Permit M07-268 - WESTFIELD SOUTHCENTER MALL - LIMITED TOO
LIMITED TOO 1046 SOUTHCENTER MALL M07 -268 Parcel No.: Address: Suite No: doc: IMC-10/06 Tenant: Name: Address: Owner: Name: Address: Furnace: <1001C BTU > 100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial Contractor: Name: DEJAGER CONSTRUCTION INC Address: 75 60TH ST SW , WYOMING MI Contractor License No: DEJAGI *233K3 Value of Mechanical: $15,000.00 Type of Fire Protection: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 1046 SOUTHCENTER MALL TUKW LIMITED TOO 1046 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: SARAH NIELSEN Address: 1120 E 80 ST SUITE 211 , BLOOMINGTON MN DESCRIPTION OF WORK: HVAC SYSTEMS FOR TENANT IMPROVEMENT FOR NEW MALL SPACE MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: Fees Collected: $327.20 International Mechanical Code Edition: 2006 EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M07 - 268 Phone: Phone: 800 -541 -0821 Phone: 206 - 244 -2537 Expiration Date: 01/16/2010 M07 -268 05/22/2008 11/18/2008 Boiler Compressor: 0-3 HP/100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30-50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 05-22 -2008 Permit Center Authorized Signature: Signature: Print Name: doc: IMC-10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http:• / /www.ci.tukwila.wa.us c/e6. 4b ���'�Sa -r Permit Number: M07 -268 Issue Date: 05/22/2008 Permit Expires On: 11/18/2008 a/ Date: S - ?") 8 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of • o k. I am authorized to sign and obtain this mechanical permit. Date: C7 8 This permit shall become mill and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende< or abandoned for a period of 180 days from the last inspection. M07 -268 Printed: 05-22 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Parcel No.: 6364200010 Address: 1046 SOUTHCENTER MALL TUKW Suite No: Tenant: LIMITED TOO Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -268 Status: ISSUED Applied Date: 12/07/2007 Issue Date: 05/22/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M07 -268 Printed: 05-22 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 - 3670) is required for this project. 19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -268 Printed: 05-22 -2008 Signature: Print Name: doc: Cond -10/06 es 3 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. .,p/Al 1 Date: Z M07 -268 Printed: 05-22 -2008 Site Address: -4 So-et Tenant Name: l irnikerk Tian Property Owners Name: v.IPstBeit C 'rian Mailing Address: i14001 Nit %- ce tint APVnra, L.OS ' ° "y lei C'P 4cOZS City E -Mail Address: 4xl Qk Pr - Sri e . CDvv1 Company Name: T. Q. t . Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa. t�.s +246 (0 Contact Person: E -Mail Address: Contractor Registration Number: Company Name: 9rery rock AraN Ne rt5, \ arC. Mailing Address: (oA3h sst.,1 R�O�CIi� Contact Person: St r\i e✓ Ke itln Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** E -Mail Address: �1(e Ws P S1t1renr vv+r-. Conn Contact Person: E -Mail Address: Q:Mpplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Mechanical Building Permit No. f " M Permit No. vt0 _ lip Plumbing/Gas Permit No. T6,0 '7 " Public Works Permit No. Project No. ( (For office use only) King Co Assessor's Tax No.: . ti ka) C> Suite Number: 4 Floor: New Tenant: ® Yes ❑ ..No State CONTACT PERSON - who do we contact when your permit h ready to be issued Name: r o,34 h l i e \ S e _ r Day Telephone: $opl c -t Zip Mailing Address: Az° font S SA ee.k, 2 , (A \oo+tv bfl Mr.1 SST LC) Zip City State Fax Number: °Z 18'54- 44 oct GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) State Zip City Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD -All plans must be wet stamped by Architect of Record vntesterv■lle bM 4% City State Zip Day Telephone: Cr; t4IS4S- 1 -4SSa Fax Number: Cc14 1 Sag '�k5c ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: tier- Ccir s- AstnrkS Mailing Address: 111 C S httl9 Czoiss(r. ©C ism_ SO1- 1' c. i*L lR Weskerv1\ke del 43081 City State Zip Day Telephonef4.141$R2 -1 %ckel Fax Number: ro 1 °i 14; 82 ' ISSN Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 11 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 7-- Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: City State Zip Valuation of Mechanical work (contractor's bid price): $ iS oe0 Scope of Work (please provide detailed information): 2.. new \/AV'.S r\eJt� dvictu.)01 c t FA.x. S corvt - cCAS • Z bciiiN. anm e.tery ixst co nS Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... ❑ Fuel Type: Electric ® Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Q:1App)cations\Forms- Applications On Line13 -2006 - Permit Application.doc Revised: 9 - 2006 bb Page 4 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A THO ! ED AGENT: Signature: i. v �� Date: Print Name: c'.xo - 14J:e-l=er Day Telephone: igc5ers -C$2.\ Mailing Address: %\20 Ecx t SCA . P t — +acre. Z \\ • IP\cc,cvl ■,+1��FOY1 It-41 S�'#Z City State Zip Date Application Expires: t 7-00 Date Application Accepted: Q: ApplicationsWorms- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh Staff Initials: Page 6 of 6 Parcel No.: 6364200010 Permit Number: M07 -268 Address: 1046 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/07/2007 Applicant: LIMITED TOO Issue Date: Receipt No.: R08 -01775 Initials: WER Payment Date: User ID: 1655 Balance: Payee: DE JAGER CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount ACCOUNT ITEM LIST: Descript ion doc: Receiot -06 Payment Check 178887 267.76 MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 267.76 Total: $267.76 Payment Amount: $267.76 05/22/2008 10:29 AM $0.00 2760 05/22 9711 TOTAL 415.76 Printed: 05-22 -2008 Receipt No.: R07 -02704 Payee: ELDER JONES ACCOUNT ITEM LIST: Descript ion PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M07 -268 Address: 1046 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/07/2007 Applicant: LIMITED TOO Issue Date: Initials: WER Payment Date: 12/07/2007 03:58 PM User ID: 1655 Balance: $267.76 TRANSACTION LIST: Type Method Description Amount Payment Check 50466 59.44 Account Code Current Pmts 000/345.830 59.44 Total: $59.44 Payment Amount: $59.44 5847 12/10 9710 TOTAL 1368.38 doc: Receiot -06 Printed: 12 -07 -2007 Project: 1 C( r A L; Y1.'‘ r - G Type of Inspection: 11,C.1 1 s U Address: 1vL1(e 044l( Date Called: Special Instructions: Date Wanted: 7- 2 L-1 -fie ireaU p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERK NO. (206)431 -367 Ell Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0 W/1 ' Date: 7- 2 Li 0S r /4c $ • 0 REINSPECTION FEE MIRED. (lrior to inspection, fee must be p . d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: Type of Inspection: 5,A., r..4- 5L- k- i'.,lt,401+ Address: /O 0)j9 MU Qa.Le-? Addy {SS Ao . t -- ecSS ‹,,vv1c.5 t , ,',.1 LAt- 1 a.m. p.m. Requester: W.0 -2. Q.e 4.. r91 d v' 00. 16 2 P,SU/ N is W I 1- 1,_ - i r i Project: . , L .trn1 � a Z Type of Inspection: 5,A., r..4- 5L- k- i'.,lt,401+ Address: /O 0)j9 Date Called: Special Instructions: Date Wanted: I , i i/ a.m. p.m. Requester: Phone No: p lie _ G ly e pig1 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' Ft 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspector: Vhv --zu$ (Date: // . rl $60.00 REINSPECTION FEE R'QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: , , . / // / Type of I pection: r / k -1 't/ Address: / 0 e/( 414 // Date Called: Special Instructions: Date Wanted: G -- oe ( t) P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit d 7"266 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 0- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS:.#/ /i1i a -4r cede; five J J S6 0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pa t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Proje : , /)77./; :-. r) Type o Inspection: . 4 /I - iA) Address: / )9 // 70.9 /f Date Calle Special Instructions: Date Wanted: 4 Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 .LJ Approved per applicable codes. !orrections required prior to approval. COMMENTS: / L?e 'ui , ,i i , /, , 7 Gt-IT e& J o, n-� � -1 vfze i e. 0 r . Sect Inspector: I $ 0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project:, L..,, r►.,.� -�d c72 Sprinklers: Type of In ect : e)ecsS i ,, sr Hood & Duct: Address. /0y 6 Suite #: S. C. C"1 i C- Contact erson: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Are Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS . 98188 206- 575 -4407 n Approved per applicable codes. Corrections required prior to approval. COMMENTS: St o k f - b D "rkd r{ , � } ae, Ys. c�- -- inspector: i?".5 �( Date: -2 /e e Hrs.: It $80.00- REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 FILE COPY permit NO. r r L is sublect to errors and omissions. ^. Mal-. 2(98 :unumnsnmilvmmuln 'mil v04 11., to44:44 : 4 4tee ,Vdti D. 8" -4 s• NO' ' • • " • • • . . . . Ft 9 i . = 1 I 1 - 0 z DEC 2 () DEC 07 2007 VtFi 0 1„ EXPIRES 6/10/ag' 41iffiltniii1XUIMMUMULUMmulratUtlaUtIti Project Info Project Address Limited Too - Southcenter Date 12/3/2007 633 Southc.nt.r For Building Department Use Seattle, WA 98188 Applicant Name: H g R Consultants, LTD Applicant Address: 171 Charring Cross Drive Applicant Phone: east.rvill., os 43081 Project Summary PRJ -SUM • 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 DEC 0 7 2007 Heating Equipment Schedule Equip. ID ID Brand Name Model No. 1 Capacity2 Btu/11 Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency VAV -1 CARRIER VpZT16T 17070 1100 NA 5 KW 17070 VAV-2 CARRIER V9E816T 17070 1100 NA 5 KW 17070 Mechanical Summary MECH -SUM 2004 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Indudes Plans 2004 Washington State NonresiaenIlal nergy..uu vvrr �Nnariw Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Revised May 2005 Project Info Project Address Limited Too - Sout:hconter 633 Southcenter Seattle, O. 98188 Applicant Name: rt s K Consultants, LTD Applicant Address: 171 Charring Cross Drive Applicant Phone: Westerville, Oa 43081 Date 12/3/2007 For Building Dept. Use Compliance Option Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID VAV -1 VAV -2 Brand Name' CARRIER CARRIER Model No. VPE816T VPET16T Capacity Btu/h 35478 35964 Total CFM 2190 2220 OSA CFM or Econo? NA NA SEER or EER NA NA IPLV NA NA Location Sales STOCK RM Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP /BHP Flow Control Location of Service DEC 0 7 1uut r`c; tlij r (.ir► i tlf available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Mechanical Permit Plans Checklist MECH -CHK 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 Project Address Limited Too - Southoenter 'Date 12/3/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements In the Washington State Nonresidential Energy Code. Applicability Code (yes, no, n.a.) Section Component ,Information Required Location ' on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule n. a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n. a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans 14-3. yea 1412.2 Deadband control Indicate 5 degree deadband minimum MS n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types 14-1 n. a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n. a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yea 1412.7 Balancing Indicate balancing features on plans MS -i n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n. a . 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n. a . 1413.2 Water Econo Doc Indicate clg load & water econoe & dg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n. a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary MS-i yes 1414.2 Duct insulation Indicate R -value of Insulation on duct MS-i yes 1415.1 Piping insulation Indicate R -value of insulation on piping MS-i 1416 Completion Requirements yes 1416.1 &2 Drawings & Manuals Indicate requirement for record drawings and operation docs. MS -i yes 1416.3.2 Air Balancing Indicate air system balance requirements MS n.a. 1416.3.3 Hydronic Balancing Indicate hydronic system balance requirements yes 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report Ns-1 n.a. 1424 Separate air sys. Indicate separate systems on plans yes Mechanical Completed and attached. Equipment schedule with types, Summary Form input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank MS-i yes 1442 Shut -off controls Indicate automatic shut -off MS-i yes 1443 Pipe Insulation Indicate R -value of insulation on piping MS -i n. a . 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n . a. 1453 Pool heater controls Indicate switch and 65 degree control . , r` , '"1•+ ° fiat. 1454 Pool covers Indicate vapor retardant cover ; ti. 4, i. '- J n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover DEC 0 7 ?ill hin State Nonresidential Energy code compliance rorm no is circled for any question, provide explanation: 7 1'i= i "ii�Jf1`I 111.: 4 I L. 05 -08 -2008 SARAH NIELSEN 1120E 80 ST SUITE 211 BLOOMINGTON MN 55420 RE: Permit Application No. M07 -268 1046 SOUTHCENTER MALL TUKW Dear Permit Applicant: City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current permit application files, it appears that your permit application applied for on 12/07/2007 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 06/04/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 06/04/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: fer Marshall t Technician Permit File No. M07 -268 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Faxf 706 - 4 - DEPARTMENTS: Public Works Complete Comments: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 PLAN RVIEW /ROU ACTIVITY NUMBER: M07 -268 DATE: PROJECT NAME: LIMITED TOO SITE ADDRESS: 1 046 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # 12 -07 -07 After Permit Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required r' )C �Z • �•07 Fire Prevention Structural ❑ Permit Coordinator ❑ SLIP Planning Division DUE DATE: 12 -11 -07 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 01 -08 -08 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License DEJAGI *233K3 Licensee Name DEJAGER CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600231433 Ind. Ins. Account Id 44406700 Business Type CORPORATION Address 1 75 60TH ST SW Address 2 City WYOMING County OUT OF STATE State MI Zip 49548 Phone 6165300060 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/23/1977 Expiration Date 1/16/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date DEJAGER, DAN 01/01/1980 MENKVELD, ROBERT 01/01/1980 DEJAGER, DAVE 01/01/1980 WOIDERSKI, DENNIS 01/01/1980 DEJAGER, RICHARD W 01/01/1980 01/01/1980 KROL, BRIAN A 01/01/1980 01/01/1980 LENARTZ, RICHARD A 01/01/1980 01/01/1980 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= DEJAGI *233K3 05/22/2008 5 raw 0 W co 7 W cc 0) T z RIB Z Z Q -J co co t W I— ac 0 a V —I LU I— I— I— aOt w J co�Ot/) MASTER UPDATE : 0221.2006 Il2Wa 1 EXPiaES 6/1010 M -1 DRAWING NUMBER: ? � • a a za Or /41 S tY 5 z 2 z le a cc cr O T J a co I. THE ENGINEER ASSURES HO RESPONSIBILITY OR LIAINUTY FOR THE USE of THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL-THIS BUILDING 115E IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESI;14 CRITERIA. HBK# 07164 ®DOM WATER V.JJELEV UNKNOWN 3 SAN VENT ELEV UNKNOWN H.C. LAV DRYWALL 8 ' —O n / Y\DOM WATER V:YELEV UNKNOWN 3 SAN VENT ELEV UNKNOWN GYP —BD 10 -0" /\EXHAUST DUCT \=/ELEV UNKNOWN 3DOM WATER - UNKNOWN () ZD —1 T —STAT 0 O 0 (I 75 LANDLORD ELECTRICAL RM — — — — 0 t. SD -6 350 SD -7 50 -i--I dCORRIDORI::: GYP- 9' -0 150 3D O SD -2 220 a SD -4 WIFE • ................. 10" 1 ZD 10 "m i2 "o DJACENT TENANT -3 • 1 0 "0 • • • i " o 12 "0 H.C. FTG. I l - - � --- - - - - - FTG. I _ — ROOIIs ��I I • I GYP —BD 12'-0" a 0 0 SALES 40 ADJACENT TENANT -3 MECHANICAL GENERAL NOTES 1 THE ABBREVIATION T.S.P. WHEREVER IT APPEARS IN THESE MECHANICAL AND ELECTRICAL DRAWINGS, SHALL REFER TO "TOO, INC.'S STORE PLANNING ". ANY REFERENCE TO TENANT'S, OR LIMITED TOO'S CONSTRUCTION MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO T.S.P. 2 THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL D I V I ONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3 THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT ANY MECHANICAL EQUIPMENT. THIS CONTRACTOR SHALL COORDINATE LOCATIONS AND REQUIREMENTS WITH THE GENERAL CONTRACTOR AND LANDLORD PRIOR TO BID. 4 RETURN AIR GRILLES AT STOREFRONT TO BE ORIENTED TO PREVENT VIEW INTO PLENUM FROM MALL. ALL OTHER RETURN AIR GRILLES ARE TO BE ORIENTED SO BLADE OPENINGS FACE WALL OR SOFFIT TO PREVENT VIEW INTO THE PLENUM. 5 MECHANICAL CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT BEING USED OR SHOWN TO REMAIN, IS FULLY REMOVED AND NOT ABANDONED. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 6 ALL 24 VOLT COMMUNICATION AND /OR SENSOR WIRING ASSOCIATED WITH THE HVAC CONTROL SYSTEM SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. ALL WIRING AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODES, LOCAL CODE AND LANDLORD REQUIREMENTS. MECHANICAL CONTRACTOR IS TO INSTALL PLENUM RATED SHIELDED TEMPERATURE CONTROL WIRING. MECHANICAL CONTRACTOR IS TO MAKE ALL FINAL WIRING CONNECTIONS TO THE TEMPERATURE CONTROL SYSTEM PER THE MANUFACTURER'S RECOMMENDATIONS. 7 MECHANICAL CONTRACTOR WILL PERFORM STARTUP ON ALL T.S.P. PROVIDED HVAC EQUIPMENT AND CONTROL SYSTEM. NO TEMPORARY HEATING OR COOLING FROM T.S.P. PROVIDED HVAC UNITS WILL BE PERMITTED WITHOUT PROPER STARTUP PROCEDURES AS OUTLINED IN THE INSTALLATION AND STARTUP BOOKLETS PROVIDED WITH THE HVAC EQUIPMENT AND APPROVAL FROM T.S.P. CONSTRUCTION MANAGER. 8 FIRE PROTECTION PLANS, SPRINKLER DRAWINGS, MUST BE ENGINEERED AND WET SIGNED BY A LANDLORD APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL JURISDICTION. SD -6 tri 250 !d glk SD -1 400 VA) -1 T —STAT N 'A 2610 NON -SALES LAY_ IN 12' —O 16 "0 12 "0 12 "0 0 Y9 U Q O C SUPPLY DUCT 14 VAV -1- ELEV UNKNOWN r 0 -J 0 16 "0 MED. PRESS. 1J 16 "0 MED. PRESS. y TYP SAN SEWER ELEV UNKNOWN X VAV -2 TYP) 0 0 0 0 0 o o 0 Q SD -2 300 X I� -- .... PRA • • • • 4 SD -2 300 CIO x RG -1 8 - 10 "0 20 "0 10 "a 12 "0 w /►+ 10 "0 16 "0 (TYP) (TYP) 10 \ / / 1 \ 10 "0 FTG. ROOM MECHANICAL CODED NOTES ® EXISTING UTILITIES (DUCTWORK, PIPING, CONDUIT, ETC.) TO REMAIN. TYPE, SIZE AND ELEVATION ARE AS NOTED. N O O rwr4 LANDLORD COMPATIBLE THERMOSTAT FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR AT 48" ABOVE FINISHED FLOOR. VERIFY EXACT LOCATION OF SENSOR WITH T.S.P.'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL PLENUM RATED SHIELDED, 24V CONTROL WIRE BETWEEN THERMOSTAT AND HVAC UNIT. ZONE DAMPER, TRANSFORMER, AND THERMOSTAT FURNISHED BY T.S.P. AND INSTALLED BY MECHANICAL CONTRACTOR. YOUNG'S REGULATOR: MODEL #4010 —P0 ROUND 2— POSITION DAMPER, THERMOSTAT T312, TRANSFORMER 0035 (24V/120/ 40VA). REFER TO SHEET E -1 FOR J— BOX LOCATION ACCESSIBLE IN PLENUM NEAR ZONE DAMPER AND INSTALL 24V/120V 40 VA TRANSFORMER. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL THREE CONDUCTOR PLENUM RATED SHIELDED, 24V CONTROL WIRE BETWEEN TRANSFORMER, THERMOSTAT AND DAMPER MOTOR AS DIAGRAMED ON MD-1. ELECTRICAL CONTRACTOR TO PROVIDE 120V POWER TO TRANSFORMER OFF NIGHT LIGHT CIRCUIT. INSTALL THERMOSTAT AT 48" ABOVE FINISHED FLOOR AS APPROVED BY T.S.P.'S CONSTRUCTION MANAGER. ' EXHAUST GRILLE LOCATED IN LOWER DRYWALL CEILING AT APPROXIMATELY 8'-O" A.F.F. RUN SHEETMETAL DUCT FROM DEVICE IN LOWER CEILING AND CONNECT TO LANDLORD EXHAUST DUCT. CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE AS SHOWN. FIELD VERIFY EXACT LOCATION OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEAN OUT AT CONNECTION TO LANDLORD'S MAIN AND COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR FINISH WITH T.S.P.'S CONSTRUCTION MANAGER. NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MINIMUM REQUIREMENT OF HOLDING 10 FT. FOR HOURS REFER T TA K DIAGRAM AND PLUMBING O W.C. C 0 TWO OU S TO S C D G D LUMB G SPECIFICATIONS FOR FURTHER INFORMATION. CONNECT NEW VENT LINE FROM PLUMBING FIXTURES INTO THE LANDLORD'S EXISTING VENT MAIN. FIELD VERIFY EXACT LOCATION OF LANDLORD'S EXISTING VENT PRIOR TO BIDDING. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. '7 CONNECT NEW COLD WATER LINE INTO THE EXISTING COLD WATER TAP. NOTIFY T.S.P.'S CONSTRUCTION MANAGER IF TAP IS SMALLER THAN SHOWN ON RISER DIAGRAM. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. FURNISH AND INSTALL WATER HAMMER ARRESTERS IN THE DOMESTIC COLD AND HOT WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM. WATER HAMMER ARRESTERS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE. 150 L 150 O 0 SD -2 240 SD -5 O RG -1_ O ----. O ) 0 0 0 0 SD - 2 1 "0 074 N 300 \ \ i3 —_ 0 GYP—BD 12' -0" 0 / / N / O • SD -2 300 X X RG= 2 r H 6'0 LAM —LITE 10' -9" 16 "0 VAV -1 T —STAT C) SALES GYP —BD 10 "o 12 "0 00Oa00 X \ ---------- e===== • u ADJACENT TENANT 10 "0 10 "0 TYP 0 0 X X INSTALL 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION. I I 1 1 I 1 1 I I 1 1 I I1 I1 I 1 1 5D -2 I 1 300 i I SD -2 300 a 0 0 O ADJACENT TENANT ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. ALL WATER LINES, VENT LINES, DUCTWORK, DRAIN LINES, SPRINKLER LINES, ETC. SHALL BE OFFSET BELOW PLATFORM AND CONCEALED IN WALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETC. THROUGH STORAGE SPACE ABOVE PLATFORM OR ABOVE ELECTRICAL EQUIPMENT. DASHED LINE AROUND HVAC EQUIPMENT REPRESENTS MANUFACTURER'S RECOMMENDED CLEARANCES FOR EQUIPMENT MAINTENANCE. IT IS THE MECHANICAL CONTRACTOR'S RESPONSIBILITY TO MAINTAIN SERVICE CLEARANCES THE FULL HEIGHT OF THE UNIT IN THIS AREA AND TO PROVIDE ACCESS TO THESE AREAS SUBJECT TO T.S.P. CONSTRUCTION MANAGER'S APPROVAL. IF FREE AREA CANNOT BE OBTAINED IN THIS LOCATION, IMMEDIATELY CONTACT T.S.P.'S CONSTRUCTION MANAGER FOR FURTHER INSTALLATION INSTRUCTIONS. AIR DEVICE TO BE USED FOR ACCESS TO EQUIPMENT LOCATED ABOVE CEILING. THIS CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3 —FEET VERTICALLY AND 2— FEET HORIZONTALLY IN ALL DIRECTIONS AROUND EQUIPMENT IS MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. IF THIS FREE AREA CAN NOT BE OBTAINED, CONTACT THE T.S.P. CONSTRUCTION MANAGER IMMEDIATELY. FAN POWERED VARIABLE —AIR— VOLUME PARALLEL BOX FURNISHED BY T.S.P. AND INSTALLED BY THE CONTRACTOR. CONNECT VAV BOX TO THE MAIN AIR DISTRIBUTION SYSTEM AS SHOWN. AWARDED CONTRACTOR MUST ARRANGE DELIVERY THROUGH DAN SCHONDELMAYER WITH TRANE NATIONAL ACCOUNTS, AT (866)415 -2499, WITHIN THE FIRST WEEK OF CONSTRUCTION TO SCHEDULE DELIVERY DATE. CONTRACTOR MUST VERIFY MODEL NUMBERS AND ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION. VERIFY BOX INLET AND OUTLET CONNECTION SIZES AND INCLUDE DUCT TRANSITIONS AND FLEX DUCT CONNECTIONS IN BID. • A I 1 - 1 1 11 1 1 1 1 1 1 1 I 1 1 1 1 11 1 1 I i 1 M WA ELE UNKNOWN VAV -1 TRANE MODEL 2,190 C.F.M. 1,100 C.F.M. PHASE, 60HZ. 5 KW ELECTRI VAV -2 TRANE MODEL 2,220 C.F.M. 1,100 C.F.M. PHASE, 60HZ. 5 KW ELECTRI R FACTORY — INSTALLED ACCESSORIES: 28 27 #VPEF16T PRIMARY AIR AIR FAN, 1 HP ECM MOTOR, 277 VOLT, 1 C HEATER, 480 VOLT, 3 PHASE, 60 HZ. fVPEF16T PRIMARY AIR AIR FAN, 1 HP ECM MOTOR, 277 VOLT, 1 C HEATER, 480 VOLT, 3 PHASE, 60 HZ. ELECTRONIC ACTUATOR DISCONNECT SWITCH CONTROLS TRANSFORMER FAN MOTOR FUSE, INDUCTION INLET FILTERS, HANGER BRACKETS, DOOR — INTERLOCKING NON —FUSED DISCONNECT, STANDARD 22 GAUGE CASING CONTRACTOR FURNISHED AND INSTALLED ACCESSORIES: DDC CONTROL SYSTEM PER THE LANDLORD'S SPECIFICATIONS. VERIFY THE EXACT MANUFACTURER OF THE VAV CONTROLS WITH THE LANDLORD. THERMOSTAT COMPATIBLE WITH LANDLORD SPECIFICATIONS. MECHANICAL CONTRACTOR SHALL FURNISH THREE SETS OF STANDARD AIR FILTERS. CONTRACTOR TO REPLACE FILTERS JUST PRIOR TO AIR BALANCE AND ONCE AGAIN AFTER FINAL STORE CLEANING IS COMPLETE. MECHANICAL CONTRACTOR SHALL FURNISH FLEXIBLE DUCT CONNECTIONS TO INLET AND OUTLET OF BOX. UNIT IS SUSPENDED FROM THE STRUCTURE WITH IN —LINE COMBINATION RUBBER AND SPRING VIBRATION ISOLATORS FURNISHED AND INSTALLED BY THE MECHANICAL F PY FILE It N �' Plan MON approval � ppt8L1 thorize ro trud► e. R = . Appval of the violation of Co 1S � � Y.i' {�IIY� Dl approved Field Etv Date: City of Tukwila BUILDING DIVISION MOE7Z8 L ... : EVARATE PEANgT REQUIRED FOR c3 Mecrartical V ectrica 1 [plu r Gas Piping City °l T I?S;ply `i!fR :'hf- - 3 7fi e m::sr tc thrs sr p of ) ' prior araprot . I of uk ila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review_ fees. j PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) THE FIRST YEAR LABOR WARRANTY WILL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR AND MUST BE INCLUDED IN THE BID. NO BID WILL BE ACCEPTED WITH THIS ITEM EXCLUDED. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECS., AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR T.S.P. SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. NOTE TO GENERAL CONTRACTOR: TRANE EQUIPMENT NOTED HAS BEEN PRE — PURCHASED BY TOO, INC. STORE PLANNING. WITHIN THE FIRST WEEK OF CONSTRUCTION, THE GENERAL CONTRACTOR OR THEIR MECHANICAL SUB — CONTRACTOR SHALL FAX TO: TRANE NATIONAL ACCOUNTS ATTN: DAN SCHONDELMAYER FAX NUMBER: 513- 772 -7281 PHONE NUMBER: 315- 432 -7246 THE FAX SHALL STATE THE PHONE NUMBER AND THE FAX NUMBER OF THE CONTACT PERSON RESPONSIBLE FOR SCHEDULING AND RECEIVING THE HVAC EQUIPMENT AND ACCESSORIES, DELIVERY ADDRESS EQUIPMENT AND ACCESSORIES ARE TO BE SHIPPED TO AND ANY SPECIAL SHIPPING INSTRUCTIONS REQUIRED. ALLOW A MINIMUM OF TWO WEEKS AFTER CONSTRUCTION STARTS FOR DELIVERY UNLESS SPECIAL ARRANGEMENTS ARE MADE PRIOR TO THE START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL SHIPPING COST INCURRED IF DELIVERY IS REQUIRED PRIOR TO THE STANDARD TWO WEEKS SCHEDULED. IF THIS INFORMATION IS NOT SENT TO TRANE NATIONAL ACCOUNTS, THEN THE EQUIPMENT AND ACCESSORIES WILL SHIP IN ACCORDANCE WITH THE PURCHASE ORDER DATE AND INSTRUCTIONS ISSUED BY TWEEN BRANDS, INC. STORE PLANNING AND THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR UNLOADING AND STORAGE OF EQUIPMENT UNTIL SUCH TIME AS REQUIRED FOR INSTALLATION ON PROJECT. STRUCTURAL ELEVATIONS BASED ON: FIELD SURVEY STRUCTURAL DRAWINGS STORE IS LOCATED ON LEVEL 1 OF 2 LANDLORD INFORMATION X HEIGHTS UNAVAILABLE FINISHED FLOOR TO BOTTOM OF DECK ABOVE IS APPROX. UNKNOWN FINISHED FLOOR TO BOTTOM OF LOWEST STRUCTURAL MEMBER (STEEL OR CONCRETE BEAMS/ JOISTS) IS APPROX. UNKNOWN ALL OTHER EQUIPMENT, PIPING, AND DUCTWORK ELEVATIONS ARE AS NOTED ON THE DRAWINGS. NOTE: CONTRACTOR IS TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID. DUCTWORK SHALL NOT BE FABRICATED OR ANY EQUIPMENT ORDERED PRIOR TO APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER. SPACE WAS NOT SURVEYED. p aNDLORD SHALL PROVIDE : VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. DEC 0 2007 A. NOTE 1. THE ABBREVIATION T.S.P. WHEREVER IT APPEARS IN THESE MECHANICAL DRAWINGS AND /OR SPECIFICATIONS SHALL REFER TO ' TWEEN BRAND STORE PLANNING, INC. '. ANY REFERENCE TO TENANT'S OR LIMITED TOO'S CONSTRUCTION MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO T.S.P. 2. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 3. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF THIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE THIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS_ 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK AND THE WORK OF THIS SUBCONTRACTORS WORK TO COMPLY WITH THE T.S.P. SCHEDULE AND THE PROJECT COMPLETION DATE. 5. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 6. REFER TO RESPONSIBILITY SCHEDULE ON THE MECHANICAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR. MATERIALS, EQUIPMENT. SERVICES, TOOLS, TRANSPORTATION. INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR T.S.P. SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE T.S.P. CONSTRUCTION MANAGER, AS REQUIRED_ 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT_ 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR I S RESPONSIBLE FOR Flay I SH I NG :'J ! NSTAU. I NG THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS. PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES. WHICHEVER IS MORE STRINGENT. C. CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES. ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY T.S.P. TO THE CONTRACTOR. D. LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2. FURNISH TO THE T.S.P.'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. E. TRADE NAMES. MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY T.S.P.'S CONSTRUCTION MANAGER PRIOR THROUGH SHOP DRAWING SUBMITTAL PROCESS, FOR ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO T.S.P. CONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR T.S.P. CONSTRUCTION MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND THE SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. F. GUARANTEE 1_ THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK. MATERIAL. OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY T.S.P.'S CONSTRUCTION MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. T.S.P_, INC. SHALL GUARANTEE ALL EQUIPMENT ONCE LCS CONTROL NUMBERS HAVE BEEN ISSUED. T.S_P_ SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY T.S.P., INC. AND T.S.P.'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID. G. RECORD DRAWINGS DIVISION 15 - MECHANICAL SECTION 15000 BASIC MECHANICAL REQUIREMENTS 1. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. B. C. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS. AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE STAMPED 'DO NOT REMOVE' SHALL BE PLACED IN A DRAWING TUBE LOCATED NEXT TO THE ELECTRICAL PANEL. SEE ARCHITECTURAL DRAWINGS FOR EXACT TUBE LOCATION. H. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS. AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS_ WHERE DRAWINGS. EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE T.S.P.'S CONSTRUCTION MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, T.S.P. CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. .I I• ED ION MANAGER AND THE LANDLORD ONE WEEK • • I TO THIS CONT SERVICE REQUIRED TO HVAC, PLUMBING AND SP CONTRACTOR CO . ( NOT APPLICABLE ) INCLUDE IN HIS 811 'ICESSARY PHASE OF THE STORE'S IN OPERATION. EDULE IN WRITING WI _'S DEMOLITION ( NOT APPLICABLE ) • If ►• I IS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATI T DEMOLITION OF EXISTING WORK AND THE DEMOLITION BY P. GENERAL CONTRACTOR. COORDINATE WITH THE G RAL CONTRA RR ANY EXISTING EQUIPMENT REQUIRED TO B EFT INTACT. THIS CONTRACT FOR, THE REMOVAL FIXTURES, PIPING. FANS, ETC. AND ASSOCIA THIS PROJECT, UNLESS SPE CONTRACTOR MUST VERIFY WIT ABANDONED EQUIPMENT, PIP REMOVAL. ROOF CURBS ALL EXTRANEOUS ITE APPLICABLE TO TH ROOF/WALL /FL STRUCTURE. THE FLOOR ARE TO LEVE K_ SLEEVES L. HANGERS L INCLUDE, AND WILL HELD RESPONSIBLE ALL EXISTING FIRE TECTION, PLUMBING UNITS, REFR RANT RECAPTURE, EXHAUST D ROOF S NOT TO BE REUSED ON Y NOTED OTHERWISE. LANDLORD ALL PRESUMED , AND EQUIPMENT PRIOR TO L VED AND THE ROOF PATCHED. ON THE ROOF NOT VED AND EXISTING OR EQUIPMENT IN NACCESSIBLE OR WALL . IF BE N THE SPACE EW WORK MUST BE ATCHHED /REPAIRED TO MAT ISTING ABANDONED PIPES, DUO MBEDDED IN CONCRETE, OR OTHERWIS CUT OFF AND SEALED BELOW OR WITHIN FL EN THEY ARE NOT TO BE REUSED IN THIS PROJ (RED BY LANDLORD OR CODES, ABANDONED PIPING AND CTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. •, OF IDED r- .4 ►• I- 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH ITS RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV' FOAM, '3M' FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS. CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3, HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. M. FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, T.S.P. SHALL HAVE AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. END OF SECTION 15000 DIVISION 15 - MECHANICAL SECTION 15200 PLUMBING A. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR. MATERIALS, EQUIPMENT. SERVICES. TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE,. BUT NOT BE LIMITED TO THE FOLLOWING: A. COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. B. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. C FIXTURES AND EQUIPMENT AS SCHEDULED. F. TESTS AND ADJUSTMENTS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. EQUIPMENT AND INSTALLATION 2. SANITARY PIPING 1. REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES. AMERICAN STANDARD, KOHLER AND CRANE ARE CONSIDERED ACCEPTABLE AS EQUALS. A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2' OR SMALLER MAY BE GALVANIZED STEEL. ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER TRADES_ SUBSTITUTIONS MIDST BE LISTED AND QUALIFIED IN BID. B. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES OF TENANTS IN SPACES BELOW, WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING_ A. B_ DICCII.IIL /.D MU/.LC. 3. POTABLE WATER PIPING SHALL BE AS FOLLOWS: A. BELOW GRADE: TYPE 'K', ANNEALED TYPE TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. B. ALL OTHER: TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95-5 TIN - ANTIMONY SOLDER 4. PIPING OF DISSIMILAR METALS MUST BE DI- ELECTRICALLY SEPARATED. 5. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY T.S.P.'S CONSTRUCTION MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE. IN AS FOLLOWS: SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDING EQUIPMENT SUPPLIED. 6. INSULATE ALL HOT WATER, COLD WATER PIPING WITH 1' THICK (K =0.23 75 'F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. 7. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2' ARMSTRONG 'ARMAFLEX' PIPING INSULATION OR TRUEBRO MODEL 102W "HANDI LAV GUARD' INSULATION KIT. 8. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES. AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 9. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. 10. CLEAN -OUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. WALL COVERS ARE TO BE STAINLESS STEEL AND FLOOR COVERS ARE TO BE BRASS. PROVIDE FLOOR COVERS WITH INSET AREA FOR CARPETED LOCATIONS. ALL CLEAN-OUT LOCATIONS SHALL BE APPROVED BY T.S.P.'S CONSTRUCTION MANAGER. 11. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 12. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: A. B. 13. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA_ USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE. 14. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. REFER TO PLANS TO DETERMINE IF WATER METER IS REQUIRED. GAS (WING ( NOT APPLICABLE ) U► • IN 'I - ' 4 I I- I URNISH AND INSTALL A COMPLETE GAS PIPING SYSTEM IF 1" LICABLE. REFER TO PLANS TO DETERMINE IF A GAS SYST• IS REI.IRED. GAS LI SHALL BE BLACK STEEL, SCHEDULE 40, AST A -53 OR ASTM A10 WITH MALLEABLE THREADED FITTINGS FI.' 2' AND SMALLER, WITH WELDED JOINTS FOR 2 -1/2' • II LARGER. 3. FURNISH AND IN LL A GAS COCK, DIRT LE , AND UNION CONNECTION TO EA PIECE OF EQUIPMENT PITCH PIPING AT A UNI DIRECTION OF FLOW. SUP REQUIRED BY LANDLORD CRI BY STANDARD INDUSTRY PRACTI J. GAS PIPING EXPOSED ON R INHIBITING PAINT. GAS PIPING INSTAL D IN RETURN AIR PL 'VMS SHALL BE SLEEVED AND VENTED OR DED IN ACCORDANCE WITH HE LOCAL GAS COMPANY, LI • CODE. AND APPLICABLE NFPA CODES. TESTING REQUIRE APPLI TACT AND COORDINATE GAS SERVICE. METER AND REGULAT QUIREMENTS WITH THE LOCAL GAS COMPANY AND THE MALL'S OPERATIONS MANAGER PRIOR TO BID. INCLUDE INSTALLATION C (1F GAS m rEP amp P •rIul arm IN Pin END OF SECTION 15200 DIVISION 15300 - MECHANICAL SECTION 15300 FIRE PROTECTION A. SCOPE OF WORK B. SHOP DRAWINGS TEST WATER PIPING AT 100 PSIG FOR SIX HOURS. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. C. EQUIPMENT AND INSTALLATION 1. SPRINKLER HEADS: 2. PIPING: F GRADE OF 1/4' IN 15 FEET UPWARD IN T PIP G EVERY 5 FEET. SUPPORT AS IA AS DETAILED ON DRAWINGS, OR ■ , WHICHEVER IS MORE STRINGENT. MUST E PAINTED WITH RUST- PURGING OF GAS PIPING SHALL BE DO NTS OF THE LOCAL GAS COMPANY, LOCAL LE NFPA 54 CODES. CO PER THE S, AND 1. THIS CONTRACTOR MUST USE A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR TO PERFORM ALL FIRE PROTECTION WORK. ALL COSTS MUST BE INCLUDED IN THIS CONTRACTORS BID. FIRE PROTECTION CONTRACTOR MUST COMPLY WITH ALL SECTIONS OF THIS SPECIFICATION AND INCLUDE SAME IN BID. 2. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES. TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING. INSTALLATION. COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT•BE-LIMITED TO THE FOLLOWING: A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE WITH EXISTING CONDITIONS, NFPA -13. LOCAL CODES, LANDLORD'S CRITERIA, AND INSURANCE CARRIERS FOR THE MALL AND LIMITED TOO. B. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. C. DESIGN DRAWINGS, HYDRAULIC CALCULATIONS, SUBMITTALS AND APPROVALS. D. PERMITS, FEES, AND CHARGES. E. TESTS AND TEST CERTIFICATES. F_ FIRE EXTINGUISHERS. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. CONTRACTOR SHALL USE APPROVED INDUSTRY FIRE SPRINKLER STANDARDS FOR REUSING EXISTING FIRE SPRINKLER BRANCHES AND SUBMIT CALCULATIONS TO T.S.P.'S CONSTRUCTION MANAGER UPON REQUEST OR REWORK SYSTEM TO T.S.P. CONSTRUCTION MANAGER'S SATISFACTION. 4. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. 1. THIS FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS FOR HIS WORK. SUBMIT SIX (6) COPIES TO GENERAL CONTRACTOR FOR APPROVAL. 2. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS. HYDRAULIC CALCULATIONS. HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. 3. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE FORWARDED TO THE LANDLORD'S AGENT AND TO T.S.P.'S CONSTRUCTION MANAGER. A. ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS IN EXISTING T.S.P. STORES ARE NOT TO BE REPLACED UNLESS NOTED OTHERWISE), U.L., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER CO., GLOBE, GRINNELL, RELIABLE, STAR, OR VIKING_ B. ALL SPRINKLER HEADS SHALL BE RATED FOR 165'F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. C. ALL SALES FLOORS HEADS ARE TO HAVE BE FACTORY APPLIED COLOR FINISH. VERIFY HEAD TYPES AND COLORS WITH T.S.P.'S CONSTRUCTION MANAGER AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. D. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: 1. 'SALES' AREA SPRINKLER HEADS IN CEILINGS ARE TO BE WHITE RECESSED PENDANT WITH WHITE ESCUTCHEON. BASE BID SHALL BE RELIABLE MODEL 'FI'. ALTERNATE BIDS MAY BE BASED ON VIKING MICROMATIC MODEL 'M' OR GRINNELL MODEL 'F972' AND MUST BE APPROVED BY THE T.S.P. CONSTRUCTION MANAGER PRIOR TO ORDERING AND INSTALLATION. 2. "NON- SALES' AREA SPRINKLER HEADS ARE TO BE PENDANT TYPE ROUGH BRASS FINISH. MANUFACTURED BY STAR, RELIABLE, GRINNELL. VIKING OR CENTRAL SPRINKLER CO.. 3. 'OPEN CEILING SALES' AREA SPRINKLER HEADS ARE TO BE WHITE UPRIGHT. BASE BID SHALL BE RELIABLE MODEL 'FI'. ALTERNATE BIDS MAY BE BASED ON VIKING MICROMATIC MODEL "M' OR GRINNELL MODEL 'F972' AND MUST BE APPROVED BY THE T.S.P. CONSTRUCTION MANAGER PRIOR TO ORDERING AND INSTALLATION. 4. "SALES' AREA SPRINKLER HEADS THAT ARE LISTED ON THE ARCHITECTURAL DRAWINGS TO BE PAINTED, ARE TO BE FACTORY PAINTED TO A FACTORY STANDARD COLOR. SUBMIT COLOR CHART TO T.S.P. CONSTRUCTION MANAGER FOR APPROVAL. 5. 'OPEN CEILING NON - SALES" AREA SPRINKLER HEADS ARE TO BE UPRIGHT TYPE ROUGH BRASS FINISH. MANUFACTURED BY STAR, RELIABLE, GRINNELL, VIKING OR CENTRAL SPRINKLER CO.. A. SCHEDULE 40. BLACK STEEL PIPE. ASTM A -53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B-36 -10-70 FOR WROUGHT STEEL PIPE. B. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. C. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER_ D. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD_ 3. A FIRE PROTECTION SYSTEM TAP IS NORMALLY FURNISHED BY THE LANDLORD. VERIFY IN FIELD PRIOR TO BID. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN 'SALES' AREAS AND 100 SQ. FT. IN 'STOCK' AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA AND LOCAL CODES IF MORE STRINGENT. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. 4. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH LIGHTS, DUCTS. PIPES, STORAGE DECK, ETC. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS. SPRINKLER LINES, LIGHTS. DIFFUSERS. GRILLES AND REGISTERS PRIOR TO INSTALLATION. 5. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. 6. FURNISH AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR. OR INSURANCE CARRIER_ COORDINATE LOCATION WITH T.S.P.'S CONSTRUCTION MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH - IN_ MECHANICAL SPECIFICATIONS 7_ WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS. PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. 8_ PROPERLY COMPLETED AND SIGNED 'SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES' SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND T.S.P.'S CONSTRUCTION MANAGER. 9. SPRINKLER HEADS LOCATED IN CEILINGS OR WALLS BELOW 8' -0' ABOVE THE FINISHED FLOOR AND ABOVE STORAGE DECKS ARE TO BE CONCEALED. 10. FURNISH AND INSTALL 10 LB. TYPE 'ABC' FIRE EXTINGUISHERS. WITH CABINETS IF REQUIRED, AND AT LEAST A '2A1OBC' RATING_ LOCATIONS TO BE ESTABLISHED IN THE FIELD BY T.S.P.'S CONSTRUCTION MANAGER AND THE LOCAL FIRE PROTECTION OFFICIAL. MAXIMUM TRAVEL DISTANCE BETWEEN EXTINGUISHERS SHALL BE 75 FEET OR LESS AS REQUIRED BY LOCAL CODES. END OF SECTION 15300 DIVISION 15 - MECHANICAL SECTION 15500 HEATING, VENTILATION, AND AIR CONDITIONING A. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL SYSTEMS AS SWAN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. HVAC UNITS, EQUIPMENT, AND APPURTENANCES (UNLESS NOTED OTHERWISE). B DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. F. TESTING, ADJUSTING, AND BALANCING. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOBSITE AND EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE. COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM. MATERIALS. AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES TO MEET STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. HVAC EQUIPMENT 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED BY T.S.P. AS SCHEDULED UNLESS NOTED OTHERWISE. REFER TO PLANS FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES. APPURTENANCES. AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. 4. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO PROTECT ENTIRE UNIT. PROVIDE CONDENSATE PUMPS, AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. C. EQUIPMENT FURNISHED BY TWEEN BRAND STORE PLANNING, INC. 1. THE FOLLOWING EQUIPMENT IS FURNISHED BY T.S.P. AND INSTALLED BY THIS CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. REFER TO RESPONSIBILITY SCHEDULE AND PLANS FOR APPLICABILITY. A. HVAC UNITS RBI • _ _ D. DIFFUSERS, GRILLES AND REGISTERS. E. TEMPERATURE CONTROLS. 2. ALL DUCTWORK, ROOF OPENINGS AND CAPS NECESSARY TO PROVIDE A COMPLETE TOILET EXHAUST SYSTEM SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. D. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO JOB SITE VISIT AND APPROVAL BY THE GENERAL CONTRACTOR. A SKETCH MUST BE SUBMITTED INDICATING SIGNIFICANT DEVIATIONS FROM DESIGN AND MUST BE APPROVED BY T.S.P.'S CONSTRUCTION MANAGER PRIOR TO FABRICATION OR INSTALLATION. 2. EXCEPT AS OTHERWISE INDICATED. FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA 'HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. WHERE OTHER CODES ARE ENFORCED, (IE. WC, BOCA, ETC.) USE THE MOST STRINGENT CODE FOR DUCT CONSTRUCTION STANDARDS. 3. EXCEPT WHERE OTHERWISERTNDICATED, CONSTRUCT MCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: 2' W.G., POSITIVE RETURN AND EXHAUST DUCTS: 2' W.G., NEGATIVE EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: CLASS B - 3' W.G. RETURN AND EXHAUST DUCTS: CLASS C - 2' W.G. IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. 4. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCKSEAM CONSTRUCTION FOR ALL SIZES 14' DIAMETER AND LARGER. ROUND DUCTWORK SIZES 13' DIAMETER AND SMALLER MAY BE SNAP- - LOCK CONSTRUCTION. ALL SNAP -LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL WITH SPOT WELDED AND BONDED CONSTRUCTION. DUCTWORK SHALL BE AS MANUFACTURED BY UNITED MCGILL, SEMCO, OR APPROVED EQUAL. 5_ ROUND SPIRAL GALVANIZED STEEL DUCTWORK MAY BE USED IN PLACE OF RECTANGULAR DUCTWORK WHEN ABOVE CEILING CLEARANCES PERMIT AND EQUIVALENT FREE AREA IS MAINTAINED, WITH THE FOLLOWING EXCEPTION; ALL SUPPLY AND RETURN DUCTWORK WITHIN 15 FEET OF THE AIR HANDLER MUST BE RECTANGULAR AND INTERNALLY LINED. WHERE ROUND DUCT SUBSTITUTION WILL TAKE PLACE, SUBMIT A SKETCH AND CHART SHORING EQUIVALENT ROUND CONVERSIONS OF RECTANGULAR DUCTWORK TO T.S.P. CONSTRUCTION MANAGER'S FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION. 6. AS A MINIMUM, CROSSBREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/8' WIDE X 3/16' DEEP ON 12' CENTERS TO PREVENT VIBRATIONS, REGARDLESS OF DUCT GAUGE. 7. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN All RIGHT ANGLE ELBOWS OVER 36' IN LENGTH. INSTALL FACTORY MANUFACTURED SINGLE THICKNESS TURNING VANES IN ALL OTHER ELBOWS. 8. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 9. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 1/2'X1 -1/2" X1 /8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 10. ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2' WIDE, GLASS - FIBER- FABRIC REINFORCED TAPE. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS_ LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. 11. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 12. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 13. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS. AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY T.S.P.'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WHEN WITHIN 3' -0' OF DEVICE. 14. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. VAV BOX, DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. REFER TO DETAILS. E. MEDIUM PRESSURE DUCT 1. WHERE DUCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS FOR A PRESSURE RATING OF 4 INCHES WATER COLUMN MINIMUM OR GREATER AS REQUIRED BY LANDLORD. 2. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE DUCT AND WITH THE LANDLORD'S CRITERIA. 3. CONNECTIONS TO THE LANDLORD'S MEDIUM PRESSURE DUCTWORK SHALL BE MADE WITH 'LO -LOSS' SADDLE TEE TAPS BY UNITED MCGILL CORP., OR AS OTHERWISE REQUIRED BY THE LANDLORD_ 4. ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS SECTION, WITH THE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK MUST BE WRAPPED INSULATION, NOT LINED. F. VIBRATION ISOLATION DEVICES 1. VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS. ETC.) AND STRUCTURE. 2. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 3. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID 'GROUNDING' THE ISOLATOR. 4. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 5. CONSULT MANUFACTURER FOR APPLICATION DATA. G. FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS. ETC.) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE -COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. H. FLEXIBLE AIR DUCT 1. FLEXIBLE AIR DUCT SHALL BE 1' INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC. CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS ON DRAWING MD-1. FLEXIBLE AIR DUCT MAY ONLY SE USED IN VERTICAL APPLICATIONS WITHOUT PRIOR APPROVAL FROM T.S.P.'S CONSTRUCTION MANAGER UNLESS NOTED OTHERWISE. 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5' -0" IN LENGTH AT ANY ONE LOCATION. I. SUPPLY AIR TAKE -OFF FITTINGS 1. FURNISH AND INSTALL CONICAL OR 'BELL - MOUTH' TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALL PER MANUFACTURER'S INSTRUCTIONS AND DETAILS ON SHEET MD-I. J. DAMPERS 1. FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. 2. OPERATING HANDLES ON ALL DAMPERS SHALL BE TAGGED WITH A MINIMUM 18' LONG ORANGE MARKER TAPE. COLLARS MUST BE INSTALLED OVER EXTERNAL INSULATION TO ALLOW FREE MOVEMENT. SEE ADDITIONAL DETAILS ON MECHANICAL DETAIL DRAWING. 3. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, A YOUNG'S REGULATOR DAMPER SHALL BE USED. CONTACT YOUNG REGULATOR COMPANY AT (216) 663 -5646. UNITS SHALL BE ORDERED THREE WEEKS BEFORE INSTALLATION TO ALLOW FOR DELIVERY LEAD TIME. 1 I 1. F AND INSTALL FIRE DAMPERS OR SMOKE /FIRE D- i' = WHERE INDICA ' OR REQUIRED BY CODES_ DAMPERS SHALL ? IESIGNED FO HORIZONTAL '- VERTICAL FLOW OF AIR AS RE I - N D. FIRE DAMPER SHALL BE UL LAB -I TO MEET ULf555 • II • ET ALL CODE REQUIREMENTS. SMOKE :E DAMPERS '-LL BE UL LABELED TO MEET ULf555S AND MEET ALL CII ' I. •EMENTS. 2. FIRE DAMPERS SHALL A 165'F FUSIBLE DOORS AS N • 'Y. 3. F :• AND INSTALL ALL NECESSARY FRAMING AND SLE FOR AMPER MOUNTING PER UL AND CODE REQUIREMENTS. SEE DET ON SWEET MD 1. L. DUCTWORK INSULATION 1. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN '1STRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES_ INSULATION MUST COMPLY WITH NFPA 90A. 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. ALL SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK SHALL BE INTERNALLY INSULATED WITH 1' THICK, 1 -1/2 LB. DENSITY LINER (C =0.28 I:0 75'F). WHEN A COMPLETE DUCTED RETURN AIR SYSTEM IS INDICATED ON THE DRAWINGS, ONLY THE 15' --0' OF THE RETURN AIR DUCT CLOSEST TO THE AIR HANDLING UNIT IS TO BE INSULATED. LINER IS TO HAVE A COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACNA AND THE MANUFACTURER 70 PREVENT LINER SEPARATION FROM THE DUCT. ALL TRANSVERSE EDGES TO BE COATED WITH ADHESIVE. 3. ALL ROUND DUCTWORK, OUTSIDE AIR DUCTWORK AND MEDIUM PRESSURE DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1 1/2' THICK, If DENSITY (R=5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. I IYDRON I C f I P I NG _ PI ING - I • - APPLICABLE ) THE BLAD UT OF THE AIRSTREAM AND AS MINIMUM. F AND INSTALL ACCESS ( NOT APPLICABLE ) • , I • 11 I FURNISH AND INSTALL A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC STEM IS REQUIRED. A. • IRONIC PIPING FOR CHILLED WATER, CONDENSER ATER /OR HEATING WATER SHALL BE ASTM A -120, RI EDULE 40, E BLACK STEEL PIPE WITH PLAIN ENDS. I :TALL STEEL PIP WITH WELDED JOINTS WHERE PIPE IS 2- 2 INCH AND LARGE INSTALL STEEL PIPE WITH THREAD -I JOINTS AND FITTINER OR INSTALL TYPE 'K' ANNEALED EMPERED COPPER TUBE WI SILFOS JOINTS FOR 2 INCH • 'I SMALLER PIPE. ti TRI UNIONS BETWEEN IMI AR T PROVIDE D LECTRIC UN ONS BETWEE D L METALS. ALL PIPING LL BE IN STRICT CONF"'4 - CE WITH ASTM, ASA, AND L LORD'S REQUIREMENTS WHICHEVER IS MOST STRINGENT. IONS OR FLANGES T BE USED AT EQUIPMENT CONNECTIONS WH E SERVICE OR •' (VAL MAY BE REQUIRED. B. ALL PIPING AND ' IPMENT R • BE PRESSURE TESTED WITHOUT LEAKAGE A A MINI . PRESSURE OF 125 PSI. C. ALL HYDRONIC PIPINN AND EI..IPMENT CONNECTED TO THE HVAC PIPING SYSTEM SHALL , E ANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE S ' ER SCREENS. FILL TENANT'S SYSTEM WITH DOMESTIC W 'ER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO CI'k TION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NO FILL TENANT'S SYSTEM WITH WATER FROM THE LANDLORD': SYSTEM NLESS SPECIFICALLY INSTRUCTED TO DO =I FROM TH LANDLORD'S FIELD REPRESENTATIVE. D. PRIOR TO CONNE ION TO THE LAN ORD'S SYSTEM, CONTRACTOR -LL OBTAIN WRITTEN FIRMATION FROM THE LANDLORD'S F ELD REPRESENTATIVE, HAT ALL TESTING, FLUSHING, PROPER FILLING OF TH TENANT'S SYSTEM HAS BEEN COMP ETED IN ACCORDANCE TO THE ANDLORD'S REQUIR NTS AND THAT THE TENANT'S TEM IS READY TO BE CTED TO THE LANDLORD'S SYSTEM. VALVES A. G• E VALVES, 2 -INCH AND SMALLER: CLASS 150. BODY AND NION BONNET OF ASTM B 62 CAST BRONZE WITH T . OR SOLDER ENDS, INTEGRAL SEAT, RENEWABLE SOLID B WEDGE DISC, RISING STEM, SCREWED BONNET AND RE- `'CKABLE UNDER PRESSURE. BALL VALVES ARE ACCEPTED AS AN I AL SUBSTITUTION. B GATE VALVES, 2 -1/2 INCH AND LARGER: CLASS 125 CAST IRON BODY, RENEWABLE BRONZE SEATS AND SOLID WEDGE DI , RISING STEM, FLANGED ENDS. AND RE- PACKABLE UNDER ( NOT APPLICABLE ) C. SWING COCK VALVES, 2 -INCH AND SMALLER: CLASS 150, CAST BRONZE BODY AND CAP CONFORMING TO ASTM B 62 WIT HORIZONTAL SWING, Y- PATTERN, RENEWABLE BRONZE DISC, AND HAVING THREADED OR SOLDERED ENDS. SWING CHECK VALVE, 2 -1/2 INCH AND LARGER: CLASS 5 CAST IRON BODY AND BOLTED CAP, HORIZONTAL SWING, RENEWABLE BRONZE DISC, FLANGED ENDS AND CAPABLE IF BEING REFITTED WHILE THE VALVE REMAINS IN THE INE. E. «I R'INATION BALANCING AND SHUT -OFF VALVES: B'LL & Ii ETT CIRCUIT SETTER WITH LOCKING SET POI . A CI "CUIT SETTER BALANCE WHEEL MUST BE INCLUI D WITH 0 & M ENUAL. TACO OR GRISWOLD ARE CONSIDERED •S EQUAL. PIPING SPE•IALTIES A. PRESSU'• TEMPERATURE TEST PLUGS (''PET S PLUG) - 1/4 INCH NPT ITTINGS TO RECEIVE EITHER TEMPERATURE OR PRESSURE "IBE, 1/8 INCH O.D. FITT NG AND CAPS SHALL BE BRASS W H VALVE CORE OF HORDE , RATED AT 400 PSIG, 0'F TO 200' B. STRAINERS - " PATTERN STRAINS 125 P51G, CAST IRON BODY WITH PER E•-TED STAINLESS TEEL SCREEN, THREADED FOR 2 INCHES • ; SMALLER, FL ED FOR 2-1/2 INCHES AND LARGER. SCREEN ►' ENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INCH FOR m ILLED OR CONDENSER WATER. PROVIDE WITH BLOWDO 1 VAL WITH E END FITTING. C. THERMOFLO INDICATOR BE & GOSSETT MODEL 'TFI'_ INSULATION A. ALL HYDRONIC PIPING FI ILLED WATER AND /OR HEATING WATER (NOT INCLUDINI COND. R WATER UNLESS SPECIFICALLY NOTED @THERWI ), VALVES, FITTINGS, AND ACCESSORIES SHALL E INSULA D. FOR PIPE SIZES UP TO 2 INCHES, INSULATE ITH 1 INCH HICK (K=0.23 M 75'F) FIBERGLASS INSU TION WITH ALL SERVICE JACKET AND VAPOR BARRIER. FOR '•IPE SIZES 2-1/2 NCHES AND LARGER, INSULATE WIT 1 -1/2 INCH THICK =0.23 Oil 75'F) FIBERGLASS SULATION WITH ALL S VICE JACKET AND VAPOR BARRIER. B. INSULATII AT ALL HANGERS FOR PIP( LARGER L BE HARD AND NON-0OMPRE C. ALL IN . ATION SHALL HAVE A FLAME SP MORE T 25 AND A SMOKE DEVELOPED RAT THAT :0 TO CONFORM WITH THE REQUIREMENT D. PROV DE ZESTON OR EQUAL INSULATION FITTI TE , ELLS OR SPECIALTY FITTINGS. GE INSTALLATION A INSTALL WATER MAINS WITHOUT PITCH. USE ECCENT IC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE IP OF PIPES AT SAME ELEVATION. BRANCHES TO UNITS BELOW MAINS TO BE TAKEN FROM BO OM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWNWARD TOW UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN F TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN l TO 10 FEET. C. SEE MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. • El •4 • • • I. I I. I •, I 14" I- THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN THE INDOOR FAN UNITS OUTDOOR FAN UNITS, IF APPLICABLE. PING A. REFRIGERANT PIPING SHALL BE TYPE 'L HARD DRA TUBING (ASTM B88). TUBING SHALL BE CLEAN, ITROGEN CHARGED. B. FITTINGS AND JOINTS SHALL BE WROUGHT B'I E (ANSI B16.22). ALL COPPER TO COPP SHAL BE BRAZED WITH A COPPER - PHOSPHORUS OTHE JOINTS SHALL BE BRAZED WITH SILF C. ALL ELI ARE TO BE LONG RADIUS TYPE. INSTALLATION A. SLICT I O N L I DOUBLE SUCT CONDITIONS RECOMMENDATI B. BRAZE ALL JOIN UNIT AND WORKIN THE OUTDOOR UNIT BLEED SHALL BE US THE SYSTEM IS OPEN. SEALED BEFORE LEAVI PRESSURE TEST FOR LE PSIG. REDO LEAKING TIGHT. EVACUATE ENT MERCURY. CHARGE SYS GAS TO 245 PSI AND DETECTOR. ALL LE RESEALED UNTIL HEATERS 24 HOUR SURE ALL REFRI C. UPON COMPLETI PIPING INSUL INSPECTED B AUTHORITY D. INSULATE LINES INSULAT AND A ACCO HOT INSPE ION CONTRACTOR MUST PREPARE AND SUBMIT A COMPLETE PING SCHEMATIC TO THE LOCAL CARRIER FIELD REPRESENTA VE FOR APPROVAL PRIOR TO BEGINNING INSTALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST CALL E LOCAL CARRIER INSPECTOR FOR FIELD INSPECTION OF PERFORMED AT T.S-F. - -ENSE. ALL !INS FFOUND - TO BE INADEQUATE FOR PROPER PERFORMANCE BY CARRIER FIELD REPRESENTATIVE MUST BE CORRECTED AT NO ADDITIONAL CIUARCES TO T.S.P. O. LABELS /PIPE MARKERS WITH SILFOS- STARTING AT THE INDOOR TOWARD THE IiTDOOR UNIT. THE SEALS ON HALL BE B. EN LAST. A NITROGEN DURING L BRAZING AND ANY TIME ALL I•EN LINES SHALL BE CAPPED AND TH SITE DURING CONSTRUCTION. ITH AN INERT GAS UP TO 245 JO TS AND RETEST UNTIL SYSTEM IS I'N TEM TO 200 MICRONS OF EM TH 25 PSI OF R -22 AND A INERT ETEST •YSTEM WITH HALIDE LEAK ING JOI S MUST BE COMPLETELY LEAKS EXI '. TURN ON CRANK CASE PRIOR TO ST••TING COMPRESSOR TO BE RANT LIQUID I OUT OF THE COMPRESSOR. OF TESTING, BU :EFORE THE REFRIGERANT ION IS APPLIED, TH PIPING MUST BE A REPRESENTATIVE OF E LOCAL GOVERNING NECESSARY. REFRIGERANT SUCTION LI '.S AND CONDENSATE WITH RUBATEX OR ARMSTRONG INCH THICK PIPE ON WITH FLAME SPREAD RATING 0 NOT MORE THAN 25 E DEVELOPED RATING OF NOT THAN 50 IN ANCE WITH INDUSTRY STANDARDS. DO T INSULATE THE AS (LIQUID) LINES OR ANY HOT GAS SS LINES IF (CABLE. 1. FURNISH AND INSTALL PIPE IDENTIFICATION MARKERS ON ALL PIPES INSTALLED UNDER THIS CONTRACT. MARKERS SHALL BE A MINIMUM OF 1 -1/2' X 8' AND IDENTIFIED IN ACCORDANCE WITH THE BACKGROUND AND LETTER COLORS ISSUED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). MARKERS SHALL BE MANUFACTURED BY CHAMPION AMERICA INC. 800 -521 -7000. OR EQUAL. 2. PIPING SHALL BE IDENTIFIED AS FOLLOWS: CHILLED WATER RETURN. CHILLED WATER SUPPLY, CONDENSATE, HOT WATER RETURN, HOT WATER SUPPLY, CONDENSER WATER RETURN, CONDENSER WATER SUPPLY. REFRIGERANT LIQUID, REFRIGERANT SUCTION. AND DIRECTIONAL ARROWS. ALL IDENTIFICATIONS MUST BE VISIBLE AT EQUIPMENT. P. CURBS AND STEEL FRAMING FOR SUPPORT Q. TESTING, ADJUSTING, AND BALANCING ( NOT APPLICABLE ) 2 1/2 INCHES AND IBLE. RATING OF NOT G OF NO HIGHER OF THE NFPA. FOR ALL .•1 --I -v COPPER ED AND ER OR CAST JOINTS LOY AND ALL 5 ALLOY. S SHALL HAVE ADEQUATE IFT TRAPS AND /OR N RISERS TO MEET THE EQUIREMENTS OF FIELD EQUIPMENT MANUFAC R'S 1. THIS CONTRACTOR WILL FURNISH AND INSTALL ALL NECESSARY CURBS AND STEEL FRAMING REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED OR IMPLIED ON THE DRAWINGS.. CURBS SHALL BE A MINIMUM OF 14' HIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED UNLESS NOTED OTHERWISE. INSULATE UNDER THE COMPRESSOR SECTION. ALL CURBS MUST BE INSTALLED SO THAT TOP OF CURBS ARE 'DEAD' LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. THIS CONTRACTOR MUST RECEIVE T.S.P. CONSTRUCTION MANAGER'S WRITTEN APPROVAL BEFORE ANY ADDITIONAL WORK TAKES PLACE. 1. TESTING, ADJUSTING AND BALANCING OF ALL:T.T)RK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO IS A CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY AND AS A MINIMUM SHALL INCLUDE THE INFORMATION AS SHOWN IN THE AIR BALANCE REVIEW CHECKLIST SHOWN BELOW. PAYMENT OF ALL COSTS FOR TESTING AND BALANCING SHALL BE INCLUDED IN THE BID. 2. ALL CHILLED OR CONDENSER WATER SYSTEMS AND ALL LANDLORD VAV SYSTEM REQUIRE A PRE -TEST TO OCCUR ONCE TAPS HAVE BEEN MADE TO THE LANDLORD'S SYSTEM AND WITHIN THE FIRST TWO WEEKS OF CONSTRUCTION. REFER TO DETAILS FOR PROCEDURE. 3. FINAL TESTING, ADJUSTING AND BALANCING REPORT MUST BE COMPLETE AND TURNED DYER TO T.S.P.'S CONSTRUCTION MANAGER 1 WEEK PRIOR TO MERCHANDISING DATE. 4. THE HVAC CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL DEVICES. VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM( POSITION, EXCEPT AS NOTED OTHERWISE. HVAC CONTRACTOR SHALL ALSO INSTALL A NEW SET OF FILTERS ONE DAY PRIOR TO MERCHANDISING. 5. BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5% OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES. BELTS OR PULLEYS NEEDED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO T.S.P. INC. 6. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. 7. THE BALANCE REPORT SHALL BE ON THE AABC NATIONAL STANDARD REPORT FORMS OR THE NEBB CERTIFIED REPORT FORMS AS PUBLISHED IN THEIR MOST CURRENT EDITIONS AND SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. B. C. D. E. F. G. H. I. J. K. L. 8. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO T.S.P.'S CONSTRUCTION MANAGER FOR APPROVAL. THE GENERAL CONTRACTOR SHALL VERIFY THE COMPLETENESS OF THE REPORTS PRIOR TO SUBMITTING TO T.S.P.. SUBMIT ONE COPY OF FINAL APPROVED AIR BALANCE REPORT TO MALL GENERAL MANAGER. 9. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED ON THESE DRAWINGS_ ALL SYSTEMS UNABLE TO BE COMPLETELY BALANCED AT THE TIME'OF ORIGINAL BALANCE MUST BE BALANCED IN FUTURE AT NO ADDITIONAL EXPENSE TO T.S.P. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT T.S.P. DEEMS NECESSARY AT NO ADDITIONAL COST TO T.S.P. END OF SECTION 15500 AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING. CONTRACTOR. COPY OF A CERTIFICATE OF CONFORMANCE WITH NATIONAL STANDARDS FOR THIS PROJECT. INSTRUMENTATION LIST WITH LAST CALIBRATION DATES. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AND VOLUMES SHALL BE MEASURED AT FULL COOLING WITH MINIMUM OUTSIDE AIR. RETURN /RELIEF /SMOKE EVACUATION AIRFLOW SHALL BE BALANCED AND MEASUREMENTS RECORDED BY PITOT DUCT TRAVERSE AT FULL ECONOMIZER AND POWER EXHAUST. WATER BALANCE DATA INCLUDING GPM WITH INLET AND OUTLET TEMPERATURE AND PRESSURE READINGS (WHERE APPLICABLE). MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. ALSO INDICATE IF DIFFUSER IS 3-WAY OR 2- WAY. DEC D 7 2O07 P :fi 6i C Nfcr n A U- i Imm 0) WASTER UPDATE : 0211.2006 - . - W 2-a. 1 a 0 62810 1 O � 44 i N A z z z a 0 MS -1 a X g Q I Z 0 g di s s THE MOWER ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORCIED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA. HBK # 07164 DRAWING NUMBER: