HomeMy WebLinkAboutPermit M07-273 - WESTFIELD SOUTHCENTER MALL - MAC COSMETICSMAC COSMETICS 807 SOUTHCENTER MALL M07 -273 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: DEB SHIELDS, NW PERMITS INC Address: 1345 GULF RD , POINT ROBERTS WA Contractor: Name: DAVID A NICE BUILDERS INC Address: 4571 WARE CREEK RD , WILLIAMSBURG VA Contractor License No: DAVIDNB044QL DESCRIPTION OF WORK: MECHANICAL WORK FOR TENANT IMPROVEMENT Value of Mechanical: $50,900.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 807 SOUTHCENTER MALL TUKW MAC COSMETICS 807 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA MECHANICAL PERMIT Fees Collected: $557.61 International Mechanical Code Edition: 2006 EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360 - 945 -2787 Phone: 757 566 -3032 Expiration Date: 04/18/2009 M07 -273 03/03/2008 08/30/2008 Boiler Compressor: 0-3 HP/ 100,000 BTU 0 3 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -273 Printed: 03 -03 -2008 Permit Center Authorized Signature: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and e governing this work will be complied The granting of this permit does not construction or the performanc Permit Number: M07 -273 Issue Date: 03/03/2008 Permit Expires On: 08/30/2008 Date: / 1 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. ume to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit. Date: Signature: 2 1 2-41-4- rg Print Name: (1-Q7,v y This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspende< or abandoned for a period of 180 days from the last inspection. M07 -273 Printed: 03 -03 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond -10/06 807 SOUTHCENTER MALL TUKW MAC COSMETICS 5: ** *FIRE DEPARTMENT CONDITIONS * ** sie City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M07 -273 ISSUED 12/12/2007 03/03/2008 1: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 2: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 3: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 7: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 8: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (I1VIC 606.1, 606.2.1) 9: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 10: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 11: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 13: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 14: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of M07 -273 Printed: 03 -03 -2008 such condition or violation. doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http. / /www.ci.tukwila.wa.us 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** M07 -273 Printed: 03 -03 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: i Date: /� or Print Name: --Out liver 44 doc: Cond -10/06 M07 -273 Printed: 03 -03 -2008 Site Address: - . .y.), ; - 14, ,,• �,,� ar ,� Tenant Name: Property Owners Name: Mailing Address: Company Name: TBP Mailing Address: CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: J Dv 1 ci Q1AppliationAFonm- Applications On Line13 -2006 - Permit Appliation.doc Revised: 9 -2006 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** W, King Co Assessor's Tax No.: 4 ) - 0 7 I1v`e.. .1c (0rf o rs- tt tl a 61 UIISL(s Rlvc 1444' P a c t- Name: D io S L L: le) s N w Pe r AA L1 - Mailing Address: (?)4 t f2c) E -Mail Address: hko 19- 42vr►ai ', Cpl GENERAL IC} t I40ward 5 Si •E Contact Person: 'K RA AA; it ker E -Mail Address: Suite Number: K i t d Floor: 1 Cit City Day Telephone: Fax Number: New Tenant: .... Yes D ..No r A State State 9 deg ?.,5 Zip Day Telephone: 3C,0 q '4 S 2_78'7 City state Zip Fax Number: - �J 6 5 2 0 c I UNTRACTOR INFORMATI — (Cbtltractor Infor mation for Mechanical {pg it) £or Plumlitng an Gas Pipiitg Zip Expiration Date: Mans must be wet stanp 34-V1 :: an cisco CA c 1q1 0 S City State Day Telephone: 415 - 371 -0 70C3 Fax Number: 415 - 3 7 j 8 00 Zip et s tami eer of Recoir City State Zip Day Telephone: 4 1 5 ' 4 89 - 7 2- i0 E -Mail Address: Fax Number: 4 1 5 439 - 7Z3 9 Page 1 of 6 Unit Type:. Qty Jnit,Type Qty > 'Unit T�ple :' '', Qty . Boilerl,Coai ressar: P ` Furnace<100K BTU Air Handling Unit >10, CFM i Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser y4 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct fa,'k Thermostat I 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater , Ventilation System ' Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical uipment ICtl,. (X NA; ° "' ' -� 1 1 ..rr Air Handling Unit <10,000 CFM Incinerator — Comm/Ind 4`f1.✓1Nlt oeti i , _ i tvIELAclA v1t,AL rLltivu 1 J.XNI - MA 11UIN .- 206-431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: D Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Mechanical work (contractor's bid price): $ 0 , ci I C C Scope of Work lease provide detailed information): V .. t1-h I vl S l;I 3 i-<a. -v� ; c . ( f5 i S A7"Avt.. .xNc:ii \- '1"Cl+rt -c7' r• e yvk Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Er Replacement .... ❑ Fuel Type: Electric Et Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: t . c 11 Q:\Appliations\Fonns- Appliations On Line'3 -2006 - Permit Application.doe Revised: 9 -2006 bh city Day Telephone: Fax Number: State Zip Expiration Date: Page 4 of 6 PERMIT APPLICATION NOT— Applicable to all permits in this a Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Print Name: Mailing Address: Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 • • - J ED GENT: Signature: CJ ' C Date Application Expires: Date Application Accepted: ; .L ! ...0 7 Q:%Appliations\Fonna- Applications On Lincu -2006 - Permit Application.doc Revised: 9 - 2006 bh Day Telephone: City Date: State Zip Page 6 of 6 Receipt No.: R08 -00592 Payee: DAVID A NICE BUILDERS INC ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M07 -273 Address: 807 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/12/2007 Applicant: MAC COSMETICS Issue Date: Initials: JEM Payment Date: 03/03/2008 10:25 AM User ID: 1165 Balance: 50.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 12074 314.89 Account Code Current Pmts 000/322.100 314.89 Total: $314.89 Payment Amount: 5314.89 9320 03/03 9710 TOTAL 314.89 rtnr RAmint -OR PrintRri! fl -AI-20M Receipt No.: R07 -02737 Payee: WILLIAM DUFF ARCHITECT ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M07 -273 Address: 807 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/12/2007 Applicant: MAC COSMETICS Issue Date: Initials: WER Payment Date: 12/12/2007 09:08 AM User ID: 1655 Balance: $314.89 TRANSACTION LIST: Type Method Description Amount Payment Check 2143 137.20 Account Code Current Pmts 000/322.100 137.20 Total: $137.20 Payment Amount: $137.20 5955 12/12 9710 TOTAL 3961.04 doc: Receiot -06 Printed: 12 -12 -2007 Receipt No.: R07 -02734 Payee: WILLIAM DUFF ARCHITECT ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M07 -273 Address: 807 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/12/2007 Applicant: MAC COSMETICS Issue Date: Initials: WER Payment Date: 12/12/2007 09:01 AM User ID: 1655 Balance: $452.09 TRANSACTION LIST: Type Method Description Amount Payment Check 2143 105.52 Account Code Current Pmts 000/345.830 105.52 Total: $105.52 Payment Amount: $105.52 5955 12/12 9710 TOTAL 3961.04 doc: Receiot -06 Printed: 12 -12 -2007 Project: Type of Inspection: Address; � v7 771/914 Date Called: Special Instructions: Date W nted: � — <� �-f� p.m. Requester: Phone No: o2. Z ( % - 'i9> INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 K Approved per applicable codes. Corrections required prior to approval. COMMENTS: , /rt €c.l Cif P 'Inspector: 'Receipt No.: A / rate: 7 /e /U El $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Date: COMMENTS: Tye of Inspection: 5 r . let •- ,t_ r,.i e o d ;,,, VAv -2 r �] J gK4Kvh 1 44,14„ , ,5 rio. (/�� ASS•PCI c3(o - / p cV Vt. S v1 4 L (- I L. V AV- I Ir ‘ ..1 j rs9 Av Uc - eAgej `7. r v.4 S Pall,- L,1 G t Z Project: r' I A 4- Tye of Inspection: 5 r . let •- ,t_ r,.i e o d ;,,, Address: e 01 0 14 L L Date Called: Special Instructions: Date Wanted: ? /60, / U a.m. p.m. Requester: Phone No: 7 0 2 ' - ' 5 . . 