HomeMy WebLinkAboutPermit M07-234 - SIDHU HOMESSIDHU HOMES
4645 S 148 ST
M07 -234
Parcel No.: 0042000140
Address: 4645 S 148 ST TUKW
Suite No:
Tenant:
Name:
Address:
SIDHU HOMES
4645 S 148 ST , TUKWILA WA
Owner:
Name: SIDHU HOMES INC
Address: 4224 S 148TH ST , TUKWILA WA
Contact Person:
Name: GARY SINGH
Address: 4224 S 148 ST , TUKWILA WA
City, if Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Contractor:
Name: AV HEATING & AIR CONDITIONING
Address: 35817 9 AV SW , FEDERAL WAY WA
Contractor License No: VHEATHA953D8
DESCRIPTION OF WORK:
MECHANICAL FOR NEW 5278 SF SFR
Value of Mechanical: $4,500.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
MECHANICAL PERMIT
EOUIPMENT TYPE AND QUANTITY
1
0
0
1
2
0
0
0
0
5
0
1
0
0
* * continued on next page **
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 244 -1900
Phone: 253 815 -8475
Expiration Date: 03/28/2009
M07 -234
11/10/2008
05/09/2009
Fees Collected: $211.95
International Mechanical Code Edition: 2006
Boiler Compressor:
0-3 HP /100,000 BTU 0
3-15 HP /500,000 BTU 0
15-30 HP /1,000,000 BTU.. 0
30-50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 1
Wood/Gas Stove 1
Water Heater 1
Emergency Generator 0
Other Mechanical Equipment 0
doc: IMC-10 /06 M07 -234 Printed: 11 -10 -2008
Permit Center Authorized Signature:
Signature:
Print Name:
doc: IMC-10 /06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performan4e pf work. I am authorized to sign and obtain this mechanical permit.
Permit Number: M07 -234
Issue Date: 11/10/2008
Permit Expires On: 05/09/2009
C Dtj Date: t t - t l/ - o T!
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender
or abandoned for a period of 180 days from the last inspection.
M07 - 234 Printed: 11 -10 -2008
Parcel No.: 0042000140
Address: 4645 S 148 ST TUKW
Suite No:
Tenant: SIDHU HOMES
y'
1: ** *BUILDING DEPARTMENT COND1TiONS * **
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number: M07 -234
Status: ISSUED
Applied Date: 11/01/2007
Issue Date: 11/10/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 -3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
7: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE
GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that
the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests.
8: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum
distance of 4- inches shall be maintained above the controls with the strapping.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206 - 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
doc: Cond -10/06 M07 -234 Printed: 11 -10 -2008
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
doc: Cond -10/06
Date: I i ),(7/0 e
M07 -234 Printed: 11 -10 -2008
Tenant Name:
Property Owners Name:
Mailing Address:
Company Name:
Mailing Address:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
/tllp: //www.ci.tukwila.wa.us
Mailing Address: AS Ab e VC_
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print"
Site Address: % '- i Sp H S ck
9—
ONO 4 -10 , %arc,
2.24 Sbi 14 PA, Si s•
Name: G A (L'y S t G N Day Telephone: 2011- Zy 4•-19 n Q
atY E -Mail Address: ti a 0, pv...Ca,} .1 le{'Fax Number. 20 �p State 413 3 g $ $
5 1DHU oP4 S r rut_
ArN Atokrve_
Zip
Day Telephone: 206— 1 V4-11 .-1c t a
o,0:4_ ,1 G,-,........5,4 , ,J Fax Number: /.0 -kill Al--k I(
Contractor Registration Number: S VIM U 4.k VI$ v ?Jo Expiration Date: t5 % — 3b- 2 00 a.
Contact Person: S
E -Mail Address:
Company Name: lLlo N T E $1 G'J
Mailing Address: t &6 Ak 16 toil, 0 ,dy-l9
CitY
Contact Person: .�'►��! 1^'►1� c{1,�
E -Mail Address:
Company Name: & N N E Y ii ( -
Mailing Address:
King Co Assessor's Tax No.: !NI) y' OO 01 If 6
Suite Number: Floor:
New Tenant: ❑ Yes ❑ ..No
City
State Zip
Day Telephone: 2 V b - O c{ Z.
