Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-228 - BOEING #9-101
BOEING #9 -101 9725 EAST MARGINAL WAY S M07 -228 Parcel No.: 0003400018 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 9725 EAST MARGINAL WY S TUKW Contact Person: Name: KEVIN ALMON Address: 14630 SE 213 ST , KENT WA Contractor: Name: VITAL MECHANICAL SERVICE INC Address: 14630 SE 213 ST , KENT WA Contractor License No: VITALMS964MM DESCRIPTION OF WORK: MOVE (3) EXISTING VAV BOXES, MOVE (9) DIFFUSERS, REPLACE (9) T -STATS AND BALANCE. Value of Mechanical: $9,200.00 Type of Fire Protection: BOEING #9 -101 9725 EAST MARGINAL WY S , TUKWILA WA BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 City..if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * *continued on next page ** M07 -228 Permit Number: M07 -228 Issue Date: 12/11/2007 Permit Expires On: 06/08/2008 Phone: Phone: 253 630 -6933 Phone: Expiration Date: 07/21/2008 Fees Collected: $269.58 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP/1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 12 -11 -2007 Permit Center Authorized Signature: Signature: doc: IMC -10/06 City of Tukwila Print Name: Xe (c4J t 1 ` ""tom Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -228 Issue Date: 12/11/2007 Permit Expires On: 06/08/2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinance: governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the performan of v}cprk. I am authorized to sign and obtain this mechanical permit. Date: / — /l This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 -228 Printed: 12 -11 -2007 Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #9 - 101 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -228 Status: ISSUED Applied Date: 10/25/2007 Issue Date: 12/11/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M07 -228 Printed: 12 -11 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: 1Z-1/---4 7 doc: Cond -10/06 M07 -228 Printed: 12 - 11 - 2007 E -Mail Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwatukwila.wa.us Name: ewcA.J i4 -0 Mailing Address: pi D be" 713-0-4 St Cam" Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Q: Appliations'Forms- Applications On Line 3 -2006 - Mechanical Permit Application.doc Revised: 4-2006 bh Mechanical Perini P roject No. MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 0 0 'CO 1 Floor: E-{ I Y Tenant Name: 69e-VA" New Tenant: ❑ .... Yes ❑ ..No Property Owners Name: Mailing Address: Site Address: e t'? ZS 649( Y14 6 .. e . w - tOki S Suite Number: I --to ► City CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 25 - Co30 - (. � 3 City 1'6030 66 2c 3 fit- Imo... - / ? go'Z City Contact Person: 04J *1"- -' Day Telephone: E -Mail Address: ((Lvyeu dog,,-,r•-• () u tlid 1.„04.44.+..„.4,,x. co -Fax Number: Contractor Registration Number: Ma All j (oc{ 0.4. vtit- Expiration Date: For office use only) State wA `i$O`f Z. Zip State Zip Fax Number: IS 6230 _3 5C State Zip ZS'S &30 'qe 3 2f3 - 6 7-3l ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Recor City Day Telephone: Fax Number: State Zip ` ENGINEER OF RECORD - All plans must be wet stamped by City Day Telephone: Fax Number: State Zip Page 1 of 2 Unit Type:, Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Ap • ce Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU epair or A • to Heat/Refrig/Cooling \_Sytem Incinerator - Domestic Emergency Generator Air H ii 1ing'lTnit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment i Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): o 5 Use: Residential: New .... ❑ Commercial: New .... ❑ Fuel Type: Electric ❑ Gas ....0 BUILDING OWNER AUTH O ZED AGENT: Signature: Print Name: Mailing Address: Date Application Accepted: Q: \ApplicationsWorms- Applications On Line\3 -2006 - Mechanical Permit Application.doc Revised: 4 bh t 8 0`c°cs d M c1e. Replacement .... ❑ Replacement ...`CJ Other: Indicate type of mechanical work being installed and the quantity below: Cte Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. ( (elo 30 se u3 Sd- Date: / G — 25 — o g Day Telephone: 74 - (30 `Cvi( 33 City State Zip Date Application Expires: Staff Initials: _ i...... 4 age 2 of 2 Doc: RECSETS -06 RECEIPT NO: R07 -02346 Initials: WER User ID: 1655 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: VITAL MECHANICAL SERVICE, INC. SET ID: 1025 SET NAME: BOEING #9 -101 SET TRANSACTIONS: Set Member Amount M07 -228 269.58 PG07 -206 190.00 TOTAL: 459.58 TRANSACTION LIST: Type Method Description SET RECEIPT Amount Payment Check 1290 459.58 TOTAL: 459.58 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES Account Code Current Pmts 000/322.100 221.66 000/345.830 47.92 000/322.100 190.00 TOTAL: 459.58 Payment Date: 10/25/2007 Total Payment: 459.58 COMMENTS: 0 /.269( 4 -/& ) - Corpip/F / _ L.,A ( .9, ,, , ,- /r/ y C-A9 T 5>=- J- Pc "/1!,2,,,,, I, - ,vv hnlJ7 4q /-� �G/ am( Date Called: Special Instructions: )7 "..k/ - /fb,J -- A//4 7 9 / /_Q V p.m. 7 idee.'41 i "/ ( °'.4 //7 ih.i1 /' Pro' t: .6 o i � 9- /n / Type of I pection: i tix Ad�ress25 r� CC 77 /-� �G/ am( Date Called: Special Instructions: Date Wanted: Z Ca.:- / /_Q V p.m. Requester: P ' d '' � —7 