Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-253 - MICHAELS
MICHEALS 17400 SOUTHCENTER PY M07.253 Parcel No.: 2623049110 Address: Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us 17400 SOUTHCENTER PY TUKW Tenant: Name: MICHAELS Address: 17400 SOUTHCENTER PY , TUKWILA WA Owner: Contact Person: Name: ERIC KOCH Address: 2150 N 107 ST SUITE 501 , SEATTLE WA Citf Tukwila Name: HEITMAN Address: 191 N WACKER DR STE 2500 , CHICAGO IL Contractor: Name: PHOENIX MECHANICAL CORPORATION Address: PO BOX 2033 , MANCHACA TX Contractor License No: PHOENMC937KT DESCRIPTION OF WORK: RETROFIT EXISTING HVAC UNITS WITH NEW DUCT WORK Value of Mechanical: $40,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 361 -1358 Phone: 512- 291 -0785 Expiration Date: 05/30/2009 Fees Collected: $615.33 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 3 -15 HP /500,000 BTU 15-30 HP /1,000,000 BTU.. 30 -50 HP/1,750,000 BTU.. 50+ HP /1,750,000 BTU Fire Damper Diffuser Thermostat Wood/Gas Stove Water Heater Emergency Generator Other Mechanical Equipment M07 -253 02/26/2008 08/24/2008 0 0 0 0 0 0 0 0 0 0 0 0 doc: IMC /06 M07 -253 Printed: 02 -26 -2008 Permit Center Authorized Signature: The granting of this pe construction or the Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: MOT -253 Issue Date: 02/26/2008 Permit Expires On: 08/24/2008 Date: 141 I hereby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied t , whether specified herein or not. • does not pr -ume to give authority to violate or cancel the provisions of any other state or local laws regulating ce o ', I am authorized to sign and obtain this mechanical permit. Date: 006 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. doc: IMG10 /06 M07 -253 Printed: 02 -26 -2008 Parcel No.: 2623049110 Address: 17400 SOUTHCENTER PY TUKW Suite No: Tenant: MICHAELS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -253 Status: ISSUED Applied Date: 11/26/2007 Issue Date: 02/26/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. M07 -253 Printed: 02 -26 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 17: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 21: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 22: Local U.L. central station supervision is required. (City Ordinance #2051) 23: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 24: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 25: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 26: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Unit heater sprinkler coverage needs to comply with section 8.3.2 and Figure 8.3.2.5 of NFPA 13(2007) 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 31: To schedule all construction fire - related inspections send an e -mail to fireinsprequest ©ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 32: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: Cond -10/06 M07 -253 Printed: 02 -26 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us * * continued on next page ** 33: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 M07 -253 Printed: 02 -26 -2008 Signature: 6./71-- Print Name: .C/ a. / cJrh City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. z /u /a Date: tk doc: Cond - 10/06 M07 -253 Printed: 02 -26 -2008 CITY OF TUKWILA...) Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: Vl q-00 So trTIAGEt.tTrg. pr-m" Tenant Name: t-1 [CR, LS Property Owners Name: Kit .4) SZ VEA:. t T1 Mailing Address: 3 5 35 F eTb'R -c A '5 LV p 5V- ULEV U E k (7 ) $ 00 CQ City State Zip Name: F—'g-1 C 1F -UC-Hr Mailing Address: Z1 SO N , I61 51 91 Gib 1 5 t I11- RA's $ (3 3 City E -Mail Address: C L. ' 7 I Zt (. 6.0 M Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: - co 13E. Contact Person: E - Mail Address: Contractor Registration Number: Company Name: PAC-1 Dcl-G(cri EC11J) -Prt -_ 'pVSl4i U 4 oii'C lhi G Mailing Address: 2- S L . 1 01 'Y" Sit- ' 5Q ( W U Contact Person: . C L44- E -Mail Address: -t C ?AV G i -C rim MECHANICAL PERMIT APPLICATION S- u c Q:Applications'Forms- Applications On Line\3 -2006 - Mechanical Permit Application.doc Revised: 4-2006 bit Mechanical Permit P roject No King Co Assessor's Tax No.: 23 C 4 1 1 667 Suite Number: City Day Telephone: Fax Number: ,(For office use only) New Tenant: J.... Yes 0 ..No Day Telephone: 20 C.P '3(..f ( (' S $ State Zip Fax Number: ZOLP 36e ( 14 G)7 City Day Telephone: Fax Number: Expiration Date: State State Floor: I41 ' 133 Zip City State Zip Day Telephone: ' Cd 3C4 ( 13 5 $ Fax Number: 'Let, - 362 ( 1 4 c27 Zip Page I of 2 Unit Type: Qty , Unit Type: Qty Unit Type: Qty . ;Boiler /Compressors Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ 40 . o 6 a . 6 Scope of Work (please provide detailed information): f--e clz-o - r\ - . x t 5"77 n, (� 1,.J 7 9U C - Us 6 - e-IL Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas.... Other: Indicate type of mechanical work being installed and the quantity below: 61.1 lr`1 f ■tE 'v 1 7U Crt7,v OCL Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: �UC1 - 1 Mailing Address: -1 S O 1N, (O 9"t - 5'L' 50 l 9 11-0 U./i (3 b 133 State Zip Date Application Expires: Date Application Accepted: Q:\Applications\Forms- Applications On Line\3 -2006 - Mechanical Permit Application.doc Revised: 4-2006 bh 44 vp Ul✓rtr Date: ) l f Z [z fG7 Day Telephone: 26 Ce 3 Ca 13 S 8 City Staff Initials: ii Page 2 of 2 Receipt No.: R08 -00530 Initials: JEM User ID: 1165 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049110 Permit Number: M07 -253 Address: 17400 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 11/26/2007 Applicant: MICHAELS Issue Date: Payee: WELLS FARGO, PERSONAL MONEY ORDER TRANSACTION LIST: Type Method Description Amount Payment Check 88132265 498.26 Account Code Current Pmts 000/322.100 498.26 Total: $498.26 Payment Amount: $498.26 Payment Date: 02/26/2008 09:02 AM Balance: $0.00 9119 02/26 9710 TOTAL 498 .26 doc: Receipt -06 Printed: 02 -26 -2008 Receipt No.: R07 -02578 Payee: MICHAELS STORES ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: M07 -253 Address: 17400 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 11/26/2007 Applicant: MICHAELS Issue Date: Initials: WER Payment Date: 11/26/2007 03:11 PM User ID: 1655 Balance: $498.26 TRANSACTION LIST: Type Method Description Amount Payment Check 30002768 117.07 Account Code Current Pmts 000/345.830 117.07 Total: $117.07 Payment Amount: $117.07 5343 11/26 9710 TOTAL 2478.38 doc: Receiot -06 Printed: 11 -26 -2007 Project:, , 1v( , Type of Inspection: . , /J y I 6, , 1 i “.0 ,a A, Ai Add /e1 l p Pate Called: Special Instructions: Date Wa ed: � � l' or �a.m; p.m. Requester: Phone No: M ? - INSPECTION RECORD Retain a "copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION T. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 'Inspect Date:5 I' $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: Project :, i a a to A Type of Inspe,c,tion: Address: /940 Date Called: fc 0 A Special Instructions: / Date Wanted: a, Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tz - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: I lnspec pproved per applicable codes. D Corrections required prior to approval. Amy-/-z Date: OCr El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: COMMENTS: Type of Insp coon: n Address: /`744)aJ i( AA Date Called: ki Sr r-k_1 Special Instructions: Date anted: -' -2Z --of p.m. Requester: ,D ( -.TlD ! — v 0 J 54 .. , i v ‘ ( Jr s 4,.A -('f ' 4E S - 7 --- / . I . I Pro'ect` Q 4 i....i Type of Insp coon: n Address: /`744)aJ i( AA Date Called: Special Instructions: Date anted: -' -2Z --of p.m. Requester: Phone 2 6Y1 - /i ../1 tZ Approved per applicable codes. MY) -2S0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Insp¢ct Date 0558.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: Project: M. Type of Inspection: (o - 14 - Al, eh . Address: / 740() LA-i l e&7 T � Date Called: Special Instructions: / Date Wanted: n _ / Q� a.m. Vim; Requester: Phone No: _5"I2 - 2.40 - 3 0 gI INSPECTI NO. ' �� � PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit 0107 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 5jcpr i $ SQ 4 - e - S ` Z.L- /'� J711 / Inspe frA, Date3 $58.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. (Receipt No.: IDate: Project:,. 41 ,'cA a / .5 Type of Inspection: Address: / 711 Suite #: s' c , en 4"., roz; . , Contact Person: Special Instructions: / Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: / Pre-Fire: Permits: Occupancy Type: '1 6 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTME 444 Andover Park East, Tukwila. Wa. 98188 Approved per applicable codes. Word/Inspection Record Form.Doc 1/13/06 o2r - 0 2- ks 7 - Z PERMIT NUMBERS NT 206-575-4407 ri Corrections required prior to approval. COMMENTS: Fro cfr c.) Al-e/r. fvJ L )14 p _44 464,1 ) F I. A 1) Adi Inspector: ,5) $i$ Date: 3-7,i Hrs.: / 5 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 t Cooling Equipment Schedule Equip. ID Brand Name' I. Model No.' c. ;Capacity Btu/h Total CFM OSA CFM or Econo? c SEER "+ ; .F g _... .. ,IPLV r `` Lbcatio Input Btuh Output Btuh Efficiency Applicant Phone: 913- 742 -5000 RECDIV[t NOV 2 6 2007 PERMIT CENTE i l ' O { i +_i r:'. "f Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Control Location of Service OSA cfm or Econo? Input Btuh Output Btuh Efficiency Applicant Phone: 913- 742 -5000 RECDIV[t NOV 2 6 2007 PERMIT CENTE Heating Equipment Schedule t L-' -==; Michaels Date 11/16/2007 Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency Applicant Phone: 913- 742 -5000 Info Project Address Michaels Date 11/16/2007 Southcenter Pkwy and Minkler Blvd For Building Dept. Use Tukwila, WA 98188 Applicant Name: Duane Henderson - Henderson Engineers Applicant Address: 8325 Lenexa Drive. Suite 400 Applicant Phone: 913- 742 -5000 Project Description Briefly describe mechanical system type and features. 51 s ec nical Summary MECH -SUM Includes Plans 2006 Washington State Nonresidential Energy Code Compliance Form State Nonresidential Energy Code Compliance Forms Packaged DX rooftop untis with supplemental gas heat in loading area. FILE COPY Drawings must contain Pet Writ gl`ance with commissioning requirements - Section 1416 Compliance Option Q Simple Srleifi'r r Q ,-Corr lex-Systerrl r t..; �,.;- terns Analysis, _ _ ` T _ t �.._ t... � : is (See Decision Flowchart- (over) fDr,- qualfications. Use separate MECH- SUM & complex systems.) Equipment Schedules The following Enfofmf y g ' pn is required to be,incorpprated with {tie mechahical equipm4rit'schedules on the plans. For projec s wlthout'pfan fill in t"16-requited iriforniation below.. - 4 . ..ti "1` Revised July 2007 'If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. ` COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 07- 253 _,cem Description See Section 1421 for full description of Simple System qualifications. Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form anical Summary (back) MECH -SUM If Heating /Cooling Constant vol? or Cooling Only: 0 Split system? 51 Air cooled? Q Packaged sys? ❑ <20,000 Btuh? Economizer included? If Heating Only: ❑ <5000 cfm? El <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. otal Ca . wo economize <240,000 Btuh or 10 %? Reference Section 1421 Yes — Yes". Heating /Cooling or Cooling Only Yes Yes C ection 1423 Reference • Simple System _ Allowed (section 1420) Ye Yes Yes • Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. RECEIVEr NOV 262007 PERMIT CENTEI- Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Miahaele Date 11/16/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule a. a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency a. a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans MP1.1 yes 1412.2 Deadband control Indicate 5 degree deadband minimum 1n?1 n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types MP1 yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage MP a.a. 1412.4.2 Optimum Start Indicate optimum start controls a. a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans MP1.1 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas n. a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule MP1 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule MP1 a. a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb a. a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n. a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary MP 1 yes 1414.2 Duct insulation Indicate R -value of insulation on duct MEP 1 yes 1415.1 Piping insulation Indicate R -value of insulation on piping MP1 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan MP1 yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing MP1 yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training la yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report MP1 n. a. 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n. a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off n.a. 1443 Pipe Insulation Indicate R -value of insulation on piping CEI FF a. a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency NOV Z.:b Z007 n.a. 1453 Pool heater controls Indicate switch and 65 degree control PERMIT GENIE n.a. 1454 Pool covers Indicate vapor retardant cover n. a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: P ackaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a hum idistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing . transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 - 525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all trap� r joints arid. p'' longitudinal seams. K EGEI �.J 3. Static pressure: above 3 inches; seal all transverse joints, longitudina seams and duct wall penetrations. �� nn' Duct tape and other pressure sensitive tape shall not be a p� sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. PERMIT 1414.2 Insulation: Ducts and plenums that are constructed an u nlc ' uona5 (ia the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: P ackaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a hum idistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings 1412.8 Ventilation Controls for High Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing . transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 - 525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all trap� r joints arid. p'' longitudinal seams. K EGEI �.J 3. Static pressure: above 3 inches; seal all transverse joints, longitudina seams and duct wall penetrations. �� nn' Duct tape and other pressure sensitive tape shall not be a p� sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. PERMIT 1414.2 Insulation: Ducts and plenums that are constructed an u nlc ' uona5 (ia the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, ,, ,29,0ft b0g,t,p $10§,, ucq jApntiaLEnergy..Co.de Camplianre.F.nrin outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 - 6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) NOV 26 2007 PERMIT UEN i E. ACTIVITY NUMBER: M07 -253 DATE: 11 -26 -07 PROJECT NAME: MICHAELS SITE ADDRESS: 17400 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bui di g Division PERMIT COORD COPY' PLAN REVIEW /ROUTING SLIP �I2 ,4j, I Fire Prevention X Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Please Route Documents/routing slip.doc 2 -28 -02 TUES/THURS ROUTING: Incomplete Structural Review Required Planning Division DUE DATE: 11 -29-07 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 12 -27 -07 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PHOENMC937KT Licensee Name PHOENIX MECHANICAL CORPORATION Licensee Type CONSTRUCTION CONTRACTOR UBI 602725673 Ind. Ins. Account Id 13554400 Business Type CORPORATION Address 1 PO BOX 2033 Address 2 City MANCHACA County OUT OF STATE State TX Zip 786522033 Phone 5122910785 Status ACTIVE Specialty 1 AIR CONDITIONING Specialty 2 UNUSED Effective Date 5/30/2007 Expiration Date 5/30/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date MANGOLD, VICTOR PRESIDENT 05/30/2007 ROYALS, MIKE SECRETARY 05/30/2007 HUGHES, NEAL TREASURER 05/30/2007 BARNARD, DEAN VICE PRESIDENT 05/30/2007 ,......,� t.... .,,,.,�.....,� J-.,■•••.., NASA .., a ,b■,,,.,.., ar,vvaZ ? ✓v V.%k Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= PHOENMC937KT 02/26/2008 HVAC REQUIREMENTS OUTSIDE AIR CALCULATIONS RTU SCHEDULE [REFERENCE ONLYI HVAC DRAWING INDEX GENERAL REQUIREMENTS THE FOLLOWING PLANS AND SPEC /FlCAT/ONS INDICATE THE MINIMUM DESIGN CONDmONS ACCEPTABLE TO M /CHAELS STORES INC.. EVEN IF NOT INDICATED ON THE PLANS, THE CONTRACTOR SHALL COMPLY NTH ALL CODES AND ORDINANCES GOVERNING THE INSTALLATION OF HEATING AND AIR CONDITIONING SYSTEMS AND COMPONENTS. HVAC SYSTEMS AND COMPONENTS SHALL COMPLY V1717/ THE DESIGN PARAMETERS INDICATED IN 171E LATEST EDITION OF ASHRAE AND 5MACN4 STANDARDS. SCHEDULE OF WORK HVAC SYSTEM TO BE OPERATIONAL MINIMUM OF 2 WEEKS BEFORE COMPLETION. THE MECHANICAL CONTRACTOR SHALL PERFORM ALL HVAC EQU IPMENT INSTALLATIONS AND SHALL BE RESPONSIBLE FOR THER PROPER INSTALLATION AND OPERATION. PRIOR TO ANY WORK, THE MECHANICAL CONTRACTOR SHALL VERIFY ALL SIRUCTUR 4 ARCHITECTURAL, OR ELECTRICAL COMPONENTS THAT MIGHT CONFLICT WITH THE HVAC EQUIPMENT INSTALLATION. IF OF RECORD THE MECHANICAL CLARIF�ON /O S THE ELECTRICAL CONTRACTOR SHALL MAKE ALL f7/ 4L ELECTRICAL CONNECTIONS TO THE HVAC EQUIPMENT: 171E MECHANICAL CONTRACTOR SHALL PROVIDE INSTALLATION AND OPERATIONAL CUT SHEETS FOR THE ELECTRICAL CONTRACTOR. EQUIPMENT OPERATIONAL CHECK AFTER THE HVAC SUBCONTRACTOR COMPLETES THE HVAC INSTALLATION AND STARTUP, AS PER THE MANUFACTURER'S INSTRUCTIONS, THE CONTRACTOR SHALL INSPECT EQUIPMENT AND ITS OPERATION. 171E EQUIPMENT OPERATIONAL CHECK (EOC) WILL AID THE CONTRACTOR IN MAKING FT AD US1MlENTS CHECKING S NECESSARY FOR PROPER OPET2A110N AND THE HVAC SUBCONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDUUNG THE EOC WITH THE MANUFACTURER AT LEAST THREE WEEKS PRIOR TO DESIRED COMPLETION DATE THE FOLLOWING PARTIES MUST BE PRESENT FOR THE DURATION OF THE EOC: - ENAC SUBCONTRACTORS QUAUFlED MECHANIC - SERVICING CONTRACTORS QUALIFIED MECHANIC OF DIFFERENT HVAC SUB) ALL TEST EQUIPMENT 70 BE MADE AVAILABLE BY THE SERVICING CONTRACTOR AND MECHANICAL SUBCONTRACTOR. IF AMB/E7VT CONDITIONS D0 NOT PERMIT PROPER AN CONDITIONING OPERATIONAL CHECK, AN ADDfOM4L COOLING EOC MUST BE SCHEDULED WITH ABOVE PARTIES PRESENT. HVAC SUBCONTRACTOR SHALL PROVIDE THE ARCHITECT WITH THREE (3) COPIES OF EOC REPORTS PRIOR TO F7NAL PAYMENT. (Based on 2006 Washington State Ventilation and Indoor Air Quality Code) Outside Air Required A. Building Area MARK MANUF. CATALOG TONS CFM VOLT/ PHASE HEAT ECONOMIZER __ _ ..` \ TRANE YFD075C4HGBE 6.25 2600 460/3 GAS ENTHALPY DZC1 VAV DTS1 p I ' . 1 . IRTU 11 TRANE YFD150C4HGBE 12.5 5000 460/3 GAS ENTHALPY - (RTU 2 J REMOTE AIR VAV DUCT IN -LINE DUCT UNIT HEATER DUCT MOUNTED SIDEWALL"' . LIST TEMP SENSOR DAMPER AIR AIR TEMP SENSOR AIR TEMP SENSOR SMOKE DETECTOR SUPPLY AIR Sales Areas: 19,100 S F. Bulk Stock and Storage: 5,595 S.F. q Office Areas: Corridors: 270 S.F. Toilet Rooms: 330 S.F. TRANE YFD150C4HGBE 12.5 5000 460 3 / GAS ENTHALPY I RTU 3 J (DIGITAL ZONE TEMP SENSOR DIFFUSER EX STEP DOWN FAN CONCENTRIC CONTROLLER) DIFFUSER TRANE YFD150C4HGBE 12.5 5000 460/3 GAS ENTHALPY INLINE DAMPER I RTU 41 % j A SDI DESIGNATION CO2 ® BoTroM - DUCT ABOVE TRANE YFD150C4HGBE 12 5000 460/3 GAS ENTHALPY I RTU 5 1 I EF - 1 CFM DUCT ;II EQUIPMENT AIR INLET OR CARBON DIOXIDE RETURN AIR IN-LINE Total Floor Area (Net): 26, 770 ,5 F B. Occupant Loading: TRANE YFD120B4HGBE 10 4000 460/3 GAS ENTHALPY RTU 61 S UPPLY AIR FLOW DAMPER EXHAUST SYMBOL SUPPLY OUTLET (CO2) SENSOR EXHAUST DIFFUSER An FAN TRANE YFD120B4HGBE 10 4000 460/3 GAS ENTHALPY IRTU 71 D U T CONSTRUCTION Office Areas 8 Occupants /1000 S.F. = 12 Occupant(s) Sales Areas 8 Occupants /1000 S.F. = 153 Occupant(s) C. Outside Air Required: TRANE YFDO75C4HGBE 6.25 2600 4603 / GAS ENTHALPY I RTU 81 LOW PRESSURE (MAXIMUM .2" W.C.) PER SMACNA "DUCT CONSTRUCTION" CLASSIFICATION WHERE LOCAL MUNICIPAL ENERGY CODES REQUIRE MORE DUCT INSULATION - DUCTWORK AND PLENUMS - OR CONSTRUCT OF THE FOLLOWING GAUGES: THE CONTRACTOR SHALL COMPLY WITH THOSE REQUIREMENTS. DUCT AT WIDEST DIMENSION U.S. GAUGE GALVANIZED STEEL UP THRU 12" 24 GAUGE FLEXIBLE DUCT SECTIONS SHALL NOT EXCEED 6' --O ". IN OVERALL 13" THRU 30" 22 GAUGE DEVELOPED LENGTH. 31" THRU 54" 20 GAUGE PROVIDE MANUAL VOLUME DAMPER AT ALL TAKEOFFS LOW PRESSURE SHEET METAL FABRICATION AND INSTALLATION SHALL BE AS FOLLOWS: (INTEGRAL W /SPIN -IN FITTINGS) AS ILLUSTRATED BELOW. ALL DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH STANDARDS SET FORTH IN THE LATEST EDITION OF THE ASHRAE GUIDE AND SMACNA PROVIDE TURNING VEINS AND SPUTTER DEVICES AS ILLUSTRATED BELOW. HVAC SYSTEMS DUCT DESIGN UNLESS MODIFIED HEREIN. EXTRACTORS OR AIR SCOOPS ARE REQUIRED AT EACH SPLIT IN THE DUCT AS ILLUSTRATED BELOW. DUCT SIZES SHOWN ON PLANS ARE ACTUAL SHEET METAL INSIDE DIMENSIONS. TRANSITION ANGLES SHALL NOT EXCEED 15 DEGREES ALL CONCEALED DUCT WORK SHALL BE GALVANIZED STEEL WITH AS ILLUSTRATED BELOW. 1 1/2" THICK FIBERGLASS INSULATION BLANKET WITH FOIL BARRIER. ALL EXPOSED DUCT WORK SHALL BE INTERNALLY LINED WITH 1" LINER. PROVIDE MINIMUM DUCT TURNING RADIUS AS ILLUSTRATED BELOW. ALL SPIRAL DUCT WORK SHALL BE INTERNALLY UNED WITH 1" LINER AT THE FIRST 1C-0. THE FOLLOWING ITEMS ARE FIELD INSTALLED ONLY EACH R.T.U. SHALL BE CONTROLLED VIA DIGITAL ZONE CONTROLLER (DZC) LOCATED IN THE OFFICE PER MECHANICAL PLAN. NOTES ALL EQUIPMENT IS EXISTING TO REMAIN. CONTRACTOR SHALL SERVICE RTU'S TO VERIFY PROPER OPERATION CONDITION. SEE HVAC REQUIREMENTS THIS SHEET FOR ADDITIONAL INFORMATION. Sales Areas: 153 Occupant(s) x 15 CFM /Occupant = 2,292 CFM Stock Areas: 5,595 S.F. x 0.15 CFM /S.F. = 839 CFM Office Areas: 12 Occupant(s) x 20 CFM Occup ant = 236 CFM Corridors: () 270 S.F. X 0.05 CFM /S F. = 14 CFM Total Outside Air CFM Required = 3,381 CFM D. Outside Air Provided: SINGLE LINE DOUBLE FITTING SINGLE UNE DOUBLE FITTING RTU -1 = 300 CFM RTU -2 = 500 CFM RTU- -3 = 500 CFM RTU -4 = 500 CFM RTU -5 = 500 CFM RTU- -6 = 400 CFM = 400 CFM RTU-8 = 300 CFM Total O.A. , 400 CFM Provided = 3 LINE LINE ACOUSTICALLY AN CONDITIONING UNITS SHALL BE BALANCED AND IES/EU BY NEBB CERTIFIED CONTRACTOR. B41ANCE AND TEST REPORT MUST BE SUBMITTED TO 171E DESIGN PROFESSIONAL FOR APPROVAL APPROVED TEST AND BALANCE REPORTS MUST BE PRESENTED TO MlCHAELS AS PART OF THE ACCEPTANCE OF SPACE PROVIDE A SET OF OPERATION AND MAINTETVANCE MANUALS FOR ALL HVAC EQUIP. TO STORE MANAGE? AND M/CHAELS CONSTRUCTION DEPARTMENT: HVAC EQUIPMENT CONTRACTOR SHALL HELD VERIFY THAT THE EXISTING EQUIPMENT INCLUDING ACCESSORIES IS NOT DAMAGED AND 1S IN GOOD WORKING RDER REPORT ANY DET7C/ENC /ES TO THE OWNER OR ARCHITECT. CONTRACTOR SHALL SUBMIT TO THE OWNER AND ARCHITECT A WRITTEN REPORT DESCRIBING RESTS PERFORMED TO VERIFY OPERATION AND RESULTS OF THE TESTS CLEAN EXISTING EQU /PME7VT AND EQU IPMENT COMPONENTS TO REMAIN. PROVIDE NEW FOR EXISTING AIR HANDLING EQU /PMENT PRIOR TO STARTUP OF EQU /PMEM: NEW FlL7ERS SHALL BE COMPATIBLE WTIH THE EXISTING EQUIPMENT AND EQUAL IN PERFORMANCE TO THE EXISTING FlLTERS AT NEW CONDITION UNLESS OTHER7SE NOTED. LUBRICATE EXISTING EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS WR117E1V INSTRUCTIONS. FULLY CHARGE EX/ST7NG REFRIGERATION SYSTEMS TO REMAIN W1171 NEW REFRIGERANT MATCHING EXISTING SYSIEMl. INDOOR A/R QUALITY MEASURES: PROTECT INSIDE OF (INSTALLED AND DEUVENED) DUCTWORK AND HVAC UNITS FROM EXPOSURE TO DUST, DIRT, PAINT AND MOISTURE. REPLACE INSULATION THAT HAS GOTTEN WET AT ANY TIME DURING CONSTRUCTION, DRYING THE INSULATION IS NOT ACCEPTABLE SEAL ANY TEARS OR JOINTS OF INTERNAL FIBERGLASS INSULATION REMOVE DEBRIS FROM CEIUNG/RETURN AIR PLENUM INCLUDING DUST. AN lNDEPENDLM, PROFESSIONAL DUCT CLEANING COMPANY SHALL VACUUM CLEAN ANY DUCTWORK CONNECTED TO HVAC UNITS THAT WEREOPLR4TED DURING THE CONSIRUCTIONPERIOD AFTER NEW flL7 ARE INSTALLED AND PRIOR TO TURNING SYSTEM OVER TO THE OWNER THERMOSTATS THERMOSTATS PROVIDED BY SITE CONTROL, INC. (LABELED DZC - D/G/TAL ZONE CONTROLLER) MECHANICAL CONTRACTOR SHALL PROVIDE HIRING DIAGRAMS 70 ELECTRICAL CONTRACTOR. WRING BETWEEN THERNSTAIS, SENSORS, AND RTUs SHALL BE COMPLETED BY THE ELECTRICAL CONTRACTOR. PROVIDE THERMOSTAT WITH A MIN /MUM SF DEAD&WD, NIGHT SETBACK, AND 7 LAY PROGRAMMABLE' CABABILITY DUCT WORK INSTALLATION ALL DUCT WORK SHAG BE INSTALLED BY A QUALIFlED HVAC CONTRACTOR. NO PROTRUSIONS BELOW 19'-0' AT SALES AREA ALL MAIN TRUNK AND BRANCH DUCTS SHALL RUN PERPENDICULAR OR PARALLEL TO THE STRUCTURE DUCT WORK IN THE SALES AREA SHALL BE NEAT IN APPEARANCE. ALL DUCT WORK SHALL BE CLEANED PRIOR TO TENANT OCCUPANCY PROVIDE ACCESS PANELS FOR ALL CONCEALED SMOKE DETECTORS AND DEVICES IN DUCT WORK OR MECHANICAL CHASES ALL DUCTOWRK SHALL BE SEALED, INSULATED, AND INSTALLED PER SMACMA AND CHAPTER 14 OF 171E 2006 WASHINGTON STATE NON RESIDEN17AL ENERGY CODE BUILDING CONTROL SYSTEM BUILDING ALL BUILDING CONTROLS SHALL BE BY SITE CONTROLS INC. COORDINATE REQUIREMENTS WITH R/TA TREVINO AT 877.306.9400. CONTRACTOR SHALL PROVIDE A COMPLETE BUILDING CONTROL SYSTEM INCLUDING ALL LABOR, MATERIALS AND INSTALLATION. PROVIDE A NEW DIGITAL ZONE CONTROLLER DZC AND DUCT TEMPERATURE SENSOR DRS AT EACH EXISTING " ROOF TOP UNIT PROVIDE AN INTERFACE AS REQUIRED BOWE& THE EXISTING TRANE RTU CONTROL PANEL AND 771E DZC AND A SINGLE CO2 SENSOR MOUNTED IN 171E SPACE. SEE EMS SINGLE UNE DRAWINGS FOR ADDITIONAL INFORMATION. COMMISSIONING REQUIREMENTS PROJECT COMM1S IONINGREQUIRIBISSHALL CONFORM TOCI R 14OF THE 2006 WASHINGTON STATE NON RES/DEMTAL ENERGY CODE THESE REQUIREMENS SHALL INCLUDE; BUT ARE NOT LIMITED TO A PRELIM /NARY COMMISSIONING REPORT M/VAL COMMISSIONING REPORT AND ACCEPTANCE DOCUME7VTS IN ADD/17ON, PROVIDE SYSTEM OPERATIONAL TRAINING, O&M MANUALS AND RECORD DRAWINGS TO THE OWENER PER 2006 WASHINGTON STATE NON- RES /DEIVTIAL ENERGY CODE LINED DUCT t LI RECTANGULAR DUCT RISER CONICAL TEE TEE (SIZES SHOWN ARE NET INSIDE) CONNECTION ROUND ® t DUCT RISER 7 t RECTANGULAR DUCT DROP X 1 90' RECTANGULAR ELBOW WITH U NIT H EATER S CHEDULE I I �, 0 ROUND i � t ® ) DUCT DROP TURNING VANES RECTANGULAR R =w MARK MAN U F. CATALOG KW H CFM UNIT PHASE MCA NOTES t ~ BERKO HUHAA2548 25 2100 125 480/3 30 ALL NOTES BELOW t OFFSET LESS THAN 15' i RADIUS ELBOW 0 1 UH -1 I I � t RECTANGULAR 1. UNIT HEATER SHALL BE INSTALLED PER THE MANUFACTURERS 3. PROVIDE UNIT HEATER THERMOSTAT MOUNTED IN THE LOADING AREA SPECIFICATIONS AND CODE REQUIREMENTS WHETHER OR NOT AT 60" AFF. PROVIDE THERMOSTAT MOUNTING BRACKET. INDICATED ON THE PLANS. 4. PROVIDE FACTORY MOUNTED DISCONNECT. 2. UNIT HEATER SHALL BE SUSPENDED FROM THE TOP CHORD OF THE PRIMARY BUILDING STRUCTURE. REFER TO DETAIL- 3/MP1.2 \ OFFSET MORE I THAN 15' RECTANGULAR DUCT ROUND t t RECTANGULAR ,` � WYE 1 • BRANCH NCH MAIN WITH AIR ROUND BRANCH SCOOP SPIN --IN FITTING AIR DISTRIBUTION DEVICE SCHEDULE MARK NECK FACE TYPE DEFLECTION DAMPER MANUF. CATALOG CONST. FINISH MOUNT NOMINAL CFM RANGE REMARKS - EXTRACTOR r D< STEP DOWN SUPPLY 4 -WAY - -- TIES ADB -1 STEEL BRIGHT WHITE UNISTRUT 2600 MOUNT WITH LOUVERS JUST BELOW STRUCTURE. RECTANGULAR MAIN WITH l sDr t t 45"0 RECTANGULAR BRANCH 19"x19" 12 "x12" SUPPLY 4 -WAY OPP.BLADE TITUS -AG75 TITUS (OR EQUAL) TMS -AA ALUMINUM WHITE GRID CEILING 100 -125 ® 6 DIA t t t > ? ID CONCENTRIC 12 "x12" SUPPLY 4 - WAY OPP.BLADE TITUS -AG75 TITUS (OR EQUAL) TMS -AA ALUMINUM WHITE GRID CEILING 200 -250 ® x �. 1 BELLMOUTH SQUARE TO 15. MAX ROUND 8 DIA OPP.BLADE TITUS -AG75 TITUS (OR EQUAL) TMS -AA ALUMINUM WHITE GRID CEILING 350 -450 M4M ® ROUNND __J---+ (RECTANGULAR L.... t 24 " SUPPLY 4- WAY OPP.BLADE TITUS -AG75 TITUS (OR EQUAL) TMS_AA ALUMINUM WHITE GRID CEILING 500 -700 ROUND MAIN 15 ' M OR ROUND) S4 12" DIA , DUCT WITH CONICAL TEE IT ROUND BRANCH 3a• TRANSITION Y NON SYMMETRICAL WYE 11 -1 /2 "x 7 _ 1 / 2 ,, SUPPLY 2 -WAY OPP.BLADE TITUS -AG95 TITUS OR EQUAL) 300 -RS ALUMINUM WHITE SIDE WALL 100-550 ® ® 12"x8" ROUND t — " 13 - 1 /2 1 1 -1 /2 RETURN 0' FIXED - -- TITUS (OR EQUAL) 50F ALUMINUM WHITE SIDE WALL 200 -850 MOUNT IN WALL AT 16' -0" AFF MIN. - �l BRANCH w DOUBLE FORMED TURNING VANES 15' MAX CONCENTRIC R1 1 ® 14 15 - 1 /2 15-1/2" RETURN 0 FIXED 1 /2" CORE ___ TITUS (OR EQUAL) 50F ALUMINUM WHITE SIDE WALL 400 -1600 MOUNT IN WALL AT 16 - O AFF MIN. R2 " " ® 16"x16" 3 W B - 2 z p 23-1/2" 23 -1 /2 RETURN/ TRANSFER 0 FIXED 1 /2 CORE ___ TITUS (OR EQUAL) 50F ALUMINUM WHITE GRID CEILING 400 -3200 TRANSMON R4 Q SYMMETRICAL t 1 a - - - -� PER PLAN DOUBLE FORMED TURNING VANES S .. w • ' , 25 " x25 �� RETURN 0 FIXE 1 /2" CORE ........__ TITUS (OR EQUAL) 50F ALUMINUM WHITE SIDE WALL 400 -3200 MOUNT IN WALL AT 16 > -0 » AFF MIN R5 " ® 24 x24 - -- VARIABLE AIR _ OPP.BLADE MOTORIZED LENNOX (NO EQUALS) 355 -FL ALUMINUM - -- IN -LINE 800 -1200 REFER TO MOTORIZED DAMPER DETAIL-1/MP-1.2 D1 ® 14 DIA PLUMBING FIXTURE SCHEDULE p . PLUMBING REQUIREMENTS F 4 _ w y -: r MARK DESCRIPTION MANUF CATALOG NUMBER FINISH MOUNT VALVE TYPE WATER CONSUMP. STANDARD TEST DETAIL WASTE VENT CW HW REMARKS GENERAL REQUIREMENTS HANGERS AND SUPPORTS THE SANITARY SEWER SYSTEM SHALL COMPLY WITH ALL CODES AND 1. PIPE HANGERS SHALL BE MANUFACTURED BY TYLER, MILWAUKEE, OR MUNICIPALITY REQUIREMENTS WHETHER OR NOT PROVIDED IN THE DRAWINGS. EQUAL AND SHALL BE INSTALLED AT ALL BENDS, ANGLES AND ENDS OF ALL PLUMBING MATERIAL SPECIFICATIONS: WASTE AND SEWER LINES AS CALLED FOR ON THE DRAWINGS AND LOCAL CODES. ALL CLEANOUTS SHALL BE BROUGHT TO GRADE, AND IN ALL CASES, SANITARY SEWER PVC, CAST IRON OR COPPER SHALL BE PROVIDED WITH SUFFICIENT SPACE FOR RODDING. PIPING MAY BE USED EXCEPT THAT ALL PIPING BELOW GRADE SHALL BE CAST IRON (OR PVC IF ALLOWED BY LOCAL CODES.) VENTS (2 ") INCHES IN SIZE AND SMALLER MAY BE EITHER SCHEDULE 40 GALVANIZED STEEL OR COPPER PIPING. 0 LAVATORY ETR ETR ETR ETR HW /CW FAUCET 2.5 GPM ANSI A117.1 A112.19.2M -- -- _� " 1/2" 1 /2 " USE MANUFACTURER SEE NOTES 1, 2, 3 LISTED DEVICE ONLY 0 KITCHEN SINK ETR ETR ETR ETR HW /CW FAUCET 2.0 GPM ANSI A117.1 A112 19 2M __ __ __ 1/2 " 1/2 " USE MANUFACTURER SEE NOTES 1, 3 LISTED DEVICE ONLY 1. INSTALL AMERICAN STANDARD FAUCET #7500.170. 2. INSULATE HOT AND COLD WATER VALVES UNDER 3. PROVIDE OFFSET WHEELCHAIR P -TRAP WITH ALL SINKS SHALL HAVE LEVER TYPE CONTROLS. LAVATORIES. INSULATED PROTECTIVE KNEE COVER. FILE COPY SEPARATE PERMIT REQUIRED FOR: lee Permit No. D M ,rr� Electrical Plan revleo ppror181 ISSN tQ �' Plumbing Approval of CpnStNCtion �e [ J ' G as Piping �, LLedcodeor�. t the violation of any a .. City of Tukwila o1 approved r ` ' ". �� 'w a Dl Date: :Bl1�L CrQ #TV „ DOMESTIC WATER AND HOT WATER PIPING SHALL BE COPPER TYPE 1 UNION "L" WITH WROUGHT COPPER FITTINGS. HOSE BIBB ALL HOT AND COLD WATER LINES SHALL BE INSULATED WITH ARMAFLEX WATER METER W BACKFLOW ". OR EQUIVALENT INSULATING TO A THICKNESS OF 1 PREVENTER GATE VALVE ALL PIPING SHALL BE INSULATED, AND INSTALLED PER CHAPTER 14 _ O CD CLEAN -OUT O F THE 2006 WASHINGTON STATE NON- RESIDENTIAL ENERGY CODE. DOMESTIC COLD WATER - --- DOMESTIC HOT WATER V.T.R. VENT THRU ROOF MAKING UP PIPE VENT LINE -- -- SCREWED PIPE SHALL BE MADE WITH PIPE COMPOUND APPLIED TO A.F.F. ABOVE FINISH FLOOR THE MALE THREAD WITH NOT MORE THAN TWO THREADS LEFT EXPOSED. -� SANITARY LINE PIPE SHALL BE REAMED AFTER THREADING. B.F.F. j „, BELOW FINISH FLOOR 0 GAS LINE BELOW GRADE SANITARY PIPE SHALL BE CAST IRON AND SHALL F.F.D. FUNNEL FLOOR DRAIN BE MADE UP WITH ONE THIRD OF THE HUB CAULKED WITH FIRST QUALITY OAKUM, AND THE REMAINDER FILLED WITH FIRST QUALITY F.D. :0, FLOOR DRAIN CAULKING AT ONE POURING AND CAULKED TIGHT. COPPER JOINTS SHALL BE MADE UP WITH 95 SOLDER. RECEIVED NOV 2 6 2007 M 0 147.... 2 5 3 PERMIT CENTEI:, 8�1 ®� DIVISION • - r�all � ': £SIt rna �N5 No changes s'�rde o te scn � �be ; of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal -nd may include additional plan review fees LL EXP. 11 /07/98 0 r 0 0 r 0 w 1- 0 T 1 � rt DRAWING CONTENTS: MECHANICAL SCHEDULES DRAWING NO.: MP1 5 NOTE: STANDARD ROUND DUCT AS SCHEDULED IN —LINE MOTORIZED DAMPER SECTION ROOM THERMOSTAT TO BE LOCATED PER MECHANICAL PLAN MOTORIZED DAMPER SCALE: N.T.S. DAMPER MOTOR STANDARD ROUND DUCT AS SCHEDULED DUCT SENSOR SUPPLIED W/ DAMPER SECT. (DOWN STREAM) 1 375 S5 ( 400 SS. / ' \t t 55 400 LOW VOLTAGE WIRING FROM SENSOR TO REMOTE THERMOSTAT 55 325 1 UH -1 STAGING TYP 7 1 105 1 TYP4 REFER TO 3 /MP1.1 FOR MOUM7NG DETAIL 24 VOLT POWER SUPPLY TO MOTORIZED DAMPER SECTION FROM THERMOSTAT • • • • ti DZC9 120 VOLT TO 24 VOLT TRANSFORMER INSTALL ABOVE CEILING 12' -6" A.F.F. Ir� DZCB 18' D14 inininCan -- 18 DM R5 INSTALL ' RN GRILLE AS /jIGH AS POSSIBLE IN IWALL 1 107 I saes WCMNE ( S3 300 7w 4 1 105 1 STAGING J / S3 \ \ 200 1 lox FLORAL R4 MEE!TNG ROOM 1 102 1 ICI ly1 : /I\ 3/8 "-16 NUT 3/8" LOCK WASHER UNIT HEATER MOUNTING FLANGE BOTTOM OF UNIT 12' - -6" AFF 0 SCALE: N.T.S. 20 DL4 L 20' DIA J 1 1 L J 24' DI A 22' DM UNIT HEATER SUPPORT 10 TON R111 E11 REBALANCE UNIT TO 4000 CFM SA, 400 CFM LTA. TIOr 10 TON RTU ETR. REBALANCE UNIT TO 4000 CFM SA, 400 CFM OA 1RTU -7 _1 ROOFTOP CONDENS14'G I- - UNIT TO BE REMO 1 - -1 AHU TO BE 1 I REMOVED I 1 L -1 777 6.25 TON RTU E772 REBALANCE UNIT TO 2600 CFM SA. 300 CFM OA 1 RTU -8 1 -1 /4"x1 —1 /4"x1 /4" 1-1/4" 1 -1 /4"x1 /4" 3/8" -16 NUT 3/8" LOCK WASHER 3/8"-16 NUT 3/8"-16 ROD 3/8" FLAT WASHER 3/8 " -16 NUT F 1 L1 z ijor ® I% a F .111_1 400 ROD 1 ► / - r : T i ' s SIZED TO 7)1 40, MATCH DUSTING R4 PLENUM AND TO EXTEND 4'. BOOT TO HAVE 24x24 R4 OPENING IN TOP. ■0' T L 1 _ . L ._1...11 1 LL DROP BOX DIFFU DZC4 RETURN A/R BOOT C FLOOR PLAN HVAC SCALE: 1 /8 = 1 —0 DROP BOX DIFFUS Lite •OL ..1 1► I NM II MONITOR ONLY *co DZC5 RETURN A/R BOOT E7R — L NOTE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECTS OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES' BEFORE BEGINNING OR FABRICATING ANY WORK. NOTE: G.C. TO VERIFY LOCATION OF POWER POLES BEFORE INSTALATION OF THE DUCT WORK TO PREVENT ANY CONFLICT IN PLACEMENT OF FUTURES. MECHANICAL CONTRACTOR SHALL COORDINATE WITH ET.ECTRIC4L CONTRACTOR THE REQUIRED VOLTAGE OF THE ROOF TOP UNITS PRIOR TV ORDERING SYSTBIS CUT SHEETS 5ILALL BE SUBMITTED TO MICHAELS' AUTHORIZED REPRESENTATIVE FOR APPROVAL PRIOR TO ORDERING. NOTE EXLS7TNG CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT' CONDITIONS. FIELD VERIFY ALL EX1S71NG CONDITIONS PRIOR TO SUBMITTING FINAL BIDS CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 12.5 TON RTU E7R. REBALANCE UNIT TO 5000 FM OA Li 1 REBALANCE UNIT TO 5000 CFM SA, 500 CF' OA 1 L I L I L 1 111 SOLES O 00 TAP SIDE OF DUCT ABOVE CONCENTRIC SUPPLY /RETURN GRILL WITH THE TOP OF THE BRANCH DUCT TIGHT TO JOISTS PROVIDE AES STEP DOWN CETUNG DIFFUSER BOTTOM OF DIFFUSER FACE TO BE MOUNTED AT SAME HEGHT AS EXISTING DIFFUSERS. INSTALL DTS PROBE IN SUPPLY AIR PLENUM OR INTEGRAL DIFFUSER. 1 1 DR. 1 NIT TO CFM ' 1 SD 1 — ■ """■ _ 1 1 12600 IIMI1 11 t ''Q i 1 1 il I h PROVIDE N RE7UR • R BOOT SIZED CH LX/ h ; 1 PLENU DTOEXTERD4 BOOT TO HA 4 RA OP: IN IN TOP. � C DZC1 DZC2 MVP BUX L&f•%UStie tire O 00 00 0 0 cb T F � r .: PAINT ALL EXPOSED DUCTWORK TO MATCH THE SURROUNDING CEILING. REFER TO FINISH SCHEDULE ON ARCHITECTURAL SHEETS. s i m TT ........ ..,......■ 24 TON RTU Ell CE UNIT 7V -5000- CFM 54, 500 CFM OA I RTU - 31 DIGITAL ZONE CONTROLLERS SHALL BE MOUNTED ON THE BACK SIDE OF THE COLUMN AT 108' AFT. CIRCUIT LOCATION PER MANUFACTURERS SPECIFICATIONS. AT 72' AFF WHERE LOCATED IN OFFICE FOR UNIT NO. 2. SUPPLY AND RETURN GRILL FACES AND TRIM COLOR SHALL MATCH CEUNG. PROVIDE 'CONICAL SPIN IN' FITTINCS WITH INTEGRAL VOLUME DAMPERS AT EACH TAP. ALL SIDE WALL SUPPLY DIFFUSER BLADES ARE TO BE TURNED DOWN 15 DEGREES. REMOVE ALL EXISTING DIFFUSERS, GRILLES AND DUCTWORK ASSOCIATED WITH RTU BACK TO SUPPLY AND RETURN DROPS. SEAL OPENINGS NOT BENG REUSED. PATCH WALLS AND CEILINGS TO MATCH EXISTING. REFER ARCHITECTURAL ROOF MOUNTED DOWNBLAST EXHAUST FAN, DUCTWORK AND GRILLES ARE ETR. CLEAN GRILLES AND VERIFY THAT FAN IS NOT DAMAGED AND IN GOOD WORKING ORDER. REPORT ANY DEFICIENCIES' TO THE ARCHITECT OR OWNER MOUNT CO2 SENSOR AT 76" AFT. SENSOR SHALL BE FOR MONITORING ONLY. CONNECT TO BUILDING CONTROL SYSTEM. LOCATION OF LENNOX MOTORIZED ZONE DAMPER. COMPLETE WITH ?4 , TRANSFORMER LOCATE TRANSFORMER ABOVE OFFICE CEILING AT 12 —0 AFT. 12.5 TON 1?T71 E7R. REBALANCE UNIT TO 5000 CFM SA, 500 CFM OA. 20 0A TRANS AS HIGH AS POSSIBLE IN WALL , 1 1 1 _ .F S [ 1 THERMOSTAT MOUNTED AT 72' AFT. INSTALL TRANSFER GRILLE AS HIGH AS POSSIBLE IN WALL 0 .0n o ( D1 REFER TO 2 /MP1.1 DUCT SMOKE DETECTOR INSTALLED IN SUPPLY /RETURN OR AS REQU /RED BY THE FIRE MARSHALL HAVING JURISDICTION. PROVIDE ACCESS PANEL 1' INTERNAL LINER IN THE FIRST 10' -0' OF THE SPIRAL DUCT. BOTTOM OF STAGING AREA RIGID DUCT AT 14' -0" AFT. ALL EXPOSED DUCTWORK IN SALES AREA SHALL BE SPIRAL DUCTS. NO EXCEPTIONS OR ALT LOW VOLTAGE CONTROL WIRING FOR MOTOR /ZED ZONE DAMPER. WRING TO BE HIDDEN FROM VIEW. ROUTE WRING DIRECTLY ABOVE SUPPLY DUCT. Fl EX/BLE PORTIONS OF DUCT ARE NOT TO EXCEED 6=0' IN OVERALL LENGTH. CUT AND PATCH EXISTING CEILING AS REQUIRED FOR THE INSTALLATION OF NEW DUCTWORK AND A/R DEVICES. PATCH OPENINGS TO MATCH EX /5TMNG. REFER TO ARCHITECTURAL REQUIREMENTS COORDINATE NEW DUCTWORK WITH EXISTING CONDITIONS REROUTE DUCTWORK AS REQUIRED. REMOVE EX/ST/NG SUSPENDED AHU AND CONDENSING UNIT ON ROOF. REMOVE ALL DIFFUSERS, GRILLES', DUCTWORK AND PIPING ASSOCIATED WITH AHU BENG REMOVED. SEAL OPENINGS NOT BENG REUSED. PATCH ROOF, WALLS AND CE7UNGS TV MATCH DUSTING. REFER ARCHITECTURAL RECEIVE-? CLEAN, REPAINT AND REBALANCE EXISTING DROP BOX DIFFUSER AS NOV 2 6 20( 7 REQUIRED. PERMIT CEN" •E w 1- 0 j - r fi LJ l LL 0 0 r to 0 0 0 0 DRAWING CONTENTS: MECHANICAL PLANS DRAWING NO.: MP1.1 I1 T 1 5 NOTE: STANDARD ROUND DUCT AS SCHEDULED IN —LINE MOTORIZED DAMPER SECTION ROOM THERMOSTAT TO BE LOCATED PER MECHANICAL PLAN MOTORIZED DAMPER SCALE: N.T.S. DAMPER MOTOR STANDARD ROUND DUCT AS SCHEDULED DUCT SENSOR SUPPLIED W/ DAMPER SECT. (DOWN STREAM) 1 375 S5 ( 400 SS. / ' \t t 55 400 LOW VOLTAGE WIRING FROM SENSOR TO REMOTE THERMOSTAT 55 325 1 UH -1 STAGING TYP 7 1 105 1 TYP4 REFER TO 3 /MP1.1 FOR MOUM7NG DETAIL 24 VOLT POWER SUPPLY TO MOTORIZED DAMPER SECTION FROM THERMOSTAT • • • • ti DZC9 120 VOLT TO 24 VOLT TRANSFORMER INSTALL ABOVE CEILING 12' -6" A.F.F. Ir� DZCB 18' D14 inininCan -- 18 DM R5 INSTALL ' RN GRILLE AS /jIGH AS POSSIBLE IN IWALL 1 107 I saes WCMNE ( S3 300 7w 4 1 105 1 STAGING J / S3 \ \ 200 1 lox FLORAL R4 MEE!TNG ROOM 1 102 1 ICI ly1 : /I\ 3/8 "-16 NUT 3/8" LOCK WASHER UNIT HEATER MOUNTING FLANGE BOTTOM OF UNIT 12' - -6" AFF 0 SCALE: N.T.S. 20 DL4 L 20' DIA J 1 1 L J 24' DI A 22' DM UNIT HEATER SUPPORT 10 TON R111 E11 REBALANCE UNIT TO 4000 CFM SA, 400 CFM LTA. TIOr 10 TON RTU ETR. REBALANCE UNIT TO 4000 CFM SA, 400 CFM OA 1RTU -7 _1 ROOFTOP CONDENS14'G I- - UNIT TO BE REMO 1 - -1 AHU TO BE 1 I REMOVED I 1 L -1 777 6.25 TON RTU E772 REBALANCE UNIT TO 2600 CFM SA. 300 CFM OA 1 RTU -8 1 -1 /4"x1 —1 /4"x1 /4" 1-1/4" 1 -1 /4"x1 /4" 3/8" -16 NUT 3/8" LOCK WASHER 3/8"-16 NUT 3/8"-16 ROD 3/8" FLAT WASHER 3/8 " -16 NUT F 1 L1 z ijor ® I% a F .111_1 400 ROD 1 ► / - r : T i ' s SIZED TO 7)1 40, MATCH DUSTING R4 PLENUM AND TO EXTEND 4'. BOOT TO HAVE 24x24 R4 OPENING IN TOP. ■0' T L 1 _ . L ._1...11 1 LL DROP BOX DIFFU DZC4 RETURN A/R BOOT C FLOOR PLAN HVAC SCALE: 1 /8 = 1 —0 DROP BOX DIFFUS Lite •OL ..1 1► I NM II MONITOR ONLY *co DZC5 RETURN A/R BOOT E7R — L NOTE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECTS OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES' BEFORE BEGINNING OR FABRICATING ANY WORK. NOTE: G.C. TO VERIFY LOCATION OF POWER POLES BEFORE INSTALATION OF THE DUCT WORK TO PREVENT ANY CONFLICT IN PLACEMENT OF FUTURES. MECHANICAL CONTRACTOR SHALL COORDINATE WITH ET.ECTRIC4L CONTRACTOR THE REQUIRED VOLTAGE OF THE ROOF TOP UNITS PRIOR TV ORDERING SYSTBIS CUT SHEETS 5ILALL BE SUBMITTED TO MICHAELS' AUTHORIZED REPRESENTATIVE FOR APPROVAL PRIOR TO ORDERING. NOTE EXLS7TNG CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT' CONDITIONS. FIELD VERIFY ALL EX1S71NG CONDITIONS PRIOR TO SUBMITTING FINAL BIDS CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 12.5 TON RTU E7R. REBALANCE UNIT TO 5000 FM OA Li 1 REBALANCE UNIT TO 5000 CFM SA, 500 CF' OA 1 L I L I L 1 111 SOLES O 00 TAP SIDE OF DUCT ABOVE CONCENTRIC SUPPLY /RETURN GRILL WITH THE TOP OF THE BRANCH DUCT TIGHT TO JOISTS PROVIDE AES STEP DOWN CETUNG DIFFUSER BOTTOM OF DIFFUSER FACE TO BE MOUNTED AT SAME HEGHT AS EXISTING DIFFUSERS. INSTALL DTS PROBE IN SUPPLY AIR PLENUM OR INTEGRAL DIFFUSER. 1 1 DR. 1 NIT TO CFM ' 1 SD 1 — ■ """■ _ 1 1 12600 IIMI1 11 t ''Q i 1 1 il I h PROVIDE N RE7UR • R BOOT SIZED CH LX/ h ; 1 PLENU DTOEXTERD4 BOOT TO HA 4 RA OP: IN IN TOP. � C DZC1 DZC2 MVP BUX L&f•%UStie tire O 00 00 0 0 cb T F � r .: PAINT ALL EXPOSED DUCTWORK TO MATCH THE SURROUNDING CEILING. REFER TO FINISH SCHEDULE ON ARCHITECTURAL SHEETS. s i m TT ........ ..,......■ 24 TON RTU Ell CE UNIT 7V -5000- CFM 54, 500 CFM OA I RTU - 31 DIGITAL ZONE CONTROLLERS SHALL BE MOUNTED ON THE BACK SIDE OF THE COLUMN AT 108' AFT. CIRCUIT LOCATION PER MANUFACTURERS SPECIFICATIONS. AT 72' AFF WHERE LOCATED IN OFFICE FOR UNIT NO. 2. SUPPLY AND RETURN GRILL FACES AND TRIM COLOR SHALL MATCH CEUNG. PROVIDE 'CONICAL SPIN IN' FITTINCS WITH INTEGRAL VOLUME DAMPERS AT EACH TAP. ALL SIDE WALL SUPPLY DIFFUSER BLADES ARE TO BE TURNED DOWN 15 DEGREES. REMOVE ALL EXISTING DIFFUSERS, GRILLES AND DUCTWORK ASSOCIATED WITH RTU BACK TO SUPPLY AND RETURN DROPS. SEAL OPENINGS NOT BENG REUSED. PATCH WALLS AND CEILINGS TO MATCH EXISTING. REFER ARCHITECTURAL ROOF MOUNTED DOWNBLAST EXHAUST FAN, DUCTWORK AND GRILLES ARE ETR. CLEAN GRILLES AND VERIFY THAT FAN IS NOT DAMAGED AND IN GOOD WORKING ORDER. REPORT ANY DEFICIENCIES' TO THE ARCHITECT OR OWNER MOUNT CO2 SENSOR AT 76" AFT. SENSOR SHALL BE FOR MONITORING ONLY. CONNECT TO BUILDING CONTROL SYSTEM. LOCATION OF LENNOX MOTORIZED ZONE DAMPER. COMPLETE WITH ?4 , TRANSFORMER LOCATE TRANSFORMER ABOVE OFFICE CEILING AT 12 —0 AFT. 12.5 TON 1?T71 E7R. REBALANCE UNIT TO 5000 CFM SA, 500 CFM OA. 20 0A TRANS AS HIGH AS POSSIBLE IN WALL , 1 1 1 _ .F S [ 1 THERMOSTAT MOUNTED AT 72' AFT. INSTALL TRANSFER GRILLE AS HIGH AS POSSIBLE IN WALL 0 .0n o ( D1 REFER TO 2 /MP1.1 DUCT SMOKE DETECTOR INSTALLED IN SUPPLY /RETURN OR AS REQU /RED BY THE FIRE MARSHALL HAVING JURISDICTION. PROVIDE ACCESS PANEL 1' INTERNAL LINER IN THE FIRST 10' -0' OF THE SPIRAL DUCT. BOTTOM OF STAGING AREA RIGID DUCT AT 14' -0" AFT. ALL EXPOSED DUCTWORK IN SALES AREA SHALL BE SPIRAL DUCTS. NO EXCEPTIONS OR ALT LOW VOLTAGE CONTROL WIRING FOR MOTOR /ZED ZONE DAMPER. WRING TO BE HIDDEN FROM VIEW. ROUTE WRING DIRECTLY ABOVE SUPPLY DUCT. Fl EX/BLE PORTIONS OF DUCT ARE NOT TO EXCEED 6=0' IN OVERALL LENGTH. CUT AND PATCH EXISTING CEILING AS REQUIRED FOR THE INSTALLATION OF NEW DUCTWORK AND A/R DEVICES. PATCH OPENINGS TO MATCH EX /5TMNG. REFER TO ARCHITECTURAL REQUIREMENTS COORDINATE NEW DUCTWORK WITH EXISTING CONDITIONS REROUTE DUCTWORK AS REQUIRED. REMOVE EX/ST/NG SUSPENDED AHU AND CONDENSING UNIT ON ROOF. REMOVE ALL DIFFUSERS, GRILLES', DUCTWORK AND PIPING ASSOCIATED WITH AHU BENG REMOVED. SEAL OPENINGS NOT BENG REUSED. PATCH ROOF, WALLS AND CE7UNGS TV MATCH DUSTING. REFER ARCHITECTURAL RECEIVE-? CLEAN, REPAINT AND REBALANCE EXISTING DROP BOX DIFFUSER AS NOV 2 6 20( 7 REQUIRED. PERMIT CEN" •E w 1- 0 j - r fi LJ l LL 0 0 r to 0 0 0 0 DRAWING CONTENTS: MECHANICAL PLANS DRAWING NO.: MP1.1 w 1- o CC 2 L fi rt t 1 1 1 1 I� } z o 1m o o 0 r LI 1 o • 0 1 = �¢ : 12 o r I � ° DRAWING CONTENTS: HVAC DETAILS DRAWING NO.: MP1.2 7 .----M,,,,.,,,,,,,. ' -.. AIR DAMPER MOTOR 24 VOLT POWER L�� STANDARD ROUND DUCT AS SCHEDULED IN -LINE DAMPER MOTORIZED SECTION 1 STANDARD i ` I ROUND � � . SUPP DAMP FROM THERMOSTAT ` \ TTORIZED SN \ 120 VOLT TO 24 VOLT TRANSFORMER INSTALL ABOVE CEILING 12' -6" A.F.F. >.... DUCT AS SCHEDULED NOTE: DUCT SENSOR ROOM THERMOSTAT TO BE SUPPLIED LOCATED PER MECHANICAL PLAN DAMPER (DOWN STREAM) LOW VOLTAGE WIRING FROM SENSOR REMOTE MOTORIZED DAMPER W/ SECT. TO THERMOSTAT SCALE: N.T.S. DUCT PENETRATION UL- WL7001 Formerly System No. 607) F Rating-1 Hr T Ratin 0 Hr M 01- .10 2 S r ' ''" -' $ , + .. 1- 1/4 "x1 -1/4 „x1/4„ W E 1 �6 / dr�d/ Jddd�fYd ./.�.rlyd/Jd�/A.Sy.Hd.�d °= ° EEp Ommal ...EE•02YA7■91697ASTA69:025605261/25266/407.ANC. ==== Q Q •--A 1. WALL ASSEMBLY - THE FIRE -RATED GYPSUM WALLBOARD /STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OF U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS -WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN. 2 1/2 IN WIDE AND SPACED MAX. 24 IN. OC. B. BATTS AND BLANKETS * - NOM 1 -1/2 IN. THICK GLASS FIBER BATTS FRICTION FITTED TO FILL INTERIOR OF STUD CAVITIES. C. WALLBOARD, GYPSUM * - TWO LAYERS OF NOM 1/2 IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX. AREA OF OPENING IS 48 SQ. IN. WITH MAX. DIMENSIONS OF 12 IN. 2. AIR DUCT- PREFABRICATED 24 MSG SHEET METAL AIR DUCT. MAX. CROSS SECTIONAL AREA OF DUCT IS 30 SQ. IN. WITH MAX. DIMENSION OF 10 IN. A MIN. 7/16 TO MAX. 1 IN. ANNULAR SPACE IS REQUIRED WITHIN THE FIRE STOP SYSTEM. AIR DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 3. FORMING MATERIAL * - MIN. 2 -1/2 IN. THICKNESS OF MIN. 3.5 PCF MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. FORMING MATERIAL TO BE RECESSED FROM BOTH SURFACES OF WALL TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL USG INTERIORS INC. - TYPE SAF 4. FILL, VOID OF CAVITY MATERIAL * - SEALANT- MIN. 1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL DRY MIX MATERIAL MIXED WITH WATER AT A RATE OF 2.1 PARTS MIX TO 1 LB. PART WATER BY WEIGHT IN ACCORDANCE WITH THE ACCOMPANYING INSTALLATION INSTRUCTIONS. UNITED STATES GYPSUM CO.- TYPE FC *BEARING THE UL CLASSIFICATION MARKING RATED DUCT PENETRATION 01\b, 1- 1/4 "x1 -1/4 "x1/4" r!. 1 1\r " 3/8 " -16 NUT 3/8 LOCK WASHER 3/8 " -16 NUT 3/8 -16 NUT 3/8 LOCK WASHER UNIT HEATER MOUNTING FLANGE As I�� -•m.- •-• 3/8 " -16 ROD 3/8" FLAT WASHER 3/8 " -16 NUT 1 ` I` ,� Iii 12' -6” AFT' 4 BOTTOM OF UNIT UNIT HEATER SUPPORT SCALE: N.T.S. SCALE: N.T.S. Fr-tolTED NOV 2 6 2007 PERMIT CENTER w 1- o CC 2 L fi rt t 1 1 1 1 I� } z o 1m o o 0 r LI 1 o • 0 1 = �¢ : 12 o r I � ° DRAWING CONTENTS: HVAC DETAILS DRAWING NO.: MP1.2 15A: Heating, Ventilating, and Air Conditioning: 15A 1 GENERAL INSTRUCTIONS 15A 1 -1 GENERAL REQUIREMENTS REQUIREMENTS UNDER DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. CONTRACTOR SHALL BECOME THOROUGHLY ACQUAINTED WITH ITS CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION INCLUDES MATERIAL, EQUIPMENT, APPLIANCES, TRANSPORTATION, SERVICES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. 15A 1 -2 DEFINITIONS FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITEM WILL BE FURNISHED BY THE OWNER OR OTHERS. IT IS TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDENTAL TO THE WORK, INCLUDING SERVICES NECESSARY FOR PROPER INSTALLATION AND OPERATION. THE INSTALLATION SHALL BE INCLUDED UNDER THE GUARANTEE REQUIRED BY THIS DIVISION. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT ". AHJ: THE LOCAL CODE AND /OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. THE TERMS "APPROVED EQUAL ", "EQUIVALENT ", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 15A 1 -3 PREBID SITE VISIT PRIOR TO SUBMITTING BID, VISIT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 15A 1 -4 MATERIAL AND WORKMANSHIP PROVIDE NEW MATERIAL, EQUIPMENT, AND APPARATUS UNDER THIS CONTRACT UNLESS OTHERWISE STATED HEREIN, OF BEST QUALITY NORMALLY USED FOR THE PURPOSE IN GOOD COMMERCIAL PRACTICE, AND FREE FROM DEFECTS. MODEL NUMBERS LISTED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT NECESSARILY INTENDED TO DESIGNATE THE REQUIRED TRIM, WRITTEN DESCRIPTIONS OF THE TRIM GOVERN MODEL NUMBERS. PIPE, PIPE FITTINGS, PIPE SPECIALTIES AND VALVES SHALL BE MANUFACTURED IN PLANTS LOCATED IN THE UNITED STATES. WORK PERFORMED UNDER THIS CONTRACT SHALL PROVIDE A NEAT AND "WORKMANLIKE" APPEARANCE WHEN COMPLETED, TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER. WORKMANSHIP SHALL BE THE FINEST POSSIBLE BY EXPERIENCED MECHANICS. INSTALLATIONS SHALL COMPLY WITH APPLICABLE CODES AND LAWS. THE COMPLETE INSTALLATION SHALL FUNCTION AS DESIGNED AND INTENDED WITH RESPECT TO EFFICIENCY, CAPACITY, NOISE LEVEL, ETC. ABNORMAL NOISE CAUSED BY RATTLING EQUIPMENT, PIPING, DUCTS, AIR DEVICES, AND SQUEAKS IN ROTATING COMPONENTS WILL NOT BE ACCEPTABLE. IN GENERAL, MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTED. REMOVE FROM THE PREMISES WASTE MATERIAL PRESENT AS A RESULT OF WORK, INCLUDING CARTONS, CRATING, PAPER, STICKERS, AND /OR EXCAVATION MATERIAL NOT USED IN BACKFILLING, ETC. CLEAN EQUIPMENT INSTALLED UNDER THIS CONTRACT TO PRESENT A NEAT AND CLEAN INSTALLATION AT THE TERMINATION OF THE WORK. REPAIR OR REPLACE PUBLIC AND PRIVATE PROPERTY DAMAGED AS A RESULT OF WORK PERFORMED UNDER THIS CONTRACT TO THE SATISFACTION OF AUTHORITIES AND REGULATIONS HAVING JURISDICTION. 15A 1-5 COORDINATION COORDINATE WORK WITH THAT OF OTHER TRADES SO THAT THE VARIOUS COMPONENTS OF THE SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, AND WILL ALLOW PROPER SERVICE ACCESS TO THOSE ITEMS REQUIRING MAINTENANCE. COMPONENTS WHICH ARE INSTALLED WITHOUT REGARD TO THE ABOVE SHALL BE RELOCATED AT NO ADDITIONAL COST TO THE OWNER. UNLESS OTHERWISE INDICATED, THE GENERAL CONTRACTOR WILL PROVIDE CHASES AND OPENINGS IN BUILDING CONSTRUCTION REQUIRED FOR INSTALLATION OF THE SYSTEMS SPECIFIED HEREIN. CONTRACTOR SHALL FURNISH THE GENERAL CONTRACTOR WITH INFORMATION WHERE CHASES AND OPENINGS ARE REQUIRED. KEEP INFORMED AS TO THE WORK OF OTHER TRADES ENGAGED IN THE CONSTRUCTION OF THE PROJECT, AND EXECUTE WORK IN A MANNER AS TO NOT INTERFERE WITH OR DELAY THE WORK OF OTHER TRADES. FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALE DIMENSIONS. CONTRACTOR SHALL TAKE HIS OWN MEASUREMENTS AT THE BUILDING, AS VARIATIONS MAY OCCUR. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION. PROVIDE MATERIALS WITH TRIM THAT WILL PROPERLY FIT THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY INSTALLED. MODEL NUMBERS LISTED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT INTENDED TO DESIGNATE THE REQUIRED TRIM. 15A 1 -6 ORDINANCES AND CODES WORK PERFORMED UNDER THIS CONTRACT SHALL, AT A MINIMUM, BE IN CONFORMANCE WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES HAVING JURISDICTION. EQUIPMENT FURNISHED AND ASSOCIATED INSTALLATION WORK PERFORMED UNDER THIS CONTRACT SHALL BE IN STRICT COMPLIANCE WITH CURRENT APPLICABLE CODES ADOPTED BY THE LOCAL AHJ INCLUDING ANY AMENDMENTS AND STANDARDS AS SET FORTH BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), UNDERWRITERS LABORATORIES (UL), OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME), AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS (ASHRAE), AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) AND OTHER NATIONAL STANDARDS AND CODES WHERE APPLICABLE. WHERE THE CONTRACT DOCUMENTS EXCEED THE REQUIREMENTS OF THE REFERENCED CODES, STANDARDS, ETC., THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE. PROCURE AND PAY FOR PERMITS AND LICENSES REQUIRED FOR THE ACCOMPLISHMENT OF THE WORK HEREIN DESCRIBED. WHERE REQUIRED, OBTAIN, PAY FOR AND FURNISH CERTIFICATES OF INSPECTION TO OWNER. CONTRACTOR WILL BE HELD RESPONSIBLE FOR VIOLATIONS OF THE LAW. 15A 1 -7 PROTECTION OF EQUIPMENT AND MATERIALS STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO JOB SITE. COVER WITH WATERPROOF, TEAR- RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC AS REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION ACTIVITIES WILL BE REJECTED, AND CONTRACTOR IS OBLIGATED TO FURNISH NEW EQUIPMENT AND MATERIAL OF A LIKE KIND. KEEP PREMISES BROOM CLEAN FROM FOREIGN MATERIAL CREATED DURING WORK PERFORMED UNDER THIS CONTRACT. PIPING, EQUIPMENT, ETC. SHALL HAVE A NEAT AND CLEAN APPEARANCE AT THE TERMINATION OF THE WORK. PLUG OR CAP OPEN ENDS OF DUCTWORK AND PIPING SYSTEMS WHILE STORED AND INSTALLED DURING CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF DEBRIS INTO THE SYSTEMS. 15A 1 -8 SUBSTITUTIONS THE BASE BID SHALL INCLUDE ONLY THE PRODUCTS FROM MANUFACTURERS SPECIFICALLY NAMED IN THE DRAWINGS AND SPECIFICATIONS_ NO SUBSTITUTION WILL BE CONSIDERED PRIOR TO RECEIPT OF BIDS UNLESS WRITTEN REQUEST FOR APPROVAL TO BID HAS BEEN RECEIVED BY THE ENGINEER AT LEAST TEN CALENDAR DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS. EACH SUCH REQUEST SHALL INCLUDE THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT IS TO BE SUBSTITUTED AND A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE INCLUDING DRAWINGS, CUTS, PERFORMANCE AND TEST DATA AND OTHER INFORMATION NECESSARY FOR AN EVALUATION. A STATEMENT SLIIING FORTH CHANGES IN OTHER MATERIALS, EQUIPMENT OR OTHER WORK THAT INCORPORATION OF THE SUBSTITUTE WOULD REQUIRE SHALL BE INCLUDED. THE BURDEN OF PROOF OF THE MERIT OF THE PROPOSED SUBSTITUTE IS UPON THE PROPOSER. THE ENGINEER'S DECISION OF APPROVAL OR DISAPPROVAL TO BID OF A PROPOSED SUBSTITUTION SHALL BE FINAL. THE TERMS "APPROVED ", "APPROVED EQUAL ", AND "EQUAL" REFER TO APPROVAL BY THE ENGINEER AS AN ACCEPTABLE ALTERNATE BID. NO SUBSTITUTIONS WILL BE CONSIDERED THAT ARE NOT BID AS AN ALTERNATE. NO MATERIAL SUBSTITUTIONS SHALL BE CONSIDERED FOR APPROVAL PRIOR TO AWARD OF CONTRACT. COORDINATE AND VERIFY WITH OTHER TRADES WHETHER OR NOT THE SUBSTITUTED EQUIPMENT CAN BE INSTALLED AS SHOWN ON THE CONSTRUCTION DRAWINGS WITHOUT MODIFICATION TO ASSOCIATED SYSTEMS OR ARCHITECTURAL OR ENGINEERING DESIGN. INCLUDE ADDITIONAL COSTS FOR ARCHITECTURAL AND ENGINEERING DESIGN FEES IN BID IF DRAWING MODIFICATIONS ARE REQUIRED BECAUSE OF SUBSTITUTED EQUIPMENT. 15A 1 -9 SHOP DRAWINGS UPON BEING AWARDED A CONTRACT, SUBMIT TO THE ARCHITECT FOR APPROVAL, SIX (6) COPIES OF MANUFACTURER'S SHOP DRAWINGS FOR EQUIPMENT TO BE FURNISHED UNDER THIS CONTRACT, ITEMS REQUIRING COORDINATION BETWEEN CONTRACTORS AND SHEET METAL DUCTWORK FABRICATION DRAWINGS. BEFORE SUBMITTING SHOP DRAWINGS AND MATERIAL LISTS, VERIFY THAT EQUIPMENT SUBMITTED IS MUTUALLY COMPATIBLE AND SUITABLE FOR THE INTENDED USE, AND WILL FIT THE AVAILABLE SPACE AND ALLOW AMPLE ROOM FOR MAINTENANCE. THE ENGINEER'S CHECKING AND SUBSEQUENT APPROVAL OF SUCH SHOP DRAWINGS WILL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN DIMENSIONS, DETAILS, SIZE OF MEMBERS, QUANTITIES, OMISSIONS OF COMPONENTS OR FITTINGS; COORDINATION OF ELECTRICAL REQUIREMENTS; OR FOR COORDINATING ITEMS WITH ACTUAL BUILDING CONDITIONS. PROCEED WITH THE PROCUREMENT AND INSTALLATION OF EQUIPMENT ONLY AFTER RECEIVING APPROVED SHOP DRAWINGS RELATIVE TO EACH ITEM. CATALOG DATA SHALL BE PROPERLY BOUND, IDENTIFIED, INDEXED AND TABBED IN A 3 -RING BINDER. EACH ITEM OR MODEL NUMBER SHALL BE CLEARLY MARKED AND ACCESSORIES INDICATED. LABEL THE CATALOG DATA WITH THE EQUIPMENT IDENTIFICATION ACRONYM OR NUMBER AS USED ON THE DRAWINGS AND INCLUDE PERFORMANCE CURVES, CAPACITIES, SIZES, MATERIALS, FINISHES, WIRING DIAGRAMS AND DEVIATIONS FROM SPECIFIED EQUIPMENT OR MATERIALS. MARK OUT INAPPLICABLE ITEMS. SHOP DRAWINGS WILL BE RETURNED WITHOUT REVIEW IF THE ABOVE MENTIONED REQUIREMENTS ARE NOT MET. 15A 1 -10 ELECTRONIC DRAWING FILES IN PREPARATION OF SHOP DRAWINGS, CONTRACTOR MAY, AT HIS OPTION, OBTAIN ELECTRONIC DRAWING FILES IN AUTOCAD OR DXF FORMAT ON 3.5 INCH FLOPPY DISK, 100 MB ZIP DISK OR CD -ROM DISK, AS DESIRED, FROM THE ENGINEER FOR A SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING SET UP TO 12 SHEETS AND $15 PER SHEET FOR EACH ADDITIONAL SHEET. CONTRACTOR SHALL CONTACT THE ARCHITECT FOR WRITTEN AUTHORIZATION AND ENGINEER FOR THE NECESSARY RELEASE AGREEMENT FORM AND TO SPECIFY SHIPPING METHOD AND DRAWING FORMAT. IN ADDITION TO PAYMENT, ARCHITECT'S WRITTEN AUTHORIZATION AND ENGINEER'S RELEASE AGREEMENT FORM MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. 15A 1-11 OPERATION AND MAINTENANCE INSTRUCTIONS DURING THE COURSE OF CONSTRUCTION, COLLECT AND COMPILE A COMPLETE BROCHURE OF EQUIPMENT FURNISHED AND INSTALLED ON THIS PROJECT. INCLUDE OPERATIONAL AND MAINTENANCE INSTRUCTIONS, MANUFACTURER'S CATALOG SHEETS, WIRING DIAGRAMS, PARTS LISTS, APPROVED SHOP DRAWINGS, AND DESCRIPTIVE LITERATURE AS FURNISHED BY THE EQUIPMENT MANUFACTURER. INCLUDE AN INSIDE COVER SHEET THAT LISTS THE PROJECT NAME, DATE, OWNER, ARCHITECT, CONSULTING ENGINEER, GENERAL CONTRACTOR, SUB - CONTRACTOR, AND AN INDEX OF CONTENTS. SUBMIT THREE COPIES OF LITERATURE BOUND IN APPROVED BINDERS WITH INDEX AND TABS SEPARATING EQUIPMENT TYPES TO THE ARCHITECT AT THE TERMINATION OF THE WORK. PAPER CLIPS, STAPLES, RUBBER BANDS, AND MAILING ENVELOPES ARE NOT CONSIDERED APPROVED BINDERS. FINAL APPROVAL OF MECHANICAL SYSTEMS INSTALLED UNDER THIS CONTRACT WILL BE WITHHELD UNTIL THIS EQUIPMENT BROCHURE IS RECEIVED AND DEEMED COMPLETE BY THE ARCHITECT AND ENGINEER. INSTRUCT WORKMEN TO SAVE REQUIRED LITERATURE SHIPPED WITH THE EQUIPMENT ITSELF, FOR INCLUSION IN THIS BROCHURE. PROVIDE "AS- BUILT" DRAWINGS (SEE DIVISION 1 AND GENERAL CONDITIONS). 15A 1 -12 TRAINING AT A TIME MUTUALLY AGREED UPON BETWEEN THE OWNER AND CONTRACTOR, PROVIDE THE SERVICES OF A FACTORY TRAINED AND AUTHORIZED REPRESENTATIVE TO TRAIN OWNER'S DESIGNATED PERSONNEL ON THE OPERATION AND MAINTENANCE OF THE EQUIPMENT PROVIDED FOR THIS PROJECT. PROVIDE TRAINING TO INCLUDE BUT NOT BE LIMITED TO AN OVERVIEW OF THE SYSTEM AND /OR EQUIPMENT AS IT RELATES TO THE FACILITY AS A WHOLE; OPERATION AND MAINTENANCE PROCEDURES AND SCHEDULES RELATED TO STARTUP AND SHUTDOWN, TROUBLESHOOTING, SERVICING, PREVENTIVE MAINTENANCE AND APPROPRIATE OPERATOR INTERVENTION; AND REVIEW OF DATA INCLUDED IN THE OPERATION AND MAINTENANCE MANUALS. SUBMIT A CERTIFICATION LETTER TO THE ARCHITECT STATING THAT THE OWNER'S DESIGNATED REPRESENTATIVE HAS BEEN TRAINED AS SPECIFIED HEREIN. LETTER SHALL INCLUDE DATE, TIME, ATTENDEES AND SUBJECT OF TRAINING. THE CONTRACTOR AND THE OWNER'S REPRESENTATIVE SHALL SIGN THE CERTIFICATION LLIIER INDICATING AGREEMENT THAT THE TRAINING HAS BEEN PROVIDED. SCHEDULE OWNER TRAINING WITH AT LEAST 7 DAYS' ADVANCE NOTICE. 15A 1 -14 WARRANTIES WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DIVISION 1. WARRANTIES SHALL INCLUDE LABOR AND MATERIAL. MAKE REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER OR OWNER. AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. 15A 1 -15 CUTTING AND PATCHING PERFORM CUTTING OF WALLS, FLOORS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK UNDER THIS SECTION. OBTAIN PERMISSION FROM THE ARCHITECT PRIOR TO CUTTING. DO NOT CUT OR DISTURB STRUCTURAL MEMBERS WITHOUT PRIOR APPROVAL FROM THE ARCHITECT. CUT HOLES AS SMALL AS POSSIBLE. GENERAL CONTRACTOR SHALL PATCH WALLS, FLOORS, ETC. AS REQUIRED BY WORK UNDER THIS SECTION. PATCHING SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION. REPAIR AND REFINISH AREAS DISTURBED BY WORK TO THE CONDITION OF ADJOINING SURFACES IN A MANNER SATISFACTORY TO THE ARCHITECT. 15A 1 -16 ROUGH -IN COORDINATE WITHOUT DELAY ROUGHING -IN WITH GENERAL CONSTRUCTION. CONCEAL PIPING AND CONDUIT ROUGH -IN EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE SHOWN. 15A 1 -18 STRUCTURAL STEEL STRUCTURAL STEEL USED FOR SUPPORT OF EQUIPMENT, DUCTWORK AND PIPING SHALL BE NEW, CLEAN, AND CONFORM TO ASTM DESIGNATION A -36. SUPPORT MECHANICAL COMPONENTS FROM THE BUILDING STRUCTURE. DO NOT SUPPORT MECHANICAL COMPONENTS FROM CEILINGS, OTHER MECHANICAL OR ELECTRICAL COMPONENTS, AND OTHER NON- STRUCTURAL ELEMENTS. 15A 1 -19 ACCESS DOORS PROVIDE ACCESS DOORS IN CEILINGS, WALLS, ETC. WHERE INDICATED OR REQUIRED FOR ACCESS OR MAINTENANCE TO CONCEALED VALVES AND EQUIPMENT INSTALLED UNDER THIS SECTION. PROVIDE CONCEALED HINGES, SCREWDRIVER -TYPE LOCK, ANCHOR STRAPS; MANUFACTURED BY MILCOR, ZURN, TITUS, OR EQUAL. OBTAIN ARCHITECT'S APPROVAL OF TYPE, SIZE, LOCATION AND COLOR BEFORE ORDERING. 1 5A 1 -20 PENETRATIONS SEAL MECHANICAL FLOOR, EXTERIOR WALL AND ROOF PENETRATIONS WATERTIGHT AND WEATHERTIGHT. SEAL AROUND MECHANICAL PENETRATIONS WITH 3M CP -25 FIRE BARRIER CAULK (THICKNESS AS REQUIRED AND RECOMMENDED BY MANUFACTURER) TO MAINTAIN FIRE RESISTANCE RATING OF FIRE -RATED ASSEMBLIES. PROVIDE PREFABRICATED ROOF CURBS MANUFACTURED BY CUSTOM CURB, INC., PATE COMPANY, THYCURB OR APPROVED EQUAL. PROVIDE ROOF CURB WITH FACTORY INSTALLED WOOD NAILER; WELDED, 18 GAUGE GALVANIZED STEEL SHELL, BASE PLATE AND FLASHING; 1-1/2" THICK, 3 POUND RIGID INSULATION; FULLY MITERED 3 -INCH RAISED CANT; COVER OF WEATHER- RESISTANT, WEATHER -PROOF MATERIAL AND PIPE COLLAR OF WEATHER - RESISTANT MATERIAL WITH STAINLESS STEEL PIPE CLAMPS 15A 1 -21 AIR FILTERS PROVIDE FARR 30/30 PLEATED, THROWAWAY TYPE FILTERS, UNLESS OTHERWISE INDICATED. AIR UNITS SHALL HAVE NEW FILTERS INSTALLED WHEN THEY ARE OPERATED BEFORE FINAL ACCEPTANCE. FILTERS SHALL BE MANUFACTURED BY AMERICAN AIR FILTER, FARR, FLANDERS, OR APPROVED EQUAL. IF HVAC EQUIPMENT IS USED DURING THE CONSTRUCTION PERIOD, CONTRACTOR SHALL PROVIDE ONE SET OF FILTERS WHEN THE UNIT IS STARTED AND REPLACE FILTERS WHEN NEEDED, BUT NOT LESS THAN EVERY MONTH. ON THE DAY OF SUBSTANTIAL COMPLETION, THE CONTRACTOR SHALL CLEAN THE UNIT AND PROVIDE A NEW SET OF FILTERS IN THE UNIT. 15A 1 -23 ELECTRICAL WIRING LINE VOLTAGE WIRING SHALL BE PROVIDED BY DIVISION 16. LINE VOLTAGE CONTROL AND INTERLOCK WIRING FOR MECHANICAL SYSTEMS SHALL ALSO BE PROVIDED BY DIVISION 16 CONTRACTOR. LOW VOLTAGE CONTROL WIRING SHALL BE PROVIDED BY THE DIVISION 15 CONTRACTOR. FURNISH WIRING DIAGRAMS TO THE DIVISION 16 CONTRACTOR AS REQUIRED FOR PROPER EQUIPMENT HOOKUP. COORDINATE WITH THE DIVISION 16 CONTRACTOR THE ACTUAL WIRE SIZING AMPS FOR MECHANICAL EQUIPMENT (FROM THE EQUIPMENT NAMEPLATE) TO ENSURE PROPER INSTALLATION. 15A 1 -24 REFRIGERANT AND OIL PROVIDE FULL REFRIGERANT AND OIL CHARGE IN EXISTING AIR CONDITIONING REFRIGERATION SYSTEMS. 15A 1 -25 FINAL TESTING AND ADJUSTMENTS PERFORM TEST READINGS ON FANS, UNITS, COILS, ETC. AND ADJUST EQUIPMENT TO DELIVER SPECIFIED AMOUNTS OF AIR. PREPARE TESTING AND BALANCING REPORT LOG SHOWING AIR SUPPLY QUANTITIES, AIR ENTERING AND LEAVING TEMPERATURES AND PRESSURES, FAN AND UNIT TEST READINGS, MOTOR VOLTAGE AND AMP DRAWS, ETC., AND SUBMIT SIX COPIES OF THE FINAL COMPILATION OF DATA TO THE ARCHITECT FOR EVALUATION AND APPROVAL BEFORE FINAL INSPECTION OF THE PROJECT. BALANCE AIR SYSTEMS TO WITHIN PLUS OR MINUS 10 PERCENT FOR TERMINAL DEVICES AND BRANCH LINES AND PLUS OR MINUS 5 PERCENT FOR MAIN DUCTS AND AIR HANDLING EQUIPMENT OF THE AMOUNT OF AIR SHOWN ON THE DRAWINGS. FURTHER ADJUSTMENTS SHALL BE MADE TO OBTAIN UNIFORM TEMPERATURE IN SPACES. ADJUST EQUIPMENT TO OPERATE AS INTENDED BY THE SPECIFICATION. ALIGN BEARINGS AND REPLACE BEARINGS THAT HAVE DIRT OR FOREIGN MATERIAL IN THEM WITH NEW BEARINGS WITHOUT ADDITIONAL COST TO THE OWNER. BALANCE CONTRACTOR SHALL INCLUDE IN THE REPORT ANY IMPROPERLY INSTALLED OR MISSING BALANCING DEVICES THAT WOULD NEGATIVELY IMPACT THE SYSTEM OPERATION. ADJUST THERMOSTATS AND CONTROL DEVICES TO OPERATE AS INTENDED. ADJUST BURNERS, FANS, ETC. FOR PROPER AND EFFICIENT OPERATION. CERTIFY TO ARCHITECT THAT ADJUSTMENTS HAVE BEEN MADE AND THAT SYSTEM IS OPERATING SATISFACTORILY. FURTHER ADJUSTMENTS SHALL BE MADE TO OBTAIN UNIFORM TEMPERATURE IN SPACES. CALIBRATE, SET, AND ADJUST AUTOMATIC TEMPERATURE CONTROLS. CHECK PROPER SEQUENCING OF INTERLOCK SYSTEMS, AND OPERATION OF SAFETY CONTROLS. 15A 1 -26 EQUIPMENT FURNISHED BY OTHERS PROVIDE NECESSARY EQUIPMENT AND ACCESSORIES THAT ARE NOT PROVIDED BY THE EQUIPMENT SUPPLIER OR OWNER TO COMPLETE INSTALLATION OF COOKING EQUIPMENT, WASHING EQUIPMENT, ETC., FURNISHED BY OTHERS, IN LOCATIONS AS INDICATED ON THE DRAWINGS AND /OR DESCRIBED IN THE GENERAL NOTES TO THIS CONTRACTOR. EQUIPMENT AND ACCESSORIES NOT PROVIDED BY THE EQUIPMENT SUPPLIER MAY INCLUDE FLUES, VENTS, INTAKES, ASSOCIATED ROOF JACKS AND CAPS TO OUTDOORS, DAMPERS, IN -LINE FANS, ROOF FANS, CONTROL INTERLOCKS, ETC. AS REQUIRED FOR PROPER OPERATION OF THE COMPLETE SYSTEM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECT ROUGH -IN DIMENSIONS, AND SHALL VERIFY SAME WITH ARCHITECT AND /OR EQUIPMENT SUPPLIER PRIOR TO SERVICE INSTALLATIONS. 15A 1 -27 MISCELLANEOUS REMODELING WORK REMOVE ALL UNUSED EQUIPMENT, DUCTWORK, PIPING AND ASSOCIATED SUPPORTS. CAP DUCTWORK AND PIPING AT MAINS AND SEAL AIR AND WATER TIGHT. PROVIDE ITEMS OF HVAC SYSTEMS MODIFICATION REQUIRED BECAUSE OF BUILDING REMODELING, AS NOTED ON THE DRAWINGS OR NECESSARY FOR PROPER OPERATION. MATCH EXISTING MATERIALS AND CONSTRUCTION TECHNIQUES WHEN MODIFYING EXISTING SYSTEMS UNLESS SPECIFIED OTHERWISE. COORDINATE ADDITIONAL REQUIREMENTS WITH GENERAL CONTRACTOR AND ARCHITECT. SEAL AIRTIGHT EXISTING DUCTWORK REQUIRED TO BE ABANDONED IN PLACE OR NOT IN USE AT THE TERMINATION OF THE WORK. CAP AND SEAL WEATHERTIGHT EXISTING ROOF CURBS AND ROOF OPENINGS TO BE ABANDONED IN PLACE AS A RESULT OF EQUIPMENT REMOVAL. CLEAN AND REBALANCE EXISTING DUCTWORK, DIFFUSERS, REGISTERS, AND GRILLES INTENDED FOR REUSE AS REQUIRED OR AS INDICATED ON DRAWINGS. CLEAN AND REFURBISH EXISTING HVAC EQUIPMENT INTENDED FOR REUSE AS REQUIRED FOR PROPER OPERATION INCLUDING REPLACEMENT OF FILTERS, BELTS, MOTORS, REMOTE CONTROLS, AND SAFETY INTERLOCKS. 15A 1 -28 BUILDING OPERATION COMPLY WITH THE SCHEDULE OF OPERATIONS AS OUTLINED IN THE ARCHITECTURAL PORTIONS OF THIS SPECIFICATION. BUILDING SHALL BE IN CONTINUOUS OPERATION. ACCOMPLISH WORK REQUIRING INTERRUPTION OF BUILDING OPERATION AT A TIME WHEN THE BUILDING IS NOT IN OPERATION, AND ONLY WITH WRITTEN APPROVAL OF BUILDING OWNER AND /OR TENANT. COORDINATE INTERRUPTION OF BUILDING OPERATION WITH THE OWNER AND /OR TENANT A MINIMUM OF SEVEN DAYS IN ADVANCE OF WORK. 15A 2 INSULATION AND SHEET METAL WORK 15A 2 -1 DUCT INSULATION PROVIDE DUCT LINER IN RECTANGULAR AND ROUND SUPPLY AND RETURN AIR DUCTWORK. LINER SHALL BE 1" (MINIMUM R -4.2) THICK, 3 POUND DENSITY FIBERGLASS, CERTAINTEED CORP. "TOUGHGARD" OR OWENS- CORNING "AEROFLEX DUCT LINER. LINER SURFACE SHALL SERVE AS A BARRIER AGAINST INFILTRATION OF DUST AND DIRT, SHALL MEET ASTM C 1338 FOR FUNGI RESISTANCE AND SHALL BE CLEANABLE USING DUCT CLEANING METHODS AND EQUIPMENT OUTLINED BY NORTH AMERICAN INSULATION MANUFACTURERS ASSOCIATION (NAIMA) DUCT CLEANING GUIDE. INSTALL WITH LINER ADHESIVE AND MECHANICAL FASTENERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. DUCTWORK SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INCREASE SHEET METAL BY LINER THICKNESS IN BOTH DIRECTIONS WHERE LINER IS INSTALLED. COVER CONCEALED RIGID ROUND AND RECTANGULAR SUPPLY AND RETURN AIR DUCTWORK WITH 1 -1/2" (MINIMUM R -4.2) THICK DUCT WRAP, CERTAINTEED OR EQUAL OWENS- CORNING, 3/4 POUND DENSITY, WITH HEAVY -DUTY FOIL- SCRIM -KRAFT FACING, AND WITH JOINTS TAPED WITH 3" WIDE FOIL TAPE. INSULATING MATERIALS, ADHESIVES, COATINGS, ETC., SHALL NOT EXCEED FLAME SPREAD RATING OF 25 AND SMOKE DEVELOPED RATING OF 50 PER ASTM E 84. CONTAINERS FOR MASTICS AND ADHESIVES SHALL HAVE U.L. LABEL. 15A 2 -2 DUCTWORK PROVIDE GALVANIZED STEEL DUCTWORK AND HOUSINGS AS SHOWN ON DRAWINGS. CONSTRUCT DUCTWORK INCLUDING FITTINGS AND TRANSITIONS IN CONFORMANCE WITH CURRENT SMACNA STANDARDS RELATIVE TO GAUGE, BRACING, JOINTS, ETC. MINIMUM THICKNESS OF DUCT SHALL BE 26 -GAUGE SHEET METAL. REINFORCE HOUSINGS AND DUCTWORK OVER 30" WITH 1 -1/4" ANGLES NOT LESS THAN 5' -6" ON CENTERS, AND CLOSER IF REQUIRED FOR SUFFICIENT RIGIDITY TO PREVENT VIBRATION. SUPPORT HORIZONTAL RUNS OF DUCT FROM STRAP IRON HANGERS ON CENTERS NOT TO EXCEED 8' -O ". DO NOT SUPPORT CEILING GRID, CONDUITS, PIPES, EQUIPMENT, ETC. FROM DUCTWORK. COORDINATE ROUTING OF DUCTWORK WITH OTHER CONTRACTORS SUCH THAT PIPING, ELECTRICAL CONDUIT, AND ASSOCIATED SUPPORTS ARE NOT ROUTED THROUGH THE DUCTWORK. CONSTRUCT SUPPLY DUCTS TO MEET SMACNA POSITIVE PRESSURE OF 2" W.G. CONSTRUCT RETURN, OUTDOOR AND EXHAUST DUCTWORK UPSTREAM OF FANS TO MEET SMACNA NEGATIVE PRESSURE OF 1" W.G. EXPOSED DUCTWORK TO BE FIELD PAINTED SHALL HAVE GALVANIZED METAL PRIMER APPLIED IN THE SHOP AFTER FABRICATION AND PRIOR TO SHIPPING. SEAL DUCTWORK WITH HEAVY LIQUID SEALANT, HARDCAST IRONGRIP 601, DESIGN POLYMER DP 1010 , UNITED MCGILL DUCT SEALER OR APPROVED EQUAL, APPLIED ACCORDING TO SEALANT MANUFACTURER'S INSTRUCTIONS. FOR DUCTS WITH PRESSURE CLASSIFICATION OF 2" W.G. SEAL LONGITUDINAL AND TRANSVERSE DUCTWORK JOINTS AIRTIGHT TO MEET SMACNA CLASS B. FOR DUCTS WITH PRESSURE CLASSIFICATION LESS THAN 2" W.G. SEAL TRANSVERSE JOINTS AIRTIGHT TO MEET SMACNA CLASS C. TAPES AND MASTICS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A. PROVIDE RADIUS ELBOWS, TURNS, AND OFFSETS WITH A MINIMUM CENTERLINE RADIUS OF 1-1/2 TIMES THE DUCT WIDTH. WHERE SPACE DOES NOT PERMIT FULL RADIUS ELBOWS, PROVIDE SHORT RADIUS ELBOWS WITH A MINIMUM OF TWO CONTINUOUS SPLITTER VANES. VANES SHALL BE THE ENTIRE LENGTH OF THE BEND. PROVIDE MITERED ELBOWS WHERE SPACE DOES NOT PERMIT RADIUS ELBOWS, WHERE SHOWN ON THE DRAWINGS, OR AT THE OPTION OF THE CONTRACTOR WITH THE ENGINEER'S APPROVAL. MITERED ELBOWS LESS THAN 45 DEGREES SHALL NOT REQUIRE TURNING VANES. MITERED ELBOWS 45- DEGREES AND GREATER SHALL HAVE SINGLE THICKNESS TURNING VANES OF SAME GAUGE AS DUCTWORK, RIGIDLY FASTENED WITH GUIDE STRIPS IN DUCTWORK. VANES FOR MITERED ELBOWS SHALL BE PROVIDED IN ALL SUPPLY AND EXHAUST DUCTWORK AND IN RETURN AND OUTSIDE AIR DUCTWORK THAT HAS AN AIR VELOCITY EXCEEDING 1000 FPM. DO NOT INSTALL VANES IN GREASE DUCTWORK. DUCTS SHALL BE CONNECTED TO FANS, FAN CASINGS AND FAN PLENUMS BY MEANS OF FLEXIBLE CONNECTORS. FLEXIBLE CONNECTORS SHALL BE NEOPRENE COATED GLASS CLOTH CANVAS CONNECTIONS, DURO -DYNE, ELLEN, VENTFABRIC OR EQUAL. FLEXIBLE CONNECTORS SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPED RATING NOT HIGHER THAN 50. MAKE AIRTIGHT JOINTS AND INSTALL WITH MINIMUM 1-1/2" SLACK. PROVIDE BALANCING DAMPERS, MANUFACTURED BY RUSKIN, GREENHECK, NAILOR INDUSTRIES, CESCO, LOUVERS & DAMPERS, POTTORFF OR APPROVED EQUAL, WHERE SHOWN ON DRAWINGS AND WHEREVER NECESSARY FOR COMPLETE CONTROL OF AIR FLOW. SPLITTER DAMPERS SHALL BE CONTROLLED BY LOCKING QUADRANTS; PROVIDE YOUNG REGULATOR OR VENTLOK END BEARINGS FOR THE DAMPER ROD. RECTANGULAR VOLUME DAMPERS SHALL BE OPPOSED BLADE INTERLOCKING TYPE. ROUND VOLUME DAMPERS SHALL BE BUTTERFLY TYPE CONSISTING OF CIRCULAR BLADE MOUNTED TO A SHAFT. DAMPER LEAKAGE FOR OUTSIDE AIR DAMPERS SHALL NOT EXCEED 6.5 CFM /SQUARE FOOT IN FULL CLOSED POSITION AT 4" WG PRESSURE DIFFERENTIAL ACROSS DAMPER. REFERENCE MANUFACTURER AND MODEL NUMBER FOR OUTSIDE AIR DAMPERS IS RUSKIN MODEL CD -50. PROVIDE FLEXMASTER MODEL STO OR EQUAL 45 DEGREE RECTANGULAR /ROUND SIDE TAKEOFF FITTING WITH MODEL SLBO DOUBLE BEARING DAMPER WITH INSULATION BUILD OUT FOR ROUND DUCTWORK BRANCH TAKEOFFS TO INDIVIDUAL AIR DEVICES. WHERE ACCESS TO DAMPERS THROUGH A HARD CEILING IS REQUIRED, PROVIDE A METROPOLITAN AIR TECHNOLOGY MODEL RT -250 OR EQUAL BY YOUNG'S REGULATOR CONCEALED, CABLE OPERATED VOLUME DAMPER WITH REMOTE OPERATOR. DAMPER SHALL BE ADJUSTABLE THROUGH THE DIFFUSER FACE OR FRAME WITH STANDARD 1/4" NUTDRIVER OR FLAT SCREWDRIVER. CABLE ASSEMBLY SHALL ATTACH TO DAMPER AS ONE PIECE WITH NO LINKAGE ADJUSTMENT. POSITIVE, DIRECT, TWO -WAY DAMPER CONTROL SHALL BE PROVIDED WITH NO SLEEVES, SPRINGS OR SCREW ADJUSTMENTS TO COME LOOSE AFTER INSTALLATION. SUPPORT CABLE ASSEMBLY TO AVOID BENDS AND KINKS IN CABLE. ROUND OR OVAL DUCTWORK SHALL BE SEMCO, UNITED, WESCO OR EQUAL, SHEETMETAL, WITH SMOOTH INTERIOR SURFACE, WITH LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) ROUND DUCTWORK GAUGES PER THE FOLLOWING TABLE (REFERENCE SMACNA HVAC DUCT CONSTRUCTION STANDARDS FOR GAUGES WHEN PRESSURES EXCEED 2" W.G.): SIZE 14" & UNDER 15" THRU 26" 28" THRU 36" 38" THRU 50" 52" THRU 60" GAUGE 26 24 22 20 18 LINDAB SPIROSAFE, LEWIS & LAMBERT OR APPROVED EQUAL FACTORY - MANUFACTURED ROUND DUCTWORK AND FITTINGS MAY BE SUBSTITUTED FOR SPECIFIED ROUND BRANCH DUCTWORK, AT CONTRACTORS OPTION. HEAVY LIQUID JOINT SEALANT MAY BE OMITTED ON FACTORY - MANUFACTURED ROUND DUCTWORK. LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) FITTINGS 24" IN DIAMETER AND LESS SHALL BE PREFABRICATED, SPOTWELDED AND INTERNALLY SEALED. CONTINUOUSLY WELD FITTINGS LARGER THAN 24" IN DIAMETER. FITTING GAUGE SHALL BE 22 GAUGE FOR 36" FITTINGS AND UNDER, 20 GAUGE FOR LARGER SIZES. 90 DEGREE TEE'S SHALL BE CONICAL TYPE. SEAL LONGITUDINAL AND TRANSVERSE DUCTWORK JOINTS AIRTIGHT WITH HEAVY LIQUID SEALANT APPLIED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. PROVIDE GAUGE THICKNESS IN MEDIUM PRESSURE (DUCT PRESSURE CLASS 3" TO 6" W.G.) DUCTWORK AS RECOMMENDED BY SMACNA. 15A 2 -3 FLEXIBLE DUCT LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" W.G.) AND MEDIUM PRESSURE (DUCT PRESSURE CLASS 2.1" TO 6" W.G.) FLEXIBLE DUCT SHALL BE FLEXMASTER TYPE 8B, THERMAFLEX TYPE G -KM, OR EQUAL (FIRE RETARDANT POLYETHYLENE) PROTECTIVE VAPOR BARRIER, U.L.181 CLASS 1, ACOUSTICAL INSULATED DUCT, 2" (R -6.0) FIBERGLASS INSULATION. PROVIDE CPE LINER WITH STEEL WIRE HELIX MECHANICALLY LOCKED OR PERMANENTLY BONDED TO THE LINER. FLEXIBLE DUCT RUNS SHALL NOT EXCEED 6 FEET IN LENGTH, AND SHALL BE INSTALLED STRAIGHT AS POSSIBLE AVOIDING TIGHT TURNS. INSTALL FLEXIBLE DUCT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. AT A MINIMUM, INSTALL TWO WRAPS OF DUCT TAPE AROUND THE INNER CORE CONNECTION AND A METALLIC OR NON- METALLIC CLAMP OVER THE TAPE AND TWO WRAPS OF DUCT TAPE OR A CLAMP OVER THE OUTER JACKET. DUCT CLAMPS SHALL BE LABELED IN ACCORDANCE WITH UL-181B AND MARKED 131B-C. DUCT TAPE SHALL BE LABELED IN ACCORDANCE WITH UL 181B AND MARKED 181 B -FX. 15A 2 -7 AIR DEVICES PROVIDE AIR DEVICES AS SCHEDULED ON DRAWINGS, MANUFACTURED BY CARNES, E.H. PRICE, KRUEGER, NAILOR INDUSTRIES, TITUS, OR TUTTLE & BAILEY. SELECT AIR DEVICES TO LIMIT ROOM NOISE LEVEL TO NO HIGHER THAN NC -30 UNLESS OTHERWISE SHOWN. PROVIDE DEVICES WITH A SOFT PLASTIC GASKET TO MAKE AN AIRTIGHT SEAL AGAINST THE MOUNTING SURFACE. COORDINATE FINAL LOCATION, FRAME, AND MOUNTING TYPE OF AIR DEVICES WITH ARCHITECTURAL REFLECTED CEILING PLANS. SUBMIT COMPLETE SHOP DRAWINGS INCLUDING INFORMATION ON NOISE LEVEL, PRESSURE DROP, THROW, CFM FOR EACH AIR DEVICE, STYLES, BORDERS, ETC. CLEARLY MARKED WITH SPECIFIED EQUIPMENT NUMBER. SUBMIT SAMPLES OF EACH AIR DEVICE AS REQUESTED BY THE ENGINEER. PROVIDE WALL SUPPLY AIR REGISTERS WITH DOUBLE DEFLECTION BLADES AND OPPOSED BLADE DAMPERS. PROVIDE CEILING SUPPLY AIR REGISTERS OF ALUMINUM TYPE AND WITH THROW PATTERN AS INDICATED ON DRAWINGS. PROVIDE WALL MOUNTED RETURN AIR GRILLES AND EXHAUST AIR REGISTERS WITH HORIZONTAL 35 DEGREE ANGLE VISION -PROOF BARS. PROVIDE CONCEALED FASTENERS FOR WALL MOUNTED REGISTERS AND GRILLES. PROVIDE OPPOSED BLADE DAMPERS FOR SUPPLY AIR REGISTERS UNLESS INDICATED OTHERWISE. 15A 3 HVAC EQUIPMENT 15A 3 -17 ELECTRIC UNIT HEATERS PROVIDE ELECTRIC UNIT HEATERS AS SCHEDULED ON THE DRAWINGS, MANUFACTURED BY INDEECO, MARKEL', BRASCH, RAYWALL OR BERKO, STANDARD TYPE PROPELLER UNIT HEATERS WITH SIDEWALL MOUNTING BRACKETS AND HARDWARE FOR HORIZONTAL AIRFLOW. FURNISH HEATER FAN MOTORS COMPLETE WITH A MANUAL MOTOR STARTER WITH AUTOMATIC THERMAL CUTOUTS SIZED TO THE MOTOR LOAD, DISCONNECT SWITCH, AND OTHER CODE REQUIRED SAFETY DEVICES. PROVIDE REMOTE MOUNTED THERMOSTAT. RECEIVED NOV 2 6 2007 PERMIT CENTER LL O , aAr. 11/1/71(16 w r 0 2 - r 1 r 0 I z 1- w O 2 a r 0 0 1- 0 DRAWING CONTENTS: MECHANICAL SPECIFICATIONS DRAWING NO.: MP3