Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M07-280 - WESTFIELD SOUTHCENTER MALL - DELIAS
DELIAS 2606 SOUTHCENTER MALL M07 -280 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: AIR MOTION INC Address: 5624 128 ST E , PUYALLUP WA Contractor License No: AIRMOI*077PM DESCRIPTION OF WORK: MECHANICAL FOR T1: (2) NEW VAV BOXES, NEW DUCTWORK, DIFFUSERS, AND CONTROLS. RESTROOM EXHAUST FAN. Value of Mechanical: $17,500.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2606 SOUTHCENTER MALL TUKW DELTAS 2606 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA TIM SCHENK 1120 E 80 ST, STE 211 , BLOOMINGTON MN MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 2 0 0 1 0 0 0 0 * *continued on next page ** M07 -280 Permit Number: M07 -280 Issue Date: 05/08/2008 Permit Expires On: 11/04/2008 Phone: Phone: 800 541 -0821 Phone: 253 - 405 -6206 Expiration Date: 10/23/2009 Fees Collected: $361.78 International Mechanical Code Edition: 2006 Boiler Compressor: 0 - 3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 - HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 13 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 05-08 -2008 The granting of this per= construction or the Signature: I Print Name: � ��-�/ doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M07 -280 Issue Date: 05/08/2008 Permit Expires On: 11/04/2008 Permit Center Authorized Signature: [,),- Date: .5 43 o 6 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. of presume to give authority to violate or cancel the provisions of any other state or local laws regulatinc of wor am authorized to si• and obtain this mechanical permit. Date: -/ P9 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspender or abandoned for a period of 180 days from the last inspection. M07 -280 Printed: 05-08 -2008 Parcel No.: 6364200010 Address: 2606 SOUTHCENTER MALL TUKW Suite No: Tenant: DELTAS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M07 - 280 Status: ISSUED Applied Date: 12/18/2007 Issue Date: 05/08/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: ** *FIRE DEPARTMENT COND1TiONS * ** 7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 8: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 9: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air-moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 10: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 11: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 12: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 14: An electrical permit from the City of Tukwila Building Department Permit Center (206 - 431 -3670) is required for this project. 15: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) doc: Cond -10/06 M07 -280 Printed: 05-08 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila (206)575 -4407. * *continued on next page ** doc: Cond - 10/06 M07 - 280 does not imply approval of Fire Prevention Bureau at Printed: 05-08 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the perfo �;yj� ork. Signature: Print Name: �a�t - icl� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http.• / /www.ci.tukwila.wa.us Date: V://6 doc: Cond -10/06 M07 -280 Printed: 05 - 2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tukwi la. wa. us SITE LOCATION L, Site Address. 5Ouf13CE tL ( Tenant Name: DE LL AS Property Owners Name: W ESTFIELO C RPOMTLOr4 s 1 . Mailing Address: 1(601 W I LS 1A 1(l1a QI.YO SV 1t'E 1100 , LOS ActCEUC CA S002S City State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: -rim S C r E r d 4 ,4 I avert ibrieS Day Telephone: 1 • $OD • StA I.0' Z 1 Mailing Address: ►►ZO E • Q,O SC. SV 1 fE zit, (MACH IN(pro-4 Mr( S Zip E -Mail Address..+ ms a ci ee jores.CO�. GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: T. 13.0 . Mailing Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** City Contact Person: Day Telephone: E -Mail Address: Fax Number: Expiration Date: Contractor Registration Number: ARCHITECT OF RECORD — All plans oust be wet stamped by Architect of Record Company Name: 514 t€11S 14OC.(C. AnC44 t MGM 11W. Project No. Building Permit No. Mechanical Permit No. , Plumbing/Gas Permit No. 1 Public Works Permit No. 01 1 (For office use only) King Co Assessor's Tax No.: V ` 001 Suite Number: ZI OC3 Floor: Z NO New Tenant: Yes ❑ ..No State City Fax Number: QSZ • %SA •'AQ State Mailing Address: 6110 s. SVNQJiVI 14ES teitoi1CllA.S 014 x•1308 City State Day Telephone: 6 • SAS• 4SSv Contact Person: REGEc.GA Oriel E -Mail Address: r'0 leyeA nertISV10Ck.C.OA Fax Number: 614 • sir. l t Contact Person: a.eC C.€ 7LAn tL• Q:1ApplicationsWonns- Applications On Line \3.2006 - Permit Application.doc Revised: 9 -2006 bh E -Mail Address: 1r• frc4 .e. e.. S4letre em od • La" Zip Zip Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: S I4 ° !`1 J - Erice ' L 1 t<C. 00. 430 %1 City State Zip Day Telephone: 614 • Cqr • 4 5'•SO Fax Number: 61'( • 54S' • 1 SS Page 1 of 6 BUILDING PERMIT'INFORON - 206 -431 -3670 Valuation of Project (contractor's bid price): $ Z00 Existing Building Valuation: $ Scope of Work (please provide detailed information): 9u$(O Or* CIa ries M1r41Sc4r' C gO I,1 nits lenaL Provide All Building Areas in Square Footage Below Floors thru Basement Accessory Stricture* Attached Garage WM Interior Remodel Addition to Existing Structure rew 111- SiMi MEW MEM =VA 11111WRINIII 1■7111 MIMI IIAIIMIll ii �� Typ of Construction per IBC 11 -f3 Type of Occupancy per IBC . Will there be new rack storage? a....Yes 1 Floor 2 n. 3 Floor Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (are • f the foundation of all structures, plus any decks over 18 in • ' es and overhangs greater than 18 inches) *For an Accessory dwelling, prov e the following: Lot Area (sq ft): Floor area of principal dwelling: oor area of accessory dwelling: *Provide documentati. that shows that the principal owner lives in one of the dwellings as his or er primary residence. Number of Parking Stalls P . vided: Standard: Compact: Will there be a change in e? ❑ Yes B No If "yes ", explain: FIRE PROTECTI ' /HAZARDOUS MATERIALS: Spn ers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Floor ❑.. No If yes, a separate permit and plan s mittal will be required. Handicap: Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser / 2 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 1 Thermostat 1 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM •z/ Incinerator — Comm/Ind MECHANICAL PERMIT INFdMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: 7:11.0. Mailing Address: Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... ❑ Q:\Applications\Fonns- Applications On Line \3-2006 - Permit Appliation.doc Revised: 9 -2006 bh City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 7 ( Scope of Work (please provide detailed information): 2 — New 'i 4 2OXF.5 1 N61-1 QYGf Wo(UC• Q%FFVf(YLS MO cor(t'[tokS aeXETICIan EXIA N FAA • Fuel Type: Electric is Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Page 4 of 6 PUBLIC WORKS PERMIT INFORMATION 206- 433 - 0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water Availability Provide . Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate w ❑ ...Water District #125 Submitted with Application (mark boxes whic ❑ ...Civil Plans (Maximum Paper Size — 22" x 3 ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Eas Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ .. Aban > > Septic Tank ❑ ...Cap or Remove Utilities ❑ .. Cur. ut ❑ ...Frontage Improvements ❑ .. P. -ment Cut ❑ ...Traffic Control ❑ .. • oped Fire Line ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Wate ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension ..Public ❑ ...Water Main Extension Public FINANCE INFORMATI Fire Line Size at Pro • rty Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing Name: Mailing Address: cubic yards cubic yards Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Applieation.doc Revised: 9 -2006 bh Call before you Dig: 1-800-424-5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. It ❑ .. Highline ❑... alVue ❑ .. Renton er Availability Provided Septic System: ❑ On -site Septic System — For on -site septi • ystem, provide 2 copies of a current septic design approv • • y King County Health Department. ❑ .. Geotechnical R ent(s) ❑ .. Maintenance .. Work in Flood Zone Storm Drainage WO # WO # WO # ❑...Ded t Water Meter Size Private Private Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment ❑ .. Renton ❑ .. Seattle ❑...Traffic Impact Analysis reement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Ri -of -way Use - Profit for less than 72 hours ght -of -way Use — Potential Disturbance City City ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding Day Telephone: State. Zip Day Telephone: State Zip Page 3 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZEDTO APPLY FOR THIS PERMIT. 