1 2 4 1 2 _ 6 -273 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspector: t L / 6 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 'Inspector: 1407 Pr IT NO. (206)431 -3670 Project: /j Address: /O7 114, (a Special Instructions: Type of Inspection:, rJ,1/ Date Called: Date Wanted: 7/574F Requester: Phone No: 7o2 '7 '7 M Corrections required prior to approval. COMMENTS: V e c/ l;'rr_ -/ ,el be4rP T�c7 7f s 4S oav,I t S in0 k Api9ral/P (Date: 7/3,% p J $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid a 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: � c r /� l 1*, & Type of Inspection: ` �La- � J■t ('\t`. Address: Mn \ 1 pA \ Date Called: Special Instructions: Date Wanted: a.m. • \ - ©? p.m. Requester: Phone No: tS - 459 - ?iyZ I " Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t �- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 3670 Approved per applicable codes. COMMENTS: A00 --\r> Q * 4-D c j Ilnspector: l,^ ,Date: I $ n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: INSPECTION RECORD Kin Corrections required prior to approval. 'Date: INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION II- _Ir 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: (I) tit 5 Address: < �i MRLL Special Instructions: INSPECTION RECORD 1 Retain a copy with permit i ' l Ty a of Insp ection: c 5hk + d 9W►.� Date Called: Date Wanted: `r /OS a.m. p.m. Requester: Phone No: El Approved per applicable codes. COMMENTS: _f ted c�rc�q ■hSN ÷e$ ( t 'cl r,, . 'Inspector: B Corrections required prior to approval. JDate: / / ? ? � o ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: i I INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION rL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: / i~ r i(I S Address: 40 /77 '9// Spam! Instructions: INSPECTION RECORD Retain a copy with permit me Type of Inspection: Date Called: Date Wanted: p.m. Requester: Phone No: 2-2 V5 -g/62 E1 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 'Inspector: Date: 6- $ FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: I INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: JJ Type of Inspectiga: t C Go6l�ciscS Address: /gel/ Date Called: Special Instructions: 0 Approved per applicable codes. NI Corrections required prior to approval. COMMENTS: 'Inspector: INSPECTION RECORD Retain a copy with permit Date Wanted: // Requester: !/ Phone No: IfYk7 -273 I PERMIT NO. It- (206)431 -3670 1/ft V &-eis i bP u n/i fi ea/ s/e-ill g,/ Lw i 5 :ra 'Date: 6 J 1 / e J $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: i a.m. p.m. - INSPECTION RECORD INSPECTION NO. Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION PER "o. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: ' '1 IM Add Type o spection Ad s: A h 1 &) Date Called: .l► Special Instructions: Date Wanted. Lt 2 - o Requester: Phone No: 0 -25o -0 D Approved per applicable codes. 4 .00 REINSPECTION F c RE ' ED. Prior to inspection. fee must be paid at 6300 Southcente Rh,. Suite 100. Call the schedule reinspection. Date: Corrections required prior to approval. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Special Instructions: Phone No: Addro: Date Wanted: L _ — o Requester: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: (206)431 Approved per applicable codes. I1 Corrections required prior to approval. COMMENTS: "74 Receipt No.: Date — --C.) Date: E REQUI vd., D. Prior to inspection, fee must be te 100. Call the schedule reinspection. Project: CY1 A C.. Sprinklers: Type of Inspection: Address: gO-7 5 , c . Suite #: ill AL c.-- Contact Person: Special Instructions: Pre -Fire: Phone No.: Needs Shift Inspection: r- Sprinklers: Fire Alarm: y Hood & Duct: Ai Monitor: U cA o a , Pre -Fire: N Permits: i Occupancy Type: /r" INSPECTION NUMBER - -Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT f PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Word /Inspection Record Form.Doc 1/13/06 I I Corrections required prior to approval. COMMENTS: r e C , WV-1 (af vej Up.) c („Jv A-) 5 t` fit) b-e_ Inspector: 5 I Date: 7/03 /0 S Hrs.. ❑ $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity2 Btu/1 Total CFM OSA CFM or Econo? SEER or EER IPLV Location FPVAV 01 Applicant Phone: t415l 371 -0900 DTPQ 36000 1485 Econo 10.0 EER NA 3.41 HSPF FPVA 02 150 DTPQ 12000 300 Econo 10.0 EER NA 3.41 HSPF DEC FERMI Fan Equipment Schedule Equip. ID Brand Name Model No. CFM Spt HP /BHP Flow Control Location of Service FPVAV- 01 FP{rAV- 01 Applicant Phone: t415l 371 -0900 594 0.50 0.25 vAv 13640 FPVAV- 02 3.41 HSPF DTPQ 150 0.50 0.17 VAV } EC 5115 5115 3.41 HSPF DEC FERMI Project Info Project Address ,AC SOOTHCENTZR ice, Date 11/19/2007 633 Southcanter Parkway For Building Dept. Use Tukwilla, WA 98188 Applicant Name: William Duff41111111.0 Input Btuh C EY W _ CDR E COMPL.IANCI Applicant Address: 101 Howard treat - Suite H San Francisco, FP{rAV- 01 Applicant Phone: t415l 371 -0900 DTPQ 13640 886 PPR fluic Heating Equipment Schedule Equip. ID Brand Name Model No 1 Capacity Btu/t. Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency's FP{rAV- 01 DTPQ 13640 886 Econo 13640 13640 3.41 HSPF FPVAV- 02 DTPQ 5115 225 Econo 5115 5115 3.41 HSPF Mechanical Summary • MECH -SUM 2004 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. E l Includes Plans Compliance Option 2004 Washin ton State Nonresidential Ener Code Com • liance Form FILE COPY Include menta ti r�semplience ltfMo Irfi on ng r re applicable. 5 Flow control types: variable air volume(VAV). constant volume (CV). or variable speed (V Revised May 2005 JAN 2 2006 Ci Of T kwila 1 kr. 4 0-Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the I plans. For projects without plans, fill in the required information below. t lf available. 2 As tested according to Table 14-IA through 14-1G. 3 1f required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as E IVEL 2007 CENTE 07q- 273 n avauaoie. Hs testea accorcli191026NIVTR 6t(Jr4'itsru."°i % iiffstf.^" `i:A/P,`r(3PF bEfsVM tmciency, orArut, a: applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). RECEIVI DEC 12 2uui PERMIT CEN`I t Mechanical Permit 2004 Washington State Nonresidential Plans Checklist MECH -CHK Energy Code Compliance Forms Revised May 2005 Project Address MAC sotrrstZrrza MALL (Date 11/19/2007 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability Code (yes, no, n.a.) Section I Component f !Information Required I Location on Plans I Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n. a. 1411.1 Combustion htg. Indicate intermittent Ignition, flue/draft damper & Jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans n.a. 