Loading...
HomeMy WebLinkAboutPermit M07-255 - JC PENNEYJ C PENNEY 1249 SOUTHCENTER MALL M07 -255 doc: IMC -10/06 Parcel No.: 2623049085 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Mechanical: 240,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial City'sof Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1249 SOUTHCENTER MALL TUKW J C PENNEY 1249 SOUTHCENTER MALL , TUKWILA. WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA NICOLE PIPKIN 2325 N AKARD ST , DALLAS TX Contractor: Name: MECHANICAL & CONTROL SRVCS INC Address: 301 PORTER WAY , MILTON WA Contractor License No: MECHACS962BT MECHANICAL PERMIT DESCRIPTION OF WORK: REPLACEMENT OF EXISTING ROOF TOP UNIT FOR NEW ROOF TOP UNIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 214 -446 -0950 Phone: 253 926 -9777 Expiration Date: 02/26/2010 M07 -255 04/30/2008 10/27/2008 Fees Collected: $2,256.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP/1,000,000 BTU.. 0 30-50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -255 Printed: 04 -30 -2008 Permit Center Authorized Signature: constructio doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http.• / /www.ci.tukwila.wa.us Permit Number: MO7 -255 Issue Date: 04/30/2008 Permit Expires On: 10/27/2008 I hereby certify that I have read and x ed this permit and know the same to be true and correct. All provisions of law and ordinance: governing this work will be complied , whether specified herein or not. The grantin• of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatin< performance of work. I am authorized to sign and obtain this mechanical permit. Date: 011 Signature. Date: l 3O - o S Print Name: -- So EL SG-1 Lt PPECgr This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 -255 Printed: 04 -30 -2008 Parcel No.: 2623049085 Address: 1249 SOUTHCENTER MALL TUKW Suite No: Tenant: j C PENNEY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -255 Status: ISSUED Applied Date: 11/27/2007 Issue Date: 04/30/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Do not install manual fire alarm pull stations. 13: If fire alarm horn/strobes are installed, they must be installed throughout the store. 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: Cond -10/06 M07 -255 Printed: 04 -30 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -255 Printed: 04 -30 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: 1 430 — 08 doc: Cond -10/06 Print Name:) EL-- S cH (mot P P M07 -255 Printed: 04 -30 -2008 E -Mail Address: ENGINEER OF RECD CITY OF TUKWILA Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Name: Wale T pk i Mailing Address: 2325 N. k knrd S+ E -Mail Address: nic.D1.. 1 i Okin ya.hov • tom Contact Person: I et ii1 WI I f A I Pr Company Name: I,o( - f E 1/l eer S Mailing Address: 10 ND 11 /' 5 1 * S4 r e S Dkan C Cty Day Telephone: Fax Number: Contact Person: KOJ I tA G. 4I1, A ,,p i S E -Mail Address: r. I b KJ a CttMA.Y1. t rn Q:\Applications\Porns- Applications On Lioe13 -2006 - Permit Application.doc Revised: 9 - 2006 bh — All plans must be wet stamped by Engineer of Recd Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 1� , / King Co Assessor's Tax No.: 2.1.0 - ( Li -909 s Site Address: fZ� cS Vrk Gt2, St`Ct, /t (MISS Suite Number: Floor: .3 Ittk -ts Tenant Name: J C New Tenant: ❑ Yes la. No Property Owners Name: INe.�55 e Mailing Address: 43 Svu4a1eerltleO I' Lw Trik.tw i Imo_ 'CONTACT PERSON who do we contact when your permit is ready to be issue City State Zip Day Telephone: 214 446 056 - kik& 13 7'020 City , /' State Zip Fax Number: 214 • y�V! • hti5 I GENERAL CONTRACTOR INFORMAT (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5 Company Name:' Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State State Zip State Zip Contractor Registration Number: Expiration Date: CHITECT OF RECORD All plans 'mist be wet stamped by Architect bf Recor Company Name: Co I :'SD n /r'' ' � d L __ L Mailing Address: I'1 ZQ Fi fI-h ft VG. "/OC) Su le City Day Telephone: Fax Number:' WA- aA /or WA- Zip Page 1 of 6 tiQr QLis Unit Type: Qty - Unit Type: Qty ` Unit Type: yp . ::Qty : = Boiler/Compressor: ; 0-3 HP /100,000 BTU Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/md MECHANICAL PERMIT INFQ Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ... Fuel Type: Electric..., Gas... Indicate type of mechanical work being installed and the quantity below: Q: Applications\Forms- Applications On Linel3 -2006 - Permit Application.doc Revised 9 -2006 hh MECHANICAL CONTRACTOR INFORMATION Company Name: T Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 2 ()CO (O Scope of Work (please provide detailed information): [ ,e • RA bole h<,u) -TL'L r:u C�1G1 Sf7/1G( Tu Other: Page 4 of 6 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R O / D R AG: Signature: OR A (Gj -� ' Date: !1/27/() cD Print Name: Ai / e P/ pt-// s Mailing Address: , 3 95 4 A� tt f S/ Y.jw Date Application Expires: Date Application Accepted: 1(- - -7 —/7 Q:\Applicatioe Toms- Applications On LineO -2006 - Permit Application.doc Revised: 9 -2006 bb Applicable to all permits in this a Day Telephone: 2# yW ' 'V City State Zip Staff Initials: r , , n Page 6 of 6 i Receipt No.: R08 - 01413 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us Payee: MECHANICAL & CONTROL SERVICES, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 20720 1,811.00 RECEIPT Parcel No.: 2623049085 Permit Number: M07 -255 Address: 1249 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 11/27/2007 Applicant: J C PENNEY Issue Date: Initials: JEM Payment Date: 04/30/2008 08:58 AM User ID: 1165 Balance: $0.00 Account Code Current Pmts 000/322.100 1,811.00 Total: $1,811.00 Payment Amount: $1,811.00 1817 04/30 9711 TOTAL 1811.00 doc: Receipt -06 Printed: 04 -30 -2008 Receipt No.: R07 -02592 Payee: CALLISON ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049085 Permit Number: M07 -255 Address: 1200 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/27/2007 Applicant: J C PENNEY Issue Date: Initials: WER Payment Date: 11/27/2007 02:29 PM User ID: 1655 Balance: $1,811.00 TRANSACTION LIST: Type Method Description Amount Payment Check 208818 445.25 Account Code Current Pmts 000/345.830 445.25 Total: $445.25 Payment Amount: $445.25 5388 11/27 9710 TOTAL 4308.i8 doc: Receipt -06 Printed: 11 -27 -2007 COMMENTS: G ) o tl e. s ht - t — J,e, "- ,(,vri Address: 1 Z L/C( fh (N c fell Date Called: ? 43( VP 00 t g i t (F- / Date Wante : 1 Z 10? / D c2 C m p.m. Requester: Phone No: x.53 - )-,c6- Lic 07 Proje,,cr - Cj c kr FJNil T ype o fJnspection: k- k N. i\t Address: 1 Z L/C( fh (N c fell Date Called: Special Instructions: Date Wante : 1 Z 10? / D c2 C m p.m. Requester: Phone No: x.53 - )-,c6- Lic 07 INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Inspecto : ri $60.00 REINSPECTION EE REQUI p- d at 6300 Southcenter Blvd., Sui I Rece';•t No.: Ma El Corrections required prior to approval. Date: /OZ ED. Pr' r to inspection, fee must be 100. Call to schedule reinspection. 'Date: v�' Project: Type of I peectioq: J t e j i Address: i2-`f SC Date Called: Special Instructions: 02Y? c),5-e)/ - MKT_` e�(� 32 Date Wanted: q (11...m. /O-24 - o p.m. R equester: Phone 4 2._(0— 2171 71 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. (206)431 -3670 Corrections required prior to approval. COMMENTS: oo t/JA , 7f :31 t ,lam , J Inspe:iol! Date: _Z4 -dig $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Projec PCI.) Type o nspection: . lair' h — , ti Qe t �y F Ps -V a PP due0 Address: p7 l Al A(( Date Called: . Special Instructions: Date Wanted: 7 z o ® Cal n: P.M: Requester: 17 e &1,U ► ti 4;rn,, Phone No: X5 3- 307— 36 I COMMENTS: tjr m I-) h -iry - (\?pfwe(0 Qe t �y F Ps -V a PP due0 ,� VAC ?t lurr 00 ( )dt i- ►k,, 25 tttti cc f Lec-tr;o^ I .; r n‘;l 11 /4.3g %Ccr ) e tee-ir 44 ( - -- 1 :7U5P,4e4 iri) Li 0 t>fA iJerTc o or g r A - k . P-P irery - rP < *SS1.ty€ T kt.5p 1 ;11 40N •i frf s E(2r 17 e &1,U ► ti 4;rn,, �I pe r: Date: 7- z ac.. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION PERha NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. VI Corrections required prior to approval. El 6 .00 REINSPECTIO FEE RE IRED. Prior to inspection, fee must be a' at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: 04 -04 -2008 NICOLE PIPKIN 2325 N AKARD ST DALLAS TX 75201 RE: Permit Application No. M07 -255 1249 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 11/27/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 05/25/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 05/25/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, &i xc: ifer Marshall it Technician Permit File No. M07 -255 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Emphasis On Excellence January 4, 2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Jennifer Marshall Dear Ms. Marshall, Respectfully Submitted, Mark Rademaker Mechanical Designer M • Retail Engineering, Inc. Re: Correction Letter #1 — JC Penney 1200 Southcenter Mall — Permit # M07 -255 M- Retail Project #0706010 I am writing this as a response to your correction letter dated December 12, 2007 in reference to the above project. We will not be replacing any rooftop air conditioning units at this time. I hope that this will rectify the deficiencies and allow for the permit process to move forward. Should you require any further information or have additional questions please do not hesitate to contact me at the phone number listed below. I appreciate your help with this matter. Evms 07 / 11 / 09 1259 Kemper Meadow Drive • Forest Park, Ohio 45240 513- 825.1152 • FAX 513.825.4549 • E -MAIL ntretail@m- corporations.com An M•Corporation \ 1- '�CIlY �C TIVFD l� JAN 0 9 2000 PEHMIT CENTER December 12, 2007 Nicole Pipkin 2325NAkardSt Dallas TX 75201 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M07 -255 JC Penney —1200 Southcenter Mall Dear Ms. Pipkin, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, fifer Marshall it Technician xc: File No. M07 -255 City of Tukwila P:\Perrnit Center\Correction Letters \2007%407-255 Correction Ltr #1.DOC Je Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: December 12, 2007 Project Name: J C Penney Permit #: ' M07 -255 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL. NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Scope of work describes the replacement of an existing RTU with a new RTU. Please provide the manufactures specifications. Unit specifications shall identify compliance with the current 2006 Washington State Energy codes. 2. Identify location of new RTU. Details shall identify methods for securing new mechanical units. 3. Provide only those plan sheets that are relative to the mechanical code and remove other unrelated sheets. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. DEPARTMENTS: 08 Bui�d rg Public Works ❑ Complete Comments: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 `'PERMIT COORD COPY -- PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -255 DATE: 01 -09 -08 PROJECT NAME: JC PENNEY SITE ADDRESS: 1200 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) I nco mp lete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ Permit Coordinator DATE: DATE: Planning Division DUE DATE: 01 -15-08 Not Applicable n No further Review Required n DUE DATE: 02 -17 -08 Not Approved (attach comments) 11 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M07 -255 DATE: 11 -27 -07 PROJECT NAME: J C PENNEY SITE ADDRESS: 1200 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Igkol DEPARTMENTS: tyi Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-29-07 Complete TUES/THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Approved Notation: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 511 AV c, /i Fire Prevention Structural ❑ Incomplete Structural Review Required Approved with Conditions Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 1 Fire ❑ Ping ❑ PW ❑ Staff Initials: Planning Division Permit Coordinator Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required C REVIEWER'S INITIALS: DATE: DUE DATE: 12-27-07 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: n City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:• / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I/ 7/00 00 Plan Check/Permit Number: M07 -255 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: JC Penney Project Address: 1200 Southcenter Mall Entered in Permits Plus on iapplications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director SA ; - 9 200 Contact Person: N' (+1) if o n Phone Number: 214. 444 '615 ) Summary of Revision: Sa DEC of a )br k e1(x°S rot I y Ju.4 l/1t re (C rri of TU (.aJ- '-hr's P -� '-h Sheet Number(s): rai e.r D affected EnglneerJ Civreirvndefx6 "Cloud" or highlight all areas of revision including date of r ision Received at the City of Tukwila Permit Center by: ) P ' License Information License MECHACS962BT Licensee Name MECHANICAL & CONTROL SRVCS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602338440 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 301 PORTER WAY Address 2 City MILTON County PIERCE State WA Zip 98354 Phone 2539269777 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 1/30/2004 Expiration Date 2/26 /2010 Suspend Date Separation Date Parent Company Previous License ARASSI *981K0 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date DICKSON, PAUL TREASURER 01/30/2004 Bond Amount GROVER, HAROLD VICE PRESIDENT 01/30/2004 791184C Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #3 DEVELOPERS SURETY & INDEM CO 791184C 02/06/2008 Until Cancelled $12,000.00 02/10/2008 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MECHACS962BT 04/30/2008 MECHANICAL SYMBOLS ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO SCALE. SYMBOL DESCRIPTION PARTIAL MALL LEVEL FLOOR PLAN HVAC M202 DUCT M501 MECHANICAL DETAILS EQUIPMENT NUMBER \ / /,._� AIR DEVICE SUPPLY DIFFUSER 415 RETURN OR EXHAUST GRILLE "x 10" / L1 "x 12" SLOT DIFFUSER 16 - FLEXIBLE DUCT CO CO2 SENSOR 0 THERMOSTAT 0 EMS SENSOR c: HUMIDISTAT 0 STATIC PRESSURE SENSOR Sp SMOKE DETECTOR L L 45' PRESSURE TAP WITH VOLUME DAMPER CONICAL TAP WITH VOLUME DAMPER ►— CONICAL TAP WITHOUT VOLUME DAMPER - ,. MANUAL VOLUME DAMPER MOTORIZED DAMPER M BAROMETRIC DAMPER IN N - FS FIRE /SMOKE DAMPER - -F FIRE DAMPER 101.--... ■— S SMOKE DAMPER CD =— CONDENSATE DRAIN DIRECTION OF SLOPE 4-- DIRECTION OF FLOW GATE VALVE BALL VALVE ---4 - TEMPERATURE AND PRESSURE RELIEF VALVE PLUG VALVE /BALANCING COCK SOLENOID VALVE { -..- CHECK VALVE - LI HYDRAULIC SHOCK ARRESTOR VALVE IN VERTICAL --cry- UNION II E— VACCUUM BREAKER e {I CLEANOUT OR WALL CLEANOUT y THERMOMETER GAS PRESSURE REGULATOR MECHANICAL DRAWING LIST M100 MECHANICAL SCHEDULES M201 PARTIAL MALL LEVEL FLOOR PLAN HVAC M202 PARTIAL UPPER LEVEL FLOOR PLAN HVAC M501 MECHANICAL DETAILS MECHANICAL LEGEND EQUIPMENT MAX. CFM 6 "x 6" MARK (SEE SCHEDULE) RTU "x 6" 235 16 EQUIPMENT NUMBER 310 AIR DEVICE 3 415 No. OF AIR DEVICES "x 10" - . ---,- MARK (SEE SCHEDULE) -.- -CFM L1 "x 12" 350 16 MARK 'B' AND 'F' NECK SIZE MAX. CFM 6 "x 6" 110 12 "x 6" 235 16 "x 6" 310 14 "x 8" 415 16 "x 10" 540 16 "x 12" 710 16 "x 16" 1000 NECK SIZES (U.N.O.) MAX. CFM NECK SIZE 6"0 0 -100 8"0 101 -225 10 "0 226 -400 12 "0 401 -650 14"0 651 -850 16 0 851 -1000 MARK '0' NECK SIZE MAX. CFM 12 "x 12" 350 24 "x 12" 700 24 "x 24" 1400 NOTES: MARK A D 24 "0 24X24 FRAME SIZE MECHANICAL ABBREVIATIONS AC AFF Al AO BF BFC BC CFPB DB DI DO DS EAT EDH EF EMS ABOVE CEILING ABOVE FINISHED FLOOR ANALOG INPUT ANALOG OUTPUT BELOW FLOOR BELOW FINISHED CEILING BELOW GRADE CONSTANT VOLUME FAN POWERED BOX DRY BULB DIGITAL INPUT DIGITAL OUTPUT DISCONNECT SWITCH ENTERING AIR TEMPERATURE ELECTRIC DUCT HEATER EXHAUST FAN ENERGY MANAGEMENT SYSTEM EUH FPB FPI FPM GC GUH LAT MVD N NTS OBD RA SA U.N.Q. VAV WH ELECTRIC UNIT HEATER FAN POWERED BOX FINS PER INCH FEET PER MINUTE GENERAL CONTRACTOR GAS UNIT HEATER LEAVING AIR TEMPERATURE MANUAL VOLUME DAMPER NEW NOT TO SCALE OPPOSED BLADE DAMPER RETURN AIR SUPPLY AIR UNLESS NOTED OTHERWISE VARIABLE AIR VOLUME WATER HEATER OBD NO NO FINISH WHITE WHITE 2. CONTRACTOR TO COORDINATE FRAME STYLE WITH ARCHITECTURAL PLANS. SEE DETAIL 15818/M501 3. 22 "x 22" (U.N.0) THROW 4 -WAY 35 DEGREE FIXED BLADE 4. AIR DEVICE SCHEDULE FUNCTION SUPPLY NON- SUPPLY 5. PATTERN CONTROLLERS. 6. PLENUM WITH FACTORY DUCT LINER. 7. 1" WIDE FRAME. MANUFACTURER /MODEL TITUS TMR 11TUS 350RL 8. DESIGN CRITERIA (PROTOTYPE ONLY) BASED ON ASHRAE HANDBOOK — 2005 FUNDAMENTALS SEATTLE, WA OUTDOOR DESIGN CONDITION 2% COOLING: 82/66 DEGREES F. DB /WB 99% HEATING: 21 DEGREES F. DB INDOOR DESIGN CONDITION SUMMER : 75F DB /50% RH WINTER: 72F DB FILE COPY Permit No. Plan review approval is abject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approve = d Copy and conditions is acknowledged: B Date: NOTE 1 City of Tukwila BUILDING DIVISION NECK SIZE NOTE 3 (U.N.O.) 6E1-'1-IRATE PERMIT REQUIRED FOR: 0 Mechanical p Electrical gej Plumbing at Gas Piping City of Tukwila BUILDING DIVISION NOTES 2,3 2,7,9 co �i Q -Q cv 2 0 0 mow~ ci% W - Q w p Z 0 O LLc) 0 � s a E 0 C 0 0 a ci L 0 o E airInE,: >..� =.K s. / :,, NOV •9 2 2007 z 0 CD J U 0 X 0 0 a) co CO d' d cn TO (N N Cl- 9. EXHAUST GRILLES IN SALON AREA SHALL BE PROVIDED WITH DUCTED BOOT. (ADAPTOR) 10. DIFFUSER FRAME SHALL BE SUITABLE FOR THE TYPE OF CEILING WHERE IT IS MOUNTED, G: 10706xxx1070601010706010 _M100.dwg 11112107 LOCATION LAY -IN CEILING IN SALES AREA EXISTING LAY-IN CEILINGS OR SIDEWALL (ELECT. ROOM) ► CEWEL! NOV 212007 PERMIT CENTER Mop - 255 X1:22:24 PM COPYRIGHT 2007 CALLISON ISSUED / REVISED w LIU 0 I- 0 M DATE PERMIT / PRICING ISSUE 11.09.07 PERMIT ISSUE NOT FOR CONSTRUCTION MECHANICAL SCHEDULES rx.i..�?:SEE.i• _EXIST SUPPLY DIFFUSER :(TYP.) 72tIni2UtfieWireZ,AL 3.:". rmi w ®— A inta '• — . jar :1 N maw RAH SCALE: 1 /a " =1 -0" ate_._ .. _ ....f.' AL VALL LEVEL F HVAC - -OOR P AN KEY NOTES (M201 - M202) CO W (OO Q I 0.. CL' 4y 2 o Q U z W I— W �Q p E 0 U 0 • 65 L � 3 to � N m ¢ to Q CA N N c o pt- co co I O ao ao E w Q; W m � n 0 a O X m e�w NOV 1 2 2007 • ▪ PROVIDE NEW BRANCH SUPPLY AIR DUCTWORK AS SHOWN ON PLAN. MATCH TO SIZE OF EXISTING BRANCH DUCTS. CONTRACTOR TO CONNECT NEW DUCTWORK INTO EXISTING MAIN DUCT TRUNK. FIELD VERIFY EXACT ROUTING AND REQUIREMENTS. 2 EXISTING AIR DEVICE TO REMAIN AS SHOWN. CLEAN AND REPAIR AS REQUIRED. EXISTING AIR DEVICE SHALL BE RELOCATED TO NEW LOCATION SHOWN ON PLANS. CONNECT TO EXISTING DUCT. REBALANCE AS REQUIRED. ® NEW SUPPLY AIR DIFFUSER. CONTRACTOR TO MATCH STYLE WITH EXISTING SUPPLY AIR DIFFUSERS. REBALANCE AIR AS REQUIRED TO DISTRIBUTED EVENLY. O NEW RETURN AIR GRILLE. CONTRACTOR TO MATCH STYLE WITH EXISTING RETURN AIR GRILLES. ® MAINTAIN NEW DUCTWORK AT 18" ABOVE CEILING AS SHOWN. ( ./ \ EXISTING AIR DEVICES AND ASSOCIATED DUCTWORK TO BE REMOVED FROM DEMOLISHED MALL LEVEL FITTING ROOMS. REMOVE DUCTWORK BACK TO MAINS AND CAP. FIELD VERIFY EXACT REQUIREMENTS. ® EXISTING AIR DEVICES AND ASSOCIATED DUCTWORK TO BE REMOVED FROM DEMOLISHED UPPER LEVEL STOCKROOMS AND FITTING ROOM. REMOVE DUCTWORK BACK TO MAINS AND CAP. FIELD VERIFY EXACT REQUIREMENTS. C:: . NOV 2 7 2007 CLN - FER G: 10706xxx10706010 10706010_4201.dwg 11112/07 c1:21:16 PM COPYRIGHT 2007 CALLISON ISSUED / REVISED DATE PERMIT / PRICING ISSUE 11.09.07 PERMIT ISSUE MALL LEVEL HVAC PLAN M201 EXI SUPPLY DIFFU ER (TYP.) CF:1) €v)i ,PART n \M201 SCALE: 1/8 " =1 -0" awn wun MMI — — r - WW — WW — - MM MM MO MM MM - -I MM MUM MM WM — — — — — — — — — — — UPPER LEVEL FLOOH PLAN HVAC •Ti) C.,.._..,, ,_..rte.,. ..,n... W. ;L•V':.ta'.w.,...:a .a.,. mow. , :w«..,. KEY NOTES (M201 - M202) PROVIDE NEW BRANCH SUPPLY AIR DUCTWORK AS SHOWN ON PLAN. - MATCH TO SIZE OF EXISTING BRANCH DUCTS. CONTRACTOR TO CONNECT NEW DUCTWORK INTO EXISTING MAIN DUCT TRUNK. FIELD VERIFY EXACT ROUTING AND REQUIREMENTS. e EXISTING AIR DEVICE TO REMAIN AS SHOWN. CLEAN AND REPAIR AS REQUIRED. EXISTING AIR DEVICE SHALL BE RELOCATED TO NEW LOCATION SHOWN ON PLANS. CONNECT TO EXISTING DUCT. REBALANCE AS REQUIRED. Q NEW SUPPLY AIR DIFFUSER. CONTRACTOR TO MATCH STYLE WITH EXISTING SUPPLY AIR DIFFUSERS. REBALANCE AIR AS REQUIRED TO DISTRIBUTED EVENLY. NEW RETURN AIR GRILLE. CONTRACTOR TO MATCH STYLE WITH EXISTING RETURN AIR GRILLES. 0 MAINTAIN NEW DUCTWORK AT 18" ABOVE CEILING AS SHOWN. 7 EXISTING AIR DEVICES AND ASSOCIATED DUCTWORK TO BE REMOVED FROM DEMOLISHED MALL LEVEL FITTING ROOMS. REMOVE DUCTWORK BACK TO MAINS AND CAP. FIELD VERIFY EXACT REQUIREMENTS. EXISTING AIR DEVICES AND ASSOCIATED DUCTWORK TO BE REMOVED FROM V DEMOLISHED UPPER LEVEL STOCKROOMS AND FITTING ROOM. REMOVE DUCTWORK BACK TO MAINS AND CAP. FIELD VERIFY EXACT REQUIREMENTS. 56 F::1:7'N. axx3.l,:.zr gip; 55 G: I0706xxx 1070601010706010_M201.dwg 11 /12/07 00 } W a CL o N tact C) 0 Z W '- I W O n T - U °nJ Q CO Q LL o co n) • - =1 N P') E 0 0 ai 0 0 0 0.. 9?M hr) 0 • N N m � p g0 0Q g W 0, ';1 E 6 -6 co c a am 0, 0 wC?x LS Nit . 3I . ,. ° Y , , ,, I 02 ,., NOV 1 2 2007 • 2 0 CV lt7 _ LO LO cn CD x CD Q b mNrN C\1 c1:21:38 PM .. 4_.- r L , L) NOV 2 7 2007 CENTER COPYRIGHT 2007 CALLISON CD CO ce °O 00 W F Q o W o a CL cm w N Cf) ISSUED / REVISED DATE PERMIT ISSUE PARTIAL UPPER LEVEL HVAC PLAN M202 PERMIT / PRICING ISSUE 11.09.07 MINIMUM ROUND DUCT TAP METAL GAUGE TAP DIA. (IN.) GAUGE — GALV. STOCK DAMPER GAUGE 8 AND BELOW 24 22 9 — 14 24 22 15 -- 16 22 20 27 — 36 20 18 37 — 50 18 16 FLEXIBLE DUCT (8' —O" MAX RECTANGULAR/ROU ND DUCT TAP FITTING ROUND DUCTWORK `\\ 90 DECREES TEE WITH OVAL TO ROUND TAP OF BRANCH FLOW IS 2/3 OF THRU FLOW) LOCKING REGULATOR EXTENDED FOR INSULATION HANGER SHALL BE AT THE END OF THIS METAL DUCT BRANCH FLEX DUCT TO BE BANDED & T IFFUSER COLLAR SCREWED AND DUCT SEALANT SCREWED AND DUCT S EALANT 15839 ROUND DUCTWORK FITTINGS (06/10/05) = D(1 1/2) (MINIMUM) AL DUCT BRANGI- RIMP 0 90 TEE FITTING 0 45 LATERAL FITTING GALVANIZED DAMPER BLADE (2) GAUGES HEAVIER THAN SUPPLY DUCT. LOSED END BEARING EOPRENE SEALER WASHER (TYPICAL). ROVIDE CONTINUOUS ROD ON DAMPER OVER 12" DIA. DIFFUSER BALANCING DAMPER ROUND DUCT TAP BALANCING DAMPER ATTACH MINIMUM 12" LONG FLAGGING TAPE TO ALL DAMPER HA :LES DUCT CEILING DIFFUSER 15818 B RANCH DUCTS G: 10706xxx1070601010706010 _M501.dwg 11/12/07 c1:22:50 PM NOV 2 7 2007 PE[ Mp 9 CENTER COPYRIGHT 2007 CALLISON Nov 1 2 26 CD CD w 0 > w CL um" U co Z W co 2 a c) 0 o M z W H E" w r O 10 Q o ) CO 0- 2 0 () U E 0 U ai 0 o N) t. . 0 CO t' v o g. v D N N J cx 0003 —c0 E Lu O o (C? (D N OC] qy W Z a p n Q X CO W � .11_ 'V M501 ISSUED / REVISED DATE PERMIT / PRICING ISSUE 11.09.07 PERMIT ISSUE NOT FOR CONSTRUCTION MECHANICAL DETAILS SYMBOL FIXTURE TYPE VOLT MFG. and CATALOG NO. MOUNTING TYPE LAMP TYPE LAMP CODE LAMP QTY. GENERAL LOCATION REMARKS 101 120 277 AS PER SPECIFICATION AND DETAILS RECESSED F028 /835XP /SS /ECO A 3 AS NOTED SEE NOTE 13 SURFACE WALL MOUNTED 101/E 120 277 AS PANDSDETAILSATION ER RECESSED F028 /835XP /SS /ECO A 3 AS NOTED SEE NOTE 8, 13 E FLUSH CEILING MOUNTED 120 120 277 AS PER RECESSED FT4ODL /28W/835/SS/IS B 3 SALES /AS NOTED SEE NOTE 8 ''' E LI 120/E 120 277 AS PER SPECIFICATION AND DETAILS RECESSED FT4ODL /28W/835/SS/IS B 3 SALES /AS NOTED SEE NOTE 8, 13 125 120 277 AS PER SPECIFICATION AND DETAILS PENDANT/ SURFACE CF18DD /E/835 C 4 ENTRY VESTIBULE SEE NOTE 13 II iii • • 128 120 277 AS PER SPECIFICATION AND DETAILS RECESSED CF42DT /E/IN/835 H 1 SALES SEE NOTE 13 I---Q 1 130/4 120 277 AS PANDSDECIF ATION ER SUSPENDED F028 /835XP /SS /ECO A 1 STOCK / AS NOTED SEE 11, 13 130/8 120 277 AS PANDSDETAILSATION SUSPENDED F028 /835XP /SS /ECO A 2 STOCK / AS NOTED SEE 11, 13 1 1-45-1 E 130/8E 120 277 AS PERDSPECIFICATION SUSPENDED F028 /835XP /SS /ECO A 2 STOCK / AS NOTED SEE 11, 13 L 145 148/0 1 20 120 277 AS PER SPECIFICATION AND DETAILS AS PER SPECIFICATION AND DETAILS RECESSED RECESSED CET13DS /835 FT55W/2G11 /835 I J 2 1 SALES / AS NOTED -- SEE NOTE 13 WITHOUT BALLAST 148/1 120 277 AS PANDSDETAILSATION RECESSED FT55W/2G11/835 J 1 -- WITH SINGLE LAMP BALLAST 148/2 ASSY 1 20 277 AS P AND ER SPECIFIC ATION ANDSDETAILSATION RECESSED FT55W/2G11/835 J 1 WITH TWO LAMP BALLAST °,.., 149/0 120 277 AS PER SPECIFICATION AND DERAILS RECESSED FT4ODL /28W/835/SS/IS B 1 SALES / AS NOTED WITHOUT BALLAST. SEE NOTE 8 149/1 277 AS PER SPECIFICATION AND DETAILS RECESSED FT4ODL /28W/835/SS/IS B 1 SALES / AS NOTED WITH SINGLE LAMP BALLAST m 2 149/2 120 277 AS PANDSDETAILSATION RECESSED FT4ODL /28W/835/SS/IS B 1 SALES / AS NOTED WITH TWO LAMP BALLAST. SEE NOTE 8 149/3 120 277 AS PANDSDETAILSATIQN ER RECESSED FT4ODL /28W/835/SS/IS B 1 SALES / AS NOTED WITH THREE LAMP BALLAST. SEE NOTE 8 184 120 277 AS PER SPECIFICATION AND DETAILS YOKE F25 /735SS /ECO K 2 EXTERIOR CANOPY UPLIGHT SEE NOTE 13 300 120 277 AS PER SPECIFICATION AND DETAILS RECESSED MCP39PAR3OLN /U /830 /SP S 2 SALES SEE NOTE 6, 13 i:szi 366 277 AS PER SPECIFICATION AND DETAILS RECESSED MCP100 /U /MED /830 T 1 CANOPY SEE NOTE 15 E 366E 277 AS PER SPECIFICATION AND DETAILS RECESSED MCP 1 P/ID1,�ky(IEIq' lT11830 AND AMID 1/00QODAIJARTZ T 1 1 CANOPY WITH EMEREGENCY QUARTZ LAMP RESTRIKE SEE NOTE 15 I ► 387 120 277 AS PERDSPECI CATION RECESSED MCP39PAR3OLN /U /830 /SP S 1 SALES 470 120 AS PER SPECIFICATION AND DETAILS TRACK MCP39PAR3OLN /U /830 /SP S 1 ESCALATOR INTEGRAL BALLAST FINISH - WHITE SEE NOTE 6 472 277 AS PER SPECIFICATION AND DETAILS SURFACE FOR FIXT. TYPE 470 THRU 474, 47D -- 1 AS NOTED FINISH - WHITE 0 498 277 AS PER SPECIFICATION AND DETAILS UNIVERSAL FURNISHED with FIXTURE -- -- AS REQUIRED L.E.D. DISPLAY LOCATE PER LOCAL CODE REQ'S I _I 3000 -D 120 AS PER SPECIFICATION AND DETAILS PENDANT CF23EL/ MINI TWIST (3000K) N 1 SOLUTIONS CENTER 7' -6" A.F.F. - SEE NOTE 2 SO \ D SYSTLV L-FG - I\ D BACKGROUND SPEAKER FLUSH CEILING MOUNTED S BACKGROUND SPEAKER W /VOLUME CONTROL FLUSH CEILING MOUNTED S VC BACKGROUND SPEAKER SURFACE WALL MOUNTED ® FOREGROUND SPEAKER ( CEILING MOUNTED FOREGROUND SPEAKER WITH VOLUME CONTROL 0 VC CEILING MOUNTED SUBWOOFER FLUSH CEILING MOUNTED VOLUME CONTROL - LIGHT DUTY WALL MOUNTED VOLUME CONTROL - HEAVY DUTY Q H D WALL MOUNTED EXTERIOR SPEAKER ss LIGHTING FIXTURE SCHE3JLE NOT 1. LIGHT FIXTURES AND LAMPS PROVIDED BY JC PENNEY UNLESS NOTED OTHERWISE UNDER REMARKS. 2. THE INDICATED MOUNTING HEIGHT FOR PENDANT /SUSPENDED LIGHTING FIXTURES IS TO THE BOTTOM OF THE FIXTURE FROM FINISHED FLOOR. 3. FIXTURE MOUNTING HEIGHT FOR WALL MOUNTED FIXTURES IS TO THE CENTER OF THE JUNCTION BOX UNLESS NOTED OTHERWISE. 4. ALL STRIP FLUORESCENTS IN EQUIPMENT ROOMS AND STOCK AREAS UNLESS OTHERWISE NOTED, SHALL BE CHAIN SUSPENDED AS SHOWN ON DETAIL ON SHEET E101. 5. THRU FEED WIRING OF STRIP FLUORESCENTS IN THE EQUIPMENT ROOMS AND STOCK AREAS IS NOT PERMITTED. EXCEPT ON LOWER -LEVEL DOUBLE -DECK STOCK. 6. ARROW ON LIGHT FIXTURES INDICATES DIRECTION OF FOCUS, CONTRACTOR TO FOCUS ALL FIXTURES IN DIRECTION AS SHOWN AND 30° VERTICAL, OR AS DIRECTED BY JCPENNEY FIELD REPRESENTATIVE. 7. DESIGN LAMP RATING IS TO BE USED FOR BRANCH CIRCUIT DESIGN UNLESS NOTED OTHERWISE ON PLANS. 8. "E" DENOTES FIXTURE IS PART OF EMERGENCY SYSTEM. CH a5. \G J }\ i J SCHED 9. TRACK IS SUPPLIED WITH MAGNETIC 600W - 120V PRIMARY / 12V SECONDARY TRANSFORMER TO BE MOUNTED ABOVE CEILING. 10. FIXTURE PROVIDED W /(1) 120V PRIMARY /12V SECONDARY 60 VA TRANSFORMER. LOCATE TRANSFORMER IN 4" OCT. J -BOX. 11. MOUNTING HEIGHTS FOR LIGHTS ARE AS FOLLOWS: RECEIVING, VISUAL WORKROOM, & MAINTENANCE WORKROOM - 2' -6" ABOVE SHELF. STOCK SHELVING - 2' -6" ABOVE SHELF AND CENTER OF AISLE. ELECTRICAL ROOMS - 10' -O" A.F.F. DOUBLE-DECK STOCKROOM - MOUNT TO UNDERSIDE OF DECK AND AS HIGH AS POSSIBLE ON UPPER DECK. 12. (4) LOW VOLTAGE 277V PRIMARY /12V SECONDARY 75 VA TRANSFORMERS PROVIDED WITH LIGHT FIXTURES. INSTALL TRANSFORMERS IN J -BOX WITHIN MILLWORK. 13. 120/277 DUAL VOLTAGE BALLAST. 14. FIXTURE IS EQUIPPED WITH INTEGRAL BATTERY BACK -UP. 15. ACCESS TO BALLAST IS THROUGH FIXTURE APERTURE. v S'IV11130 LAMP CODE A B C D F G H J L M N P R S V X Y Z BB E -PRO # 22178 20519 21778 20908 20832 20901 20672 20871 20671 20591 21776 27249 25024 29411 11386 13973 58663 14354 64880 64743 64480 58575 29409 13921 18890 13800 29414 64745 FIXTURE TYPE 101 VOLTAGE WATTAGE 277 72 120 125 128 130/4 277 277 45 25 130/8 145 148/0 277 277 30 0 148/1 148/2 149/0 149/1 149/2 277 277 35 63 149/3 184 300 366 387 470 FLUORESCENT /HID POWER 277 58 277 94 277 76 277 48 277 112 277 277 277 94 48 277 90 277 277 130 45 120 45 ELECTRICAL_ DESIGN NOTES A. DESIGN ENGINEER SHALL VERIFY THIS LIGHTING FIXTURE SCHEDULE IS THE MOST CURRENT AS POSTED ON JC PENNEY'S BUZZSAW SITE, CONTACT JC PLNNLY FON USLH NAML AND NASSWOHU. G:1 0706xxx1070601010706010 _E100.dwg 11112/07 09:34:08 PM 4,0,0 4 C) NOV 2 71007 PERMIT OE.I':! COPYRIGHT 2007 CALLISON 2 0 J J 0 ISSUED / REVISED a, L LI CD cr ? 2 d o 00r� z ° H w J O U L o-) (c, Q E 0 0 C 0 C7� Oo o j �F5)N C) Q) — "4 (V M a- Q ) CO K) PO 0 • c 0 0 N N 0 2 CT 01 QQ cO I U)Ococo 6 • wm ( L i -, w : O Oxm W - N O u : E100 0 N to a) 0) X 0 0 F- (o (0 rr �r ( rte CV CV CI-- LL PERMIT ISSUE ELEGTRIGAL SYMEJULS DATE PERMIT / PRICING ISSUE 11.09.07 POW FR GENERAL WALL OR COLUMN CEILING FLOOR SURFACE FLUSH SURFACE FLUSH SURFACE FLUSH ELECTRICAL PANEL - DISTRIBUTION -- FLUSH CEILING MOUNTED -- -- -- -- -- BACKGROUND SPEAKER - ELECTRICAL PANEL - LIGHTING AND POWER (277/480V) -- SURFACE WALL MOUNTED q -- -- -- -- allir -- ELECTRICAL PANEL - LIGHTING AND POWER (120/208V) -- SUBWOOFER -- -- -- -- -- jag 'MA POINT OF SALE /SIGNAL OUTLET - (RECEPTACLE - EXTENDED) c) AUTOMATIC LIGHT CONTROL REMOTE PANEL -- -- -- -- -- -- - RP -- CONTROL PANEL -- -- -- -- -- -- -- 71 A LL ONTROLERD -- A.T.S. -- Q -- -- -- -- -- ATS NON - CONTROLLED TRANSFORMER -DRY TYPE (480A /120/208Y) -- -- T It NON - CONTROLLED T CL -- RED T FL -- MOTOR (HP AS INDICATED) IVORY -- -- -- -- -- -- DISCONNECT - FUSED -- IG WALL SWITCHES -- -- -- -- -- I h DISCONNECT - UNFUSED -- -- -- -- -- -- C MAGNETIC STARTER -- -- -- -- -- -- COMBINATION STARTER -- -- -- -- -- -- VARIABLE SPEED DRIVE -- -- -- -- -- -- I VSD h LIGHTING CONTACTOR WITH ENCLOSURE -- -- -- -- -- -- = JUNCTION BOX -- 1U s 1-C O s O O s Q RECEPTACLE -- SINGLE, 120V UNLESS NOTED OTHERWISE e e e e RECEPTACLE - DUPLEX, 120V UNLESS NOTED OTHERWISE -- '@ s l 0 s 0 @ s 0 RECEPTACLE - DUPLEX, WEATHERPROOF, 120V UNLESS NOTED OTHERWISE -- 1=0 sP IDQ WP -- -- -- -- 3 DUPLEX RECEPTACLES UNDER 3 GANG COVER PLATE -- s I -- -- -- @ RECEPTACLE - QUADRAPLEX, 120V -- -0,D s -iii "•' S .' '_' s "i" RECEPTACLE - ISOLATED GROUND, 120V UNLESS NOTED OTHERWISE -- s IA@ -- -- RECEPTACLE - SPECIAL PURPOSE - (V, PH, A - AS INDICATED) -- 1 O S s © A S a RECEPTACLE - QUADRAPLEX -- '; : s -::: -- ® A:- s = > ELECTRICAL GROUND -- -- -- -- -- CIRCUIT CONDUCTOR DESIGNATIONS FOR PHASE, NEUTRAL, ISOLATED GROUND AND CIRCUIT EQUIPMENT GROUND CONDUCTORS ARROW DESIGNATES A HOME RUN. DASHED LINE DESIGNATES CONDUITS IN SLAB OR BELOW FLOOR _ -- -- -- SOLID LINE DESIGNATES CONDUITS IN WALL OR ABOVE CEILING ,`-' -- -- -- -- -- -- SWITCH - SINGLE POLE -- $ $ -- -- -- -- SWITCH -- 3 WAY -- $3 $3 -- -- -- -- SWITCH - 4 WAY -- $4 $4 -- -- -- -- SWITCH - DIMMER (SEE SPECIFICATIONS) -- $o $D -- - - -- SWITCH - KEY OPERATED $k $k -- -- SWITCH - MOMENTARY CONTACT -- $MC $MC -- -- SWITCH - WITH PILOT LIGHT -- $P $P -- -- SWITCH - MOTOR RATED -- $M $M -- -- -- -- POWER DISTRIBUTION BOX J -- -- -- -- -- -- ACCENT LIGHTING BRANCH CIRCUIT BOX -- -- -- -- -- -- J DEVICE ON CONTACTOR (EMS LIGHTING CONTROL) * -- -- -- -- -- -- CIRCUIT DISTRIBUTION BOXES (EXISTING) 1 J L - -I -- -- _ -- -- ACCENT LIGHTING BRANCH CIRCUIT BOX (EXISTING) E] -- -- -- -- -- -- SPECIAL- FLOOR OUTLET - TRIPLE WITH IG J -BOX (POWER/P.O.S./TEL) a FLOOR OUTLET - DOUBLE WITH RECPTACLE (POWER /P.O.S.) -- -- -- -- - *0 DEVICE ON EMERGENCY SYSTEM E -- -- -- - -- -- -- - CARPET FLANGE FOR FLOOR BOX C -- -- -- -- -- C I E OOR Dnv FOR INTRUSION DE //� E ACCESS 1 LVVI\ BOX FOR IIYII \UJIVIY ULVItJL /1VLLJU �� (Al �i FLOOR OUTLET - TRIPLE WITH IC RECEPT. (POWER /P.O.S. /TEL.) -- -- -- -- -- -- @I0 FLOOR OUTLET - DOUBLE WITH IG RECEPT. (POWER /P.O.S.) -- -- -- -- -- -- 80 "WALKER" RESOURCE BOX - (CONNECTIONS TO BE NOTED WHEN USED) -- -- -- -- - - - - -^ GROUND FAULT CIRCUIT INTERRUPTER DEVICE GFI -- -- -- -- -- -- HANDICAP AUTOMATIC PUSHPLATE -- -" 1-O _- -- -- -- SOJ \ D SYSTEV LEGS\ D BACKGROUND SPEAKER -- -- FLUSH CEILING MOUNTED - -— S -- i TELEPHONE - WALL MOUNTED BACKGROUND SPEAKER W /VOLUME CONTROL - - BLACK FLUSH CEILING MOUNTED -- S VC SATELLITE DISH /VIDEO STUB -UP LOCATION (DBS) 0 BACKGROUND SPEAKER - -- SURFACE WALL MOUNTED o� FOREGROUND SPEAKER -- ( F- CEILING MOUNTED FOREGROUND SPEAKER WITH VOLUME CONTROL -- 0 VC CEILING MOUNTED SUBWOOFER -- F-ITI s '� FLUSH CEILING MOUNTED -- -- VOLUME CONTROL - LIGHT DUTY POINT OF SALE /SIGNAL OUTLET - (RECEPTACLE - EXTENDED) c) WALL MOUNTED VOLUME CONTROL - HEAVY DUTY -- IQ H D WALL MOUNTED EXTERIOR SPEAKER •, Ss POINT OF SALE /SIGNAL OUTLET - (RECEPTACLE - IN BOX) COV V . \ICATIO\ TELEPHONE -- -- I> - -— COVERPLATE COLOR U.N.O. -- i TELEPHONE - WALL MOUNTED -- - - BLACK -- -- -- -- SATELLITE DISH /VIDEO STUB -UP LOCATION (DBS) 0 -- -- -- -- --- -- BELL -- 8' -2" AFF VERTICAL -- -- -- -- PUSHBUTTON -- F-ITI s '� -- -- -- -- POINT OF SALE /SIGNAL OUTLET - (RECEPTACLE - EXTENDED) -- 6 $ 6 -- -- WHITE 0 •, OFFICE NON - CONTROLLED POINT OF SALE /SIGNAL OUTLET - (RECEPTACLE - IN BOX) -- -- L} -- -- -- 0 DATATREND SIGNAL CABLE OUTLET -- © s A LL ONTROLERD -- -- 0 s Q RECEPTACLE & SWITC— SCH EDJLE LOCATION MOUNTING HEIGHT U.N.O. ORIENTATION U.N.O. RECEPTACLE COLOR U,N.O. COVERPLATE COLOR U.N.O. CONTROLLED/ NON - CONTROLLED COLUMN GENERAL RECEPTACLES 2" AFF HORIZONTAL BLACK BLACK NON - CONTROLLED T -WALL RECEPTACLES 2" AFF HORIZONTAL GRAY BLACK CONTROLLED CORNER FITTING CHAIR AND TABLE 7" AFF VERTICAL GRAY IVORY CONTROLLED CORNER FITTING FLAT SCREEN 8' -2" AFF VERTICAL GRAY IVORY CONTROLLED FITTING ROOM GENERAL 18" AFF VERTICAL IVORY IVORY NON - CONTROLLED PRICE SCANNER (ISOLATED GROUND) 7" AFF VERTICAL ORANGE BLACK NON- CONTROLLED HOLIDAY DECOR./ CEILING OUTLETS CEILING N/A WHITE WHITE CONTROLLED OFFICE NON - CONTROLLED 6" AFF HORIZONTAL WHITE WHITE NON - CONTROLLED OFFICE ISOLATED GROUND 6" AFF HORIZONTAL ORANGE WHITE NON - CONTROLLED A LL ONTROLERD 7" AFF VERTICAL GRAY GRAY CONTROLLED ALL OTHER NON - CONTROLLED 7" AFF WHITE WHITE NON - CONTROLLED ALL ISOLATED OTHE UND 7" AFF -- ORANGE WHITE NON - CONTROLLED EMERGENCY RECEPTACLES 7" AFF VERTICAL RED RED NON - CONTROLLED NON-EM WALL SWITCHES 48" AFF -- IVORY IVORY N/A EMERGENCY WALL SWITCHES 48" AFF RED RED N/A IG WALL SWITCHES 60" AFF -- ORANGE (OR RED) IVORY N/A G - \ERAL EXHAUST FANS FOR TOILET ROOMS AND JANITOR CLOSETS, SHALL BE CONTROLLED BY AUTOMATIC LIGHTING CONTROL SYSTEM. THE EXHAUST FANS SHALL BE SEQUENCED WITH HOUSEKEEPING LIGHTS. 2. FOR POWER OUTLETS, DIMENSION GIVEN IS TO THE CENTER OF OUTLET. 3. ALL 120V SINGLE OR DUPLEX RECEPTACLES SHALL BE RATED AT 300 WATTS EACH UNLESS OTHERWISE INDICATED. CEILING SPEAKERS ARE TO BE INSTALLED USING RAILS OR OTHER MEANS OF ATTACHMENT TO CEILING. A SINGLE 3- COMPARTMENT FLOOR BOX IS REQUIRED FOR A FLOOR FLUSH THREE -GANG DUPLEX OUTLET. 6. A SINGLE 2- COMPARTMENT FLOOR BOX IS REQUIRED FOR A FLOOR FLUSH TWO -GANG DUPLEX OUTLET. 7. OUTLET BOX FLUSH IN WALL /FLOOR WITH 3/4" EMPTY CONDUIT TO ABOVE CEILING. PROVIDE AND INSTALL BLANK COVER PLATE ON OUTLET BOX. 8. PROVIDE POKE -THRU DEVICE FOR DEVICES OTHER THAN SLAB ON GRADE. SWITCHES AND CONTROLS A. WALL B. OTHERS TELEPHONE OUTLETS A. GENERAL WIRI \G D B. SALES AREA COLUMN C. WALL TELEPHONE D. PUBLIC TELEPHONE E. MODEM F. DATA G. OFFICE OUTLETS OUTLET BOXES A. HEADERS B. WALL MOTION SENSOR NOTES: \ OTE S. NOTE: -VI C NOTE: ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE. 1. PROVIDE ADDITIONAL POWERPACKS AS REQUIRED TO PROVIDE A COMPLETE AND OPERATIONAL SYSTEM. 2. PROVIDE ADDITIONAL SENSORS AS REQUIRED TO PROVIDE COMPLETE COVERAGE BASED ON PARTITION, FURNITURE, AND SHELVING PLACEMENT. 3. PROVIDE SENSOR MASKING KITS TO LIMIT COVERAGE AS NECESSARY. 4. COLOR FOR ALL DEVICES SHALL BE WHITE, EXCEPT FOR WALL MOUNTED DEVICES WHICH SHALL BE PER SCHEDULE ABOVE. 5. ALL COMPONENTS LISTED ARE MANUFACTURED BY SENSORSWITCH, INC. PHONE: 1- 800 - 727 -7483 CHAT\ SUSP EL D EVATI Of\ S 48" A.F.F. AS NOTED TYPICAL FOR INDUSTRIAL FLUORESCENTS PROVIDE CHAIN SUPPORT EVERY 4' -0" 7" A.F.F. VERTICAL MID. UNLESS NOTED OTHERWISE 4' -O" A.F.F. VERTICAL MTD. 4' -0" A.F.F. VERTICAL MTD. 4' -O" A.F.F. VERTICAL MID. OR ADA HEIGHT 7" A.F.F. - U.N.O. 8' -O" A.F.F. ON POS /PC BACKBOARD 6" A.F.F. - HORIZONTAL 12" A.F.C. - U.N.O. 7" A.F.F. - U.N.O. 2" A.F.F. - HORIZONTAL ON COVEBASE -TAI .(NOT TO SCALE) 1. THE SUPPORTING OF ANY BUILDING EQUIPMENT OR LIGHT FIXTURES FROM THE UNDERSIDE OF THE ROOF DECKING IS PROHIBITED. E LC K CA S V8OLS sP AL V S VBOLS EL - CTRICAL DRAWI \G LIST E100 ELECTRICAL SCHEDULES E101 ELECTRICAL LEGENDS AND NOTES E301 FLOOR PLAN - GENERAL LIGHTING AND ACCENT E302 LIGHTING E401 FLOOR PLAN - FIRE ALARM, INTRUSION ALARM, AND E402 SOUND & PAGING. E501 ENLARGED PLAN - STORE ENTRANCE POWER E701 ELECTRICAL DETAILS E702 ELECTRICAL DETAILS E703 ELECTRICAL DETAILS E704 ELECTRICAL DETAILS AHA -2 CIRCUIT NUMBER - PANEL SUB NAME PANEL VOLTAGE "H" 277/480V PANEL VOLTAGE "L" 120/208V ELECTRICAL ROOM CIRCJIT D -S G \ATIO\ G: 10706xxx1070601010706010 _E101.dwg 11112107 P R M t1Pp AND RE QUI ' i NOV 2 7 ZUU7 PERMIT CE NI ` EFL c3:49:46 PM COPYRIGHT 2007 CALLISON J1 . 1 L 1 -I-- - 1- 1 1 1 ! I. , 1 I 1 I ! , r. --,-, i ; : 1 i i I 1 1 I 1 - - — ' ! \ V , . 1 1 ` • EX .., f -- T 1 -- F -- r -- 1 --- 1 1 1 I 1 1 1 1 I I I H I I I F I I I I L I 1 1 , 1 I 1 I I 11 III -I- t --I I I I I 1 it I I I I I I I I I — 7 - 1 — - I I I I I I I _ I_ 1 I I 1 I I ,r I I I 1 I [ I I I I I _}._ I I 1 1 1 p "0 1 I F. I I I I I r r -- LI r 1 I', I I I I n I I I / I I I I , / I 1 I 1 l/ 1- -I- - Az- -I-- -- -- t- - --I --Lk -- 1 , ' 1 1 1 1 1 ,/ 1 I I , I I I I / I I f 7 , -/- r - - 1 - - 1 - - V A r - t 1 , I I I, I , I 4 I 1_ ___1 f 1 /1 I I_ 1. 1 1 c i I I I I I I/ I I [• I I I 1 / I, /I F 7 '-r- I-- -[ -.I- I [ I I I I 1 1 1 1 I I I - It 1111 I I I I I coNNLci TO tieifiNG fiCri PANEL; T1 - - - X ,; L: r 1 - ?--V35 4 . ..71r - - "1 I )'.. I I [ I 1 I I 1 — 7 F — 1 I I I I 1 I F.: ) I 1- -k I I -- - ----' -1- - L -1- - '\I --- H I- --1I- - 1 I 1 1 I 1 ' „ I . , , 1 i , , 1 I , I I I I I . \\,1 I I , - 1 - — 1 1 — — — - r - - r t — r - 1 - - - - r \ - 1 - - ' - F . - t ,T, - - t - -[ r - 1 1 L 1 1 I I Th _1 L _1 L IN 0,1 ,c .1 I I I I I , I I ' I I IIIII 1 1 I I I I I I I I , tIIIIIII I I I — -1--- -I I — — -1-- 4 I 1/ — 4 r 1 - 1 1 — i r 1 —1 j r 1 t I 1- - — 4 I-- - — -I-- - I I I I I , 1 I - 1 I T - I I -. --- I T - 1 -- - T -- r - I - -- t - r t — — - t - t - T - I - r [ 1 [,, 1 _ . , 1 1 1 i , 1 1 ,IJI. i I 4 FI, i\I L. I - -I EXI I I f:) I I I I 1 - k iT 11 STING C RUIT <I l 1 t I I 1 .' - ', ' _ ' i 1 A ' — ' --- -1 - , I ONECTTO DISTIG DAN I 1111_1111 I I p, I I I I I I I I i 1 f - 11-1 ag 1-11 [11 17 :1111- ELI ..I- -- -1-1- 1 1 :Nil 11= l irD it' N-r[111°: -- 11-1-T11- 1111 -71 I -I- 1 L-1 —1-1 — l i--1 4: 11 N:°1 -----1-11-1 I\Lir-° —1 ---1-1 I —1 J 1-1—.4-1- I I TY illi t 1--- 41 : I I I [ __ I I II I II I I: _ 1 ----1 r r tir\ : I ' r —j : 111 1: — : IIIII I = 7,_ / kA : (E LII:4---1 : 7+ -1 - - II - rl - - -L_ -1 I I z 1 - - 1 - [ , , - - I - , -- 1 r - T I - I I I I 1 '1' I ,-- --- 0 4 1 Z , I 1 1 1 1 I 1 _1 I I _, i —I I FFLIOC I , 1_ I FILIOCi i iii _ NLO _ I IN II 1 : I ' I 1\ al 1.- / 111111117111 0 I I loHlicti 1 I I ,, 1,/11111111, NEW II li 1 NEW 1' 1 1 1 - I - 1 1 1 1 1 1 1 1H., '1 I I NLbC L L is - I . - t -[\ 1 1 H I ' 1 1 11IIII I I I I. I I I t 4-- I I 11 I I I I 7 f - 7 T 7 - 7 -1- 1 , I '., i): 1. „....1.:1,1 Id ri: r11:,. 'VI 1 1 , ::' t',i.17, I: '',,, I I I II II I I I I 1 1 1 ft : ft I I I 1 1 1 - F--- -1- - - 1-- -+ 1- -+ - 1- --1- - 1 1 1 I I I 1 1 1 I 1 1 1 1 I 1 1 I I I 1 T - - 1 - --[ -- T 7 - -- - r - - 1 --- - - I - - 1 1 - - I - - r TYITICAL, I I I I I I I I , I I. J_ L _1 _ L 1_ __1 I J I I I I ,, 'I I I I JUNE IRS . .. I 1 11 N‘4.1 I I ,e"..,, -1- --[ -4 I- -I-- -1- I I 1 , I 1 I I 1 I I / I II 1 1 [[ II T — T T ,-' T - TT - - -- t II II II 1 :1 I I I I I I '1 , I I I i I II , II II I I -T -I- — — -H -I- — --.: -I-- - - 4 I— -H 4 L — -I-- 4 — I I , I I I I I , I II 1 II 1 I I I I I I I I I L _I _ _I_ _ i L ___L L _1 1 ":,1•1 .:.:,;',,,, I 1, I ' 6oNtlIEci Tol EAST11 EM ' A ' N ' L. -1 rk ' ''''' 1:f A7 IT ' '4.!' -' 2-11 '''''"- 1 I 1 1 1 11111 ON ECIT T EXISTING 'FANO._ - --1-- 1- -41- - H- -1-- — -1- -4 -I -1- I - - 4 - I I 1 1 I I I I MO I IA EMI VE I NLbONL NI: C ..=... Nal ,,„... LW' M.1 I Ei '1 I I I I I I ...........,-......„,m. ....ri7.7 7 7. J.17 11.71 — 1 — -1- - : lier r nkoc l 1, LOC 1 -4:s I I _It_ _. . I .. I I I FT i.TFTrJT1 - I I - T - -- 1 - 1 - H 1 ' 1 I I 1 1 1 H 1 1 1 HH I I 1 . - I [ I--- 1 - 1H I 1 I I , 1 IIIIII 1 ' IILII 1 - 1 I I I 1 I I I 1 I I I I I I 1 I 1 - -1- -4 - ;I- -t -- I- I -4 - I- 4 -[ ' I -I- 4 -- - I- - - - -I- - 1 z - .1 7 i I- r 1 I - , , T7 - 1 ---- F - r, -- IT - - 1 - I , oc 1 NLOCI [II LOC I I I I Ex F I Lxs r 1 , I 1 _., s _ , L A ',---r- i, -,.(_ ----L-- CONE0T TR gISFINu 1 - L i I Le 0 T 0 i ... EVEL LOOP PLA\ E301 SCALE: 1 /8"=1 '--O" GENERAL & ACCENT LIGHTING • • - 1 • 1 1 1 I 1 _ - - t - t I L I 1 1 1 E I 'rid, 1 , - r if - - coNNEOT To XISTIG PA I I I I' I NLO( N LO(t RESSES 7 p PT7IfPT -1-- -4 1 - -I- - 1 rI 7 1 I? [ " Ar."4.:i.L"..==„:=:. I I I I 1 1 I I I I 11111/ 1/1,, LF +- t . [ I -I I I I I HI I I I T 1 1 I [ I 1 1 I 1 1 1 I - - -I- - - - I I I I I rr — I I I I I I _I. _L._ __1 1_ 1_ _1 I I I I I I I I I I I - - - - - I 1 1 . - I - 1 - 1 - F 0 1 L I f• — 1 I I I I I ' I II II 7 7 -1- 6(sTETSlEsiEsi I I 1 1 1 - ft=-1 - =1 1 i-E-;‹1T I F EXSIt i EL I I I 1.2 1.. 1 I I 7 7 A. ALL CEILING MOUNTED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE ARCHITECTURAL REFLECTIVE CEILING PLANS. IF A LOCATION FOR AN ITEM IS NOT SHOWN ON THE ARCHITECTURAL REFLECTIVE CEILING PLANS, VERIFY THE EXACT LOCATION OF THE ITEM WITH THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. THESE REQUIREMENTS APPLY TO ALL CEILINGS TYPES IN ALL AREAS. B. REFER TO ARCHITECTURAL, STRUCTURAL AND MECHANICAL DRAWINGS FOR GUIDANCE AND VERIFICATION OF DIMENSIONS, CEILING HEIGHTS, DOOR SWINGS, ROOM FINISHES AND LOCATION OF DUCTWORK, PIPES, STRUCTURAL STELL, EQUIPMENT, CABINET WORK AND FURNITURE, C. INSTALL WALL LIGHTING FIXTURES, WALL SWITCHES, WALL OUTLETS AND OTHER WALL MOUNTED EQUIPMENT IN STRICT COORDINATION WITH DETAILS, SECTIONS, ELEVATIONS AND ROOM FINISHES SHOWN ON ARCHITECTURAL DRAWINGS. D. FOR LIGHTING FIXTURES LOCATED IN GYPBOARD CEILINGS, CONFIRM LOCATION WITH JCP REPRESENTATIVE PRIOR TO INSTALLATION. E. PROVIDE AND INSTALL OCCUPANCY SENSORS IN FITTING ROOMS, STOCK ROOMS, TOILET ROOMS AND THE OFFICE AREA UNLESS OTHERWISE NOTEDED. OCCUPANCY SENSORS SHALL BE SENSORSWITCH INC. (PH: 800-727-7483). COORDINATE LOCATIONS AND INSTALLATION REQUIREMENTS WITH MANUFACTURER'S REPRESENTATIVE. FIXTURES ON EMERGENCY POWER SHALL NOT BE CONTROLLED VIA MOTION SENSOR. F. ALL STORE LIGHTING, EXCEPT FOR FIXTURES ON EMERGENCY POWER, SHALL BE CONTROLLED VIA MOTORIZED CIRCUIT BREAKERS AND LIGHTING CONTROL MODULE IN UNITIZED SWITCHGEAR. CONTROL FUNCTIONS ' THROUGH 'F5' SHALL BE ASSIGNED TO CIRCUIT BREAKERS VIA PROGRAMMING AT CONTROL MODULE USING INPUT SIGNAL FROM EMS PANEL. G. ALL LIGHTING CIRCUITS IN OFFICE AREA SHALL BE CONTROLLED VIA OCCUPANCY SENSORS ONLY H. ONCE INSTALLED, THE ELECTRICAL CONTRACTOR IS TO EXTEND THE TYPE 300 FIXTURES OUT OF THE HOUSING AND AIM - FFIEM AT i\ DEG FREE ANGLE: IN THE DIRECTION THAT THE ARROW INDICATES. K. 7 - 1, f'v'= 7 n r I I I L [ 7.1 r T I 1 1E71 EI'4.] I I I __[ _ ----- - ----- 1 1 1 1- 1 1 1 • _ 1___ J__ 1 - I - - - 1 I 1 1 I I 1 I I I _ 7:vriLL,.r. - - 4- Li' . rm; - 1 1 - F H Exr EX - .. _ I - T ;•-s- - r FL rH H • F • -- 7 - 1 cc) L L2= ! . L E XS I , GENERAL NOTES ONCE INSTALLED, IT IS THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO AIM THE TYPE 387 LIGHT FIXTURES AT THE CENTERLINE OF THE JEWELRY CASE AT A POINT 6 INCHES IN FROM THE CUSTOMER SIDE. J. ONE POWER PACK IS NEEDED PER CIRCUIT /ZONE TO BE CONTROLLED BY LOW VOLTAGE SENSORS. PLEASE RECHECK COUNTS TO VERIFY THE NUMBER OF POWER PACKS NEEDED TO MAKE A COMPLETE SYSTEM. ADDITIONAL SENSORS MAY BE REQUIRED TO PROVIDE COMPLETE COVERAGE DEPENDING ON PARTITION, FURNITURE, AND SHELVING PLACEMENT L. SENSOR MASKING KITS MAY BE REQUIRED TO LIMIT COVERAGE DEPENDING ON YOUR REQUIREMENTS. KEY NOTES 1 L X 1 I lix LJUi LE 'E x - EXISTING 2X4 LIGHT FIXTURES TO REMAIN. K -) REMOVE ALL POWER AND TELE/DATA CONDUIT AND WIRING ASSOCIATED WITH CASH WRAP. CONDUIT AND WIRING SHALL BE REMOVED TO FIRST J-BOX LOCATED ABOVE CEILING AND MARKED AS SPARE FOR REUSE IN FUTURE RENOVATION. R\ REMOVE EXISTING PANELS AND RECONNECT AS SHOWN. VL/ FIELD VERIFY EXACT LOCATION AND CONNECTIONS PRIOR TO RELOCATING. i CD • meir=w,Lims., RECTVED NOV 2 7 2007 PLEMI CENTER 1r" rsIX:zPi:?-itS 07 NOV i 2 2007 co ( 78 z < E 2 O O 1 1 52. O 0 >- <>< Z 0 F z w 0 Lo OS E301 6 cz 0 ui • CO • • CZ in re) r`.. ° Ct . CI e 1) � PO 2 0 a) o c\ I cn:E co co 2 E -° 0075E E 14 LAI 21) w ( lc — Tk 6 r — 49„, ED co 0 0 x PERMIT ISSUE LOWER LEVEL FLOOR PLAN GENERAL & ACCENT LIGHTING G:10706xxx1070601010706010 E301-E302.dwq 11/12107 0:45:50 PM COPYRIGHT 2007 CALLISON ISSUED/REWSED DATE PERMIT/PRICING ISSUE 11.09.07 1 E302 PEER LLVFL LOOH PLAN SCALE: 1/8 " =1 -a GENERAL & ACCENT LIGHTING AA9 H. K. GENERAL NOTES A. ALL CEILING MOUNTED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE ARCHITECTURAL REFLECTIVE CEILING PLANS. IF A LOCATION FOR AN ITEM IS NOT SHOWN ON THE ARCHITECTURAL REFLECTIVE CEILING PLANS, VERIFY THE EXACT LOCATION OF THE ITEM WITH THE ARCHITECT /ENGINEER PRIOR TO INSTALLATION. THESE REQUIREMENTS APPLY TO ALL CEILINGS TYPES IN ALL AREAS. B. REFER TO ARCHITECTURAL, STRUCTURAL AND MECHANICAL DRAWINGS FOR GUIDANCE AND VERIFICATION OF DIMENSIONS, CEILING HEIGHTS, DOOR SWINGS, ROOM FINISHES AND LOCATION OF DUCTWORK, PIPES, STRUCTURAL STELL, EQUIPMENT, CABINET WORK AND FURNITURE. C. INSTALL WALL LIGHTING FIXTURES, WALL SWITCHES, WALL OUTLETS AND OTHER WALL MOUNTED EQUIPMENT IN STRICT COORDINATION WITH DETAILS, SECTIONS, ELEVATIONS AND ROOM FINISHES SHOWN ON ARCHITECTURAL DRAWINGS. D. FOR LIGHTING FIXTURES LOCATED IN GYPBOARD CEILINGS, CONFIRM LOCATION WITH JCP REPRESENTATIVE PRIOR TO INSTALLATION. E. PROVIDE AND INSTALL OCCUPANCY SENSORS IN FITTING ROOMS, STOCK ROOMS, TOILET ROOMS AND THE OFFICE AREA UNLESS OTHERWISE NOTEDED. OCCUPANCY SENSORS SHALL BE SENSORSWITCH INC. (PH: 800- 727 - 7483). COORDINATE LOCATIONS AND INSTALLATION REQUIREMENTS WITH MANUFACTURER'S REPRESENTATIVE. FIXTURES ON EMERGENCY POWER SHALL NOT BE CONTROLLED VIA MOTION SENSOR. F. ALL STORE LIGHTING, EXCEPT FOR FIXTURES ON EMERGENCY POWER, SHALL BE CONTROLLED VIA MOTORIZED CIRCUIT BREAKERS AND LIGHTING CONTROL MODULE IN UNITIZED SWITCHGEAR. CONTROL FUNCTIONS 'F1' THROUGH 'F5' SHALL BE ASSIGNED TO CIRCUIT BREAKERS VIA PROGRAMMING AT CONTROL MODULE USING INPUT SIGNAL FROM EMS PANEL. G. ALL LIGHTING CIRCUITS IN OFFICE AREA SHALL BE CONTROLLED VIA OCCUPANCY SENSORS ONLY ONCE INSTALLED, THE ELECTRICAL CONTRACTOR IS TO EXTEND THE TYPE 300 FIXTURES OUT OF THE HOUSING AND AIM THEM AT A 30 DEGREE ANGLE IN THE DIRECTION THAT THE ARROW INDICATES. ONCE INSTALLED, IT IS THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO AIM THE TYPE 387 LIGHT FIXTURES AT THE CENTERLINE OF THE JEWELRY CASE AT A POINT 6 INCHES IN FROM THE CUSTOMER SIDE. J. ONE POWER PACK IS NEEDED PER CIRCUIT /ZONE TO BE CONTROLLED BY LOW VOLTAGE SENSORS. PLEASE RECHECK COUNTS TO VERIFY THE NUMBER OF POWER PACKS NEEDED TO MAKE A COMPLETE SYSTEM. ADDITIONAL SENSORS MAY BE REQUIRED TO PROVIDE COMPLETE COVERAGE DEPENDING ON PARTITION, FURNITURE, AND SHELVING PLACEMENT L. SENSOR MASKING KITS MAY BE REQUIRED TO LIMIT COVERAGE DEPENDING ON YOUR REQUIREMENTS. KEY NOTES 0 EXISTING 2X4 LIGHT FIXTURES TO REMAIN. /:\ REMOVE ALL POWER AND TELE /DATA CONDUIT AND WIRING / ASSOCIATED WITH CASH WRAP. CONDUIT AND WIRING SHALL BE REMOVED TO FIRST J —BOX LOCATED ABOVE CEILING AND MARKED AS SPARE FOR REUSE IN FUTURE RENOVATION. 3 REMOVE EXISTING PANELS AND RECONNECT AS SHOWN. 3 FIELD VERIFY EXACT LOCATION AND CONNECTIONS PRIOR TO RELOCATING. G: 10706xxx1070601010706010 _E301- E302.dwg 11/12/07 NOV 21 2007 PFRMFF CLN"T1, c3:45:19 PM COPYRIGHT 2007 CALLISON 1 1,,L___, _ _ y_ ; / ✓/ 1 r „ w 1. n 1 1 11 _ Y 1' V rI t'\ VIL. rte +.)%. / r∎I L...) h � ro I � I T i 1 L. _ .1 � In 1 I �' - I- -1 > , - ( i 1 1 1 l f I I 1 1 1 11 I I I I I ' 1 =: -I--= - ...-1 _L.- —1 L T--- 1=- 1= -rIT _ , ' 1 r f LX 1 1 rw _._.._ _, J, L i l 1 1 l l i 1 1 l I T 1 1 I r - 1 1 1 i � _> -2 ='H 1 1 1 1 1 r I l 1 l 1 1 1 1 1 ! I I I I 1 1 I 1 1 1 I I I I I I I ' I I 1 1 IJ - I I . I- -.L .I _. . 1 _ _ . I _ L l _ JL.._ l - I ) -� --I- _ 1 - - V - _ I I i �I, i I (; I I .. _.._. :. ,.,.. , , -...-47/_7 ., ,_ ;.__ ; J'a,. l�, _ > �, I,,,1 / .._ 1: J` %} L _- .., /,d,'/.4z71'.2../ - 1 1 1 1 1 1 1 ... _ -. _ I 1 I G i. I - . ... -. ',: ,,1' 1 " fl xs r 1� 1" - 1 :. I r I I ( I TT TI - -_r I L\ 1 1 1 1 1 1- I- 1 1 1 1 1 I - - 1 I I 1 TT I I I �� I 1 1 1 L I' I L I L 1 1 I I I l T 1 1 1 1 1 1 1 I I Lt_._.. -I L.__. _.._ -- - -,_ -.._ I- 1,— J h- . _ I �.. I � L � 'I • r!..._ ( r , ,., � I, . (Fi , ,;. „ , .: .._I_ -1 - I I l l 1 G r -_., . =_..,' j... f / r � 1 . I f I i �. � � '� �� i I doNNECit Td E XISTING dIRCIJIT. _.__ _ .._ _ 1 I- I rk i - i - 1 !- - - - I I - r 1 ; I I, I I 1 I 1 1 1 1 i = - - - J L _I _-_ I - _L L 1 - - i I I ! I - - 1_ I I - -� - I I I I - -I - - I I -� - I - I I - -1- -- 1 I - —� — —1— - i a EXS I EXS T I I EXS T I ' EXSTI I EXST IEXSTI 1 r r ..._ <. f ..,l " -. �_<_:.,_I! _._ .- ... r_�- . / T_/ !. �. <...I .. � . .. . _. � /. '_ : ,'_ I I ;� 1 i I L I I F i I I 1 _ ' ..� . �' - � T .:'_i 1 :f 1 r- .-, : �r 1 � ._ ._ _.._ -�- . -:'... _ _.�- v:"'.:.�., ,, f I _._ __R •' •.' . _. _ . _ __ -mss -_ - _ °.- _� _ --`*!. r I I• .__ _..�, � � _ - _ I is cal :r ;, ; T f F f 1 I I I, r J r 1 T 'L ._. _._ I _ _.. - 1 __- _C_ -___ 1 .. _. II( r 1 1 -{ - X T - l__- .- ._l._ , I ;-- -__-r. .. .- � i - J1 • ' L ___.. _. l I . _- _ -._ _ _ .. >:_____ -, r _ _ __ ___ ..__ __ _ ._ __ � f1 I I r �- I r � I I l I - r r X,T - _ � - -- -r- --- 1 I I 1 1 - r rt L_ __ 1., 1 1 1 1 I� � .uaT. ; : I � �� I 1 - � 1 1 J ; I -_ - -- -r _ - -r- I I -r - I _ I 5z�:", - --- --I - fXS - t"X° - -�' -r - �; � E RSC - EXS - EXS 'r , - a o CST - f I � _ _ i 1 I. _ " I 1 O NNEC7 r i - 1 1- I �.; I - . J -- - T I— .---- I � I l I I I , 1F I I I � T I r __ 1 1 I 1 r 1 xw Ft., "� . i ii L- r 1 r � , �. _ - � P , 1 1 I I . . I I 1 r\ I ... .. I .: �, I i I - -p__- I I I 1 - - -� 1 1 1 1EXST a Q � _ . � : EX I; L T- _ _ - _ - - -_. � -. �-� - ', o _, ...s,w, �.�1�_ _...I__ 1 I I 1 r- -r - -1 I 1 I NE I T C I , • $TI G IRC '. o IT. � �.. , oc� I 1 1 I 1 1 U, J I r I f I 1 1 II I, I 1 41 w _ T i L T ;� I I ® o MI. I l T 1 L T T T T I r I I � I__ -r % I I I f ' f I I I I I _ � ,_,_ : I: I r r _f L I �, • : - E I I wv -_. ., �� :;_�'z:�� Pd- I T I I I I ::ir� I I - 1 I L+ �1, 1a..a..=.' I - I - LL " - �. I I I I E'.:�- :L"�': 2r�i.:'.�'_ I! 1 I r - - - 1 . 25 :_., » ._:, � I I -I I _ I Cs^Yr:+- exwM�..t.�Ah+: I F -*":; - I -- S ".J - - -1 I , ._1. . f�X4hx1uY�. I I -'- -I-� - Ti � - ;:�`,.« I - I � - ,., ! - T T T � . �.� I I I 1 I 1 - J . T , .�.,s r :, .�.3�.�.�5 - .�.a I I I I- -1 , ,x - I.Inrin,.n � . W ,. .., F . � l �, e z< r � . ocivF � ,�� a.� " -.�. I I I I I I I f L _ l IL I_ 1- I oc, I I _., ,�»��.� - - II _ lw...o ,�� 1- ;� �. I I I - 1 I - r-- -L I I 1 1 I I I -1 - I- _- �. I I- -_r-1- w�- ...��__ I' I I - 1 1- ..:1- -1- I I -r - - r, . , . >.r &__:..�.�.4�,�� I I I- I- - I -r - �,.� I -L ��. I ---1- - --1-' - - _ ���.,�..� I _L - I _ _ ... ,ten. yx �a ..� . I I I _ 1 -- _ _- I 1 1 ,. � - ,_ . , . ..�a.,ex;:v.tT I ' I +H ; I T i 1� I 1 11 TJ_L - - T : r..,. ,:.. ,. .. to � - r L L_T_ -1-.1-_ _ tix- I I I I I 1 1 I .... 6i:'E(s"w - rr n , n �a u,L«w7.�.+.ua:.5 w_ it , , I I { H r -- -� 1 I i; 1 i � =Pi' I. EXIST I EXS r E�S I SST EX r E7r — 1 Ia I"I L ? 1 1 1 I 1 I I I I I I I I I 1 1 I I I I I I I 1 1 1 I I 1 1 I I I I 1 1 I 1 - I- + - - I l I 1 1 I 1 -� I 1 1 - _1- - I_. ._.. �S -J __fl 1 .;. I- t r - . -- _I- I . -_. l I _ -_ I I , L � I -- 1 1 w -1i I 1 1 I (r)F1 I- x i - I- - - -- - I- -L � I - --I I i 1- -I- - - I- - T � 1 � I I L - I1 - - - - -.,, 1 I I, 1 I: I _ 1 ,. - -► - I - t - - � 1 I I C I •_.1 1 I - - - - 1 - - �- I I I I -�L -i - r- T -i I i l I 1 1 -1- + --i - 1 I 1 1 1 -I- -I -1- I I I 1 1 1 T -I 1 1 1 L-- f- r- I I I I 1 1 I I I I 1 ,' J±h - 1 � T : , 1 1 1 !I I (- .; f - T I J% I I — � � 1 1 1 1 1 1 I T T _, � -- -, .. '; I I_ 1 r_ — 1 L �- 1 L--ht i - 1 I - I- -I- - e- , - -I - - - T- - __ I �1F�Ri 1 L_ I y J — I- � _r- ,i� - - I - I_ 1 �-_ I T -- 1 _r _ _ - _ r - I ( r- - - I- -- I- ___ �... - �._ = .... - l ■ l ,r I I J' i I I 1 1 +, 1' k---T r-= „,1 -f 1 -',-= -r -� � -' - - - -- _. __._._. a I I -' I I - I I 1 - I- _i- I--- _ -- __ _ t -I _ -. - I I 1 -L-- I I _ -._ .. ...... I r-1- - -- .... V, �I� ,/ .._ __ r T T f 1 1 1 I_LT_ I I I -- i I( H 1 -I -LTJ 1 1 I I I -_ I Ti I I I LJ I I __ I - I I L I T_ I _ ..__ r 11 I I _1-_LJ- 1 1 I - -I-_ ____ � 1 - I- ..- I I I - I- I-- I _.._. -.�.. _ � _. I I r -I--I -.. rh i I I ��_. _ .__..... I - - �- I _ _�- - I I -!- 1 17 -� -_ 1 1 1 1 -I- -I � ' -� -- . �_ .._ .._ I I L r 1 1 TTT I I- t --- I - - ��� � w- �� K 1 `` I EX�I” � EXIT 1 �- -� - ± .T 1 I t Y X +J T L ff\LT t TL - - -r - € I 1 �I 1 III a J I( r - _ ' .':. - _ „ _J -- ..i C I , r - , r -� r _ I µ, 1 � Li . �� - -: r : I I - �-- I - - - I � . \_____. _�- _r_ ' ( - L- - I I I - - -. _ - .. - -. I I 1 r - -I -F- - -' - -- _... -_ 1 1 _ I _.. - �. I 1- _.. T- I - __: - I- - _ I- __ - -- T - 1 -_ J r I I I i a - Ji , , " 1 1 �T� I 1 1 i 1 rT - �r- - r 1- f fi - - 1 TT 1 1 I TT I .,r `T F I I i/_______ 1 . L ... _. -I -_... _.. 1 1 I 4,, 1 1 1 . _- I 1 I __.. -_ I ', ' r -. � ;r � T , � - r __. I J., t , A , L_... I r I I T - I __ _ ____._._ - �., L- I- , 1 r 1 1_ L-1 — 1, 'I ._ 1, r , - I r _ 1- LTIJ 1 1 1 -I- I - -_ ._I I 11 T I - I T - 1 - T t __- _.- - -.._. __ J -L _' -LTJ 1 } T -I I -.. _ -r I L- -I--- 1 1 1 I _ I -' J - -_I- r L L - -I- I L __._..- I I 1 -I--L- __I -__- r 1. 1 ---I -- ----1 -1- .._._ , 1 1 - H -I- _ - I- -}. - I L- L J - 1 I � �_� -_ _�_ - _-- 1 :_ - 1 - � 1 -- �I - I - �-1-- - ; � ; --, r 1 1 1 1 I 1 1 1 1 1 1 1 1 I I 1 I I 1 1 1 11 1 1 I - I I I 1 1 ' 1 1 1 i 1 1 t I 1 I 1 1 ; 1 1 1 4 I- -I- -- - -1- -1- -1 -1- 1 I -1- - . 1 -I- - -H,--f---H! -'f-- 1 I , I I ', 1 - -1-- 1�,I I I I r -- _r I 1 r- - - - I -__ I r- _ - I 1 I I �:_,_ E Ir r I � , ,I, _. - . r l r- _ - I 1 I - _ I - % I�/ I I I � I,,:r I �'; , 1 1 I �, y ,, i 1 I 1... I __ 1 1 1 1 I 1 1 1 1 I -L - I 1 r- - - I - I r I" _ - r - �- - I -1- _r - i r- +1 I -r- l- 11 1 1 I I 1 1 I I - , r J% I 1 `1 + : 1- H I I I I I 1, : - -r- -1- + -I =1- -I- - = r _ i 1 1 1 1 I ; I I I I i I - _ - I _ 1 1 1 I I 1 - - 1 I _ I _ - - I I I 1 -- - - I- -r - - r- I I I I I T - - {-- 1 1 -1 -f-L 1� In � 1 1 11 - I- -I 1 1 1 1 - 1 -'- 1 -- _ ; :;1. - l - I 1 I �� 1 _L_I__L.._LJ_ XST _ — - - T J - -- r I — T r EX T L- f.- .._ {- L J - _ 1� r!, I I 1- J 1 r I 1 I- -r- I 1 � 1- 1 r - H-J- -I Y"`' 1 I 1 1 I - I I 1 1 E s t E S[ FIST EXST ---I -L -I-- T 11 _TJ 1 1 T ._ -- I= 1 1 1 1 - - - 1 I I-- I 1 1 - -I -1- - - 1 I - !- 1 I - 11 I I - I-- 1 1 I - 1 I -I- - - 1 1 � 1 I I I- I-- 1 1 1 1 - 1 - I -_ r - I _ =-I- 1 I -- -I- --- 1 1 I 1 1 i" i. _ I- I- IL 1 1 1 1 -L ' �a . + 1 T _I r_ 1 ,y i I� 1 1 1 J . L ,. 1 I' I I J n �, , I � J , 1 I 1 1 1 I L_ _L'J_L-_ 1 - I I 1 1 1 1 1 1 1 _- :, P I I 1 -L 1 =: 1 1 1 1 lu_Lr T 1 1 1 1 1 _LJ 1 1 1 1 1 1 I 1 L- -- 1 1 -�-- I 1 1 1 I I 11 1 1 I-- 1 -I- 1 1 1 1 -I 1 1 - 1 1 1 I I 1 1 I I 1 1 1 1 -I- I - -I- 1 1 1 1 1 i 1 1 r __ l L_- — +_ -L 1 1 I I -I- 1 1 I I 1 1 1 1 1 ; 1 -1 11 1 J f -1 1 I ' - I- I--- -I-�I ---1 — 1-- 1 1 1 1 1 1 1 -H-I-- - FfANBL. —' ' ;....._ -- -- I _ 1_h-1-_ , ,I I l — I — 'I— -I' _ _. _ .. _ - .__ I L I; I - I --- 1 - -r 1 1 I F XSTrXST FT-1-H- I 1 1 1 _ _ I— I -I _1--1 I I--1 -- - P- I I I I I Ex:�r - I I � I - - - .. . _ ,I7 T__ . 1 1 - I---I--1 -I- - 1 1 1 I--r -l-h-�_- I -1--r- - 1 I--r- 1 - a 1 1 1 - --r_ I 1 - - XSTXXJiST _ 1 1 1 1 1 1 - - __ __ - h - r - 1 - -1 --1- NH- I- -I -1-- 1 1 11 1 1 1 l, 1 1 1 1 1 1 Lt - I 1 1 ,�� CX� !_ 1 f _. i__ i r I 1 1 11 I -I— —. . _ _ .. - I: I ! ' , l I _ — I 1 1 I I I r r —1 — — �J .. 1 . I/I I Ex�r .171 _ _.1 �' - EX r 17! ' r :' w - ! : - 1 I T I 1 — — _ h �' 1 � ;, 1 .,, r — . : .r. , , .... •( ' — . �,.l — ' i ,` 1 ;1 -: E ON ___, [CT ... TO - 1 EX1STIN �M CI C CONNC TFN UIT: r"--- _ � 1 O —EX I T __. -.. ::: p, �.1 r',: , �; �' : 1 4 I' �,.., .:, ._:____ ____._.- ._-- -. -._. _._- .____- .__� -_.__„ ___ _ _ _.- __ -.__ ...,.._- __._.. - -_. - - - I- -I 1 - - L -f I - 4N IECf1 - 1 � I 1 EX TItJ6 eIRC�Jb� 1 I 1 1 I I + I II 1_ I -I- -1- -I - - �! . ._. _ _ ___._ _.. _. _ o ;r'; I CI XS r X ST f XST , I 1 1 1 -1 I---t _ a � : _ __ _. _ . _..__ _._ . - - - -. L __ _ T T r -- EXIST r EX T EX I _ ly _ L .__... _ - _ ' 1 1 1 1 L_ 1 - 1 I I T 'T EX IE X T r� 1 i 1 -1,1,,,, � , X w I 1 Fit-8-1r . -� 1 I I I I z 1 1 r ..;,r 1 1 1 11 1 h -ht 1 1- 1- ...._._ _ __.__ 1 :. .. J 1 1 1 ,' L . 1 1 1 1 I i, l 1 1 - _ I 1 _ L T. 111)C1 -. __. - __ ...,11 - T Loc LOC LQG 1 �� EXSr EXS EXSr EXS EXSr EXST EXST' '; VLOC LOC EOC LOC LOC LAC ,F - -_ ___. - __- _r. -. -.... . - .._.. ,,. ..__..__ ......... ....... ... .. . -... Lo I.. vn¢ OC LOC I I 'l 1'.1-x:1_ I ' I_.!_...il (''� , _ r rulr‘ t ,,' OOM AND 'r 9 I 1 - COLUMN 1 E302 PEER LLVFL LOOH PLAN SCALE: 1/8 " =1 -a GENERAL & ACCENT LIGHTING AA9 H. K. GENERAL NOTES A. ALL CEILING MOUNTED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE ARCHITECTURAL REFLECTIVE CEILING PLANS. IF A LOCATION FOR AN ITEM IS NOT SHOWN ON THE ARCHITECTURAL REFLECTIVE CEILING PLANS, VERIFY THE EXACT LOCATION OF THE ITEM WITH THE ARCHITECT /ENGINEER PRIOR TO INSTALLATION. THESE REQUIREMENTS APPLY TO ALL CEILINGS TYPES IN ALL AREAS. B. REFER TO ARCHITECTURAL, STRUCTURAL AND MECHANICAL DRAWINGS FOR GUIDANCE AND VERIFICATION OF DIMENSIONS, CEILING HEIGHTS, DOOR SWINGS, ROOM FINISHES AND LOCATION OF DUCTWORK, PIPES, STRUCTURAL STELL, EQUIPMENT, CABINET WORK AND FURNITURE. C. INSTALL WALL LIGHTING FIXTURES, WALL SWITCHES, WALL OUTLETS AND OTHER WALL MOUNTED EQUIPMENT IN STRICT COORDINATION WITH DETAILS, SECTIONS, ELEVATIONS AND ROOM FINISHES SHOWN ON ARCHITECTURAL DRAWINGS. D. FOR LIGHTING FIXTURES LOCATED IN GYPBOARD CEILINGS, CONFIRM LOCATION WITH JCP REPRESENTATIVE PRIOR TO INSTALLATION. E. PROVIDE AND INSTALL OCCUPANCY SENSORS IN FITTING ROOMS, STOCK ROOMS, TOILET ROOMS AND THE OFFICE AREA UNLESS OTHERWISE NOTEDED. OCCUPANCY SENSORS SHALL BE SENSORSWITCH INC. (PH: 800- 727 - 7483). COORDINATE LOCATIONS AND INSTALLATION REQUIREMENTS WITH MANUFACTURER'S REPRESENTATIVE. FIXTURES ON EMERGENCY POWER SHALL NOT BE CONTROLLED VIA MOTION SENSOR. F. ALL STORE LIGHTING, EXCEPT FOR FIXTURES ON EMERGENCY POWER, SHALL BE CONTROLLED VIA MOTORIZED CIRCUIT BREAKERS AND LIGHTING CONTROL MODULE IN UNITIZED SWITCHGEAR. CONTROL FUNCTIONS 'F1' THROUGH 'F5' SHALL BE ASSIGNED TO CIRCUIT BREAKERS VIA PROGRAMMING AT CONTROL MODULE USING INPUT SIGNAL FROM EMS PANEL. G. ALL LIGHTING CIRCUITS IN OFFICE AREA SHALL BE CONTROLLED VIA OCCUPANCY SENSORS ONLY ONCE INSTALLED, THE ELECTRICAL CONTRACTOR IS TO EXTEND THE TYPE 300 FIXTURES OUT OF THE HOUSING AND AIM THEM AT A 30 DEGREE ANGLE IN THE DIRECTION THAT THE ARROW INDICATES. ONCE INSTALLED, IT IS THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO AIM THE TYPE 387 LIGHT FIXTURES AT THE CENTERLINE OF THE JEWELRY CASE AT A POINT 6 INCHES IN FROM THE CUSTOMER SIDE. J. ONE POWER PACK IS NEEDED PER CIRCUIT /ZONE TO BE CONTROLLED BY LOW VOLTAGE SENSORS. PLEASE RECHECK COUNTS TO VERIFY THE NUMBER OF POWER PACKS NEEDED TO MAKE A COMPLETE SYSTEM. ADDITIONAL SENSORS MAY BE REQUIRED TO PROVIDE COMPLETE COVERAGE DEPENDING ON PARTITION, FURNITURE, AND SHELVING PLACEMENT L. SENSOR MASKING KITS MAY BE REQUIRED TO LIMIT COVERAGE DEPENDING ON YOUR REQUIREMENTS. KEY NOTES 0 EXISTING 2X4 LIGHT FIXTURES TO REMAIN. /:\ REMOVE ALL POWER AND TELE /DATA CONDUIT AND WIRING / ASSOCIATED WITH CASH WRAP. CONDUIT AND WIRING SHALL BE REMOVED TO FIRST J —BOX LOCATED ABOVE CEILING AND MARKED AS SPARE FOR REUSE IN FUTURE RENOVATION. 3 REMOVE EXISTING PANELS AND RECONNECT AS SHOWN. 3 FIELD VERIFY EXACT LOCATION AND CONNECTIONS PRIOR TO RELOCATING. G: 10706xxx1070601010706010 _E301- E302.dwg 11/12/07 NOV 21 2007 PFRMFF CLN"T1, c3:45:19 PM COPYRIGHT 2007 CALLISON INTRUSION ALARM DEVICE SYMBOLS DEVICE SYMBOL DETAIL RECESSED CONTACT p 17605 STROBE LIGHT WALL MOUNTED SOUNDER 17603 KEY PAD 17602, 17608 INFRA -RED DETECTOR (CLG. MOUNTED 360 DEGREE PATTERN) ( 17604 KNOX BOX K TYPICAL. FT ^dl... f!ISi:iiei; itS Hli S O..MMM tPffs(i':1.Is ^!R6 €(' 2211. ak.. fYlEF :1I!R'SPIR: ?S18iSktfHIBlix: s3Elk�il RtlF 7 t k 418H S t.S2 ilM MIIE!E €:IM 111;1: 2P::tP6Ptllid!l3.Chl6.ff<'Sli Pu11! J'i! '1Uf 9F e^ 3 1 .' v t it.Jl ST i LSi.lP; ?.t.33lC:tiftb!ZPf 4IiiIL °131(v.i1L'iftlli[+ Sf Mitt,ill ;Sl11 „1!„ 11,1' LSW.I.t.PS1F1.1n. 3 ,itl15W111.Ut'SJ; 1. t1.Mti11t0.11t:121:MI : e1 r 1:??t dI '+ 1 ' t . . tt 11711d.f „!le7:'I!i!!: i:S 1'Mlil .i� ( ', , � f IUiE 3 fit £S'i'.,.fi3i51:tE 4B117. OFFICE li ;d1tiV}111 DOORB TO SO zi EzafEET.7,;<CIIIun !RIM litnagtO W(i12111111:tttJ1 1I'Sd11 i l fitl!m'u; 1223 Ue'ea=, `.tf .. C'ti -.. •cam +!' ;f�'S17to4{tiS'1!!Y' iJllEf.t. F...,L f.S.Y.P. tC. - .,f Gt f!tY!I6.Pt „ISf..!f rtlF: 5111r.i.-lil'IlI.'S ( f7.iiif. tE+.Z:iY,4 °t'i:'. .. SS i : S I i,il.S..[.iKfP .itIMSIIMUPiIE141 f 4 FS. itIOHI S° iE ;.t:Sttklf11 1:nnii:tillf?I!i:i II:'11 to Pitt' P t i f! - 1 1.w P ! iB I. ,� fiz�t (:1,Ih;t1f32fiPi`if rill lt.t If ilEE32EUfi3fJ9di ":Sfd4 i 1(E 'U ( 3 +4; C tit. .tilt S3 h..i ISPRiiifPEl: iltaEliB (.:iii`:itiitlEfC!![F3.iiCF: ^.IelC977 %JEFIe ;tt7!':S <FStfdi .53171 f n J t F Ii EII.ISIPN:f iif9fiuLR1 I!ixtEPiPl:ilzldPJil'tv'F13� '" 1 1` .Z� .11,. HEP f151z(Jfr11:531 142( id 31 11 i:n!_t0.Ill'!%Idiliniitatil3t' ∎ ∎ : '.i.:.Pit_...11S1W ,: z, 11.: 14. z« 7tlJ W..1i[lnllieili46.l::,.t61Y1,e !t:Wili'.Sl.!411U1s SI Ct .^f.t:W0 ani t. + : IF tt 41 1 {4522'1tv..v+iHni.∎ usizmil:,:l'i " t .Eii N, B➢iFF: '2211! (i ll v54,F, ii'IZit tI P4. i.l flEllti i.. i'itt1Ev1P34F.iti? IIf' flit. ^ Y .o. Wtlf F 11 rY1H;YlEft1.1ifF 111 t , ''A' f t i , $If .il. LaP7S CSIt.42P7YSSitS' {51..1.2.!£ %tllJilih:fil!!i!t 1:f tii111113 i' SJilM1 111' dflit!llMIMi1111n Sili f +t t t 4f !P . tU! SlIeFYl?PIIPiiPEtFl Sd9RIf Tf.vM411'SSPfiif ;:]iltWlitfi ILSg51l ^ 1151 lif ° 6 1 Lt Sf I H 1NYilb3 llAltMi3t ,'ZZd[f'fii:YSIPf?}ll?FfSl11HPPH % LEV 4 SCALE: 1 /8 " =1' -0" 11.itiii'ISI.6ESf „f.F i3L1! ISi11Sifi 7!StSSIi.'z f " ,E t. I " "•' ' 7 (v..13 fll f t .)i..,.Mttltll� "iiithTltiP ": il'.i f' '' t' t;" _1 ni Y..ditlSAil! %Nrs4iMilIP it .N '.12.ii.:.C., 2 E401 EANZIK i 11.ltZ11 iNKIVII! ;r.1; LOWER SCALE: 1 /8' '-0" CONNECT TO EXISTING SOUND CIFCUIT. JUN K CONNECT T Y1 P:::mairSI e. .. ,i f, Ir iE.! E!P'tt i.f111i.mLownil Fm_'.,v19+7t':zttE EVEL Se ti'.IltfilMFi MiSliS Mik1tllli EMC!!IFitE!S'?!!l:1.;1M P1f i f ii [iilY °.tIYS1I[t;ffiliF'tile! EL FLOCK LA\ INTRUSION AND FIRE ALARM ii.li.IMI Irl`Itt341111'ISII!f:!!"t t::Sf:t'F:ti!!.Sitl .:MUI +'ti St �n +[ ^:' n • ^' 1 Y" k t . P_.. 7.. z <..➢�Yu :IF:tifE:,S:t11[{Sti1£f'• 1 2141! 1255:!::' � ! E E f .e 571! 93 _ !t Y.'1'1 :SSeT.Hf F EXISTING SOUND CIRCUIT. RS 1111!S';Itt'Yee ^ 'dn• 31 911X SIP31CS1ikISP: Z9Pi ;t'N:SIG.ItrPISEGtIIIi,S(SS211f tG58i?1.1101 ooP PLA\ SOUND AND PAGING ,8t.: ..9if:llEt.^ant S' 3,kire.mr.:?.[I. of fP9il� {l t�, i..tii.13l,:CiStikilaslf P;tlld kTa # ;it[ShIi1i0.7IP1t111t If�191cntCE639lSdi iPllf ?;IS3'. t ➢tdiPSIL.P(EtiY :PG 11Nwinmniailiimumunia !:! Si: 21!'! '.IP;tl:i!t'Si7f;L'fYf.el.f1?t I t blt i 1313th t.' lft`1111lt•lliHtS OWW711 ;.dlf:lPilt;.lt s x.; 553.!3.4.1 I... L:i.. I.VJ Elio.f.:lI U {,tl1IWM1„r.[ail i,I.t R11 ?PiPt!llfiiit.VIM._ttt M f ,.: ∎ -' e • %• s M111 y � v h tV 45 &i'r)lt ��111.f f!£4.4I.i, ft, ,3,,,.rta.l....F @ i,ft∎,.! ' ±i1S7 �S431: r1f3K: PlESS7DS:7 �CIRBY!✓ ss; ?SZ,] HY';: Plx»itPSHiS4 "7(lii:SI6LFSSitifl Lrei9ifiiPith.i._^hil,SS f l:1 V.FC;4teE':75t:3llSdA P)isLltl.�519 F t i P tH! ?t E±: t SPi} t: S:' k"" 1 S2tS1iYP. lf, St. 3S.= PPt,: drP3ll.'! SIf::!1 9Y1R' 11kt1P} yt1tL `!1!i'3.iITi1FClTiFi'"..�(e"il ilE'.Iiltl.tl., ,1.5.4:.2∎1 1,itta'l!osiu FIV,9IP. tu,Ctial,IL IPW.,.1-IA..Y:}.lMt MU611'MW,E:HEI1 };f'.Stf 7411.91 tiff lE:ttti17ii5Yiittuft S tiII AIW E.'., 51714C! S13i11lStci4sit7f;StYYdtivPiitl `Y6fPdttt;., fticpttlPitlo ~ °St:SS4117fi111E:1Ef`titlEtlk} i7311.1E6 SES9 IS 311, iP.'. l 15 : IPglf f) IY ilf€ 1 iLldtRtF! s itlPL 43 : Id 7 u€ 1 ti + 6eftiili if i? SItYSIS PifilYliEtil @llfii[IllSti{F'eillil;RiiSB +- 0 16'? t!) S' 3i[ iFkiS2lplkL 'Il71tl1Kfi1[iVtilSeid tt. ltlilFlli( lLliltiltalY{ viF41I:± 81. 76iIPllifltEPr 111CL[!t)IftllY4 i.,f33ei,.F.a.F1.G1S.l : if : lltSt9'.6t1t4t4iti6 - §P ...S.,t:_,tdet21131;tf Il�;tsrs to ': Cr: fa. fll�Eft51IS} IGPtdtFlFi~iiY31i4f41kYF3iZLti! s 1.5:'7.1 bIP� !!sa?eidS ;e� GENERAL NOTES: A. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING AND CONSTRUCTION AS NEEDED PER AS- BUILT. B. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS. C. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. GENERAL NOTES -FIRE ALARM NO INTRUSION AND /OR FIRE ALARM DEVICE SHALL BE LOCATED ON COLUMNS IN THE SALES AREA OF THE STORE UNLESS NOTED OTHERWISE. B. FIRE ALARM NOTIFICATION DEVICES IN THE SALES AREA SHALL BE LOCATED ON THE CEILING 40' ON CENTER AND SHALL BE WHITE. IF CEILING MOUNTED STROBE DOES NOT COMPLY WITH LOCAL CODE CONTRACTOR SHALL MOUNT DEVICE ON NEAREST COLUMN. C. FIRE ALARM SYSTEM INSTALLER SHALL VERIFY THAT SYSTEM COMPLIES WITH LOCAL FIRE MARSHALL REGULATIONS. D. ALL FIRE AND INTRUSION ALARM DEVICE ROUGH -INS SHALL BE INSTAI I FD IN ACCORDANCE WITH CITY APPROVED "ADT" DRAWINGS. E. LOCATE ALL VISUAL DEVICES AT NOT MORE THAN 80" ABOVE FINISHED FLOOR PER ADA REQUIREMENTS. F. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE RETURN DUCT UNLESS LOCAL CODE REQUIRES A DETECTOR TO BE PLACED IN BOTH THE SUPPLY AND THE RETURN. G. ACTIVATION OF A DUCT SMOKE DETECTOR SHALL SHUT DOWN ONLY IT'S ASSOCIATED RTU. H. WIRING BELOW THE STOCK ROOM MEZZANINE DECK SHALL BE INSTALLED IN CONDUIT. KEY NOTES -FIRE ALARM n NEW FIRE ALARM DEVICE TO BE PROVIDED. TIE INTO EXISTING FIRE ALARM SYSTEM FOR A COMPLETE OPERATIONAL SYSTEM. FIRE ALARM LEGEND DEVICE SYMBOL REMARKS HORN STROBE CANDELA INDICATED TO 96 OR AFF TO TOP GANG, 4' X SQUARE BOX 84" GENERAL NOTES -SOUND + PAGING 1. GROUND DRAIN WIRE AT SOUND CONSOLE ONLY. 2. MAXIMUM 35 SPEAKERS ON CIRCUIT. 3. SPEAKERS COVER 900 SQ. FT. AVERAGE. 4. SPEAKERS ON MAXIMUM 30' --O" ON CENTER, 5. VOLUME CONTROLS FOR FITTING ROOMS ON SAME FLOOR SHALL BE ON A COMMON SOUND CABLE, DEDICATED TO FITTING ROOMS. LIMIT 12 VOL. CONTROLS PER HOMERUN. THERE ALSO SHALL BE A DEDICATED SOUND CABLE HOMERUN FOR REMOTE OFFICES. 6. SYSTEM DISTRIBUTION FOR INFORMATION AND ILLUSTRATION (COMPOSITE) 7. REFERENCES: JCPENNEY ARCHITECT' MASTER CONTRACT SPECIFICATIONS. 8. 2 CONDUCTOR #18 STRANDED, TWISTED SHIELD, JACKETED CABLE BY ELECT- CONTRACTOR FOR DIAL ACCESS PAGING INTERFACE. CONTRACTOR TO TERMINATE ON FOUR POST TERMINAL STRIP ON TELEPHONE BACKBOARD AND LEAVE 10 FEET OF SLACK BEHIND SOUND CONSOLE AND TAGGED AS "PAGING LOOP ". 9. ALL DEVICES, SPEAKERS AND WIRING ABOVE CEILING SHALL BE PLENUM RATED. 10. SEE SPECIFICATION FOR PAGING ZONES. 11. ALL SPEAKERS SHALL BE TAPPED AT 1 WATT EXCEPT FOR THE SPEAKERS IN THE SALON WHICH SHALL BE TAPPED AT 8 WATTS. 12. ALL HOMERUNS SHALL LAND IN SOUND CONSOLE LOCATED IN OMR RnOM 13. WALL SPEAKERS SHALL BE INSTALLED AT 8' -0" AFF ON CENTER. WALL MOUNTED SPEAKERS LOCATED IN 2ND LEVEL STOCK ROOMS SHALL BE MOUNTED AT 6'--0" AFF ON CENTER. 14. ELECTRICAL CONTRACTOR SHALL PULL ALL HOMERUNS TO SOUND CONSOLE LOCATED IN OMR ROOM AND SHALL CLEARLY LABEL EACH CABLE AS INDICATED ON THIS PLAN. TERMINATION OF CONDUCTORS AT THE SOUND CONSOLE SHALL BE BY OTHERS KEY NOTES- SOUND AND PAGING Q BUZZER TO BE CONNECTED TO SOUND CONSOLE. REFER TO ARCHITECTURAL VESTIBULE DETAIL FOR MOUNTING HEIGHT ON SHEET A302. G: 10706xxx1070601010706010 T E401- E402.dwg 11/12/07 c3:43:10 PM NOV 2 7 2007 se ;�rl CENTER COPYRIGHT 2007 CALLISON INTRUSION ALARM DEVICE SYMBOLS DEVICE SYMBOL DETAIL RECESSED CONTACT D 17605 STROBE LIGHT WALL MOUNTED SOUNDER 0 17603 KEY PAD 0 17602, 17608 INFRA -RED DETECTOR p (CLG. MOUNTED 360 DEGREE PATTERN) Ii l 17604 KNOX BOX C APPARE1 h /. iAf 'PAREL 7 -r !i 7Z.Z __ /_.___ .'......I r _ 2..: iY .A7=7iG""u^: a=77.a'1dd "Xv... v,._....a.:,.3 q TYPICAL. :,.. ,ems :; CANIPC, : 1'• A' 1: �.. h 4! r l 30CD e�htrka�csass p}- ,. �E 402 2 E402 ::7. <._,.,.=',U7szr_ ;,..,.,a. ,1 YOUNG MENS cc !�v�: JPPER LEVEL FLOOR PLA SCALE: 1 /8 " =1' -0" r: k SCALE: 1 /8 " =1'�0" $h DOOR6�LL HOMERUN TO SO D CONSOLE 30CD- INTRUSION AND FIRE ALARM 77,7..,..10::1. AND / 'a'/PI �..: a•! z. r._,,, v�. xzn�a ::,n..,,.,raarssr.:cre're� iOdx 777: i" XIS; i1; Dt „ { I - X ! AND HI TING O •r -,, III 'VV !�1�'�,ll,l HC"" - SELLING NEW CEII.ING, LIGHTING, \JAC AND ! i EXISTING SALES 7 SOUND AND PAGING rzwl oraro•...r ,rsts.;no..,r_v..romul' c. ...:d�...r z. ^.a PPER LFVFL FLOOR PLA\ - 7 a:A l !.(Kjli!.f) rANF S " AND ! "3`e., X ISI - , I:i , I � . Z1 lMl� 30CD / . /CONNECT TO EXISTING SOUND CIRCUIT. H.:G_= '41=1,X':. �:•{.tit:wa: . XiOidO.rod i..x,.c.9 5_4) GENERAL NOTES: A. MAKE ANY CHANGES NECESSARY TO ZONING, DEVICE RELOCATION, WIRING AND CONSTRUCTION AS NEEDED PER AS- BUILT. B. SEE JCP DETAIL DRAWINGS FOR ACTUAL INSTALLATION REQUIREMENTS, C. ACTUAL WIRING LAYOUT ON FLOOR PLAN IS DIAGRAMMATIC. GENERAL NOTES -FIRE ALARM A. NO INTRUSION AND /OR FIRE ALARM DEVICE SHALL BE LOCATED ON COLUMNS IN THE SALES AREA OF THE STORE UNLESS NOTED OTHERWISE. FIRE ALARM NOTIFICATION DEVICES IN THE SALES AREA SHALL BE LOCATED ON THE CEILING 40' ON CENTER AND SHALL BE WHITE. IF CEILING MOUNTED STROBE DOES NOT COMPLY WITH LOCAL CODE CONTRACTOR SHALL MOUNT DEVICE ON NEAREST COLUMN. C. FIRE ALARM SYSTEM INSTALLER SHALL VERIFY THAT SYSTEM COMPLIES WITH LOCAL FIRE MARSHALL REGULATIONS. D. ALL FIRE AND INTRUSION ALARM DEVICE ROUGH -INS SHALL BE INSTALLED IN ACCORDANCE WITH CRY APPROVED "ADT" DRAWINGS. E. LOCATE ALL VISUAL DEVICES AT NOT MORE THAN 80" ABOVE FINISHED FLOOR PER ADA REQUIREMENTS. F. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE RETURN DUCT UNLESS LOCAL CODE REQUIRES A DEILCTOR TO BE PLACED IN BOTH THE SUPPLY AND THE RETURN. G. ACTIVATION OF A DUCT SMOKE DETECTOR SHALL SHUT DOWN ONLY IT'S ASSOCIATED RTU. H. WIRING BELOW THE STOCK ROOM MEZZANINE DECK SHALL BE INSTALLED IN CONDUIT. KEY NOTES -FIRE ALARM n ( -- 1 NEW FIRE ALARM DEVICE TO BE PROVIDED. TIE INTO EXISTING FIRE ALARM SYSTEM FOR A COMPLETE OPERATIONAL SYSTEM. DEVICE FIRE ALARM LEGEND SYMBOL HORN STROBE CANDELLA INDICATED 1. GROUND DRAIN WIRE AT SOUND CONSOLE ONLY. 2. MAXIMUM 35 SPEAKERS ON CIRCUIT. 3. SPEAKERS COVER 900 SQ. FT. AVERAGE. 4. SPEAKERS ON MAXIMUM 30' -0" ON CENTER. 5. VOLUME CONTROLS FOR FITTING ROOMS ON SAME FLOOR SHALL BE ON A COMMON SOUND CABLE, DEDICATED TO FITTING ROOMS. LIMIT 12 VOL. CONTROLS PER HOMERUN. THERE ALSO SHALL BE A DEDICATED SOUND CABLE HOMERUN FOR REMOTE OFFICES. 6. SYSTEM DISTRIBUTION FOR INFORMATION AND ILLUSTRATION (COMPOSITE) 7. REFERENCES: JCPENNEY ARCHITECT' MASTER CONTRACT SPECIFICATIONS. 8. 2 CONDUCTOR #18 STRANDED, TWISTED SHIELD, JACKETED CABLE BY ELECT- CONTRACTOR FOR DIAL ACCESS PAGING INTERFACE. CONTRACTOR TO TERMINATE ON FOUR POST TERMINAL STRIP ON TELEPHONE BACKBOARD AND LEAVE 10 FEET OF SLACK BEHIND SOUND CONSOLE AND TAGGED AS "PAGING LOOP ". 9. ALL DEVICES, SPEAKERS AND WIRING ABOVE CEILING SHALL BE PLENUM RATED. 10. SEE SPECIFICATION FOR PAGING ZONES. 11. ALL SPEAKERS SHALL BE TAPPED AT 1 WATT EXCEPT FOR THE SPEAKERS IN THE SALON WHICH SHALL BE TAPPED AT 8 WATTS. 12. ALL HOMERUNS SHALL LAND IN SOUND CONSOLE LOCATED IN OMR ROOM. 13. WALL SPEAKERS SHALL BE INSTALLED AT 8' -O " AFF ON CENTER. WALL MOUNTED SPEAKERS LOCATED IN 2ND LEVEL STOCK ROOMS SHALL BE MOUNTED AT 6' -0" AFF ON CENTER. 14. ELECTRICAL CONTRACTOR SHALL PULL ALL HOMERUNS TO SOUND CONSOLE LOCATED IN OMR ROOM AND SHALL CLEARLY LABEL EACH CABLE AS INDICATED ON THIS PLAN. TERMINATION OF CONDUCTORS AT THE SOUND CONSOLE SHALL BE BY OTHERS KEY NOTES- SOUND AND PAGING O BUZZER TO BE CONNECTED TO SOUND CONSOLE. REFER TO ARCHITECTURAL VESTIBULE DETAIL FOR MOUNTING HEIGHT ON SHEET A302. REMARKS SINGLE 96 F BLE GA, 4" SQUARE BOX 84" GENERAL NOTES -SOUND + PAGING t 4 ^i.... 4l FI NOV 2 7 2007 CENTER G: 10706xxx 1070601010706010_E401- E402.dwg 11112/07 c3:44:31 PM COPYRIGHT 2007 CALLISON EXPO ES 07 / • 1 /t.3 r�. NOV 1 2 2007 07 • CD co >- w W a V CO LLI CO Q cI a. E N S a z . . __ w Z z U LLCJ o -_) c0 a 2 0 U) J J U di 65 gy N N 2 0 rn s co 00 N 0 L - e Q.) co a o no <cz ISSUED / REVISED DATE 55 0 0 U) C 0 0 0 0 0 0 E PERMIT / PRICING ISSUE 11 .09.07 PERMIT ISSUE UPPER LEVEL FLOOR PLAN FIRE ALARM SOUND AND PAGING INTRUSION ALARM E402 rE:2s.�.x a�ea�rrnr.. . =? :., 51`b?.G�i l3'`f"*"�^G'3td3' , ;::t•y rcerld.. a"ac,,. itof=.i tay.m+.Mt1=1:51 / R A P N! C /;Th>!d N rag t' 2 C I E501 SCALE 1/8 " =1_0 501 YSCALE: 1 /8 " =1' -0" 4 %x :a 4 R LEVEL tam, mit .3 JUN k�iX""a..i15Y x£iu:Y' .�, iYY lYfz 4 '+3 «uaf, "aH a:63=ffiC°'1^Cd' LOOR PLA\ POWER JPPER LEVEL FLOOR PLA\ POWER H': iE .. J CKP. F .. M k= .,uiaeatz.t , w . .4.iu�- �CLu?li ::l'Sf.'��:5:1 a.`d..'..' ."'+ES`.:bd" "tip ALL DEVICES SHOWN ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE BY CODED NOTE. GENERAL NOTES A. COORDINATE THE LOCATION OF ALL POWER DEVICES WITH THE LATEST JCPENNEY FIXTURE PLAN PRIOR TO INSTALLATION. B. REFER TO THE MECHANICAL PLAN FOR THE EXACT LOCATION OF ALL HVAC EQUIPMENT. C. * = INDICATED DEVICES CONTROLLED BY LIGHTING CONTROL SYSTEM. D. ALL POINT OF SALE RECEPTACLES SHALL BE CONNECTED TO AN ISOLATED GROUND CIRCUIT. REFER TO MASTER CONTRACT SPECIFICATIONS AND 16796 SERIES STANDARD DETAILS. E. REFER TO MASTER CONTRACT SPECIFICATIONS AND 16796 SERIES STANDARD DETAILS FOR COMMUNICATION CABLE REQUIREMENTS. F. THE CONTRACTOR SHALL PROVIDE AS -BUILT DRAWINGS WITH THE EXACT CIRCUIT NUMBERS USED AND PROVIDE TYPE WRITTEN DIRECTORY CARD IN PANELBOARD REFLECTING THE CORRECT INSTALLATION. G. ALL LIGHTING IN SALON SHALL BE ON HOUSEKEEPING FUNCTION "Fl" KEY NOTES — POWER TRENCH FLOOR FOR CONDUIT INSTALLATION. PROVIDE 3/4" CONDUIT FOR POWER AND 1" CONDUIT FOR SHARED SIGNAL (P0S Sc TELE.) WITH PULLCORD. RISE UP AT COLUMN TO ACCESSIBLE CEILING. CONDUIT SHOWN IS DIAGRAMATIC. CONTRACTOR TO ADJUST IN THE HELD ( EXISTING CONDUITS AND BRANCH FEEDERS FOR REGISTERS AT CASH ��- WRAP IN SLAB. EXTEND EXISTING TELECOMUNICATION WIRING AND BRANCH CIRCUITING AS REQUIRED FOR NEW CASH WRAP LOCATION. EXISTING OUTLETS LOCATED IN CASH WRAP. OUTLETS SHALL REMAIN IN PLACE. CI) GANG WATER TIGHT FLOOR BOX FOR CASH-WRAP POWER P.O.S. AND TELEPHONE FLOOR OUTLETS. SEE JCPENNEY DETAIL 16796H1. (� REFER TO CODED NOTE 1 FOR TRENCHING. CONNECT EXISTING \ / CASHWRAP CIRCUITS AS NEEDED FOR NEW CASHWRAP LOCATION. FIELD VERIFY EXACT LOCATIONS PRIOR TRENCHING AND CIRCUITING. ott R.6 q a42) f ,, NOV 2 7 2007 iivl I CENTER G: 10706xxx1070601010706010 _E601.dwg 11112107 c3:42:00 PM COPYRIGHT 2007 CALLISON s7 -f t r (_ wavavw�n s` .1:% amq � . .�as++.r sx NOV 1 2 2007 z 0 c) 1 U aC> Z LI co L 1. rY 2 Quti z W 62 in —I L1.1 0 Z O '7 CL? a. F - LL. E501 E 0 0 to ai C 0 0 N 0 a Cot 0 CC) I cep c(oo ISSUED / REVISED DATE PERMIT / PRICING ISSUE 11.09.07 PERMIT ISSUE LOWER & UPPER LEVEL FLOOR PLAN POWER r) r r MOW cn re" r q. WALL ARTS LIST 1 - 1 1 . BEHIND LIGHTBOX . CLEAR PLASTIC BOX 2. LAMP i. LAMP HOLDER I. SOCKET i. BALLAST SEC ION ELEVATION LAMP (2) PL--L 24W/841 REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. BALLAST (1) QUICK START BALLAST REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR FINISH WHITE MOUNTING SURFACE APPROVED MANUFACTURERS MIRAMAR 16500-C VESTIBULE LIGHT BOX SCALE: NONE 07 -10_03 i se II1 I IIIIIII II IIIIII II /, 0 1.l Ei 11 Min. Max. 5 7 3/8" Dia. 7 7/8" Flush SECTION VIEW 8 - 5/8" Overlap 1 -1/8" Max. Ceiling Thickness 3 PARTS UST 1. REFLECTOR 2. SOCKET CUP 3. MOUNTING FRAME 4, RETAINING SPRINGS 5. MOUNTING BRACKETS 6. BALLAST ASSEMBLY /J -BOX 7. REFLECTOR TRIM LAMP (1) - F42 PL -T REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. MOUNTING RECESSED APPROVED MANUFACTURER REFER TO SPECIFICATIONS PHOTOMETRICS 1 1S" 250 411 s�IIo 750 1000. IAO _ -a LAMP LUMENS; 3200 FIXTURE EFF.: 63 Min. S /MH RATIO: 1.1:1 16512E3 LIGHTING FIXTURE -TYPE 128 SCALE: NONE 01 -01 -02 PARTS ST 1. LOUSING 2. BALLAST 3. AMP 4. MOUNTING 5. REFLECTOR 6. MOVABLE SOCKET /HINGE PLATE 7. FIXED WHITE REFLECTOR SECTION VIEW LAMP (1) F4OBX/ _ REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. MOUNTING SURFACE MOUNT PENDANT MOUNT APPROVED MANUFACTURER REFER TO SPECIFICATIONS 1 del. LIGHTING FIXTURE -TYPE 149 SCALE: NONE PLAN SYMBOL INITIAL RATED LAMP LUMENS : 3150 LUMENS FIXT. EFF. : - S/MH RATIO : - - 2 0 2 0 1 1 PARTS UST FT] MATTE NICKEL CANOPY fi MOUNTING CEIUNG LAMP MATTE NICKEL PENDANT - 36" WHITE LINEN ACRYUC SHADE (1) 13W COMPACT FLUORESCENT REFER TO SPECIFICATIONS APPROVED MANUFACTURES REFER TO SPECIFICATIONS LIGHTING FIXTURE -TYPE 130 165130 SCALE: NONE 01 -01 -02 SECTION EL IVATI O N END VIEt1� ( *1 1653000-D SCALE: NONE LIGHTING FIXTURE -TYPE 3000 -D 07-07-06 PLAN SYMBOL N TYPE: 30/4 30/8 30/8E 30/8M 30/8S 30/12 LENGTH: 48" 96" 96" 96" 96" 96 " +48" PARTS UST 1. HOUSING 2. REFLECTOR 3, SOCKET 4. BALLAST 5. LAMP 6. DPST TEST SWITCH (NOT SHOWN) 30/8E ONLY 7. CABLE ASSEMBLY WITH CONNECTOR 130/8M, 130 /8S AND 130/12 ONLY LAMP 1 F32T8 - - -- TYPE 130/4 (2) F32T8 - - -- TYPE 130/8, 130/8E (2) F32T8 - - -- TYPE 130/8M, 130/8S (3) F32T8 - - -- TYPE 130/12 REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. MOUNTING SURFACE MOUNT PENDANT MOUNT PHOTOMETRICS LAMP LUMENS:2850, 5700 (INWAL) FIXTURE EFF: 81% S /MH RATIO: 1.41 PERP. 1.37 PARALLEL I-0I 1 ---- - 1 PLAN SYMBOL PARTS UST 1. HOUSING 2. REFLECTOR 3. SOCKET 4. LAMP 5. BALLAST 6. LENS 7. YOKE 8. 1/4 -14 N.P.S. CONNECTOR 9. INITIAL AIMING ANGLE = 60' LAMP (2) F25T8 REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. MOUNTING YOKE MOUNT APPROVED MANUFACTURERS REFER TO SPECIFICATIONS EXTERIOR LIGHTING FIXTURE - TYPE 184 165184 S CALE : NONE 01 -01 -04 PLAN SYMBOL PARTS UST 1. HOUSING 2. REFLECTOR 3. SHIELDING 4. LAMP 5, BALAST 23.750" x 23.750" 24.00" x 24.00" GRID DIMENSION SECTION VIEW MOUNTING LAY -IN CEILING PLASTER /GYPBOARD APPROVED MANUFACTURER REFER TO SPECIFICATIONS vvr LAMP (3) 40W COMPACT FLUORESCENT REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. ® 3 INITIAL RATED LAMP LUMENS : 3150 LUMENS FIXT. EFF. : 68.0 MIN. S /MH RATIO : - - LIGHTING FIXTURE -TYPE 120/ 120E „< ►y, E 165120 SCALE NONE 01 -01 -02 PLAN SYMBOL 2 5/8" Lr� TYPE: 31/4 31/8 31/8E LENGTH: 48" 96" 96" LENGTH PARTS LIST 1 HOUSING 2 WIRE GUARD 3 SOCKET 4 BALLAST 6 DPST TEST SWITCH (NOT SHOWN) 131/8E LAMP (1) F32T8 - - -- TYPE 131/4 (2) F32T8 - - -- TYPE 131/8 (2) F32T8 - - -- TYPE 131/8E REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. MOUNTING SURFACE MOUNT PENDANT MOUNT PHOTOMETRICS: LAMP LUMENS: 2850 ,5700 (INITIAL) FIXTURE EFF. 91.4% S /MH RATIO: 1.4 6513.1 L sc I A G L I-I N TING FIXTURE - TYPE 131/4 131/8 131/8E 01 -01 -02 - S.A.C. MOUNTING OPTION 1 `f" - GRID FRAMING REQUIRED MDUNTING OPTION FLANGED FRAME PROVIDED -1.500 REGRESS (TYP.) GYPBOARD CEIUNG PLAN SYMBOL PARTS UST 1. LAMP 2. BALLAST 3. HOUSING RECESSED MOUNTING OPTION 1 FOR FIXTURE TYPE 300 OPTION 2 FOR FIXTURE TYPE 300F LAMP (2) 39W PAR 30 METAL HALIDE REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. APPROVED MANUFACTURER REFER TO SPECIFICATIONS BALLAST (2) 39W ELECTRONIC UNIVERSAL VOLTAGE METAL HALIDE BALLASTS .15 AMP EACH AT 277V HOUSING 20 GA HOUSING, WHITE POLYESTER POWDER COATED FINISH LIGHTING FIXTURE -TYPE 300 & 300F 165300 SCALE: NONE 01-01-04 PLAN SYMBOL BOTTOM VIEW PERFORATED HOUSING - 3 - P LIGHT SLOTS TOP VIEW PARTS LIST 1. HOUSING 2. LAMPS 3. SOCKET 4. SHIELDING 3. BALLAST BALLAST (2) 277V TWO-LAMP ELECTRONIC TYPE LAMP (4) 18W QUAD CFL REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. SHIELDING .062 MATTE WHITE ACRYUC LENS SOCKET POLYCARBONATE G240 -2 BASE MOUNTING SURFACE HOUSING DIE FORMED .060 ALUMINUM SIDES, WfFH PERFORATED AREA, AS NOTED. NATURAL BRUSHED FINISH WITH CLEAR COAT. HOUSING TOP TO HAVE (8) UP -UGGHT SLOTS & BACK MOUNTING BOX. APPROVED MANUFACTURER REFER TO SPECIFICATIONS -165125 LIGHTING FIXTURE -TYPE 125 SCALE: NONE 01 -01 -03 1 1 1 11 11 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 war 8 5/8" 7 3/8" PARTS LIST 1. TWO -PIECE REFLECTOR 2. IAMPHOLDER HOUSING 3. BALLAST ASSEMBLY 4. MOUNTING FRAME 5. MOLDED TRIM RING LAMP (2) F13BX - -- REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. APPROVED MANUFACTURERS REFER TO SPECIFICATIONS E LIGHTING FIXTURE -TYPE 145 1 6 1 45 SCALE: NONE 01-01-02 GYPBOARD/ PLASTER CEIUNG PLAN SYMBOL PLAN SYMBOL PARTS LIST 1. SOCKET HOUSING 2. SOCKET 3. REFLECTOR 4. GLASS SHIELD - TEMPERED 5. BALLAST CONTAINER 6. TRIM CONE 7. FUSE AND FUSE HOLDER 8. RAIL SUPPORT (2) 9. LAMP - METAL HALIDE 10. NEOPRENE GASKET LAMPS 100 WATT - METAL HALIDE, COATED REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. MOUNTING GYPBOARD /PLASTER CEIUNG APPROVED MANUFACTURERS REFER TO SPECIFICATIONS MINIMUM EFFICIENCY: 65% SPACING: 1.0 LIGHTING FIXTURE -TYPE 366 165366 SCALE: NONE 01 -01 -02 cp PLAN SYMBOL L CTRICAL. DESIG\ A. SELECT ONLY THE APPLICABLE DETAILS SPECIFIC TO THE PROJECT. B. VERIFY LATEST DETAILS ON JC PENNEY'S BUZZSAW SITE. \OT=S CEPry NOV 2 7 2007 f E.l liyil ( CEN FE' G: 10706xxx1070601010706010 _E701.dwg 11112/07 c3:40:00 PM COPYRIGHT 2007 CALLISON TO ' 491 1. F.F. DETAIL_ 'A' I / / / Ai izeizrizo rd.; lif II El d d El El El J 0 PARTS LIST 1. HOUSING CAN 2. LOWER PAN 3. SOCKETS 4. ADJUSTMENT YOKE: ALLOWS 0 -30' FROM VERTICAL ADJUSTMENT. 5. TRIM: SELF TRIMMED 6. J -BOX 7, LAMP 8. BALLAST SECTION VIEW LAMP MOUNTING RECESSED APPROVED MANUFACTURER REFER TO SPECIFICATIONS ROUGH IN 6 3/8"0 (1) - PAR30, METAL HALIDE, 39W MAX. REFER TO SPECIFICATIONS AND FIXTURE SCHEDULE ON PLANS FOR EXACT LAMP. 1 65387 LIG HTING FIXTURE -TYPE 387 SCALE N ONE 01-01 -04 COMM CABLE BY NCR 105362 BY E C. (TYP.) POS TERMINAL POS TERMINAL TERMINAL POWER CORD POS CABLE BY E.C. NCR PC8/7003 CABLES BY 1 D POWER CORD WALL DATA OUTLET BY E.C. SUTTLE SE -498A OR EQUAL MOUNTED IN CASH STAND (TYP. 2 PLACES) NCR "J" BOX 7003 PROCESSOR FURNISHED BY JCP, INSTALLED BY E.C. MOUNT ON WALL AT PROCESSOR LOCATION MONITOR KEYBOARD CABLE BY MODEM INSTALLER NOTES: 1. THIS DIAGRAM IS SCHEMATIC ONLY. REFER TO PLANS FOR EXACT LOCATIONS OF EQUIPMENT AND OUTLETS. 2. ELECTRICAL CONTRACTOR FURNISHES AND INSTALLS 4 PR. TELEPHONE CABLES. LEAVE 6 FT. OF SLACK AT BOTH ENDS. CONNECTION BY OTHERS. TELEPHONE LINE TO TELEPHONE CABINET SEE NOTE 2 POWER CORD 6411 PRINTER POWER CORD MODEM WALL JACK BY PHONE INSTALLER POs RISER - CATALOG SALES CENTERS 16795E SCALE: NONE xx-xx-xx •• CeIlIng Tile•: .CeIlIng The cut awa CeIlIng Tile CeIlIng N TRe Grid 4"X4-"X 2 -1/8" DEEP JBOX & W /WIRE CLAMP, NO COVER, (BY E.C.) Ceiling Tile- . PLAN ile- PLAN SYMBOL CEILING MOUNTING DETAIL . „op. I O+ M 7 R Q �BQX NTE ..._ . CEIUNG TILE .; • 3/4" CONDUIT (BY E.C.) • 2 "X4"X2 -1/8" DEEP .: JBOX FLUSH MOUNTED]' • WITHOUT COVER (BY EC.) FOR I.R. HEAD ''.. 4'X4 "X DEEP JBOX w /COVER & WIRE CLAMP (BY EC.) NOTES: 1, ALL STORES WHERE APPLICABLE. 2. COORDINATE LOCATION OF JBOXES WITH ARCHITECTURAL DETAILS. 3. ALL CONDUITS SHALL CONTAIN PULL STRING. 4. DO NOT MOUNT ON MIRRORED SURFACE. 5. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. WALL, COLUMN OR SOFFIT MOUNTING DETAIL 17604-A SCALE: NONE MOTION DETECTOR MOUNTING DETAILS 03 -23 -06 PARTS LIST 13 3/8" 1. FACE WITH 2 PRYOUT DIRECTIONAL ARROWS 2. DIODES 3. ACRYLIC SCREENED RED GRAPHICS 4. CEILING MOUNT (OR AS REQUIRED) 5. BATTERY UNIT, TYPE 498/E ONLY (NOT SHOWN) MOUNTING UNIVERSAL MOUNT SOLID STATE LIGHT EMITTING DIODES LAMP APPROVED MANUFACTURERS REFER TO SPECIFICATIONS 165498 LIGHTING FIXTURE -TYPE 498/E SCALE NONE 01 -01 -02 V O TYPICAL P.O.S. TERMINAL -- FLOOR OUTLET SINGLE ROUND MULTI - SERVICE FLOOR BOX DATA RECEPTACLE FEMALE MODULAR RJ -45 TYPICAL P.O.S. TERMINAL - WALL OUTLET (See Detail 1 6796-H 1 /DE T. "A ") P.O.S. TERMINAL TYPICAL P.O.S. TERMINAL - FLOOR OUTLET ON GRADE SLAB TYPICAL P.O.S. TERMINAL - CATALOG /CREDIT COUNTER and 2 OR MORE AT SINGLE LOCATION (See Detail 16796 -H 1 /DET. "C ") TYPICAL P.O.S. TERMINAL - UPPER LEVELS (See Detail 1 6797 -H1) POKE -THRU DEVICE USED. ti e=r ti FLUSH FLOOR BOX HUBBELL 105362 WALL BOX OUTLETS AS REQUIRED FLU SH FLOOR V TYPICAL WORKSTATION TELEPHONE WIRE (TYP TO ALL P.O.S. SIGNAL CABLES GENERAL NOTES: TERMINAL LOCATIONS) SEE NOTE 3 1. CIRCUITS FOR OUTLETS SUPPLYING P.O.S. TERMINALS, WORKSTATION AND PRINTERS SHALL ORIGINATE AT 120/208V PANELS HAVING ISOLATED GROUND BUS PER SPECIFICATIONS. 2. MAXIMUM OF FOUR (4) OUTLETS ON EACH DEDICATED 120V/20 AMP CIRCUIT SERVING P.O.S. TERMINALS, PC /CRT, AND PRINTERS. PROVIDE LOCK -DOG (S) ON CIRCUIT BREAKERS. 3, ALL P.O.S. AND WORKSTATION CABLES GO TO INTERMEDIATE HUB LOCATIONS, OR (RUNS LESS THAN 300') DIRECTLY TO Q.M.R. TELEPHONE CABLES GO TO REMOTE BACKBOARDS (PHONE CABLES BY E.C., P.O.S. /P.C. CABLES BY DATATREND). 4. REFERENCES: JCPenney DESIGN /MASTER CONTRACT SPECIFICATIONS, JCPenney CRITERIA PACKAGE AND STANDARD DETAILS 16796 SERIES AND 16793 SERIES. P.0.5. /WORKSTATION CABLES BY DATATREND 16796 -A SCAL POE: SNONE /W ORKSTATION RISER DIAGRAM (CAT5E) 07 -01 -02 TERMINATE W4' CONDUIT WITH PULL STRING INTO E.C, PROVIDED JBOX ABOVE CEILING IN CART STORAGE AREA. PULL STRING D TAIL "A" INTERIOR ELEVATION OF EXTERIOR DOORS G.C. TO COORDINATE HOLE LOCATION(s) W /IAC 24" PULL STRING BEYOND HOLE LOCATION LOCATE CONDUIT STUB, W /BUSHING, THROUGH CENTER LINE OF HOLLOW METAL DOOR FRAME (TYPICAL) A INTERIOR VESTIB CEIUNG E.C. TO STUB 3/4" CONDUff INTO FRAME METAL STORE FRONT FRAME HEADER INTERIOR PULL STRING SECTION "A - A" VESTIBULE CEILING 0 E PLAN SYMBOL EXTERIOR EXTERIOR CANOPY SOFFIT EXTERIOR DOOR NOTES: 1. METAL FRAMED GLASS ENTRY DOORS. 2. LOCATE JBOX ABOVE CEILING IN CART STORAGE AREA. 3. ALL CONDUIT SHALL CONTAIN PULL STRING FROM JBOX INTO DOOR OPENING. 4. REFERENCES: JCPenney OUTLINE SPECIFICATIONS, MASTER CONTRACT SPECIFICATIONS, DETAIL SECTIONS & CRITERIA PACKAGES. 7605 CUST. ENTRY DOOR RECESSED EMER. CONTACTS SCALE: NONE 03-23-06 NOTES: 1. GROUND DRAIN WIRE AT SOUND CONSOLE CNLY. 2. MAXIMUM 35 SPEAKERS ON CIRCUIT. 3. SPEAKERS COVER 900 SQ. FT. AVERAGE. 4. SPEAKERS ON MAXIMUM 30' -0" ON CENTER 5. VOLUME CONTROLS FOR FITTING ROOMS ON SPEAKER. LIMIT 12 VOL. CONTROLS PER HOMERUN. THERE ALSO SHALL BE A DEDICATED SOUND CABLE HOMERUN ON EACH FLOOR FOR REMOTE OFFICES. 6. SYSTEM DISTRIBUTION FOR INFORMATION AND ILLUSTRATION (COMPOSITE) 7. 2 CONDUCTOR #18 STRANDED, TWISTED SHIELD, JACKETED CABLE BY ELECT - CONTRACTOR FOR DIAL ACCESS PAGING INTERFACE. CONTRACTOR TO TERMINATE ON FOUR POST TERMINAL STRIP ON TELEPHONE BACKBOARD AND LEAVE 10 FEET OF SLACK BEHIND SOLND CONSOLE AND TAGGED AS "PAGING LOOP ". 8. FOREGROUND SPEAKERS ( & SUBWOOFERS) IN YOUNG MEN AND JUNIORS, SPECIAL FLUSH SPEAKERS FOR ASSIGNED "A" SIZE STORES AND LARGER ONLY. 9. SOUND CONSOLE FLOOR MOUNTED ON "A" STORES AND LARGER WALL MOUNTED RACK FOR "B" STORES AND SMALLER 10, FLUSH BOX BEHIND CONSOLE 12 "X12" X4" ON "A" STORES AND LARGER 8 "X8 "X4" ON "B" STORES AND SMALLER 11. REFERENCES: JCPenney MASTER CONTRACT SPECS. 16761 -C NOTES - PAGING AND MUSIC SYSTEM SCALE: NONE 07 -01 -03 NOTES: FSEE NOTE 1 I.G. BUS •L N BUILDING = STEEL COLUMN I.G. RECEPTACLES n • • • • n• n" • 2. REFERENCES: JCPenney DESIGN /MASTER CONTRACT SPECIFICATIONS, JCPenney CRITERIA PACKAGE AND STANDARD DETAILS. T- 8 0 MAXIMUM 4 I.G. RECEPTACLES NO COMMON GROUND PERMITTED WITH OTHER CIRCUITS NO COMMON NEUTRAL PERMITTED WITH OTHER CIRCUITS TYPICAL SALES FLOOR P.O.S. TERMINAL, WORKSTATION, AND PRINTER BRANCH CIRCUITING 1. 120/208 VOLT PANEL SERVING P.O.S. TERMINAL, WORKSTATION AND OTHER ELECTRONIC ITEMS. 16796 -G P. O.S. POWER - BRANCH CIRCUITING SCAL NONE 07 -01 -02 CONCRETE PANEL EXTERIOR INTERIOR HOLLOW METAL-- FRAME, GROUT SOUD SECTION "A "A" 3/4" CONDUIT W /PULL STRING BY E.C. (SEE NOTE 2) HINGE SIDE 1 _ 1 STRIKE SIDE 3/4" CONDU BY E.C. SURFACE MOUNTED 4" SQ. X 2 -1/8" DEEP JBOX W /COVER & WIRE CLAMP BY E.C. PULL STRING SURFACE MOUNTED 4" SQ. X 2 -1/8" DEEP JBOX W /COVER & WIRE CLAMP BY E.C. (SEE NOTE 3) SUSPENDED CEILING (WHERE APPLIES) HINGE SIDE SURFACE MOUNTED 4" SQ. X 2 -1/8" DEEP JBOX W /COVER Sc WIRE CLAMP BY E.G. 6 "(TYP.) F.F. I I F.F. INTER OR ELEVATION OF SINGLE INTERIOR ELEVATION OF DOUBLE PERIMETER EXIT AND /OR FIRE DOOR PERIMETER EXIT AND /OR FIRE DOORS NOTES: 1. ALL STORES 2, MOUNT CENTER OF JBOX 4" FROM STRIKE EDGE OF DOOR, WHEN CONDITIONS PROHIBIT, MOUNT AS CLOSE AS POSSIBLE TO STRIKE EDGE. 3. MOUNT CENTER OF J -BOX 11' -0" MIN. ABOVE FINISH FLOOR WHEN NO CEILING CONDITION EXISTS. 4. THE ABOVE CONDITIONS EXIST IN LOCATIONS WHERE THERE IS NO INTERIOR WALL FINISH, 5. REFERENCES: JCPenney OUTLINE SPECIFICATIONS, MASTER CONTRACT SPECIFICATIDNS, DESIGN SECTIONS AND CRITERIA PACKAGES. 17607 SURFACE MOUNTED DOOR CONTACTS ON UNFINISHED WALLS CENTER 3/4" CONDUIT W /PULL STRING ON DOOR OPENING BY E.C. 12" MAX. (TYP.) HINGE SIDE SCALE: NONE 03-23-06 WORKSTATION & PRINTER CABLES FURNISHED AND INSTALLED BY OTHERS at II HUBBELL IG5362 L_ GENERAL NOTES: CEILING STATION PANEL IN O.M.R. BY OTHERS t HUBBELL IG5362 EXTERIOR S OII• l i HINGE SIDE 1 1 STRIKE SIDE F.F. INTERIOR ELEVATION OF S NGLE PERIMETER EXIT AND /OR FIRE DOOR SEE NOTE 4 - 3/4" CONDUIT1` W /PULL STRING BY E.C. (SEE NOTE 2) CUTOUT VIEW FOR CLARIFICATIONS. HUBBELL 105361 RECEPTACLE FOR TIME CLOCK LOCATED ABOVE FINISHED CEILING OVER TIME CLOCK (TYP. 2 PLACES) CABLE FURNISHED AND INSTALLED BY OTHERS INSTALL 3/4" VERTICAL CONCEALED EMPTY CONDUIT TYP. FOR TIME CLOCK (SEE DETAIL 16793 -A) 1. REFER TO PLANS FOR QUANTITY AND EXACT LOCATIONS OF EQUIPMENT. 2. RACEWAYS, J -BOXES ARE FURNISHED AND INSTALLED BY E.G. 3. SIGNAL CABLES FURNISHED & INSTALLED BY OTHERS. 4. PROVIDE POWER AT THE LOCATIONS SHOWN ON PLANS FOR PRINTERS, WORKSTATION AND TIME CLOCKS. 5. MAXIMUM OF FOUR (4) OUTLETS ON EACH DEDICATED 120V/20A CIRCUIT FOR WORKSTATION. PROVIDE LOCKDOGS ON CIRCUIT BREAKER(S). 16793-B WORKSTATION & TIME CLOCK SIGNAL WIRING SCALE: NONE 07-01-02 COUNTER CASH REGISTER STAND jWALL OR COLUMN OUTLET) DETAIL "A" P.O.S. RJ -45 JACK AND WIREMOLD BOX BY DATATREND ONE 4 -PAIR GREEN TELEPHONE CABLE (10 FEET). TERMINATION BY JCP VENDOR. WALL OR COLUMN I REGISTER MULTI - OUTLET PLUG STRIP PROVIDED BY JCP I.G. RECEPTACLE P.0.5. DATA RECEPTACLE IN DRESS WIREMOLD BOX, WIRE AND JACK BY DATATREND P.O.S. RJ -45 RECEPTACLE ANY YELLOW CAT5E CABLE BY DATATREND TELEPHONE JACKS, BY OTHERS 1/2" GREENHELDS I.G. RECEPTACLE INSTALLED IN COUNTER WITH FLEX CONDUIT TO WALL /FLOOR BOX OUTLET. P.O.S. DATA RECEPTACLE INSTALLED IN COUNTER, CABLE EXTENDED FROM WALL /FLOOR BOX OWLET. TELEPHONE CABLE EXTENDED FROM WALL /FLOOR BOX OUTLET. (FOR PERMANENT INSTALLATION; NOT SEASONAL) REGISTER 3 -IN -1 P.V.C. BOX ON GRADE SLAB OR POKE -THRU ON UPPER LEVELS TOP FITTINGS FOR 3 GREENFIELDS TO SURFACE WIREMOLD DRESS BOXES ALL BY E.C. ORANGE I.G. RECEPTACLE COUNTER CASH REGISTER STAND 3 -in -1 P.V.C. BOX ON GRADE SLAB OR UPPER LEVELS, USING POKE -THRU DETAIL "C" REGISTER 3 -IN -ONE P.V.C. BOX ON GRADE SLAB OR POKE -THRU ON UPPER LEVELS. NOTES: 1. ALL WIRING, CONNECTIONS, AND DEVICES FOR POWER AND P.O.S. INSTALLATION BY E.C. 2. LOWER LEVEL FLOOR: FOR SINGLE P.O.S. TERMINAL LOCATIONS, THE I.G. POWER RECEPTACLE IS INSTALLED FLUSH IN FLOOR BOX. (EXCEPT DETAIL "B ") COUNTER CASH REGISTER STAND (FOR JEWELRY, COSMETICS AND CATALOG AREA REGISTERS) DETAIL "B" ONE OR TWO "CAT5E" YELLOW 4 -PAIR P.O.S. CABLES, SUPPLIED AND TERMINATED BY DATATREND. RAISED BASE 16796-H1 PO TERMINATIONS - SALES FLOOR SCALE NONE 07 -01 -02 PULL STRING IMO FLUSH MOUNTED 2" X 4" X 2 -1/8" DEEP JBOX W /METAL TELEPHONE COVER PLATE (BY E.G.) 4" SQ. X 2 -1/8" DEEP JBOX W /CDVER & WIRE CLAMP BY EC SECTION "B " - "B" HINGE SIDE 1 1 HINGE SIDE F.F. 3/4" CONDUIT W /PULL STRING BY E.C. CTA DEVICE (BY OTHERS) CABLES L FURNISHED AND INSTALLED BY OTHERS T A. DEVICE - BY OTHERS (TYP. 2 PLACES) SEE 16793 -A FOR BOX DETAILS INTERIOR ELEVATION OF DOUBLE PERIMETER EXIT AND /OR FIRE DOORS NOTES: 1. ALL STORES 2. MOUNT CENTER OF JBOX 4" FROM STRIKE EDGE OF DOOR. WHEN CONDITIONS PROHIBIT, MOUNT AS CLOSE AS POSSIBLE TO STRIKE EDGE. 3. THE ABOVE CONDITIONS EXIST IN LOCATIONS WHERE THERE IS INTERIOR WALL FINISH. 4. DOOR CONFIGURATIONS AND /OR WALL CONDITIONS MAY VARY. 5. REFERENCES: JCPenney OUTLINE SPECIFICATIONS, MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 1 7607- A rk SURFACE MOUNTED DOOR CONTACTS ON FINISHED WALLS SCALE: NONE T.C. #2 6 "(TYP.) CEILING CENTER 3/4" CONDUIT W /PULL STRING ON DOOR OPENING, BY E.C. r TO P.A.W.S. WORKSTATION (BY OTHERS) TIM SHEET WALL SOFFIT 03 -16 -07 ECTRICAL A. SELECT ONLY THE APPLICABLE DETAI B. VERIFY LATEST DETAILS ON JC PENN EY'S BUZZSAW SITE. ,PJ E 0 (- 0 0 v 0 � o- a r•0 0 (1) - (NI ro a q CO to r-) 0 a v 0 CV 0 o, � 00 co I T v c-3 4 d' LL/ E W 1 N o C J 0 (7) t f � m a a W _ o m o xm NOV 1 2 2007 2 • CV ICC to Lo C35CT) CI d d x p F- '4 ' ' N C'1 N Q- LL ETSI G\, NOTES L5 SPECIFIC TO THE PROJECT. NOV 27 2007 E E S i'V { I GEN. .1 E N JrE G: 10706XXX10706010 10706010_E702.dwg 11112/07 04:00:12 PM COPYRIGHT 2007 CALLISON ISSUED / REVISED PERMIT / PRICING ISSUE 11.09.07 PERMIT ISSUE ELECTRICAL DETAILS E702 DATE 2325 North Akard Street CALLISON INTRUSION 4 "X4" (2 -1/8" DEEP) 3 itt. I, *4 I oR E.C. SHALL INSTALL FIRE -LITE PN 10103. (PROVIDED BY ADT) OR E.C. SHALL FURNISH & INSTALL THREE GANG ELECTRICAL BOX WITH MIN. DEPTH OF 2.188" HORIZONTAL, CONDUIT MUST ENTER TOP OF BOX. a ti 12 4g" AFE 3/4" CONDUIT W /PULL STRING & BUSHING STUBBED 6" ABOVE CEILING IN CART STORAGE AREA (BY E.C.) 40 GRAPH BISp r 48'4 AEF :R IQR NOTES: 1. ALL STORES 2. COORDINATE LOCATION OF JBOXES WITH DOOR AND ARCHITECTURAL DETAILS. (JBOXES BY E.C.) 3. INTRUSION JBOX PLACEMENT SHALL BE 48" A.F.F. ON WALL, WITHIN VESTIBULE NEAR INTERIOR DOORS. 4. FIRE JBOX PLACEMENT SHALL BE 48" A.F.F. ON WALL, WITHIN VESTIBULE NEAR EXTERIOR DOORS. 5. 4 "X4" JBOXES SHALL BE FLUSH MOUNTED WITHOUT COVERS & CENTERED BETWEEN GRAPHICS DISPLAY & DOOR FRAMES. 6. ADT TO SECURE KEYPADS TO JBOXES. 7. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. FIRE SEE 17ouo INTRUSION ALARM KEYPAD SCALE: NONE Top of Joist Looking up from Floor Level NOTE: 1. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. Wire Clamp •"X4 "X 2-1/8" Deep JBox, No Cover, Furnished By EC. 17621-A BAR SCALE NONE JO IST MOUNTED HORN /STROBE 03 -23 -06 STUB ABOVE CEILING TO ACCESSIBLE SPACE BUSHING FURNISHED BY ELECTRICAL CONTRACTOR 4" SQ, DEEP BOX FURNISHED BY ELECTRICAL CONTRACTOR C)7:/ e a /o coo 2 c> ` 00 0000 0000 0000 00 0 0 0} 0 (D0 0 =0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 Q o �a � C=3 = =/ CONTROL MODULES SUPPLIED AND WIRED BY THE IAC. WIRE FROM THE CONTROL MODULE TO THE ELEVATOR C❑NTR ❑LER IS BY THE ELEVATOR CONTRACTOR ALL WIRING IS TO BE LOW VOLTAGE POWER LIMITED TO 28 VOLTS 1/2 AMP, NOTE: 1. ALL SPUCES TO BE MADE PER NFPA 72. 2. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 3. CONDUIT AND BOXES BY ELECTRICAL CONTRACTOR. 07 -12 -07 17630 CONTROL MODULE FOR FIRE COMMUNICATOR SCALE: NONE 01 -01 -04 EXTERIOR ELEVATION AT KNOX BOX PLAN VIEW AT BUILDING EXTERIOR .4 SEE NOTE # • 4 4 NOTES: 1. ALL STORES 2. KNOX BOX LOCATION AND QUANTITY, SHALL BE DETERMINED BY LOCAL AFIJ. 3. KNOX BOX FURNISHED AND INSTALLED BY JCPENNEY. 4. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 4 A JBOX LOCATED ll � 6" ABOVE CEILING d �II 4 a I � SEE PLAN VIEW SURFACE MOUNTED 4" SQ. X 2 --1/8" DEEP JBOX W /COVER & WIRE CLAMP BY E.C. 3/4" CONDUIT BY E.C. 4 EXTERIOR SURFACE MOUNTED 4" SQ. X 2 -1/8" DEEP JBOX W /COVER BY E.C. SECTION "A " - "A" FINISHED WALL STUB 3/4" CONDUIT W /PULL STRING AT KNOX LOCATION BY E.C. 17614 KNOSCALE: X NONE BOX INTRUSION ALARM SYSTEM 03 -23 -06 • Ceiling Tile! •'• :cut away .: Wire Clamp Ceiling Tile Grid 4'X4" Backbox 2 1/8' In Deep Furnished by Electrical Contractor No Cover / Ceiling Grid . Hanger Wire •. Ceiling Tile Ceiling Tile VIEW: Looking upwarc NOTE: 1. ALL SPLICES TO BE MADE PER NEC 760. 2. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 3. CONDUIT AND BOXES BY ELECTRICAL CONTRACTOR. toward Ceiling. 1-7621-B CEILING MOUNTED HORN /STROBE SCALE: N ONE 12 -15 -06 Grade Level 48' ± A.F.F. �I T -I ULL STRING (By E.C.) Stub 3/4" Conduit W /Bushing 6" above ceiling into accessible space. (By E.C.) Monitor module By IAC 4" Sq. X 2 -1/8" Deep JBox, NO COVER (BY E.C.) Post Indicator Valve (By Mechanical contractor) PIV Switch By Sprinkler Contractor 1/2" Sealtite Conduit (By E.C.) 4" Sq. Weather proof JBox W /Cover (By E.C.) 3/4" - 14 ga. THAW conduit (min.) (By E.C.) NOTES: 1. ALL STORES. 2. WIRE BETWEEN MONITOR MODULE & PIV SWITCH MUST BE THHV( OR EQUAL 14AWG (BY E.C.). 3. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. OPEN POST INDICATOR VALVE -mint., SCALE: NONE 12 -15 -06 Mount Box with Beam Clamp Do not Penetrate Roof Deck Top of Joist Bottom of Joist Backbox 3 1/2' Octagon Furnished by Electrical Contractor Romex Connector i NOTE: 1. ALL SPLICES TO BE MADE PER NEC 760 2. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 3. CONDUIT AND BOXES BY ELECTRICAL CONTRACTOR. 17628 SMOKE DETECTOR MOUNTING DETAIL BAR JOIST SCALE: NONE 12 -15 -06 Ceiling Stub 3/4" above ceiling - to accessible space. Bushing & Conduit Furnished By Electrical Contractor Horn Strobe 3/4' Conduit Manual Pull 0 0 0 0 Pull String NOTE: 1. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 4'X4`X2 -1/8' Deep JBox, No Cover Flush Mounted, 82' AFF C By E,C, Horn /Strobe box not required when manual pull station Is used only. 4'X4'X2 -1/8" Deep JBox, No Cover Flush Mounted, 48' AFT By E.C. 17o‘i MANUAL PULL AT DOOR O� TIO SANDAL SCALE: NONE 0 -23- 17628A SMOKE DETECTOR CEI MOUNTED SCALE: NONE 12 -15 -06 cc w c ce Q- N E w a 0 -) (O 0. E 4 c `� O o co Qom v r' p Q N U C7) o) co CO I (0 C7a m p0 ` E wai 3 m W z Q 9 Q >CO W - n aa NOV 1 2 2007 2 0 J J U 0 rn C (0 M , D'' " er NOV 2 7 Z007 PEI i L;bi`ti G: 10706xxx1070601010706010 3703.dwg 11/12/07 c3:38:57 PM COPYRIGHT 2007 CALLISON U isra, ISSUED / REVISED t, 0 CNA DATE PERMIT / PRICING ISSUE 11.09.07 PERMIT ISSUE ELECTRICAL DETAILS E703 Hanger Wire If IPIIIIMIIIIIPPPPPP' Ceiling Grid Required For T �► Hanger Wire Bar, Bottom Ceiling Tile - Top of of Joist lir Joist . Ceiling Tile Grid Connector Backbox 3 1/2" Backbox Furnished by Electrical Contractor T Bar ��•r �• Hanger • Ceiling Tile . Ceiling Tile ' . Ceiling Tile NOTE: 1. ALL SPLICES TO BE MADE PER NEC -760 2. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 3. CONDUIT AND BOXES BY ELECTRICAL CONTRACTOR. INTRUSION 4 "X4" (2 -1/8" DEEP) 3 itt. I, *4 I oR E.C. SHALL INSTALL FIRE -LITE PN 10103. (PROVIDED BY ADT) OR E.C. SHALL FURNISH & INSTALL THREE GANG ELECTRICAL BOX WITH MIN. DEPTH OF 2.188" HORIZONTAL, CONDUIT MUST ENTER TOP OF BOX. a ti 12 4g" AFE 3/4" CONDUIT W /PULL STRING & BUSHING STUBBED 6" ABOVE CEILING IN CART STORAGE AREA (BY E.C.) 40 GRAPH BISp r 48'4 AEF :R IQR NOTES: 1. ALL STORES 2. COORDINATE LOCATION OF JBOXES WITH DOOR AND ARCHITECTURAL DETAILS. (JBOXES BY E.C.) 3. INTRUSION JBOX PLACEMENT SHALL BE 48" A.F.F. ON WALL, WITHIN VESTIBULE NEAR INTERIOR DOORS. 4. FIRE JBOX PLACEMENT SHALL BE 48" A.F.F. ON WALL, WITHIN VESTIBULE NEAR EXTERIOR DOORS. 5. 4 "X4" JBOXES SHALL BE FLUSH MOUNTED WITHOUT COVERS & CENTERED BETWEEN GRAPHICS DISPLAY & DOOR FRAMES. 6. ADT TO SECURE KEYPADS TO JBOXES. 7. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. FIRE SEE 17ouo INTRUSION ALARM KEYPAD SCALE: NONE Top of Joist Looking up from Floor Level NOTE: 1. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. Wire Clamp •"X4 "X 2-1/8" Deep JBox, No Cover, Furnished By EC. 17621-A BAR SCALE NONE JO IST MOUNTED HORN /STROBE 03 -23 -06 STUB ABOVE CEILING TO ACCESSIBLE SPACE BUSHING FURNISHED BY ELECTRICAL CONTRACTOR 4" SQ, DEEP BOX FURNISHED BY ELECTRICAL CONTRACTOR C)7:/ e a /o coo 2 c> ` 00 0000 0000 0000 00 0 0 0} 0 (D0 0 =0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 Q o �a � C=3 = =/ CONTROL MODULES SUPPLIED AND WIRED BY THE IAC. WIRE FROM THE CONTROL MODULE TO THE ELEVATOR C❑NTR ❑LER IS BY THE ELEVATOR CONTRACTOR ALL WIRING IS TO BE LOW VOLTAGE POWER LIMITED TO 28 VOLTS 1/2 AMP, NOTE: 1. ALL SPUCES TO BE MADE PER NFPA 72. 2. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 3. CONDUIT AND BOXES BY ELECTRICAL CONTRACTOR. 07 -12 -07 17630 CONTROL MODULE FOR FIRE COMMUNICATOR SCALE: NONE 01 -01 -04 EXTERIOR ELEVATION AT KNOX BOX PLAN VIEW AT BUILDING EXTERIOR .4 SEE NOTE # • 4 4 NOTES: 1. ALL STORES 2. KNOX BOX LOCATION AND QUANTITY, SHALL BE DETERMINED BY LOCAL AFIJ. 3. KNOX BOX FURNISHED AND INSTALLED BY JCPENNEY. 4. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 4 A JBOX LOCATED ll � 6" ABOVE CEILING d �II 4 a I � SEE PLAN VIEW SURFACE MOUNTED 4" SQ. X 2 --1/8" DEEP JBOX W /COVER & WIRE CLAMP BY E.C. 3/4" CONDUIT BY E.C. 4 EXTERIOR SURFACE MOUNTED 4" SQ. X 2 -1/8" DEEP JBOX W /COVER BY E.C. SECTION "A " - "A" FINISHED WALL STUB 3/4" CONDUIT W /PULL STRING AT KNOX LOCATION BY E.C. 17614 KNOSCALE: X NONE BOX INTRUSION ALARM SYSTEM 03 -23 -06 • Ceiling Tile! •'• :cut away .: Wire Clamp Ceiling Tile Grid 4'X4" Backbox 2 1/8' In Deep Furnished by Electrical Contractor No Cover / Ceiling Grid . Hanger Wire •. Ceiling Tile Ceiling Tile VIEW: Looking upwarc NOTE: 1. ALL SPLICES TO BE MADE PER NEC 760. 2. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 3. CONDUIT AND BOXES BY ELECTRICAL CONTRACTOR. toward Ceiling. 1-7621-B CEILING MOUNTED HORN /STROBE SCALE: N ONE 12 -15 -06 Grade Level 48' ± A.F.F. �I T -I ULL STRING (By E.C.) Stub 3/4" Conduit W /Bushing 6" above ceiling into accessible space. (By E.C.) Monitor module By IAC 4" Sq. X 2 -1/8" Deep JBox, NO COVER (BY E.C.) Post Indicator Valve (By Mechanical contractor) PIV Switch By Sprinkler Contractor 1/2" Sealtite Conduit (By E.C.) 4" Sq. Weather proof JBox W /Cover (By E.C.) 3/4" - 14 ga. THAW conduit (min.) (By E.C.) NOTES: 1. ALL STORES. 2. WIRE BETWEEN MONITOR MODULE & PIV SWITCH MUST BE THHV( OR EQUAL 14AWG (BY E.C.). 3. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. OPEN POST INDICATOR VALVE -mint., SCALE: NONE 12 -15 -06 Mount Box with Beam Clamp Do not Penetrate Roof Deck Top of Joist Bottom of Joist Backbox 3 1/2' Octagon Furnished by Electrical Contractor Romex Connector i NOTE: 1. ALL SPLICES TO BE MADE PER NEC 760 2. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 3. CONDUIT AND BOXES BY ELECTRICAL CONTRACTOR. 17628 SMOKE DETECTOR MOUNTING DETAIL BAR JOIST SCALE: NONE 12 -15 -06 Ceiling Stub 3/4" above ceiling - to accessible space. Bushing & Conduit Furnished By Electrical Contractor Horn Strobe 3/4' Conduit Manual Pull 0 0 0 0 Pull String NOTE: 1. REFERENCES: JCPenney MASTER CONTRACT SPECIFICATIONS, DESIGN SECTIONS AND CRITERIA PACKAGES. 4'X4`X2 -1/8' Deep JBox, No Cover Flush Mounted, 82' AFF C By E,C, Horn /Strobe box not required when manual pull station Is used only. 4'X4'X2 -1/8" Deep JBox, No Cover Flush Mounted, 48' AFT By E.C. 17o‘i MANUAL PULL AT DOOR O� TIO SANDAL SCALE: NONE 0 -23- 17628A SMOKE DETECTOR CEI MOUNTED SCALE: NONE 12 -15 -06 cc w c ce Q- N E w a 0 -) (O 0. E 4 c `� O o co Qom v r' p Q N U C7) o) co CO I (0 C7a m p0 ` E wai 3 m W z Q 9 Q >CO W - n aa NOV 1 2 2007 2 0 J J U 0 rn C (0 M , D'' " er NOV 2 7 Z007 PEI i L;bi`ti G: 10706xxx1070601010706010 3703.dwg 11/12/07 c3:38:57 PM COPYRIGHT 2007 CALLISON U isra, ISSUED / REVISED t, 0 CNA DATE PERMIT / PRICING ISSUE 11.09.07 PERMIT ISSUE ELECTRICAL DETAILS E703 TO COVE STRIP LIGHTS INSIDE FEATURE WALL STUB UP COLUMN OR FULL HEIGHT WALL J--BOX AT 8" ABOVE FINISHED CEILING HOMERUN TO PANE TRENCH FLOOR TO NEAREST COLUMN OR FULL HEEGHT WALL J -BOX AT 10' -0" ABOVE FINISHED FLOOR CEILING TO COVE STRIP LIGHTS INSIDE FEATURE WALL WIRING DETAIL - PARTIAL HEIGHT FEATURE WALL SCALE: NONE CD 3/4" HOLE ON CENTER CONDUIT /CABLE EXIT 19" A 1/2" CONDUIT STUB UP FLUSH WITH FINISHED FLOOR T.F. FC 1'- EkTRANCE VEST — EC TO DRILL 1" HOLE IN 3X3 ANGLE IRON FOR CONDUITS STORE SCALE: 3 " =1' -0" POWER PACK HARDWIRED JUST ABOVE ACCESSIBLE /-- FINISHED CEILING I 9ao oaTti POWER PACK 3/4' CON D 1/2" CONDUIT STUB UP FLUSH WITH FINISHED FLOOR ENTER 19" =XIT .F. FOR EAS SYSTEM DETAIL WIRING DETAIL - FULL HEIGHT FEATURE WALL omm 17 rani\ IMAM II�II IL ! _ � l 1/2" CONDUIT- 0' SCALE: NONE POWER PACK HARDWIRED JUST ABOVE ACCESSIBLE/ FINISHED CEILING 120VAC DEDICATED C? 1/2" CONDUIT NOT TO EXCEED 45' FINISHED CEILING FINISHED FLOOR \ 1:1 3 " =1-0" STUDS 1900 BOX WITH 1 GANG PLASTER RINGS NOTE: FOR HORIZONTALLY MOUNTED RECEPTACLES, ALLOW 6" SPACING BETWEEN DEVICES. WIRING DEVICE MOUNTING DETAIL MOUNTING BRACKET FLOOR 00 CD LLI 4 CL [Y_ 4y O o C)U U h` W . L U � � LL E 0 U c 0 1:j rn Q. q) - -4- V) P 4) CO tl) V) O C a) O • NC V 000 E V (n C e Q 6 E3 0 a) 2cc r z O. . � o » co w N cL Li NOV 1 2 2007 • 2 0 U, 46 22 —I 07 N - 10 10 0 z a(8 J - -4. 5 CD ct N CV O SV Q— L.L. f ..' NOV 2 7 2007 �r c�.N ER G: 10706xxx1070601010706010 _E704.dwg 11/12/07 0:60:16 PM COPYRIGHT 2007 CALLISON ISSUED / REVISED DATE PERMIT / PRICING ISSUE 11.09.07 PERMIT ISSUE ELECTRICAL DETAILS E704