Fax Number:
-- ru (4.41Lfk3 etG ciO'o6
Zip
City State
City state zip
Contact Person: ?"l i Y Day Telephone: 2S3 - 4 13 9 1313
E -Mail Address: Fax Number. Z. — ° ` 3 5 1 3 7 3
Q:NppliationsWomm- Applieztiesu On Lineu -2006 - Penn! Appliwion.doe
Revised: 9-2006
eh
Page 1 of 6
$ ,. F9
eA
y*f
Y,.
EOM
(r `Y d ", },` "%
C •
' ate ia'
p
2 5" .s i -'
1 r ��
for
1111
IMIIIIIIIIIMMI11111111
IIIAIII 111111/41111
T
xz
59
ill
,f
a
II
Valuation of Co Project (contractor's bid price): $ at �e
J ( P ) � Existing Building Valuation: $ 96 Scope of Work (please provide detailed information): IQ etJ .S V..00 . FQ _ 1 Re swot seu Co,
Will there be new rack storage? ❑ Yes [it. No If yes, a separate permit and plan submittal will be required.
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, nrovide the following:
Lot Area (sq ft): _ g l9J . 7] , . oor area of principal dwelling: 502,. SF: Floor area of accessory dwelling:
*Provide documentation that shows the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact Handicap.
Will there be a change in use? ❑ Yes 51 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm (j, None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes id No
If 'yes , attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q: AppliationsWonns- Applications On tne3 -2006 - Permit AppGarim.doe
Revised: 9 -2006
bh
Page 2 of 6
Scope of Work (please provide detailed information):
Water Distric(
❑ Tukwila VWater District #125
.‘ai ...Water Availability Provided
ewer District
...Tukwila Va1Vue
❑ ...Sewer Use Certificate ..Sewer, Availability Provided
ub itted with Application (mark boxes which apply):
.. Civil Plans (Maximum Paper Size — 22" z 34 ")
.Technical Information Report (Storm Drainage)
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 72 hours
❑ ght -of -way Use - No Disturbance
...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
Q' ..Total Cut 5 D cubic yards
.Total Fill cubic yards
❑` Yietky Sid ' 64)
❑ ...Cap or Remove Utilities 0 ..
D Improvements ❑ ..
Traffic Control ❑ ..Control ❑ ..
❑
...Backflow Prevention - Fire Protection
Irrigation _
Water
�1 . D �t'a 12 )
[ ] ...Permanent ater Meter Size...
❑ ...Temporary Water Meter Size ..
❑ ...Water Only Meter Size
❑ ...Sewer Main Extension. Public _
❑ ...Water Main Extension Public
If
Q:tApplieaCe *tFom - Applieetiom On Linet3- 2006 - Permit Application :doe
Revised: 9 -2006
hh
❑ •• Work in Flood Zone
Storm Drainage
Abandon Septic Tank
Curb Cut
Pavement Cut
Looped Fire Line
Call before you Dig: 1- 800 - 424 -5555
WO #
WO #
WO #
Private
Private
❑ .. Highline
❑ .. Renton
`iJ .. Geotechnical Report
❑ .. Maintenance Agreement(s)
S •F C
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
❑ .. Renton
❑ .. Seattle
Septic System:
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
❑ .. Right -of -way Use - Profit for less than 72 hours
❑ .. Right -of -way Use — Potential Disturbance
❑...Deduct Water Meter Size
❑...Traffic Impact Analysis
❑...Hold Harmless — (SAO)
❑ ...Hold Harmless — (ROW)
❑ .. Grease Interceptor
❑ .. Channelization
Trench Excavation
Utility Undergrotmding
FINANCE INFORMATION
Fire Line Size at Property Line
❑...Water ❑ ...Sewer
Monthly Service Billing to:
Name:
Mailing Address:
Water Meter Refund/BilIing:
Name:
Mailing Address:
Number of Public Fire Hydrant(s) I
❑ ...Sewage Treatment
WA T4 h :s /• /
Day Telephone:
City
Day Telephone:
City
y411/4 St ufi'•
State
State
Zip
Zip
Page 3 of 6
) RIVIA TI
•
MECHANICAL CONTRACTOR INFORMATION
Company Name: 1 4
Mailing Address:
Contact Person: . V4, r.t Day City
Telephone: 2
E - Mail Address:
Fax Number. av ZS 3
Expiration Date P)
Contractor Registration Number: VHEATH A qs 3 .08
Valuation of Mechanical work (contractor's bid �
price): $ � 500
Scope of Work (please provide detailed information):
Use Residential: New ....[" Replacement ....