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n. a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n. a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans yea 1422 Thermostat interlock Indicate thermostat Interlock on plans yes 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer e r 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary yes 1414.2 Duct insulation Indicate R -value of insulation on duct yea 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.1&2 Drawings & Manuals Indicate requirement for record drawings and operation docs. yes 1416.3.2 Air Balancing Indicate air system balance requirements n.a. 1416.3.3 Hydronic Balancing Indicate hydronlc system balance requirements yes 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report yes 1424 Separate air sys. Indicate separate systems on plans yea Mechanical Summary Form Completed and attached. Equipment schedule with types, Input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 - 1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 Insulation under tank 1442 Shut-off controls Indicate automatic shut-off 1443 Pipe Insulation Indicate R -value of Insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover 2004 Washington State Nonresidential Energy Code Compliance Form no is circled Tor any question, proviae explanation: RECEIVE DEC 12 2007 PERMIT CENTE6- 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14-1G. If a nationally recognized certification program exists for e product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with Input ratings > 225.000 Btu /h (65 kW) shall also have an intermittent Ignition or interrupted device (RD), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with Input ratings > 225,000 Bluth (65 kW), Including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing apace heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the fo lowing: 1411.4 Packaged Electric Heating and Cooling Equlpmen : Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment ahaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. Ate minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut - Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 1412 .4.1 Dampers: Outside air Intakes. exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets In the first story and levels below the first story of buildings three or more stories In height. 1412 .4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels Immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall Indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature In full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: Ilan air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btuth shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 Inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are Isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14-5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) 1 \EC JVB DEC 12 2007 PERMIT CENTEF, EF CAE < 50 gal storage 0.58 0.71 50 to 70 pal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14-1G. If a nationally recognized certification program exists for e product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with Input ratings > 225.000 Btu /h (65 kW) shall also have an intermittent Ignition or interrupted device (RD), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with Input ratings > 225,000 Bluth (65 kW), Including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing apace heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the fo lowing: 1411.4 Packaged Electric Heating and Cooling Equlpmen : Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu /h shall be a heat pump. Exception: Unstaffed equipment ahaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. Ate minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut - Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 1412 .4.1 Dampers: Outside air Intakes. exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets In the first story and levels below the first story of buildings three or more stories In height. 1412 .4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels Immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall Indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature In full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: Ilan air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btuth shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 Inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are Isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14-5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) 1 \EC JVB DEC 12 2007 PERMIT CENTEF, ACTIVITY NUMBER: M07 -273 DATE: 12 -12 -07 PROJECT NAME: MAC COSMETICS SITE ADDRESS: 807 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARjMENTS` fr Building Division 1 Public Works ❑ DETERMINATION O COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural Incomplete Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Documents/routing slip.doc 2- 28-02 611 (2.14 -01 Fire Prevention X Planning Division ❑ Permit Coordinator DUE DATE: 12-18-07 Not Applicable ❑ ❑ No further Review Required El DUE DATE: 01 -15 -08 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information Name License DAVIDNB044QL Expiration Date Licensee Name DAVID A NICE BUILDERS INC • Licensee Type CONSTRUCTION CONTRACTOR UBI 601735264 MOORE, CECIL G Ind. Ins. Account Id 01/01/1980 01/01/1980 Business Type CORPORATION Address 1 4571 WARE CREEK RD Address 2 City WILLIAMSBURG County OUT OF STATE State VA Zip 23188 Phone 7575663032 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/13/1996 Expiration Date 4/18/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date NICE, DAVID A 01/01/1980 NICE, DEBORAH L 01/01/1980 MOORE, CECIL G AGENT 01/01/1980 01/01/1980 tir✓ '� Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVELERS CAS & Until https: // fortress. wa. gov /lnifbbip /printer.aspx ?License= DAVIDNB044QL 03/03/2008 PIPING FITTINGS o PIPE RISE D PIPE DROP o TEE UP ON PIPE .. TEE DOWN ON PIPE t CONTINUATION CAP VALVES VALVE, GENERAL CHECK VALVE CD —SD - —SD— - PLUMBING SYMBOL LIST PIPING SYSTEMS COLD WATER PIPING HOT WATER PIPING CONDENSATE PIPING SANITARY PIPING BELOW GRADE OR FINISHED FLOOR SANITARY PIPING ABOVE GRADE OR FINISHED FLOOR STORM DRAIN PIPING ABOVE GRADE OR FINISHED FLOOR STORM DRAIN PIPING BELOW GRADE OR FINISHED FLOOR SANITARY VENT PIPING HOSE BIBB FLOOR CLEANOUT /GRADE CLEANOUT FLOOR DRAIN FLOOR SINK ABBREVIATIONS AD ACCESS DOOR ABOVE AFF FINISHED FLOOR AFR ABOVE FINISHED ROOF ELECT ELECTRICAL SOV SHUT OFF VALVE V VENT VR VENT RISER W WASTE FILE: 005805M01.DWG - MO1 I EDIT: 11/30/2007 3:44 PM BY MICHAELH I PLOT: 11/30/2007 4:58 PM BY RAY JUACHON O SD ® 0 O ® 0 8 AC -1 12x12 100 2 1 R OMD CD CONT. D DIA EXH F FD FT ID IN LBS. MA MIN. N TS MECHANICAL SYMBOL LIST DUCTWORK SUPPLY AIR RETURN AIR EXHAUST AIR LINEAR /SLOT DIFFUSER ROOM THERMOSTAT EQUIPMENT IDENTIFICATION CD -1 DIFFUSER OR GRILLE IDENTIFICATION DAMPERS VOLUME DAMPER SMOKE DAMPER MOTORIZED DAMPER MOTORIZED DAMPER VOLUME 2 DAMPER W/ REMOTE R OPERATOR ABBREVIATIONS CEILING DIFFUSER CONTINUATION DROP DIAMETER EXHAUST FAHRENHEIT FIRE DAMPER FEET INSIDE DIAMETER INCHES POUNDS MIXED AIR MINIMUM NOT TO SCALE 1 DUCTWORK FITTINGS MITERED ELBOW WITH TURNING VANES RADIUSED ELBOW RECTANGULAR MAIN WITH ROUND BRANCH RECTANGULAR MAIN WITH RECTANGULAR BRANCH CONCENTRIC SQUARE TO ROUND RECTANGULAR OFFSET LESS THAN 15' RECTANGULAR OFFSET MORE THAN 15' ROUND DUCT WITH ROUND BRANCH CONCENTRIC TRANSITION, RECTANGULAR OR ROUND ACCOUSTICALLY LINED DUCT (SIZES SHOWN ARE NET INSIDE) FLEXIBLE CONNECTION POINT OF CONNECTION GENERAL MECHANICAL NOTES 1. THE ENTIRE MECHANICAL SYSTEMS, INSTALLATION AND TESTING MUST BE IN COMPLIANCE TO THE LIFE SAFETY REQUIREMENTS OF THE STATE OF WASHINGTON BUILDING CODE LATEST EDITION. 