Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-241 - REGENCY CLEANERS
REGENCY CI.F.ANF:RS 950 ANDOVER PK E #19 EXPIRED 05-04-08 M07 -241 Parcel No.: 2623049105 Address: Suite No: 950 ANDOVER PK E TUICW Tenant: Name: REGENCY CLEANERS Address: 950 ANDOVER PK E, STE 19 , TUKWILA WA Owner: Name: NATIONWIDE LIFE INS Address: REAL ESTATE INVESTMANT , ONE NATIONWIDE PLAZA Contact Person: Name: JOSEPH BAYS Address: 950 ANDOVE RPK E, STE 19 , TUKWILA WA Contractor: Name: TOTAL MACHINERY INC Address: 7110 ZIRCON CT SW , LAKEWOOD WA Contractor License No: TOTALMI936JW DESCRIPTION OF WORK: CONSTRUCT BOILER ROOM, ISNTALL 40 HP BOILER AND ASSOCIATED EQUIPMENT (RENEWAL OF PERMIT M06 -112). Value of Mechanical: $5,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 City.df Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Fees Collected: $211.95 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 1 0 0 0 0 0 * *continued on next page ** Permit Number: M07 -241 Issue Date: 11/06/2007 Permit Expires On: 05/04/2008 Phone: Phone: 206 267 -3466 Phone: 206 226 -3370 Expiration Date: 04/16/2009 Boiler Compressor: 0-3 HP/100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 1 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -241 Printed: 11 -06 -2007 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be compile The granting of construction or Signature: Print Name: doc: IMC -10/06 ermit does not pre erformance of work. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.cttukwila.wa.us Permit Number: M07 -241 Issue Date: 11/06/2007 Permit Expires On: 05/04/2008 Date: t t , di 1/01 ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulatinc I am authorized to sign and obtain this mechanical permit. Date: /I /U 0 / This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -241 Printed: 11 -06 -2007 Parcel No.: 2623049105 Address: Suite No: Tenant: 950 ANDOVER PK E TUKW REGENCY CLEANERS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. MOT -241 ISSUED 11/06/2007 11/06/2007 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tulcwila Building Department (206 - 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so doc: Cond -10/06 M07 -241 Printed: 11 -06 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 nun) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4 -4) 18: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 19: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 20: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -241 Printed: 11 -06 -2007 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: *07 M07 -241 Printed: 11 -06 -2007 CITY OF TUKWIL& Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cttukwila.wa.us SITE LOCATION �J �� King Co Assessor's Tax No.: 46.Zf71,7,5 Site Address: 7 �' �°' / c 1, �¢4 ,C Suite Number: Floor: g/fi�°/�s New Tenant: Yes ..No Property Owners Name: Mailing Address: Tenant Name: CONTACT PERSON 7 who do we contact when your permit is ready to be issued Name: �Qf�‘ Mailing Address: / 5Z E -Mail Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** .511° /1Cc MECHANICAL PERMIT APPLICATION MECHANrCAL CONTRACTOR INFORMATION Company Name: Ve/�� �/ /e Q� Mailing Address: 7 7 (2/ cJ� �// �O,�t ✓l! Contact Person:A4 /d d/r E -Mail Address: Contractor Registration Number: /©/ illy ��67� Al # Q:'Applications\Forms- Applications On Linel3 -2006 - Mechanical Permit Application.doc Revised: 4-2006 bh Day Telephone: e' — 2o 7 TO I lidr O /, RI 4 10:://, rpAr, A/o/we 4.ver e Fax Number2J ' ` ra�I ® -� ©� City State Zip Day Telephone: axe 727.6 Fax Number: Expiration Date: #/ifriH' ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Recor Company Name: Mailing Address: City Day Telephone: Fax Number: State State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record City Day Telephone: Fax Number: Zip Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler / Diffuser. 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ Sco a of Wo k (please provide detailed information): / , , '/ c 1f0/_/ - - i a i., t�lG f Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....a Replacement .... ❑ Fuel Type: Electric ❑ Gas ...4 Other: Indicate type of mechanical work being installed and the quantity below: CATION cation Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limita j �io I i. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. to possible revision by the Permit Center to comply with current fee schedules. BUILDING OW OR AU H s D AGENT: Signature: Print Name: /� Mailing Address: 7 0i f Date Application Accepted: ttMo- Date Application Expires: Staff Initials: i Q:\Applications\Fonns- Applications On Line\3 -2006 - Mechanical Permit Application.doc Revised: 4-2006 bh C ity (M-H( 00 2.1 qota2 iv / 01 vi ?fit 0 6 /7-1-- 3S t t �- 3q2. Date: /�17 Day Telephone: Ffie — 26 7- j1 I State Zip ?v( (ec9 0j JPage 2 of 2 Parcel No.: 2623049105 Address: 950 ANDOVER PK E TUKW Suite No: Applicant: REGENCY CLEANERS Payee: JOSEPH BAYS ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.cLtukwila.wa.us RECEIPT Receipt No.: R07 -02432 Payment Amount: $.02 Initials: JEM Payment Date: 11/06/2007 11:25 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Cash .02 Account Code Current Pmts 000/322.100 .02 Permit Number: M07 - 241 Status: APPROVED Applied Date: 11/06/2007 Issue Date: Total: $.02 doc: Receiot -06 Printed: 11 -06 -2007 Parcel No.: 2623049105 Permit Number: M07 -241 Address: 950 ANDOVER PK E TUKW Status: APPROVED Suite No: Applied Date: 11/06/2007 Applicant: REGENCY CLEANERS Issue Date: Receipt No.: R07 -02431 Initials: JEM User ID: 1165 Payee: BANA INC TRANSACTION LIST: Type Method Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Amount Payment Check 1263 102.76 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES Account Code Current Pmts 000/322.100 102.76 Total: $102.76 Payment Amount: $ 102.76 Payment Date: 11/06/2007 11:24 AM Balance: $0.02 doc: Receiot -06 Printed: 11 -06 -2007 04 -04 -2008 JOSEPH BAYS 950 ANDOVE RPK E, STE 19 TUKWILA WA 98188 RE: Permit No. M07 -241 950 ANDOVER PK E TUKW Dear Permit Holder: Based on the above, you are hereby advised to: Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/04/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall t Technician Permit File No. M07 -241 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 License Information License TOTALMI936JW Licensee Name TOTAL MACHINERY INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602268961 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 7110 ZIRCON CT SW Address 2 City LAKEWOOD County PIERCE State WA Zip 98498 Phone 2062263370 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/16/2007 Expiration Date 4/16/2009 Suspend Date Separation Date Parent Company Previous License KACESI *9630M Next License Associated License Business Owner Information Name Role Effective Date Expiration Date PARK, HEE TAE PRESIDENT 04 /16/2007 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 AMERICAN CONTRACTORS IND CO 100021884 04/06/2007 Until Cancelled $12,000.00 04/13 /2007 COLONIAL AM Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TOTALMI936JW 11/06/2007