Loading...
HomeMy WebLinkAboutPermit M07-225 - WESTFIELD SOUTHCENTER MALL - SELECT COMFORTSELECT COMFORT 436 SOUTHCENTER MALL M07 -225 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Mechanical: $20,000.00 Type of Fire Protection: SPRINKLERS Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Citif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 436 SOUTHCENTER MALL TUKW SELECT COMFORT 436 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA JAMES MOORE 833 SE MAIN #242 , PORTLAND OR Contractor: Name: TIMBERWOLFF CONSTRUCTION INC Address: 1659 W ARROW RTE , UPLAND CA Contractor License No: TIMBECIO21DM MECHANICAL PERMIT DESCRIPTION OF WORK: TENANT IMPROVEMENT: INSTALL NEW VARIBLE AIR VOLUME BOX, REQUIRED DUCTING, AND EXHAUST FAN. EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 1 0 0 1 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 577 -8859 Phone: 909 949 -0380 Expiration Date: 03/08/2010 M07 -225 04/14/2008 10/11/2008 Fees Collected: $384.83 International Mechanical Code Edition: 2006 Boiler Compressor: 0 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 9 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M07 -225 Printed: 04 -14 -2008 Permit Center Authorized Signature: I hereby certify that I have read and = x ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied ' , whether specified herein or not. The granting of ermit do - s not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or - ; F? • g' am authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 0 w POO 1474V64 Permit Number: M07 -225 Issue Date: 04/14/2008 Permit Expires On: 10/11/2008 Date: 6 l DI Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -225 Printed: 04 -14 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 436 SOUTHCENTER MALL TUKW SELECT COMFORT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -225 ISSUED 10/22/2007 04/14/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors doc: Cond -10/06 M07 -225 Printed: 04 -14 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: httn: / /www.ci.tukwila.wa.us shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -225 Printed: 04 -14 -2008 Signature: Print Name: C/11F9L doc: v Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us Date: I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this p = * 't does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the • - •rmance of ' .. k' f M07 -225 Printed: 04 -14 -2008 Mailing Address: CITY OF TUKVVILL) Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Site Address: 1.. Suite Number: ri:Za Floor: Tenant Name:S r...L. c1' COVIrfirlarZT New Tenant: SZ1/4... Yes 0 ..No Property Owners Name: Mailing Address: Name: c3C..vAc..c, 14dre-- Mailing Address. €3 Se WI c..11m. **-2 E-Mail Address: jc.....111A 4 ?tt . C.OvieN. Company Name: Contact Person: E-Mail Address: Contractor Registration Number: Company Name: IA Mailing Address: Contact Person: "1 : ) . 6 "NeA a LeAtAkte,..k Company Name: Mailing Address: Contact Person: E-Mail Address: QAApplications \Forms-Applications On LineO-2006 • Permit Application.doe Revised: 9-2006 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: Ot4 CtiQur City State Day Telephone: 505. s City state Zip Fax Number: 5 • 29 — 1(g 30 ENERAL CONT (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) • City Day Telephone: Fax Number: Expiration Date: State Zip Zip must .p Fepe.- • by Architect of Recor City State .% Zip Day Telephone: 6 45 2 ciw-1 I E-Mail Address: Fax Number: S 944 7 City Day Telephone: Fax Number: State Zip Page 1 of 6 Valuation of Project (contractor's bid price): $ `3S Existing Building Valuation: $ Scope of Work (please Tr ' e provide detailed information): wv : iMrovew.ty & Pagj nJ WCAAS ran Ine?.1Rrp � 1 vv Will there be new rack storage? ❑.... Yes ANo If yes, a separate permit and plan submittal will be required. 1381 Compact: ❑ No If "yes ", explain: Handicap: PLANNING DIVISION: Single family building footprint (: of the foundation of all structures, plus any decks o - r 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, p ' de the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documen - on that shows that the principal owner lives in one of the dwellings his or her primary residence. Number of Parking Staff • vided: Standard: Will there be a chan n use? ❑ Yes FIRE PROTE ' ON/HAZARDOUS MATERIALS: prinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Sae Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\ApplicationsWPorms- Applications On Linel3 -2006 - Pena Applieation.doc Revised: 9 -2006 bb Page 2 of 6 — unit Type: ; 01 `Unit: Type Qty : !Unit Type: I'P 6 B oiler /Compressor; ; Qfiy Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 4 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 1 Thermostat t 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL CONTRACTOR INFORMATION Company Name: 'MN Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: city Day Telephone: Fax Number: State Zip Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 2 Scope of Work (please provide detailed information): INISIA� ! VCAX1c.W AUK 1)011,1w - Q I" Use: Residential: New ....0 Replacement .... 