2. 3. 4. 5. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS AND DRAWINGS. IN THE EVENT OF A DISCREPANCY BETWEEN CONTRACT DRAWINGS AND SPECIFICATIONS, THE MOST STRINGENT SHALL GOVERN. ALL WORK TO BE IN ACCORDANCE WITH REQUIREMENTS OF GOVERNING STATE AND LOCAL FIRE AND BUILDING CODES, NFPA, AND OSHA. INSTALL ALL DUCTWORK TO AVOID ARCHITECTURAL FRAMING, STRUCTURAL MEMBERS, AND OTHER OBSTRUCTIONS. COORDINATE PIPING AND DUCTWORK LOCATION WITH ALL APPLICABLE CONTRACT DRAWINGS PRIOR TO PLACING SLEEVES IN FLOORS OR WALLS. 6. INSTALL ALL DUCTWORK TO BEST SUIT FIELD CONDITIONS AND COORDINATE WITH THE INSTALLATION WORK OF OTHER TRADES. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE EXACT LOCATIONS OF PIPING OR DUCTWORK. 7. SEE ARCHITECTURAL REFLECTED CEILING PLANS TO COORDINATE EXACT DIFFUSER LOCATIONS IN FINISHED CEILING. 8. COORDINATE DUCTWORK WITH STRUCTURAL DRAWINGS, LIGHTING, AUDIO VISUAL AND SPRINKLER SYSTEM. PROVIDE TRANSITIONS AS REQUIRED. 9. PROVIDE ALL MISCELLANEOUS STEEL, SPECIAL SUPPORTS AND ANCHORING FOR ALL MECHANICAL EQUIPMENT REQUIRING SUCH. 10. ALL DUCT DIMENSIONS ARE AIRSTREAM DIMENSIONS. 11. SEAL ALL FIRE RATED PENETRATIONS WITH FIRE RETARDANT MATERIAL AS SPECIFIED. 12. ALL BRANCH DUCTS TO AIR OUTLET SHALL BE EQUIPPED WITH DUCT VOLUME DAMPER. 13. CEILING DIFFUSER SIZES SHOWN ON FLOOR PLANS ARE NECK SIZES. 14. DUCTS STORED ON THE CONSTRUCTION SITE SHALL BE PROTECTED AND ISOLATED FROM DUST AND MOISTURE CONTAMINATION. 15. AT CONTRACTOR DISCRETION HE MAY SUBSTITUTE RECTANGULAR DUCTWORK TO EQUIVILENT SIZE ROUND DUCTWORK, WHERE PHYSICAL OBSTRUCTIONS DO NOT INTERFERE. THE SUBSTITUTION WILL REQUIRE THE CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES. DUCT PRESSURE DROPS AND VELOCITIES MAY NOT EXCEED THAT SHOWN ON BID DOCUMENTS. 16. SEE ARCHITECTURAL DOCUMENTS FOR PAINTING OF ALL EXPOSED DUCTWORK, PIPING, AIR OUTLETS, FIXTURE TRIM, AND MECHANICAL EQUIPMENT. 17. UNLESS SPECIFICALLY SPECIFIED OR SHOWN OTHERWISE ALL CONSTRUCTION IS TO CONFORM TO CMC AND SMACNA HVAC CONSTRUCTION STANDARDS AS A MINIMUM REQUIREMENT. 18. ALL MATERIALS AND WORKMANSHIP ARE SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT. ANY PORTION OF THE WORK FOUND TO BE DEFECTIVE SHALL BE REPLACED BY THE CONTRACTOR AS PART OF THIS CONTRACT AT NO ADDITIONAL COST TO THE OWNER. 19. NOT ALL DUCT AND PIPING TRANSITIONS AND /OR OFFSETS ARE SHOWN. PROVIDE TRANSITIONS AND /OR OFFSETS AT NO ADDITIONAL COST TO OWNER. 20. CONTROLS SHALL BE FURNISHED AND INSTALLED TO MATCH AND BE COMPATIBLE WITH THE BASE BUILDING STANDARD CONTROLS SYSTEM AND SHALL FULLY INTEGRATE WITH THAT SYSTEMS PROGRAM AND INTENT. COORDINATE WITH BASE BUILDING CONTROLS CONTRACTOR. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical g Electrical ,. Iumbing ii Gas Piping City of Tukwila BUILDING DIVISION MO.1 MO.2 M2.1 M2.2 M6.0 SHEET INDEX ,: ;7",37 PERMIT j ,± QUIRED FOR: I MoCh nrcai . .!t'L►iICUI By Date: MECHANICAL LEGEND, NOTES, ABBREVIATIONS MECHANICAL SPECIFICATIONS MECHANICAL FLOOR PLAN & SCHEDULES PLUMBING FLOOR PLAN & SCHEDULES MECHANICAL DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED JAN - 2 2008 City Of Tukwila B ILDIN DIVISION FILE COPY Permit No, Plan review approval is subject to errors and Approval of construction ° e the violation of any adopted code authorize of approved Field Cop Receipt acknowledged: City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees NOT WILLIAM DUFF ARCHITECTS 101 Howard Street. mite E Frcm*c o CA 04105 Issue No. EXPIR 11 - 05-09 INTERFACE (mg. ENGINEERING Contact MICHAEL HYNDING Project 2007 - 0058.05 214 GRANT AVE, SUITE 450, SAN FRANCISCO, CA 94108 PHONE 415.489.7240 FAX 4 Job Title MAC SOUTHCENTER Job Address 633 SOUTHCENTER PKWY TUKWILLA, WA 98188 Sheet Title MECHANICAL LEGENDS, NOTES, ABBREVIATIONS Drawn By: KM Job No. 07025 Scale NONE Sheet No. Checked By: SF RECEIVE. DEC 12 2007 PERMIT (.; N I th t: 415.371.0500 1: 415.371.0300 www.wdorch.com Date M0.1 fler? .i; ': ,• sir• ...... FA[', +.. ,.'.f ✓. rr,_.5' . :.df( +i' i'i'. _i!f<'ne. ..i;l;. %r<• ,.;:hr. ..•r,(rr . . ,........ tiro:..:fir as :4J'!: -R'. �x `_•';.. ,dit::: E.t is; + /5 : -,,,,;:mRfe ;: {' 4J %, r „' >L.'e L' : .,, a ... ; ':< :: u,?i. la;�. P%rS( pr eP y . :;1 ......e.... trrr , s:s�: r - r. a(: r....., ... r > , :r;r, ?er ,: %:7a':[:..., e; Jr'u. , ,rr•f!rr; .. •r,.�r s . DIVISION 15 SPECIFICATIONS: PART 1 - GENERAL PROVISIONS 1.01 REFERENCED STANDARDS A. PUBLISHED SPECIFICATIONS STANDARDS, TESTS OR RECOMMENDED METHODS OF TRADE, INDUSTRY OR GOVERNMENTAL ORGANIZATIONS APPLY TO WORK IN THIS SECTION WHERE CITED BELOW: 1. ASHRAE -- AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS HANDBOOKS. 2. SMACNA - SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION, INC. (A) DUCT CONSTRUCTION STANDARDS. (B) HVAC SYSTEMS TESTING ADJUSTING AND BALANCING. (C) HVAC SEISMIC BRACING GUIDELINES. 3. NEBB - NATIONAL ENVIRONMENTAL BALANCING BUREAU MANUAL PROCEDURAL STANDARDS FOR TESTING - BALANCING - ADJUSTING OF ENVIRONMENTAL SYSTEMS. 4. AABC - ASSOCIATED AIR BALANCE COUNCIL MANUAL: NATIONAL STANDARDS FOR TOTAL SYSTEM BALANCE. 5. ANSI - AMERICAN NATIONAL STANDARD INSTITUTE. 6. ASSE - AMERICAN SOCIETY OF SANITARY ENGINEERING. 7. NFPA - NATIONAL ARE PROTECTION ASSOCIATION STANDARDS; REFERRED TO AS NFPA 90A, NFPA 90B, NFPA 96, ETC. 8. UL - UNDERWRITERS' LABORATORIES, STANDARDS FOR SAFETY; REFERRED TO AS U.S. 181, U.L 555, ETC. 9. IBC - INTERNATIONAL BUILDING CODE. 10. IMC - INTERNATIONAL MECHANICAL CODE. 11. UPC - UNIFORM PLUMBING CODE. 12. IFC - INTERNATIONAL FIRE CODE 13. NEC - NATIONAL ELECTRICAL CODE 14. FDA - FOOD AND DRUG ADMINISTRATION 15. STATE OF WASHINGTON CODE 16. LOCAL CODES B. USE MOST RECENT EDITION OF ALL REFERENCES. C. ABOVE REFERENCED STANDARDS MAY BE SUPERSEDED BY NOTES AND DETAILS ON DRAWINGS AND IN SPECIFICATION. D. WHERE TWO OR MORE REFERENCES CONFLICT, THE MOST STRINGENT, AS DETERMINED BY ARCHITECT SHALL TAKE PRECEDENCE. 