Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-230 - BOEING #9-101
BOEING #9 -101 9725 EAST MARGINAL wys M07 -230 Parcel No.: 0003400018 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 9725 EAST MARGINAL WY S TUKW BOEING #9-101 9725 EAST MARGINAL WY S , TUKWILA WA BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 Contact Person: Name: JESICA ROGERS Address: 1221 2 AV N , KENT WA Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA Contractor License No: HERMACLOO5BJ DESCRIPTION OF WORK: REROUTING DUCT WORK TO SIX EXHAUST FANS Value of Mechanical: $7,500.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/WaIIJFloor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10 /06 Citf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT rOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 575 -9700 Phone: 206 - 575 -9700 Expiration Date: 08/25/2008 M07 -230 02/07/2008 08/05/2008 Fees Collected: $246.53 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -230 Printed: 02 -07 -2008 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied doc: IMC-10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http:• / /www.ci.tukwila.wa.us Permit Number: MO7 -230 Issue Date: 02/07/2008 Permit Expires On: 08/05/2008 Date: 024 4101 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructs o the perfo e of work. I am authorized to sign and obtain this mechanical permit. Signature: 1. nn K..i r Date: Z / 1 IC'T Print Name: D L' 9 e. S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende4 or abandoned for a period of 180 days from the last inspection. M07 -230 Printed: 02 -07 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #9 -101 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -230 Status: ISSUED Applied Date: 10/26/2007 Issue Date: 02/07/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond - 10/06 * *continued on next page ** M07 -230 Printed: 02 -07 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Date: 1/o ordinances governing or local laws regulating doc: Cond -10/06 M07 -230 Printed: 02 -07 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 lutp://www.citukwila.wo.us Name: 6e t 5 Mailing Address: 1221 2nd Ave. N. Kent. WA 98032 E -Mail Address S Ghermanson.com Company Name: Hermanson Co. LLP Mailing Address: 1221 2nd Ave. N. Kent, WA 98032 Contact Person: Dani Meyers E -Mail Address: dmeyerschermanson.com Contractor Registration Number: HERMACLOO5BJ Company Name: Mailing Address: Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Property Owners Name: Boeing Mailing Address: 9725 E. Marginal Way S. Building 9 -101 Contact Person: E -Mail Address: E -Mail Address: QAApplications\Forms- Applications On Line0-2006 - Permit Application.doc Revised: 9 -2006 bh Kine Co Assessor's Tax No.: OOb t 00 9725 E. Marginal Way S. Building 9 -101 Site Address: Suite Number: 490A- Floor: Tenant Name: Boeing 9 -101 New Tenant: El Yes ❑ ..No City State CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 206- 575 -9700 Fax Number: 206- 575 -9800 Cit GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) City Day Telephone: 206- 575 -9700 Fax Number: 206 - 575 - 9800 Expiration Date: 08/25/07 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record State City Day Telephone: Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: E Q( rr � � � /� Mailing Address:900 1 -1 01 F Y [ C Stt 1C)O ` City ++ __ alp Contact Person: Day Telephoneou " ` 1 � .lt ^ t - zi / �� /'� � /' Fax Number: at lJt— I] n l. v v v `mil b Zip Tin Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Use: Residential: New .... ❑ Commercial: New .... - MECHANICAL PERMIT INFORMATION- 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Co. LLP Mailing Address: 1221 2nd Ave. N. Kent. WA 98032 Contact Person: Dani Meyers E -Mail Address: dmeyers ©hermanson.com Contractor Registration Number: HERMACLOO5BJ Valuation of Mechanical work (contractor's bid price): $ 5l- O Scope of Work please provide detailed formation r-e,ro tyrifY1 c cC t Lct r (�D Fuel Type: Electric ❑ Gas.... Q: Applications\Forns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Replacement ... Replacement .. Indicate type of mechanical work being installed and the quantity below: City c• °• ° -? Day Telephone: 206- 575 -9700 Fax Number: 206- 575 -9800 Expiration Date: 08/25/07 Other: Page 4 of 6 I PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O�V1� ,y Signature: \ `�'r�� \ v l t Print Name. \*tS �� OO Mailing Address: 1221 2nd Ave. N. Kent, WA 98032 Q:\ Applications\Fottns-Applications On Line\3.2006 - Permit Application.doc Revised: 9.2006 bit Date: iV I Telephone: 206 -575 -9700 City State Zip Date Application Accepted: tolukol— Date Application Expires: Staff Initials: Page 6 of 6 Parcel No.: 0003400018 Permit Number: M07 -230 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 10/26/2007 Applicant: BOEING #9 -101 Issue Date: Receipt No.: R07 -02348 Initials: JEM Payment Date: 10/26/2007 01:13 PM User ID: 1165 Balance: $0.00 Payee: BERMANSON COMPANY LLP TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Payment Amount: $246.53 Amount Payment Check 54616 246.53 Account Code Current Pmts 000/322.100 203.22 000/345.830 43.31 Total: $246.53 doc: Receiot -06 Printed: 10 -26 -2007 Pro OQX /!t/ 16 Type of� % — / }� I Address: Q725 94.5- /al4I' Date Called: Special Instructions: / Date Wanted: t m) Q� / p.m. 47/ d Requester: Phone No .0K -:3 -3-5 y �2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. COMMENTS: 1 ,0 AX77 i ' € ' ' . l rrections required prior to approval. Date 4- vi( El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Proj t: Type of spection% �114- J + jU Address: 72S L45/ / Date Called: Special Instructions: Date Wanted: 3 / - o A a.m ( Requester: Phone No: 0 6 -375 - ?syy CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: I'spec INSPECTION RECORD lxitain a copy with permit INSPECTION NO. • PERMIT NO. Approved per applicable codes. El Corrections required prior to approval. $5:.00 REINSPECTIO FEE R(l RED. Prior to inspection. fee must be p • id at 6300 Southcen r Blvd., uite 100. Call the schedule reinspection. Re -ipt No.: /,7d 7036 'Date: October 30, 2007 Jesica Rogers 1221 2 Av N Kent WA 98032 RE: Letter of Incomplete Application # 1 