4 BUILDING OWNER OR A H RIZED AGENT: Signature: Print Name: 'TIM SGIA tG Mailing Address: 1120 €. Bo it sra Sv 1 rC .24% , (Room x&rver , mt.( s rl Z 0 City Date Application Expires: dill Islet Date Application Accepted: 1-lial0 Q:1Applications\Fo!ms- Applications On Line 13 -2006 - Permit Application.doc Revised: 9 -2006 bit Date: 11/2401 Day Telephone: 1.800• s I • Deli State Zip Staff Initials:� Page 6 of 6 Fixture Type: Qty ! Fixture Type: ty :% F' : re Type: Qty ; Fixture Type: " Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) i 1 sh fountain . Gas piping outlets - Bidet Food -waste grinder, commercial Receptor, indirect aste Clothes washer, domestic Floor drain Dental unit, cuspidor Shower, single head trap Un is Dishwasher, domestic, with independent drain Lavatory Z Wat loset Building sewer or trailer sewer Rain water system — p- drain (inside buildin Water h er and/or vent 1 Additional medical gas inlets /outlets — six or more park Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteratio • f water piping and/or w • r treating equipment Repair or a tion of drainage o ent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plumbing work (c • tractor's bid price): $ Valuation of Gas Piping work (c « tractor's bid price): $ Scope of Work (please provide de led information): / StAkWif Oft/ 0 1 TWO NEB/ .174t L SS A _ Walg. 1V 1.4 o = Mel 4- I Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Indicate t ype of plumbing fixtures and/or gas piping outlet Q:\Applications\Forms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh eing installed Sew City State Zip Day Telephone: Fax Number: Expiration Date: d the quantity below: tLOG I / ..t A Page 5 of 6 Parcel No.: 6364200010 Permit Number: M07 -280 Address: 2606 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/18/2007 Applicant: DELTAS Issue Date: Receipt No.: R08 -01526 Initials: WER Payment Date: 05/08/2008 09:24 AM User ID: 1655 Balance: 80.00 Payee: AIR MOTION INC rinr. Rarwint -(16 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Met hod Descriptio Amount Payment Check 20042 295.42 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES RECEIPT Account Code Current Pmts 000/322.100 295.42 Total: $295.42 Payment Amount: $295.42 2153 05/08 9711 TOTAL 295.42 Printati• 05- 0R -20fR RECEIPT NO: R07 -02796 Initials: User ID: iEM 1165 Payee: ELDER -JONES SET ID: S000000921 SET NAME: T set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http: //www.ci.tukwila.wa.us D07 -466 1,251.89 EL07 -790 94.30 M07 -280 66.36 PG07 -340 39.50 TOTAL: 1,452.05 TRANSACTION LIST: Type Method Description Amount Payment Check 50447 ACCOUNT ITEM LIST: ' Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Payment Date: 12/18/2007 Total Payment: 1,452.05 1,452.05 1,452.05 Account Code Current Pmts 000.345.832.00.0 94.30 000/345.830 1,357.75 TOTAL: 1,452.05 6258 12/19 9710 TOTAL 1452.05 r- Proje c I C J Type of Inspection: l Address: _- Coo ( vii A ( t Date Called: Special Instructions: Date Wanted: 7 —1H0 rtf , Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION Vt. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector 1Date: INSPECTION RECORD Retain a copy with permit ni 0 PERMIT NO. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: Date: COMMENTS: \14N - 1 Re 4 0 ..lL< 55 YI 0 • Zf - ?sSod cre ry-CS LA r i.t. LAG 2 IF \ IAN • 2 ep4-....4,1/4 Ad Y{ 55 A o • Z-3 - P0 . c , li e s rAv% i -E- L44- 21 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: j7`liac Address: Special Instructions: Type of Inspection: (1 e Date Called: Date Wanted: 11 16 a.m. p.m. Requester: Phone No: Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit poi - U Corrections required prior to approval. Date: 7(7/Or n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 1Date: Project: Type of Inspectign: T Address: t Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: I»1a7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tt- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 367 El Approved per applicable codes. J Corrections required prior to approval. COMMENTS: Y" /o �K -C or (•Pt,ivi'7 Ifucr /He/allot I/I& 10-5/0 l/ Inspector:/ INSPECTION NO. 0.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit ( Date: / f` or Proj • >! (AS Type Inspection* i 1 N.\ A dress: ( G r t Date Called: Special Instructions: Date Wanted: a.m. Z I -O� Requester: Phone Nini :7'5 LJ 8 7P? INSPECTION RECORD Retain a copy with permit ` I PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- El Approved per applicable codes. D Corrections required prior to approval. 13 COMMENTS: F /4 oil -I r J4/5 INSPECTION NO. $58.0DINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: ACTIVITY NUMBER: M07 -280 DATE: 12 -18 -07 PROJECT NAME: DELIAS SITE ADDRESS: 2606 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: BuPidin 'vision Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 �--� PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP DETERMINAT19N OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: q(A/lky, 5 1 Fire Prevention Structural Incomplete TUES/THURS ROU ING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: DATE: Planning Division Permit Coordinator n C DUE DATE: 12-20-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: C DUE DATE: 01-1 7-08 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License AIRMOI *077PM Licensee Name AIR MOTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601495387 Ind. Ins. Account Id Business Type CORPORATION Address 1 5624 128TH ST E Address 2 City PUYALLUP County PIERCE State WA Zip 98373 Phone 2537708270 Status ACTIVE Specialty 1 HTGNENT /AIR CONDITIONING Specialty 2 UNUSED Effective Date 10/14/1993 Expiration Date 10/23/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date VERT, LYNN V 01/01/1980 DOWNS, WILLIAM R 01/01/1980 VERT, LYNN V AGENT 01/01/1980 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information No Matching Information Savings Information I Bank I Assignment https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= AIRMOI *077PM 05/08/2008 6 " UP N I1 N -SALE (TYP.) 2 )._/64,0Vfeia CFM RG -2 FR MEDIUM PRESSURE DUCT. MO2.0 F=R RG -2 O • O • FR ALCOVE MEDIUM PRESSURE TAP AND DUCT. SD -1 530 1249 12" it 0 0 I8 "x14" SYMBOLS & ABBREVIATIONS LEGEND © THERMOSTAT Q SENSOR ® ANNUNCIATOR DUCT SMOKE DETECTOR C� DUCT OFFSET SUPPLY DUCT - UP SUPPLY DUCT - DN RA OR EXH. DUCT UP RA OR EXH. DUCT DN ELBOW TURNING VANES FIRE DAMPER (F.D.) MANUAL BALANCE DAMPER TRANSITION 1 ►1 ><1 11' ■ • X "(1) AB. A/C AD. AFF. AI-IU_ ARCH. BED. B EL. BLDG. EGRESS CORRIDO TYP. ) MANUAL VOLUME DAMPER (TYP.) SUPPLY DIFFUSER LINEAR DIFFUSER RETURN GRILLE EXHAUST GRILLE SPIN -IN FITTING SPIN -IN FITTING W/ MAN. BAL. DPR. CONNECT TD EXISTING UPRIGHT SPRINKLER HEAD CONCEALED SPRINKLER HEAD ROUND DUCT ABOVE AIR CONDITIONING ACCESS DOOR ABOVE FINISHED FLOOR AIR HANDLING UNIT ARCHITECT BACKDRAFT DPR. BELOW' BUILDING CFM. CLG. CONT. CONTR. COORD. CUH. DIFF. DISC. DN. DPR. EA. EBBH EC. EX. EXI. F. DPR. FLEX. PLR. GC. HC. 1-IP. MAX. MCA. MECH. MFR. MIN. MOCP. MTD. NTS. OA. PG. RA. RTU. SA. TV. TYP. NH. W/ ( 6 ) EX.10 " EXI-I I - Ir � CUBIC FEET PER MINUTE CEILING CONTINUATION CONTRACTOR COORDINATE CABINET UNIT HEATER DIFFUSER DISCONNECT DOWN DAMPER EACH ELECTRIC BASEBOARD HEATER ELECTRI CAL CONTRACTOR EXISTING EXHAUST FI RE DAMPER FLEXIBLE FLOOR GENERAL CONTRACTOR HEATING CONTRACTOR HORSEPOWER MAXIMUM MAX CIRCIUT AMPAC I TY MECHANICAL MANUFACTURER MINIMUM MAX QVERCURRENT PROTECTION MOUNTED NOT TO SCALE OUTSIDE AIR PLUMBING CONTRACTOR RETURN AIR ROOFTOP UNIT SUPPLY AIR TURNING VANES TYPICAL WATER HEATER WITH T 1 1 6 ) EX.30 "x2� MALL 5A ( 1 ) ( 3 ) ( 4 ) ( 5 ) 0 AND LOCATION. 