Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-275 - BOEING #9-08
BOEING #9 -08 9725 EAST MARGINAL WAY S M07 -275 Parcel No.: 0003400018 Address: Suite No: Tenant: Name: Address: Value of Mechanical: $45,000.00 Type of Fire Protection: doc: IMC -10/06 City -f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 9725 EAST MARGINAL WY S TUKW BOEING #9 -08 9725 EAST MARGINAL WAYS , TUKWILA WA Owner: Name: BOEING COMPANY THE Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 Contact Person: Name: JERRY SCOTT, MACDONALD MILLER Address: P 0 BOX 47983 , SEATTLE WA Contractor: Name: MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT EOUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: INSTALL 10 TON CHILLED WATER SOURCE A/C UNIT AND ASSOCIATED PIPING. RELOCATE 8 DIFFUSERS AND 6 RETURN GRILLS AND ASSOCIATED DUCTWORK. RELOCATE 1 EXISTING THERMOSTAT Phone: Phone: 206 -768 -4256 Phone: 206 - 763 -9400 Expiration Date: 12/31/2008 M07 -275 01/04/2008 07/02/2008 Fees Collected: $672.95 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3-15 HP /500,000 BTU 0 15-30 HP/1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M07 -275 Printed: 01 -04 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:: / /www.ci.tukwila.wa.us . thy Permit Number: M07 -275 Issue Date: 01/04/2008 Permit Expires On: 07/02/2008 Date: Oil ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o 4te perfonnance f work. I am authorized to sign and obtain this mechanical permit. i Date: aif Del I [> & This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspendec or abandoned for a period of 180 days from the last inspection. M07 -275 Printed: 01 -04 -2008 Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUICW Suite No: Tenant: BOEING #9 -08 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 6: ** *FIRE DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 -275 Status: ISSUED Applied Date: 12/12/2007 Issue Date: 01/04/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 8: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 9: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 10: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 11: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 14: Local U.L. central station supervision is required. (City Ordinance #2051) 15: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72- 1.3.3) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and doc: Cond -10/06 M07 -275 Printed: 01 -04 -2008 #2051) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17: To schedule all construction fire - related inspections send an e to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M07 -275 Printed: 01-04 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond - 10/06 Date: DI, I ON ! v g M07 -275 Printed: 01 -04 -2008 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 latp://www.citukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: -/ 7 0441260 0,01.