Loading...
HomeMy WebLinkAboutPermit M07-271 - WESTFIELD SOUTHCENTER MALL - GUESSGUESS 467 SOUTHCENTER MALL M07 -271 Tenant: Name: Address: Owner: Name: Address: City-of Tukwila Parcel No.: 6364200010 Address: 467 SOUTHCENTER MALL TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us GUESS 467 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA MECHANICAL PERMIT Contact Person: Name: LAUREN CHASE Address: 626 C ADMIRAL DR, PMB STE 120 , ANNAPOLIS MD Contractor: Name: HORIZON RETAIL CONST INC Address: 1516 S GREEN BAY RD , RACINE WI Contractor License No: HORIZRC072N5 DESCRIPTION OF WORK: INSTALLATION OF NEW DUCTWORK, DIFFUSERS, THERMOSTAT, AND VAV BOX. Value of Mechanical: $30,000.00 Type of Fire Protection: Furnace: <100K BTU >100X BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 2 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 410 544 -1700 Phone: Expiration Date: 04/15/2009 M07 -271 04/18/2008 10/15/2008 Fees Collected: $500.08 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP/ 100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 17 Thermostat 2 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 doc: I MC -10/06 M07 -271 Printed: 04 -18 -2008 Permit Center Authorized Signature: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and e . ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or erf f wor I am authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: IMC -10/06 Permit Number: M07 -271 Issue Date: 04/18/2008 Permit Expires On: 10/15 /2008 1 Date: ot-iti4! Date: 4 71 This permit shall become null and void if t work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -271 Printed: 04 -18 -2008 City of Tukwila Parcel No.: 6364200010 Address: 467 SOUTHCENTER MALL TUICW Suite No: Tenant: GUESS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -271 Status: ISSUED Applied Date: 12/11/2007 Issue Date: 04/18/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M07 -271 Printed: 04 -18 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (1FC 104.2) 18: An electrical permit from the City of Tulcwila Building Department Permit Center (206 - 431 -3670) is required for this project. 19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: Cond -10/06 * *continued on next page ** M07 -271 Printed: 04 -18 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us dab •'hRCKay pel Date: +12 M07 -271 Printed: 04 -18 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci. rukwila.wa. us 1 4 1 3 — Site Address: 3 Soc,TN c E41EIR 'Oak Tenant Name: VE,SS Property Owners Name: S,,ik rF IELt) locsL rtowl Mailing Address: / /601 Vol 14.314 14E 'BLVD Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Elec t-I 'DIE'S Al G Rocs t Mailing Address: /1S3 OGIVEYTE E)c Ecc.,Ttvr "Mitic AY 3v rr yap Contact Person 9AVe GL. VE( E -Mail Address: Gteaire'itta g'Peac#11)E.1 KAI& teaP ,JET Company Name .Anl V AIL A. At r 3 Mailing Address: $o1(o Contact Person:I Awl0AM- A. wI ELS�AI Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** E -Mail Address.MA4 DYNalac w) Q Ac:E/Rusc,Roc, l . Go /•-■ Q: ApplicationsWonns- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh • Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. (For o ice 'use, on King Co Assessor's Tax No.: o o Suite Number: /Sys (EAAEXA New Tenant: Lo,s An1661E.3 City GA State State . Zets i3 City Day Telephone3 /x/• 21. 1 4'o Fax Number: 314' • 7 21 -433 4/ /moo State Floor: I Yes ❑ .. No 9c0 ZS Zip CONTACT PERSON who do we contact when your permit is ready to be Issued ko rI '1!'P �/ C� ' Name: TM Day Telephone: 204e- 38 • 7 Mailing Address: 1 341 I46S7 JeJT 194w 1 P. • 3AT T F co Collt IA /6803 17SGiNG eixt -Tr n� parr , E -Mail Address: T1( tA/E+ &GoPtcAST. nJET Fax Number: 8 1 1 .690 - /4S/4 City State Zip GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name. Mailing Address: City Day Telephone: Fax Number: Zip Expiration Date: ARCHITECT OF RECORD - All plaits must be wet stamped by Architect of City State Zip Day Telephone: 9 / 3 - ' I 22 • 5 Fax Number: 9'13 - 3 22 - 575S 63 132 Zip ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record Ks 64 ?48 Page 1 of 6 Valuation of Project (contractor's bid price): $ 300, Ono Existing Building Valuation: $ Scope of Work (please provide detailed information): EX 1J'r • i S PAGG lb 'FjE' Irmi THE fJ ltutr S A CvESS itorAti. STO RE. TOWAJhrs SPAe6 W111., xwf2CtapE NEW 'PART t sALT TAProltio4 Fi ISNFS r 'Do a &S • To • teT AOaf t =AJSTALLATtw c 1 AtEva SA2Es � $"vack F1)(N.) '3 ADO new rack sto : ge? o te Yes DIVISION: rovide All Building Areas in Square Footage Below ❑.. No If yes, a separate permit and plan sub • tal will be required. Addition to Existing.. Structure` (4 Will there be PLANNING Single family building footprint •• a of the foundation of all structures, plus any decks ov 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling • vide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide doc • ntation that shows that the principal owner lives in one of the dwellings as 's or her primary residence. Number of Parkin • tails Provided: Standard: Compact: Will there be - t ange in use? Q: Applications\Forms- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh Handicap: ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers xe Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes If "yes , attach list of materials and storage locations on a separate 8 - 1 /2 "x 11 " paper including quantities and Material Sa ety No ata Sheets. SEPTIC SYSTEM ❑ On - site Septic System - For on - site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser /1 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat Z 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFVIATION- 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 2 � . o Scope of Work (please provide detailed information): -xws-r ALL c s f /WV/ 'Vuc t ■o aK . 'i)1 F Fu sRS . 7 Aa1' VAv 'plc. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....( Replacement .... ❑ Fuel Tvpe: Electric 181 Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Q:\ ApplicationsWenns- Applications On Linc\3 -2006 - Permit Application.doc Revised 9 - 2006 bh Page 4 of 6 w RKS PERMIT; �Scepe of Work (please provide detailed information): A l� /' �■ Water District ❑ ...Tukwila ❑ ...Water Avai bility Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certific ❑ ...Total Cut ❑ ...Total Fill ❑ ...Water District #125 Submitted with Application (ma boxes which apply): ❑ ...Civil Plans (Maximum Paper 'ze — 22" x 34") ❑ ...Technical Information Report (St. Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply). ❑ ...Right - - way Use - Nonprofit for less than ' hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ .. Abando . - tic Tank ❑ ...Cap or Remove Utilities ❑ .. Curb ' t ❑ ...Frontage Improvements ❑ .. Pa ent Cut ❑ ... Traffic Control ❑ .. . oped Fire Lin ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water FINANCE INFORMATI Water Meter Refund/Billing: Name: Mailing Address: ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension ..Public Private ❑ ...Water Main Extension Public Private Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 - 2006 Call before you Dig: 1- 800 -424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑ .. Highline ❑ ... ValVue ❑ .. Renton ❑ ... Sewer Availability Provided Septic System: ❑ On -site Septic System — on -site septic system, provide 2 copies of a current septic design approv ❑ .. Geotechnical Repo ❑ .. Maintenance A .. Work in Flood Zone ❑ .. Storm Drainage Fire Line Size at Pro. y Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: ❑ .. Renton ❑ .. Seattle ❑ ...Traffic Impact Analysis ment(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right - -way Use - Profit for less than 72 hours ❑ .. Ri: -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Chammelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ...Deduct Water Meter Size by King County Health Department. .. Day Telephone: Mailing Address: City City State Zip Day Telephone: State Zip Page 3 of 6 ftov PERMIT.APP.LICATION:NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY TH PENALTY OF PERJUR Signature: Print Name:' 1.._x4.4 Mailing Address: cUt ? 7- LP r s w rtitkg 4 Date Application Accepted: lit 1 it DI Date Application Expires: aehtlo Staff Initials: i S bM14 +. 34-trJ_ ffri-)N -o( MO 94 tfol q(o C`f lio' IrnL cf10 S4 Q: \Applications\Forms- Applications On tine\3 -2006 • Permit Application.doc Revised: 9 -2006 EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER ATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Telephone: City Date: (Z Ott GI State Zip Page 6 of 6 Fixtu Type , - Qty °- Type. ° ": " Fixture Type: . ' : Q ' °f Fixture Type Bathtub or combination bath/shower Drinking fountain or ater cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste gri er, commercial R eptor, indirect w Clothes washer, domestic Floor drai 1 Sinks Dental unit, cuspidor Shower, ngle head trap Urinals Dishwasher, domestic, with independent drain Lavat ' Water C et , Building sewer or trailer park sewer water system — per ain (inside building) I Water heate nd/or vent f 1 Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or altera n of drainage or ve piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Regi tion Number: Expiration Date: Valuation of Plumbing Valuation of Gas Piping wo Scope of Work (please provide • 44 c d& &toy A.) Cx /ST ' •.k SEtvtce5. Building Use (per Intl Building Code): 1j3c Occupancy (per Intl Building Code): /28 Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outle . be : installed and the quantity below: Q:\Applications\Forms- Applications On 1.