIES TO ARCHITECT. 0 0 \ 10 "0 CSD -1 300 ■ MECHANICAL GENERAL NOTES: 1O "0 CSD -1 300 0 " " 300 0 1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND ALL OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS, WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT, ENGINEER AND /OR VERIZON OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 3. MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. 4. THERMOSTATS SHALL BE LOCATED AND SET BY MECHANICAL CONTRACTOR AND WIRED IN CONDUIT BY ELECTRICAL CONTRACTOR. THERMOSTATS SHALL BE LABELED WITH ASSOCIATED HVAC UNIT. MOUNTING HEIGHTS SHALL BE 48" AFF TO MEET ADA REQUIREMENTS UNLESS NOTED OTHERWISE ON PLANS. 5. STRUCTURAL ENGINEERING, BRACING, FRAMES, AND ROOF PENETRATIONS MUST BE DONE BY LANDLORD APPROVED ROOFING CONTRACTOR AT CONTRACTOR'S EXPENSE TO MAINTAIN ROOF WARRANTY AND AS REQUIRED BY CITY BUILDING INSPECTOR. 6. SYSTEM SHALL BE BALANCED BY NEBB CERTIFIED PERSONNEL. SUBMIT T &B REPORT TO ENGINEER FOR REVIEW. 7. DO NOT ROUTE DUCTWORK DIRECTLY ABOVE ELECTRICAL PANELS OR EQUIPMENT. 8. CONTRACTOR SHALL FIELD VERIFY THAT THE EXISTING EQUIPMENT INCLUDING ACCESSORIES IS NOT DAMAGED AND IS IN GOOD WORKING ORDER. REPORT ANY DEFICIENCIES TO THE OWNER AND /OR ARCHITECT. I i,-. Qi V f CODE C C MPL T �s . .,e 'O` " OCT 2 5 2107 City y �g g Of EXPIRED AUG 0 5 2008 G7, 15 YOI F !'iIVIE 1 GL'tV I ER PROJ. DRWN. DATE 2007 -0174 EC 9 -25 -07 l 18 OF 27 18x18 10 "0 CSD -1 300 10x 10 10 "0 CSD -1 250 10X10 _1_8x1_Q ..._ 10 "0 CSD-1 250 10x10 10 "4 CSD -1 250 22x12 TECH 8" 0 CSD -1 150 18x12 50 _1 ilk?, 8 "CA • CSD -2 \ 50 .8x8 CEO - [LC H LSKOM 10 JANIT fR CL. 22x22 CRG -1 OCRU -1 RTU -2 TELCO 105 l CUSTOVER SERVICE 1.1 10 "0 CSD -1 300 10"0 CSD -1 300 10 "0 CSD -1 300 O r co x co N 22x22 ,CRG -1 — 'L (TYP 2) - a x 0 COPVFAX r 1 1 MI 11114, 28x12 10"0 CSD -1 300 10 "0 CS� f_ — ( A i f0- ES i jr ____ 11 1 1 t � f ____1.-1------ = Y t i` 1 1 _r t 1 t RETAIL SALES 0 10 "0 CSD -1 300 -T tix 11 ~ (©► nEr ‘; CA 10x12 -s- t--- — • 10"O CSD -1 300 10x12 MECHANICAL SYMBOLS I NOTE NECESSARILY USED ON LEGEND THE AND DRAWINGS. ALL SYMBOLS, ETC. ARE PIPING CD ACD RL RD RS HWS — — HWR — — CWS — —CWR— — HS -- -HR LPS —LPC- 14-4 — ti 4.1 ---zl 9 I � to CONDENSATE DRAIN (CD) AUXILIARY CONDENSATE DRAIN (ACD) REFRIGERANT LIQUID (RL) REFRIGERANT DISCHARGE (HOT GAS) (RD) REFRIGERANT SUCTION (RS) HEATING HOT WATER SUPPLY (HWS) HEATING HOT WATER RETURN (HWR) CHILLED WATER SUPPLY (CWS) CHILLED WATER RETURN (CWR) HEAT PUMP SUPPLY (HS) HEAT PUMP RETURN (HR) LOW PRESSURE STEAM SUPPLY (LPS) LOW PRESSURE STEAM CONDENSATE (LPC) EXISTING PIPING TO BE REMOVED EXISTING PIPING TO REMAIN DIRECTION OF FLOW BALL VALVE CONTROL VALVE THREE —WAY CONTROL VALVE SHUTOFF VALVE CHECK VALVE BALANCING VALVE WITH PRESSURE PORTS TRIPLE DUTY VALVE WITH PRESSURE PORTS WATER METER STRAINER SOLENOID VALVE PRESSURE GAUGE THERMOMETER UNION FLANGE CONNECTION ELBOW UP ELBOW DOWN TEE UP TEE DOWN HVAC EQUIPMENT & DUCTWORK NOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. SEE SECTION 15250 OF THE SPECIFICATION FOR DUCTWORK TO RECEIVE INSULATION OR LINER. Jr L FD FIRE DAMPER FIRE SMOKE DAMPER SMOKE DAMPER VOLUME DAMPER MOTORIZED DAMPER BACKDRAFT DAMPER EXISTING DUCTWORK OR EQUIPMENT TO REMAIN EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED BRANCH DUCT WITH 45' RECTANGLE —ROUND BRANCH FITTING AND MANUAL VOLUME DAMPER ELBOW WITH TURNING VANES RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN SUPPLY AIR DUCT UP SUPPLY AIR DUCT DOWN EQUIPMENT WITH FLEXIBLE DUCT CONNECTION 10" CSD -1 300 CFM NECK SIZE, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER MANUAL VOLUME DAMPER SQUARE TO ROUND TRANSITION DUCT MOUNTED• SMOKE ' DETEGTDR (5D ..SU w�'LY� /. RD RELUF2N� CO2 HS CARBON DIOXIDE SENSOR HUMIDITY SENSOR PS PULL STATION IsPj STATIC PRESSURE SENSOR TEMPERATURE SENSOR JTS� 0 HUMIDISTAT O THERMOSTAT ABBREVIATIONS AFF BAS BD CFM Doc DX EA FFA FFB GPM IN WC MAX MBH ABOVE FINISHED FLOOR BUILDING AUTOMATION SYSTEM BACKDRAFT DAMPER CUBIC FEET PER MINUTE DIRECT DIGITAL CONTROL DIRECT EXPANSION EXHAUST AIR FROM FLOOR ABOVE FROM FLOOR BELOW GALLONS PER MINUTE INCHES OF WATER COLUMN MAXIMUM 1000 BTU PER HOUR MC MIN NC OA RA SA SD TFA TFB TYP UNO W/ W/O MECHANICAL CONTRACTOR MINIMUM NOISE CRITERIA OUTSIDE AIR RETURN AIR SUPPLY AIR SMOKE DUCT DETECTOR TO FLOOR ABOVE TO FLOOR BELOW TYPICAL UNLESS NOTED OTHERWISE WITH WITHOUT STANDARD MOUNTING HEIGHTS MECHANICAL THERMOSTATS (USER ADJUSTABLE) CONTROLS (CENTERLINE) (AFF, AFG, UNLESS NOTED OTHERWISE) 48" 48" ANNOTATION �}1 MECHANICAL PLAN CALLOUT MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER SECTION CUT DESIGNATION 10 "0 CSD -1 300 10 "0 CSD -1 300 MECHANICAL PLAN SCALE: 1/4" =1 '-0" SERVICE � \ � \, o \ `\ Li PLAN NOTES: 10"s6 CSD -1 300 EXTEND VERTICAL SUPPLY AND RETURN DUCTS FULL SIZE OF UNIT. CONNECT TO HORIZONTAL DUCTWORK IN CEILNG PLENUM. PROVIDE CANVAS CONNECTIONS AT UNIT. REFER TO SPECIFICATIONS. O CONTRACTOR SHALL PROVIDE LOCKING THERMOSTAT COVER, ✓ EXTEND REFRIGERANT PIPING FROM CRU -1 THRU ROOF TO CU -1. SIZE PER MANUFACTURER'S REQUIREMENTS. REFER TO SPECIFICATIONS. 4O EXISTING ROOFTOP UNIT. VEFIRY UNIT IS IN GOOD WORKING ORDER AND REPORT ANY DEFICIENCIES TO ARCHITECT. 0 0 \ 10 "0 CSD -1 300 ■ MECHANICAL GENERAL NOTES: 1O "0 CSD -1 300 0 " " 300 0 1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND ALL OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS, WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT, ENGINEER AND /OR VERIZON OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 3. MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. 4. THERMOSTATS SHALL BE LOCATED AND SET BY MECHANICAL CONTRACTOR AND WIRED IN CONDUIT BY ELECTRICAL CONTRACTOR. THERMOSTATS SHALL BE LABELED WITH ASSOCIATED HVAC UNIT. MOUNTING HEIGHTS SHALL BE 48" AFF TO MEET ADA REQUIREMENTS UNLESS NOTED OTHERWISE ON PLANS. 5. STRUCTURAL ENGINEERING, BRACING, FRAMES, AND ROOF PENETRATIONS MUST BE DONE BY LANDLORD APPROVED ROOFING CONTRACTOR AT CONTRACTOR'S EXPENSE TO MAINTAIN ROOF WARRANTY AND AS REQUIRED BY CITY BUILDING INSPECTOR. 6. SYSTEM SHALL BE BALANCED BY NEBB CERTIFIED PERSONNEL. SUBMIT T &B REPORT TO ENGINEER FOR REVIEW. 