Development Permit Application M07 -230 Boeing #9-101 — 9725 East Marginal Wy S Dear Ms. Rogers: This letter is to inform you that your permit application received at the City of Tukwila Permit Center on October 26, 2007 is determined to be incomplete. Before your application can continue the plan review process the attached items from the following department needs to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenEer service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Enclosures File: M07 -224 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director P:1Permit Center\lncomplete Letters\2007\M07 - 230 Incomplete Ltr #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -366' Determination of Completeness Memo Date: October 30, 2007 Project Name: Boeing #9 -101 Permit #: M07 -230 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Revise plan code notes to show compliance with the current 2006 International Building Codes. In addition the plan design shall conform to the current 2006 building and energy codes. Should there be questions conceming the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. ACTIVITY NUMBER: M07 - 230 DATE: PROJECT NAME: BOEING #9 -101 SITE ADDRESS: 9725 EAST MARGINAL WAY S Original Plan Submittal Response to Correction Letter # Revision # 01 -16 -08 X Response to Incomplete Letter #_ After Permit Issued DEP RTMENTS: III Build / Divi' ion Public Works Complete TUESJTHURS ROUTING: Please Route Documents/routing slip.doc 2 -2 &02 I'EHMR COORD COPY PLAN REVIEW /ROUTING APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Fire Prevention Structural Incomplete Structural Review Required DETERMINATION OF COMPLETENESS: (Tues., Thurs.) SLIP Planning Division ❑ Permit Coordinator DUE DATE: 01 -22 -08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 02 -19-08 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: \.- PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -230 DATE: 10 -26 -07 PROJECT NAME: BOEING #9 -101 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bui ing Division Public Works 4115eJPret ventio�n Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Incomplete ❑ Comments: TUES/THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 DATE: DATE: Planning Division Permit Coordinator DUE DATE: 10-30-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: its (JO )tPt LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bld Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 11-27-07 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: / - D8 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: /!w►twv.ci.tukwila.wa.us 1 REVISIOPT SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M07 -230 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M. Mullet, Mayor Steve Lancaster, Director Project Name: Boeing #9 -101 Project Address: 9725 East Marginal Wy S / Contact Person: J S=e/t /2 0 G d Phone Number: [ 2003 5 9700 Summary of Revision: , pi4T-1E7 cope REFEReacC ro zoo KtCE VED CITY OF TUKA JAN 16 21103 f4lI CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ` 1 9R_6(41 E' Entered in Permits Plus on -16 ' 0 lapplicationsVorms •applications on Iine4evision submittal Created: 5- 13.2004 Revised: License Information License HERMACLOO5BJ Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 1221 2ND AVE N Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC`217NT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HERMANSON, RICHARD L PARTNER/MEMBER 01/01/1980 Bond Amount ALMON, KEVIN PARTNER/MEMBER 01/01/1980 MACDONALD, JAMES PARTNER/MEMBER 01/01/1980 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date r - 7 swr' Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= HERMACL005BJ 02/07/2008 SYM A B vice ITY v AP ` ' n- • 9 -53 o p tp OXBOW LOT z 440 EXIT 158 v J • rn N 4 1 L 5 BOEING ACCESS RD • e 99 ❑❑ 0 99 FROM SEATTLE— TACOMA AIRPORT CEVELOP v EAST MARGINAL WAY CORPORATE PARK E \TAL FROM DOWNTOWN SEATTLE CE\ 599 TUKWILA TER PROJECT SITE 900 EXIT 157 EXIT 158 FROM KENT & AUBURN NO SCALE EXIT 157 900 REVISION 9 -101 ENHANCEMENTS(WP -5 TOILET ROOMS)J# DCA -9 -05013 CODE YEAR CHANGE J# DCA -9 -05013 BY DLR GROUP DLR GROUP APPROVED LS LS DATE 12.16.05 01.15.08 SYM BOEING WORKPLACE SERVICES BUILDING 9 -101 WORK PACKAGE #2 (LOBBY) - J#DCA-9-0501 3 AREA v1AP BUIL�I \G A 9725 EAST vARGI T., '<WILA, WA 9-101 KILDI\ S CRESS: AL WAY SCUT \GTO\ PROJECT SITE G LCICATIO\ NO SCALE REVISION BY APPROVED BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 DATE QLBOE /NG° d � REVISION AREAS ONLY AS INDICATED REGISTERED A• CHITEC ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE \ CU GE\ ERAS OTES 1. THE GENERAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS WITHIN THE AREA OF WORK BEFORE COMMENCING ANY WORK AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. THE CONTRACTOR SHALL BRING DISCREPANCIES ON THE DRAWINGS OR SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY ONLY IF THEY REQUIRE DESIGN REVISIONS. 2. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH —IN REQUIREMENTS FOR MATERIALS OR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. 3. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED OR WILL BE REMOVED PRIOR TO THE BEGINNING OF THE WORK FOR THIS PROJECT. A COPY OF THE REPORT OF THE SURVEY WILL BE FURNISHED TO THE CONTRACTOR AT THE TIME OF BIDDING OR NEGOTIATIONS. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DISCOVERED OR DAMAGED THAT IS REQUIRED TO BE REMOVED TO SUPPORT THE WORK OF THIS PROJECT. 4. THE GENERAL CONTRACTOR SHALL OBTAIN AND MAINTAIN A FULL SET OF CONSTRUCTION DOCUMENTS ON SITE. THIS SET SHALL BE MARKED UP (RED — LINED) DAILY WITH ANY ACTUAL WORK OR INSTALLATIONS DIFFERING FROM THE CONSTRUCTION DOCUMENTS. SAID SET SHALL BE TURNED OVER TO THE BOEING CONSTRUCTION PROJECT MANAGER AT THE COMPLETION OF THE WORK FOR INCORPORATION INTO BOEING RECORD DOCUMENTS. 