Loading...
HomeMy WebLinkAboutPermit M07-231 - WESTFIELD SOUTHCENTER MALL - JOEY'S GRILLJOEY'S GRILL 758 SOUTHCENTER MALL M07 -231 Parcel No.: Address: Suite No: City.A Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 758 SOUTHCENTER MALL TUKW Tenant: Name: JOEY'S GRILL Address: 758 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: Address: PEGGY PEEL 4600 S 134 PL , SEATTLE WA Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA Contractor License No: HOLADPI379NO DESCRIPTION OF WORK: INSTALL (5) A/C UNITS, (4) EXHAUST FANS, (6) HEATERS AND (4) VENTS. MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: REVISION NO 1: ADD (4) HOODS (NO PLANS ACCOMPANY THIS REVISION - HOODS ON ORIGINALLY APPROVED PLANS) Value of Mechanical: 406,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial EOUIPMENT TYPE AND OUANTITY 0 0 0 6 4 0 0 0 0 0 4 0 0 0 * *continued on next page ** Phone: Phone: 206 248 -8747 Phone: 206 248 -9700 Expiration Date: 09/03/2009 M07 -231 12/18/2007 06/15/2008 Fees Collected: $3,592.18 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP/100,000 BTU 0 3-15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 5 doc: IMC -10/06 M07 -231 Printed: 03 - 13 - 2008 Permit Center Authorized Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -231 Issue Date: 12/18/2007 Permit Expires On: 06/15/2008 Date: 07, (79` I hereby certify that I have read and xarined this permit and know the same to be true and correct. All provisions of law and ordinance: governing this work will be complie v:n , whether specified herein or not. The granting of this permit do construction or the perfo Signature: Print Name: doc: IMC rity to violate or cancel the provisions of any other state or local laws regulatinc d to sign and obtain this mechanical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 -231 Printed: 03 -13 -2008 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: City f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 758 SOUTHCENTER MALL TUKW JOEY'S GRILL 758 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: PEGGY PEEL Address: 4600 S 134 PL , SEATTLE WA Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA Contractor License No: HOLADPI379NO MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL (5) A/C UNITS, (4) EXHAUST FANS, (6) HEATERS AND (4) VENTS. Value of Mechanical: 400,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial EOUIPMENT TYPE AND OUANTITY 0 0 0 6 4 0 0 0 0 0 4 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 248 -8747 Phone: 206 248 -9700 Expiration Date: 09/03/2009 M07 -231 12/18/2007 06/15/2008 Fees Collected: $3,544.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP/100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 5 doc: IMC - 10/06 M07 -231 Printed: 12 -18 -2007 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and Imow the same to be true and correct. All provisions of law and ordinance, governing this work will be complied with, whether specified herein or not. The grantin construction Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Ci) presume t ork. I rc( r Permit Number: M07 -231 Issue Date: 12/18/2007 Permit Expires On: 06/15/2008 q 4a Date: 1)- -t Tl — 0 7 ve authority to violate or cancel the provisions of any other state or local laws regulating orized to sign and obtain this mechanical permit. Date: (a. ° v / This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 -231 Printed: 12 -18 -2007 Parcel No.: 6364200010 Address: 758 SOUTHCENTER MALL TUKW Suite No: Tenant: JOEY'S GRILL 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 - 231 Status: ISSUED Applied Date: 10/30/2007 Issue Date: 12/18/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) doc: Cond -10/06 M07 -231 Printed: 12 -18 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 20: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 21: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 22: Local U.L. central station supervision is required. (City Ordinance #2051) 23: All new automatic fire- extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 24: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 25: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 min) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 26: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 27: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 28: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M07 -231 Printed: 12 -18 -2007 I hereby certify that I have this work will be complied The granting of this permit construction o - perfo Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us read these conditions and will comply with them as outlined. All provisions of law and ordinances governing with, whether specified herein or not. does not presume to give authority to violate or cancel the provision of any other work or local laws regulating ce o work. Date: 7) �l O CJ 7 M07 -231 Printed: 12 -18 -2007 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: Company Name: Property Owners Name: Mailing Address: CONTACT PERSON - who do we contact when your permit is ready to be issued Name: v5 . Gvo Mailing Address: ii4ee • /,3 "1 w e, � E -Mail Address: p Q 9 y 9 &A a A dal / a r i" _ C.O en GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Ge .. . /314 Qt./L44-1L 11)/ -. 98/611 /� /—e_o-756e-c,,eity State Zip Contact Person: � 14f - G e ° , Day Telephone: :Q 4 - s2 4 / e - 8 717 E -Mail Address: r 75 yie p / ec d a y ,pd r l S . CAD vs. Fax Number: .2 0 to - ..2 f- S' 7.60 /1 Contractor Registration Number: )LA cl) PS .3 794/0 Expiration Date: / VD 7 Mailing Address: 44 0 0 City City Fax Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Building Peo. Mechanical Permit No. Plumbing/Gas Permlt Public Works Permit �No. Project No. FO 1 (For office use only) King Co Assessor's Tax No.: .-1/4 - i9e Suite Number: Floor: New Tenant: pr Yes ❑ .. No State Day Telephone: 6 4 - - g 717 wig 9Y /6 8 State Zip cs2 D ttt► -.4445` -8700 Company Name: Mailing Address: Contact Person: E -Mail Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: Q:Wpplications `.Forms - Applications On Line a -2006 - Permit Application.doc Revised: 9 - 2006 bh City Day Telephone: Fax Number: State City Day Telephone: Fax Number: State Zip Zip Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Mount ed d Heater er IUFloor Mounted 4 Ventilation System , / Wood/Gas Stove 30 -50 HP /1,750,000 BTU Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to HeatlRefrig/Cooling System Incinerator - Domestic Other Mechanical Equipment A /L! .& Air Handling Unit <10,000 CFM Incinerator — Comtn/Ind / ( /0 , ciao CF»1 MECHANICAL PERMIT INFL ATION — 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: a .y cRQ.t46¢. ut Mailing Address: l/ D0 S -OO /31 /31 Contact Person: I ,/ E -Mail Address: P�qG v (�v /t p /aclorpa r/FS • C,o r+-.. Contractor Registration Number: i5/o L A1) Ps 3 7 9 A Valuation of Mechanical work (contractor's bid price): $ 00 D. Scope f Work (please provide detailed information): -.� () ,u.. Use: Residential: New .... ❑ Commercial: New .... ❑ Replacement .... ❑ Replacement .... ❑ City Day Telephone: Fax Number: Expiration Date: ' State Zip c.7 .?18 -87$ - e? VC -2 7 Ves tcI,* ?g/‘g Fuel Type: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: Q:\Applications \Forms - Applications On LineO -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OyV OR AUTHORIZ D C75 rr P • VO Telly L P/ Mailing Address: 4 oo S . / 31 — j Signature: Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Date Application Accepted: Q:Wpplications \Forms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date Application Expires: Date: / z9 /o 7 Day Telephone: of a G - ,2 g . g 74 7 lv4- 98/44 City State Zip Staff Initials: Page 6 of 6 Parcel No.: 6364200010 Address: 758 SOUTHCENTER MALL TUKW Suite No: Applicant: JOEY'S GRILL Receipt No.: R08 -00743 Initials: JEM User ID: 1165 Payee: HOLADAY- PARKS, INC. TRANSACTION LIST: Type Method Payment Check City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Descriptio 164655 ACCOUNT ITEM LIST: Description Account Code MECHANICAL - NONRES 000/322.100 PLAN CHECK - NONRES 000/345.830 RECEIPT Amount 47.93 Permit Number: Status: Applied Date: Issue Date: Payment Amount: $47.93 Payment Date: 03/13/2008 11:39 AM Balance: 80.00 Current Pmts 38.34 9.59 Total: $47.93 M07 -231 ISSUED 10/30/2007 12/18/2007 9880 03/13 , 7.710 TOTAL 47.93 doc: Receiot -06 Printed: 03 -13 -2008 Receipt No.: R07 -02780 Payee: HOLADAY PARKS ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M07 -231 Address: 758 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/30/2007 Applicant: JOEY'S GRILL Issue Date: Initials: WER Payment Date: 12/18/2007 09:30 AM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 163385 2,841.40 Account Code Current Pmts 000/322.100 2,841.40 Total: $2,841.40 Payment .Amount: $2,841.40 6215 12/18 9710 TOTAL 2841.40 doc: Receipt-06 Printed: 12- 18-2007 Receipt No.: R07 -02367 Payee: HOLADAY- PARKS, INC. ACCOUNT ITEM LIST: Description dnn: Rareint -OR PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: M07 -231 Address: 633 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 10/30/2007 Applicant: JOEY'S RESTAURANT Issue Date: Initials: JEM Payment Date: 10/30/2007 03:17 PM User ID: 1165 Balance: $2,841.40 TRANSACTION LIST: Type Method Description Amount Payment Check 162350 702.85 Account Code Current Pmts 000/345.830 702.85 Total: $702.85 Payment Amount: 5702.85 Printad. 10 -n0 -2007 Project: 39 6-,r(( Type of Inspection: Na F.' iv, t Address: off N4<( Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: 13 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 t107-027( PERMIT NO. (206)431 -3670 COMMENTS: CO rr'cf fv'S C'o- ^ Approved per applicable codes. ❑ Corrections required prior to approval. (Inspector: 2 (Date: 1 3 - sv rl $60.00 I EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: 1. ( It-// St r oc c reN elio-kerg 5 ,.4 rl)r)+TO P rut b 2. Se4Lk.rc c o4ele e,. iv «r b 3. C ovet SrNBh'e sAu7 iCc'h ////k7(-e �� // < Date Called: _.._ Special Instructions: Date Wanted: �/ 7 / cob a.rr p.m. Requester: Project . Cron / I Type of Inspection: / ; h r v C ,S Address: 7.-R �� // < Date Called: _.._ Special Instructions: Date Wanted: �/ 7 / cob a.rr p.m. Requester: Phone No: 2 8'5 // Y3 12 INSPECTION RECORD . Retain a copy with permit IV07-)-3/ INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. El Corrections required prior to approval. (Inspector: (Date: / g ri $60.0 E(NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid a 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: 1 COMMENTS: 0 /241.4'ir. C ;IV r z--7 b,--/<,( 7 /v' / -LA Lis -- 7 /,j; - 1 / 01 iI- J r3 A/ (A/170 / V L' S /7, el PO - .. s .. ) o/ze-/t,vr 1 vfQ 1-44 -e /5 1 4 i''s ss PeOe5 n 7J 1-ef- Date Wanted: ( -2 t� 7_,,W%-*//t".