7. DO NOT ROUTE DUCTWORK DIRECTLY ABOVE ELECTRICAL PANELS OR EQUIPMENT. 8. CONTRACTOR SHALL FIELD VERIFY THAT THE EXISTING EQUIPMENT INCLUDING ACCESSORIES IS NOT DAMAGED AND IS IN GOOD WORKING ORDER. REPORT ANY DEFICIENCIES TO THE OWNER AND /OR ARCHITECT. I i,-. Qi V f CODE C C MPL T �s . .,e 'O` " OCT 2 5 2107 City y �g g Of EXPIRED AUG 0 5 2008 G7, 15 YOI F !'iIVIE 1 GL'tV I ER EXISTING - ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK e MODEL TONS SUPPLY FAN COOLING COIL HEATING COIL MIN. MCA MOCP V /PH DISC. NOTES AMB CF) 100 V /PH 208/1 MCA / MOC 11/15 CRU- 1 /CU -1 FAN CFM ESP MIN TH SH EAT LAT EER MIN. OUTPUT EFF. MIN. NO. 0/A TOTAL = 836 TOTAL = 950 TYPE E Q 03 D 00 TYPE (IN) HP (MBH) (MBH) (DB /WB) (DB /WB) (MIN) (MBH) ( %) ■ i CFM RTU -1 YORK DF090 P ROJ. 2007 -0174 2,650 DRWN. EC 67 DATE 9 -25 -07 56/54 10.3 96 80 2 2 59.3 19 OF 27 208/3 NF EXISTING - ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK MANUFACTURER MODEL TONS SUPPLY FAN COOLING COIL HEATING COIL MIN. MCA MOCP V /PH DISC. NOTES AMB CF) 100 V /PH 208/1 MCA / MOC 11/15 CRU- 1 /CU -1 FAN CFM ESP MIN TH SH EAT LAT EER MIN. OUTPUT EFF. MIN. NO. 0/A TOTAL = 836 TOTAL = 950 TYPE TYPE (IN) HP (MBH) (MBH) (DB /WB) (DB /WB) (MIN) (MBH) ( %) STAGES CFM RTU -1 YORK DF090 7.5 FC 2,650 1.0 67 63 78/63 56/54 10.3 96 80 2 550 59.3 70 208/3 NF A —D RTU -2 YORK DF078 6.5 FC 2,500 1.0 61 58 77/62 56/54 10.3 96 80 2 400 56.6 60 208/3 NF A —D NOTES: A. EXISTING UNIT TO REMAIN. VERIZON CONTRACTOR SHALL PROVIDE ALTERNATE BID TO REPLACE UNIT IF EXISTING UNIT DOES NOT HAVE AN ECONOMIZER AND BAROMETRIC RELIEF. B. PROVIDE 2 ", 30% EFFICIENT PLEATED THROWAWAY AIR FILTERS. SIZE AND QUANTITY SHALL MATCH EXISTING. C. PROVIDE 7—DAY PROGRAMMABLE THERMOSTAT WITH STAGED HEATING AND COOLING CAPABILITY AS REQUIRED FOR OPERATION OF HEATING, COOLING AND ECObbIO CO�T ,OLS. PROVIDE ACRYLIC, VANDAL —PROOF LO HER MOSTAT COVER. DIMS ON X1 : 2ACTQR % TO URN SH AND -(NSTA TWO E, ,DETECTORS IK,, SUPPL :'A AND RETURN AIR DUCTS -NONE TS COMPUTER ROOM UNIT SCHEDULE MARK MANUFACTURER MODEL EVAPORATOR SECTION CONDENSING SECTION NOTES A —D CFM TC (MBH) EAT (DB /WB) V /PH MCA / MOCP FLA AMB CF) 100 V /PH 208/1 MCA / MOC 11/15 CRU- 1 /CU -1 MITSUBISHI PK12 /PU12 450 12.5 75/62 208/1 1/15 1 NOTES: A. CONTRACTOR SHALL VERIFY WITH EQUIPMENT SUPPLIER EXACT ROUTING AND SIZE OF INSULATED REFRIGERANT PIPING. INSTALL PER MANUFACTURERS RECOMMENDATIONS. B. DIVISION 16 CONTRACTOR TO PROVIDE DISCONNECT SWITCH FOR EVAPORATOR SECTION AND CONDENSING SECTION. C. PROVIDE WITH WALL MOUNTED THERMOSTAT BY UNIT MANUFACTURER. D. PROVIDE WITH INTEGRAL CONDENSATE PUMP. GRILLE, REGISTER AND DIFFUSER SCHEDULE MARK MANUFACTURER MODEL TYPE MOUNTING FACE SIZE (IN) NOTES CSD -1 CARNES SPAB SUPPLY LAY IN 24x24 A —F CRG -1 CARNES SPJB RETURN LAY IN 24x24 A,C —F CEG -1 CARNES SPJB EXHAUST LAY IN 12x12 A,C —F NOTES: A. NECK SIZE SHOWN ON DRAWINGS. B. 4 —WAY THROW PATTERN UNLESS OTHERWISE SHOWN ON DRAWINGS. C. BRANCH DUCT SIZE SHALL BE SAME AS NECK SIZE UNLESS OTHERWISE SHOWN ON DRAWINGS. D. BAKED ENAMEL FINISH, PAINTED TO MATCH CEILING COLOR. E. FRAME TYPE TO MATCH CEILING CONSTRUCTION, COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN. F. PROVIDE BORDER TYPE TO MATCH CEILING CONSTRUCTION. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN. FAN SCHEDULE. MARK SERVICE _( EA, RA, SAL EA MANUFACTURER COOK MOUNTING ROOF MODEL 60 ACEB CFM 200 ESP (IN) 0.5 DRIVE (BELT /DIRECT) BELT HP 0.25 FAN RPM 1847 ELECTRICAL NOTES A —C V /PH 120/1 DISC. TYPE NF EF -1 NOTES: A. PROVIDE WITH MINIMUM 12" HIGH ROOF CURB, BIRDSCREEN AND BACKDRAFT DAMPER. B. PROVIDE WITH INTEGRAL DISCONNECT SWITCH. C. DIVISION 16 CONTRACTOR TO FURNISH CONTROL RELAY AS REQUIRED TO INTERLOCK FAN WITH LIGHT SWITCHES. OUTSIDE AIR REQUIREMENTS AREA PURPOSE GROSS FLOOR AREA (SQ. FT) ASHRAE 62 -1999 OUTSIDE AIR REQUIREMENTS SYSTEM NUMBER ACTUAL OUTSIDE AIR (CFM PER UNIT) CFM PER SQ. FT CFM REQD. RTU -1 550 RTU -2 400 SALES 2,365 0.30 710 NON SALES 845 0.15 127 TOTAL = 836 TOTAL = 950 MITSUBISHI CONDENSING UNIT RETURN AIR DUCT FOIL TAPE AT INSULATION JOINT PRE — INSULATED FLEXIBLE DUCT AS REQUIRED, INSTALL PERMANENTLY SEALED AND SUPPORTED TO PREVENT KINKING AND SHARP TURNS METAL BAND (TYPICAL) CEILING DIFFUSER WITH VOLUME DAMPER, FIRE DAMPER OR COMBINATION VOLUME /FIRE DAMPER AS SCHEDULED NOTES: ROOFTOP HVAC UNIT (BY LANDLORD) REFRIGERANT PIPING SUPPLY AIR DUCT CANVAS CONNECTION (TYPICAL) NOTES I. PROVIDE OPENING THROUGH ROOF AND ROOF DECK INSULATION NO LARGER THAN REQUIRED TO ALLOW DUCTS TO PASS THROUGH. REFER TO PLANS FOR DUCT SIZES. TRANSITION AS REQUIRED IN ROOF CURB TO RTU SUPPLY AND RETURN OPENINGS. ROOFTOP UNIT WITH DUCTWORK DETAIL NO SCALE NOTES: INSTALL THE MITSUBISHI CONDENSING UNIT SERVING THE ELEC /TECH CLOSET ON THE FLAT ROOF. INSTALL UNIT ON PRE CAST CONCRETE PAVERS ON TOP OF RUBBER CUSHION MATTING. THE PAVERS SHOULD BE COORDINATED WITH THE CONDENSING UNIT IN SIZE (APPROXIMATE 3" THICK x 4' LONG x 8" WIDE). USING TAPCON TYPE ANCHORS, ATTACH UNIT TO PAVERS. PROVIDE NEMA 3R DISCONNECT SWITCH. EXTEND REFRIGERANT PIPING AND LIQUIDTIGHT CONDUIT THROUGH ROOF IN FLASHED ROOF OPENING THROUGH SIDE (NO VERTICAL OPENINGS IN THE ROOF OR TAR PITCH POCKETS) THYCURB TP -2 OR APPROVED EQUAL. COMPUTER ROOM CONDENSING UNIT INSTALLATION DETAIL NO SCALE METAL BAND OVER INSULATION (TYPICAL) HIGH EFFICIENCY TAKEOFF EXTERNALLY INSULATED, WITH VOLUME DAMPER AND DAMPER LOCK WITH EXTENSION CEILING 1 I - - np MODI;OdAilM• F =43 INSULATED DUCT 1. EXTEND RIGID METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT EXCEED 5' -0 ". PROVIDE RIGID 90' ELBOW WHERE REQUIRED TO KEEP FLEXIBLE DUCT WITHIN 5' -0" LENGTH LIMITATION. 