Loading...
HomeMy WebLinkAboutPermit M07-232 - WESTFIELD SOUTHCENTER MALL - BORDERS BOOKSBORDERS BOOKS 2437 SOUTHCENTER MALL M07 -232 Parcel No.: 6364200010 Address: Suite No: DESCRIPTION OF WORK: MECHANICAL FOR NEW TI Cityf Tukwila 2437 SOUTHCENTER MALL TUKW Tenant: Name: BORDERS BOOKS Address: 2437 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: MICHAEL A CHIODINI Address: 1401 S BRENTWOOD BL , ST LOUIS MO Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA Contractor License No: MERITMI163CM Value of Mechanical: 200,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 4 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC-10 /06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT IOUIPMENT TYPE AND QUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 314 725 -5588 Phone: 425 883 -9224 Expiration Date: 06/01/2009 M07 -232 03/17/2008 09/13/2008 Fees Collected: $1,896.75 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 82 Thermostat 13 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 11 M07 -232 Printed: 03 -17 -2008 Permit Center Authorized Signature: The granting of construction or th Signature: Print Name: doc: IMC-1 O/06 •e perfo City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us e3 Ala I hereby certify that I have read and - - ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied does not pr ce of work. th, whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulatinc authorized to sign and obtain this mechanical permit. Permit Number: M07 -232 Issue Date: 03/17/2008 Permit Expires On: 09/13/2008 Date: 0 114 Date: U(( 1 �� b This permit shall become null and void if the work ' - of commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -232 Printed: 03 -17 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 2437 SOUTHCENTER MALL TUKW BORDERS BOOKS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -232 ISSUED 10/31/2007 03/17/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until fmal inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tulcwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: ** *FIRE DEPARTMENT CONDITIONS * ** 7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 8: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 9: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 10: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 11: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 12: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 14: An electrical permit from the City of Tulcwila Building Department Permit Center (206 - 431 -3670) is required for this project. 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and doc: Cond -10/06 M07 -232 Printed: 03 -17 -2008 #2051) City of Tukwila 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -232 Printed: 03 -17 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the • • ormance of work. Signature: Print Name: doc: Cond -10/06 Date: M07 -232 Printed: 03 -17 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hap://wwiy.ci.tulovila.wa.us SITE LOCATION 1 ""! ' MM4 Co Assessor's Tax No.: ! 1A;2 "�i � Site Address: ��S 1 5 —�� � �� pusiin C ` ����// // suite Number: Floor: Tenant Name: /r6 / - `i .�'n l�l New Tenant: Yes ❑ .. No Property Owners Name: Mailing Address: 1/64/ 11#45/99 $i'j: / q City Stan Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 1114114P-- al bt J I /� �Y Day Telephone: 4- 1,�� -�j5 �D� J I Mailing Address: 'bI S• 92.z �jVP 4• - L i 7I No (0.3 I+4 E -Mail Address: MC/4 I teili 10) 0 .awk GENERAL' CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Expiration Date: Contractor Registration Number: ARCHITECT OF RECORD -All plans must be wet stamped by Architect of Record Company Name: Mailing Address: ��/( ' I / �jJ/ y � J Contact Person: II t J/(17A b--F- A. 61410D I' v I E -Mail Address: 14 1CIVOI el • c ENGLNEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: S Mailing Address: .7 O M7 sf Contact Person: P4// E -Mail Address: IoDINI cc-1 Q A pncCariuns Fumtr. AprLca 1)n Lme? -9u* • Pcmn Arr42,10n dnc R.•.iud: 9.2004 eta Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** �A� Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. 1 Project No. (For office use only) City State tp Fax Number: 51 — � 341 State tif Zip 3 4 City State Zip Day Telephone: iz G ✓- 558e Fax Number: '9)4 125 - -134 '// � state // ,p Day Telephone: �`l/ — S 7�� Fax Number: Pzwe I of 6 BUILDING PERMIT INFOR TION - 206 - 431 -3670 Valuation of Project (contractor's bid price): S I MII, Existing Building Valuation: S Scope of Work (please provide detailed information): 1/ / .2Z pV GJI7 w/d rn zt Cerfirt l_ 7 " _ . Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below lu Floor 2 ° a: Floor'r' 3 - Floor ' = ' Floors :. -, ,Basement``= ` Accessor Structure' • Attached Garage Detached- Garage Attached; Carport D etached Carport •.Co Uncovered -Deck •' Existing Interior Remodel Addition to Existing Structure New 4 - Type of Construction per X1-8 Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 13 inches and overhangs greater than 13 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ ....... No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: X ......Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No IJ 'Ives', attach list of materials and storage locations on a separate 8 -1 /2 "x II " paper including quantities and Material Soler): cite Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. t • Q ApplicaNnnc Forms- Applicatinnx t In Line 3 - 200n - Pemtit - rpnlienin,n.tiuc 6r) X . No If yes, a separate permit and plan submittal will be required. Pale 2 of 6 PUBLIC WORKS PERfMIT INFORiMATION - 206 -433 -0179 Scope of Work (pl e �ei prode detailed e,,/ ��tformation): 1ek / r)1 �� W ter District Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District Tukwila 0... ValVue ❑ .. Renton ...Sewer Use Certificate ❑...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public Water Meter Retitnd Billing: Name: Mlailir.t_ Address: Please refer to Public Works Bulletin #1 for fees and estimate sheet. SI ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 0:'Applic.ti.,ns Enn, - 1ppiicathms Un Lin. 3 -2M)n • Prrmit Appiicntu.n act: Revis.J: 9.2906 en Call before you Dig: 1- 800 -424 -5555 ❑ .. I- Iighline WO # WO # WO # Private Private ❑ .. Geotechnical Report ❑ .. Maintenance Aereement(s) Igcl2Me ❑ .. Renton ❑ .. Seattle ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Richt -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding 0... Deduct Water Meter Size ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing. Address: City State Zip Day Telephone: City St:ne Zip P•tee3of6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser Ea 3 - 15 HP /500.000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 15 HP!1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Flood and Duct Emergency Generator 50- HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment i I Air Handling Unit <10.000 CFM Incinerator — Commilnd MECHANICAL PERMIT INR'VIATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION at f F "' 1") • Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ te:4 is Scope of Work (please provide detailed information): /4 001 , GtJ� 4 �a izeze, r. Use: Residential: New .... ❑ Replacement 2222 ❑ Commercial: New .. Replacement .... ❑ ' Fuel Type: Electric ❑ Gas... Indicate type of mechanical work being installed and the quantity below: Q:' Appl;cstions Fa rns- Appiiatians Im Linc 3- 236 . Pcrnit Appiicarion.:k�c RI'iscd: 9-2004 hit Recla Other: Paw: 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: -Qty Fixture Type: Qty Bathtub or combination bath/shower O Drinking fountain or water cooler (per head) q !�' Wash fountain 0 Gas piping outlets �+py� { Bidet D Food -waste grinder, commercial Q Receptor indirect waste f c3 Clothes washer. domestic I) Floor drain Sinks Dental unit, cuspidor 11 Shower, single head trap Urinals Dishwasher, domestic, with independent drain ' Lavatory Water Closet 5 Building sewer or trailer park sewer Rain water system — per drain (inside building) 0 Water heater and/or vent i Additional medical gas inlets/outlets — six or more O Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type crease interceptors Repair or alteration of water piping and/or water treating equipment O Repair or alteration of drainage or vent piping r l J Medical gas piping system serving one to five inlets:outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION O f' . Company Name: i Mailing Address: City State Zip Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): S lei. / COO Valuation of Gas Piping work (contractor's bid price): S l(7 ( 'M ) Scope of Work (� e provide detailed information): �1\ — t : PA j � f S1 r A 1/4A11.., r-k (" r_ Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: St/ Q. - Applieauons 1orn.. Applm:umns () n L :ne.i- 2 • i -;nut dpplie311.1. t: 9. 2(.0” nh Paizc5of( PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justiciable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER , f � 1 AUTHO Z D AGENT: Signature: G��`Yti Print Name: /., / A. ( i ?c MN iV� Mailing Address: 5 Pit%Ftt�//i►� Date Application Accepted: iolk (); Applicuiun. Fern *Appii:atinn. )n Linc 3- '066 . Femur ? ppiicatiun.dre Re•:ised: 9 -7006 bh Date: 12j 47 Day Telephone: / 7 75 -550% City �1�1'. 654. City State Zip Date Application Expires: / L [ Staff Initials: Page 6of6 RECEIPT NO: R07 -02378 Initials: JEM User ID: 1165 Payee: WESTFIELD SET ID: S000000882 SET TRANSACTIONS: Set Member Amount D07 -407 EL07 -635 M07 -232 PG07 -290 TOTAL: Payment ACCOUNT ITEM LIST: Description ter City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: http:/lwww.dtukwila.wa.us 11,476.92 4,127.50 1,896.75 561.00 18,062.17 TRANSACTION LIST: Type Method Description Check 06008923 BUILDING - NONRES ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE SET RECEIPT TOTAL: Account Code Current Pmts 000/322.100 6,952.98 000.322.101.00.0 3,302.00 000.345.832.00.0 825.50 000/322.100 88.00 000/322.100 1,523.40 000/345.830 4,996.79 000/322.100 369.00 000/386.904 4.50 TOTAL: 18,062.17 Payment Date: 10/31/2007 Total Payment: 18,062.17 SET NAME: 'I'mp set/Initialized Activities Amount 18,062.17 18,062.17 Parcel No.: Address: Suite No: Applicant: Receipt No.: R08 -03578 Initials: BLH User ID: ADMIN Payee: doc: Receiot -06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:Ilwww.ci.tukwila.wa.us 6364200010 2437 SOUTHCENTER MALL TUKW BORDERS BOOKS PATRICK BURNS TRANSACTION LIST: Type Method Descriptio Payment Check 3513 ACCOUNT ITEM LIST: Description Account Code MECHANICAL - NONRES 000/322.100 RECEIPT Amount 58.00 Current Pmts 58.00 Total: $58.00 Permit Number: M07 -232 Status: ISSUED Applied Date: 10/31/2007 Issue Date: 03/17/2008 Payment Amount: $58.00 Payment Date: 10/21/2008 12:58 PM Balance: $0.00 Printed: 10 -21 -2008 Parcel No.: 6364200010 Address: 2437 SOUTHCENTER MALL TUKW Suite No: Applicant: BORDERS BOOKS Receipt No.: R08 -01557 Payee: MERIT MECHANICAL, INC. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 05/12/2008 11:02 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 23724 58.00 Account Code Current Pmts 000/322.100 58.00 Total: $58.00 Permit Number: M07 -232 Status: ISSUED Applied Date: 10/31/2007 Issue Date: 03/17/2008 Payment Amount: $58.00 2269 05/12 9711 TOTAL 58.00 doc: Receipt -06 Printed: 05-12 -2008 COMMENTS: Type of Inspection: /�'r "• r 9/-1 lc trite Special Instructions: Date _ Wanted GG 1 ` Phone No: i Project: 1.) 0 fC(P s , GOkS Type of Inspection: / J Addles 7 7 / g// Date Called: Special Instructions: Date _ Wanted GG �� Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t" " 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 J Approved per applicable codes. 'Date: 7 2 El $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. !Inspector; !Receipt No.: 1Date: Corrections required prior to approval. , "7123Z_ I Project: Orcieirs Type of Inspection: �� . fi - -n r Address: 43 7 rn A l Date Called: Sp Instructions: Date Wanted: -- Z 1— OD p.m. Requester: Phone No: _ ` G7 4 42 4 42 — 61 . 7 y( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: geh,.5i _r f (S D (Inspector: Date: 7 - 21 -0 6 ri $60.00EEINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: rte.. �.�._...... �. 1 ' COMMENTS: Type of Inspection: P1u P C-AAt `kC\< , NA Address: Z'1iC1 %*\C\‘ Date Called: V 1 1 / 4 ,4 'c�i1 I ��A(c ^ 0# V \—' u r•\ ( — k 4- ■ Requester: ` Y-k\(\s `. -t(.)e Phone No: La S 0 t-` �, \ ,} K��/\rec V L \\ ' ? QC\ T I) - \ 0• Z c ,...7\.r Qt � „,_ 1•L\ 3 5\ n-- U - '?, \ � "R--c- J- A .7: -,, „... NI 1\ n't..\\ ''P, er\ Project: r\c t --, Type of Inspection: P1u P C-AAt `kC\< , NA Address: Z'1iC1 %*\C\‘ Date Called: Special Instructions: Date Wanted: 7 . , C' Il a.m. p.m. Requester: Phone No: La S L i L i 7 -- n i S INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. Inspector Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Proje • 7a't°9/S Type In 1799—/Iii Date Called: Address- -7 97/3 / Special Instructions: Date ante / Requester: Phone ... -W :5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER IT CITY OF TUKWILA BUILDING DIVISION K 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. 1Z COMMENTS: rt &L' Dkis e ' , e e sus Q�t Date: 61 f t ae JJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: T Type of Inspection: Address / 37 /00W/ D Date Called: J J Special Instructions: D Date Wanted: �a l a a.m. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1)11)7- 23). PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ; 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 El Approved per applicable codes. L.__! Corrections required prior to approval. COMMENTS: -/ 5/4 cl 4 5•e - v r I ttc, escc jt - o >n_ 1/41/ 2v: See . nti ; 1n 1st # 11/0 Inspector: Date: El $60.00 ` NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at •300 Southcenter Blvd., Suite 100. to schedule reinspection. 'Receipt No.: 'Date: COMMENT / Type of Inspection: 2L /Y /y '' s/4 f� i%fr 7, 5 /A c c� /r► hc ••aaAe 6Ln r/ d ( , - ,' 5 5ers4 ij, _7 f ors'Y) 4apvi AI' - 1 Special Instructions: See p lAA p ) P. if OD p.m. Requester: Phone No: yes yYa-Soly Project: 1 .s /2/(S Type of Inspection: 2L /Y Address: 24 37 /1 Date Called: Special Instructions: Date Wanted: ? 5- 3° " ° k p.m. Requester: Phone No: yes yYa-Soly r /D7 - a3a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El $60.0(*EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Approved per applicable codes. El Corrections required prior to approval. Date:.,, // e . (Receipt No.: `Date: COMMENTS: _ e4. tie :ft Trchk A,..d' 55p,.rG( f g l S oN $ r are, 0- - /i0 V Airs Ad ress: Q l/ L/3 7 '7 AS 1�«14 4 ki 14/01.. S Y H Special Instructions: Date Wanted: /-4 r .. Requester: Ph a No off - X Proje • 1 /P, S ICS Type of nspection: /12_ 4 - i/U Ad ress: Q l/ L/3 7 '7 Date Called. Special Instructions: Date Wanted: /-4 r .. Requester: Ph a No off - X INSPECTION RECORD Retain a copy with permit 016723? INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. 0 Corrections required prior to approval. Inspector: (Date: s _t 3 ^ 'gib SPECT1ON FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: Type o Inspection: 1 Address: 2`f 37 h4(k Date Called: Special Instructions: Date Wanted: io - Of/ �.II p.m. Requester: Phone No: S 1Mo7-2 2_J PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 p INSPECTION NO. ID Approved per applicable codes. El Corrections required prior to approval. COMMENTS: P, . (t) PO)&A- AppreQaCi In w `i IA 1e4 P L f S-e-f re l y ector: Dam__ lan., A. 1 1 � ,, , 4-, - G - v � j EINSPECTION FEE R QUIRED. Pr to inspection, fee must be 6300 Southcenter Blvd., Suite 100. lithe schedule reinspection. J Rece.t o.: 'Date: I INSPECTION RECORD Retain a copy with permit Project: /_ / k5 Type of Inspection -_ / Utter ��SGC/� Address: 22 ll L 'YJ7 sow/41.0i *,- Date Called: Special Instructions: y?-s y/a soy ? Date Wanted: 54 d �— � p.m. Requester: Phone No: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION PERM NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 COMMENTS: Ba7111 rod 04 hard 1, • 4ve46 di k O "er, J ✓GUs1i1 1 04o j o yr ,//l,Y) Approved per applicable codes. Corrections required prior to approval. El $58.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Pro' t: „ ^ $ r ikw "T of pecti e s H 3"I 5. C.. Date Called: Special Instructions: Date Wanted: Z.-* Q a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit I INS'ECTION NO. PERMIT NO. CITY'OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 - 3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: c?A'- 70 1 PA & Ilnspector: * r � • 1.4L9 (Date: 4 -44 C) I $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. !Receipt No.: !Date: INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit /'1 23$? PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: p 10rIlrs /�odrc Address: 214 37 5,,. - 14e,14. fl/' Special Instructions: Type of Inspection: Date Called: Date Wanted: Requester: Phone Phone No: /25' ggo2 5 Corrections required prior to approval. COMMENTS: PTV 1 .1"'ti.1 t- A t t 0 ,1 ecvl"...S 5. t -T 'Inspector: _ j° i 'Date: lit) toe $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Proj 110 P� 1� �' S. '— Type Inspection: V- ` 0 . LI4...& —Q,.. Address: 'D4 c. CM , vkAkk,_ Date Called: Special Instructions: Date Wanted: \?-(0 m. ' Requester: Phone No: I INSPECTION RECORD Retain a copy with permitt" 0 1 - Z3)1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION vie- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: o- o'( PA( A P_ ko tire Approved per applicable codes. Inspector: _ t Corrections required prior to approval. Date: k 7--i ( Q $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: n Project: e f ),', , 453 Sprinklers: Fire Alarm: Type of nspection: 1 E-4 f. ..,-,. ( / Address: : 3, --/ Suite #: ' _c . ' Contatt Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT ndover Park East, Tukwila, Wa. 98188 206-575-4407 proved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS n Corrections required prior to approval. COMMENTS: Inspector: o Date:07/0 Hrs.. ' n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 April 8, 2008 Shay Sabour 12645 NE 140 St Kirkland WA 98034 RE: Request for Extension #2 Development Permit No. D06 -393 Mechanical Permit No. M06 -232 Plumbing/Gas Piping Permit No. PG07 -004 Pacific Court Bldg B — 4028 S 146 St Dear Mr. Sabour, This letter is in response to your written request for an extension to Permit Nos. D06 -393, M06- 232, and PG07 -004. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending the expiration date of your permits an additional 180 days, through October 3, 2008. Please also note that there is a revision which provided footing and deck details that needs to be picked up. There are no fees owing for this revision, but this paperwork must be out in the field for the inspectors prior to final inspection. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. D06 -393, M06 -232, PG07 -004 P:\Pemrit Center\Extension Letters\Pemrits\2006\D06 -393+ Permit Extension #2.doc Page I of I lem fifer Marshall it Technician Cizy of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 L ei, w j S e o v p "or-ly atr 0 / %3 S I v "7"% l- r Cz1en fio.,, Mob -23D.. 1 Mod _ 2.31 P &cc 0°3 � P o 'f � D 0 4- 35 0-/ 39 3 (d; eva pG).J2e, accef hj /11,, (1.,:til f* � ... 'Aar 2- r*K-4..-31 f EzAe--c- cce0 ""4-' ti Net, ci-tIoulfi 5 - r 90 l(v2i n cw-e- 7 1 �� c REOEIVE. R g ?OM com.muN�TY i, & al orki ic) e go ‘44 03 -05 -2008 MICHAEL A CHIODINI 1401 S BRENTWOOD BL ST LOUIS MO 63144 RE: Permit Application No. M07 -232 2437 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 10/31/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 04/28/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/28/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, fifer Marshall Permit Technician xc: Permit File No. M07 -232 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 SUMMARY OF REVISIONS TO HVAC/PLUMBING PLANS SHEET P120 Revised to show all floor sinks and floor drains connected to grease interceptor. Dishwasher drain was moved to sanitary waste line. Additional notes were included for clarification of thermostatic mixing valve use on hand sinks, and backflow preventer use on carbonator machine. General notes have been updated to clarify use of the backflow preventer. Supply and indirect - waste provisions have- been made for the - inclusion - of a carbonator machine. Dimensional plan and equipment schedule have been revised per the addition of the carbonator machine. SHEET P130 Riser diagrams were updated to reflect the changes to sheet P120. SHEET P200 Details for the dishwasher drain line connection have been modified to reflect changes to sheet P120. Trap primer details were modified to reflect routing through the grease interceptor. A thermostatic mixing valve detail for the hand sinks has been added. SHEET H100 Smoke detector added to fan powered VAV -6. VAV -1 through 5 are not fan powered. HVAC for elevator machine room provided by base building. Wm z 3 2 engineering December 18, 2007 CORRFCTIOM LTR #A-._ RECEIVED DEC 2:0 2007 PERMIT CENTEF, December 5, 2007 Michael Chiodini 1401 S Brentwood Bl St Louis MO 63144 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M07 -232 Borders Books — 2437 Southcenter Mall Dear Mr. Chiodini, City of Tuki,vila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson, at 206 431 -3678, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messeneer service. If you have any questions, please contact me at (206) 431 -3670. Sincerely q cwv1-u— Bill Rambo Permit Technician encl xc: File No. M07 -232 P:\Permit Center\Correction Letters \ 2007%407-232 Correction Ltr #I.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 - 366. Building Division Review Memo Date: November 29, 2007 Project Name: Borders Permit #: M07 -232 Plan Review: Dave Larson, Senior. Plans Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The ventilation system for the elevator machine room may need to comply with state amendments to section 3006.2 of the IBC. If the room contains solid state equipment for elevator operation, then makeup air may need to be obtained from outdoors. The system needs to maintain the room temperature between a range specified by the manufacturer or if not specified then between 55 and 90 degrees. See exception for buildings four stories or less that allows natural or mechanical means other than an independent ventilation or air conditioning system to maintain ambient air temperature and humidity in a range specified by the elevator equipment manufacturer. The ventilation system shown appears to exchange air with a short hallway of limited size. Please provide additional information to clarify the need for cooling and how this will be accomplished without additional components to the system. 2. VAV -6 will need to have a return duct mounted smoke detector. It is over 2000cfm and even if RTU- 4 shuts down, VAV -6 will circulate smoke by drawing backflow through the other supply ducts attached to RTU-4. 3. Please confirm that VAV's 1 through 5 are not equipped with their own fans. These VAV's would also need to be interlocked with their associated RTU to shutdown if they are fan powered. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. Documents/routing slip.doc 2 -28-02 ACTIVITY NUMBER: M07 -232 DATE: 07 -18 -08 PROJECT NAME: BORDERS SITE ADDRESS: 2437 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 2 after Permit Issued DEPARTMENTS: BLlilding tivis o�n Public Works ❑ Comments: PLAN REVIEW /ROUTING SLIP APPROVALS R CORRECTIONS: PERMIT COORD COPY Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07-22-08 Complete I V Incomplete ❑ Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route d Structural Review Required REVIEWER'S INITIALS: El n ❑ Permit Coordinator ❑ No further Review Required DATE: DUE DATE: 08-19-08 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Planning Division n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 - 232 DATE: 05 - - PROJECT NAME: BORDERS SITE ADDRESS: 2437 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # I After Permit Issued DEPARTMENTS: 4,0V Bui Di I ibn Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -06 -08 Complete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg El Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions El Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 611 Pt & T Fire Prevention C Structural ❑ Permit Coordinator ❑ Incomplete ❑ Planning Division Not Applicable ❑ DUE DATE: 06 -03 -08 ACTIVITY NUMBER: M07 -232 DATE: 12 -20 -07 PROJECT NAME: BORDERS BOOKS SITE ADDRESS: 2437 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: U‘O05 , BuWdli`ig iD vision Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION 0 COMPLETENESS: (Tues., Thurs.) DUE DATE: 2 -27 -07 Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROJJTING: Please Route Documents/routing slip.doc 2- 28-02 PERMIT COM COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Planning Division Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 0144 -08 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Comments: Documents/routing slip.doc 2 -28-02 TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: , COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -232 DATE: 11 -01 -07 PROJECT NAME: BORDERS BOOKS SITE ADDRESS: "& SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 2 �� -D Building Division F51 ention Public Works ❑ Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1� Incomplete ❑ DUE DATE: 11-06-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DATE: DUE DATE: 12 -04 -07 Approved ❑ Approved with Conditions (n Not Approved (attach comments) F/ Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator n n n Permit Center Use Only CORRECTION LETTER MAILED: L S — G� Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS a- •19,•Dc Summary of Revision: (� U Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS a- •19,•Dc Summary of Revision: (� U Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS a- •19,•Dc Summary of Revision: (� U Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS a- •19,•Dc Summary of Revision: A 4 d, ( l kt, Wmh k- i I); y 1,6, t-v►.- A -( ou^-d (,U - t (� U Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: 1 a 1( - ( r n w evv9S c .4 AA— S (.) c -Qr Received by: OCt-r n z , i( PROJECT NAME: lorkf v's� PddALS PERMIT NO: `" (� - 23 SITE ADDRESS: L 7 s e,„ae,r , bk ORIGINAL ISSUE DATE: 3_ n ) REVISION LOG (please print) (please print) (please print) ease print (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Project Name: r- d G,- l< Entered in Permits Plus on lapplicationslforms- applications on linelrevision submittal Created: 8 -13 -2004 Date: . 7 / /e S ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Z [' Revision # ' after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Sheet Number(s): ft 10.0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fad etc. Plan Check/Permit Number: rn d 7 - 2_3 2_ cn OP rtri tm. 18 2008 Palm cevrai Project Address: .2V 12) 1 Contact Person: / /lCc.Y- .r JaIJJ Phone Number: 8/ - 4 - g`7 2-3 Summary of Revision: e � - — 4 he e e- 7 e -1 Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci. tukwila.wa.us lk Entered in Permits Plus on 1e pplicationslfozms- applications on linekevision submittal Created: 5-13-2004 Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: /ll p7 -- 2_32_ ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: -�� Project Address: X 443 7 e50 e ? ie'�e..i /44 !0 / 7k k[di /� � 41,14- ci t/ � - s Contact Person: P?1mam rEa[7ic ' r Phone Number: a06 — 86 L - Go 7 Summary of Revision: Pe ccr: 5 A) na Left ctti 1 cod e 4. 1 i yr ccr ermile„ Carr-I■pt.i-rvi‘ 7 � cofi 4 55 I L f A L /23 (C 4 dd 1. Sheet Number(s): ID/ 1 pi 249 H. 3o 6 "Cloud" or highlight all area of revision including date of revision Received at the City of Tukwila Permit Center by: C OF rukwu MAY 0 2 2008 PERMIT cE1vrEA Date: 12(itivi Sheet Number(s): /1la0 City of Tukwila \applicationsVbrms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: M07-232 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Borders Books Project Address: 2437 Southcenter Mall Contact Person: Michael Chiodin » y�� Phone Number: Summary of Revision: J1Z L 51/0/ '''"'I' /42 • ':. f "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Er Entered in Permits Plus on — )4) — Q r Steven M. Mullet, Mayor Steve Lancaster, Director ; cD °, t • OF TUKWILA DEC 20 20011 Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V PRESIDENT 02/14/1984 Bond Amount KIRKWOOD, JOAN M SECRETARY 02/27/2006 1 FRICKBERG, WILLIAM MICHAEL VICE PRESIDENT 02/27/2006 Bond Information Bond Bond Company Name Bond Account Number ,\ Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 \Aar' Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License Licensee Name Licensee Type UBI Ind. Ins. Account Id Business Type Address 1 Address 2 City County State Zip Phone Status Specialty 1 Specialty 2 Effective Date Expiration Date Suspend Date Separation Date Parent Company Previous License Next License Associated License MERITMI163CM MERIT MECHANICAL INC CONSTRUCTION CONTRACTOR 600517946 46817500 CORPORATION PO BOX 2109 REDMOND KING WA 980732109 4258839224 ACTIVE GENERAL UNUSED 2/14/1984 6/1/2009 AUTOMMC044QH https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MERITMI163CM 03/17/2008 1 HVAC PLAN 0 H100 SCALE: 1/8" = 1'•0" 2 ELEVATOR MACHINE ROOM HVAC DETAIL 0 H100 SCALE: 118" =1' -O" r ---- rIV1T - -- - 1111 I ------ 1 1 11 1 - - -- -1 11 1 1 1 - - - -- 11111 -- 11 1- -- _11111-- ___.{11 1 1 1 F ------- 1 1 r 111 T "_ - 1 1 1 I I---- -1 - -- --1 1 1 1 1 I1- - - -- 11111 - - - 111 1l_-- __111Il____�1I 11 11111 1 11 - -- 11111 -- -- 111 11 ---- - 1111 -- - - 111 1 1 1 1 I1 - -- 11111--- --111 1 - 1 - -- - 11111 _ - - -J 11 11111 1 1I----- 1111r - ---I 1 1 11 ----- 1111 - - - _ 11 1 1 1 1 - 1 - - - -1I1 - - -- - 111 11 ---- - 11111 - - -- - 111 1 1 1 1 I1 - -- 11111 --111 1L 11111 ��11 - 1 - - -- 11111-- - - -11 IL - -- _11 IL_ _J11 1 1T n I I I -°" :I :Pl_73 Mil : ::PI!®ii 1. 1 1 -- 1 I I L - J .11 UP 11 'I 'I 1 I I r- EXISTING HVAC SYSTEM IN ELEVATOR MACHINE ROOM PROVIDED BY LANDLORD. ,J.5 11 11 it 11 II II II II II 11 II 11 LL (TYP IN SALES AREA) 10 "0 10 "0 10 10 "0 10 "0 10 "0 10 "0 — � 10 "0 10 "0 1 O "0 10 "0 10 "0 10 "0 300 _ 10 "0 10"0 10 "0 10"'0 RTUI.1 411 /18' SA W /11 10 "0 44/18 SA W/ 1 "AL I � I 10 "0 10''0 10"0 1 0 "0 1 0 " 0 10 "0 . _. 10"0 VAV -1 ABOVE 10 "0 10 "0 10 2/12 E - 10 "0 10 "0 SA 10/12 12/12 S 1 12/6 EA 22/10 2q/14 SA 22/10 10/10 A 110 "0 22/22 10 "0 10 "0 10 "0 10 "0 10"0 295 VAV -7 UH -1 PROVIDE BOTTOM OF UNIT AT 12" AFF (TYP OF 2) 10" 110"0, 1.0 "0 10 "0 RTU -4 QN ROOF ABO L 1010 10'0, 10"O RTU -3 10 "0 A ', 10"0 ;1'01'0 10'0 10 " J - - - -� -- 'I 22/6 EA (TYP OF 0) 12/12 SA 10 "0 SA ( A REFRIGERANT PIPING BETWEEN CU -1 ON --` ROOF AND AC -1 IN OFFICE AREA CEILING. INSTALLED BY HVAC CONTRACTOR AND SIZED PER MANUFACTURER'S RECOMMENDATIONS. 12/4 EA A _1 UH -1 960 (PROVIDE FIELD FABRICATED PLENUM FOR FULL - - SIZE OF LINEAR GRILLE, WITH (2) 12 "0 SA ma CONNECTIONS TAPPED INTO PLENUM. BALANCE EACH 12 "0 SUPPLY AIR BRANCH DUCT TO 480 CFM) (GYP T 7 12/12 EA UP TO EF -1I 1- OP IN OFFI 22/10 RA AC -1 ABOVE CEILING. SEE DETAIL ON SHEET H200 FOR DUCT SIZING AND INSTALLATION. CU -1 ON ROOF ABOVE F 2) (TYP OF 2) HVAC SYMBOLS 117-20/12 RECTANGULAR DUCTWORK. SIZE IN INCHES, FIRST NUMBER IS SIDE SHOWN. RETURN, RELIEF OR EXHAUST AIR DUCT. LtEZ 1. . -E=1E %\ SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN SHOWN EQUALS 4 -WAY. OR AS NOTED RETURN AIR GRILLE ROUND DUCTWORK. DIAMETER IN INCHES. SUPPLY OR OUTSIDE AIR DUCT HIGH EFFICIENCY TAP WITH DAMPER AND FLEX DUCT AT DIFFUSER CONNECTION. (SEE BRANCH TAKE -OFF DETAIL ON SHEET H200) DUCTWORK TRANSITION FROM RECTANGULAR TO ROUND. DUCTWORK SIZE TRANSITION. SUPPLY OR OUTSIDE AIR DUCT UP SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN AIR DUCT UP RETURN AIR DUCT DOWN POINT OF CONNECTION - NEW TO EXISTING MANUAL VOL. DAMPER A - TAG B - NECK SIZE C - AIRFLOW (CFM) FIRE DAMPER Pt Mar rovi Approva the violas of approv 90 DEGREE DUCTWORK ELBOW WITH TURNING VANES. B y. Dat MISCELLANEOUS AL DN EA EF EX RA RTU SA TYP W/ REMOTE TEMPERATURE SENSOR THERMOSTAT RETURN DUCT MOUNTED SMOKE DETECTOR DRAWING NOTE REFERENCE ACOUSTICAL LINING DOWN EXHAUST AIR EXHAUST FAN EXISTING RETURN AIR ROOFTOP UNIT SUPPLY AIR TYPICAL WITH e 11 GENERAL NOTES: SCOTT D. MARSHALL NATIONAL ACCOUNT MANAGER EMERSON CLIMATE TECHNOLOGIES - SOLUTIONS 3179 STEINRUCK ROAD ELIZABETHTOWN, PA 17022 PHONE: 717- 930 -0808 FAX: 419- 735 -7605 EMAIL: SCOTT .MARSHALL @EMERSONCLIMATE.COM KEY NOTES: CITY RECEIVED JUL 1V008 ?008 ' PERMIT CENTE FILE C Pl( rmit No. _ 1' Z. Ow approval Is subject to errors and omissions, of construction documents does not authorize on of any adopted code or ordinance. Receipt Field Copy and conditions is acknowtedoed City of Tukwila SU` AING DIVISION 4. ENERGY MANAGEMENT SYSTEM DRAWING TO BE PROVIDED BY EMERSON CLIMATE TECHNOLOGIES. CONTACT EMERSON FOR INFORMATION REGARDING ENERGY MANAGEMENT SYSTEM. REVIEWED FOR CODE COMPLIANCE APPR JUL 2 2 200 City Orru . ± ►13 Mai% WISP 0 0, L ..._.