HomeMy WebLinkAboutPermit M07-225 - WESTFIELD SOUTHCENTER MALL - SELECT COMFORTSELECT COMFORT
436 SOUTHCENTER MALL
M07 -225
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Value of Mechanical: $20,000.00
Type of Fire Protection: SPRINKLERS
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
doc: IMC -10/06
Citif Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
6364200010
436 SOUTHCENTER MALL TUKW
SELECT COMFORT
436 SOUTHCENTER MALL , TUKWILA WA
WEA SOUTHCENTER LLC
11601 WILSHIRE BLVD , LOS ANGELES CA
JAMES MOORE
833 SE MAIN #242 , PORTLAND OR
Contractor:
Name: TIMBERWOLFF CONSTRUCTION INC
Address: 1659 W ARROW RTE , UPLAND CA
Contractor License No: TIMBECIO21DM
MECHANICAL PERMIT
DESCRIPTION OF WORK:
TENANT IMPROVEMENT: INSTALL NEW VARIBLE AIR VOLUME BOX, REQUIRED DUCTING, AND
EXHAUST FAN.
EOUIPMENT TYPE AND OUANTITY
0
0
0
0
0
0
1
0
0
1
0
0
0
0
* *continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 503 577 -8859
Phone: 909 949 -0380
Expiration Date: 03/08/2010
M07 -225
04/14/2008
10/11/2008
Fees Collected: $384.83
International Mechanical Code Edition: 2006
Boiler Compressor:
0 HP /100,000 BTU 0
3-15 HP /500,000 BTU 0
15-30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 9
Thermostat 1
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
M07 -225 Printed: 04 -14 -2008
Permit Center Authorized Signature:
I hereby certify that I have read and = x ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied ' , whether specified herein or not.
The granting of ermit do - s not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc
construction or - ; F? • g' am authorized to sign and obtain this mechanical permit.
Signature:
Print Name:
doc: IMC -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
0
w
POO 1474V64
Permit Number: M07 -225
Issue Date: 04/14/2008
Permit Expires On: 10/11/2008
Date: 6 l DI
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender
or abandoned for a period of 180 days from the last inspection.
M07 -225 Printed: 04 -14 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
436 SOUTHCENTER MALL TUKW
SELECT COMFORT
1: ** *BUILDING DEPARTMENT CONDITIONS * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M07 -225
ISSUED
10/22/2007
04/14/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206 - 431- 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
doc: Cond -10/06
M07 -225 Printed: 04 -14 -2008
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: httn: / /www.ci.tukwila.wa.us
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
20: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this
project.
21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond -10/06
* *continued on next page **
M07 -225 Printed: 04 -14 -2008
Signature:
Print Name: C/11F9L
doc: v
Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 - 3665
Web site: http: / /www.ci.tukwila.wa.us
Date:
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this p = * 't does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the • - •rmance of ' ..
k' f
M07 -225 Printed: 04 -14 -2008
Mailing Address:
CITY OF TUKVVILL)
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.citukwila.wa.us
Site Address: 1.. Suite Number: ri:Za Floor:
Tenant Name:S r...L. c1' COVIrfirlarZT New Tenant: SZ1/4... Yes 0 ..No
Property Owners Name:
Mailing Address:
Name: c3C..vAc..c, 14dre--
Mailing Address. €3 Se WI c..11m. **-2
E-Mail Address: jc.....111A 4 ?tt . C.OvieN.
Company Name:
Contact Person:
E-Mail Address:
Contractor Registration Number:
Company Name: IA
Mailing Address:
Contact Person: "1 : ) . 6 "NeA a LeAtAkte,..k
Company Name:
Mailing Address:
Contact Person:
E-Mail Address:
QAApplications \Forms-Applications On LineO-2006 • Permit Application.doe
Revised: 9-2006
bh
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
King Co Assessor's Tax No.:
Ot4 CtiQur
City
State
Day Telephone: 505. s
City state Zip
Fax Number: 5 • 29 — 1(g 30
ENERAL CONT
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
•
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
Zip
must .p Fepe.- • by Architect of Recor
City State .% Zip
Day Telephone: 6 45 2 ciw-1 I
E-Mail Address: Fax Number: S 944 7
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
Valuation of Project (contractor's bid price): $ `3S Existing Building Valuation: $
Scope of Work (please Tr ' e provide detailed information): wv : iMrovew.ty & Pagj nJ
WCAAS ran Ine?.1Rrp � 1 vv
Will there be new rack storage? ❑.... Yes ANo If yes, a separate permit and plan submittal will be required.
1381
Compact:
❑ No If "yes ", explain:
Handicap:
PLANNING DIVISION:
Single family building footprint (: of the foundation of all structures, plus any decks o - r 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, p ' de the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documen - on that shows that the principal owner lives in one of the dwellings his or her primary residence.
Number of Parking Staff • vided: Standard:
Will there be a chan n use? ❑ Yes
FIRE PROTE ' ON/HAZARDOUS MATERIALS:
prinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Sae Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q:\ApplicationsWPorms- Applications On Linel3 -2006 - Pena Applieation.doc
Revised: 9 -2006
bb
Page 2 of 6
— unit Type: ;
01
`Unit: Type
Qty :
!Unit Type: I'P
6
B oiler /Compressor; ;
Qfiy
Furnace<100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0-3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
4
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
1
Thermostat
t
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
MECHANICAL CONTRACTOR INFORMATION
Company Name: 'MN
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
city
Day Telephone:
Fax Number:
State
Zip
Expiration Date:
Valuation of Mechanical work (contractor's bid price): $ 2
Scope of Work (please provide detailed information): INISIA� ! VCAX1c.W AUK 1)011,1w -
Q I"
Use: Residential: New ....0 Replacement .... 0
Commercial: New ..![ Replacement ....
Fuel Type: Electric ... SJ Gas ....❑ Other:
Indicate type of mechanical work being installed and the quantity below:
QAApplications\Porms- Applications On Line\3 -2006 - Permit Appliation.doc
Revised: 9 -2006
bb
Page 4 of 6
Scope of Work (please provide detailed information):
Call before you Dig: 1- 800-424 -5555
Water District
❑ ...Tukwila 0... Water District #125
❑ ...Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certific
Please Public Works Bulletin #1 for fees and estimate sheet.
❑ .. Highline
❑ ... ValVue ❑ .. Renton
❑... Sewer Availability Provided
❑ ...Renton
❑ ...Seattle
Septic System:
p On -site Septic System — F r on -site septic system, provide 2 copies of a current septic design approved b ' 'rig County Health Department.