0 1 6 EX.22 "x20" MALL 5A ( 6 ) PROVIDE NEW MEDIUM PRESSURE 22 "x20" SQUARE TO 16 "0 ROUND. FLEX 0 ( q ) RG -1 CONNECTION (TYP. ) GENERAL CONTRACTOR 51-1ALL INSTALL AN ADJUSTABLE SENSOR AS FURNISHED BY DELIA'S WITH CLEAR LOCKING COVER. SENSOR SHALL BE COMPATABLE WITH VAV BOXES AND SHALL INCLUDE TWO -STAGE HEAT CONTROL AND AIR VALVE COOLING CONTROL CAPABILITIES. GENERAL CONTRACTOR TO FURNISH AND INSTALL 18 GA. CONTROL WIRING BETWEEN VAV AND SENSOR. GENERAL CONTRACTOR SHALL PROVIDE ALL MANUALS AND INSTRUCTIONS TO THE STORE MANAGER (INSTRUCT THE STORE MANAGER ON OPERATION UPON TURNOVER) AND THE PROJECT MANAGER (FOR THE CLOSEOUT PACKAGE). REFER TO SPECIFICATIONS FOR MORE INFORMATION. VAV -1 AND VAV -2: GENERAL CONTRACTOR SHALL INSTALL A PARALLEL FAN- POWERED VARIABLE AIR VOLUME BOX W ITH TWO -STAGE ELECTRIC HEAT, FIELD INSTALLED SOUND ATTENUATOR AND ALL ASSOCIATED ACCESSORIES AS FURNISHED BY DELIA'S AND AS INDICATED. MAINTAIN REQUIRED CLEARANCES. GENERAL CONTRACTOR SHALL PROVIDE LANDLORD CONTROL TIE -IN PER LANDLORD'S REQUIREMENTS. FIELD VERIFY AND COORDINATE REQUIREMENTS PRIOR TO SID AND INCLUDE THE COST OF T1415 WORK IN SID. REFER TO VAV SOX SCI- IEDULE ON SHEET M2.0 FOR ADDITIONAL REQUIREMENTS. CONTRACTOR. MUST VERIFY MODEL NUMBERS AND ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION. REFER TO SPECIFICATIONS FOR MORE INFORMATION. EF -1: GENERAL CONTRACTOR TO INSTALL NEW EXHAUST FAN AS SCHEDULED AND AS FURNISHED BY DELIA'S. INSTALL AND SECURE PER MANUFACTURER'S INSTRUCTIONS. EXTEND TO LANDLORD'S EXISTING EXHAUST MAIN. FIELD VERIFY LOCATION, SIZE AND OTHER REQUIREMENTS OF LANDLORD'S EXISTING EXHAUST MAIN PRIOR TO BID. SEE EXHAUST FAN SCHEDULE ON S4-ABET M2.0 FOR FURTHER INFORMATION. GENERAL CONTRACTOR SHALL PROVIDE NEW MEDIUM PRESSURE SPIRAL DUCT AND TAP UPSTREAM OF VAV SOX AS INDICATED AND PER LANDLORD REQUIREMENTS. EXTEND A MINIMUM OF FIVE (5) TIMES THE DIAMETER OF SUPPLY DUCT STRAIGHT (NO OFFSETS, BENDS, ELBOWS OR OTHER ACCESSORIES) AND CONNECT TO INLET SIDE OF VAV UNIT WITH ONE FOOT OF FLEX DUCT. OUTLET CONECTION SHALL BE FULL. SIZE OF VAV UNIT DISCHARGE 1 IT1 -I FLEX CONNECTION, PROVIDE TRANSITION AS REQUIRED. FIELD VERIFY AND COORDINATE SIZE, LOCATION AND ALL REQUIREMENTS PRIOR TO SID AND INCLUDE COST IN SID. SPRINKLER HEADS SHOWN FOR REFERENCE ONLY. CONTRACTOR TO DETERMINE ACTUAL AMOUNT AND LOCATION OF HEADS. REFER TO SPECIFICATIONS FOR HEAD TYPES. COORDINATE REQUIREMENTS WITH LANDLORD AND DELIA'S_ EXISTING MALL DUCTWORK TO REMAIN. FIELD VERIFY EXACT SIZE EX.6 "4 EX1-1 MECHANICAL CODED NOTES ( 7 ) ( 8 ) ( ) f • 0 0 -- PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection 6 SALES • (TYP.) 12 "4) 0 0 1 2 2 6 "<p MECHANICAL FLOOR PLAN = 1 ' - - 0 " SCALE: 1/4" ' _O" AIR DEVICE LOCATED IN LONER DRYWALL CEILING BELOW PLATFORM. RUN SHEETMETAL DUCT FROM DEVICE IN LOWER CEILING THROUGH JOIST SPACE AND UP TIGHT TO WALL ABOVE PLATFORM. COORDINATE VERTICAL DUCT WITH PLATFORM ACCESS. GENERAL CONTRACTOR SHALL MAINTAIN EXISTING RETURN AIR PATI -I THROUGH DEMISING WALLS. HOLD DRYWALL DOWN 6" BELOW DECK AT ALL COMMON DEMISING WALL LOCATIONS AS REQUIRED BY LANDLORD. COORDINATE REQUIREMENTS WITH EXISTING CONDITIONS AND MALL OPERATIONS MANAGER. PROVIDE 1/2 "xl /2" WIRE MESH SCREEN ALL ALONG DEMISING WALL OPENING. FIELD VERIFY AND COORDINATE ALL REQUIREMENTS WITH LANDLORD PRIOR TO BID AND INCLUDE ALL COSTS OF THIS WORK IN SID. RETURN AIR GRILLE TO BE USED FOR ACCESS TO EQUIPMENT LOCATED ABOVE THE CEILING. GENERAL CONTRACTOR SHALL ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3' -0" VERTICALLY AND 2' -0" HORIZONTALLY IN ALL DIRECTIONS AROUND EQUIPMENT 15 MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. IF THIS FREE AREA GAN NOT BE OBTAINI^D CONTACT DELIA'S CONSTRUCTION MANAGER. LOCATE EQUIPMENT TO ALLOW ACCESS FOR MAINTENANCE, REPAIR AND REPLACEMENT OF ALL COMPONENTS FROM GRILLE. • SD -1 530 • SD -2 50 a 12") • REVIEWED APPROVE COMPLIANCE R JAN - 21M City Of Tul wily B ILDING DIVISION 124) 0 SEPARATE PERMIT REQUIRED FOR: 0 Mechanical s4 Electrical St Plumbing jGas Piping City of Tukwila BUILDING DIVISION 0 - &, SD -1 530 • Q (TYP. ) 7. BALANCE SYSTEMS TO CFM'S NOTED ON PLANS. 0 0 TYP.) SD--1 530 2. GENERAL CONTRACTOR IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND 15 RESPONSIBLE TO COORDINATE AND SCHEDULE ALL WORK WITH AND BETWEEN ALL SUBCONTRACTORS AND TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. FURTHERMORE, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY AND COORDINATE WORK BETWEEN ALL TRADES, LANDLORD REQUIREMENTS, CEILING HEIGHTS AND EXISTING CONDITIONS PRIOR START OF WORK OR ORDERING OF EQUIPMENT. 3. GENERAL CONTRACTOR SHALL VISIT JOB SITE AND BE FAMILIAR WITH LANDLORD'S REQUIREMENTS AND EXISTING CONDITIONS. NO ALLOWANCE WILL BE MADE FOR EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND /OR FAILURE TO PREDETERMINE ALL REQUIREMENTS IMPOSED BY THE LANDLORD, EXISTING CONDITIONS OR OTHER AUTHORITIES. 4. DUCT DIMENSIONS ARE NOMINAL CLEAR INSIDE DIMENSIONS. DUCT LAYOUTS ARE SCHEMATIC. FIELD COORDINATE ALL DUCT RUNS. (PRIOR TO DUCT FABRICATION) NO EXTRAS SHALL BE AWARDED FOR DUCT REVISIONS CAUSED BY LACK OF COORDINATION. 5. VERIFY ALL CONDITIONS IN FIELD PRIOR TO BID. REFER TO RESPONSIBILITY SCHEDULE ON SHEET M2.0 FOR MORE INFORMATION. 6. ALIGNMENT /PLACEMENT OF HVAC DEVICES 15 CRITICAL. COORDINATE ALIGNMENT WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND LIGHTING PLAN. B. GENERAL CONTRACTOR IS TO PROVIDE AND INSTALL FIRE -RATED PIPE SLEEVES AND SEALS ON ALL PIPING THAT PENETRATES A FIRE -RATED PARTITION. q. SPIN -IN FITTINGS WITHOUT MANUAL BALANCING DAMPERS TO SE USED FOR ALL ROUND BRANCH TAPS ABOVE INACCESSIBLE DRYWALL CEILINGS WITH BALANCING REQUIRED WITHIN 2 FT. OF DIFFUSER WITH PLASTER FRAME. FLEX DUCT AT AIR OUTLETS TO BE MAX. 5' -0" LONG AND INSULATED. 10. ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED SHALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR AT GENERAL CONTRACTOR'S EXPENSE. COORDINATE ROOF PENETRATIONS WITH LANDLORD'S REPRESENTATIVE. 1. ALL HVAC WORK (MATERIALS, FABRICATION, INSTALLATION, ETC.) SHALL COMPLY WITH THE APPLICABLE SECTIONS OF ALL STATE AND LOCAL CODES (MECHANICAL CODE, BUILDING CODE, ENERGY CODE, ETC.) AND THE LATEST EDITION OF SMACNA. V V - • ' V V — • V V 77 FILE Permit too. Plan review approval is to errs and moons. Approval of construction documents does not authorize the violation of any = ;...._ = ' code or y. Retest o :�r . a �� :y = ri ~� �i.. b By .ifi Date: rf /i RG -1 • • • MANUAL VOLUME DAMPER (TYP. ) MECHANICAL GENERAL NOTES City of Tukwila BUILDING DIVISION R alas No changes shalt be made to the Q scope Of work a without NOTE: Revisions will require a new plan subm and may include additional On review lees. RG -1 ENTRANCE Q • THIS SD -1 TO BE 3 -WAY THROW. SD -1 400 1 1 • 1 1 0 11 I I 11 1 0 1 I 11 .r • RECEIVED CITY OF TUKWILA DEC 1 8 2007 • tnl �,�iy ER 11. FIRE PROTECTION PLANS MUST SE ENGINEERED AND WET SIGNED AND SEALED BY A LANDLORD APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL JURISDICTION. 12. THE GENERAL CONTRACTOR SHALL PROVIDE LANDLORD AND DELIA'S WITH AS -BUILT DRAWINGS, ALL EQUIPMENT SHOP DRAWINGS, INFORMATION ON THERMOSTATS, CONTROL WIRING DIAGRAMS AND OTHER PERTINENT INFORMATION AT COMPLETION OF PROJECT. 13. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL STRUCTURAL STEEL REQUIRED TO SUPPORT EQUIPMENT AND SHALL COORDINATE LOCATIONS AND REQUIREMENTS WITH THE LANDLORD'S REPRESENTATIVE. COST OF THIS WORK AND ANY STRUCTURAL ENGINEERING FEES REQUIRED 51 -1ALL BE INCLUDED IN THIS BID. 14. GENERAL CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING AND /OR DUCTWORK NOT BEING USED OR SHOWN TO REMAIN 15 FULLY REMOVED AND NOT ABANDONED. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 15. ALL RECTANGULAR DUCTWORK SHALL BE LINED AND ALL ROUND DUCT SHALL BE WRAPPED WITI -I A MIN. R -VALUE OF 3.7, 1.0 PCF INSULATION. REFER TO SPECIFICATIONS FOR MORE INFO. 16. COORDINATE BOX --OUT LOCATIONS FOR ALL DRYWALL MOUNTED AIR DEVICES WITH CEILING FRAMING. 17. ANY EXISTING WALL, FLOOR OR CEILING SURFACE THAT IS DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED TO MATCH NEW AND /OR EXISTING CONDITIONS AT THIS CONTRACTOR'S EXPENSE. 18. GENERAL CONTRACTOR SHALL MODIFY SPRINKLER HEADS AND PIPING FOR NEW MODIFICATIONS. RUN HYDRAULIC CALCULATIONS AS REQUIRED. REFER TO SPECIFICATIONS. DESIGN NEW LAYOUT TO MEET NFPA 13, LOCAL AUTHORITY HAVING JURISDICTION AND LANDLORD'S REQUIREMENTS. 19. GENERAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SE=RVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS AND AS REQUIRED BY THE JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING PROVIDED BY THE LANDLORD SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. FIELD VERIFY AND COORDINATE. 20. GENERAL CONTRACTOR SHALL COMPLETELY INSTALL TI-4E LISTED ACCESSORIES PER MANUFACTURER'S RECOMMENDATIONS, INCLUDING ALL TEMPERATURE CONTROL CONNECTIONS. z 0 w AC 7:3 p 0 10 ":1` 'n g , ti 10 rg 1 3 0 eN ° , =0 A, a v a a E a i� ce w°° Up rw • P_ cvOQ ow I Esw LLI coc:c v a o� M w THE ENGINEER ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLYAUTHORIED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL. THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA SAI # 07418 DRAWING NUMBER: M1.0 MECHANICAL RESPONSIBILITY SCHEDULE L = LANDLORD G = GENERAL CONTRACTOR D = dELIA *S E = EXISTING SUPPLIED INSTALLED KEYNOTES GENERAL NOTE: THIS SCHEDULE IS INTENDED AS A "QUICK" REFERENCE. ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED ON THESE DRAWINGS. IF THE CONTRACTOR ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS 1-115 RESPONSIBILITY TO INFORM DELIA'S CONSTRUCTION MANAGER 50 THAT THESE ITEMS CAN BE CLARIFIED FOR THE CONTRACTOR. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR, AND ALL SUB-CONTRACTORS, TO FIELD VERIFY ALL CONDITIONS PRIOR TO BID. ITEM PROPRIETARY VENDOR AND CONTACT INFORMATION HVAC AND PLUMBING WORK FAN - POWERED VARIABLE AIR. VOLUME UNIT WITH ELECTRIC HEAT D G 1 CONTACT DELIA'S NATIONAL ACCOUNT REPRESENTATIVE. DEMOLITION (DUCT, PIPING, FIXTURES, EQUIPMENT, ETC.) - - - NOT APPLICABLE. VIBRATION ISOLATION STRUCTURAL SUPPORTS FOR VAV UNITS AS REQUIRED G G 2 DAMPER DIFFUSERS AND GRILLES D G 1 CONTACT DELIA'S NATIONAL ACCOUNT REPRESENTATIVE. WALL AND /OR CEILING FIRE DAMPERS AND /OR COMBINATION FIRE -SMOKE DAMPERS - - - NOT APPLICABLE. ALL DUCTWORK (LOW PRESSURE, MEDIUM PRESSURE, FLEXIBLE DUCT, ETC.) G G NON- -SALES 597 ADJUSTABLE SENSOR FOR TEMPERATURE CONTROL D G 1 CONTACT DELIA'S NATIONAL ACCOUNT REPRESENTATIVE_ TIE -IN TO LANDLORD'S CONTROLS G G 2 ALL MATERIALS AND LABOR REQUIRED FOR TIE -IN. SMOKE EXHAUST AIR MOTOR OPERATED DAMPER ACTUATORS - - - NOT APPLICABLE. SMOKE DETECTORS WITHIN PLENUM SPACE - - - r:0i LvvCL9 r'vK NOT APPLICABLE. I CODE COMI�L�AftirF CEILING MOUNTED SMOKE DETECTORS - - - NOT APPLICABLE. 1 APPROVED ZONE DAMPERS - - - NOT APPLICABLE. 1 JAN -2 2008 DUCT MOUNTED HEATERS - - - INTEGRAL TO VAV BOXES. 1 UNIT HEATERS - - - y tali IUKWi(a : NOT APPLICABLE. � ay DiVicinKi RETURN AIR AND /OR RELIEF AIR FANS - - - NOT APPLICABLE. TOILET EXHAUST FANS D G 1 CONTACT DELIA'S NATIONAL ACCOUNT REPRESENTATIVE. AIR BALANCE REPORT G G SUBMIT TO ARCHITECT, ENGINEER AND DELIA'S PLUMBING FIXTURES /APPURTENANCES REQUIRED FOR ROUGH -IN G G * NCO, FCO, FD -1, W4-1A, TP, VALVES, PIPING, TRAPS, WALL BRACKETS (OR WALL CARRIERS), ETC. PLUMBING FIXTURES D G 1 WC -I, LAV -1, EWC -1, MS -1, 1,• - CONTACT DELIA'S NATIONAL ACCOUNT REPRESENTATIVE. WASTE AND WATER PIPING AND WATER METER AS REQUIRED G G 2 © SPRINKLER PIPING, HEADS, PERMITS, DRAWINGS, FEES, ETC. G G PERMITS, FEES, INSPECTIONS, ETC. G G 10"0 O ©O RESPONSIBILITY SCI - IEDULE CODED NOTES INSTALLED BY GENERAL CONTRACTOR. CONTACT DELIA'S NATIONAL ACCOUNTS WITH LANDLORD PRIOR TO BID. 0 PROVIDED BY DELIA'S THROUGH THEIR VENDOR AND REPRESENTATIVE (TRANS AT 1 -800- 598 -4545) TO COORDINATE. 0 GENERAL CONTRACTOR TO COORDINATE REQUIREMENTS AIR DEVICE SCHEDULE TAG TYPE BORDER THROW % MATERIAL ACCESSORY SYMBOL KEY - FIRST LETTER: SECOND KEY OCCUPANT CLASS S-- SUPPLY R- RETURN E- EXHAUST D- DIFFUSER R- REGISTER G- GRILLE SD--? Lt I I ER: TAG— `� DI FFUSER 131e1 2e1 GRI LLE LI NEAR DI FFUSER SURFACE MOUNTED NI - W1 AVM AVM - Z ANYM- VM -fr - 13315 wnNiwn1IV � f 1St7''1d DAMPER EQUAL. GRID Zl3d 3ZlI XXX �� CFM MODEL NO.Oi SIZE REMARKS FACE NECK SD -1 P'N -la V 900 250 NON -SALES NON- -SALES 597 2 2 0.15 CFM /FT OO 20 VAV -2 260 • CORRIDOR SPD 24 "x24" 12 4) ©QO. 0.05 CFM /FT SD -2 TOTAL: 956 Q Q HC LAV TOILET 94 1 SPD 12 "x12" 6" O 0Q0. 75 SD -3 HC LAV TOILET 75 1 t 75 75 EF -1 75 O TOTAL: 3640 SPD 24 "x24' 5 11 9 5 ©. * SD -4 Q QQ © SPD 24 "x24" 10"0 O ©O RG_1 Q® ®Q Q SPD 24 "x24" - O •41:pO RG -2 Q SPD 12 "x12" - . ©QO RG -3 Q . 0 SPD 24 "x24" - O ©* VARIABLE AIR VOLUME (VAV BOX) UNIT SCHEDULE OUTSIDE AIR REQUIREMENT SCHEDULE MFR ., M MODEL ROOM NAME ASHRAE OUTSIDE AIR REQUIREMENTS MOTOR SYSTEM MARK ACT OA CFM/ UNIT OCCUPANT CLASS 5Q. FT. OCCUPANT LOAD CFM PER OCCUPANT READ. WATTS HP SALES SALES 2736 89 VAV -1 0.3 CFM /FT 821 650 VAV -1 850 1,500 277 1 FR FITTING ROOM 176 5 250 0.2 CFM /FT 36 VAV -2 P'N -la V 900 250 NON -SALES NON- -SALES 597 2 2 0.15 CFM /FT 90 20 VAV -2 260 CORRIDOR CORRIDOR 162 1 0.05 CFM /FT 9 TOTAL: 956 1,100 HC LAV TOILET 94 1 Tr 75 75 EF -1 75 HC LAV TOILET 75 1 t 75 75 EF -1 75 TOTAL: 3640 150 150 * USE ASHRAE 3 HR RULE FOR VENTILATION ** CFM / SQ. FT. t EXHAUST PRIMARY AIR PROVIDED BY LANDLORD ROOF TOP UNIT. OUTSIDE AIR, INCLUDING FULL 100% ECONOMIZER MODE SHALL BE PROVIDED WITH PRIMARY AIR FROM LANDLORD RTU. VARIABLE AIR VOLUME (VAV BOX) UNIT SCHEDULE UNIT NO. MFR ., M MODEL AIR VALVE EXT. MOTOR HEATING DATA MCA MOCP WEIGHT (LBS.) REMARKS MAX. S.P. M FM WATTS HP AN F VOLTS PHASE STAGES 14 EAT VAV -1 1 T TRANE 3 650 0.50" 1/2 1,500 277 1 2 16.0 33.q 35 250 Oa..4:0 VAV -2 P'N -la V 900 250 0.50" 1/3 750 277 1 2 10.0 18.1 20 150 © . Q EXHAUST FAN SCHEDULE UNIT NO. MFR., MODEL NO. TYPE C.F.M. S.P. IN. W.G. WHEEL R.P.M. MOTOR SERVING LOCATION REMARKS H -P- ATTS RPM VOLTS PHASE EF ^1 GROAN L150 CLG. EX1-4. 75 0.5 1500 ^- 70 1750 120 1 RySTROOM ... r / A A 25 -I/4" 19 -I /4" O R s. - f 23 ", 19 ", 17" OR 11" f INSIDE DIMENSION 7 V MAIN DUCT 1" ACOUSTICAL LINING OWN EXTERNAL ION MINIMUM INSTAL R VALUE OF 3.7 ALL DUCT LINER TRANSVERSE EDGES TO BE COATED WITH ADHESIVE IN ACCORDANCE WITH SMACNA STANDARDS (TYP.) . TAPE D INSULAT FASTEN WITH MIN. (3) SHEET METAL SCREWS, SEAL WITH DUCT TAPE AND MASTIC. ROUND RIGID DUCT. FLANGED AND GASKETED JOINT OR DUCT CONNECTION AND RE- INFORCEMENT IN ACCORDANCE WITH SMACNA 2" W.G. CLASS, SEAL TRANS -VERSE -JOINTS AND LONGITUDINAL SEAMS IN ACCORDANCE W B WITH SMAGNA CLASS "" (TYP_). ROUND DUCT TAKE -OFF DETAIL SCALE: NONE LED CONICAL OR BELLMOUTI -I SPIN -IN FITTING, SEAL AIR TIGHT WITH MASTIC. VOLUME DAMPER LOCATION WHERE ABOVE LAY -IN CEILING. PROVIDE WITH LOCKING QUADRANT. O BASED ON PRICE AS FURNISHED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE AND INSTALLED SY GENERAL CONTRACTOR- O UNLESS SHOWN OTHERWISE ON DRAWINGS. O VERIFY ARRANGEMENT WITH CEILING TYPE (LAY --IN, SURFACE MOUNT, ETC.) PROVIDE WITH PRICE MODEL #SPF FRAME FOR DRYWALL CEILING MOUNTING. FLOW 25 -I/4 ", 21 -1 /4 ", 19 -1/4" OR 13 -1/4" OUTSIDE DIMENSION 0 1 PROVIDE UNIT WITH DIGITAL ELECTRONIC (DDC) CONTROLS, TWO (2) q.OKW .1 STAGES OF HEAT (18.0K TOTAL) AT 480V- 3P1-1, FIELD INSTALLED SOUND ATTENUATOR AND TRANE #k05SQ FAN. O PROVIDE UNIT WITH DIGITAL ELECTRONIC (DDC) CONTROLS, TWO (2) 5.OKW STAGES OF HEAT (10.OKW TOTAL) AT 480V -3PH, FIELD INSTALLED SOUND ATTENUATOR AND TRANS #035Q FAN. 0 UNITS PROVIDED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE AND INSTALLED BY GENERAL CONTRACTOR. O CONTROLS PROVIDED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE AND INSTALLED BY GENERAL CONTRACTOR. ALL MATERIALS AND LABOR REQUIRED TO TIE -IN CONTROLS WITH LANDLORD'S SYSTEM SHALL BE THE RESPONSIBILITY OF GENERAL CONTRACTOR. 24", 20 ", 18" OR 12" 1 NOTE: ROUGH -IN OPENING S ZES: CONTACT MANUFACTURER FOR INFORMATION. O CONTROL WITH LIGHT SWITCH. O PROVIDE WITH DISCONNECT SWITCH, INTEGRAL BACKDRAFT DAMPER AND SPEED CONTROL MOUNTED ON FAN. € BASED ON GROAN AS FURNISHED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE AND INSTALLED BY GENERAL CONTRACTOR. PER WASHINGTON STATE NON - RESIDENTIAL ENERGY CODE: - ALL THERMOSTATS /CONTROLS SHALL HAVE 5 DEGREE DEADBAND. - 100% OUTSIDE AIR ECONOMIZER CYCLE REQUIRED. - ALL THERMOSTATS /CONTROLS SHALL BE PROGRAMMABLE FOR 7 DIFFERENT DAY SETTINGS AND NIGHT SETBACK. 