Commercial: New .... ❑ Replacement .... 0
Fuel Type: Electric 0 Gas ,,,.j Other:
Air Handling Unit Incinerator — Comtn/lnd
<10,000 CFM
Q: AppGestions On Lme13 -2006 - Permit Applimion.doe
Revised: 9 -2006
bh
State
s
Indicate type of mechanical work being installed and the quantity below:
Unit � . e: e Unit . e- . ,. Unit T , :: •,..
BoilerlC'brir ressor
0-3 HP /100,000 B TU
Furnac:ew100K BTU Evaporator Cooler ••* • kit ; 1 V t •. J
Floor Furnace
Diffuser 3-1 IMP /500,000 BTU
Ventilation Fan Connected Thermostat
to Single Duct 15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor rn Wood/Gas Stove Mounted Heater Ventilation Syate r 30 -50 HP/1,750,000 BTU
Appliance Vent - Hood and Duct
Emergency
Repair or Addition to Incinerator - Domestic Generator
O
Heat/Refrig /Cooling ther Mechanical ? R
System Equipment
50+ HP /1,750,000 BTU
S 1 ,T4 :
— 9 Soo/
Zip
•
Page 4 of 6
T.
Fi e . yz
Bathtub or combination
bath/shower
to.
J
Ff:ctu%e; a . o` s
Drinking fountain or water
cooler (per head)
a�
n �turr 7
1 i °
Wash fountain
® s
Gas piping outlets
Bidet
Food -waste grinder,
commercial
$
Receptor, indirect
waste
Clothes washer, domestic
1
Floor drain
Sinks
it l
Dental unit, cuspidor
Shower, single head trap
1
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Rain water system — per
drain (inside building)
Repair or alteration of water
piping and/or water treating
equipment
Water heater and/or
vent
Repair or alteration
of drainage or vent
piping
Additional medical gas
inlets/outlets — six or more
Medical gas piping system
serving one to five
inlets/outlets for specific gas
PL BING" AND GAS PIPING ItERMIT INFO4048,1 I
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
6 u K -Al- SoA)S ( (w...46 is Iwc.
Cxt2bciv%adz . = U}-rt -- of S 23
City state zip
Contact Person:_'4C.� SR_ - Day Telephone:_ /7 4 b i V31
E -Mail Address. Fax Number: 3b0-- $ Zg f �a3
Contractor Registration Number: (3 utk$ PIPOW:505 Expiration Date:
Company Name:
Mailing Address: P. b • ((o $. ZZ
o
Valuation of Plumbing work (contractor's bid price): $
5 60 9:9
Valuation of Gas Piping work (contractor's bid price): $ 5 DO `
O2
Scope of Work (please provide detailed information): AJeC../ Si 1„i k_
Building Use (per Intl Building Code): JitC7-4 o G •
Occupancy (per Int'l Building Code): 5; " ge_ l7 r si e-(4
Utility Purveyor: Water: lAk-1 env LSO f " /25'. Sewer: IA: / h t
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Q:NppliutionsWenns- Applications On Line \3 -2006 - Penh Appliatimdoe
Revised: 0.2006
bh
Re5404-* ee
Page 5 of 6
iM 1
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AG ...
Signature: `` Date: t 41 03
Print Name: Gure6. ;o► Day.Telephone: o?Od — Z Yq // O d
Mailing Address: £/ 9 sot, b ' / vs TU7( SJ/C A G�J - eig b
` City stat
Date Application Accepted:
IIIoIk'+
Q:tApplicaticns\Pomn- APplicstian On rinra3 -2006 - Pem it MDliationdoe
Raised: 9 - 2006
hh
Date Application Expires:
I Staff Initi
Page 6 of 6
RECEIPT NO: R07 -02393
Initials: JEM
User ID: 1165
Payee: SIDHU HOMES
SET TRANSACTIONS:
Set Member Amount
ACCOUNT ITEM LIST:
Description
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
SET ID: 1101 SET NAME: SIDHU HOMES
D07 -409 3,047.07
M07 -234 36.39
PG07 -291 76.50
TOTAL: 3,159.96
Payment Check 1981
PLAN CHECK - RES
PW BASE APPLICATION FEE
PW PLAN REVIEW
SET RECEIPT
TOTAL:
000/345.830 2,809.96
000/322.100 250.00
000/345.830 100.00
TOTAL: 3,159.96
Payment Date: 11/01/2007
Total Payment: 3,159.96
TRANSACTION LIST:
Type Method Description Amount
3,159.96
3,159.96
Account Code Current Pmts
Project:
t 'S--' O /7 /-/o
rr7 S
Type of Inspection: \
, / N
Address:
4 /(0 1-/5 <5
/ 4' °.y
Date Called:
Special Instructions:
Date Wanted:
67 — 2 6 - 05 a
Requester:
Phone No:
a o6 zs‘ y -ice v v
7-2.5 L A
INSPECT NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 0 -
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36
INSPECTION RECORD
Retain a copy with permit
pproved per applicable codes. Corrections required prior to approval.