3 -64/s_ y 7-z2 8 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Date: .ter I / —/ — .00 REINSPECTION'EE REQUIRED. Prior to inspection. fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Date: • 7 ACTIVITY NUMBER: M07 -228 DATE: 10 -25 -07 PROJECT NAME: BOEING #9 -101 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: J v Buil ing l'vision l(f Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Notation: Documents/routing slip.doc 2 -28 -02 REVIEWER'S INITIALS: f , PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 6(( Ilk It -Ik 1 Fire Prevention Structural Incomplete ❑ TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ Permit Coordinator ❑ Planning Division DUE DATE: 10-30-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DATE: n DUE DATE: 11-27-07 APPROVALS OR CORRECTIONS: Approved n Approved with Conditions i Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License VITALMS964MM Licensee Name VITAL MECHANICAL SERVICE, INC. Licensee Type CONSTRUCTION CONTRACTOR UBI 602410867 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 14630 SE 213TH STREET Address 2 City KENT County KING State WA Zip 98042 Phone 2536306933 Status ACTIVE Specialty 1 AIR CONDITIONING Specialty 2 UNUSED Effective Date 7/21/2004 Expiration Date 7/21/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date ALMON, KEVIN LEWIS PRESIDENT 07/14/2004 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 CBIC SG8008 07/20/2006 Until Cancelled $6,000.00 07/11/2006 DEVELOPERS SURETY & Until Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= VITALMS964MM 12/11/2007 DRAW! \G I \DEX SHEET N0. DRAWING N0. SHEET TITLE REV. NO. DATE Al 9- 101 -A1 TITLE SHEET C 07.03.07 1A01 9-101-1A01 COMPOSIT FIRST FLOOR PLAN, EGRESS PATH C 07.03.07 411 A45OR 9 -101 -M 1 A45OR MEZZ. H14 FLOOR PLAN, REMOVAL A 07.03.07 M1A450 9 -101- M1A450 MEZZ. H14 FLOOR PLAN • . A 07:03.07 1A23 9-- 101 --1A23 FIRST FLOOR PLAN H 07.03.07 M1A451 9- 101-- M1A451 MEZZ. H14 ENLARGED PARTICAL PLAN A 07.03.07 M1A465 9- 101-- M1A465 MEZZ. WALL & FLR FINISH PLAN C 07.03.07 M1A370 9 -101- M1A370 MEZZ. INTERIOR ELEVATIONS & SECTIONS A 07.03.07 M1A5O1 9- 101- M1A5O1 MEZZ. MISC. DETAILS & SECTIONS D 07.03.07 M1A503 9- 101-- M1A503 MEZZ. KITCHENEIIE ELEVATION & SECTIONS . A 07.03.07 M1A351 9--101- M1A351 DOOR SCHEDULE C 07.03.07 • • i (�:`: f .� II If -. Title ih�� I VICI \IITY MAP 99 Do 99 FROM SEATTLE -- TACOMA AIRPORT DEVELCPvE EAST MARGINAL WAY CORPORATE PARK TAL FROM DOWNTOWN SEATTLE CE 599 TUKWILA vTER PROJECT SITE 900 EXIT 157 EXIT 158 FROM KENT & AUBURN NO SCALE EXIT 157 900 BOEING WORKPLACE SERVICES BUILDING 9 -101 �, JOB #160621 -00 9 -1x1.1 H14 MEZZANINE OFFICE RENOVATION BU'V BY APPROVED RWS LMC LMC 03.30.06 TWH 05.02.07 07.03.07 DATE SYM AREA MAP BUILDING ADDRESS: 9725 EAST V1ARG1 \AL WAY SOUTH TL <WI LA, WAS H I \ GTO 9 - 78 9--35 9 -52 9101 BUIDI G LOCATIO PROJECT SITE NO SCALE REVISION BY APPROVED BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 DATE Z, L Atirar.EzAw GE ERAL I\ OTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO JOHN MURDOCH AT BUILDING 9 -51.2 COLUMN M2., AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHEC LIST CHECK BOX • THESE DRAWINGS CONFORM TO THE 2006 I.B.C. CODES AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ® ROOMS LABELED PER OCCUPANCY PER I.B.C. 302.1. 1 BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ❑ NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. GENERAL PERMIT (SHELL & CORE) ❑ 4 SETS OF STRUCTUAL REPLACEMENT DRAWINGS • 2. TENANT IMPROVEMENT (NON-STRUCTURAL): ❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS. ❑ 4. MECHANICAL, 4 COMPLETE SETS. ❑ 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: 1. RENOVATE EXISTING MEZZANINE MEN'S & WOMAN'S RESTROOMS. 2. REPLACE CEILING TILES AND FIXTURES USING EXISTING CEILING GRID. 3. PROVIDE 19 LINEAL FEET OF DEMOUNTABLE WALL. 4. REPLACE CABINETRY IN KITCHENETTE. 5. RENOVATE ROOM FINISHES. SYM A C REVISION 9 -101.1 AHU #1H15A 9 -101 M16 OFFICE RENOVATION J #547077 --03 J #160620 -00 9 -101 H14 MEZZ OFFICE RENOVATION J #160621 -00 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M. DITTMAR CHECKED ENGINEER CHECKED APPROVED APPROVED REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. 1 NOTE: Revisions will require a new plan submittal and may include additional plan review fees DATE 03.08.02 SUBTITLE TITLE Plan review approval la mat loaraara and omissions. Approval of canslrudton doom* don nataulr Od the violation of any adopted cads orodium Asceipt of approved Field la admaradged: CODE SU V v1ARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS TUNNEL FIRST FLOOR MEZZANINE EFFECTED AREA BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE TUKWILA 2006 I.B.C. CODES AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B AND GROUP F, DIVISION 1 (OFFICE AND FACTORY) TYPE B, NON - COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 295,878 (UNLIMITED PER IBC _ 507.3) 713,829 . 