2. PROVIDE RIGID ROUND —TO —OVAL TRANSITION WHEN PLENUM HAS OVAL CONNECTION. LAY -IN AND SLOT TYPE CEILING DIFFUSER DETAIL NO SCALE EXTEND DUCTWORK OVER TOP OF CURB, SECURE DUCTWORK TO CURB NAILER SECURE CURB TO ROOF WITH SCREWS, PINS, OR BOLTS FASTEN ANGLE IRON SECURELY TO DUCT AND ROOF STRUCTURE PIPING, DUCTWORK, CEILING SUPPORTS ETC. NOT ALLOWED IN THIS 2' SPACE TO ALLOW FOR MAINTENANCE. EXTERNAL INSULATION IF NOT INTERNALLY LINED DAMPER CONCENTRIC SHEETMETAL REDUCER, WHEN REQUIRED BY DUCT SIZE METAL FLEXIBLE CONNECTION MAXIMUM 6" BY ATCO MODEL UPC #018. OVERLAP DUCT WRAP INSULATION AND SEAL SQUARE TO ROUND TAKE —OFF FITTING r L SUPPLY DUCT EXHAUST FAN WITH BIRDSCREEN SECURE EXHAUST FAN TO ROOF CURB ROOF DECK REFER TO ARCHITECTURAL DRAWINGS ` COUNTER BALANCED BACKDRAFT (UNLESS NOTED OTHERWISE) DAMPER, SECURE TO DUCT FROM ABOVE TO ALLOW SERVICE OR REMOVAL OF DAMPER FROM ROOF EXHAUST DUCT UP THROUGH ROOF. SEE PLANS FOR SIZE AND LOCATION. DOWNBLAST EXHAUST FAN DETAIL (BY LANDLORD) NO SCALE PREFABRICATED INSULATED CURB WITH TREATED WOOD NAILER. \ROOF INSULATION �iI1FJ(;;� Ala - L SUPPLY DUCT ALLOW FOR REQUIRED NEC CLEARANCE ELECTRIC HEATING COIL AND CONTROL ENCLOSURE r ACTUATOR I— PIPING DUCTWORK, CEILING SUPPORTS ETC. NOT ALLOWED IN THIS 2' SPACE TO ALLOW FOR MAINTENANCE. CONTROLLER I BOX FLOW METERING STATION MINIMUM 3X DUCT DIAMETER INSULATION AS REQUIRED (EXTERNAL SHOWN) NOTES: 1. SUPPORT AIR TERMINAL UNIT, BOTH ENDS WITH MINIMUM 2" WIDE GALVANIZED 22 GA. HANGER STRAPS. 2. INSTALL BOX NOT MORE THAN 3 FEET ABOVE THE CEILING TO ENABLE ACCESS FOR MAINTENANCE. VARIABLE AIR VOLUME BOX WITH ELECTRIC REHEAT COIL DETAIL NO SCALE VARIABLE AIR VOLUME TERMINAL SCHEDULE (ELECTRIC HEAT) MARK VAV -1 NOTES: UNIT SERVED RTU -2 MANUFACTURER TITUS MODEL AESV INLET SIZE (IN) 12 MINIMUM CFM MIN HEAT. CFM PRIMARY CFM 1300 650 650 HEATING COIL EAT 55 MBH 28.2 KW 8 STEPS 2 SOUND V /PH RADIATED 208/3 A. HEATING COIL CAPACITY BASED ON 40 'F MAX. AIR TEMPERATURE RISE, 95 'F MAX. DISCHARGE AIR TEMPERATURE, AND 450 FPM MINIMUM COIL FACE VELOCITY. B. INSTALL FLEXIBLE DUCT CONNECTOR AT INLET CONNECTION. C. PROVIDE INTEGRAL DISCONNECT SWITCH. D. PROVIDE FACTORY INSTALLED CONTROL POWER TRANSFORMER. E. BOX NOT TO EXCEED SCHEDULED DISCHARGE OR RADIATED NOISE DB USING 0.5" W.G. INLET PRESSURE IN THE 3RD OCTAVE BAND. F. PROVIDE TEMPERATURE SENSOR IN VAV BOX WITH HTG /CLG AUTOCHANGEOVER. G. PROVIDE FACTORY— INSTALLED, PRESSURE INDEPENDENT, ELECTRONIC CONTROL PACKAGE. 52 DISCHARGE 61 NOTES A —G %'' e `a APPRO L � 1N — Oty Of "Tlik(V43 \ EX s' AUG 0 5 2008 D PEEC=EI ` ITS' . I' , C^ . 's,,J jk piL,114I1 I CEA I hR 1 2 ESS E SUITE 116 3 20 OF 27 15k HEATING. VENTILATING, ANp AIR CONDITIONING 15A 1 GENERAL INSTRUCTIONS 15A 1 -1 GENERAL REQUIREMENTS REQUIREMENTS UNDER DMSION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. CONTRACTOR SHALL BECOME THOROUGHLY ACQUAINTED WITH ITS CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION INCLUDES MATERIAL, EQUIPMENT, APPLIANCES, TRANSPORTATION, SERVICES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. 15A 1 -2 DEFINITIONS FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS 'TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITEM WILL BE FURNISHED BY THE OWNER OR OTHERS. IT IS TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDENTAL TO THE WORK, INCLUDING SERVICES NECESSARY FOR PROPER INSTALLATION AND OPERATION. THE INSTALLATION SHALL BE INCLUDED UNDER THE GUARANTEE REQUIRED BY THIS DMSION. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DMSION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT ". AHJ: THE LOCAL CODE AND /OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. THE TERMS "APPROVED EQUAL ", "EQUIVALENT ", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 15A 1 -3 PREBID SITE VISIT PRIOR TO SUBMITTING BID, VISIT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 15A 1 -4 MATERIAL AND WORKMANSHIP PROVIDE NEW MATERIAL, EQUIPMENT, AND APPARATUS UNDER THIS CONTRACT UNLESS OTHERWISE STATED HEREIN, OF BEST QUALITY NORMALLY USED FOR THE PURPOSE IN GOOD COMMERCIAL PRACTICE. AND FREE FROM DEFECTS. MODEL NUMBERS LISTED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT NECESSARILY INTENDED TO DESIGNATE THE REQUIRED TRIM, WRITTEN DESCRIPTIONS OF THE TRIM GOVERN MODEL NUMBERS. PIPE, PIPE FITTINGS, PIPE SPECIALTIES AND VALVES SHALL BE MANUFACTURED IN PLANTS LOCATED IN THE UNITED STATES. WORK PERFORMED UNDER THIS CONTRACT SHALL PROVIDE A NEAT AND "WORKMANLIKE" APPEARANCE WHEN COMPLETED, TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER. WORKMANSHIP SHALL BE THE FINEST POSSIBLE BY EXPERIENCED MECHANICS. INSTALLATIONS SHALL COMPLY WITH APPLICABLE CODES AND LAWS. THE COMPLETE INSTALLATION SHALL FUNCTION AS DESIGNED AND INTENDED WITH RESPECT TO EFFICIENCY, CAPACITY, NOISE LEVEL, ETC. ABNORMAL NOISE CAUSED BY RATTLING EQUIPMENT, PIPING, DUCTS, AIR DEVICES, AND SQUEAKS IN ROTATING COMPONENTS WILL NOT BE ACCEPTABLE. IN GENERAL, MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTED. REMOVE FROM THE PREMISES WASTE MATERIAL PRESENT AS A RESULT OF WORK, INCLUDING CARTONS, CRATING, PAPER, STICKERS, AND /OR EXCAVATION MATERIAL NOT USED IN BACKFILLING, ETC. CLEAN EQUIPMENT INSTALLED UNDER THIS CONTRACT TO PRESENT A NEAT AND CLEAN INSTALLATION AT THE TERMINATION OF THE WORK. REPAIR OR REPLACE PUBLIC AND PRIVATE PROPERTY DAMAGED AS A RESULT OF WORK PERFORMED UNDER THIS CONTRACT TO THE SATISFACTION OF AUTHORITIES AND REGULATIONS HAVING JURISDICTION. 15A 1 -5 COORDINATION COORDINATE WORK WITH THAT OF OTHER TRADES SO THAT THE VARIOUS COMPONENTS OF THE SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, AND WILL ALLOW PROPER SERVICE ACCESS TO THOSE ITEMS REQUIRING MAINTENANCE. COMPONENTS WHICH ARE INSTALLED WITHOUT REGARD TO THE ABOVE SHALL BE RELOCATED AT NO ADDITIONAL COST TO THE OWNER. UNLESS OTHERWISE INDICATED, THE GENERAL CONTRACTOR WILL PROVIDE CHASES AND OPENINGS IN BUILDING CONSTRUCTION REQUIRED FOR INSTALLATION OF THE SYSTEMS SPECIFIED HEREIN. CONTRACTOR SHALL FURNISH THE GENERAL CONTRACTOR WITH INFORMATION WHERE CHASES AND OPENINGS ARE REQUIRED. KEEP INFORMED AS TO THE WORK OF OTHER TRADES ENGAGED IN THE CONSTRUCTION OF THE PROJECT, AND EXECUTE WORK IN A MANNER AS TO NOT INTERFERE WITH OR DELAY THE WORK OF OTHER TRADES. FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALE DIMENSIONS. CONTRACTOR SHALL TAKE HIS OWN MEASUREMENTS AT THE BUILDING, AS VARIATIONS MAY OCCUR. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION. PROVIDE MATERIALS WITH TRIM THAT WILL PROPERLY FIT THE TYPES OF CEILING, WAIL, OR FLOOR FINISHES ACTUALLY INSTALLED. MODEL NUMBERS USTED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT INTENDED TO DESIGNATE THE REQUIRED TRIM. 15A 1 -6 ORDINANCES AND CODES WORK PERFORMED UNDER THIS CONTRACT SHALL, AT A MINIMUM, BE IN CONFORMANCE WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES HAVING JURISDICTION. EQUIPMENT FURNISHED AND ASSOCIATED INSTALLATION WORK PERFORMED UNDER THIS CONTRACT SHALL BE IN STRICT COMPLIANCE WITH CURRENT APPLICABLE CODES ADOPTED BY THE LOCAL AHJ INCLUDING ANY AMENDMENTS AND STANDARDS AS SET FORTH BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NEPA), UNDERWRITERS LABORATORIES (UL), OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME), AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS ( ASHRAE), AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) AND OTHER NATIONAL STANDARDS AND CODES WHERE APPLICABLE. WHERE THE CONTRACT DOCUMENTS EXCEED THE REQUIREMENTS OF THE REFERENCED CODES, STANDARDS, ETC., THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE. PROCURE AND PAY FOR PERMITS AND LICENSES REQUIRED FOR THE ACCOMPLISHMENT OF THE WORK HEREIN DESCRIBED. WHERE REQUIRED, OBTAIN, PAY FOR AND FURNISH CERTIFICATES OF INSPECTION TO OWNER. CONTRACTOR WILL BE HELD RESPONSIBLE FOR VIOLATIONS OF THE LAW. 15A 1 -7 PROTECTION OF EQUIPMENT AND MATERIALS STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO JOB SITE. COVER WITH WATERPROOF, TEAR- RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC AS REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION ACTIVITIES WILL BE REJECTED, AND CONTRACTOR IS OBLIGATED TO FURNISH NEW EQUIPMENT AND MATERIAL OF A LIKE KIND. KEEP PREMISES BROOM CLEAN FROM FOREIGN MATERIAL CREATED DURING WORK PERFORMED UNDER THIS CONTRACT. PIPING, EQUIPMENT, ETC. SHALL HAVE A NEAT AND CLEAN APPEARANCE AT THE TERMINATION OF THE WORK. PLUG OR CAP OPEN ENDS OF DUCTWORK AND PIPING SYSTEMS WHILE STORED AND INSTALLED DURING CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF DEBRIS INTO THE SYSTEMS. 15A 1 -8 SUBSTITUTIONS THE BASE BID SHALL INCLUDE ONLY THE PRODUCTS FROM MANUFACTURERS SPECIFICALLY NAMED IN THE DRAWINGS AND SPECIFICATIONS. NO SUBSTITUTION WILL BE CONSIDERED PRIOR TO RECEIPT OF BIDS UNLESS WRITTEN REQUEST FOR APPROVAL TO BID HAS BEEN RECEIVED BY THE ARCHITECT AT LEAST TEN CALENDAR DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS. EACH SUCH REQUEST SHALL INCLUDE THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT IS TO BE SUBSTITUTED AND A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE INCLUDING DRAWINGS, CUTS, PERFORMANCE AND TEST DATA AND OTHER INFORMATION NECESSARY FOR AN EVALUATION. A STATEMENT SETTING FORTH CHANGES IN OTHER MATERIALS, EQUIPMENT OR OTHER WORK THAT INCORPORATION OF THE SUBSTITUTE WOULD REQUIRE SHALL BE INCLUDED. THE BURDEN OF PROOF OF THE MERIT OF THE PROPOSED SUBSTITUTE IS UPON THE PROPOSER. THE ENGINEER'S DECISION OF APPROVAL OR DISAPPROVAL TO BID OF A PROPOSED SUBSTITUTION SHALL BE FINAL. THE TERMS "APPROVED ", "APPROVED EQUAL ", OR "EQUAL ", REFER TO APPROVAL BY THE ENGINEER AS AN ACCEPTABLE ALTERNATE BID. NO SUBSTITUTIONS WILL BE CONSIDERED THAT ARE NOT BID AS AN ALTERNATE. NO MATERIAL SUBSTITUTIONS SHALL BE CONSIDERED FOR APPROVAL PRIOR TO AWARD OF CONTRACT. COORDINATE AND VERIFY WITH OTHER TRADES WHETHER OR NOT THE SUBSTITUTED EQUIPMENT CAN BE INSTALLED AS SHOWN ON THE CONSTRUCTION DRAWINGS WITHOUT MODIFICATION TO ASSOCIATED SYSTEMS OR ARCHITECTURAL OR ENGINEERING DESIGN. INCLUDE ADDMONAL COSTS FOR ARCHITECTURAL AND ENGINEERING DESIGN FEES IN BID IF DRAWING MODIFICATIONS ARE REQUIRED BECAUSE OF SUBSTITUTED EQUIPMENT. 15A 1 -9 SPARE PARTS FURNISH TO OWNER, WITH RECEIPT, THE FOLLOWING SPARE PARTS FOR THE EQUIPMENT FURNISHED FOR THIS PROJECT: A. ONE SET OF SPARE FILTERS OF EACH TYPE REQUIRED FOR EACH UNIT. IN ADDITION TO THE SPARE SET OF FILTERS, INSTALL NEW FILTERS PRIOR TO TESTING, ADJUSTING, AND BALANCING WORK AND BEFORE TURNING SYSTEM OVER TO OWNER. B. FURNISH ONE COMPLETE SET OF BELTS FOR EACH FAN. C. FURNISH THREE OPERATING KEYS FOR EACH TYPE OF AIR OUTLET AND INLET THAT REQUIRE THEM. 15A 1 -10 WARRANTIES WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DIVISION 1. WARRANTIES SHALL INCLUDE LABOR AND MATERIAL MAKE REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER OR OWNER. AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM UNITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. 15A 1 -11 CUTTING AND PATCHING PERFORM CUTTING OF WALLS, FLOORS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK UNDER THIS SECTION. OBTAIN PERMISSION FROM THE ARCHITECT PRIOR TO CUTTING. DO NOT CUT OR DISTURB STRUCTURAL MEMBERS WITHOUT PRIOR APPROVAL FROM THE ARCHITECT. CUT HOLES AS SMALL AS POSSIBLE. GENERAL CONTRACTOR SHALL PATCH WALLS, FLOORS, ETC. AS REQUIRED BY WORK UNDER THIS SECTION. PATCHING SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION. REPAIR AND REFINISH AREAS DISTURBED BY WORK TO THE CONDITION OF ADJOINING SURFACES IN A MANNER SATISFACTORY TO THE ARCHITECT. 15A 1 -12 ROUGH -IN COORDINATE WITHOUT DELAY ROUGHING -IN WITH GENERAL CONSTRUCTION. CONCEAL PIPING AND CONDUIT ROUGH -IN EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE SHOWN. 15A 1 -13 CONCRETE BASES PROVIDE CONCRETE BASES FOR EQUIPMENT WHERE INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN. CONCRETE BASES SHALL HAVE CHAMFERED EDGES. SIZE OF PAD SHALL BE A MINIMUM OF 4" GREATER THAN THE FOOTPRINT OF THE EQUIPMENT THAT IT IS SUPPORTING AND SHALL HAVE A MINIMUM HEIGHT OF 3 -1/2 ". CONSTRUCT EQUIPMENT BASES AND HOUSEKEEPING PADS OF A MINIMUM 28 DAY, 4000 PSI CONCRETE CONFORMING TO AMERICAN CONCRETE INSTITUTE STANDARD BUILDING CODE FOR REINFORCED CONCRETE (ACT 318 -99) AND THE LATEST APPLICABLE RECOMMENDATIONS OF THE ACI STANDARD PRACTICE MANUAL. CONCRETE SHALL BE COMPOSED OF CEMENT CONFORMING TO ASTM C 150 TYPE I, AGGREGATE CONFORMING TO ASTM C33, AND POTABLE WATER. EXPOSED EXTERIOR CONCRETE SHALL CONTAIN 5 TO 7 PERCENT AIR ENTRA LAMENT. UNLESS OTHERWISE SPECIFIED OR SHOWN ON THE STRUCTURAL DRAWINGS, REINFORCE EQUIPMENT BASES AND HOUSEKEEPING PADS WITH NO. 4 REINFORCING BARS CONFORMING TO ASTM A 615 OR 6X6 - W2.9 X W2.9 WELDED WIRE MESH CONFORMING TO ASTM A185. PLACE REINFORCING BARS 24" ON CENTER WITH A MINIMUM OF TWO BARS EACH DIRECTION PROVIDE GALVANIZED ANCHOR BOLTS FOR EQUIPMENT PLACED ON CONCRETE EQUIPMENT BASES AND HOUSEKEEPING PADS OR ON CONCRETE SLABS. ANCHOR BOLTS SIZE, NUMBER AND ;'LACEMENT SHALL BE AS RECOMMENDED BY THE MANUFACTURER OF THE EQUIPMENT. 15A i -14 STRUCTURAL STEEL STRUCTURAL STEEL USED FOR SUPPORT OF EQUIPMENT, DUCTWORK AND PIPING SHALL BE NEW, CLEAN, AND CONFORM TO ASTM DESIGNATION A -36. SUPPORT MECHANICAL COMPONENTS FROM THE BUILDING STRUCTURE. DO NOT SUPPORT MECHANICAL COMPONENTS FROM CEILINGS, OTHER MECHANICAL OR ELECTRICAL COMPONENTS, AND OTHER NON- STRUCTURAL ELEMENTS. 15A 1 -15 ACCESS DOORS PROVIDE ACCESS DOORS IN CEILINGS, WALLS, ETC. WHERE INDICATED OR REQUIRED FOR ACCESS OR MAINTENANCE TO CONCEALED VALVES AND EQUIPMENT INSTALLED UNDER THIS SECTION. PROVIDE CONCEALED HINGES, SCREWDRIVER -TYPE LOCK, ANCHOR STRAPS; MANUFACTURED BY MILCOR, ZURN, TITUS, OR EQUAL. OBTAIN ARCHITECT'S APPROVAL OF TYPE, SIZE, LOCATION AND COLOR BEFORE ORDERING. 15A 1-16 PENETRATIONS SEAL MECHANICAL FLOOR, EXTERIOR WALL AND ROOF RENEIRATIONS WATERTIGHT AND WEATHERTIGHT. SEAL AROUND MECHANICAL PENEIRATIONS WITH 3M CP -25 FIRE BARRIER CAULK (THICKNESS AS REQUIRED AND RECOMMENDED BY MANUFACTURER) TO MAINTAIN FIRE RESISTANCE RATING OF FIRE -RATED ASSEMBLIES. PROVIDE PREFABRICATED ROOF CURBS MANUFACTURED BY CUSTOM CURB, INC., PATE COMPANY, THYCURB OR APPROVED EQUAL PROVIDE ROOF CURB WITH FACTORY INSTALLED WOOD NAILER; WELDED, 18 GAUGE GALVANIZED STEEL SHELL, BASE PLATE AND FLASHING; 1- 1/2" THICK, 3 POUND RIGID INSULATION; FULLY MITERED 3 -INCH RAISED CANT; COVER OF WEATHER-RESISTANT, WEATHER-PROOF MATERIAL AND PIPE COLLAR OF WEATHER - RESISTANT MATERIAL WITH STAINLESS STEEL PIPE CLAMPS. 15A 1 -17 AIR FILTERS PROVIDE FARR 30/30 PLEATED, THROWAWAY TYPE FILTERS, UNLESS OTHERWISE INDICATED. AIR UNITS SHALL HAVE NEW FILTERS INSTALLED WHEN THEY ARE OPERATED BEFORE FINAL ACCEPTANCE. FILTERS SHALL BE MANUFACTURED BY AMERICAN AIR FILTER, FARR, FLANDERS, OR APPROVED EQUAL. IF HVAC EQUIPMENT IS USED DURING THE CONSTRUCTION PERIOD, CONTRACTOR SHALL PROVIDE ONE SET OF FILTERS WHEN THE UNIT IS STARTED AND REPLACE FILTERS WHEN NEEDED, BUT NOT LESS THAN EVERY MONTH. ON THE DAY OF SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL CLEAN THE UNIT AND PROVIDE A NEW SET OF FILTERS IN THE UNIT. 15A 1 -18 MOTORS AND STARTERS PROVIDE MOTORS AND STARTING EQUIPMENT WHERE NOT FURNISHED WITH THE EQUIPMENT PACKAGE. MOTORS SHALL HAVE COPPER WINDINGS, CLASS B INSULATION, AND STANDARD SQUIRREL CAGE WITH STARTING TORQUE CHARACTERISTICS SUITABLE FOR THE EQUIPMENT SERVED. MOTORS FOR AIR HANDLING EQUIPMENT SHALL BE SELECTED FOR QUIET OPERATION. EACH MOTOR SHALL BE CHECKED FOR PROPER ROTATION AFTER ELECTRICAL CONNECTION HAS BEEN COMPLETED. PROVIDE DRIPPROOF ENCLOSURE FOR LOCATIONS PROTECTED FROM WEATHER AND NOT IN AIR STREAM OF FAN; AND TOTALLY ENCLOSED FAN COOLED ENCLOSURE FOR MOTORS EXPOSED TO WEATHER. MOTORS SHALL BE MANUFACTURED BY CENTURY, GENERAL ELECTRIC, WESTINGHOUSE, LOUIS ALLIS, OR APPROVED EQUAL. PROVIDE EVERY MOTOR, EXCEPT FRACTIONAL HORSEPOWER SINGLE PHASE MOTORS WITH OF "BUILT -IN" THERMAL AN APPROVED TYPE O OVERLOAD PROTECTION, WITH A MOTOR STARTER. EACH STARTER SHALL BE PROVIDED WITH OVERLOAD HEATERS SIZED TO THE MOTOR RATING, AND EVERY THREE PHASE MOTOR STARTER SHALL HAVE OVERLOAD HEATERS IN EACH PHASE. AMBIENT COMPENSATED HEATERS SHALL BE INSTALLED WHEREVER NECESSARY. UNLESS NOTED OTHERWISE, MOTOR STARTERS SHALL BE FURNISHED BY THE DIVISION 15 CONTRACTOR FOR INSTALLATION AND CONNECTION BY THE DIVISION 16 CONTRACTOR. STARTERS SHALL BE ALLEN - BRADLEY, CLARK, FURNAS, SQUARE D, OR APPROVED EQUAL. 15A 1 -19 ELECTRICAL WIRING LINE VOLTAGE WIRING SHALL BE PROVIDED BY DIVISION 16. LINE VOLTAGE CONTROL AND INTERLOCK WIRING FOR MECHANICAL SYSTEMS SHALL ALSO BE PROVIDED BY DIVISION 16 CONTRACTOR. LOW VOLTAGE CONTROL WIRING SHALL BE PROVIDED BY THE DIVISION 16 CONTRACTOR. FURNISH WIRING DIAGRAMS TO THE DIVISION 16 CONTRACTOR AS REQUIRED FOR PROPER EQUIPMENT HOOKUP. COORDINATE WITH THE DIVISION 16 CONTRACTOR THE ACTUAL WIRE SIZING AMPS FOR MECHANICAL EQUIPMENT (FROM THE EQUIPMENT NAMEPLATE) TO ENSURE PROPER INSTALLATION. 15A 1 -20 REFRIGERANT AND OIL PROVIDE FULL REFRIGERANT AND OIL CHARGE IN NEW AIR CONDITIONING REFRIGERATION SYSTEMS, AND MAINTAIN IT FOR FULL TERM OF THE GUARANTEE. CONTRACTOR TO VERIFY ADEQUATE CHARGE IN ALL EXISTING AIR CONDITIONING REFRIGERATION SYSTEMS AND ADD REFRIGERANT AS NECESSARY. 15A 1 -21 FINAL TESTING AND ADJUSTMENTS FINAL SYSTEM TESTING, BALANCING AND ADJUSTMENTS SHALL BE PERFORMED BY A CONTRACTOR CERTIFIED BY THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) OR OTHER APPROVED AGENCY. PERFORM TEST READINGS ON FANS, UNITS, COILS, ETC. AND ADJUST EQUIPMENT TO DELIVER SPECIFIED AMOUNTS OF AIR. PREPARE TESTING AND BALANCING REPORT LOG SHOWING AIR SUPPLY QUANTITIES, AIR ENTERING AND LEAVING TEMPERATURES AND PRESSURES, FAN AND UNIT TEST READINGS, ETC., AND SUBMIT SIX COPIES OF THE FINAL COMPILATION OF DATA TO THE ARCHITECT FOR EVALUATION AND APPROVAL BEFORE FINAL INSPECTION OF THE PROJECT. BALANCE AIR SYSTEMS TO WITHIN PLUS OR MINUS 10 PERCENT FOR TERMINAL DEVICES AND BRANCH LINES AND PLUS OR MINUS 5 PERCENT FOR MAIN DUCTS AND AIR HANDLING EQUIPMENT OF THE AMOUNT OF AIR SHOWN ON THE DRAWINGS. FURTHER ADJUSTMENTS SHALL BE MADE TO OBTAIN UNIFORM TEMPERATURE IN SPACES. ADJUST EQUIPMENT TO OPERATE AS INTENDED BY THE SPECIFICATION. ALIGN BEARINGS AND REPLACE BEARINGS THAT HAVE DIRT OR FOREIGN MATERIAL IN THEM WITH NEW BEARINGS WITHOUT ADDITIONAL COST TO THE OWNER. BALANCE CONTRACTOR SHALL INCLUDE IN THE REPORT ANY IMPROPERLY INSTALLED OR MISSING BALANCING DEVICES THAT WOULD NEGATIVELY IMPACT THE SYSTEM OPERATION. ADJUST THERMOSTATS AND CONTROL DEVICES TO OPERATE AS INTENDED. ADJUST FANS, ETC. FOR PROPER AND EFFICIENT OPERATION. CERTIFY TO ARCHITECT THAT ADJUSTMENTS HAVE BEEN MADE AND THAT SYSTEM IS OPERATING SATISFACTORILY. FURTHER ADJUSTMENTS SHALL BE MADE TO OBTAIN UNIFORM TEMPERATURE IN SPACES. CALIBRATE, SET, AND ADJUST AUTOMATIC TEMPERATURE CONTROLS. CHECK PROPER SEQUENCING OF INTERLOCK SYSTEMS, AND OPERATION OF SAFETY CONTROLS. 15A 1-22 EQUIPMENT FURNISHED BY OTHERS PROVIDE NECESSARY EQUIPMENT AND ACCESSORIES THAT ARE NOT PROVIDED BY THE EQUIPMENT SUPPLIER OR OWNER TO COMPLETE INSTALLATION OF COOKING EQUIPMENT, WASHING EQUIPMENT, ETC., FURNISHED BY OTHERS, IN LOCATIONS AS INDICATED ON THE DRAWINGS AND /OR DESCRIBED IN THE GENERAL NOTES TO THIS CONTRACTOR. EQUIPMENT AND ACCESSORIES NOT PROVIDED BY THE EQUIPMENT SUPPLIER MAY INCLUDE FLUES, VENTS, INTAKES, ASSOCIATED ROOF JACKS AND CAPS TO OUTDOORS, DAMPERS, IN -LINE FANS, ROOF FANS, CONTROL INTERLOCKS, ETC. AS REQUIRED FOR PROPER OPERATION OF THE COMPLETE SYSTEM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECT ROUGH -IN DIMENSIONS, AND SHALL VERIFY SAME WITH ARCHITECT AND /OR EQUIPMENT SUPPLIER PRIOR TO SERVICE INSTALLATIONS. 15A 1 -23 MISCELLANEOUS REMODELING WORK REMOVE ALL UNUSED EQUIPMENT, DUCTWORK, PIPING AND ASSOCIATED SUPPORTS. CAP DUCTWORK AND PIPING AT MAINS AND SEAL AIR AND WATER TIGHT. PROVIDE ITEMS OF HVAC SYSTEMS MODIFICATION REQUIRED BECAUSE OF BUILDING REMODELING, AS NOTED ON THE DRAWINGS OR NECESSARY FOR PROPER OPERATION. MATCH EXISTING MATERIALS AND CONSTRUCTION TECHNIQUES WHEN MODIFYING EXISTING SYSTEMS UNLESS SPECIFIED OTHERWISE. COORDINATE ADDITIONAL REQUIREMENTS WITH GENERAL CONTRACTOR AND ARCHITECT. SEAL AIRTIGHT EXISTING DUCTWORK REQUIRED TO BE ABANDONED IN PLACE OR NOT IN USE AT THE TERMINATION OF THE WORK. CAP AND SEAL WEATHERTIGHT EXISTING ROOF CURBS AND ROOF OPENINGS TO BE ABANDONED IN PLACE AS A RESULT OF EQUIPMENT REMOVAL. CLEAN AND REBALANCE EXISTING DUCTWORK, DIFFUSERS, REGISTERS, AND GRILLES INTENDED FOR REUSE AS REQUIRED OR AS INDICATED ON DRAWINGS. CLEAN AND REFURBISH EXISTING HVAC EQUIPMENT INTENDED FOR REUSE AS REQUIRED FOR PROPER OPERATION INCLUDING REPLACEMENT OF FILTERS, BELTS, MOTORS, REMOTE CONTROLS, AND SAFETY INTERLOCKS. 15A 1 -25 SEISMIC PROTECTION FOR MECHANICAL & ELECTRICAL 15A 1 -25A GENERAL REQUIREMENTS THE REQUIREMENTS FOR SEISMIC PROTECTION MEASURES TO BE APPLIED TO MECHANICAL /ELECTRICAL EQUIPMENT AND SYSTEMS SPECIFIED HEREIN ARE IN ADDITION TO ANY OTHER ITEMS CALLED FOR IN OTHER SECTIONS OF THESE SPECIFICATIONS. ALL ANCHOR CONNECTIONS TO STRUCTURE FOR SUPPORT OF MECHANICAL /ELECTRICAL EQUIPMENT, REGARDLESS OF THE NEED FOR SEISMIC RESTRAINTS, SHALL BE SHOWN ON SHOP DRAWINGS AND SUBMITTED FOR APPROVAL BY THE ENGINEER OF RECORD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE TYPE AND LOCATION OF SEISMIC SUPPORTS REQUIRED FOR THE MECHANICAL AND ELECTRICAL ELEMENTS SHOWN ON THE CONTRACT DRAWINGS BASED vN THE SEISMIC ZONE. THE SIZE AND WEIGHT OF THE SUPPORTED ELEMENT AND THE DISTANCE FROM STRUCTURE THAT THE ELEMENT WILL BE INSTALLED. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING THE TYPES AND LOCATIONS OF REQUIRED SEISMIC SUPPORTS. ALL SEISMIC RESTRAINTS, ISOLATORS, AND ISOLATION MATERIALS SHALL BE OF THE SAME MANUFACTURER AND SHALL BE CERTIFIED BY THE MANUFACTURER. SEISMIC PROTECTION SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND /OR FEDERAL CODES. INSTALLATION SHALL ALSO BE IN STRICT ACCORDANCE WITH COMPONENT MANUFACTURER'S REQUIREMENTS AND STANDARDS AND WITH INDUSTRY CONSTRUCTION STANDARDS. WHENEVER CONFLICTS OCCUR BETWEEN CODES OR STANDARDS, THE MOST STRINGENT SHALL APPLY. 15A 2 INSULATION AND SHEET METAL WORK 15A 2 -1 DUCT INSULATION PROVIDE DUCT LINER ONLY IN EXPOSED RECTANGULAR SUPPLY AND RETURN AIR DUCTWORK. LINER SHALL BE 1 -1/2" THICK (MIN R -5), 3 POUND DENSITY FIBERGLASS, CERTAINTEED CORP. "TOUGHGARD" OR OWENS - CORNING "AEROFLEX DUCT UNER. LINER SURFACE SHALL SERVE AS A BARRIER AGAINST INFILTRATION OF DUST AND DIRT, SHALL MEET ASTM C 665 FOR FUNGI RESISTANCE AND SHALL BE CLEANABLE USING DUCT CLEANING METHODS AND EQUIPMENT OUTLINED BY NORTH AMERICAN INSULATION MANUFACTURERS ASSOCIATION (NAIMA) DUCT CLEANING GUIDE. INSTALL WITH MASTIC AND MECHANICAL FASTENERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS AND SMACNA "DUCT LINER APPLICATION STANDARD ". DUCTWORK SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. SHEET METAL MUST BE INCREASED BY UNER THICKNESS IN BOTH DIRECTIONS WHERE LINER IS INSTALLED. SEE DRAWINGS FOR LOCATION, THICKNESSES, ETC. ALL SUPPLY, RETURN, AND OUTSIDE AIR DUCTWORK INSTALLED ABOVE A CEILING SHALL BE COVERED WITH 2" THICK (MIN R -5) DUCT WRAP, CERTAINTEED OR EQUAL OWENS- CORNING, 3/4 POUND DENSITY, WITH HEAVY -DUTY FOIL- SCRIM -KRAFT FACING, AND WITH JOINTS TAPED WITH 3" WIDE FOIL TAPE. INSULATING MATERIALS, ADHESIVES, COATINGS, ETC., SHALL NOT EXCEED FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATING OF 50 PER ASTM E 84. CONTAINERS FOR MASTICS AND ADHESIVES SHALL HAVE U.L. LABEL. 15A 2 -2 DUCTWORK PROVIDE GALVANIZED STEEL DUCTWORK AND HOUSINGS AS SHOWN ON DRAWINGS. CONSTRUCT DUCTWORK INCLUDING FIIIINGS AND TRANSITIONS IN CONFORMANCE WITH CURRENT SMACNA STANDARDS RELATIVE TO GAUGE, BRACING, JOINTS, ETC. MINIMUM THICKNESS OF DUCT SHALL BE 26 GAUGE SHEET METAL REINFORCE HOUSINGS AND DUCTWORK OVER 30" WITH 1 -1/4" ANGLES NOT LESS THAN 5' -6" ON CENTERS, AND CLOSER IF REQUIRED FOR SUFFICIENT RIGIDITY TO PREVENT VIBRATION. SUPPORT HORIZONTAL RUNS OF DUCT FROM STRAP IRON HANGERS ON CENTERS NOT TO EXCEED 8' -0 ". DO NOT SUPPORT CEILING GRID, CONDUITS, PIPES, EQUIPMENT, ETC. FROM DUCTWORK. CONSTRUCT SUPPLY DUCTS TO MEET SMACNA POSITIVE PRESSURE OF 2" W.G. CONSTRUCT RETURN, OUTDOOR AND EXHAUST DUCTWORK UPSTREAM OF FANS TO MEET SMACNA NEGATIVE PRESSURE OF 1" W.G. CONSTRUCT EXHAUST DUCTWORK DOWNSTREAM OF FANS TO MEET SMACNA POSITIVE PRESSURE OF 1" W.G. EXPOSED DUCTWORK TO BE FIELD PAINTED SHALL HAVE GALVANIZED METAL PRIMER APPLIED IN THE SHOP AFTER FABRICATION AND PRIOR TO SHIPPING. SEAL DUCTWORK WITH HEAVY LIQUID SEALANT, HARDCAST IRONGRIP 601, DESIGN POLYMER DP 1010 , UNITED MCGILL DUCT SEALER OR APPROVED EQUAL, APPLIED ACCORDING TO SEALANT MANUFACTURER'S INSTRUCTIONS. FOR DUCTS WITH PRESSURE CLASSIFICATION OF 2" W.G. SEAL LONGITUDINAL AND TRANSVERSE DUCTWORK JOINTS AIRTIGHT TO MEET SMACNA CLASS B. FOR DUCTS WITH PRESSURE CLASSIFICATION LESS THAN 2" W.G. SEAL TRANSVERSE JOINTS AIRTIGHT TO MEET SMACNA CLASS C. PROVIDE AIRFOIL TYPE TURNING VANES, OF SAME GAUGE AS DUCTWORK, RIGIDLY FASTENED WITH GUIDE STRIPS IN DUCTWORK HAVING AN OFFSET OF 45 DEGREES OR MORE. CONNECT FANS, BLOWERS, UNITS, ETC. TO DUCTWORK WITH NEOPRENE COATED GLASS CLOTH CANVAS CONNECTIONS, DURO -DYNE, ELGEN, VENTFABRIC OR EQUAL. CANVAS CONNECTIONS SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED RATING NOT HIGHER THAN 50. INSTALL WITH MINIMUM 1 -1/2" SLACK. PROVIDE BALANCING DAMPERS, MANUFACTURED BY RUSKIN, GREENHECK, NAILOR INDUSTRIES, CESCO, LOUVERS & DAMPERS, POTTORFF OR APPROVED EQUAL. WHERE SHOWN ON DRAWINGS AND WHEREVER NECESSARY FOR COMPLETE CONTROL OF AIR FLOW. SPLIIIER DAMPERS SHALL BE CONTROLLED BY LOCKING QUADRANTS; PROVIDE YOUNG REGULATOR OR VENTLOK END BEARINGS FOR THE DAMPER ROD. RECTANGULAR VOLUME DAMPERS SHALL BE OPPOSED BLADE INTERLOCKING TYPE. ROUND VOLUME DAMPERS SHALL BE BUTTERFLY TYPE CONSISTING OF CIRCULAR BLADE MOUNTED TO A SHAFT. DAMPER LEAKAGE FOR OUTSIDE AIR DAMPERS SHALL NOT EXCEED 6.5 CFM /SQUARE FOOT IN FULL CLOSED POSITION AT 4" WG PRESSURE DIFFERENTIAL ACROSS DAMPER. REFERENCE MANUFACTURER AND MODEL NUMBER FOR OUTSIDE AIR DAMPERS IS RUSKIN MODEL CD -50. FLEXMASTER MODEL STO OR EQUAL 45 DEGREE RECTANGULAR /ROUND SIDE TAKEOFF FITTING WITH MODEL SLBO DOUBLE BEARING DAMPER WITH INSULATION BUILD OUT FOR ROUND DUCTWORK BRANCH TAKEOFFS TO INDIVIDUAL AIR DEVICES. WHERE ACCESS TO DAMPERS THROUGH A HARD CEILING IS REQUIRED, PROVIDE A METROPOLITAN AIR TECHNOLOGY OR YOUNG'S REGULATOR CONCEALED, CABLE OPERATED VOLUME DAMPER WITH REMOTE OPERATOR. DAMPER SHALL BE ADJUSTABLE THROUGH THE DIFFUSER FACE OR FRAME WITH STANDARD 1/4" NUTDRIVER OR FLAT SCREWDRIVER. CABLE ASSEMBLY SHALL ATTACH TO DAMPER AS ONE PIECE WITH NO LINKAGE ADJUSTMENT. POSITIVE, DIRECT, TWO -WAY DAMPER CONTROL SHALL BE PROVIDED WITH NO SLEEVES, SPRINGS OR SCREW ADJUSTMENTS TO COME LOOSE AFTER INSTALLATION. SUPPORT CABLE ASSEMBLY TO AVOID BENDS AND KINKS IN CABLE. ROUND OR OVAL DUCTWORK SHALL BE SEMCO, UNITED, WESCO OR EQUAL, SHEETMETAL, WITH SMOOTH INTERIOR SURFACE, WITH LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) ROUND DUCTWORK GAUGES PER THE FOLLOWING TABLE (REFERENCE SMACNA HVAC DUCT CONSTRUCTION STANDARDS FOR GAUGES WHEN PRESSURES EXCEED 2" W.G.): UNDAB SPIROSAFE, LEWIS & LAMBERT OR APPROVED EQUAL FACTORY- MANUFACTURED ROUND DUCTWORK AND FITTINGS MAY BE SUBSTITUTED FOR SPECIFIED ROUND BRANCH DUCTWORK, AT CONTRACTORS OPTION. HEAVY LIQUID JOINT SEALANT MAY BE OMITTED ON FACTORY - MANUFACTURED ROUND DUCTWORK. LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) FITTINGS 24" IN DIAMETER AND LESS SHALL BE PREFABRICATED, SPOTWELDED AND INTERNALLY SEALED. CONTINUOUSLY WELD FITTINGS LARGER THAN 24" IN DIAMETER. FITTING GAUGE SHALL BE 22 GAUGE FOR 36" FITTINGS AND UNDER, 20 GAUGE FOR LARGER SIZES. 90 DEGREE TEE'S SHALL BE CONICAL TYPE. SEAL LONGITUDINAL AND TRANSVERSE DUCTWORK JOINTS AIRTIGHT WITH HEAVY LIQUID SEALANT APPLIED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 15A 2-3 FLEXIBLE DUCT LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) AND MEDIUM PRESSURE (DUCT PRESSURE CLASS 2.1" TO 6" W.G.) FLEXIBLE DUCT SHALL BE FLEXMASTER TYPE 8, THERMAFLEX TYPE G -KM, OR EQUAL (FIRE RETARDANT POLYETHYLENE) PROTECTIVE VAPOR BARRIER, U.L.181 CLASS 1, ACOUSTICAL INSULATED DUCT, 2" (R -6.0) FIBERGLASS INSULATION. PROVIDE CPE LINER WITH STEEL WIRE HELIX MECHANICALLY LOCKED OR PERMANENTLY BONDED TO THE LINER. FLEXIBLE DUCT RUNS SHALL NOT EXCEED 5 FEET IN LENGTH, AND SHALL BE INSTALLED STRAIGHT AS POSSIBLE AVOIDING TIGHT TURNS. CONNECT EACH END WITH STAINLESS STEEL SCREW OPERATED METAL DRAWBANDS. 15A 2 -4 AIR DEVICES PROVIDE AIR DEVICES AS SCHEDULED ON DRAWINGS, MANUFACTURED BY CARNES, E.H. PRICE, KRUEGER, NAILOR INDUSTRIES, TITUS, OR TUTTLE & BAILEY. SELECT AIR DEVICES TO UMIT ROOM NOISE LEVEL TO NO HIGHER THAN NC -30 UNLESS OTHERWISE SHOWN. PROVIDE DEVICES WITH A SOFT PLASTIC GASKET TO MAKE AN AIRTIGHT SEAL AGAINST THE MOUNTING SURFACE. COORDINATE FINAL LOCATION, FRAME, AND MOUNTING TYPE OF AIR DEVICES WITH ARCHITECTURAL REFLECTED CEILING PLANS. 15A 2 -5 PLENUMS CONSTRUCT PLENUMS WITH GALVANIZED STEEL FRAMING MEMBERS AND GALVANIZED SHEETMETAL, BRACED WITH GALVANIZED ANGLES. GAUGES AND BRACING SHALL CONFORM TO SMACNA RECOMMENDATIONS FOR DUCTWORK OF UKE SIZES. WHERE ACCESS DOORS ARE SHOWN, PROVIDE HINGED DOORS WITH #202 VENTLOK LATCH. MAKE WATERTIGHT CONNECTIONS TO LOUVERS, SLOPING BOTTOM OF PLENUM TO DRAIN WATER TO WEEPHOLES IN BOTTOM OF LOUVER. 15A 2 -6 EXHAUST /VENTILATION AIR SYSTEMS PROVIDE ROOF MOUNTED EXHAUST FANS AS SCHEDULED ON THE DRAWINGS, OR EQUAL COOK, GREENHECK, CARNES, JENCO FANS, ACME OR PENN BARRY COMPLETE WITH ALUMINUM HOUSING, ALUMINUM CENTRIFUGAL WHEEL, MOTOR WITH INTEGRAL THERMAL OVERLOAD PROTECTION, DISCONNECT SWITCH MOUNTED INSIDE THE HOUSING, BIRDSCREEN, BACKDRAFT DAMPER, AND PATE PREFABRICATED ROOF CURB. 15A 3 HVAC EQUIPMENT 15A 3 -1 ROOFTOP UNITS (GAS FIRED HEAT) REUSE EXISTING ROOFTOP UNIT. COORDINATE REQUIREMENTS WITH MANUFACTURER. CLEAN UNIT AND PROVIDE NEW FILTERS PRIOR TO START UP. DIVISION 16 CONTRACTOR SHALL PROVIDE A UL USTED DUCT TYPE SMOKE DETECTOR IN SUPPLY AIR AND RETURN AIR DUCTWORK AS REQUIRED BY CODE TO SHUT DOWN ROOFTOP UNIT UPON DETECTION OF SMOKE. 15A 3 -2 VAV BOXES SIZE GAUGE 14" & UNDER 26 PROVIDE TITUS, E.H. PRICE, CARNES, KREUGER OR ENVIRONMENTAL TECHNOLOGIES SINGLE DUCT, VARIABLE AIR VOLUME TERMINAL OF SIZES AND CAPACITIES SHOWN ON DRAWINGS. CONSTRUCT THE CASING OF 22 GAUGE MINIMUM SHEET METAL AND LINED WITH STERI -LOC NON - POROUS LINER WITH 3.5 R VALUE INSULATION THAT MEETS UL 181, NFPA 90A, AND ASTM C665. FULLY COVER EDGES OF INSULATION WITH METAL COVER STRIPS. REMOVABLE ACCESS PANELS WITH AIRTIGHT GASKETS AND QUARTER -TURN LATCHES SHALL BE PROVIDED FOR ACCESS TO INTERNAL BOX COMPONENTS REQUIRING SERVICE. CONSTRUCT THE DAMPER BLADE OF HEAVY GAUGE STEEL WITH SHAFT ROTATING IN DELRIN OR BRONZE OILITE SELF- LUBRICATING BEARINGS. DAMPER BLADES SHALL SEAT AGAINST GASKETED STOPS TO LIMIT LEAKAGE IN FULL CLOSED POSITION TO 10 PERCENT OF RATED AIRFLOW WHEN SUBJECTED TO 6" STATIC PRESSURE. PROVIDE PRESSURE INDEPENDENT CONTROLS ACCURATE TO 1.5 DEGREES F AND ADJUSTABLE FROM 65 TO 85 DEGREES F. FACTORY INSTALL ANALOG ELECTRONIC CONTROLS FOR THE CONTROL SEQUENCE SPECIFIED IN THE SCHEDULE. AIR FLOW SENSORS SHALL BE CROSS CONFIGURATION WITH A MINIMUM OF 12 PICK -UP POINTS. PROVIDE TEMPERATURE SENSOR IN BOX INLET TO ENABLE AUTOMATIC CHANGEOVER OF BOX OPERATION BASED ON HEATING AND COOLING MODE OF PRIMARY UNIT. PROVIDE ELECTRIC RESISTANCE HEATING COILS OF OPEN COIL CONSTRUCTION WITH 80 PERCENT NICKEL, 20 PERCENT CHROMIUM. PROVIDE NEMA 1 CONTROL PANEL, ALUMINIZED OR GALVANIZED STEEL FRAME, AIRFLOW SWITCH, THERMAL OVERLOAD PROTECTION AND MERCURY CONTACTORS. THE STATIC PRESSURE DROP SHALL NOT EXCEED 0.2" WG AT THE SCHEDULED MAXIMUM AIR FLOW AND THE NOISE CRITERIA DISCHARGE SHALL NOT EXCEED 30 AT A DIFFERENTIAL STATIC PRESSURE OF 0.15" INCLUDING ROOM AND CEILING EFFECTS. 