0 Commercial: New ..![ Replacement .... Fuel Type: Electric ... SJ Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: QAApplications\Porms- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9 -2006 bb Page 4 of 6 Scope of Work (please provide detailed information): Call before you Dig: 1- 800-424 -5555 Water District ❑ ...Tukwila 0... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certific Please Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Highline ❑ ... ValVue ❑ .. Renton ❑... Sewer Availability Provided ❑ ...Renton ❑ ...Seattle Septic System: p On -site Septic System — F r on -site septic system, provide 2 copies of a current septic design approved b ' 'rig County Health Department. Submitted with Application (mar r ones which apply): ❑ ...Civil Plans (Maximum Paper - 22" x 34 ") ❑ ...Technical Information Report (Sto Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agre • nt(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 • • urs ❑ .. Right -of- - y Use - Profit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ .. Right - -way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements 0 ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension lic _ Private ❑ ...Water Main Extension ' ublic _ Private FINANCE INFORMATION ❑ ...Water Water Meter Refund/Billing: Name: Mailing Address: Q:\Applicaiions\Forms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh .. Work in Flood Zone .. Storm Drainage ❑ .. Abandon S ank ❑ .. Grease Interceptor ❑ .. Curb Cut ❑ .. Channelization ❑ .. Pavem t Cut ❑ .. Trench Excavation ❑ .. Loo • d Fire Line ❑ .. Utility Undergrounding Fire Line Size at Property a Number of Public Fire Hydrant(s) ❑ ...Sewer ❑ ...Sewage Treatment educt Water Meter Size Monthly Service Billing to: Name: Mailing Address: Day Telephone: City State Zip Day Telephone: City State Zip Page 3 of.6 PERMIT A.PPLCATT..,t,T ;,t.,.�T . Applicable all - - . Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO A PPLY FOR THIS PERMIT. BUILDING OWNE OI ALT 11 i • RIZED AGENT: Signature: C Print Name: J W� 2SS Macrr-e- Mailing Address: 3 3 sm. 'r' f.0,— 24'L Q:'Appliations \Fonm- Applications On Line\3 -2006 • Permit Appliation.doc Revised: 9 -2006 bh Day Telephone: City Date: 1 0 - 2 2. 6 7 s 617 • E9s51 6rL 01-721 - 5 State Zip Date Application Accepted: �n�221v�- Date Application Expires: O l Staff Initials: • / ' Page 6 of 6 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: �,JD Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: :F. Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Building sewer or trailer park sewer Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Valuation of Plumbing •rk (contractor's bid price): $ 3 100CD Valuation of Gas Piping wo contractor's bid price): $ Scope of Work (please provide • ailed information): Vp S1 *- era r - brLf),\r� Indicate type of plumbing fixtures and/or gas piping outlets be ure Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single he Lavatory Rain water drain (insi Repair or • t teration of water piping : d/or water treating equip ent Q:\Appiiations\Ponro- Appliations On Lineu -2006 - Permit Application.doc Revised: 9 -2006 bb sy em — per uilding) Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sinks Urinals Sewer: 1P(' l h fountain R • • r, indirect waste Water Closet Water heater and/o vent Repair or alteration of drainage or vent piping City Day Telephone: Fax Number: Expiration Date: tailed and the quantity below: ' Qty State Gas piping outlets Additional medical gas inlets/outlets — six or more Medical gas piping system serving one to five inlets/outlets for specific gas Zip Page 5 of 6 RECEIPT NO: R08 -01164 Initials: JEM User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http.i /www. ci. tukwila. wa. us Payee: TIMBERWOLFF CONSTRUCTION, INC. SET ID: 1211C SET NAME: SELECT COMFORT SET TRANSACTIONS: Set Member