0•14 , z) PROJ -_CT CHEC 4LIST CHECK BOX ® THESE DRAWINGS CONFORM TO THE 2003 I.B.C. CODES AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ❑ ROOMS LABELED PER OCCUPANCY PER I.B.C. 302.1. ❑ BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ❑ NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. GENERAL PERMIT (SHELL & CORE) ❑ 4 SETS OF STRUCTUAL REPLACEMENT DRAWINGS ® 2. TENANT IMPROVEMENT (NON— STRUCTURAL): ❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS. ❑ 4. MECHANICAL, 4 COMPLETE SETS. ❑ 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. ® BRIEF PROJECT NARRATIVE: THE SCOPE OF WORK FOR THIS PROJECT WILL INCLUDE ARCHITECTURAL, ELECTRICAL AND MECHANICAL WORK WITHIN THE 9 -101 BUILDING. WORK TO INCLUDE TENANT IMPROVEMENTS AND DEVELOPMENT OF A NEW NORTH ENTRY LOBBY TO THE 9 - 101 BUILDING. PROFESSIONAL STA v1P & SIGNATURE APPLIES TO WORK WTHIN THE CLOUDED DRAWN EDDIE P. DUARTE CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 07.29.05 SUBTITLE TITLE No chances si •y ` o :? t thr scope I 01 work w i . .' :c i ' i'Dr - o of Tu:i.il�iia Bu D N OTE : Revisions lvili require a new plan submittal ; and may include additional plan review tees. 6 SEPARATE PERMIT REQUIRED FOR: Cl echanical L� lectrical Las LGas Piping City of Tukwila BUILDING DIVISION DESIG\ TEA v OWNER: el._ BOE,�w 0 BOEING DEVELOPMENT CENTER UTH 9725 EAST MARGINAL WAY SO TUKWILA, WASHINGTON 98108 WORK PACKAGE #2 PROJECT MANAGER TWILA WOLLENSEN TEL: 206.459.6731 ARCHITECTURAL, MECHANICAL, � DLR Grou p Architecture Engineering Planning Interiors AND ELECTRICAL: DLR GROUP 900 FOURTH AVENUE SUITE 700 SEATTLE, WASHINGTON 98164 TEL: 206.461.6000 FAX: 206.461.6049 WWW.DLRGROUP.COM COME S VV ARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT TUNNEL FIRST FLOOR MEZZANINE SECOND FLOOR BUILDING GROSS EFFECTED AREA BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC DESIGN CATEGORY: WIND EXPOSURE: TUKWILA I.B.C. CODES AND THE WAC 51 -20 AS TED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B AND GROUP F, DIVISION 1 (OFFICE AND FACTORY) TYPE II —B, NON — COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 1,116,306 (UNLIMITED PER IBC 507.3) 713,829 50,910 713,829 55,689 295,878 1,116,306 NORTH ENTRY LOBBY AREA MODIFICATIONS OF APPROXIMATELY 4158 SQUARE FEET. 111 FT. MAXIMUM 2 OVERALL (NO CHANGES) BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT D C INCOMPLETE ISSUE FOR CONSTRUCTION ARCHITECTURAL MASTER COVER SHEET 9 - 101 ENHANCEMENTS (WP -2 LOBBY) BUILDING 9 -101 FILE C Ply Permit No. M � 1 i3° Plar review approve! is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adapted code or cane. Receipt of approv F d Copy conditions is BY die Date: MO7 23o DLR Group Architecture Engineering Planning Interiors CURRENT REVISION SYMBOL J #DCA -9 -05013 City of Tukwila BUILDING DIVISION RECMPED JAN 16 Zoos PERM T CENTER 01.15.08 CC m 0 SYM B INCLUDED IN SET • • • O O O O O O O DRAWING NO. 9- 101 —GO 9- 101 —G1 9- 101 —G2 9-101-1A01 9- 101- -1 A13R 9- 101 -1 A14R 9- 101- 1A283R 9- 101- 1A284R 9-101-1A1 3 9- 101 -1A14 9- 101 -1A283 9- 101 -1A284 9- 101 —A214 9- -101 —A215 9- 101 —A359 9- 101 —A360 9- 101 —A380 9- 101 —A457 9- 101 —A565 9- 101 —A566 SHEET NO. GO G1 G2 1A01 1A13R 1 A14R 1A283R 1A284R 1A13 1A14 1A283 1A284 A214 A215 A359 A360 A380 A457 A565 A566 REVISION REISSUE MECH'L PERMIT DRAWINGS J# DCA-9-05013 GE ERAL DRAWING TITLE COVER SHEET INDEX OF DRAWINGS SYMBOLS, ABBREVIATIONS, GENERAL NOTES ARCHITECTURAL FIRST FLOOR COMPOSITE PLAN FIRST FLOOR REMOVAL PLAN FIRST FLOOR REMOVAL PLAN FIRST FLOOR REFLECTED CEILING REMOVAL PLAN FIRST FLOOR REFLECTED CEILING REMOVAL PLAN FIRST FLOOR PLAN FIRST FLOOR PLAN FIRST FLOOR REFLECTED CEILING PLAN FIRST FLOOR RELFECTED CEILING PLAN WALL TYPES AND SECTIONS WALL AND BUILDING SECTIONS RM. FINISH AND COLOR AND MATERIAL SCHEDULE DOOR SCHEDULE, NOTES, TYPES, AND DETAILS INTERIOR ELEVATIONS ENLARGED FIRST FLOOR NORTH LOBBY PLAN MISCELLANEOUS DETAILS MISCELLANEOUS DETAILS BY DLR GROUP APPROVED LS DATE 01.15.08 SYM 01.15.08 01.15.08 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 INCLUDED IN SET • • • • • • REVISION D DRAWING NO. 9- 101 -1M13R 9- 1O1 -1M63R 9- 101- 1M113R 9- 101 -1M13 9- 101 -1M63 9- 101 -1M113 BY APPROVED xo SHEET NO. 1M13R 1M63R 1M113R 1M13 1M63 1M113 DATE v EC A\ D R A DRAWING TITLE STRUCTURAL CAL FIRST FLOOR HVAC DUCT REMOVAL PLAN FIRST FLOOR HVAC PIPING REMOVAL PLAN FIRST FLOOR PLUMBING REMOVAL PLAN FIRST FLOOR HVAC DUCT PLAN FIRST FLOOR HVAC PIPING PLAN FIRST FLOOR PLUMBING PLAN ,6 BOE /NG - REV DATE c C 01.15.08 B 01.15.08 K 01.15.08 C 01.15.08 B 01.15.08 K 01.15.08 INCLUDED IN SET APPROVED BY DRAWING NO. SHEET NO. O 9- 101- -1 E13R O 9- 101 -1E63R O 9-101-1E13 O 9- 101 -1E63 O 9- 101 —E591 ACCEPTABILITY i f THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE APPROVED APPROVED 1 E13R 1E63R 1E13 1E63 E591 DRAWN DLR GROUP CHECKED LS ENGINEER CHECKED DATE 11.06.05 12.16.05 ELECTRICAL DRAWING TITLE FIRST FLOOR LIGHTING REMOVAL PLAN FIRST FLOOR POWER REMOVAL PLAN FIRST FLOOR LIGHTING PLAN FIRST FLOOR POWER PLAN LIGHT FIXTURE SCHEDULE & MISC. ELECT. DETAILS TITLE ARCHITECTURAL MASTER BUILDING 9 -101 REV ORIG ISSUE FOR CONSTRUCTION 9 -101 ENHANCEMENTS (WP -2 LOBBY) DATE 12.16.05 12.16.05 12.16.05 12.16.05 12.16.05 SU BTITLE INDEX OF DRAWINGS DEV. CENTER, WA DWG NO. CODE C�i ti SHEET JOB NO. PREL ORIG A c O • CURRENT REVISION # DCA -9 -05013 G1 ISSUE LEGEND NOT YET ISSUED PREVIOUSLY ISSUED, BUT NOT IN THIS ISSUE INCLUDED IN THIS ISSUE DLR Group Architecture Engineering Planning Interiors SYMBOL J# DCA -9 -05013 PRELIMINARY ISSUE FOR REVIEW OR INFORMATION ONLY NOT FOR CONSTRUCTION ORIGINAL ISSUE FOR PERMIT, BID, PRODUREMENT OR CONSTRUCTION DRAWING REVISION — SEE SPECIFIC DRAWING FOR NATURE OF REVISION 09 101 — Q1 . :D JAN 16 2008 PE;-Mi T CENTER DATE 01.15.08 COMP NO. J XXXX 7 us K) O 0 • DETAIL DESIGNATION SHEET NUMBER WHERE DETAILED (IF SAME AS SHEET REFERENCED FROM) SECTION /DETAIL DESIGNATION XXXXX XXXXX- SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM ELEVATION DATUM OR SPOT ELEVATION REVISION NORTH ARROW SECTION /DETAIL DESIGNATION BUILDING, WALL SECTIONS AND DETAIL REFERENCES SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM REFERENCE TO DETAIL /ENLARGED PLAN 1 CEILING HEIGHT A.F.F. ROOM NAME ROOM NUMBER DOOR NUMBER WALL TYPE LEGE GRID /GRID BUBBLE AND CENTERLINE CONSTRUCTION ABOVE OR BELOW, BEYOND OR BEHIND (HIDDEN) CONSTRUCTION "FLAG" NOTE FOR SPECIFIC CONSTRUCTION DIRECTIVE GENERAL "BOAT" NOTE FOR SPECIFIC OR EXISTING HISTORICAL INFORMATION. WINDOW TYPE FIRE EXTINGUISHER FIRE EXTINGUISHER & CABINET SUPPLY AIR DIFFUSER RETURN