• /4 A?,pervYc, C' /� /- v 5 --. /(/ 17 c - ' J 00 Y ��_ 777 J \ Proje %`� �r� / / Type of Inspection.: z & Address: _ ,9// Date Called: Sp Instructions: Date Wanted: ( -2 t� a.m p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 El Approved per applicable codes. orrections required prior to approval. • nspe •r: > 7 1 Dat 2 C - obi 0.00 REINSPECTIOI FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcen er Blvd , Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: —�� 1 3 Type of Inspection: £h I64St �a y Address: filed/ Date Called: f _.,--.. Special Instructions: Date Wanted ,f � p.m. , g Requester: Phone No: 2.0C 1 3 r5 - 3 INSPECTION RECORD Retain a copy with permit lD7' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ?- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3¢7 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: CA-4Nee_it<4 'Inspector: 'Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: !Date: Project: Type of Inspection: - )1/04 5/1/1 /.t tit) Addres . Date Date Called: Special Instructions: Date Wanted: G 5 —OP a.m p. • Requester: Phone No: INSPECTION RECORD �n,,�t { Retain a copy with permit M t--2 INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 i y.Approved per applicable codes. Corrections required prior to approval. COMMENTS: Srii/) k5 ,5 )tr joNo ' Ifs ✓��t is0 pect • : rf441 ❑ :11, pathy .1 / n' - 7 --C 0 REINSPECTION�FEE REQUJ�RED. Prior to inspection, fee must be at 6300 Southcent r Blvd., Mite 100. Call to schedule reinspection. I Rec: t No.: 'Date: Project: 0 _5 7 /'/ . / i Type oljnspection*—__ _ Z.)?/ ff —1---AL5 A ress: i qate - 7 5 e sih, -A(' Ailer CrIled: 4 / Special Instructions: Date WIn ted: P-M• Requester: Phone No: 406.-,..S.Szi—//8 3 INSPECTION RECORD INS7PE ION NO. PERMIT NO. Retain a copy with permit / 11172 3 / CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 '' proved per applicable codes. Corrections required prior to approval. COMMENTS: e / poo__/1_477e/pfr,./(0 9, Nit°4---LAI (4), i k, I 6 REINSPECTION E REQUIR. E Prior to inspection. fee must be 1/ . at 6300 Southcente Blvd.. Suit 100. Call the schedule reinspection. 'Date: \,) Pr o C\` �S rp r ` (' Type Innplctioh - / ki Address e / vi 4 I( Date Called: Special Instructions: Date (/ 68 ( •m p.m. Request r: Phone No: Ct!= /V INSPECTION RECORD c Retain a copy with permit INSPE PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: P/ Inspector* Dat / ! /p 0 ?. REINSI CTION FEE EQUI D. Prior to inspection, fee must be a at 6300 Southcenter Bl , S e 100. Call the schedule reinspection. 1 Rec pt No.: (Date: COMMENTS: A n / ow/ Type nspection: ei_ i Ats _ 0 6 ,-,45 - M'o Mize ,/ A v 0 Ad drres / - 1—� --- 'Vki /�' � / 0 7l? _ vs'z.C/r/f, Special Instructions: Date!7tel , ! L / 1 0 /gym C p' / R,../.104- / - vF„ /; - ,97. �,(sa- o .3 v 4-) I` / j L' /e t) (c)rrner Phone No: r Proje ] , ,, Ci�S c `�. / �� Type nspection: ei_ i Ats _ Ad drres / - 1—� --- 'Vki /�' � / 0 Date Called: Special Instructions: Date!7tel , ! L / 1 0 /gym C p' / Requester: Phone No: 7 /M7- -23 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes (Corrections required prior to approval. 1 Rec pt No.: ti Date:, '/"�7 O G 1 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspecton. 'Date: COMMENTS: (i) 4 C� ieSi /d"'k, 4 / - //,' r. ID7/f- 44/Rf/P .. / l e // r/eve gerlh.fAiim l e4,,v • (-4.7 _...) L /3 ww-r ..2,n4 (, o / 3 (A'9 /li, - " /&g.f fj /1/V a -vf' 6- ( /6,1t 7 A / 0 - 7 - � 4/t , "i4p /��� j ,-7r/p ' / v V ,3ir,J/,,i'1 t/ zi„t C 14, .07 1/1/tS4 �)• ) -I c? v (# 1 •■ ' . Phone : -9 Z7 Project: 1 ' Type of Inspection: r� ..4 - / v Address: Date Called: Special Instructions: Date Wanted: 1 " 2 — •OV °a.m2) p.m. Requester: Phone : -9 Z7 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. El Corrections required prior to approval. Inspector: (Rec •ai. t No.: INSPECTION RECORD Retain a copy with permit ril0 Z 31 PERMIT NO. Date: !Date: Z - c9g. REINSPECTION FEE REQUIRED.,Prior to inspection. fee must be t 6300 Southcenter Blvd.. Suite 1 0. Call the schedule reinspection. Pro• t: Type pf Inspection: Address: jflt// Date Called: Special Instructions: Date Wanted: a.m ✓ - I - f— p.m. Requester: Phone No w 4 - 8,s y - // 8 3 Y INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 E1 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ,Q7,J, el( 16-" ST, Jco,f 4 -A4i /1/?IWd0 In •ect 44 / � ` I Dat> 0 qf 00 REINSPECTION E REQVRED. Prior to inspection. fee must be aid at 6300 Southcenter lvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project c9 ( -/ (t Typ f Inspection:, 6 r ) h - / k) Address: lei M 7S ce///"F•t l/ Date Called: S eciaTTnstructions: P Date Wante 3 /26/ag p.m. Requester: Phone N Phone : y- 118 5 INSPECTION NO. INSPECTION RECORD Retain a copy with permit ,9D 723 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ? 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Ei Approved per applicable codes. E1 Corrections required prior to approval. COMMENTS: ,Q - 1' T a . ,vr 1) 7 /e--74- o /C Tv TA.J5?f 'r pector tim IDa3 J2 /o4 REINSPECT ON FE REQUIR Prior to inspection, fee must 3t at 6300 Southcenter lvd., Suit 100. Call the schedule reinspection. 'Receipt No.: 'Date: Proj / Of y. l / Type I nsp e tiofl ,a r (1 -Zrusit t1X L Ad ess: / y 766 C, 'd7f At l" », P/ Date Called: Special Instructions: Dat anted: �� / 4. J!7 �: P.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit /71 6 7-23/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IF' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ,Z)2 i /./- k/ -- /12/ /23 2 Ael pector: I Recei • t No.: A Cif EINSPECTION FEE RE IRED. 5' ' nor to inspection. fee must be t 6300 Southcenter Blvd.; uite 100. Call the schedule reinspection. I Date: COMMENTS: 4 ,44.,friNmu-1 / Nf' /7.iCl ,� / ��l / % t/f 2 / 4L 4 S of 4 A�w /../+�✓ / /� is--4,..7 /$ • * /#s!/1 TO j Ai /( 17 601A 10 )'4"411 -+ Date Wanted: . Igi 2-7,i- 7 . fi1t.C/ / 7 / 01 y9 / z i r� Z ?ie /741/0 "7 J i// - r' 4 c4 / 4- iA} / 7 /NS?/ 4 ) Z,C - /"- ,, // 1,' / /.S I/ 44 /4 /.t1SQil✓O44rU. //Y) /.G/t� claw */ 2 - /4r- P1 i�j/7 .v,� �sy -^1 4 ‘A.--4,7 L Project: � G� /i� n Type lnspecti : , �/ - / v Address: ---7J 5O /141 "/ , 7ed 1, Special Instructions: _ Date Wanted: . —/� oh m' Requester: Phone No: ` .0 6 -I /8 I INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. nspect !4."."" .00 REINSPECTION FI paid at 6300 Southcenter 'Receipt No.: PERMIT NO. a Corrections required prior to approval. I Date: 3 - 7o — ` 6 E REQUIgE Prior to inspection. fee must be B lvd.. Syfite 100. Call the schedule reinspection. 'Date: COMMENTS: Sprinklers: r li j14_8Q,° e .I r /t �r .• f _ ,. 1 , Monitor: ; Address: -7 5 c Suite #: c 6: i n,14- . •4_-- d< - i ri 54 ' / 1 Special Instructions: ,; Phone No.: Project: Sprinklers: Type of Inspection: Hood & Duct: Monitor: ; Address: -7 5 c Suite #: c 6: i n,14- . •4_-- Contact'Persoh: f 01r- ,1, ' / 1 Special Instructions: ,; Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 206 - 575 -4407 5 Z Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS ri Corrections required prior to approval. Inspector: Date: Hrs.: vj it/ khe $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 y Project: .... I ,� ,�3 e. ` s . t 1 Type of Inspction: A / 441_ 3oo ry , Address: � Contact Pdrson: i Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: ' Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 206 - 575 -4407 2 - Appfoved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS n Corrections required prior to approval. COMMENTS: Date: /i 'kg ' Hrs.. a �� $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from t he City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 April 8, 2008 Shay Sabour 12645 NE 140 St Kirkland WA 98034 RE: Request for Extension #2 Development Permit No. D06 -392 Mechanical Permit No. M06 -231 Plumbing/Gas Piping Permit No. PG07 -003 Pacific Court Bldg A — 4028 S 146 St Dear Mr. Sabour, This letter is in response to your written request for an extension to Permit Nos. D06 -392, M06- 231, and PG07 -003. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending the expiration date of your permits an additional 180 days, through October 3, 2008. Please also note that there is a revision which provided footing and deck details that needs to be picked up. There are no fees owing for this revision, but this paperwork must be out in the field for the inspectors prior to final inspection. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, fifer Marshall it Technician City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director File: Permit No. D06 -392, M06 -231, PG07 -003 P:\Pemit Center?Extension Letters \Pemrits\2006\D06 -392+ Permit Extension #2.doc Page 1 of 1 jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 COM.MUNTY Go 0 R. DEvELDPKENT ig4 s. AY:TY i 5 ._41 - 4 lia (71;75 frok,./._ g :s is Cc c.t.) 10,14e,.. Ve l Wa-% .As\ /kJ e Xlevi lit)." 0 „„ p •C I r "I 7 1,-e„,.-- . P-e. 4-‘") r/ f‘lo-2-3D_ /1 L . 2 3 i JtK jc) , tc p &c: ,-- i ., 0. , itgo - 1 • i 0 . , P Go- f., - i .....o ti , , 0 4/1 77 k v7 D 0 t, - 313v tat- cwt.- o; pG ...1.,-1,,c1, EiLoef ,,,,,..,d_ v,,e,„ hj iv- A (I., tilt 1 ....., ru-ir 2. f"-.. .-1 - -y a,....Z cJ (4-:)c, REOEIVED tilAR g 1 OIS • 64e 6, 17 101072in November 15, 2007 Peggy Peel 4600 S 134 P1 Seattle WA 98168 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M07 -231 Joey's Restaurant — xxx Southcenter Mall Dear Ms. Peel, City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenzer service. If you have any questions, please contact me at (206) 431 -3670. Sincerel - ROAft10 — Bill Rambo Permit Technician encl xc: File No. M07 -231 P:\Perntit Center\Correction Letters\2007\M07 -231 Correction Ltr 111.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -366J, Building Division Review Memo Date: November 13, 2007 Project Name: Joey's Restaurant Permit #: M07 -231 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 1 1x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Sheet M2.01 is difficult to read. Additional drawings shall be required to separate out the different mechanical systems for clarity. In addition many of the key references are not identified in the front page legends. In particular are the large black lines showing a diamond box with the letter "S "? Please revise plans to show clarity and where all symbols are identified in the legends. 