- 1 J4`1 S Tenant Name: gnf l tJC& t3 —DO Property Owners Name: 1 Jet—W6 (' ri t PA-N C Mailing Address: 4 aoX 3 70 7 M/S # 1 r' 6 1 Name: j i ( S/oT'> CW«c- L %p)J4t -13 f' 4l1 Lee ) Mailing Address: P' 801( L{ 7' 83 ko -Mail Address: J "-A 1 . Company Name: LgAsl: CRUM LP:IAA S Mailing Address: h7 Contact Person: P?tTfiC K 1 1W'JCFn,J E -Mail Address: Pafri&k . wlciUeRAAQ_)eL 1Sb6 1d S. !Lin Contractor Registration Number: L EASEL. IPA A18 Contact Person: E -Mail Address: Contact Person: E -Mail Address: Q:Upplications\Forms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh Building Peri 'No. 1 2:75" Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 4e)0.7 6 —00 Jg Suite Number: g 136 g'` Floor: 3 New Tenant: ❑ Yes O.No City LA 7S I Z'- State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Day Telephone: 066) 76g L 147 , 5 E'4Trc.e_ c J4 1PP City State t Zip Fax Number: 1 ) 764? -`' 7 Zs GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) SEA - rr - � L) 4 9gicq City State Zip Day Telephone: (Z ) �OSS —lD S3 Fax Number: C b) s 7 c630 Expiration Date: 9/30/08 ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: State Zip City Day Telephone: Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: ,,�,vIailing Address: State Zip City Day Telephone: Fax Number: Page 1 of 6 sldJnit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser Pi 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 1 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 - 50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind MECHANICAL CONTRACTOR INFFORMATION Company Name: M fire- vvn) Oil- i - Ett- FA C.IL / T•1 , itf wT) OA) S , Mailing Address: 7 DETlzv i f 4 ✓, $,, j S674 (7L t-tiA 90/66 City State Zip Contact Person: 3 1✓�P.4 CoTr Day Telephone: (ZOO 7b D C - Z S& MECHANICAL PERMIT INF IATION - 206 -431 -3670 E -Mail Address: ,eYf • SW ++ A 1'i c J t) /ter, CO WL Fax Number: ( z0(9) 7(1? -Li 2 5 - 7 Contractor Registration Number: M kJ'-DO f 5 q 00 Rl.) Expiration Date: I Z/3 1 /0 Valuation of Mechanical work (contractor's bid price): $ '1 S DOt) Scope of Work (please provide detailed information): 1105 10 To h) c1 k,u. j cd4rEg sOa2Gf (PLAwr 11 Ac_ u& r., Nv 46soe ATEA t I LA GE 8 of FF0s4 05 ANO lefEliVi) C' 2tte 4 As5C,c, q 12vcrw &2K RtLocATE. 1 fix /5I 11r/ /1 "7— ST A'f Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... Fuel Type: Electric ❑ Gas .... Other: jLAV1T tM IU.E %) W, T — AAv IO J C.coL[a/4 Indicate type of mechanical work being installed and the quantity below: Q: Applications\Fonns- Applications On Line' -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. '`uwt;.- Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO ZED AGENT: Signature: , �� s. .I _INS wtAc.j 144 u_ l� Date: ti? *-10-Q 7 Print Name: 3ORP( Scarf Mailing Address: { ' 471 63 Date Application Accepted: • (0 Q:Wpplications\Fonns- Applications On Lineu -2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: CEATTG City w 9 ig( State Zip Date Application Expires: Staff Initials: utik Page 6 of 6 Receipt No.: R07 -02749 Payee: MACDONALD MILLER ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 • Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 0003400018 Permit Number: M07 -275 Address: 9725 EAST MARGINAL WY S TUICW Status: PENDING Suite No: Applied Date: 12/12/2007 Applicant: BOEING #9 -08 Issue Date: Initials: WER Payment Date: 12/12/2007 03:02 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 1534 672.95 Account Code Current Pmts 000/322.100 544.36 000/345.830 128.59 Total: $672.95 Payment Amount: $672.95 5942 12/12 9710 TOTAL 672.95 doc: Receiot -06 Printed: 12 -12 -2007 MrNTS: \ D 1 D-O■t/7.1 —\ /0 ---- iWck) e..