COMMENTS:
J 4 i 7 0vn, /elP j i ;/3 /
IDate C
G —2 — 5
REINSPECTION FE REQUIRED. Prior to inspection, fee must be
t 6300 Southcenter lvd., Suite 100. Call to schedule reinspection.
I Rec '•t No.: 'Date:
Project l ^ itu / � - o P i
Type of spectio _ e
Address: � _ . • r`i 0 Zi �
I IInstructions:
D a d 1 ,�,Q 7 V `-+ � .r
/
Special
Date Wanted:
I —Z3 -0 Aline
Requester:
Phone
26 I-44 -(90o
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
INSPECTION NO.
INSPECTION RECORD M o ,7 234
Retain a copy with permit
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
C 0 (2' k Kr -e 6.1-Ge
3
'Inspector
Date:
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
'Date:
A.
B.
A.
B.
fi
CITY OF TUKWILA,..)
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
RESIDENTIAL HEATING AND VENTILATION COMPLIANCE FORM
(Complete Sections I and II for Group R Occupancies 4 Stories or Less)
Project Name: 44V ffiii ; tOvit4
Site Address: ��i'r? `� 1
I. WASHINGTON STATE ENERGY CODE HEATING DESIGN METHOD (select A, B or C below):
❑ System Analysis — W.S.E.C. Chapter 4 (submit documentation)
❑ Component Performance Approach — W.S.E.C. Chapter 5 (submit documentation)
C. a Prescriptive Option — W.S.E.C. Chapter 6 (for prescriptive, complete the following calculation):
House Square Footage (heated space): 5.2 75
X 20 BTU/h
/o S 560 Maximum BT
❑ Heating System Installed, (check system type below):
1. ❑ Electric Resistance
2. ❑ Electric (forced air)
3. t I:2 Other Fuels as heat pump) Cy Of Tukwila
BUILDING DIVISION
II. WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (select A or B below):
❑ Ventilation by Performance or Design Method - W.S.V.I.A.Q. Section 302 (submit documentation).
❑ Prescriptive Ventilation Options - W.S.V.I.A.Q. Section 303 (select one of the following):
❑ Ventilation using Exhaust Fans (Section 303.4.1.)
❑ Exception for outdoor air inlets — Forced air heating system w/interior doors undercut 1/2"
2. • Ventilation integrated with Forced Air System (Section 303.4.2.)_
❑ Ventilation using Supply Fan (Section 303.4.3.)
4. ❑ Ventilation using Heat Recovery System (Section 303.4.4.)
Prescriptive Minimum/Maximum Outdoor Air Calculation specified in Table 3 -2 (see reverse side of form).
1.
3.
1. House Square Footage: 52.7$
2. House Number of Bedrooms: a
3. Required Outdoor Air Table 3 -2: Minimum - /6 cfm
Maximum - 2 Y5 cfm
Effective: 7/1102
tapplicationstheatlrp end ventilation system — form h4 (7 -2002)
MECHANICAL PERMIT APPLICATION NO.:
r
P nit Center/Building Division:
206 - 431 -3670
Public Works Department:
206 - 433 -0179
Planning Division:
206 -431 -3670
BUILDING PERMIT APPLICATION NO.: PO4L1 o
FILE COPY
PIyrmit Nee
NOV - 6 2003
KtVltvvcu rut
alinEciWILIANCE
APPROVED
RECEIVED
CITY OF TUIM1"
NOV 01 20 1..
PERMIT CENTER
AAD1.9224
Fan Tested CFM
a 0.25" W.G.
Minimum Flex
Diameter
Maximum Length
Feet
Minimum Smooth
Diameter
Maximum Length
Feet
Maximum
Elbows'
50
50
80
4 inch
y$ g`"" ''` -.
6 inch
5 inch
25
No Limit
15
4 inch
6 inch
5 inch
70
No Limit
100
3
3
3
�
0 H -�4
7wV �
5 inch
yw� ;.�� , � @ ® F �'�,. F,` �.
6 inch
s
_,� '- .ttr'�:._ . -.
NA
�,,m.�z*,a+`4r.. x u�y x�ky"3� • S
15
..a_ ... i!'W. .. • c:
50
�_ _ ..: � i 8 t�' ::i.
No Limi
�
3
3
�'�e'�.. ��t
100
t � i .;�f�� , �a..
125
5 inch
.P�'�, � ,�i-ia .:Y:: ,_. a� e,.,
6 tech
�yy
TABLE 3 -2
VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES OR LESS
Minimum and Maximum Ventilation Rates: Cubic Feet Per Minute (CFM)
Floor
Area ft2
<500
4001 -5000
6001 -7000
8001 -9000
Bedrooms
2 or less
Min
50
95
115
135
Max
75
143
173
203
3
Min
65
r
110
130
150
Max
98
165
195
225
4
Min
80
125
145
165
Max
120
188
218
248
5
Min
95
140
160
180
Max
143
210
240
270
6
Min
110
155
175
195
Max
165
233
263
293
7
Min
125
170
190
210
Max
188
255
285
315
8
Min
140
185
205
225
Max
210
278
308
338
*For residences that exceed 8 bedrooms, increase the minimum requirement listed for 8 bedrooms by an additional 15 CFM per
bedroom. The maximum CFM is equal to 1.5 times the minimum.
TABLE 3 -3
PRESCRIPTIVE EXHAUST DUCT SIZING
1. For each additional elbow subtract 10 feet from length.
2. Flex ducts of this diameter are not permitted with fans of this size.
06 -03 -2009
GARY SINGH
4224 S 148 ST
TUKWILA WA 98168
RE: Permit No. M07 -234
4645 S 148 ST TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the
Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does
allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests
must be in writinff and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from
being taken.
In the event you do not call for the above inspection and receive an extension prior to 07/22/2009 , your permit will become null and
void and any further work on the project will require a new permit application and associated fees.
Thank you for your cooperation m this matter.
Sincerely,
Bill Rambo
Permit Technician
R tco,.4
xc: Permit File No. M07 -234
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
09 -08 -2008
GARY SINGH
4224 S 148 ST
TUKWILA WA 98168
RE: Permit Application No. M87 -234
4645 S 148 ST TUKW
Dear Permit Applicant:
In reviewing our current permit application files, it appears that your permit application applied for on 11/01/2007 , has not been
issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical
Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and
void. Your permit application expires on 10/27/2008 .
If you choose to pursue your project, a written request for extension of your application addressed to the Building Official,
demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 10/27/2008. If it is
determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date.
In the event we do not receive your written request for extension, your permit application will become null and void and your project
will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely, 4 4i9
eV
er Marshall
Permit Technician
xc: Permit File No. M07 -234
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila. Washington 9R1RR • Phnnp• 21h- a31 -VS71) • Far- 2nM- 4z1 -2AA,C
1
July 22, 2008
Gurdip Singh
4224 S 148 St
Tukwila WA 98168
V
Cizy of Tukwila
Department of Community Development Jack Pace, Director
RE: Request for Permit Application Extension #2
Development Permit Application No. D07 -409
Mechanical Permit Application No. M07 -234
Plumbing/Gas Piping Application No. PG07 -291
Electrical Permit Application No. EL07 -641
Sidhu Homes — 4645 S 148 St
Dear Mr. Singh:
This letter is in response to your written request for an extension to Permit Application Nos.
D07 -409, M07 -234, PG07 -291, and EL07 -641. The Building Official has reviewed your letter
and considered your request to extend the above referenced permit applications. The City of
Tukwila Building Division will be extending the expiration date of your permit applications for
an additional 90 days from the previously extended expiration date (through October 27, 2008) as
requested.
If you should have any questions, please contact our office at (206) 431 -3670.
File: Permit No. D07 -409, M07 -234, PG07 -291, & EL07 -641
P:\Permit Center\Extension Letters\Pemrit Applications\2007'D07-409+ Application Extension #2.doc
jem
Jim Haggerton, Mayor
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
10
Q3A
ctiit OW+ cAl,
Com
D EVELo? N iet .