2. The fire place vents show long horizontal runs of `B" vent. Provide manufactured specifications, UL listing and install information for the fireplace venting including the terminal vent vans for the fireplace ventilation system. The horizontal "B" vent shall not be allowed without a designed ventilation system at the termination of the vent system supplied with an automatic shutoff (a listed manufactured design). The intent is to not allow carbon monoxide fumes to fill the building should the exhaust fan fail and where the potential of fumes leaking from the seams of the `B" vent would create a hazard. (IMC Section 804 & specifically 804.3.8) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: M07 -231 DATE: 11 -30 -07 PROJECT NAME: JOEY'S RESTAURANT SITE ADDRESS: 758 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: c Buildi i g ' ivision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents routing slip.doc 2 -28 -02 PERMIT COORD COPY"' PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ DATE: DATE: Planning Division ❑ Permit Coordinator DUE DATE: 12-04-07 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 01 -01 -08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY"' PLAN REVIEW /ROUTING SLIP ACTIVITY NUMB M07 - DATE: 10 -30 -07 PROJECT NAME: JOEY'S RESTAURANT SITE ADDRESS: XXX SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # DEPARTMENTS: I i Bu j n g l I ior Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 Response to Correction Letter # Fire Prevention Structural ❑ Incomplete n TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: E Revision # After Permit Issued DATE: DATE: Planning Division Permit Coordinator No further Review Required Approved with Conditions ❑ Not Approved (attach comments) DUE DATE: 11 -01 -07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 11-29-07 Permit Center Use Only { [� `� CORRECTION LETTER MAILED: I I -1 J -01 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: '1l�/� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: i4.210? Plan Check/Permit Number: / f 7-,2 2 3 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # f after Permit is Issued El- requested by a City Building Inspector or Plans Examiner Project Name: Project Address: 75 Contact Person: Summary of Revision: Steven M. Mullet, Mayor Steve Lancaster, Director rrr aECEivEp L4 MAR 13 2008 ~EkMI r cENTEh Phone Number: g : 7 1 4 1 6 "a T g' ' 7' 7 (J -/ � . „ „dg . Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: tk r- Entered in Permits Plus on \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: City of Tukwila Date: iI /2 7/ o 7 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Received at the City of Tukwila Perm Center rbby: Entered in Permits Plus on 11 1 " \applications\fomu- applications on line\revision submittal Created: 8 -13 -2004 • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us EAU S {1�Sa F rr1 rsou `y�5€�y; t %tR_7lld`.' C lY .l'Ai• t' ° .'fw 0441 41('41 4 144:-1!: L iY .iy?ee. Ye'rt —. i1 i � t1.i .i) S Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M07-231 Steven M. Mullet, Mayor Steve Lancaster, Director At e CCTV n- NOV 3 0 2007 r'EFitoir CENTER Project Name: Joey's Restaurant Project Address: XXX Southcenter Mall Contact Person: Peggy Peel Phone Number: Summary of Revision: ru.spens # 1 • Pro y � desk r►1 � s5 � ►`` e ds N. � fv�re.vtec r� duceJ 1 •,bl w ITif I l t*r iwckcl rvu r.4y 5v +1 fire, duds a iJ a c a sor w1 N be- c(care r. Ase Nye- * Z. +J jJ -vtoft -�r✓ �- Ve wt GAty) u ST) in M a.b l &&p 3 �a � � calf *&t It be UL. [rsted �lid �� . �r►std�r _ 2 freac2- Y4r% i Fr 010"15 . ire ptow McckuvI; Cc ( cQ r S./ 5.1-011 mply 01 # I C. (ADO Oct Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisio 1 i t I License Information License HOLADPI379NO Licensee Name HOLADAY PARKS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 578004089 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 69208 Address 2 City SEATTLE County KING State WA Zip 98188 Phone 2062489700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/21/1983 Expiration Date 9/3/2009 Suspend Date Separation Date Parent Company Previous License HOLADPF376NO Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD T JR 01/01/1980 PARKS, DAVID L 01/01/1980 TALBOT, PAUL 01/01/1980 NELSON, MICHAEL 01/01/1980 BECK, DAVE 01/01/1980 OCONNOR, BONNY K 01/01/1980 NAILON, JUNE A 01/01/1980 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HOLADPI379NO 12/18/2007 GENERAL NOTES 1. ALL TRADES TO LEAVE 36" CLEARANCE IN FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 2. CUTTING, FRAMING, PATCHING AND PAINTING OF WALL, CEILING AND FLOOR OPENINGS SHALL BE BY GENERAL CONTRACTOR. 3. ROOF CURBS, FLASHINGS, SLEEPERS, PITCH POCKETS, AND CUTTING AND PATCHING OF ROOF OPENINGS SHALL BE BY GENERAL CONTRACTOR. 4. ROOF CURBS, SLEEPERS, AND CANT STRIPS TO BE BUILT AND FASTENED TO THE ROOF BY GENERAL CONTRACTOR. CURBS TO BE CONSTRUCTED ACCORDING TO SIZES PROVIDED BY HOLADAY- PARKS' FIELD MECHANIC. SHIM AS REQUIRED TO MAKE ROOF CURBS AND SLEEPERS LEVEL TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. MAXIMUM ALLOWABLE DEVIATION FROM LEVEL OR FLAT SHALL BE 1/4. IN 10'. ROOF CURBS AND SLEEPERS MUST BE SECURELY FASTENED TO STRUCTURAL SUPPORT MEMBERS. 5. FINAL PAINTING OF GRILLES, REGISTERS, AND DIFFUSERS, AS MAY BE REQUIRED BY ARCHITECT, SHALL BE DONE BY GENERAL CONTRACTOR. 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DURING CONSTRUCTION. 7. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COORDINATED WITH ARCHITECT AND STRUCTURAL ENGINEER TO DETERMINE BUILDING STRUCTURAL ADEQUACY. IF IT IS NECESSARY TO RELOCATE A UNIT, NOTIFY HOLADAY- PARKS' ENGINEERING DEPARTMENT FOR RE- COORDINATION. 8. ALL EQUIPMENT AND PIPING WHICH IS SUSPENDED FROM ROOF SHALL BE SUSPENDED FROM GLU -LAMS WHERE PRACTICAL, OR FROM TRUSSES. DO NOT SUSPEND FROM STIFFENERS. FOLLOW TRUSS MANUFACTURER'S REQUIREMENTS WHEN ATTACHING HANGERS TO TRUSSES 9. IN NO INSTANCE SHALL OTHER TRADES HANG OR SUPPORT EQUIPMENT, CEWNG WIRES, LIGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT OR DUCTWORK. 10. PLUMBER SHALL ROUTE PLUMBING VENTS SO AS TO MAINTAIN MINIMUM 15 FEET OF CLEARANCE FROM OUTSIDE AIR INTAKES. 11. ALL HVAC AND PLUMBING EQUIPMENT ON THE ROOF SHALL LABELED WITH TENANT NAME (JOEY) AND SUITE NUMBER. 12. PROVIDE TENANT WITH COPIES OF SERVICE REPORTS FOR GREASE DUCT MAINTENANCE AND GREASE MITIGATION ON ROOF AROUND GREASE EXHAUST HADNDLING EQUIPMENT. ELECTRICAL COORDINATION NOTES 1. WHERE INDICATED ON EQUIPMENT SCHEDULES, THE EQUIPMENT COMES COMPLETE FROM THE FACTORY WITH MOTOR CONTROLS AS REQUIRED. ELECTRICIAN SHALL PROVIDE SERVICE AND A DISCONNECT PER CODE, AND DO ALL POWER WIRING, INCLUDING CONNECTING TO EQUIPMENT. 2. WHERE INDICATED ON EQUIPMENT SCHEDULES, THE EQUIPMENT REQUIRES FIELD INSTALLED MOTOR STARTERS. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL MOTOR STARTERS (OR CONTACTORS WHERE INDICATED), PROVIDE SERVICE AND DISCONNECT PER CODE, AND DO ALL POWER WIRING, INCLUDING CONNECTING TO EQUIPMENT. HOLDING COIL CIRCUIT SHALL BE POWERED BY ELECTRICAL CONTRACTOR (120 VOLT /1 PH. UNLESS INDICATED OTHERWISE). ALL STARTERS SHALL BE PROVIDED WITH H -O -A SWITCH. 3. 2 - 120V CONTROL CIRCUITS PER FLOOR ARE REQUIRED. E.C. SHALL PROVIDE SERVICE AND A DISCONNECT PER CODE, AND DO ALL POWER WIRING, INCLUDING CONNECTING TO CONTROLS CONTRACTOR PROVIDED TRANSFORMERS AND EQUIPMENT. 3. 3 - FIRE AND /OR SMOKE DETECTION & ALARM SYSTEM, AS MAY BE REQUIRED BY THE OWNER, ARCHITECT, OR CODE AUTHORITY, IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. ALL ASPECTS OF THIS SYSTEM HAVE BEEN EXCLUDED BY THE MECHANICAL CONTRACTOR. SEISMIC RESTRAINING NOTES 1. ANY BASE- MOUNTED /SPRING - MOUNTED EQUIPMENT SHALL HAVE TOTALLY ENCLOSED, SEISMIC RATED SPRINGS (MASON MODEL SSLFH OR EQUAL), OR OPEN SPRINGS PLUS SEISMIC 'SNUBBERS" (MASON MODEL Z -1225 OR EQUAL). 2. ALL SPRING MOUNTED, SUSPENDED EQUIPMENT SHALL HAVE SEISMIC CABLES INSTALLED IN ADDITION TO EQUIPMENT HANGERS. CABLES SHALL BE INSTALLED DIAGONALLY UP AND AWAY FROM EQUIPMENT CORNERS AND BE ATTACHED TO THE STRUCTURE ABOVE. CABLES SHALL BE LEFT PARTIALLY SLACK. SIZE AND INSTALL CABLES PER SMACNA SEISMIC RESTRAINT MANUAL 3. ANY EQUIPMENT MOUNTED RIGIDLY TO THE BUILDING STRUCTURE SHALL NOT REQUIRE ADDITIONAL SEISMIC RESTRAINT. 4. RESTRAIN ALL RECTANGULAR DUCTS 6 SQ. FT. OF AREA AND LARGER AND ALL ROUND DUCTS 28' IN DIAMETER AND LARGER. RESTRAINTS SHALL OCCUR 30 FEET O.C. MAXIMUM AND SHALL BE INSTALLED AT EVERY DUCT TURN AND AT THE END OF THE DUCT RUN. SIZE AND INSTALL RESTRAINTS PER SMACNA SEISMIC RESTRAINT MANUAL. 5. ALL CEILING MOUNTED DIFFUSERS SHALL HAVE WIRES (16 GA.) ATTACHED TO THE ABOVE FLOOR SLAB OR STRUCTURE. SAFETY WIRES SHALL BE LEFT PARTIALLY SLACK. ALTERNATE METHOD SHALL BE TO ATTACH DIFFUSERS TO T--BAR GRID WITH SCREWS, RIVETS, OR CEILING CUPS FOR TERMINALS WEIGHING LESS THAN 20 POUNDS. AFF AP BHP BOD BOU BOH CLG CONN. D DB DN. DR. DXFC EA EAT E.C. EG ELEV. ESP EXH. EF EXTR. FC FD FFL FLA FLR. DR. FNL DR. FOB FOT FUT G ABOVE FINISHED FLOOR ACCESS PANEL BRAKE HORSE POWER BOTTOM OF DUCT BOTTOM OF UNIT BOTTOM OF HOOD CEILING CONNECT /CONNECTION DOWN DUCTBOARD DOWN DRAIN DIRECT EXPANSION FAN COIL EACH ENTERING AIR TEMP ELECTRICAL CONTRACTOR EXHAUST GRILLE ELEVATION EXTERNAL STATIC PRESSURE EXHAUST EXHAUST FAN EXTRACTOR FLEX CONNECTION FIRE DAMPER FINISHED FLOOR LEVEL FULL LOAD AMPS FLOOR DRAIN FUNNEL DRAIN FLAT ON BOTTOM FLAT ON TOP FUTURE GAS HVAC ABBREVIATIONS GC H HG HP ID INSUL LAT MCA N/A NC NIC NO NOM. NTS OA OBD OD PRIM PSI R RA RL RTU SA SL SM SP TYP VD W/ /W GENERAL CONTRACTOR HOOD HOT GAS UNE (REFRIGERANT) HORSE POWER INSIDE DIMENSION /DIAMETER INSULATION LEAVING AIR TEMP MINIMUM CIRCUIT AMPACITY NOT APPLICABLE NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN NOMINAL NOT TO SCALE OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION PRIMARY POUNDS PER SQUARE INCH RISE RETURN AIR REFRIGERANT LIQUID LINE ROOF TOP UNIT SUPPLY AIR SOUND LINING SHEET METAL STATIC PRESSURE TURNING VANES TYPICAL VOLUME DAMPER WITH WITH WRAP OE: DUCT INSULATION) GRILLES, REGISTERS, DIFFUSERS LEGEND X "xX" CD CFM X "xX" CD CFM #SLOT- INLETO SLOT DIFFUSER FOR LAY -IN CEILING CFM KEES -100 #SLOT- INLETO /FD SLOT DIFFUSER FOR RATED LAY -IN CETUNG WITH FIRE DAMPER CFM #SLOT- INLETo /P SLOT DIFFUSER (PLASTER CEILING) CFM A.S.H. AIR SUPPLY HOOD R.A.G. R.A.G. /ACCESS R.A.R. LN.W.R.G. E.G. /P. T.G. /P. NOTE ALL SUPPLY DIFFUSERS ARE TO BE INSTALLED WITH A DIFFUSER CAN W/ PERF DIVIDER, GENSCO REGISTER BOX W/ FLEX COLLAR & DIFF, MODEL COLDC21 OR EQUIV. CEIUNG DIFFUSER (SURFACE MOUNT) 4 CORE ADJUSTABLE, WITH FILLER FOR 24' x 24' MODULE TITUS MODEL MCD, BORDER TYPE - KRUEGER SERIES 1244, FRAME 23 (USE X "0 RUNOUT) CEILING DIFFUSER 4 CORE ADJUSTABLE, WITH FILLER FOR 24' x 24' LAY -IN MODULE KRUEGER SERIES 1244P, FRAME 23 (USE X" RUNOUT) (USE X" RUNOUT) CEILING DIFFUSER (PLASTER CEILING) 4 CORE ADJUSTABLE, 'V' FRAME TITUS MODEL MCD, BORDER TYPE 6 - KRUEGER SERIES 1244, FRAME 21 TEMPMASTER FRD KEES K -100, FRAME OPTION 12 SLOT DIFFUSER WITH ARE DAMPER (PLASTER CEILING) TEMPMASTER MODEL TFD -F OR FRD- -F FOR SURFACE MOUNTING RETURN AIR GRILLE ALUMINUM EGGCRATE WITH ' /x" x 1/2" x ' /2' CORE TITUS MODEL 50F - KRUEGER EG -5 RETURN AIR REGISTER FIXED 35 DEGREE DEFLECTION BLADES KRUEGER MODEL S8OH - TITUS MODEL 350RL LINEAR WALL RETURN GRILLE FIXED 0 DEGREE DEFLECTION BLADES KRUEGER MODEL 1500, FRAME 415 ALUMINUM CONSTRUCTION EXHAUST GRILLE ALUMINUM EGGCRATE WITH 1 /2" x 1/2" x 1/2" CORE TITUS MODEL 50F - KRUEGER EG -5 RETURN AIR GRILLE (PLASTER CEILING) AXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 350RL - KRUEGER MODEL S8OH EXHAUST REGISTER FIXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 350RL Q.B.D. - KRUEGER MODEL S8OH O.B.D. TRANSFER GRILLE ALUMINUM EGGCRATE WITH 1 /2" x 1 /2' x ' /2" CORE TITUS MODEL 50F - KRUEGER EG -5 TRANSFER GRILLE (PLASTER CEILING OR WALL) FIXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 350RL - KRUEGER MODEL S8OH SHEET METAL NOTES 1. DUCT SIZES INDICATED ON PLANS ARE NET INSIDE DIMENSIONS. A CALL -OUT SUCH AS 12' X 12' /SL MEANS A 14' X 14' SHEET METAL DUCT WITH 1" SOUNDUNER, GIVING A NET INSIDE DIMENSION OF 12' X 12'. 