HomeMy WebLinkAboutPermit M07-223 - BOEING #11-14NfJ ZZ - LOW ZIT S Z6Z M17T-TT# oiaoa Parcel No.: 0923049155 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 2925 S 112 ST TUKW Citf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us BOEING #11 -14N 2925 S 112 ST , TUKWILA WA BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 Contact Person: Name: JOE CEDERNA Address: 9410 DELRIDGE WY SW , SEATTLE WA MECHANICAL PERMIT Contractor: Name: SYSTEM HEATING & AIR CONDITIONING CO INC Address: 9410 DELRIDGE WY SW , SEATTLE WA Contractor License No: SYSTEHA19OBT Value of Mechanical: 161,665.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 10/02/2008 DESCRIPTION OF WORK: LIKE FOR LIKE REPLACEMENT OF ROOF PENTHOUSE MOUNTED COOLING TOWER PER PROJECT 556- 553 -01 SPECIFICATIONS. (SEE EXPIRED PERMIT M07 -043.) M07 -223 02/05/2008 08/03/2008 Phone: Phone: 206 762 -4249 X 109 Phone: 206 -762 -4249 Fees Collected: $1,555.23 International Mechanical Code Edition: 2006 Boiler Compressor: 0 - 3 HP /100,000 BTU 0 3 - 15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 5 M07 -223 Printed: 02 -05 -2008 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe grmance of wor . auth• ' ed to sign and obtain this mechanical permit. Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us LL),,ILAJ la Permit Number: MOT-223 Issue Date: 02/05/2008 Permit Expires On: 08/03/2008 Date: Date: a /67J This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -223 Printed: 02 -05 -2008 Parcel No.: 0923049155 Address: 2925 S 112 ST TUKW Suite No: Tenant: BOEING #11 -14N 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 - 223 Status: ISSUED Applied Date: 10/19/2007 Issue Date: 02/05/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 431 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 15: Sprinlders shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) doc: Cond -10/06 M07 -223 Printed: 02 -05 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 17: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 18: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 19: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 20: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 21: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 23: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doe: Cond -10/06 * * continued on next page ** M07 -223 Printed: 02 -05 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 40,).u) awl) Y-b )4r 71era 4/ �- doc: Cond -10/06 M07 -223 Date: ' ordinances governing or local laws regulating Printed: 02 -05 -2008 MO CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 iutp://ioviv.cLtulavilawa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** B 1 D & 1 - 1 'i tN 1 King Co Assessor's Tax No.: Q q n! t"i ,,n l5 Site Address: I 1 r � fl 1 (i l 1 L K- aripun'1. " g) VD. Suite Number: N/ �' Floor: R_60 F Tenant Name: P & all H P'i . 1 ' mifiUf Cj New Tenant: ❑ Yes ❑..No Property Owners Name: Abe Mir UD U - ,( MEP Muff, Mailing Address: PO PAY 3` Q'1 iieVs /w- l () eFP I tLE 1014 42'10 1 4 City State Zip CONTACT PERSON- who do we contact when your permit is rea R1 e-14. Dg.,L) Dayy Teellephone:02 85 1661 Mailing Address: Po ptX 31(m"1 i /L-1/5 1 - /0 St rZ t t t LE 14) f'(.. q Oic..f L/ / Q City State Zip E -Mail Address: V / , ` Fax Number: N � Name: GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg.4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD —All plans must be wet stamped by Architect of Record bit Contact Person: L. Ft 4 7}-10 H 7 Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No Project No. State Zip Company Name: Mailing Address: Zip Contact Person: E -Mail Address: City Day Telephone: Fax Number: State ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Compan Name:JP1 /U17 5L JJi i1F , Fnu i,1 - rT DtP77 Mailing Address: City f State /� Zip / /'�- Lee �1 L Day Telephone: � Li.D 5 ' / cQ (QUO- J� E2 E -Mail Address: Lee • L1 . L© /-T�� � RJb . �_bH Fax Number: cgL)112 - (X 5 - 5(? Q. Applications\Porms- Applications On Line\ -2006 • Permit Application.doc Revise& 9 -2006 Page 1 of 6 Unit Type: Qty Unit Type :. Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Re &ig/Cooling System Incinerator - Domestic Other Mechanical(, Equipment / ) .56 Alp !a) /6- Air Handling Unit <10,000 CFM Incinerator - Comm/Ind MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: &ei N 7 ?iV& q Caaom /Diu& Contact Person: .1 it l' f l rE/0 E -Mail Address. LL '9 �� Contractor Registration Number: .C.�' y ci�/T 141)1 Indicate type of mechanical work being installed and the quantity below: Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... Q:\ApplicationsWorms- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bh City State Zip [ ,, Day Telephone( /Jt - 7(0,2 • L/Q L 4 X • /QL Fax Number: 0 2Q ((J ' 7 143 e) Expiration Date: / Q /Q(a /D8 Valuation of Mechanical work (contractor's bid price): S n n n,� Sco s e of Work (please provide detailed information): L I 11...F -1112 l /L,f 1C .F I ftt f 7 OF- /_ I • ./ M 1.i t9 1' i� _ ,�I�� 7 � J Fuel Type: Electric EL{/ Gas....❑ Other: Page 4 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS AUTHORIZ C NT* Signature: ( tY p/u Saw Date: l6 /46/0 7 Print Name: ` TI9 / t ! rn FZ/ � 17 Day Te ` l e ' ph one: [� (o • 7 4 L) ridge] • �p� y�'f ,V , Mailing Address: L i Y / . si E it City State Zip Date Application Expires: al(f`l1(oB Date Application Accepted: Q: Applications\Forms- Applications On Line n -2006 - Permit Application.doc Revised: 9-2006 bh Staff Initi Page 6 of 6 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: Permit Number: M07 -223 Address: 11201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 10/19/2007 Applicant: BOEING #11 -14N Issue Date: Receipt No.: R07 -02293 Initials: JEM User ID: 1165 City of Tukwila RECEIPT Payee: SYSTEM BEATING AND AIR CONDITIONING CO., INC. TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES ,f Payment Amount: $640.09 Payment Date: 10/19/2007 12:12 PM Balance: $0.00 Amount Payment Check 24233 640.09 Account Code Current Pmts 000/322.100 640.09 Total: $640.09 doc: Receiot -06 Printed: 10 -19 -2007 Project: 4.70E/IV — i/— /VA/ Type of Inspection: / /Av4 / Address: 2q S // 5 Date Called: Special Instructions: Date Wanted: 0 2 - / j - oe Requester: Phone No: c 2. U 6- 5'7/-- zeS7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 r ii4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: i) nspec �i rr / -- /V //J j p/4/- 'lf721C 3' -) 3 -c) /4- 7e / //tl A $ .00 REINSPECTION FEE1REQUI�tE D. Prior to inspection, fee must be aid at 6300 Southcenter B vd.. Sfoiite 100. Call the schedule reinspection. (Receipt No.: 'Date: Date: Projec • /?t2 , � f/— /41V Inspection* Type of pectio PP/Y/1—AI Date Called: A�e� s : ii 2._ Special Instructions: Date Wanted: Requester: Phone No: COMMENTS: a s02D/lt's/ /)CLJA -S' ( n/4i) 41/4- (Z. , i /, / /e' &ioty/ lvy Zl,v,;i ) . ;;,�, /y , i , E ..., INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. El Corrections required prior to approval. spec •r: 00 REINSPECT! FEE R a id at 6300 Southcenter Blv INSPECTION RECORD Retain a copy with permit mo7.2,23 Date: IRED. Prior to inspection, fee must be :. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: October 23, 2007 Joe Cedena 9410 Delridge Way SW Seattle WA 98106 Dear Mr. Cedena: Enclosures File: M07 -223 city of Tukwlla RE: Letter of Incomplete Application # 1 Development Permit Application M07 -223 Boeing #11 -14N — 11201 Tukwila International Bl Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on October 19, 2007 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department needs to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have any questions concerning the following comments. 1. Revise plan notes to show compliance with 2006 International Building Codes. 2. Check plan set for compliance with current codes. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. P:\Permit Centcr\Incomplete Letters\2007M07 -223 Incomplete Ur #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M07 - 223 DATE: 01 -16 -08 PROJECT NAME: BOEING #11 -14 SITE ADDRESS: 9725 EAST MARGINAL WAY S Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bcl�ng "[division Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROdUTING: Please Route PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Fire Prevention Structural Incomplete Structural Review Required Planning Division Permit Coordinator DUE DATE: 01 -22 -08 Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 02 -19 -08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 - 223 DATE: 10 -19 -07 PROJECT NAME: BOEING #11 - 14N SITE ADDRESS: 11201 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued Public Works (43 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1 0-22-07 Complete ❑ Incomplete Comments: TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PERMIT MORD COPY PLAN REVIEW /ROUTING SLIP ,0W (' d Fire Prevention Structural ❑ Permit Coordinator No further Review Required DATE: DATE: Planning Division C Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: 101*4' LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 11-19-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwilawaus Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /// U/ /o U 4_ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: l` 6 pgc3, 66-tc_ol Steven M Mullet, Mayor l��• (J19dLn' a1v)la Steve Lancaster, Director Project Name: Project Address: �- Contact Person: Joe 010Q,1P,(//'Ia Phone Number: 0 74DD • Vo y9 y' /c Summary of Revision: leC�►V crrY OF TUKWItA JAN 16 2008 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: Et Entered in Permits Plus on ( ' t t 0 O \applications\forms- applications on linerevision submittal Created: 8 -13 -2004 ";"LATER License SYSTEHA19OBT Licensee Name SYSTEM HTNG & AIR COND CO INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600383522 Verify Workers Comp Premium Status Ind. Ins. Account Id 01/30/1981 Business Type CORPORATION Address 1 9410 DELRIDGE WAY SW Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067624249 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/30/1981 Expiration Date 10/2/2008 Suspend Date Separation Date Parent Company Previous License CRIMPIIVI40NA Next License Associated License Name Role Effective Date Expiration Date CRIMP, HERBERT V JR PRESIDENT 01/30/1981 CRIMP, MAXINE F SECRETARY 01/30/1981 CRIMP, JANINE L VICE PRESIDENT 09/28/2001 LVVl� V}J GL \/V1111G1vaVl, J./a■vaa avaaaaa va a awaaavva •...••••v •+v••.• Look Up a Contractor, Electrician or Plumber Printer Friendly Version License Information Business Owner Information Topic Index I Contact Info Search Home Safety r Claims & Insurance T Workplace Rights Trades & Licensing , Find a Law or Rule Get a Form or Publication General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. 1 Help https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= SYSTEHA190BT 02/05/2008 SCALE: NONE REPLACE COOUNG TOWER LOCATIO 556553-01 LM THOMAS I AUBURN I REV 1 1-7-08 REVISE CODE SUMMARY TO INDICATE 2006 IBC COMPLIANCE FOR CONSTRUCTION COMPLETED IN JULY 2007. 11.15.06 •;;;;;;;;,,,.,. PROJECT AREA prelARPreeed7r gLArawArAw ® BUILDING CODE: SEISMIC DESIGN: 11-14N BUILDING REPLACE COOLING TOWER PROJECT # 556553-01 OCCUPANCY GROUP: CONSTRUCTION TYPE: TYPE 1 TOTAL BUILDING AREA: CONSTRUCTION AREA: BUILDING HEIGHT: 103 FT STORIES: 5 GROUP = 1 CATEGORY = D LATITUDE = 47,33 LONGITUDE = —122.5 B-2 OFFICE, 8-1 PARKING 189,064 SQ FT 1,600 SQ FT APPROVED BY REV 1 1-7-08 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN LM THOMAS CHECKED ENGINEER CHECKED APPROVED APPROVED THAT PORTION OF GOVERNMENT LOT 2, SECTION 9, TOWNSHIP 23 NORTH, RANGE 4 EAST, W,M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTION OF THE NORTH UNE OF SAID GOVERNMENT LOT 2 AND THE WESTERLY MARGIN OF STATE ROAD NO.1; AND RUNNING THENCE ALONG SAID WESTERLY MARGIN OF STATE ROAD NO.1. S 18d57'20"W. 972.08 FEET MORE OR LESS, TO THE NORTH BANK OF THE DUWAMISH RIVER; THENCE WESTERLY, NORTHWESTERLY, AND NORTHERLY ALONG SAID BANK OF THE DUWAMISH RIVERTO ITS INTERSECTION WITH THE NORTH LINE OF SAID GOVERNMENT LOT 2; THENCE N 89d30'50E ALONG THE NORTH LINE OF SAID GOVERNMENT LOT 2, 845 FEET, MOE OR LESS, TO THE TRUE POINT OF BEGINNING. DATE 10.19.06 IBC INTERNATIONAL BUILDING CODE 2006, AS ADOPTED BY THE CITY OF TUKWILA I SPECTRAL ACCELERATION: I SHORT PERIOD Ss= 1.25g I 1SEC. S1= .42g CONTRACTOR: SITE ADDRESS: OWNER: OWNER CONTACT: RICK FORD (206) 854-1881 KINK COUNTY PARCEL NO. 0923049155 SEPARATE PEF1MIT REQUIRED FOR O Ig Electrical WPlumbing r Gas Piping City of Tukwila BUILDING DIVISION No cfratTes cis; tn the =pa of wo-k 011 Ot NOTE: nevisons rec,ure a new plan subrntat I and m_ay c'iudc addon& Di l reviefiste 1 OR 81,3UE F CONSTRJCT1ON 1/17/06 COVER SHEET REPLACE COOLING TOWER BUILDING 11-14N ARCHITECTURAL MASTER COL. X—X/X—X PROJECT S REPLACE EXISTING ONE CELL OPEN CIRCUIT COOLING TOWER WITH NEW TWO CELL UNIT. CURRENT UNIT HAS REACHED END OF SERVICE UFE. NEW UNIT WILL NOT ANY ADDITIONAL SEISMIC QUALIFICATIONS BOEING COMMERCIAL AIRPLANE SEATTLE DISTRICT P.O. BOX 3707, M/S: 1W-10 SEATTLE, WA. 98124-2207 FILE COPY Permit No. Plar review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipi of approved Fl . Copy ..r is acknowledged: • / By I Date: c W.61,0 DUWAMISH City of Tukwila BUILDING DIVISION CURRENT REVISION 556553-01 FEB 5 2.UOR JOB No. 556553-01 11-14N—A0 CE.:VF,E.ET JAN 1 6 2000 PERMIT OEN 11.15.06 7 A B C • • • • • • 11 -14 -AO 11 -14 -Al 11- 14 -A555 11- 14 -A556 11- 14 -A557 11- YRD -A3 11 -14N -5503 •_. 11- 14N -PM1OR 11- 14N -RFM1 OR 11- 14N -PM1 O 11- 14N -RFM3 •, 11- 14N -RFM1 O 1. l- 14N RFM1 .. ............... 11- 14 --M310 • 1 11- 14 -M326 • ° . . . . ....11-14 -M328 11-- 14 -M526 • 11- 14 --M540 • 11-- 14 -M555 Ot 11- 14 -M556 11- 14N- -PE210 • 11- 14 -E500 -EMCS • 11- 14 -E504 -EMCS RECORD DRAWING CAS OPERATIONS CENTER CAS ITAR AREA REPLACE COOLING TOWER REVISION AO Al A555 A556 A557 A3 S503 PM10R REM10R PM 1 O HVAC PARTIAL PLAN -- PENTHOUSE RFM3 RFM1O RFM11 M310 UNIT CONTROLS- CONTROL DIAGRAM - COOLING TWR N M326 M328 M526 I M540 M556 ARCHITECTURAL COVER SHEET DRAWING INDEX AND NOTES BLDG EXTERIOR ELEVATIONS RAF ONLY ENLARGED YARD COMPOSITE PLAN R F ONIIY ENLARGED PENTHOUSE PLAN NORTH R F ON Y COMPOSITE YARD PLAN - DUWAMISH TOWERS RtF ON Y ST r URA_ SLAB PENETRATIONS RESTRICTIONS MECHANICAL HVAC PARTIAL PLAN - PENTHOUSE HVAC PARTIAL PLAN - ROOF LEVEL - NORTH END COMPOSITE ROOF PLAN -NORTH TOWER HVAC PARTIAL PLAN - ROOF LEVEL - NORTH END HVAC PARTIAL PLAN - ROOF LEVEL - SOUTH END HVAC PIPING SCHEMATIC CONTROL SEQUENCES 11 -14N COOLING TOWER NORTH COOLING TOWER DETAILS HVAC SCHEMATIC M555 CONTROL DIAGRAM - NORTH COOLING TOWER 11 -14N COOLING TOWE DETAILS PE210 NORTH TOWER PENTHOUSE CONTROLS PLAN 1 500 -EMC CONTROL TRUNK RISER DIAGRAM 504 -EMC CMCS MBC -4 PANEL LAYOUT 504 -EMC CMCS MBC -4 PANEL LAYOUT 1 , r I E I J4982191 -00 150550 -00 150685 --02 556553 -01 BY HGI /LWR FOA FOA LM THOMAS APPROVED J. BURT WDH DATE 11.1.00 9.8.05 08.17.06 11.15.06 INDEX OF DRAWINGS R EF 0 n(os 17/os 17/06 17/06 17 06 n os F ON Y 11/17/06 7/06 17/06 1 17/061 i 1 /n /os 11/17/06 LY11/17/06 A 1/17/06 F 11/17/06 0 11/17/06 RF ON Y 11/17/06 A 11/17/06 0 11/17/06 0 1 11/17/06 11/17/06 1/17/06 1/17/06 REVISION 1• r 11 -14 -E5 11- 14N -PE11 OR 11- 14N -PE110 BY J I r APPROVED 11- 14N -E4A E4A I ONE UNE DIAGRAM - E5 I UPS & EMER POWER 1 -LINE PE11OR PE11O DATE � TR1CAL 208Y/120 VOLT POWER MAIN FEEDERS REMOVAL 277/480 VOLT SYSTEM Arrerwr BOE /NO' �•Wel0,111.1 L R A 11/17/06 11/17/06 11/17/06 11/17/06 f APPROVED BY XXX XXX TAKEN FROM SHEET — XXX XXX TAKEN FROM SHEET ----"* � — SHOWN ON SHEET GENERAL SYMBOLS BUILDING AND WALL XXX XXX SECTIONS TAKEN FROM SHEET — � SHOWN ON SHEET INTERIOR /EXTERIOR X XX XX ti� ELEVATION TAKEN FROM SHEET SHOWN ON SHEET ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED FLOOR NUMBER -- ROOM IDENTIFYING NUMBER WALL (N,S,E,W) DEPT. DATE SYMBOLS LEGEND FLOOR — SEQUENCE DRAWN LM THOMAS CHECKED ENGINEER CHECKED APPROVED APPROVED SEQ DATE 19.06 SHOWN ON SHEET COLUMN LINE INTERSECTION (TO NORTHWEST) COLUMN LINE INTERSECTION (TO NORTHWEST) SUET O-E ARCHITECTURAL MASTER DETAIL SECTION EFERENCE TO DETAIL P N ROOM NAME AND NUMBER INTERIOR DOOR NUMBER EXTERIOR DOOR NUMBER WALL TYPE SEE DESCRIPTION ON SHEET A508 SSUE FOR CON 1111710 DRAWING INDEX & NOTES REPLACE COOLING TOWER BUILDING 11 -14N GENERAL NOTES 1. THE CONTRACTOR SHALL SCHEDULE ALL WORK TO AVOID, AS MUCH AS POSSIBLE, ANY INCONVENIENCE TO EXISTING BUILDING OCCUPANTS, ESPECIALLY DURING DEMOLITION OF EXISTING FACILITIES. AREAS UNDER CONSTRUCTION SHALL BE PROPERLY SCREENED OFF BY TEMPORARY SCREENS OR PARTITIONS. 2. THE CONTRACTOR SHALL KEEP AREAS UNDER CONSTRUCTION CLEAR OF DIRT AND DEBRIS CAUSED BY DEMOLITION AND SHALL STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREAS DESIGNATED BY THE BOEING CONSTRUCTION MANAGER. 3. THE CONTRACTOR SHALL REPAIR DAMAGED SURFACES AND CORRECT CONDITIONS CAUSED BY DEMOLITION TO MATCH SURROUNDING FINISHED CONDITIONS OR AS INDICATED ON THESE DRAWINGS. 4. THE CONTRACTOR IS TO VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND SHALL BE RESPONSIBLE FOR THE JOINING OF HIS WORK TO THE EXISTING CONSTRUCTION AND THE WORK OF OTHER TRADES. DISCREPANCIES ON DRAWINGS OR IN SPECIFICATIONS, SHALL BE BROUGHT TO THE ATTENTION OF THE BOEING CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY. 5. ALL WORK SHALL CONFORM WITH ALL APPLICABLE CODES AND REGULATIONS. 6. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL 7. PRIOR TO INSTALLING FINISH FLOORING, INSPECT, PATCH AND REPAIR ALL SURFACES TO PROVIDE A SMOOTH, FLAT SURFACE THROUGHOUT. 8. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. 9. PLANS WHICH APPEAR AS BACKGROUNDS ON CIVIL, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL DRAWINGS, ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. 10. THE GENERAL CONTRACTOR AND RESPECTIVE SUBCONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION OF CIVIL, ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL WORK. 11. THE DRAWING CONSTRUCTION NOTES APPLY ONLY TO THE DRAWING SHEETS ON WHICH THEY ARE WRITTEN. 