Amount D07 -396 614.68 EL07 -598 541.20 M07 -225 313.86 PG07 -285 128.00 TOTAL: 1,597.74 TRANSACTION LIST: Type Method Payment ACCOUNT ITEM LIST: Description Check 2208 BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE Description SET RECEIPT TOTAL: Account Code 000/322.100 000.322.101.00.0 000/322.100 000/322.100 000/386.904 TOTAL: Payment Date: 04/14/2008 Total Payment: 1,597.74 Amount 1,597.74 1,597.74 Current Pmts 610.18 541.20 313.86 128.00 4.50 1,597.74 RECEIPT NO: R07 -02299 Initials: JEM User ID: 1166 Payee: PRECISION PERMIT SERVICE SET ID: S000000878 SET NAME: Trap set/Initialized Activities SET TRANSACTIONS: Set Member Amount r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us D07 -396 396.62 EL07 -598 135.30 M07 -225 70.97 PG07 -285 32.00 TOTAL: 634.89 SET RECEIPT Payment Date: 10/22/2007 Total Payment: 634.89 TRANSACTION LIST: Type Method Description Amount Payment Check 5055 634.89 TOTAL: 634.89 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES Account Code Current Pmts 000.345.832.00.0 135.30 000/345.830 499.59 TOTAL: 634.89 Project; �p ` e. Type of Inspection* 1 1v A k I« ( e - Address: ` i (v Y I A c t Date Called: Special Instructions: Date Wanted: _ l -- - e) Requester: Phone No: C l Ut —&52 -2 s I INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION rr" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: , K Qi ra Vly) /c._ r Approved per applicable codes. El Corrections required prior to approval. tEINSPECTION FEE REQUIRED. Prior to inspection, fee must be t 6k00 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: project: 5e test 6004;i+. TYpiI Ok,Qion: 1 K 7014W I% A Address: 93 / mAL` Date Called: Special Instructions: Date Wanted: 7/ iqJ., a.m. p.m. Requester: Phone No: 1 4 p 6 5 2: rz INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: VOW Pow r ■ AddreSS' rya . - rots A,r4v 4 t—A C (Inspector: +Approved per applicable codes. Corrections required prior to approval. 'Date: w, Y/ or El $60.00 REINSPgCTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Pro t: ,� j (�' Type Inspection: ., v Addle: 111 1 f Date Called: Special Instructions: Date Wanted: C� _ 5 q° p. . Requester: 147 eAo: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1\ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3f 7 al Approved per applicable codes. El Corrections required prior to approval. COMMENTS: e k-- 'Inspector Date: t El $60.00 NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reirtspection. 'Receipt No.: 'Date: i Pro ect: l leer Go Y1 For f' Type of Inspection: Raifti I` Address: 1 1)6 >7i i1 Date Called: Special Instructions: Date Wanted: ,,y Li 2 ( / of j j Requester: Phone No: 19 1 6 1a ,2 1 / 007 -a3s INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION It- 6300 Southcenter Blvd., #100, Tukwila, WA, 98188 (206)431 -3670 ID Approved per applicable codes. IZI Corrections required prior to approval. El $60.df1'ftEINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: 41 /2 1 Se i � S4'f, c �/`ac c ivl vA V. Co nit 1 iA u.c.} c o v1 e c. #-i ovt S �// -1/ Inspector: ' Pr o'e r �.T� o oe of 1 ection: Ad�lr o . , , , D Date Called: Special Instructions: D Date Wanted: INSPECTION NO. INSPECTION RECORD 22-- Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IC" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ID Approved per applicable codes. El Corrections required prior to approval. COMMENTS: /, , i n5cd cLAQ_ Date / /OA e J $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: se { G 4 c 14 _ coteji Type of Ins ion: S P cwo, L TA Eet r,-s5 fvt-e....k_ Address: U 3 G C c . Suite #: Contact Pers n: Permits: Occupancy Type: Spedal Instructions: I Phone No.: Needs Shift Inspecction: Sprinklers: Are Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER roved per applicable codes. • Word/Iron Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 1/13/06 5- /65 P'107 - OP - fi- Os' pe - 31,E PERMIT NUMBERS Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. COMMENTS: 5 P jv -- Ok 0 Ave 4. — ,_ ILspect°° f 5 1' Date:. 