1.02 QUALITY ASSURANCE A. ALL EQUIPMENT AND ACCESSORIES TO BE THE PRODUCT OF A MANUFACTURER REGULARLY ENGAGED IN ITS MANUFACTURE. B. SUPPLY ALL EQUIPMENT AND ACCESSORIES NEW AND FREE FROM DEFECTS. C. SUPPLY ALL EQUIPMENT AND ACCESSORIES IN COMPLIANCE WITH THE APPLICABLE STANDARDS LISTED IN ARTICLE 1.01 OF THIS SECTION AND WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES. D. ALL ITEMS OF A GIVEN TYPE SHALL BE THE PRODUCTS OF THE SAME MANUFACTURER. SHOP DRAWINGS - SUBMIT INFORMATION, DRAWN TO ACCURATE SCALE (1/4" = 1' -0"). HIGHLIGHT, ENCIRCLE, OR OTHERWISE INDICATE DEVIATIONS FROM THE CONTRACT DOCUMENTS. DO NOT REPRODUCE CONTRACT DOCUMENTS OR COPY STANDARD INFORMATION AS THE BASIS OF SHOP DRAWINGS. STANDARD INFORMATION PREPARED WITHOUT SPECIFIC REFERENCE TO THE PROJECT IS NOT CONSIDERED SHOP DRAWINGS AND WILL BE REJECTED. SHOP DRAWINGS SHALL COMPRISE OF COORDINATED DUCT, EQUIPMENT, REGISTER, AND PIPING LAYOUTS WITH ALL ELEVATIONS NOTED. E. 1.03 JOB CONDITIONS A. EXAMINE SITE RELATED WORK AND SURFACE BEFORE STARTING WORK OF ANY SECTION. 1. REPORT TO OWNER, IN WRITING, CONDITIONS WHICH WILL PREVENT PROPER PROVISIONS OF THIS WORK. 2. BEGINNING WORK OF ANY SECTION WITHOUT REPORTING UNSUITABLE CONDITIONS OF OWNER CONSTITUTES ACCEPTANCE OF CONDITIONS BY CONTRACTOR. 3. PERFORM ANY REQUIRED REMOVAL, REPAIR OR REPLACEMENT OF THIS WORK CAUSED BY UNSUITABLE CONDITIONS AT NO ADDITIONAL COST TO OWNER. B. CONNECTIONS TO EXISTING WORK. 1. INSTALL NEW WORK AND CONNECT TO EXISTING WORK WITH MINIMUM OF INTERFERENCE TO EXISTING FACILITIES. 2. TEMPORARY SHUTDOWNS OF EXISTING SERVICES: (A) AT NO ADDITIONAL CHARGES. (B) AT TIMES NOT TO INTERFERE WITH NORMAL OPERATION OF EXISTING FACILITIES. (C) ONLY WITH WRITTEN CONSENT FROM OWNER. 3. MAINTAIN CONTINUOUS OPERATION OF EXISTING FACILITIES AS REQUIRED WITH NECESSARY TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. 4. RESTORE EXISTING DISTURBED WORK TO ORIGINAL CONDITION. 1.04 CUTTING AND PATCHING A. PROVIDE ALL CARPENTRY, CUTTING AND PATCHING REQUIRED FOR PROPER INSTALLATION OF MATERIAL AND EQUIPMENT SPECIFIED. B. DO NOT CUT OR DRILL STRUCTURAL MEMBERS WITHOUT CONSENT OF OWNER. SUBMIT A STRUCTURAL ANALYSIS SIGNED BY A REGISTERED STRUCTURAL ENGINEER HIRED BY CONTRACTOR. 1.05 COMMISSIONING A. TEST HVAC CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE SPECIFICATIONS AND DRAWINGS. FUNCTIONALLY TEST SEQUENCES OF OPERATION. B. DOCUMENTATION OF CX, IDENTIFY THE FOLLOWING: 1. PARTIES INVOLVED WITH THE TESTING. 2. EQUIPMENT AND SYSTEMS TO BE TESTED. 3. FUNCTIONS TO BE TESTED. 4. CONDITIONS UNDER WHICH THE TEST PERFORMED. 5. MEASURABLE CRITERIA FOR ACCEPTABLE PERFORMANCE. D. COMMISSIONING REPORTS: 1. PRELIMINARY CX REPORT: PREPARE A PRELIMINARY CX REPORT OF TEST PROCEDURES AND RESULTS AND IDENTIFY THE FOLLOWING: a. DEFICIENCIES FOUND DURING TESTING, WHETHER FIXED OR NOT; STATE CONDITIONS. b. ANY DEFERRED TESTS WHICH CANNOT BE PERFORMED AT THE TIME FOR ANY REASON; STATE CONDITIONS AND ANTICIPATED DATE FOR DEFERRED TEST. 2. FINAL CX REPORT: PREPARE AND FILE A COMPLETED REPORT OF TEST PROCEDURES AND FILE WITH THE OWNER. 1.06 LETTER OF CONFORMANCE A. PROVIDE LETTER AND COPIES OF EXTENDED WARRANTIES WITH A STATEMENT IN LETTER THAT MECHANICAL ITEMS WERE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. INCLUDE LETTER OF CONFORMANCE AND WARRANTIES IN OPERATING AND MAINTENANCE MANUALS. B. WARRANTIES TO BEGIN AT DATE OF SUBSTANTIAL COMPLETION. PART 2 - PRODUCTS 2.01 DUCTWORK MATERIALS A. SHEET METAL: 1. STEEL SHEETS: (A) COLD ROLLED, SOFT STEEL SHEETS. (B) MEETING ASTM 526 -64T. (C) GALVANIZED AS HEREINAFTER SPECIFIED. (D) GALVANIZING: 1-1/4 OUNCES PER SQ FT, TOTAL BOTH SIDES. (1) LOCK- FORMING QUALITY. B. BALANCING DAMPERS 1. GENERAL (A) PROVIDE DAMPERS THROUGHOUT THE DUCT SYSTEMS TO FACILITATE COMPLETE BALANCING. 2 . RECTANGULAR WITH WIDTH OR HEIGHT SMALLER THAN 24 ": (A) BUTTERFLY DAMPERS WITH 18 GA. GALV. STEEL OR DUCT OR DUCT CASING ANGLE REINFORCED AS REQUIRED. RUSKIN OR APPROVED EQUAL 3 . RECTANGULAR WITH WIDTH OR HEIGHT LARGER THAN 24 ": (A) OPPOSED BLADE DAMPERS WITH 16 GA. GALV. STEEL OR DUCT OR DUCT CASING ANGLE REINFORCED AS REQUIRED. RUSKIN OR APPROVED EQUAL. 4. ROUND DAMPERS UP TO 24" DIAMETER: (A) 16 GA. SINGLE THICKNESS STEEL BLADE DAMPERS WITH 18 GA. GALV. STEEL CASING OR DUCT OR DUCT CASING ANGLE REINFORCED AS REQUIRED. RUSKIN OR APPROVED EQUAL C. MISCELLANEOUS PRODUCTS: 1. DUCT SEALANTS: (A) SEALING COMPOUND: SIMILAR TO 3M BRAND NO. 700. (B) TAPE: SIMILAR TO 3M NO. 474. (C) GASKETS: (1) CONTINUOUS, REINFORCED, INERT SELF - CONFORMING TYPE. ( 1/8 IN THICK. (3) WIDTH: TO MATCH ANGLE CONNECTION. (4) SIMILAR TO 3M WEATHERBAN SEALANT TAPE 1202. FILE: 005805MO2.DWG - MO2 I EDIT: 11/30/2007 3:35 PM BY MICHAELH I PLOT: 11/30/2007 4:59 PM BY RAY JUACHON 2. HARD - SETTING JOINT TAPE. (A) TWO PART TAPE: (1) MINERAL IMPREGNATED WOVEN FIBER TAPE. (2) IMPREGNATED WITH ACTIVATOR /ADHESIVE OF POLYVINYL ACETATE TYPE. (B) UL LISTED (1) FLAME SPREAD: 10. (2) SMOKE CONTRIBUTED: 0. (C) SIMILAR TO HARD CAST (R). 3. SPRING FASTENERS: (A) OVAL HEAD STUD AND RECEPTACLE. (B) SCREWDRIVER SLOT. (C) SELF - EJECTING. (D) SIMILAR TO DZUS. 4. ANGLES, TIE ROD AND SHAPES FOR REINFORCING DUCTS. (A) IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS, EXCEPT AS NOTED. 5. DUCT CONNECTION SYSTEM. (A) TRANSVERSE BOLTED DUCT JOINTS. (B) FACTORY FABRICATED COMPONENTS. (C) FLANGES WITH SEALANT, PERMANENT, NON- HARDENING. (D) CORNER PIECES. (E) ASSEMBLE WITH GASKET TAPE. (F) SIMILAR TO DUCTMATE INDUSTRIES " DUCTMATE 25 AND 35." D. TURNING VANES: 1. GALVANIZED STEEL DUCTWORK: GALVANIZED STEEL OR PAINTED BLACK STEEL, EXCEPT AS NOTED. 2. OTHER DUCTWORK: SAME MATERIAL AS DUCTWORK. 3. CONSTRUCTION PER "HVAC DUCT CONSTRUCTION STANDARDS" FOR: (A) SINGLE WALL VANES. (1) WITH 3/4 INCH TRAILING EDGE. (2) USE ONLY IN DUCTS WITH MAXIMUM AIR VELOCITY BELOW 2000 FPM. (B) DOUBLE WALL VANES. (1) USE IN DUCTS WITH AIR VELOCITY OF 2000 FPM OR HIGHER. (C) VANE LENGTH: (1) INDICATED IN REFERENCED "STANDARDS." (D) VANE RUNNERS: (1) PROVIDE SEPARATE EQUAL SIZE SECTIONS FOR VANE LENGTH GREATER THAN THOSE (2) SUBMIT ANY OTHER TYPE FOR APPROVAL (E) ROUND DUCT - FACTORY FABRICATED SPIRAL LOCK SEAM. 2.02 SUPPLY AIR DUCT INSULATION A. DUCT WRAP WITH VAPOR BARRIER: 1. FLEXIBLE FIBERGLASS WRAP, FLAME SPREAD INDEX <25; SMOKE SPREAD INDEX <50, PER ASTM E 84. 2. CONCEALED DUCTS: COVER WITH FLEXIBLE GLASS FIBER INSULATION, K -VALUE AT 75 DEGREES F, MAXIMUM 0.29 BTU- IN /HR -SQ FT DEGREES F, 1.5 PCF MINIMUM DENSITY, WITH FACTORY- APPLIED, GLASS - REINFORCED ALUMINUM FOIL AND KRAFT PAPER VAPOR BARRIER ALL- SERVICE JACKET. MAXIMUM PERMEABILITY OF VAPOR BARRIER TO BE 0.02 PERMS. THICKNESS = 1 -1/2 ". 3. OWENS CORNING OR APPROVED EQUAL 2.03 PIPING AND FITTINGS A. GENERAL 1. PIPING SHALL: (A) BE COMMERCIALLY ROUND AND STRAIGHT AND BE OF UNIFORM QUALITY AND WORKMANSHIP. (B) BE FREE FROM ALL DEFECTS AND BE IDENTIFIED BY SERVICE.. B. PRESSURE PIPING: 1. PRESSURE PIPING SHALL CONFORM TO REQUIREMENTS OF ANSI SAFETY CODE FOR PRESSURE PIPING, B31.1. 2. PRESSURE RATINGS HEREIN ARE STEAM, UNLESS SPECIFICALLY DESIGNATED AS "W.O.G." OR "WATER WORKING PRESSURE ". 3. GALVANIZED STEEL, THREADED: SCHEDULE 40, ASTM A -120 OR A -53. (A) FITTINGS: (1) THREADED, GALVANIZED MALLEABLE -IRON FITTINGS AND GROUND -JOINT UNIONS, ANSI B16.3, 150 PSI CLASS, 2 INCH AND SMALLER. (2) THREADED, CAST -IRON, FLANGES AND FLANGED FITTINGS ANSI B16.1 125 PSI CLASS, AT VALVES AND PIPING SPECIALTIES 2 -1/2 INCHES AND LARGER. 4. COPPER TUBING: (A) (B) (C) (D) (E) (F) (G) ANSI H23.1 TYPE K, L OR M. HARD TEMPER UNLESS INDICATED OTHERWISE. WROUGHT - COPPER, SOLDER JOINT FITTINGS, ANSI B16.22, IN SIZES AVAILABLE. CAST - BRONZE SOLDER -JOINT FITTINGS, ANSI B16.18, ONLY IN SIZES NOT AVAILABLE IN WROUGHT COPPER. CAST- BRONZE, THREADED, GROUND -JOINT UNIONS, ANSI B16.15, 2 INCHES AND SMALLER CAST - BRONZE, FLANGED UNIONS, ANSI B16.24, 150 PSI CLASS, 2 -1/2 INCHES AND LARGER. COPPER TUBING FLARED FITTINGS: BRONZE CASTINGS FOR FLARED TYPE JOINTS, ANSI B16.26. C. DRAINAGE PIPING: 1. SOIL AND WASTE: (A) BELOW GRADE AND BELOW SLAB: STANDARD WEIGHT CAST -IRON, CONFORMING TO ASTM A74, 1Y-SEAL" GASKETED BELL AND SPIGOT. (B) ABOVE GRADE AND BELOW SLAB: CAST -IRON, HUBLESS SERVICE WEIGHT CONFORMING TO ASTM A74, WITH HEAVY DUTY STAINLESS STEEL BANDS, CONFORMING TO FM 1680. 2. VENTS: (A) BELOW GRADE: CAST IRON, GASKETED, SERVICE WEIGHT. (B) ABOVE GRADE: TYPE DWV COPPER TUBING, OR CAST IRON, HUBLESS, SERVICE WEIGHT. 2.04 EQUIPMENT AND FIXTURES A. ALL MECHANICAL /PLUMBING EQUIPMENT AND FIXTURES SHALL BE OF THE MANUFACTURE AND MODEL SPECIFIED ON THE DRAWINGS. ALTERNATE MANUFACTURER'S AND MODEL NUMBERS MAY BE SUBMITTED AS A REQUEST FOR SUBSTITUTION. CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ALL DEVIATIONS FROM THE SPECIFIED MANUFACTURER AND MMODEL NUMBER. PART 3 - INSTALLATION 3.01 DUCTWORK A. GENERAL: 1. CONSTRUCT WITH GAUGES, JOINTS, BRACING, REINFORCING, AND OTHER DETAILS PER LATEST UMC ASHRAE, SMACNA, (OR NFPA) UNLESS SPECIFIED OTHERWISE. COMPLY WITH MOST STRINGENT. 2. CONSTRUCT OF GALVANIZED SHEET METAL (A) CROSS BEADING AT 12 INCHES ON CENTER, MAXIMUM. 3. PROVIDE FOR DUCT RIGIDITY BY EITHER OF THESE METHODS: (A) PROVIDE ADDITIONAL REINFORCEMENT IF "DRUMMING" OR "OIL- CANNING" OCCURS DURING FAN OPERATION. (B) DIAGONALLY CROSS BREAK ALL PANELS ON METAL RECTANGULAR DUCTS OVER 18 INCHES IN EITHER DIRECTION. (1) CROSS BREAK OUTWARD IN DUCTS HAVING POSITIVE INTERNAL PRESSURE. (2) CROSS BREAK INWARD IN DUCTS HAVING NEGATIVE INTERNAL PRESSURE. 4. DUCT DIMENSIONS INDICATED ARE NET, INSIDE, CLEAR, DIMENSIONS. 5. ALTER DUCT SIZES ON BASIS OF EQUAL FRICTION WHERE REQUIRED TO FACILITATE INSTALLATION. 6. AT EXPOSED DUCT PENETRATIONS OF WALLS, FLOORS AND CEILINGS, PROVIDE SHEET METAL ANGLE TYPE ESCUTCHEONS. 7. DUCT OPENINGS. (A) PROVIDE OPENINGS WHERE REQUIRED TO ACCOMMODATE THERMOMETERS, SMOKE DETECTORS, CONTROLLERS, ETC. (1) INSERT THROUGH AIRTIGHT RUBBER GROMMETS. (B) PROVIDE PITOT TUBE OPENINGS WHERE REQUIRED FOR TESTING OF SYSTEMS: (1) COMPLETE WITH METAL CAP WITH SPRING DEVICE OR SCREW TO ENSURE AGAINST AIR LEAKAGE. ( FOR PITOT TUBE TESTS INSTALL VENTLOK NO. 699 AND /OR 699 -2 INSTRUMENT TEST HOLES. (C) WHERE OPENINGS ARE PROVIDED IN INSULATED DUCTWORK FOR INSERTION OF INSTRUMENTS, INSTALL INSULATION MATERIAL INSIDE METAL RING FOR USE AS PLUG. (D) AT FIRE /SMOKE DAMPERS ALLOW ADEQUATE LENGTH OF DUCT TO INSTALL ACCESS DOOR. B. ELBOWS AND SPLITS: 1. USE RADIUS ELBOWS IN RECTANGULAR DUCTS UNLESS OTHERWISE INDICATED. (A) CENTERLINE RADIUS NOT LESS THAN 1 -1/2 DUCT WIDTH. 2. WHERE SPACE DOES NOT PERMIT DUCT RADIUS SPECIFIED ABOVE INSTALL SHORT RADIUS SPLITTER VANESUSE RADIUS ELBOWS IN RECTANGULAR DUCTS UNLESS OTHERWISE INDICATED PER REFERENCED "STANDARDS" (A) NUMBER OF VANES DETERMINED BY RATIO OF INNER RADIUS (R) TO DUCT WIDTH IN PLANE OF RADIUS (W). (1) ONE VANE: R/W ABOVE 0.3. (2) TWO VANES: R/W BETWEEN 0.1 TO 0.3. (3) THREE VANES: R/W 0.1 AND SMALLER. C. RECTANGULAR DUCT JOINTS: 1. STANDING SEAMS, EXCEPT WHERE FLUSH DRIVE SLIP SEAM CALLED FOR. 2. USE FLUSH, DRIVE -SLIP, FOR: (A) EXPOSED DUCTS: (B) WHERE REQUIRED FOR CLEARANCE. 3. "DUCTMATE" SYSTEM JOINTS, MAY BE USED IN LIEU OF STANDING SEAMS. D. JOINT SEALING 1. SEAL TRANSVERSE AND LONGITUDINAL JOINTS OF SHEET METAL DUCTS BY ONE OF FOLLOWING METHODS: (A) SIX OUNCE CANVAS STRIP, SIX INCHES WIDE. (1) ADHERE WITH LAGGING ADHESIVE. (B) HARD CAST PS -S TAPE. (C) UNITED HI- VELOCITY SEALER. (D) APPLICATIONS AS RECOMMENDED BY MANUFACTURER. 2. SEAL PUNCHED HOLES AND CORNER CRACKS. 3. AFTER INSTALLATION AND TESTING RESEAL JOINTS FOUND TO BE LEAKING. 3.02 DUCT HANGERS AND SUPPORTS A. GENERAL: 1. SUPPORT HORIZONTAL DUCTS WITH HANGERS OF SIZE AND SPACING AS INDICATED IN SMACNA PRE-APPROVAL #RO010. 2. ATTACHMENT TO STRUCTURE: EXPANSION ANCHORS B. HORIZONTAL DUCT SUPPORTS: 1. INSTALL SUPPORTS AT EACH CHANGE IN DIRECTION OF DUCT. 2. STRAP HANGERS: 3.03 LABELING A. PROVIDE LABELS ON HORIZONTAL PIPING AT INTERVALS OF NOT MORE THAN 10 FEET APART AND AT LEAST ONCE IN EACH ROOM. LABEL VERTICAL PIPING AT INTERVALS OF NOT MORE THAN 10 FEET APART AND AT LEAST ONCE IN EACH STORY. PROVIDE IDENTIFICATION ON ALL EQUIPMENT AND PIPING SYSTEMS. 3.06 SEISMIC BRACING A. GENERAL: 1. PROVIDE SEISMIC RESTRAINTS FOR DUCTWORK AND EQUIPMENT PER APPLICABLE CODE. 2. DESIGN AND PROVIDE RESTRAINTS TO PREVENT PERMANENT DISPLACEMENT IN ANY DIRECTION CAUSED BY LATERAL MOTION, OVERTURNING, OR UPLIFT. 3. PROVIDE APPROVED RESILIENT RESTRAINING DEVICES AS REQUIRED TO PREVENT EQUIPMENT MOTION IN EXCESS OF 1/4 INCH. 4. CAPABLE OF SAFELY ACCEPTING EXTERNAL FORCES WITHOUT FAILURE. A. SEISMIC RESTRAINT CRITERIA: PER CODE REQUIREMENTS. 5. SHALL NOT SHORT CIRCUIT VIBRATION ISOLATION SYSTEM OR TRANSMIT OBJECTIONABLE VIBRATION OR NOISE. B. DESIGN: 1. PREPARE DESIGNS, INCLUDING ARRANGEMENTS, SIZES AND MODEL NUMBERS INDICATED OR REFERENCED IN APPLICABLE STANDARDS. 2. WHERE DESIGNS, ETC., ARE NEITHER INDICATED NOR REFERENCED, SUBMIT SUCH DESIGNS, TOGETHER WITH SUPPORTING CALCULATIONS PREPARED BY STRUCTURAL ENGINEER REGISTERED IN THE STATE OF UNIFORM. A. CALCULATIONS SHALL SUBSTANTIATE SEISMIC RESTRAINT CAPABILITY TO SAFETY ACCEPT EXTERNAL FORCES WITHOUT FAILURE AND MAINTAIN EQUIPMENT POSITION. 3.07 TESTING AND AIR BALANCING A. BALANCE AIR FLOWS TO CFM'S INDICATED PER AABC STANDARDS, SUBMIT BALANCE REPORT. B. TEST HVAC CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE SPECIFICATIONS AND DRAWINGS. FUNCTIONALLY TEST SEQUENCES OF OPERATION. 3.08 GUARANTEE A. GUARANTEE ALL MATERIALS, EQUIPMENT, APPARATUS AND WORKMANSHIP TO BE FREE OF DEFECTIVE MATERIALS AND FAULTY WORKMANSHIP FOR PERIOD OF ONE YEAR FROM DATE OF FILING OF NOTICE OF COMPLETION. REVIEWED FOR CODE COMPLIANCE APPROVED JAN - 2 2008 City Of Tukwila B DISIo� Mod - 273 WILLIAM DUFF ARCHITECTS 101 Howard Street, Suite E. Si Fri. CA 94105 INTERFACE . t ^ E N G I N E E R I N G Contact MICHAEL HYNDING Project 2007- 0058.05 214 GRANT AVE., SUITE 450, SAN FRANCISCO, CA 94108 PRONE 415.489.7240 FAX 415.489.7289 Issue No. Job Title MAC SOUTHCENTER Job Address 633 SOUTHCENTER PKWY TUKWILLA, WA 98188 Sheet Title MECHANICAL SPECIFICATIONS Drawn By: Checked By: KM SF Job No. 07025 Scale NONE Sheet No. I EXPIRES 11 RECFNEr DEC 1 Ytiul PERMIT CENTEI -, t: 415.371.0900 f 415.371.0600 www.wdordr.00m Date M0.2 ii�r':! %G'h el: roe!!rtS: + %%:.i' !:>: 39es. +e ,!. .CN " /•: ?.£ d' %:,,rt% %. !','e precee env:,, rrlr 8,. r;:=Y1 ! ?:!;.e::, :.�r;.:. f)r.!:v;r� z /. :: ,., %se'..;rr:nd. ?f':.ei•;!or. �I:�!r. % • ...ii el%7rr. ., . !a;� . r .. . .. . ; ! . .. .. e1'!.: •?, V ' �i['i'f (.. .h %i»i%e!e'.: 7.'• ::; i: 111 :' ;'17'.'� "J:'.'nl.f!:'d /'e th fri ^::.'rrttni, r u`r.' %7dy + ^s «f rre .: ;; „ rr ,. ..,. ...r;:• ; e`f ,';llLar :; a : r .. ale!;ij ..,I h ;......-....« ,:,f.r ^ Yr; ,.. r ;, ' Or: :f'er >r`'ie • •:4: @F.:: !'.v.: .rr......, natY DIFFUSER REGISTER AND GRILLE SCHEDULE SYMBOL TYPE SIZE NECK FACE FRAME DAMPEFI FINISH BASIS OF DESIGN REMARKS CD -1 CEILING DIFFUSER 24x24 SEE FLOOR PLANS PERFORATED DUCT NOTE 4 WHITE 1, 2 TITUS PAS CD -2 CEILING DIFFUSER 18x6 SEE FLOOR PLANS LOUVERED BORDER 1 NOTE 4 SAD. TITUS 300 -RS 1, 3, 4 CR -1 RETURN GRILLE 24x24 SEE FLOOR PLANS PERFORATED BORDER 1 NOTE 4 WHITE TITUS PAR 1, 3 CR -2 RETURN GRILLE 12x12 SEE FLOOR PLANS PERFORATED BORDER 1 NOTE 4 WHITE TITUS PAR 1,3 LD -1 CEILING SLOT SUPPLY SEE FLOOR PLANS SEE FLOOR PLANS LINEAR SLOT BORDER 22 - WHITE TITUS FL -25 -HT 1, 5, 6, 7 NOTES: 1. COORDINATE EXACT LOCATION WITH LIGHTS, SPRINKLER HEADS, AND ARCH. RCP. 5. PROVIDE (2) 2.5" SLOT, 10" INLET; BORDER TYPE -22, STRAIGHT PLENUM BOOT AND ALL HARDWARE. 2. USE BORDER TYPE 3 FOR LAY -IN. LENGTH AS SHOWN ON PLANS. 3. BORDER TYPE 1 FOR SURFACE MOUNT IN HARD CEILING. 6. INSTALL YOUNGS REGULATOR AND BOWDEN CABLE CONTROLS #270 -275 MOUNTED INSIDE PLENUM OF 4. FURNISH AND INSTALL FACTORY PROVIDED INTEGRAL DAMPER OPTION. SLOT DIFFUSER WITH #83OACC -2. 7. NO INTEGRAL DAMPERS. FAN SCHEDULE AIR BASS 10 g a FLOW T.S.P. SOUND OF ELECTRICAL SYMBOL AREA TYPE DRIVE (CFM) ON.H2O) (BONES) DESIC44 VOLT /PH EP CONTROL REAAARKS CEF -1 _ _ TOILET CEILING EXHAUST FAN DIRECT 75 0.25 950 2.3 GREENHECK SP -B110 115/1 80W WALL SWITCH 1, 2, 3 NOTES: 1. AMCA CERTIFIED FOR AIRFLOW AND SOUND. 2. PROVIDE ALUMINUM GRILLE(WHITE), THERMAL OVERLOAD, SOUND ABSORBING INSULATION, INTEGRAL BACKDRAFT DAMPER, AND FIELD ROTABLE DISCHARGE. M 07..273 3. PROVIDE WITH ON /OFF SWITH WITH TIME DELAY. 105 ACT = 1 - 10 1103 ACT-1 04 -1 STOCK ROOM P.O.C. RESTROOM - 0 " 75 (E)8 "0 EA 6 "0 CD -1 CD -1 I102 6 "0 -2 8x8 100 AV - -62 .:. :.:.... : ' L 101 CM -2, P Fp v4wL - 01 6 "9s :• yy ; �j i j , 1 (E)16"0 SA 6 "o CD - 1785 CFM, 557 100 - 2 10 - 6" S SCALE: 1/4"=1' 0" FILE: 005805M21.DWG -- M21 I EDIT: 11/30/2007 3:35 PM BY MICHAELH I PLOT: 11/30/2007 5:00 PM BY RAY JUACHON 0 2' 4' 8' 10 "0 ,j. 10"0 \_ 10 "0 • CR -1 5 TYP. 4 8 "0 8 "0 1 MECHANICAL FLOOR PLAN SERIES FAN POWERED TERMINAL UNIT WITH ELECTRIC HEAT SCHEDULE TAG FPVAV -01 FPVAV -02 RAD. 38 28 MODEL DTQS DTQS SIZE UNIT 06 02 INLET 12 06 OUTLET 16.5x14.5 14x11 CFM MAX 1485 300 MIN 450 120 STATIC PRESSURE INLET 0.5 0.5 DOWN 0.5 0.5 MIN. 0.44 0.09 NC LEVELS DIS 19 23 FAN CFM 1485 300 ESP 0.5 0.5 HP 0.75 0.17 ELECTRIC HEAT COIL CFM 1485 300 KW 6.0 2.0 EAT 65 64 LAT 78 85 VOLTS /PH 480/3 480/3 STEPS 2 1 NOTES: 1 2 3 4 5 ROOM NC LEVEL SHOWN INCLUDES ATTENUATION TRANSFER FUNCTIONS OBTAINED FROM TABLES IN ARI STANDARD 885. SOUND DATA SHALL BE OBTAINED FROM TESTS CONDUCTED IN ACCORDANCE WITH ARI STANDARD 880 -98. SELECTIONS BASED UPON TITUS AS MANUFACTURER. ALL CFM, PRESSURE AND HEATING PERFORMANCE VALUES ARE CORRECTED FOR ALTITUDE. SIZE UNITS ARE GIVEN IN INCHES, FLOW UNITS ARE CUBIC FEET PER MINUTE, PRESSURE UNITS ARE INCHES OF WATER, AND TEMPERATURE UNITS ARE DEGREES FAHRENHEIT. PER 2006 IMC SECTION 606 Install smoke detector � combined C ° air F M of all distribution by VAV's when the to t VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See XMC 606.2.2 for approved method of detection GENERAL NOTES 1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. 2, MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES, LANDLORD REQUIREMENTS, CEILING HEIGHTS AND EXISTING STRUCTURAL CONDITIONS PRIOR TO FABRICATION OF ANY DUCTWORK OR ORDERING OF ANY EQUIPMENT. 3, ALL DUCTS SHALL BE LOCATED HIGH AS POSSIBLE TIGHT TO STRUCTURE. 4, ALL BRANCH TAKE -OFFS SHALL BE PROVIDED WITH MANUAL BALANCING DAMPERS. 5. REFER TO MECHANICAL SPECIFICATIONS ON SHEET M0.2. 6. REFER TO MECHANICAL DETAILS ON SHEET M6.0. 7. SEE SHEET M6.0 FOR FAN POWERED VAV UNIT SUPPORT DETAIL. O 0 O 0 O 0 0 SHEET KEYNOTES CONNECT TO EXIST. EXH. DUCT WORK IN CLG. SPACE. SEE DETAIL 6/M6.0. COORDINATE THERMOSTAT LOCATION WITH ARCHITECTURAL DRAWINGS. COORDINATE DIFFUSER FINISH AND LOCATION WITH ARCH. SEE ARCH DWG. (S.A.D.) FPVAV DISCHARGE PLENUM BE FULL SIZE AND ACOUSTICALLY LINED FOR A MINIMUM OF THE FIRST 5'. PROVIDE FLEXIBLE DUCT CONNECTION TO UNIT. PROVIDE TURNING VANES AT ALL MITERED ELBOWS. FOR CEILING RETURN GRILLES CR -1 REFER TO DETAIL 5/M6.0. SEE DETAIL 4/M6.0 FOR CEF -1 INSTALLATION. REFER TO DETAIL 2/M6.0. REVIEWED FOR .I C ODE COMP J,NCE APPROVED JAN - 2 2008 City Of Tukwila B ILDING DIVISION WILLIAM DUFF ARCHITECTS 101 Howard Street. Silts E, San Frar>.ca. CA 04105 z dp INTERFACE E N G I N E E R I N G Contact MICHAEL HYNDING Project 2007 -0058.05 214 GRANT' AVE., SUITE 450, SAN FRANCISCO, CA 94108 PHONE 415.489.7240 FAX 4 Issue No. Job Title MAC SOUTHCENTER Job Address I EXPIRES 11 - ( - 633 SOUTHCENTER PKWY TUKWILLA, WA 98188 Sheet Title MECHANICAL FLOOR PLAN & SCHEDULES Drawn By: Checked By: KM SF Job No. 07025 Scale AS NOTED Sheet No. RECPrfirr DEC 1 �Uu1 PERMIT Lich, o �. t 415.371.0900 is 415.371.0900 www.wdersh.com Date M2 ',';;r :jn ;;r: »s:r rit ;e.ro vir,;i,e ...,ry; :r[ <'ljl.:ata . .,'r .r, 014 d+ >:<.•r < <; .: n.. '.r < . »rr .: siu;.'. %s rrr:rr.. : ar. :r;r ;iuri% vr.•r* u;ur �<' uac.'s:y s�iimie. ,%t<' %;rr _:fr ,n(y,• , ;�F;; , r,,rr. t'. r,....,'r•;?rint. ..... nxsrir ..,..:: .., .the ':r � .,.w;; • .r + i...: <tr. • ,.c ,.itrrrr :Y L %r. ,........... ,H , v +..::fi'�r, ?h: .��'3; •:(: y'•:rr i.:fr'!:. .�,. .. ..... .. 3/8" BOLT, NUT & STAR WASHER THIS HANGER IS FOR DUCTS 24" DIA. & SMALLER CEILING NO SCALE EXHAUST GRILLE ROUND DUCT HANGER " X 1 6Ga. HANGER STRAP, 30" MAX RECTANGULAR DUCT HANGER ATTACHMENT TO STRUCTURE 3 DUCT SUPPORT NO SCALE HEET METAL SCREWS (TYPICAL) AIR FLOW NOTES: 1. -ER TO SPECIFICATIONS FOR HANGER SPACINGS. 2. ATTACHMENTS TO OVERHEAD STRUCTURE SHALL BE MADE IN ACCORDANCE WITH STRUCTURAL ENGINEERS REQUIREMENTS AND WEIGHT LIMITATIONS. ALL ATTACHMENT METHODS TO STRUCTURE SHALL BE SUBMITTED TO ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW. 3. PROVIDE SWAY & SEISMIC BRACING PER SMACNA SEISMIC GUIDELINES AND THE LATEST EDITION OF WASHINGTON BUILDING CODE. CONTRACTOR SHALL INDICATE LOCATIONS OF SEISMIC BRACING ON THE SHOP DRAWING SUBMITTALS. 4. HANGER MATERIAL SUPPORTING FLEXIBLE DUCT SHALL IN NO CASE BE LESS THAN 1 1/2 INCHES WIDE. FLEXIBLE DUCT SHALL BE SUPPORTED PER MANUFACTURER'S RECOMMENDED MATERIALS, BUT AT NO GREATER DISTANCE THAN 4 FEET MAX. PERMISSIBLE SAG IS MAX. 1/2 INCHES PER FOOT OF SPACING BETWEEN SUPPORTS. MIN TWO (2) 12 GA SLACK SAFETY WIRES AT DIAGONAL CORNERS. MIN. 6' -0" LINED DUCT WITH ONE CHANGE IN DIRECTION. SEE PLANS FOR DUCT SIZE. PROVIDE TRANSITION AS REQUIRED (TYP.) NOTE: LIMITED TO FANS WEIGHING 50 LBS. OR LESS 6 CEILING EXHAUST FAN INSTALLATION DETAIL FILE: 005805M60.DWG — M60 I EDIT: 11/30/2007 3:35 PM BY MICHAELH I PLOT: 11/30/2007 5:01 PM BY RAY JUACHON CEILING DIFFUSER HANGER STRAP SECURE TO STRUCTURE AS REQ'D LOCATE WITHIN 2 FT. OF DIFFUSER CENTERLINE. SHARP RADIUS NOT ACCETABLE FLEX DUCT, SEE PLAN FOR SIZE PROVIDE SMOOTH RADIUS TO DIFFUSER CONNECTION, PROPERLY SUPPORT FLEX DUCT FOR SMOOTH AIR FLOW PROVIDE 2 ANGLE CLIPS ON OPPOSITE SIDES OF DIFFUSER SCREW TO T —BAR FOR LAY —IN T —BAR CEILING DIFFUSER (T —BAR LAY —IN & SURFACE MOUNTING SHOWN) 2 CEILING SUPPLY CONNECTION NO SCALE SHEET METAL PLENUM GYP.BD. CEILING U.O.N. NO SCALE PERFORATED CEILING GRILL U.O.N. 5 CEILING RETURN DETAIL 1.5x RADIUS FOR SURFACE MOUNTED CEILING DIFFUSER 8"Wx8 "H BOOT OPN'G. AT OPOSITE SIDES I (ED) -o-- 90' OR 45' RADIUS ELBOW 90' MITER ELBOW 90' TAKE —OFF 15' MAX SIZE TRANSITION DUCT DOWN DAMPER COLLAR SESMIC RESTRAINTS BY MECHANICAL CONTR. CONTR. NO SCALE FAN POWERED VAV UNIT (FPB) ANGLE TAKE —OFF 2 RADIUS TAKE —OFF SD) 90' SPLITTER TAKE —OFF )(SD) RADIUS SPLITTER TAKE —OFF CABLE END #2 NO SCALE 1 DUCT DETAIL NO SCALE CHAMBER COLLAR CRIMPED END (TAPED) —\ CLOSED DAMPER POSITION (3 -E) ADJUSTING SHAFT CLEARANCE HOLE NOTES: SPACERS (2 -A) FAN POWERED CAM SUPPORT BRACKET SUPPORT SCREW (2 -B) 90' OR 45' ELBOW 90' TAKE —OFF SIZE TRANSITION NOTES 1. SINGLE —LINE ILLUSTRATIONS ARE SYMBOLS USED ON DRAWINGS 2. SIZE A &B DIMENSIONS IN PROPORTION TO AIR QUANTITIES IN EACH LEG SPLIT 1. ALL SLOT DIFFUSERS LOCATED IN CEILINGS ARE TO BE PROVIDED AND INSTALLED BY CEILING CONTRACTOR (S.A.D.) MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL PLENUM BOX. 60" MINIMUM FLEX CONNECTION NOTE: 1. PROVIDE SEISMIC BRACING AT ALL FAN POWERED BOXES. USE CBC REQUIRED SEISMIC DESIGN CRITERIA. 2. SUBMITTALS FOR SPRING ISOLATORS AND CONNECTION TO STRUCTURE SHALL BE STAMPED AND SIGNED BY A STRUCTURAL ENGINEER. 3. SPRING ISOLATOR SHALL BE MASON INDUSTRIES OR EQUAL 45' TAKE—OFF 90' CONICAL TAKE ---OFF DUCT DOWN SUPPORT CLIP(1 -A) SET SCREW (1 -B) CAM AIR BAR BULB (TYP) GYP. CEILING (SEE ARCH. DWGS.) 4 SLOT WITH INTEGRAL VOLUME DAMPER ATTACH TO STRUCTURE 1/2" THREADED ROD SPRING ISOLATOR (0.5" DEFLECTION) (MIN OF 4 PER UNIT) PROVIDE STRUCTURAL SUPPORT & BRACING AS PER LATEST SMACNA SEISMIC BRACING CRITERIA. 7 VAV TERMINAL BOX SUPPORT DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED JAN - 2 2005 City Of Tukwila BUILDIN . DIVISION LINED DUCT WITH IN. 1/2" LINING. BRANCH DUCTS Mop- z73 WILLIAM DUFF ARCHITECTS 101 Howard Strict. Suite E. Set Francisco. CA 94105 INTERFACE = I � E N G I N E E R I N G Contact MICHAEL HYNDING Project 2007 - 0058.05 214 GRANT AVE., SUITE 450, SAN FRANCISCO, CA 94108 PHONE 415489.7240 FAX 415.489.7289 Issue No. EIRE 11 5 Job Title MAC SOUTHCENTER Job Address 633 SOUTHCENTER PKWY TUKWILLA, WA 98188 Sheet Title MECHANICAL DETAILS Drawn By: Checked By: KM SF Job No. 07025 Scale NONE Sheet No. RECEIVED DEC 12 2007 PERMIT CENTEE, t: 415.371.0900 * 415.371.0800 www.wordt.corr1 Date M6 ,.•;' ?? c ;•••;ns . >N s. irrcn . .. / .. %;,• ... :;h;•L. %r•s . .. .,n•is<< r:;41 • ;x::..,.. ..e , .,., „. :S,.i;arr, (;•":',.71 12" MINIMUM , r{. I 1 «0 .1 ttr III iiiiiiiiiiiiiiiiiiiiiiiiiiii 3/8" BOLT, NUT & STAR WASHER THIS HANGER IS FOR DUCTS 24" DIA. & SMALLER CEILING NO SCALE EXHAUST GRILLE ROUND DUCT HANGER " X 1 6Ga. HANGER STRAP, 30" MAX RECTANGULAR DUCT HANGER ATTACHMENT TO STRUCTURE 3 DUCT SUPPORT NO SCALE HEET METAL SCREWS (TYPICAL) AIR FLOW NOTES: 1. -ER TO SPECIFICATIONS FOR HANGER SPACINGS. 2. ATTACHMENTS TO OVERHEAD STRUCTURE SHALL BE MADE IN ACCORDANCE WITH STRUCTURAL ENGINEERS REQUIREMENTS AND WEIGHT LIMITATIONS. ALL ATTACHMENT METHODS TO STRUCTURE SHALL BE SUBMITTED TO ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW. 3. PROVIDE SWAY & SEISMIC BRACING PER SMACNA SEISMIC GUIDELINES AND THE LATEST EDITION OF WASHINGTON BUILDING CODE. CONTRACTOR SHALL INDICATE LOCATIONS OF SEISMIC BRACING ON THE SHOP DRAWING SUBMITTALS. 4. HANGER MATERIAL SUPPORTING FLEXIBLE DUCT SHALL IN NO CASE BE LESS THAN 1 1/2 INCHES WIDE. FLEXIBLE DUCT SHALL BE SUPPORTED PER MANUFACTURER'S RECOMMENDED MATERIALS, BUT AT NO GREATER DISTANCE THAN 4 FEET MAX. PERMISSIBLE SAG IS MAX. 1/2 INCHES PER FOOT OF SPACING BETWEEN SUPPORTS. MIN TWO (2) 12 GA SLACK SAFETY WIRES AT DIAGONAL CORNERS. MIN. 6' -0" LINED DUCT WITH ONE CHANGE IN DIRECTION. SEE PLANS FOR DUCT SIZE. PROVIDE TRANSITION AS REQUIRED (TYP.) NOTE: LIMITED TO FANS WEIGHING 50 LBS. OR LESS 6 CEILING EXHAUST FAN INSTALLATION DETAIL FILE: 005805M60.DWG — M60 I EDIT: 11/30/2007 3:35 PM BY MICHAELH I PLOT: 11/30/2007 5:01 PM BY RAY JUACHON CEILING DIFFUSER HANGER STRAP SECURE TO STRUCTURE AS REQ'D LOCATE WITHIN 2 FT. OF DIFFUSER CENTERLINE. SHARP RADIUS NOT ACCETABLE FLEX DUCT, SEE PLAN FOR SIZE PROVIDE SMOOTH RADIUS TO DIFFUSER CONNECTION, PROPERLY SUPPORT FLEX DUCT FOR SMOOTH AIR FLOW PROVIDE 2 ANGLE CLIPS ON OPPOSITE SIDES OF DIFFUSER SCREW TO T —BAR FOR LAY —IN T —BAR CEILING DIFFUSER (T —BAR LAY —IN & SURFACE MOUNTING SHOWN) 2 CEILING SUPPLY CONNECTION NO SCALE SHEET METAL PLENUM GYP.BD. CEILING U.O.N. NO SCALE PERFORATED CEILING GRILL U.O.N. 5 CEILING RETURN DETAIL 1.5x RADIUS FOR SURFACE MOUNTED CEILING DIFFUSER 8"Wx8 "H BOOT OPN'G. AT OPOSITE SIDES I (ED) -o-- 90' OR 45' RADIUS ELBOW 90' MITER ELBOW 90' TAKE —OFF 15' MAX SIZE TRANSITION DUCT DOWN DAMPER COLLAR SESMIC RESTRAINTS BY MECHANICAL CONTR. CONTR. NO SCALE FAN POWERED VAV UNIT (FPB) ANGLE TAKE —OFF 2 RADIUS TAKE —OFF SD) 90' SPLITTER TAKE —OFF )(SD) RADIUS SPLITTER TAKE —OFF CABLE END #2 NO SCALE 1 DUCT DETAIL NO SCALE CHAMBER COLLAR CRIMPED END (TAPED) —\ CLOSED DAMPER POSITION (3 -E) ADJUSTING SHAFT CLEARANCE HOLE NOTES: SPACERS (2 -A) FAN POWERED CAM SUPPORT BRACKET SUPPORT SCREW (2 -B) 90' OR 45' ELBOW 90' TAKE —OFF SIZE TRANSITION NOTES 1. SINGLE —LINE ILLUSTRATIONS ARE SYMBOLS USED ON DRAWINGS 2. SIZE A &B DIMENSIONS IN PROPORTION TO AIR QUANTITIES IN EACH LEG SPLIT 1. ALL SLOT DIFFUSERS LOCATED IN CEILINGS ARE TO BE PROVIDED AND INSTALLED BY CEILING CONTRACTOR (S.A.D.) MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL PLENUM BOX. 60" MINIMUM FLEX CONNECTION NOTE: 1. PROVIDE SEISMIC BRACING AT ALL FAN POWERED BOXES. USE CBC REQUIRED SEISMIC DESIGN CRITERIA. 2. SUBMITTALS FOR SPRING ISOLATORS AND CONNECTION TO STRUCTURE SHALL BE STAMPED AND SIGNED BY A STRUCTURAL ENGINEER. 3. SPRING ISOLATOR SHALL BE MASON INDUSTRIES OR EQUAL 45' TAKE—OFF 90' CONICAL TAKE ---OFF DUCT DOWN SUPPORT CLIP(1 -A) SET SCREW (1 -B) CAM AIR BAR BULB (TYP) GYP. CEILING (SEE ARCH. DWGS.) 4 SLOT WITH INTEGRAL VOLUME DAMPER ATTACH TO STRUCTURE 1/2" THREADED ROD SPRING ISOLATOR (0.5" DEFLECTION) (MIN OF 4 PER UNIT) PROVIDE STRUCTURAL SUPPORT & BRACING AS PER LATEST SMACNA SEISMIC BRACING CRITERIA. 7 VAV TERMINAL BOX SUPPORT DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED JAN - 2 2005 City Of Tukwila BUILDIN . DIVISION LINED DUCT WITH IN. 1/2" LINING. BRANCH DUCTS Mop- z73 WILLIAM DUFF ARCHITECTS 101 Howard Strict. Suite E. Set Francisco. CA 94105 INTERFACE = I � E N G I N E E R I N G Contact MICHAEL HYNDING Project 2007 - 0058.05 214 GRANT AVE., SUITE 450, SAN FRANCISCO, CA 94108 PHONE 415489.7240 FAX 415.489.7289 Issue No. EIRE 11 5 Job Title MAC SOUTHCENTER Job Address 633 SOUTHCENTER PKWY TUKWILLA, WA 98188 Sheet Title MECHANICAL DETAILS Drawn By: Checked By: KM SF Job No. 07025 Scale NONE Sheet No. RECEIVED DEC 12 2007 PERMIT CENTEE, t: 415.371.0900 * 415.371.0800 www.wordt.corr1 Date M6 ,.•;' ?? c ;•••;ns . >N s. irrcn . .. / .. %;,• ... :;h;•L. %r•s . .. .,n•is<< r:;41 • ;x::..,.. ..e , .,., „. :S,.i;arr, (;•":',.71