____________ e made' to the c pe N riot app of � ut p ®LVlslon. uil tan submittal t OTE uire a req ►an review fee am ddltlanai p 1. HVAC CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS AND PROVIDE SHOP DRAWINGS AS REQUIRED IN THE SPECIFICATIONS. CONTRACTOR SHALL COORDINATE HVAC DUCTWORK SIZES AND INSTALLATION WITH FIELD CONDITIONS PRIOR TO DUCT FABRICATION. COORDINATE ANY REQUIRED MODIFICATIONS TO DUCTWORK SIZES OR ROUTING WITH ENGINEER PRIOR TO FABRICATION. 2. TEMPERATURE SENSORS ARE TO BE INSTALLED AND WIRED BY THE HVAC CONTRACTOR, MOUNT AT 5' -6" ABOVE FINISHED FLO'IR UNLESS OTHERWISE NOTED. 3. HVAC CONTRACTOR IS RESPONSIBLE FOR LOCATING THERMOSTATS AND TEMPERATURE SENSORS SO AS NOT TO INTERFERE WITH STORE FIXTURES OR OTHER EQUIPMENT (IE. COMPUTERS, COPIERS FAXES, ETC.). ALSO COORDINATE INSTALLATION TO ACCOMMODATE SLAT WALL COLUMN FINISH. SEE SHEET Al23 FOR DETAILS. 5. INSTALL ALL SUPPLY AND RETURN AIR DUCTWORK AS TIGHT TO THE BOTTOM OF STRUCTURE AS POSSIBLE. 6. HVAC CONTRACTOR IS RESPONSIBLE TO NUMBER ALL ROOFTOP UNITS. USE 4" VINYL NUMBERS. 7. HVAC CONTRACTOR MUST REPLACE ALL AIR FILTERS IN ROOFTOP UNITS AND FAN POWERED VAV BOXES WITH NEW CLEAN FILTERS BEFORE AIR BALANCING AND PRIOR TO FINAL TURNOVER TO BORDERS. 8. G.C. SHALL FOLLOW ALL CURRENT CODES AND BE LICENSED WITH CITY OR STATE AS REQUIRED. 9. PERMITS SHALL BE SUBMITTED PRIOR TO ANY WORK BEGINNING. 10. ALL SUPPLY AIR DUCTWORK (INCLUDING INTERNALLY LINED DUCTWORK) SHALL BE EXTERNALLY WRAPPED W/ INSULATION. (SEE SPECIFICATIONS) 11. PROVIDE ADDITIONAL DUCT TRANSITIONS W/ RISES AND DROPS TO AVOID OTHER PIPING, DUCTWORK, CONDUITS, STRUCTURAL MEMBERS, ETC AS REQUIRED. 12. DUCT SIZES REPRESENT SHEET METAL DIMENSIONS. 13. DUCT TRANSITIONS SHALL BE MADE WITH A MAXIMUM 15 ANGLE OF DIVERGENCE. 14. ALL BRANCH DUCT SIZES NOT SHOWN ON PLAN SHALL MATCH DIFFUSER TAG NECK SIZE. JET POINT ADJUST /TEMPERATURE SENSOR AND CO2 SENSOR. INSTALL LOW VOLTAGE CONTROL WIRING FROM SENSOR TO RCOFTOP UNIT. COORDINATE INSTALLATION OF TEMPERATURE SENSOR AND CO2 SENSOR WITH EMERSON ENERGY MANAGEMENT DRAWINGS. TEMPERATURE SENSORS AND 002 SENSORS ARE PROVIDED BY AAON. PROVIDE 32/50 RA OPENING ON TOP OF LINED RA DUCT. DIFFUSERS AND GRILLES IN TOILET ROOM CEILING SHALL BE CENTERED BETWEEN LIGHT FIXTURES. CU -1, FIRE ALARM / SECURITY ROOM CONDENSING UNIT, FURNISHED BY LANDLORD, INSTALLED BY HVAC CONTRACTOR. REFRIGERANT PIPING FURNISHED AND INSTALLED BY HVAC CONTRACTOR. PROVIDE RETURN AIR GRILLE WITH TRANSFER AIR BOOT. SEE DETAIL ON SHEET H200. 10/10 EA UP FROM El. CONNECT INTO BOTTOM OF 12/6 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 22/22 EA UP FROM E2. CONNECT INTO BOTTOM OF 22/6 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 6/22 EA UP FROM E2. CONNECT INTO BOTTOM OF 12/12 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 38/14 LINED RA UP TO RTU RA CONNECTION IN RISE WITH FLEX CONNECTION AT RTU. NOT USED. 44/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU. 38/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU. VAV T'STAT /SENSOR SEE EMERSON CONTROL DRAWINGS FOR WIRING OF VAV CONTROLS TO ENERGY MANAGEMENT SYSTEM. !ZEVISION PROJECT NO. 2007.021 INTERIOR FINISH BORDERS NC, EXPRESSLY RESERVES HS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE "ARCHITECTURAL WORKS" AND `TECHNICAL DOCUMENTS" AND ANY DERM1IVES THEREOF THESE WAWA AND DOCUMENTS ARE NOT 10 BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER USE WITHOUT FIRST CO NINt THE EXPRESS WRITTEN CONSENT OF BORDERS INC., NOR ARE THEY TO BE ASS1OIlER 10 ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT. 0 COPYRIGHT PING EXPIRES 07 -25 -09 ISSUED FOR: PERMIT 81DIIrTAL REVISION 01 MINION *2 REVISION 03 REVISION *4 REVI010N *5 REVISION 0e REVISION *7 8/24/07 x/24/08 4/14/06 4/23/00 5/9/06 5/20/06 0/8/06 0/17/08 REVISION 08 7/10/00 SHEET TITLE HVAC PLAN STORE NO. # 1 6 RELO TENANT IMRROVEI4EN1t SHEET NO. H100 2 ELEVATOR MACHINE ROOM HVAC DETAIL 0 H100 SCALE: 118" =1' -0" 1 HVAC PLAN 0 H100 SCALE: 118" =1' -0" TI m % ----1 1 1 I III lllr -I II -- 1 111 1 . - -- - I I 1 1 I r ---- - 11111 - - - - 111 1 11-------01 III IIIII 1 1 -- -II I1r - -- -111 1 - - - - - I I I I - - - - - 1 I 1 1 1 {I I II ------- 0 1 I r -- --111 1 II■II- - 1 1 1 H I 1 1 1 1 111-----111 11------111 III - - - --I I ■'I ..------All � _ 1 � T 111 11111 11 I l r --- -�1II - -- " __ III -____ 1 - -_--1 1 _ 'Y -------- 1 1 1 1 III Ilr---- 1III1- -- --III I I I--- -- L- - -_ 1 1 1 1 1 1 1 1 I I I OIL -- II11L - -- - 111 11L -� __OWL � J;1 III 1 1 1 I I Ilr - _ 1 IILJ1 ® __ O m 1 1 I 1 .I■ r L_J ® UP A 0 —� — - :] _ r OWP EXISTING HVAC SYSTEM IN ELEVATOR MACHINE ROOM PROVIDED BY LANDLORD. a .15 r -III- LL_ 0 II II II II1 II II II II 11 111 111 III II II II II II 40/16 S� 10 " 44/18, SA W/ 1 "AL 1 0" 0 1 0 "0 3:/14 RA W/ 1 "AL 11 1 0 " ON ROOF ABOVE 10 "0 RTU-3 ON ROO 44/18; 10 "0 10 "0 10'0 -28E} 22/6 EA 10 "0 12/12 E 10 " 8 1 0 2/12 S - -- 10 / 12/12 S 12/6 EA tink 1 10/ 10 "0 10 "0 A - 10 "0 10 ' 'LO" -- 10 " 1 "0 ' 10 "0 10 " 10 "0, 10 " 10 "0 10 "0 10 " A 10"0 32/16 1 0"0 10 "0 1000 10 "0 325 10 "0 10 '0 A 10"0 A' 110" o A 10 "0 A 10 "0 '300 D,. 0 "0 D 10 "0 320 10 "0 11 . 18 SA W/ 1 "AL 10"0 10"0 tr 1 1E '' - I I =I 1 E - 1 1 IL - ill 1L _JI II Ir II II— — I■ 11 1 Il II 11 1 It - -I 1 11 11 N I l 1 1 , I I I I I I 1 I II 11 11 11 1 lj - : I 1 r - 1 1 -1 11 FII I1 11 l l 11 •r 1 1--- 1 1 I II — '11 11 - �! 1 1 11 IL II 11 11 11 II 1 .11 11- -I I .1 1 1 1 i t I 1 I I I - 1 1- 1 1 1 1 ~ -r� - I� " � I I" I 'or II I L Al 1- 1'1 11 I �� -tI'1 - II r I I r I i - - I- I I tl*1 I IL_ _ - -I 1 II 1 II IL - r ‘VP 1L r�'1iP - 11 1,0 " RTU-2 A WO 325 10"0 10 "0 EXISTING HVAC SYSTEM IN VESTIBULE PROVIDED BY LANDLORD. A 10 "0 10 "0 10 "0 10 " 1 0 0 10' 10 "0: 10 "0 ',' 10 "0 10"0 31/14 RA W(1 AL 10 "0 VAV -6 ABOVE 8 SA 38/14 RA W/ 1 "A' 240 - A 10 "0 (TYP OF 3) 12/12 SA SA 10 "0 6 "0 SA'. VAV -2. -VAV 3 1O "0 SA 10"0 325 12/12 EA UP TO EF-1i 140 600 B 8"0 200 (TYP IF 10"0 (TYP IN SALES AREA) 1 370 (TYP OF= 1__ I r 1 YP IN OFFII S- AC -1 8 " 8 "0 AC -1 ABOVE CEILING. SEE DETAIL ON SHEET H200 FOR DUCT SIZING AND INSTALLATION. CU -1 ON ROOF ABOVE 2) (TYP OF 2) HVAC SYMBOLS 120 Jr 4 SUPPLY OR OUTSIDE AIR DUCT UP %■ \% FIRE DAMPER MISCELLANEOUS SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN SHOWN EQUALS 4 -WAY. OR AS NOTED RETURN AIR GRILLE ROUND DUCTWORK. DIAMETER IN INCHES. RECTANGULAR DUCTWORK. SIZE IN INCHES, FIRST NUMBER IS SIDE SHOWN. SUPPLY OR OUTSIDE AIR DUCT RETURN, RELIEF OR EXHAUST AIR DUCT. 90 DEGREE DUCTWORK ELBOW WITH TURNING VANES HIGH EFFICIENCY TAP WITH DAMPER AND FLEX DUCT AT DIFFUSER CONNECTION. (SEE BRANCH TAKE -OFF DETAIL ON SHEET H200) DUCTWORK TRANSITION FROM RECTANGULAR TO ROUND. DUCTWORK SIZE TRANSITION. SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN AIR DUCT UP RETURN AIR DUCT DOWN POINT OF CONNECTION - NEW TO EXISTING MANUAL VOL. DAMPER A - TAG B - NECK SIZE C - AIRFLOW (CFM) • AL DN EA EF EX RA RTU SA TYP W/ REMOTE TEMPERATURE SENSOR THERMOSTAT RETURN DUCT MOUNTED SMOKE DETECTOR DRAWING NOTE REFERENCE ACOUSTICAL LINING DOWN EXHAUST AIR EXHAUST FAN EXISTING RETURN AIR ROOFTOP UNIT SUPPLY AIR TYPICAL WITH Permit Par review appi Approval of c ru the violation'of a of approve Fiek B Date: :sr fi � cca t Lz, Noe ._. 1. HVAC CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS AND PROVIDE SHOP DRAWINGS AS REQUIRED IN THE SPECIFICATIONS. CONTRACTOR SHALL COORDINATE HVAC DUCTWORK SIZES AND INSTALLATION WITH FIELD CONDITIONS PRIOR TO DUCT FABRICATION. COORDINATE ANY REQUIRED MODIFICATIONS TO DUCTWORK SIZES OR ROUTING WITH ENGINEER PRIOR TO FABRICATION. 2. TEMPERATURE SENSORS ARE TO BE INSTALLED AND WIRED BY THE HVAC CONTRACTOR, MOUNT AT 5' -6" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. 3. HVAC CONTRACTOR IS RESPONSIBLE FOR LOCATING THERMOSTATS AND TEMPERATURE SENSORS SO AS NOT TO INTERFERE WITH STORE FIXTURES OR OTHER EQUIPMENT (IE. COMPUTERS, COPIERS FAXES, ETC.). ALSO COORDINATE INSTALLATION TO ACCOMMODATE SLAT WALL COLUMN FINISH. SEE SHEET Al23 FOR DETAILS. 4. ENERGY MANAGEMENT SYSTEM DRAWING TO BE PROVIDED BY EMERSON CLIMATE TECHNOLOGIES. CONTACT EMERSON FOR INFORMATION REGARDING ENERGY MANAGEMENT SYSTEM. 5. INSTALL ALL SUPPLY AND RETURN AIR DUCTWORK AS TIGHT TO THE BOTTOM OF STRUCTURE AS POSSIBLE. 6. HVAC CONTRACTOR IS RESPONSIBLE TO NUMBER ALL ROOFTOP UNITS. USE 4" VINYL NUMBERS. 7. HVAC CONTRACTOR MUST REPLACE ALL AIR FILTERS IN ROOFTOP UNITS AND FAN POWERED VAV BOXES WITH NEW CLEAN FILTERS BEFORE AIR BALANCING AND PRIOR TO FINAL TURNOVER TO BORDERS. 8. G.C. SHALL FOLLOW ALL CURRENT CODES AND BE LICENSED WITH CITY OR STATE AS REQUIRED. 9. PERMITS SHALL BE SUBMITTED PRIOR TO ANY WORK BEGINNING. 10. ALL SUPPLY AIR DUCTWORK (INCLUDING INTERNALLY LINED DUCTWORK) SHALL BE EXTERNALLY WRAPPED W/ INSULATION. (SEE SPECIFICATIONS) 11. PROVIDE ADDITIONAL DUCT TRANSITIONS W/ RISES AND DROPS TO AVOID OTHER PIPING, DUCTWORK, GOND STRUCTURAL MEMBERS, ETC AS REQUIRED. 12. DUCT SIZES REPRESENT SHEET METAL DIMENSIONS. 13. DUCT TRANSITIONS SHALL BE MADE WITH A MAXIMUM 15° ANGLE OF DIVERGENCE. 14. ALL BRANCH DUCT SIZES NOT SHOWN ON PLAN SHALL MATCH DIFFUSER TAG NECK SIZE. 1 SET POINT ADJUST /TEMPERATURE SENSOR AND CO2 SENSOR. INSTALL LOW VOLTAGE CONTROL WIRING FROM SENSOR TO ROOFTOP UNIT. COORDINATE INSTALLATION OF TEMPERATURE SENSOR AND CO2 SENSOR WITH EMERSON ENERGY MANAGEMENT DRAWINGS. TEMPERATURE SENSORS AND CO2 SENSORS ARE PROVIDED BY AAON. GENERAL NOTES: SCOTT D. MARSHALL NATIONAL ACCOUNT MANAGER EMERSON CLIMATE TECHNOLOGIES - SOLUTIONS 3179 STEINRUCK ROAD ELIZABETHTOWN, PA 17022 PHONE: 717- 930 -0808 FAX: 419- 735 -7605 EMAIL: SCOTT .MARSHALL@EMERSONCLIMATE.COM KEY NOTES: PROVIDE 32/50 RA OPENING ON TOP OF LINED RA DUCT. DIFFUSERS AND GRILLES IN TOILET ROOM CEILING SHALL BE CENTERED BETWEEN LIGHT FIXTURES. SEPARATE PERMIT REQUIRED FOR: 0 Mechanical I Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION oval is subject to errors and o11' ttslons. ruction docurn s does not authorize n adopt e i cod or ?rdinance. RecnIpt opy and conditi is etruyt, ?ged: Q, ,,, City of Ta>�+S ftfjja BUILDING DIVISION REVISIONS �� - No changes shall be m�i�10 to th' sronp of work without prior approval of Tukwila Building Division N OTE: Revisions will require a new plan suhrnittal _ and may include additional plan review/ fees (4 ) CU -1, FIRE ALARM / SECURITY ROOM CONDENSING UNIT, FURNISHED BY LANDLORD, INSTALLED BY HVAC CONTRACTOR. REFRIGERANT PIPING FURNISHED AND INSTALLED BY HVAC CONTRACTOR. PROVIDE RETURN AIR GRILLE WITH TRANSFER AIR BOOT. SEE DETAIL ON SHEET H200. 