7 // to / H tt. . n $80.00 REINSPECTION FEE REQUIRED. You will receive _an invoice from �� !! the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 03 -05 -2008 JAMES MOORE 833 SE MAIN #242 PORTLAND OR 97213 RE: Permit Application No. M07 -225 436 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 10/22/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 04/19/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/19/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, , II xc: er Marshall t Technician Permit File No. M07 -225 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: Comments: Documents/routing slip.doc 2 -28 -02 7I ision ?ERMIT GOURD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -225 DATE: 10 -22 -07 PROJECT NAME: SELECT COMFORT SITE ADDRESS: SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Issued Response to Correction Letter # TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: 61i 44_ witil Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete d Incomplete n n DUE DATE: 10-22-07 Not Applicable C Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DATE: n DUE DATE: 11-19-07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License TIMBECIO21DM Licensee Name TIMBERWOLFF CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601859639 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 1659 W ARROW RTE Address 2 City UPLAND County OUT OF STATE State CA Zip 91786 Phone 9099490380 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/14/1998 Expiration Date 3/8/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WOLFF, MICHAEL EDWARD PRESIDENT 03/14/1998 WOLFF, MONIQUE M SECRETARY 03/14/1998 WOLFF, GLADYS VICE PRESIDENT 03/14/1998 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Company Bond Account Effective Expiration Cancel Impaired Bond Received https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TIMBECIO21DM 04/14/2008 DIFFUSER, GRILLE & REGISTER SCHEDULE EQUIP. TAG SERVICE MOUNTING TYPE DESCRIPTION ACCESSORIES FINISH MANUF. MODEL NO. A SUPPLY SURFACE 1" SLOT - 3 SLOT OBD SEE NOTE TITUS MP -39 B SUPPLY LAY -IN 24 "X24" OBD ATE TITUS TMS C RETURN SURFACE 48 "x6" - 1/4" BARS -0' DEFLECTION - -- SEE NOTE TITUS CT -540 D RETURN LAY -IN 24 "X24" - SEE NOTE TITUS PAR NOTE: ALL GRILLES, REGISTERS & DIFFUSERS MUST BE PAINTED TO MATCH CEILING TILE COLOR. VERIFY EXACT COLOR WITH ARCHITECT. EXHAUST FAN TAG MANUFACTURER MODEL NO. TYPE CFM S.P. WATTS VOLTAGE ACCESSORIES EF -1 GREENHECK SP -B110 CEILING 100 .25 80 SEE ELEC BACKDRAFT DAMPER NOTE: TOILET EXHAUST FAN SHALL BE INTERLOCKED WITH TOILET ROOM LIGHT SWITCH. PROJECT SELECT COMFORT SOUTHCENTER MALL SUITE # 1005 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 PROJECT NO. 408865 -13 L 3.Lva LO/60/O t NO1SJA3El PER L.L. /ARCH T ON C <CCCCC IF YOU HAVE ANY QUESTIONS REGARDING THE MECHANICAL PLANS PLEASE CALL THE MECHANICAL DESIGNER. DESIGNER: CRAIG ENGLE 612- 465 -7680 OR SUPERVISOR: GREG STEINMETZ 612- 465 -7684 RE CITY OCT PERK An' CEIVED OF TUKWIL A 2 2 2007 T CENTER 225 U I✓ w w 2 cn 0 O I- H DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE. COOLING CFM MIN CFM HEATING CFM MIN CFM 1000 EXT. S.P. HEATING CAP FAN HP VARIABLE AIR VOLUME BOX SCHEDULE MANUF. & MODEL ENVIRO -TEC 1018 W/ 1/2 HP DRIVE, 5KW COIL, AND FILTER RACK (VERIFY CONTROL TYPE) NOTES: 1. UNIT SHALL BE EQUIPPED WITH AUTOMATIC RESET THERMAL CUTOUT, AIRFLOW SWITCH, DISCONNECT SWITCH, AND CONTACTORS. 2. CONNECT VAV BOX TO MALL ENERGY MANAGEMENT SYSTEM, IF REQUIRED. SPACE LOAD CALCULATIONS PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) NEW TOILET EXHAUST FAN EF-1 - CONNECT -- i 6" RIGID DUCT W/ BACKDRAFT DAMPER TO EXISTING MALL EXHAUST SYSTEM. VERIFY ROUTING AND LOCATION ON SITE. NEW THERMOSTAT - MOUNT 4' -0" AFF. PROVIDE CLEAR - LOCKING COVER. EXISTING LANDLROD SUPPLY AIR DUCT. VERIFY ROUTING, SIZE, AND LOCATION ON SITE. C r A G7 H A 200 C = = 0 IA 00 TENANT MUST MAINTAIN A 6" MINIMUM CLEAR OPEN HEIGHT ABOVE COMMON TENANT DEMISING WALLS AND BELOW STRUCTURE THAT WOULD ALLOW THE PASSAGE OF RETURN AIR BACK TO THE UNIT. FLEX. DUCT 5' -O" MAX. LENGTH. TYPICAL FOR ALL. 0 A 200 .- NEW TENANT'S CONTRACTOR PROVIDED VAV -1 W/ 5KW INTEGRATED HEAT - SEE SCHEDULE FOR BALANCING. VERIFY LOCATION ON SITE. CONNECT NEW 10" DIA SUPPLY AIR DUCT TO EXISTING LANDLORD SUPPLY AIR SYSTEM. VERIFY ROUTING AND LOCATION ON SITE. TENANT MUST MAINTAIN A 6" MINIMUM CLEAR OPEN HEIGHT ABOVE COMMON TENANT DEMISING WALLS AND BELOW STRUCTURE THAT WOULD ALLOW THE PASSAGE OF RETURN AIR BACK TO THE UNIT. 0 I FILE COPY . Permit Na ' Plan review approvsd its subject to woo end orniesions. Approval of construction documents dose not authorize the violation of any aticcted cede or mamas. Receipt of approved P' Copy) adwvaledged• City of Tukwila BUILDING DIVISION R, 40,9N the sow act � � made � n9e'o s otst p a to�� t wo 01 d`0 p I�a 10 via �� �a1 plat+ cep and CUM COMPLIANC5-__ APPRO 1 r . Ci Ot MECHANICAL SYMBOLS X •A -10 "o 450 SUPPLY DIFFUSER RETURN GRILLE VOLUME DAMPER sn SMOKE DETECTOR DIFFUSER TYPE /NECK SIZE CFM REQUIRED (D THERMOSTAT POINT OF CONNECTION MECHANICAL NOTES 1• ALL EQUIPMENT, INSTALLATION AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA. • THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO FINAL BID, ALL EXISTING STUB-INS, TAPS, ETC. FOR PLUMBING AND MECHANICAL SYSTEMS WITHIN TENANT SPACE. • NO FIBERGLASS DUCT BOARD ALLOWED. • BRANCH DUCT RUN OUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS OTHERWISE SPECIFIED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE LANDLORD'S BASE SYSTEMS. COORDINATE ALL SYSTEMS IN THE FIELD. 6. VERIFY LOCATION OF ANY PENETRATION OF ROOF WITH LANDLORD. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE BY LANDLORD APPROVED ROOFING CONTRACTOR AT TENANT CONTRACTOR'S EXPENSE. 7. PVC PIPING IS PROHIBITED. 8. ALL FIRE PROTECTION AND SPRINKLER WORK SHALL BE PERFORMED BY LANDLORD- APPROVED FIRE PROTECTION CONTRACTOR AT THE TENANT'S EXPENSE. CONTRACTOR SHALL SUBMIT CERTIFIED AIR BALANCE REPORT INCLUDING ALL ASSOCIATED AIR TEMPERATURES AND PRESSURES AS APPLICABLE. SEND TWO COPIES TO OWNER FOR APPROVAL — 1 SEPARATE PERMIT REQUIRED FOR: 0 Mechanical EYEIectricai [YPlumbing [ ' Gas Piping City of Tukwila BUILDING DIVISION r UGO G N w Et Z O O e r 2 O w I"1-.O w � � w • J O >- LLI t I- C/) w I— a U 0 VJ 0 LL.I w J N . 0 0 $ ▪ r-- �� LO a i D zo Z ID W E r; cr o- N w o' ❑ a w echanical + electrical consulting engineering 27 AUGUST 2007 Minneapolis. Minnesota 55402-1540 nh 50 South Sixth Street /Suite 1100 DOCUMENT DATE CHECKED BY FA ISSUED FOR DRAWN BY PROJECT SELECT COMFORT SOUTHCENTER MALL SUITE # 1005 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 PROJECT NO. 408865-13 I jk8 1 3C1 31aa L0/60/0 1. NOISIA3b PER L.L. /ARCH P ON ««GC< WORK INCLUDED: EACH CONTRACTOR SHALL VERIFY LANDLORD REQUIREMENTS. BID AND INSTALLATION SHALL BE BASED ON SUCH REQUIREMENTS. DRAWINGS AND SPECIFICATIONS. MECHANICAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES ON THE PROJECT PREVENTING UNNECESSARY CONFLICTS OR DELAYS DURING CONSTRUCTION. IF FOR ANY REASON EXISTING EQUIPMENT TO BE RE —USED NEEDS REPLACEMENT PARTS, THIS COST IS TO BE COVERED UNDER ORIGINAL CONTRACT AMOUNT AND WILL NOT BE ACCEPTED AS AN EXTRA COST OR EXPENSE. CONTRACTOR MUST INSPECT ALL EQUIPMENT TO BE RE -USED AT TIME OF BIDDING OR NEGOTIATING PERIOD. CONTRACTOR SHALL EXAMINE THE SITE, COMPARE IT WITH DRAWINGS AND SPECIFICATIONS AND BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO ALLOWANCE WILL SUBSEQUENTLY BE MADE IN BEHALF OF THIS CONTRACTOR BY REASON OF ANY ERROR ON HIS PART. CODES AND STANDARDS: ALL CODES, ORDINANCES, RULES, REGULATIONS, ORDERS, AND OTHER LEGAL REQUIREMENTS WITH WHICH COMPLIANCE IS REQUIRED BY GOVERNING AUTHORITIES SHALL BE ADHERED TO. TENANTS CONTRACTORS SHALL VERIFY WITH HVAC PLAN TO COORDINATE THE REQUIREMENT OF PLENUM RATED FIXTURES, PIPING, WIRING, ETC. FAILURE TO DO SO COULD RESULT IN THE REMOVAL AND REPLACEMENT OF THESE ITEMS AT NO ADDITIONAL COST TO THE TENANT. SCOPE A. THE WORK COVERED BY THIS SPECIFICATION INCLUDES THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM. B. THE WORK TO BE PERFORMED UNDER THE HEATING AND AIR CONDITIONING SPECIFICATIONS AND DRAWINGS CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION OF ALL HEATING AND AIR CONDITIONING SYSTEM FOR TENANT SPACE. THE WORK SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, THE FOLLOWING: 1. HEATING /COOLING UNITS 2. TOILET ROOM EXHAUST SYSTEMS . 3. AUTOMATIC, TEMPERATURE CONTROL 4. DUCTWORK AND AIR CONTROL 5. USE OF CRANE TO PLACE ROOF TOP EQUIPMENT (WHEN REQUIRED) GENERAL: A. THIS SPECIFICATION IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO PROPERLY INSTALL, ALTER, ADJUST, AND PUT IN OPERATION, THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM. B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE WORK INCLUDED IN THIS CONTRACT. LAWS, ORDINANCES AND REGULATIONS: A. ALL SYSTEMS IN ALL AND /OR PART SHALL CONFORM TO ALL PERTINENT LAWS, ORDINANCES AND REGULATIONS OF ALL BODIES HAVING JURISDICTION, AT ALL GOVERNING LEVELS, NOTWITHSTANDING ANYTHING IN THESE DRAWINGS OR SPECIFICATIONS TO THE CONTRARY. IN CASE OF CONFLICT BETWEEN GOVERNING LEVELS, THE MORE STRINGENT LAWS SHALL APPLY. B. THE CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH HIS WORK. MATERIALS AND EQUIPMENT: A. ALL MATERIALS SHALL BE NEW AND SHALL BE OF THE TYPE AND SHALL MEET THE CAPACITIES OF EQUIPMENT SPECIFIED ON THE DRAWINGS. ALL MATERIALS AND EQUIPMENT UTILIZED SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA. B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS. C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED. WORKMANSHIP: A. ALL HEATING EQUIPMENT SHALL BE INSTALLED IN A WORKMANLIKE MANNER MEETING THE ACCEPTED STANDARDS OF THE HEATING INDUSTRY. THE WORK SHALL BE DONE BY SKILLED HEATING CRAFTSMAN, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF ASHRAE AND /OR THE SMACNA MANUAL. CUTTING, PATCHING AND PAINTING: UNLESS OTHERWISE DIRECTED BY THE LANDLORD CRITERIA, THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING REQUIRED IN CONNECTION WITH HIS WORK. ALL FINISHED SURFACES THAT ARE CUT SHALL BE REPLACED IN KIND SO THAT THERE ARE NO VISIBLE EVIDENCE OF "PATCH ". PAINTING OF MECHANICAL WORK SHALL BE BY PRIME CONTRACTOR. ALL EQUIPMENT WHICH HAS HAD THE FINISH DAMAGED BY INSTALLATION OR TRANSPORTATION SHALL BE REFINISHED. ROOF AND OTHER PENETRATIONS: EACH CONTRACTOR REQUIRING OPENINGS IN THE ROOF OF THE BUILDING STRUCTURE (WHERE REQUIRED) SHALL MAKE ARRANGEMENTS WITH THE LANDLORD FOR SUCH OPENINGS. PROCEDURE AND COST ARRANGEMENTS SHALL BE OUTLINED IN THE LANDLORD CRITERIA. COMPLY WITH ALL LANDLORD REQUIREMENTS. ALL ROOF PENETRATIONS SHALL BE ARRANGED TO PROVIDE A WEATHER —TIGHT INSTALLATION. THE INSTALLATION SHALL INCLUDE, WHERE REQUIRED, VENTILATING COLLARS TO GIVE PROPER CLEARANCE FROM COMBUSTIBLE ROOFS, FLOORS, CEILINGS OR OTHER SUCH STRUCTURES. FIRE -- PROOFING SHALL BE PROVIDED USING MATERIALS CONFORMING WITH MUNICIPAL CODES AND ORDINANCES. MECHANICAL UNIT: MECHANICAL FIRE PROTECTION DUCTWORK: A. ALL DUCTWORK SHALL BE INSTALLED AS SHOWN ON MECHANICAL DRAWINGS. B. THE DUCTWORK SHALL BE CLEAR INSIDE OF THE SIZES SHOWN ON THE DRAWINGS. ALL DUCTS TO BE SHEET METAL DUCTS AS PER ASHRAE AND SMACNA GUIDLINES. C. FLEXIBLE DUCTS SHALL BE LIMITED TO 5'—O" MAX. FOR CONNECTION TO AIR DEVICES. D. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 GALVANIZED SHEET METAL WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5' —O" ON CENTER. DUCTWORK MATERIALS SHALL BE PER CURRENT MECHANICAL CODE. DUCTWORK INSULATION: SUPPLY FROM THE AIR CONDITIONING UNIT SHALL BE WRAPPED WITH 1 -1/2" THICK 1 LB /CUFT FIBERGLASS, FOIL BACKED INSULATION TO PREVENT CONDENSATION. GRILLES AND DIFFUSERS: GRILLES AND DIFFUSERS SHALL BE AS MANUFACTURED BY KREUGER, HART AND COOLEY, BARBERCOLMAN, OR TITUS. EACH IS TO BE HUED WITH A VOLUME DAMPER. (OPPOSED BLADE DAMPER) TESTING AND BALANCING CERTIFIED (AABC OR NABB) INDEPENDENT TESTING COMPANY TO TEST AND BALANCE SYSTEM TO CFM AS SPECIFIED. REPORT RESULTS TO TENANT AND ARCHITECT. GUARANTEE: A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE OF OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD. B. THE GUARANTEE SHALL INCLUDE RESTORATION OF ITS ORIGINAL CONDITION OF ALL ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE. C. ALL SUCH REPAIRS AND /OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE CONVENIENCE OF THE OWNER. SUBSTITUTIONS: A. APPROVALS OF SUBSTITUTIONS FOR "APPROVED EQUAL ", MUST BE IN WRITING AND SUBSTITUTION MUST BE APPROVED BEFORE INSTALLATION. INSTALLATION WITHOUT PRIOR APPROVAL MAY RESULT IN CONTRACTOR REMOVING SUBSTITUTION AND REPLACING IT WITH SPECIFIED ITEM AT HIS EXPENSE. B. APPROVAL MAY BE GIVEN BY ARCHITECT, ENGINEER OR OWNER. TEMPERATURE CONTROL: FURNISH AND INSTALL NEW COMPATIABLE THERMOSTAT AS LISTED BELOW. A. TEMPERATURE CONTROL SHALL BE BY A WALL MOUNTED HEATING /COOLING THERMOSTAT, WITH SUBBASE HAVING SELECTOR SWITCHES FOR "ON /AUTO" AND "HEAT /OFF /COOL" TEMPERATURE RANGE FROM 50 DEGREES F. TO 90 DEGREES F. B. THIS STANDARD SYSTEM TO BE USED UNLESS SPECIAL CONTROL SYSTEM IS CALLED FOR OR SHOWN ON DRAWINGS. A. B. NEW ENVIRO—TEC 1018 W/ 1/2 HP MOTOR AND 5KW HEATING COIL, SEE SCHEDULE. VAV TERMINAL UNIT SEQUENCE OF OPERATION: COOLING CYCLE AT THE DESIGN COOLING CONDITION, THE PRIMARY AIR VALVE IS HANDLING THE MAXIMUM SCHEDULED PRIMARY AIRFLOW CAPACITY WHILE THE UNIT FAN IS OFF. AS THE COOLING LOAD DECREASES, THE PRIMARY AIR VALVE THROTTLES TOWARD THE MINIMUM SCHEDULED PRIMARY AIRFLOW CAPACITY. HEATING CYCLE UPON A DROP IN SPACE TEMPERATURE BELOW THE SETTING OF THE THERMOSTAT, THE PRIMARY AIR VALVE SHALL THROTTLE TO THE MINIMUM PRIMARY AIRFLOW CAPACITY WHILE THE UNIT FAN IS ON. IF THE DAMPER REACHES THE MINIMUM SET POINT THE DUCT HEATER SHALL TURN ON UNTIL THE CALL FOR HEAT IS SATISFIED. A EXECUTION — INSTALLATION: LANDLORD NOTES LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST PREQUIREMENTS OF NFPA 