-ine\3 -2006 - Permit Application.doc Revised: 9 -2006 CAVALRY, WATEL ctp$E"f A3 4E4.../ gtGp to cn '4E<-r - rzs Page 5 of 6 RECEIPT NO: R07 -02719 Initials: User ID: )Elvl 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Payee: NATIONAL SERVICES GROUP SET ID: S000000912 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D07 -454 1,705.48 EL07 -770 143.50 M07 -271 94.02 PG07 -334 24.50 TOTAL: 1,967.50 TRANSACTION LIST: Type Method Description Payment Check 333590 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE SET RECEIPT TOTAL: Payment Date: 12/11/2007 Total Payment: 1,967.50 Amount 1,967.50 1,967.50 Account Code Current Pmts 000.345.832.00.0 143.50 000/345.830 1,821.51 000/386.904 2.49 TOTAL: 1,967.50 5919 12/11 9710 TOTAL 1967.50 RECEIPT NO: R08 -01226 User ID: 1165 Payee: HORIZON RETAIL CONSTRUCTION, INC. SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : //www. ci.tukwila. wa. us D07 -454 2,621.99 EL07 -770 574.00 M07 -271 406.06 PG07 -334 118.00 TOTAL: 3,720.05 SET RECEIPT Initials: JEM Payment Date: 04/18/2008 SET ID: 0418 SET NAME: GUESS Total Payment: 3,720.05 TRANSACTION LIST: Type Method Description Amount Payment Check 156585 3,720.05 TOTAL: 3,720.05 ACCOUNT ITEM LIST: Description BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 2,619.98 000.322.101.00.0 574.00 000/322.100 406.06 000/322.100 118.00 000/386.904 2.01 TOTAL: 3,720.05 1326 04/18 9711 TOTAL 3720.05 Project: J e .c-- Type of Ispection: F \.AC\ 1\4.1—\/\. Address: LA (y., -1 G \\ Date Called: Special Instructions: Date Wanted: �7 Q a.m. t� - U t\ p.m. Requester: Phone No: 2(02 — 331 - og(o(0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 DI Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: , Inspector: Date: PERMIT NO. - El $60.00 REINSPECTION FEE REQ Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. J Feceit No.: 'Date: COMMENTS: V,4 v I R44-Gt.rr. »o. /2 - P4SSQd cOr✓tS t.3.14- 6 -11‘. Vily -2 Re4-rrt t44/r.ess to iZI - rtis5ed Sz v-�-eS cull 44( -Ik. Date Called: Special Instructions: Date Wanted: Z /6 a.m. .P.m. Requester: Project: . t,ceSS Type of Inspection: tilo e SAk4- do..a address: till 7 MILL Date Called: Special Instructions: Date Wanted: Z /6 a.m. .P.m. Requester: Phone No• 7 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION � 1v-1 -2.1) PERMIT NO. 6300 Southcenter Blyd., #100, Tukwila, WA 98188 (206)431 -3670 S Approved per applicable codes. Corrections required prior to approval. $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. !Receipt No.: 'Date: COMMENTS: - Aep.•o,,a t V‘4"{ 1 %1.4 d L.. Type of Inspection: Smo vi s A,+ -61. (a►^ Address: � Ca 1 dYl,9t- L -- C r. o Q Xg \!S/\ ► C A \ O% V\n . Special Instructions: Date Wanted: i f , / O a.m. p.m. Requester: Phone No: 26 7-3?)--c,74 Project: &A“./. C.' Type of Inspection: Smo vi s A,+ -61. (a►^ Address: � Ca 1 dYl,9t- L -- Date Called: Special Instructions: Date Wanted: i f , / O a.m. p.m. Requester: Phone No: 26 7-3?)--c,74 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspector: Jho~c — 2 7 t Date: 7 /l /b El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: I. rip pee( A t C- E•nC il-ed 'roe fr /u my" ea- . to n C1a C' o / n re, 1-4 c ; 4 -f .. --I .-1 • Address: Date Called: Special Instructions: Date Wanted: a.m. 1 b (U S p.m. C n.nr. a_V, \V∎°_S�r(. \)\C) • Project: 6 ue 6 Type of Inspection: sYi10 I <2 c1. 4--cinw h Address: Date Called: Special Instructions: Date Wanted: a.m. 1 b (U S p.m. Requester: Phone No: 7r, - 3S\- O INSPECTION RECORD Retain a copy with permit froti- 71 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Inspector: PERMIT NO. El Approved per applicable codes. 171Corrections required prior to approval. Date: It/ l ti $ El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Pro' t l : 2/f Address 4 7 /2M f/ Special Instructions: Type of Inspection Date Called: Date Wanted: — Z 7 oe' _ Requester: Phone No: .— ?- i 4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 '0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: f o4Are..._ PlizmAc ComA6N-6 P$� " EA& !> j . r t Q L e c. 5 4 SPA t- p2 , , ' gr,ia00 (Date: 61 s I El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: i Project?... Projec Type_ of Ins ection: SN1 ove Defer-d \.J Address: t 6 - WI f} t ( Date Called: t Special Instructions: - J — Date Wanted: ate. Requester: Phone No: 2 3 1 ^C)C INSPECTION RECORD Retain a copy with permit N ' CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- J Approved per applicable codes. Corrections required prior to approval. COMMENTS: V10— \,e e 1, ' t\ ■Y \\(1.&(( \-1_1% 'Inspector: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspecjion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: 0107 Date• �� bra COMMENTS: A Type of Inspection: • f fit, l'I � RS ;. 5.c lt 5 lit • ° l' r. � r � )2.-e4- vl 5f.rk Ito -.-, n fL T"., r .,t.• Q / /&i .Q,.-\ D((- Date Wanted: 4/or pi Requester: Phone No .26Z 33/ o9tic-. Project: Type of Inspection: • f fit, l'I � !mil i-e- Address: yG 7 /2-7,41 Date Called: Special Instructions: Date Wanted: 4/or pi Requester: Phone No .26Z 33/ o9tic-. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION NO. PERM T NO. (206)431 - 3670 Approved per applicable codes. Corrections required prior to approval. / J lnspecto r: El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Date: ? _ e S 'Receipt No.: 'Date: ti Project: Type of Inspection: ^ Address:,, 7 � / / ! Date Called: Special Instructions: Date Wanted: '197 a.m. p.m. Requester: Phone No: i INSPECTION RECORD Retain a copy with permit /1107 - 71 INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. COMMENTS: p/ goc J c A ,44 404 e i //t Spice; 4 ,„ 49546/ _ $58. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pa' at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. f R eceipt No.: (Date: Project: etit ss -- 'Fire Alarm: Type of Inspection: r -41 /rnei , far Address: y69 5 Suite #: ( 174 L Contact Person: inn-kg-- Special Instructions: Phone No.: ibi - 3 71 - 01' &6 Needs Shift Inspection: Sprinklers: 'Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Tukwila_ Wa. 98188 206 -575 -4407 Li Approved per applicable codes. COMMENTS: ME c. r_ / i��fi�L Inspector: f .lr f j/z Date: 4/7 s /08 V ? 4 / f5V 2 e) PERMIT NUMBERS ri Corrections required prior to approval. Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 NEUDORFER ENGINEERS INC. 55161' Ave S Seattle. WA 98108 Phone (206) 621 -1810 Fax (206) 343-9820 TEST, ADJUST & BALANCE BALANCE REPORT Guess No. 5089 Westfield Mall (Space No. 1545) Seattle, Washington 2008 -467 Project Completion Date: 06/30/08 Revision Date: vac En • in I NE WILLIAM C. NEUDORFER CERTIFICATION 2465 Exp. 12/31/08 dronic 1500 NE Sandy Boulevard. Suite *1 Portland, OR 97232 Phone (503) 235-8924 Fax (503) 235 -8925 N o� -211 Gro ass Revision Number. PO Box 24327 MPO Banipada, Guam 96921 Phone (671) 637 -7810 Fax (871) 637 -7842 814 4 E. Olympia, WA 98501 Phone (360) 528 -8694 Fax (380) 528 / ' Neudorfer Engineers, Inc. Consulting Envnoors Saattl Portland Olympia Guar Report Title 5516 1 Ave S Seattle, WA 98108 Phone (206) 621 -1810 Fax (206) 343-9820 CERTIFIED TEST: BALANCE REPORT Project: Guess No. 5089 Westfield Mall (Space No. 1545) Seattle, Washington NEI Job#: 2008 -467 Engineer: M.E.P. & F.P. Contractor: TI Northwest TAB Firm: Neudorfer Engineers Inc Test Engineer: Doug Neuman 1500 NE Sandy Boulevard, Suite #1 Portland, OR 97232 Phone (503) 235-8924 Fax (503) 235 -8925 WILLIAM C. NEUDORFER CERTIFICATION 2465 Exp. 12/31/08 PO Box 24327 MPO Barrigada, Guam 96921 Phone (671) 637 -7810 Fax (671) 637 -7842 614 4 Ave. E. Olympia, WA 98501 Phone (360) 528 -8694 Fax (360) 528 -8695 Neudorfer Engineers, Inc. Consulting Engtnoors Savtlo Portland Olympia Guam CERTIFICATION Guess No. 5089 The data presented in this report is a record of system measurements and final adjustments that have been obtained in accordance with the current edition of the NEBB Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems. Any variances from design quantities, which exceed NEBB tolerances, are noted in the Test - Adjust - Balance Report Project Summary. Significant / Noteworthy Remarks are noted on the General Remarks and General Field Notes pages. Other remarks are noted on individual test sheets. Noted deficiencies are not the TAB firms responsibility to repair. Prior to issuance of this report, Deficiency Reports are forwarded to our contracted agent. Warranty is limited to one year from date of this report. Within that time, any discrepancies, ambiguities, or omissions found in this report will be retested, adjusted, or balanced as needed. A written notification will be required. Submitted and Certified by: NEBB TAB Firm: Certification No: Expiration Date: Certification Date: (Date completed) Neudorfer Engineers Inc 2465 December 31, 2008 June 30, 2008 Signed and Sealed by: NEBB Supervisor. William C. Neudorfer WILUAM C. NEUDORFER CERTIFICATION 2465 Exp. 12/31/08 Neudorfer Engineers, Inc. Consulting Engineers Soattb Portland Olympia Guam Warranty Project: Guess No. 5089 Warranty of Services: Neudorfer Engineers warranties the TAB work for one year from the date of this report Neudorfer Engineers reserves the right to correct errors or omissions in the collection of data. The Warranty covers Comfort Balancing, Off- Season Testing, and Balancing Issues. Comfort Balancing: Neudorfer Engineers warranty covers comfort balancing for occupants for a maximum of two trips. Off- Season Testing: Typical balance report covers testing and balancing of all scheduled equipment, regardless of the outside air temperature. An Off - Season test will generally cover temperature measurements and occupant comfort issues. Balancing issues: Any balancing issues or concerns that arise, Neudorfer Engineers will return to the site any time during the warranty period. Systems will be rechecked and verified that tested items adhere with the reported test data, AT NO CHARGE. Warranty Procedures: For all warranty items (Comfort Balancing, Off-Season Testing, and Balancing Issues), Neudorfer Engineers requires written request. The written request should be specific on the areas of concern, such rooms, or equipment, and the type of issue the occupants are having. Once written notification is received Neudorfer Engineers will schedule a Technician. It is recommended that and Owner or NE Representative be on site at that time. Voided Warranty and Additional Charges: If a complaint issue is due to a mechanical equipment failure, control or maintenance related, the return trip maybe subject to a service charge, not covered under warranty. Neudorfer Engineers reserves the right to resolve any TAB issue. If a third party or competing Test & Balance/ Commissioning firm test or adjust any equipment, all project warranty is voided. (This is typical standard for the Mechanical industry, as Manufacture, Mechanical and Control Contractor voids all warranty when a competing firm test or manipulates their systems.) Any return trip to the job site are subject to a service charge and a purchase order will be required before returning to the job site. Document Archiving An electric file of all test documents will be kept on file until the end of the Warranty period. During that time and electronic copy of the test data will be provided a no charge. Any additional hard / bound copies requested will be subject to a fee. Neudorfer Engineers, Inc. Co nsutTng Engineers Soanb Portland Olympia Guam Terms and Abbreviations Project: Guess No. 5089 AC or ACU Air Conditioner or Air Conditioning Unit Act. Actual ACCU Air Cooled Condensing Unit Address Equipment designation number given on the Control Program AH or AHU Air Handler or Air Handling Unit Amps Amperage AP Access Point APP. Application Arr Arrangement AVG Average BHP Brake Horsepower BTU British Thermal Units BTUH British Thermal Units per Hour CAV Constant Air Volume CBV Calbirated Balancing Valve (Circuit Setter) CC Cooling Coil CD Ceiling Diffuser CFLA Correct Full Load Amperage CFM Cubic Feet per Minute CH Chiller CHWS Chilled Water Supply CHWR Chilled Water Return Coeff. Coefficient CP Circulating Pump CR Ceiling Register CRAC Computer Room Air Conditioner CRU Computer Room Unit CT Cooling Tower CU Condenser Unit CUH Cabinet Unit Heater CWS Condenser Water Supply CWR Condenser Water Return DAT Discharge Air Temperature DB Dyr Bulb DD Direct Drive DDC Direct Digital Controls: EMS Control System for the HVAC Delta Difference, net decrease or increase Des. Design Dia. Diameter Disch. Discharge DNL Data Not Listed EA Exhaust Air EAT Entering Air Temperature Economizer Controls and components that allow an air handler to logically utilize outdoor air for cooling as opposed to the use of mechanical cooling. EDC Electric Duct Coil EDH Electric Duct Heater EF Exhaust Fan EG Exhaust Grille EMCS Energy Management Control System ERU Energy Recovery Unit E.S.P. External Static Pressure Evap. Evaporator EWT Entering Water Temperature FCU Fan Coil Unit FD Fire Damper FH Fume Hood FLA Full Load Amperage: Maximum amperage a motor can draw. Flow Hood Instrument that captures air and converts the reading to CFM. FPB Fan Powered Box FPM Feet per Minute FR Field Report FT Foot, Feet FTU Fan Terminal Unit GPM Gallons per Minute HC Heating Coil HD Pressure Difference across the entering and leaving side of a pump. Heater O.L_ Thermal overload protection for motors located at the motor starter (starter heaters) HEPA High Efficiency Particulate Arrestance HOA Hand / Off / Auto Switch HP Horsepower Neudorfer Engineers, Inc. Consulting Enginoors Soattla Portland Olympia Guam Terms and Abbreviations Project: Guess No. 5089 HRC Heat Recovery Coil HUH Hydronic Unit Heater HVAC Heating Ventilation and Air Conditioning HWS Heating Water Supply HWR Heating Water Return HX Heat Exchanger HZ Hertz, cycle per second I.D. Inside Diameter in. inches in.w.g. inches of water gauge Kfactor Correction factor to the free area need to calculate CFM. KW IGlowatts LAT Leaving Air Temperature LWG Low Wall Grille LWR Low Wall Register LWT Leaving Water Temperature MAU Make-up Air Hangling Unit MBH 1,000 BTUH MAX. Maximum Flow Requirements for DDC MBH Mega BTUs per hour (1MBH= 1,000BTUH) MIN Minimum Flow Requirements for DDC NIA Not Available NIS Not Shown or Specified OA Outside Air OBD Opposed Blade Damper O.D. Outside Diameter PD Pressure Drop. PH Phase PHC Preheat Coil Prim. Primary PSI Pounds per Square Inch RA Return Air RAT Return Air Temperature RF Return Fan RH Relative Humidity RHC Reheat Coil RPM Revolutions per Minute RTU Roof Top Unit RVA Rotating Vane Anemometer -reads air velocity in feet per minute SA Supply Air SAT Supply Air Temerature S.F. Service Factor Schedule Design data obtained from the (sched) mechanical prints' schedule of equipment. SCR Silcon Controlled Rectifier Speed Controller SF Supply Fan SFD Smoke/Fire Damper SP Static Pressure Spec(s) Specifications sq.ft. square feet Submittals Submitted data on equipment (subs) capabilities. Suct. Suction SWG Sidewall Grille SWR Sidewall Register TAB Test; Adjust; and Balance Tach Tachometer Tech Technician TSP Total Static Pressure: Difference between the entering and leaving static pressure of a fan. TP Traverse or Test Point UH Unit Heater VAV Variable Air Volume; box that contains a motorized damper that modulates airflow. VD Volume Damper VFD Variable Frequency Drive Velgrid Instrument that reads used to read velocity in feet per minute. VP Velocity Pressure VVT Variable Volume Terminal WC Water Column W.G. Water Gauge WB Wet Bulb Motor Data AHU. ACIK / Supply Fan Motor Manufacturer Existing unit Motor Frame Existing unit Motor HP Existing unit Motor RPM Existing unit Motor Rated Volts Existing unit Motor Phase Existing unit Motor Hertz Existing unit Motor FL Amps Existing unit Motor Service Factor Existing unit Brake Horsepower Existing unit Motor Efficiency Existing unit Motor Power Factor Existing unit Sheave Data AHU-LACIK / Supply Fan Motor Sheave MFG Existing unit Motor Sheave Model Existing unit Motor Sheave Diam. Existing unit Motor Sheave Bore Existing unit Fan Sheave MFG Existing unit Fan Sheave Model Existing unit Fan Sheave Diam. Existing unit Fan Sheave Bore Existing unit Number of Belts Existing unit Belt Size Existing unit Sheave Center Line Existing unit Motor to Extend Existing unit Motor to Retract Existing unit Test Pressures Pre - Filter Inlet SP Existing unit Pre -Filter Outlet SP Existing unit Final Filter Inlet SP Existing unit Final Filter Outlet SP Existing unit Pre Heat Coil Inlet SP Existing unit Pre Heat Coil Outlet SP Existing unit Cig Coil Inlet SP Existing unit Cig Coil Outlet SP Existing unit Htg Coil Inlet SP Existing unit Htg Coll Outlet SP Existing unit Fan Suction SP Existing unit Fan Discharge SP Existing unit Design Total SP Existing unit Actual Total SP Existing unit Design External SP Existing unit Actual External SP Existing unit OA Damper Pos Existing unit RA Damper Pos Existing unit Unit Data Unit Manufacturer Existing unit Unit Model Number Existing unit Unit Serial Number Existing unit Unit Discharge Existing unit Starter Data AHU -LACIK / Supply Fan Starter Manufacturer Existing unit Starter Model No. Existing unit Starter Size Existing unit Installed Thermal Existing unit Rating (Amps) Existing unit Required Thermals Existing unit Required Amps Existing unit Amps Test Data Total Design Flow Existing unit Total Actual Flow Existing unit OA Design Flow Existing unit OA Actual Flow Existing unit RA Design Flow Existing unit RA Actual Flow Existing unit EA Design Flow Existing unit EA Actual Flow Existing unit AHU -LACIK / Supply Fan Fan RPM Design Existing unit Fan RPM Actual Existing unit Motor RPM Actual Existing unit VFD Setting Existing unit AHU SP Setpoint Existing unit Motor Volts T1 -T2 Existing unit Motor Volts T2 -T3 Existing unit Motor Volts T1 -T3 Existing unit Motor Amps