0 Q 1 JVC-wI LA
‘AJ ti)44, Ato C-41 dL• Dol—tocy
_ O evvie- crth
6�t1 ,4 b- ''23qi �G 6 a
61"e- 4-0`c-P-k■iA" -VA/ ,
weJicu..-5 -re-1,01424-, dAse-t-t-c-s , vita
cvs_ok. --tuark2 scsaA;49 9J71,.All
e;a4
ce-
_ b
PO 71'
6e-rr
06 -05 -2008
GARY SINGH
4224 S 148 ST
TUKWILA WA 98168
RE: Permit Application No. M07 -234
4645 S 148 ST TUKW
Dear Permit Applicant:
In reviewing our current permit application files, it appears that your permit application applied for on 11/01/2007 , has not been
issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical
Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and
void. Your permit application expires on 07/28/2008 .
If you choose to pursue your project, a written request for extension of your application addressed to the Building Official,
demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 07/28/2008. If it is
determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date.
In the event we do not receive your written request for extension, your permit application will become null and void and your project
will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
xc:
440
fer Marshall
it Technician
Permit File No. M07 -234
Cizy of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
April 10, 2008
Gurdip Singh
4224 S 148 St
Tukwila WA 98168
RE: Request for Permit Application Extension
Development Permit Application No. D07 -409
Mechanical Permit Application No. M07 -234
Plumbing/Gas Piping Application No. PG07 -291
Electrical Permit Application No. EL07 -641
Sidhu Homes — 4645 S 148 St
Dear Mr. Singh:
This letter is in response to your written request for an extension to Permit Application Nos.
D07 -409, M07 -234, PG07 -291, and EL07 -641. The Building Official has reviewed your letter
and considered your request to extend the above referenced permit applications. The City of
Tukwila Building Division will be extending the expiration date of your permit applications for
an additional 90 days from the original application expiration date (through July 28, 2008) as
requested.
If you should have any questions, please contact our office at (206) 431 -3670.
Sincerely,
fer Marshall
P it Technician
City of Tukwila
Department of Community Development Jack Pace, Director
File: Permit No. D07 -409, M07 -234, PG07 -291, & EL07 -641
P :\Permit Center\Extension Letters\Permit Applications V007007-409+ Application Extension.doc
Jam
Jim Haggerton, Mayor
6300 Southcenter Boulevard. Suite #100 • Tukwila. Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 4.31 -366
L
( c'ctfe L
M Oil
;2,Y Cat
S a.,Y,. eCk ; 2 , kest- -y_ eLt• ct , P"'"Aj V A'CCI(111''
fYf o?'2 Pgd7.- ., E LF 4.0Y/
a r e- tete piri,,tt ci,-elS X. 50 /ci
02rxi S A ¥ A'
S'Ir .Jive,
ulk e..v-,=.t- aYtzti , , c,--,
'‘'` v45s\\ d- 44 76
eta" e '
�►�►�- 9 ° P •
r
otki god
Cate MO a
4 44 / Vig I 173 11J. 4-1JX■v
OQ' OB La7g .C),ry- 014141q
03 -05 -2008
GARY SINGH
4224 S 148 ST
TUKWILA WA 98168
RE: Permit Application No. M07 -234
4645 S 148 ST TUKW
Dear Permit Applicant:
In reviewing our current permit application files, it appears that your permit application applied for on 11/01/2007 , has not been
issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical
Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and
void. Your permit application expires on 04/29/2008 .
If you choose to pursue your project, a written request for extension of your application addressed to the Building Official,
demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/29/2008. If it is
determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date.
In the event we do not receive your written request for extension, your permit application will become null and void and your project
will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
J fer Marshall
Permit Technician
xc: Permit File No. M07 -234
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
DEPARTMENTS:
Buil g Division
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M07 -234 DATE: 11 -01 -07
PROJECT NAME: SIDHU HOMES
SITE ADDRESS: Lj1rL S 148 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
Fire Prevention
Public Works ❑ Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
Incomplete n
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
l�l
DATE:
DATE:
Planning Division
Permit Coordinator
n
DUE DATE: 11 -06-07
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
❑ No further Review Required
n
DUE DATE: 12-04-07
Not Approved (attach comments) n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: