Loading...
HomeMy WebLinkAboutPermit M07-243 - GATEWAY BUILDING 7 - HVAC UPGRADEGATEWAY BLDG 7 12720 GATEWAY DR EXPIRED 11-28-08 M07 -243 Parcel No.: 2716000070 Address: Suite No: 12720 GATEWAY DR TUKW Citf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: GATEWAY BLDG 7 - HVAC UPGRADE Address: 12720 GATEWAY DR , TUKWILA WA Owner: Name: RREEF AMERICA REIT II CORP/ Address: PO BOX 4900 #207 , SCOTTSDALE AZ Contact Person: Name: CHRIS LEE Address: 7717 DETRPOT AV SW , SEATTLE WA Contractor: Name: MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU DESCRIPTION OF WORK: REPLACE (1) PACKAGED ROOFTOP UNIT. Value of Mechanical: $68,700.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * *continued on next page ** M07 -243 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 768 -4266 Phone: 206 -763 -9400 Expiration Date: 12/31/2008 M07 -243 12/04/2007 06/01/2008 Fees Collected: $719.39 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 - HP /500,000 BTU 0 15-30 HP/1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 12 -04 -2007 I hereby certify that I have read and e governing this work will be complied doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Center Authorized Signature: " ) O V 7 J 1 JL 9 J Date: I The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatini construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: ( i \ .J( Date: l -1-1°‘4 I 0-7 Print Name: <L \ S� Permit Number: M07 -243 Issue Date: 12/04/2007 Permit Expires On: 06/01/2008 L ed this permit and know the same to be true and correct. All provisions of law and ordinance: whether specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 -243 Printed: 12-04 -2007 Parcel No.: 2716000070 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12720 GATEWAY DR TUKW GATEWAY BLDG 7 - UVAC UPGRADE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -243 ISSUED 11/13/2007 12/04/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *PLUMBING AND GAS PIPING * ** 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) doc: Cond -10/06 M07 -243 Printed: 12 -04 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 19: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M07 -243 Printed: 12 -04 -2007 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us cL/ ka2,\ I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 240 H 107 M07 - 243 Printed: 12 -04 -2007 • %woe CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 2 - 1 I bo O c O 0 - 1 O Site Address: / 2-1 70 6 o " °C L pc 4 1"7 2 Suite Number: $t.D b r) Floor: Tenant Name: O7o► 2w vim,, SCA 4 6 *1 - J? C q Up rc iLQ New Tenant: ❑ Yes ' No Property Owners Name: 6.rc�e. •F 0-J Mailing Address: 121 ZO C --Q.t..7 a.. p K• 4 Zoo 1 1...J P4 gSst &V State Zip //�� Day Telephone: (VL )76% e - 4 426, Mailing Address: 1- 11 - b,�-? - Y l A Sul. S W £42J C J A 9V/0 Name: l..r LY L S City State Zip E -Mail Address: Fax Number: GENE R CONTRACTOR INFORMATION - (Contractor Inform�tioofor Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: Mailing Address: Contact Person: E - Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Q:IApplications\Fotms- Applications On LineU -2006 - Permit Application.doc Revised: 0-2006 bit City City Da ' - - • tone: State City Day Telephone: mber: Expiration Date: Zip ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Mnb ENGINEER OE- RECORD - All plans must be wet stamped by Engineer of Record State Zip Fax Number: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air andling Unit >10,000 CFM ' Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION ( Company Name: ` 1 JO r a mail/ Mailing Address: 1 in I> ° 14 St..) C,hr)s Le3L Contact Person: E -Mail Address: Contractor Registration Number: WA (O 0C .5 q e 0 e-V stp.M -L c.1A 4 k/0 City State Zip Day Telephone: CLoC) 76 5e - Ya t' 6 Fax Number: Expiration Date: I Z ' 3/ — O 1 — Valuation of Project (contractor's bid price): $ (OF lOb y Scope of Work (please provide detailed information): he 1G.C_R. 1 QAti. 0.3 ed rOO -FAQ , S> s o nY\ Q.C. o re c of Q-c.t sc ■l i ".-t 0.r e . c kY1 c o.,.\ -Gs ✓ ne-w (cro p-ft Use: Residential: New .... ❑ Replacement ... ❑ Commercial: New .... ❑ Replacement ... Fuel Type: Electric Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q:1ApplicationsWorms- Applications On Line13 -2006 - Permit Application.doc Revised: 4-2006 bh Page 4 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signature: Date Application Accepted: t t AUTHORIZED AGENT: Print Name: Mailing Address: - 1 - 1 Q: Applications\Forms- Applications On line\3-2006 - Permit Appliation.doc Revised: 4 bh City Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). Date: 1/ -12- d1' Day Telephone: ( L (D� " aly S=w *ckA w r■ q$ ibc3 state Zip Date Application Expires: g[ (�b� Staff Initials: !-- Page 6 of 6 RECEIPT NO: R07 -02473 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Initials: JEM Payment Date: 11/13/2007 User ID: 1165 Total Payment: 301.88 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. SET ID: S000000898 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount EL07 -679 164.00 M07 -243 137.88 TOTAL: 301.88 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 1495 301.88 TOTAL: 301.88 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR PLAN CHECK - NONRES Account Code Current Pmts 000.322.101.00.0 164.00 000/345.830 137.88 TOTAL: 301.88 4916 11/13 9710 TOTAL 301.88 City of Tukwila Receipt No.: R07 -02651 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2716000070 Permit Number: M07 -243 Address: 12720 GATEWAY DR TUICW Status: APPROVED Suite No: Applied Date: 11/13/2007 Applicant: GATEWAY BLDG 7 - IIVAC UPGRADE Issue Date: Initials: gm Payment Date: 12/04/2007 01:02 PM User ID: 1165 Balance: $0.00 Payee: MACDONALD- MILLER FACILTY SOLUTIONS, INC. TRANSACTION LIST: Type Method Description Payment Check 1522 581.51 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES Amount Account Code Current Pmts 000 /322.100 581.51 Total: $581.51 Payment Amount: $581.51 5663 12/04 9710 TOTAL 581.51 doc: Receipt-06 Printed: 12 -04 -2007 10 -01 -2008 CHRIS LEE 7717 DETRIOT AV SW SEATTLE WA 98106 RE: Permit No. M07 -243 12720 GATEWAY DR TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, xc: er Marshall it Technician Permit File No. M07 -243 City of f Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 11/28/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 i May 23, 2008 Christopher K Lee MacDonald- Miller 7717 Detroit Ave SW Seattle WA 98106 RE: Request for Extension Mechanical Permit No. M07 -243 Gateway Bldg 7, HVAC Upgrade —12720 Gateway Dr Dear Mr. Lee, This letter is in response to your written request for an extension to Permit No M07 -243. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 180 days from the date of expiration (through November 28, 2008) as requested. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. M07 -243 jcm fer Marshall it Technician city of Tukwila Department of Community Development Jack Pace, Director P:\Pemut Centci Extension Letters \Pemtits\200TM07 -243 Permit Extension.doc Page 1 of 1 Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 / - 4 E-c-,e1VED CZ!) 008 MacDonald - Miller ox 4 2 FACILITY SOLUTIONS coin � at pn i Macl9gg - Miller Facility Solutions 7717 Detroit Ave SW Seattle, WA 98106 05 -13 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Attn: Bob Benedicto Subject: Extension for Permit No. M07 -243, 12720 Gateway Drive, Tukwila Dear Mr. Benedicto: I am writing to request a 90 day extension for Permit No. M07 - 243. Additional time is requested to resolve wiring interface requirements with the rooftop A/C unit smoke detector and existing duct smoke detectors in the building. We are coordinating our efforts with the fire alarm subcontractor, building owner and the Fire Inspector. If you have any questions, you can reach me at 206 - 768 -4266 or Steve Flink, the MacDonald - Miller project manager for this job, at 206 -396 -8657. Thank you, 0(04 Christopher K. Lee MacDonald - Miller Facility Solutions, Inc. -b '9 4000 P.O. Box 47983 7717 Detroit Avenue SW 206.763.9400 Seattle, WA 98146 Seattle, WA 98106 www.macmiller.com 05 -08 -2008 CHRIS LEE 7717 DETRPOT AV SW SEATTLE WA 98106 RE: Permit No. M07 -243 12720 GATEWAY DR TUKW Dear Permit Holder: City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such detennination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 06/01/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, x c: fer Marshall 't Technician Permit File No. M07 -243 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M07 -243 DATE: 11 -13 -07 PROJECT NAME: GATEWAY BUILDING 7 SITE ADDRESS: 12720 GATEWAY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Oi uil f/ r B ing Divi Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prev f Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator DUE DATE: 11- 15-07 Not Applicable ❑ No further Review Required DATE: DATE: C n DUE DATE: 12 -13-07 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company Previous License DIVCOI *988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SIGMUND, FREDRIC PRESIDENT 12/31/2002 KOPET, TYLER SECRETARY 12/31/2002 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MACDOFS980RU 12/04/2007 DAMPER LEGEND SYMBOL DESCRIPTION- POWERED SYMBOL DESCRIPTION -NON POWERED 1 1/2 HOUR VERTICAL COMBINATION 'FIRE /SMOKE 212 FPM) OR EQUAL FD HFD FD • HFD Q FD . 1 1/2 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER FSD $i GREENHECK FSD (2000 GREENHECK FSD 312 (3000 FPM) OR EQUAL 1 112 HOUR HORIZONTAL COMBINATION FIREISMOKE FSD 212 FPM) OR EQUAL GREENHECK DFD 150 (HORIZONTAL MOUNT) OR EQUAL 3 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER HFSD 4 GREENHECK (2000 GREENHECK FSD 312 (3000 FPM) OR EQUAL 1 1/2 HOUR TUNNEL CORRIDOR COMBINATION FIREISMOKE GREENHECK DFD 350 OR EQUAL 3 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER TFSD . GREENHECK CFSD 212 -1 OR EQUAL • 3 HOUR VERTICAL COMBINATION F1RE/SMOKE GREENHECK DFD 350 (HORIZONTAL MOUNT) OR EQUAL CEILING RADIATION DAMPER FSD GREENHECK FSD 231 OR EQUAL 3 HOUR HORIZONTAL COMBINATION FIRE/SMOKE GREENHECK CRD-2 OR EQUAL BACKDRAFT DAMPER WD 330 OR WD HFSD GREENHECK FSD 231 OR EQUAL SMOKE DAMPER BDD BAR 04 L GREENHECK (VERT) -100 (HORIZONTAL) OR EQUAL BAROMETRIC RELIEF DAMPER (.05 OPNG PRESSURE SHOWN) SD a GREENHECK SMD 202 OR EQUAL MOTORIZED CONTROL DAMPER \ RUSKIN CBD2 NO SUBSTITUTE ALLOWED VOLUME DAMPER MD . GREENHECK VCD -23 OR EQUAL SMOKE CONTROL MOTORIZED DAMPER GREENHECK SMD 301 OR EQUAL SHOP FABRICATED, W/ LOCKING QUADRANT SCD 4 INTERLOCK WITH FIRE ALARM BY ELECTRICAL CONTRACTOR ACCESS DOOR AD > 18" x 18" MINIMUM THROUGH BUILDING CONSTRUCTION BY GENERAL CONTRACTOR GENERAL NOTES: COMBINATION FIRE/SMOKE DAMPER REQUIREMENTS (UNLESS OTHERWISE NOTED): - CLASS II - 165° FUSIBLE LINK - FAIL - CLOSE, 120V ACTUATOR - ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR - INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR FIRE DAMPER REQUIREMENTS: - BLADES OUT OF AIRSTREAM ON MEDIUM PRESSURE DUCTS -165 F FUSIBLE LINK - CLASS II DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL ELECTRICAL ROUND SHEETMETAL WRAPPED WI INSULATION (2 ") SUPPLY CFM 14/12 ' 120W ESP (IN) RPM SOUNDLINE SHEETMETAL (1 " LINING) VOLT/ PH CLEANROOM QUALITY DUCTWORK RTU -101 14/12 SL 14/12 0 , 20,000 3,680 SHEETMETAL WRAPPED WI INSULATION (2 ") 1.2 BARE FLAT OVAL SHEETMETAL 4 @1 HP @ 1 HP EACH ' 14/12 W 14/12$ 150 NEW, REPLACE EXIST, 1 -5 BARE ROUND SFiE'ETMETAL CARRIER 48DF-064 SERIES# 640PA SERIAL# Y883274 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") CARRIER 48DF -064 SERIES# 640PA SERIAL# Y883274 120 14/12 EXPOSED QUALITY SHEETMETAL DUCTBOARD (1 " FIBERGLASS) 14/12 0 14/12 DE CARRIE!R48TJD014SERIES# 601 QE SERIAL# 4194G30497 SOUTH WING EXAMPLE OF NEW CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4194G30497 EXAMPLE OF NOT IN CONTRACT (NIC) 1 ; 12 14/12 EXAMPLE OF DEMO FLEX DUCT EXISTING xxxxxxxx x x x x x x x x EXAMPLE OF EXISTING FLEX CONNECTOR ; : =`12 PACKAGED GAS /ELEC AIR CONDITIONING ROOFTOP UNIT SCHEDULE UNIT NO. MFG & MODEL NO. AREA SERVED FANS WEIGHT (LBS) ELECTRICAL NOTES SUPPLY CFM MIN OA (CFM) SUPPLY MOTOR (HP) ESP (IN) RPM POWER EXH MOTOR VOLT/ PH MCA RTU -101 CARRIER 48AKTO50DSQ611 HM EAST WING 20,000 3,680 1@30 HP 1.2 1242 4 @1 HP @ 1 HP EACH ' 6 460/3 150 NEW, REPLACE EXIST, 1 -5 RTU -102 CARRIER 48DF-064 SERIES# 640PA SERIAL# Y883274 NORTH WING CARRIER 48DF -064 SERIES# 640PA SERIAL# Y883274 60 EXISTING RTU -103 CARRIE!R48TJD014SERIES# 601 QE SERIAL# 4194G30497 SOUTH WING RTU 103 CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4194G30497 EXISTING UNIT NO. MFG & MODEL NO. COOLING HEATING FILTERS COOLING !COOLING TOTAL (TONS) TOTAL (MBH) COOLING SENS (MBH) EERI SEER IPLV REFER TYPE HEAT INPUT (MBH) HEAT OUTPUT (MBH) 1 STAGES ( #) AFUE (%) ! CITY ( #) ' SIZE (IN) RTU -101 CARRIER 48AKTO5ODSQ611 HM 50 600 456 9.3 9.5 R -22 800 656 5 82 5 20x20x4 RTU -102 CARRIER 48DF -064 SERIES# 640PA SERIAL# Y883274 60 RTU 103 CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4194G30497 FITTING GENERAL NOTES PIPING MATERIAL SCHEDULE: PIPING SIZE MATERIAL JOINT NATURAL GAS 112" 2 „ SCH 40 BLK STL ASTM A53 A OR B THREADED, FLANGED, SOCKET WELDED SCH 40 BLK STL BUTT WELDED 2-1/2" 10" ASTM A53 A OR B FLANGED, 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 IBC, IMC, AND UPC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 4. SLOPE ALL INDIRECT DRAINS AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 5. HANGERS AND SUPPORTS 'FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2006 IMC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 7 PROVIDE SHUT -OFF VALVES AT ALL' EQUIPMENT CONNECTIONS. 8 PROVIDE UNION, GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 9 FOR CONDENSATE PIPING PROVIDE TRAPS WITH A MINIMUM SEAL 2" GREATER THAN THE FAN OPERATING STATIC PRESSURE AT ALL COOLING COIL CONNECTIONS. 10 PROVIDE MINIMUM 1" AIR' BREAK FOR ALL CONDENSATE PIPE TERMINATIONS AT DRAINS. 11 PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. 0 0 cf c E as 0 z 0 0 c 0 N 0 NOTES: 1. ELECTRICAL DISCONNECT SWITCH AND POWER WIRING BY ELECTRICAL CONTRACTOR. 2. VFD MOTORS 3. FEATURES AND OPTIONS INCLUDED: - COMFORTLINK CONTROLS WITH VISUAL SCROLLING MARQUEE DISPLAY - HIGH GAS HEAT WITH STAINLESS STEEL HEAT EXCHANGER/BURNER - ALICU CON D AND EVAP - DIFFERENTIAL DRY -BULB ECONOMIZER - FACTORY INSTALLED POWEi EXHAUST (11,700 CFM) - HOT GAS BYPASS - LONWORKS TRANSLATOR CONTROLS INTERFACE - RETURN AIR SMOKE DETECTOR - 115V FACTORY WIRED CONVENIENCE OUTLET - CO2 SENSOR 4. MAXIMUM SOUND POWER LEVEL OF 99 DECIBELS RATED IN ACCORDANCE WITH ARI STANDARD 270 5. NEW UNIT WEIGHT (6,658 LI3S) IS LESS THAN UNIT REPLACED (6,800 LBS). NO STRUCTURAL REVIEW REQUIRED PER CITY OF TUKWILA. HVAC GENERAL NOTES 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. 4. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 112 °' 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR' BARRIER (R -4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). 5. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 112 " FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 6. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2006 IBC. 7. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 8. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT' MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 9. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 10.MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE' PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 11. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 12.OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 13.COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 14.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGG EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE. CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ABBV FULL NAME ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM HVAC ABBREVIATIONS EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD-MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUITAMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE-UP AIR NOMINAL DRAWING SHEET INDEX NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM0.01S SITE IMAP TM2.03 ROOF PLAN AND ELEVATION - HVAC LEGAL DESCRIPTION APN # 2716000070 LEGAL DESCRIPTION: GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89 -1 -SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER CONTACT LIST TITLE NAME COMPANY PHONE NUMBER FAX NUMBER PROJECT MANAGER PROJECT ENGINEER SHEETMETAL FOREMAN AIR BALANCE FOREMAN ELECTRICAL FOREMAN CONTROLS FOREMAN REFRIGERATION FOREMAN STEVE FLINK CHRIS LEE LARRY HARBISON BRAD SHARP MIKE MCGIVERN SABRINA WORKMAN STEVE HARBISON OPERATIONS MANAGER GREG COLEMAN MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER RREEF 253- 681 -3172 206- 768 -4266 206 - 423 -4294 206 - 768 -4112 206- 768 -4046 206 -768 -4074 206- 768 -4032 206 -788 -4404 206 -768- 253 -681 -3173 206- 768 -4267 206 - 768 -4295 206- 768 -4047 206 - 768 -4075 206- 768 -4033 SCOPE OF WORK REPLACE (1) EXISTING PACKAGED ROOFTOP UNIT, INCLUDES NEW M -M CUSTOM FABRICATED CURB ADAPTER. RECONNECT EXISTING NATURAL GAS LINE TO NEW ROOFTOP UNIT. ELECTRICAL DISCONNECT/CONNECT FOR NEW ROOFTOP UNIT. 'RATE PERMIT IT D FOR: REQUIRED 0 mechanical Electrical Y e Plumbing g. Gas Piping City Of Tukwila I B` Il _Dlr { DIVISION ABBV FULL NAME OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP TSTAT TC TOD TOS TV TWG TWR TYP UNO VD VFD S 133RD ST SITE 48TH AVE S INTERURBAN AVE S VICINITY MAP NO SCALE OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER 1 t�'!� �r SS Y� . fi t'` flCFeG r �. rr I oF No a prior app ov7il Of work °ri�hOUt 'D Tuk,..vila B.Uildina Division Revisions will require a new p" ?.n subr I NO I and may include additional plan rev1eAk, foe FILE ; Penult No. 0 Plan review IS arbfact to anon and omissions. Approval of construction documents does rut authorize the violation of any adopted code or ordinance. Receipt of approved Reid Copy and melons is ed: BY DUWAMISH RIVER Date: (° k it ' City of Tukwila BUILDING DIVISION REVIE \fq ED FOR CODE COMPLIANCE \ Ec APP RO pED Q\ ; r 2N E Q 10Q,N1 t r• FIS1 RECEIVED CITY OF TUKWILA NOV 1 3 zu 7 PtroviI I GEN TER MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206 -767 -6773 www.macmiller.cam WA Lic No: MACDOFS980RU PERMIT SET REVISIONS: GATEWAY BLDG 7 12720 GATEWAY DR S TUKWILA WA 98168 SCHEDULES - HVAC ENGINEER: LAST REVISED: C LEE 11-12-07 CHECKED BY: DATE PLOui B GEZON 11-12-07 CAD: ISSUE DATE: D IKERD DRAWING NUMBER: E- 0182 - 7376672 -00 NOT ISSUED FOR CONSTRUCTION SHEET NUMBER: 0 0 0 N co h 0 z Lit 0 0 Q CN N N) N {fj Ica 0 0 0 cn 0 0 0 C) JWAV FR E PI 0 MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 - 767 -6773 www.macmiller.com WA Lilo No: MACDOFS980RLI 11-12-07 DATE GATEWAY BLDG 7 12720 GATEWAY DR S TUKWILA WA 98168 SITE MAP ENGINEER: O LEE CHECKED BY: B GEZON D IKERD LAST REVISED: 11 - 12 - 07 DATE PLO iuty: 11 - 12 - 07 ISSUE DATE: DRAWING NUMBER: E-0182 —7376672 —00 NOT ISSUED FOR CONSTRUCTION NOV 2 8 2008 leNeD cave coreuPNce E � t1Va RECEIVED CITY OF TUKWILA NOV 1 3 7007 ljCr���u E VENTER SHEET NUMBER: TM�OIS 0 N CD CO N M N U7 0 w 0 0 N) co e 0 GATEWAY BLDG 7 i , , , , 12720 GATEWAY DR S TUKWILA WA 98168 ROOF PLAN AND ELEVATION - HVAC ENGINEER: LAST REVISED: C LEE 11-12-07 CHECKED BY: DATE PLOTTED: B GEZON 11-12-07 CAD: ISSUE DATE: D IKERD DRAWING NUMBER: E-0182-7376672 —00 NOT ISSUED FOR CONSTRUCTION SHEET NUMBER: , ‘ 0 C F j 2 1 ROOF PLAN - 1-IVAC SCALE: Vs = '--0 3. 1 222E 1 71 L. 1 G J GENERfri NO FLAG NOTES: 1 1. NOT ALL ROOF—MOUNTED EQUIPMENT IS SHOWN. CARRIER WEATHER MAKER SINGLE—PACKAGED 40—TON ROOFTOP U\IT MODEL# 45DF-054. SER1ES# 640PA. SERIAL # X88 [FXIRTING] REPLACE W/50 TON MODEL CARRIER 45AKTO5DSQ611HM. CARRIER WEATHER MAKER SINGLE—PACKAGED 60—TON O01-' OP UNIT. MODFI # 48DF-064. SERIES# 640PA. SERIAL# Y883774. [EXISTING] CARRIER WEATHER MAKER SINGLE—PACKAGED ROOFTOP UNIT. MODEL # 48 SERIES# 601 SERIAL 4194G30497. [EXISTING] A—A TM2.0 r SCREEN WALL 1 x K It 11 )( 11 )( )( it )( 1 1 l( )1 ) 1 ( m ll )( ) 1 )c RTU —101 It II li )4 11 )( II PI h 11 )t 11 it 11( II N. 11 )t 11 )t 11 )( II / 11 1 11 1 [ I I I ii EA 2 RTU- 1 01 RTLI-101 NORTH ELEVATION NO SCALE AA, 2..L4 E \ \ 1 EX NOV 28 Z008 r---1-C-B-------11EVVED FOR CODE COMPLIANCE \, APPROVED NOV 3 P NC ay Of lukwila BUILDING Dr\-135,TON ' RECEIVED CITY OF TUKWILA NOV 1 3 70:: ( PERMIT CENTER MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU PERMIT SET REVISIONS: DATE 11-12-07 0 z 1) D 0 1 1 LL.1 C*1 N (0 (0 N N) 0 0 0 0 uJ cr) (r) 1