Submitted with Application (mar r ones which apply):
❑ ...Civil Plans (Maximum Paper - 22" x 34 ")
❑ ...Technical Information Report (Sto Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agre • nt(s) ❑ ...Hold Harmless — (SAO)
❑ ...Hold Harmless — (ROW)
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 72 • • urs ❑ .. Right -of- - y Use - Profit for less than 72 hours
❑ ...Right -of -way Use - No Disturbance ❑ .. Right - -way Use — Potential Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
❑ ...Total Cut cubic yards
❑ ...Total Fill cubic yards
❑ ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
❑ ...Frontage Improvements
0 ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ ...Permanent Water Meter Size... WO #
❑ ...Temporary Water Meter Size.. WO #
❑ ...Water Only Meter Size WO #
❑ ...Sewer Main Extension lic _ Private
❑ ...Water Main Extension ' ublic _ Private
FINANCE INFORMATION
❑ ...Water
Water Meter Refund/Billing:
Name:
Mailing Address:
Q:\Applicaiions\Forms- Applications On Linel3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
.. Work in Flood Zone
.. Storm Drainage
❑ .. Abandon S ank ❑ .. Grease Interceptor
❑ .. Curb Cut ❑ .. Channelization
❑ .. Pavem t Cut ❑ .. Trench Excavation
❑ .. Loo • d Fire Line ❑ .. Utility Undergrounding
Fire Line Size at Property a Number of Public Fire Hydrant(s)
❑ ...Sewer ❑ ...Sewage Treatment
educt Water Meter Size
Monthly Service Billing to:
Name:
Mailing Address:
Day Telephone:
City
State Zip
Day Telephone:
City
State Zip
Page 3 of.6
PERMIT A.PPLCATT..,t,T ;,t.,.�T . Applicable all - - .
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO A PPLY FOR THIS PERMIT.
BUILDING OWNE OI ALT 11 i • RIZED AGENT:
Signature: C
Print Name: J W� 2SS Macrr-e-
Mailing Address: 3 3 sm. 'r' f.0,— 24'L
Q:'Appliations \Fonm- Applications On Line\3 -2006 • Permit Appliation.doc
Revised: 9 -2006
bh
Day Telephone:
City
Date: 1 0 - 2 2. 6 7
s 617 • E9s51
6rL
01-721 - 5
State Zip
Date Application Accepted:
�n�221v�-
Date Application Expires: O l
Staff Initials: • / '
Page 6 of 6
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: �,JD
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
:F.
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Building sewer or trailer
park sewer
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Valuation of Plumbing •rk (contractor's bid price): $ 3 100CD
Valuation of Gas Piping wo contractor's bid price): $
Scope of Work (please provide • ailed information):
Vp S1 *- era r - brLf),\r�
Indicate type of plumbing fixtures and/or gas piping outlets be
ure
Drinking fountain or water
cooler (per head)
Food -waste grinder,
commercial
Floor drain
Shower, single he
Lavatory
Rain water
drain (insi
Repair or • t teration of water
piping : d/or water treating
equip ent
Q:\Appiiations\Ponro- Appliations On Lineu -2006 - Permit Application.doc
Revised: 9 -2006
bb
sy em — per
uilding)
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sinks
Urinals
Sewer:
1P('
l
h fountain
R • • r, indirect
waste
Water Closet
Water heater and/o
vent
Repair or alteration
of drainage or vent
piping
City
Day Telephone:
Fax Number:
Expiration Date:
tailed and the quantity below:
' Qty
State
Gas piping outlets
Additional medical gas
inlets/outlets — six or more
Medical gas piping system
serving one to five
inlets/outlets for specific gas
Zip
Page 5 of 6
RECEIPT NO: R08 -01164
Initials: JEM
User ID: 1165
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http.i /www. ci. tukwila. wa. us
Payee: TIMBERWOLFF CONSTRUCTION, INC.
SET ID: 1211C SET NAME: SELECT COMFORT
SET TRANSACTIONS:
Set Member Amount
D07 -396 614.68
EL07 -598 541.20
M07 -225 313.86
PG07 -285 128.00
TOTAL: 1,597.74
TRANSACTION LIST:
Type Method
Payment
ACCOUNT ITEM LIST:
Description
Check 2208
BUILDING - NONRES
ELECTRICAL PERMIT - NONR
MECHANICAL - NONRES
PLUMBING - NONRES
STATE BUILDING SURCHARGE
Description
SET RECEIPT
TOTAL:
Account Code
000/322.100
000.322.101.00.0
000/322.100
000/322.100
000/386.904
TOTAL:
Payment Date: 04/14/2008
Total Payment: 1,597.74
Amount
1,597.74
1,597.74
Current Pmts
610.18
541.20
313.86
128.00
4.50
1,597.74
RECEIPT NO: R07 -02299
Initials: JEM
User ID: 1166
Payee: PRECISION PERMIT SERVICE
SET ID: S000000878 SET NAME: Trap set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
r
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www.ci.tukwila.wa.us
D07 -396 396.62
EL07 -598 135.30
M07 -225 70.97
PG07 -285 32.00
TOTAL: 634.89
SET RECEIPT
Payment Date: 10/22/2007
Total Payment: 634.89
TRANSACTION LIST:
Type Method Description Amount
Payment Check 5055 634.89
TOTAL: 634.89
ACCOUNT ITEM LIST:
Description
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
Account Code Current Pmts
000.345.832.00.0 135.30
000/345.830 499.59
TOTAL: 634.89
Project; �p
` e.
Type of Inspection*
1 1v A
k
I« ( e -
Address: ` i (v Y I A c t
Date Called:
Special Instructions:
Date Wanted:
_ l -- - e)
Requester:
Phone No:
C l Ut —&52 -2 s
I
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION rr"
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
COMMENTS:
, K Qi ra Vly) /c._ r
Approved per applicable codes. El Corrections required prior to approval.
tEINSPECTION FEE REQUIRED. Prior to inspection, fee must be
t 6k00 Southcenter Blvd., Suite 100. Call to schedule reinspection.
(Receipt No.:
'Date:
project: 5e test 6004;i+.
TYpiI Ok,Qion: 1 K 7014W I%
A
Address: 93 /
mAL`
Date Called:
Special Instructions:
Date Wanted:
7/ iqJ., a.m.
p.m.