T1 Existing unit Motor Amps T2 Existing unit Motor Amps T3 Existing unit tvt Ne udorfer Engineers, Inc. Consulting Engineers Seattle Portland Olympia Guam Air Handling Unit Report PROJECT: Guess Jeans (Westfield Mall) LOCATION: Seattle, WA PROJECT #: 2008 -406 SYSTEM/UNIT: AHU -LAC1K AREA: Existing area (Rooftop) NeudoderEngineers, Inc. DATE: 6/26/2008 CONTACT: Doug Heuman Tested By: Doug Neuman Test Date: June 26, 2008 System I Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Reading Prelim Reading Final Reading Final % Remarks Outlet -02 Store area west side Rotating Vane LD 0.67 0.44 375 250 310 275 110 Outlet-03 Store area west side Rotating Vane LD 48x2 0.67 375 250 240 245 98 Outlet -04 Store area west side Rotating Vane LD 48x2 0.67 445 300 305 290 97 Outlet -05 Store area west side Rotating Vane LD 48x2 0.67 375 250 280 270 108 Outlet -06 Store area west side Rotating Vane U) 48x2 0.67 375 250 175 230 92 Outlet - 07 Store area west front Rotating Vane LD 48x2 0.67 150 100 200 105 105 Outlet -08 Store area center front Rotating Vane LD 48x2 0.67 150 100 150 110 110 Outlet -09 Store area east front Rotating Vane LD 48x2 0.67 150 100 250 100 100 Outlet -10 Store area east front Rotating Vane U) 48x2 0.67 375 250 310 225 90 Outlet -11 Store area east side Rotating Vane U) 48x2 0.67 375 250 200 225 90 Outlet -12 Store area east side Rotating Vane LD 48x2 0.67 445 300 280 305 102 Outlet -13 Store area east side Rotating Vane LD 48x2 0.67 375 250 225 230 92 Outlet -14 Store area east side Rotating Vane LD 48x2 0.67 375 250 310 275 110 Outlet -15 Store area east rear Flowhood CD 24x24 1.0 100 75 110 110 Totals : - - - - - 3,000 3,310 2,995 100 % - r � Neurf , Engineers, c. Consultin Engi er Seattle Portland O In Guam Air Handling Unit Report PROJECT: Guess Jeans (Westfield Mall) LOCATION: Seattle, WA PROJECT #: 2008 -406 SYSTEM/UNIT: AHU -LACIK (Cont.) AREA: Existing area (Rooftop) * Notes SYSTEM/UNIT: AHU -LACI K / VAV -01 AREA: Srore area (center rear) Unit Data Manufacturer VAV Address Application # Box Inlet Size Fan: Variable/Constant Trane None VSCF -16 16 Variable AHU-LACI K / VAV -01 Supply Outlet Summary * Notes I Neudorfer Engineers, /nc. DATE: 6/26/2008 CONTACT: Doug Neuman Tested By: Doug Heuman Test Date: June 26, 2008 Tested By: Doug Heuman Test Date: June 20, 2008 Air Test Data VAV Fan Design Flow 3000 CFM VAV Fan Actual Flow 2995 CFM Clg Max Des. Primary Flow 3000 CFM Clg Min Des. Primary Flow 2000 CFM Clg Max Act. Primary Flow 2995 CFM Clg Min Act Primary Flow 1955 CFM Htg Max Des. Primary Flow 2000 CFM Htg Min Des. Primary Flow 2000 CFM Htg Max Act. Primary Flow 1955 CFM Htg Min Act Primary Flow 1955 CFM I System / Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Reading Prelim Reading Final Reading Final % Remarks Outlet -01 Srore area (center rear) Rotating Vane LD 48x2 0.67 445 300 145 305 102 Outlet -02 Stock room Flowhood CD 24x24 1.0 550 390 540 98 Outlet -04 Dressing room Flowhood CD 14x14 1.0 100 95 110 110 Totals : - - - - - 950 630 955 101 % - t I Neudorfer Engineers, Inc. - Consulting Engineers Seattle Portland O+ympia Guam Air Handling Unit Report PROJECT: Guess Jeans (Westfield Mall) LOCATION: Seattle, WA PROJECT #: 2008 -406 SYSTEM/UNIT: AHU -LAC1 K / VAV -02 AREA: Store area (center rear) Unit Data Manufacturer VAV Address Application N Box Inlet Size Fan: Variable/Constant Trane None VSCF -10 10 Variable AHU - LAC1K / VAV - 02 Supply Outlet Summa DATE: 6/26/2008 CONTACT: Doug Heuman Tested By: Doug Neuman Test Date: June 26, 2008 Air Test Data VAV Fan Design Flow 1000 CFM VAV Fan Actual Flow 955 CFM Clg Max Des. Primary Flow 1000 CFM CIg Min Des. Primary Flow 500 CFM Clg Max Act Primary Flow 955 CFM CIg Min Act. Primary Flow 455 CFM Htg Max Des. Primary Flow 500 CFM Htg Min Des. Primary Flow 500 CFM Htg Max Act. Primary Flow 460 CFM Htg Min Act Primary Flow 465 CFM * Notes Neudotfer Engineers, Inc. Motor Data Rated Airflow 100 CFM Motor Manufacturer Fasco Motor Frame U735B1 Motor HP Not Listed HP Motor RPM 1550 RPM Motor Rated Volts 120 Volts Motor Phase 1 Motor Hertz 60 Hz Motor Full Load Amps 1.20 Amps Motor Service Factor 1.35 Sheave Data Motor Sheave MFG Direct Drive Motor Sheave Model Direct Drive Motor Sheave Diam. Direct Drive OD Motor Sheave Bore Direct Drive in. Fart Sheave MFG Direct Drive Fan Sheave Model Direct Drive Fan Sheave Diam. Direct Drive OD Fart Sheave Bore Direct Drive in. Number of Belts Direct Drive Belt Sae Direct Drive Sheave Center Line Direct Drive in. Motor to Extend Direct Drive in. Motor to Retract Direct Drive in. Test Pressures Fan Suction SP -0.05 In. wc Fan Discharge SP 0.01 in. wc Actual Total SP 0.06 in. wc System / Unit Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Cook 140 DCW1995 Size LxW / D Test Data Total Design Flow Total Actual Flow Fan RPM Design Fan RPM Actual Motor RPM Actual Motor Volts T1 -T2 Motor Amps T1 100 CFM 90 CFM 1551 RPM 1485 RPM 1485 RPM 120 Volts 1.11 Amps System / Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Reading Prelim Reading Final Reading Final % Remarks Inlet -1 Bathroom Flowhood CD 12x12 1.0 50 50 50 100 Totals : - - - - - - - - 100 % - Neudorfer Engineers, Inc. „ • Consulting Engineers Seattle Portland Olympia Guam Fan Unit Report PROJECT: Guess Jeans (Westfield Mall) LOCATION: Seattle, WA PROJECT #: 2008 -406 SYSTEM/UNIT: EF-1 AREA: Bathroom EF-1 Exhaust Inlet Summary DATE: 6/26/2008 CONTACT: Doug Heuman Tested By: Doug Heuman Test Date: June 26, 2008 * Notes Neudon'er Engineers, Inc Unit Data Fan Manufacturer TRANE Fan Model Number VSEF16000KODDO4AD21 Fan Serial Number RO8D61400 Starter Data Starter Manufacturer Cutler- Hammer Starter Model No. 3421aqb Starter Size 3-L Rating (Amps) 5.20 Amps Required Amps 15.50 Amps Test Data Total Design Flow 3000 CFM Total Actual Flow 2995 CFM Fan RPM Design 1035 RPM Fan RPM Actual 977 RPM Motor RPM Actual 977 RPM Motor Volts T1 -T2 281 Volts Motor Amps T1 4.10 Amps Neudorfer Engineers, Inc. Consulting Engineers Soattlo Portland Olympia Guam Fan Unit Report PROJECT: Guess Jeans (Westfield Mall) LOCATION: Seattle, WA PROJECT #: 2008-406 SYSTEM/UNIT: VAV - 1.01 AREA: Srore area (center rear) * Notes DATE: 6/26/2008 CONTACT: Doug Neuman Tested By: Doug Heuman Test Date: June 26, 2008 Motor Data Rated Airflow 3000 CFM Motor Manufacturer Not accessible Motor Frame Not accessible Motor HP 1 HP Motor RPM 1030 RPM Motor Rated Volts 277 Volts Motor Phase 1 Motor Hertz 60 Hz Motor Full Load Amps 4.70 Amps Motor Service Factor 1.35 Sheave Data Motor Sheave MFG Motor Sheave Model Motor Sheave Diam. Motor Sheave Bore Fan Sheave MFG Fan Sheave Model Fan Sheave Diam. Fan Sheave Bore Number of Belts Belt Size Sheave Center Line Motor to Extend Motor to Retract Direct Drive Direct Drive Direct Drive OD Direct Drive in. Direct Drive Direct Drive Direct Drive OD Direct Drive in. Direct Drive Direct Drive Direct Drive in. Direct Drive in. Direct Drive in. Test Pressures Fan Suction SP Fan Discharge SP Actual Total SP -0.67 in. wc 0.21 in. wc 0.88 in. wc IVAV -1 -01 24 -Jun-08 Unit has 1- Glassfoss fiberglass 20"x20"x1" filter Neudorfer Engineers, Inc. Unit Data Fan Manufacturer TRANE Fan Model Number VSCF1000QKODDO1AD21 Fan Serial Number RO8D61401 Starter Data Starter Manufacturer Cutler- Hammer Starter Model No. 3421aqb Starter Size 3-L Rating (Amps) 2.00 Amps Required Amps 15 Amps Test Data Total Design Flow 1000 CFM Total Actual Flow 995 CFM Fan RPM Design 1035 RPM Fan RPM Actual 735 RPM Motor RPM Actual 735 RPM Motor Volts T1 -T2 275 Volts Motor Amps T1 1.11 Amps Neudorfer Engineers, Inc. ,, Consulting Engineers Soattlo Portland Olympia Guam Fan Unit Report PROJECT: Guess Jeans (Westfield Mall) LOCATION: Seattle, WA PROJECT #: 2008 -406 SYSTEMIUNIT: VAV -2 -02 AREA: Stock room * Notes DATE: 6/26/2008 CONTACT: Doug Heuman Tested By: Doug Heuman Test Date: June 26, 2008 Motor Data Rated Airflow Motor Manufacturer Motor Frame Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor Full Load Amps Motor Service Factor 1000 CFM Not accessible Not accessible 1 HP 1035 RPM 277 Volts 1 60 Hz 1.60 Amps 1.35 Sheave Data Motor Sheave MFG Motor Sheave Model Motor Sheave Diam. Motor Sheave Bore Fan Sheave MFG Fan Sheave Model Fart Sheave Diam. Fan Sheave Bore Number of Belts Belt Size Sheave Center Line Motor to Extend Motor to Retract Direct Drive Direct Drive Direct Drive OD Direct Drive in. Direct Drive Direct Drive Direct Drive OD Direct Drive in. Direct Drive Direct Drive Direct Drive in. Direct Drive in. Direct Drive in. Test Pressures Fan Suction SP Fan Discharge SP -0.05 in. wc 0.02 in. wc L' 2.02 24- Jun-08 Unit has 1- Glassfoss fiberglass 16"x20"x1" filter Neudon'erEngineers, Inc. 0 v. •••■•••••••• ••••111•11. • a fr61 rm. V.341 IDE 747.7- sme1.1. • 0 ■ e wommi=iimmwric:Rin v ;.e 2 •••••••• •••••■• •■•••■•00/01,04•0111 0011.1111.0•110 MIIM/4.1171•1111.10•01.1 Fl 1I i 0 I I i101 SM. OHMS WA 'MAW MINIPMMIN OW ON WPM J3S C119 SSaflO g I h i li 1 ti ii 1 lk; 1 !I I 11 4' =g .1 I. Ag gd g, i ii 1 „. IN 1 II i 111 I 4 1 II i d v i 4 . 11 ii II li I ' I li I 0 dig oil; . pi r il ii. 1 l ; eli 1 a il I 1 ii -1 4 f Iv 1 . 1 0; p.b ! I I 1 wij ce gi I i i ! 0 i i g. 