-EP ...--- Address: 4 112.S F o4i4{ \-- \ 1_13.9?e(4?e-k) (0 17:-f le,ANI-11. -4-e-i--- — Lt a.m. Requester: ‘, I I;Lr -Vivi **0-r- - -+c) c) ce to'14-1 \ i k--\ rteelk 45 Proje(t) ogl vt,) E, q-oei Type of Inspection: i fo.-4 ) \., Address: 4 112.S F o4i4{ Date Called: Special Instructions: Date Wanted: t-08 \ 6- 2...1 a.m. Requester: Phone No: INSPECTION RECORD (Y10-7 Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 El Approved per applicable codes. El Corrections required prior to approval. nsp or: (MAA DV S 0 REINSPECTION FE EQUIRED. Pr" p • at 6300 Southcenter Blvd.. Suite 100. 'Receipt No.: y AA Date: r to inspection, fee must be a ll the schedule reinspection. 'Date: Proj L: Type of Inspection: ‘ 73 • • - 5 : ‘72- Date Called: Special Instructi • ns: r Date Wanted: 2 a. m. Requester: Phone No: \I Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit A407-27 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 6 aZt_ 7; r-t, El Corrections required prior to approval. „dz. $58.00 REINSPECTIO ' EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 1Date: 0 Proje )e- ( �� � % - 0 8 Fire Alarm: Hood & Duct: Type of Inspection: Ve r) -,�- Pre -Fire: Address: c 76 Suite #: C- , wA 5 ,: L Contact Person: tivi# cif eta 1,3 , r � Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT OE 1 - - 2oY 915 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 proved per applicable codes. COMMENTS: 1 7 { 3 - ( A 7 ? � �� ��- P 1 - 1 Corrections required prior to approval. Inspector: Date: I/2 y1 c< Hrs.: /. 4 -f1 sso.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 STANDARD TESTING RECORD FORM Project Name:54Z i j e i3 Project Number: 7 2.7-S3 / 9 Project Location: 6 Pt vorvt. / 1 SEQt/+ aM Test Date: / -1 ' 0 8 Temperature* 72 . Pipe Line /Service Tested Name C.-h /J t) tN4- -E.e_ +6 / a I'. UN IT Location /Description: IN e4 r tN0.-t4 "2bb #. / 1 Piping & materials: Ca epee-- Operating pressure: ' Off' Specification test pressure: /00 Testing Method Method of testing 4-12 / Instrument used 4 ' Q 76 ' Actual test pressure- #/ 0 / PS t Fj Test Results Time test started: 5` °Q A M /- /3 Pressure: / ° : Time test completed: /a .'!GAM / - P-1 " °8 Pressure* / Pi �+ Duration of test: 2 6 i Pressure rise:. a `''C drop. - ° - Signature sn Witness: A /rte CateCe Representing: M 4-4- € ?L Witness: Representing* Witness: Representing' Remarks Job Supervisor's signature M' -(6t.,0 AL L2 .eD © 1986 by MGAA Standard Testing Record Form 110 DEPARTMENTS: �� X2.31' Building Division Public Works Complete Please Route Documents/routing slip.doc 2 -28 -02 HERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M07 -275 DATE: 12 -12 -07 PROJECT NAME: BOEING #9 -08 SITE ADDRESS: 9725 EAST MARGINAL WAY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -18-07 