12. WHERE COLUMN ENCLOSURES OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THIS ROOM UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PREFORMED TO THE HIGHEST TRADE STANDARDS. 13. ALL WORK SHALL BE PERFORMED TO THE HIGHEST TRADE STANDARDS. 14. ALL WORK SHALL BE PERFORMED IN A SAFE MANNER IN ACCORDANCE WITH 0.S. HA & W.I.S.H.A. 15. THE CONTRACTOR SHALL DISPOSE OF ALL REMOVED MATERIAL UNLESS HAZARDOUS MATERIALS ARE DISCOVERED OR SUSPECTED, IN WHICH CASE THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE BOEING CONSTRUCTION MANAGER. THE SUSPECTED MATERIALS SHALL NOT BE HANDLED OR DISPOSED OF UNTIL DIRECTED BY BOEING. 16. THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE CONSTRUCTION MANAGER IF ASBESTOS IS DISCOVERED OR SUSPECTED ON THIS PROJECT. THE SUSPECTED MATERIAL SHALL NOT BE DISTURBED UNTIL IT HAS BEEN INSPECTED AND REMOVAL HAS BEEN APPROVED BY BOEING. 17. DO NOT ANCHOR INTO CONCRETE SLAB WITHOUT X- RAYING SLAB. SEE REF. DRAWING S -503 A rRucTRON DUWAMISH, WA CURRENT REVISION 556553-01 SHEET �O AP r Al SYMBOL JOB NO. 556553 -01 DWG NO. - y er G; , c 11- 14N -A1 JAN 16 2008 PERMIT C.NTE DATE COMP NO. 11.15.06 IC, 0 SYM A B C D E TIc CT-IN SIDE B.F.P. u ;2=1. AT PUMP SER ENTER U FUTURE PIMP LOCAl10 BACKDRAFT- DAMPER R FIELD 30"W x 301 LOUVER BY OTHERS REVISION NOTE SEE ARCH PLANS SHT A -31 FOR RELIEF SIM TO ELEV SHAFT IEF -141J ADDED EF -14N & MODIFIED FAN SYSTEM ADDED CONCRETE PLYNTHS, COND PIPE DTL ADDED KITCHEN EXHAUST FANS AND DETAILS 11 -14 EYEWASH 11 -14 EYEWASH 571035 571035 BY RD RD RD QC QC L 72'W x 72 "H LOUVER BY OTHERS APPROVED LS LS v - 1 ELEV SHAFT IEF -1311 DATE 03/10/88 04/06/88 10/27/88 12/14/93 0 SYM F R AS -BUILT REPLACE COOLING TOWER PLENUM RM REVISION INTAKE LOUVER r BY OTHERS INSULATE & HEAT TRACE EXPOSED PIPE 10` HYDRONIC RISER NORTH PENTHOUSE ENLARGED PLAN SCALE: 3/16" =1'0" INTAKE LOUVER BY OTHERS 60% FREE AREA TYP UN O. 571035 556553 -01 BY QC LM THOMAS AS POSSIBLE • : APPROVED LS WDH BLDG SIDE BY B CONTR CT -1N SIDE BLDG SIDE DATE 03/09/94 11.15.06 PM1 I M526 ROUTE PIPING A -' GWB ENCLOSURE SEE ARCH PLAN STAIR "B" SHT A -36 30 FUTURE PUMP I HXC -1 NI HM-2ND 3/4" CW 1 1. /2:'..DRAIN_ SEE DETAIL FD EMERGENCY ,1 EYEWASH 11- 14N -PM10 MECHANICAL TOILET EX eLBO /NG 72"W x 3 "H LOUVER BY OTH 4 4 IN BD-6 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAIN FD BY PLUMB CONTR COOLING TOWER RM RD B H f M529 01/14/88 TITLE SUBTITLE HVAC SYSTEMS - PENTHOUSE REPLACE COOLING TOWER BUILDING 11 -14N MECHANICAL MASTER COL. C -D /M -Q LEGEND GENERAL NOTES COLUMN LOCATIONS BASED ON ORIGINAL BUILDING CONSTRUCTION COLUMN LOCATIONS BASED ON REVSION TO STANDARD BOEING COLUMN DESIGNATION REFERENCE DRAWINGS 11- 14N -RFM10 PARTIAL ROOF PLAN — NORTH HALF 11 - 14N —RFM11 PARTIAL ROOF PLAN — SOUTH HALF 11- 14 —M500 DETAILS, SECTIONS, & ELEVATIONS, PENTHOUSE CONSTRUCTION NOTES trz.'cb DRAIN COOLING TOWER WATER SYSTEM AND DRAIN SUMPS DISCONNECT COOLING WATER, MAKE UP WATER, AND SUMP DRAIN CONECTIONS FROM EXISTING COOLING TOWER AFTER DRAINING UNIT. DISCONNECT POWER AND CONTROL CONNECTIONS TO THE TOWER ISSUE FOR CONSTRUCTION 11t', 7IOB STAGE CRANE IN PARKING LOT RATED TO PICK UP TOWER. PROVIDE LIFTING CONNECTIONS RATED AS NEEDED TO SAFELY PICK ENTIRE TOWER AND MOVE TO GROUND LIFT COOLING TOWER FROM INSTALLED POSITION IN PENTHOUSE AND RELOCATE TO GROUND LEVEL. PREPARE TOWER FOR TRANSFER TO SURPLUS SALES CH CKED ENGINEER CHECKED APPROVED APPROVED DUWAMISH, WA CURRENT REVISION 556553 -01 SHEET SYMBOL PMIOR JOB NO. 556553 -01 DWG NO. 11- 14N - PM1 OR JAN 16 2008 PERMIT CENTER DATE 11.15.06 COMP NO. 5YM A B R AS -BUILT BY WOOD HARBINGER REVISED PENTHOUSE AREA REPLACE COOLING TOWER REVISION :M ROOM 556553 -01 i BY MWS RLM LM THOMAS APPROVED WDH GATE 12/31/92 10/05/94 11.15.06 f ROOF LEVEL PARTIAL P _.AN SCALE: 3/32 1'O REVISION BY APPROVED DATE gLAPPAw,Aw ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE D PT717/92 SUBTITLE ' c "o r") : - ,P, r ;C \; '? :: :i r : ;, \-- ,; - s,%1 1) ISSUE F R. CONSTRUCTION 11/17/16 MECHANICAL MASTER PARTIAL ROOF PLAN - NORTH HALF REPLACE COOLING OTWER BUILDING 11 -14N ELECTRICAL SPECIFATION COL A- G/1- -6 DUWAMISH, WA LEGEND GENERAL NOTES CT-1N MECHANICAL SPECIFICATION OPEN TYPE COOLING TOWER EVAPCO MODEL LSTA 10-187 598.7 MBTUH NOMINAL HEAT RUCTION AT 2303 GPM 91F EWT, 81F LWT, AND 67F WG OAT OPERATING WEIGHT: 26,000 LBS EMPTY WEIGHT: 13,000 LBS HIGH SPEED FANS:2 EACH 50 HP 65 AMPS LOW SPEED FANS: 2 EACH 15 HP 21 AMPS BASIN HEATERS: 2 EACH 5 KW DIVIDED WET DECK SECTION PARTITION DIVIDED PAN SSECTION WITH COMMON SUMP CAPACITY CONTROL DAMPERS AT FAN DISCHARGE \\ 460 VAC 3 PHASE POWER 4 EACH HAND /OFF /AUTO MOTOR SWITCHES 2 EACH HI SPEED FAN MOTOR CONTACTORS AND RELAYS 2 EACH LO SPEED FAN MOTOR CONTACTORS AND RELAYS 2 PAN HEATER CONTACTORS TIE DELAY RELAY ( OFF DELAY 0 TO 1205 ) REFERENCE DRAWINGS 11- 14 -M500 DETAILS, SECTIONS, AND ELEVATIONS PENTHOUSE 11- 14 -M540 HVAC PIPING SCHEMATIC 11- 14N -RFM3 COMPOSITE ROOF PLAN - NORTH TOWER 11- 14N -PM10 HVAC SYSTEMS PENTHOUSE CONSTRUCTION NOTES di t REPLACE EXISTING COOLING TOWER WITH NEW TOWER AS DESCRIBED IN GENERAL NOTES ABOVE. ALSO REFER TO THE SCOPE OF WORK AND TOWER SPECIFICATION PROVIDED AS A SEPERATE DOCUMENT. MECHANICAL COOLING IN 11 -14N WILL BE NOT BE AVAILABLE UNTIL NEW TOWER HAS BEEN INSTALLED AND COMISSIONED EXCEPT FOR AC-1N WHICH CAN BE TIED INTO THE 11 -14S FLUDI COOLING USING THE GARAGE LEVEL INTERTIE LINE AND THE NEW RISER ISOLATION VALVES UNDER JOB 150689 -00. ALL FLOORS WILL BE RUNNING ON 100% OUTSIDE AIR FOR COOLING UNTIL WORK IS COMPLETED. rt JAN 1 6 2008 PERMIT CENTER DRAWN MWS KED ENGINEER CHECKED APPROVED APPROVED CURRENT REVISION 556553 -01 KEY PLAN SCALE: NONE SYMBOL R SHEET RFM10R JOB NO. 556553 -01 DWG NO. DATE 11-14N-RFM1OR COMP NO. 11.15.06 SYM A B C D E REVISION NOTE SEE ARCH PLANS SHT A -31 FOR RELIEF 30'Wx30"H LOUVER BY OTHERS ADDED EF -14N & MODIFIED FAN SYSTEM ADDED CONCRETE PLYNTHS, COND PIPE DTL ADDED KITCHEN EXHAUST FANS AND DETAILS 11 -14 EYEWASH 11 -14 EYEWASH 571035 571035 BY RD RD RD QC QC AS, 721W x 72 "H LOUVER BY OTHERS APPROVED LS LS DATE 03/10/88 04/06/88 10/27/88 12 /14 /9 3 02 /10 /9 4 SYM F G SCALE 3/16"=1'0' AS —BUILT REPLACE COOLING TOWER REVISION INTAKE LOUVER BY OTHERS PLENUM RM INSULATE & HEAT TRACE EXPOSED PIPE 10" HYDRONIC RISER —IT NORTH PENTHOUSE ENLARGED PLAN INTAKE LOUVER BY OTHERS 60% FREE AREA TYP UNO. 571035 556553-01 BY QC LM THOMAS APPROVED LS WDH S ITT M18 FO PIPI s DATE 03/09/94 11.15.06 IHNC -2nd BLDG SIDE BY B CONTR CT -1N SIDE BLDG SIDE SEE DETAIL 30 FUTURE PUMP 11 -14N —PM10 M529 PM11 M526 ROUTE PIPING A GWB ENCLOSURE SEE ARCH PLAN STAIR "8" SHT A -36 elLefirl5WFAf • ROUTE sIPE AT PUMP SUCTIOhDIFFUSER CONNE CENTER L PUMP LOCATION DAMPER R FIELD DRAIN FD BY PLUMB CONTR COOLING TOWER RM ACCEPTABI THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEFT. DATE RD CH CKED ENGINEER CSI ECKED APPROVED APPROVED ti DATE 14/88 CONTROLLERS"?' 1YP SUBTITLE -r �f> COLUMN LOCATIONS BASED ON ORIGINAL BUILDING CONSTRUCTION Ez>. LIFT COOLING TOWER FROM STAGING LOCATION IN PARKING LOT AND INSTALL IN PENTHOUSE ON EXISTING SUPPORTS. CONNECT ELECTRICAL POWER AND CONTROL CONNECTIONS TO THE NEW COOLING TOWER " CONNECT COOLING WATER, MAKE UP WATER, AND SUMP DRAIN LINES TO NEW COOLING TOWER. LEGEND ISSUE FOR +f. CONSTRUCTION 1/17/06 TITLE REPLACE COOLING TOWER MECHANICAL MASTER HVAC SYSTEMS - PENTHOUSE BUILDING 11 -14N COL C -D /M -Q GENERAL NOTES COLUMN LOCATIONS BASED ON REVSION TO STANDARD BOEING COLUMN DESIGNATION REFERENCE DRAWINGS 11 --14N —RFM 1 O PARTIAL ROOF PLAN — NORTH HALF 11-14N—RFM11 PARTIAL ROOF PLAN — SOUTH HALF 11- 14 —M500 DETAILS, SECTIONS, & ELEVATIONS, PENTHOUSE DUWAMISH, WA CONSTRUCTION NOTES STAGE CRANE IN PARKING LOT RATED TO PICK UP NEW TOWER. PROVIDE LIFTING CONNECTIONS RATED AS NEEDED TO SAFELY PICK ENTIRE TOWER AND MOVE TO PENTHOUSE FILL PIPING AND TOWER AND STARTUP NEW TOWER CURRENT REVISION 556553 -01 SHEET JOB NO. DWG NO. SYMBOL PM10 556553 -01 JAN 1 6 2008 DATE 11 -14N —PM10 PER WO GE-LATER COMP NO. 11.15.06 SYM REVISION A AS —BUILT BY WOOD HARBINGER B REVISED PENTHOUSE AREA REPLACE COOUNG TOWER DAWN WY PLUMB CORM 3/4' cw 4" CM ra: SAMORaFF R4 6 EYFQf�IJF'1• F a ., • 556553 -01 EYEWASH FUTURE puw LocAnoN WILOSM MWS RLM ROM DETAIL LM THOMAS PI11 + M526 APPROVED WDH FUTURE POW 31 BY OTFERs DATE SEE DETAIL ROUTE BR SEE AM RAN STAR 'a' sHr.•A -3G — iumt !! ...•'•'ter_ . F. . i•• _. n .... ^ti 12/31/92 10/05/94 11,15.06 v'. q MINN OMB Fp COMM TOWER RM DAMPEEt CONTROLLER BY OTIiERS TYP ROOF LEVEL PARTIAL PLAN SCALE: 3/32"=1'0" REVISION BY It• APPROVED DATE j7t BOE /M • :t ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED MWS ENGINEER CHECKED APPROVED APPROVED 11/17/92 SUBTnLE TITLE \ ,... -,-... F°\I. MECHANICAL MASTER 'i � U t` FOR CONSTRUCTION 11117/06 PARTIAL ROOF PLAN - NORTH HALF REPLACE COOLING OTWER BUILDING 11 -14N COL. A -G /1 -6 LEGEND GENERAL NOTES REPLACEMENT CT-1N MECHANICAL SPECIFICATION OPEN TYPE COOLING TOWER EVAPCO MODEL LSTB 10618 OR EQUAL 598.7 MBTUH NOMINAL HEAT REJCTION AT 2303 GPM 91F EWT, 81F LWT, AND 67F WG OAT OPERATING WEIGHT: 26,000 PLUS LBS VARIABLE SPEED FANS WITH INVERTER RATED MOTORS: 2 EACH 50 HP 65 AMPS BASIN HEATERS: 2 EACH 5 KW DIVIDED WET DECK SECTION PARTITION DIVIDED PAN SECTION WITH SEPERATE STAINLESS STEEL SUMPS ELECTRICAL SPECI FAT' ON 460 VAC 3 PHASE POWER 2 EACH BYPASS /OFF /VARIABLE VARIABLE FREQUENCY DRIVES WITH EMBEDDED SUPPORT OF SBT P1 FLN NETWORK INTERFACE. 2 PAN HEATER CONTACTORS 11- 14N —RFM3 11- 14N —PM1 O 11- 14N- -RFM11 1 1-14—M326 11-- 14 —M328 1 1- 14 —M540 11- 14N —PE21 O 1) • DUWAMISH, WA REFERENCE DRAWINGS COMPOSITE ROOF PLAN - NORTH TOWER HVAC SYSTEMS PENTHOUSE PARTIAL ROOF PLAN — SOUTH HALF HVAC PIPING SCHEMATIC CONTROL SEQUENCES 11 -14N COOLING TOWER HVAC PIPING SCHEMATIC CMCS CONTROLS — PENTHOUSE PLAN CONSTRUCTION NOTES 5 11, REPLACE EXISTING COOLING TOWER WITH NEW TOWER AS DESCRIBED IN GENERAL NOTES ABOVE. ALSO REFER TO THE SCOPE OF WORK AND TOWER SPECIFICATION PROVIDED AS A SEPERATE DOCUMENT. MECHANICAL COOLING IN 11 -14N WILL BE NOT BE AVAILABLE UNTIL NEW TOWER HAS BEEN INSTALLED AND COMISSIONED EXCEPT FOR AC -1N WHICH CAN BE TIED INTO THE 11 -145 FLUDI COOLING USING THE GARAGE LEVEL INTERTIE LINE AND THE NEW RISER ISOLATION VALVES UNDER JOB 150689 -00. ALL FLOORS WILL BE RUNNING ON 100% OUTSIDE AIR FOR COOLING UNTIL WORK IS COMPLETED. • JAN 16 2008 PE S ill CENTER CURRENT REVISION 556553 -01 SHEET JOB NO. DWG NO. SYMBOL C RFM10 556553 -01 KEY PLAN SCALE: NONE 11 -14N -RFM10 M DATE 11.15.06 COMP NO. 8 • r . . REPLACE COOUNG TOWER i ; REVISION 5 .. 5 ................ . \.... 5 .... ... .: .. .• .... fir' F'''-' ." •"''' F �, 556553 -01 BY LM THOMAS APPROVED WDH DATE 11.15.06 MOEN EXHAUST 3OWlx OTHERS NOTE: sSEE PLANS FOR RELIEF REVISION .W,.. • CO VI POSITE ROOF PLAN NORTH TOWER SCALE: 3/32 =1'0" BY ROUTE HIGH AS POSSIBLE INTAKE LOWER BY OTHEFIS sox FREE AREA TYP UNO. COLAIJST FAN APPROVED DATE SEE DETAIL N a ewe PlAll 3R . . ww.cs . , DAN FD =MCI TOM Mil 1.._Arate CONTROLLER TfP ACCEPTABI LITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED APPROVED APPROVED DATE 201.06 10.20.06 SUBTITLE ISSUE CONSTRUCTION 11117106 MECHANICAL MASTER JAN 16 2008 =° ti ij LATER REPLACE COOLING TOWER BUILDING 11 -14N COL. A -G/ -12 1) 11- 14N -A555 11- YRD -A3 11-- 14N -RFM10 11- 14N -RFM11 11-- 14N -PE210 11 -14 -5503 1) 2) 1 COMPOSITE ROOF PLAN - NORTH TOWER BUILDING FLOORS ARE CONSTRUCTED USING POST TENSIONED CONCRETE WITH CABLES. LOCATE CABLES BEFORE ANY CORING OR DRILLING WITH GROUND PENETRATING RADAR. REFERENCE DRAWING 11 -14 -5503 LEGEND DUWAMISH, WA GENERAL NOTES REFERENCE DRAWINGS BUILDING EXTERIOR ELEVATIONS COMPOSITE YARD PLAN - DUWAMISH TOWERS PARTIAL ROOF PLAN NORTH HALF PARTIAL ROOF PLAN SOUTH HALF CMCS CONTROLS - PENTHOUSE PLAN SLAB PENETRATION DETAILS CONSTRUCTION NOTES SURVEY 11 -14N PENTHOUSE AND COOLING TOWER INSTALLATION TO DETERMINE EXACT CONFIGURATION OF REPLACEMENT FOR EXISTING COOUNG TOWER. PROCURE NEW COOLING TOWER AS CALLED IN SPECIFICATION PROVIDED WITH DESIGN PACKAGE. REMOVE EXISTING COOLING TOWER WHICH HAS REACHED THE END OF ITS SERVICE LIFE. SEE SHEETS 11- 14N- RFM1OR FOR ORIGINAL COMPONENT SPECIFICATION AND 11- 14 -M538 FOR SEQUENCE OF OPERATION. USE ARCHITECTURAL PLANS PROVIDED TO COORDINATE CRANE POSITIONING IN PARKING LOT. DURING REMOVAL OF COOLING TOWER, THE MECHANICAL COOLING STAGES ON AIR CONDITIONERS FOR FLOORS 2 THROUGH 5 WILL BE UNAVAILABLE 3) INSTALL NEW COOLING TOWER TO REPLACE UNIT REMOVED. SEE SHEETS 11- 14N -RFM10 FOR NEW COMPONENT SPECIFICATION AND 11- 14 -M538 FOR SEQUENCE OF OPERATION. USE ARCHITECTURAL PLANS PROVIDED TO COORDINATE CRANE POSITIONING IN PARKING LOT. CONNECT NEW TOWER TO BUILDING PIPING SYSTEM AND INTERFACE TO EXISTING BUILDING CONTROL SYSTEM ( CMCS ) TO PROVIDE OPERATION AS CALLED OUT IN DRAWINGS CURRENT REVISION 556553 -01 SHEET JOB ND. DWG NO. SYMBOL RFM3 556553 -01 0 in 11 -14N --RFM3 DATE 11.15.06 COMP NO. 6 6 ISSUED FOR CONSTRUCTION REPLACE COOLING TOWER 556553 -01 SCHILLE LM THOMAS 11.15.06 APPROVED BY DEPT. DATE 05 01 97 05 01 97 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DF MIME DRAWN SCHILLE CHECKED CONTROL DIAGRAM- 11 -14N COOLING TOWER MECHANICAL MASTER REPLACE COOLING TOWER BUILDING 11 -14 COL. X-X/X-X DUWAMISH, WA CURRENT REVISION 556553 -01 JOB NO. COMP NO. 556553 -01 11-- 14 -M310 DWG NO. DI FAST SLOW TO STARTERS SPRAY PUMP SCROLL DAMP 1 TWR. PUMP P -1 TWR. PUMP P -1 TWR. PUMP P -2 TWR. PUMP P -2 TWR. PUMP P -5 TWR. PUMP P -5 I- I- I- = z s FAN 2 LOW FAN 2 HI SCROLL DAMP 2 DO DI DO DI DO DI REVISION 3 -135 TO SCROLL DAMP. ACTUATOR TYP 2 TO STARTERS AOP DO DI DO Al Al FAST SLOW COOLING TOWER CONTROL - NORTH Al Al 28.1 28.2 ZLA irO /A /G' ".BLDG.RTEMP" ".BLDG.DTEMP" BLDG. PUMP P -3 BLDG. PUMP P -3 BLDG. PUMP P -4 BLDG. PUMP P -4 BLDG. PUMP P -6 BLDG. PUMP P -6 1 1-- 14 - M328 CONTROL SEQUENCES 11 -14N COOLING TOWER 11- 14 -M555 CONTROL DIAGRAM - NORTH COOLING TOWER 1 1 -14-E504-EMCS CMCS -- MBC -4 PANEL LAYOUT - NORTH COOLING TOWER LEGEND GENERAL NOTES SEE DRAWING 1 1- 14 --E504 -EMCS FOR MBC -4 POINT NAMES AND WIRING TERMINATIONS REFERENCE DRAWINGS CONSTRUCTION NOTES DISCONNECT EXISTING CONTROL WIRING FROM CURRENTLY INSTALLED COOLING TOWER PRIOR TO REMOVING FROM THE PENTHOUSE REVISE CMCS SYSTEM CONTROLS TO SUPPORT NEW TWO CELL COOLING TOWER EQUIPPED WITH ONE FAN PER CELL AND ALLEN BRADLEY / ROCKWELL VARIABLE FREQUENCY DRIVE PROVIDING CAPACITY CONTROL FOR NEW TOWER PROVIDE REDLINE OF THES DRAWING DOCUMENTING NEW CONTROL INTERFACES PERT CENTEk 11.15.06 t to . SEQUENCE OF OPERATION -- NORTH TOWER CONDENSER WATER COOLING SYSTEM — ORIGINAL CONFIGURATION THE ORIGINAL COOLING SYSTEM IS ARRANGED FOR 24 HOUR OPERATION COOLING TOWER CONSISTS OF A 2 CELL TOWER. EACH CELL HAS A DESIGNATED SPRAY PUMP, AND 2 SPEED FAN WITH VOLUME DAMPER. EACH TOWER CELL IS CONNECTED TO A WATER TO WATER HEAT ECHANGER. PUMP 5 IS FOR LOW DEMAND AND EMERGENCY POWER OPERATION. PUMP 5 IS CONNECTED TO CELL 1. TOWER FANS ARE 2 SPEED FANS. FAN 1 LOW SPEED IS ON EMERGENCY POWER. FANS LEAD LAG WITH ASSOCIATED TOWER PUMPS BASED ON OPERATOR COMMAND. ON PUMP FAILURE LAG PUMP BECOMES LEAD. BUILDING CONDENSER PUMPS P -3, P -4, P -6. P -3 AND P -4 RUN CONTINUOUSLY EXCEPT ON MAMOTH DX LOCKOUT OR EMERGENCY POWER. DURING DX LOCKOUT OR EMERGENCY POWER P -6 RUNS. P -6 IS ON EMERGENCY POWER. LEAD /LAG OPERATION IS BY OPERATOR COMMAND. WHEN SYSTEM RETURNS FROM EMERGENCY POWER PUMPS P -5 AND P -6 MUST BE RELEASED TO NORMAL OPERATION BEFORE CMCS SYSTEM WILL STOP PUMPS. TOWER MODE. TOWER MODE EFFECTS ONLY COOLING TOWER FANS AND COOLING TOWER PUMPS. COOLING TOWER MODE IS CONTROLLED BY BUILDING CONDENSER DISCHARGE WATER TEMPERATURE. MODE 0. COND MODE 1 GOND MODE 2. BLDG MODE 3. BLDG MODE 4. BLDG MODE 5. BLDG MODE 6. BLDG DICH TEMP DICH TEMP COND DICH COND DICH COND DICH COND DICH COND DICH C78 DEG F. 78 -80 DEG F. TEMP 80 -82 DEG F. TEMP 82-84 DEG F. TEMP 84 -86 DEG F TEMP 86 -87 DEG F TEMP > 87 DEC F. SEQUENCE OF OPERATION — NORTH TOWER CONDENSER THE REVISED COOLING SYSTEM IS ARRANGED FOR 24 HOUR OPERATION COOLING TOWER CONSISTS OF A 2 CELL TOWER. EACH CELL HAS A DESIGNATED SPRAY PUMP, AND VARIABLE SPEED DRIVE EQUIPPED FAN WITH VOLUME DAMPER. EACH TOWER CELL IS CONNECTED TO A WATER TO WATER HEAT ECHANGER. PUMP 5 IS FOR LOW DEMAND AND EMERGENCY POWER OPERATION. PUMP 5 IS CONNECTED TO CELL 1. TOWER FANS MOTORS ARE INVERTER RATED AND EACH EQUIPPED WITH A VARIABLE FREQUENCY DRIVE. BOTH FANS ARE PROGRAMMED TO RUN AT A LOW SPEED WHEN ON STANDY BY POWER. FANS LEAD LAG WITH ASSOCIATED TOWER PUMPS BASED ON OPERATOR COMMAND. ON PUMP FAILURE LAG PUMP BECOMES LEAD. BUILDING CONDENSER PUMPS P -3, P -4, P -6. P -3 AND P -4 RUN CONTINUOUSLY EXCEPT ON MAMOTH DX LOCKOUT OR EMERGENCY POWER. DURING DX LOCKOUT OR STANDBY POWER P -6 RUNS. P -6 IS ON STANDBY POWER. LEAD /LAG OPERATION IS BY OPERATOR COMMAND. WHEN SYSTEM RETURNS FROM EMERGENCY POWER PUMPS P-5 AND P -6 MUST BE RELEASED TO NORMAL OPERATION BEFORE CMCS SYSTEM WILL STOP PUMPS. TOWER MODE. TOWER MODE EFFECTS ONLY COOLING TOWER FANS AND COOLING TOWER PUMPS. COOLING TOWER MODE IS CONTROLLED BY BUILDING CONDENSER DISCHARGE WATER TEMPERATURE. MODE 0. COND DICH TEMP < 78 DEG F. MODE 1 COND DICH TEMP 78 -80 DEG F. MODE 2. BLDG GOND DICH TEMP 80 -82 DEG F. MODE 3. BLDG COND DICH TEMP 82 -84 DEG F. MODE 4. BLDG GOND DICH TEMP 84 -87 DEG F MODE 5. BLDG COND DICH TEMP > 87 DEG F. REVISION REPLACE COOLING TOWER 556553 -01 BY LM THOMAS APPROVED WDH DATE 11,15.06 REVISION EMERGENCY POWER MODE. PUMP 5 (ON EMERGENCY POWER) IS ON. PUMP 6 (ON EMERGENCY POWER) IS ON.. TOWER FAN 1 SLOW IF NEEDED. TOWER FAN 1 VOLUME DAMPER MODULATES TO MAINTAIN TEMP SETPOINT OF 82 DEG F. MODE 0. PUMP 5 ON. MODE 1. LEAD TOWER PUMP ON. MODE 2. LEAD AND LAG TOWER PUMPS ON. MODE 3. LEAD AND LAG TOWER PUMP ON. LEAD TOWER FAN ON. LEAD VOLUME DAMPER MODULATES TO MAINTAIN LEAD TEMP SETPOINT 82 DEG F. MODE 4. LEAD AND LAG TOWER PUMPS ON. LEAD TOWER FAN ON SLOW. LEAD VOLUME DAMPER MODULATES TO MAINTAIN LEAD TEMP SETPOINT 82 DEG F. LAG TOWER FAN ON SLOW. LAG VOLUME DAMPER MODULATES TO MAINTAIN LAG TEMP SETPOINT OF 84 DEC F. MODE 5. LEAD AND LAG TOWER PUMPS ON. LEAD TOWER FAN ON FAST. LEAD VOLUME DAMPER MODULATES TO MAINTAIN LEAD TEMP SETPOINT 82 DEG F. LAG TOWER FAN ON SLOW. LAG VOLUME DAMPER MODULATES TO MAINTAIN LAG TEMP SETPOINT OF 84 DEG F. MODE 6. LEAD AND LAG TOWER PUMPS ON. LEAD TOWER FAN ON FAST. LEAD VOLUME DAMPER MODULATES TO MAINTAIN LEAD TEMP SETPOINT 82 DEG F. LAG TOWER FAN ON FAST. LAG VOLUME DAMPER MODULATES TO MAINTAIN LAG TEMP SETPOINT OF 84 DEG F. WATER COOLING SYSTEM VFD CONFIGURATION EMERGENCY POWER MODE. PUMP 5 ON EMERGENCY POWER) IS ON. PUMP 6 ON EMERGENCY POWER) IS ON.. TOWER FAN 1 SLOW IF NEEDED. TOWER FAN 1 SPEED MODULATES TO MAINTAIN TEMP SETPOINT OF 82 DEG F. MODE 0. PUMP 5 ON. MODE 1. LEAD TOWER PUMP ON. MODE 2. LEAD AND LAG TOWER PUMPS ON. MODE 3. LEAD AND LAG TOWER PUMP ON. LEAD TOWER FAN ON. LEAD TOWER FAN SPEED MODULATES TO MAINTAIN LEAD TEMP SETPOINT 82 DEG F. MODE 4. LEAD AND LAG TOWER PUMPS ON. LEAD TOWER FAN ON. LEAD FAN SPEED MODULATES TO MAINTAIN LEAD TEMP SETPOINT 82 DEG F. LAG TOWER FAN ON. LAG FAN SPEED MODULATES TO MAINTAIN LAG TEMP SETPOINT OF 84 DEG F. MODE 5. LEAD AND LAG TOWER PUMPS ON. LEAD TOWER FAN ON. LEAD FAN SPEED INCREASES TO 100% LAG TOWER FAN ON. LAO FAN SPEED INCREASES TO 100% .,'AJ BY APPROVED DATE �BOE /N!9 ACCEPTABILITY THIS DESIGN AND /DR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED APPROVED APPROVED DATE 10.24.06 ISSUE, FOR CONoTRUCTION I 1 /1 7106 MECHANICAL MASTER SLUffLE CONTROL SEQUENCES 11-14N COOLING TOWER REPLACE COOLING TOWER GENERAL NOTES 1) SEQUENCES OF OPERATION WERE ORIGINAL SHOWN ON SHEET 11- 14 -M310 AND WERE TRANSFERRED TO THIS SHEET TO IMPROVE DRAWING LEGIBILITY REFERENCE DRAWINGS 1 1- 14 —M310 CONTROL DIAGRAM 11 -14N COOLING TOWER 11- 14- --M326 HVAC PIPING SCHEMATIC 11-14-M526 HVAC PIPING DETAILS - NORTH TOWER 1 1- 14 -M555 CONTROL DIAGRAM - NORTH COOLING TOWER BUILDING 11 -14 COL. X -X /X -X iveW . e °6 ,‘, 1) CMCS CONTROLS CONTRACTOR SHALL MODIFY THE BUILDING CMCS HARDWARE AND PROGRAMMING TO PROVIDE THE SEQUENCE OF CONTROL SHOWN ON THIS SHEET \ CODf: Csj ,...,,, qr-.:' VI - c- ----7 r ---- 7 4 C. -1 ;' 3 '' ' 1 , FmY u: a;. , LEGEND DUWAMISH, WA CONSTRUCTION NOTES CURRENT REVISION SHEET JOB NO. DWG NO. SYMBOL M328 556553-01 11 -14 -M328 DATE 11.15.06 ._ JAN 16 2008 PERMiT COMP NO. t 0 SYM A INTLK TO SPRAY PUMP CAPACITY CONTROL ; FAN DAMPERS INITIAL RELEASE REPLACE COOUNG TOWER REVISION - TO- -DRAIN 9 0 A Qom-- TYP 4" CONN 556553 -01 150550 -00 TO DRAIN SPRAY PUMP �-- COOL AIR TO FLOOR �-- COOL AIR TO FLOOR - 40• COOL AIR TO FLOOR � — COOL AIR TO FLOOR COOL AIR TO FLOOR BY LM THOMAS LM THOMAS EXHAUST LOUVER IN GARAGE APPROVED WDH I CT-1S 1 SCALE: NONE TYP 4" CONN 8 " .. 1 1/2" IAC - 5S1 IAC -35 [AC -251 AC-1S 150,000 CFM MAXIMUM HVAC SCHE DATE 06.14.05 11.15.06 V ROOF OUTSIDE AIR SUPPLY AIR TO UNIT EF -1S EF -2S - - RETURN AIR TO SHAFT 5th FLOOR - SUPPLY AIR TO UNIT --a- RETURN AIR TO SHAFT 4th FLOOR SUPPLY AIR RETURN AIR TO SHAFT 3rd FLOOR 2nd FLOOR —P.- RETURN AIR TO SHAFT 1st FLOOR SUPPLY AIR TO UNIT RETURN AIR TO SHAFT SUPPLY AIR TO UNIT EXHAUST AIR FROM SHAFT EXHAUST AIR FROM SHAFT GARAGE FLOOR TO ATIC SOUTH TOWER REVISION AIR INTAKE AT PENTHOUSE 150,000 CFM MAX UNIT OUTSIDE AIR 1 By APPROVED DATE LOBBY LEVEL CEILING LOBBY LEVEL FLOOR GARAGE FLOOR COMMON SPACE FOR BOTH TOWERS OUTSIDE AIR INTAKE AT PENTHOUSE 150,000 CFM MAX AIR OUTSIDE AIR U- UJ J LO CC SUPPLY AIR SUPPLY EXHAUST AIR FROM AIR SHAFT TO SUPPLY AIR TO U RETURN AIR TO SHAFT 5th FLOOR UNIT 4th FLOOR SUPPLY AIR TO UNIT 3rd FLOOR 2nd FLOOR TO UNIT EXHAUST AIR FROM SHAFT —a- ROOF 1st FLOOR GARAGE FLOOR SCALE: NONE 8" 8 10" RETURN AIR TO SHAFT -� RETURN AIR TO SHAFT -a— SUPPLY AIR TO UNIT —a- RETURN AIR TO SHAFT RETURN AIR TO SHAFT APPROVED BY EF -1 N EF -2N DEPT. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DATE AC -4N I AC -3N AC -2N AC -1N HVAC SCHEMATIC OVERFLOW DRAIN; COOL AIR TO FLOOR EXHAUST LOUVER IN GARAGE 150,000 CFM MAXIMUM O RTH TOWER TITLE CT -1N DRAIN IN DECK CAPACITY CONTROL FAN DAMPERS COOL AIR TO FLOOR COOL AIR TO FLOOR �---- --� COOL AIR TO FLOOR --� COOL AIR TO FLOOR SUBTITLE MECHNICAL MASTER 1) UR CONSTRUCTION 11/17/06 HVAC SCHEMATIC REPLACE COOLING TOWER BUILDING 11 -14 LEGEND GENERAL NOTES REFERENCE DRAWINGS 11- 14 -M326 HVAC PIPING SCHEMATIC 11-14N-1M3 COMPOSITE HVAC PLAN - NORTH TOWER 11-145-1M3 COMPOSITE HVAC PLAN - SOUTH TOWER 41 CONSTRUCTION NOTES REPLACE EXISTING COOLING TOWER SPECIFIED AS CALLED OUT ON SHEET 11- 14N- RFM1OR WITH NEW COOLING TOWER AS CALLED OUT ON DRAWING 11- 14N- RFM14, USE INTERTIE TO SUPPORT AC-1N IF NEEDED AFTER CLOSING NEW ISOLATION VALVES INSTALLED ON 11 -14 MECHANICAL UPGRADE JOB. JOB MUST BE COMPLETED AND COOLING TOWER COMMISSIONED BEFORE THE NEXT COOUNG SEASON STARTS, NEW TOWER WILL EQUIPPED WITH VARIABLE SPEED DRIVE TO REPLACE ORIGINAL HIGH /LOW SPEED FANS AND SCROLL DAMPER DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED APPROVED APPROVED 0 0 14.05 06.14.05 DUWAVIISH CURRENT REVISION 556553 -01 SHEET JOB NO. DWG NO. SYMBOL M540 556553 -01 11- 14 -M540 JAN 1 6 2006 CI ATE- DATE COMP NO. 11.15.06 tCI 4 LID r.3 0 F BILL ❑F MATERIAL QUANTITY SYMBOL PART NUMBER DESCRIPTION 4 E1 - 9 BKDEPD1HAA4O DIFFERENTIAL PRESSURE SWITCH 3 -29# 4 E1 -61 RR2P IDEC RELAY 2PDT, 120 VAC 4 E1 -62 SREP -05 RELAY BASE 4 E2 -29 L70331165 SENSOR 500 OHM WITH WELL 2 D1 -11 MP909E1108 DAMPER MOTOR 3 - 13# EXT BILL P IE MATERIAL- QUANTITY SYMBOL PART NUMBER DESCRIPTION 2 C1 -32 305965 AIR GAGE, 1 -e' 0 TO 30 PSI 2 08 -4 RP7517B1016 ELECTRONIC /PNEUMATIC TRANSDUCER INTIIAL RELEASE TO PUM DI DO DI DO DI DO AO 22 31 23 32 26 35 25 THERMOSTAT 0 -150` F BY OTHERS SWITCH OPENS ON TEMPERATURE -------. INCREASE LOW WATER CUT -OFF SWITCH BY OTHERS OPENS ON LOW WATER —� HEATERS TO STARTER REVISION SECTION 1 FAN 1 LO FAN 1 I- II PUMP 1 SCROLL DAMP 1 COND PUMP P -3 COND PUMP P-4 TO ST ARTERS TYP 2 TYP 2 TO PUMPS ti � �Fe RNs Alk aj J J SZSZ mm;m DO DI DO DI 38 31 37 28 FAN 2 LO FAN 2 HI PUMP 2 SCROLL DAMP CONTACTOR 3g BY OTHER 556553-01 120/60/10 SECTION 2 TYP 2 BY LM THOMAs PAN HEATER CONTROL TO DAMP ACTUATOR TO STARTERS TO PUMP UNE VOLTAGE 460/3/68 TYPICAL PUMP /FAN WIRING DETAILS APPROVED WDH C6 CO CO CP CO CO co "Ok 7R 4 1te 1 4112 Elio ells aaa.,, mw a mmmmmm AO DO DI DO DI DO DI Al Al 26 36 27 34 25 33 24 48 51 COOLING TOWER CONTROL - NORTH NORTH WING COOLING TOWER DATE 11,15.06 • : CS REVISION Al AI 52 53 RED/1D. 418/2 ID/YEL 418/2 rr 1 E1 TYP4 C. NC : MOTOR STARTER IYP� AC COYIrILN COIF MIER TEMP ENIER1 C GI -mm � SHT. 1171)0 PANEL 'Am 11701 & i/o stall/Air DO DI DO DO DO & DI TO EXCEL PANEL TYP. BY DETAIL APPROVED N H HIGH C O I L- -�, TIME �Y-- -' -YP 4 DI DATE L3 L2 L1 LOW SPEED COIL STARTER (BY OTHERS) 3m 1..3 MT'DOM /S s DI T2 T3 ,. Tq :TMr. • Ts FAN MOTOR gar F?i4 MOTOR I — g /NG' NORTH COOLING TOWER CONDENSER WATER COOLING SYSTEM SEQUENCE OF OPERATION- ORIGINAL CONFIGURATION THE COOLING SYSTEM IS ARRANGED FOR 24 HOUR OPERATION INCLUDING DURING WINTER WEATHER. A PIPE WELL IMMERSION TEMPERATURE SENSOR AT THE SOUTH CONDENSER WATER SUPPLY COMMON LINE SIGNALS CONTROLS TO MAINTAIN THE WATER TEMPERATURE AT 85'F. AS THE WATER TEMPERATURE INCREASES, THE FOLLOWING SEQUENCE IS REGULATED: A. B. C. D. E. F. G. H. 77/78'F: 78/81'F: 78/82' F: 8O/83`F: 81/84' F: 82/85 82/86`F: 84/87' F: PUMP P -1 START, SECTION 1 SPRAY SLOW FAN 1 START, SECTION 1 FAN 1 CAPACITY DAMPER MODULATES, 0/100% SECTION 1 FAST FAN 2 START, SECTION 1 PUMP P -2 START, SECTION 2 SPRAY FAST FAN 1 START FAN 3 CAPACITY DAMPER MODULATES, 0/100% SECTION 2 FAN 4 START, SECTION 2 THE PONY MOTOR IS INTERLOCKED TO STOP WHEN THE FAST FAN STARTS. INTERLOCKS PROVIDE A TIME DELAY BETWEEN FAST AND SLOW START, AND PREVENT SIMULTANEOUS MOTOR OPERATION. CONDENSER PUMPS P -3 AND P-4 ARE ARRANGED FOR LEAD -LAG SEQUENCING BY THE EMS. A EITHER PUMP MAY BE SELECTED TO OPERATE AS LEAD OR LAG. B. THE LEAD PUMP OPERATES CONTINUOUSLY. C. THE LAG PUMP IS CYCLED TO OPERATE WHEN CONDENSER SUPPLY WATER TEMPERATURE EXCEEDS 86'F. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED APPROVED APPROVED ° 1017.06 10.17.06 SUBTITLE MECHANICAL MASTER EEL 1) REPLACE COOLING TOWER 11-14-M326 11- 14 -M328 11- 14 -M526 11- 14 -M540 CODE (.; ati 1) ISSUE FORC ONSTRUCTION 911/ 7/06 CONTROL DIAGRAM - NORTH COOLING TOWER BUILDING 11 -14 NA SEE SHEET 11- 14 -M328 FOR OVERALL SEQUENCES OF OPERATION FOR THE 11 -14N COOLING TOWER 2) SEE SHEET 11- 14 -E504 -EMCS FOR DETAILED LAYOUT OF BUILDING CONTROL SYSTEM PANEL 11- 14N -RFM3 11- 14 -M310 11- 14 -E504 -EMCS LEGEND GENERAL NOTES REFERENCE DRAWINGS COMPOSITE ROOF PLAN - NORTH TOWER CONTROL DIAGRAM -- 11 -14N COOLING TOWER HVAC PIPING SCHEMATIC CONTROL SEQUENCES 11 -14N COOLING TOWER HVAC PIPING DETAILS NORTH TOWER HVAC SCHEMATIC CMCS MBC -4 PANEL LAYOUT CONSTRUCTION NOTES THE CONTROLS CONTRACTOR SHALL PROVIDE A DETAILED DESIGN TO REPLACE THE EXISTING CONTROL INTERFACE FOR THE 11 - 14N COOLING TOWER WITH A NEW CONTROL INTERFACE FOR THE REPLACEMENT TOWER. THE NEW CC❑NTROL SCHEME SHALL SUPPORT USING TWO VARIABLE FREQUENCE DRIVES TO PROVIDE CAPACITY CONTROL OF EACH CELL OF THE NEW TOWER REPLACING THE CURRENT SCHEME OF A HIGH SPEED AND A LOW SPEED DAMPER PLUS A SCROLL DAMPER ON EACH TOWER CELL, DUWAMISH SHEET JOB NO. DWG NO. mow ` "? CURRENT REVISION 556553 -01 SYMBOL M555 556553 -01 11-- 14 --M555 DATE 11.15.06 COMP NO. g JAN 1 2008 PERT iI G .Nii-. t,? ,‘c t REPLACE COOLING TOWER REVISION TOP OF ROOF DECK 3'-4 3 556553 -01 f4• BY 1+ 1/2• MIN LM THOMAS SEE NOTES IN DETAIL PM1 O M556 OPERATING WT - 25220 LB EQ WEIGHT ° PER ISOLATOR O' -9' © COOLING TOWER 8' -10 1 2' ICT -1 NI SCALE: 1/4"-1'0 APPROVED WDH DATE PLYNTH ' 8' -10 1 2' $' -10 1 4' 141/2'4IIN . J COOLING TOWER ELEVATION VIEW LOOKING WEST r SCALE: 1/4"=1'0" 11.15.06 JCT- -1 N I, • 5'-91/2 PM10 M556 COOLING TOWER ELEVATION VIEW LOOKING SOUTH r3 PM10 M556 REVISION FEILD VERIFY: WOOD CURB BY OTHERS FLASHING & SEAUNG BY MECH CONTR SPRING I SOLA MASON SLR414 TION 6 TYP APPROVED DATE ArdifiWZAW • STRUCTURAL ENGINEER: -ROOF SUPPORT AT COOLING TOWER MUST NOT DEFLECT MORE THAN "R" WHEN LOADED - VERIFY PLYNTH HEIGHT, WIDTH, AND LENGTH ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED APPROVED APPROVED DATE 0.24.06 10.24.06 SUBTITLE MECHANICAL MASTER CONSTRUCTION NOTES Er. , , *'- v -�'�•j VO REPLACE COOLING TOWER BUILDING 11 -14 COL. X -X /X -X 11- 14N -PM1O 11- 14N -RFM10 11- 14N -M540 11- 14 -A555 11- 14 -A557 11-14-5503 Et>) rop cs› 11 -14N COOLING TOWER DETAILS SSE: FOR CONST RUCT iON I 1 /1 7106 DUWAMISH, WA LEGEND GENERAL NOTES REFERENCE DRAWINGS HVAC SYSTEMS - PENTHOUSE PARTIAL ROOF PLAN -- NORTH HALF HVAC SCHEMATIC BUILDING EXTERIOR ELEVATIONS ENLARGED PENTHOUSE PLAN NORTH SLAB PENETRATION DETAILS AFTER PIPING AND ELECTRICAL CONNECTIONS TO BUILDING SYSTEMS ARE BROKEN, UNBOLT THE COOLING TOWER BASE FROM THE CONCRETE SUPPORTS SHOWN INSPECT COOLING TOWER SUPPORT STRUCTURE FOR DAMAGE AND REPAIR PER DIRECTION FROM BOEING PLANT ENGINEERING. VERIFY DIMENSIONS OF NEW TOWER MATCH STRUCTURE PRIOR TO LIFTING TOWER FROM GROUND LEVEL TO PENTHOSE. BOLT NEW TOWERS VIBRATION ISOLATORS TO EXISTING SUPPORT USING HILTI QWIK BOLTS SIZED BE INSTALLATION PROCEDURE CURRENT REVISION 556553 -01 SHEET JOB NO. DWG NO. M556 556553 -01 SYMBOL 11 -14 -M556 JAN 1 6 2008 PE iMi CENT I DATE COMP NO. 11.15.06 1 SYM A B C D E 11 -14 EYEWASH 11-14 EYEWASH : . i d d INSULATE & HEAT TRACE EXPOSED PIPE 10" HYDRONIC RISER AS POSSIBLE CT -1N SIDE CT--1N SIDE BLDG SIDE 1 1/2" DRAIN REVISION NOTE: SEE ARCH PLANS SHT A -31 FOR RELIEF SIM TO IEF -1414 30"W x 30"H LOUVER BY OTHERS ADDED EF -14N AND MODIFIED FAN SYSTEM ADDED CONCRETE PLYNTHS, COND PIPE DTL ADDED KITCHEN EXHAUST FANS & DTLS 571035 571035 BY RD RD RD QQC QQC A 72'W x 721H 1 /— LOUVER BY OTHERS APPROVED LS LS DATE 03/10/88 04/06/88 10/27/88 12/14/93 2/10/94 I EF -13M SYM F G or re AS —BUILT 1 REPLACE COOLING TOWER REVISION INTAKE LOUVER BY OTHERS - INTAKE LOUVER BY OTHERS 60% FREE AREA Ti? UNO. 571035 556553 -01 BY QC LM THOMAS APPROVED LS WDH DATE 03/09/94 11.15.06 SCALE: 3/16 " =1 ' O n 3/4" CW DETAIL NORTH PENTHOUSE ENLARGED PLAN SEE DETAIL PM11 M526 ROUTE PIPING AT 2HR GWB ENCLOSURE SEE ARCH PLAN STAIR 'B" A -38 FUTURE URE PUMP LOCATION ?LA OE /N6 TOILET EXHAUSST, ., 721W x 36 LtiUfirErc BY OTHERS DRAIN FD B1r PLUMB CONTR 4-20 CONTROL COOLING TOWER RM 4 -20 CONTROL AUX CNTCTS C�iII�I; ACCEPTAB I LITY T1-115 DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRA CH C KED ENGINEER CHECKED APPROVED APPROVED ;4iPER CONTROLLE 9Y OTHERS TYP 01/ 14/88 SUBTE LE TITLE FOR CONSTRUCTION 1/11 7/06 CMCS CONTROLS - PENTHOUSE PLAN REPLACE COOLING TOWER BUILDING 11 -14N MECHANICAL MASTER COL. C —D/4 -8 j < rj>, PROVIDE AND INSTALL CONDUIT AND CABLE TO CONNECT VFDs AND TRANSFER SWITCH AUXILIARY CONTACTS Z A TO CMCS PANEL IN 3RD FLOOR MECHANICAL ROOM. DUWAMISH, WA LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES CURRENT REVISION 556553 -01 SHEET JOB NO. DWG NO. SYMBOL PE210 556553 -01 11- 14N —PE21 O DATE 11.15.06 COMP NO. JAN 16 2008 PEFI�vf "EEI`1TE AS -BUILT REVISION REPLACE COOLING TOWER 556553 -01 PARKING GARAGE 2 #18 TSP DUCT STATIC SPACE STATIC 2 #18 TSP DUCT STATIC SPACE STATIC 2 #18 TSP DUCT STATIC SPACE STATIC 2 #18 TSP DUCT STATIC SPACE STATIC SCHILLE LM THOMAS 11.15.06 SOUTH ALL WIRE SHOWN IS NEW RUNS. WIRE RISER IS IN ELECTRICAL ROOMS EXISTING WIRE IS NOT SHOWN. WIRE RISER IS THRU MECHANICAL ROOMS CAFETERIA 2 #24 TSP 2 #18 TSP DUCT STATI SPACE STAT 2 #18 TSP DUCT STATIC SPACE STATIC 2 #18 TSP DUCT STATIC SPACE STATIC �BOE /NG NORTH 4 #24 TSP 1 24 TSP TO INSIGHT 1 24 TSP TO FLN AT CMCS OFFICE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DRAWN SCHILLE CHECKED D.F. ENGINEER CHECKED APPROVED APPROVED CMCS TRUNK RISER DIAGRAM TITLE REPLACE COOLING TOWER BUILDING 11 -14 ELECTRICAL MASTER COL. X —X /X —X LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES 8 #18 TWISTED SHIELDED PAIR CABLES FROM MBCs TO PENTHOUSE COOLING TOWERS AND CONTROLS. h r CODE COMPLIANCE I DUWAMISH, WA CURRENT REVISION SYMBOL 556553 -01 SHEET E500 -EM Cs JOB NO. DWG NO. 556553 -01 COMP NO. 11- 14 —E500 —EMCS JAN 16 2008 PERMIT CENTER DATE 11.15.06 DUW.1114.N.CLNG.TWR.CND.P2.SS 004 0 01 01 (TWR SPRAY PMP 2 ) ON MBC -40 ENCLOSURE W /STYLD DR —N— NONE DUW.1114.N.CLNG.TWR.CND.P1.SS 004 0 01 02 ( SPRAY PMP 1 ) ON 1 —N— NONE DUW.1114.N.EMPOWER.ALARM 004 0 02 01 (EMER POWER ) NORMAL —N— NONE DUW.1114.N.CLNG.TWR.CND.P3.SS 004 0 03 01 (BLDNG COND PMP 3) ON LANDIS & STAEFA —N- NONE DUW.1114.N.CLNG.TWR.FAN1.FSS 004 0 05 02 (CLG TWR FAN FSS ) SLOW PTM6.2Q250 -M —N— NONE DUW.1114.N.CLNG.TWR.FAN2.FSS 004 0 07 02' (CLG TWR FAN FSS ) STOP 2 ADP, 0 -20 PSI W /MANUAL OVRD —N— NONE DUW.1114.N.RELSHAFT,FAN2.SS 004 0 11 01 (RELIEF FAN 2 SS ) ON —N— NONE DUW.1114.N.RELSHAFT.FAN1.SS 004 0 11 02 (RELIEF FAN 1 SS ) ON —N— NONE DUW.1114.N.CLNG.TWR.CND.P4,SS 004 0 13 01 (BLDG COND PMP 4 ) ON —N— NONE DUW.1114.N.EXHAUST.ELEV.SS 004 0 15 01 (FAN START STOP ) ON —N— NONE DUW.1114.N.00CUPANCY.FLOOR5.SW 004 0 16 01 (MOMENTARY P.B. ) OFF —N— NONE DUW.1114.N.00CUPANCY.FLOOR4.SW 004 0 16 02 (MOMENTARY P.B. ) OFF —N— NONE DUW.1114.N.CLNG.TWR.CND.P5.SS 004 0 17 01 (EM BLD CND PMP 5) OFF —N- NONE DUW.1114.N.CLNG.TWR.CND.P6.SS 004 0 17 02 (EM TWR SPRAY P6 ) OFF —N— NONE DUW.1114.N.00CUPANCY.FLOOR3.SW 004 0 18 01 (MOMENTARY P.B. ) OFF —N— NONE DUW.1114.N.00CUPANCY.FLOOR2.SW 004 0 18 02 (MOMENTARY P.B. ) OFF —N— NONE DUW.1114.N.00CUPANCY.FLOOR5 004 0 19 01 (MODE COMMAND ) OCCUP'D — NONE DUW.1114.N.00CUPANCY.FLOOR4 004 0 19 02 (MODE COMMAND ) OCCUP'D — NONE DUW.1114.N.RELSHAFT.PRESS 004 0 20 02 (RELIEF SHFT PRES) —0.284 IN H2O —N— NONE DUW.1114.N.00CUPANCY.FLOOR3 004 0 21 01 (MODE COMMAND ) OCCUP'D —N— NONE DUW.1114.N.00CUPANCY.FLOOR2 004 0 21 02 (MODE COMMAND ) OCCUP'D —N— NONE DUW.1114.N.KWMETER2 004 0 22 01 (KW METER ) 463 KW —N— NONE DUW.1114.N.KWMETER1 004 0 22 02 (KW METER ) 331 KW —N— NONE DUW.1114.N.RELSHAFT.FANI.IGV 004 0 27 01 (VANE OUTPUT ) 7.19 PSI —N— NONE DUW.1114.N.CLNG.TWR.BLDG.RTEMP 004 0 28 01 (BLDG CND RET TMP) 85.3 DEG F —N— NONE DUW.1114.N.CLNG.TWR.BLDG.DTEMP 004 0 28 02 (BLDG CND SUP TMP) 82.6 DEG F —N— NONE DUW.1114.N.RELSHAFT.FAN2.I0V 004 0 29 01 (VANE OUTPUT ) 7.19 PSI —N— NONE DUW.1114.N.CLNG.TWR.VOLDMPR1 004 0 31 01 (VOLUME DMPR ) 15 PSI —N— NONE DUW.1114.N.OSAT 004 0 32 02 (OUTSIDE TEMP ) 61.69 DEG F —N— NONE DUW.1114.N.CLNG.TWR.VOLDMPR2 004 0 33 01 (VOLUME DMPR ) 0 PSI —N— NONE DUW.1114.N.CLNG.TWR.CND.RTEMP 004 0 34 01 (LEAVING TWR TEMP) 79.8 DEG F —N— NONE DUW.1114.N.CLNG.TWR.CND.DTEMP 004 0 34 02 (ENTERING TWR TMP) 82.9 DEG F —N— NONE DUW.1114.N.VAULT.1EMP 004 0 36 01 (VAULT TEMP ) 68.49 DEG F —N— NONE CONTROL DEVICE QTY DESCRIPTION PRODUCT NUMBER MANUFACTURER MBC- -4 1 MBC -40 ENCLOSURE W /STYLD DR 545 142 LANDIS & STAEFA 1 ADRESS KEYS 001 -016 545 040 LANDIS & STAEFA 1 ADRESS KEYS 017 -32 545 041 LANDIS & STAEFA 1 ' ADRESS KEYS 33 -48 545 042 LANDIS & STAEFA 1 M -BUS POWER MODULE 545 703 LANDIS & STAEFA 1 CTLR MODULE P2 W/ 4.0MB 545 715 LANDIS & STAEFA 2 2 Al 4 -20 MA PTM6.21420 LANDIS & STAEFA 8 2 DO, CONTACT W /MANUAL OVRD PTM6.2Q250 -M LANDIS & STAEFA 4 4 DI DRY CONTACT PTM6.4020 LANDIS & STAEFA 4 2 ADP, 0 -20 PSI W /MANUAL OVRD PTM6.1 PS120 -M LANDIS & STAEFA 4 2 AI, 1K PLATIMUM RTD PTM6.2P1K LANDIS & STAEFA A 01 On QN 0- a te' O Q N O Oi O Q 0 Q N Or On oN 0- O* O Q N O - O O O O C° ON O® Q Oo ON a® Our ON O° O� 0 a 3 ON O % Q� Orn ON � Ow O °3 O Q w O O O O% O Oco ON O% Ou r O O O% O SCALE AS —BUILT REPLACE COOLING TOWER 1 DUW.1114.N.CLNG.TWR.CND.P2.SS TWR SPRAY PMP 2 2 DUW.1114.N.CLNG.TWR.CND.P1,SS TWR SPRAY PMP 1 1 DUW.1114.N.CLNG.TWR.CND.P3.SS BLDNG COND PMP 3 REVISION 1 DUW.1114.N.CLNG.TWR.FAN1.FSS CLG TWR FAN FSS 2 DUW.1114.N.CLNG.TWR.FAN1.FSS CLG TWR FAN FSS 1 DUW.1114.N.CLNG.TWR.FAN2.FSS CLG TWR FAN FSS 2 DUW.1114.N.CLNG.TWR.FAN2.FSS CLG TWR FAN FSS 1 DUW.1114.N.RELSHAFT.FAN2.SS RELIEF FAN 2 SS 2 DUW.1114.N.RELSHAFT.FAN1.SS RELIEF FAN 1 SS 1 DUW.1114.N.CLNG.TWR.CND.P4.SS BLDNG COND PMP 4 1 DUW.1114.N.EXHAUST.ELEV.SS FAN START STOP 0.04.0.015 1 DUW.1114.N.CLNG.TWR.CND.P5.SS EM TWR SPR PMP 5 2 DUW.1114.N.CLNG.TWR.CND.P6.SS EM BLD CND PMP 6 1 DUW.1114.N.RELSHAFT.FANI.IGV VANE OUTPUT 1 DUW.1114.N.RELSHAFT.FAN2.IGV VANE OUTPUT 1 DUW.1114.N.CLNG.TWR.VOLDMPR1 VOLUME DMPR 1 DUW.1114.N.CLNG.TWR.VOLDMPR2 VOLUME DMPR MODULAR BUILDING CONTROLER 556553 -01 BY DJF LM THOMAS APPROVED WDH 0.04.0.001 0.04.0.003 0.04.0.005 0.04.0.007 0.04.0.011 0.04.0.013 0.04.0.017 0.04.0.027 0.04.0.029 0.04.0.031 0.04.0.033 DATE 11/97 11.15.06 REVISION E504 O¢ On ON O- O* O ON O r 0 O� ON o- O O Oi Oo ON O cb Ot o ON Oco O O N Occ O Ln 0* OM ON O 0 OM ON O' O* O n ON 0 ` - 0 0 3 ON Q ) O ON O °3 O" O* O� Q N OT O* OM aN Or Q cc Or Q cc Occ O O Q Occ acc Q uc 1 DUW.1114.N.EMPOWER.ALARM 2 DUW.1114.N.CLNG.TWR.CND.P1.SS 3 DUW.1114.N.CLNG.TWR.CND.P4.SS 4 DUW.1114.N.CLNG.TWR.CND.P3.S5 1 DUW.1114.N.CLNG.TWR.FAN2.FSS 2 DUW.1114.N.CLNG.TWR.CND.P5.SS 3 DUW.1114. N.CLNG.TWR.FAN 1.FSS 4 DUW.1114.N.CLNG.TWR.CND.P6.SS EMER POWER TWR SPRAY PMP 1 BLDNG COND PMP 4 TWR SRAY PMP 3 0.04.0.002 . TWR . FAN.: FSS. TWR SPRAY PMP 1 CLG TWR FAN FSS . BLDG COND PMP 4 0.04.0.004 3 DUW.1114.N.RELSHAFT.FAN2.SS RELIEF FAN 2 SS 4 DUW.1114.N.RELSHAFT.FAN1.SS RELIEF FAN 1 SS 3 DUW.1114.N.CLNG.TWR.CND.P2.55 TWR SPRAY PMP 2 2 DUW.1114.N.RELSHAFT.PRESS RELIEF SHFT PRES 1 • DUW.1114.N.KWMETER2 KW METER 2 DUW.1114.N.KWMETER1 KW METER 1 DUW.1114.N.CLNG.TWR.BLDG.RTEMP BLDG CND RET TMP 2 DUW.1114.N.CLNG.TWR.BLDG.DTEMP BLDG CND SUP TMP 2 DUW.1114.N.OSAT OUTSIDE TEMP 1 DUW.1114.N.CLNG.TWR.CND.RTEMP LEAVING TWR TEMP 2 DUW.1114,N.CLNG.TWR.CND.DTEMP ENTERING TWR TMP 1 DUW.1114.N.VAULT.TEMP VAULT TEMP BY APPROVED POWER MODULE CONTROLER MODULE PANEL 04 DATE 0.04. 0.04.0.008 0.04.0.020 0.04.0.022 0.04.0.028 0.04.0.032 0.04.0.034 0.04.0.036 gLArArcwAribO' MBC -4 BILL OF MATERIAL SCALE: NONE MBC -4 CABINET POINTS LIST SCALE: NONE ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE tWWN D. FREEMAN CHE ENGINEER D. FREEMAN CHECKED APPROVED APPROVED 41) E504EMCS Aft E504EMCS DATE /97 SUBTITLE TITLE ELECTRICAL MASTER CMCS - MBC -4 PANEL LAYOUT REPALCE COOLING TOWER BUILDING 11 -14 COL. X—X /X —X GENERAL NOTES 1) MBC PARTS TAKE OFF BASED ON ORIGINAL INSTALLATION. REVISIONS AND UPDATES SHOULD BE PROVIDED AS REDLINES TO EACH REVISION MODE 2) MBS 4 POINTS LIST WAS GENERATED 11 -06 -2006 AND SHOULD BE UPDATED AS A REDLINE WITH EACH REVISION c "' - '%-i-kecr 4 Ne' -44 NeeeThoegg - ;4v#Th m‘ 11- 14 —E500 —EMCS CMCS TRUNK RISER 11-14—M310 CONTROL DIAGRAM 11 -14N COOLING TOWER 11- 14 —M326 CONTROL SEQUENCES 11 -14N COOLING TOWER 1 ) LEGEND REFERENCE DRAWINGS CONSTRUCTION NOTES THE CONTROL SYSTEM CONTRACTOR SHALL DEVELOPE A DETAILED DESIGN INCLUDING A BILL OF MATERIAL FOR THE REVISING MBC -4 TO SUPPORT THE NEW COOLING TOWER. THE CONTROL SYSTEM CONTRACTOR SHALL ALSO PROVIDE REVISED SYSTEM GRAPHIC AND CABINET PROGRAMMING AS REQUIRED TO OPERATE THE NEW COOLING TOWER .F. JAN 16 2008 PER; LENTEI': !3SUE FOR CONSTRUCTION 1117106 DUWAMISH, WA CURRENT REVISION 556553 -01 E504 -FMCS JOB NO. DWG NO. 556553 -01 SYMBOL A 11- 14— E504 —EMCS DATE 11.15.06 COMP NO. XFNIR RT1 PANEL LOAD RL1A HTG. RL1 B KT, MECH. KITCH EQ. RP1A KITCH EQ. RP1B KITCH EQ. RP1C KITCH EQ. RP1D KITCH EQ. RESTAURANT SYSTEM EQUIPMENT SCHEDULE NORTH TOWER SIZE # POLES 600A 600A 225 KVA 400A 400A 400A 400A 42 42 42 42 42 42 VOLT L,OOATION 480Y/277 KITCH MECH RM 480y(277 KITCH MECH RM 4801/120/208 KITCH MECH RM 208Y/120 KITCHEN 208Y/120 KITCHEN 208Y/120 KITCHEN 208Y/120 KITCHEN • A CJ 7) SYMBOLS GENERAL NOTES 1) ALL CONDUIT TO BE 1/2' E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 'A" PHASE (LEFT BUS IN PANEL) BLACK "B" PHASE (CENTER BUS IN PANEL) RED PHASE (RIGHT BUS IN PANEL) BLUE NEUTRAL WHITE EQUIPMENT GROUND GREEN 4) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 5) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -IN CIRCUIT BREAKERS ON BUSWAYS. 6) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. DYMO LABEL ALL RECEPTACLES, J- BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 277/480V BROWN ORANGE YELLOW GREY CONSTRUCTION NOTES: NEW 1 -1/2 ". 3 #1/0 FROM NXX /1,3,5 TO N. PENTHOUSE. PROVIDE AND INSTALL NEW 100A 6 -POLE DOUBLE THROW SWITCH. USE CUTLER HAMMER #DT663URK WITH AUXILIARY CONTACTS. #DS200EK2. PROVIDE AND INSTALL (2) NEW 50 HP VFD'S FOR COOLING TOWER FANS. USE ALLEN BRADLEY POWERFLEX 400. PROVIDE AND INSTALL (2) NEW 100A, FUSIBLE DISCONNECT SWITCHES G.E. #T1-13561 R. REMOVE EXISTING CONNECTIONS TO COOLING TOWER FANS. REROUTE POWER FROM ONE MCC BUCKET TO TRANSFER SWITCH FOR NORMAL POWER TO FAN MOTORS. ISSUE FOR CONSTRUC ION 11117106 F JAN 162008 C.ENTEb SYM A B C REVISION PROVIDE DUWAMISH UPS J#570590 CAS ITAR HOTEL CENTER J#150685 -00 REPLACE COOLING TOWER J#556553 -01 A.MORCAN SSH SSH HY APPROVED CAS DATE 6/8/06 1D/26/06 SYM REVISION 6Y APPROVED DATE FACILITIES DEPARTMENT ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN BY C 'MELTED LL ENGR. CHECKED APPROVED APPROVED DATE 05 -92 SUBTITLE ONE LINE DIAGRAM TITLE ELECTRICAL MASTER BUILDING 11.14N COL LAST REVISION SYMBOL SHEET E4A JOB NO. 00000 NBF DWG NO. E11.14N -E4A DATE 10/19/06 OF COMP NO. SXT #2 CU- 1 1/2"-4 #2 THHN, Cu .70A . ... .. • ; :•• ••••• 150A SEATS 1"-3#8 CU (319) 30 KVA 1 1/2"-4 #2/0 THHN, Cu 225A/125A 125A/80A SSWBD-1 125A 400A 400A . 400A 3 1/2"—q500 MCM THWN,CU 3 1/2"-4#500 MCM THWN,CU 1 1/2"-4 #2/0 THHN, Cu (320) 1"-4 #4 THHN, Cu 1 1/2"-3#1 Cu (319) SXT 75 KVA • #2 CU (320) (2) 3"-4#350 MCM,CU (321) (323) 400A/300A 125A/60A 150A/125A (305) (317) 400A SATS 1 1/4"-3#2THHN Cu (318) (329) CAC-3S 400A/400A • CAC-4S (330) AC-1 S—D4.5 #8 THHN, CU (ON S. 4TH FLR.) c2I1 1/2, 3 #10 CU (333) SXTN 30KVA (334) 1 1/4"-5#2THHN,CU (335) 100A/100A #8 Cu 100A UPS POWER 0 : . :...• : (331) (332) .. . : :'•• ••• . ....... , .. ,• •'• ••• • •" • "• • • : ; • ; • . •••• • .' ' (340) STC 1 .•:••••:..::•••: STU 1 75KVA : : 75KVA 200A 2",4#3/0 & 1#4 GND. 1-1/2" 3 #2 THHN THHN CU. NEUTRAL, 1#4 THHN CU. GND. SXU 600A/600A (339) • 125A 225A (341) /200A 100A/100A E DIAGRA (325) 1/4"-3#2THHN Cu , (306) 600A 600A 3 1/2"-4#500 MCM THWN,CU (2) 3"-4#350 MCM THWN,CU (324) (2) 3"-4#350 MCM 600A (354) UPS ATS 3"-4#350 MCM THWN,CU SXE 600A/600A 3"-3#500 MCM THWN,CU 1"-3 #4 THHN, CU 600KW GENERATOR W/INTERNAL LOAD BANK :.,•• : ••: •,• • . • : • • :. .•• : :...• •• • •'• : . . . . „.. SXG & 1#2 THHN CU. • • • :•.•: : 75KW GENERATOR W/INTERNAL LOAD BANK 3 1/2"-4#500., MCM THWN,CU 1 1/2"-4 #2 THHN, CU (366) (367) (365) 70A : ... NXTD .......... 30KVA • #8 CU 100A/60A NEATS 150A 1 1/2"-4 #2 THHN, CU A : , 1/2"-3#1O Cu NLOPS 80A 480Y/277V 44 CAS LTS 480Y/277 • NOPS1 225A 208y/120 N6f • 100A 208y/12D 1 1/2"-4 #2 THHN, CU 3 1/2"-4#500 MCM TH (325) SXTU : : 15KVA (327) 1 1/4" 4 #6 THWN,CU--- (328) ...••••••. •.• .•••••• 100A/60A • . #8 CU NSWBD-1 (106) 125A 400A •• 125A.: 3 1/2"-4#500 MCM THWN,CU (124) 410 CONSTRUCTION NOTES NEW TRANSFER SWITCH AND WI) FOR NORTH COOLING TOWER. ]> NEW FEEDER TO COOLING TOWER FANS. N,CU (125) 400A/400A 125A/100A Tht, (132) (133) (134) •••••.•.• 125A/60A ATS 400A 1 1/2"C 3 #1/0 THWN, Cu 1 1/4" 4 #4 CU (130) .• •• • ..• • • ... 400A/300A (128) #10 • NXT1 NXT 15KVA 15KVA #8 CU (129) #8 CU 100A/60A :.. • : • . • • '• (2)2 1/2"C 4 #1/0 THWN, CU (127) 1 NMCC : 100A 240V 30 l ' 4 " - -3/4"-4 #6 THWN, CU (126) 100A/100A JAN 162008 CENTER ISSUE FOR, CONSTRUCTION 11 /17/06 1) 2) NTC1 SYMBOLS (XXX) INDICATES BUS NUMBERS GENERAL NOTES XFMR NXT XFMR ALL CONDUIT To BE 1/2" E.M.T. UNLESS OTHERWISE NOTED ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. "A" PHASE (LEFT BUS IN PANEL) "B" PHASE (CENTER BUS IN PANEL) "C" PHASE (RIGHT BUS IN PANEL) NEUTRAL EQUIPMENT GROUND 120/206V 277/480v BLACK BROWN RED ORANGE BLUE YELLOW WHITE GREY GREEN 4) ALL NEUTRAL WIRES TO SYSTEM FURNITURE POWER POLES SHALL BE A MINIMUM OF #10 COPPER IN SIZE. 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 7,? ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, I NCLUDING PLUG—IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 8) DYMO LABEL ALL RECEPTACLES, .J—BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 9) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. PANEL NXL NXP XFMR NXET XFMR PANEL SXEL SX7 SXEP PANEL NXEL NXEP PANEL LOAD LOAD LGT,COMP MISC MISC NDP1 COMPUTER NCP1 COMPUTER NCP2 COMPUTER NCP3 COMPUTER NCP4 COMPUTER NCP5 COMPUTER COMPUTER STANDBY SYSTEM GENERATOR = 600KW, 480Y/277V,3PH,4W EQUIPMENT SCHEDULE NORTH TOWER LOAD SIZE #POLES LGT,COMP 125A 42 MISC 15 KVA !Also 100A 42 EMERGENCY SYSTEM GENERATOR — 75KW, 480y277V,3PH,4W EQUIPMENT SCHEDULE NORTH TOWER LOAD SIZE #POLES LGT,COMP 125A 42 MISC 15 KVA -- MISC 100A .42 SIZE 125A 30 KVA 100A SIZE 800A 100 225 225 200 200 225 KVA SOUTH TOWER #POLES NORTH TOWER # POLES VOLT LOCATION 480Y( 277 S.ELECT RM 480//120/208 S.ELECT RM 208 /120 SEL RM VOLT 480Y/ 480 /120/208 20 /120 VOLT 42 480Y/ 277 -- 480//120/208 42 208Y/120 LOCATION S.ELECT RM S.ELECT RM S,ELECT RM LOCATION S.SWBD RM S.SWBD RM S.SWBD RM TENANT IMPROVEMENT EQUIPMENT SCHEDULE VOLT LOCATION 18 208Y/120 I/O COMP RM 42 208Y/120 FAN COMP RM 42 208y/12D I/O COMP RM 42 208Y/120 I/O COMP RM 42 208Y/120 I/O COMP RM 42 208Y/120 I/O COMP RM 480//120/208 I/O COMP RM SYM R K L D E REVISION CAS ITAR HOTEL CENTER 4150685-00 DUW ELEC GENERATOR 4150687-01 REPLACE COOLING TOWER 4556553-01 INSTALL PANEL/RECEPTS #D79002221 REMOVE/INSTALL RECEPTS. D79G0962 SSH SSH SSH BY COOK JRC COOK JRC APPROVED DATE 6/ 9/28/06 10/26/06 4/16/97 8/8/97 SYM REVISION L REV. POWER S. DATA CTR. D79G1249-2 G H SWITCH UPGRADE J#556726-02 CAS OPS CENTER 4150550-00 VOIP POWER J# 565503-00 SSH J GOLDCARE OFFICE EXPANSION 150686-00SSH BY COOK SSH SSH APPROVED JRC CAS CAS DATE 1/15/98 7/22/05 9/8/05 3/16/06 4/20/06 Alit€74EZAW FACILITIES DEPARTMENT ACCEPTABILITY THIS DESIGN AND/OR SPECIF1CA11ON IS APPRovED APPROVED BY DEPT. DATE DRAWN BY RMYHRE CHECKED ENGR. CHECKED APPROVED APPROVED DATE 07-10-90 SUBTITLE UPS & EMER POWER 1-LINE TITLE ELECTRICAL MASTER BUILDING 11-14 COL LAST REVISION NBF DWG NO. SYMBOL L SHEET E5 JOB N°150686-00-00 El l-14—E5 DATE 10/26/06 OF COMP NC. SYM A B W "i D ( 800 KW ST DIES ) GEN CONTRO L) FEEDER ST OF ELECTR INTO MEN' FOLLOW S r"` EL GIERA R DBY TOR ______ : _, - 1 - 1 /2" RGS, 4#2 EMERGENCY 1" RG$, 4#12 CONTROL CONDUIT 1 NAT STC2 UP TO 1ST MECH GOES INTO; THE CEILING AL VAULT. STRAIGHT UP RESTROOM CEILING. (TO 1ST FLR. PLAN. REVISION R BOX ii Z CO vrk (} PROVIDE DUWAMISH UPS — REMOVE 300KW GENERATOR J #570590 PROVIDE DUWAMISH UPS — INSTALL 600KW GENERATOR J #570590 DUW ELECTRIC GENERATOR J #150687 -01 EXPANSION JOINT FITTING " CONTROL CONDUIT 'F4Q NATS L X BY SXL A. MORGP A. MORGt SSH N N APPROVED / EXPANSION JOINT FITTING 9/2$/06 \ \ .. ' ' yN J— .,\ ,., �), •\' 3 ` ! 