'II il hi g,, Rh lig 1 I II illi 4 4 7 i 1 11 t I Ili 1 1 1 ) 1 i 1 1 Lli ! 1 in IN 11 ile il V 3 tan h la i 1, il I ig Igi . 0 0 e_E 9 CI 0 ee e o 0 - ii , , - P he! il i fill WI i 1 10 I' fig til II liPi PA i Ili " 0111 p g .4 : III Hing 1 p I 0 . . 4 11 1 , Oii piiimi yii ' 1 ii imq !Oil . 2 ' h Z ik a alk 14 t. i I _if .-; ; Ii im;: = 4 od 10.ii II I e I d 01 it HI II . , g. milmictrot come am NVAC SPIC7RCAflONII AND RITA S 9 a win nflMr M2 Immt am= I is wain . w, N. pm apse s i CUM — WILL I ma°t wA MMi �a f : - nlel; m i rej41 CINonan wl wow am...! l r 0 a w ® • Ilan w. ! a Mt yr.,. w! \, !a R Ma `• I MINI ' a II w mr•MMY MC My. , IN MILNE cps, maw mew us p.Nev M !CNN n a • POINT OF USE "AM NG1EA PIPING. DUCI.OMC MO MOMENT ld 1c•II DETAILS 101 • • PLUMBING FIXTURE SCHEDULE CESORPTC I MNOPACIIAIOI / CATALOG Iq , !` • Rkk �z� Rd g I ;' yt ; R � g i V as war T NW MIL Mr IN r r �e . mil ~ s lAmt O. PM .At Vr � � SIl1YL 121 PI AL MG SCHEDULES PUJMBING RISERS .1.5. TRANI [MC tQRTPY[AT FACLAG • wawa PA rA.t Mathew ILL DAM fl EO11111IR 180 Mao Millen. O{r se man twessTMa MUMS CM IM MMS.O> CM a MAO am w Haim >fQenR' M[fMIIIII II. mcallet Tom= to M. 1S�:Jt MAIM MIMIC M1 Mw MOW ImmtwaVraccelc art to =Arm. cm mem me M a M AIMMOw1.1 ..MaMM.MM �, an., mmtalt MT Comm. mommodriml LC la 31cAL MINIM atm. mem at mow. cm imam Arlimst worm A>m IM COMM n IIIII w MMMS maw= IMtwwn emwMneM\MUMn mn •.e-- 1.,nM\M u PAtREAOAaS. 111..MIMAIMS cm tame. mmer• arm micrelmit NIL. mareuratrt NMI* MTZ MM I W ri from ammatri mum VAV TERMINAL UNIT WITH ELECTRIC REHEAT SCHEDULE PIA _,IPIRIAPICZINI...gt191111H.111r11 _• - 'i. M\M • M MUM ..man M. WWII a[ MM L Most MM MOM MM. MINOR . : C0 1�. 1.�R"'lo .)1.'�� WEIPf � N a!'� a MMM I M P. 41 1101011 .Ma. a I wow � t GRILLE REGISTER, AND DIFFUSER SCHEDULE IIIMIIIIMMMIIILZ MIMt OM • MI Min .. C. MIMIC SIM P WAN IAN lw.M,L.IIl..MN=SL'rAIM- s.'l∎MMI yMMi,1MISMMI a•V 1l .e M � e mmo... + YI 1 ,M � Me••MMI•wl =11o;.:=Iw\`f i'irti�.iM�t1'R IMF. .M1 w WC a s Mum M0. Mar MI MaCti COMO CAM MOIMIV NW W%P : . 1:11==1 wll �t -- HVAC SCHEDULES 2 01 milmictrot come am NVAC SPIC7RCAflONII AND RITA S 9 a win nflMr M2 Jennifer Marshall - Guess Southcenter Tukwila WA Change of contact Tel 410 544 1700 Westfield South Center Mall Guess # Guess 633 Southcenter Mall Space 1545 Tukwila WA 98188 D07 -454 EL07 - 770 M07 - 271 PG07 - 334 Brett Delmez Tel 314 - 721 -1340 PM Mobile # Arch : Epoch GC : Pdg Re: Report To: Retail Dev Team : 1) Change of contact request (To : Lauren Chase ) 2) Please forward the latest comments (12 21 07 ) From: "Lauren Chase" <lauren _chase @nationalpermits.com> To: "Jennifer Marshall" <jarshall @ci.tukwila.wa.us> Date: 01/09/2008 1:16 PM Subject: Guess Southcenter Tukwila WA Change of contact CC: "'Lauren Chase.NSG (Lauren Chase.NSG)"' <lauren chase@nationalpermits.com> From: Lauren Chase, National Account Manager National Services Group 626 C Admiral Drive, Pmb Suite 120 Annapolis, MD 21401 Fax 410 544 1692 Lauren : Cell 443 994 8531 <mailto:lauren chase@a,nationalpermits.com> http: / /www.nationalpermits.com If you have any questions, please contact the writer at Tel 410 544 1700 Page 1 of 2 >' file: / /C:\ Documents %20and %o20Settings \iennifer -m\ Local %20Settines \Temn\XPGrnWis... 01/09/200R Thank You Lauren Chase, National Account Manager National Services Group, Inc Yage 2 ot 2 NSG INC 2006 All Rights Reserved . This Document and the associated documentation are the property of NSG INC and may be used under license as authorized by NSG INC. Please Note : All reporting data / status / estimates / accuracy are time sensitive and may / will be revised / updated ,please contact the NSG and or the goveming jurisdiction if you have any questions . Final Approval is directly contingent upon acceptance and approval by the governing jurisdictional authorities of the required Owner / Designer / Contractor documentation.Approval Notification : The Client and /or their General Contractors , Subcontractor(s), Vendor(s) must submit their required License(s) , Insurance(s) , Bond(s) , Fee(s),etc as required to the governing jurisdictions This email and any attachments are confidential and intended solely for the use of the named addressee. If you are not the named addressee you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited. E -mail transmission cannot be guaranteed to be secure or error -free as information could be intercepted. corrupted, lost, destroyed, arrive late or incomplete, or contain viruses. The sender therefore does not accept liability for any errors or omissions in the contents of this message, which arise as a result of e-mail transmission. If verification is required please request a hard -copy version file: / /C:\ Documents %20and %20S ettings \i ennifer- m\Loca1 %20Settings \Temp\XPGrp Wis... 01/09/2008 ACTIVITY NUMBER: M07 -271 DATE: 12 -12 -07 PROJECT NAME: GUESS SITE ADDRESS: 467 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: I214 _91 B it ► ing P ivision Public Works Complete Comments: Please Route TUES/THURS ROUTING: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 HERMIT COORD COPS' PLAN REVIEW /ROUTING SLIP 5(1 A1N(i 11- Fire Prevention [Sk Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Permit Coordinator ❑ DUE DATE: 12-13-07 Not Applicable n No further Review Required DATE: DUE DATE: 01-10-08 Not Approved (attach comments) n DATE: Planning Division n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License HORIZRC072N5 Licensee Name HORIZON RETAIL CONST INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601483044 Ind. Ins. Account Id Business Type CORPORATION Address 1 1458 HORIZON BLVD Address 2 City RACINE County OUT OF STATE State WI Zip 53406 Phone 2626386000 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/25/1993 Expiration Date 4/15/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HENDERSEN, JON E 01/01/1980 GUSTIN, ROBERT L 01/01/1980 HENDERSON, JON E 01/01/1980 JAWORT, DAN AGENT 01/01/1980 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date a %abv a va �r https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= HORIZRC072N5 04/18/2008 10 NOTE: 1. ALL OF THE MECHANICAL WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THEIR WORK BEFORE BIDDING. NOTIFY THE OWNER OF ANY DISCREPANCIES. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER'S REPRESENTATIVE SHALL BE PART OF THIS CONTRACT. 2. THE SUBMISSION OF PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS CLAIMS FOR EXTRA WORK MADE NECESSARY BY THEIR FAILURE TO VISIT THE SITE. 3. GUARANTEE ALL EQUIPMENT AND MATERIAL INSTALLED UNDER THIS CONTRACT TO BE FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE AND REPAIR OR REPLACE WITHOUT COST TO THE OWNER ANY EQUIPMENT WHICH IS DEFECTIVE, OR IMPROPERLY INSTALLED. IN ADDITION, ASSUME FULL RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING AND ITS CONTENTS OR OTHER EQUIPMENT CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF EQUIPMENT OR MATERIALS INSTALLED UNDER THIS PORTION OF THE WORK. 4. ALL WORK SHALL BE COMPLETED AND INSTALLED ACCORDING TO STATE AND OR LOCAL CODES, AND ALL LANDLORD CRITERIA. 5. PAY FOR ALL REQUIRED PERMITS AND INSPECTIONS AND PROVIDE A CERTIFICATE OF INSPECTION. 6. REVIEW ALL LANDLORD REQUIREMENTS AND INSTALL ALL MATERIALS AND EQUIPMENT AS DIRECTED BY THE LANDLORD'S REPRESENTATIVE AND AS REQUIRED BY THE LEASE DOCUMENTS. VERIFY THE REQUIREMENTS BEFORE SUBMITTING A BID. 7. VERIFY THE SIZE, LOCATION AND CONDITION OF THE EXISTING DUCTWORK, EQUIPMENT AND CONTROLS THAT ARE TO REMAIN. NOTIFY THE OWNER OF ANY DISCREPANCIES. REPLACE EXISTING COMPONENTS IF INADEQUATE FOR THE NEW REQUIREMENTS OR INOPERABLE, COORDINATE REPLACEMENT COMPONENT SPECIFICATIONS WITH THE LANDLORD'S FIELD REPRESENTATIVE. 8. FIVE (5) COPIES OF ALL SHOP OR EQUIPMENT DRAWINGS SHALL BE SUBMITTED TO THE OWNER. THESE DRAWINGS SHALL BE CLEARLY MARKED INDICATING WHICH ITEMS ARE TO BE SUPPLIED AND SHALL STATE CAPACITIES, SIZES, REQUIRED INSPECTION LABELS AND GENERAL DESCRIPTION OF ALL EQUIPMENT AND FIXTURES. 9. ALL AIR INTAKES AND EXHAUSTS NEED TO BE SEPARATED BY A MINIMUM OF 10' --O ". 10. NO COMPONENTS MAY BE ABANDONED IN PLACE WITHOUT PERMISSION FROM THE OWNER. ALL COMPONENTS THAT ARE NOT REUSED MUST BE REMOVED. 11. VERIFY ALL CLEARANCES AROUND NEW AND EXISTING EQUIPMENT. 20 GENERAL NOTES SCALE: 1 /4" = 1' -0" 19 • t • y �€ � f��, � �.1... I,��h. r -� ,� - � - • � K w, a_ _,. ,,. .