Structural Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESJTHURS ROUTING: Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention Planning Division ❑ Permit Coordinator Not Applicable ❑ No further Review Required n DUE DATE: 01 -15 -08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: SYM A RECORD DRAWING INSTALL HEAT PUMP CR3A6, 5-TON WATER COOLED LIEBERT BUO71WGAGOO UPF IW 460V, 30, 60 2 "HPW GRISWOLD CONTROL VALVE, 2-32 PSID, 1Yz "oL, SET @ 23.3GPM 9PCPPIIRIR3OVQ4 W/ 24" FLEX HOSES MODEL 7486 -10 HP3A4 2 "HPWR 2 "HPWS 3 "H •WR 3 "HPWS HP3D4 PURCHASE /INSTALL AC UNaT RAPTOR SIMULATION LAB 5" RWL DN GRISWOLD CONTROL VALVE, 2 -32 PSID, 1"0, SET @ 10GPM, 2PCPP11R3R2OVCG W/ 24" FLEX HOSE CR3A17, 10 -TON LIEBERT f DH138W ¢" CONDENSATE 1Yz" HPWR 1Yz" HPWS Y" PROCESS WATER REVISION A) J #780312 -00 J #556290 -01 J #160656 -03 BY DW /MJC DMV /RWS M.WONG M.WONG APPROVED KMR /DS EJC MW FOR RWS RWS DATE 10,1.90 03.06.98 04.13.05 10.18.07 SYM 2 "HPWR 2 "HPWS THIRD FLOOR PIPING PLAN SCALE: 1 8 =1 -0 REVISION MATCH LINE (FOR CONTINUATION SEE SHEET 3M62) BY APPROVED DATE LC -1P3D6 \HP3/ ID ID TYPICAL HEAT PUMP SEE NOTE 3 2 "HPWR 2 "HPWS 2" HPWR 2" HPWS 1" ID 2" HPWS 2" HPWR 1" ID 1Y2" ID 1" ID 3 "HPWR 3"1PWS -- e ip v,axcaziww P3E5 —1 4C0 co APPROVED BY 1 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. 6" RWL DN REVISIONS No changes shall be made to the scope of work without prior *,. •val of Tukwila Building Di sion. NOTE: Revisions will require a new plan submittal and may include add itional plan review fees. ' DATE DRAWN F. BABAZADEH CHECKED M. CAUNITIS ENGINEER F. BABAZADEH CHECKED W. HENCKEL APPROVED K. RAMSEY APPROVED a DATE SUBTITLE TITLE BUILDING 9 -08.3 THIRD FLOOR PIPING PLAN -RAL \OT FILE Y Permit No. ® : Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy conditions Is adu owledged: 3 By 2 City of Tukwila BUILDING DIVISION 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2. REDUCE THE TIE -IN FROM 1" TO 3/4" SIZE AND RUN TOWARDS THE HEAT PUMP. PROVIDE SUPPORT AT A MINIMUM OF 8 FT. SPACING. (NO INSULATION REQUIRED) USE FLEXIBLE HOSE SIZE 1/2" - MODEL K10 -2DS -D SUPPLIER - K.J. BARNETT CO. (206) 881-1128 USE COPPER TUBE TYPE "L" FOR SUPPLY & RETURN. TIE-IN CONDENSATE LINE TO EXISTING AS SHOWN. SLOPE AT 1/8" PER FOOT. PROVIDE SUPPORT AND 1" THICK FIBERGLASS INSULATION. DRAIN SHALL COMPLY WITH THE MANUFACTURERS INSTALLATION. USE COPPER TUBE DWV FOR DRAINAGE. NOTE: M E SU THE 1" IT IS A CESSI. FOR ` AINT ANCE. CR3A17, 10 -TON WATER COOLED DOWNFLOW AIR CONDITIONER, LIEBERT DH138W -AGES OPTIONAL AIR FLOW 6,400CFM & EVAP. FAN MOTOR, 2 -WAY VALVE, HUMIDIFIER & REHEAT. CO\STRJCTIO\ RETURN REDLINED COPY BACK TO ENGINEERING WITH ANY DEVIATIONS FROM THE ORIGINAL DESIGN. MOON WONG, 947 -4897, M/C 46 -87 160656 --03, CAPITAL JOB TO INSTALL NEW LEIBERT AIR CONDITIONER INSTALL 10 -TON AIR CONDITIONER AT THE LOCATION SHOWN WITH THE STAND. (THE STAND COMES WITH THE A/C UNIT) INSTALL A CONDENSATE PUMP FOR THE A/C UNIT IF NOT ALREADY INSTALLED. (THE CONDENSATE PUMP COMES WITH THE A/C UNIT). RUN A CONDENSATE DRAIN FROM THE A/C UNIT TO THE EXISTING 1" DRAIN. SLOPE THE