21 -1/4 ", 13 -1 /4" 1 -1/2" 1 V- — 1 1/8" DRYWALL MOUNTING FRAME DETAIL SCALE: NONE O PROVIDE WITH DAMPER/EXTRACTOR OPERABLE FROM FACE. O PROVIDE WITH NECK MOUNTED OPPOSED BLADE DAMPER OPERABLE FROM FACE. AIR DEVICE TO BE STANDARD WHITE FINISH. �S PROVIDE WITH RADIUSED ENDCAPS BASED ON OUTSIDE DIAMETER OF SPIRAL DUCT (DRAWINGS INDICATE INSIDE CLEAR DIMENSION - ADD FOR LINER/DOUBLE WALL DUCT). / -- "C" CHANNEL REINFORCING BY G.G. AROUND OPENING MOUNTING SCREW FIELD INSTALLED DRYWALL CEILING ��STEEL MOUNTING FRAME FROM S.A. MAIN SECURELY TAPE VINYL FLEX DUCT TO SHEET METAL WITH MINIMUM OF (2) CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FLEX DUCT INSULATION AND VINYL TO SHEET METAL. TAPE INSULATION TO DUCT TO FORM A GOOD SEAL. MANUAL VOLUME DAMPER MOUNTED IN NECK OF AIR DISTRUBITION DEVICE AND OPERABLE FROM FACE. SUPPLIED WITH AIR DEVICE. SUPPLY AIR DIFFUSER (LAY -IN FRAME, STEEL MOUNTING FRAME REQUIRED FOR DRYWALL CEILING INSTALLATION SEE DETAIL B ON THIS SHEET) INSULATED FLEXIBLE CONNECTION (MIN. 2 FT., MAX. 5 FT.) TRANSITION FROM DUCT SIZE TO DIFFUSER NECK SIZE AS NECESSARY DIFFUSER MOUNTING DETAIL SCALE: NONE City Name , . Seattle IAP Location Washl ngton Latitude .......::..... . ...... ........:.:; ....:............... , ..,.... Eleva Longitude tion 122.3 449 0 r .. 85:0 Summer Coincident Wet -Bulb ... :...:.. :...... . : : .... .. . .........:......... ... .• :.•_ -- 65.0 Summer Daily Range 8.3 Winter Summe Desi gn Desig Dry n D -B y u lb Atmospheric Clearness Number Average Ground Refieutance Loc al lime Zone (GMT -1- N hours) Consider Daylight Savings Time ...... Simulation Weather Data Current Data is ........ .....:... • .... Design Cooling Months ZONE LOADS Window &' Skylight Solar Loads Wail Transmission Roof Transmission Window Transmission Skylight .Transmission Door Loads" Floor Transmission Partitions Celling Overhead Lighting Task Lig hti ng Eleotric Equipment People Infiltration Miscellaneous Safety Factor > .Total Zone Loans Zone Conditioning Plenum Wall Load Plenum Roof Load Plenum Lighting Load Return Fan Load Ventilation Load Supply Fan Load Space Fan Coil Fans Duct Heat Gain/ Loss » Total System Loads Central Cooling Coil Terminal Reheat Coils » Total Conditioning Key: DESIGN WEATHER PARAMETERS 8.0 ••••• F••• •••• ••• •••• • •• ••••• ••• ...... • ... :..........,... No ......... .. ,.::.. ... noneN/A 200 .:...... ......... .:............. 1 ASHRAE Handbook� January to December AIR SYSTEM DESIGN LOAD SUMMARY COOLING DATA AT Jun 1700 COOLING OADB /WB 82.2 °F %64:4 °F Details a ft 2 011R 3 ftx 0 ft2 0 ft 2 O ft 0 ft 2 0 ft 0 ft 2 3368 W 5760 W 2865 W 10 10% / 10% 70% 30% 3996 CFM 1080 CFM 4146 CFM 10% DESIGN COOLING Sensible (BTU/hr) 0 0 5813 0 0 0 0 0 693 16946 9175 17583 0 0 5645 62097 69399 0 13564 3447 0 5671 4629 0 6210 102921 102921 0 ( +. . 102921 Positive values are cig loads Negative values are htg: loads L atent (BTU/hr) 19930 0 0 1993 21923 21923 41 17729 17727 17727 1.05 10 Deg. Deg. ft °F QF A °F BTU/(hr-ft-fl hours Details a' ft 2 3840 ft 0ft2 0 ft o ft 1 CFM 1134 CFM DESIGN HEATING HEATING DATA AT DES HTG HEATING OADB /WB 23:0 °Ff19.2°F Sensible (BTU/hr) 0 ft 0 Oft? 44343 0 0 ft? 0 0 Oft 0 0 0 0 0 0 20°fo 8869 53212 32654 0 0 0 0 984 CFM 0 299 -1795 -802 10% . 5821 65358 0 63857 63857 Positive values arehtg loads Negative values are clg loads RECEIVED CITY OF TUKWIL DEC 1 8 2007 prtivit i Et 4► Latent (BTU /hr) 0 0 0 0 a <UCIF-2 • Timm NUd Ruji. U =J 0_4:(00 L.L14("ccl,',"‹ (0 W 'Op g woc2) Wv- THE ENGINEER ASSUMES NO •.NSIBILITYOR LIABILITY FOR THE USE OF TH!SE P FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED SY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRITERIA, SAI# 07418 DRAWING NUMBER: M2.0 T-- CHECKED BY: JTP DRAWN BY: WRG DATE ISSUED: • INDICATES NO REVISION TO THIS SHEET PLUMBING, FIRE PROTECTION AND HVAC SPECIFICATIONS 15010 GENERAL PROVISIONS A. PROVIDE ALL MATERIALS AND EQUIPMI =NT AND PERFORM ALL LABOR EQUIRED TO I MATERIALS R A I- IEATING, VENTILATING, AIR CONDITIONING, SYSTEM, P AND S T A PROTECTION C ENTIL AS INDICATED ON THE DRAWINGS, AS REQUIRED BY BODE AND AS SPECIFIED HEREIN. B. WITHOUT RESTRICTING THE GENERALITY OF THE FIRST STATEMENT, THE WORK TO BE PERFORMED UNDER THIS DIVISION SHALL INCLUDE, BUT 15 NOT LIMITED TO, THE FOLLOWING: 1. PLUMBING WORK AS DESCRIBED IN SECTIONS 15010 THROUGH 15375. 2. FIRE PROTECTION WORK AS DESCRIBED IN SECTIONS 15010 AND 15410 THROUGH 15430. 3. HVAC WORK AS DESCRIBED IN SECTIONS 15010 AND 15600 THROUGH 15980. C. THE GENERAL CONTRACTOR, UNLESS OTHERWISE NOTED 15 TO PROVIDE POWER WIRING FOR EACH ITEM OF ELECTRICAL EQUIPMENT AND MAKE FINAL CONNECTIONS TO MOTORS. D. ALL FINISH PAINTING IS TO BE PERFORMED BY THE GENERAL CONTRACTOR, EXCEPT AS NOTED ELSEWHERE. GENERAL CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION ANY PAINTING DEFACED DURING CONSTRUCTION AND AFTER ORIGINAL PAINTING. E. ALL WORK SHALL CONFORM TO CODES, RULES, AND REGULATIONS: 1. NATIONAL ELECTRIC CODE. 2. STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, NFPA 90A. 3. CODE FOR SAFETY TO LIFE FROM FIRE IN BUILDINGS AND STRUCTURES, NFPA lol, 4. FEDERAL OCCUPATIONAL SAFETY AND HEALTH STANDARDS. 5. STATE MECHANICAL CODE. 6. STATE BUILDING GODS 7. STATE INDUSTRIAL COMMISSION REQUIREMENTS, 8. LOCAL BUILDING CODE REQUIREMENTS. 9. BUILDING INSURING AGENCY REQUIR>MENTS. 10. STATE PLUMBING CODE. 11 NFPA F. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION SHALL BE OBTAINED AT THE PROPER TIME BY AND AT THE EXPENSE OF THIS CONTRACTOR. G. GENERAL CONTRACTOR SHALL OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES AND PUBLIC AUTHORITY HAVING JURISDICTI AND SHALL OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE ARCHITECT AND SHALL PAY ALL FEES, CHARGES, ASSESSMENTS AND OTHER EXPENSES IN CONNECTION THEREWITH. IW. PIPING AND EQUIPMENT LAYOUT 15 SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY STRUCTURAL AND OTHER CONDITIONS. DESIGN OF SYSTEM MAY NOT BE CHANGED. ONLY EXACT LOCATION OF PIPING AND DUCTS MAY BE REVISED TO SUIT CONSTRUCTION CONDITIONS AND AID IN COORDINATION WITH WORK OF OTHER CONTRACTORS. I. TI-4E MATERIALS AND EQUIPMENT INSTALLED IN THE WORK S1.4ALL MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT 514ALL BE ORDERED UNTIL REVIEWED BY THE ENGINEER, LANDLORD AND /OR ARCHITECT. J. GENERAL CONTRACTOR SHALL SUBMIT 5140P DRAWINGS PER THE DOCUMENTS PROVIDED SY THE TENANT /CONTRACTOR. K. CATALOG DATA FOR EQUIPMENT REVIEWED BY THE ARCHITECT SHALL NOT SUPERSEDE THE ENGINEER'S CONTRACT DOCUMENTS. THE REVIEW OF THE ENGINEER 51 -4A LL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS, PROVIDING PROPER CLEARANCE, FABRICATION PROCESS AND COORDINATION WITH OTHER TRADES. L. WHEN SUBMITTED FOR THE ARCHITECT'S REVIEW, SHOP DRAWINGS SHALL BEAR THE CONTRACTORS CERTIFICATION THAT HE HAS REVIEWED, CHECKED AND APPROVED TI-4E SHOP DRAWINGS, THAT THEY ARE IN HARMONY WITH THE REQUIREMENTS OF THE PROJECT AND WITH THE PROVISIONS OF THE CONTRACT DOCUMENTS AND THAT HE HAS VERIFIED ALL FIELD MEASUREMENTS AND CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR DATA. CONTRACTOR SHALL ALSO CERTIFY THAT THE WORK REPRESENTED BY THE SHOP DRAWINGS 15 RECOMMENDED BY THE CONTRACTOR AND THE CONTRACTOR'S GUARANTEE WILL FULLY APPLY. M. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL CONDITIONS THEREIN. ALL PROPOSALS SI -IALL TAKE INTO CONSIDERATION ALL SUCH CONDITIONS AS MAY AFFECT THE WORK UNDER TI-115 CONTRACT. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES THAT THIS EXAMINATION OF SITE HAS BEEN DONE. N. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES AND NOTE CONDITIONS WHICH WOULD AFFECT THE WORK. ALL DISCREPANCIES SHALL THEN BE REPORTED PRIOR TO THE SID AWARD. 0. PROVIDE INSTRUCTION TO LANDLORD'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS A GUIDE. P. COMPILE WRITTEN MANUAL OF OPE RATING INSTRUCTIONS INCLUDING COPIES OING OF )= QUIPRU INSTRUCTIONS OF SHOP DRAWINGS AND A OF AG COP! IN B -I /2" X 11" HARD BACKED INDEXED BINDER. MATERIAL SHALL BE AS FOLLOWS: 1) TITLE PAGE: TITLE OF JOB, LANDLORD/TENANT, ADDRESS, DATE, SUBMISSION, CONTRACTOR AND ENGINEER. 2) INDEX 3) LIST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASE ORDER NUMBERS AND SUPPLIERS NAMES AND ADDRESSES. 4) ONE COPY OF EACH SHOP DRAWING GROUPED HY TYPES OF EQUIPMENT (I.E., ROOFTOP UNITS, FANS, ETC.) 5) SECTION FOR EACH SYSTEM INCLUDING: A) BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR. COMPONENTS. B) HVAC SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS AND 5Ci- 4l= MATICS. Q. SUBMIT A COMPLETED COPY TITLED "HVAC OPERATING INSTRUCTION MANUAL" ON THE BINDING EDGE OF BINDER TO ARCHITECT FOR APPROVAL. AFTER ARCHITECT'S REVIEW AND ANY CORRECTIONS REQUIRED ARE COMPLETED, SUBMIT A COPY OF THE MANUAL TO THE LANDLORD. R. WITHIN 90 DAYS AFTER. THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING LANDLORD. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON E PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT DISTRIBUTION SYSTEM INCLUDING SIZES, AND THE AIR DESIGN FLOW RATES. 5. ANY REFERENCE TO TENANT'S OR DELIA'S CONSTRUCTION MANAGER DR FURNISHED BY ANY OF THE ABOVE REFERS TO DELIA'S, INC, T. REFER TO RESPONSIBILITY SCHEDULE ON THE MECHANICAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. U. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1) WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 2) GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO DELIA'S CONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL SE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) ) WORKING DAYS FOR DELIA'S CONSTRUCTION MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND THE SUB- CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. V. DEMOLITION 1) GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF EXISTING WORK. FIELD VERIFY AND COORDINATE ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT AND PROTECT EQUIPMENT TO REMAIN DURING CONSTRUCTION. W. FINAL HVAC INSPECTIONS 1) ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, DELIA'S SHALL HAVE AN INDEPENDENT CONTRACTOR INSPECT THE FINISHED INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. X. WARRANTY AND GUARANTEE 1) DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE SHALL PROVIDE A COMPLETE 12 MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT OR MATERIALS PROVIDED THROUGH DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE. THIS WARRANTY SHALL INCLUDE ALL COSTS TO REPAIR OR REPLACE ANY DEFECTIVE PART WITH THE EXCEPTION OF DAMAGE RESULTING FROM HANDLING OR INSTALLATION THAT 15 NOT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 2) CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND LABOR PROVIDED UNDER TH1S CONTRACT AND SHALL MAKE GOOD REPAIR OR REPLACE AT NO ADDITIONAL COST ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT DISCOVERED WITHIN 12 MONTHS FROM THE DATE OF CERTIFICATE OF OCCUPANCY. TH15 GUARANTEE SHALL EXTEND TO LABOR AND MISCELLANEOUS MATERIALS REQUIRED FOR THE INSTALLATION OF EQUIPMENT FURNISHED THROUGH DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE, BUT SHALL NOT OVERLAP WITH WARRANTY PROVIDED BY MANUFACTURER. TWE CONTRACTOR 15 RESPONSIBLE TO VERIFY, COORDINATE AND FOLLOW ALL PROPER HANDLING AND INSTALLATION TECHNIQUES WITH MANUFACTURERS) IN ORDER TO MAINTAIN MANU FACT URER'5 WARRANTY. 15100 PLUMBING BASIC MATERIALS AND METHODS A. PROVIDE AND ERECT THE FOLLOWING PIPING AS SHOWN ON THE DRAWINGS AND /OR AS REQUIRED. 1. SANITARY BUILDING DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE. 2 SCHEDULE 40 PVC PIPING CAN SE USED FOR SANITARY WASTE AND VENT PIPING WHERE LOCAL CODE ALLOWS AND WITH APPROVAL FROM LANDLORD. 3. DOMESTIC HOT AND COLD WATER USE TYPE "L" HARD COPPER PIPE. B. GENERAL CONTRACTOR 15 TO BECOME INFORMED OF THE EXACT DIMENSIONS OF FINISHED WORK WHERE PIPES ARE TO BE PLACED AND WILL ARRANGE THE WORK ACCORDINGLY, ASSUMING ALL RESPONSIBILITY FOR PROPER LOCATION. IN THE ERECTION OF THE MAINS, SPECIAL CARE SHALL BE USED PROVIDING SUPPORT AND PROPER ALLOWANCES SHALL BE MADE FOR EXPANSION. C. ALL PIPE LINES MUST BE PROVIDED WITH A SUFFICIENT NUMBER OF FITTINGS OR UNIONS TO MAKE PC55!5LE DISASSEMBLY WITHOUT BREAKAGE OF FITTINGS. D. ALL EXPOSED PIPING SHALL BE NEAT AND CAREFULLY ALIGNED WITH THE STRUCTURAL ELEMENTS OF THE BUILDING. NO OFFSETS OR OBLIQUE BENDS WILL BE PERMITTED. DRAWINGS ARE DIAGRAMMATIC AND SHOULD NOT BE USED FOR LAYOUT WORK. E. ALL LOW POINTS IN WATER PIPING TO HAVE DRAIN VALVES WITH STANDARD H ATTACHMENTS. HOT AND COLD WATER PIPING IS TO PITCH TOWARD THE NEAREST DRAIN VALVE. F. ALL PIPES TO BE INSTALLED SHALL BE LOCATED AT SUFFICIENT DISTANCE FROM WALLS, OTHER PIPES, CONDUIT, DUCTWORK AND OTHER OBSTACLES TO AVOID INTERFERENCE AND TO PERMIT THE APPLICATION OF FULL THICKNESS OF INSULATION SPECIFIED. G. MECHANICAL JOINT TYPE PIPING SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. 15130 EXCAVATION AND BACKFILL A. GENERAL. CONTRACTOR SHALL EXCAVATE AND BACKFILL ALL TRENCHES AND OTHER EXCAVATIONS REQUIRED FOR LAYING DRAINS, SEWERS, APPURTENANCES AND OTHER EXCAVATIONS REQUIRED FOR THIS WORK. S. EARTH FILL: SOIL AS APPROVED SY THE OWNER'S REPRESENTATIVE, FREE OF ORGANIC SOIL, SOD, ROOTS, WOOD, METAL, RUBBISH, DEBRIS, LUMPS OR EXCESSIVE AMOUNTS OF CLAY AND ROCKS GREATER THAN 2" IN DIAMETER; CAPABLE OF BEING COMPACTED INTO DENSE AND STABLE CONDITION AS SPECIFIED, C. ALL UNDERGROUND PIPING SHALL BE INSTALLED ON A MINIMUM OF A 3" SED OF COMPACTED SAND. ALL UNDERGROUND PIPING SHALL BE BAGKFILLED BY HAND TO A LEVEL OF 6" ABOVE THE PIPE WITI.4 GLEAN SAND. ALL BACKFILL SHALL SE MADE IN LIFTS NOT TO EXCEED 12 ", EACH LIFT SHALL BE MECHANICALLY COMPACTED TO A MINIMUM OF 92% MODIFIED PROCTOR. D. PROTECT ALL UTILITIES SHOWN ON DRAWINGS OR ENCOUNTERED IN THE CONSTRUCTION WORK, ANY DAMAGE TO UTILITIE'S SHALL BE REPAIRED BY CONTRACTOR TO DELIA'S SATISFACTION, WITI -40UT COST TO DELIA'S, E. GENERAL CONTRACTOR SHALL REMOVE ANY UNUSABLE OR SURPLUS EXCAVATED MATERIAL FROM SITE. 15200 PLUMBING SYSTEMS A. BUILDING DRAIN, SOIL, WASTE AND VENT LINES SHALL BE SERVICE WEIGHT CAST IRON HUBLESS PIPE WITH STAINLESS STEEL AT COUPLINGS. SCHEDULE 40 PVC MAY BE USED FOR SANITARY NASTE AND VENT PIPING WHERE ALLOWED BY LOCAL CODE AND WITH APPROVAL OF LANDLORD. 5. VENT STACKS SHALL EXTEND THROUGH THE BUILDING, TERM I NAT ING 12" ABOVE THE ROOF. STANDARD FLASHING SHALL BE EXTENDED 12" IN ALL DIRECTIONS FROM THE VENT TERMINAL AND TURNED DOWN INTO VENT. FLASHING UNITS AS MADE SY STONEMAN CAULK TYPE NO. 51110 -4 MAY BE USED IN LIEU OF FIELD FABRICATED FLASHINGS. G. HORIZONTAL RUNS SHALL BE GIVEN AS STEEP A PITCH TOWARD THE OUTLET AS CONDITIONS WILL PERMIT BUT NOT LESS THAN i /$" PER FOOT. D. FULL "Y" BRANCH FITTINGS AND EXTENSION WITH BRASS NIPPLES AND FULL ULL " Y " SCREW PLUGS FOR C XTNS SHALL >3E PLACED IN ACCESSIBLE POSITIONS AT ENDS OF HORIZONTAL LINES OF PIPE AND AT FOOT OF ALL VERTICAL LINES OF PIPE OR ELSEWHERE, AS MAY BE REQUIRED BY THE GODS E. WHERE CLEANOUTS OCCUR IN FINISHED AREAS, THEY SHALL BE RECESSED AND COVERS TO BE FLUSH WITH THE FLOOR OR WALL. HOT AND COLD WATER PIPING ABOVE GROUND SHALL BE TYPE "L" HARD COPPER TUBE WITH SOLDER FITTINGS. EXPOSED PIPING AT FIXTURES SHALL BE CHROME PLATED BRASS, G. ALL COPPER TU131NG SHALL HAVE SWEAT JOINTS AND BE CLEAN OF SCALE AND FOREIGN MATTER BEFORE INSTALLATION. ALL ENDS OF TUB NG TO BE SWEATED SHALL BE REAMED, CLEANED AND BURNISHED TO REMOVE DIRT AND OXIDE. HARD 95--5 SOLDER SHALL BE USED AND APPLIED TO THE JOINTS ACCORDING TO STANDARD PRACTICE AND /OR MANUFACTURER'S RECOMMENDATIONS. SUITABLE ADAPTERS SHALL SE USED AT CONNECTION TO EQUIPMENT. H H , EACH AND COLD WATER BRANCH SHALL BE PROVIDED WITH A GATT= VALVE SHUT -OFF AND EACH FIXTURE SHALL B1= PROVIDED WITH A STOP VALVE. 