Requester:
Phone No: 1 4 p 6 5 2:
rz
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION (-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
COMMENTS:
VOW Pow r ■ AddreSS' rya . - rots
A,r4v 4 t—A C
(Inspector:
+Approved per applicable codes.
Corrections required prior to approval.
'Date: w, Y/ or
El $60.00 REINSPgCTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
'Date:
Pro t: ,� j
(�'
Type Inspection: .,
v
Addle: 111
1 f
Date Called:
Special Instructions:
Date Wanted:
C�
_
5 q°
p. .
Requester:
147 eAo:
3
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1\
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3f 7
al Approved per applicable codes. El Corrections required prior to approval.
COMMENTS: e k--
'Inspector Date: t
El $60.00 NSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reirtspection.
'Receipt No.:
'Date:
i
Pro ect: l
leer Go Y1 For f'
Type of Inspection:
Raifti I`
Address:
1 1)6 >7i i1
Date Called:
Special Instructions:
Date Wanted:
,,y Li 2 ( /
of j j
Requester:
Phone No:
19 1
6 1a ,2
1 /
007 -a3s
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION It-
6300 Southcenter Blvd., #100, Tukwila, WA, 98188 (206)431 -3670
ID Approved per applicable codes.
IZI Corrections required prior to approval.
El $60.df1'ftEINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
'Date:
COMMENTS:
41 /2 1 Se i � S4'f, c �/`ac c ivl
vA V.
Co nit 1 iA u.c.} c o v1 e c. #-i ovt S
�// -1/
Inspector:
'
Pr o'e r �.T� o
oe of 1 ection:
Ad�lr o . , , , D
Date Called:
Special Instructions: D
Date Wanted:
INSPECTION NO.
INSPECTION RECORD 22--
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION IC"
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
ID Approved per applicable codes. El Corrections required prior to approval.
COMMENTS: /,
, i n5cd cLAQ_
Date / /OA e
J $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be
pai at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
'Date:
Project: se { G 4 c 14 _ coteji
Type of Ins ion:
S P cwo, L TA
Eet r,-s5
fvt-e....k_
Address: U 3 G C c .
Suite #:
Contact Pers n:
Permits:
Occupancy Type:
Spedal Instructions:
I
Phone No.:
Needs Shift Inspecction:
Sprinklers:
Are Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
INSPECTION NUMBER
roved per applicable codes.
• Word/Iron Record Form.Doc
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
1/13/06
5- /65
P'107 -
OP - fi- Os'
pe - 31,E
PERMIT NUMBERS
Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Corrections required prior to approval.
COMMENTS:
5 P jv -- Ok
0
Ave 4. — ,_
ILspect°° f 5 1'
Date:. 7 // to /
H
tt. . n $80.00 REINSPECTION FEE REQUIRED. You will receive _an invoice from
�� !! the City of Tukwila Finance Department. Call to schedule a reinspection.
T.F.D. Form F.P. 113
03 -05 -2008
JAMES MOORE
833 SE MAIN #242
PORTLAND OR 97213
RE: Permit Application No. M07 -225
436 SOUTHCENTER MALL TUKW
Dear Permit Applicant:
In reviewing our current permit application files, it appears that your permit application applied for on 10/22/2007 , has not been
issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical
Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and
void. Your permit application expires on 04/19/2008 .
If you choose to pursue your project, a written request for extension of your application addressed to the Building Official,
demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/19/2008. If it is
determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date.
In the event we do not receive your written request for extension, your permit application will become null and void and your project
will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
, II
xc:
er Marshall
t Technician
Permit File No. M07 -225
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665
DEPARTMENTS:
Comments:
Documents/routing slip.doc
2 -28 -02
7I
ision
?ERMIT GOURD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M07 -225 DATE: 10 -22 -07
PROJECT NAME: SELECT COMFORT
SITE ADDRESS: SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Revision # After Permit Issued
Response to Correction Letter #
TUES/THURS ROUT G:
Please Route Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
61i 44_ witil
Fire Prevention
Planning Division
Public Works ❑ Structural ❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete d Incomplete
n
n
DUE DATE: 10-22-07
Not Applicable C
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required
DATE:
DATE:
n
DUE DATE: 11-19-07
Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
TIMBECIO21DM
Licensee Name
TIMBERWOLFF CONSTRUCTION INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601859639
Ind. Ins. Account Id
SECRETARY
Business Type
CORPORATION
Address 1
1659 W ARROW RTE
Address 2
City
UPLAND
County
OUT OF STATE
State
CA
Zip
91786
Phone
9099490380
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
3/14/1998
Expiration Date
3/8/2010
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
WOLFF, MICHAEL
EDWARD
PRESIDENT
03/14/1998
WOLFF, MONIQUE M
SECRETARY
03/14/1998
WOLFF, GLADYS
VICE
PRESIDENT
03/14/1998
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond
Company
Bond
Account Effective Expiration
Cancel
Impaired
Bond
Received
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TIMBECIO21DM 04/14/2008
DIFFUSER, GRILLE & REGISTER SCHEDULE
EQUIP.
TAG
SERVICE
MOUNTING TYPE
DESCRIPTION
ACCESSORIES
FINISH
MANUF.
MODEL
NO.
A
SUPPLY
SURFACE
1" SLOT - 3
SLOT
OBD
SEE
NOTE
TITUS
MP -39
B
SUPPLY
LAY -IN
24 "X24"
OBD
ATE
TITUS
TMS
C
RETURN
SURFACE
48 "x6" - 1/4"
BARS -0' DEFLECTION
- --
SEE
NOTE
TITUS
CT -540
D
RETURN
LAY -IN
24 "X24"
-
SEE
NOTE
TITUS
PAR
NOTE: ALL GRILLES, REGISTERS & DIFFUSERS MUST BE PAINTED TO MATCH CEILING TILE COLOR.
VERIFY EXACT COLOR WITH ARCHITECT.
EXHAUST FAN
TAG
MANUFACTURER
MODEL NO.
TYPE
CFM
S.P.
WATTS
VOLTAGE
ACCESSORIES
EF -1
GREENHECK
SP -B110
CEILING
100
.25
80
SEE ELEC
BACKDRAFT DAMPER
NOTE:
TOILET EXHAUST FAN SHALL BE INTERLOCKED WITH TOILET ROOM LIGHT SWITCH.