PIPING /8 PER FOOT IN THE DIRECTION OF FLOW. PURCHASE AND INSTALL THE HEAT PUMP COOLING WATER SUPPLY AND RETURN PIPING FROM THE 3" MAIN TO THE UNIT. LA> PURCHASE AND INSTALL THE GRISWOLD CONTROL VALVE ON THE HPWS & HPWR UNDER THE RAISED FLOOR WHERE ACCESSIBLE FOR MAINTENANCE, THE GRISWOLD CONTROL VALVE INCLUDES, ISOLATOR -R ON THE RETURN LINE, ISOLATOR -S ON THE SUPPLY LINE, AND 24" S.S. HOSES. >PURCHASE AND INSTALL THE PROCESS WATER FROM THE 1Y" MAIN TO THE A/C UNIT FOR THE HUMIDIFIER. INSULATE THE PROCESS WATER WITH Yz" GLASS FIBER INSULATION, ASTM C547, CLASS 1 MAX K 0.25 AT 50 °F, NONCOMBUSTIBLE, SUITABLE FOR 500 °F AND KRAFT REINFORCED FOIL VAPOR BARRIER W/ SELF - SEALING ADHESIVE JOINT JACKETS.. ALL PIPING (DRAIN, HPWS, HPWR, & PW) BETWEEN THE RAISED FLOOR AND THE REFLECTED CEILING SHALL BE INSULATED WITH 0.5" THICK GLASS FIBER WITH KRAFT REINFORCED FOIL VAPOR BARRIER W/ SELF - SEALING ADHESIVE JOINT JACKETS. INSTALL TWO LIQUI-TECT LEAK DETECTORS ON THE TRUE FLOOR UNDER THE A/C UNIT PER MANUFACTURER INSTRUCTION. (THE SENSORS COME WITH THE A/C UNIT) 8. ALL PIPING SHALL BE HARD DRAWN COPPER TUBING TYPE -L. 9. PURCHASE AND INSTALL PIPE LABELS PER BOEING STANDARD. 10. CONTACT LIEBERT (JAMES SWEET 206 - 763 -5000) TO STARTUP THE UNIT AFTER THE A/C UNIT IS INSTALLED. <EY PLA\ NO SCALE CURRENT REVISION J #160656 -03 SHEET JOB NO. nwn H() OTES Mo14 3M6 SYMBOL viEc o V `-•D C1TV OF' . fl 1K'1VILA I WEC 12 20tql DATE 10.18.07 COMP NO. SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A RECORD DRAWING DW /MJC KMR /DS 10.01.90 B RAPTOR SIMULATION LAB J# 160656 -03 M.WONG RWS 10.18.07 3/4" ID UP 4" RWL DN 41- CO I 7 3/4" ID HP3A7 \1P2/ HP3A8 \1P CO CO CO 3 "HPWR 3 "HPWS HP3A9 \-1P21 4 "HPWR 4 "HPWS 1 1/2" PW HP3B11 1P2 f CO FJP� 3A, P2 P2/ 1" ID 2 1/2 2 1/2 6 "HENS 6 "HP NR 4 "HPWR 4 "HPWS 1 1/2" PW H CO I _ 1Y4 "HPWR Y "H PWS 2" HPWR 2" HPWS 2 "PW UP & DN 1Y "ID ` I ' P ' 3C9 > `-IP 3 / SCALE: 1 8 =1 -0 12" HPWS UP & DN 10" HPWS UP 8" DN 8" HPWR 8" HPWS SEE DETAIL 1 CO CO 1" ID 6" HPWS 6" HPWR P2 MATCH LINE (FOR CONTINUATION SEE SHEET 3M62) THIRD FLOOR PIPING PLAN — B 1 1/2" ID DN TO S. SINK S€E SHE -3M -1-1-1 MATCH LINE (FOR CONTINUATION SFE SHEET 3M60) 1 1/2" ID ' ID CO CO CO 1 1/2" I D 1" ID 1" ID 1" ID 4" HPWS 4" HPWR 3 "HPWR 3 "HPWS `-1 1/2" ID �--1 1/2" ID 1" ID ID 3 "HPWR 3 "HPWS ei 3;; HPWR r 3" HPWS APPROVED BY TYPICAL HEAT PUMP SEE NOTE 3 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. - 4 "RWL DN DATE D' F. BABAZADEH CHECKED M. CAUNITIS ENGINEER F. BABAZADEH CHECKED W. HENCKEL APPROVED K. RAMSEY APPROVED D. SEPTELKA D TE 10.01.90 SUBTITLE TITLE 11111■0111 CO RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 206 -947 -4897, M/C 46-87 160656 -03 CAPITAL JOB TO INSTALL NEW LEIBERT AIR CONDITIONER INSTALL THE PROCESS WATER FROM THE 1Y" MAIN TO THE A/C UNIT FOR THE HUMIDIFIER. INSULATE THE PROCESS WATER WITH //" ARMAFLEX INSULATION. ALL PIPING SHALL BE HARD DRAWN COPPER TUBING TYPE -L. 3. INSTALL PIPE LABELS. G MECHANICAL MASTER COL. A- F/8 -13 LEGEND: p a ,, com ovaoveo 3P� 2. 