10/10 EA UP FROM E1. CONNECT INTO BOTTOM OF 12/6 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 7 22/22 EA UP FROM E2. CONNECT INTO BOTTOM OF 22/6 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. $ 6/22 EA UP FROM E2. CONNECT INTO BOTTOM OF 12/12 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 38/14 LINED RA UP TO RTU RA CONNECTION IN RISE WITH FLEX CONNECTION AT RTU. 44/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU. 38/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU. VAV T'STAT /SENSOR SEE EMERSON CONTROL DRAWINGS FOR WIRING OF VAV CONTROLS TO ENERGY MANAGEMENT SYSTEM. 12 REVISION N ITS ,REVIEVC/E,) F f CODE COMPLIANCE APPROVED MAY -- 6 2Q08 e +c Of Tukwila BUILD' N DM ION PROJECT NO. 2007.021 INTERIOR FINISH BORDERS INC. D SSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS MD OTHER PROPEIt1Y RIGHTS FOR THESE "ARCHITECTURAL WORKS" AND "'TECHNICAL DOCUMENTS" AND ANY DERIVIiIVES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED. CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE DCPRESS WRITTEN CONSENT OF BORDERS INC.. NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID MITTEN PERMISSION AND CONSENT. COPYRIGHT PENDING 35583 P55 ! 99 _ /may F ISSUED FOR: PERNIT 8IIIIIETTAL REYIBIDN *1 9/24/07 8/24/08 SHEET TITLE HVAC PLAN MAY 1 2008 PERMIT STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. H100 1" INTERNALLY LINED RETURN AIR DUCTWORK RETURN AIR DUCT MOUNTED DUCT DETECTOR PROVIDE RETURN AIR OPENING ON TOP OF RETURN AIR DUCT. SEE PLAN ON SHEET H100 FOR OPENING SIZE. PROVIDE TURNING VANES FOR ALL RECTANGULAR CHANGES OF DIRECTION. END VIEW a ROOFTOP UNIT PROVIDED BY LANDLORD r a100 a a.. a a. a s as a a a a a a a a as a. a a.ae PROVIDE FLEX CONNECTION BELOW ROOF DECK FOR SUPPLY AND RETURN AIR DUCT DROPS. DUCT TRANSITIONS SHALL BE MADE WITH A MAXIMUM 15 ANGLE OF DIVERGENCE. PROVIDE FIRST 15' OF SUPPLY DUCT WITH 1" ACCOUSTICAL LINING. NOTES: 1. CURBS TO BE SET AND LEVELED BY LANDLORD'S SHELL CONTRACTOR. 2. LANDLORD'S SHELL CONTRACTOR TO CUT DECK FOR SUPPLY AIR AND RETURN AIR DUCTS. 3. LANDLORD'S SHELL CONTRACTOR TO INSTALL CURB AND ROOFTOP UNIT. 4. HVAC CONTRACTOR TO INSTALL A FLEXIBLE DUCT CONNECTION BETWEEN RTU AND DUCTWORK. 5. SUPPLY AND RETURN DUCTS ARE TO BE PROVIDED WITH 1" FIBERGLASS "ACOUSTICAL" DUCT LINER BOARD FOR A MINIMUM OF 15' -0" FROM CONNECTION TO ROOF TOP UNIT. 6. DUCT MOUNTED SMOKE DETECTORS ARE FURNISHED BY THE ELECTRICAL CONTRACTOR AND INSTALLED BY HVAC CONTRACTOR IN THE RETURN SECTIONS OF UNIT AS SCHEDULED. SEE SHEET E150 FOR WIRING AND CONNECTION REQUIREMENTS. 7. HVAC CONTRACTOR IS RESPONSIBLE TO NUMBER ALL ROOFTOP UNITS. USE 4" VINYL NUMBERS. *RTU SECTION DETAIL c � SCALE: NONE SCALE: NONE HANGER RODS SUSPEND FROM JOIST. (WITH VIBRATION ISOLATORS) CONTROL SECTION (OTHER SIDE OF UNIT) INLET TO FAN SECTION PROVIDE A MINIMUM OF 4 DIAMETERS OF STRAIGHT DUCT FROM DUCT TAKE-OFF. SUPPLY AIR DUCT (SEE PLANS FOR SIZES) INSULATED DUCT WRAP WITH VAPOR BARRIER AROUND SUPPLY DUCT. FLEXIBLE CONNECTION AT AIR INLET CONNECTION. SUPPORT CHANNEL. FAN POWERED VAV BOX DETAIL SCALE: NONE GAS LINE, UNION, SHUTOFF VALVE & DIRT LEG BY SHELL CONTRACTOR SIDE VIEW DUCT TRANSITIONS SHALL BE MADE WITH A MAXIMUM 15 ANGLE OF DIVERGENCE. PROVIDE FIRST 15' OF SUPPLY DUCT WITH 1" ACCOUSTICAL LINING. Al■Mr■� ---- • ri RTU BY LANDLORD (PROVIDED IN SHELL DESIGN) VENT TRAP was as as A, FLEX CONNECTION GAS PIPING ON ROOF TO ROOFTOP UNIT BY THE SHELL CONTRACTOR CONDENSATE DRAIN LINE (COPPER) TO NEAREST ROOF DRAIN BY SHELL CONTRACTOR ELECTRIC HEATING COIL. PROVIDE DUCT HANGERS WITHIN 12" OF OUTLET. SUPPLY AIR DUCT (SEE PLANS FOR SIZES) PROVIDE 3' -0" MIN. OF STRAIGHT DUCT FROM UNIT 15 MAXIMUM ANGLE (SUPPLY AND RETURN DUCT DROPS) \ROOF SPRING TYPE VIBRATION ISOLATOR (TYPICAL) — FLEX CONNECTION (TYPICAL) AC-1/CU-1 DETAIL SCALE: NONE VOLUME DAMPER SUPPLY AIR DIFFUSER SCALE: NONE TRAPPED CONDENSATE DRAIN AUTOMATIC LEVEL SWITCH TO ACTUATE CEILING MOUNTED INDICATOR LIGHT UPON RISING WATER LEVEL IN SECONDARY DRAIN PLAN. X" THREADED ROD (TYP) AC -1 H3 HARD CEILING CLIP. SLIDE CLIP INTO DIFFUSER GROOVE. PROVIDE CLIPS WITH A MAXIMUM 10" SPACING ALONG DIFFUSER. SECURE CLIP TO CHANNEL. PROVIDE A 10" MAXIMUM 10" SPACING BETWEEN CLIPS. VAX. OF 12" TO BRANCH CO N ECTION 1 -1/2" THICK FIBERGLASS INSULATION W /FOIL FACING GALVANIZED SHEET METAL DUCT CU -1 AIR COOLED CONDENSING UNIT INDICATOR LIGHT FLEXIBLE DUCT MOUNTING DETAIL PATE ES -5 EQUIPMENT SUPPORT RAILS - FURNISHED BY HVAC CONTRACTOR, INSTALLED BY LANDLORD'S ROOFING CONTRACTOR PATE PCA -5 PIPE CURB WITH PCC -5 COVER - FURNISHED BY HVAC CONTRACTOR, INSTALLED BY LANDLORD'S ROOFING CONTRACTOR BALL VALVE N.C. TITUS FL30 DIFFUSER WITH TYPE 11 BORDER 1" T.A. FILTER 1X" x 14" ANGLE (TYP) 1" CONDENSATE DRAIN TO NEAREST MOP SINK CEILING CODE REQUIRED DRAIN PAN SHALL BE 1X" DEEP AND 3" LARGER THAN UNIT ON ALL SIDES NOTE: AC -1 SHALL NOT BE MOUNTED DIRECTLY OVER FIRE ALARM /SECURITY ROOM - SEE PLAN FOR LOCATION GALVANIZED ELBOW METAL STRAP CLAMP (TYPICAL) 2 PLACES PLENUM CLIP INSULATED FLEXIBLE CONNECTION (MAX. 5 FT.) IN VERTICAL ONLY TITUS FBP PLENUM. PRESS PLENUM AGAINST DIFFUSER UNTIL PLENUM CLIPS SNAPS INTO DIFFUSER GROOVE. C4 ENLARGED FLOWBAR DIFFUSER CONNECTION DETAIL } SCALE: NONE 14" HIGH PREFABRICATED, INSULATED ROOF CURB. CURB FURNISHED BY HVAC CONTRACTOR INSTALLATION OF CURB IN COMPLIANCE WITH ROOF MANUFACTURER'S REQUIREMENTS ROOF INSULATION METAL DECK BLOCKING AND LEVELING BY GENERAL CONTRACTOR B5 ROOF MOUNTED EXHAUST FAN DETAIL MINIMUM TAKE OFF AREA 1.25 TIMES BRANCH DUCT AREA A5 TRIM CHANNEL FOR PLENUM INLET AS REQUIRED. FLOWBAR DIFFUSER DETAIL - ISOMETRIC VIEW SCALE: NONE FLOWBAR DIFFUSER DETAIL - SIDE VIEW SCALE: NONE SCALE: NONE GYP BOARD (TYPICAL) RECTANGULAR TO ROUND "BUCKLEY FITTING" 90 COMBINATION TEE WITH OVAL TO ROUND TAP (IF BRANCH FLOW IS 2/3 OF THRU FLOW) DUCT BRANCH TAKE -OFF DETAIL SCALE: NONE SEE ENLARGED FLOWBAR DIFFUSER CONNECTION DETAIL ON THIS SHEET. NOTE: SEE ARCHITECTURAL DRAWING A420 FOR ADDITIONAL INFORMATION REGARDING SIDEWALL OPENING IN SOFFIT. VARIES 2" MINIMUM COLLAR METAL STUD AND CHANNEL. FASTEN H3 CLIP TO STUD /CHANNEL WITH A MAXIMUM SPACING OF 10" BETWEEN CLIPS. METAL STUD AND CHANNEL. FASTEN H3 CLIP TO STUD /CHANNEL WITH A MAXIMUM SPACING OF 10" BETWEEN CLIPS. SINGLE SLOT 3" FLOW BAR JET THROW DIFFUSER. USE BORDER 11 WITH H3 HARD CEILING CLIPS AND ECX END CAPS. H3 HARD CEILING CLIP SUPPLIED WITH DIFFUSER. INSERT CLIP INTO DIFFUSER GROOVE. SECURE CLIP TO STUD WITH A MAXIMUM SPACING OF 10 ". EXHAUST DUCTWORK BY HVAC CONTRACTOR GALVANIZED ELBOW METAL STRAP CLAMP (TYPICAL) 2 PLACES 45 LATERAL FITTING METAL STUD AND CHANNEL. FASTEN H3 CLIP TO STUD /CHANNEL WITH A MAXIMUM SPACING OF 10" BETWEEN CLIPS. ROOF MOUNTED EXHAUST FAN OPENING BY GENERAL CONTRACTOR COORDINATE FRAMING AND OPENING SIZE WITH HVAC CONTRACTOR RECTANGULAR TO RECTANGULAR 2' -34" RUN ROOFING MATERIAL UP UNDER CURB CAP 1 -1/2" THICK FIBERGLASS INSULATION W /FOIL FACING ROOFING WORK BY LANDLORD'S ROOFING CONTINUOUS INSIDE FLANGE CONTRACTOR AT GENERAL FOR MOUNTING OF SURFACE CONTRACTORS EXPENSE MOUNTED REGISTER BRANCH DUCT HEIGHT DIMENSION 2" LESS THAN MAIN DUCT HEIGHT DIMENSION B SCALE: NONE SHEET METAL ELBOW ACOUSTICAL DUCT LINER RETURN AIR GRILLE, AS SHOWN ON PLAN GALVANIZED SHEET SCALE: NONE FLOWBAR DIFFUSER PLENUM. SLIDE PLENUM INTO OPENING SO THAT CLIPS SNAPS INTO DIFFUSER GROOVE. VOLUME METAL DUCT DAMPER INSULATED FLEXIBLE CONNECTION (MAX. 5 FT.) IN VERTICAL ONLY FLOWBAR DIFFUSER PLENUM. SLIDE PLENUM INTO OPENING SO THAT CLIPS SNAPS INTO DIFFUSER GROOVE. METAL STUD AND CHANNEL. FASTEN H3 CLIP TO STUD /CHANNEL WITH A MAXIMUM SPACING OF 10" BETWEEN CLIPS. SINGLE SLOT 3" FLOW BAR JET THROW DIFFUSER. USE BORDER 11 WITH H3 HARD CEILING CLIPS AND ECX END CAPS. MAX. OF 12" TO BRANCH CONNECTION RETURN BOOT DETAIL DUCT REGISTER DETAIL CODE COMPLIANCE 1 A PROVED 0 _ g 200 r ., f - rialoila *00 oristm SCALE: NONE DUCT REGISTER DETAIL miuimuuiuumiiui 18" MIN. vvvvvVVVHV \ +ti +VVVVVti' 10/22 TRANSFER AIR TTT7177T tT!!!!i T?!liit!i DUCT WIDTH SAME AS GRILLE WIDTH, SIZE HEIGHT FOR A MAXIMUM OF 300 FPM OUTSIDE DIMENSIONS OF REGISTER FRAME. SEE PLAN FOR DUCT SIZE AND SCHEDULE FOR FRAME SIZE. 1 LAY -IN CEILING AIR OUTLET PROJECT NO. 2007.021 INTERIOR FINISH BORDERS NC. EXPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR REM "ARCHITECTURAL WORKS" AND "TECHNICAL DOCUMENTS" AND ANY DERR/IMES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED. CHANGED OR COPED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTANING THE EXPRESS WRITTEN CONSENT OF BORDERS INC.. NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTANHNG SND WRITTEN PERMISSION AND CONSENT. Q COPYRIGHT PENDING ISSUED FOR: r >ITTAI. (REVISION *1 SHEET TITLE MECHANICAL DETAILS MAY --1 2008 =(: nAI.1- CF..N1 �: • V/24/O7 3/24/08 STORE NO. #126 RELO TENANT II PROVEMENT SHEET NO. H2O0 ROOFTOP UNIT SCHEDULE ALL RTU'S FURNISHED AND INSTALLED BY LANDLORD MARK SERVICE MANUFACTURER MODEL NOMINAL TONS FAN DATA COOLING DATA HEATING DATA MISCELLANEOUS DATA S.A. CFM E.S.P. IN W.C. HP E.A.T. DB /WB SENS. MBH TOTAL MBH FUEL TYPE INPUT MBH OUTPUT MBH HTG. STEPS POWER V-0-HZ UNIT MCA MIN. O.A. S.A. CONN SIZE R.A. CONN SIZE WEIGHT LBS. REMARKS RTU -1 SALES AREA AAON RM 15.0 5975 0.5 5.0 77.0/62.5 162.6 185.0 NAT. GAS 180 146 2 460-60-3 40 1400 38/22 38/18 1650 A -F RTU -2 SALES AREA AAON RM 15.0 6000 0.5 5.0 77.0/62.5 162.6 185.0 NAT. GAS 180 146 2 460 -60 -3 40 1400 38/22 38/18 1650 A -F RTU -3 SALES AREA AAON RM 15.0 5965 0.5 5,0 77.0/62.5 162.6 185.0 NAT. GAS 180 146 2 460 -60 -3 40 1400 38/22 38/18 1650 A -F RTU -4 SALES AREA AAON RM 20.0 8005 1.25 7.5 77.0/62.5 203.0 230.0 A NAT. GAS 270 219 2 460 -60 -3 53 1125 38/22 38/18 3058 A -H GRILLE REGISTER AND DIFFUSER SCHEDULE HVAC ICONTTRACTTORNSTALLED BY TAG SERVICE MAKE MODEL FRAME /BORDER FASTENING TYPE MODULE SIZE NOTES/ ACCESS. A CEILING SA TITUS OMNI TYPE 3 - LAY IN - 24" x 24" A,B,I B CEILING SA TITUS OMNI TYPE 3 - LAY IN - 12" x 12" A,B,G,I C SIDEWALL SA TITUS 300RS TYPE 1 - SURFACE TYPE A NECK SIZE + 1X" SEE PLAN A C /\ ' 2 \ D SIDEWALL SA TITUS CT541 BORDER 13 TYPE A NECK SIZE + 1%" SEE PLAN 277/10 A,I,J El CEILING EA TITUS 35ORL TYPE 1 SURFACE TYPE A NECK SIZE + 1X /a" SEE PLAN A,C,I E2 CEILING EA TITUS 35ORL TYPE 3 - LAY IN - NECK SIZE + 2' SEE PLAN A,C,I RG CEILING RA TITUS 50F TYPE 3 - LAY IN - NECK SIZE + 2 SEE PLAN A D I > > VAV BOX SCHEDULE ROOM PURPOSE FLOOR AREA (SQ. FT) MARK SERVICE MANUFACTURER MODEL PRIMARY AIR ELECTRIC HEAT 20,205 INLET SIZE MAX AIR (CFM) MIN AIR (CFM) MAX PD ( "WG) EATING (AIRFLOW OUTPUT (KW) VOLTAGE REMARKS VAV -1 SORT ROOM TITUS DESV 10 "0 1140 290 0.35 290 3.0 277/10 1,2 VAV -2 MORS AND CASH OFFICE TITUS DESV 6 '0 340 100 0.25 ' 100 2.0 277/10 1,2 VAV -3 OPEN OFFICES TITUS DESV 8 "0 690 185 0.30 185 2.0 277/10 1,2 VAV -4 TOILET ROOMS TITUS DESV 8"0 550 185 0.25 185 2.0 277/10 1,2 VAV -5 PANTRY TITUS DESV 10"0 1110 290 0.35 290 3.0 277/10 1,2 OUTSIDE AIR REQUIREMENTS ROOM PURPOSE FLOOR AREA (SQ. FT) ASHRAE OUTSIDE AIR REQUIREMENTS SYSTEM NUMBER OUTSIDE AIR (CFM PER UNIT) CFM PER SQ. FT REQUIRED CFM SALES AREA 20,205 .20 4,041 RTU -1 1,400 RTU -2 1,400 RTU -3 1,400 CAFE SEATING AREA 1,436 .20 288 RTU -4 960 CAFE PANTRY 414 0.20 83 STOCKROOM 1,240 0.15 186 OFFICES 934 20 CFM PER PERSON 200 TOILET ROOMS 400 50 CFM