Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-256 - WESTFIELD SOUTHCENTER MALL - PANDA EXPRESS
PANDA EXPRESS 2600 SOUTHCENTER MALL FC -10 M07 -256 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: doc: IMC -10/06 City►f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2600 SOUTHCENTER MALL TUKW MECHANICAL PERMIT PANDA EXPRESS 2600 SOUTHCENTER MALL FC -10 , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: CHARLES LEA Address: 1683 WALNUT GROVE AV , ROSEMEAD CA Contractor: Name: AIRE PRO INC Address: 1112 S 344TH ST STE 303 , FEDERAL WAY Contractor License No: AIREPI *032RU DESCRIPTION OF WORK: (2) NEW TYPE I KITCHEN HOOD SYSTEM, (1) 5 -TON A/C AND WALK -IN COOLER AND FREEZER Value of Mechanical: $45,000.00 Type of Fire Protection: SPRINKLER/AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 1 1 0 2 0 0 * *continued on next page ** M07 -256 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 626 280 -9188 Phone: 253 942 -7028 Expiration Date: 03/18/2010 M07 -256 05/01/2008 06/09/2008 Fees Collected: $672.95 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 1 Diffuser 0 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 05 -01 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e - ed this permit and know the same to be true and correct. All provisions of law and ordinance: governing this work will be complied t whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: I - t 5 J • 1::& I doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -256 Issue Date: 05/01/2008 Permit Expires On: 06/09/2008 Date: 04.7i 1,1 ) Date: 5/ /z,„,98 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende or abandoned for a period of 180 days from the last inspection. M07 - 256 Printed: 05 -01 -2008 Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Tenant: PANDA EXPRESS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 - 256 Status: ISSUED Applied Date: 11/28/2007 Issue Date: 05/01/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire- extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire- extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 13: An approved automatic fire - extinguishing system is required for this project. 14: Local U.L. central station supervision is required. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire doc: Cond -10/06 M07 -256 Printed: 05 -01 -2008 �/ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http :• / /www.ci.tukwila.wa.us Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 16: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 17: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -256 Printed: 05 -01 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: I s � �'�'-- Date: ' / 6 Print Name: doc: Cond -10/06 M07 -256 Printed: 05-01 -2008 E -Mail Address: Company Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ht4):/lwww.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 5 se..ih Ga►Tw Tenant Name: PANDA gXppP-ss Property Owners Name: Ms MA. /., I r�• n c • Mailing Address: / /COI i/a. / qth Fk CONTACT PERSON -- who do we contact when your permit is ready to be issued Name:_ g Wt5 Lam+- pay Telephone:_ Mailing Address:_ /I e3 /4)191,1V T i 15i J I) city Contact Person: Day Telephone: Fax Number: Contractor Registration Number: •<-4; I Assn # ;.►4t � rill„ I ch; atm..) . A-R LA • 40.,4 CAL ,e- Pi) lNdn Contact Person: Ci/j _pabs e Leal Q:Mpplications\Forms- Applications On Line 13 -2006 Permit Application.doc Revised: 9 - 2006 bh 6 r "o,sy E -Mail Address: 1, 4 44 44,C. • n c f Ut • City City Plumbing/Gas Permit No: ® " Public Works Permit No. King Co Assessor's Tax No.: (z 7 Z'O — 00 ( 0 Suite Number: FC —/O Floor: New Tenant: E ' Yes City 44 9/45 e.� 4 State Zip nbel1 _ > ' a // r Fax Number:_ 6Z4 2 ' yl er State 2 nel ❑..No 9,2425 Zip Zip —a L. GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Pluni and Gas Piping (pg 5)) Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record State Zip 9 Day Telephone: .•/ 0/6, 27.. 3 6 Fax Number:_4' / 3303 ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record . 30/ KoSG4464 Ch 9/770 City State Zip Day Telephone:`62) 2./4 0 _ q/8 6 Fax Number: ((,? /,) 2 So 9 / B cj Page 1 of 6 G ow errs L. .S1 ZG BUILDING PERMIT: INFORMATION 206 - 4313 Valuation of Project (contractor's bid price): $ /00/< Scope of Work (please provide detailed information): / 74696 r6a /4 1 C Will there be new rack storage? t ....Yes ,Zr. No If yes, a separate permit and plan ` s . nine will be required. p., , lro 5k/47 - 1A' 674. / ` C72 ~ hs1 A.) I' vide All Busldtng Areas in Square Footage Below st 3 [ ase tructure age; ached:a ie etacl ached ac aver+ cov Lot Area (sq ft): 44-5 nor o,lesi Addition to Existing Structure B CRLst s Floor area of accessory dwelling: PLANNING DIVISION: Single family building footprint • ea of the foundation of all structures, plus any decks over 18 in t es and overhangs greater than 18 inches) `For an Accessory dwelling, ovide the following: Floor area of principal dwelling: *Provide docum- : tion that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking S s Provided: Standard: Compact: Handicap: P`✓M.s t Will there be a ch; :e in use? ❑ Yes A No If `ryes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) • Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.......Yes X No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: Applications\Fotms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Existing Building Valuation: $ PAJVQA P"Meess) fro � Page 2 of 6 YhA Unit Type: Qty Unit Type: Qty Unit Type: .. Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper / 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler / Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct / Thermostat / / 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Z Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <l0,000 CFM ` Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION = 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Stale Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please provide detailed information): AIRAI Z — / ,/7Zf/i 4-40a2. SpreV1 Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....� Replacement .... ❑ Fuel Type: Electric ❑ - Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q:1AppliationaWomu- Applications On Line\3.2006 - Permit Application.doc Revised: 9 - 2006 bh Page 4 of 6 PUBLIC WORKS PERMIT INFORMATION — 206 -433 -0179 Scope of Work (please provide detailed information): PA No A- £x pp es s) Water District ❑ ...Tukwila ❑ . ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑...Se Septic System: ❑ On -site Septic System — For on -site septic Water District #125 Call before you Dig: 1- 800 - 424-5555 Ple - e refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ ...V : Vue ❑ .. Renton Availability Provided ❑ .. Highline stem, provide 2 copies of a current sep Submitted with Application (mark boxes which t ply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 3 ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geo El ...Bond ❑ .. Insurance ❑ .. Eas- ent(s) ❑ .. Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protec Iirigati ❑ ...Permanent Water Meter S. Of ❑ ...Temporary Water Meter e " ❑ ...Water Only Meter Siz' ❑ ...Sewer Main Extensi Public ❑ ...Water Main Exten an Public FINANCE INFORM TION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: cubic yards cubic yards Domes ' Water Q:Wpplications\Forms- Applications On Linc\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Abandon Septic Tank .. Curb Cut .. Pavement Cut ❑ .. Looped Fire Line WO # WO # WO # Private Private Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment ical Report tenance Agreement(s) .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance Work in Flood Zone ❑ torm Drainage ❑...Dedu Water Meter Size Day Telephone: City City ❑..Ren .. Seattle esign approved by King County Health Department. ❑ ... Traffic Impact Analysis El ...Hold Harmless — (SAO) El ...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding f) State Day Telephone: State Zip Zip Page 3 of 6 PERMIT APPLICATION NOTES — Applicable all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. • Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ER OR AUTHOf ED AGENT: Signature: Date: li / y A0O7 Day Telephone: 3 /ey 3(0¢4 x 244 Print Name: ,Am :A itt I dick; / Mailing Address: ht .as,.�� A . A.)4 J,, s 4223 AA # c - /oro Date Application Expires: 01401- Date Application Accepted: Q:WpplicationsTonns- Applications On Line\ -2006 - Permit Application.doe Revised: 9 -2006 bh City eh/ P. Sta f — State Zip f"E� Staff Initials: Page 6 of 6 Fixture Type. Qty :.Fixtu Type... Qty -, '.: Fixture -Type: Qty ` Fixture Typ Bathtub or combination bath/shower Drinking fountain or wa cooler (per head) ash fountain Gas piping outlets 4 Bidet Clothes washer, domestic Dental unit, cuspidor Food -waste grinder, commercial Floor drain fl m® Shower, singl - read trap Re ptor, indirect was Urinals Dishwasher, domestic, with independent drain Lavatory Water Cl. t Building sewer or trailer sewer Rain w r system — per drain side building) Water heater . ' d/or vent r / Additional medical gas inlets/outlets — six or more park Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Re • or alteration of water p' • g and/or water treating •uipment Repair or alterati r of drainage or ven piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION -.206- 431 -3670 *10 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contract Valuation of Gas Piping work (contract Scope of Work (please provide detailed in Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: ate t ype of plumbin fixtures and/or gas piping outlets b installed and the quantity below: State Zip 001 2 - 101M Sewer: Q: Applications\Forms- Applications On Line13 -2006 - Permit Appliation.doc Revised: 9-2006 bh Page 5 of 6 Initials: User ID: �,..•• arrRrm_nn RECEIPT NO: R08 - 01441 JEM 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: WILCOX CONSTRUCTION, INC. SET RECEIPT SET ID: 0501 SET NAME: PANDA EXPRESS SET TRANSACTIONS: Set Member Amount M07 -256 544.36 PG07 -318 324.00 TOTAL: 868.36 TRANSACTION LIST: Type Method Description Amount Payment Check 073994 868.36 TOTAL: 868.36 ACCOUNT ITEM LIST: Description GAS - NONRES MECHANICAL - NONRES PLUMBING - NONRES Account Code Current Pmts 000/322.100 95.00 000/322.100 544.36 000/322.100 229.00 TOTAL: 868.36 Payment Date: 05/01/2008 Total Payment: 868.36 1870 05/01 9711 TOTAL 868,36 RECEIPT NO: R07 -02599 Initials: JEM User ID: 1165 Payment Check 833 ACCOUNT ITEM LIST: Description Payee: CAL ARC DESIGN STUDIO, INC. SET ID: S000000903 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us D07 -437 800.79 EL07 -723 102.50 M07 -256 128.59 PG07 -318 73.25 TOTAL: 1,105.13 TRANSACTION LIST: Type Method Description Amount ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Account Code Current Pmts 000.345.832.00.0 102.50 000/345.830 1,002.63 TOTAL: 1,105.13 Payment Date: 11/28/2007 Total Payment: 1,105.13 1,105.13 1,105.13 5432 11/28 9710 TOTAL 1105.13 Project: Project: % eXr reSS Type of Inspection: %„ r I Address: 2400 FC to Mil Date Called: Date Wanted: 2 /--- p.m. Special Instructions: Requester: Phone No: Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IiQ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 ® Approved per applicable codes. COMMENTS: r {ul f• 1 t r of . �/w f c vr pt 1G (r1-K Inspector: „....,•,4„,.,,,„..,_.„....... INSPECTION RECORD r1o2-,2S'G Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Retain a copy RECORD with 'lG`7-256 INSPECTION NO. . pY permit I PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proje D Approved per applicable codes. Address: (9a // • Special Instructions: Type of n ection: Date Called: D Wanted: 4.5 Requester: Ph No• o� fir? -/1/43 Corrections required prior to approval. COMMENTS: Not R e.c d 'Inspector: Date: �' r f $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 14 - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Address: Type Inspection: Date Call d^ A A Ak a.m. p.m. Date Wanted: —7 •1 C 3 ( Requester: Phone No: Proje 4 ■�.O R SA 7600 M Special Instructions: OMMENTS: kik Cf—V1 De (kg‘ Vr- c-N Approved per applicable codes. ❑ Corrections required prior to approval. Inspector: Date ' )o, -76 I PERMIT NO. fJ $60.00 REINSPECTION FEE R QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit ifilg7-4. I PERMIT NO. 1 (206)431 -3670 7 12 e � Type of Inspection: 111 Date Called: ____ Project: Address Special Instructions: Date Wanted: l 74/ p Requester: Phone No: Corrections run,th- I A pproved per applicable codes. 11 ,4 approval. COMMENTS: OK .C f o ,,,, r C y ri cier- b 4- o ' to 1 lnspector: D $60.p paid 3 ( Date: 74 447 I EINSPECTION FEE REQUIRED. Prior to inspection, fee must be 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: I 1 INSPECTION NO. PEWIT NO. CITY OF TUKWILA BUILDING DIVISION �P 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project: Type of Inspection: 7. IL/'4 tpres per 1 -s 1- Address: Date Called: V oc, - FG i o lied Special Instructions: Approved per applicable codes. 'Inspector: INSPECTION RECORD Retain a copy with permit Date Wanted: Requester: h Date: 11 $60.00 R�tFISPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: a.m. Phone No: 396 0 6 2 S Corrections required prior to approval. COMMENTS: p`T r j e-% rif5Sc/e- 46 e'st T-sf 2- 057' t is tyff INSPECTION RECORD Retain a copy with permit El Approved per applicable codes. 1 /914 7-z54 I INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION PE IT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( -3670 Project: Address: ,OG 41 Special Instructions: Corrections required prior to approval. IJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Rpe inf Ali. . II INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)431 -3670 Project: /9y P./kW Type of spection: - � ddrefs• Date Called: ,2 cOb 4441/ Special Instructions: ( Date W nted: Requester: Pte6z WL,4C P'et o<<. INSPECTION RECORD Retain a copy with permit 131/ J.."„_, Pk / / Jo( & ';vi h k -`G -or $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. a. Approved per applicable codes. fJ Corrections required prior to approval. COMMENTS: / ?f 'Inspector: Date: I I I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Project: And& 7Cy /re55 Address: 2620/f4y0 C1#4// Special Instructions: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 36 Type of Inspection: Date Called: Date Wanted: Requester: ye- 70 a. El Corrections required prior to approval. El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. pint Nn COMMENTS: ..)4 r" Type of Inspection: c 74 H;181 6 1„. i plea - ok ..,,, -( — / , pii el c____ 0 Con ct Peron: . Spedal Instructions: Permits: Phone No.: 1 - 70 c A - t g-€1 5 1•(Zo b‹,. (N) ::)- Tt Le' C e..._ ..- i dier L. — 0‹,. Pir P‘ied2) CA5-e 0)k} /4• ; ki r-^"Vjeg Eit- f5e 5// Project: (--) 1 11)1JDP • ..)4 r" Type of Inspection: c 74 H;181 6 1„. i Address: 66 Suite #: 1- ..,,, -( — / , pii el c____ 0 Con ct Peron: 1 Spedal Instructions: Permits: Phone No.: Needs Shift Inspection: Sprinklers: (.....-- t Are Alarm: Y Hood & Duct: Y Monitor: 4 pv, rd 1 GI fj Pre-Fire: A) Permits: Occupancy Type: INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila. Wa. 98188 206-57S- Word/Inspection Record Form.Doc 1/13/06 / o7 PERMIT NUMBERS Corrections required prior to approval. I Inspector: A Date: 742 //e8 Hrs.: I Ft $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 = ltr azan GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING Rc^E'nSTRUCTION TESTING & INSPECTION July 21, 2008 , ja i 2 5 2608 KA No. 066 -08153 COMMTV DEVELOPP I66ENT Ms. Michelle Jennings Aire Pro 2921 Meridian Ave. E. Edgewood, WA 98371 RE: Special Inspection Panda Express Tukwila, WA Dear Ms. Jennings, In accordance with your request and authorization, our firm performed special inspections for the above - referenced project. The inspections were performed by our inspectors from June 11 through June 16, 2008. Copies our inspector's field reports are attached. Unless otherwise indicated, the structural activities noted on the attached daily field reports were in accordance with the approved project plans and specifications. A guarantee that the contractor has necessarily constructed the structure in full accord with the plans and specifications is neither intended nor implied. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC Kathryn E. (Tordon Project Manager Puyallup Division CC: City of Tukwila & ASSOCIATES, INC. Offices Serving The Western United States 922 Valley Avenue NW Suite 101 • Puyallup, Washington 98371 • (253) 939 -2500 • Fax: (253) 939 -2556 08153 DFR IKraz ari B,ASSOCIATES, INC. DATE: 6-11 -08 GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION PROJECT #: 066 -08153 PROJECT: Panda Express KRAZAN PROJECT MANAGER K.E.G. WEATHER Cloudy To the bes S - endent/Rep tative: Structural Steel 1) Met with the contractor to verify inspection and review plans. 3) Weld should be repaired and re- inspected upon completion for final acceptance. Offices Serving the Western United States FIELD REPORT NO.: 8153DFR061108 -gn CONTRACTOR: Wilcox Construction PERMIT NO: M07 -256 INSPECTOR George Naill / Joe Bauduin LOCATION: South Center Mall JURISDICTION: City of Tukwila Arrived on site as requested by the contractor to perform Structural Steel inspection in conformance to project plans and specs. 2) Performed visual inspection of Grease Duct welded connection for kitchen hood to roof penetration. Inspection was performed per section 506.3.3.1 IBC mechanical code 2006 Revealed welding to be insufficient with multiple pin holes in the welds visible. knowledge, the above WAS ❑ / WAS NOT ® performed in accordance with the approved plans, specifications, and regulatory requireme* Technician George Naill / Joe Baudin Temp: 50 F Equipment/Asset Number(s): Form 1501 r.2 Effective Date: 12 -20 -07 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. ' - i i az 11 & Associates, Inc. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE: V/44 PROJECT O - 0 8/X,3 PROJECT: / /9/V 0 EXAR£SS LOCATION: 5/ ,G' KRAZAN PROJECT MANAGER: CV-FIELD ❑ SHOP WELDING ❑ M.T. ❑ P.T. ci-1� /.T. item(s) inspected: Csi le 4SZ 0e/e /icArA REPORT NO.: 4 / U l CONTRACTOR: d / , ei 2 � d 4- 7 C PERMITNO:$ b INSPECTOR. L .r N4r4 JURISDICTION: 1171/e4-2/ /4 A.//' WEATHER: ' /S4eurif/ 400 J' /faA / /J' 'c rfo Z&e Zane a"oa_ 3.3. / ewe eRs v rf T / 4 #C' /a'mre iV i97'c W - eve Nc/Et ‘9,e / elon,AIZ Ie' wr/pf (04rf'et/et) ,40t/ y c7tJ IA,T ©,e Xe•V t/ fps t r'7 1 .'J7 1 //VI-Cr /ON tom/ elp& ,Eisy/ 9Q //vi,, ,, 4I 4/f) i- Position: FU L VERITCAL HORIZONTAL OVERHEAD ❑ Filler Metal: .Process: SMAW FCAW GMAW SAW ❑ Other: i$ Type: FILLET C.P. P.P. PLUG ia. Other: f $f s dt/ .Weld Size 3 1/4" 5/16" 3/8" ❑ Other .Codes: OS— AISC TITLE 21 TITLE 24 UBC ASME To the best of my knowledge, the above WAS / WAS NOT performed in accordance with the approved plans, specifications, and regulatory requiremei Superintendent/Representative: Tec ian: Serving the We tern United States TEMP: 76 s' This field report indicates our inspector's observation and testing results based on the site condition and contractor's activities. This information is subject to review prior to final submit By signing this report, our inspector does not accept responsibility for validity of results. Some information on this report has been provided by others on site. Revision I Effective Date: 11/15. The information provided in this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. xc: 05 -08 -2008 CHARLES LEA 1683 WALNUT GROVE AV ROSEMEAD CA 91770 Dear Permit Holder: Sincerely, r Marshall Pe 'i Technician Permit File No. M07 -256 City of Tukwila RE: Permit No. M07 -256 2600 SOUTHCENTER MALL TUKW Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 06/09/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 04 -04 -2008 CHARLES LEA 1683 WALNUT GROVE AV ROSEMEAD CA 91770 RE: Permit Application No. M07 -256 2600 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 11/28/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 05/26/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 05/26/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Ja m r Marshall Pe Technician xc: Permit File No. M07 -256 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 w, DEPARTMENTS. -la ion z Public Works Complete Comments: b' PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -256 DATE: 11 -28 -07 PROJECT NAME: PANDA EXPRESS SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -10 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 Q1 MG 11 6 Fire Prevention DATE: DATE: Planning Division ❑ Permit Coordinator DUE DATE: 11-29-07 Not Applicable ❑ DUE DATE: 12 -27 -07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License AIREPP*032RU Licensee Name AIRE PRO INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601771753 Ind. Ins. Account Id 95617800 Business Type CORPORATION Address 1 2921 MERIDIAN AVE E Address 2 06/11/2001 City EDGEWOOD County PIERCE State WA Zip 98371 Phone 2539427028 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/1997 Expiration Date 3/18/2010 Suspend Date Separation Date Parent Company Previous License AIREP * *040P4 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date RAEDER, SCOTT W 01/01/1980 JENNINGS, RICHARD M AGENT 01/01/1980 KENNETH, BROECK AGENT 01/01/1980 06/11/2001 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date FEDERATED MUTUAL Until https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= AIREPI *032RU 05/01/2008 Hi v Ara Nit 32 "xI6" I / I/ Ark v 14 1 • 13 ok . . —Lao 14"4) ry I , tt� H o t i I I 0 0 .O.C. Illi H � PREPARE r Ir��.ra�. ■ ■I� O A O "4 _ H I!! it .„1„„. � 2&'x20" __� , v V - -_____ ' IUD ...., p r j o I ■i� \.j li . , .. v r 8 xI6 ����.... L —_ L 0 lam' A Ea «(([U r v = SERVIGE E -2 60 w E -2 E -2 C: Ts] I O " 4' B (TYP. 5 12"(1) 0 E_1� L � n t= A 300 18"4) I2" 5 E -1 3 SGALE: 1/4" = 1' -0" 13 4 I I 1 HVAG PARTIAL OF PLAN — 7 HVAG FLOOR PLAN SCALE: 1/4" = I -0" D ( T ?P. 3) W % .�. CODE COMPL,I.Ao CL APP MED tl Of Tukwi a DINS © ? f:N LEE- i I 716 MECHANICAL <E l' MOTES: 2 3 4 5 H I ' I PROPOSED CONDENSER LOCATION FOR WIF 4 WIG. FIELD VERIFY ' I LOCATION W/ PROJECT MANAGER / LANDLORD'S REPRESENTATIVE. S I 0 I I 13 14 13 nD 'lslnNs ! e chp.npes shall be made to fhrl of work without prior approval of I Tukwila Building Division. NOTE: Revisions will require a new I and may include additional plan review fees. INSTALL GREASE EXHAUST HOODS FURNISHED BY PANDA. HOOD SHALL BE ONE GAPTIVEAIRE 5424 -N0I HOOD EXHAUSTING 4,600 GFM. SUPPORT FROM STRUCTURE ABOVE WITH UNISTRUT AND ALL THREAD ROD. MOUNT HOOD PER LOCAL GODE REQUIREMENTS. REFER TO PLAN FOR HOOD CONNECTIONS. SEE CODE COMPLIANCE DRAWINGS ON SHEET M -3.0 AND GAPTIVEAIRE HOOD DRAWINGS FOR ADDITIONAL REQUIREMENTS. 20 "xIO" GREASE EXHAUST DUCT, FROM EXHAUST HOOD COLLAR CONNECT TO 32 "xI6" MAIN GREASE EXHAUST DUCT WITH THERMAL CERAMIC FIREMASTER DUCT WRAP+ OR EQUAL. FABRICATE DUCT FROM 16 GAUGE STEEL WITH WELDED SEAM CONSTRUCTION. SEE HOOD DETAIL DRAWINGS ON SHEET M -3.O AND GAPTIVEAIRE DRAWINGS. PROVIDE A NEW PROGRAMMABLE THERMOSTAT FOR A/C UNIT AT THIS LOCATION. MOUNT THERMOSTAT AT 48" A.F.F.. SEE TEMPERATURE CONTROL DIAGRAM ON SHEET M -2.0 FOR ADDITIONAL INFORMATION. INSTALL GREASE EXHAUST FAN WITH CURB (EF -I) FURNISHED BY PANDA. COORDINATE LOCATION OF UNITWITH STRUCTURE AND THE LANDLORD'S FIELD REPRESENTATIVE. ADJUST DUCTWORK ACCORDINGLY. FIELD VERIFY WITH LANDLORD FOR ALL ROOF PENETRATIONS. INSTALL DUCT MOUNTEr' SMOKE DETECTOR AT MAIN RETURN AIR DUCT PER IMO •010 PROVIDED BY ELECTRICAL CONTRACTOR. DETECTORS SHALL BE INTERLOCKED TO CENTRAL ALARM SYSTEM SHUT DOWN A/C UNIT UPON DETECTION OF SMOKE. PROVIDE ALL CONTROL WIRING NECESSARY TO PERFORM THIS OPERATION. 3 /" CONDENSATE DRAIN DN. TO FLOOR SINK IN MIN. I% OF SLOPE. 3 4" OVERFLOW DRAIN DN. W/ 2" ELBOW. 2O "xIO" MA DUCT CONNECT TO 20 "xIO" RISER FROM SUPPLY PLENUM. q20 GFM INSTALL GREASE EXHAUST HOODS FURNISHED BY PANDA. HOOD SHALL BE ONE GAPTIVEAIRE 5424 - NDI HOOD EXHAUSTING 1,150 GFM. SUPPORT FROM 'STRUCTURE ABOVE WITH UNISTRUT AND ALL THREAD ROD. MOUNT HOOD PER LOCAL CODE REQUIREMENTS. REFER TO PLAN FOR HOOD CONNECTIONS. SEE CODE COMPLIANCE DRAWINGS ON SHEET M -3.0 AND CAPTIVEAIRE HOOD DRAWINGS FOR ADDITIONAL REQUIREMENTS. II "xIO" GREASE EXHAUST DUCT, FROM EXHAUST HOOD COLLAR CONNECT TO 32 "xI6" MAIN GREASE EXHAUST DUCT WITH THERMAL CERAMIC FIREMASTER DUCT WRAP+ OR EQUAL. FABRICATE DUCT FROM 16 GAUGE STEEL WITH WELDED SEAM CONSTRUCTION. SEE HOOD DETAIL DRAWINGS ON SHEET M -3.0 AND CAPTIVEAIRE DRAWINGS. 32 "xI6" GREASE EXHAUST DUCT WITH THERMAL CERAMIC FIREMASTER DUCT WRAP + OR EQUAL UP THRU SHAFT BY LANDLORD TO ROOF. FIELD VERIFY EXACT SHAFT LOCATION WITH LANDLORD. EXISTING 28 "x28" MA DUCT BY LANDLORD. SET TOTAL MAKE -UP AIR TO 5,100 GFM FIELD VERIFY LOCATION W/ PROJECT MANAGER / LANDLORD'S REPRESENTATIVE. THE GREASE EXHAUST OUTLET SHALL BE UPBLAST TYPE INSTALLED SUCH THAT THE OUTLET 15 EVEN WITH THE TOP OF SCREEN WALLS FOR ROOFTOP MECHANICAL AREAS PER LANDLORD'S REQUIREMENTS. FILE COPY Permit No. Plan review apps Is Ito enrolrs and ondsskms. Approval of construction documents does not authorize the violation of any adopted code or oil Receipt of approved Field copy �d MUons is : EV cam:. // / City of Tukwila BUILDING DIVISION RECENED Cr! OF 1 ° WWII A NOV 28 2007 ..;;. M• -1 © HYG GWNSULTI NG ENGINEERS, Inc. 556 N. Diamond Bar BIvd., #304 Diamond Bar, California 4I165 Te I: (M001)3 , 16 -816S• Fax: ('1Oq)3g6 -8I6q • E -mal I: HYG@HYGENGINEER.GOM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Te I ephone : 626 .18 ,1. Fac9imlle: 626.312.8288 All ideas, designs. arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm. or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 1ST 1ST SUBMIT 2ND DRAWN BY: ARCHITECT : 1683 WALNUT GROVE AVE., SURE #301 ROSEMEAD, CA 91770 TEL: 626280.9188 FAX: 626.280.9189 E- MAIL:INFOI CALARC.NET A.W. SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 M - 1 .0 MECHANICAL PLAN PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 PANDA EXPRESS WESTFIELD SOUTHCENTER Z:1Cel Arc Proled\07 Project-CAL Arc107 -1 PX camostruction tloCUmentI170705 PX [) South Center Mdl, Tukwila, WA M1-08-D1189 MEP CnhA17D705R11 YClD744 M10.dAs, 1130301 1O1234 PM, Om TD54001 xpc3 EXHAUST AN S4Ul.E UNIT SYMBOL V DESIGNATION FAN NO. v (XISTING) ABBREVIATION mv LOCATION ROOF CFM AREA SERVED KITCHEN GREASE EXHAUST HOOD *1, *2, #3 05° FAN DUTY AIR EXHAUST N/A FAN TYPE CENTRIFUGAL BELT - DRIVEN AMT3IENT ( °F) FAN ARRANGEMENT UPBLAST N/A MIN. WHEEL PIAMETER - - {d01Z1.1.�3T� 39t 414 iO G.F.M. 5,150 WA TSP. 2.00" FAN MOTOR (FLA) B.H.P. 4.18 66 A, MOGP = 15 A FAN RPM. 1038 MFR dO10W MOTOR HP. 5.00 MINIMUM ELEC. CHARACTERISTICS 460V/3PH/60HZ OUTSIDE AIR MOTOR RPM. 1725 SQ. TO RD., OBD. FOR RETURN AIR MOTOR SPECIAL FEATURES OPEN DRIP -PROOF TSP ACCESSORIES I. VENTED MOTOR CCNER 2. GLEANOUT DOOR WITH LATCHES FOR DUCT ACCESS 24" x 24" PERFORATED MANUFACTURER GAPTIVEAIRE MODEL: B124 -GARM M. 4441_135 II FAN GO ILi SCHEDULE UNIT SYMBOL V DESIGNATION • RETURN AIR v (XISTING) ABBREVIATION LOCATION ATTIC I3O1 CFM 2p00 (05A = 500 CFM) TSP ON Ka) 05° 9H11009 TOTAL (BTU/HR) N/A SENSIBLE (BTU/HR) N/A AMT3IENT ( °F) N/A COIL ENTERING N/A I HEATING OUTPUT (BTUMR) N/A - {d01Z1.1.�3T� P01^IER SUPPLY 208V/10/6014Z COMPRESSOR (RLA) WA CONDBISER MOTOR (FLA) N/A FAN MOTOR (FLA) 5.8 MIN. CIRCUIT AMPAGITY 66 A, MOGP = 15 A IRMARK BY' CARRIER MODEL FA4B060 HORIZONTAL INSTALLATION W/ AIR FILTER, THERMOSTAT, PRIMARY 4 SECONDARY DRAIN. OPER W. : 115 LB5 APPROX SEER=-- EER= S 'L.I T HEAT PUMP SGHE ULE UNIT SYMBOL V DESIGNATION • RETURN AIR 0 (EXISTING) ABBREVIATION LOCATION ROOF 2l3M019 CFM WA TSP ON W.G.) WA 9N11009 TOTAL (81U/HR) 54,500 SENSIBLE (13111MR) 41,400 AMBIENT ( °F) 45 COIL ENTERING 61 °1 HEATING OUTPUT (BTU/HR) 51500 iv0I?J/03 -€3 POWER SUPPLY . 460V/30/601-1Z FOR (RLA) 10B CONDENSER MOTOR (FLA) 0.80 EVAPORATOR MOTOR (FLA) WA MIN. CIRCUIT AMPAGITY 15.0 A, MOGP - 25 A REMARK BY CARRIER MODEL 38ORG -060 COMPLETED WITH PLATFORM. OPER WT.: 212 LBS APPROX. SE3R =11.0 E-R -9.9, HSPF 1.4 M4ANIL L V DESIGNATION • RETURN AIR SYMBOL ABBREVIATION DESCRIPTION NECK SIZE ABV ABOVE NC MAX AFF ABOVE FINISHED FLOOR ANEMOSTAT CLG CEILING 10 "X10" DN DOWN < 30 0 , 7 , vi ANEMOSTAT DUCT SECTIONS (SUPPLY, EXHAUST, RETURN, LOUVERED FACE 14 "X14" 18" x 18" SURFACE FLEXIBLE DUCT \A N _ I MVP MANUAL VOLUME DAMPER PMD-PT LOUVERED FACE OBD OPPOSED BLADE DAMPER FIT CEILING TYPE MFR MANUFACTURER D MIN MINIMUM METAL EGGCRATE 05A OUTSIDE AIR LAY -IN < 35 SQ. TO RD., OBD. FOR RETURN AIR ROUND RIGID PUGTWORK ANEMOSTAT TSP TOTAL STATIC PRESSURE -D 24" x 24" PERFORATED TURNING VANES < 30 II CONSTRUCTION NOTES CA MECHANICAL EQUIPMENT DESIGNATION v n I FFUSEs 4 C fk I LIE SCHEDULE V DESIGNATION • RETURN AIR MANUFACTURER MODEL NO TYPE NECK SIZE FACE PLATE SIZE FRAME TYPE NC MAX REMARKS A ANEMOSTAT RMD -PTE LOUVERED FACE 10 "X10" 24" x 24" PERFORATED LAY-IN < 30 SQ. TO RD., OBD. FOR SUPPLY AIR B ANEMOSTAT PMD -PT LOUVERED FACE 14 "X14" 18" x 18" SURFACE FIT CEILING TYPE. < 30 SQ. TO RD., OBD. FOR SUPPLY AIR C ANEMOSTAT PMD-PT LOUVERED FACE 8 "x8" 12" x 12" SURFACE FIT CEILING TYPE < 30 SQ. TO RD., OBD. FOR SUPPLY AIR D ANEMOSTAT GC50 METAL EGGCRATE 22 "X22" 24" x 24" PERFORATED LAY -IN < 35 SQ. TO RD., OBD. FOR RETURN AIR E ANEMOSTAT RMD-PTE LOUVERED FACE 18 "X18" 24" x 24" PERFORATED LAY -IN < 30 SQ. TO RD., OBD. FOR MAKE -UP AIR AIR SAL.ANGE SCHEOULE ITEM e SUPPLY AIR • RETURN AIR MAKE -UP AIR EXHAUST MA BY LANDLORD 0 0 +4,830 0 EF -1 0 0 0 -4,600 -1,150 SHP /FC -1 +2,000 -1,500 0 0 TOTAL +2,000 -1,500 +4,830 -5,750 TENANT SPACE PRESSURE = -420 CFM DISCONNECT 24V — 460V/34) DISCONNECT' LO WIRE PER MANUFACTURE'S REGOMENDATION MECHANICAL SPEC I F I GAT, ONS : 1. THE WORK INCLUDES installation of HVAC systems, including grease exhaust fans and make -up air unit for kitchen hoods, kitchen hoods, space heating /air conditioning systems, supply, return, exhaust, and grease exhaust ductwork, grilles, registers, diffusers, complete control system, interlock wiring on the operation of the kitchen hood, exhaust fans, and make -up air unit, duct, insulation, and related items necessary for a complete functioning system as indicated on the plans. Furnish all new materials and equipment. 2. DRAWINGS for HVAC work are diagrammatic, showing the general location, type, layout and equipment required. The Drawings shall not be scaled for exact measurements. Refer to architectural and manufacturer's standard installation drawings for equipment connections and installation requirements, as required. Furnish and install ductwork, connections, accessories, offsets, and materials necessary to facilitate the system's functioning as indicated by the design and the equipment indicated. 3. CODE COMPLIANCE All work covered by this section shall conform to the International Mechanical Code 2000 and other Authorities having jurisdiction. in case of conflict between requirement, the most restrictive one shall apply. 4. COORDINATE with the work of other Sections, equipment furnished by others, and requirements of the Owner. Provide duct rises and drops as required for field installation and trade coordination. Notify Architect of any discrepancies before starting work. Work shall be performed by experienced tradesmen and their work shall be of high standard acceptable to the Architect. 5. DUCTWORK: Duct systems shall be rigid and shall be constructed, installed, sealed and insulated as provided in the Uniform Mechanical Code. Sheet metal shall be in accordance with ASHRAE and SMACNA standards. Sheet metal shall be galvanized sheet metal of lock- forming quality, ASTM A -525. Unless otherwise noted, duct dimensions on drawings are net inside clear dimensions on lined ducts, or sheet metal dimensions on unlined ducts. All angle iron used for support shall be galvanized. Round rigid ductwork shall conform to SMACNA table 3 -2. 6. SEAL all duct seams, transverse and longitudinal, air- tight. Provide turning vanes at all elbows or offsets exceeding 30 degrees. 7. GREASE EXHAUST SYSTEM: Provide all grease exhaust ducts fabricated of welded joint construction of 16 gauge galvanized steel or 18 gauge stainless steel. Provide access doors at all elbows and offsets per code requirements. All elbows shall be long radiused. Duct shall be installed in a rated enclosure provided by the General Contractor. 8. DUCT INSULATION: Provide 1 1/2" duct liner on all rectangular supply and return air ducts. Provide 2" duct wrap on round supply and return ducts. Duct liner shall be 3 pounds per cubic foot density neoprene coated duct liner complying with NFPA 90A, having a "K" value not to exceed 0.23. Flame spread and smoked developed ratings shall not exceed 25/50. Apply to sheet metal ductwork with 100% coverage adhesive. Provide additional mechanical fasteners on ducts over 12 wide or 16" high. Mechanical fasteners shall be "Gripnail" or welded pin and speed clips spaced per SMACNA standards. 9. ACCESS DOOR: Provide hinged access panels in ductwork where shown and as required for access to dampers or equipment. Provide insulated access doors in insulated ductwork. 10. AUTOMATIC TEMPERATURE CONTROL: Provide all interlock and control wiring for the kitchen hood system, which includes EF -1, EF-2, MA -1, and the Ansul system shut down interlock to the make -up air fan. Provide the interlock wiring from the kitchen hood ansul system. Upon activation of the ansul system the make -up air fan shall be deactivated. Provide all necessary controls and wiring for a complete and operable system. • Interlock the grease exhaust fans and the make -up air unit to start simultaneously from the switch at the hood provided. 11. TEST AND ADJUST each piece of equipment and each system as required to assure proper balance and operation. Provide a certified air balance report to the Owner showing design and measured air volumes, static pressures, fan rpms, etc. Eliminate noise and vibration, and assure proper function of controls, maintenance of temperature, and operation. Obtain inspections required by local code. Guarantee the work and the installation for one year after acceptance by the owner. Furnish the Owner with two complete sets of as -built drawings indicating all installed work including all control wiring diagrams and interlock for system operation. BY MECHANI CONTRACTOR BY ELECTRICAL CONTRACTOR BY MEGHANIGAL GONTRAGTOR BY ELECTRICAL CONTRACTOR r HOOP CONTROL PANEL AT KITCHEN 2O8V /I c III ) III r TO OTHERS ,II ) NG EXTRA RELAY SPLIT HEAT PUMP WIRING DIAGRAM N.T.S. —120V/1d) 065 -DAY TIME CLOG AUTO GRANGE OVER T WITH FAN $ SYSTEM OFF SWITCH 120V- I 'P - NOTES: I. KITCHEN EXHAUST FANS SHALL BE ELECTRICALLY INTERLOCKED WITH MAKE -UP AIR UNIT et A/C UNITS. 2. FOR WIRING 17IAGRAM, SEE CAPTIVEAIRE DWG M -5.1, M -3.2 SMOKE DUCT DETECTOR ® RETRUN DUCT DUCT MOUNTED IONIZATION TYPE SMOKE DETECTOR ON AG UNIT RETURN DUCT MAINS TO SHUT DOWN UNIT IN CASE OF FIRE. SMOKE t I tGTOR SHALL E3E UL LISTED, 5FM CERTIFIED, 24 VAG, BY EDWARDS, DH 500 HOUSING WITH I55IF SENSOR E k B� Ppit te N /:Ec 1 0767 L SiO , z. erne or NOV 28p HYG CONSULT I NG ENGINEERS, Inc. 556 N. Diamond Bar Blvd., #304 Diamond Bar, California 011165 Te I: (gOa)3G6 -8168 • Fax: (0108)3 -816 • E -mal I: HYG@HYGENGI NEER.COM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.7 FOGS IM i I e: 626.31 2.8288 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: DRAWN BY: PANDA PROJECT #: M1-08-D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD, CA 91770 TEL: 626.280.9188 FAX 626.280.9189 E MNL INFO @CALARC.NET A.W. PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 M -2.0 MECHANICAL PLAN NOTES, SPEC'S & SCHEDULES ZiCat Aft Prn)ec1107 ProOec: -CAL Ard07 -1 PX concswdWn document170705 PX 5 South Canter Mail. Tukwila. WA M1. 08 MEP Only11707q 1WYGA744_M10.dwg,11128.2E07 10:1ZE4 PM. ace TDS406 1 x.pc3 TYP. ELEVATION OF EXH. HOOD & BLOWER(N.T.S.) rej r 0 i' UPBLAST DISGHARGE 2' -0" MINIMUM ABOVE ROOF SHAFT SEPARATION AS SPEGIFIED IN DIVISION 5, ARTICLE I, GHAPTER 1 (BUILDING CODE). INDI- VIDUAL SHAFT 15 REQUIRED EXCLUSIVELY FOR EACH EXHAUST SYSTEM. THIS SHAFT SHALL BE SPAGED AWAY FROM THE DUGT A MINIMUM OF 6" AND A MAXIMUM OF 12" CANOPY TYPE (FRONT VIEW) EXHAUST TERMINATION - 10' MINIMUM FROM ADJACENT BUILDING, ADJACENT PROPERTY LINE, AIR INTAKES, OR 10' ABOVE ADJOINING GRADE LEVEL M /41l T TO HO O � M1x +MU 0 OPT 4�- � C -� 10 �C' j � CEILING i 6" MIN. N.T.S. Mr/A GREASE DUGT ROOF NTILATED SHAFT GLEANOUT DOORS IN DUGTS SHALL BE SLIDING OR HINGED MIN. 12 "x12" TIGHTLY DOOR FOR GREASE DUGT GLEAN OUT CLEAN OUT DOOR DETAIL MINIMUM GLEARANGE FROM COMBUSTIBLES 18" MINIMUM GLEARANGE FROM PROTEGTED COMBUSTIBLES 3" HOOD SHALL OVERHANG COOKING SURFACE 4' - O" AT LEAST 6 IN. ON ALL OPEN SIDES. MAXIMUM COOKING SURFACE INFORMATION GUIDE(N.T.S.) INFORMATIONAL GUIDE FOR GOMMERGIAL GOOKING HOODS EE REQUIREMENTS FOR MOTORS AND FANS 'OTEGT OUTDOOR DUGTS AGAINST CORROSION OVIDE 18" BETWEEN DUGTS AND COMBUSTIBLES OR 3" MINIMUM FROM PROTEGTED COMBUSTIBLES GENERAL I. PROVIDE ADEQUATE GLEANOUT OPENINGS FOR THOROUGH GLEANING OF DUGT SYSTEM. 2. PROVIDE ADEQUATE MAKE-UP AIR FOR PROPER OPERATION. 3. PROVIDE A SEPARATE DUGT SYSTEM FOR EAGH HOOD (SEE EXCEPTION). 4. THICKNESS OF DUGTS SHALL BE: DUCT AREA U.S. GAGE STEEL UP TO 4 SO. FT. 16 GA. OVER 4 SQ. FT. 14 GA. 5. WELD OR BRAZE ALL DUGT JOINTS AND SEAMS ON THE EXTERNAL SURFACE. 6. SUPPORT THE DUGTS AS REQUIRED BY TABLE 6 E. DO NOT PENETRATE DUGT WALLS WITH SCREWS, NAILS, ETC.. 1. SECTIONS OF DUGT SHALL NOT CONTAIN GREASE POGKETS. (FOR REFERENCE ONLY) 1A I fi r it SECTION OF EXH. HOOD & DUCT(N.T.s.) GREASE HOOD SYSTEM CALCULATION I. TYPE : CANOPY TYPE I, STAINLESS STEEL 22 SAUSE, 2. GOOKINS EQUIPMENT HOOD *1 : (2) GH I NESS RANSE, (2) DEEP FRYER. HOOD #2: RIGE COOKER, COMBI OVEN. 3. SIZE: HOOD #1: 13' -4" x 4' -O" HOOD 4t2: 5' -q" x 4'--6" 4. MIN. REQ'D GAPAGITY GFM (I) U.L. LISTED HOOD @ 4,600 GFM. (I) U.L. LISTED HOOD @ 1,150 GFM. 5. PROPOSED (I) EXHAUST FAN: EF- I © 5,150 GFM 6. EXHAUST DUGT SIZE: HOOD #I: (2) 20 "xIO" HOOD #2: (I) 11"x10" MAIN: 32 "xI6" VELOCITY @ EXHAUST DUCT 2300/(20 "x10 °/144)= 1656 FPM ISOOFPM <1656 FPM < 2500FPM : I 150/(11 "x I O "/I 44) = 1505 FPM I500FPM < 1100 FPM < 2500FPM 5150/(52 "x16 "/144)= 1617 FPM I500FPM <1611 FPM < 2500FPM S. EXHAUST FAN AND MAKE -UP AIR UNIT SHALL BE ELEGTR I GALLY INTERLOCKED AS FOLLOW: EXHAUST FAN MAKE -UP AIR EF--I MA BY LANDLORD 1. EXHAUST HOOD #1: HOOD #2 MAIN: q. FOR CODE COMPLIANCE SEE DETAIL 10. FOR FILTER SIZE SEE GAPTIVE AIR DWG #3.I NO. OF FILTERS SEE CAPTIVE AIR DWG #3.I 7 U ROOF DECK r PERFORMANCE TEST FOR LISTED MEGHANIGAL HOOD IS REQUIRED PER IMG 501.11 6" MIN. 12" MAX. AIR SPACE ALL AROUND I STORY 5/8" TYPE "X" GYP. SD. ALL AROUND DUCT (FIRE RATED SHAFT PER BLDG CODE) I Molt: I:. GREASE EXHAUST DUCT INSULATION TYPE FIRE ASTER DUCTWRAP+ + SILICON SEALANT APPROVED FOR I—HOUR OR 2—HOUR STRUCTURE. 0 a ©© 0 0 004 FOR SI: I INCH =25.4 MM FIGURE I 2—HOUR FIRE — RESISTIVE PROTECTION SYSTEM FOR GREASE DUCTS UL # YYET— RI422q ASSEMBLY NUMBER : WP 1008 (I -HR) U.L. RI31q, 88NIC2147 SHAFT DETAIL(N.T.s.) x J TRACK MTL. sTUDS(TYP.) METAL STUDS 16" 0.0. 5 4," SHEETROCK BRAND GYPSUM PANELS BY UNITED STATES GYPSUM COMPANY TYPE 5 SCREWS 0 24" 0.G. CORNER BEAD FIREGODE G CORE I" SI ICETROCK BRAND GYPSUM LINER PANELS BY UNITED STATES GYPSUM COMPANY GREASE EXHAUST DUCT INSULATION TYPE FIRE MASTER FASTWRAP+ + SILICON SEALANT APPROVED FOR I—HOUR OR 2 —HOUR STRUCTURE. 0 O 1 — FOR SI; I INCH =25.4 MM ©© 0 O 0 04 .•■ a A DEC i f A tl, FIGURE I 2—HOUR FIRE— RESISTIVE PROTECTION SYSTEM FOR GREASE DUCTS ALTERNATE 1 —HOUR OR 2 —HOUR DUCT WRAP UL # 7YET— R1422q 157 2ND 5RD 4TH 5TH 6TH THE MAXIMUM TOTAL DEVELOPED LENGTH OF DUCT AND FITING MEASURED ,ALONG THE GENTERL1NE SHALL NOT EXCEED 3 TIMES THE VERTICAL DIMENSION OF THE FAN OL 45" MIN. DOUBLE JOIST AROUND OPENING (TYP. CEILING GREASE ONTAINER HOOD LESS THAN 12" FROM CEILING MUST BE FLASHED SOLID - P -0" 45" 6 " 6" MIN. --- L TYP. HOOD LIGHT W/ SHIELD INSIDE HOOD, UL APPROVED (IF INSTALLED) 20 GA. S/5 MTL. HOOD W/ REMOVABLE GREASE FILTEP H 1/4" SLOPE PER FOOT I /4" SLOPE PER FOOT re 4•111•114 TAL FLASHING SOLID( .) GREASE CONTAINER AUTO FIRE EXTINGUISHER (SEPARATE } PERMIT BY FIRE EXTINGUISHER GO) MTL. WALL FLASHING 24 GA. 5/S SHEET MTL. GOOKINS EQUIPMENT BLOWER 10' FROM ADJACENT BUILDING 10' FROM PROPERTY LINE 4 AIR IN TAKE OPENING 10' ABOVE GRADE LEVEL 16 CA. SI. DUCT 26 GA. CI. COUNTER FLASHING ROOF DECK -1 6" MIN. 12" MAX. AIR SPACE ALL AROUND 6 "MIN, 12" MAX 6" MIN, FIN. FLOOR i 24" MIN. i I STORY L WHEN HOOD IS LESS THAN Is" BELOW CEILING, EXTENDED FIRE RATED CEILING 18" BEYOND THE HOOD ON BOTH SIDE REMOVABLE COVE 16 GA. GI. DUCT WELDED STEEL ANGLE SUPPORT RAIN GAP 26 GA. GI. COUNTER FLASHING 3" MIN. 48" 2x4 STUD WALL W/ 5 /5" TYPE "X" GYP. BD. ON BOTH SIDE 3" MIN. GOOKINS EQUIPMENT MIN. 1/4" PER FOOT SLOPE BLOWER DISGH —REMOVABLE GREASE FILTER W/ HANDLES AUTO FIRE EXTINGUISHER (SEPARATE PERMIT BY FIRE EXTINGUISHER GO) BLOWER SUPPORT 4x4 RED WOOD BOLT/NAIL TO ROOF FRAMING CEILING MTL. HOOD 20 GA. S/S MTL. WALL FLASHING 24 GA. S/S SHEET MTL. 6" TYP. ® ALL OPEN SIDES FIN. FLOOR FLOOR/ROOF STRUCTURE MIN 2 "X4" 1/2" HANGER ROD TO STRUCTURE, MAX. SPACE I2FT PROVIDE MACHINE BOLT NUT *HASHER // (4 2X4 STUD WALL W/ 5/5" TYP "X" GYP. BD. ON BOTH SIDE 3/8 "X3" LAG SGREW TO STUD - L 4X4 X 1/4 X 6" 0 45" O.G. EXHAUST HOOD TACK WELD 3" MIN. AIR SPACE DETAIL (N.T.$) DETAIL (N.T.S) 2- #12X1 -3/4" WOOD SCREWS 2 "X2 "XI /4 "X2" CLIP ANGLE BY HOOD SUPPLIER /:ob 4Pp Via® 1-IY0 GONSULTI NG ENG I NEERS, Inc. 556 N. Diamond Bar Blvd., *304 Diamond Bar, California g1 TeI :( -8165. Fax:( -SI6q• E- malI :HYG@HYGENGINEER.COM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.1gci.gSa8 FOC S lm l I e: 626.312.5255 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm. or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 1ST SUBMIT DRAWN BY: A.W. 11 -09 -07 PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD, CA 91770 TEL: 626280.9188 FAX: 626280.9189 E-MAIL. I N FO @ CALARC.N ET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 M -3.0 MECHANICAL DETAILS / KITCHEN HOOD DETAILS Z1Cal Are Projeci107 Project-CAL Arc1137 -1 PX eancetrudlon document1170705 PX South Center Mall, Tukwila, WA M1-08-1)1W9 MEP Only\170705R1 'NYC \0744_M10.Mg,11/M20071013:13 PM, qca 117S4 1 xpc3 LEGEND I 1.... :. .: 74::. • ... .4 •�- - • .• . • ' J 1 FILAMENT TAPE h" EC;EI'VE® 3 BANDING ,�, , „� n 12" NOV t!r 2 3—INCH PERIMETER OVERLAP N 2557 i 12" MAX. 6' EXHAUST MAX � 6' DUCT I MIN. MIN TYP. ELEVATION OF EXH. HOOD & BLOWER(N.T.S.) rej r 0 i' UPBLAST DISGHARGE 2' -0" MINIMUM ABOVE ROOF SHAFT SEPARATION AS SPEGIFIED IN DIVISION 5, ARTICLE I, GHAPTER 1 (BUILDING CODE). INDI- VIDUAL SHAFT 15 REQUIRED EXCLUSIVELY FOR EACH EXHAUST SYSTEM. THIS SHAFT SHALL BE SPAGED AWAY FROM THE DUGT A MINIMUM OF 6" AND A MAXIMUM OF 12" CANOPY TYPE (FRONT VIEW) EXHAUST TERMINATION - 10' MINIMUM FROM ADJACENT BUILDING, ADJACENT PROPERTY LINE, AIR INTAKES, OR 10' ABOVE ADJOINING GRADE LEVEL M /41l T TO HO O � M1x +MU 0 OPT 4�- � C -� 10 �C' j � CEILING i 6" MIN. N.T.S. Mr/A GREASE DUGT ROOF NTILATED SHAFT GLEANOUT DOORS IN DUGTS SHALL BE SLIDING OR HINGED MIN. 12 "x12" TIGHTLY DOOR FOR GREASE DUGT GLEAN OUT CLEAN OUT DOOR DETAIL MINIMUM GLEARANGE FROM COMBUSTIBLES 18" MINIMUM GLEARANGE FROM PROTEGTED COMBUSTIBLES 3" HOOD SHALL OVERHANG COOKING SURFACE 4' - O" AT LEAST 6 IN. ON ALL OPEN SIDES. MAXIMUM COOKING SURFACE INFORMATION GUIDE(N.T.S.) INFORMATIONAL GUIDE FOR GOMMERGIAL GOOKING HOODS EE REQUIREMENTS FOR MOTORS AND FANS 'OTEGT OUTDOOR DUGTS AGAINST CORROSION OVIDE 18" BETWEEN DUGTS AND COMBUSTIBLES OR 3" MINIMUM FROM PROTEGTED COMBUSTIBLES GENERAL I. PROVIDE ADEQUATE GLEANOUT OPENINGS FOR THOROUGH GLEANING OF DUGT SYSTEM. 2. PROVIDE ADEQUATE MAKE-UP AIR FOR PROPER OPERATION. 3. PROVIDE A SEPARATE DUGT SYSTEM FOR EAGH HOOD (SEE EXCEPTION). 4. THICKNESS OF DUGTS SHALL BE: DUCT AREA U.S. GAGE STEEL UP TO 4 SO. FT. 16 GA. OVER 4 SQ. FT. 14 GA. 5. WELD OR BRAZE ALL DUGT JOINTS AND SEAMS ON THE EXTERNAL SURFACE. 6. SUPPORT THE DUGTS AS REQUIRED BY TABLE 6 E. DO NOT PENETRATE DUGT WALLS WITH SCREWS, NAILS, ETC.. 1. SECTIONS OF DUGT SHALL NOT CONTAIN GREASE POGKETS. (FOR REFERENCE ONLY) 1A I fi r it SECTION OF EXH. HOOD & DUCT(N.T.s.) GREASE HOOD SYSTEM CALCULATION I. TYPE : CANOPY TYPE I, STAINLESS STEEL 22 SAUSE, 2. GOOKINS EQUIPMENT HOOD *1 : (2) GH I NESS RANSE, (2) DEEP FRYER. HOOD #2: RIGE COOKER, COMBI OVEN. 3. SIZE: HOOD #1: 13' -4" x 4' -O" HOOD 4t2: 5' -q" x 4'--6" 4. MIN. REQ'D GAPAGITY GFM (I) U.L. LISTED HOOD @ 4,600 GFM. (I) U.L. LISTED HOOD @ 1,150 GFM. 5. PROPOSED (I) EXHAUST FAN: EF- I © 5,150 GFM 6. EXHAUST DUGT SIZE: HOOD #I: (2) 20 "xIO" HOOD #2: (I) 11"x10" MAIN: 32 "xI6" VELOCITY @ EXHAUST DUCT 2300/(20 "x10 °/144)= 1656 FPM ISOOFPM <1656 FPM < 2500FPM : I 150/(11 "x I O "/I 44) = 1505 FPM I500FPM < 1100 FPM < 2500FPM 5150/(52 "x16 "/144)= 1617 FPM I500FPM <1611 FPM < 2500FPM S. EXHAUST FAN AND MAKE -UP AIR UNIT SHALL BE ELEGTR I GALLY INTERLOCKED AS FOLLOW: EXHAUST FAN MAKE -UP AIR EF--I MA BY LANDLORD 1. EXHAUST HOOD #1: HOOD #2 MAIN: q. FOR CODE COMPLIANCE SEE DETAIL 10. FOR FILTER SIZE SEE GAPTIVE AIR DWG #3.I NO. OF FILTERS SEE CAPTIVE AIR DWG #3.I 7 U ROOF DECK r PERFORMANCE TEST FOR LISTED MEGHANIGAL HOOD IS REQUIRED PER IMG 501.11 6" MIN. 12" MAX. AIR SPACE ALL AROUND I STORY 5/8" TYPE "X" GYP. SD. ALL AROUND DUCT (FIRE RATED SHAFT PER BLDG CODE) I Molt: I:. GREASE EXHAUST DUCT INSULATION TYPE FIRE ASTER DUCTWRAP+ + SILICON SEALANT APPROVED FOR I—HOUR OR 2—HOUR STRUCTURE. 0 a ©© 0 0 004 FOR SI: I INCH =25.4 MM FIGURE I 2—HOUR FIRE — RESISTIVE PROTECTION SYSTEM FOR GREASE DUCTS UL # YYET— RI422q ASSEMBLY NUMBER : WP 1008 (I -HR) U.L. RI31q, 88NIC2147 SHAFT DETAIL(N.T.s.) x J TRACK MTL. sTUDS(TYP.) METAL STUDS 16" 0.0. 5 4," SHEETROCK BRAND GYPSUM PANELS BY UNITED STATES GYPSUM COMPANY TYPE 5 SCREWS 0 24" 0.G. CORNER BEAD FIREGODE G CORE I" SI ICETROCK BRAND GYPSUM LINER PANELS BY UNITED STATES GYPSUM COMPANY GREASE EXHAUST DUCT INSULATION TYPE FIRE MASTER FASTWRAP+ + SILICON SEALANT APPROVED FOR I—HOUR OR 2 —HOUR STRUCTURE. 0 O 1 — FOR SI; I INCH =25.4 MM ©© 0 O 0 04 .•■ a A DEC i f A tl, FIGURE I 2—HOUR FIRE— RESISTIVE PROTECTION SYSTEM FOR GREASE DUCTS ALTERNATE 1 —HOUR OR 2 —HOUR DUCT WRAP UL # 7YET— R1422q 157 2ND 5RD 4TH 5TH 6TH THE MAXIMUM TOTAL DEVELOPED LENGTH OF DUCT AND FITING MEASURED ,ALONG THE GENTERL1NE SHALL NOT EXCEED 3 TIMES THE VERTICAL DIMENSION OF THE FAN OL 45" MIN. DOUBLE JOIST AROUND OPENING (TYP. CEILING GREASE ONTAINER HOOD LESS THAN 12" FROM CEILING MUST BE FLASHED SOLID - P -0" 45" 6 " 6" MIN. --- L TYP. HOOD LIGHT W/ SHIELD INSIDE HOOD, UL APPROVED (IF INSTALLED) 20 GA. S/5 MTL. HOOD W/ REMOVABLE GREASE FILTEP H 1/4" SLOPE PER FOOT I /4" SLOPE PER FOOT re 4•111•114 TAL FLASHING SOLID( .) GREASE CONTAINER AUTO FIRE EXTINGUISHER (SEPARATE } PERMIT BY FIRE EXTINGUISHER GO) MTL. WALL FLASHING 24 GA. 5/S SHEET MTL. GOOKINS EQUIPMENT BLOWER 10' FROM ADJACENT BUILDING 10' FROM PROPERTY LINE 4 AIR IN TAKE OPENING 10' ABOVE GRADE LEVEL 16 CA. SI. DUCT 26 GA. CI. COUNTER FLASHING ROOF DECK -1 6" MIN. 12" MAX. AIR SPACE ALL AROUND 6 "MIN, 12" MAX 6" MIN, FIN. FLOOR i 24" MIN. i I STORY L WHEN HOOD IS LESS THAN Is" BELOW CEILING, EXTENDED FIRE RATED CEILING 18" BEYOND THE HOOD ON BOTH SIDE REMOVABLE COVE 16 GA. GI. DUCT WELDED STEEL ANGLE SUPPORT RAIN GAP 26 GA. GI. COUNTER FLASHING 3" MIN. 48" 2x4 STUD WALL W/ 5 /5" TYPE "X" GYP. BD. ON BOTH SIDE 3" MIN. GOOKINS EQUIPMENT MIN. 1/4" PER FOOT SLOPE BLOWER DISGH —REMOVABLE GREASE FILTER W/ HANDLES AUTO FIRE EXTINGUISHER (SEPARATE PERMIT BY FIRE EXTINGUISHER GO) BLOWER SUPPORT 4x4 RED WOOD BOLT/NAIL TO ROOF FRAMING CEILING MTL. HOOD 20 GA. S/S MTL. WALL FLASHING 24 GA. S/S SHEET MTL. 6" TYP. ® ALL OPEN SIDES FIN. FLOOR FLOOR/ROOF STRUCTURE MIN 2 "X4" 1/2" HANGER ROD TO STRUCTURE, MAX. SPACE I2FT PROVIDE MACHINE BOLT NUT *HASHER // (4 2X4 STUD WALL W/ 5/5" TYP "X" GYP. BD. ON BOTH SIDE 3/8 "X3" LAG SGREW TO STUD - L 4X4 X 1/4 X 6" 0 45" O.G. EXHAUST HOOD TACK WELD 3" MIN. AIR SPACE DETAIL (N.T.$) DETAIL (N.T.S) 2- #12X1 -3/4" WOOD SCREWS 2 "X2 "XI /4 "X2" CLIP ANGLE BY HOOD SUPPLIER /:ob 4Pp Via® 1-IY0 GONSULTI NG ENG I NEERS, Inc. 556 N. Diamond Bar Blvd., *304 Diamond Bar, California g1 TeI :( -8165. Fax:( -SI6q• E- malI :HYG@HYGENGINEER.COM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.1gci.gSa8 FOC S lm l I e: 626.312.5255 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm. or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 1ST SUBMIT DRAWN BY: A.W. 11 -09 -07 PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD, CA 91770 TEL: 626280.9188 FAX: 626280.9189 E-MAIL. I N FO @ CALARC.N ET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 M -3.0 MECHANICAL DETAILS / KITCHEN HOOD DETAILS Z1Cal Are Projeci107 Project-CAL Arc1137 -1 PX eancetrudlon document1170705 PX South Center Mall, Tukwila, WA M1-08-1)1W9 MEP Only\170705R1 'NYC \0744_M10.Mg,11/M20071013:13 PM, qca 117S4 1 xpc3 LEGEND I ONE LAYERS FIRE MASTER FASTWRAP+ 2 FILAMENT TAPE h" EC;EI'VE® 3 BANDING ,�, , „� n 4 NOV t!r 2 3—INCH PERIMETER OVERLAP N 2557 5 5—INCH LONGITUDINAL OVERLAP §yW' f` LL : . 6 GREASE DUCT TYP. ELEVATION OF EXH. HOOD & BLOWER(N.T.S.) rej r 0 i' UPBLAST DISGHARGE 2' -0" MINIMUM ABOVE ROOF SHAFT SEPARATION AS SPEGIFIED IN DIVISION 5, ARTICLE I, GHAPTER 1 (BUILDING CODE). INDI- VIDUAL SHAFT 15 REQUIRED EXCLUSIVELY FOR EACH EXHAUST SYSTEM. THIS SHAFT SHALL BE SPAGED AWAY FROM THE DUGT A MINIMUM OF 6" AND A MAXIMUM OF 12" CANOPY TYPE (FRONT VIEW) EXHAUST TERMINATION - 10' MINIMUM FROM ADJACENT BUILDING, ADJACENT PROPERTY LINE, AIR INTAKES, OR 10' ABOVE ADJOINING GRADE LEVEL M /41l T TO HO O � M1x +MU 0 OPT 4�- � C -� 10 �C' j � CEILING i 6" MIN. N.T.S. Mr/A GREASE DUGT ROOF NTILATED SHAFT GLEANOUT DOORS IN DUGTS SHALL BE SLIDING OR HINGED MIN. 12 "x12" TIGHTLY DOOR FOR GREASE DUGT GLEAN OUT CLEAN OUT DOOR DETAIL MINIMUM GLEARANGE FROM COMBUSTIBLES 18" MINIMUM GLEARANGE FROM PROTEGTED COMBUSTIBLES 3" HOOD SHALL OVERHANG COOKING SURFACE 4' - O" AT LEAST 6 IN. ON ALL OPEN SIDES. MAXIMUM COOKING SURFACE INFORMATION GUIDE(N.T.S.) INFORMATIONAL GUIDE FOR GOMMERGIAL GOOKING HOODS EE REQUIREMENTS FOR MOTORS AND FANS 'OTEGT OUTDOOR DUGTS AGAINST CORROSION OVIDE 18" BETWEEN DUGTS AND COMBUSTIBLES OR 3" MINIMUM FROM PROTEGTED COMBUSTIBLES GENERAL I. PROVIDE ADEQUATE GLEANOUT OPENINGS FOR THOROUGH GLEANING OF DUGT SYSTEM. 2. PROVIDE ADEQUATE MAKE-UP AIR FOR PROPER OPERATION. 3. PROVIDE A SEPARATE DUGT SYSTEM FOR EAGH HOOD (SEE EXCEPTION). 4. THICKNESS OF DUGTS SHALL BE: DUCT AREA U.S. GAGE STEEL UP TO 4 SO. FT. 16 GA. OVER 4 SQ. FT. 14 GA. 5. WELD OR BRAZE ALL DUGT JOINTS AND SEAMS ON THE EXTERNAL SURFACE. 6. SUPPORT THE DUGTS AS REQUIRED BY TABLE 6 E. DO NOT PENETRATE DUGT WALLS WITH SCREWS, NAILS, ETC.. 1. SECTIONS OF DUGT SHALL NOT CONTAIN GREASE POGKETS. (FOR REFERENCE ONLY) 1A I fi r it SECTION OF EXH. HOOD & DUCT(N.T.s.) GREASE HOOD SYSTEM CALCULATION I. TYPE : CANOPY TYPE I, STAINLESS STEEL 22 SAUSE, 2. GOOKINS EQUIPMENT HOOD *1 : (2) GH I NESS RANSE, (2) DEEP FRYER. HOOD #2: RIGE COOKER, COMBI OVEN. 3. SIZE: HOOD #1: 13' -4" x 4' -O" HOOD 4t2: 5' -q" x 4'--6" 4. MIN. REQ'D GAPAGITY GFM (I) U.L. LISTED HOOD @ 4,600 GFM. (I) U.L. LISTED HOOD @ 1,150 GFM. 5. PROPOSED (I) EXHAUST FAN: EF- I © 5,150 GFM 6. EXHAUST DUGT SIZE: HOOD #I: (2) 20 "xIO" HOOD #2: (I) 11"x10" MAIN: 32 "xI6" VELOCITY @ EXHAUST DUCT 2300/(20 "x10 °/144)= 1656 FPM ISOOFPM <1656 FPM < 2500FPM : I 150/(11 "x I O "/I 44) = 1505 FPM I500FPM < 1100 FPM < 2500FPM 5150/(52 "x16 "/144)= 1617 FPM I500FPM <1611 FPM < 2500FPM S. EXHAUST FAN AND MAKE -UP AIR UNIT SHALL BE ELEGTR I GALLY INTERLOCKED AS FOLLOW: EXHAUST FAN MAKE -UP AIR EF--I MA BY LANDLORD 1. EXHAUST HOOD #1: HOOD #2 MAIN: q. FOR CODE COMPLIANCE SEE DETAIL 10. FOR FILTER SIZE SEE GAPTIVE AIR DWG #3.I NO. OF FILTERS SEE CAPTIVE AIR DWG #3.I 7 U ROOF DECK r PERFORMANCE TEST FOR LISTED MEGHANIGAL HOOD IS REQUIRED PER IMG 501.11 6" MIN. 12" MAX. AIR SPACE ALL AROUND I STORY 5/8" TYPE "X" GYP. SD. ALL AROUND DUCT (FIRE RATED SHAFT PER BLDG CODE) I Molt: I:. GREASE EXHAUST DUCT INSULATION TYPE FIRE ASTER DUCTWRAP+ + SILICON SEALANT APPROVED FOR I—HOUR OR 2—HOUR STRUCTURE. 0 a ©© 0 0 004 FOR SI: I INCH =25.4 MM FIGURE I 2—HOUR FIRE — RESISTIVE PROTECTION SYSTEM FOR GREASE DUCTS UL # YYET— RI422q ASSEMBLY NUMBER : WP 1008 (I -HR) U.L. RI31q, 88NIC2147 SHAFT DETAIL(N.T.s.) x J TRACK MTL. sTUDS(TYP.) METAL STUDS 16" 0.0. 5 4," SHEETROCK BRAND GYPSUM PANELS BY UNITED STATES GYPSUM COMPANY TYPE 5 SCREWS 0 24" 0.G. CORNER BEAD FIREGODE G CORE I" SI ICETROCK BRAND GYPSUM LINER PANELS BY UNITED STATES GYPSUM COMPANY GREASE EXHAUST DUCT INSULATION TYPE FIRE MASTER FASTWRAP+ + SILICON SEALANT APPROVED FOR I—HOUR OR 2 —HOUR STRUCTURE. 0 O 1 — FOR SI; I INCH =25.4 MM ©© 0 O 0 04 .•■ a A DEC i f A tl, FIGURE I 2—HOUR FIRE— RESISTIVE PROTECTION SYSTEM FOR GREASE DUCTS ALTERNATE 1 —HOUR OR 2 —HOUR DUCT WRAP UL # 7YET— R1422q 157 2ND 5RD 4TH 5TH 6TH THE MAXIMUM TOTAL DEVELOPED LENGTH OF DUCT AND FITING MEASURED ,ALONG THE GENTERL1NE SHALL NOT EXCEED 3 TIMES THE VERTICAL DIMENSION OF THE FAN OL 45" MIN. DOUBLE JOIST AROUND OPENING (TYP. CEILING GREASE ONTAINER HOOD LESS THAN 12" FROM CEILING MUST BE FLASHED SOLID - P -0" 45" 6 " 6" MIN. --- L TYP. HOOD LIGHT W/ SHIELD INSIDE HOOD, UL APPROVED (IF INSTALLED) 20 GA. S/5 MTL. HOOD W/ REMOVABLE GREASE FILTEP H 1/4" SLOPE PER FOOT I /4" SLOPE PER FOOT re 4•111•114 TAL FLASHING SOLID( .) GREASE CONTAINER AUTO FIRE EXTINGUISHER (SEPARATE } PERMIT BY FIRE EXTINGUISHER GO) MTL. WALL FLASHING 24 GA. 5/S SHEET MTL. GOOKINS EQUIPMENT BLOWER 10' FROM ADJACENT BUILDING 10' FROM PROPERTY LINE 4 AIR IN TAKE OPENING 10' ABOVE GRADE LEVEL 16 CA. SI. DUCT 26 GA. CI. COUNTER FLASHING ROOF DECK -1 6" MIN. 12" MAX. AIR SPACE ALL AROUND 6 "MIN, 12" MAX 6" MIN, FIN. FLOOR i 24" MIN. i I STORY L WHEN HOOD IS LESS THAN Is" BELOW CEILING, EXTENDED FIRE RATED CEILING 18" BEYOND THE HOOD ON BOTH SIDE REMOVABLE COVE 16 GA. GI. DUCT WELDED STEEL ANGLE SUPPORT RAIN GAP 26 GA. GI. COUNTER FLASHING 3" MIN. 48" 2x4 STUD WALL W/ 5 /5" TYPE "X" GYP. BD. ON BOTH SIDE 3" MIN. GOOKINS EQUIPMENT MIN. 1/4" PER FOOT SLOPE BLOWER DISGH —REMOVABLE GREASE FILTER W/ HANDLES AUTO FIRE EXTINGUISHER (SEPARATE PERMIT BY FIRE EXTINGUISHER GO) BLOWER SUPPORT 4x4 RED WOOD BOLT/NAIL TO ROOF FRAMING CEILING MTL. HOOD 20 GA. S/S MTL. WALL FLASHING 24 GA. S/S SHEET MTL. 6" TYP. ® ALL OPEN SIDES FIN. FLOOR FLOOR/ROOF STRUCTURE MIN 2 "X4" 1/2" HANGER ROD TO STRUCTURE, MAX. SPACE I2FT PROVIDE MACHINE BOLT NUT *HASHER // (4 2X4 STUD WALL W/ 5/5" TYP "X" GYP. BD. ON BOTH SIDE 3/8 "X3" LAG SGREW TO STUD - L 4X4 X 1/4 X 6" 0 45" O.G. EXHAUST HOOD TACK WELD 3" MIN. AIR SPACE DETAIL (N.T.$) DETAIL (N.T.S) 2- #12X1 -3/4" WOOD SCREWS 2 "X2 "XI /4 "X2" CLIP ANGLE BY HOOD SUPPLIER /:ob 4Pp Via® 1-IY0 GONSULTI NG ENG I NEERS, Inc. 556 N. Diamond Bar Blvd., *304 Diamond Bar, California g1 TeI :( -8165. Fax:( -SI6q• E- malI :HYG@HYGENGINEER.COM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.1gci.gSa8 FOC S lm l I e: 626.312.5255 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm. or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 1ST SUBMIT DRAWN BY: A.W. 11 -09 -07 PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD, CA 91770 TEL: 626280.9188 FAX: 626280.9189 E-MAIL. I N FO @ CALARC.N ET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 M -3.0 MECHANICAL DETAILS / KITCHEN HOOD DETAILS Z1Cal Are Projeci107 Project-CAL Arc1137 -1 PX eancetrudlon document1170705 PX South Center Mall, Tukwila, WA M1-08-1)1W9 MEP Only\170705R1 'NYC \0744_M10.Mg,11/M20071013:13 PM, qca 117S4 1 xpc3 LEGEND I TWO LAYERS FIRE MASTER DUCTIIRAP + 2 FILAMENT TAPE 3 BANDING 4 3—INCH PERIMETER OVERLAP 5 3 —INCH LONGITUDINAL OVERLAP 6 GREASE DUCT TYP. ELEVATION OF EXH. HOOD & BLOWER(N.T.S.) rej r 0 i' UPBLAST DISGHARGE 2' -0" MINIMUM ABOVE ROOF SHAFT SEPARATION AS SPEGIFIED IN DIVISION 5, ARTICLE I, GHAPTER 1 (BUILDING CODE). INDI- VIDUAL SHAFT 15 REQUIRED EXCLUSIVELY FOR EACH EXHAUST SYSTEM. THIS SHAFT SHALL BE SPAGED AWAY FROM THE DUGT A MINIMUM OF 6" AND A MAXIMUM OF 12" CANOPY TYPE (FRONT VIEW) EXHAUST TERMINATION - 10' MINIMUM FROM ADJACENT BUILDING, ADJACENT PROPERTY LINE, AIR INTAKES, OR 10' ABOVE ADJOINING GRADE LEVEL M /41l T TO HO O � M1x +MU 0 OPT 4�- � C -� 10 �C' j � CEILING i 6" MIN. N.T.S. Mr/A GREASE DUGT ROOF NTILATED SHAFT GLEANOUT DOORS IN DUGTS SHALL BE SLIDING OR HINGED MIN. 12 "x12" TIGHTLY DOOR FOR GREASE DUGT GLEAN OUT CLEAN OUT DOOR DETAIL MINIMUM GLEARANGE FROM COMBUSTIBLES 18" MINIMUM GLEARANGE FROM PROTEGTED COMBUSTIBLES 3" HOOD SHALL OVERHANG COOKING SURFACE 4' - O" AT LEAST 6 IN. ON ALL OPEN SIDES. MAXIMUM COOKING SURFACE INFORMATION GUIDE(N.T.S.) INFORMATIONAL GUIDE FOR GOMMERGIAL GOOKING HOODS EE REQUIREMENTS FOR MOTORS AND FANS 'OTEGT OUTDOOR DUGTS AGAINST CORROSION OVIDE 18" BETWEEN DUGTS AND COMBUSTIBLES OR 3" MINIMUM FROM PROTEGTED COMBUSTIBLES GENERAL I. PROVIDE ADEQUATE GLEANOUT OPENINGS FOR THOROUGH GLEANING OF DUGT SYSTEM. 2. PROVIDE ADEQUATE MAKE-UP AIR FOR PROPER OPERATION. 3. PROVIDE A SEPARATE DUGT SYSTEM FOR EAGH HOOD (SEE EXCEPTION). 4. THICKNESS OF DUGTS SHALL BE: DUCT AREA U.S. GAGE STEEL UP TO 4 SO. FT. 16 GA. OVER 4 SQ. FT. 14 GA. 5. WELD OR BRAZE ALL DUGT JOINTS AND SEAMS ON THE EXTERNAL SURFACE. 6. SUPPORT THE DUGTS AS REQUIRED BY TABLE 6 E. DO NOT PENETRATE DUGT WALLS WITH SCREWS, NAILS, ETC.. 1. SECTIONS OF DUGT SHALL NOT CONTAIN GREASE POGKETS. (FOR REFERENCE ONLY) 1A I fi r it SECTION OF EXH. HOOD & DUCT(N.T.s.) GREASE HOOD SYSTEM CALCULATION I. TYPE : CANOPY TYPE I, STAINLESS STEEL 22 SAUSE, 2. GOOKINS EQUIPMENT HOOD *1 : (2) GH I NESS RANSE, (2) DEEP FRYER. HOOD #2: RIGE COOKER, COMBI OVEN. 3. SIZE: HOOD #1: 13' -4" x 4' -O" HOOD 4t2: 5' -q" x 4'--6" 4. MIN. REQ'D GAPAGITY GFM (I) U.L. LISTED HOOD @ 4,600 GFM. (I) U.L. LISTED HOOD @ 1,150 GFM. 5. PROPOSED (I) EXHAUST FAN: EF- I © 5,150 GFM 6. EXHAUST DUGT SIZE: HOOD #I: (2) 20 "xIO" HOOD #2: (I) 11"x10" MAIN: 32 "xI6" VELOCITY @ EXHAUST DUCT 2300/(20 "x10 °/144)= 1656 FPM ISOOFPM <1656 FPM < 2500FPM : I 150/(11 "x I O "/I 44) = 1505 FPM I500FPM < 1100 FPM < 2500FPM 5150/(52 "x16 "/144)= 1617 FPM I500FPM <1611 FPM < 2500FPM S. EXHAUST FAN AND MAKE -UP AIR UNIT SHALL BE ELEGTR I GALLY INTERLOCKED AS FOLLOW: EXHAUST FAN MAKE -UP AIR EF--I MA BY LANDLORD 1. EXHAUST HOOD #1: HOOD #2 MAIN: q. FOR CODE COMPLIANCE SEE DETAIL 10. FOR FILTER SIZE SEE GAPTIVE AIR DWG #3.I NO. OF FILTERS SEE CAPTIVE AIR DWG #3.I 7 U ROOF DECK r PERFORMANCE TEST FOR LISTED MEGHANIGAL HOOD IS REQUIRED PER IMG 501.11 6" MIN. 12" MAX. AIR SPACE ALL AROUND I STORY 5/8" TYPE "X" GYP. SD. ALL AROUND DUCT (FIRE RATED SHAFT PER BLDG CODE) I Molt: I:. GREASE EXHAUST DUCT INSULATION TYPE FIRE ASTER DUCTWRAP+ + SILICON SEALANT APPROVED FOR I—HOUR OR 2—HOUR STRUCTURE. 0 a ©© 0 0 004 FOR SI: I INCH =25.4 MM FIGURE I 2—HOUR FIRE — RESISTIVE PROTECTION SYSTEM FOR GREASE DUCTS UL # YYET— RI422q ASSEMBLY NUMBER : WP 1008 (I -HR) U.L. RI31q, 88NIC2147 SHAFT DETAIL(N.T.s.) x J TRACK MTL. sTUDS(TYP.) METAL STUDS 16" 0.0. 5 4," SHEETROCK BRAND GYPSUM PANELS BY UNITED STATES GYPSUM COMPANY TYPE 5 SCREWS 0 24" 0.G. CORNER BEAD FIREGODE G CORE I" SI ICETROCK BRAND GYPSUM LINER PANELS BY UNITED STATES GYPSUM COMPANY GREASE EXHAUST DUCT INSULATION TYPE FIRE MASTER FASTWRAP+ + SILICON SEALANT APPROVED FOR I—HOUR OR 2 —HOUR STRUCTURE. 0 O 1 — FOR SI; I INCH =25.4 MM ©© 0 O 0 04 .•■ a A DEC i f A tl, FIGURE I 2—HOUR FIRE— RESISTIVE PROTECTION SYSTEM FOR GREASE DUCTS ALTERNATE 1 —HOUR OR 2 —HOUR DUCT WRAP UL # 7YET— R1422q 157 2ND 5RD 4TH 5TH 6TH THE MAXIMUM TOTAL DEVELOPED LENGTH OF DUCT AND FITING MEASURED ,ALONG THE GENTERL1NE SHALL NOT EXCEED 3 TIMES THE VERTICAL DIMENSION OF THE FAN OL 45" MIN. DOUBLE JOIST AROUND OPENING (TYP. CEILING GREASE ONTAINER HOOD LESS THAN 12" FROM CEILING MUST BE FLASHED SOLID - P -0" 45" 6 " 6" MIN. --- L TYP. HOOD LIGHT W/ SHIELD INSIDE HOOD, UL APPROVED (IF INSTALLED) 20 GA. S/5 MTL. HOOD W/ REMOVABLE GREASE FILTEP H 1/4" SLOPE PER FOOT I /4" SLOPE PER FOOT re 4•111•114 TAL FLASHING SOLID( .) GREASE CONTAINER AUTO FIRE EXTINGUISHER (SEPARATE } PERMIT BY FIRE EXTINGUISHER GO) MTL. WALL FLASHING 24 GA. 5/S SHEET MTL. GOOKINS EQUIPMENT BLOWER 10' FROM ADJACENT BUILDING 10' FROM PROPERTY LINE 4 AIR IN TAKE OPENING 10' ABOVE GRADE LEVEL 16 CA. SI. DUCT 26 GA. CI. COUNTER FLASHING ROOF DECK -1 6" MIN. 12" MAX. AIR SPACE ALL AROUND 6 "MIN, 12" MAX 6" MIN, FIN. FLOOR i 24" MIN. i I STORY L WHEN HOOD IS LESS THAN Is" BELOW CEILING, EXTENDED FIRE RATED CEILING 18" BEYOND THE HOOD ON BOTH SIDE REMOVABLE COVE 16 GA. GI. DUCT WELDED STEEL ANGLE SUPPORT RAIN GAP 26 GA. GI. COUNTER FLASHING 3" MIN. 48" 2x4 STUD WALL W/ 5 /5" TYPE "X" GYP. BD. ON BOTH SIDE 3" MIN. GOOKINS EQUIPMENT MIN. 1/4" PER FOOT SLOPE BLOWER DISGH —REMOVABLE GREASE FILTER W/ HANDLES AUTO FIRE EXTINGUISHER (SEPARATE PERMIT BY FIRE EXTINGUISHER GO) BLOWER SUPPORT 4x4 RED WOOD BOLT/NAIL TO ROOF FRAMING CEILING MTL. HOOD 20 GA. S/S MTL. WALL FLASHING 24 GA. S/S SHEET MTL. 6" TYP. ® ALL OPEN SIDES FIN. FLOOR FLOOR/ROOF STRUCTURE MIN 2 "X4" 1/2" HANGER ROD TO STRUCTURE, MAX. SPACE I2FT PROVIDE MACHINE BOLT NUT *HASHER // (4 2X4 STUD WALL W/ 5/5" TYP "X" GYP. BD. ON BOTH SIDE 3/8 "X3" LAG SGREW TO STUD - L 4X4 X 1/4 X 6" 0 45" O.G. EXHAUST HOOD TACK WELD 3" MIN. AIR SPACE DETAIL (N.T.$) DETAIL (N.T.S) 2- #12X1 -3/4" WOOD SCREWS 2 "X2 "XI /4 "X2" CLIP ANGLE BY HOOD SUPPLIER /:ob 4Pp Via® 1-IY0 GONSULTI NG ENG I NEERS, Inc. 556 N. Diamond Bar Blvd., *304 Diamond Bar, California g1 TeI :( -8165. Fax:( -SI6q• E- malI :HYG@HYGENGINEER.COM PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.1gci.gSa8 FOC S lm l I e: 626.312.5255 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm. or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 1ST SUBMIT DRAWN BY: A.W. 11 -09 -07 PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE., SUITE #301 ROSEMEAD, CA 91770 TEL: 626280.9188 FAX: 626280.9189 E-MAIL. I N FO @ CALARC.N ET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 M -3.0 MECHANICAL DETAILS / KITCHEN HOOD DETAILS Z1Cal Are Projeci107 Project-CAL Arc1137 -1 PX eancetrudlon document1170705 PX South Center Mall, Tukwila, WA M1-08-1)1W9 MEP Only\170705R1 'NYC \0744_M10.Mg,11/M20071013:13 PM, qca 117S4 1 xpc3 . 3" FINISHED UNINSULATED STANDOFF .. ... ... 3" UNINSULATED STANDOFF i 0 I( 0 o i arm • l 1 o I I o I 1 . 7 0000" 10.i 0000" 4 PA r ZA --- Fix ---1 11.0000" Hood #5 U.L. Listed Incandescent Light C 0 lit 0 0 //i 11■41 W A &AAA W WAWA A AAA& wwww AL MAMMA W WWWW z 3" EJNINSUL 3" UNINSULATED STANDOFF cc, 2 2 [ 0 1 10 Hood #1 10.00 '23.0000" 46.0000" SUPPLY 10.0000" U.L. Listed Incandescent Light Fix 20.0000" C EXHAUST EXHAUST 47.0000" 7' 8.00" 7' 11.00" 10.0000" 34.5000" 7.0000" 5' 9.00" 6.00' PLAN VIEW - Hood #5 - 5' 9.00" LONG 51 24ND Utility Cabinet 12.0000" 8.0000" 46 0000" , t L SUPPLY 25.0000" 101 jof 101 15' 7.00" 3.0000' 1 01 Hood #2 U.L. Listed Incandescent Light Fix 1 0 1 10.0 PR WIT SU"' (SE LIG PR 10.0000" 23.0000" - 1" >7 46.0000" SUPPLY HANGING ANGLE 3" UNINSULATED STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS AN'UL R-102 WET CHEMICAL FIR SUPPRESSION SYSTEM FA • ORY PREWIRED CONDUIT 54.0000" 51.0000' 20.0000" 46.0000" 7' 8.00" 7' 8.00" T & (LIGHTED) FAN SWITCH WIRED BY CAPTIVE-AIRE SYSTEMS. 10.000 • [Li EXHAUST PLAN VIEW - Hood #1 - 7' 8.00" LONG 4824ND PLAN VIEW - Hood #2 - 7' 8.00" LONG 4824ND PLAN VIEW - Hood #3 - 7' 1 1 .00" LONG 1 66MISC-PSP PLAN VIEW - Hood #4 7' 8.00" LONG 1 66MISC-PSP 7.0000" 46.0000" h_ SUPPLY I 23.0000" EXHAUST RISER 100W VAPORPROOF INCANDESCENT LIGHT 16" U.L. CLASSIFIED BAFFLE-TYPE GREASE FILTERS LOPED GREASE DRAIN WITH REMOVABLE CUP 51" 11 EQUIPMENT BY OTHERS 10 101 8.0000" 1 01 33" MIN 48" MAX WIRED ELECTRICAL PACKAGE SECTION VIEW - MODEL 4824-ND FAN STARTERS AND PLY FAN SHUT-DOWN RELAY. with PSP Accessory ELECTRICAL DRAWINGS FOR DETAILS) • 3.0000" 48.0008' 16.0000" 2.75" IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS 24" 3" UNINSULATED STANDOFF 24" -1 78" TYP. QU PAN 23.5% OPEN STAINLESS STEEL PERFORATED PANEL RTER END EL HANGING ANGLE VOLUME ONLY DAMPER •0' AFF W VAPORPROOF NDESCENT LIGHT MODEL 5124-ND RESISTANCE VS. AIRFLOW - 2" lOrsa-Gard Baf &Type Grease Flea LO 0.6 02 00/ CM FILTER DETAIL 33" MIN 48" MAX 2C0 I1.01 250 / 127 3430/ L52 350/1-73 AIRFLOW (fpm/m/s) 24" NOM 78" TYP. 9'6" 0.175 0.025 450/ 203 C5 RESEARCH PRODUCIS (ORPORST1011 Kleen-Gard Baffle Type Filters are UL Classified Grease Extracting Filters. MEA # 168-78-M Aluminum MBA # 247-96-E Stainless 1/2" DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE 1 /2" DIA. HEAVY DUTY NUT ONE ABOVE AND ONE BELOW: HANGING ANGLE STEEL HANGING ANGLE * ROD AND NUTS TO BE SUPPUED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE-PUNCHED AT FACTORY HANGING ANGLE DETAIL HOOD STYLE CANOPY EXHAUST ONLY WITH PSP BACKSHELF EXHAUST ONLY TYPE II FRONT/BACK DIMS BY SIZE DIM FROM REAR 2.00" 2.00" 2.00" 36"X36" 5" DIM FROM FRONT (24' H) 10.50" 10.50" 14.25" 42"X42" DIM FROM FRONT (30' 11) 6.00" 6.00" 48"X48" HANGING ANGLE LOCATIONS EXHAUST CFM = LENGTH OF HOOD X CFMAIN.FT. (LOAD) SUPPLY CFM=EXHAUST CFM X PERCENTAGE REQUIRED TOTAL DUCT AREA X CFM DUCT LENGTH= FPM(*) TOTAL DUCT AREA DUCT DEPTH *CAPTIVE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST VELOCITY OF 1500-1800 FPM AND A SUPPLY VELOCITY OF 1000 FPM. CALCULATIONS UTILIZED CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH: , #3054804-001 cc #3054804-002 BUILDING CODES CAPTIVE-AIRE HOODS HAVE OPTIONAL CLEARANCE REDUCTION SYSTEMS AVAILABLE AS FOLLOWS: MATERIAL NON-COMBUSTIBLE LIMITED-COMBUSTIBLE COMBUSTIBLE CLEARANCE REDUCTION SYSTEM NONE REQUIRED 3" UN INSULATED STANDOFF 3" INSULATED STANDOFF CLEARANCE TO COMBUSTIBLES INSTALLATION 1. ALL ELECTRICAL "FIELD" CONNECTIONS AND RELATED INTERCONNECTIONS BY ELECTRICAL CONTRACTORS. 2. ALL PLUMBING "FIELD" CONNECTIONS AND RELATED INTERCONNECTIONS BY PLUMBING CONTRACTORS. 3. HANGING BRACKETS LOCATED AND WELDED AS SHOWN ON PLANS. ALL OTHER HANGER MATERIALS PROVIDED BY INSTALU NG CONTRACTORS. 4. ALL CONNECTIONS FROM CAFMVE DUCT PER MECHANICAL CONTRACTORS'S PLANS. 5. COOKING EQUIPMENT TO SHUTOFF IN EVENT OF FIRE. 6. EXHAUST FANS TO TURN ON IN EVENT OF FIRE. 7. ALL LIGHTS FIXTURE SHOWN INSTALLED BY CAPTIVE-AIRE ARE FACTORY PREWIRED. INTERCONNECTIONS BETWEEN HOODS AND TO SWITCHES BY ELECTRICAL CONTRACTORS. 8. LAMPS FOR LIGHT FIXTURES BY INSTALUNG CONTRACTORS. 9. SEISMIC RESTAINTS ARE RESPONSIBILITY OF INSTALLING CONTRACTOR. 10. INSTALLING CONTRACTORS ASSUME ALL RELATED REPONS/BILITY FOR VERIFICATION OF DIMENSIONAL DATA CONTAINED ON THESE DOCUMENTS FOR ACCURACY, INTEGRATION, AND ADMINISTRATION OF CODE REQUIREMENTS IN EFFECT PRIOR TO ANY RELEASE FOR PRODUCTION OF EQUIPMENT SHOWN. BALANCE 11. KITCHEN HOODS MUST BE BALANCED WITH KITCHEN. 12. KITCHEN SHALL BE NEGATIVE WITH RESPECT TO DINING AREA. 13. RESTAURANT SHALL BE POSMVE WITH RESPECT TO AMBIENT PRESSURE. ADDITIONAL 14. WRITTEN HOOD DIMENSIONS HAVE PRECEDENCE OVER SCALE. 15. SIGNED AND "APPROVED" COPIES OF THIS DOCUMENT MUST BE RECEIVED BY THE FACTORY PRIOR TO COMMENCEMENT OF FABRICATION. GENERAL NOTES SECTION VIEW - 'REV1E\NED FO CODE C.OMPLIANC APEMO • SEC A EXHAUST RISE 100 \-16" U.L. C BAFFLE- GREASE - Ot It04 V110 110.100,i INCA LOPED GREASE DRAIN WITH REMOVABLE CUP 51" 54" EQUIPMEN BY OTHER RECEIVED CITY OP TUKWQA NOV 28 2007 49 AEI /MEM AlIONIM= PE 1 =NM MINI00011 koodilliPS TIV/ AM, ==i =El // NUM NNW 111 AV /11/Zia = Mr111•11 NM/ AMINI■ ■11/ BMW MI=■NEWS • SOUTHERN CALIFORNIA REGIONAL OFFICE 17910 SKYPARK SUITE 210, IRVINE, CA 92614 PHONE: (949) 660-7701, (800) 967-7701 FAX: (949) 660-7702 •Visit us at www.captiveair.com PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Telephone: 626.71 Facsimile: 626312.82E58 All ideas, designs, arrangement and plans indicated or represented by this drawing are the property of Panda Express Inc. and were created for use on this specific project. None of these ideas. designs. arrangements or plans may be used by or disclosed to any person. firm, or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: 1ST 1ST, SUBMIT DRAWN BY: PANDA PROJECT #: M1-08-D1189 HYC PROJECT #: CPC0719 ARCHITECT: 1683 WALNUT GROVE AVE, SURE #301 ROSEMEAD, CA 91770 TEL: 628280.9188 FAX 628280.9189 E-MAIL: INFO@CALARC.NET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. FC-10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 M-3.1 HOOD DETAIL PLAN ZACal Arc Prolact1137 ProJect-CAL Arc107-1 PX concsfructIon documanfti 70705 PX 5 Smith Center Mull, Tukwila, WA Mt-08-011EG MEP OnlyM7070Mi10-WC5744-CAP.dwo, 111202037 10:09 PM, Cbia TDS400 tx_pc3 HOOD N0. MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD CONFIG. END TO END ROW TOTAL EXH. CFM RISERS) TOTAL SUP. CFM RISER(S) WIDTH LENG. DIA. CFM S.P. WIDTH LENG. DIA. CFM S.P. 1 4824 ND 7' 8.00" 600 Deg 2300 10" 20" 3 2300 —0.651" 0 920 YES 307 LBS. 3 20" 430 SS Where Exposed LEFT N N/A 2 20 16 4 Incandescent Light Fix 2 4824 ND 7' 8.00" 600 Deg• 2300 10" 20" YES 2300 -- -0.651 " 0 20" 3 430 SS Where Exposed RIGHT N/A 3 166 MISC —PSP 7' 11.00" 300 Deg• 0 SS Baffle with Handles 3 16" 16" 0 3 1840 NO Right Ansu R102 3.0/3.0 31011028 430 SS Where Exposed ALONE N/A 4 166 MISC —PSP 7' 8.00" 300 Deg• 0 1840 430 SS Where Exposed ALONE N/A 5 5124 ND 5' 9.00" 450 Deg, 1150 10" 11" ^ 1150 — 0.376" 0 SS Where Ed Exposed ALONE N/A FAN UNIT NO. FAN UNIT MODEL # EXHAUST FAN SUPPLY FAN MODEL TAG CFM S.P. RPM M.P. 0 VOLT FLA BLOWER HOUSING TAG CFM S.P. RPM W.P. 0 VOLT FLA 1 BI24CARM BI24CARM 460 5750 — 2.000' 1038 5.000 3 460 6.4 920 YES 307 LBS. 3 20" 20" 2 SS Baffle with Handles 2 N0. TAG PACKAGE # LOCATION SWITCHES ROOFTOP STARTERS OPTION FANS CONTROLLED LOCATION QUANTITY TYPE 0 H.P. VOLT. FLA 1 SWITCHES 31011028 Utility Cabinet Right Hood # 5 Utility Cabinet Right Hood # 5 1 Li 1 Fan LOCATION Exhaust in Fire, Relay w/ 2—DPDT Exhaust 3 5.000 460 6.4 NO. FAN ITEM 1 SIZE ^. k 1 # 1 Curb 4.000 "W x 60.000 x 10.000 "H FAN NO. - ` -� OPTION (Qty. -- Descr.) _ : y; 1 � LIGHT(S) 1 1 — Rubber Vibration Isolators for BI Utility Sets (set of 6)L �, - (Ai O —_ 9.)i III :N..- 3 LUCIA/PI� ^. k jj v ,�,! HOOD NO. � ;,� ... x. Vl.I111 x.1... FILTER(S) LIGHT(S) UTILITY CABINET(S) � FIRE SYSTEM PIPING HOOD WEIGHT TYPE QTY. HEIGHT LENGTH QTY. TYPE W GUARD LOCATION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # . QUANTITY LOCATION 1 SS Baffle with Handles 2 » 20 » 16 4 Incandescent Light Fix NO 16" I 6" 10" 20" 920 YES 307 LBS. 3 20" 20" 2 SS Baffle with Handles 2 20 16 4 Incandescent Light Fix NO BALANCE DAMPERS YES 316 LBS. 3 20" 20" 3 0 LEFT END STANDOFF (FINISHED) NO 44 LBS. 4 5 SS Baffle with Handles 3 16" 16" 0 3 Incandescent Light Fix NO Right Ansu R102 3.0/3.0 31011028 1 L 1 Fan Outside NO YES 43 LBS. 369 LBS. 1 16 ' 20" HOOD NO POS. LENGTH WIDTH HEIGHT RISER(S) WIDTH LENG. DIA. CFM S.P. 3 Front 95" 16" 6" 10" 20" 920 0.182" 10" 20" 920 0.182" 4 I Front 92" I 16" I 6" 10" 20" 920 0.182" 10" 20" 920 0.182" HOOD NO. OPTION 1 BACK STANDOFF (FLAT) 3" Wide LEFT END STANDOFF 3" Wide BALANCE DAMPERS 2 BACK STANDOFF (FLAT) 3" Wide RIGHT QUARTER END PANEL 23" Top Width, 0" Bottom Width, 23" High 430 SS BALANCE DAMPERS 5 BACK STANDOFF (FLAT) 3" Wide BALANCE DAMPERS LEFT END STANDOFF (FINISHED) 3" Wide AU BI SERIES RESTAURANT DUTY UTILITY SET D `I SHAFT DIA. FAN MODEL BI24 AU 49 13/16 HOOD INFORMATION OPTIONS D 26 T K E 19 3/8 PERFORATED SUPPLY PLENUM(S) W GENERAL & RESTAURANT DUTY UTILITY SET DIMENSIONAL DATA F 51 5/16 G 32 0 H 46 1/2 E V K 29 15/16 0 26 F FF P P 28 15/16 S 18 9/16 D — OPTIONAL SUPPORT RAILS T H 25 1/2 FEATURES: — FULL AMCA CLASS 1 OPERATION — VENTED MOTOR COVER FOR WEATHER PROTECTION — UL762 LISTED FOR RESTAURANT DUTY - UPBLAST DISCHARGE DIRECTS AIR AWAY FROM FLOOR — CONTINUOUSLY WELDED HOUSING -- CLEANOUT DOOR WITH LATCHES PROVIDE EASY ACCESS WITHOUT TOOLS --- 2" GREASE DRAIN WILL NOT CLOG OPTIONS: HEAT SLINGER SHAFT SEAL EMERGENCY DISCONNECT SWITCH VIBRATION ISOLATORS V 23 3/8 SHAFT DIA. 1 7/16 APPROX SI- .IPPING 499 HH 10 W 4 BI UL762 Utility Set REV. #4 01/07/2005 FF 60 FAN INFORMATION ELECTRICAL PACKAGES ELECTRICAL PREWIRE PACKAGE DRAWING NUMBER ' .31011028 JOB NAME Panda Express - Tukwila WA (M1 --08 -1189, JOB NUMBER 691120 • CONTROL INPUT 120VAC H1 =LINE, N1= NEUTRAL 15A BKR - DO NOT WIRE TO SHUNT TRIP 8 REAK ER 2 3 4 5 6 R1 -1 8K NC �� NO 7 8 9 10 11 12 13 14 LIGHT INPUT 120VAC H2-H5=UNE, N2 -N5= NEUTRAL 15 15A BKR LS-01 B, B BK 0 .LR H 16 17 18 INPUT 3 WIRE 3 PHASE 19 20 21 22 23 24 H1 FS-01 -- z - 5 Ed_ • (Fan Switch Shown Installed) Al ST -X OL -X -0- OR Alott2 96,95 WH R3 0 WH 3 PHASE 460V ST -1 OL- 71 1 L2 T2 T2 22 L3 T3 T3 GR DATE 11/21/2007 DRAWN BY 3 Phase w/ 1 Exhaust Fan, Relay w/ 2 --DPDT On /Off w/ Supply Fan, Exhaust on in fire condition Label Description ST Starter FS Fan Switch Lighted MS MicroSwitch ( Ansul/ yroChem) R1 Relay DPDT LS Light Switch (1400W max) L Hood Li ht(s) GP General - Purpose Relay DPDT TX Transformer C Contactor GR Ground AF Air Flow Switch Spare Relay Contacts C -RD N0 -BL NC -PR 1 NC 3 4 NO 6 7 COMA. MS MS - MicroSwitch Ansul Pyrochem C -RD C -RD NO -BK NO -BK NC -BR NC -BR SPARE RELAY CONTACTS CAN BE USED TO CONTROL ITEMS REQUIRING SHUT DOWN WHEN A COIL B THE FIRE SYSTEM DISCHARGES, SUCH AS SHUNT R1 -R5 TRIP, SIGNALS, ETC... RELAY Snare Relay Contacts R2 - TERMINAL FOR FIELD NC C WIRING TO BUILDING FIRE PANEL DRY CONTACTS FOR SIGNAL. ONLY giEL NO NO N05 NC5 C5 G — �Ngfi - --VDNC6 --D C6 a NC 2 -2 C N R3 -1 C CONTACTS 5 & TURN ON & OFF WITH THE SUPPLY FAN. MS -2 eN C2 NC C 2N C2 a N0 JJJ ®© PH Volt 460 6.4 BREAKER INEM Motor Exh -1 NQTE$ - - - -- DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLACK YIN - YELLOW BL - BLUE GY -- GRAY BR - BROWN PR - PURPLE OR - ORANGE OR /BL - ORANGE /BLUE RD - RED (STRIPE) WH - WHILE BL /RD - BLUE /RED (STRIPE) RD /GN — RED /GREEN (STRIPE) DRAWING SHOWN DE- ENERGIZED NOTE IF WALL MOUNT PREWIRE, OR FIELD INSTALLED FIRE SYSTEM MICROSWITCH, THE TERMINALS SHOWING FACTORY WIRING MUST BE FIELD WIRED. 12 x 18 x 6 Box CURB ASSEMBLIES FAN OPTIONS APP ROVED c RECEIVED CITY OP 11 IKwlL Aim 9 Q nnn9 '.r... .., Luu AP% AM SNMAIMISMAIMI AIIMMIIII :=.:l■ — dMw■=► ∎ rr ■ Limp. iff ii Air RE , iff■ MM. ■ MOWN ItiN= 4 1/ if vr an∎A e we r a — — — ,rwnnr SOUTHERN CALIFORNIA REGIONAL OFFICE 17910 SKYPARK SUITE 210, IRVINE, CA 92614 PHONE: (949) 660 -7701, (800) 967-7701-FAX: (949) 660 -7702 -Visit us at www.captiveair.com PANDA RESTAURANT GROUP INC. 1683 Walnut Grove Ave. Rosemead, California 91770 Te Iephon 626. - IciQ.G8Q8 Facsimile: 626.312.8288 All ideas, designs, arrangement and plans indicated or represented by this drawing ore the property of Panda Express Inc. and were created for use on this specific project. None of these ideas, designs, arrangements or plans may be used by or disclosed to any person, firm, or corporation without the written permission of Panda Express Inc. REVISIONS: ISSUE DATE: DRAWN BY: PANDA PROJECT #: M1- 08 -D1189 HYC PROJECT #: CPC0719 ARCHITECT : 1683 WALNUT GROVE AVE-, SUITE 11301 ROSEMEAD, CA 91770 TEL 626.280.9188 FAX: 626.280.9189 E -MAIL INFO ©CALARC.NET PANDA EXPRESS WESTFIELD SOUTHCENTER SPACE NO. EC -10 633 SOUTHCENTER PKWY., TUKWILA, WA 98188 M -3.2 HOOD DETAIL PLAN ZACM Are Projoct107 Project -CAL Arc107 -1 PX concatrucllnn doepnen 1170705 PX South Center Mall, Tukwila, WA M1-08 -a1189 MEP Only117070 1lJ1YC ➢744- CAPAwg, 102&29071k09:33 PM, ace TDS4001x pe3