PROJECT
SELECT COMFORT
SOUTHCENTER MALL
SUITE # 1005
633 SOUTHCENTER
PARKWAY
TUKWILA, WA 98188
PROJECT NO. 408865 -13
L
3.Lva
LO/60/O t
NO1SJA3El
PER L.L. /ARCH
T ON
C
<CCCCC
IF YOU HAVE ANY QUESTIONS REGARDING THE
MECHANICAL PLANS PLEASE CALL THE MECHANICAL
DESIGNER.
DESIGNER: CRAIG ENGLE 612- 465 -7680
OR
SUPERVISOR: GREG STEINMETZ 612- 465 -7684
RE
CITY
OCT
PERK
An'
CEIVED
OF TUKWIL A
2 2 2007
T CENTER
225
U
I✓
w
w
2
cn
0
O
I-
H
DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE.
COOLING
CFM
MIN CFM
HEATING
CFM
MIN CFM
1000 EXT. S.P.
HEATING CAP
FAN HP
VARIABLE AIR VOLUME BOX SCHEDULE
MANUF. & MODEL ENVIRO -TEC 1018 W/ 1/2 HP DRIVE, 5KW COIL,
AND FILTER RACK (VERIFY CONTROL TYPE)
NOTES:
1. UNIT SHALL BE EQUIPPED WITH AUTOMATIC RESET THERMAL CUTOUT,
AIRFLOW SWITCH, DISCONNECT SWITCH, AND CONTACTORS.
2. CONNECT VAV BOX TO MALL ENERGY MANAGEMENT SYSTEM, IF
REQUIRED.
SPACE LOAD CALCULATIONS
PER 2006 IMC SECTION 606
Install smoke detector to shut down air distribution
by VAV's when the total combined C F M of all
VAV's (to include other tenants) sharing the same
plenum space exceeds 2000 CFM.
(See IMC 606.2.2 for approved method of detection)
NEW TOILET EXHAUST FAN EF-1 - CONNECT -- i
6" RIGID DUCT W/ BACKDRAFT DAMPER TO
EXISTING MALL EXHAUST SYSTEM. VERIFY
ROUTING AND LOCATION ON SITE.
NEW THERMOSTAT - MOUNT 4' -0" AFF.
PROVIDE CLEAR - LOCKING COVER.
EXISTING LANDLROD SUPPLY AIR DUCT.
VERIFY ROUTING, SIZE, AND LOCATION
ON SITE.
C r
A
G7 H
A
200
C = =
0
IA
00
TENANT MUST MAINTAIN A 6" MINIMUM CLEAR OPEN HEIGHT
ABOVE COMMON TENANT DEMISING WALLS AND BELOW
STRUCTURE THAT WOULD ALLOW THE PASSAGE OF RETURN
AIR BACK TO THE UNIT.
FLEX. DUCT 5' -O" MAX. LENGTH.
TYPICAL FOR ALL.
0
A
200 .-
NEW TENANT'S CONTRACTOR PROVIDED
VAV -1 W/ 5KW INTEGRATED HEAT -
SEE SCHEDULE FOR BALANCING.
VERIFY LOCATION ON SITE.
CONNECT NEW 10" DIA SUPPLY AIR DUCT
TO EXISTING LANDLORD SUPPLY AIR SYSTEM.
VERIFY ROUTING AND LOCATION ON SITE.
TENANT MUST MAINTAIN A 6" MINIMUM CLEAR OPEN HEIGHT
ABOVE COMMON TENANT DEMISING WALLS AND BELOW
STRUCTURE THAT WOULD ALLOW THE PASSAGE OF RETURN
AIR BACK TO THE UNIT.
0
I
FILE COPY
. Permit Na '
Plan review approvsd its subject to woo end orniesions.
Approval of construction documents dose not authorize
the violation of any aticcted cede or mamas. Receipt
of approved P' Copy) adwvaledged•
City of Tukwila
BUILDING DIVISION
R, 40,9N the sow
act
� � made �
n9e'o s otst p a to��
t wo 01 d`0 p I�a
10 via �� �a1 plat+ cep
and
CUM COMPLIANC5-__
APPRO
1 r .
Ci Ot
MECHANICAL SYMBOLS
X
•A -10 "o
450
SUPPLY DIFFUSER
RETURN GRILLE
VOLUME DAMPER
sn SMOKE DETECTOR
DIFFUSER TYPE /NECK SIZE
CFM REQUIRED
(D THERMOSTAT
POINT OF CONNECTION
MECHANICAL NOTES
1• ALL EQUIPMENT, INSTALLATION AND MATERIALS SHALL COMPLY WITH ALL
APPLICABLE LANDLORD CRITERIA.
• THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO
FINAL BID, ALL EXISTING STUB-INS, TAPS, ETC. FOR PLUMBING AND
MECHANICAL SYSTEMS WITHIN TENANT SPACE.
• NO FIBERGLASS DUCT BOARD ALLOWED.
• BRANCH DUCT RUN OUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER
NECK UNLESS OTHERWISE SPECIFIED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS
TO THE LANDLORD'S BASE SYSTEMS. COORDINATE ALL SYSTEMS IN THE
FIELD.
6. VERIFY LOCATION OF ANY PENETRATION OF ROOF WITH LANDLORD. ALL
ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE BY LANDLORD
APPROVED ROOFING CONTRACTOR AT TENANT CONTRACTOR'S EXPENSE.
7. PVC PIPING IS PROHIBITED.
8. ALL FIRE PROTECTION AND SPRINKLER WORK SHALL BE PERFORMED BY
LANDLORD- APPROVED FIRE PROTECTION CONTRACTOR AT THE TENANT'S
EXPENSE.
CONTRACTOR SHALL SUBMIT CERTIFIED AIR BALANCE REPORT INCLUDING ALL
ASSOCIATED AIR TEMPERATURES AND PRESSURES AS APPLICABLE. SEND TWO
COPIES TO OWNER FOR APPROVAL
— 1
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
EYEIectricai
[YPlumbing
[ ' Gas Piping
City of Tukwila
BUILDING DIVISION
r
UGO
G
N
w
Et
Z
O O e
r
2
O w
I"1-.O
w � �
w • J O >-
LLI t
I-
C/)
w
I—
a
U
0
VJ
0
LL.I
w
J
N .
0
0
$ ▪ r--
��
LO
a
i
D
zo
Z
ID
W
E r;
cr
o- N
w o'
❑ a
w
echanical + electrical consulting engineering
27 AUGUST 2007
Minneapolis. Minnesota 55402-1540
nh
50 South Sixth Street /Suite 1100
DOCUMENT DATE
CHECKED BY
FA
ISSUED FOR
DRAWN BY
PROJECT
SELECT COMFORT
SOUTHCENTER MALL
SUITE # 1005
633 SOUTHCENTER
PARKWAY
TUKWILA, WA 98188
PROJECT NO.