AIR GRILLE FLOURESCENT LIGHT FIXTURE (PENDANT MOUNTED) FLOURESCENT LIGHT FIXTURE (PENDANT MOUNTED) FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT LIGHT (NL) CIRCUIT RECESSED OR PENDANT LIGHTING FIXTURE RECESSED OR PENDANT LIGHTING FIXTURE FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT LIGHT (NL) CIRCUIT WALL SCONCE 1 WALL SCONCE 2 EXIT SIGN (CEILING UNIT) EXIT SIGN (WALL MOUNT) CEILING MOUNTED OCCUPANCY SENSOR SWITCH, OS INDICATES INTEGRAL OCCUPANCY SENSOR, D INDICATES INTEGRAL DIMMER INTERCOM /SPEAKER 15A, 120V DUPLEX RECEPTACLE 20A, 120V, DUPLEX RECEPTACLE 15A, 120V, FOURPLEX RECEPTACLE FIRE ALARM HORN /STROBE, xx INDICATES CANDELA RATING DATA /TELEPHONE OUTLET FIRE SPRINKLER HEAD BY D/sY V INTERIOR ELEVATION (WHERE SPACE IS LIMITED) APPROVED BOLS DATE SYM [::::::) TOILET 0 DF G 0 0 == C 3 HANDICAP GRAB BAR, 1 1/2" O.D. 0 EARTH, DIRT, UNDISTURBED EARTH, DIRT, COMPACTED STONE, GRAVEL, POROUS FILL BRICK, COMMON CERAMIC TILE CONCRETE INSULATION: BATT, LOOSE FILL, BLANKET INSULATION: RIGID ALUMINUM BRASS, BRONZE, COPPER METAL, STEEL, IRON PLASTER: SAND, CEMENT, GROUT PLASTER: GYPSUM WALL BOARD WOOD: FINISH V I I I I Ti l I I I I I Wo eONT,6 ROOF /ACCESS HATCH URINAL LAVATORY MOP SINK DRINKING FOUNTAIN SANITARY NAPKIN /TAMPON DISPENSER PAPER TOWEL DISPENSER /DISPOSAL DOUBLE ROLL TOILET PAPER DISPENSER TOILET SEAT COVER DISPENSER WOOD: ROUGH CONTINUOUS WOOD: INTERRUPTED BLOCKING PLYWOOD: SMALL SCALE PLYWOOD: LARGE SCALE WALL TYPE: CONCRETE MASONRY (CMU) WALL TYPE: STEEL STUD �-_-� WALL TYPE: WOOD STUD WALL TYPE: EXISTING WALL TYPE: REMOVAL 3 3 WALL TYPE: PARTITION (7' -0" HIGH) WALL TYPE: GLASS REVISION BY APPROVED DATE AB ADJ AFF AGG AL ALT AN CH APA APPD APPROX ASTM BTWN BLDG BLKG BOT C CB CC CEM CF CJ CL CLG CLR COL COMP CONC CONN CONST CONT CONTR CTSK CY `/5, DIA DBL DEMOL DEP DIA DIAG DIM DL DN DS DWG E EA EB EF EJ EL ELEV EQ EW EXIST EXP EXT FAS FF FF FGR FH FIN FND FOC FOF FOIC FO FRO FT FTG FUT FV GA GALV GC GI GR GT GWB HDNR HDWD HDWR HG HM HOR HS HT IBC ID ID IF IN INCL AND AT ANCHOR BOLT ADJACENT ABOVE FINISHED FLOOR AGGREGATE ALUMINUM ALTERNATE ANCHOR, ANCHORAGE AMERICAN PLYWOOD ASSOC. APPROVED APPROXIMATE AMERICAN SOCIETY OF TESTING MATERIALS BETWEEN BUILDING BLOCKING BOTTOM CHANNEL CATCH BASIN CENTER TO CENTER CEMENT CUBIC FEET CONTROL JOINT CENTER UNE CEILING CLEAR(ANCE) COLUMN COMPRESS(ED) (ION) CONCRETE CONNECTION CONSTRUCTION CONTINUOUS, CONTINUE CONTRACT(OR) COUNTERSUNK CUBIC YARD(S) DIAMETER DOUBLE DEMOLISH, DEMOLITION DEPRESSED DIAMETER DIAGONAL DIMENSION DEAD LOAD DOWN DOWNSPOUT DRAWING EAST (COORDINATE) EACH EXPANSION BOLT EACH FACE EXPANSION JOINT ELEVATION ELEVATION EQUAL EACH WAY EXISTING EXPOSED EXTERIOR FASTEN(ER) FACTORY FINISH FINISHED FLOOR FINISH GRADE FIRE HYDRANT FINISH(ED) FOUNDATION FACE OF CONCRETE FACE OF FINISH FURNISHED BY OWNER/ INSTALLED BY CONTRACTOR FINISHED OPENING FOR REFERENCE ONLY FOOT FOOTING FUTURE FIELD VERIFY GAGE GALVANIZED GENERAL CONTRACTOR GALVANIZED IRON GRADE GROUT GYPSUM WALL BOARD HARDENER HARDWOOD HARDWARE HIGH GRADE HOLLOW METAL HORIZONTAL HIGH STRENGTH HEIGHT INTERNATIONAL BLDG. CODE INSIDE DIAMETER INSIDE DIMENSION INSIDE FACE INCH INCLUDED(D) (ING) ABBREVIATIO JT JOINT KO L LB LEN LF LL LWR MATL MAX MB MBR MTL MFR MIN MISC MO MT MTL N NF NIC NO. NOM NTS OA 0/C OD OF OPG OPP PAR PCC PCF PERF PERIM PL PLAM PLYWD PNL PREST PRF PSF PSI PT PVC R R REF REINF REQ REV RH RO S SECT SF SHT SIM SQ SST ST STD STL STR SYM SYS T &B T &G TEMP THK TOC TOC TOL TOS TS TYP UBC UL UNO UPR VB VERT W W W/ W/0 WWF �BOE /NG° S KIP(S) KNOCK OUT LENGTH LAG BOLT LENGTH LINEAL FEET LIVE LOAD LOWER MATERIAL MAXIMUM MACHINE BOLT MEMBER METAL MANUFACTURE(R) MINIMUM MISCELLANEOUS MASONRY OPENING MOUNT(ED) (INC) METAL NORTH (COORDINATE) NEAR FACE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OPENING OPPOSITE, OPPOSITE HAND PARALLEL PRECAST CONCRETE POUNDS PER CUBIC FOOT PERFORATE(D) PERIMETER PLATE PLASTIC LAMINATE PLYWOOD PANEL PRESTRESS(ED) PREFORMED POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT, PAINT POLYVINYL CHLORIDE RADIUS (CURVATURE) RISER REFERENCE, REFER TO REINFORCE(D) (ING) REQUIRE(D) (ING) REVISION(S), REVISED RIGHT HAND ROUGH OPENING SOUTH (COORDINATE) SECTION SQUARE FEET SHEET SIMILAR SQUARE STAINLESS STEEL STRUCTURAL TEE STANDARD STEEL STRUCTURAL SYMMETRY,SYMME I RICAL SYSTEM TOP AND BOTTOM TONGUE AND GROOVE TEMPORARY THICK(NESS) TOP OF CONCRETE TOP OF CURB TOLERANCE TOP OF STEEL STRUCTURAL TUBE TYPICAL UNIFORM BUILDING CODE UNDERWRITERS' LABEL UNLESS NOTED OTHERWISE UPPER VAPOR BARRIER VERTICAL WEST (COORDINATE) WIDE FLANGE WIDTH, WIDE WITH WITHOUT WELDED WIRE FABRIC NOTE: REFER TO THE COLOR AND MATERIAL SCHEDULE FOR ADDITIONAL FINISH AND DESIGNATIONS /ABBREVIATIONS CO KRUSE ASHINGTON GE ERAL OTES 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF TUKWILA PRIOR TO COMMENCING CONSTRUCTION. 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT ADMINISTRATOR SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CLOUD(S) ON EACH SHEET. IF THERE IS NO CLOUD ON A SHEET THE ENTIRE SHEET IS IN THE SCOPE OF WORK INSOFAR AS CONSTRUCTION NOTES INDICATE. INFORMATION OR WORK (WHETHER CLOUDED OR NOT) REFERRED TO FROM WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK (I.E. - A SECTION OR DETAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEET IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL SECTION OR DETAIL DRAWN ON THE DETAIL SHEET IS NOT CLOUDED.) 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREA DESIGNATED BY THE BOEING CONSTRUCTION PROJECT MANAGER. 5. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING CONSTRUCTION PROJECT MANAGER IMMEDIATELY UPON DISCOVERY. 6. CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. 7. COMPLY WITH THE BOEING CONSTRUCTION PROJECT MANAGER AND BOEING AGREEMENTS FOR CONSTRUCTION AREA AND SECURITY REGULATIONS. 8. PROVIDE, AS IF DRAWN IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS. 9. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND /OR CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED. 10. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS DIMENSIONED OTHERWISE. 11. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED OTHERWISE. 12. PLANS WHICH APPEAR AS BACKGROUNDS ON CML, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. 13. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH -IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. 14. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN THE CONSTRUCTION NOTES. 15. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED MATERIALS TO BE REUSED IN LATER PARTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED. 16. SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL CALLOUTS. 17. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF REMOVAL OR PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND REPAIR THE EXISTING TO MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING ONES, TOP OF BASE, CHANGE IN MATERIAL OR SIMILAR. 18. ALL RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN REQUIRED FIRE RATING OF THE PARTITION AND AS REQUIRED TO MEET CURRENT REGULATORY REQUIREMENTS. 19. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL AND ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING PLANS FOR LOCATIONS OF ITEMS IN CEILING; SEE VARIOUS DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE SPECIFIC COMPONENTS INDICATED ON ARCHITECTURAL REFLECTED CEIUNG PLANS. 20. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS. 21. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND THE LIMITS OF THE ARCHITECTURAL DRAWINGS. 22. AT METAL STUD PARTITIONS, STUDS ARE TO EXTEND FROM FLOOR TO FLOOR. WHERE THEY CANNOT DO SO, DUE TO INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION; SUBMIT EQUIVALENT SUPPORT METHOD TO ARCHITECT FOR REVIEW. ALL FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OR STRUCTURE ABOVE, U.N.O. 23. REFER TO SPECIFICATIONS FOR ACCESS DOORS AND VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES OF EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT. 24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL SAFETY CODES, REGULATIONS AND BOEING REQUIREMENTS. 25. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON TO DETERMINE /DESIGN REQUIRED MODIFICATIONS TO THE FIRE SPRINKLER SYSTEM LAYOUT WITHIN THE AREA OF WORK DUE TO CHANGES IN THE FLOOR PLAN LAYOUT. SAID ENGINEER SHALL STAMP, SEAL AND CERTIFY THAT HIS /HER DESIGN IS IN COMPLIANCE W /ALL APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE AND PROVIDE ALL NECESSARY PHYSICAL MODIFICATIONS AS A RESULT OF SAID ENGINEER'S DESIGN. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DLR GROUP CHECKED LS ENGINEER CHECKED APPROVED APPROVED DATE 12.09.05 12.16.05 TITLE ARCHITECTURAL MASTER SPECIFICATIO OTATIO GENERAL: COORDINATE ALL ASPECTS OF INSTALLATION. FURNISH ALL PREFABRICATED MATERIALS AND PRODUCTS FROM A FABRICATION FIRM EXPERIENCED IN PRODUCING SIMILAR PRODUCTS TO THAT BEING INSTALLED. INSTALL USING A QUALIFIED, EXPERIENCED INSTALLER WITH A RECORD OF SUCCESSFUL IN- SERVICE PERFORMANCE PROJECTS. COMPLY WITH SPECIFIC TRADE QUALITY STANDARDS AND ALL MANUFACTURER'S PUBLISHED REQUIREMENTS / RECOMMENDATIONS. COORDINATE WORK WITH ALL OTHER RELATED BOEING REQUIREMENTS, SPECIFICATIONS AND CONTRACT AGREEMENTS. SOUND BATT INSULATION: ASTM C 665, TYPE 1 BLANKETS WITH MEMBRANE FACING PRODUCED BY COMBINING THERMOSETTING RESINS WITH MINERAL FIBERS MANUFACTURED FROM GLASS. THICKNESS TO BE 3 1/2 INCHES MINIMUM AND AS INDICATED ON DOCUMENTS. OWENS CORNING "SOUND ATTENUATION BATTS ", NON - COMBUSTIBLE, FOIL FACED. ATTACH WITH MECHANICAL FASTENERS OR ADHESIVE TO STUDS TO ONE SIDE OF THE PARTITION. FRICTION FIT IS NOT ACCEPTABLE. FILL STUD CAVITIES AND MISCELLANEOUS SPACES TO PROVIDE A COMPLETE SOUND- ATTENUATING ENVELOPE AS INDICATED ON DRAWINGS. 08710 DOOR HARDWARE: PROVIDE COMMERCIAL DOOR HARDWARE AS INDICATED OR SCHEDULED. PROVIDE PRODUCT DATA, PRODUCT CERTIFICATES, AND COORDINATE KEYING WITH THE BOEING LOCK AND KEY SHOP AND SUPPLY THE NUMBER OF KEYS AS DIRECTED BY SAID SHOP. DENVER KEYS TO THE BOEING CONSTRUCTION PROJECT MANAGER AS DIRECTED. 09260 GYPSUM WALL BOARD SYSTEMS AND TILE BACKING PANELS: STEEL FRAMING SHALL COMPLY WITH ASTM C 754 FOR CONDITIONS INDICATED WITH MANUFACTURER'S STANDARD CORROSION- RESISTANT ZINC COATING AND 20 GAUGE MINIMUM. STEEL STUDS AND RUNNERS SHALL MEET ASTM C 645, IN DEPTH INDICATED. ATTACH STEEL RUNNERS TO CONCRETE SLAB AND OVERHEAD STRUCTURE WITH SCREWS LOCATED MAXIMUM 2 INCHES FROM RUNNER ENDS AND MAXIMUM 24 INCHES ON CENTER. SUSPENDED CEILING AND SOFFIT FRAMING SHALL BE (BASED ON 10 POUNDS PER SQ. FT. LOAD) SPANS TO 10' -0" AT 16" O.C. OF 4" WIDTH, 25 GAUGE STUDS. TIE WIRE OF .06125 -INCH DIA. CLASS 1 ZINC COATED, SOFT TEMPER. CARRYING CHANNELS OF COLD-ROLLED, COMMERCIAL -SHEET OF .0538 INCH MINIMUM IN SIZES INDICATED. FURRING CHANNELS TO BE HAT - SHAPED, RIGID TO MEET ASTM C 645, 7/8 INCH DEEP. PROPRIETARY FLEXIBLE TRACK TO BE 20 -GAUGE BY WIDTH INDICATED "C" OF AVAILABLE PRODUCTS AS PRODUCED BY FLEX - ABILITY CONCEPTS, "FLEX -C TRAC ". DEEP -LEG DEFLECTION TRACK TO MEET ASTM C 645 WITH 2 INCH DEEP FLANGES. GYPSUM WALL BOARD (GWB) SHALL BE 5/8" TYPE X WITH LONG EDGES TAPERED AND MEET ASTM C 36. CURVED WALLS /SOFFITS SHALL BE OF FLEXIBLE WALL BOARD TO FIT A TIGHT RADII WITH DOUBLE LAYER OF 1/4 INCH THICK BOARD. WATER RESISTANT GYPSUM BOARD OF 5/8 INCH TYPE "X" TO MEET ASTM C 630/C630M. TILE BACKING PANELS TO BE CEMENTMOUS, 1/2 INCH, SMOOTH FACE TO MEET ANSI A118.9. ALL TRIM ACCESSORIES TO MEET ASTM C 1047. WALL STUD ERECTION SHALL CONFORM TO MANUFACTURE'S PRINTED RECOMMENDATIONS. WALL BOARD JOINTS SHALL BE TAPED, SANDED SMOOTH AND PREPARED FOR PAINTING, 09511 METAL PANEL CEILINGS: REMOVAL AND ANY RECYCLING OF EXISTING CEIUNG GRID AND /OR PANELS IS STRICTLY THE RESPONSIBILITY OF THE CONTRACTOR. PROVIDE PRODUCT DATA FOR EACH NEW PRODUCT INDICATED. PRODUCTS SHALL MEET FIRE - TEST - RESPONSE CHARACTERISTICS TO COMPLY WITH ASTM E 1264 FOR CLASS A MATERIALS WHEN TESTED PER ASTM E 84 WITH SMOKE DEVELOPMENT INDEX OF 450 OR LESS. CEILINGS PLUS "RADIANS" IS THE BASIS OF DESIGN. PRODUCTS MANUFACTURED BY USG INTERIORS, ARMSTRONG WORLD INDUSTRIES, INC. OR BPB AMERICA, INC. OF PRODUCT MATCHING SPECIFICATIONS OF THE "RADIANS" PRODUCT CAN BE CONSIDERED FOR USE IN THIS PROJECT. INSTALL PRODUCTS AS INDICATED ON THE DRAWINGS AND COORDINATE WITH THE REFLECTED CEILING PLANS FOR LOCATIONS /LAYOUT. REFER TO THE MATERIALS AND COLOR SCHEDULE FOR SPECIFIC PRODUCT INFORMATION. HANGER WIRE TO BE CLASS 1 ZINC COATED CARBON- STEEL, SOFT TEMPER. GRID MAIN AND CROSS RUNNERS SHALL BE ROLL FORMED FROM COLD- ROLLED STEEL SHEET, PREPRINTED, ELECTROLYTICALLY ZINC COATED TO MEET ASTM A 653/A 653M AND SHALL BE OF HEAVY -DUTY CLASSIFICATION. 06402 INTERIOR ARCHITECTURAL WOODWORK: INCLUDES WOOD FURRING, BLOCKING, SHIMS, AND HANGING STRIPS FOR INSTALUNG WOODWORK ITEMS, UNLESS CONCEALED WITHIN OTHER CONSTRUCTION BEFORE WOODWORK INSTALLATION. COORDINATE ALL ASPECTS OF MOUNTING SUPPORT FOR INSTALLATON. SUBMIT SAMPLES FOR VERIFICATION: LUMBER OF 5 INCHES BY 24 INCHES CUT PIECES OF EACH SPECIES FINISHED ON ONE SIDE AND ONE EDGE; WOOD VENEER FACED PANELS OF 12 INCHES BY 24 INCHES WITH AT LEAST ONE FACE VENEER SEAM; AND WOOD AND METAL DECORATIVE PANEL PIECES 12 INCHES BY 10 INCHES FOR EACH TYPE , COLOR, PATTERN, AND SURFACE FINISH. FURNISH FROM A FABRICATION FIRM EXPERIENCED IN PRODUCING SIMILAR WOODWORK TO THAT BEING INSTALLED. COMPLY WITH AWI'S "ARCHITECTURAL WOODWORK QUALITY STANDARDS" AND PROVIDE ASSOCIATED PROGRAM CERTIFICATION THAT WOODWORK COMPLIES WITH REQUIREMENTS OF CUSTOM GRADE. WOOD SPECIES SHALL BE BIRCH, PLAIN SAWN OR SLICED (STAINED TO MATCH ARCHITECT'S SAMPLE). 09653 RESILIENT WALL BASE AND MOLDING ACCESSORIES: PROVIDE PRODUCT DATA AND SAMPLES OF EACH TYPE OF PRODUCT INDICATED. SAMPLES TO BE A MINIMUM OF 12 INCHES IN LENGTH OF EACH RESILIENT PRODUCT COLOR, TEXTURE, AND PATTERN REQUIRED. INSTALL AS PER PUBLISHED RECOMMENDATIONS OF THE MANUFACTURER AFTER OTHER FINISHING OPERATIONS, INCLUDING PAINTING, HAVE BEEN COMPLETED. JOHNSONITE PRODUCTS ARE THE BASIS OF DESIGN. OTHER MANUFACTURERS MAY BE USED UPON APPROVAL OF PRE -BID SUBSTITUTION REQUEST. COLORS AND PATTERNS ARE AS INDICATED BY THE MANUFACTURER'S DESIGNATION ON THE COLOR AND MATERIALS SCHEDULE. RESIUENT WALL BASE SHALL BE RUBBER, THERMOPLASTIC, CROUP 1 OR II, STRAIGHT (TOELESS) WITH BOTTOM REVEAL RECESS, 6 INCHES HIGH AND 0.125 MINIMUM THICKNESS. OUTSIDE CORNERS TO BE JOB FORMED OR PREMOLDED AND INSIDE CORNERS TO BE JOB FORMED. RESILIENT MOLDING ACCESSORY SHALL BE RUBBER FROM MANUFACTURER'S STANDARD FOR CONDITION OF USE. CARPET EDGE FOR GLUE -DOWN APPLICATIONS AND REDUCER STRIP FOR RESILIENT FLOOR COVERING JOINER FOR TILE AND CARPET. APPLY WALL BASE IN LENGTHS AS LONG AS PRACTICABLE WITHOUT GAPS OR SEAMS AND WITH TOPS OF ADJACENT PIECES AUGNED. APPLY WALL BASE TO WALLS, COLUMNS, PILASTERS, CASEWORK AND CABINETS IN TOE SPACES, AND OTHER PERMANENT FIXTURES IN ROOMS AND AREAS WHERE BASE IS REQUIRED. 09912 PAINTING: INCLUDES FIELD PAINTING OF EXPOSED INTERIOR ITEMS AND SURFACES. FIELD APPLIED WATER BASE PAINTS MAY BE APPLIED DURING BOEING'S REGULAR WORKING HOURS. OIL BASE PAINTS OR STAINS SHALL BE APPLIED AFTER HOURS AT TIMES APPROVED BY BOEING PROJECT CONSTRUCTION MANAGER. PROVIDE PRODUCT DATA FOR EACH PRODUCT INDICATED AND BENCHMARK SAMPLES FOR EACH TYPE OF COATING. DUNN EDWARDS PAINT IS THE BASIS OF DESIGN. COLORS AND FINISHES ARE AS INDICATED ON THE COLOR AND MATERIAL SCHEDULE IN THE DRAWINGS AND AS REQUIRED TO MATCH ARCHITECT'S SAMPLE. PROVIDE MANUFACTURER'S BEST - QUALITY PAINT MATERIAL OF THE VARIOUS COATING TYPES SPECIFIED THAT ARE FACTORY FORMULATED AND RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED. PROVIDE BLOCK FILLERS, PRIMERS, AND FINISH -COAT MATERIALS THAT ARE FULLY COMPATIBLE WITH ONE ANOTHER, SUBSTRATES AND PAINTS INDICATED. DO NOT PAINT PREFINISHED ITEMS, SHOP FINISHED MATERIALS, CONCEALED SURFACES (UNO), FINISHED METAL SURFACES, OPERATING PARTS, AND LABELS. STOREFRONT SYSTEM TO BE EFCO #960 SYSTEM OF 1 3/4" X 6 5/8" OF CLEAR ANODIZED ALUMINUM. ANGLE PIECES SHALL BE PROVIDED OF ALUMINUM BREAK METAL SHAPES TO MATCH COLOR AND APPEARANCE OF THE EXTRUDED MEMBERS. CORRUGATED PERFORATED COLORED METAL PANELS TO BE AS DISCRIBED ON THE SCHEDULE AND INSTALLED AS INDICATED ON THE DRAWINGS. CORRUGATED WALL GUARD METAL SHALL BE FACTORY FINISHED HOT DIPPED GALV. INDICATED ON THE DRAWINGS REFER TO THE COLOR AND MATERIALS SCHEDULE FOR INFORMATION ON PRODUCT AND FINISH INDICATIONS. ISSUE FOR CONSTRUCTION SUBTITLSYMBOLS, ABBREVIAON GENRAL NOTES & J SP E C IFICA TI TION S N OTATIO N E 9 -101 ENHANCEMENTS (WP -2 LOBBY) BUILDING 9 -101 12,1 6,05 CURRENT REVISION SHEET JOB NO. J DWG NO. DLR Group Architecture Engineering Planning Interiors G2 DCA -9 -05013 09- 101 --G2 SYMBOL COLOR AND MATERIALS PIECES. INSTALL AS NAMES, NUMBERS, COLORS JAN 16 2008 DATE COMP NO. 1M10 1M11 1M12 1MM13 A. 1M14 1M15 1M16 1M17 1M18 1M19 1M20 1M21 1M22 1M23 1M24 1M25 1M26 1M27 1M28 1M29 1M30 1M31 1M32 1M33 -...` \\ 6 J 1 `-; \ AI R # 1 1 L'() -0 '-' — — - - SYM A B C REDRAW V 1 !!"!..T G PA [ I , 1i :IL t;AI• 2 IIND WALL (4) F -22 POWER ISLANDS REVISION SHEAR RESOLUTION 9 -50 EAST L J / 'I - 4( /'70 F;I T MDL J #760607 -01 4150602 -00 9 -101 ENHANCEMENTS (WP -2 LOBBY) J# DCA -9 -05013 ., ✓ Y 1 1 ' 1 /4. 1 1 / ^11 I n L • L - I 1 9 -!;A1' 'A,' AR II . - - `; (,AL (.(..3LL `i ^,N DI - _T, R 14 ' ( Li `f , BY K.BUN SLB M.WONG DLR GROUP FOR E,'',JST C(')i F(;TIO i..'- -.. ..)]' I L, .JCL D T -!L .. L . 1_.k'I ILLC I II2)N `: 'EM 1 4,000 ; CI M , 141 `.J1' , ARAN C)CNED IN PI :A l D A C KDRAFT LJ''`Iv9 'LI T MODEL 81 APPROVED 1 `;l /;J4 RWS /EJC RWS KAP I � 20/24 „ I • z. 4_ L!2 CO LPLri(L J DATE 6.26.97 7.8.97 08.24.05 12.16.05 ` XII : ;T1\ R #2 f ± 1 .[ }..1 r)/ CESILLL (0 2000 CI V LAC I • , 11120 SYM 1 4 '('�1 !Li\ 70000 \ z /' ('‘,FM 1 CAE' f r rVF r (Jf' :IcANI. ROI) SUFPOR'f 55/24 /5/74 PORT, ^ELE 1'1 7U( 0) / -1 REVISION 50/20 L)00 L L -OA 62/46 rt T —u 45/74 `OFF R1FINC IL) 8.�- Uv1AC -1 Fl .FX �� , ; /- 27 fl A/4 D I AN � , ' 7 N1 BY N `1 I 14/20___ • I, )I E1. 16' 30ID LL 14/20 38/24 17 (TYP) DISC SA\DER APPROVED -� ' 4 TORIT OUTSIDE © N/1 -- DATE 38/20 2x1+1)0 TO SAN 0 OOAV, H FAT I' . 011 ' L. „O0! J 1 _ if 1 I ) rj , C 4551 .3 LL N L NE FAN " NN 1()00 ( „FE I H - 4 0 v 5I-1 1 .. 1.... I r,” f ] (na 00l L:1 P'19 KING I1,JINACL, 1000 - 'FM, 2' 0 -\ /, 1 0 EIDN x'11 ) K1 WITS ■'I ? j,..__AeremsrAw m H ij x;11 I) �11 C F P,M 1' H i AHU 1 &2 SERVING 1 I1CH DAY AREA 1OCATED ABOVE 2ND I-LUOR APPROVED BY FIRST FLOOR HVAC DUCT RE SCALE: pie _ � -a ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN K. BUN CHECKED (ENGINEER C. HARRAH CHECKED RWS APPROVED E ROVED C DATE 6.26.97 6.27.97 12.19.97 12,18.97 SUBTITLE TITLE LEGE\ REVOVAL \CTES: PROVIDE TEMPORARY CAP ON DUCTWORK THIS LOCATION. REMOVE & DISCARD ALL EXISTING DUCTWORK /DIFFUSERS /ACCESSORIES FROM THIS POINT DOWNSTREAM. REMOVE & STORE EXISTING THERMOSTAT FOR FUTURE USE AT DIFFERENT LOCATION. REMOVE EXISTING UNIT HEATER & THERMOSTAT. STORE OR DISCARD PER DIRECTION OF BOEING CONSTRUCTION MANAGER. REMOVE & DISCARD EXISTING RETURN AIR GRILLE. REMOVE & DISCARD EXISTING RETURN /TRANSFER GRILLE AND DUCTWORK. a. ISSUE FOR CONSTRUCTION REMOVAL FIRST FLOOR HVAC DUCT REMOVAL PLAN MECHANICAL MASTER 9 -101 ENHANCEMENTS (WP -2 LOBBY) BUILDING 9 -101 .. al! '.!'�i' �E ' J \ERAL \OTES: 1. SEE GENERAL NOTES & ABBREVIATIONS ON SHEET G3. COL. N -S/1 -6 DEV. CENTER, W TT TT 1M34 1 M39 1M35 1M36 1M37 1 M40 1M40 1M44 1 M42 1M45 1M43 1M46 9 -101.1 KEY P__AN 1M38 SCALE: NONE SCALE: 1/8”=1' -0” 16' 08 DLR GrO Architecture Engineering Planning Interiors CURRENT REVISION J #DCA -9 -05013 SHEET JOB NO. DWG NO. SYMBOL 1M13R 15060200 9-101- M`W. DATE 12.1 6.05 COMP NO. WONnK: 8/24/2005 10:38:25 AM MATCH LINE - FOR CONTINUATION SEE 1M60 1M61 1M62 1MM63 1M64 1M65 1M66 1M67 1M68 1M69 1M70 1M71 1M72 1M73 1M74 1M75 1M76 1M77 1M78 1M79 1M80 1M81 1M82 1M83 SYM A C_J - _r r REDRAWN REVISION PUR /INSTALL MODULAR CLEAN ROOM J #546610 -01 9 -101 ENHANCEMENTS (WP -2 LOBBY) J# DCA -9 -05013 n H WH 1 , ` . . j BY KB /CH C. HARRAH DLR GROUP • 'AINDO It! :t1 01 ••, AREA Cx)} APPROVED RWS KAP J 4 coN I I J 1 1 10.01.04 HW'� H — MAf'NLJrAC TURIN (-; 6,400 F f . LRL CL 1'.(y C. 1 /4" WYE SYM I HW lJP T f _ .+ "+ --HW3 fi r ._� - SIAM #11 0' -t " N csI �� an iii w ii I i AiAAf�Illil�! PORTABLE 1 YE -WASI1 HWS IEWR REVISION iW a 1 7 C) L , BY v f .7 T —1 APPROVED DATE 6.26.96 DATE 12.16.05 — .''JI I I- {WR • H FIaT #(') i o L.. // 1 r OP, CiI, `, 55( M • CHWR - - - --- _ - - -- - i -OI IWS — -- — fIW'; HWI? 4 \ I AFMEAFAlig 1-I I E TIRES: 02/18/09 1 4 FIRST FLOCP, HVAC PIPI \G REV OVAL PLA\ SCALE: 1/8"= r_a ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED EVER CHECKED APPROVED APPROVED DATE SUBTITLE TITLE MECHANICAL MASTER ISSUE FOR CONSTRUCTION FIRST FLOOR HVAC PIPING REMOVAL PLAN 9 -101 ENHANCEMENTS (WP -2 LOBBY) BUILDING 9 -101.1 COL N -S/1 -6 LEGE\ HPC CONDENSATE STEAM (HIGH PRESSURE) HPS STEAM SUPPLY (HIGH PRESSURE 125, 250 PSIG) STM STEAM SUPPLY HWS HEATING WATER SUPPLY HWR HEATING WATER RETURN CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY COND — CONDENSATE -- P COND --- PUMPED CONDENSATE GE\ ERAL \ OTES: 1. SEE GENERAL NOTES & ABBREVIATIONS ON SHEET G3. 2. COORDINATE SHUT -DOWN OF HEATING WATER SYSTEM WITH BOEING CONSTRUCTION MANAGER. REV OVAL COTES: REMOVE NOTED SECTION OF HEATING WATER PIPING (2 "HWR, 2--1 /2 "HWS). PROVIDE TEMPORARY CAPS THIS LOCATION FOR FUTURE RECONNECTION. REMOVAL Y DEV. CENTER, WA DWG N0. 1M84 1M89 1M85 1 M90 1M86 1M91 1M94 1 M87 1M92 1M95 1 M88 1 M93 1M96 9 -101.1 KEY PAN SCALE: NONE SCALE: 1 /8 " =1' -0" ED JAN 16 2008 PER►MiT CENTER DLR Group Architecture Engineering Planning interiors CURRENT REVISION J #DCA -9 -05013 SHEET JOB NO. T TT 1 M63R 546610-01A SYMBOL B 9- 101.1 -1M63R COMP NO. 16' DATE 12.16.05 1M110 1M111 1M112i1M113 1M114 1M115 1M116 1M117 1M118 1M119 1M120 1M112" 1M122 1M123 1M124 1M125 1M126 1M127 1M12d 1M129 1M130 1M13' 1M132 1M133 SYM J K A k I iOVdf J " AIR AND VACiJUM - 000II-i--ISINIAYUP h'FA CF .;I FANKCOM - SHEAR RESOLUTION 9 -50 EAST B REMOVE CA LUBRICATOR C INSTALL SINK DRAIN LINE D INSTALL SINK i h I — F :-� 1 : L T REVISION 4150602-00 J #760607 -01 JOB NO. 719666 -00 719666 -00 • DPA h•.1 1N I { F1 t(1L, •_ • Teo -- LuLLLJ(INI; ANU HA4!IUIJLAIk FILI VA.I 'v 9 -101 ENHANCEMENTS (WP -2 LOBBY) J# DCA -9 -05013 DLR GROUP 4 LL .5,5- (J9' . � ' _J / „ A I ! u I i L_ _ (.1V CONI LHLN .w BY APPROVED DATE M.WONG RWS 08.24.05 SPR DMV DMV KAP RWS 12.16.05 RWS /EJC 05.05.97 07.06.01 11.14.01 /2" (T Y7 CUSTOMER VACUUM PUMP SYM F G U +. 1 }" VAC; , p 4 „ „A DN. ,p 4" 1, ' ti 4,. - •- - - - - -A — + 1D1 ▪ ..._._ s 4 LEAN MOVE EQUIPMENT E n 5 AI I A// VAC 1 1 LIAA A •■J / cw A • D1.IPi I 'x t\ rt DROP ((TYP. or 3)--- r 7" RA1 I. VA! .VF ARCVF DUCT 1 1 /i CAP LL REVISION E PROVIDE AIR LINE OILERS & FITTINGS RELOCATE #705 & #706 TOOLING CRIBS H PUR /INSTALL MODULAR CLEAN ROOM I INSTALL CLEANROOM VACUUM PUMP 1000814119 - l i.)LISI VAC, fp ( LL 1 - /)' 1- BLIND F1�AVGE X 1 1 /2" RISTR 1 1/4"------ BY M.WONG J #130232 -12 M.WONG J #130231 -14 C. HARRAH J #546610 -01 C. HARRAH 546610 -00 RWS - >< APPROVED RWS RWS RWS RWS RWS 1 cts DATE 08.19.03 03.23.04 04.29.04 10.01.04 02.16.05 UN 1, F'recHie Fluid Dish " 15i1I • - i i � I L'H 'r • I" AIRr cp - - TRIPLET AIR DROP PER K`i101M(; • TPIPI ET AIR DROP PR K` . 1 Q 1 MG "0 AIR, HI.K AIR DROPS, (2) " & (2 ) "m, :FE K�1i 11 1" AID, ANOVL IHL .ALL - - -• '1'10W `.I_JF'PL'r' I. 4 f y � � ' 7 C ) I • i 7 4 ( . BOE /NG " 0 H Er FIRST FLCOR 6 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT_ DATE DRAWN D. PRETARE CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 11/25/98 SUBTITLE TITLE ®� .,'''''''\''' _� ; : C C C ' r ISSUE FOR CONSTRUCTION REMOVAL FIRST FLOOR PLUMBING REMOVAL PLAN 9 -101 ENHANCEMENTS (WP -2 LOBBY) BUILDING 9 -101.1 MECHANICAL MASTER COL. N —S /1 -6 LEGE\D A CW - HW PW - IWP V RWL SAN G E\ REV ERAS 0T S • 1. SEE GENERAL NOTES & ABBREVIATIONS ON SHEET G3. 2. COORDINATE SHUT —DOWN OF DOMESTIC WATER SYSTE WITH BOEING CONSTRUCTION MANAGER. OVAL \OTES: REMOVE EXISTING SECTION OF CW PIPING AND STORE FOR RECONNECTION. PROVIDE TEMPORARY CAPS AT EACH END FOR FUTURE RECONNECTION OF CW LINE. SCALE: NONE CURRENT REVISION J #DCA -9 -05013 SHEET JOB NO. COMPRESSED AIR DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY PROCESS WATER INDUSTRIAL WASTE PUMPED VENT RAIN WATER LEADER SANITARY WASTE T 1M13 1M139 4 1M135 1M140 1M13 1M140 1M142 1M14 1 6 1M137 4 1M145 1M138 1M143 1M146 9 -101.1 KEY PLAN 8' 4' 0 4' 8' 16' SCALE: 1/8 " =1' -0" PERMIT CENTER DLR Grou Architecture Engineering Planning Interiors SYMBOL 1M113R 150602 -00 DEV. CENTER, WA DWG No. 9 - 1113R DATE 12.16.05 COMP NO. JAN 16 2008 1M10 1M11 1M12 1M13: 1M14 1M15 1M16 1M17 1M18 1M19 1M20 1M21 1M22 1M23 1M24 1M25 1M26 1M27 1M28 1M29 1M30 1M31 1M32 1M33 SYM 1 A B REDRAW / / / r / • \' . \ \ • :s.,••••'`• „-. 1 . L] 1 1, (4) F--22 POWER ISLANDS . // •••• / / / • REVISION SHEAR RESOLUTION 9-50 EAST / 1 L • / ,/ / / „ „1, / r\ , • / ••• I : I 1 • 9-101 ENHANCEMENTS (WP-2 LOBBY) J#DCA-9-05013 1 1 I h-1 2) I -J. 1 1 t J11760607–01 J#150602-00 BY SLB K. BUN M. WONG DLR GROUP APPROVED RWS/EJC RWS KAP DATE 6.26.97 7.8.97 08.24.05 12.16.05 SYM r. • ■ r 1 1 REVISION BY APPROVED 1 1 3111•1211SE197 DATE • Ft - SI I I lLA EZAW 2 3 5 FIRST FLOOR HVAC SCALE: 1/8"= —0" 6 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DUCT PLA DEPT. DATE DRAWN M.DITTMAR CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 06.27.92 SUBTITLE 9-101 ENHANCEMENTS (WP-2 LOBBY) BUILDING 9-101.1 MECHANICAL MASTER COL. N—S/1-6 TITLE GE\ 1. SEE GENERAL NOTES & ABBREVIATIONS ON SHEET G3. 2. INSULATE NEW DUCTWORK PER WASHINGTON STATE ENERGY CODE. CO ERAL \OTES: \STR..CTIO\ \CIES: CONNECT NEW 14x20 DUCT TO EXISTING THIS LOCATION. 14x20 SLOPE DN TO 14'-6" AFF, THEN TERMINATE AT WALL. INSTALL (3) 24x12 SUPPLY AIR REGISTERS (TITUS MODEL 300R OR APROVED EQUAL IN LOCATION SHOWN. GRILLES SHALL BE MOUNTED 30° OFF HORIZONTAL IN DIRECTION NOTED. TERMINATE 18"O SUPPLY DUCT AT FACE OF WALL, TIGHT AS POSSIBLE. INSTALL GRILLE SO THAT LEADING EDGE IS 4" FROM END OF DUCT. INSTALL GRILLE SO THAT TRAILING EDGE IS 6" FROM EDGE OF EXISTING COLUMN. INSTALL GRILLE SO THAT IT IS CENTERED ON REMAINING SECTION OF DUCT. 8> INSTALL NEW RETURN AIR TRANSFER DUCT AS HIGH AS POSSIBLE ABOVE PERFORATED METAL CEI LNG PANEL. SIZE AS NOTED. PROVIDE 18x10 SCREENED OPENING IN (2) PLACES IN LOCATIONS NOTED. 1> TERMINATE 20x18 TRANSFER DUCT AT LOCATION SHOWN. INSTALL EXISTING THERMOSTAT AT LOCATION SHOWN, 48" AFF. CONNECT CONTROL WIRING TO EXISTING COIL. ROUTE 18"0 THRU WALL AS HIGH AS POSSIBLE BELOW EXISTING BEAM — APPROX. 13'-10" AFF. ISSUE FOR CONSTRUCTION FIRST FLOOR HVAC DUCT PLAN LEGE\ DEV. CENTER, WA TT TT 1M44 1 M45 1M43 1 M46 1M34 1M35 1M37 9 -1 01 .1 KEY PLAN SCALE: NONE 8' F SCALE: 1/8"=1' —0" CURRENT REVISION J#DCA-9 —05013 SHEET JOB NO. DWG NO. 1M13 SYMBOL 1M38 15060200 9-1O1--1M13 DATE COMP NO, 16' JAN 1 6 2008 DLR G PERAT CENTER Architecture Engineering Planning Interioi 12.16.6:). 1M60 1M66 1M62 i1M63: 1M64 1M65 1M66 1M67 1M68 1M69 1M70 1M71 1M72 1M73 1M74 1M75 1M76 1M77 1M78 1M79 1M80 1M81 1M82 1M83 SYM — REDRAW REVISION A PUR /INSTALL MODULAR CLEAN ROOM 1 11 PEN' E BY KB /CH J#546610 -01 C.HARRAH B 9 -101 ENHANCEMENTS (WP -2 LOBBY) J #DCA -9 -05013 DLR GROUP J.. �. • � ,\\ \ \ \\ . - -- 14 \AIR - ---- Vii-+•- - r f } APPROVED RWS KAP J4., { f I W.; H'N H .- { { . H W 1 1 `HWH ti DATE 6.26.96 10.01.04 12.16.05 SYM HWFr' • . r E:i IIRI� • 4 - REVISION rr• � a I IVJS - ... - - HWR BY APPROVED HWH DATE H il OE /NG �r FIRST FLOOR II VAC PIPI \G SCALE: 1/8"— 1' -0" ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M.DITTMAR CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 06.27.92 TITLE MECHANICAL MASTER 9-101 ENHANCEMENTS (WP -2 LOBBY) BUILDING 9 -101.1 COL. N— S/1- -6 LL; \ D: ISSUE FOR CONSTRUCTION SUBTITLE FIRST FLOOR HVAC PIPING PLAN HPC CONDENSATE STEAM (HIGH PRESSURE) HPS STEAM SUPPLY (HIGH PRESSURE 125, 250 PSIG) STM STEAM SUPPLY HWS HEATING WATER SUPPLY HWR HEATING WATER RETURN CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY COND CONDENSATE P COND— PUMPED CONDENSATE CE \ERAL \OTES: 1. SEE GENERAL NOTES & ABBREVIATIONS ON SHEET G3. CO\ SIR Li CTIC\ \OTES NEW TO EXISTING POINT OF CONNECTION. PROVIDE NEW 2 "HWR & 2 -1/2 "HWS PIPING AS NOTED. INSTALL ABOVE NEW METAL CEILING PANELS AS HIGH AS POSSIBLE. PIPES UP /DN TO MATCH EXISTING ELEVATIONS. DWG NO. DEV. CENTER, WA. 1M84 1 M89 1M85 1M90 1 M86 1M90 1M94 1M87 1M92 1M95 1M88 1M93 1M96 9 -101.1 KEY P SCALE: NONE 8' 4' SCALE: 1/8"=1'-0" CURRENT REVISION J #DCA -9 -05013 TT T? 0 4' JAN 8' JAN 16 2008 PEE ►iyls e UL TEl DLR G rou Architecture Engineering Planning Interiors SYMBOL B SHEET 1 M63 JOB NO. 546610-01A DATE 9- 101 -1M63 16' 12.16.05 COMP NO. C ' . 1 L� Lei • 74 "X74" Li 1 • F i t K i c-}-)!1: T '` 1M110 1M111 1M1121M113 1M114 1M115 1M116 1M117 1M11E 1M119 1M120 1M121 1M122 1M123 1M124 1M125 1M126 1M127 1M123 1M129 1M130 1M13' 1M132 1M131 SYM J K B C D 4 } _ j —A d\ -r X2+ L : i ra • i 1 REVISION SHEAR RESOLUTION 9-50 EAST J #150602 -00 9 -101 ENHANCEMENTS (WP -2 LOBBY) J #DCA -9 -05013 REMOVE CA LUBRICATOR INSTAL SINK DRAIN LINE INSTALL SINK J #760607 -01 J #719666 -00 719666 --00 BY M.WONG DLR GROUP SPR DMV DMV A\ • ..A . APPROVED RWS KAP RWS /EJC RWS DATE • r x CLN A. SYM E F G H A N + P A .:4'w • A— A REVISION - • 1 PROVIDE AIR LINE OILERS & FITTINGS RELOCATE #705 & #706 TOOLING CRIBS T A v W () ♦4 —A 4) 1000814119 J #130232 -12 LEAN MOVE EQUIPMENT PUR /INSTALL MODULAR CLEAN ROOM INSTALL CLEANROOM VACUUM PUMP 4130231 -14 J #546610 -01 546610 -00 BY M.WONG M.WONG C.HARRAH C. HARRAH RWS APPROVED RWS RWS RWS RWS RWS DATE 08.19.03 03.23.04 08.24.05 12.16.05 05.05.97 07.06.01 11.14.01 04.29.04 10.01.04 02.16.05 r fl i H H H FIRST FLOOR PLUVBI \G PLA SCALE: 1/8"= 1' -0" ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M.DITTMAR CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 06.27.92 L J A CW HW - PW - IWP V RWL - SAN E\ 1. SEE GENERAL NOTES & ABBREVIATIONS ON SHEET G3. 2. INSULATE NEW PIPING PER WASHINGTON STATE ENERGY CODE. CO\STR.,CTI ERAL \CITES: 0\ COTES: PROVIDE A 24" MAX. LONG SECTION OF NEW 2" CW PIPING THIS LOCATION. ROUTE SALVAGED CW PIPING AS HIGH AS POSSIBLE ABOVE METAL CEILING PANEL, THEN TURN DN TO NEW CONNECTION. SAME AS NOTE 1 EXCEPT HOLD NEW SECTION OF PIPE AS TIGHT TO THIS WALL AS POSSIBLE. ROUTE SALVAGED 2" CW AS HIGH AS POSSIBLE ABOVE NEW CEILING PANELS. NEW TO EXISTING POINT OF CONNECTION. ISSUE FOR CONSTRUCTION SUBTITLE TITLE MECHANICAL MASTER FIRST FLOOR PLUMBING PLAN 9 -101 ENHANCEMENTS (WP -2 LOBBY) BUILDING 9 -101.1 COL. N -S /1 -6 DEV. CENTER, WA. COMPRESSED AIR DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY PROCESS WATER INDUSTRIAL WASTE PUMPED VENT RAIN WATER LEADER SANITARY WASTE SHEET DWG NO. 1M13 1M139 4 1M135 1M140 1M13 1M14 1M 141- 1M145 1M137 1M138 1 M 142 1M143 1M146 SCALE: 1/8"=1'- CURRENT REVISION J #DCA -9 -05013 PERMIT CENTER DLR Group Architecture Engineering Planning Interiors SYMBOL 1M113 JOB NO. 150602 -00 DATE 9- 101 -1M113 COMP NO. 6' JAN 1 6 2008 12.16.05