1,116,306 50,910 713,829 55,689 2,677 SF OF OFFICE SPACE 111 FT. MAXIMUM 2 OVERALL (NO CHANGES) BARRIER FREE FULLY AUTOMATIC, F/S CLASS• SPRINKLERS THROUGHOUT 3 CITY OF RECEIVED J LA OCT 2 5 2007 PERMIT CENTER MECHANICAL MASTER SEPARATE PERIv1iT REQUIRED FOR: nical ❑ Mecha ! Electrical Ni lumbing t Gas Piping City of Tukwila BUILDING DIVISION TITLE SHEET JOB #160621-00 BUILDING 9 -101 i Permit No. By FILE COPY 06.20.07 CURRENT REVISION '4160621 -00 SHEET JOB NO. DWG NO. Al Z SYMBOL 160621 -00 9- 101 -A1 DATE COMP NO. • 07.03.07 SCALE: 1/2 "= 1' -0" M11G13 M1A370 M11G13 M1A450 M1A451 [M1 CONSTRUCTION � :c:::L NEW BOBRICK 8 -165 3642 36" W X 42" H MIRROR W /STAINLESS STEEL CHANNEL FRAME (TYP). MOUNT BOTTOM OF MIRROR 2" FROM TOP OF BACKSPLASH. CENTER MIRROR ON SINK. NEW GLOBAL STAINLESS STEEL FLOOR MOUNTED TOILET PARTITIONS. #4 SATIN FINISH. MANUFACTURER WILL SUPPLY SHOP DRAWINGS FOR SUPPORT POINTS. MOUNT COAT HOOK ON BACK OF TOILET PARTITION DOOR AT +54 "AFF (TYP). 1 NEW BOBRICK CONTRA SERIES RECESSED WASTE RECEPLACLE, STAINLESS STEEL. B- 43644. OTES (CC DASHED LINE - LAMINATE SURFACED COUNTER TOP KNEE BRACE SUPPORT (TYP). NEW BOBRICK B -165 2436 24" W X 48" H MIRROR W /STAINLESS STEEL CHANNEL FRAME (TYP). MOUNT BOTTOM OF MIRROR 2" FROM TOP OF BACKSPLASH. CENTER MIRROR ON SINK. INSTALL NEW HOLLOW METAL DOOR FRAME, DOOR , SIGNAGE AS INDICATED & HARDWARE. REINSTALL TOWEL DISPENSER �] NON SPECIFIC, NOTE APPLIES TO ROOM. SPECIFIC, NOTE APPLIES TO SPECIFC ITEM. 1. COORDINATE WORK WITH ALL TRADES REQUIRED TO COMPLETE THE WORK. 2. LEAVE WORK & STAGING AREAS CLEAN & UNCLUTTERED AT THE END OF EACH DAY AND THE END OF THE JOB. 3. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PROPERTY. 4. REMOVE ALL TOOLS & MATERIALS FROM THE WORK AREA, 5. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. THE GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS. IF ANY DISCREPANCIES EXIST BETWEEN THE PROPOSED & EXISTING CONDITIONS OTHER THAN THAT INDICATED ON THE DRAWINGS, THE GENERAL CONTRACTOR SHALL NOT PROCEED WITH THAT WORK UNTIL A CORRECTIVE PROCEDURE HAS BEEN IDENTIFIED & APPROVED BY THE BOEING CONSTRUCTION MANAGER. 7. MOUNT ALL TOILET ACCESSORIES, PARTITIONS, & MIRRORS AS DETAILED ON SHEET M1A370. PROVIDE BACKING FOR THESE ITEMS IN NEW WALLS. 8. SEE DETAIL SHEET M1A370 FOR RESTROOM 7. SEE DOOR SCHEDULE, SHEET M1A351. CO STRUCTIO TILE FLOORING: INSTALL 3" THERMAFIBER INSULATION BATT, FRICTION FIT IN STUD SPACE, IN ALL BATHROOM WALLS, FULL HEIGHT. INSTALL NEW WALL SHEATHING, 5/8" THICK DENS - SHIELD TILE BACKER FLOOR TO HARD CAP CEILING © RESTROOM SIDE OF WALL. TAPE, SAND, & SEAL, PREP FOR PAINT. HAZ-MAT TO REMOVE EXISTING VINYL FLOOR TILE & MASTIC. INSTALL DALTILE "VERANDA" COLORBODY PORCELAIN FIELD TILE, COLOR #P -506, "LEATHER" 3/8" 13" X 13" NOMINAL SIZE. QUARTER TURN INSTALLATION. FLEXTILE GROUT COLOR "PLATINUM," GROUT WIDTH OF 1/16 ". GROUT MUST BE SEALED AFTER 5 DAY CURE. RESTROOM WALL TILE: MOHAWK GLAZED CERAMIC "CASTLEMERE" WALL TILE 5/16" 3" X 6" NOMINAL SIZE, COLOR "STAR WHITE ". TILE TRIM 5/16" 1" X 6" QUARTER ROUND TOP EDGING, COLOR "STAR WHITE ". TILE TO COVER WALL APPROX. 4' -7" OF WALL FROM FLOOR LEVEL. FLEXTILE GROUT COLOR "PLATINUM" JOINTS TO BE 1/16" WIDE. GROUT MUST BE SEALED AFTER 5 DAY CURE. SEE PATCH CEILING FROM OLD LIGHTING FIXTURE REMOVAL & AT WALL REMOVAL SITE INSTALL NEW SURFACE MOUNTED LIGHTING FIXTURE. SEE ELECTRICAL DRAWINGS. PREP CEILING FOR PAINT. STAINLESS STEEL NOMINAL 6 "x6" PLUMBING ACCESS DOOR. INSTALL WALL FINISHES BEFORE INSTALLING ACCESS DOOR. DO NOT PAINT ACCESS DOOR. BOTTOM OF DOOR OPENING TO BE AT +12" ABOVE FINISH FLOOR. STAINLESS STEEL NOMINAL 6 "x6" PLUMBING ACCESS DOOR. INSTALL WALL FINISHES BEFORE INSTALLING ACCESS DOOR. DO NOT PAINT ACCESS DOOR. BOTTOM OF DOOR OPENING TO BE AT +24" ABOVE FINISH FLOOR. NEW PLASTIC LAMINATE SURFACED COUNTERTOP AND 4" BACKSPLASH, WILSONART INTERNATIONAL #4674-60 "EVENING TIGRIS." EASE ALL EDGES. RECEIVED CITY OF TUKWILA OCT 2 5 2007 PERMIT CENTER CURRENT REVISION SYMBOL 141602 -0 SHEET REVISION MEZZ. H14 OFFICE RENOVATION J 11160621 -00 APPROVED 07.03.07 REVISION APPROVED Q�B /N '- ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN LMC CHECKED TWH ENGINEER CHECKED APPROVED APPROVED DATE 06.06.07 07.09.07 SUBTITLE ARCHITECTURAL MASTER MEZZ. H14 ENLARGED BUILDING 09 -101 JOB NO, M1A451 160621 -00 09 -101- M1A451 1A iez i " ' nlarge� I artial Plan ntirtra I n Ri li '"vnhann, • of 1NA Inr. Pnr i isanA C:nnrlitinns Artreemnnf see www hxwe ram DWG NO. n 0 N n 0 TABLE EMT DIA. MAX. LENGTH 3/4" 6'--0" 1" 8' -0" 1 1/2" 12' -0" 1" OR 1 1/2" EMT CONDUIT BRACING AT 8' -0" O.C. (MAX) ALTERNATE EACH WAY (NOTE: WALL INTERSECTION CAN COUNT AS BRACE) SCREW TO TOP TRACK WITH #10 x 1" SHEET METAL SCREWS --- �� FLATTEN EMT AT ENDS AND BEND ATTACH TO TOP TRACK WITH (1) #8 (MIN) SUSPENDED ACOUSTICAL CEILING SYSTEM DEMOUNTABLE PAR TOP CEILING TRAC INSTALL WITH (2) HILTI #X— DNI -22P8 PINS 7/8" 4 TITION WALL [76" K DEMOUNTABLE PARTITION WALL STUD EXTENSION DEMOUNTABLE PARTITION WALL METAL STUD (2 ") AT 2' -0" O.C. 2" INSULATION DEMOUNTABLE PARTITION WALL PANEL (VINYL FACED 5/8" GYPSUM WALLBOARD EACH SIDE OF WALL) DEMOUNTABLE PARTITION WALL - SECTION (TYP) DEMOUNTABLE PARTITION WALL FLOOR TRACK SECURED TO FLOOR DECK WITH POWDER DRIVEN HILTI #X— DNI -22P8 7/8" LONG © 4'—O" O.C. (MAX.) SCALE: NONE (2) 5/8 "x2' -0" VINYL