408865-13
I jk8 1
3C1
31aa
L0/60/0 1.
NOISIA3b
PER L.L. /ARCH
P ON
««GC<
WORK INCLUDED: EACH CONTRACTOR SHALL VERIFY LANDLORD
REQUIREMENTS. BID AND INSTALLATION SHALL BE BASED ON SUCH REQUIREMENTS. DRAWINGS
AND SPECIFICATIONS.
MECHANICAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER
TRADES ON THE PROJECT PREVENTING UNNECESSARY CONFLICTS OR DELAYS DURING
CONSTRUCTION.
IF FOR ANY REASON EXISTING EQUIPMENT TO BE RE —USED NEEDS REPLACEMENT PARTS, THIS
COST IS TO BE COVERED UNDER ORIGINAL CONTRACT AMOUNT AND WILL NOT BE ACCEPTED AS
AN EXTRA COST OR EXPENSE.
CONTRACTOR MUST INSPECT ALL EQUIPMENT TO BE RE -USED AT TIME OF BIDDING OR
NEGOTIATING PERIOD.
CONTRACTOR SHALL EXAMINE THE SITE, COMPARE IT WITH DRAWINGS AND SPECIFICATIONS
AND BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO
ALLOWANCE WILL SUBSEQUENTLY BE MADE IN BEHALF OF THIS CONTRACTOR BY REASON OF
ANY ERROR ON HIS PART.
CODES AND STANDARDS: ALL CODES, ORDINANCES, RULES, REGULATIONS, ORDERS, AND
OTHER LEGAL REQUIREMENTS WITH WHICH COMPLIANCE IS REQUIRED BY GOVERNING
AUTHORITIES SHALL BE ADHERED TO.
TENANTS CONTRACTORS SHALL VERIFY WITH HVAC PLAN TO COORDINATE THE REQUIREMENT
OF PLENUM RATED FIXTURES, PIPING, WIRING, ETC. FAILURE TO DO SO COULD RESULT IN
THE REMOVAL AND REPLACEMENT OF THESE ITEMS AT NO ADDITIONAL COST TO THE
TENANT.
SCOPE
A. THE WORK COVERED BY THIS SPECIFICATION INCLUDES THE COMPLETE HEATING AND AIR
CONDITIONING SYSTEM.
B. THE WORK TO BE PERFORMED UNDER THE HEATING AND AIR CONDITIONING
SPECIFICATIONS AND DRAWINGS CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR
THE COMPLETE INSTALLATION OF ALL HEATING AND AIR CONDITIONING SYSTEM FOR
TENANT SPACE.
THE WORK SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, THE FOLLOWING:
1. HEATING /COOLING UNITS
2. TOILET ROOM EXHAUST SYSTEMS .
3. AUTOMATIC, TEMPERATURE CONTROL
4. DUCTWORK AND AIR CONTROL
5. USE OF CRANE TO PLACE ROOF TOP EQUIPMENT (WHEN REQUIRED)
GENERAL:
A. THIS SPECIFICATION IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL,
AND EQUIPMENT NECESSARY TO PROPERLY INSTALL, ALTER, ADJUST, AND PUT IN
OPERATION, THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM.
B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE
WORK INCLUDED IN THIS CONTRACT.
LAWS, ORDINANCES AND REGULATIONS:
A. ALL SYSTEMS IN ALL AND /OR PART SHALL CONFORM TO ALL PERTINENT LAWS,
ORDINANCES AND REGULATIONS OF ALL BODIES HAVING JURISDICTION, AT ALL
GOVERNING LEVELS, NOTWITHSTANDING ANYTHING IN THESE DRAWINGS OR
SPECIFICATIONS TO THE CONTRARY. IN CASE OF CONFLICT BETWEEN GOVERNING LEVELS,
THE MORE STRINGENT LAWS SHALL APPLY.
B. THE CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND
INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH
HIS WORK.
MATERIALS AND EQUIPMENT:
A. ALL MATERIALS SHALL BE NEW AND SHALL BE OF THE TYPE AND SHALL MEET THE
CAPACITIES OF EQUIPMENT SPECIFIED ON THE DRAWINGS. ALL MATERIALS AND
EQUIPMENT UTILIZED SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA.
B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS
REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH
ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE
TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS.
C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED.
WORKMANSHIP:
A. ALL HEATING EQUIPMENT SHALL BE INSTALLED IN A WORKMANLIKE MANNER MEETING THE
ACCEPTED STANDARDS OF THE HEATING INDUSTRY. THE WORK SHALL BE DONE BY SKILLED
HEATING CRAFTSMAN, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION
OF ASHRAE AND /OR THE SMACNA MANUAL.
CUTTING, PATCHING AND PAINTING:
UNLESS OTHERWISE DIRECTED BY THE LANDLORD CRITERIA, THE CONTRACTOR SHALL PERFORM
ALL CUTTING AND PATCHING REQUIRED IN CONNECTION WITH HIS WORK. ALL FINISHED
SURFACES THAT ARE CUT SHALL BE REPLACED IN KIND SO THAT THERE ARE NO VISIBLE
EVIDENCE OF "PATCH ".
PAINTING OF MECHANICAL WORK SHALL BE BY PRIME CONTRACTOR. ALL EQUIPMENT WHICH
HAS HAD THE FINISH DAMAGED BY INSTALLATION OR TRANSPORTATION SHALL BE
REFINISHED.
ROOF AND OTHER PENETRATIONS:
EACH CONTRACTOR REQUIRING OPENINGS IN THE ROOF OF THE BUILDING STRUCTURE (WHERE
REQUIRED) SHALL MAKE ARRANGEMENTS WITH THE LANDLORD FOR SUCH OPENINGS. PROCEDURE
AND COST ARRANGEMENTS SHALL BE OUTLINED IN THE LANDLORD CRITERIA. COMPLY WITH
ALL LANDLORD REQUIREMENTS. ALL ROOF PENETRATIONS SHALL BE ARRANGED TO PROVIDE A
WEATHER —TIGHT INSTALLATION. THE INSTALLATION SHALL INCLUDE, WHERE REQUIRED,
VENTILATING COLLARS TO GIVE PROPER CLEARANCE FROM COMBUSTIBLE ROOFS, FLOORS,
CEILINGS OR OTHER SUCH STRUCTURES. FIRE -- PROOFING SHALL BE PROVIDED USING
MATERIALS CONFORMING WITH MUNICIPAL CODES AND ORDINANCES.