PER PERSON 200 TOTAL = 4,798 TOTAL = 4,940 FAN POWERED VAV BOX SCHEDULE MARK SERVICE MANUFACTURER MODEL PRIMARY AIR FAN SECTION ELECTRIC HEAT INLET SIZE MAX AIR (CFM) MIN AIR (CFM) MAX PD ("WO) AIR FLOW CFM PD (WG) HP VOLTAGE OUTPUT (Kw) VOLTAGE REMARKS VAV -6 CAFE SEATING TITUS DTFS -E 14"0 2255 565 0.40 1690 0.50 3/4 277/10 8.0 480V/30 1,2 VAV -7 ENTRANCE TOWER TITUS DTFS -E 14 "0 1920 565 0.60 1355 0.50 3/4 277/10 9.0 480V/30 1,2 EXHAUST FAN SCHEDULE FURNISHED AND INSTALLED BY HVAC CONTRACTOR TAG AREA SERVED LOCATION MAKE MODEL DRIVE TYPE CFM ESP SONE RATING MOTOR H.P. ELECT. VOLT /PH NOTES/ ACCESS. EF -1 REST ROOMS ROOF GREENHECK 0B -091 -4 ADJUST. V -BELT 575 0.50" 7.3 1/4 115V /10 A THRU E EF -2 CAFE PANTRY ROOF GREENHECK GB -091 -4 ADJUST. V- BELT / L 800 \ 0 25" 8.8 1/4 115V/10 A THRU E FAN -COIL UNIT SCHEDULE FURNISHED BY LANDLORD; INSTALLED BY HVAC CONTRACTOR TAG LOCATION MAKE MODEL CFM ESP FAN HP VOLT/ PHASE COOLING CAPACITY NOTES/ ACCESS. TOTAL MBH ROWS REF AC -1 FIRE ALARM / SECURITY ROOM LENNOX CB30M21/26 600 0.30" 1/5 208V/10 18.7 3 R -22 A,B,C,D AIR COOLED CONDENSING UNIT SCHEDULE IURNASHED BY HVAC CONTRACTOR TAG UNIT SERVED LOCATION MAKE MODEL NOMINAL COOLING CAPACITY ELECTRICAL DATA NOTES/ ACCESS. CU -1 AC -1 ROOF LENNOX 13ACD -018 1.5 TONS 208V/10 A THRU I ELECTRIC FAN FORCE WALL HEATER SCHEDULE FURNISHEDOANDAINSTALLED TAG AREA SERVED TYPE MAKE & MODEL ELECTRICAL DATA NOTES/ ACCESS. KW VOLTS UH -1 VESTIBULE WALL QMARK AWH4507 4.8 277 A,B WEATHER DATA CITY NAME TUKWILA LOCATION WASHINGTON LATITUDE 47.0° LONGITUDE 122.0° ELEVATION 386.0 FEET SUMMER DESIGN DRY -BULB TEMPERATURE 80.0 °F SUMMER DESIGN WET -BULB TEMPERATURE 64.0 °F WINTER DESIGN DRY -BULB TEMPERATURE 26.0 °F ATMOSPHERIC CLEARNESS NUMBER 0.95 AVERAGE GROUND REFLECTANCE 0.20 REMARKS A - 14" PREFABRICATED ROOF CURB B - FACTORY INSTALLED DISCONNECT AND 115V CONVENIENCE OUTLET C - POWERED EXHAUST D - PROVIDE WITH 410A OR RFC 134A REFRIGERANT E - UNIT CAPACITIES SHALL BE BASED ON A.R.I. CONDITIONS F - CONTROLS BY EMERSON, PROVIDE WITH TERMINAL STRIP TIE -IN G - FACTORY INSTALLED VFD (SLIPPY FAN) FOR VAV RTU H - HOT GAS BYPASS REMARKS 1. UNITS SHALL BE FURNISHED WITH ALL STANDARD FEATURES AND THE FOLLOWING ACCESSORIES; 1/2" FOIL FACED INSULATION, FACTORY MOUNTED 277/24 VOLT TRANSFORMER W/ FUSING ON PRIMARY, AND 24 VOLT ELECTRONIC DAMPER ACTUATOR WIRED TI A R IA T. ONTROLLER TO BE FURNISHED AND INSTALLED BY AUTOMATIC TEMPERATURE CONTROL CONTRACTOR. . TWO STAGE ELECTRIC HEAT REMARKS 1. UNITS SHALL BE FURNISHED WITH ALL STANDARD FEATURES AND THE FOLLOWING ACCESSORIES; 1/2" FOIL FACED INSULATION, ECM MOTER, FAN CONTROL BOX FUSE, 24 VOLT MAGNETIC CONTROL, AIR FLOW SWITCH, INTERLOCKING DOOR DISCONNECT SWITCH, LINE FUSE, SERIES FAN OPERATION, AND 24 OLT EL TRIk C DAMPER ACTUATOR. CONTROLLER TO BE AS REQUIRED BY THE AUTOMATIC TEMPERATURE CONTROL SYSTEM. J - . TWO STAGE ELECTRIC HEAT NOTE : CONTACT BILLY KODOSKY, FOR AAON PRICING (330)463 -0100 X125. NOTE /ACCESSORY DESIGNATION NO SUBSTITUTIONS ACCEPTED DIRECTIONAL BLOW CLIPS (DB) AS REQUIRED BY DIRECTIONAL ARROWS ON PLAN OPPOSED BLADE DAMPERS CODE A X" x X" x X" ALUMINUM GRID NOT USED NOT USED RAPID MOUNT FRAME NOT USED PROVIDE WITH FACTORY PRIMED FINISH. CONTRACTOR TO PROVIDE FINAL PAINTED FINISH TO MATCH CEILING COLOR. COORDINATE COLOR WITH ARCHITECT. 15° DEFLECTION NOTE /ACCESSORY DESIGNATION A - SAFETY DISCONNECT SWITCH - NEMA 1 - MOUNTED & WIRED B - GRAVITY OPERATED BACK DRAFT DAMPER C - AMCA SEAL & U.L. LISTED D - 14" PRE MANUFACTURED ROOF CURB WITH DAMPER TRAY E - ALUMINUM RUB RING n n NOTE /ACCESSORY DESIGNATION NOTE /ACCESSORY DESIGNATION A - COMBINATION HEAT /COOL THERMOSTAT WITH SUB -BASE B - THROW AWAY FILTER C - INSULATED CABINET D - UNIT WEIGHT = 136 lb A - UNIT CAPACITIES SHALL BE BASED ON A.R.I. CONDITIONS B - HIGH AND LOW PRESSURE SWITCHES ON REFRIGERANT SYSTEM C - THERMOSTAT CONTROLLED CRANKCASE HEATER D - FILTER -DRYER ON COMPRESSOR REFRIGERANT SYSTEM E - CAPACITY CONTROL NOTE /ACCESSORY DESIGNATION: A - BUILT -IN THERMOSTAT B - 4" DEPTH n F - 0 DEGREE LOW AMBIENT CONTROL G - PATE MODEL ES 8" (MIN.) PREFABRICATED SUPPORT RAILS H - U.L. LISTED I - UNIT WEIGHT = 122 lbs. CODE COMPLIANCE APPROVED MAY 6 2008 City Of Tuloilla BUILDING DIVISION PROJECT NO. 2007.021 NTERIOR FINISH BORDERS INC. EXPRESSLY EVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE 'ARCHITECTURAL WORKS' AND 'TECHNICAL DOCUMENTS" AND ANY DERIVITIVES THEREOF. THESE DRAWNGS AND DOCUMENTS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE EWRESS WRITTEN CONSENT OF BORDERS INC., NCR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT. COPYRIGHT PENDING ISSUED FOR: PEWIT SUBMITTAL REVISION 111 REVISION 12 REVISION is 9/24/07 3/24/08 4/14/08 4/23/08 SHEET TITLE MECHANICAL SCHEDULES MAY 12000 STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. H300 STUB 10/10 TA DUCT INTO — ELEVATOR MACHINE ROOM STUB 10/10 EA DUCT INTO -- ELEVATOR MACHINE ROOM 11 1 1 / I 1 ELEVATOR MACHINE ROOM HVAC PLAN SCALE: 1/8"=1 L J }'A_9AA!9!1 "�°"- , 11111- - - - -i11 1 11111 1 r ____1111 111 1---- -1 - - -1 : 11 E ---- 1 11 : 11 E ---- 1 1111 1 1 - - - -- 1 - -_1I1 Ill 1 1 1 11 - - -- 1111r - -- - 11 1 III - - -- -1 -1 1 Ilrll 111 1 1 1 - - -- 1 111 1 -- -- 111 - - - -- 1111 - --a I I I 111l1 111 I l r ---- 1 111 1 - - - I ____I III 1 Ill I 1 r - - - -- 111 - -- -11 I J III 11111 III r- 1 1 1 ---- 1 1 1 1 r ----- iii I JA -- -J Ill !MI III III- - - - -1I 1r- - - - -i11 'IL_ J'�1L- J;1 I W' I w' ill I __ J --- O -MM E momI1 ur - lir 11 U P S I i I � 1 L_J 1 1 I- I _ - J t A 1 1 r 11 — 1 1 1I UP I 1 11 / ` I1 11 � n -- LH- II II II II H II II II II II II II II II u II II II II II II II III, 10 "f A 110°0 10' 111110 1 ° i(:II 11'1ili1T•IT "I' 10 "0 sf�e(d A 110 "0 10" 0 22/22 A t? i ' : - Ji ' RTU -1 0 ROOF A * \ ' 0 1 11.` ''''' �� i4 4 • , 10 0 e 7 INOLNfrOg. i r - 1 , ! ■ AllP4MnA F MEI '' : 4 0 1#7#1 . " WI M 6 A ' , a "7 /, „ _ 0 °0 , r, ' I co ill \ 11 1 k A / r lir- --- A gAl 41 1 ■ . '(/ q r 1 i ,. I _.. - 1 , r , ,-. ,, ,. il 10 • III ' i h 1- $ . 'PIPIT__ 4 100 ^/ . - ® RT IN ROOF .BO.E E h l ■ i a [ VAV -1 12/12 SA 10 "0 12/12 SA ff1f; lPllll llllllll'll'll l� 10 /10 A 10 "0 295 (TYP IN SALES AREA) I n 0 T I TIE S �i A 10' hJ rli `► 11 L. - 10" 1 A �n _ 1 i I 'i.-_;=i.-z -1 - 7 - . I A iiQ'. L 280 — 1 0 "0 Pi I - . (!)--- - RTU- (6-11-- ' 1! -r ... FF H D _ .. z V We il- " AmV .I A 10 0 295 —A , i M Ng ititi HVAC PLAN SCALE: 118".1'-0" ■■ ■■ l 4 �* , 1111 • ono III - 10 ' 0 ,__ 'V •• 1 111 _ — PEI 111=111111111N MN I A 1p'PI Mei 10 „0 r A 10 '21 I A 10 \ � 325 325 ` Nor ::_,I'-._____ i ..._._ r _- 0 °0 J ' F O "0 .: r L 10 "0 A 10'21 A in 3•, 325 4 *irIN 'r )1: 321 ii. , — _ r. ...... .. , F r- - 10 "0 i: :::. 10 "0 1. 1 O ,RTU=3 10 "0 370 (TYP OF lllll 8 Date: HVAC SYMBOLS 120 ROUND DUCTWORK. DIAMETER IN INCHES. 20/12 RECTANGULAR DUCTWORK. SIZE IN INCHES, FIRST NUMBER IS SIDE SHOWN. HIGH EFFICIENCY TAP WITH DAMPER AND J r FLEX DUCT AT DIFFUSER CONNECTION. (SEE BRANCH TAKE -OFF DETAIL ON SHEET H200) DUCTWORK TRANSITION FROM RECTANGULAR TO ROUND. DUCTWORK SIZE TRANSITION, SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN SHOWN EQUALS 4 -WAY. OR AS NOTED RETURN AIR GRILLE SUPPLY OR OUTSIDE AIR DUCT RETURN, RELIEF OR EXHAUST AIR DUCT. 90 DEGREE DUCTWORK ELBOW WITH TURNING VANES. SUPPLY OR OUTSIDE AIR DUCT UP SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN AIR DUCT UP RETURN AIR DUCT DOWN POINT OF CONNECTION - NEW TO EXISTING MANUAL VOL. DAMPER A - TAG B - NECK SIZE C - AIRFLOW (CFM) FIRE DAMPER p�r a oro al TUki ° /1k1 : Ilevisions will require ri r1' w plan l ai. tit'f dit l may y inClud e additional plan review lees. FILE COPY Y N . Plan review swami Is sifted to wore ruld 1 Approval of porstruction dommta does nut authorlz 12/12 EA UP TO EF -1I _J AC -1 8'0 City of Tukwila BUILDING DIVISION A H 8 SEPARATE PERMIT REQUIRED FOR: Ely echanical Dr Electrical - /Plumbing �i Gas Piping City of Tukwila 1 ICI ;II i "liP,i; =� DIVISION 1 - 170 — AC -1 ABOVE CEILING. SEE DETAIL ON SHEET H200 FOR DUCT SIZING AND INSTALLATION. 600 CU -1 ON ROOF ABOVE (TYP 2) MISCELLANEOUS S D AL DN EA EF EX RA RTU SA TYP W/ GENERAL NOTES: REMOTE TEMPERATURE SENSOR THERMOSTAT RETURN DUCT MOUNTED SMOKE DETECTOR DRAWING NOTE REFERENCE ACOUSTICAL LINING DOWN EXHAUST AIR EXHAUST FAN EXISTING RETURN AIR ROOFTOP UNIT SUPPLY AIR TYPICAL WITH IOW coct. CODE COKOPACE. APIPTLO 1. HVAC CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS AND PROVIDE SHOP DRAWINGS AS REQUIRED IN THE SPECIFICATIONS. CONTRACTOR SHALL COORDINATE HVAC DUCTWORK SIZES AND INSTALLATION WITH FIELD CONDITIONS PRIOR TO DUCT COORDINATE ANY REQUIRED MODIFICATIONS TO DUCTWORK SIZES OR ROUTING WITH ENGINEER PRIOR. TO FABRICATION. 2. TEMPERATURE SOSORS ARE TO BE INSTALLED AND WIRED BY THE HVAC CONTRACTOR, MOUNT AT 5' -6° ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. 3, HVAC CONTRACTOR IS RESPONSIBLE FOR LOCATING THERMOSTATS AND TEMPERATURE SENSORS SO AS NOT TO INTERFERE WITH STORE FI OR OTHER EQUIPMENT (IE. COMPUTERS, COPIERS FAXES, ETC.). ALSO COORDINATE INSTALLATION TO ACCOMMODATE SLAT WALL COLUMN FINISH. SEE SHEET Al23 FOR DETAILS. 4. ENERGY MANAGEMENT SYSTEM DRAWING TO BE PROVIDED BY EMERSON CLIMATE TECHNOLOGIES. CONTACT EMERSON FOR INFORMATION REGARDING ENERGY MANAGEMENT SYSTEM. SCOTT D. MARSHALL NATIONAL ACCOUNT MANAGER EMERSON CLIMATE TECHNOLOGIES - SOLUTIONS 3179 STEINRUCK ROAD ELIZABETHTOWN, PA 17022 PHONE: 717- 930 -0808 FAX: 419-735-7605 EMAIL: SCOTT .MARSHALL @EMERSONCLIMATE.COM 5. INSTALL ALL SUPPLY AND RETURN AIR DUCTWORK AS TIGHT TO THE BOTTOM OF STRUCTURE AS POSSIBLE. 6. HVAC CONTRACTOR IS RESPONSIBLE TO NUMBER ALL ROOFTOP UNITS. USE 4 "° VINYL NUMBERS. 7. HVAC CONTRACTOR MUST REPLACE ALL AIR FILTERS IN ROOFTOP UNITS AND FAN POWERED VAV BOXES WITH NEW CLEAN FILTERS BEFORE AIR BALANCING AND PRIOR TO FINAL TURNOVER TO BORDERS. 8. G.C. SHALL FOLLOW ALL CURRENT CODES AND BE LICENSED WITH CITY OR STATE AS REQUIRED. 9. PERMITS SHALL BE SUBMITTED PRIOR TO ANY WORK BEGINNING. 10. ALL SUPPLY AIR DUCTWORK (INCLUDING INTERNALLY LINED DUCTWORK) SHALL BE EXTERNALLY WRAPPED W/ INSULATION. (SEE SPECIFICATIONS) 11. PROVIDE ADDITIONAL DUCT TRANSITIONS W/ RISES AND DROPS TO AVOID OTHER PIPING, DUCTWORK, CONDUITS, STRUCTURAL MEMBERS, ETC AS REQUIRED. 12. DUCT SIZES REPRESENT SHEET METAL DIMENSIONS. 13. DUCT TRANSITIONS SHALL BE MADE WITH A MAXIMUM 15 ANGLE OF DIVERGENCE, 14. ALL BRANCH DUCT SIZES NOT SHOWN ON PLAN SHALL MATCH DIFFUSER TAG NECK SIZE, KEY NOTES SET POINT MUST/TEMPERATURE SENSOR AND CO2 SENSOR, 00 PROVIDE 32/;x0 RA OPENING ON TOP OF LINED RA DUCT. DIFFUSERS AND GRILLES IN TOILET ROOM CEILING SHALL BE CENTERED BETWEEN LIGHT FIXTURES. CU -1, FIRE ALARM / SECURITY ROOM CONDENSING UNIT, FURNISHED BY LANDLORD, INSTALLED BY HVAC CONTRACTOR. REFRIGERANT PIPING FURNISHED AND INSTALLED BY HVAC CONTRACTOR. OD PROVIDE RETURN AIR GRILLE WITH TRANSFER AIR BOOT. SEE DETAIL ON SHEET H200. L=./ 10/10 EA UP FROM El. CONNECT INTO BOTTOM OF 12/6 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 22/22 EA UP FROM E2, CONNECT INTO BOTTOM OF 22/6 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 00 6/22 EA UP FROM E2. CONNECT INTO BOTTOM OF 12/12 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 00 38/14 LINED RA UP TO RTU RA CONNECTION IN RISE WITH FLEX CONNECTION AT RTU. 10 46/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU, 11 44/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU. 12 38/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU. 13 VAV THERMOSTAT. SEE EMERSON CONTROL DRAWINGS FOR WIRING OF VAV CONTROLS TO ENERGY MANAGEMENT SYSTEM. Mop - 13z CORPEC IOi RECEIVED DEC 2 2007 PERMIT CENTEh PR 2007.021 INTERIOR FINISH BORDERS INC. EXPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE "ARCHITECTURAL WORKS" AND "'TECHNICAL DOC MDITS" AND ANY DERIVITIVES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTNNING THE EXPRESS WRITTEN CONSENT OF BORDERS INC., NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT. 0 COPYRIGHT PENDING ISSUED FOR: PST WARETTAL A REVISION i 9/28/07 12/17/07 SHEET TITLE HVAC PLAN STORE NO. *126 TENANT IMPROVEMEN•1t SHEET NO. H100 ir III STUB 10/10 TA DUCT INTO — ELEVATOR MACHINE ROOM STUB 10/10 EA DUCT INTO -- ELEVATOR MACHINE ROOM 11 1 1 / I 1 ELEVATOR MACHINE ROOM HVAC PLAN SCALE: 1/8"=1 L J }'A_9AA!9!1 "�°"- , 11111- - - - -i11 1 11111 1 r ____1111 111 1---- -1 - - -1 : 11 E ---- 1 11 : 11 E ---- 1 1111 1 1 - - - -- 1 - -_1I1 Ill 1 1 1 11 - - -- 1111r - -- - 11 1 III - - -- -1 -1 1 Ilrll 111 1 1 1 - - -- 1 111 1 -- -- 111 - - - -- 1111 - --a I I I 111l1 111 I l r ---- 1 111 1 - - - I ____I III 1 Ill I 1 r - - - -- 111 - -- -11 I J III 11111 III r- 1 1 1 ---- 1 1 1 1 r ----- iii I JA -- -J Ill !MI III III- - - - -1I 1r- - - - -i11 'IL_ J'�1L- J;1 I W' I w' ill I __ J --- O -MM E momI1 ur - lir 11 U P S I i I � 1 L_J 1 1 I- I _ - J t A 1 1 r 11 — 1 1 1I UP I 1 11 / ` I1 11 � n -- LH- II II II II H II II II II II II II II II u II II II II II II II III, 10 "f A 110°0 10' 111110 1 ° i(:II 11'1ili1T•IT "I' 10 "0 sf�e(d A 110 "0 10" 0 22/22 A t? i ' : - Ji ' RTU -1 0 ROOF A * \ ' 0 1 11.` ''''' �� i4 4 • , 10 0 e 7 INOLNfrOg. i r - 1 , ! ■ AllP4MnA F MEI '' : 4 0 1#7#1 . " WI M 6 A ' , a "7 /, „ _ 0 °0 , r, ' I co ill \ 11 1 k A / r lir- --- A gAl 41 1 ■ . '(/ q r 1 i ,. I _.. - 1 , r , ,-. ,, ,. il 10 • III ' i h 1- $ . 'PIPIT__ 4 100 ^/ . - ® RT IN ROOF .BO.E E h l ■ i a [ VAV -1 12/12 SA 10 "0 12/12 SA ff1f; lPllll llllllll'll'll l� 10 /10 A 10 "0 295 (TYP IN SALES AREA) I n 0 T I TIE S �i A 10' hJ rli `► 11 L. - 10" 1 A �n _ 1 i I 'i.-_;=i.-z -1 - 7 - . I A iiQ'. L 280 — 1 0 "0 Pi I - . (!)--- - RTU- (6-11-- ' 1! -r ... FF H D _ .. z V We il- " AmV .I A 10 0 295 —A , i M Ng ititi HVAC PLAN SCALE: 118".1'-0" ■■ ■■ l 4 �* , 1111 • ono III - 10 ' 0 ,__ 'V •• 1 111 _ — PEI 111=111111111N MN I A 1p'PI Mei 10 „0 r A 10 '21 I A 10 \ � 325 325 ` Nor ::_,I'-._____ i ..._._ r _- 0 °0 J ' F O "0 .: r L 10 "0 A 10'21 A in 3•, 325 4 *irIN 'r )1: 321 ii. , — _ r. ...... .. , F r- - 10 "0 i: :::. 10 "0 1. 1 O ,RTU=3 10 "0 370 (TYP OF lllll 8 Date: HVAC SYMBOLS 120 ROUND DUCTWORK. DIAMETER IN INCHES. 20/12 RECTANGULAR DUCTWORK. SIZE IN INCHES, FIRST NUMBER IS SIDE SHOWN. HIGH EFFICIENCY TAP WITH DAMPER AND J r FLEX DUCT AT DIFFUSER CONNECTION. (SEE BRANCH TAKE -OFF DETAIL ON SHEET H200) DUCTWORK TRANSITION FROM RECTANGULAR TO ROUND. DUCTWORK SIZE TRANSITION, SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN SHOWN EQUALS 4 -WAY. OR AS NOTED RETURN AIR GRILLE SUPPLY OR OUTSIDE AIR DUCT RETURN, RELIEF OR EXHAUST AIR DUCT. 90 DEGREE DUCTWORK ELBOW WITH TURNING VANES. SUPPLY OR OUTSIDE AIR DUCT UP SUPPLY OR OUTSIDE AIR DUCT DOWN RETURN AIR DUCT UP RETURN AIR DUCT DOWN POINT OF CONNECTION - NEW TO EXISTING MANUAL VOL. DAMPER A - TAG B - NECK SIZE C - AIRFLOW (CFM) FIRE DAMPER p�r a oro al TUki ° /1k1 : Ilevisions will require ri r1' w plan l ai. tit'f dit l may y inClud e additional plan review lees. FILE COPY Y N . Plan review swami Is sifted to wore ruld 1 Approval of porstruction dommta does nut authorlz 12/12 EA UP TO EF -1I _J AC -1 8'0 City of Tukwila BUILDING DIVISION A H 8 SEPARATE PERMIT REQUIRED FOR: Ely echanical Dr Electrical - /Plumbing �i Gas Piping City of Tukwila 1 ICI ;II i "liP,i; =� DIVISION 1 - 170 — AC -1 ABOVE CEILING. SEE DETAIL ON SHEET H200 FOR DUCT SIZING AND INSTALLATION. 600 CU -1 ON ROOF ABOVE (TYP 2) MISCELLANEOUS S D AL DN EA EF EX RA RTU SA TYP W/ GENERAL NOTES: REMOTE TEMPERATURE SENSOR THERMOSTAT RETURN DUCT MOUNTED SMOKE DETECTOR DRAWING NOTE REFERENCE ACOUSTICAL LINING DOWN EXHAUST AIR EXHAUST FAN EXISTING RETURN AIR ROOFTOP UNIT SUPPLY AIR TYPICAL WITH IOW coct. CODE COKOPACE. APIPTLO 1. HVAC CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS AND PROVIDE SHOP DRAWINGS AS REQUIRED IN THE SPECIFICATIONS. CONTRACTOR SHALL COORDINATE HVAC DUCTWORK SIZES AND INSTALLATION WITH FIELD CONDITIONS PRIOR TO DUCT COORDINATE ANY REQUIRED MODIFICATIONS TO DUCTWORK SIZES OR ROUTING WITH ENGINEER PRIOR. TO FABRICATION. 2. TEMPERATURE SOSORS ARE TO BE INSTALLED AND WIRED BY THE HVAC CONTRACTOR, MOUNT AT 5' -6° ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. 3, HVAC CONTRACTOR IS RESPONSIBLE FOR LOCATING THERMOSTATS AND TEMPERATURE SENSORS SO AS NOT TO INTERFERE WITH STORE FI OR OTHER EQUIPMENT (IE. COMPUTERS, COPIERS FAXES, ETC.). ALSO COORDINATE INSTALLATION TO ACCOMMODATE SLAT WALL COLUMN FINISH. SEE SHEET Al23 FOR DETAILS. 4. ENERGY MANAGEMENT SYSTEM DRAWING TO BE PROVIDED BY EMERSON CLIMATE TECHNOLOGIES. CONTACT EMERSON FOR INFORMATION REGARDING ENERGY MANAGEMENT SYSTEM. SCOTT D. MARSHALL NATIONAL ACCOUNT MANAGER EMERSON CLIMATE TECHNOLOGIES - SOLUTIONS 3179 STEINRUCK ROAD ELIZABETHTOWN, PA 17022 PHONE: 717- 930 -0808 FAX: 419-735-7605 EMAIL: SCOTT .MARSHALL @EMERSONCLIMATE.COM 5. INSTALL ALL SUPPLY AND RETURN AIR DUCTWORK AS TIGHT TO THE BOTTOM OF STRUCTURE AS POSSIBLE. 6. HVAC CONTRACTOR IS RESPONSIBLE TO NUMBER ALL ROOFTOP UNITS. USE 4 "° VINYL NUMBERS. 7. HVAC CONTRACTOR MUST REPLACE ALL AIR FILTERS IN ROOFTOP UNITS AND FAN POWERED VAV BOXES WITH NEW CLEAN FILTERS BEFORE AIR BALANCING AND PRIOR TO FINAL TURNOVER TO BORDERS. 8. G.C. SHALL FOLLOW ALL CURRENT CODES AND BE LICENSED WITH CITY OR STATE AS REQUIRED. 9. PERMITS SHALL BE SUBMITTED PRIOR TO ANY WORK BEGINNING. 10. ALL SUPPLY AIR DUCTWORK (INCLUDING INTERNALLY LINED DUCTWORK) SHALL BE EXTERNALLY WRAPPED W/ INSULATION. (SEE SPECIFICATIONS) 11. PROVIDE ADDITIONAL DUCT TRANSITIONS W/ RISES AND DROPS TO AVOID OTHER PIPING, DUCTWORK, CONDUITS, STRUCTURAL MEMBERS, ETC AS REQUIRED. 12. DUCT SIZES REPRESENT SHEET METAL DIMENSIONS. 13. DUCT TRANSITIONS SHALL BE MADE WITH A MAXIMUM 15 ANGLE OF DIVERGENCE, 14. ALL BRANCH DUCT SIZES NOT SHOWN ON PLAN SHALL MATCH DIFFUSER TAG NECK SIZE, KEY NOTES SET POINT MUST/TEMPERATURE SENSOR AND CO2 SENSOR, 00 PROVIDE 32/;x0 RA OPENING ON TOP OF LINED RA DUCT. DIFFUSERS AND GRILLES IN TOILET ROOM CEILING SHALL BE CENTERED BETWEEN LIGHT FIXTURES. CU -1, FIRE ALARM / SECURITY ROOM CONDENSING UNIT, FURNISHED BY LANDLORD, INSTALLED BY HVAC CONTRACTOR. REFRIGERANT PIPING FURNISHED AND INSTALLED BY HVAC CONTRACTOR. OD PROVIDE RETURN AIR GRILLE WITH TRANSFER AIR BOOT. SEE DETAIL ON SHEET H200. L=./ 10/10 EA UP FROM El. CONNECT INTO BOTTOM OF 12/6 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 22/22 EA UP FROM E2, CONNECT INTO BOTTOM OF 22/6 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 00 6/22 EA UP FROM E2. CONNECT INTO BOTTOM OF 12/12 EA WITH BOOT CONNECTION. SEE DETAIL ON SHEET H200. 00 38/14 LINED RA UP TO RTU RA CONNECTION IN RISE WITH FLEX CONNECTION AT RTU. 10 46/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU, 11 44/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU. 12 38/18 LINED SA. TRANSITION TO 38/22 RTU SA CONNECTION SIZE IN RISE WITH FLEX CONNECTION AT RTU. 13 VAV THERMOSTAT. SEE EMERSON CONTROL DRAWINGS FOR WIRING OF VAV CONTROLS TO ENERGY MANAGEMENT SYSTEM. Mop - 13z CORPEC IOi RECEIVED DEC 2 2007 PERMIT CENTEh PR 2007.021 INTERIOR FINISH BORDERS INC. EXPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE "ARCHITECTURAL WORKS" AND "'TECHNICAL DOC MDITS" AND ANY DERIVITIVES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTNNING THE EXPRESS WRITTEN CONSENT OF BORDERS INC., NOR ARE THEY TO BE ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING SAID WRITTEN PERMISSION AND CONSENT. 0 COPYRIGHT PENDING ISSUED FOR: PST WARETTAL A REVISION i 9/28/07 12/17/07 SHEET TITLE HVAC PLAN STORE NO. *126 TENANT IMPROVEMEN•1t SHEET NO. H100 SCALE: NONE GAS LINE, UNION, SHUTOFF VALVE & DIRT LEG BY SHELL CONTRACTOR GAS PIPING ON ROOF TO ROOFTOP UNIT BY THE SHELL CONTRACTOR CONDENSATE DRAIN LINE (COPPER) TO NEAREST ROOF DRAIN BY SHELL CONTRACTOR D2� RTU SECTION DETAIL SCALE: NONE HANGER RODS SUSPEND FROM JOIST. (WITH VIBRATION ISOLATORS) CONTROL SECTION (OTHER SIDE OF UNIT) INLET TO FAN SECTION PROVIDE A MINIMUM OF 4 DIAMETERS OF STRAIGHT DUCT FROM DUCT TAKE -OFF. SUPPLY AIR DUCT (SEE PLANS FOR SIZES) INSULATED DUCT WRAP WITH VAPOR BARRIER AROUND SUPPLY DUCT. FLEXIBLE CONNECTION AT AIR INLET CONNECTION. SUPPORT CHANNEL. FAN POWERED VAV BOX DETAIL tlHI ri RTU BY LANDLORD (PROVIDED IN SHELL DESIGN) VENT TRAP • 3' -0" L FLEX CONNECTION 15° MAXIMUM ANGLE (SUPPLY AND RETURN DUCT DROPS) NOTES: 1. CURBS TO BE SET AND LEVELED BY LANDLORD'S SHELL CONTRACTOR. 2. LANDLORD'S SHELL CONTRACTOR TO CUT DECK FOR SUPPLY AIR AND RETURN AIR DUCTS. 3. LANDLORD'S SHELL CONTRACTOR TO INSTALL CURB AND ROOFTOP UNIT. 4. HVAC CONTRACTOR TO INSTALL A FLEXIBLE DUCT CONNECTION BETWEEN RTU AND DUCTWORK. 5. SUPPLY AND RETURN DUCTS ARE TO BE PROVIDED WITH 1" FIBERGLASS "ACOUSTICAL" DUCT LINER BOARD FOR A MINIMUM OF 15' -0" FROM CONNECTION TO ROOF TOP UNIT. 6. DUCT MOUNTED SMOKE DETECTORS ARE FURNISHED BY THE ELECTRICAL CONTRACTOR AND INSTALLED BY HVAC CONTRACTOR IN THE RETURN SECTIONS OF UNIT AS SCHEDULED. SEEE SHEET E150 FOR WIRING AND CONNECTION REQUIREMENTS. 7. HVAC CONTRACTOR IS RESPONSIBLE TO NUMBER ALL ROOFTOP UNITS. USE 4" VINYL NUMBERS. ELECTRIC HEATING COIL. PROVIDE DUCT HANGERS WITHIN 12' OF OUTLET. SUPPLY AIR DUCT (SEE PLANS FOR SIZES) PROVIDE 3' -0" MIN. OF STRAIGHT DUCT FROM UNIT rc� SPRING TYPE VIBRATION ISOLATOR (TYPICAL) SCALE: NONE VOLUME DAMPER r FLEX CONNECTION (TYPICAL) TRAPPED CONDENSATE DRAIN AC- 1 /CU-1 DETAIL MAX. OF 12" TO BRANCH CONNECTION SUPPLY AIR DIFFUSER X" THREADED ROD (TYP) AUTOMATIC LEVEL SWITCH TO ACTUATE CEILING MOUNTED INDICATOR LIGHT UPON RISING WATER LEVEL IN SECONDARY DRAIN PLAN. AC -1 NOTE: AC -1 SHALL NOT BE MOUNTED DIRECTLY OVER FIRE ALARM /SECURITY ROOM - SEE PLAN FOR LOCATION l-- H3 HARD CEILING CLIP. SLIDE CLIP INTO DIFFUSER GROOVE. PROVIDE CLIPS WITH A MAXIMUM 10' SPACING ALONG DIFFUSER. SECURE CLIP TO CHANNEL. PROVIDE A 10" MAXIMUM 10" SPACING BETWEEN CLIPS. 