2. THROUGH PENETRATION AND MEMBRANE PENETRATION FIRE STOP AS REQUIRED IN THE UBC SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR. FIRE STOP SYSTEM SHALL BE 3M BRAND FIRE BARRIER CP 25WBT CAULKING OR APPROVED EQUIVALENT. NOTE: PER UBC 714 EXCEPTION: FIRE AND COMBINATION FIRE AND SMOKE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH THEIR LISTINGS. MANUFACTURER INSTALLATION INSTRUCTIONS DO NOT REQUIRE FIRE STOP BETWEEN SLEEVE AND ASSEMBLY PENETRATED. 3. DUCTWORK SHALL BE CONSTRUCTED TO DIMENSIONS INDICATED ON PLANS. THE TOLERANCE OF THESE DIMENSIONS SHALL BE AS SPECIFIED IN HOLADAY -- PARKS, INC. SHOP STANDARDS MANUAL. LENGTHS, AND CRITICAL DIMENSIONS BETWEEN DUCTWORK AND OTHER BUILDING /SYSTEM ELEMENTS ARE INDICATED WHERE A LOCATION OR DIMENSION SCALED FROM THE DRAWING WILL NOT BE ADEQUATE. THE TOLERANCE OF CRITICAL DIMENSIONS, IF NOT INDICATED, SHALL DEFAULT TO THAT OF THE INSTAWNG MECHANIC'S MEASURING DEVICES. SCALED LOCATIONS OR DIMENSIONS ARE NOT SUBJECT TO TOLERANCE GUIDELINES. 4. THESE PLANS HAVE BEEN COORDINATED WITH THE ARCHITECTURAL, STRUCTURAL, SPRINKLER AND ELECTRICAL DRAWINGS. ANY CHANGES IN THIS LAY -OUT MUST BE REVIEWED BY HOLADAY PARKS' ENGINEERING DEPARTMENT. 5. DUCT ELBOWS SHALL BE RADIUS TYPE WITH FULL WIDTH THROAT RADIUS, UNLESS SHOWN OTHERWISE. TURNING VANE ELBOWS SHALL HAVE DOUBLE THICKNESS TURNING VANES INSTALLED IN EVERY RAIL TAB. 6. R111-1, RTU-2, RTU -3 & MAU -1 UNITS DUCT CONSTRUCTION SHALL BE AS FOLLOWS: a. RUNOUTS TO DIFFUSERS SHALL BE LOW PRESSURE INSULATED FLEX DUCT (AND RIGID ROUND DUCT WHERE INDICATED). USE UNINSULATED FURNACE PIPE FITTINGS WHERE FITTINGS ARE INDICATED IN RIGID ROUND DUCT. FLEX DUCT SHALL BE LIMITED TO 8 FEET AND TWO 45 DEGREE TURNS. b. WHERE RETURN AIR IS DUCTED, RETURN AIR DUCTWORK SHALL BE SAME AS SUPPLY. c. ROOF TOP SUPPLY DUCTWORK FOR RTU -1, RTU-2, RTI -3 & MUA -1 UNITS SHALL BE AS FOLLOWS: 1. DUCTWORK FROM OUTSIDE OF BUILDING UP TO THE UNITS SHALL BE RECTANGULAR GALVANIZED SHEET METAL WITH 2' SOUNDUNER (OR MINIMUM R -7 DUCT INSULATION WHERE INDICATED). 2. SUPPLY & RETURN DISTRIBUTION DUCTWORK AFTER RTU -1, RTU - 2, RTU-3 & MAU-1 UNITS W/IN THE CEILING SPACE SHALL BE GALVANIZED. LINER AND /OR INSULATION SHALL BE MINIMUM R3.3. 3. FABRICATE AND INSTALL TO SMACNA 1/r PRESSURE CLASSIFICATION. 7. MATERIALS: a. SOUNDUNER (INDOORS): 1' THICK, 1-1/2 LB. DENSITY FIBERGLAS a DUCTUNER WITH BLACK MAT FACING. SCHULLER - MANVILLE "PERMACOTE:: UNACOUSTIC STANDARD', OWENS CORNING 'AEROFLEX PLUS', OR \ fF ' CERTAINTEED TOUGHGARD DUCT UNER WITH ENHANCED SURFACE. (MINIMUM INSTALLED R -VALUE = 3.3) b. INSULATED FLEX DUCT (LOW PRESSURE): UL 181 CLASS 1 AIR DUCT: THERMAFLEX MK -E. c. DUCT INSULATION (INDOORS): 1-1/2" THICK, 3/4 L.B. DENSITY FIBERGLASS . WITH F.S.K. VAPOR BARRIER JACKET. (MINIMUM INSTALLED R -VALUE d. KITCHEN GREASE AND DISHWASHER EXHAUST DUCTS SHALL BE 18 -GAUGE STAINLESS STEEL SHEETMETAL WITH CONTINUOUSLY WELDED JOINTS AND SEAMS. KITCHEN GREASE EXHAUST DUCTS SHALL BE WRAPPED CONTINUOUSLY WITH APPROVED FIRE WRAP PRODUCT. 12x12/W IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII HVAC LEGEND DUCT UNDER POSITIVE PRESSURE RECTANGULAR /SQUARE SUPPLY DUCT DOWN DUCT UNDER NEGATIVE PRESSURE RECTANGULAR /SQUARE RETURN /EXHAUST DUCT DOWN TURNING VANES EQUIPMENT IDENTIFICATION THERMOSTAT SENSOR SUPPLY AIR ARROW RETURN AIR ARROW FLEXIBLE CONNECTION MANUAL VOLUME DAMPER MOTORIZED DAMPER BACK DRAFT DAMPER SMOKE DETECTOR BACK DRAFT DAMPER RUSKIN MODEL BD2 /A1, LOCAL VELOCITY < 1500 FPM BACK DRAFT DAMPER RUSKIN MODEL BD2 /A2, LOCAL VELOCITY < 2500 FPM BACK DRAFT DAMPER RUSKIN MODEL BD6, LOCAL VELOCITY < 3500 FPM SPIN -IN TAKE -OFF & VOLUME DAMPER ACCESS DOOR VERTICAL COMBINATION SMOKE AND FIRE DAMPER INDICATES UNLINED 12' x 12" S.M. DUCT INDICATES UNLINED 1 x 12" S.M. DUCT WITH INSULATED WRAP RISE OR DROP IN DIRECTION OF FLOW FLEXIBLE DUCT ACCESS PANEL ROUND DUCT UP ROUND DUCT DOWN SEPARATE PERMIT RED FOR 0 mechanical ,Piterechical Gas Piping City of Tukwila BUILDING DIVISION REVISIONS • No changes shall be made to the scope of work without prior approval of Tukwila Building Division. COTE Revisions will require a new plan submittal ' 7 ni may include additional plan reiipw fees. j DRAWING XREF DATES trade: REV # SHEET # SHEET TITLE 1 M0.01 M1.01 1 M2.01 1 M2.02 1 M2.03 M6.01 M7.01 SHEET INDEX HVAC LEGENDS AND NOTES PLOT PLAN HVAC 1ST FLOOR PLAN HVAC 2ND FLOOR PLAN HVAC 3RD FLOOR PLAN HVAC DETAILS HVAC SCHEDULES VICINITY MAP Sauthcinter li,fo Sunder 6 }v d . s ff Sirareka Stvd 0 0 0 0 0 0 0 0 0 DESIGN CRITERIA BASIS OF DESIGN 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 WSEC (CHAPTER 51 -11 WAC) 2006 WSVIAQ CODE SECTIONS 202 OSA DESIGN TEMP = 83'F DB, 67'F WB ISA DESIGN TEMP = 70T HEATING, 75T COOUNG PEOPLE DENSITY: A. DINING: 221 PERSON B. KITCHEN (COOKING) : 1OPERSON VENTILATION REQUIREMENTS A. DINING : 20 CFM PER PERSON B KITCHEN (COOKING) : 15 CFM PER PERSON FLOOR DATA: U= 0.1 ROOF DATA = 0.1 GLASS DATA U = 0.5, SC = 0.6 WALL DATA = 0.15 FLOOR DATA U- 0.1 CRITERIA SOURCE EFFECTIVE JANUARY, 2006 EFFECTIVE JANUARY, 2006 EFFECTIVE JULY 1, 2007 EFFECTIVE JULY 1, 2007 2006 WSEC 2006 WSEC HEAD COUNT HEAD COUNT CHAPTER 3 OF WSVIAQC TABLE 3 -4 CHAPTER 3 OF WSVIAQC TABLE 3 -4 HP ASSUMPTION PER CONY. W/ ARCH. HP ASSUMPTION PER CONV. W/ ARCH. HP ASSUMPTION PER CONV. W/ ARCH. HP ASSUMPTION PER CONV. W/ ARCH. HP ASSUMPTION PER CONY. W/ ARCH. LEGAL DESCRIPTION POR OF NE 1/4 OF NW 1/4 & OF VAC STS DAF N 72.35 FT OF NE 1/4 OF NW 1/4 LY WLY OF C/L VAC 57TH AVE S & S 158 FT OF N 230.35 FT OF E 581.04 FT OF NW 1/4 OF NE 1/4 OF NW 1/4 & POR BEG NE COR OF SUBD TH S 552.42 FT TH N 89 -31 -13 W TO C/L VAC 57TH AVE 5 TH NLY ALG SD C/L TO N LN OF SUBD TH E TO BEG LESS N 10.83 FT OF E 44.90 FT THOF LESS POR WITHIN FOLG BEG N 89 -40 -24 W 23 FT & 5 00 -19 -36 W 433.24 FT FR NE COR OF SUBD TH S 00 -19 -36 E 236.16 FT TH S 89 -40 -24 E 119 FT TH N 00 -19 -36 E 21.42 FT TH S 89 -40 -24 E 183 FT TO BEG LESS PARCEL AND /OR PARCELS PER US DIST CT W DIST OF WASH N DIV DEC OF TAKING CIVIL # 6010 SCOPE OF WORK -- 11164223 1. FURNISH AND INSTALL (3EA ) ROOF TOP UNITS (HEATING AND COOLING), (4EA) EXHAUST FANS, KITCEHN HOODS, DISHWASHER HOOD, SUPPORTS, CONTROL AND RELATED ACCESSORIES. 2. FURNISH AND INSTALL (1 EA) DX FAN COIL (2EA) CONDENDENSING UNITS, 1 EA MAKE UP AIR UNIT REFRIGERANT PIPING, INSULATIONS, CONTROLS AND RELATED ACCESSORIES. 3. FURNISH AND INSTALL 1 EA AIR DOOR AND 6EA GAS RADIANT HEATERS, SUPPORTS AND CONTROL AND RELATED ACCESSORIES. 4.. FURNISH AND INSTALL HVAC DUCTS, DIFFUSERS, RETURN GRILLES, TRANSFER GRILLES, VOLUME DAMPERS, FIRE AND SMOKE DAMPERS, DUCT INSULATION, SUPPORTS AND NECESSARY ACCESSORIES AS INDICATED. 5. PROVIDE AND INSTALL 2EA POWER VENTS FOR FIREPLACE AND 2EA COMBUSTION AIR SUPPLY FAN FOR GAS FIRED WATER HEATER INCL SUPPORTS AND RELATED ACCESSORIES. 6. PROVIDE AND INSTALL DDC, MOTORIZED DAMPERS AND RELATED ACCESSORIES. 7. TEST, RUN, ADJUST AND AIR BALANCE THE AIR SYSTEM. CORRECTION LTR# RECEIVED CITY OF TUKWILA NOV 3 0 2007 PEHMIT CENTER PENDING CITY PPROVAL date: APPROVED FOR CONSTRUCTION date of last revision: cadd file name: W frf fX Lu r a N ra 1- a Cs ca N 0 La w IX N N co N Ion 10r24o8 1/29/07 B VENT -UL LISTED, INSTALL PER FIREPLACE—' MANUFACTURER'S INSTRUCTIONS. MECHANICAL DRAFT SYSTEM TO COMPLY WITH IMC (2006) 804.3.8. 12x11 - CD 350 24x10 DN 1 i - ,_..y.� ]4 R L UP - 2x12' CD /P '1290(TYP.6)., • !8](10 � O 1 12 "0 TOx49 CD MI , 0XFC -0111 ' -M _ ....- ... -. _ 1 _ _.._. _ �_ . �.. 1 t z f: Otfr-Wii" li N � pr r�r�■�n r■■w��r_rwrr�Jtr7 L r ��.��ii 1 i�IS�` � 0 I� � 1114.4h .[ fi r7R► ="` rI r im � i �1�• F ►'� t � t r Tn I11If IARiif1 I i p. - t - --- - - _ a - -rte• Ijl Jil�r� 7vtlL' mfg \wLil ����n„a• ��ill��v.- ,1 '[I i , �rt� . "', •-- IEEE -♦ la = A N •Y. i — _— - — :Ja r t'w�..l �� —kirk mom — - 1 -,=., i r ` 1 16x n _ --� 1 -_ ..- A _ 1711112 ,�� i I �� i ° � III �- 1 'iIpi'I:fi n ■L' ® Eaa11R1.MI 1 �1 _a - i..am i6:./1 ma : u ■� " t ■, mum arm ...e ..,,, memo . ,�i_ ■_U ----�. " ---F, — —.' - e ' - rt� ...� i" r , LIF '2R 12x12 CD J0OMP.. 10x10 CD P 350 TYP.1 Q d / //1 I I I I 2x12 RAG 12-11411P _rte -: ,• 1 1 u+'C{ I o t1 i I . - - .1495- -." ���� � -..... -. .- # N 1 --1- -± (62o,4) 1. 1 1 =wan ° j i 7._ � zai LI Tea I _ — 1 , 11 I� I iI±iP lirfit . K{TCH 370 LB �` 1200 C I K ^ 38 STC PAS Mil ►6 -1 CLOSE Ic . _�,_I ti -° 10x1 0 OPENING(TYP.2 ii ��I - - C6200 it .1 .I ,_ 10x10 ECM - I t ( . i '24x30'RAG/P OPENING TO R M3.01 11111111111 TO RTU- -2 AT ROOF 4* PVC UP FW 4' PVC UP PVC UP FW 4' PVC UP 8'O B VENT UP (EXHAUST) 8'0 VENT UP (INTAKE) \ CA 74' PVC W/ FIRE WRAP 18x6 TG (TYP.2) 24x6 TG (TYP.2) FIRST FLOOR HVAC PLAN Scale: 1/4" - f-O RH -1 (50 MBH) 0 J p L_1 1 S.3 trade: ARCHITECTURAL S8 ARCHITECTURAL TI ( 48x18 RA OPENING —J 8x18 RA OPENING 0 RAG /P I STOG Lc_ -- METh E LEGEND = EXISTING CONSTRUCTION = NEW CONSTRUCTION - FUTURE CONSTRUCTION - DEMOLITION - TENANT BOUNDARY KEYED NOTES Q1 DUCT SHALL BE FIREWRAP. O DUCT SHALL BE STAINLESS STEEL FOR DISHWASHER AND GREASE EXHAUST DUCTS. 0 TYPE I DUCT SHALE WELDED STAINNLSS STEEL a 18. SHEET NOTES DRAWING XREF DATES date: trade: date: APPROVED cc — FOR CONSTRUCTION , -L g ➢ 4 5R., v 0 E Ur � � .. , i:6 4,;, a.Y 1 q , , sp' 1 4' PVC- MAX EQUIVALENT LENGTH FOR INTAKE VENT AND EXHAUST VENT = 120 FT EACH. MAXIMUM # OF ELBOWS = 6 EACH. 4' PVC ELBOW = 5 FEET. . KITCHEN GREASE AND DISHWASHER EXHAUST DUCTS SHALL BE 18 -GAUGE STAINLESS STEEL SHEETMETAL WITH CONTINUOUSLY WELDED JOINTS AND SEAMS. KITCHEN GREASE EXHAUST DUCTS SH BE WRAPPED CONTINUOUSLY WITH APPROVED FIRE WRAP PRODUCT. . KITCHEN HOODS FIRE SUPPRESSION SYSTEM SHALL BE CONNECTED TO LANDLORD'S FIRE ALARM SYSTEM. 4. HORIZONTAL GREASE DUCT SHALL BE SLOPE NOT LESS THAN ONE UNIT VERTICAL IN 12 UNITS HORIZONTAL (8.3% SLOPE)- . PROVIDE CLEANOUT FOR HORIZONTAL GREASE DUCT AT NOT MORE THAN 20 FT APART. 6. FOR HORIZONTAL INSTALLATIONS THE LONGEST BVENT RUN IS 100 FT WITH A LIMIT OF 4-90 DEG ELBOW OR 8 -45 DEG ELBOW. RECEIVED CITY OF TUKWILA NOV 3 0 2007 PEHIVIIT CENTER PENDING CITY APPROVAL approvgd:!4 r date: E v E • w C/3 CC w w N N C CO qft 1- re Ch ■ LL Lh n C] CNI r I B+D/ 24 /CB 11/29/07 er r eihno. ao v 41‘ oo a 0 ELI N II m m a eq 11111 m d 3 4 co 1111 N M CO MC op 1 c "a W date of last revision: 11/29/07 M2.01 cadd file name: M201 to Ce am 0 W Z W U N .0 a r a i l IOU • B VENT -UL LISTED, INSTALL PER FIREPLACE—' MANUFACTURER'S INSTRUCTIONS. MECHANICAL DRAFT SYSTEM TO COMPLY WITH IMC (2006) 804.3.8. 12x11 - CD 350 24x10 DN 1 i - ,_..y.� ]4 R L UP - 2x12' CD /P '1290(TYP.6)., • !8](10 � O 1 12 "0 TOx49 CD MI , 0XFC -0111 ' -M _ ....- ... -. _ 1 _ _.._. _ �_ . �.. 1 t z f: Otfr-Wii" li N � pr r�r�■�n r■■w��r_rwrr�Jtr7 L r ��.��ii 1 i�IS�` � 0 I� � 1114.4h .[ fi r7R► ="` rI r im � i �1�• F ►'� t � t r Tn I11If IARiif1 I i p. - t - --- - - _ a - -rte• Ijl Jil�r� 7vtlL' mfg \wLil ����n„a• ��ill��v.- ,1 '[I i , �rt� . "', •-- IEEE -♦ la = A N •Y. i — _— - — :Ja r t'w�..l �� —kirk mom — - 1 -,=., i r ` 1 16x n _ --� 1 -_ ..- A _ 1711112 ,�� i I �� i ° � III �- 1 'iIpi'I:fi n ■L' ® Eaa11R1.MI 1 �1 _a - i..am i6:./1 ma : u ■� " t ■, mum arm ...e ..,,, memo . ,�i_ ■_U ----�. " ---F, — —.' - e ' - rt� ...� i" r , LIF '2R 12x12 CD J0OMP.. 10x10 CD P 350 TYP.1 Q d / //1 I I I I 2x12 RAG 12-11411P _rte -: ,• 1 1 u+'C{ I o t1 i I . - - .1495- -." ���� � -..... -. .- # N 1 --1- -± (62o,4) 1. 1 1 =wan ° j i 7._ � zai LI Tea I _ — 1 , 11 I� I iI±iP lirfit . K{TCH 370 LB �` 1200 C I K ^ 38 STC PAS Mil ►6 -1 CLOSE Ic . _�,_I ti -° 10x1 0 OPENING(TYP.2 ii ��I - - C6200 it .1 .I ,_ 10x10 ECM - I t ( . i '24x30'RAG/P OPENING TO R M3.01 11111111111 TO RTU- -2 AT ROOF 4* PVC UP FW 4' PVC UP PVC UP FW 4' PVC UP 8'O B VENT UP (EXHAUST) 8'0 VENT UP (INTAKE) \ CA 74' PVC W/ FIRE WRAP 18x6 TG (TYP.2) 24x6 TG (TYP.2) FIRST FLOOR HVAC PLAN Scale: 1/4" - f-O RH -1 (50 MBH) 0 J p L_1 1 S.3 trade: ARCHITECTURAL S8 ARCHITECTURAL TI ( 48x18 RA OPENING —J 8x18 RA OPENING 0 RAG /P I STOG Lc_ -- METh E LEGEND = EXISTING CONSTRUCTION = NEW CONSTRUCTION - FUTURE CONSTRUCTION - DEMOLITION - TENANT BOUNDARY KEYED NOTES Q1 DUCT SHALL BE FIREWRAP. O DUCT SHALL BE STAINLESS STEEL FOR DISHWASHER AND GREASE EXHAUST DUCTS. 0 TYPE I DUCT SHALE WELDED STAINNLSS STEEL a 18. SHEET NOTES DRAWING XREF DATES date: trade: date: APPROVED cc — FOR CONSTRUCTION , -L g ➢ 4 5R., v 0 E Ur � � .. , i:6 4,;, a.Y 1 q , , sp' 1 4' PVC- MAX EQUIVALENT LENGTH FOR INTAKE VENT AND EXHAUST VENT = 120 FT EACH. MAXIMUM # OF ELBOWS = 6 EACH. 4' PVC ELBOW = 5 FEET. . KITCHEN GREASE AND DISHWASHER EXHAUST DUCTS SHALL BE 18 -GAUGE STAINLESS STEEL SHEETMETAL WITH CONTINUOUSLY WELDED JOINTS AND SEAMS. KITCHEN GREASE EXHAUST DUCTS SH BE WRAPPED CONTINUOUSLY WITH APPROVED FIRE WRAP PRODUCT. . KITCHEN HOODS FIRE SUPPRESSION SYSTEM SHALL BE CONNECTED TO LANDLORD'S FIRE ALARM SYSTEM. 4. HORIZONTAL GREASE DUCT SHALL BE SLOPE NOT LESS THAN ONE UNIT VERTICAL IN 12 UNITS HORIZONTAL (8.3% SLOPE)- . PROVIDE CLEANOUT FOR HORIZONTAL GREASE DUCT AT NOT MORE THAN 20 FT APART. 6. FOR HORIZONTAL INSTALLATIONS THE LONGEST BVENT RUN IS 100 FT WITH A LIMIT OF 4-90 DEG ELBOW OR 8 -45 DEG ELBOW. RECEIVED CITY OF TUKWILA NOV 3 0 2007 PEHIVIIT CENTER PENDING CITY APPROVAL approvgd:!4 r date: E v E • w C/3 CC w w N N C CO qft 1- re Ch ■ LL Lh n C] CNI r I B+D/ 24 /CB 11/29/07 er r eihno. ao v 41‘ oo a 0 ELI N II m m a eq 11111 m d 3 4 co 1111 N M CO MC op 1 c "a W date of last revision: 11/29/07 M2.01 cadd file name: M201 to Ce am 0 W Z W U N .0 a r a i l IOU B VENT -UL LISTED, INSTALL PER FIREPLACE—' MANUFACTURER'S INSTRUCTIONS. MECHANICAL DRAFT SYSTEM TO COMPLY WITH IMC (2006) 804.3.8. 12x11 - CD 350 24x10 DN 1 i - ,_..y.� ]4 R L UP - 2x12' CD /P '1290(TYP.6)., • !8](10 � O 1 12 "0 TOx49 CD MI , 0XFC -0111 ' -M _ ....- ... -. _ 1 _ _.._. _ �_ . �.. 1 t z f: Otfr-Wii" li N � pr r�r�■�n r■■w��r_rwrr�Jtr7 L r ��.��ii 1 i�IS�` � 0 I� � 1114.4h .[ fi r7R► ="` rI r im � i �1�• F ►'� t � t r Tn I11If IARiif1 I i p. - t - --- - - _ a - -rte• Ijl Jil�r� 7vtlL' mfg \wLil ����n„a• ��ill��v.- ,1 '[I i , �rt� . "', •-- IEEE -♦ la = A N •Y. i — _— - — :Ja r t'w�..l �� —kirk mom — - 1 -,=., i r ` 1 16x n _ --� 1 -_ ..- A _ 1711112 ,�� i I �� i ° � III �- 1 'iIpi'I:fi n ■L' ® Eaa11R1.MI 1 �1 _a - i..am i6:./1 ma : u ■� " t ■, mum arm ...e ..,,, memo . ,�i_ ■_U ----�. " ---F, — —.' - e ' - rt� ...� i" r , LIF '2R 12x12 CD J0OMP.. 10x10 CD P 350 TYP.1 Q d / //1 I I I I 2x12 RAG 12-11411P _rte -: ,• 1 1 u+'C{ I o t1 i I . - - .1495- -." ���� � -..... -. .- # N 1 --1- -± (62o,4) 1. 1 1 =wan ° j i 7._ � zai LI Tea I _ — 1 , 11 I� I iI±iP lirfit . K{TCH 370 LB �` 1200 C I K ^ 38 STC PAS Mil ►6 -1 CLOSE Ic . _�,_I ti -° 10x1 0 OPENING(TYP.2 ii ��I - - C6200 it .1 .I ,_ 10x10 ECM . i '24x30'RAG/P OPENING TO R M3.01 11111111111 TO RTU- -2 AT ROOF 4* PVC UP FW 4' PVC UP PVC UP FW 4' PVC UP 8'O B VENT UP (EXHAUST) 8'0 VENT UP (INTAKE) \ CA 74' PVC W/ FIRE WRAP - I t 24x6 TG (TYP.2) FIRST FLOOR HVAC PLAN Scale: 1/4" - f-O RH -1 ( 0 J p L_1 1 S.3 trade: ARCHITECTURAL S8 ARCHITECTURAL TI ( 48x18 RA OPENING —J 8x18 RA OPENING 0 RAG /P I STOG Lc_ -- METh E LEGEND = EXISTING CONSTRUCTION = NEW CONSTRUCTION - FUTURE CONSTRUCTION - DEMOLITION - TENANT BOUNDARY KEYED NOTES Q1 DUCT SHALL BE FIREWRAP. O DUCT SHALL BE STAINLESS STEEL FOR DISHWASHER AND GREASE EXHAUST DUCTS. 0 TYPE I DUCT SHALE WELDED STAINNLSS STEEL a 18. SHEET NOTES DRAWING XREF DATES date: trade: date: APPROVED cc — FOR CONSTRUCTION , -L g ➢ 4 5R., v 0 E Ur � � .. , i:6 4,;, a.Y 1 q , , sp' 1 4' PVC- MAX EQUIVALENT LENGTH FOR INTAKE VENT AND EXHAUST VENT = 120 FT EACH. MAXIMUM # OF ELBOWS = 6 EACH. 4' PVC ELBOW = 5 FEET. . KITCHEN GREASE AND DISHWASHER EXHAUST DUCTS SHALL BE 18 -GAUGE STAINLESS STEEL SHEETMETAL WITH CONTINUOUSLY WELDED JOINTS AND SEAMS. KITCHEN GREASE EXHAUST DUCTS SH BE WRAPPED CONTINUOUSLY WITH APPROVED FIRE WRAP PRODUCT. . KITCHEN HOODS FIRE SUPPRESSION SYSTEM SHALL BE CONNECTED TO LANDLORD'S FIRE ALARM SYSTEM. 4. HORIZONTAL GREASE DUCT SHALL BE SLOPE NOT LESS THAN ONE UNIT VERTICAL IN 12 UNITS HORIZONTAL (8.3% SLOPE)- . PROVIDE CLEANOUT FOR HORIZONTAL GREASE DUCT AT NOT MORE THAN 20 FT APART. 6. FOR HORIZONTAL INSTALLATIONS THE LONGEST BVENT RUN IS 100 FT WITH A LIMIT OF 4-90 DEG ELBOW OR 8 -45 DEG ELBOW. RECEIVED CITY OF TUKWILA NOV 3 0 2007 PEHIVIIT CENTER PENDING CITY APPROVAL approvgd:!4 r date: E v E • w C/3 CC w w N N C CO qft 1- re Ch ■ LL Lh n C] CNI r I B+D/ 24 /CB 11/29/07 er r eihno. ao v 41‘ oo a 0 ELI N II m m a eq 11111 m d 3 4 co 1111 N M CO MC op 1 c "a W date of last revision: 11/29/07 M2.01 cadd file name: M201 to Ce am 0 W Z W U N .0 a 12'0 DN LD2 -2100 (2 TYP) 30x30/W UP & DN 14 "0/WUP& D 20 "0 /FW DN 25"o /FW DN 24'0/W' SA DN & 16"0 DN 28x28/W SA DN & UP trade: date: DRAWING XREF DATES trade: date: FSD'S NOT PROVIDED WHERE TYPE I EXHAUST PENETRATES SHAFT SINCE DUCT IS PROVIDED WITH FIRE WRAP 20 "0 /FW LINETYPE LEGEND EXISTING CONSTRUCTION NEW CONSTRUCTION FUTURE CONSTRUCTION DEMOIJTION TENANT BOUNDARY 4 " PVC DN & UPFW 4 " PVC DN &U 4' PVC DN & UP FW 4 " PVC DN &U 8 "OB VENT DN &UP 8N0 B1 J DN & UP 0 SECOND FLOOR HVAC PLAN Scale: 1/4' • 1 1 . 4" PVC- MAX EQUIVALENT LENGTH FOR INTAKE VENT AND EXHAUST VENT = 120 FT EACH. MAXIMUM ii OF ELBOWS = 6 EACH. 4` PVC ELBOW = 5 FEET. 2. KITCHEN GREASE AND DISHWASHER EXHAUST DUCTS SHALL BE 18 -GAUGE STAINLESS STEEL SHEETMETAL WITH CONTINUOUSLY WELDED JOINTS AND SEAMS. KITCHEN GREASE EXHAUST DUCTS S BE WRAPPED CONTINUOUSLY WITH APPROVED FIRE WRAP PRODUCT. 3. KITCHEN HOODS FIRE SUPPRESSION SYSTEM SHALL BE CONNECTED TO LANDLORD'S FIRE ALARM SYSTEM. 4. HORIZONTAL GREASE DUCT SHALL BE SLOPE NOT LESS THAN ONE UNIT VERTICAL IN 12 UNITS HORIZONTAL (8.3% SLOPE). 5. PROVIDE CLEANOUT FOR HORIZONTAL GREASE DUCT AT NOT MORE THAN 20 FT APART. ARCHITECTURAL S &C - ARCHITECTURAL TI - SHEET NOTES OUTUNE OF SHAFT BY G.C. CD2 -245 18 1 CC � . 5= - E' y b f Y °, sg y Of g�ser•.,.G 9 i M KEYED NOTES 0 DUCT SHALL BE FIREWRAP. 02 DUCT SHALL BE STAINLESS STEEL FOR DISHWASHER EXHAUST. 03 TYPE I DUCT SHALL BE WELDED STAINLESS STEEL GA. 18. PENDING CITY APPROVAL NOT APPROVED FOR CONSTRUCTION RECEIVED CITY OF TUKV LA OCT 3 0 2007 PERMIT CENTER date: [ co 0 a E a a 0 I /O -43- 0 7 g i tifir LIE in � o V W In 03 0 CIL a I 3N il Z . ' o 0 N J m 15 v 0. 111111C to N. N M iftmll It Ctunie. Vj O • O � J W Q WL GO E6 aN OVA v) = J x,03 LL1 M ar- O 1/40 I- date of last revision: 10/22/07 M2.02 cadd file name: M202 f A 1 yinui B1 re - 8"0 B VENT UP TO POWER VENT AT ROOF (EXH AIR) B VENT L LISTED, INSTALL PER FIREPLACE MANUFAI RER'S INSTRUCTIONS. MECHANICAL DRAFT S STEM TO COMPLY WITH IMC (2006) 804.3.8. ILL 4• PVC DN FW 4. PVC DN 4" PVC DN FW 4* PVC DN 8'0 B VENT DN 8"0. VENT DN HO \\ ),00 In \U C-UP- INTAIT AIR 4" PVC UP INTAKE AIR FC7 YP 4' PVC UP EXH AIR 4' PVC UP EXH AIR WJv L\\\ A A FAV A Girarigire AFACKIMGFAM THIRD FLOOR HVAC PLAN Scale: 1/4• 1 1/8' HG DN 5/8' RL DN 30x30 SA DN \\ 24x24/ \ S \ L \ SA 36x20/SL SA DN 22x22/ WT: 300 IBS J-LOCATE UNIT PER / STRUCTURAL DWG 30x26/EL OUTLINE OF SHAFT 3Y G.C. IRTU-2 WT: 2700 LBS OCATE UNIT PER STRUCTURAL DWG ,-LOCATE UNIT PER / STRUCTURAL DWG 32x64 ROOF OPENING FOR FUTURE TENA\T CAP WATERTIGHT (TYP) Ft j - LOCATE UNIT PER STRUCTURAL DWG IEF-4 1 WT: 150 LBS trade: 1M UA-1 I WT: 3510 LBS 25"gs DN ARCHITECTURAL S&C - ARCHITECTURAL Ti - DRAWNG XREF DATES date: trade: 250 LOCATE UNIT PER STRUCTURAL DWG IEF- 2 I WT LOCATE UNIT STRUCTUR SEE D WT: 510 LBS LOCATE UNIT PER STRUCTURAL DWG IEF-3 1 FC WT: 170 LBS LOCATE UNIT PER STRUCTURAL DWG date: IEF-1 1 SEE DE1JL 2/M6.02 \ • WT: 980 LBS \— LOCATE UNIT PER STRUCTUR DWG 1 I Ti: '" f' - --67 3 -- ' j • - 1 ' '; F''''0 7 0 .--- ... ,-, ,. - L. ! .'" ' Lai L • . • _______ CLy c. 7 ; E • - ":71 - - • - RECEIVED CITY OF TUKWILA NOV 3 0 2007 PEWIT OEM ER LINETYPE LEGEND ▪ EXISTING CONSTRUCTION NEW CONSTRUCTION • FUTURE CONSTRUCTION - DEMOUTION • TENANT BOUNDARY KEYED NOTES 0 DUCT SHALL BE FIREWRAP. O DUCT SHALL BE STAINLESS STEEL FOR DISHWASHER EXHAUST. ® TYPE I DUCT SHALL BE WELDED STAINLESS STELL GAGE 18. ® BY OTHER TENANT PENDING CITY APPROVAL APPROVED FOR CONSTRUCTION E Cs CV ■, Cs co LiJ 1— 1• CNI N. CNJ 11Exwea 13/24/013 11/29/07 •• c 0 apptv cadd file name: e: ‘‘AV M2O3 o . a date of last revision: 11/29/07 M2.03 ■••■■•■■ GROUND IRTU -11 MEI E -1 GROUND LEVEL , J L IEF -4 I IEF - 21 IEF -31 NOTE: 1. SEE SCHEDULE IN DWG SHT M7.01 IEF -11 BUILDING & EQUIPMENT ELEVATION Scale: 3/16" = 1' -0" IRTU-2 L SECTION -- RADIANT HEATER RH -1 (U- --BEND TUBE) Scale: N.T.S. ICU -02 I FFL IRTU - ICU -01 1 JMAU -1 TOP } 10' MIN. BELOW 60' MIN. $' MIN. BEHIND DETAIL - CLEARANCES TO COMBUSTIBLE Scale: N.T.S. GROUND LEVEL R 9 I a NOTE: 1. SEE SCHEDULE IN DWG SHT M7.01 N RH -2 FFL SECTION - RADRANT HEATER RH -2 (STRAIGHT TUBE) Scale: N.T.S. DETAIL - CLEARANCES TO COMBUSTIBLE Scale: N.T.S. DRAWNG XREF DATES trade: date: ARCHITECTURAL S&C - ARCHITECTURAL 11 - trade: date: AMA 4 . 3 APPROVED FOR CONSTRUCTION RECEIVED CITY OF TUKWW /ILA OCT 3 0 2Uui PERMIT CENTER PENDING CITY APPROVAL date: °7 a E ti v ro 0I o M 0 n Z W 0. W 0/24/ sa.rea +4/avae all■1114 m a I ND I R `° cam! ei cf5 tc1) I ' ao 0 iumme L e .0 C .0 CN 0 z d c m L O E -0 L e II e > .. e mt c i Q d- 5 a- e� cO n. Le •a— 0L7 a � J W Q W < 00 ce tE OVA (/) _ l e, 0 0 M date of last revision: 10/22/07 M3.01 cadd file name: M301 FASTENER SCHEDULE A B . EQUIP. SYM. UNIT DIMENSIONS C WEIGHT 22.5"x22.5" # OF 16GA STRAPS # OF FAST. PER STRAP 0 INSIDE OF CURB DIMENSIONS CI L W H 17.5 "x17.5" LBS ' 22 "x22" L W H WEIGHT RTU-1 105'/4 96% 55'/2 I 3700 © 8 2J 6 1/4" x 13 1/4" 94 511/4 44 400 RTU -2 102.3 87.9 - 2300 30 8 9 6 73'Va 51 7 116 32 400 RTU -3 102.6 74.9 - 1600 ® 8 Q 6 73'/a 51 32 400 REF# A B C D BDD LINER EF -2 22.5"x22.5" 24"x24" 27"x27 28 " .5x28.5 YES - EF-3 16"x16" 17.5 "x17.5" 20.5 "x20.5" 22 "x22" YES - 9 1 226 -350 ' 10 "4 12" x 12" 11 I 351 -500 12 "0 14" x 14" 13 1/4" x 13 1/4" ' 501 -675 14 "0 REF# I A B C 0 BDD LINER EF -4 13 "x13" 14.5 "x14.5" 17.5 "x17.5" 19 "x19" YES YES 6 "0 8" x 8" 7 1/4" x 7 3 /4" 126 -225 8 °0 10" x 10° 9 1 226 -350 ' 10 "4 12" x 12" 11 I OUTS CAS1 105 4' SEE DETAIL 4 DETAIL - RTU-1 UNIT DIMENSION Scale: N.T.S. di" TOP OF CURB MUST BE LEVEL & FLAT (SEE NOTES 1 & 2) 2x6 WOOD BACKING BY 16 GAUGE ROOF CURB - (BY A/C MFG) APPROXIMATE EDGE OF ROOF OPENING L No. 10x /8" SCREW SEAL & MAKE WATERTIGHT fr -------- STOP ROOFING FELT BEFORE CURB LIP SHEETMETAL FLASHING INSTALLED OVER ROOFING FELT. (BY MECH.) AC UNIT BUILT-UP ROOFING CANT STRIP (SEE NOTE 3) ROOF DECK NOTES: 1. GENERAL CONTRACTOR SHALL PROVIDE SHIMS AS REQUIRED TO MAKE CURB LEVEL. MAXIMUM ALLOWABLE SLOPE IS 1/4" PER 10'. 2. TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. 3. ROOF STRUCTURE, ROOF DECK, INSULATION, CANT STRIP & BUILT -UP ROOFING BY GENERAL CONTRACTOR. 4. STRUCTURAL MEMBERS MUST NOT INTERFERE WITH ROOF OPENINGS. 4" WIDE x 16GA SEISMIC RESTRAINTS QUANTITY AND CONNECTION PER TABLE BELOW NOMINAL 2° RIGID INSULATION (SEE NOTE 3) FASTEN ROOF CURB TO DECK PER STRUCTURAL ENGINEER o� o� (3) #12 METAL SCREWS (3) 1/2"0 LAG BOLTS 0 SEE STRAP DETAIL FOR FASTENER TYPE AND SIZE • 2 STRAPS AT EACH LONG SIDE, 2 STRAP AT EACH SHORT SIDE. ® UNIT WEIGHT INCLUDES 200 LBS FOR MECHANICAL DUCT. 0 APPROXIMATE DATA, VERIFY CUT SHEET. DETAIL - CURB W /SEISMIC RESTRAINT Scale: N.T.S. 61)1 II I 4 : 3.938' ■ 4.563" GI q2z) m � CD co m mN m n r- > z 0 12.688' -( 16.625" 21.5' 78.125' CONDENSER COIL T 0 z 0 m z G7 m Cn 2 SEE DETAIL 4 0 Z �- 24.094" 23.25' / 13.5" / 3" 102.344' DETAIL - RTU -2 UNIT DIMENSION Scale: N.T.S. \ At GREASE DRAIN CURB DRAIN )F PLAN FOR LOCATION B.D.D. A SHEETMETAL BY HP B ROOF OPENING OUTSIDE OF CURB GASKET FASTEN FAN TO CURB ANGLE AND FASTENERS NOTE: ROOF OPENING, CURB, CANT STRIP, & ROOFING BY G.C. 1. 'A' = DUCT SIZE, 'B' = 'A' + 2" (OR 'A' + 1" MIN), C = D - 1.5 ", D =FAN BASE O.D., 'B' MUST BE 3" SMALLER THAN 'C' 2. KEC- KITCHEN EQUIPMENT CONTRACTOR. DETAIL - EXHAUST FAN MTG Scale: N.T.S. 2 "X ° CURB 4 0 N ■ ,. 8.75' CONDENSER COIL r I 0 16.625'21.5' 78.094" to I J - r SEE DETAIL 4 c) 0 1 OS TO OS BASE LENGTH 77.875' 23.25' 13.5' 3 DETAIL - RTU-3 UNIT DIMENSION Scale: N.T.S. / 3' 2' -04' t B.D.D. A SHEETMETAL B ROOF OPENING C OUTSIDE OF CURB GASKET FASTEN FAN TO CURB ANGLE AND FASTENERS NOTE: ROOF OPENING, CURB, CANT STRIP, & ROOFING BY G.C. 'A' = DUCT SIZE, ' B = 'A' + 2" (OR 'A' + 1" MIN), C = D - 1.5 ", D =FAN BASE 0.D., 'B' MUST DE 3" SMALLER THAN 'C' 0 , DETAIL - ROOF EXHAUST FAN Scale: N.T.S. 1/2 DUCT SIZE -I. 3" / 1 SHEETMETAL DIFFUSER CAN DIFFUSER LOW PRESSURE INSULAIED FLEX DUCT, THERMAFLEX MK -E MAX 8' LENGTH CRIMP AND BARB TAP -IN EQ. EQ. A - CAN SIZE NOTES 1. CHART BASED ON TITUS MODEL MCD OR KRUEGER MODEL 1244 '4" 2. CFM RANGE & TAP -IN SIZE TYPICAL U.N.O. ON DWGS. PERFORATED METAL %"DIA. HOLES 1/4" WITH 51% OPEN AREA. 20 GAUGE COLD ROLLED GENSCO REGISTER BOX W /FLEX COLLAR & OIFF. MODEL COL DC21 OR EQUIV. DETAIL - DIFFUSER CONNECTION Scale: N.T.S. CG E CC A.PX trade: date: ARCHITECTURAL S &C - ARCHITECTURAL 11 -- DRAWNG XREF DATES trade: date: Viice P,� i'151' k' B e.eeM$ `bb ;a 1 Ts7r, 4 APPROVED FOR CONSTRUCTION RECEIVED CITY OF TUK1vILA OCT 3 O 2007 PEHIVIIT CENTER PENDING CITY APPROVAL date: 0 / 25 27 1 ro 0 a 8 W 1< cadd file name: M601 !Beim& vane 10/7_3/07 date of Last revision: 10/22/07 M6.01 2 N) 0 N o 1 s m tz c N o� E C D 0 0 Q Q v E m O m 0 c o 2 CD 0� 0 CC J W Q W � CO U .7, OVA VI = J N 0 s LU o M 1/40 I- II. #64223 - PERMIT ISSUE SEE DETAIL 4 SEE DETAIL 4 SIZING CHART() DIFFUSER EXHAUST AIR FROM OPTIONAL POWER EXHAUST A l NECK SIZE CFM RANGE Q TAP -IN SIZE N (NOMINAL) r _ , A (ACTUAL) 6° x 6° 5 3 /4° x 5 1/4" 0 -125 6 "0 8" x 8" 7 1/4" x 7 3 /4" 126 -225 8 °0 10" x 10° 9 % x 9 3 4° 226 -350 ' 10 "4 12" x 12" 11 3 /4" x 11 3 4" 351 -500 12 "0 14" x 14" 13 1/4" x 13 1/4" ' 501 -675 14 "0 OUTSIDE AIR L OUTS CAS1 105 4' SEE DETAIL 4 DETAIL - RTU-1 UNIT DIMENSION Scale: N.T.S. di" TOP OF CURB MUST BE LEVEL & FLAT (SEE NOTES 1 & 2) 2x6 WOOD BACKING BY 16 GAUGE ROOF CURB - (BY A/C MFG) APPROXIMATE EDGE OF ROOF OPENING L No. 10x /8" SCREW SEAL & MAKE WATERTIGHT fr -------- STOP ROOFING FELT BEFORE CURB LIP SHEETMETAL FLASHING INSTALLED OVER ROOFING FELT. (BY MECH.) AC UNIT BUILT-UP ROOFING CANT STRIP (SEE NOTE 3) ROOF DECK NOTES: 1. GENERAL CONTRACTOR SHALL PROVIDE SHIMS AS REQUIRED TO MAKE CURB LEVEL. MAXIMUM ALLOWABLE SLOPE IS 1/4" PER 10'. 2. TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. 3. ROOF STRUCTURE, ROOF DECK, INSULATION, CANT STRIP & BUILT -UP ROOFING BY GENERAL CONTRACTOR. 4. STRUCTURAL MEMBERS MUST NOT INTERFERE WITH ROOF OPENINGS. 4" WIDE x 16GA SEISMIC RESTRAINTS QUANTITY AND CONNECTION PER TABLE BELOW NOMINAL 2° RIGID INSULATION (SEE NOTE 3) FASTEN ROOF CURB TO DECK PER STRUCTURAL ENGINEER o� o� (3) #12 METAL SCREWS (3) 1/2"0 LAG BOLTS 0 SEE STRAP DETAIL FOR FASTENER TYPE AND SIZE • 2 STRAPS AT EACH LONG SIDE, 2 STRAP AT EACH SHORT SIDE. ® UNIT WEIGHT INCLUDES 200 LBS FOR MECHANICAL DUCT. 0 APPROXIMATE DATA, VERIFY CUT SHEET. DETAIL - CURB W /SEISMIC RESTRAINT Scale: N.T.S. 61)1 II I 4 : 3.938' ■ 4.563" GI q2z) m � CD co m mN m n r- > z 0 12.688' -( 16.625" 21.5' 78.125' CONDENSER COIL T 0 z 0 m z G7 m Cn 2 SEE DETAIL 4 0 Z �- 24.094" 23.25' / 13.5" / 3" 102.344' DETAIL - RTU -2 UNIT DIMENSION Scale: N.T.S. \ At GREASE DRAIN CURB DRAIN )F PLAN FOR LOCATION B.D.D. A SHEETMETAL BY HP B ROOF OPENING OUTSIDE OF CURB GASKET FASTEN FAN TO CURB ANGLE AND FASTENERS NOTE: ROOF OPENING, CURB, CANT STRIP, & ROOFING BY G.C. 1. 'A' = DUCT SIZE, 'B' = 'A' + 2" (OR 'A' + 1" MIN), C = D - 1.5 ", D =FAN BASE O.D., 'B' MUST BE 3" SMALLER THAN 'C' 2. KEC- KITCHEN EQUIPMENT CONTRACTOR. DETAIL - EXHAUST FAN MTG Scale: N.T.S. 2 "X ° CURB 4 0 N ■ ,. 8.75' CONDENSER COIL r I 0 16.625'21.5' 78.094" to I J - r SEE DETAIL 4 c) 0 1 OS TO OS BASE LENGTH 77.875' 23.25' 13.5' 3 DETAIL - RTU-3 UNIT DIMENSION Scale: N.T.S. / 3' 2' -04' t B.D.D. A SHEETMETAL B ROOF OPENING C OUTSIDE OF CURB GASKET FASTEN FAN TO CURB ANGLE AND FASTENERS NOTE: ROOF OPENING, CURB, CANT STRIP, & ROOFING BY G.C. 'A' = DUCT SIZE, ' B = 'A' + 2" (OR 'A' + 1" MIN), C = D - 1.5 ", D =FAN BASE 0.D., 'B' MUST DE 3" SMALLER THAN 'C' 0 , DETAIL - ROOF EXHAUST FAN Scale: N.T.S. 1/2 DUCT SIZE -I. 3" / 1 SHEETMETAL DIFFUSER CAN DIFFUSER LOW PRESSURE INSULAIED FLEX DUCT, THERMAFLEX MK -E MAX 8' LENGTH CRIMP AND BARB TAP -IN EQ. EQ. A - CAN SIZE NOTES 1. CHART BASED ON TITUS MODEL MCD OR KRUEGER MODEL 1244 '4" 2. CFM RANGE & TAP -IN SIZE TYPICAL U.N.O. ON DWGS. PERFORATED METAL %"DIA. HOLES 1/4" WITH 51% OPEN AREA. 20 GAUGE COLD ROLLED GENSCO REGISTER BOX W /FLEX COLLAR & OIFF. MODEL COL DC21 OR EQUIV. DETAIL - DIFFUSER CONNECTION Scale: N.T.S. CG E CC A.PX trade: date: ARCHITECTURAL S &C - ARCHITECTURAL 11 -- DRAWNG XREF DATES trade: date: Viice P,� i'151' k' B e.eeM$ `bb ;a 1 Ts7r, 4 APPROVED FOR CONSTRUCTION RECEIVED CITY OF TUK1vILA OCT 3 O 2007 PEHIVIIT CENTER PENDING CITY APPROVAL date: 0 / 25 27 1 ro 0 a 8 W 1< cadd file name: M601 !Beim& vane 10/7_3/07 date of Last revision: 10/22/07 M6.01 2 N) 0 N o 1 s m tz c N o� E C D 0 0 Q Q v E m O m 0 c o 2 CD 0� 0 CC J W Q W � CO U .7, OVA VI = J N 0 s LU o M 1/40 I- II. #64223 - PERMIT ISSUE SEE DETAIL 4 SEE DETAIL 4 - 2 i■ EXHAUST AIR FROM OPTIONAL POWER EXHAUST A l • 4 Cl r _ , . NE as 7r 8A■ \ \ 1 \ / SUPPLY /\ .. 1 \ \ 1 1 /2' RAD (TYP.) :9 2 RETURN \ . OUTSIDE AIR L L_J ' 2' IDE /- 19 r i f 21 36 21" OUTS CAS1 105 4' SEE DETAIL 4 DETAIL - RTU-1 UNIT DIMENSION Scale: N.T.S. di" TOP OF CURB MUST BE LEVEL & FLAT (SEE NOTES 1 & 2) 2x6 WOOD BACKING BY 16 GAUGE ROOF CURB - (BY A/C MFG) APPROXIMATE EDGE OF ROOF OPENING L No. 10x /8" SCREW SEAL & MAKE WATERTIGHT fr -------- STOP ROOFING FELT BEFORE CURB LIP SHEETMETAL FLASHING INSTALLED OVER ROOFING FELT. (BY MECH.) AC UNIT BUILT-UP ROOFING CANT STRIP (SEE NOTE 3) ROOF DECK NOTES: 1. GENERAL CONTRACTOR SHALL PROVIDE SHIMS AS REQUIRED TO MAKE CURB LEVEL. MAXIMUM ALLOWABLE SLOPE IS 1/4" PER 10'. 2. TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. 3. ROOF STRUCTURE, ROOF DECK, INSULATION, CANT STRIP & BUILT -UP ROOFING BY GENERAL CONTRACTOR. 4. STRUCTURAL MEMBERS MUST NOT INTERFERE WITH ROOF OPENINGS. 4" WIDE x 16GA SEISMIC RESTRAINTS QUANTITY AND CONNECTION PER TABLE BELOW NOMINAL 2° RIGID INSULATION (SEE NOTE 3) FASTEN ROOF CURB TO DECK PER STRUCTURAL ENGINEER o� o� (3) #12 METAL SCREWS (3) 1/2"0 LAG BOLTS 0 SEE STRAP DETAIL FOR FASTENER TYPE AND SIZE • 2 STRAPS AT EACH LONG SIDE, 2 STRAP AT EACH SHORT SIDE. ® UNIT WEIGHT INCLUDES 200 LBS FOR MECHANICAL DUCT. 0 APPROXIMATE DATA, VERIFY CUT SHEET. DETAIL - CURB W /SEISMIC RESTRAINT Scale: N.T.S. 61)1 II I 4 : 3.938' ■ 4.563" GI q2z) m � CD co m mN m n r- > z 0 12.688' -( 16.625" 21.5' 78.125' CONDENSER COIL T 0 z 0 m z G7 m Cn 2 SEE DETAIL 4 0 Z �- 24.094" 23.25' / 13.5" / 3" 102.344' DETAIL - RTU -2 UNIT DIMENSION Scale: N.T.S. \ At GREASE DRAIN CURB DRAIN )F PLAN FOR LOCATION B.D.D. A SHEETMETAL BY HP B ROOF OPENING OUTSIDE OF CURB GASKET FASTEN FAN TO CURB ANGLE AND FASTENERS NOTE: ROOF OPENING, CURB, CANT STRIP, & ROOFING BY G.C. 1. 'A' = DUCT SIZE, 'B' = 'A' + 2" (OR 'A' + 1" MIN), C = D - 1.5 ", D =FAN BASE O.D., 'B' MUST BE 3" SMALLER THAN 'C' 2. KEC- KITCHEN EQUIPMENT CONTRACTOR. DETAIL - EXHAUST FAN MTG Scale: N.T.S. 2 "X ° CURB 4 0 N ■ ,. 8.75' CONDENSER COIL r I 0 16.625'21.5' 78.094" to I J - r SEE DETAIL 4 c) 0 1 OS TO OS BASE LENGTH 77.875' 23.25' 13.5' 3 DETAIL - RTU-3 UNIT DIMENSION Scale: N.T.S. / 3' 2' -04' t B.D.D. A SHEETMETAL B ROOF OPENING C OUTSIDE OF CURB GASKET FASTEN FAN TO CURB ANGLE AND FASTENERS NOTE: ROOF OPENING, CURB, CANT STRIP, & ROOFING BY G.C. 'A' = DUCT SIZE, ' B = 'A' + 2" (OR 'A' + 1" MIN), C = D - 1.5 ", D =FAN BASE 0.D., 'B' MUST DE 3" SMALLER THAN 'C' 0 , DETAIL - ROOF EXHAUST FAN Scale: N.T.S. 1/2 DUCT SIZE -I. 3" / 1 SHEETMETAL DIFFUSER CAN DIFFUSER LOW PRESSURE INSULAIED FLEX DUCT, THERMAFLEX MK -E MAX 8' LENGTH CRIMP AND BARB TAP -IN EQ. EQ. A - CAN SIZE NOTES 1. CHART BASED ON TITUS MODEL MCD OR KRUEGER MODEL 1244 '4" 2. CFM RANGE & TAP -IN SIZE TYPICAL U.N.O. ON DWGS. PERFORATED METAL %"DIA. HOLES 1/4" WITH 51% OPEN AREA. 20 GAUGE COLD ROLLED GENSCO REGISTER BOX W /FLEX COLLAR & OIFF. MODEL COL DC21 OR EQUIV. DETAIL - DIFFUSER CONNECTION Scale: N.T.S. CG E CC A.PX trade: date: ARCHITECTURAL S &C - ARCHITECTURAL 11 -- DRAWNG XREF DATES trade: date: Viice P,� i'151' k' B e.eeM$ `bb ;a 1 Ts7r, 4 APPROVED FOR CONSTRUCTION RECEIVED CITY OF TUK1vILA OCT 3 O 2007 PEHIVIIT CENTER PENDING CITY APPROVAL date: 0 / 25 27 1 ro 0 a 8 W 1< cadd file name: M601 !Beim& vane 10/7_3/07 date of Last revision: 10/22/07 M6.01 2 N) 0 N o 1 s m tz c N o� E C D 0 0 Q Q v E m O m 0 c o 2 CD 0� 0 CC J W Q W � CO U .7, OVA VI = J N 0 s LU o M 1/40 I- II. #64223 - PERMIT ISSUE SEE DETAIL 4 SEE DETAIL 4 HOOD FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE PIPING WEIGHT TYPE QTY. HEIGHT LENGTH QTY. TYPE WIRE GU LOCATION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY LOCATION 1 STAINLESS STEEL (HIGH E 6 16" 20" 3 SCREW IN COMPACT FLUOR NO 10" 16" ©8000 CFM = 762 FPM 1750 - 0.576" 1750 YES 571 LBS. • 875 0.120" 2 STAINLESS STEEL (HIGH E 6 16" 20" 3 SCREW IN COMPACT FLUOR NO 10" _ 24" - 875 0.120" 2 YES • 531 LBS. 600 DEG. 2750 10" 3 STAINLESS STEEL (HIGH E 4 16" 20" 2 SCREW IN COMPACT FLUOR NO RIGHT 0.151" 430 SS WHERE EXPOSED EMS21102 1 UCHT 1 FAN 1 OTHER OUTSIDE YES 541 LBS. 10" 4 STAINLESS STEEL (HIGH E 1 16" 16" 2 INCANDESCENT LIGHT NO RIGHT ANSUL R102 3.0/3.0/3.0 1196 - 0.515" YES 525 LBS. 3 16" 20" 5 430 SS WHERE EXPOSED RIGHT FRONT 0 NO 244 LBS. HOOD NO. MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD CONFIG. TOTAL EXH. CFM BURNER LENGTH RISER(S) TOTAL SUP. CFM RISER(S END TO END ROW WIDTH LENG. DIA. CFM S.P. WIDTH LENG. DIA. CFM S.P. 1 5424 ND-- 2- -PSP -F 10' 0.00" 450 DEG. 1750 10" 16" ©8000 CFM = 762 FPM 1750 - 0.576" 1750 10" 24" - 875 0.120" 430 SS WHERE EXPOSED LEFT FRONT - - - - 10" _ 24" - 875 0.120" 2 5424 ND -2 -PSP -F 10' 0.00" 600 DEG. 2750 10" 26" 2750 - 0.857" 1800 10" : 20" 900 0.151" 430 SS WHERE EXPOSED MIDDLE FRONT 10" 20" 900 0.151" 3 5424 ND -2 -PSP -F 6' 10.00" 450 DEG. 1196 10" 11" ' 1196 - 0.515" 1196 - 10" 28" 1196 0.148" 430 SS WHERE EXPOSED RIGHT FRONT 4 4824 ND -2 -PSP -F 6' 6.00" 450 DEG. 1138 10" 10" 1138 - 0.509 " 1138 10" 28" 1138 0.145" 430 SS WHERE EXPOSED ALONE BACK 5 4224 VHB- -G 8' 0.00" 700 DEG. 1200 10" 10" 600 - 0.075" 0 304 SS 100% ALONE N/A 10" 10" 600 - 0.075" DIM GAS PRESSURE GAS CONNECTION CFM RANGE TONNAGE RANGE FILTERS BDD (Y /N) MODEL BURNER LENGTH BTU LOW DIM MIN MAX "T" (NP MG '1 u0u MIN MAX FILTER SIZE & QTY _ MAX. FILTER VELOCITY - D.750 -G18 COOLING COIL MODULE 27.5 825 7" WC 'R 1 DIM "N" I RC# BTU RANGE (MBH) GAS PRESSURE GAS CONNECTION CFM RANGE TONNAGE RANGE FILTERS BDD (Y /N) MODEL BURNER LENGTH BTU LOW BTU HIGH MIN MAX "T" (NP MIN MAX MIN MAX FILTER SIZE & QTY _ MAX. FILTER VELOCITY - D.750 -G18 18" 27.5 825 7" WC 14" WC 1 3500 8000 10 Ton 25 Ton 16 "x20"x2" (6) ©8000 CFM = 762 FPM - RC# CFM P.D. A B C D BDD (Y /N) CBBDD (Y /N) MD (Y /N) SCREEN (Y /N) DAMPER LINER ' BIRD INSECT MAKE MODEL (Y /N) RC -1 - - 16 - 18 r - 21 21 22.5 22.5 Y - -- - - - -- N -- - - - -- -- - - - - - - - - - - - N REF# UNIT DIMENSIONS CURB /RAIL DISCHARGE OPENING MODEL WEIGHT A B C 0 E F G H J K L N P R S D.750 -G18 1620 LBS 154 54 -3/8 56 -3/8 51-1/8 5-1/4 51-5/8 9-1/2 114 -7/16 35 84 150 -5/8 6 -5/16 22 -3/8 1-1/2 18 REF# FAN OUTLET SIZE STACK SIZE EF -1 11.75x8.5 12x9 110'F NATURAL FAN UNIT N0. . BTU's TEMP. RISE GAS TYPE 4 636884 110'F NATURAL WEEP HOLES 2 "X2" ANGLE NOTES: 1. ROOF OPENING, CURB, CANT STRIP, & ROOFING BY G.C. 2. STANDARD: B= A + 2 ", C= B -1- 3 ", D = C + 11/2" B ROOF OPENING C OUTSIDE OF CURB DETAIL - ROOF CAP DETAIL Scale: N.T.S. OPTIONAL BDD. SEE SCHEDULE POSITION FOR INTAKE OR EXHAUST PER SCHEDULE. 6° 1 3" I /2" HEM 2 "X12" CURB %% MODULAR OUTDOOR DOWN DISCHARGE INDIRECT FIRED HEATER WITH COOLING COIL AND INTAKE HOOD ALL DIMENSIONS ARE NOMINAL AND GIVEN IN INCHES. NIT INFORMATION. a _ DOWNTURN PLENUM DIM "K" COIL ACCESS DOOR DIM "H" DIM " A " CURB OUTER WALL DIM "L" BLOWER/ MOTOR ACCESS DOOR ROOF OPENING 2" SMALLER THAN CURB DIMENSION NOTE: 1. SEE SCHEDULE IN DWG SHT M7.01 DETAIL - MAKE-UP AIR UNIT Scale: N.T.S. 1" FLANGE FOR DUCT CONNECTION ACCESS FOR VOLUME DAMPER ADJUSTMENT SCREW (SOCKET HEAD SCREW REQUIRES 3/16 ALLEN WRENCH). TO CLOSE DAMPER: TURN SCREW CLOCKWISE. TO OPEN DAMPER, TURN SCREW COUNTERCLOCKWISE. (NOTE: DAMPER ASSEMBLIES LONGER THAN 30" HAVE TWO OBD - ADJUSTMENT MUST BE MADE AT BOTH ENDS) 7" NOM 12" MAX. `sue OPPOSED BLADE VOLUME DAMPER 1" FLANGE FOR CONNECTION TO HOOD 4.5" NOM EXTENDS BELOW TOP OF HOOD U.L. FIRE DAMPER (INSIDE) WITH 212 DEG. FUSIBLE LINK DETAIL - SUPPLY AIR VOLUME & FIRE DAMPER ASSEMBL Scale: N.T.S. Y DISCHARGE OPENING 1" NPT CONNECTION FOR SS PITCHED DRAIN PAN COIL CONNECTIONS AIRFLOW 1 20 IN HIGH EQUIPMENT CURB J BY HP SEE PLAN FOR BDD LOCATION SEE M3.01 ROOF PENETRATION SEE PLAN FOR BDD LOCATION WEATHERPROOF FLEX CONNECTION P.O.C. SEE ROOF PLAN FOR LOCATION 4' -0" MIN. NOTES: 1. SEE ROOF PLAN SHEET M3.01 FOR ALL EXHAUST FAN LOCATION 2. KEC - KITCHEN EQUIPMENT CONTRACTOR. STACKHEAD UTILITY EXHAUST J FAN INSTALL ON 4 "x4" SLEEPERS BY G.C., SEE Q ROOF SLEEPERS BY KEC, SEE DRILL WEEP HOLE IN FAN HOUSING LOW POINT, RECOAT METAL AT HOLE. "MASON" BR TYPE ISOLATION MOUNT OR SSLFH SEISMIC SPRING ISOLATORS DETAIL - UTILITY SET EXHAUST FAN (EF -1) Scale: N.T.S. 0 Ev-- SERVICE DISCONNECT SWITCH DIM "T" INDIRECT FIRED MODULE = SLOPED FILTER INTAKE DIM "G" DIM "F" GAS FIRED MAKE -UP AIR UNIT ti 0 3.00" 17 10.00" - 10.00" 24.00" HOOD INFORMATION HOOD INFORMATION co A EXHAUST 4' PVC VENT TERMINAL WITH MESH PROTECTIVE SCREEN INSIDE EXHAUST VENT TERMINAL FLASHING ROOF NOTES: 1. DETAIL FOR GAS FIRED WATER HEATER. 2. AIR OUTLET OPENING SHALL BE SHALL BE 10 FT AWAY FROM AIR INTAKE OPENING. DETAIL - EXHAUST /INTAKE VENT DETAIL Scale: N.T.S. B INTAKE 4' PVC 45' WITH DIVERTER PLATE AND ADAPTER SCREEN INTAKE VENT TERMINAL FLASHING ROOF 4' PVC FROM HOT WATER HEATER N 10.00" 10.00" HOOD - H -5 (DISHW) 24.00" 4' 48.00" 8' 0.00" H -5 PLAN VIEW - 8' 0.00' LONG 4224VHB -G 16.00" HOOD - H-1L (MAIN) U.L. LISTED SCREW IN COMPACT FLUOR 30.00" 60.00" 6.00" 13.00" 1-8 -0:00" DISHWASHER HOOD 10.00" 0 1`-- 24410L__.' 3f 0.00" H - 1 PLAN VIEW - 10' 0.00' LONG 5424ND 10.00" ,1' 24.00" HOOD - H -2M (MAIN) U.L LISTED SCREW IN COMPACT FLUOR X61 10.00" - Q 10.00" ,le- 20.00" 60.00" 30.00" ,1' 26.00" 6.00" 10.00" k 60.00" 10' 0.00" 1' 8" 60.00" H - 2 PLAN VIEW - 10' 0.00' LONG 5424ND - Z PSP - F DETAIL - HOOD #1, 2, 3, 4 & 5 Scale: N.T.S. H-4 PLAN VIEW - 6' 6.00' LONg 4$Z41I-2 -PSP -F 6' 6.00" 3' 9" 10.00" 0 ,4' 30.00" 10.0000' --- 6.00" 10.00" 10.00" 41.00" IO.aoao 47.00" U.L LISTED SCREW IN COMPACT FLUOR 0 0 HOOD - H -4 10.00" 11.00" ,j' ,' HOOD - H- 3R(MAIN) �U.L LISTED SCREW IN COMPACT FLUOR 28.00" -- 41 00" 6' 10.00 "Nom. /6' 10.00 "OD 3.00" 47.00" trade: date: ARCHITECTURAL S&C - ARCHITECTURAL TI - H -3 PLAN VIEW - 6' 10.00' LONG 5424ND -2 -PSP -F y O /12.00" - 3.00" LIGHT AND FAN SWITCHES DRAWING XREF DATES trade: date: _. _ 14. I � - , a.1e'7e �y"t8�d6,. e 1 r; :- r , , r- , ,iT T fN n � PENDING CITY APPROVAL APPROVED FOR CONSTRUCTION RECEIVED CITY OF TUKwiu OCT 3 0 2007 PEHMIT CENTER appr date: L / re E V V 9 0 e E 0 LU Z l ip 1 / 0 --3 / 6 T d ium iption 1.1 1■ 11111C gal N ° m q 0 a Da N M � c i .rte vi m 0 � Q: O • O W CC M z z O Z C7 W W h 2 W uu, NO ocN 0 � J 11-171- Q Z ` co W CO U Er I . ON O VA = J EA 9 en � I-- date of last revision: 10/22/07 M6.02 cadd file name: M602 10/22/071 GRIT]. #64223 - PERMIT ISSUE EMS HANGING ANGLE 3" STANDOFF IXHAUST RISER 16" U.L. CLASSIFIED BAFFLE -TYPE GREASE FILTERS GREASE DRAIN WITH REMOVABLE CUP EQUIPMENT BY OTHERS SECTION VIEW - MODEL 5424 -ND -2 WITH PSP ACCESSORY HOOD # 1,2,3 & 4 \_ DRAIN ALUMINUM MESH FILTER EQUIPMENT BY OTHERS 100W VAPORPROOF INCANDESCENT LIGHT EXHAUST RISER FULL LENGTH ANGLE (TYPICAL) SECTION VIEW - MODEL 4224 -VH1 WITH FULL PERIMETER GUTTER HOOD # 5 SUPPLY RISER WITH VOLUME DAMPER 23.5% OPEN STAINLESS STEEL PERFORATED PANEL PRESS FIT UNTIL PANEL FACES ARE FLUSH WITH HOOD AND POP RIVET OR SCREW PANELS TO C— CHANNEL TOP SEAM ON HOOD INSTALLER TO — FASTEN WRAPPER TO FACTORY C— CHANNEL COMPLETED WRAPPER ASSEMBLY FACTORY C- CHANNEL NOTCH REQUIRED WHERE SEAM MEETS WRAPPER FIG.3 TOP HOOD SEAM DETAIL HOOD OPTIONS WRAPPER FRONT CANOPY HOOD — WRAPPER END SLIDE SIDE PANEL — BETWEEN WALL AND "L° BRACKET. POP RIVET OR SCREW SIDE PANEL TO WALL "L° BRACKET. HOOD OPTION N0. H -1 L BACKSPLASH 80.00" HIGH X 120.00" LONG 430 5S FIELD WRAPPER 17.00" HIGH FRONT, LEFT, H -2M BACKSPLASH 80.00" HIGH X 120.00" LONG 430 SS FIELD WRAPPER 17.00" HIGH FRONT, H---3R BACKSPLASH 80.00" HIGH X 94.00" LONG 430 SS FIELD WRAPPER 17.00" HIGH LEFT, H -4 BACKSPLASH 80.00" HIGH X 90.00" LONG 430 S5 FIELD WRAPPER 17.00° HIGH FRONT, LEFT, RIGHT, H -5 FIELD WRAPPER 17.00" HIGH FRONT, LEFT, RIGHT, SCREW OR POP -RIVET HEIGHT WRAPPER FIG.1 WRAPPER DETAIL INSIDE OF SIDE PANEL FIG.2 WALL ANGLE BACKSPLASH KINK OVERLAPPED BY ADJACENT SECTION FACTORY MOUNTED r C- CHANNEL SIDE OF HOOD TOP OF HOOD FASTEN "L" BRACKET TO WALL WALL "L" BRACKET DRAWING XREF DATES date: I trade: date of last revision: 10/22/07 trade: ARCHITECTURAL S&C — ARCHITECTURAL Ti -- date: CODE COMPLIANCE A D E 1-11, � a } -., � �1 ^ S h�k Ali {bs� APPROVED FOR CONSTRUCTION RECEIVED CITY OF TUKWILA OCT 3 0 2007 PEHIVIIT CENTER PENDING CITY APPROVAL date: [O cadd file name: M603 - -.L 'in 0 0 1- ti z 0 SCREW HOLES AT 2 O'CLOCK AND 8 O'CLOCK ANSUL PULL STATION DETAIL FACTORY PIPING FIELD PIPING ANSUL R -102 FIRE SYSTEM SPECIFICATIONS APPLIANCE PROTECTION NOZZLE TYPICAL ANSUL R--102 SYSTEM LAYOUT 1 /2" CONDUIT STRAIGHT UP TO ABOVE CEIIJNG LINE, NO OFFSETS OR BEND 4" STANDARD ELECTRICAL OCTAGON BOX 5' ABOVE FINISHED FLOOR OR IN ACCORDANCE WITH LOCAL CODE. PLENUM N NOZZLE NOTE HEIGHT OF PULL STATION SHOULD BE DETERMINED IN ACCORDANCE WITH AUTHORITY HAVING JURISDICTION. THE RESTAURANT FIRE SUPPRESSION SYSTEM SHAD_ BE THE PRE- ENGINEERED TYPE WITH A AXED WITH UNDERWRITERS NOZZLE AGE NT, T DN TRIBU1 ON NETWORK. IT SHALL BE LISTED (UL) THE SYS SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS UNE SHUT -OFF APPUCATIONS. THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM ACETATE -BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIQUID AGENT HANDUNG AND USAGE. THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE UNK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM. THE FUSIBLE UNK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ UNKAGE ASSEMBLY. DECTECTOR OEM RELEASE/ BRACKET ASSEMBLY REMOTE MANUAL PULL STATION REMOVABLE STAINLESS STEEL SERVICE DOOR AGENT TANK - FIELD PIPE DROPS AS SHOWN - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY UNE - MINIMUM 72 INCHES OF AGENT UNE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. 1- 14.0000" --1-- 16.0000" --- 15.0000" 12.0000" + 12.0000" LEGEND - FIRE CABINET ANSUL SYSTEM 1 A 1.5 GALLON TANK 1B 3 GALLON TANK 2 OEM AUTOMAN RELEASE 3 OEM REGULATED RELEASE 4 OEM REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX UQUID AGENT (1.5 GAL) 7 CARTRIDGE (101 -20) 8 CARTRIDGE (101 -10) 9 CARTRIDGE (101 -30) 9A CARTRIDGE (LT --A- 101 -30) 9B DOUBLE TANK CARTRIDGE 10 TEST UNK 11 DOUBLE MICROSWITCH 12 HOSE ASSEMBLY 1100 DUCT NOZZLE (430913) 2W DUCT NOZZLE (419337) 13.0000" - 13.0000" 3.I0CQ" 12.0000" 10.0000" - 14.0000" FIRE SUPPRESSION SYSTEM 1W NOZZLE ASSEMBLY (419336) 1F NOZZLE ASSEMBLY (419333) 1N NOZZLE ASSEMBLY (419335) 1/2N NOZZLE ASSEMBLY (419334) 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY (419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET 29 LOW TEMP FUSIBLE UNK 30 HIGH TEMP FUSIBLE LINK MGV MECHANICAL GAS VALVE EGV ELECTRICAL GAS VALVE 34 REMOTE MANUAL PULL STATION S SWIVEL ADAPTOR 24.0000" NOZZLE EXTENDS 6 INCHES BELOW HOOD STEAMER 32.00" L X32.00" D NO PROXIMITY RATING OVEN 32.00" L X32.00" D HIGH PROXIMITY HOOD # 4 L 71 11 11 11 11 11 11 II II 11" 11 II 1L_ 0 _--- Q____ I 3. 0 --- 14.0000" -L 16.0000" —L 15.0000" -I 12.0000" 1 12.0000" L 13.0000" __l_ 13.0000" 1 12.0000" 1 10.0000" HOOD # 1 � I II 1 1 11 II 1 1 I I 0.1745" HOOD # 3 trade: RANGE -SHELF (20 "MIN FROM GRATE) RANGE -SHELF (20 "MIN FROM GRATE) GAS RADIANT CHARBROILER - S GRIDDLE FL) OVEN 36.00" L X24.00" D 36.00" L X24.00" D 60.00" L X24.00" D 24.00" L X24. 0 0" D 38.00" L X24.00" D HIGH PROXIMITY HIGH PROXIMITY HIGH PROXIMITY HIGH PROXIMITY HIGH PROXIMITY ARCHITECTURAL S&C - ARCHITECTURAL T1 -- EXTRA QUICK SEALS TO BE PLUGGED IN FACTORY date: PENDING CITY APPROVAL date: APPROVED FOR CONSTRUCTION RECEIVED CITY OF f UK v!L A OCT 3 0 2007 PEHMIT CENTER approve date of last revision: 10/22/07 cadd file name: ROOF TOP UNITS MUA # AC # MAKE AREA SERVED MAKE MODEL NOM. TONS DOWNFLOW/ HORIZONTAL FACTORY CURB (YIN) ENTERING AIR CONDENSING TEMP °F ARI EFFICIENCY COOHNG CAP, MBH OUTSIDE AIR CFM SUPPLY FAN DATA ELEC. HEAT (KW) GAS HEAT, MBH SAT SETPT ( °F) ELEC. HEAT (KW) WINTER ELECTRICAL WEIGHT _LBS) FILTERS REMARKS DB WB EER IPLV TOTAL SENSIBLE CFM ESP . RPM BHP QTY. MHP DESIGN °F IN OUT REQD. OUT DESIGN °F VOLTS /PH MCA AMPS QTY EFF SIZE EF -1 1 ROOF KITCHEN HOOD 1 CAPTIVE AIRE • UTILITY BI24CARM 1 4,500 1.85 948 1, -- — — — 3 4.7 , 940 26 X 26 1, 2 EF -2 1 , KITCHEN HOOD 2 CAPTIVE AIRE UP —BLAST NCA16HPFA MUA -1 KITCHEN CAPTIVE AIRE RTU-1 17 PARTIAL DINING . AAON RM -020 -3 18 DOWNFLOW Y 80.19 63.79 100 11.5 NA 227.37 196.04 2,180 6,300 1.75 950 4.06 1 7.5 N/A 270 218.7 218.7 56 N/A 24 460/3 52 47 4100 6 30% , 24"x24 "x2" 1, 2, 3, 5, 7 RTU -2 s PARTIAL DINING AAON RN —A13 -3 13 DOWNFLOW Y 83.10 64.76 100 10.6 NA 158.4 137.35 2,160 3,705 1.5 1569 2.78 1 5 180 146 146 56 N/A 24 460/3 32 30 2700 6 30% 24 "x24 "x2" 1, 2, 3, 5, 7 RTU -3 _ KITCHEN AREA AAON RN -007 -3 7 DOWNFLOW Y 90 67 100 10.3 NA 98.47 92.8 2,650 2,650 1.5 1745 _ 1.7 1 3 s 180 146 146 56 N/A 24 460/3 25 22 r 2000 4 30% 24 "x24 "x2" 1, 2, 3, 5, 6 MAKE -UP AIR UNIT SCHEDULE MUA # AREA SERVED MAKE MODEL NOM. TONS DOWNFLOW/ HORIZONTAL FACTORY CURB (YIN) ENTERING AIR CONDENSING TEMP °F ARI EFFICIENCY COOLING CAPCITY OUTSIDE AIR CFM SUPPLY FAN DATA GAS. HEAT MBH SAT . SETPT ('F) ELEC. HEAT (KW) WINTER ELECTRICAL WEIGHT (LBS) FILTERS REMARKS DB WB EER IPLV 'TOTAL, MBH SENSIBLE CFM ESP RPM BHP QTY. MHP IN OUT REQD. OUT DESIGN °F VOLTS /PH MCA AMPS QTY SIZE 4, 5, 6, 7, 8, 9, 10, 11 EF -1 1 ROOF KITCHEN HOOD 1 CAPTIVE AIRE • UTILITY BI24CARM 1 4,500 1.85 948 1, -- — — — 3 4.7 , 940 26 X 26 1, 2 EF -2 1 , KITCHEN HOOD 2 CAPTIVE AIRE UP —BLAST NCA16HPFA MUA -1 KITCHEN CAPTIVE AIRE A3— D.750 —G18 17 HORIZONTAL Y 90 67.0 90 2.3 _ 204 24 X 24 5,884 5,884 0.55 949 DISHWASHER HOOD 1 7.5 181 148.4 134 0.75 N/A 21 460/3 24 11 3510 6 16 "x20 "x2" 1, 2, 4, 5 140 17.5 X 17.5 1, 3 EF -4 1 ROOF TOILET s DOWNBLAST GB -091 -3 — 500 t5 1366 0.25 — — — — 3/4 7.2 120/1 75 n 1, 3, 4 FAN SCHEDULE . FAN NUMBER QTY LOCATION SERVED MAKE TYPE MODEL CLASS PERFORMANCE DATA PERFORMANCE (FUTURE) HP FLA VOLTS/ PHASE WGT. LBS. ROOF OPENING REMARKS CFM S.P. RPM BHP CFM S.P. RPM BHP INPUT VOLT. F.L.A. RH--1 PATIO DETROIT HL2 -20 -65 50000 120/1 4.8 4 --- 13' -- 0" 150 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 EF -1 1 ROOF KITCHEN HOOD 1 CAPTIVE AIRE • UTILITY BI24CARM 1 4,500 1.85 948 1, -- — — — 3 4.7 460/3 940 26 X 26 1, 2 EF -2 1 ROOF KITCHEN HOOD 2 CAPTIVE AIRE UP —BLAST NCA16HPFA — 2,334 1.65 s 1333 — — — — 1.5 2.3 460/3 , 485 24 X 24 1, 2 EF -3 1 _ ROOF DISHWASHER HOOD CAPTIVE AIRE UP —BLAST DU5OHFA -- 1,200 0.75 _ 1336 _ — — —_ — 0.5 8.1 208/1 140 17.5 X 17.5 1, 3 EF -4 1 ROOF TOILET GREENHECK DOWNBLAST GB -091 -3 — 500 t5 1366 0.25 — — — — 3/4 7.2 120/1 75 14.5X14.5 1, 3, 4 GAS FIRED RADIANT HEATER SCHEDULE C.U. # DC# LOCATION MAKE MODEL LENGTH FT DXFC# RH # LOCATION MAKE MODEL HEATING MBH ELECTRICAL FLUE SIZE COMBUSTION AIR SIZE LENGTH WEIGHT LBS. WEIGHT VOLTAGE FLA. DC -1 REMARKS MARS 60CHS 5 INPUT VOLT. F.L.A. RH--1 PATIO DETROIT HL2 -20 -65 50000 120/1 4.8 4 --- 13' -- 0" 150 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 RH -2 PATIO DETROIT HL2 -20 -65 50000 120/1 4.8 4 — , 21' -- 7" 150 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12 D.X. FAN COIL SCHEDULE (SPLIT SYSTEM) C.U. # DC# LOCATION MAKE MODEL LENGTH FT DXFC# AREA SERVED MAKE MODEL MATCHING COND. UNIT COOLING, MBH FAN PERFORMANCE DATA WEIGHT ELECTRICAL FILTERS CFM. WEIGHT VOLTAGE FLA. DC -1 REMARKS MARS 60CHS 5 ENT. DB /WB TOTAL , SENS. CFM OA CFM ESP MHP HEAT KW VOLTS /PH FLA MCA r QTY. SIZE DXFC -1 PARTY ROOM TRANE 2TEC3F24A1 CU -006 80/67 24 17 800 280 0.5 1/3 5 208/3 37 1 20x20x1 150 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 DOOR CURTAIN SCHEDULE C.U. # DC# LOCATION MAKE MODEL LENGTH FT KW SEER. FAN ELECTRICAL VOLTS /PH CONT. VOLTAGE DBA WEIGHT 2TWB3024A REMARKS CFM. H.P. VOLTAGE FLA. DC -1 MAIN DOOR S MARS 60CHS 5 2 4000 1 208/3 4 — 69 110 1, 2, 3 s SPLIT SYSTEM CONDENSING UNIT SCHEDULE C.U. # MAKE MODEL DXFC SERVED MBH ELECTRICAL EER SEER. WEIGHT (LBS) REMARKS VOLTS /PH MCA CU -01 TRANE 2TWB3024A DXFC -1 2 208/3 9 13 263 1, 2, 4, 5, 6 CU -02 MCQUAY ACZ020A MUA -1 211.1 460/3 41 11.5 2800 1, 2, 4, 5, 6 1: WIRING AND DISCONNECTS BY E.C. SINGLE POINT POWER CONNECTION. 2: RETURN SMOKE DETECTORS SUPPLIED & INSTALLED BY M.C. ALL FLS WIRING AND INTERLOCKS BY FLS CONTRACTOR. 3: UNIT PROVIDED WITH 32" HIGH ROOF CURB 4: UNIT PROVIDED WITH 44" HIGH ROOF CURB 5: UNIT PROVIDED WITH STAGED GAS CONTROL 6. WITH STAILESS STEEL HEAT EXCHANGER 7. WITH ALUMINUM HEAT EXCHANGER 1: E.C. TO PROVIDE ALL POWER WIRING AND DISCONNECTS (U.N.O.), SINGLE POINT POWER CONNECTION (U.N.O.) (THIS NOTE APPLIES TO ALL EQUIPMENT IN THE UST ABOVE) 2: AUTOMATIC MOTOR STARTER WITH HOA SWITCH SHALL BE PROVIDED AND INSTALLED BY E.C., COIL CIRCUIT POWERED BY E.C., COIL VOLTAGE TO BE 120V. 3: MANUAL STARTER W /OVERLOAD PROTECTION SHALL BE PROVIDED AND INSTALLED BY E.C. 4: INTERLOCK WITH EF -1, EF -2 AND EF -3 5 PROVIDE UNIT WITH STAINLESS STEEL HEAT EXCHANGER. 1: E.C. TO PROVIDE ALL POWER WIRING AND DISCONNECTS (U.N.O.), SINGLE POINT POWER CONNECTION (U.N.O.) (THIS NOTE APPLIES TO ALL EQUIPMENT IN THE UST ABOVE) 2: AUTOMATIC MOTOR STARTER WITH HOA SWITCH SHALL BE PROVIDED AND INSTALLED BY E.C., COIL CIRCUIT POWERED BY E.C., COIL VOLTAGE TO BE 120V. 3: MANUAL STARTER W /OVERLOAD PROTECTION SHALL BE PROVIDED AND INSTALLED BY E.C. 4. RUNS CONTINUOUSLY DURING OPERATING HOURS. 1. WIRING AND DISCONNECT BY E.C. SINGLE POINT POWER CONNECTION. 2. MANUAL STARTER W /OVERLOAD PROTECTION SHALL BE PROVIDED AND INSTALLED BY E.C. 3. DBA IS MEASURED IN FREE AIR 10 FEET FROM THE NOZZLE. 1. WIRING AND DISCONNECT BY E.C. SINGLE POINT POWER CONNECTION. 2. P.C. TO PROVIDE CONDENSATE DRAINAGE AND FIELD VERIFY IF CONDENSATE PUMP IS REQUIRED 3. E.C. TO PROVIDE 115V POWER TO CONDENSATE PUMP IF REQUIRED 8. PROGRAMMABLE THERMOSTAT SHALL BE PROVIDED AND INSTALLED BY CONTROL CONTRACTOR (M.C.) SETBACK AND SHUT — OFF — AUTOMATIC CONTROL SHALL HAVE A MINIMUM 7 DAY CLOCK AND BE CAPABLE OF BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK, BE CAPABLE OF RETAINING PROGRAMMING AND TIME SETTING DURING LOSS OF POWER FOR A PERIOD OF AT LEAST TEN HOURS AND INCLUDE 4. HANG WITH MASON TYPE "HD" NEOPRENE HANGERS. AN ACCESSIBLE MANUAL OVERRIDE, OR EQUIVALENT FUNCTION, THAT ALLOWS TEMPORARY OPERATION OF THE SYSTEM FOR UP TO TWO HOURS. 5. LOW VOLTAGE CONTROL WIRING BETWEEN DXFC AND CONDENSING UNIT BY M.0 CONTROLS CONTRACTOR 9. COOLING CAPACITY RATED AT 80 F DB /67 FWB AIR ENT'G INDOOR COIL & 95 FDB AIR ENT'G OUTDOOR COIL 6. BAS TO MONITOR CONDENSATE ALARM SWITCH. 10. PROVIDED WITH 100% OSA ECONOMIZER. OSA DAMPER TO FULLY CLOSE WHEN UNIT IS OFF. 7. UNIT PROVIDED WITH CONDENSATE OVERFLOW SENSOR. SENSOR SHALL DISABLE THE UNIT. 1. WIRING AND DISCONNECT BY E.C. SINGLE POINT POWER CONNECTION. 2. LOW AMBIENT KIT PROVIDED AND INSTALLED BY REFRIGERANT PIPING CONTRACTOR. PENN P66 SERIES. 3. FASTEN TO FLOOR ON MASON TYPE "W" WAFFLE PAD WITH BOLT ISOLATION BUSHINGS. 4. EER AND SEER RATINGS PER ARI 210 /240 —1994 5: OPTIONS INCLUDE CRANKCASE HEATER KIT, AND TSTAT. 6: LOW VOLTAGE CONTROL WIRING BETWEEN DX FAN COIL AND CONDENSING UNIT BY M.C. CONTROLS CONTRACTOR MAX. 2 -90° ELBOWS. MAX. 20' LENGTH. CODE REQUIRED DISCONNECT SHALL BE PROVIDED AND INSTALLED BY E.C. LINE VOLTAGE TIMER IS PROVIDED BY M.C. AND INSTAI I FD BY E.C. LABEL FOR TIMER IS PROVIDED AND INSTALLED BY M.C. STANDARD EQUIPMENT: REFLECTORS, REFLECTOR END CAPS, MANUAL GAS SHUT —OFF VALVE, HANGER CLAMPS & CHAINS. OPTIONS INCLUDE: 12 HOUR WALL TIMER, CHAIN. 1: 2: 3: 4: 5: 6: 7: INSTALL TRANSVERSE CABLE RESTRAINT /BRACE TO PREVENT SWAY. 8. UNIT USES NATURAL GAS. 9. TWO STAGE GAS VALVE AT 100% AND 65 %. 10. UNIT USES STRAIGHT TUBE. 11. UNIT USES U —TUBE. NOT APPROVED FOR CONSTRUCTION trade: ARCHITECTURAL. S &C — ARCHITECTURAL TI — DRAVVIVG XREF DATES date: trade: date: i i CaaE. Cil4PLIANCE !i'i' JEC i r 0I PENDING CITY APPROVAL APPROVED FOR CONSTRUCTION RECEIVED CITY OF TUKVJILA OCT 3 0 20[i r PERMIT CENTER date: 14717 ,3107 F E V n m to a ■ M move& 10/24i08 / 'Vi3la 7 a on c4r .4 iniiii 2.-- /PT h al cr, Who 43 N ill% s P dpi m a Ulna a a ..._ in igt -c CO .4 1- - N • k a lea �o N- • 0 LT. 0 0 Ce J W Q W � W W ..O� o U tan I -) 0 5 re2 date of last revision: io/zz /o7 M7.01 U) 0w WM F m 0 Z 0 w w w w a (n cadd file name: M 701