13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT SHALL CONNECT A FIRE SPRINLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISSES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF TE STATE OF WASHINGTON, CITY OF OF TUKWILA FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING DESIGN SPECIFICATIONS. SPRINKLER LAYOUT AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA 13. ALL SPRINKLER HEADS SHALL BE CONCEALED WITH COVER PLATES IN PUBLIC AREAS. ADD RECESSED SPRINKLER HEAD IN REAR ALCOVE CEILING. A. GENERAL CONTRACTOR TO VERIFY MALL SPRINKLER CONTRACTOR REQUIREMENTS AND USE SPECIFIED CONTRACTOR IF REQUIRED. B. INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 13. INSTALL SPRINKLER PIPING PRODUCTS WHERE REQUIRED IN ACCORDANCE WITH RECOGNIZED PRACTICES TO ENSURE THAT FIRE PROTECTION SPRINKLER PIPING COMPLIES WITH GOVERNING REQUIREMENTS AND SERVES THE INTENDED PURPOSES. C. EXAMINE OTHER WORK SHOWN ON THE DRAWINGS . AND CONDITIONS AT THE JOB SITE. COORDINATE THE ROUTING OF WORK WITH OTHER TRADES TO AVOID INTERFERENCE WITH OTHER INSTALLATIONS. D. PIPE ROUTING AND SPRINKLER HEAD LOCATIONS SHALL BE LOCATED AS REQUIRED TO AVOID EQUIPMENT, PLUMBING, HEATING AND AIR CONDITIONING PIPING, DUCTWORK, LIGHTING FIXTURES, ELECTRICAL CONDUITS AND BUS DUCTS AND SIMILAR WORK. E. PROVIDE PIPE OFFSETS AS REQUIRED TO COMPLETE THE INSTALLATION. MODIFY PIPE, PREFABRICATED PIPING, PIPE HANGERS AND OTHER COMPONENTS AS REQUIRED TO FIT THE JOB SITE CONDITIONS. CLEANING AND FLUSHING: PRIOR TO CONNECTING SPRINKLER PIPING FOR FLUSHING, FLUSH WATER FEED MAINS, LEAD —IN CONNECTIONS AND CONTROL PORTIONS OF SPRINKLER PIPING. AFTER FIRE SPRINKLER PIPING INSTALLATION HAS BEEN COMPLETED AND BEFORE PIPING IS PLACED IN SERVICE, FLUSH ENTIRE SPRINKLER SYSTEM UNDER PRESSURE, AS REQUIRED TO REMOVE FOREIGN SUBSTANCES AS REQUIRED BY NFPA 13. CONTINUE FLUSHING UNTIL WATER IS CLEAR AND CHECK TO ENSURE THAT DEBRIS HAS NOT CLOGGED SPRINKLERS. TESTING: A. AFTER FLUSHING SYSTEM, TEST FIRE SPRINKLER PIPING HYDROSTATIC ALLY IN ACCORDANCE WITH NFPA 13, AT NOT LESS THAN 200 PSI OR AT 50 PSIG. CHECK SYSTEM FOR LEAKAGE AT JOINTS. MEASURE HYDROSTATIC PRESSURE AT LOW POINT OF EACH SYSTEM OR ZONE BEING TESTED. B. REPAIR OR REPLACE PIPING SYSTEM AS REQUIRED TO ELIMINATE LEAKAGE IN ACCORDANCE WITH NEPA STANDARDS FOR "LITTLE OR NO LEAKAGE" AND RETEST AS SPECIFIED TO DEMONSTRATE COMPLIANCE. SPRINKLER MAINS AND BRANCHES A. PIPING MATERIAL: BLACK STEEL, SCHEDULE 40 OR LIGHTWEIGHT SPRINKLER PIPE, SCHEDULE 10 ASTM A 135 (IF ALLOWED BY LANDLORD AND LOCAL AUTHORITIES). B. FITTINGS: THREADED, CLASS 175. MECHANICAL COUPLINGS AND TEES OF A ROLLED GROOVED TYPE WILL BE ACCEPTED (IN LIEU OF THREADED) IF BOTH U.L. LISTED AND FIRE MARSHAL APPROVED. INSTALLATION: C. ALL SPRINKLER PIPING SHALL BE CONCEALED UNLESS OTHERWISE INDICATED. ALL PIPING SHALL BE LOCATED TO AVOID INTERFERENCE WITH ALL OTHER ELEMENTS ABOVE CEILINGS, ETC. D. SUPPORT ALL HORIZONTAL PIPING AT NOT GREATER THAN 10 FEET INTERVALS, EXCEPT PIPES OF SIZE 1-1/2" AND LARGER WHICH SHALL BE SUPPORTED AT NOT GREATER THAN FIFTEEN FEET INTERVALS, WITH APPROVED SWIVEL SPLIT RING HANGERS WITH ROD SUPPORTS AND SWAY BRACES AT EVERY THIRD HANGER. E. ALL SPRINKLER PIPING SHALL BE INSTALLED SO THAT IS CAN BE THOROUGHLY DRAINED AND WHERE PRACTICAL, ARRANGE TO DRAIN THE MAIN VALVE. SPRINKLER HEADS A. SPRINKLER HEADS IN AREAS WITH LAY —IN AND DRYWALL CEILINGS SHALL BE RECESSED TYPE , 165 DEGREE RATED, CHROME PLATED HEAD WITH ESCUTCHEON COLOR TO MATCH CEILING COLOR, VERIFY EXACT COLOR WITH ARCHITECT. B. SPRINKLER HEADS IN AREA OF NO CEILING SHALL BE CHROME PLATED UPRIGHT. C. ALL SPRINKLER HEADS SHALL BE 1/2" ORIFICE, RATED AT 165 DEGREES WITH A K— FACTOR OF 5.65. D. ALL SPRINKLER HEADS THAT ARE TO REMAIN AND BE REUSED SHALL BE PROTECTED DURING CONSTRUCTION AND CLEANED THOROUGHLY TO INSURE THAT THEY ARE CLEAR OF PAINT AND DEBRIS AND ARE IN GOOD WORKING CONDITION, PRIOR TO PROJECT CLOSEOUT. E. ALL SPRINKLER HEADS SHALL BE INSTALLED IN ACCORDANCE TO NFPA 13 AND ALL LOCAL CODES AND AUTHORITIES HAVING JURISDICTION. A PLUMBING SCOPE: A. THE WORK TO BE PERFORMED UNDER THE PLUMBING SPECIFICATIONS AND DRAWINGS CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION OF ALL PLUMBING SYSTEMS FOR TENANT SPACE. THE WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: 1. COLD AND HOT WATER SYSTEMS 2. DRAINAGE AND VENT SYSTEMS 3. INSULATION GENERAL: A. THIS SPECIFICATIONS IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO PROPERLY INSTALL, ALTER, ADJUST, AND PUT INTO OPERATION, THE COMPLETE PLUMBING SYSTEM . B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE WORK INCLUDED IN THIS CONTRACT. WORKMANSHIP: ALL WORK MUST BE DONE IN A WORKMANLIKE MANNER TO THE COMPLETE SATISFACTION OF THE ENGINEERS AND SHALL BE PERFORMED BY QUALIFIED MECHANICS. A. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, AND SHALL CONFORM TO THE GRADE, QUALITY AND STANDARDS SPECIFIED HEREIN. ALL MATERIALS AND EQUIPMENT UTILIZED SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA. B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS. C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED. LAW, ORDINANCES AND REGULATIONS: A. ALL MECHANICAL SYSTEMS IN ALL AND /OR PART SHALL CONFORM TO ALL PERTINENT LAWS, ORDINANCES AND REGULATIONS AND ALL BODIES HAVING JURISDICTION, AT ALL GOVERNING LEVELS, NOTWITHSTANDING IN THESE PLANS AND SPECIFICATION TO THE CONTRARY. IN CASE OF CONFLICT BETWEEN GOVERNING LEVELS, THE MORE STRINGENT LAWS SHALL APPLY. B. CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH HIS WORK. C. WHERE APPLICABLE, ALL MATERIAL SHALL BEAR THE THE NATIONAL BOARD OF FIRE UNDERWRITER'S SEAL OF APPROVAL. CERTIFICATES TO THIS EFFECT TO BE FURNISHED TO ARCHITECT TO BE TO ARCHITECT UPON REQUEST. ESCUTCHEONS: A. ALL EXPOSED PIPES, EXCEPT AS OTHERWISE DESCRIBED, PASSING THRU WALLS, FLOORS, CEILINGS, ETC. IN FINISHED SPACES, SHALL BE PROVIDED WITH SOLID PATTERN HEAVY CEILING, FLOOR OR WALL ESCUTCHEONS WITH SET SCREW. ESCUTCHEONS AND PLATES SHALL BE OF STEEL OR MALLEABLE IRON WITH PRIME COAT READY FOR PAINTING. ESCUTCHEONS WILL NOT BE PROVIDED WHERE SLEEVES INTENTIONALLY EXTEND ABOVE FINISHED FLOOR. B. ALL EXPOSED PLUMBING SHORT BRANCH CONNECTIONS TO FIXTURES AND /OR EQUIPMENT PASSING THROUGH WALL OR FLOORS SHALL BE EQUIPPED WITH PRESS BRASS, CHROMIUM PLATED, SOLID TYPE ESCUTCHEONS. GUARANTEE: A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD. B. THE GUARANTEE SHALL INCLUDE RESTORATION TO ITS ORIGINAL CONDITION OF ALL ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE. C. ALL SUCH REPAIRS AND /OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE CONVENIENCE OF THE OWNER. TEMPORARY SERVICES: A. THE CONTRACTOR, AT HIS OWN EXPENSE AND COST, SHALL INSTALL, OPERATE, PROTECT AND MAINTAIN THE RESPECTIVE TEMPORARY SERVICES AS REQUIRED BY HIS WORK. TEST OF PIPING AND SYSTEM: A. THE SYSTEMS OF PIPING AS INSTALLED BY THIS CONTRACTOR MUST BE TESTED WITH WATER OR AIR AND PROVEN TIGHT TO THE SATISFACTION OF REPRESENTATIVES OF THE OWNER. TESTING INSTRUMENTS MUST BE FURNISHED BY THE PLUMBING CONTRACTOR. B. TEST MUST BE MADE WITH WATER, EXCEPT WHEN THERE IS DANGER FROM FREEZING, THEN TESTS MAY BE MADE WITH AIR. WOODEN PLUGS ARE NOT TO BE USED IN MAKING TESTS. STERILIZATION OF DOMESTIC WATER SYSTEM: A. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE A.W.W.A SPECIFICATIONS C601 -53T_ SOIL WASTE AND VENT PIPING: A. SOIL WASTE PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE, BELL & SPIGOT TYPE AS REQUIRED. B. VENT PIPE SHALL BE SERVICE WEIGHT CAST IRON BELL & SPIGOT TYPE AS REQUIRED PER LOCAL CODE. INSULATE —ALL LINES (ABOVE CEILING /IN WALLS INCLUDED): A. INSULATION ON COLD WATER, HOT WATER, CONDENSATE LINES, ETC., SHALL BE ARMAFLEX II, OR APPROVED EQUAL, WITH THICKNESS AS REQUIRED. MINIMUM THICKNESS IS 1/2" INCH. B. INSULATION ON ROOF DRAINS AND ROOF DRAIN LEADERS SHALL BE FIBERGLASS WITH MULTI — PURPOSE WRAPPING. SUBSTITUTIONS: A. SUBSTITUTIONS WILL BE CONSIDERED FOR "OR EQUAL" BUT MUST BE APPROVED IN WRITING, BY OWNER, ARCHITECT OR ENGINEER, PRIOR TO INSTALLATION. B. IF, AFTER PLANS ARE COMPLETED, AUTHORITIES RULE THAT HANDICAPPED RESTROOM IS REQUIRED, BUT NOT SHOWN, USE AMERICAN STANDARD 'CADET —HI" WATER CLOSETS AND SET LAVATORY AT PROPER HEIGHT WITH LEVER HANDLES. (VERIFY ALL FINAL EQUIPMENT SPECS WITH PLUMBING DRAWING). WATER PIPING: A. WATER PIPING UNDER FLOOR SHALL BE TYPE "K" SOFT COPPER WITH SILVER SOLDER JOINTS. B. WATER PIPING ABOVE FLOOR SHALL BE TYPE "L" HARD D COPPER WITH LEAD FREE SOLDER JOINTS. W U w I- I- w W z 0 c<i W F- 1- \ 0 , 0 e C \ RECEIVED CITY OF TUKWILA OCT 22 2001 PERMIT CENTER IF YOU HAVE ANY QUESTIONS REGARDING THE MECHANICAL PLANS PLEASE CALL THE MECHANICAL DESIGNER. DESIGNER: CRAIG ENGLE 612- 465 --7680 OR SUPERVISOR: GREG STEINMETZ 612-465-7684 MO7ZZS F- U) W I— Q U 0 CO v) 0 w_ } w J 7 n 0 o' 0 to in I- N 0 Cr. W Z o z z W ,� - ^ a s N zC. w x wLL SPECIFICATIONS 27 AUGUST 2007 DOCUMENT DATE CONCEPT BY CHECKED BY 0 2007 Lam ASSOCIATES, LTD. ALL RIGHTS RESERVED ISSUED FOR DRAWN BY