1 -1/2" THICK FIBERGLASS INSULATION W /FOIL FACING GALVANIZED SHEET METAL DUCT CU -1 AIR COOLED CONDENSING UNIT INDICATOR LIGHT 13 FLEXIBLE DUCT MOUNTING DETAIL SCALE: NONE PATE ES -5 EQUIPMENT SUPPORT RAILS - FURNISHED BY HVAC CONTRACTOR, INSTALLED BY LANDLORD'S ROOFING CONTRACTOR PATE PGA-5 PIPE CURB WITH PCC -5 COVER - FURNISHED BY HVAC CONTRACTOR, INSTALLED BY LANDLORD'S ROOFING CONTRACTOR BALL VALVE N.C. TITUS FL30 DIFFUSER WITH TYPE 11 BORDER 1" T.A. FILTER x 1f" ANGLE (TYP) 1" CONDENSATE DRAIN TO NEAREST MOP SINK CEILING CODE REQUIRED DRAIN PAN SHALL BE 1 DEEP AND 3" LARGER THAN UNIT ON ALL SIDES PLENUM CLIP TITUS FBP PLENUM. PRESS PLENUM AGAINST DIFFUSER UNTIL PLENUM CLIPS SNAPS INTO DIFFUSER GROOVE. E-D ENLARGED FLOWBAR DIFFUSER CONNECTION DETAIL SCALE: NONE GALVANIZED ELBOW METAL STRAP CLAMP (TYPICAL) 2 PLACES INSULATED FLEXIBLE CONNECTION (MAX. 5 FT.) IN VERTICAL ONLY E MINIMUM TAKE OFF AREA 1.25 TIMES BRANCH DUCT AREA TRIM CHANNEL FOR PLENUM INLET AS REQUIRED. SCALE: NONE SCALE: NONE 14" HIGH PREFABRICATED, INSULATED ROOF CURB. CURB FURNISHED BY HVAC CONTRACTOR INSTALLATION OF CURB IN COMPLIANCE WITH ROOF MANUFACTURER'S REQUIREMENTS ROOF INSULATION METAL DECK BLOCKING AND LEVELING BY GENERAL CONTRACTOR SCALE: NONE SCALE: NONE METAL STUD AND CHANNEL. FASTEN H3 CLIP TO STUD /CHANNEL WITH A MAXIMUM SPACING OF 10' BETWEEN CLIPS. FLOWBAR DIFFUSER DETAIL - ISOMETRIC VIEW SEE ENLARGED FLOWBAR DIFFUSER CONNECTION DETAIL ON THIS SHEET. METAL STUD AND CHANNEL. FASTEN H3 CLIP TO STUD /CHANNEL WITH A MAXIMUM SPACING OF 10" BETWEEN CLIPS. GYP BOARD (TYPICAL)- SINGLE SLOT 3' FLOW BAR JET THROW DIFFUSER. USE BORDER 11 WITH H3 HARD CEILING CLIPS AND ECX END CAPS. H3 HARD CEILING CLIP SUPPLIED WITH DIFFUSER. INSERT CLIP INTO DIFFUSER GROOVE. SECURE CLIP TO STUD WITH A MAXIMUM SPACING OF 10'. NOTE: SEE ARCHITECTURAL DRAWING A420 FOR ADDITIONAL INFORMATION REGARDING SIDEWALL OPENING IN SOFFIT. FLOWBAR DIFFUSER DETAIL - SIDE VIEW ROOF MOUNTED EXHAUST FAN DETAIL RECTANGULAR TO ROUND "BUCKLEY FITTING' 90° COMBINATION TEE WITH OVAL TO ROUND TAP (IF BRANCH FLOW IS 2/3 OF THRU FLOW) VARIES 2" MINIMUM COLLAR DUCT BRANCH TAKE -OFF DETAIL METAL STUD AND CHANNEL. FASTEN H3 CLIP . 777— TO STUD /CHANNEL WITH A MAXIMUM SPACING OF 10" BETWEEN CLIPS. 1 -1/2" THICK FIBERGLASS INSULATION W /FOIL FACING FLOWBAR DIFFUSER PLENUM. SLIDE PLENUM INTO OPENING SO THAT CLIPS SNAPS INTO DIFFUSER GROOVE. GALVANIZED SHEET VOLUME METAL DUCT DAMPER GALVANIZED ELBOW METAL STRAP CLAMP (TYPICAL) 2 PLACES ROOF MOUNTED EXHAUST FAN RECTANGULAR DUCTWORK RUN ROOFING MATERIAL UP UNDER CURB CAP OPENING BY GENERAL CONTRACTOR COORDINATE FRAMING AND OPENING EXHAUST DUCTWORK BY SIZE WITH HVAC CONTRACTOR HVAC CONTRACTOR - 4" RECTANGULAR TO RECTANGULAR 45 LATERAL FITTING 2-3- ROOFING WORK BY LANDLORD'S ROOFING CONTINUOUS INSIDE FLANGE CONTRACTOR AT GENERAL FOR MOUNTING OF SURFACE CONTRACTORS EXPENSE MOUNTED REGISTER BRANCH DUCT HEIGHT DIMENSION 2" LESS THAN MAIN DUCT HEIGHT DIMENSION SCALE: NONE SHEET METAL ELBOW ACOUSTICAL -- DUCT LINER I RETURN AIR GRILLE, AS SHOWN ON PLAN SCALE: NONE MAX. OF 12" TO BRANCH CONNECTION INSULATED FLEXIBLE CONNECTION (MAX. 5 FT.) IN VERTICAL ONLY FLOWBAR DIFFUSER PLENUM. SLIDE PLENUM INTO OPENING SO THAT CLIPS SNAPS INTO DIFFUSER GROOVE. METAL STUD AND CHANNEL. FASTEN H3 CLhP TO STUD /CHANNEL WITH A MAXIMUM SPACIN OF 10" BETWEEN CLIPS. SINGLE SLOT 3" FLOW BAR JET THROW DIFFUSER. USE BORDER 11 WITH H3 HARD CEILING CLIPS AND ECX END CAPS. 001 cipma\ cOtik en Avy DUCT REGISTER DETAIL SCALE: NONE DUCT REGISTER DETAIL 18" MIN. *TiliTililiTiTaini inniTATi 1111111111111111111111111111 RETURN BOOT DETAIL 10/22 TRANSFER AIR u1A141Sh MITT ue{61usA OUTSIDE DIMENSIONS OF REGISTER FRAME. SEE PLAN FOR DUCT SIZE AND SCHEDULE FOR FRAME SIZE. DUCT WIDTH SAME AS GRILLE WIDTH, SIZE HEIGHT FOR A MAXIMUM OF 300 FPM It LAY -IN CEILING AIR OUTLET f'' A NOV 01 2007 PEHivil OLIN ER PROJECT NO. 2007.021 INTERIOR FINISH BORERS INC. DPRESSLYRESEMES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE R ARCHIECIURAL WOES" AND 'TECHNICAL DOCUMENTS' AND ANY DER1VI11VES THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED, CHANCED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONS NT OF BORDERS UIC.. NOR ARE THEY TO BE ASSIGNED TO ANY PARTY YIIINCUT FIRST OBTAUI NG SAID %Ima PERMISSION AND CONSENT. p CCPYRIGHT PENDING ISSUED FOR: PERMIT SUBMITTAL 9/2A/07 SHEET TITLE MECHANICAL DETAILS STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. H2O0 GRILLE, REGISTER AND DIFFUSER SCHEDULE HVACICONTTRACTTORNSTALLED BY TAG SERVICE MAKE MODEL FRAME /BORDER FASTENING TYPE MODULE SIZE NOTES/ ACCESS. A CEILING SA TITUS OMNI TYPE 3 - LAY IN - 24" x 24" A,B B CEILING SA TITUS OMNI TYPE 3 - LAY IN - 12" x 12" A,B,G C SIDEWALL SA TITUS 300RS TYPE 1 - SURFACE TYPE A NECK SIZE + 1X1" SEE PLAN A,C D SIDEWALL SA TITUS FL3O BORDER 11 H3 CLIPS 3" SINGLE SLOT 4' LONG F H A E ' El CEILING EA TITUS 350RL TYPE 1 SURFACE TYPE A NECK SIZE + 1/4' SEE PLAN A,C E2 CEILING EA TITUS 350RL TYPE 3 - LAY IN 1110 NECK SIZE 2° SEE PLAN A,C RG CEILING RA TITUS 50F TYPE 3 - LAY IN NECK SIZE + 2° SEE PLAN A,D FURNISHED AND INSTALLED EXHAUST FAN SCHEDULE BY HVAC CONTRACTOR TAG AREA SERVED LOCATION MAKE MODEL DRIVE TYPE CFM ESP SONE RATING MOTOR H.P. ELECT. VOLT/PH NOTES/ ACCESS. EF -1 REST ROOMS ROOF GREENHECK GB -091 -4 ADJUST. V -BELT 500 0.50" 7.3 1/4 115V/10 A THRU E EF 2 CAFE PANTRY ROOF GREENHECK GB -091 -4 ADJUST. V -BELT 800 0.25" 8.8 1/4 115V/10 A THRU E EF 3 ELEVATOR MACHINE ROOM CEILING GREENHECK CSP -A200 DIRECT 200 0.25' 1.3 WATTS 1AT 115V/10 A,C,F OUTSIDE AIR REQUIREMENTS ROOM PURPOSE FLOOR AREA (SQ FT) ASHRAE OUTSIDE AIR REQUIREMENTS SYSTEM NUMBER OUTSIDE AIR (CFM PER UNIT) CFM PER SQ. FT REQUIRED CFM SALES AREA 20,205 .20 4,041 RTU -1 1,400 RTU -2 1 400 RTU -3 RTU-4 1,400 960 CAFE SEATING AREA 1,436 ,20 288 CAFE PANTRY 414 0.20 83 STOCKROOM 1,240 0.15 186 OFFICES 934 20 CFM PER PERSON 200 TOILET ROOMS 400 50 CFM PER PERSON 200 TOTAL = 4,798 TOTAL = 4,940 VAV BOX SCHEDULE - COOLING ONLY TAG MARK SERVICE MANUFACTURER MODEL PRIMARY AIR MARK INLET SIZE MAX AIR (CFM) MIN AIR (CFM) MAX PD ("WO) REMARKS VAV -1 SORT ROOM _ TITUS DESV 10 "0 1140 290 0.35 1 VAV -2 MGRS AND CASH OFFICE TITUS DESV 6 "0 340 100 0.25 1 VAV -3 OPEN OFFICES TITUS DESV 8 "0 690 185 0.30 1 VAV -4 TOILET ROOMS TITUS DESV 8 11 0 550 185 0.25 1 VAV -5 PANTRY TITUS DESV 10 "0 1110 290 0.35 1 FAN POWERED VAV BOX SCHEDULE TAG LOCATION MODEL PRIMARY AIR FAN SECTION ESP MARK SERVICE MANUFACTURER INLET SIZE MAX AIR (CFM) MIN AIR (CFM) MAX PD ('WG) AIR FLOW CFM PD ( WG) HP VOLTAGE REMARKS VAV -6 CAFE SEATING TITUS DTFS -E 14 "0 2255 565 0.40 2055 0.50 3/4 277V/10 1 FAN -COIL UNIT SCHEDULE FURNISHED BY LANDLORD; INSTALLED BY HVAC CONTRACTOR TAG LOCATION MAKE MODEL CFM ESP FAN HP VOLT/ PHASE COOLING CAPACITY NOTES/ ACCESS. TOTAL MBH ROWS REF AC -1 FIRE ALARM / SECURIT! ROOM LENNOX CB3OM21/26 600 0.30" 1/5 208V/10 18.7 3 R -22 A,B,C,D AIR COOLED CONDENSING UNIT SCHEDULE INSTALLED BY HVAC CONTRACTOR TAG UNIT SERVED LOCATION MAKE MODEL NOMINAL COOLING CAPACITY ELECTRICAL DATA NOTES/ ACCESS. CU - 1 AC - 1 ROOF LENNOX 13ACD -018 1.5 TONS 208V/10 A THRU I WEATHER DATA CITY NAME TUKWILA LOCATION WASHINGTON LATITUDE 47.0° LONGITUDE 122.0° ELEVATION 386.0 FEET SUMMER DESIGN DRY -BULB TEMPERATURE 80.0 °F SUMMER DESIGN WET -BULB TEMPERATURE 64.0 °F WINTER DESIGN DRY -BULB TEMPERATURE 26.0 °F ATMOSPHERIC CLEARNESS NUMBER 0.95 AVERAGE GROUND REFLECTANCE 0.20 ROOFTOP UNIT SCHEDULE NOMINAL TONS 15.0 15.0 15.0 16.0 S.A. E.S.P. HP E.A.T. CFM IN. W.C. DB /WB 5975 0.5 5.0 77.0/62.5 162.6 6000 5965 6085 FAN DATA COOLING DATA 0.5 1.25 7,5 77.0/62.5 SENS. MBH TOTAL MBH FUEL TYPE 185.0 NAT. GAS 0.5 5.0 77.0/62.5 162.6 185.0 NAT. GAS 180 5.0 77.0/62.5 162.6 185.0 NAT. GAS 180 HEATING DATA INPUT OUTPUT MBH MBH 180 146 146 146 146 HTG. STEPS 2 2 2 2 POWER V -0 -HZ 460 -60 -3 460 -60 -3 UNIT MIN. MCA O.A. 40 40 1400 1400 S.A. CONN R.A. CONN SIZE SIZE 38/22 38/22 38/18 38/18 460 -60 -3 40 1400 38/22 38/18 460 -60 -3 43 960 38/22 38/18 MARK RTU -1 RTU -2 RTU -3 RTU -4 SERVICE SALES AREA SALES AREA SALES AREA SALES AREA MANUFACTURER MODEL AAON AAON AAON AAON RM RM RM RM ALL RTU'S FURNISHED AND INSTALLED BY LANDLORD WEIGHT REMARKS LBS. A -F A -F A -F A -H 1650 1650 1650 1681 REMARKS A - 14" PREFABRICATED ROOF CURB B - FACTORY INSTALLED DISCONNECT AND 115V CONVENIENCE OUTLET C - POWERED EXHAUST D - PROVIDE WITH 410A OR HFC 134A REFRIGERANT E - UNIT CAPACITIES SHALL BE BASED ON A.R.I. CONDITIONS F - CONTROLS BY EMERSON, PROVIDE WITH TERMINAL STRIP TIE -IN G - FACTORY INSTALLED VFD (SUPPY FAN) FOR VAV RTU H - HOT GAS BYPASS REMARKS 1. UNITS SHALL BE FURNISHED WITH ALL STANDARD FEATURES AND THE FOLLOWING ACCESSORIES; 1/2" FOIL FACED INSULATION, FACTORY MOUNTED 277/24 VOLT TRANSFORMER W/ FUSING ON PRIMARY, AND 24 VOLT ELECTRONIC DAMPER ACTUATOR WIRED TO A TERMINAL STRIP. CONTROLLER TO BE FURNISHED AND INSTALLED BY AUTOMATIC TEMPERATURE CONTROL CONTRACTOR. REMARKS 1. UNITS SHALL BE FURNISHED WITH ALL STANDARD FEATURES AND THE FOLLOWING ACCESSORIES; 1/2" FOIL FACED INSULATION, ECM MOTER, FAN CONTROL BOX FUSE, 24 VOLT MAGNETIC CONTROL, AIR FLOW SWITCH, INTERLOCKING DOOR DISCONNECT SWITCH, LINE FUSE, SERIES FAN OPERATION, AND A 24 VOLT ELECTRONIC DAMPER ACTUATOR. CONTROLLER TO BE AS REQUIRED BY THE AUTOMATIC TEMPERATURE CONTROL SYSTEM. NOTE /ACCESSORY DESIGNATION A - NO SUBSTITUTIONS ACCEPTED B - DIRECTIONAL BLOW CLIPS (DB) AS REQUIRED BY DIRECTIONAL ARROWS ON PLAN C - OPPOSED BLADE DAMPERS D - CODE A X" x X" x X" ALUMINUM GRID E - 4' -0" FBP -3O PLENUM 10 "0 INLET F - "ECX" END CAPS G - RAPID MOUNT FRAME H - SPECIFY CURVED DIFFUSER SEE ARCHITECTURAL DRAWINGS FOR SOFFIT RADIUS NOTE : rS, FOR P 3 Q (3 ) x,63 2 X LY I�(:117�1;�iY, rtJ{�1 �.'�•�ia Nr�.�.iT���; t :i`v �� -f1 =.tit, „ NOTE /ACCESSORY DESIGNATION A - COMBINATION HEAT /COOL THERMOSTAT WITH SUB -BASE B - THROW AWAY FILTER C - INSULATED CABINET D - UNIT WEIGHT = 136 lb NOTE /ACCESSORY DESIGNATION A - UNIT CAPACITIES SHALL BE BASED ON A.R.I. CONDITIONS B - HIGH AND LOW PRESSURE SWITCHES ON REFRIGERANT SYSTEM C - THERMOSTAT CONTROLLED CRANKCASE HEATER D - FILTER -DRYER ON COMPRESSOR REFRIGERANT SYSTEM E - CAPACITY CONTROL NOTE /ACCESSORY DESIGNATION A - SAFETY DISCONNECT SWITCH - NEMA 1 - MOUNTED & WIRED B - GRAVITY OPERATED BACK DRAFT DAMPER C - AMCA SEAL & U.L. LISTED D - 14' PRE MANUFACTURED ROOF CURB WITH DAMPER TRAY E - ALUMINUM RUB RING F - REVERSE ACTING THERMOSTAT CONTROL F G H I 0 PA '�' \ om 0 . li \ f 15 ) ,_ 0 DEGREE LOW AMBIENT CONTROL PATE MODEL ES 8' (MIN.) PREFABRICATED SUPPORT RAILS U.L. LISTED UNIT WEIGHT = 122 lbs. P; :( _ ! /' E.) (. f 0 ! t NOV 01 2007 PLfr1Mft (ENTER PROJECT NO. 2007.021 INTERIOR FINISH BORDERS INC. EXPRESSLY RESERVES HIS COMMON LAW AND STATUTORY LAW COPYRIGHTS AND OTHER PROPERTY RIGHTS FOR THESE 'ARCHITECTURAL WORKS* AND 'TEo UCAL DOCUMENTS' AND ANY DERINTIVES'THEREOF. THESE DRAWINGS AND DOCUMENTS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER FOR ANY USE WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN CONSENT OF BORDERS INC.. NOR ARE THEY TO BE ASSIGNED 10 ANY PARTY WITHOUT FIRST WINNING SAID 'ARIT1EFi PE IAISSON AND CONSENT. COPYRIGHT PENDING ISSUED FOR: PERMIT SUBMITTAL 9/28/07 SHEET TITLE MECHANICAL SCHEDULES STORE NO. #126 RELO TENANT IMPROVEMENT SHEET NO. H300