FACED GYPSUM PANEL SPACER CHANNEL © 24" O.C. ATTACHMENT CLIP @ 18" O.C. 2" 'I' STUD ® 24" O.C. WITH FLOOR AND CEILING TRACK 2" INSULATION CEILING HIGH DEMOUNTABLE PARTITION 12 GA. HANGER WIRES (TYPICAL) E DETAIL LIGHT FIXTURE ATTACHED TO SUSFENDED CEILING SYSTEM WITH (2) 1/2" SELF TAPPING SMS, ONE AT EACH END C SERVICE TEAM OFFICES 4773220 -00 CONSTRUCT WORKROOM J #786032 -LO 9-101 M16 MEZZ OFFICE RENOVATION J#160620-00 9 -101 H14 MEZZ OFFICE RENOVATION 4160621 -00 TWH GMM LMC LMC TWH 10.01.97 12.11.98 05.02.07 07.03.07 SYM REVISION BY APPROVED DATE SYM D REVISION BY APPROVED DATE Ii /NC ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN CHECKED LATE SUBTITLE MEZZ. MISC. DETAILS 8c SECTIONS APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER BUILDING 09 -101 MEZZ. PLANS DEV. CENTER, WA CURRENT REVISION J#160621-00 SYMBOL 7 SHEET VA5O1 JOB NO 160621 -00 DATE 07.03.07 9 COMP NO. DWG NO. 9-101— M1A501 w r z W U 0 S 45 45' CEILI SCALE: NONE W CROSS TEE 45' NOTE: HANGER WIRES "E" AND "W" ARE IN THE SAME VERTICAL PLANE AS THE MAIN TEE. HANGER WIRES "N" AND "S" ARE IN VERTICAL PLANES PERPENDICULAR TO THE MAIN TEE. CEILI ' SCALE: NONE 2" WIDE x2 "LONG x 12 GA. STRAP 2" WIDE x 2" LONG x 12 GA. STRAP HA SCALE: 3 " =1 —0" 0 0 0 0 0 0 G LAYOUT - G BRACE - DETAIL (TYP) 0 12' -0" ON CENTER 0 \GER WIRE - SECTIO DETAIL (TYP) MAIN TEE 12 GA. VERTICAL HANGER WIRE SEE DETAIL USE #12 GA. SPLAY WIRE BRACING IN PLANE OF EACH TEE. VERTICAL ANGLE, 45 *. MINIMUM 3 TIGHT TURNS AT EACH END. NO BENDS OR KINKS ON WIRES. E 1/4" DIAMETER x 1" LONG SELF TAPPING SCREW WITH WASHER 12 GA. HANGER, SLACK AND /OR SPLAY WIRE, TYP 3 FULL TURNS EACH END 1/4" DIAMETER x 1" LONG SELF TAPPING SCREW WITH WASHER 12 GA. SLACK AND /OR SPLAY WIRE, TYP 3 FULL TURNS EACH END V (TYP) #12 WIRE PERIMETER HANGERS, 8" MAX FROM WALLS SEE DETAIL #12 WIRE HANGERS AT 4' -0" 0.0. EACHWAY SUSPENDED FROM STRUCTURE ABOVE. CEILING BRACING AT 12'- -0 "x12' -0" O.C. (MAX) TO MATCH STRUCTURAL SYSTEM AND ON CENTER. EACH WAY. SEE DETAIL LOCATE FIRST POINT OF BRACING WITHIN 4' —O" OF WALLS. (OMIT WHERE ROOM IS 128 SQUARE FEET OR LESS) A501 A502 A501 A501 (5 A501 8" MAX. 3/4" MIN. PROVIDE CLEARANCE AT OPPOSITE WALLS, (NOT ATTACHED). ATTACHED AT STARTING AND ONE ADJACENT WALL CEILING GRID AT WALL - SECTIO\ SCALE: NONE #12 GA. HANGER WIRE, TYP. 3 TURNS, MINIMUM 8" MAX. 21 MIN. (TYP) (Th M1A501 SUSPE \DED SUSPENDED CEILINGS ARE TO COMPLY WITH THE FOLLOWING CODES AND REGULATIONS: A. 2003 INTERNATIONAL BUILDING CODE (IBC) SECTIONS 803.9 AND 1621.1 B. ASTM C635 AND ASTM C636 (REFERENCED IN IBC 803.9). ASTM — AMERICAN SOCIETY FOR TESTING AND MATERIALS. C. ASCE -7 SECTION 9.6.2.6 (REFERENCED IN IBC 1621.1.2). ASCE -- AMERICAN SOCIETY OF CIVIL ENGINEERS. D. CISCA RECOMMENDATIONS FOR SEISMIC ZONES 3 -4 (REFERENCED IN ASCE-7 SECTION 9.6.2.6.2.2). CISCA — CEILINGS & INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION. E. IBC 102.1 STATES, "WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE APPLICABLE." F. PARTIAL LISTING OF REQUIREMENTS FOR SUSPENDED CEILINGS: a. ONLY A HEAVY DUTY DONN DXL SERIES T ---BAR GRID SYSTEM SHALL BE USED. ASCE-7 SECTION 9.6.2.6.2.2 ITEM a. b. WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE (WALL ANGLE) SHALL BE NOT LESS THAN 2 ". ASCE -7 SECTION 9.6.2.6.2.2 ITEM b. c. ON TWO ADJACENT SIDES, THE GRID SHALL BE ATTACHED TO THE WALL ANGLE. POP RIVETS ARE ACCEPTABLE. ON THE OTHER TWO SIDES, THERE SHALL BE A 3/4" CLEARANCE BETWEEN THE ENDS OF THE GRID AND THE WALL. • ASCE -7 SECTION 9.6.2.6.2.2 ITEM b. d. ON THE OTHER TWO SIDES, THERE SHALL BE 3/4" CLEARANCE BETWEEN THE ENDS OF THE GRID AND THE WALL. ASCE -7 SECTION 9.6.2.6.2.2 ITEM b. e. STABILIZER BARS ARE REQUIRED TO PREVENT THE SPREAD OF MAIN BEAMS AND /OR CROSS TEES. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 &4, MAY, 2004, INSTALLATION SECTION, ITEM 4. f. PERIMETER SUPPORT (TAIL) WIRES ARE REQUIRED WITHIN 8" OF THE WALL FOR ALL EDGES. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY, 2004, INSTALLATION SECTION, ITEM 2. VERTICAL HANGERS SHALL BE NP. 12 GAGE WIRE SPACED © 4' -0" ON CENTER OR NO. 10 GAGE SPACED © 5'--0" ON CENTER ALONG EACH MAIN RUNNER. THREE WIRE TURNS REQUIRED. WITHIN 1:6 OUT—OF—PLUMB UNLESS COUNTER — SLOPING WIRES ARE PROVIDED. h. LATERAL BRACING IS REQUIRED: SPLAY WIRE PODS @ 12' -0" MAX. ON CENTER AND 6' —O" MAX. FROM WALLS. INSTALL TRULY COMPRESSIBLE (e.g. SPRING LOADED) STRUTS OR NO STRUTS AT ALL. RIGID STRUTS ARE NOT ALLOWED. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY, 2004, INSTALLATION SECTION, ITEM 3, AND CITY OF KENT POLICY. i. CEILINGS OVER 2,500 SQ. F. MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2,500 SQ. FT. ASCE -7 SECTION 9.6.2.6.2.2 ITEM d. k. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. ASCE -7 SECTION 9.6.2.6.2.2 ITEM f. I. SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVER —SIZE RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS, OR A SWING JOINT THAT CAN ACCOMODATE 1" OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IF INSTALLED AT THE TOP OF THE SPRINKLER HEAD EXTENSION. ASCE -2 SECTION 9.6.2.6.2.2 ITEM e. g. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. ASCE -7 SECTION 9.6.2.6.2.2 ITEM g. CEILI GS OTES RECEIVED CITY OF TUKWILA OCT 2 5 2007 PERMIT CENTER N SYM SUSPENDED CEILING MICROWAVE SHELF W /LAMINATE -�- - EDGE. SOAP DISPENSER 4" BACKSPLASH U.G. MOUNTED 10" X 14" X 5" STAINLESS STEEL SINK. (SEE MECH DRAWINGS.) SOLID RESIN COUNTER TOP & INTEGRAL BACKSPLASH WITH EASED EDGE STAINLESS STEEL 3" DRAWER PULL (TYP) BLOCKING AS REQUIRED TYP. DOOR PULL 1A503 I'itchenette FI„, & Sections DRAWERS W/ LAMINATE FACES & TOP EDGE (SEE NOTE BELOW FOR COLOR SPECS) BASE CASEWORK INWILSONAR INTERNATIONAL PLAM COLOR #13007-60 "BRUNE CROSSWEAVE" MATTE FINISH ROPPE RESILIENT BASE COLOR "FAWN" #P140 <ircHE SCALE: 1 1/2"= 1' -0" REVISION WALL MOUNTED CASEWORK IN - WILSONART INTERNATIONAL PLAM COLOR #13007 -60 "BRUNE CROSSWEAVE" MATTE FINISH LAMINATE EDGED ETTE CASEWOR ntAdorl a. ra -�'c2r cli}10 SO haCCv]K'!t cso un.v.0 {_`SLAL'] m BY < SECTIO APPROVED 4' -4 7/8" ± R.O. DATE SYM I � 1 M1A503 2 ' -O " -0" REVISION • • • • • • • KITCHEN ETTE CASEWOR SCALE: 1 1/2 "= 1 -0 BY APPROVED DATE 4'-4 7/8" ± R.O. CD � SECTIOk • • • • • • • • -0" g • • • • • • • • • • • A 9 -101 H14 MEZZ OFFICE RENOVATION 4160621 -00 LMC 07.03.07 WALL MOUNTED CASEWORK IN WILSONART INTERNATIONAL PLAM COLOR #13007-60 "BRUNE CROSSWEAVE" MATTE FINISH LAMINATE FACED SPACER STRIP. POWER OUTLET. COLOR - "OFF- WHITE." SEE ELECTRICAL DRAWINGS. STAINLESS STEEL 10" X 14" X 5" STAINLESS STEEL SINK & FAUCET FIXTURE. (SEE MECH. DRAWINGS) SOLID RESIN COUNTER TOP & INTEGRAL BACKSPLASH WITH EASED EDGE. MANUFACTURER: LG HIMACS, COLOR #G48 "BEACH SAND." 1 SPACER STRIP DRAWERS BASE CASEWORK IN FORMICA COLOR WILSONART INTERNATIONAL PLAM COLOR #13007-60 "BRUNE CROSSWEAVE" MATTE FINISH. I ° 1 M1A503 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY f DEPT. DATE DRAWN LMC CHECKED TWH ENGINEER CHECKED APPROVED APPROVED M1A503 <ITCHENETTE CASEWOR SCALE: 1 1/2 "= 1 -0" I?ATE 06.06.07 07.09.07 TITLE 5'-4 3/8" ± R.O. � ELEVATIO M1A503 SUBTITLE MEZZ. KITCHENETTE ELEVATION & SECTIONS M1A455 B BUILDING 09 -101 ARCHITECTURAL MASTER MEZZ. PLANS DEV. CENTER, WA 8" 8 M1A503 CURRENT REVISION � # 160621 -00 SHEET JOB NO. DWG NO. SHELF FOR MICRWAVE WITH -------- ADJUSTABLE SHELVES v LAMINATE EDGE. STAINLESS STEEL WIRE 3" DOOR PULL (TYP) LAMINATE FACED SPACER STRIP. WALL MOUNTED CASEWORK IN WILSONART INTERNATIONAL PLAM COLOR #13007 -60 "BRUNE CROSSWEAVE" INTEGRAL SOLID SURFACE /RESIN EASED EDGE BACKSPLASH SPACER STRIP STAINLESS STEEL 3" WIRE DOOR PULL (TYP) _ RESILIENT BASE, ROPPE COLOR #P140 "FAWN" BOEING PROVIDED 1A503 160621 -00 SYMBOL A DATE 9- 101- M1A502 RECEIVED CITY OF TUKWILA OCT 2 5 2007 PERMIT CENTER COMP NO. 07.03.07 1 FT81 4C: 07/12/07 1' -8 1/4" 1 3 „a - ,Z 1' -10 1/8" r r 3/ 1/4" C -8 ,- > � �l , 1' -8 1 /4" \ 7 ■ 1' -8 1/4" I „9 1 -8 M 1/4" 7 SYM SUSPENDED CEILING MICROWAVE SHELF W /LAMINATE -�- - EDGE. SOAP DISPENSER 4" BACKSPLASH U.G. MOUNTED 10" X 14" X 5" STAINLESS STEEL SINK. (SEE MECH DRAWINGS.) SOLID RESIN COUNTER TOP & INTEGRAL BACKSPLASH WITH EASED EDGE STAINLESS STEEL 3" DRAWER PULL (TYP) BLOCKING AS REQUIRED TYP. DOOR PULL 1A503 I'itchenette FI„, & Sections DRAWERS W/ LAMINATE FACES & TOP EDGE (SEE NOTE BELOW FOR COLOR SPECS) BASE CASEWORK INWILSONAR INTERNATIONAL PLAM COLOR #13007-60 "BRUNE CROSSWEAVE" MATTE FINISH ROPPE RESILIENT BASE COLOR "FAWN" #P140 <ircHE SCALE: 1 1/2"= 1' -0" REVISION WALL MOUNTED CASEWORK IN - WILSONART INTERNATIONAL PLAM COLOR #13007 -60 "BRUNE CROSSWEAVE" MATTE FINISH LAMINATE EDGED ETTE CASEWOR ntAdorl a. ra -�'c2r cli}10 SO haCCv]K'!t cso un.v.0 {_`SLAL'] m BY < SECTIO APPROVED 4' -4 7/8" ± R.O. DATE SYM I � 1 M1A503 2 ' -O " -0" REVISION • • • • • • • KITCHEN ETTE CASEWOR SCALE: 1 1/2 "= 1 -0 BY APPROVED DATE 4'-4 7/8" ± R.O. CD � SECTIOk • • • • • • • • -0" g • • • • • • • • • • • A 9 -101 H14 MEZZ OFFICE RENOVATION 4160621 -00 LMC 07.03.07 WALL MOUNTED CASEWORK IN WILSONART INTERNATIONAL PLAM COLOR #13007-60 "BRUNE CROSSWEAVE" MATTE FINISH LAMINATE FACED SPACER STRIP. POWER OUTLET. COLOR - "OFF- WHITE." SEE ELECTRICAL DRAWINGS. STAINLESS STEEL 10" X 14" X 5" STAINLESS STEEL SINK & FAUCET FIXTURE. (SEE MECH. DRAWINGS) SOLID RESIN COUNTER TOP & INTEGRAL BACKSPLASH WITH EASED EDGE. MANUFACTURER: LG HIMACS, COLOR #G48 "BEACH SAND." 1 SPACER STRIP DRAWERS BASE CASEWORK IN FORMICA COLOR WILSONART INTERNATIONAL PLAM COLOR #13007-60 "BRUNE CROSSWEAVE" MATTE FINISH. I ° 1 M1A503 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY f DEPT. DATE DRAWN LMC CHECKED TWH ENGINEER CHECKED APPROVED APPROVED M1A503 <ITCHENETTE CASEWOR SCALE: 1 1/2 "= 1 -0" I?ATE 06.06.07 07.09.07 TITLE 5'-4 3/8" ± R.O. � ELEVATIO M1A503 SUBTITLE MEZZ. KITCHENETTE ELEVATION & SECTIONS M1A455 B BUILDING 09 -101 ARCHITECTURAL MASTER MEZZ. PLANS DEV. CENTER, WA 8" 8 M1A503 CURRENT REVISION � # 160621 -00 SHEET JOB NO. DWG NO. SHELF FOR MICRWAVE WITH -------- ADJUSTABLE SHELVES v LAMINATE EDGE. STAINLESS STEEL WIRE 3" DOOR PULL (TYP) LAMINATE FACED SPACER STRIP. WALL MOUNTED CASEWORK IN WILSONART INTERNATIONAL PLAM COLOR #13007 -60 "BRUNE CROSSWEAVE" INTEGRAL SOLID SURFACE /RESIN EASED EDGE BACKSPLASH SPACER STRIP STAINLESS STEEL 3" WIRE DOOR PULL (TYP) _ RESILIENT