-� : • , i . � rw; H _.._... .... �� .. _ _.._... _ _._ 0 0 20x20 20x14 20x14 0 EXISTING CONDITIONS WERE TAKEN FROM SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBM!TTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. MECANICAL, FIR SPRINKLER AND PLUMBING - PLAN SCALE: 1 /4" = 1 '-0" ;VAV -2 i 550 41) 0 $ I 0 sl 10 m f_ A. FABRICATE AND INSTALL GALVANIZED SHEET METAL DUCTWORK FOR VELOCITIES LESS THAN 2000 FEET PER MINUTE AND STATIC PRESSURES OF LESS THAN 2" WATER GAUGE IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA'S LOW VELOCITY DUCT CONSTRUCTION MANUAL. ALL ELBOWS AND BRANCHES FROM THE MAIN IN ALL SUPPLY AND RETURN DUCTS SHALL BE PROVIDED WITH TURNING VANES. DUCTWORK SHALL BE CONSTRUCTED, INSTALLED, SEALED AND INSULATED IN ACCORDANCE WITH THE LATEST EDITION OF THE MECHANICAL CODE. FIBERGLASS DUCTBOARD IS NOT ACCEPTABLE. ALL RIGID DUCTWORK SHALL BE SHEET METAL. B. TEST AND ADJUST ALL AIR HANDLING EQUIPMENT TO PROVIDE THE REQUIRED AIR VOLUME MTHIN 10% OF DESIGN CONDITIONS. TEST AND ADJUST ALL AIR DEVICES TO THE CFM SHOWN ON THE DRAWINGS. PROVIDE ALL CHANGES REQUIRED TO OBTAIN CFM QUANTITIES SHOWN ON THE DRAWINGS. TESTING AND BALANCING SHALL BE BY AN INDEPENDENT TEST AND BALANCING AGENCY IN ACCORDANCE WITH THE PROCEDURES OUTLINED IN THE TESTING AND BALANCING MANUAL AS PUBLISHED BY SMACNA, THE OWNER SHALL BE PROVIDED WITH THREE CERTIFIED COPIES OF THE AIR BALANCE REPORT BEFORE FINAL PAYMENT WILL BE MADE. C. FURNISH AND INSTALL ALL MECHANICAL EQUIPMENT AND OR AIR DEVICES AS SCHEDULED ON THE DRAWINGS. BIDS SHALL BE BASED ON THE EQUIPMENT SPECIFIED AND NO SUBSTITUTIONS WILL BE ACCEPTED. D. FURNISH AND INSTALL ALL SYSTEMS OF HVAC CONTROL (TO INCLUDE CONTROL WIRING) TO PROVIDE A COMPLETE SYSTEM. E. FLEX DUCTWORK SHALL NOT EXCEED 5' -0" IN LENGTH. FLEX DUCTWORK ALLOWED ONLY IN ACCESSIBLE AREAS PER CODE. ONLY ONE 90 DEGREE ELBOW ALLOWED N FLEXIBLE DUCTWORK. ELBOWS SHALL BE INSTALLED TO MAINTAIN A 1 - 1/2" DIAMETER ENTERLINE RADUIS. FLEXIBLE DUCT NOT PERMITTED ABOVE GYP. BOARD CEILINGS OR IN INACCESSIBLE AREAS. F. ALL ROOF MOUNTED EQUIPMENT SHALL BE MOUNTED A MINIMUM HEIGHT OF EIGHT INCHES ABOVE THE EXPOSED ROOF MEMBRANE, PER THE LANDLORD'S REQUIREMENTS. PENETRATIONS TO ROOF OR NEW CURBS /FLASHING TO BE DONE BY MALL'S ROOFING CONTRACTOR. ALL EQUIPMENT ON ROOF TO HAVE PHENOLIC SIGN WITH TENANT NAME AND SPACE #. MECHANICAL SPECIFICATIONS SCALE: 1 /4" = 1' -Q" 18 o i? d O 0 0 0 0 0 0 0 0 0 10 11 12 FURNISH AND INSTALL ADA COMPLIANT WATER CLOSET, (WC -1), AMERICAN STANDARD MODEL 2377.100, OPEN FRONT SEAT LESS COVER. LOCATE WATER P CLOSET CENTERLINE 18" FROM WALL, 1.6 GALLON TANK TYPE. LOCATE FLUSH Ap HANDLE ON SIDE CLOSEST TO BATHROOM DOOR. QQ FURNISH AND INSTALL ADA COMPLIANT LAVATORY, (LAV -1), AMERICAN STANDARIT 0356.421, WITH WALL BRACKET, GRID STRAINER, OFFSET P— TRAP. AMERICAN STANDARD #7501-170 CENTERSET LAVATORY FAUCET. FURNISH AND INSTALL 0.5 GAL., INSTANTANEOUS, 750W, 120V ELECTRIC WATER HEATER, (EWH-1), BELOW LAV. WATER HEATER SHALL BE INSINKERATOR MODEL UWL. FURNISH AND INSTALL FLOOR DRAIN, (FD -1), ZURN MODEL Z- 453 —P WITH 7"0 STRAINER & DEEP SEAL TRAP. NOT USED. 3/4" CW LINE, CONNECT TO EXISTING CW LINE, VERIFY LOCATION IN FIELD. 30 "x30" ACCESS PANEL FOR VAV -1, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. PAINT TO MATCH CEILING. FURNISH AND INSTALL NEW CEILING MOUNTED EXHAUST FAN, (EF -1), COOK MODEL GC -140, 100 CFM, 120V. ROUTE 6 "0 EXHAUST DUCT TO LANDLORD PROVIDED MAIN EXHAUST DUCT, VERIFY EXACT LOCATION IN FEILD. CONNECT MEDIUM PRESSURE SUPPLY DUCT TO VAV BOX TO EXISTING LANDLORD MAIN SUPPLY AIR DUCT. VERIFY EXACT LOCATION IN FIELD. CONNECT SANITARY LINE TO EXISTING SANITARY MAIN, VERIFY EXACT LOCATION IN FIELD. CONNECT VENT LINES FROM WC-1, LAV -1 AND FD -1 TO EXISTING VENT STACK, VERIFY EXACT LOCATION IN FIELD SPRINKLER HEAD IN TOILET ROOM. FURNISH AND INSTALL SENSOR WITH AUTO CHANGEOVER FROM HEATING TO COOLING TO CONTROL VAV BOX. SPRINKLER SYSTEM SHALL BE MODIFIED AS REQUIRED TO SERVE THE NEW LAYOUT e 13 SHOWN ON THE DRAWING. NOTIFY THE MALL MANAGER 72 HOURS BEFORE SPRINKLER SHUTDOWN IS REQUIRED AND PAY ALL MALL CHARGES FOR SPRINKLER SHUTDOWN. 14 CONNECT TO THE LANDLORD'S EXISTING SPRINKLER LINE AND TO CONNECTIONS THAT EXIST IN THE SPACE TO ACCOMMODATE THE NEW SPRINKLER LOCATIONS. e 15 FURNISH AND INSTALL GALVANIZED STEEL DUCTWORK, SIZES AS NOTED ON DRAWINGS. DUCTWORK SIZES ARE CLEAR INSIDE DIMENSIONS. ALL NEW DUCTWORK SHALL AHVE 1/2" INTERNAL LINER. KEY NOTES 0 • . -.1", . ,e,• • Ian review v violation of col arty ate. nerravad Field Copy and Tow City of Tuk O BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: ❑ echanical ;Electrical Iumbing el Gas Piping City of Tukwila BUILDING DIVISION WC -1 i ■ I 0 444 " . 1 12 8 "o 0 6J 0 No changes shall be roarim to th^ sC'r r' I of work without prior approval of Tukwila Building Division. NOTE: !Revisions will require a new plan submittal ` and may include additional plan review fees . _. -I 8 0 I. 0 f : . _ • 1 7 MECHANICAL, FIRE SPRINKLER & PLUMBING PLAN CONT. SCALE: 1 /4" = ,u r • s4_� w , s :x • fir 0 11 i 5111111111' \100° ( c 7 S1 10 "0 r D 2 ri ` ? 4 E I I H W I 1 F; Z sa i VAV -2 RECEIVED — _ ELEC. _ Q0 0 N� ., ... ...e ,.y..� � ..... ,.,� ,.. awtl l.6L•CL1 LER,••,,,i I W Z PROJECT TEAM: Architect: Epoch Design Group, Inc. 1155 011vette Exec. Pkwy. Suite 100 St. Louis, MO 63132 TEL 314.721.1340 FAX 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913 322 - 5150 FAX, 913-322-5155 THIS DOCUMENT LS THE PROPERLY OF @OCH DESIGN GROLR, COPYRIGHTED AS DATED, ALL RIGHTS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT IS NOT TRANSFERABLE THE REa 1ENT OF THIS DOCUMENT IS HEREBY ADVISED THAT IT IS RELEASED FOR USE CINDER THE FOLLOWING TERMS AND CONDITIONS: THE DOCUMENT IS TO LIE USED ONLY DI CONJUNCTION WITH TI PROJECT. REUSE OF ANY PORTION OF THE DOCUMENT IN ANY OTHER CIRCUMSTANCE CONSTITUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT I5 FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES NOT CONSTITUTE AS -CULT CONDITIONS. TFE RECIPIENT RETAINS THE OBLIGATION TO VERIFY THE CONDITIONS OF THE SUBJECT PROPERTY AND TO COMPLETELY ODORDPUTE ALL DUAENSIONS, FABRICATION METHODS, RELATID AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO ALL ASPECTS OF THE WORM„ EPOCH DESIGN GROUP hLkRIS NO WARRANTY AS TO THE SUITABILITY OF THE DOCUMENT FOR THE RECPFMS INTENDED USE. THE RECIPIENT SPEOHCA,LY AGREES TO WAVE AND TO INDEMNIFY AND DEFIBID ANY AND ALL CLAMS AGANST EPOCH DESIGN GROUP. ITS CONSULTANTS, ANY OF ITS RELATED ENTITIES, VE NDOks, OR CONTRACTORS, FOR ANY LOSS INCURRED ASA RESULT OF PROPER OR IMPROPER USE OFTMS DOCUMENT, % YTEAS DOCUMRR 7 1 y- THEREWENT ;: .•' °yam{ 7E;D UPON CO ,N I3R TE ^ ONII K HTHR P " ' s . PROJECT TITLE: SHEET TITLE: MECHANICAL FLOOR PLAN DRAWN BY: JCC ISSUE DATE: 11/07/07 -34 C'7 0 0 n N nn C7 L) 6 a U -I No-A Revision Description Date PROJECT NO SHEET NUMBER: 07073 M1 PROJECT TEAM: Architect: Epoch Design Group, Inc 1155 Olivette Exec. Pkwy. Suite 100 St. Louis, MO 63132 TEL 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: This DOCUMENT Is THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED AS DATED, ALL RIGHT S RESERVED. ALITHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT I5 NOT TRANSFERABLE THE REORIENT OF HIS DOCUMENT LS HEREBY ADVISED THAT R IS RELEASED FOR IAE LMDER THE FOLLOWING TERMS AND CONDRION THE DOCUMENT LS TO BE USED ONLY IN CO W UN CRON WITH TF#S PROJECT. REUSE OF ANY PORTION OF THE DONMENT N ANY OTHER CJRWMSTMTCE CONSTRUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT is FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES LO =CONSTTTULE AS-BULT CONDRIONT. THE RECBIENT RETAINS THE OBLJGATION TO V6LEYTHE CONDRIONs OF THE SUBJECT FROFERTY AND TO COMPLETELY cOOR *IMR ATL DIMENSIONS, FABRICATION METHODS, RELATED AND MTEGRATED SYSTEMS, ETC. WITH RESPECT TO ALL ASPECTS OF THE WORK EPOOT DESIGN GROUP MAKES NO WARRANTY AS TO THE SUTABILTI'Y OF THE DOCUMENT FOR THE RECEENT'S ATTENDED USE. TEE RECEENT SPEOHCALLY AGREES TO WANE AND TO INDEMNIFY AND DEFEND ANY AND AU CLAIMS AGAINST EFOGl DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED ENPRIET. Vf340ORS, OR CONTRACTORS, FOR ANY LOss INCURRED AS A RESULT OF PROPER OR IMPROPER USE OF His DOOJMEM. PROJECT TITLE: cir) w No,Q Revision Description Date SHEET TITLE: HVAC SPECIFICATIONS AND DETAILS DRAWN BY: JCC ISSUE DATE: 11/07/07 a D D u 0 W y X t!] W W La- � • 0 0 k l '— RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913 - 322 -5150 FAX= 913 -322-5155 on PROJECT NO.: SHEET NUMBER: 07073 M2 SINK OR LAV, TRANSITION TO BRANCH Al SIZE IN RADIUS ELBOW WATER HEATER CONTROL HOT AQUA MODEL 35 -208 SINGLE PHASE EWH -1 5 GPM COLD WATER 1D FULL D SUPPORT ANGLES AND STIFFENERS TO BE SUPPLIED AND INSTALLED BY M.C. 1 PROVIDE A SUPPORT ANGLE SPANNING TWO OR MORE JOISTS; 3 X 3 X 1/4" SUPPORT ANGLE WHERE JOIST SPACING IS OVER 2' -0" DEPTH OF 15 DEG DUCT BUT NOT MORE THAN 4' - -0 ", PROVIDE 2 X 2 X 1/4" SUPPORT ANGLE WHERE JOIST SPACING IS 2' -0" AND UNDER. WHERE LOAD EXCEEDS 500 POUNDS PER HANGER, SEE STRUCTURAL DRAWINGS FOR DETAILING. ' TO SIZE MAIN BRANCH DUCT ; '' LOCK NUT I .1 LARGE (� J I (� 2 FIELD WELD. , STOP VALVE BRANCH WASHER BOTTOM 3 PROVIDE STIFFENER ANGLE WHERE LOAD BEING HUNG EXCEEDS 250 IBS, (DUAL OUTLET) � " . D 111111 ELBOW VANED 30 DEG D Q / / CHORD OF JOIST 1 . /2 x 1-1/2 STIFFENER x © 3/16 FIN. FLOOR DET IL 1 SUPPORT ANGLE LOCK NUT 1/2 "? BOLT LARGE THIS WASHER NUT I _ _ . . µ � _ HANGER ROD PANEL LOCK NUT LARGE WASHER BOTTOM CHORD .1. OF JOIST LOCK NUT J TURNING VANES POINT w� � _ . ; I I CONTRACTOR) �I',,, BRANCH DUCT FULL DEPTH OF MAIN DUCT TRANSITIONS J'. � , FJ� � _. ;, I 2 .`. fr, ^W- THIS METHOD ALLOWABLE FOR MAX. 150 LB. LOAD WITHIN 6" OF PANEL __ . _.,. _ ��.. HANGER ROD w:: ' NOTES:, . '' *ter . = ' * as :w Y I HANGER ROD ': POINT; BEYOND 6" OF PANEL POINT 50 L.B. MAX. LOAD ALLOWABLE. WHEN MULTIPLE PIPES/DUCTWORK ARE PERPENDICULAR TO JOISTS, HANGERS SHALL BE STAGGERED SO THAT 6" 6" "' LARGE WASHER BOTTOM CHORD OF JOIST ANGLE SECTION NOTE: POINT OF USE WATER HEATER SHALL BE POSITIONED SO AS NOT TO ENCROACH INTO ANY REQUIRED WHEELCHAIR ACCESS CLEARANCES BENEATH THE LAVATORY AND SHALL BE SHEILDED AGAINST HUMAN CONTACT a N ' 1/2"? BOLT LOCK NUT 1 1 SUPPORT 1. DETAIL AIL IS APPLICABLE TO SUPPLY AIR BRANCH DUCT TAKE -OFFS. _ B SECTION BRANCH DUCT SIDE TAP PIPING /DUCTWORK IS NOT SUPPORTED THIS FROM SINGLE JOIST. r DETAIL THIS N.T.S. THIS DETAIL N.T.S. POINT OF USE WATER HEATER DETAIL BRANCH DUCT TAKEOFFS AND TRANSITIONS TYPICAL JOIST HANGER DETAIL FOR PIPING, DUCTWORK, AND EQUIPMENT NO SCALE NO SCALE 1 0 DETAILS A. PROVIDE ALL LABOR AND MATERIAL FOR A COMPLETE PLUMBING SYSTEM AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING BID. " " B. FURNISH AND INSTALL STANDARD WEIGHT CAST IRON SOIL PIPE WITH NO -HUB FITTINGS FOR ALL WASTE AND VENT PIPING ABOVE GRADE AND SERVICE WEIGHT CAST IRON PIPING WITH APPROVED COMPRESSION JOINTS UNDER FLOOR. C. INTERIOR WATER PIPING ABOVE THE FLOOR SHALL BE TYPE L WITH 95 -5 SOLDERED JOINTS. VALVES SHALL BE NIBCO S -590 BALL VALVES OR EQUIVALENT. TEST WATER PIPING TO 125 LBS. FOR AT LEAST TWO HOURS WITH NO LEAKS BEFORE COVERING. INSULATE HOT AND COLD PIPING ABOVE THE FLOOR WITH 1" THICK FIBERGLASS TYPE WRAP AROUND INSULATION WITH ALL SERVICE JACKET. D. ALL PENETRATIONS OF FLOOR SLAB SHALL BE SAW CUT, GROUTED, AND SEALED WATER PROOF. E. CAP ALL UNUSED PLUMBING LINES ASSOCIATED WITH LEASED SPACE AS REQUIRED BY LANDLORD AND LOCAL INSPECTION AUTHORITIES. F. FURNISH AND INSTALL A BACKFLOW PREVENTER PER MALL CRITERIA, IF REQUIRED. G. PVC PIPING NOT PERMITTED. PLUMBING FIXTURE SCHEDULE DESCRIPTION MANUFACTURER / CATALOG NO. WC -1 AMERICAN STANDARD "CADET" 16 1/2" HIGH ELONGATED (BARRIER FREE) 1.6 GPF, PRESSURE ASSISTED TOILET. 42377.100 (BOWL 43109.016, TANK #4098.100, SEAT "LAUREL" 45311.012). D -1 3/4" �� ROOF UNE �. .___...._._........., 3/4" 2" j 2" 2 " FURNISH AND INSTALL TRAP PRIMER FOR FLOOR DRAIN FLOOR LINE 4 „ LAV -1 AMERICAN STANDARD WALL HUNG (BARRIER FREE) LAVATORY #0356.421 WHITE, FAUCET: 7501 -170, 0.5 GPM WITH WRIST BLADE HANDLES AND GRID STRAINER. EWH -1 INSINKERATOR MODEL # UWL, 0.5 GALLON, INSTANTANEOUS, 750W, 120V ELECTRIC WATER HEATER, INSTALLED UNDER SINK. LAV . 3/4" WC 1/2" LAV -1 -1 3 .J FD -1 WC - '' 4 l . - - - - -- EW- -1 1/2" Q .'._ ...........__. _.__ ....... ............ ..W., 1 /2" WATER RISER DIAGRAM FLOOR LINE 3 „ 4" 4" WASTE RISER DIAGRAM 15 PLUMBING RISERS 13 PLUMBING SPECIFICATION 12 PLUMBING SCHEDULES VAV TERMINAL UNIT WITH ELECTRIC REHEAT SCHEDULE TRANE EQUIPMENT PACKAGE EQUIPMENT PACKAGE INCLUDES ALL TRANE HVAC EQUIPMENT AND RELATED ACCESSORIES SUCH AS CURBS, THERMOSTATS, HEATERS, ETC., AS SPECIFIED ON THE PLANS AND SPECIFICATIONS FOR GUESS? INCORPORATED. FOR COMPLETE INFORMATION ON THE EQUIPMENT PACKAGE CONTACT THE TRANE NATIONAL ACCOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS: PATRICK BRONSON PHONE: (626) 435 -1176 — DIRECT LINE TRANE NATIONAL ACCOUNTS TOLL FREE: (866) -1611 17760 ROWLAND ST. CITY OF' INDUSTRY, CA 91748 ASSISTANT: TOM CALLAGHAN PHONE: (626) 435 -1181 — DIRECT LINE MARK SERVICE MANUFACTURER MODEL NOMINAL CFM MAX COOLING CAPACITY _ HEATING CAPACITY ELECTRICAL NOISE CRITERIA NOTES INLET CFM EAT LAT SENSIBLE (MBH) CFM EAT LAT MBH KW MCA MOCP V /PH /HZ DISCHARGE RADIATED S.P MAX MIN VAV-1 LL AHU TRANE VSEF -16 3000 0.75 3000 2000 55 55 2000 55 75 51.22 15 28.4 30.00 480/3/60 20 34 A, B VAV - 2 I LL AHU TRANE VCEF -12 2000 0.75 1000 500 55 55 NA NA NA NA NA 2 15 277/1/60 20 34 A, B NOTES: . A. PROVIDE WITH HANGER BRACKETS AND SUSPEND FROM STRUCTURE WITH ALL THREAD HANGING ROD. ._ B. PROVIDE WITH FACTORY INSTALLED DISCONNECT SWITCH FAX: (626) 913 -2489 EMAIL: PBRONSONOTRANE.COM or TCALLAGHAN @TRANE,COM GRILLE REGISTER AND DIFFUSER SCHEDULE > > PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) ) shari g the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) RECEIVED CITY OF TUKWILA ANY CHANGES OR VARIATIONS TO THE ORIGINAL EQUIPMENT PACKAGE THAT WOULD AFFECT THE HVAC EQUIPMENT PACKAGE SHOULD BE BROUGHT TO THE ATTENTION OF THE ACCOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS. MARK MANUFACTURER MODEL FACE TYPE MOUNTING LOCATION FACE SIZE (IN) MAX (NC) NOTE Si TITUS FL -20 HT SLOT SURFACE 48" 28 B,C NOTE: ORDERING PROCEDURES S2 TITUS 300RL LOUVERED DUCT 12 "x8" 28 A,B,D GENERAL CONTRACTOR OR MECHANICAL CONTRACTOR PURCHASES THE EQUIPMENT PACKAGE DIRECTLY FROM THE TRANE NATIONAL ACCOUNTS S3 TITUS OMNI LOUVERED SURFACE 12 "X12" 24 D A,B,D SALESMAN. PATRICK BRONSON. THE H VAC CONTRACTOR WILL BE RESPONSIBLE FOR FIRST YEAR LABOR WARRANTY, DELIVERY COORDINATION, R1 TITUS 35ORL LOUVERED SURFACE 24 "x2 �— B RECEIVING AND INSTALLATION AS DESCRIBED IN THE SPECIFICATIONS. PARTS WARRANTIES TRANE WARRANTIES ALL PARTS FOR A PERIOD OF ONE (1) YEAR FROM INITIAL STARTUP OR 18 MONTHS FROM DATE OF SHIPMENT, WHICHEVER OCCURS FIRST. CERTAIN EQUIPMENT COMPONENTS HAVE AN EXTENDED WARRANTY LONGER THAN ONE (1) YEAR. TRANE PARTS WARRANTIES BELONG TO THE EQUIPMENT OWNER. NOTES: A. AIR DEVICE RUN —OUT SHALL BE SAME SIZE AS DIFFUSER NECK. B. AIR DEVICE COLOT TO MATCH CEILING COLOR C. PROVIDE WITH FACTORY PLENUM CONNECTION. D. PROVIDE WITH INLET DAMPER. DEC 1 1 2007 PEFilvii i ( IV I tR 20 HVAC SCHEDULES PROJECT TEAM: Architect: Epoch Design Group, Inc 1155 Olivette Exec. Pkwy. Suite 100 St. Louis, MO 63132 TEL 314.721.1340 FAX: 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: This DOCUMENT Is THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED AS DATED, ALL RIGHT S RESERVED. ALITHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF THIS DOCUMENT I5 NOT TRANSFERABLE THE REORIENT OF HIS DOCUMENT LS HEREBY ADVISED THAT R IS RELEASED FOR IAE LMDER THE FOLLOWING TERMS AND CONDRION THE DOCUMENT LS TO BE USED ONLY IN CO W UN CRON WITH TF#S PROJECT. REUSE OF ANY PORTION OF THE DONMENT N ANY OTHER CJRWMSTMTCE CONSTRUTES COPYRIGHT INFRINGEMENT. THE DOCUMENT is FOR DESIGN INTENT AND INFORMATION ONLY, AND DOES LO =CONSTTTULE AS-BULT CONDRIONT. THE RECBIENT RETAINS THE OBLJGATION TO V6LEYTHE CONDRIONs OF THE SUBJECT FROFERTY AND TO COMPLETELY cOOR *IMR ATL DIMENSIONS, FABRICATION METHODS, RELATED AND MTEGRATED SYSTEMS, ETC. WITH RESPECT TO ALL ASPECTS OF THE WORK EPOOT DESIGN GROUP MAKES NO WARRANTY AS TO THE SUTABILTI'Y OF THE DOCUMENT FOR THE RECEENT'S ATTENDED USE. TEE RECEENT SPEOHCALLY AGREES TO WANE AND TO INDEMNIFY AND DEFEND ANY AND AU CLAIMS AGAINST EFOGl DESIGN GROUP, ITS CONSULTANTS, ANY OF ITS RELATED ENPRIET. Vf340ORS, OR CONTRACTORS, FOR ANY LOss INCURRED AS A RESULT OF PROPER OR IMPROPER USE OF His DOOJMEM. PROJECT TITLE: cir) w No,Q Revision Description Date SHEET TITLE: HVAC SPECIFICATIONS AND DETAILS DRAWN BY: JCC ISSUE DATE: 11/07/07 a D D u 0 W y X t!] W W La- � • 0 0 k l '— RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913 - 322 -5150 FAX= 913 -322-5155 on PROJECT NO.: SHEET NUMBER: 07073 M2 HANGER STRAP SCHEDULE DUCT SIZE HANGER SIZE MAXIMUM SPACING UNDER 2 S.F. 1 "x1 /16" 6' -O" 2 S.F. TO 4 S.F. 1"x1/8" 6' -0" 4 S.F. TO 10 S.F. 1"x1/8" 6' -0" OVER 10 S.F. 1"x1/8" 4'--0" W 1 /2xW 24" MIN CONNECTIN FULL SIZE OF RETURN AIR GRILLE RETURN AIR GRILLE AIR FLOW END OPEN RETURN AIR BOOT DETAIL NOT TO SCALE METAL DECK WELDED STUD SELF - TAPPING SCREWS W /WASHER BOTTOM SCREWS MAY BE OMITTED IF HANDER LOOPS EXPANSION SHEILD (BSA NO. 390 -58 SM) SLAB HANGER STRAPS NOTE: ALL ANCHORS AND INSERTS SHALL HAVE N.Y.C. BOARD OF STANDARDS AND APPEALS APPROVAL. DUCT MOUNTING DETAIL NOT TO SCALE 17 DETAILS MECHANICAL DESIGN & CONSTRUCTION CRITERIA GENERAL NOTES: REFER TO MECHANICAL OUTLINE SPECIFICATIONS FOR ADDITIONAL EQUIPMENT, MATERIALS AND INSTALLATION REQUIREMENTS. ALL TENANT MECHANICAL SYSTEMS AND EQUIPMENT SHALL BE INSTALLED, BRACED AND INSULATED IN ACCORDANCE WITH ALL LOCAL CODE REQUIREMENTS. ALL TENANT EQUIPMENT ON THE ROOF SHALL BE LABELED WITH TENANT NAME AND SUITE NUMBER. ALL ROOF PENETRATIONS SHALL BE MADE AT THE TENANT'S EXPENSE BY A LANDLORD APPROVED ROOFING CONTRACTOR PER THE LANDLORD SPECIFICATIONS. ALL WATERPROOFING SHALL BE DONE AT THE TENANTS EXPENSE BY A LANDLORD APPROVED WATERPROOFING CONSULTANT PER THE LANDLORD SPECIFICATIONS. ON COMPLETION OF INSTALLATION, TENANT SHALL OBTAIN AT THE TENANT'S EXPENSE, A SPECIAL INSPECTION SIGN-OFF FROM THE LANDLORD'S DESIGNATED ROOFING CONTRACTOR AND SHALL DELIVER PROOF OF SIGN -OFF TO THE LANDLORD TENANT COORDINATOR REPRESENTATIVE ON SITE. RIGID HVAC DUCTWORK SHALL BE SHEETMETAL, GALVANIZED STEEL OR ALUMINUM. FIBERGLASS "DUCT BOARD" OR OTHER NONMETALLIC MATERIAL IS NOT ACCEPTABLE. KITCHEN GREASE AND DISHWASHER EXHAUST DUCTS SHALL BE 18 -GAUGE STAINLESS STEEL SHEETMETAL WITH CONTINUOUSLY WELDED JOINTS AND SEAMS. KITCHEN GREASE EXHAUST DUCTS SHALL BE WRAPPED CONTINUOUSLY WITH AN APPROVED FIRE WRAP PRODUCT. MINI - ANCHOR RETAIL TENANT SPACES: TENANT SHALL PROVIDE AND INSTALL ALL ROOFTOP HEATING, VENTILATION AND AIR - CONDITIONING EQUIPMENT REQUIRED FOR THEIR SPACE AT LOCATIONS DESIGNATED BY LANDLORD. TENANTS SHALL PROVIDE AND INSTALL DUCTWORK WITHIN THEIR SPACE; TENANTS SHALL ALSO PROVIDE AND INSTALL DUCTWORK THAT EXTENDS FROM THEIR SPACE TO THE ROOFTOP EQUIPMENT LOCATIONS WITH ROUTING AND FLOOR, ROOF OR WALL PENETRATIONS AS DESIGNATED BY LANDLORD. GREASE EXHAUST OUTLETS SHALL BE UPBLAST TYPE AND SHALL BE INSTALLED SUCH THAT THE OUTLET IS EVEN WITH THE TOP OF SCREEN WALLS FOR ROOFTOP MECHANICAL AREAS. TENANT SHALL PROVIDE LANDLORD WITH COPIES OF SERVICE REPORTS FOR GREASE DUCT MAINTENANCE AND GREASE MITIGATION ON ROOF AROUND GREASE EXHAUST HANDLING EQUIPMENT. IF LANDLORD DEEMS NECESSARY, LANDLORD WILL PROVIDE GREASE MITIGATION AT TENANT'S EXPENSE. RETAIL TENANT SPACES: LANDLORD PROVIDES CONDITIONED SUPPLY AIR FROM VAV ROOFTOP AIR - CONDITIONING UNITS DUCTED TO TENANT SPACES FOR COOLING AND VENTILATION. TENANT SHALL CONNECT TO DUCT STUBS FROM THIS SYSTEM AND PROVIDE AND INSTALL FAN - POWERED VAV TERMINAL UNITS WITH ELECTRIC REHEAT TO PERFORM ENVIRONMENTAL CONTROL OF THEIR SPACE. COOLING AIRFLOW ALLOWANCE FROM LANDLORD SYSTEM IS A NOMINAL 350 SQUARE FEET PER TON IN RETAIL TENANT SPACES. TENANT TOILET OR GENERAL EXHAUST FANS SHALL DISCHARGE INTO COMMON EXHAUST DUCT STUBS PROVIDED BY LANDLORD. TENANT EXHAUST FANS SHALL BE LOCATED WITHIN THE TENANT SPACE AND SHALL BE EQUIPPED WITH INTEGRAL BACKDRAFT DAMPERS. FIRE SUPPRESSION SYSTEM DESIGN CRITERIA GENERAL NOTES: TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER MAIN OR CROSS MAIN WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, TUKWILLA FIRE DEPARTMENT, AND LANDLORD'S INSURANCE CARRIER. ALL FIRE SPRINKLERS IN THE PUBLIC ZONE OF THE TENANT SPACE SHALL BE FULLY RECESSED WITH COVER PLATES. SPRINKLER LAYOUT AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO THE LATEST ISSUE OF NFPA 13. PIPE SCHEDULE METHOD MAY BE USED TO SIZE BRANCH PIPING PROVIDED THE CROSS -MAINS FURNISHED BY THE LANDLORD ARE ADEQUATELY SIZED. TENANT SHALL ENGAGE THE SERVICES OF A QUALIFIED SPRINKLER CONTRACTOR SUBJECT TO LANDLORD REVIEW AND APPROVAL. A LIST OF SUGGESTED SPRINKLER CONTRACTORS IS PROVIDED IN THE GENERAL INFORMATION SECTION OF THIS BOOK. ALL SPRINKLER HEADS INSTALLED BY THE TENANT SHALL BE LISTED FOR THE TENANT'S APPLICATION. RESTAURANT AND FOOD COURT TENANTS WITH ONE OR MORE TYPE I HOODS WITHIN THEIR SPACE, SHALL PROVIDE SUCH HOODS WITH SELF CONTAINED FIRE SUPPRESSION SYSTEMS. TENANT SHALL PROVIDE AND INSTALL APPROPRIATE -TYPE FIRE EXTINGUISHERS IN STOCK ROOM AREAS AND ELSEWHERE THROUGHOUT THE DEMISED PREMISES, AS REQUIRED BY ALL LOCAL AUTHORITIES HAVING JURISDICTION AND LANDLORD'S INSURANCE CARRIER. FIRE EXTINGUISHERS SHALL BE FURNISHED, AS DIRECTED BY THE FIRE MARSHAL AND BE EASILY ACCESSIBLE. AS A MATTER OF ROUTINE PRACTICE, FIRE EXTINGUISHERS SHALL BE SERVICED AND INSPECTED MONTHLY. LANDLORD WORK: LANDLORD SHALL PROVIDE A COMPLETE HYDRAULICALLY DESIGNED SPRINKLER SYSTEM WITH THE CROSS -MAINS SIZED WITH 40% ADDITIONAL CAPACITY FOR TENANT IMPROVEMENT. THE CROSS -MAINS SHALL BE INSTALLED BY LANDLORD WITH CAPPED STUB -OUTS IN EVERY BAY FOR TENANT CONNECTION. LANDLORD MAY FURNISH, AS DEEMED NECESSARY AND AT TENANT'S EXPENSE, A SPRINKLER SYSTEM FOR THE TENANT SPACE THAT IS IN COMPLIANCE WITH ALL LOCAL CODES AND LANDLORD'S INSURANCE CARRIER. FIRE EXTINGUISHER: AS REQUIRED BY LOCAL CODE, THE TENANT SHALL FURNISH AND INSTALL A 2A -20B: C RATED FIRE EXTINGUISHER. PLUMBING DESIGN & CONSTRUCTION CRITERIA GENERAL NOTES: REFER TO MECHANICAL OUTLINE SPECIFICATIONS FOR EQUIPMENT, MATERIALS AND INSTALLATION REQUIREMENTS. ALL TENANT PLUMBING SYSTEMS AND EQUIPMENT SHALL BE INSTALLED, BRACED AND INSULATED IN ACCORDANCE WITH ALL LOCAL CODE REQUIREMENTS. TENANT SHALL DESIGN AND DEVELOP A COMPLETE PLUMBING SYSTEM AS NEEDED WITH ALL THE NECESSARY FACILITIES TO SERVE THE DEMISED PREMISES. THIS INCLUDES INSTALLING A SANITARY SEWER AND VENT SYSTEM, A DOMESTIC HOT AND COLD WATER SYSTEM AND GAS SYSTEM. TENANT SHALL MAKE ALL CONNECTIONS TO THE EXISTING UTILITY SERVICES PROVIDED BY LANDLORD. DOMESTIC WATER: A DOMESTIC WATER SERVICE DISTRIBUTION SYSTEM AND VALVED OUTLET CONNECTION SHALL BE LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE. THE OUTLET SHALL BE SIZED AS FOLLOWS: 1 : FOR RETAIL TENANTS OF LESS THAN 10,000 SQUARE FEET, THE WATER SERVICE SHALL BE 3/4 ". 2 : FOR RETAIL TENANTS OF 10,000 SQUARE FEET OR MORE, THE WATER SERVICE SHALL BE 2 ". 3 : FOR RESTAURANT TENANTS, THE WATER SERVICE SHALL BE 3 ". 4 : FOR FOOD COURT TENANTS, THE WATER SERVICE SHALL BE 2 ". 5 : FOR WET KIOSKS, THE WATER SERVICE SHALL BE % ". TENANTS MAY HAVE ACCESS TO LARGER WATER SERVICES IF AVAILABLE AND SUBJECT TO LANDLORD REVIEW, ACCESS SHALL BE OBTAINED AT TENANT'S COST. TENANTS WITH HIGH WATER USAGE (I.E. RESTAURANTS, CAFES, FOOD SERVICE, SALONS, PET SHOPS, ETC.) SHALL PROVIDE AND INSTALL A DOMESTIC WATER SUB- METER, PER LANDLORD'S SPECIFICATIONS. THE METER SHALL BE LOCATED INSIDE THE TENANT SPACE AND SHALL HAVE A READOUT IN AN ACCESSIBLE LOCATION AT 5' ABOVE THE FINISHED FLOOR, TENANTS SHALL PROVIDE AND INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER ON THEIR WATER SERVICE WITHIN THEIR SPACE PRIOR TO MAKING ANY OTHER CONNECTIONS TO THE WATER SERVICE PIPING. WATER PIPING SHALL BE TYPE L HARD COPPER TUBE ABOVE GRADE AND TYPE K SOFT COPPER TUBE BELOW GRADE. TENANTS ARE RESPONSIBLE FOR PROVIDING THEIR OWN DOMESTIC WATER HEATERS WITHIN THEIR OWN SPACE. WATER HEATERS SHALL BE ELECTRIC. SANITARY SEWER AND VENT: A SANITARY SEWER SERVICE MAIN LINE AND 4" PLUGGED POINT OF CONNECTION SHALL BE PROVIDED BY LANDLORD BENEATH THE SLAB FOR EACH TENANT SPACE. ALL POINTS OF CONNECTION SHALL BE AT A LOCATION AND INVERT ELEVATION SELECTED BY THE LANDLORD. LOCATION SHALL BE FIELD VERIFIED BY TENANT. FOR TENANT SPACES ON THE GROUND FLOOR, A 4" STUB -UP TO THE FLOOR IS PROVIDED BY LANDLORD WITHIN THE TENANT SPACE FOR USE IN LOCATING THE CONNECTION POINT. TENANTS ON THE GROUND FLOOR REQUIRING BELOW -GRADE WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB DEMOLITION TO PREVENT DISTURBANCE OF LANDLORD'S BELOW-GRADE UTILITIES, ON COMPLETION OF BELOW - GRADE WORK, TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND PATCHING OF THE SLAB -ON -GRADE SYSTEM, INCLUDING GRAVEL LAYERS, VAPOR BARRIER, AND CONCRETE. TENANT SHALL COORDINATE WITH LANDLORD TO PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION AND PHOTOGRAPHIC DOCUMENTATION BY LANDLORD OF BELOW GRADE WORK PRIOR TO THE COVERING UP OF SUCH WORK. 1 : FOR EACH RESTAURANT TENANT, A DEDICATED 4" GREASE WASTE LINE IS AVAILABLE WHICH TERMINATES INTO A DEDICATED GREASE INTERCEPTOR OUTSIDE THE BUILDING IN THE PARKING LOT. THE GREASE WASTE LINE WILL BE INSULATED AND HAVE ELECTRIC HEAT TRACE FOR TEMPERATURE MAINTENANCE, POWER FOR THE ELECTRIC HEAT TRACE WILL COME FROM THE TENANT'S ELECTRICAL PANEL, TENANT SHALL PROVIDE LANDLORD WITH COPIES OF SERVICE REPORTS REGARDING MAINTENANCE OF THEIR DEDICATED GREASE INTERCEPTOR PER THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY- ACCEPTED STANDARDS. LANDLORD MAY PROVIDE, AS DEEMED NECESSARY AND AT TENANT'S EXPENSE, GREASE INTERCEPTOR MAINTENANCE. 2 : FOR FOOD COURT TENANTS, A COMMON 4" GREASE WASTE LINE IS AVAILABLE WHICH TERMINATES INTO A COMMON GREASE INTERCEPTOR OUTSIDE THE BUILDING IN THE PARKING LOT. A CAPPED 3" SANITARY VENT CONNECTION SHALL BE LOCATED WITHIN OR ADJACENT TO THE TENANT SPACE, IN THE CEILING AT A LOCATION AND ELEVATION SELECTED BY THE LANDLORD. SANITARY WASTE AND VENT PIPING SHALL BE CAST IRON WITH "NO -HUB" COUPLINGS. VENT PIPING 1 -1/2" AND SMALLER, ABOVE GRADE, MAY BE SCHEDULE 40 GALVANIZED STEEL PIPE WITH THREADED COUPLINGS. RECEIVED CITY OF TUKWILA DEC 1 1 2007 PENIVIIT CEN I ER 17 MALL NOTES t J 4 PATWI ( 1) $ j I O PROJECT TEAM Architect: Epoch Design Group, Inc. 1 155 011vette Exec. Pkwy. Suite 100 St. Louis, MO 63132 TEL 314.721.1340 FAX 314.721.0344 M. E. P. & F.P. Engineer: COPYRIGHT DISCLAIMER: 4 R4 RI Nr y ro m Iii Ui O E z 5 CL L1-1/ U. RANDALL A. NELSON 8016 Reeder Rd. Lenexa, KS 66214 TEL, 913 - 322.5150 FAX. 913 - 322 -5155 TI DOCUMENT Is THE PROPERTY OF EPOCH DESIGN GROUP, COPYRIGHTED AS DATED, All I1OFRS RESERVED. AUTHORIZATION FROM EPOCH DESIGN GROUP FOR USE OF TIM DOCUMENT IS HOT TRANSFERABLE. THE RECIPIENT OF THIS DOCUMENT Is HEREBY ADVISED THAT IT (5 RELEASED FOR USE UNDER THE FOLLO WNG TERMS AND CONDITIONS, THE DOCUMENT IS TO BE USED ONLY IN CONJIINUION WITH THIS PROJECT. REUSE OF ANY PORTION OF THE DOCJMEJTT N ANY OTHER CRCUMSTMJCE CONSTITUTES COPYRIGHT NFRNGEMEHT. THE DOCUMENT t5 POR DESIGN INTENT AND INFORMATION ONLY AND DOES NOT CONSTITUTE AS -SLIILT CONDITIONS. THE REW EH T RETAINS THE OBLIGATION TO VERIFY THE OD/MITI-OHS OF THE SUBJECT PROPERTY AND TO COMPLETELY COORDINATE ALL DIMENSIONS, FABRICATION METHODS, RELATED AND INTEGRATED SYSTEMS, ETC, WITH RESPECT TO All ASPECTS OF THE WORK. EPOCH DESIGN GROUP MAKES HO WARRANTY AS TO THE SUTTABILJTY OF THE DOCUMENT FOR THE RECIPIENTS INTENDED USE. THE RECIPIENT SPECIFICALLY AGREES TO WAIVE AND TO INDEMNIFY AND DEFEND ANY AND ALL CLAIMS AGAINST EPOCH DESIGN GROUP, ITS CONSULTANTS, ANT OF ITS RELATED ENTRIES, VINDOR5, OR CONTRACTORS, FOR ANY LOSS INCURRED AS A RESULT OP P _• - = 1, _ .a- USE OF THRS DOCUMENT. Ex�1REs 1:I d I PROJECT TITLE: No-A Revision Description Date SHEET TITLE: MALL NOTES PROJECT NO.: SHEET NUMBER: 07073 DRAWN BY: JCC ISSUE DATE: 11/07/07 a � W w0 Z w t!?V C1- to M3