20 �t otykt o eaDi THIRD FLOOR PIPING PLAN BUILDING 9 -08.3 sTPCT -RA EXISTING WALLS SIC 50 PARTITION L C QT NEW FULL- HEIGHT PARTITION r DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND SIC 45 PARTITION SIC 45 PARTITION DEV. CENTER, WA \OT IS 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. tiO7 2 75 CURRENT REVISION J # 1 60656 -03 SHEET JOB NO. DWG NO. 9 ` �P SYMBOL 3M61 9- 08.3 -3M61 DATE COMP NO. 10.18.07 203CFM 8 "0 TITUS TMS W/ OPPOSED BLADE DAMPER (TYP. OF 4) SYM A B C 200CFM 8 9 x8" NECK 3 -WAY TITUS MCD (TYP. OF 2) 200CFM 8 "x8" NECK 3-WAY TITUS MCD (TYP. OF 2) 200CFM 8 "x8" NECK 4 -WAY TITUS CD (TYP r F 4) 1040 Il�,i- ' 200 C � ,pM� p ; laWfallimill -- 8 » ilifi ' I ■ I i I1PJ . 47 . %Ir -. M a. '!■ iii :isli► ►1 r ., iqui4m 475 !! .�'�i!I�w Vf'sV ! . MI �I' 6 k '414111 ► I IP3B8 47 4 i" 7 err ' iii? l ii _EliMall SWIM. wain 1 ii ' M// @k ill ,OB lin amare i aim a rywo Etatra II rya rir isr w II IIMIKRIEV UMW • Ii�►._Ji CD 6 '� "! II lr 00 ►� - �I = CD CD\ IMBF v _r r Mir c® 'ME _ Or ©plo! l _04 M: �i 3A1 Ia n a minim" _ CD ■ p Willi, Nam; ENE 1 .1 dml wirsid i pis ■ IMII � I� LIM/ 354 r RECORD DWG MODIFY ROOM 32C12 RAPTOR SIMULATION LAB REVISION J11794526 -00 J #160656 -00 BY MJC CH M.WONG APPROVED DATE KMR /RB 3.3.92 02,08.00 RWS 10.18.07 SYM 24/16 ----AESD REVISION MATCH LINE (FOR CONTINUATION SEE SHEET 3M13) 10/8 12/6 MATCH LINE (FOR CONTINUATION SEE SHEET 3M14 THIRD FLOOR HVAC PLAN - B BY APPROVE() DATE 24/16 e) LAWAEZAW ® APPROVED BY DEPT. < ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DATE PRAWN M. CAUNITIS CHECKED R. MURRAY ETIOTTEER M CAUNITIS CHECKED W HENCKEL APPROVED K RAMSEY --- APPROVED DATE 0 SUBTITLE TITLE GENHAL \IOTES: I. TYPICAL HEAT PUMP NUMBERING SYSTEM: e.---EQUIPMENT NUMBER FOR MAINTENANCE (S4 LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2. I\ SYMBOL FOR _RI TYPICAL. 3. FOR TYPICAL HEAT PUMP INSTALLATION SEE DETAIL TYP M521 4. DUCTWORK SWAY BRACING NO. '18 GA. DUCTILE WIRE. MINIMUM ONE BRACE PER DUCT BRANCH. MAXIMUM SPACING 40 FEET. SECURE PENETRATION. SEE DETAIL F3 SECURE PENETRATION. SEE DETAIL TYP M527 BOAT NOTE SYMBOL SHOWN ON SECURE SIDE. CO \STRUCTIO\ RETURN REDLINED COPY BACK TO ENGINEERING WITH ANY DEVIATIONS FROM THE ORIGINAL DESIGN. MOON WONG, 947 -4897, M/C 46-87 160656 -00 EXPENSE JOB TO MODIFY THE EXISTING HVAC SYSTEM MODIFY THE DUCTWORK TO ACCOMMODATE THE NEW DIFFUSER LOCATIONS. FABRICATE AND INSTALL FOUR VOLUME DAMPERS. INSULATE THE DUCTWORK WITH DUCT WRAP. 2` PURCHASE AND REPLACE FOUR AIR DIFFUSERS, TWO WITH 3 -WAY AND TWO WITH 4 -WAY AIR DIFFUSERS. PURCHASE AND INSTALL FOUR AIR DIFFUSERS, TWO WITH 3 -WAY AND TWO WITH 4 -WAY AIR DIFFUSERS. 3:I RELOCATE SIX EGGCRATE RETURN AIR GRILLES. RELOCATE THE HEAT PUMP AIR CONDITIONER'S T'STAT TO THE EAST AS SHOWN. REMOVE THE RETURN DUCT BACK TO THE HEAT PUMP, LEAVING THE OPENING FOR THE AIR RETURN. 7. BALANCE AIRFLOWS AS SHOWN ON THE DRAWING. 8. THE FABRICATION AND INSTALLATION OF THE DUCTWORK SHALL CONFORM TO SMACNA STANDARD. EG 4 KEY PLA\ NO SCALE THIRD FLOOR HVAC PLAN BUILDING 9 -08.3 COTES: SECTION 1/8-.1 L LOCATE TO CLEAR DIAGONAL BRACING =C_ DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION SIC 50 PARTITION \ REVIEWED 1=(3K I: CODE COMPLIANCE APP WED JAN - 2 7.n +1 C ity Of Tukwila 3UILfl, 2.2.21,' tC , EXISTING WALLS NEW FULL - HEIGHT PARTITION A 3M11 CURRENT REVISION J #160656 -00 SHEET OB NO. SYMBOL 3M11 794526 -00 3RD FLOOR DATE COMP NO. \tEc MO7 10.18.07 /91186 SPRI\ 'L =RS SYM. SPRINKLER TYPE TEMP QTY 0 RELIABLE MOD '0' BRASS 1/2" 165'F 8 0 RELIABLE MOD 'G' CHROME RECESSED 1/2" 165E 172 TOTAL 180 SYM A B C D E RECORD DRAWING F -22 PVI MOVE MODIFY ROOM 32C12 PROVIDE SPACE AND MODIFY AREA RAPTOR SIMULATION LAB III i -.Q rd: ...,,,..m....,FA ' -.am , lin .21111111M 61.1.11111 1111 :MOO i A N uIlu... i � = 1 . � ; X15 i !!�� r MPS 1� r '1, Ell nu litim r 2 iffaii; til 0 li, 1 I 44# "! Ti iif/ ri ..a 0=1 if/a � ' IT , Far p+I iC= MIN l�+�'L'�iCn — m „, im 1 I. " I ip _au 2, am fit II�'�wl I vfil wpm E�"r� p _ 1 i I�Ti� _ n � i 1 tl ■ ��� ■�llr�r_+lrv�■r..r.►�..,. , ®�. REVISION 160066 -00 794526 -00 1000979593 J #160656 -00 BY GMM GMM RWS M.WONG APPROVED RWS RWS DATE 03.03.92 05.09.96 03.22.00 11.20.03 10.18.07 SYM REVISION 3RD FLOOR PLA\ SCALE: 1/8 " =1 -0 BY APPROVED DATE _. DRAWN DATE _ SUBTITLE ACCEPTABILITY Q ' - THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE CHECKED FNGlNEER CHECKED APPROVED APPanvr'n TITLE BUILDING 9 -08.3 RETURN REDLINED PRINT SHOWING ANY DEVIATION FROM THE ORIGINAL DESIGN. MOON WONG, 947 -4897, M/C 46 -87 J1160656-00 EXPENSE JOB TO MODIFY FIRE SPRINKLER SYSTE PURCHASE AND INSTALL TWO NEW PENDENT FIRE SPRINKLER HEADS. 2. FABRICATION AND INSTALLATION OF THE FIRE PROTECTION PIPING SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN NFPA CHAP. 13 AND FM CHAP. 2, SECTION 8. JOINT COMPOUND OR TAPE (NOT BOTH) SHALL BE APPLIED ONLY TO MALE THREADS. 3. NOTIFY BOEING FIRE DEPARTMENT 24 HOURS IN ADVANCE OF DOING WORK (206)655 -7700. USE NEW FIRE SPRINKLER HEAD, 155E RATED, VIKING MICROMATIC MODEL "M ", 1 /2 "NPT, 1/2" ORIFICE, 5.6 K- FACTOR PENDANT HEAD, BRASS. THE SHUT-OFF VALVE UV908 -3A IS LOCATED AT COL. C /3. 2:7 s FIRE PROTECTION 3RD FLOOR PLAN L C7 RAL SPRINKLER HEAD , PENDENT IN LINE SPRINKLER HEAD, UPRIGHT DRY PENDANT SPRINKLER HEAD AUTOMATIC SPRINKLER RISER HALON SYSTEM AUTOMATIC DISCHARGE STATION SPRINKLER HEAD, SIDEWALL, UPRIGHT WATER MOTOR GONG PIPE HANGER 2 —WAY EARTHQUAKE BRACE 4 —WAY EARTHQUAKE BRACE VALVE & PIPE CAP OTES 1. NOTIFY BOEING FIRE DEPT. 24 HRS. PRIOR TO SYSTEM SHUTDOWN. 2. SPRINKLER ALAM VALVES: NUMBER: SV 908 — LOCATION: 9- --08.1, COLUMN F/7 3. EARTHQAKE BRACING, FLATTEN & DRILL PIPE ENDS FOR MOUNTING. USE 1"66 SCH. 40 FOR BRACES TO 7' —O" LONG USE 1 1/4 SCH. 40 FOR BRACES 7'-1" TO MAX. 9' -0" LONG. 4. USE 1/2" 155' SEMI — RECESSED SPRINKLER HEADS UNLESS OTHERWISE NOTED. 5. SLOPE ALL PIPING AS INDICATED TO DRAIN BACK TO RISER OR TO LOW POINT DRAIN. 6. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO NFPA PAMPHLET 13 FOR ORDINARY HAZARD OCCUPANCY. 7. HYDROSTATIC TEST TO 200 PSI FOR (2) HOURS SHALL BE WITNESSED AND APPROVED BY THE BOEING FIRE DEEPT. CO ELEVATIONS ARE IN FEET & INCHES ABOVE FINISHED FLOOR. STR„CT JOB NO. \ CURRENT REVISION J #160656 -00 SHEET OT KEY PLAN SCALE: NONE SYMBOL 3M261 Is DATE COMP NO. crCVA : � bEU nat \ 10.18.07 co