BASE, ROPPE COLOR #P140 "FAWN" BOEING PROVIDED 1A503 160621 -00 SYMBOL A DATE 9- 101- M1A502 RECEIVED CITY OF TUKWILA OCT 2 5 2007 PERMIT CENTER COMP NO. 07.03.07 1 FT81 4C: 07/12/07 HARDWARE SCHEDULE DOOR HARDWARE GROUPS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 HEIGHT SWING DOOR NUMBERS M13H14 M14H14 M12613 M15H14 M11G13 M12H13 M11H13 M13H14 M1A450 H14 OFFICE 3' -O" T -0" EXISTING - -- 1 FL ....... M11H14 5 1/8" .. -- M11G13 M1A450 H14 OFFICE 3' -O" T -0" EXISTING --- 1 M12H14 RHRB HIn1 4 5/8" --- -- r # OF HARDWARE GROUPS 2 4 2 1 0 0 0 0 0 0 0 0 0 0 9 1 HARDWARE ITEMS # OF ITEMS REQ'D FOR EACH HARDWARE GROUP - -- 2 # OF ITEMS TO BE SUPPLIED 1 HINGES: STANLEY FBB179 4- 1/2x4 -1/2 NRP US26D 3 1/4" 3 3 6 M12H14 M1A450 OFFICE 3' -0" 7' -0" NEW --- 2 F 24 2 HINGES: STANLEY FBB179 5" X 4 -1/2" US26D (FOR 4' WIDE DOOR) --- -- 6 M11H14 M1A450 CONFERENCE 3' -O" 7-0" NEW -- 2 F LH 0 3 HINGES: BY DOOR FABRICATOR 1/A351 9 M12H14 M1A450 CONFERENCE 3' -O" 7' -0" NEW --- 2 F RH HI'11 5 1/8" 4 KICKPLATE: QUA 48 SERIES 10 "x34" STAINLESS 6 2 4 8 5 KICKPLATE: QUA 48 SERIES 10 "x46" STAINLESS M12G13 M1A450 MEN'S BATHROOM 3' -0" 7' -D" NEW -- 3 F LH HIl1 5 1/8" - -- 0 6 CLOSER: NORTON 7500BF US26D M11H13 M1A450 1 3' -0" 7' -0" NEW -- 3 F LH HI/I1 4 5/8" -- --- 2 7 CLOSER: LCN 4040 SUPER SMOOTHIE W /AUX STOP 120 DEG. HOLD OPEN ARM 0 8 LOCKSET, LEVER: PASSAGE FUNCTION YALE AU5401xUS26D LOADING DOOR 6-0" 7' -O" EXISTING --- 4 FP LH/RH HVI1 5 1/8" --- — 8 0 9 LOCKSET, LEVER: OFFICE FUNCTION YALE AU5407xUS26D 1 1 5 10 LOCKSET, UNICAN: LL- 1021 -M -26D (KEY OVERRIDE) FACTORY HANDED UNICAN, 3/4" LATCH BOLT GENERAL NOTES: j J 0 LOCKSET, UNICAN: LR- 1021 -M -26D (KEY OVERRIDE) FACTORY HANDED UNICAN, 3/4" LATCH BOLT I A. BOEING TO PROVIDE 1" HIGH DOOR NUMBER SIGN FOR SHOP PRIMED. DOOR NUMBER EVERY DOOR LISTED IN SCHEDULE. MOUNT W /DBL STICK TAPE CENTERED ON EXTERIOR FRAME HEAD. B. ALL SWING DOORS TO BE FACTORY J I I 0 12 LOCKSET, UNICAN: LRP- 1020 -M -26D (MATES TO VON DUPRIN 99E0 EXIT DEVICE) UNICAN, 3/4" LATCH BOLT C. ALL H.M. FRAMES AND DOORS TO HAVE STAMPED IN TOP HINGE CUT -OUT. 0 13 LOCKSET, UNICAN: LLP- 1020 -M -26D (MATES TO VON DUPRIN 99E0 EXIT DEVICE) UNICAN, 3/4" LATCH BOLT I l 0 14 SMOKE SEALS: PEMKO S88D17 1 1 1 F FLUSH SOLID WOOD, BIRCH VENEERED SWING DOOR, SAND, SWING DOOR WITH SWING DOORS, SEAL & CLEAR COAT. 8" X 32" (256 SQ. IN.) WINDOW SAND, SEAL & CLEAR 8 15 SMOKE SEALS: PEMKO S88D20 1 FL FLUSH SOLID WOOD, BIRCH VENEERED COAT. LIGHT 1 17 FLUSH BOLT: IVES #458 US26D EXTENSION TYPE (FOR INACTIVE LEAF) 0 18 PANIC E)IT DEVICE & LEVER LATCHSET: 99 L US26D (LHRB /RHRB) 36. SEE DOOR SCHEDULE FOR SWING 1 DOOR FRAME CONSTRUCTION 1 I 2 29 VISION LIGHT: 8 "x 32" HM FRAME W /WIRE OR FIRE LAMINATED GLASS HM1 HOLLOW METAL GRADE 2, 16 GA _ _ SHOP PRIMED, BRUSHED ALUMINUM FINISH. HM2 0 20 SECURITY EXIT DEVICE SYSTEM - RHR AC11VE, 36" DOOR, W/ #9 (8497 -004) DEADBOLT STRIKE & #499 VON DUPRIN PANIC BAR OPTIONAL ST1KE FOR DBL DRS SND1 KRIEGER ACOUSTICAL DOOR /FRAME LIFT HINGES, THRESHOLD AND ASSEMBLY RATING LABEL REQ'D. PROVIDE DOOR ASSEMBLY WITH CAM - DOOR. ASSEMBLY TO BE SET ON EPDXY OR VCT FLOOR, NO SND2 KRIEGER ACOUSTICAL DOOR /FRAME /HARDWARE, STC 49, MODEL NC7 -16 -8649, PROVIDE DOOR ASSEMBLY WITH CAM -LIFT HINGES, THRESHOLD AND 3 EACH "Z' HARDWARE MOUNTING BRACKETS PER DOOR. ASSEMBLY TO BE SET ON EPDXY OR VCT FLOOR, NO CARPET AT EITHER SIDE. SHIP THIS U 0 21 S &G 8470 -050 (MANUAL) HIGH SECURITY EAT DEVICE SYSTEM ,• RHR SWING, 48" DOOR EM COMMENTS 0 22 S &G 8470 -050 (MANUAL) HIGH SECURITY EXIT DEVICE SYSTEM - LHR SWING, 48" DOOR 1 ORDER INACTIVE LEAF W/ ASTRAGAL 2 0 23 FLOOR STOP: IVES 442B26D)MS US26D ._ 3 RHR ACTIVE r 0 24 WALL BUMPER: TRIMCO 1271SA GREY, SELF ADHESIVE, 1* 1 ** 1 .1;„..4 5 '7 25 OVERHEAD STOP: DORMA #902 -S 36" DOOR, SURFACE MTD STOP, AL FINISH - — — __ ___.__ _ 7 THRESHOLD BY DOOR MANUFACTURER 0 26 OVERHEAD STOP: DORMA #903 -S 48" DOOR, SURFACE MTD STOP, AL FINISH 8 LH ACTIVE f I 0 27 PEMKO 4131CPKL AUTOMATIC DOOR BOTTOM, CLEAR ANODIZED, NON - HANDED, 9 /16IN DEEP X 1 -7 /8IN HIGH X [36] INCH DOOR WIDTH, SURFACE MOUNT 1 1 1 2 10 28 IVES 8200B26D US26D 4 "x16" PUSH PLATE 1 2 29 IVES 8311 -5B26D US26D 4 "x16" PULL PLATE 1 2 * = WALL BUMPER FOR DOOR M13H14 ONLY. . * *= WALL BUMPER FOR DOORS M11H14, M14H14 & M12H13 ONLY. * * *= WALL BUMBER FOR (LH AC11VE LEAF) ONLY. IYOR SCHEDULE DOOR DWG # ROOM FUCTION OPENING (NOM.) DR/FRAME STATUS ASSEMBLY RATING HRDW GROUP DOOR TYPE DOOR FRAME THROAT DETAILS # WIDTH HEIGHT SWING CONSTR.DIM. (IN.) HEAD JAMB COM MENTS M13H14 M1A450 H14 OFFICE 3' -O" T -0" EXISTING - -- 1 FL RHRB Hf'11 5 1/8" --- -- M11G13 M1A450 H14 OFFICE 3' -O" T -0" EXISTING --- 1 FL RHRB HIn1 4 5/8" --- -- M14H14 M1A450 PRIVACY /MEETING 3' -O" 7' -0" NEW - -- 2 F LH Hf/I2 3 1/4" -- 1/A351 9 M12H14 M1A450 OFFICE 3' -0" 7' -0" NEW --- 2 F LH HIM 5 1/8" --- -- 6 M11H14 M1A450 CONFERENCE 3' -O" 7-0" NEW -- 2 F LH HI/I2 3 1/4" - -- 1/A351 9 M12H14 M1A450 CONFERENCE 3' -O" 7' -0" NEW --- 2 F RH HI'11 5 1/8" -- --- 6 M12G13 M1A450 MEN'S BATHROOM 3' -0" 7' -D" NEW -- 3 F LH HIl1 5 1/8" - -- -- 6 M11H13 M1A450 WOMEN'S BATHROOIV 3' -0" 7' -0" NEW -- 3 F LH HI/I1 4 5/8" -- --- 6 M15H14 M1A450 LOADING DOOR 6-0" 7' -O" EXISTING --- 4 FP LH/RH HVI1 5 1/8" --- — 8 GENERAL NOTES: j J I A. BOEING TO PROVIDE 1" HIGH DOOR NUMBER SIGN FOR SHOP PRIMED. DOOR NUMBER EVERY DOOR LISTED IN SCHEDULE. MOUNT W /DBL STICK TAPE CENTERED ON EXTERIOR FRAME HEAD. B. ALL SWING DOORS TO BE FACTORY J I I C. ALL H.M. FRAMES AND DOORS TO HAVE STAMPED IN TOP HINGE CUT -OUT. I l DOOR TYPES F FLUSH SOLID WOOD, BIRCH VENEERED SWING DOOR, SAND, SWING DOOR WITH SWING DOORS, SEAL & CLEAR COAT. 8" X 32" (256 SQ. IN.) WINDOW SAND, SEAL & CLEAR FL FLUSH SOLID WOOD, BIRCH VENEERED COAT. LIGHT _ — FP PAIR OF FLUSH SOLID WOOD, BIRCH VENEERED DOOR FRAME CONSTRUCTION 1 I HM1 HOLLOW METAL GRADE 2, 16 GA _ _ SHOP PRIMED, BRUSHED ALUMINUM FINISH. HM2 HOLLOW METAL DEMOUNTABLE GRADE 2, 16 GA SHOP PRIMED, BRUSHED ALUMINUM /HARDWARE, STC 49, MODEL NC7 -16 -8649, 1 HOUR 3 EACH "Z' HARDWARE MOUNTING BRACKETS PER FINISH. SND1 KRIEGER ACOUSTICAL DOOR /FRAME LIFT HINGES, THRESHOLD AND ASSEMBLY RATING LABEL REQ'D. PROVIDE DOOR ASSEMBLY WITH CAM - DOOR. ASSEMBLY TO BE SET ON EPDXY OR VCT FLOOR, NO SND2 KRIEGER ACOUSTICAL DOOR /FRAME /HARDWARE, STC 49, MODEL NC7 -16 -8649, PROVIDE DOOR ASSEMBLY WITH CAM -LIFT HINGES, THRESHOLD AND 3 EACH "Z' HARDWARE MOUNTING BRACKETS PER DOOR. ASSEMBLY TO BE SET ON EPDXY OR VCT FLOOR, NO CARPET AT EITHER SIDE. SHIP THIS U EM COMMENTS 1 ORDER INACTIVE LEAF W/ ASTRAGAL 2 PREP INACTIVE LEAF FOR FLUSH BOLTS & STRIKE ._ 3 RHR ACTIVE r 4 LHR ACTIVE I 5 __ DO NOT MOUNT ANY HARDWARE ON FRAME ATTACHED SOUND SEALS. USE MANFUFACTURER'S SUPPLIED "Z' CLIP TO MOUNT ALL STRIKES OR CLOSER ARMS. 6 DOOR SUPPLIED BY DAVIS DOOR CO. - — — __ ___.__ _ 7 THRESHOLD BY DOOR MANUFACTURER 8 LH ACTIVE f I Y N \ . \ r \ r \ r r / \ r \ / \ r \ r r IIM 1A351 nvirl. -..J SYM A C DOOR TYPES F (FLUSH DOOR *) KICK PLATE FP @ EA. SIDE (PAIR FLUSH DOORS *) * SOLID CORE WOOD REVISION Me71. In; '; for Ele■dolinns ? Secticn �y,�,- ry„9l,..l,•..: -..-., .,- ,.y.•,. -:.. ,_4_ ,'_L ., „ - �,•.s�r-.� -��;�- rte. °r, ;s-�: Y.ti;'r= -wn :5 �. ^� /ra; : 'n, BY APPROVED DATE SYM REVISION BY APPROVED DATE 3 1/4" (2) 5/8 "x2' --0" VINYL FACED GYPSUM WALLBOARD PANEL (2) 2 "x20 GA. METAL STUD HOLLOW METAL DOOR FRAME 1 3/4" SOLID WOOD DOOR JAV DE V B DETAIL AT our SCALE: NONE BOE /NG (-- 2" THEREMAFIBER INSTUALTION 2 5/8" 2 " 1/2" 5/8" TABLE PARTITIO 2 3/8" HEAD 4 1/4" Sly 9 -101 H14 MEZZ. OFFICE RENOVATION 4160621 -00 LMC 07.03.07 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY ILAR) w� DEPT. DATE DRAWN GMM CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 05.26.94 SUBTITLE TITLE ARCHITECTURAL MASTER i BUILDIk 6 D MEZZ. INTERIOR ELEVATIONS & SECTIONS G 09-101 MEZZ. PLANS DEV. CENTER, WA GENERAL NOTES: 1. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS BEFORE ORDERING MATERIAL AND COMMENCING WORK. 2. COORDINATE WORK WITH ALL REQUIRED TRADES. 3. REMOVE ALL DEMOLITION MATERIAL FROM BOEING PROPERTY UNLESS OTHERWISE NOTED. 4. LEAVE WORK AREA CLEAN AND UNCLUTTERED AT THE END OF EACH DAY. 5. REMOVE ALL CONSTRUCTION MATERIALS AND CLEAN ALL WORK AREAS AT THE COMPLETION OF THE PROJECT. 6. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITHOUT WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE FOR THAT PORTION OF THE WORK. THE GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS. IF ANY DISCREPANCIES EXIST BETWEEN THE PROPOSED AND EXISTING CONDITIONS OTHER THAN THAT INDICATED ON THE DRAWINGS, THE GENERAL CONTRACTOR SHALL NOT PROCEED WITH THAT WORK UNTIL A CORRECTIVE PROCEDURE HAS BEEN IDENTIFIED AND APPROVED BY THE BOEING CONSTRUCTION MANAGER. 7. DOOR OPENINGS ARE 6" FROM ADJACENT WALL, UNLESS DIMENSIONED OTHERWISE. 8. DOOR MARKS ARE ASSIGNED RELATIVE TO THE MAJOR BUILDING —GRID BAY IN WHICH THE ELEMENT OCCURS. THE DOOR MARK IS COMPOSED AS FOLLOWS: 12N16 FLOOR NUMBER �`�GRID NUMBER SEQUENCE NUMBERS GRID LETTER 9. DOOR FRAMES HUNG WITH LABELED DOORS SHALL ALSO BE LABELED WITH THE SAME RATING. 10. DOOR /ROOM NUMBERS TO BE PROVIDED BY BOEING. INSTALL NUMBER SIGNAGE CENTERED ON DOOR FRAME ON BOTH SIDES OF DOOR & AT ALL DOOR LOCATIONS. 11. ROOMS ARE GIVEN THE SAME MARK AS THE DOOR INTO THE ROOM; FOR ROOMS WITH SEVERAL DOORS, THE LOWEST NUMBERED DOOR MARK IS USED. 12. OPENING FORCE OF DOORS WITHIN AN ACCESSIBLE ROUTE OF TRAVEL SHALL NOT EXCEED 5 POUNDS AT INTERIOR DOORS. ALL INTERIOR DOORS SHALL HAVE LEVER HANDLES WHICH PERMIT OPERATION BY WRIST OR ARM PRESSURE. 13. DOORS: 3'—O" X 7' -0" X 1 3/4" SOLID CORE, STAIN GRADE BIRCH, SEAL TOP AND BOTTOM EDGES, CLEAR VARNISH. PREPED FOR BORED CYLINDRICAL LOACKSET AND (3) 4 1/2" X 4 1/2" HINGES. SHOP PRIMED. 14. DOOR FRAME: DOOR FRAME SHALL BE AS SCHEDULED. SPECS BELOW: 16 GA KNOCK DOWN, SPECIFIED THROAT (SEE SCHEDULE), WELD "7" ANCHORS TO FRAME. PREPED FOR BORED CYLINDRICAL LOACKSET AS SCHEDULED AND (3) 4 1/2" X 4 1/2" HINGES. DOOR NUMBER INSIDE TOP HINGE CUT OUT. ALL DOOR FRAMES IN BRUSHED ALUMINUM FINISH UNLESS OTHERWISE NOTED. CURRENT REVISION 4160621-00 SHEET JOB NO DWG NO. SYMBOL V1A351 160621 -00 DATE 9- 101— M1A351 RECEIVED CITY OF TUKWILA OCT 2 5 2007 PERMIT CENTER COMP NO. 07.03.07 11 FT814-C: 07/11/07 16:23 1M455 REVISION 1 "CW DN TO FIXTURES 4 "WDN &4 "V UP wriirew. APPROVED 06/27/07 REVISION \IEZZA SCALE: 1/4" APPROVED PLUVBI APPROVED BY ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DRAWN S.RUDELL CHECKED ENGINEER CHECKED APPROVED APPROVED • • • u. DATE 06.11.07 SUBTITLE GENERAL f� PLUMBING MATERIALS: TYPE L COPPER PIPE, ASTM B88; SWEAT SOLDER OR RIDGID PROPRESS FITTINGS & JOINTS; INSULATE WITH PREFORMED ELASTOMERIC PIPE INSULATION, ASTM C 534 TYPE 1, 1" THICK FOR HW, 1/2" THICK FOR CW. PLUMBING - MEZZANINE PLAN 109-101-4175 M6 CO STRUCTIO REMOVE AND REPLACE PLUMBING TO SUPPORT RESTROOM REMODEL AS DEFINED ON ARCHITECTURAL DRAWINGS. CURRENT REVISION 16062100 JOB NO. KEY PLAN I ljj ' '11 11 OCT 2 5 2007 ill I PERMIT CENTER SYMBOL A COMP NO. zz ■`COVED CITY OF TUKWILA A REFURBISH MEZZANINE OFFICE 16062100 HARR PIIJI binq Me7: Plan - n.:i. IAIA I.. n RWS TITLE MECHANICAL MASTER BULDI\C 9-1C1.V COL, G- J/13 -15 D.0 DWG NO. 9-101-0 M455 A REMOVALS - OFFICE REFURB REVISION 16062100 APPROVED 06/18/07 REVISION vEZZA\INE HVAC PLA SCALE: 1/4" = 1 -0" APPROVED ,i BOE /NG° — AIR HANDLING UNIT TRANE #12-A-7000 CFM 2i S.P., 5 HP, 480V 30 APPROVED BY GREENHECK BCF 108 3HP 115/1 CFM — 1v -- - ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DRAWN S.RUDELL CHECKED ENGINEER - CHECKED APPROVED APPROVED DATE 06.11.07 REMOVAL SUBTITLE HVAC - MEZZANINE PLAN 14 "0 500 CFM (TYP) CFM 0 SDF F- ,-- r - r - --r _ REFERE 109 -101 -4564 M2 CE DRAWI RELOCATE 9 SUPPLY DIFFUSERS AS SHOWN. REMOVE ANY CUSTOM "MODIFICATIONS" ON EXISTING DIFFUSERS OR REPLACE WITH NEW MATCHING DIFFUSERS IF NOT REUSABLE. DISCONNECT THREE VAV BOXES AND ADJACENT DUCTWORK FOR RELOCATION AND REUSE PER 1M456 CLEAN AND INSPECT AIR HANDLING UNIT AND ALL ASSOCIATED DUCTWORK. CLEAN TRANE VCBC CONTROL BOXES. VERIFY TOILET EXHAUST FAN CONDITION AND PERFORMANCE. xps 8X8 S (TYP. 315 C 12X 12 CENTREX EXHAUST FAN 650 CFM 0 .375" S.P. HP, 120 V 10"0 SPIRAL DUCT 111 /I I > 20 F 111 a -- v° im m/20 _ • '00 CF X9 RD' 8 SDF P. 4) 280 WOM 12X .DF , III 1.�1 1 G 110 CFM ® 6X6 SDF a • U 255 CFM . �� V 1' 8 ' 0 `.' a 9X9 SDF /I —�• Ilr ��� 7 4 �� �� ��/ •••.— — EN —ogim���—� omit . 9 20 , '1 38 • 255 C �� 9X9 SD , 8 "� VD I, Q � ._�■■sn►r:■■�■■► IUN �� ■�+i+ww•.wr� . 430 CF 1 42 �� � 12X12 �, 'i _ RDF 6 / � � 430 • 1 ... . ,,,,,,„„ i 6,8,.„„,,,, !" .'! �i7�- — �� w�■ _ � ■, rIw'JI,J9-!- 9X9 SDF • � '._ � � CFM � . ��CFM -����� - �� - SDF SDF Vl} :, 44 bliiimillill 1 8' o ► "'�■.•- 77, .,.„../ ., Ill Mil 1 I iiiiiiiiiiiiiiii iL .___ iII ©�1 r 4/7 ita +w,�r f r_I� hl 8 » � 1 OA PA Et =7ww�wimakr I �Iw wwww■ I l,mwww►� swwwwrrs ww�w==■ g w�ww w►�r�wrr wnwww•�■w�w����� /III 11111111 55/14 CURRENT REVISION 16062100 RETURN DIFFUSER (RDF) DIFFUSER TO BE RELOCATED 16062100 SYMBOL A COMP NO. Zz hEG/ED CITY OF TUKWILA OCT 2 5 2007 PERMIT CENTER DATE 06/18/07 I M4r.,:; Ii' -Mr., i Ilan r..drlr.ri ., R. Hrinrc. C..rH,nnnc, n( tf Inr Fnr . iaana f nnrlifinn: Anraamanf can teiuner hvwa rnm TITLE MECHANICAL MASTER BUILDI\ I3 S -101.N COL. G- J/13 --15 D.C. DWG NO. 9-101-M1M456R T T TT T T T M'1M456 1 I • !EMI IM4F SYM A REMOVALS -- OFFICE REFURB B OFFICE REFURBISHMENT REVISION 16062100 16062100 ■ i11�1 ■� i�1 mi _ :.� ■ ■■ mime ..I l�.��i�� U h I. Ell = ��IM_ ■ r I i. 28/20 42/2 34 20 m i ME iiimmwommummummiu 20 1101■ Q ` IEI 38 2D ' itnim._ Nil � � imi in.■■.■■■. 5,4 4 . li7 19a CFM 42/ 8 „� 8X8 Sp - 0 �i. .1I � m iiy �iikaii � %iii IIII ��► � ;- L_111 10 ..._.��,,. ...� ���. 12X12 RDF ��iII`�' ::=1 w � ii r� �J.. or-Aw 8 „� © 0 8X8 S I . ` _.►� - (TYP. ) �■_ .. ...‘,,,,:v:.,......,../.. ,1I CENTREX EXHAUST FAN 650 CFM Q .375” S.P. HP, 120 V 1. ZONE AND DIFFUSER SCHEDULE TRANE SQ BOX # FT VCBC -20 -M 1320 CFM VCBC-08-F 370 580 CFM VCBC -02 -A 140 220 CFM VCBC -04 -F 240 370 CFM VCBC -20 1650 CFM THERMOSTATS: TAC (FORMERLY INVENSYS) T18-3081 OR EQUAL. REFERE 109 - 101 -4564 M2 CO STRUCTIO\ DUCT # OF CFM/ SIZE DIFF'S DIFFUSER 840 12” 6 220 5 "" 1 220 6" 2 185 6" 1 270 6" 2 225 1060 12" 3 550 CE DRAWI\ DIFFUSERS ARE SHOWN IN THEIR RELOCATED POSITIONS. SEE M 1 M456R FOR RELOCATION INFORMATION. \OTES RELOCATE THREE VAV BOXES AND MODIFY ADJACENT DUCTWORK AS SHOWN, LOCATING BOXES TO MINIMIZE LENGTH OF FLEX DUCTS. INSULATE NEW DUCT TO MATCH EXISTING. INSTALL TWO 2' X 2' RETURN GRILLES WHERE SHOWN. INSTALL NEW THERMOSTATS FOR ALL 8 ZONES WHERE SHOWN. REBALANCE SYSTEM TO AIRFLOWS SHOWN. ALSO MEASURE TOILET EXHAUST CFM. BY HARR HARR APPROVED RWS RWS DATE 06/18/07 06/18/07 SYM REVISION BY APPROVED DATE � Q BOE /N cs ��AIR HANDLING UNIT TRANE #12 -A -7000 CFM @ 21 S.P., 5 HP, 480V 30 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY GREENHECK BCF 108 1HP 115/1 1000 CFM DEPT. DATE r I AHU Xi DRAWN S.RUDELL CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 06.11.07 18/10 SUBTITLE TITLE Dulw HVAC - MEZZANINE PLAN BUILJI\G 9 -101. VI CURRENT REVISION 16062100 KEY PLAN IIII�' 'VIII III II�� SYMBOL B SHEET v 1 V 56 JOB NO. 16062100 n COMP NO. RECEIVED CITY OF TUKWILA OCT 2 5 2007 PERMIT CENTER DATE 06/18/07 HVAr Mezzanine Plan n. :1 .l ...,.. t"'....4........... _t 5A /A ,.--. F..,. ..... -....a l�... .- .....n n.- .n.... M MECHANICAL MASTER COL. G-J/13-15 D C DWG NO. 9- 101- M1M456