'f' 1 i r' Y' ` it , t — - FEEDER TO STC2 GOES FR OF SXL INTO CLOSET ACR FOYER UP TO 1ST FLOOR TO FOLLOW ONTINUE TO .1 S, 44- f, BOX M SUB —FEED � S FREIGHT ECHANICAL RM. FLR. PLAN SOUTH. REVISION BY APPROVED Are DOTE {7{ 1 -1/2' RGS 4 DA BUS . NSWBD -2 :NOBD -1 FACILITIES DEPARTMENT LOCATION OF STANDBY POWER PANEL NXX IN PARKING LEVEL OF DUWAMISH. 1 ,i P y • APPROVED BY C f ` R'cTiCI NOTES - INSTALL t .5KW 'GENERATOR ONthXISTING PAD N T TO BUIL WIRE FROM GEN RATOR DISTRI UNION PANEL T 4—BOX AND PROVIDE TPANS N JOINTS W TRANSITIONIN ETWEEN T 'E \ PROVIDE ARID INST L J —BOX AN t` 2) 70A, 3 —P IN NORTH ND SO . ,•_r,F1C' LIGHTI N BACK TO PROVIDE Air IN PROVIDE A IN PROVIDE AN IN ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED '1 INSTAL 1 -1 /2" CND D 5TR I BU 4 ' • '' c--4- , 1D e \ 1 ` PFA IDE AND 1INSTALL ITOMATRt TRANSFER SWITCHES H MODE 2000 CONTRJL. PRO E AND INSTALL 1 —1t, ,2" - s' 1 - IT & WIRE ) 3 —POL G . � ` 'd'N — 3 —POLE, RS. tr oi USE G.E., TED BREAK 'I'S IN NEM FRO , GENERPTOR s 70A' BREAKEf3 EN( LOSURESs. I t / • EN CLO N. A D S. LECTRIC L or DEPT. DATE A KER NCLO RES Tk TRA • FER STALL 1 -1/2 } RGS C NDUIT ND 4 i1 WIR FR M NEW R SWI rEID NEL NXL FFtp M N BW EMERGENCY TRANS FE SWIT H SOU NXX. D G CRESSWELL CHECKEb FAOR- CHECKED APPROVED APPROVED DATE 02 -01 -93 TALL NEW 277/4OV 4NEL. P TALL NEW 30KVA, •480 ITO 208Y TALL 1" RGS CON.JIT ND 3 # Sl"A L 1 -1 /2" RCS Cd JD REFERENCE NOTES SUBTITLE 1) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 2) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS BOO VOLTS OR LESS. 120/208V 277/480V A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN 3) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 4) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG —IN CIRCUIT BREAKERS ON BUSWAYS. 5) DYMO LABEL ALL RECEPTACLES, J— BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 6. POST REVISED PANEL SCHEDULES UPON JOB COMPLETION. SEATS NEAR GENERAL NOTES SOUTH EMERGENCY AUTOMATIC TRANSFER SWITCH NORTH EMERGENCY AUTOMATIC TRANSFER SWITCH 0 BE G.E. 'YPE\ AEC TRANSFORM. C. E. #9T23B S FROM NE PANEL SX IT AND 4-\, 1 0 WIRES FRO I\ 1. SEE DWG. 1 1.14S -0E2 & 11.14N -0E2. FOR ADDITIONAL INFORMATION ON NATS /SATS EMERGENCY FEEDERS. 2. SEE DWG. 3.800 —E5 FOR 300KW GENERATOR INSTALLATION. 480Y1277 VOLT POWER MAIN FEEDERS AND PANELS BUILDING 11 -14 -0 ELECTRICAL MASTER COL A— T/1 -18 CONDUIT & :RE-AKER NCLOSURES. RES. MOUNT EAKER ENCLOSURES 15 ENCLOSUR H (N CE. R NEW SHEET DWG W ITCH S ES. TS) ITO EXISTING MOVE% OLD FEEDERS EN LOSU. LAST REVISION OE7 JOB NO. 00000 ECRIC TRANSFER YI H (SEAT* SFER SWITCH NEATS). PROVIDE AND IN ILL 1 -1 /4" RGS COND` 113 AND S s � - �w+.,�,.e�� �o,,,r� " ` w� J ''w Y .c�'e ry ..,,�, , r� ti. +�.,.��''�_ .� ,.,�" ter. A' S � ��"'+ �h,..�,s✓ ''�� ��'�...w'd` ''c..-_r"� `�w�'iw��'R'+�` JAN 16 2008 P = a 86 CENIEI- ISSUE FOR CONSTRUCTION 09128/06 SYMBOL EL. NO. 11 14 - 0E2 /SMALL DATE 9/28/06 OF COMP NO. O CD a 13,15,17 1"-6 18, THHN C MOTOR STARTER SIZE "00 ", 120V COIL TO CONTROL EF 1 4tI TO PAL NXPH 480VAC REVISION R REPLACE COOLING TOWER J4556553 -01 NE 8,10.12 PANEL NE MOTOR STARTER WIRING DIAGRAM 3 HP,480V, 3 *, EXH. FAN MOTOR STARTER SIZE "0 ", 120V COIL TO CONTROL EF -36N 10/26/06 1,3,5 NE -1,3, 5,7,9,11 -3 THW,C r NMC re 30, EXH. FAN ;;SOR 'CONN 50' ;-ra. :..5'KW15 uP HIGH • :• ,: PAN Lt. SPEE=D , r.TR SPED / ASKigle7Air FACILITIES DEPARTMENT 3 HP,480V 3'4, COMPR ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY APPROVED CONSTRUCTION NOTES REMOVE EXISTING CONNECTIONS TO COOLING TOWER FANS AND PAN HEATERS. REMOVE EXISTING DISCONNECT SWITCH FEEDING PAN HEATERS. REMOVE COOLING TOWER FAN DISCONNECT SWITCHES AND ALL LOAD SIDE CONDUITS. SEE PE110 FOR NEW INSTALLATION. LEAVE CONDUIT AND WIRE FROM MCC TO CT ROOM. DATE 06 -28 -90 SUBTITLE ELECTRICAL MASTER COL GENERAL NOTES 1) ALL CONDUIT TO BE 1/2' E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN 4) ALL NEUTRAL WIRES TO SYSTEM FURNITURE POWER POLES SHALL BE A MINIMUM OF #10 COPPER IN SIZE. 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 6) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 8) DYMO LABEL ALL RECEPTACLES, J- BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 9) ALL VAV FAN MOORS TO BE F.H.P. AS NOTED, 277V, 1 . 10) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 11) ALL TERMINAL UNITS RATED 480V,3 SHALL HAVE 30 AMPS /3P, 4W SAFETY SW WITH 20 AMP FRS SES. LEGEND REFERENCE NOTES: SEE DWG. 11.14N -0E2, 480Y /277VOLT POWER MAIN FEEDERS AND PANELS. 277/480 VOLT SYSTEM BUILDING 11 -14N ISSUE FOR CONSTRUCTION 11r'S7;06 REMOVAL LAST REVISION PE11GR JOB NO. 00000 JAN 16 2008 Pau CENT.- DATE 10/26/06 COMP NO. SYM A C REVISION 1 1 /2HP,480V, EXH. FAN TO PAL NXPH 4-80VAC PROVIDE DUWAMISH UPS J #570590 EC-111 1 40 HP,480V, 25 HP,480V, 30, ELEV CONN 3O, ELEV CONK 7,9,11 EC -2N 40 HP,480V, 30, ELEV CONN MOTOR STARTER SIZE "O0 ", 120V COIL TO CONTROL EF -1 U REPLACE COOLING TOWER J #556553 -01 BY A.MORGAN SSH [EC --3N #12 • IEC -4N 40 HP,480V, 30, ELEV CONN #12 I NE- 8,10,12 APPROVED 3 / 4 " -3 8 �� 1 1/4"-3 3 #8, THH CU MOTOR STARTER WIRING DIAGRAM : 1,3,5 NE -1,3, 5,7,9,11 3 HP,480V, 30, EXH. FAN MOTOR STARTER SIZE "0 ", 120V COIL TO CONTROL EF -36N DATE 10/26/06 SYM r r 4, 480V CPT OLs REVISION BY APPROVED 1"-3 #4 THW, P -3N NORTH PENTHOUSE PLAN DATE AO P APA e7 FACILITIES DEPARTMENT NMCC NMC 40 HP,480V, 30, CIRCULATING PUMP 1"-3 4, THW,CU 40 HP,480V, 30, SPRAY PUMP P--2N 40 HP,480V, 30, SPRAY PUMP • 3 - NIw;480v; - 30, EXH. FAN P —N6 1/2"C,3#10 THHN ,CU NXPH /7,9,11 10 HP,480V, 30, SPRAY PUMP 3 HP,480V, 3'i, COMPRE SOR CONN 1 5HP,4 30, CIRCU T G PUMP PE110 PE110 501 5'KW HIGH PAN SPEED HTR 1 1/4 " - #2,THW,C N #12 50' HP 5 K HIGH PAN SPEED HTR PE110 PE110 APPROVED BY • ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN BY RMYHRE CHECKED APPROVED APPROVED DATE 06 -28 -90 G \IERA_ NOTES 1) ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN 4) ALL NEUTRAL WIRES TO SYSTEM FURNITURE POWER POLES SHALL BE A MINIMUM OF #10 COPPER IN SIZE. 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 6) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG —IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND £3. 8) DYMO LABEL ALL RECEPTACLES, J— BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 9) ALL VAV FAN MOORS TO BE F.H.P. AS NOTED, 277V, 1 . 10) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 11) ALL TERMINAL UNITS RATED 48OV,3 SHALL HAVE 30 AMPS /3P, 4W SAFETY SW WITH 20 AMP FRS SES. LEGEND FAN, 480V, 30/ FAN, 277V, 10/ r CALIF' O \: - BUILDING FLOOR SLABS ARE PRE TENSIO NED. X -RAY ALL LOCATIONS PRIOR TO DRILLING, PENETRATING OR ANCHORING TO FLOOR SLABS. SUBTITLE TITLE s <)--) PROVIDE AND INSTALL NEW 100A 6 —POLE DOUBLE THROW SWITCH. 2 CONSTRUCTION NOTES PROVIDE AND INSTALL NEW DISCONNECT SWITCH TO FEED COOLING TOWER PAN HEATERS. USE G.E. #TH3361 R OR APPROVED EQUIVALENT. USE EXISTING CIRCUIT FROM MCC TO FEED HEATERS. INSTALL NEW CONDUIT AND WIRE AS NEEDED. USE CUTLER HAMMER #DT663URK WITH AUXILIARY CONTACTS #DS200EK2. REROUTE POWER FROM MCC BUCKET CIRCUIT BREAKER TO TRANSFER SWITCH FOR NORMAL POWER TO FAN MOTORS. CONDUIT EXISTS FROM MCC TO COOLING TOWER ROOM. PROVIDE AND INSTALL 1-1/2", 3 #1 /0 FROM NXX 1,3,5 TO N. PENTHOUSE. TRANSFER SWITCH TO PROVIDE STANDBY POWER FOR COOLING TOWER FANS. PANEL NXX IS LOCATED ON GARAGE LEVEL IN THE NORTH SWITCHBOARD ROOM. PROVIDE AND INSTALL (2) NEW 50 HP VFD'S FOR COOLING TOWER FANS. USE ALLEN BRADLEY POWERFLEX 400. PART # 22C —D- 072 —A -103. PROVIDE STARTUP SERVICE FROM APPROVED LOCAL VENDOR FOR VFD's. SEE PE210 FOR CMCS COMMUNICATIONS TO VFD's. PROVIDE AND INSTALL (2) NEW 100A, FUSIBLE DISCONNECT SWITCHES. USE G.E. #TH3561R. ELECTRICAL MASTER COL REFERENCE NOTES: SEE DWG. 11.14N -0E2, 480Y/277V0LT POWER MAIN FEEDERS AND PANELS. CO ) E 277/480 VOLT SYSTEM BUILDING 11 -14N e +. i NBF LAST REVISION SHEET P JOB NO. 00000 113 JAN 16 2008 PE:-• `E`eI .. NTE ISSUE FOR 0014STRUCTION eiim 7106 SYMBOL DWG Na. E11.14N -PE110 f DATE 10/26/06 OF COMP NO.