15A 3 -3 COMPUTER ROOM UNITS PROVIDE SPLIT SYSTEM CONSISTING OF EVAPORATOR SECTION FOR WALL MOUNTING AND REMOTE CONDENSING SECTION SIMILAR TO MITSUBISHI, COMPU -AIRE, OR DATA AIRE. EVAPORATOR CABINET SHALL BE FACTORY ASSEMBLED PRE -WIRED CONSISTING OF FURNITURE -GRADE STEEL WITH BAKED- ENAMEL FINISH, FRONT ACCESS, WITH DIRECT -DRIVE CENTRIFUGAL FANS, 2 -SPEED MOTOR, AND CLEANABLE FOAM FILTER. EVAPORATOR COIL SHALL BE DIRECT - EXPANSION COOLING COIL OF SEAMLESS COPPER TUBES EXPANDED INTO ALUMINUM FINS, WITH THERMAL - EXPANSION VALVE WITH EXTERNAL EQUALIZER. AIR - COOLED CONDENSER SHALL BE OF CORROSION - RESISTANT CABINET CONTAINING COMPRESSOR, COPPER -TUBE ALUMINUM -FIN COILS, DIRECT -DRIVE PROPELLER FANS WITH MOTORS WITH INTERNAL OVERLOAD PROTECTION; CAPACITY CONTROL TO 0 DEG F. FILTER: 1-INCH- (25 -MM -) THICK, DISPOSABLE, GLASS -FIBER MEDIA. FILTER SHALL HAVE A MINIMUM MERV RATING PER ASHRAE 52.2 OF MERV 5. PROVIDE REFRIGERANT PIPING SIZED AS RECOMMENDED BY EQUIPMENT MANUFACTURER WITH 3/4" THICK FOAMED PLASTIC INSULATION ON THE SUCTION LINE. CONTROL SYSTEM: UNIT- MOUNTED PANEL WITH CONTACTORS, CONTROL TRANSFORMER WITH CIRCUIT BREAKER, SOLID -STATE TEMPERATURE CONTROL MODULES. PROVIDE SOLID - STATE, UNIT - MOUNTED CONTROL PANEL WITH START -STOP SWITCH, ADJUSTABLE TEMPERATURE SET POINT, AND REMOTE WALL - MOUNTED THERMOSTAT. REFER TO SEQUENCE OF OPERATION. 15A 4 TEMPERATURE CONTROLS 15A 4 -1 GENERAL REQUIREMENTS CONTRACTOR SHALL PROVIDE SUPERVISION AND ON -JOB CHECKOUT SERVICE AS REQUIRED TO ENSURE THAT INSTALLATION MEETS REQUIREMENTS OF THE SPECIFICATION. THE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FOLLOWING THE ACCEPTANCE OF THE SYSTEM BY THE ARCHITECT /ENGINEER. CORRECT DEFECTS OCCURRING DURING THIS PERIOD AT NO ADDITIONAL COST TO THE OWNER. 15A 4 -2 EQUIPMENT MANUFACTURERS AND MODEL NUMBERS ARE USTED FOR REFERENCE AS TO QUALITY AND FEATURES REQUIRED FOR THE CONTROL DEVICES. PROVIDE CONTROL DEVICES BY BARBER - COLMAN, HONEYWELL, JOHNSON CONTROLS, TRANE OR WHITE RODGERS WITH QUALITY AND FEATURES AS INDICATED. SEVEN DAY PROGRAMMABLE, OCCUPIED /UNOCCUPIED THERMOSTATS FOR CONTROL OF MULTIPLE STAGES OR MODULATION OF HEATING AND COOLING SYSTEMS AND FOR CONTROL OF ECONOMIZER SYSTEM SHALL BE HONEYWELL SERIES 7350 THERMOSTAT WITH INTEGRAL SUBBASE AND W7215A ECONOMIZER MODULE. THERMOSTATS SHALL BE SEVEN DAY PROGRAMMABLE WITH LARGE BACKLIT TOUCH SCREEN, AUTO OR MANUAL CHANGE OVER AND EASY TO USE MENU DRIVEN PROGRAMMING. THERMOSTAT SHALL HAVE MULTIPLE HOLD OPTIONS FOR PROGRAM OVERRIDE WITH THE ABILITY TO PROGRAM SERVICE REMINDERS FOR AIR FILTERS. THERMOSTATS SHALL HAVE AN ELECTRICAL RATING OF 20 TO 30 VAC, A TEMPERATURE RANGE OF 40 F TO 90 F (HEAT): 50 F to 99 F (COOL) AND A ONE DEGREE DIFFERENTIAL. INSTALL THERMOSTATS AT 48" AFF TO MEET ADA REQUIREMENTS UNLESS OTHERWISE NOTED ON THE PLANS. DIMENSIONS SHALL BE 6" W X 4 -9/16" H X 1 -1/14" D. 15A 5 SEQUENCE OF OPERATION 15A 5 -1 ROOFTOP UNIT CONTROL OCCUPIED MODE OPERATE ROOFTOP UNIT SUPPLY FAN CONTINUOUSLY WITH OUTSIDE AIR DAMPER OPEN TO MAINTAIN MINIMUM VENTILATION. CYCLE STAGE(S) OF COOLING AND HEATING TO MAINTAIN ROOM THERMOSTAT SETPOINT (75 DEGREES FAHRENHEIT ADJUSTABLE). MODULATE OUTDOOR AIR ECONOMIZER TO MAINTAIN 55 DEGREES FAHRENHEIT SUPPLY AIR TEMPERATURE WHEN AMBIENT TEMPERATURE REACHES 60 DEGREES FAHRENHEIT (ADJUSTABLE) OR BELOW. RETURN ECONOMIZER TO MINIMUM POSITION WHEN AMBIENT TEMPERATURE IS ABOVE 60 DEGREES FAHRENHEIT. SUPPLY AIR AND RETURN AIR DUCT MOUNTED SMOKE DETECTORS SHALL SHUTDOWN UNIT UPON ALARM. SETBACK MODE ROOFTOP UNIT SHALL CYCLE TO MAINTAIN 65 DEGREES - WINTER (ADJ) AND 80 DEGREES - SUMMER (ADJ) WHILE THE OUTSIDE AIR DAMPER IS FULLY CLOSED AND THE RETURN AIR DAMPER IS FULL OPEN. 15A5 -2 RESTROOM EXHAUST FAN CONTROL EXHAUST FAN SHALL BE INTERLOCKED WITH RESPECTIVE RESTROOM LIGHT SWITCHES AND BE ENERGIZED THRU A RELAY CONTROL WHEN LIGHT SWITCH IS 'ON' AND DE- ENERGIZED WHEN LIGHT SWITCH IS 'OFF'. 15A5 -3 VAV BOX CONTROL UPON A RISE IN SPACE TEMPERATURE ABOVE COOLING SETPOINT THE TERMINAL UNIT PRIMARY DAMPER SHALL MODULATE TOWARDS ITS MAXIMUM COOLING CFM. A DROP IN SPACE TEMPERATURE SHALL RESULT IN THE UNIT PRIMARY DAMPER MODULATING TOWARDS ITS MINIMUM COOLING CFM. AS THE SPACE TEMPERATURE CONTINUES TO FALL, THE UNIT SHALL MODULATE ITS PRIMARY COOLING FLOW TO ITS MINIMUM CFM AND ENERGIZE THE HEAT AS FOLLOWS: WITH THE PRIMARY DAMPER IN MINIMUM POSITION AND WHEN THE ROOM TEMPERATURE FALLS BELOW SETPOINT, CYCLE STAGES OF HEATING COIL TO MAINTAIN ROOM SETPOINT TEMPERATURE. HEATING /COOLING AUTOCHANGEOVER SHALL SEQUENCE TERMINAL UNIT WHEN RTU IS IN HEATING MODE AS FOLLOWS: WHEN SUPPLY TEMPERATURE IS BELOW 70 DEG THE UNIT SHALL OPERATE IN THE COOLING MODE. AN INCREASE IN SPACE TEMPERATURE SHALL CAUSE PRIMARY DAMPER TO MODULATE TOWARDS ITS MAXIMUM COOLING CFM. UPON A RISE IN SUPPLY TEMPERATURE ABOVE 75 DEG UNIT SHALL CHANGE TO HEATING MODE AND MODULATE PRIMARY DAMPER TO MINIMUM POSITION. A DECREASE IN ROOM TEMPERATURE SHALL CAUSE PRIMARY DAMPER TO MODULATE OPEN. IF SUPPLY TEMPERATURE DECREASES BELOW 70 DEG UNIT SHALL CHANGE BACK TO COOLING MODE. DURING UNOCCUPIED MODE, THE UNIT SHALL SEQUENCE THE SAME AS THE OCCUPIED CYCLE TO MAINTAIN A REDUCED SETBACK SPACE TEMPERATURE. 15A5 -4 COMPUTER ROOM UNIT CONTROL OPERATE COMPUTER ROOM UNIT CONTINUOUSLY. CYCLE STAGE(S) OF COOLING TO MAINTAIN ROOM TEMPERATURE SETPOINT (75 DEGREES FAHRENHEIT ADJUSTABLE). ott x D1OR CODE COMPLIANCE APPROVED OC. 2 5 200 BUILDING w illa City O Tuk EXPI ED AUG 0 5 Z008 GIN u, 3 2�,ii7 LCal 1 (JLN I LA n�� _\ n-cr —N zc A ,-1.4-! .�...�,