MECHANICAL UNIT:
MECHANICAL FIRE PROTECTION
DUCTWORK:
A. ALL DUCTWORK SHALL BE INSTALLED AS SHOWN ON MECHANICAL DRAWINGS.
B. THE DUCTWORK SHALL BE CLEAR INSIDE OF THE SIZES SHOWN ON
THE DRAWINGS. ALL DUCTS TO BE SHEET METAL DUCTS AS PER
ASHRAE AND SMACNA GUIDLINES.
C. FLEXIBLE DUCTS SHALL BE LIMITED TO 5'—O" MAX. FOR CONNECTION TO AIR DEVICES.
D. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 GALVANIZED SHEET METAL WITH IRON
SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5' —O" ON CENTER. DUCTWORK
MATERIALS SHALL BE PER CURRENT MECHANICAL CODE.
DUCTWORK INSULATION:
SUPPLY FROM THE AIR CONDITIONING UNIT SHALL BE WRAPPED WITH 1 -1/2" THICK 1 LB /CUFT
FIBERGLASS, FOIL BACKED INSULATION TO PREVENT CONDENSATION.
GRILLES AND DIFFUSERS:
GRILLES AND DIFFUSERS SHALL BE AS MANUFACTURED BY KREUGER, HART AND COOLEY,
BARBERCOLMAN, OR TITUS. EACH IS TO BE HUED WITH A VOLUME DAMPER. (OPPOSED
BLADE DAMPER)
TESTING AND BALANCING CERTIFIED (AABC OR NABB)
INDEPENDENT TESTING COMPANY TO TEST AND BALANCE SYSTEM TO CFM AS SPECIFIED.
REPORT RESULTS TO TENANT AND ARCHITECT.
GUARANTEE:
A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS,
EQUIPMENT, AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE
OF OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT
INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD.
B. THE GUARANTEE SHALL INCLUDE RESTORATION OF ITS ORIGINAL CONDITION OF ALL
ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE.
C. ALL SUCH REPAIRS AND /OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE
CONVENIENCE OF THE OWNER.
SUBSTITUTIONS:
A. APPROVALS OF SUBSTITUTIONS FOR "APPROVED EQUAL ", MUST BE IN WRITING AND
SUBSTITUTION MUST BE APPROVED BEFORE INSTALLATION. INSTALLATION WITHOUT PRIOR
APPROVAL MAY RESULT IN CONTRACTOR REMOVING SUBSTITUTION AND REPLACING IT WITH
SPECIFIED ITEM AT HIS EXPENSE.
B. APPROVAL MAY BE GIVEN BY ARCHITECT, ENGINEER OR OWNER.
TEMPERATURE CONTROL:
FURNISH AND INSTALL NEW COMPATIABLE THERMOSTAT AS LISTED BELOW.
A. TEMPERATURE CONTROL SHALL BE BY A WALL MOUNTED HEATING /COOLING THERMOSTAT,
WITH SUBBASE HAVING SELECTOR SWITCHES FOR "ON /AUTO" AND "HEAT /OFF /COOL"
TEMPERATURE RANGE FROM 50 DEGREES F. TO 90 DEGREES F.
B. THIS STANDARD SYSTEM TO BE USED UNLESS SPECIAL CONTROL SYSTEM IS CALLED FOR
OR SHOWN ON DRAWINGS.
A.
B.
NEW ENVIRO—TEC 1018 W/ 1/2 HP MOTOR AND 5KW HEATING COIL, SEE SCHEDULE.
VAV TERMINAL UNIT SEQUENCE OF OPERATION:
COOLING CYCLE
AT THE DESIGN COOLING CONDITION, THE PRIMARY AIR VALVE IS HANDLING THE
MAXIMUM SCHEDULED PRIMARY AIRFLOW CAPACITY WHILE THE UNIT FAN IS OFF. AS
THE COOLING LOAD DECREASES, THE PRIMARY AIR VALVE THROTTLES TOWARD THE
MINIMUM SCHEDULED PRIMARY AIRFLOW CAPACITY.
HEATING CYCLE
UPON A DROP IN SPACE TEMPERATURE BELOW THE SETTING OF THE THERMOSTAT,
THE PRIMARY AIR VALVE SHALL THROTTLE TO THE MINIMUM PRIMARY AIRFLOW
CAPACITY WHILE THE UNIT FAN IS ON. IF THE DAMPER REACHES THE MINIMUM SET
POINT THE DUCT HEATER SHALL TURN ON UNTIL THE CALL FOR HEAT IS SATISFIED.
A
EXECUTION — INSTALLATION:
LANDLORD NOTES
LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING
STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS
DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST PREQUIREMENTS
OF NFPA 13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED.
TENANT SHALL CONNECT A FIRE SPRINLER SYSTEM TO LANDLORD'S SPRINKLER
SYSTEM WITHIN THE DEMISED PREMISSES USING APPROVED MECHANICAL FITTINGS.
TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS
REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE.
TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE
REQUIREMENTS OF TE STATE OF WASHINGTON, CITY OF OF TUKWILA FIRE
DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD
PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL
TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING
DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZING SHALL BE
HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE
LATEST REQUIREMENTS OF NFPA 13.
ALL SPRINKLER HEADS SHALL BE CONCEALED WITH COVER PLATES IN PUBLIC
AREAS.
ADD RECESSED SPRINKLER HEAD IN REAR ALCOVE CEILING.
A. GENERAL CONTRACTOR TO VERIFY MALL SPRINKLER CONTRACTOR REQUIREMENTS AND USE
SPECIFIED CONTRACTOR IF REQUIRED.
B. INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 13. INSTALL SPRINKLER
PIPING PRODUCTS WHERE REQUIRED IN ACCORDANCE WITH RECOGNIZED PRACTICES TO
ENSURE THAT FIRE PROTECTION SPRINKLER PIPING COMPLIES WITH GOVERNING
REQUIREMENTS AND SERVES THE INTENDED PURPOSES.
C. EXAMINE OTHER WORK SHOWN ON THE DRAWINGS . AND CONDITIONS AT THE JOB SITE.
COORDINATE THE ROUTING OF WORK WITH OTHER TRADES TO AVOID INTERFERENCE WITH
OTHER INSTALLATIONS.
D. PIPE ROUTING AND SPRINKLER HEAD LOCATIONS SHALL BE LOCATED AS REQUIRED TO
AVOID EQUIPMENT, PLUMBING, HEATING AND AIR CONDITIONING PIPING, DUCTWORK,
LIGHTING FIXTURES, ELECTRICAL CONDUITS AND BUS DUCTS AND SIMILAR WORK.
E. PROVIDE PIPE OFFSETS AS REQUIRED TO COMPLETE THE INSTALLATION. MODIFY PIPE,
PREFABRICATED PIPING, PIPE HANGERS AND OTHER COMPONENTS AS REQUIRED TO FIT
THE JOB SITE CONDITIONS.
CLEANING AND FLUSHING: PRIOR TO CONNECTING SPRINKLER PIPING FOR FLUSHING,
FLUSH WATER FEED MAINS, LEAD —IN CONNECTIONS AND CONTROL PORTIONS OF SPRINKLER
PIPING. AFTER FIRE SPRINKLER PIPING INSTALLATION HAS BEEN COMPLETED AND
BEFORE PIPING IS PLACED IN SERVICE, FLUSH ENTIRE SPRINKLER SYSTEM UNDER
PRESSURE, AS REQUIRED TO REMOVE FOREIGN SUBSTANCES AS REQUIRED BY NFPA 13.
CONTINUE FLUSHING UNTIL WATER IS CLEAR AND CHECK TO ENSURE THAT DEBRIS HAS
NOT CLOGGED SPRINKLERS.
TESTING:
A. AFTER FLUSHING SYSTEM, TEST FIRE SPRINKLER PIPING HYDROSTATIC ALLY IN
ACCORDANCE WITH NFPA 13, AT NOT LESS THAN 200 PSI OR AT 50 PSIG. CHECK SYSTEM
FOR LEAKAGE AT JOINTS. MEASURE HYDROSTATIC PRESSURE AT LOW POINT OF EACH
SYSTEM OR ZONE BEING TESTED.
B. REPAIR OR REPLACE PIPING SYSTEM AS REQUIRED TO ELIMINATE LEAKAGE IN
ACCORDANCE WITH NEPA STANDARDS FOR "LITTLE OR NO LEAKAGE" AND RETEST AS
SPECIFIED TO DEMONSTRATE COMPLIANCE.
SPRINKLER MAINS AND BRANCHES
A. PIPING MATERIAL: BLACK STEEL, SCHEDULE 40 OR LIGHTWEIGHT SPRINKLER PIPE,
SCHEDULE 10 ASTM A 135 (IF ALLOWED BY LANDLORD AND LOCAL AUTHORITIES).
B. FITTINGS: THREADED, CLASS 175. MECHANICAL COUPLINGS AND TEES OF A ROLLED
GROOVED TYPE WILL BE ACCEPTED (IN LIEU OF THREADED) IF BOTH U.L. LISTED AND
FIRE MARSHAL APPROVED.
INSTALLATION:
C. ALL SPRINKLER PIPING SHALL BE CONCEALED UNLESS OTHERWISE INDICATED. ALL
PIPING SHALL BE LOCATED TO AVOID INTERFERENCE WITH ALL OTHER ELEMENTS ABOVE
CEILINGS, ETC.
D. SUPPORT ALL HORIZONTAL PIPING AT NOT GREATER THAN 10 FEET INTERVALS, EXCEPT
PIPES OF SIZE 1-1/2" AND LARGER WHICH SHALL BE SUPPORTED AT NOT GREATER
THAN FIFTEEN FEET INTERVALS, WITH APPROVED SWIVEL SPLIT RING HANGERS WITH ROD
SUPPORTS AND SWAY BRACES AT EVERY THIRD HANGER.
E. ALL SPRINKLER PIPING SHALL BE INSTALLED SO THAT IS CAN BE THOROUGHLY DRAINED
AND WHERE PRACTICAL, ARRANGE TO DRAIN THE MAIN VALVE.
SPRINKLER HEADS
A. SPRINKLER HEADS IN AREAS WITH LAY —IN AND DRYWALL CEILINGS SHALL BE RECESSED
TYPE , 165 DEGREE RATED, CHROME PLATED HEAD WITH ESCUTCHEON COLOR TO
MATCH CEILING COLOR, VERIFY EXACT COLOR WITH ARCHITECT.
B. SPRINKLER HEADS IN AREA OF NO CEILING SHALL BE CHROME PLATED UPRIGHT.
C. ALL SPRINKLER HEADS SHALL BE 1/2" ORIFICE, RATED AT 165 DEGREES WITH A
K— FACTOR OF 5.65.
D. ALL SPRINKLER HEADS THAT ARE TO REMAIN AND BE REUSED SHALL BE PROTECTED
DURING CONSTRUCTION AND CLEANED THOROUGHLY TO INSURE THAT THEY ARE CLEAR
OF PAINT AND DEBRIS AND ARE IN GOOD WORKING CONDITION, PRIOR TO PROJECT
CLOSEOUT.
E. ALL SPRINKLER HEADS SHALL BE INSTALLED IN ACCORDANCE TO NFPA 13 AND ALL
LOCAL CODES AND AUTHORITIES HAVING JURISDICTION.
A
PLUMBING
SCOPE:
A. THE WORK TO BE PERFORMED UNDER THE PLUMBING SPECIFICATIONS AND DRAWINGS
CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION
OF ALL PLUMBING SYSTEMS FOR TENANT SPACE. THE WORK SHALL INCLUDE, BUT NOT BE
LIMITED TO, THE FOLLOWING:
1. COLD AND HOT WATER SYSTEMS
2. DRAINAGE AND VENT SYSTEMS
3. INSULATION
GENERAL:
A. THIS SPECIFICATIONS IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL,
AND EQUIPMENT NECESSARY TO PROPERLY INSTALL, ALTER, ADJUST, AND PUT INTO
OPERATION, THE COMPLETE PLUMBING SYSTEM .
B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE
WORK INCLUDED IN THIS CONTRACT.
WORKMANSHIP:
ALL WORK MUST BE DONE IN A WORKMANLIKE MANNER TO THE COMPLETE SATISFACTION OF
THE ENGINEERS AND SHALL BE PERFORMED BY QUALIFIED MECHANICS.
A. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, AND SHALL CONFORM TO THE GRADE,
QUALITY AND STANDARDS SPECIFIED HEREIN. ALL MATERIALS AND EQUIPMENT UTILIZED
SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA.
B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS
REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH
ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE
TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS.
C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED.
LAW, ORDINANCES AND REGULATIONS:
A. ALL MECHANICAL SYSTEMS IN ALL AND /OR PART SHALL CONFORM TO ALL PERTINENT
LAWS, ORDINANCES AND REGULATIONS AND ALL BODIES HAVING JURISDICTION, AT ALL
GOVERNING LEVELS, NOTWITHSTANDING IN THESE PLANS AND SPECIFICATION TO THE
CONTRARY. IN CASE OF CONFLICT BETWEEN GOVERNING LEVELS, THE MORE STRINGENT
LAWS SHALL APPLY.
B. CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND
INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH
HIS WORK.
C. WHERE APPLICABLE, ALL MATERIAL SHALL BEAR THE THE NATIONAL BOARD OF FIRE
UNDERWRITER'S SEAL OF APPROVAL. CERTIFICATES TO THIS EFFECT TO BE FURNISHED
TO ARCHITECT TO BE TO ARCHITECT UPON REQUEST.
ESCUTCHEONS:
A. ALL EXPOSED PIPES, EXCEPT AS OTHERWISE DESCRIBED, PASSING THRU WALLS, FLOORS,
CEILINGS, ETC. IN FINISHED SPACES, SHALL BE PROVIDED WITH SOLID PATTERN HEAVY
CEILING, FLOOR OR WALL ESCUTCHEONS WITH SET SCREW. ESCUTCHEONS AND PLATES
SHALL BE OF STEEL OR MALLEABLE IRON WITH PRIME COAT READY FOR PAINTING.
ESCUTCHEONS WILL NOT BE PROVIDED WHERE SLEEVES INTENTIONALLY EXTEND ABOVE
FINISHED FLOOR.
B. ALL EXPOSED PLUMBING SHORT BRANCH CONNECTIONS TO FIXTURES AND /OR EQUIPMENT
PASSING THROUGH WALL OR FLOORS SHALL BE EQUIPPED WITH PRESS BRASS, CHROMIUM
PLATED, SOLID TYPE ESCUTCHEONS.
GUARANTEE:
A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS,
EQUIPMENT, AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE
BY OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT
INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD.
B. THE GUARANTEE SHALL INCLUDE RESTORATION TO ITS ORIGINAL CONDITION OF ALL
ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE.
C. ALL SUCH REPAIRS AND /OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE
CONVENIENCE OF THE OWNER.
TEMPORARY SERVICES:
A. THE CONTRACTOR, AT HIS OWN EXPENSE AND COST, SHALL INSTALL, OPERATE, PROTECT
AND MAINTAIN THE RESPECTIVE TEMPORARY SERVICES AS REQUIRED BY HIS WORK.
TEST OF PIPING AND SYSTEM:
A. THE SYSTEMS OF PIPING AS INSTALLED BY THIS CONTRACTOR MUST BE TESTED WITH
WATER OR AIR AND PROVEN TIGHT TO THE SATISFACTION OF REPRESENTATIVES OF THE
OWNER. TESTING INSTRUMENTS MUST BE FURNISHED BY THE PLUMBING CONTRACTOR.
B. TEST MUST BE MADE WITH WATER, EXCEPT WHEN THERE IS DANGER FROM FREEZING, THEN
TESTS MAY BE MADE WITH AIR. WOODEN PLUGS ARE NOT TO BE USED IN MAKING TESTS.
STERILIZATION OF DOMESTIC WATER SYSTEM:
A. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE
SATISFACTION OF THE A.W.W.A SPECIFICATIONS C601 -53T_
SOIL WASTE AND VENT PIPING:
A. SOIL WASTE PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE, BELL & SPIGOT
TYPE AS REQUIRED.
B. VENT PIPE SHALL BE SERVICE WEIGHT CAST IRON BELL & SPIGOT TYPE AS REQUIRED
PER LOCAL CODE.
INSULATE —ALL LINES (ABOVE CEILING /IN WALLS INCLUDED):
A. INSULATION ON COLD WATER, HOT WATER, CONDENSATE LINES, ETC., SHALL BE
ARMAFLEX II, OR APPROVED EQUAL, WITH THICKNESS AS REQUIRED. MINIMUM THICKNESS
IS 1/2" INCH.
B. INSULATION ON ROOF DRAINS AND ROOF DRAIN LEADERS SHALL BE FIBERGLASS WITH
MULTI — PURPOSE WRAPPING.
SUBSTITUTIONS:
A. SUBSTITUTIONS WILL BE CONSIDERED FOR "OR EQUAL" BUT MUST BE APPROVED IN
WRITING, BY OWNER, ARCHITECT OR ENGINEER, PRIOR TO INSTALLATION.
B. IF, AFTER PLANS ARE COMPLETED, AUTHORITIES RULE THAT HANDICAPPED RESTROOM IS
REQUIRED, BUT NOT SHOWN, USE AMERICAN STANDARD 'CADET —HI" WATER CLOSETS AND
SET LAVATORY AT PROPER HEIGHT WITH LEVER HANDLES. (VERIFY ALL FINAL EQUIPMENT
SPECS WITH PLUMBING DRAWING).
WATER PIPING:
A. WATER PIPING UNDER FLOOR SHALL BE TYPE "K" SOFT COPPER WITH SILVER SOLDER
JOINTS.
B. WATER PIPING ABOVE FLOOR SHALL BE TYPE "L" HARD D COPPER WITH LEAD FREE
SOLDER JOINTS.
W
U
w
I-
I-
w
W
z
0
c<i
W
F-
1-
\ 0 , 0 e C \
RECEIVED
CITY OF TUKWILA
OCT 22 2001
PERMIT CENTER
IF YOU HAVE ANY QUESTIONS REGARDING THE
MECHANICAL PLANS PLEASE CALL THE MECHANICAL
DESIGNER.
DESIGNER: CRAIG ENGLE 612- 465 --7680
OR
SUPERVISOR: GREG STEINMETZ 612-465-7684
MO7ZZS
F-
U)
W
I—
Q
U
0
CO
v)
0
w_
}
w
J
7
n
0
o'
0
to
in
I- N
0 Cr.
W
Z o
z z
W ,�
- ^
a s
N
zC.
w
x
wLL
SPECIFICATIONS
27 AUGUST 2007
DOCUMENT DATE
CONCEPT BY
CHECKED BY
0 2007 Lam ASSOCIATES, LTD. ALL RIGHTS RESERVED
ISSUED FOR
DRAWN BY