15250 EQUIPMENT IDENTIFICATION A. STENCILS, LABELS, TAGS, AND COLOR CODES SHALL CONFORM TO ANSI A13. B. PRODUCTS SHALL BE SETON. EQUAL PRODUCTS BY BRADY MAY BE FURNISHED AT CONTRACTOR'S OPTION. C. STENCILS SHALL SE REUSABLE AND HAVE 1" HIGH CHARACTERS. CHARACTERS SHALL BE PAINTED WHITE OVER A SLACK BACKGROUND. INCLUDE ON PIPING A WHITE (OR BLACK) STENCILED ARROW IN FLOW DIRECTION NEXT TO STENCIL. STENCIL ONLY AFTER FINAL PAINTING IS COMPLETE. CHARACTERS SHALL BE LEGIBLE FROM FLOOR. APPLY CLEAR ACRYLIC, LACQUER, OR VARNISH OVER THE FINISHED STENCIL. D. PREPRINTED FLEXIBLE VINYL. LABEL WITH PERMANENT PRESSURE SENSITIVE ADHESIVE BACK MAY BE USED ON PIPE INSTEAD OF STENCIL. LABEL SHALL BE OF SUFFICIENT LENGTH TO ENCIRCLE THE PIPE (AND INSULATION WHEN APPLICABLE) AND OVERLAP ON ITSELF. EACH LABEL SHALL HAVE AT LEAST ONE FLOW DIRECTION ARROW AND 51-IALL BE PERMANENTLY LABELED WITH PIPE CONTENT. E. PIPING, VALVES, DRAINS, CONTROL PANELS AND SIMILAR EQUIPMENT SHALL 13E IDENTIFIED AS TO FUNCTION AND SYSTEM NUMBER AS DIRECTED BY THE OWNER'S REPRESENTATIVE AND AS LISTED BELOW ITEM IDENTIFICATION TYPE 15350 INSULATION A. PIPE INSULATION AND APPURTENANCES AND COVERINGS ON PIPES USED IN CHASES, SHAFTS OR OTHER CONCEALED SPACES IN TYPES 1 AND 2 CONSTRUCTION SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING TWENTY -FIVE (25) AND IN TYPE 3 AND 4 CONSTRUCTION NOT EXCEEDING SEVENTY --FIVE (75) AND A SMOKE DEVELOPED RATING NOT EXCEEDING FIFTY (50)• $• INSULATION SHALL BE SCHULLER 1"IIGRD -LOK 650 FIBERGLASS WITH FACTORY APPLIED ALL SERVICE JACKET WITH SELF - SEALING TAPE. INSULATION SHALL LIMIT HEAT LOSS TO 25 BTU /HR. /SQ.FT. OF PIPE SURFACE WITH 55 DEGREES AMBIENT, AND SHALL BE 1/2" THICK ON COLD WATER PIPING AND 1" THICK ON HOT WATER PIPING. C. GLUE IN PLACE WITH SCHULLER U -GLUE . D. THE FITTINGS SHALL BE INSULATED WITH SCHULLER ZESTON INSULATION AND HAVE FACTORY PREMOLDED PVC COVERS. BUTT THE JOINTS TOGETHER AND WRAP WITH 3" WIDE STRIP TAPE, SEAL IN PLACE WITH SCHULLER U -GLUE. E. INSULATION SHALL NOT BE APPLIED UNTIL THE GENERAL CONSTRUCTION HAS PROGRESSED SUFFICIENTLY TO INSURE AGAINST PHYSICAL- OR MOISTURE DAMAGE TO THE INSULATION. ALL INSULATION DAMAGED THROUGH FAILURE TO OBSERVE THIS DIRECTIVE SHALL BE REPLACED BY CONTRACTOR AT CONTRACTOR'S EXPENSE. F. INSTALL ALL INSULATION ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. G. INSULATION SHALL NOT BE APPLIED OVER FLANGES, JOINTS AND SEAMS IN PIPING. H. INSULATION SHALL BE SCHULLER. EQUAL PRODUCT BY ARMSTRONG, CERTAINTEED, OWENS- CORNING OR KNAUF MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 15375 PLUMBING SYSTEM TESTING. A. SYSTEM TESTING SHALL PROVIDE FOR THE FOLLOWING= 1, TEST NEW INTERIOR DOMESTIC WATER SYSTEM, 2. TEST ALL SOIL, WASTE, AND VENT PIPING. 3. FURNISH ALL PUMPS FOR AIR AND WATER PRESSURE TESTS ALONG WITH GAUGES AND ANY OTHER REQUIRED TEST EQUIPMENT. 4. UNDERGROUND LINES TO BE TESTED BEFORE BEING CONCEALED. CONTRACTOR SHALL REPAIR ANY LEAKS AND ALL DAMAGE RESULTING THEREFROM. 5. CHANGES IN AMBIENT TEMPERATURE WILL BE TAKEN INTO ACCOUNT WHEN TESTING UNDERGROUND PIPING, HOWEVER, THE VARIOUS SYSTEMS SHALL BE THOROUGHLY INSPECTED FOR LEAKS BEFORE HYDROSTATIC PRESSURE TESTS ARE CONCLUDED. 6. INTERIOR WATER PIPING: HYDROSTATIC TEST AT 125 PSI ANNA PROCEDURES. 7. 501L, NASTE, AND VENT PIPING SHALL HE WATER AND SMOKE OR AIR TIGHT (STATE PLUMBING CODE). g MEASURE LEAKAGE BY METERING WATER REQUIRED TO MAINTAIN LINE PRESSURE. REMOVE AIR BEFORE TESTING. C. REPAIR ANY LEAKING JOINTS AND DEMONSTRATE ACCEPTABLE LEAKAGE TO P AND APPROVING AUTHORITY. SATISFACTION OWNER'S PLACING FLUSH ALL PI PININ G BEFORE PLLACING G ENT INTO O OPERATION!. E CEVVOMEP91411. �� PP ■ JAN - 2 2V3 C ,+„ = �y Of ilikvvii- . * IW NG • �! M RECEIVED CITY OF TUKVVILA DEC 1 8 2 Ptruvu i Ct PIPING STENCIL OR PIPE LABEL. VALVES TAG PIPING SPECIALTY TAG WATER HEATER AND OTHER EQUIPMENT STENCIL F. IDENTIFY PIPE LINES WITH STENCIL OR PIPE LABEL WITH COLOR CODED SANDS AT THE FOLLOWING LOCATIONS: 1) AT EQUIPMENT CONNECTION AT EACH VALVE. 2) AT BOTH SIDES OF WALLS THROUGH WHICH PIPE PASSES. 3) AT EVERY 20 FT. INTERVAL ON CONTINUOUS PIPE LINES. 4) AT EACH BRANCH CONNECTION. 5) SHOW FLOW DIRECTION ARROWS AT EACH IDENTIFICATION POINT. 15275 STERILIZATION A. STERILIZE NEW DOMESTIC WATERLINES AFTER INSTALLATION. 5. FURNISH A CERTIFICATE OF STERILIZATION AND APPROVAL FOR HUMAN CONSUMPTION TO BE SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THIS STATE, REGULARLY EMPLOYED BY THE TESTING LABORATORY. CERTIFICATE MUST BE GIVEN TO THE ARCHITECT AND OWNER BEFORE FINAL PAYMENT WILL BE MADE. C. STERILIZATION SHALL BE BY MEANS OF CHLORINE INJECTED INTO THE WATER NEAR THE SOURCE AND OUTLETS THROUGHOUT THE SYSTEM SHALL BE TESTED TO PROVE PRESENCE OF MINIMUM REQUIREMENTS. LEAVE CHLORINE IN FOR 24 HOURS AND FLUSH OUT SYSTEM UPON COMPLETION OF WORK. SEND DOCUMENTATION ON OFFICIAL LETTERHEAD OF TESTING LABORATORY TO DELIA'S AND ENGINEER AFTER STERILIZATION. D. STERILIZATION SHALL BE PERFORMED UNDER. THE IMMEDIATE SUPERVISION OF A WATER TESTING LABORATORY REGULARLY ENGAGED IN THE SERVICE AND SHALL. BE DONE ACCORDING TO THEIR INSTRUCTIONS. 15300 ELECTRIC WATER HEATER A. INSTALL ELECTRIC WATER HEATER AS FURNISHED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE AS INDICATED ON THE DRAWINGS, a TANK TYPE ELECTRIC WATER HEATER WITH GLASS -LINED TANK RATED AT 150 P51 WORKING PRESSURE, MAGNESIUM ANODE PROTECTION, BRONZE DRAIN VALVE, HIGH TEMPERATURE CUT --OFF SNITCH AND IMMERSION THERMOSTAT, C. TURI= AND FURNISH AND INSTALL A NATTS NO. 40L, 3/4" TEMP RELIEF VALVE D AND EXTEND W N DISGNARGE PIPE, FUE TEMPERATURE RA TEMPERATURE PPRESSURE A W ND IN 6" ABOVE THE JANITOR'S RECEPTOR OR FLOOR DRAIN. D. PROVIDE AMTROL EXPANSION TANK A5 SIZED ON THE DRAWINGS. EQUAL PRODUCTS BY BELL AND GOSSETT OR ADAMSON MAY BE PROVIDED AT THE CONTRACTOR'S OPTION. 15325 PLUMBING FIXTURES AND EQUIPMENT A. VALVES TO BE AS FOLLOWS: 1. 125 LS. S.W.P. GATE, GLOBE AND CHECK VALVES: 2. BALL (2 -1/2" AND SMALLER) -- ALL BRONZE, TEFLON STEM SEALS AND SEAT, 1/4 TURN SHUT -OFF, VINYL COVERED HANDLES. 3. CHECK (2 -1/2" AND SMALLER) - ALL BRONZE, SCREWED, HORIZONTAL SWING CHECK IA 1 BRONZE DISC. B. VALVES SHALL BE MILWAUKEE. EQUAL PRODUCTS BY CRANE, HAMMOND, POWELL, WALWORTH, NORTHERN INDIANA BRASS COMPANY OR STOCKHAM MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. C. UNIONS TO BE AS FOLLOWS: 1. UNIONS FOR COPPER PIPE TO SE 150L13., ALL BRONZE, SOLDER END TYPE BY CHASE, EQUAL PRODUCTS HY CRANE, MUELLER OR NORTHERN INDIANA BRASS COMPANY MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 2. DIELECTRIC UNIONS BETWEEN FERROUS AND COPPER SHALL BE INSULATED TO PREVENT METAL -TO -METAL CONTACT AND SHALL BE MANUFACTURED BY CAPITAL MANUFACTURING COMPANY OF COLUMBUS, OHIO. EQUAL PRODUCTS BY PATROL OR PECO SALES COMPANY D. WATER CLOSETS, URINALS AND LAVATORIES 54-4ALL BE VITREOUS CHINA BY AMERICAN STANDARD AS FURNISHED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE AND INSTALLED BY GENERAL CONTRACTOR. INSTALL. PER ADA REQUIREMENTS. E. ALL WALL HUNG LAVATORIES, FLUSH VALVES, ETC., BI -TALL BE MOUNTED AT THE MANUFACTURER'S RECOMMENDED ROUGHING IN MEASUREMENTS, UNLESS NOTED OTHERW151 =. F. FLOOR DRAINS TO BE AS FOLLOWS: 1. CAST IRON BODY SHALLOW SUMP DRAIN WITH DOUBLE DRAINAGE FLANGE AND WEEPHOLES, FLASHING CLAMP, BOTTOM OUTLET WITH NEOPRENE GASKET INSID) CONNECTOR, o" DIAMETER ADJUSTABLE GRATE. FRAME AND GRATE TO HAVE POLISHED NICKEL- BRONZE FINISH. SEE DRAWINGS FOR MODEL AND MANUFACTURER. EQUAL PRODUCT MAY BE SUPPLIED AT THE CONTRACTOR'S OPTION. G. CLEANOUTS TO BE AS FOLLOWS: 1. FLOOR TYPE TO BE ADJUSTABLE CAST IRON WITH NICKEL BRONZE TOP. TOP TO BE FLUSH WITH FLOOR. SEE DRAWINGS FOR MODEL AND MANUFACTURER. 2. WALL TYPE TO BE CAST IRON TEE WITH ROUND POLISHED STAINLESS STEEL ACCESS COVER AND THREADED PLUG. SEE DRAWINGS FOR MODEL AND MANUFACTURER. - 15410 FIRE PROTECTION GENERAL PROVISIONS A. MODIFY THE EXISTING SPRINKLER SYSTEM AND FURNISH ALL MATERIALS, LABOR, TOOLS, ADMINISTRATION, TRANSPORTATION, INCIDENTALS AND APPURTENANCES WHICH ARE REQUIRED TO COMPLETE IN EVERY DETAIL AND LEAVE IN WORKING ORDER ALL ITEMS OF WORK CALLED FOR HEREIN OR SHOWN ON THE ACCOMPANYING DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR CONNECTING TO T1-4E LANDLORD'S FIRE ALARM SYSTEM. COORDINATE WITH LANDLORD'S APPROVED FIRE ALARM AND SPRINKLER CONTRACTORS. B. INCLUDE ANY MINOR ITEMS OF WORK NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIVE FIRE PROTECTION SYSTEM. C. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT HAZARD CLASSIFICATION, AS WELL A5, THE QUANTITY, SPACING, AND PROTECTED AREA LIMITATION OF SPRINKLER HEADS. CONTRACTOR SHALL FURTHER BE RESPONSIBLE FOR CONFIRMING HIS DETERMINATION WITH THE OWNER'S INSURING AGENCY AND THE LOCAL FIRE AUTHORITY HAVING JURISDICTION OVER THE PROJECT. D. WHERE APPLICABLE, LOCATE SPRINKLER HEADS IN CENTER OF CEILING TILE, USE ARMOVER ON ALL SPRINKLER BRANCH LINES TO ACCOMPLISH EXACT LOCATION OF HEAD. E. PROVIDE AN NFPA -13 APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM IN BUILDING. SYSTEM SHALL BE APPROVED BY THE LOCAL AND STATE FIRE MARSHAL'S OFFICE. F. THE INSTALLING CONTRACTOR SHALL BE LICENSED AND CERTIFIED IN THE INSTALLATION OF AUTOMATIC SPRINKLER SYSTEMS IN T1415 STATE G. CONTRACTOR SHALL OBTAIN AND PAY FOR ANY INSPECTION FEES, CHARGES, AND ANY OTHER GOVERNMENTAL FEES APPLICABLE. CONTRACTOR SHALL FILE ALL NECESSARY DRAWINGS, SPECIFICATIONS, CONTRACTOR'S MATERIAL AND TEST CERTIFICATES. I. CONTRACTOR SHALL OBTAIN A CERTIFICATE OF INSPECTION AND APPROVAL AND SUBMIT TO THE ARCHITECT PRIOR TO THE REQUEST FOR FINAL PAYMENT. CONTRACTOR SHALL PROVIDE ALL PRODUCTS AND LABOR REQUIRED TO COMPLETE THE INSTALLATION OF ALL FIRE PROTECTION SPRINKLER SYSTEMS. FIRE PROTECTION PIPING AND EQUIPMENT LAYOUT SHALL BE COORDINATED WITH ALL EQUIPMENT, BOTH KNOWN AND UNKNOWN, AND EQUIPMENT INCLUDED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. L. ALL FIRE PROTECTION PIPING SHALL BE INSTALLED AS CONCEALED WORK, WHERE APPLICABLE. THE ARCHITECT RESERVES THE RIGHT TO CHANGE THE LOCATION OF ANY SPRINKLER HEAD DURING THE SUBMITTAL PROCESS EVEN IF THE MOVE SHOULD REQUIRE ADDITIONAL HEADS. FILL ANNULAR SPACE BETWEEN SLEEVE AND PIPE OR INSULATION ON ALL PENETRATIONS THROUGH FIRE RATED WALLS. FIRESTOPPING MATERIALS SHALL BE UL CLASSIFIED AND MEET THE REQUIREMENTS OF ASTM. THE METHOD OF INSULATION SHALL CONFORM TO UL FIRE RESISTANCE DIRECTORY. O. CEILING GRID SYSTEMS SHALL NOT BE USED TO SUPPORT FIRE PROTECTION ITEMS, PIPING, OR ANY OTHER EQUIPMENT. EACH UTILITY AND THE CEILING GRID SYSTEM SHALL BE A SEPARATE INSTALLATION AND EACH SI-IALL BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. WHERE INTERFERENCE OCCURS, IN ORDER TO SUPPORT EQUIPMENT OR CEILING GRID SYSTEM, CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL NOT BE LOCATED WHERE THEY INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, LIGHT FIXTURES, AND OTHER MECHANICAL OR ELECTRICAL ITEMS. INSTALL ALL SPRINKLER HEADS IN ROOMS IN AN ESTHETIC MANNER. SPRINKLER ARRANGEMENT SHALL BE PARALLEL AND PERPENDICULAR TO THE BUILDING WALLS. COORDINATE WITH ARCHITECT AND TENANT. CONTRACTOR SHALL VERIFY THE LOCATION OF UTILITIES AND NOTE CONDITIONS WHICH WOULD AFFECT THE WORK. ALL DISCREPANCIES SHALL THEN BE REPORTED TO THE LANDLORD'S TENANT COORDINATOR PRIOR TO THE BID AWARD. INSTALLATION WILL NOT BE CONSIDERED COMPLETE UNLESS AND UNTIL WRITTEN ACCEPTANCE I5 RECEIVED FROM THE STATE FIRE MARSHAL AND THE LANDLORD'S INSURING AGENCY. CONTRACTOR TO MAINTAIN ONE SET OF DRAWINGS ON THE JOB TO BE USED STRICTLY FOR RECORDING ANY INSTALLATION DEVIATIONS FROM THE CONTRACT DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR DAILY CLEAN -UP AND REMOVAL OF FIRE PROTECTION DEBRIS FROM THE SITE WEEKLY. THE PREMISES SHALL BE KEPT IN A NEAT AND ORDERLY CONDITION. CONTRACTOR SHALL REVIEW AND FOLLOW ALL LANDLORD REQUIREMENTS. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES THAT THESE REQUIREMENTS HAVE BEEN REVIEWED AND ARE IN THE BID PRICE AND INFORM LANDLORD IN ADVANCE OF ANY DOWN TIME. 15413 SHOP DRAWINGS A. CONTRACTOR SHALL SUBMIT FOR THE ARCHITECT'S AND LANDLORD REVIEW SIX (6) COMPLETE COPIES OF THE CATALOG DATA AND /OR SHOP DRAWINGS FOR THE LISTED ITEMS OF EQUIPMENT AND ALL COMPONENTS TO BE USED IN THE WORK, INCLUDING SPECIFIC PERFORMANCE DATA, MATERIAL dESCRIPTION, RATING, CAPACITY, WORKING PRESSURE, MATERIAL GAUGE OF THICKNESS, BRAND NAME, CATALOG NUMBER AND GENERAL TYPE. THE SUBMISSION SHALL BE COMPILED BY CONTRACTOR AND REVIEWED BY ENGINEER BEFORE ANY OF THE EQUIPMENT IS ORDERED. 1. SPRINKLERS (AS REQUIRED) 2. VALVES (AS REQUIRED) 3. TAMPER SWITCHES (AS REQUIRED) 4. WATER FLOW SWITCHES (AS REQUIRED) B. HYDRAULIC CALCULATIONS (AS REQUIRED) 6. CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM WHEN SUBMITTED FOR THE ARCHITECT'S REVIEW, SHOP DRAWINGS SHALL BEAR GENERAL CONTRACTOR'S CERTIFICATION THAT THEY HAVE REVIEWED, CHECKED AND APPROVED THE SHOP DRAWINGS, THAT THEY ARE IN HARMONY WITH THE REQUIREMENTS OF THE PROJECT AND WITH THE PROVISIONS OF THE CONTRACT DOCUMENTS AND TWAT THEY HAVE VERIFIED ALL FIELD MEASUREMENTS AND CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBER AND FIELD MEASUREMENTS AND SIMILAR DATA. CONTRACTOR SI-IALL ALSO CERTIFY THAT THE WORK REPRESENTED BY THE SHOP DRAWINGS IS RECOMMENDED BY CONTRACTOR AND THE CONTRACTOR'S GUARANTEE WILL FULLY APPLY. C. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL CONDITIONS THEREIN. ALL PROPOSALS SHALL TAKE INTO CONSIDERATION ALL SUCH CONDITIONS AS THEY MAY AFFECT THE WORK UNDER THIS CONTRACT. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES THAT THIS EXAMINATION OF THE SITE WAS BEEN DONE. 15417 TESTS A. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TESTING OF SPRINKLER PIPING PER NFPA. B. TEST SPRINKLER PIPING WITH A HYDROSTATIC TEST AT 200 PSI FOR 2 HOURS WITH NO VISIBLE LEAKAGE. C. TEST ALARMS, FLOW SWITCHES, AND TAMPERPROOF SWITCHES AND ADJUST AS NECESSARY. D. CONTRACTOR AND LANDLORD SHALL SIGN CERTIFICATES, INDICATING WITNESSING OF ALL TESTS REQUIRED BY NFPA -13 FOR ABOVE GROUND PIPING. E. REPAIR ANY LEAKING JOINTS AND REPAIR ANY DAMAGE TO THE FACILITY THAT THE LEAK MAY HAVE CREATED. CLEAN, PAINT, OR REPLACE ANY DAMAGED COVERINGS AS REQUIRED TO MEET TI-4E LANDLORD'S APPROVAL. NOTIFY THE LANDLORD IN WRITING FOR ANY SCHEDULING OF ANY TESTS OR DOWNTIME OF THE EXISTING SPRINKLER SYSTEM. 15425 SUPPORTS, ANCHORS, AND SEALS A. UL LISTED HANGERS, BEAM CLAMPS, HANGER RODS, PIPE ATTACHMENTS, AND PIPE SLEEVES SHALL BE PER SP -58. EQUAL MANUFACTURERS TO BE GRINNELL, 13-LINE, OR MICHIGAN HANGERS. 5. ALL HANGER ASSEMBLIES SHALL BE UL AND FM APPROVED. C. HANGER SPACING SHALL MEET NFPA -13 MINIMUM REQUIREMENTS. 15426 INTERIOR PIPE TUBE AND FITTINGS AND SPRINKLER HEADS A. SPRINKLER HEADS: 1. ALL SPRINKLER HEADS SHALL BE NEW U.L., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY STAR, RELIABLE, GRINNEL, VIKING, OR CENTRAL SPRINKLER CO. 2. ALL SPRINKLER HEADS SHALL BE RATED FOR 165'F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. 3 "SALES" AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE TO MATCH CEILING. 4. "NON- SALES" AREA SPRINKLER. HEADS ARE TO SE PENDANT TYPE ROUGH BRASS FINISH. 5. "NON- SALES" LAVATORY AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE TO MATCH CEILING. 6. "MALL BULKHEAD" AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE TO MATCH CEILING. B. PIPING: 1. SCHEDULE 40, BLACK STEEL PIPE, ASTM A -53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B- 36 -10 -70 FOR WROUGHT STEEL PIPE. 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. 4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. 5. HANGERS SHALL COMPLY WITH LANDLORD AND CODE REQUIREMENTS. C. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 SQ. FT. IN "STOCK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL SE BASED ON NFPA ORDINARY HAZARD. D. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH OTHER TRADES. F. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. F. PROVIDE AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE LANDLORD, LOCAL INSPECTOR, OR INSURANCE CARRIER. G. CONTRACTOR SI -IALL BE RESPONSIBLE FOR DAMAGE CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE BY THIS CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. PROPERLY COMPLETED AND SIGNED 'SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, AND AUTHORITIES HAVING JURISDICTION. 15430 SPRINKLER PIPING SPECIALTIES A. PROVIDE ALL NECESSARY DRAINS. COORDINATE THE EXACT LOCATION WITH THE ARCHITECT AND LANDLORD PRIOR TO ANY INSTALLATION. PLUMBING, FIRE PROTECTION AND HVAC SPECIFICATIONS 15600 HVAC BASIC MATERIALS AND METHODS A. THIS CONTRACTOR IS TO BECOME INFORMED OF THE EXACT DIMENSIONS OF FINISHED WORK WHERE PIPES, DUCTS AND EQUIPMENT ARE TO BE PLACED AND WILL ARRANGE THE WORK ACCORDINGLY, ASSUMING ALL RESPONSIBILITY FOR PROPER LOCATION AND COORDINATION OF THE WORK. B. IN THE ERECTION OF THE DUCTWORK, SPECIAL CARE SHALL BE USED PROVIDING SUPPORT. C. ALL DUCTWORK SHALL BE PLACED SO AS TO AVOID INTERFERENCES WITH PLUMBING PIPES, ELECTRIC CONDUITS OR PIPES OF OTHER CONTRACTORS. ALL DUCTWORK MUST BE PROVIDED WITH SUFFICIENT DISTANCE FROM WALLS, PIPES, AND OTHER OBSTACLES TO PERMIT THE APPLICATION OF FULL THICKNESS OF INSULATION SPECIFIED. E. THIS CONTRACTOR SHALL PERFORM AN ACCURATE AND COMPLETE BALANCE OF AIR SYSTEMS AS A PART OF THIS CONTRACT, WHICH SHALL BE COMPLETED BEFORE FINAL ACCEPTANCE OF THE WORK OF THIS CONTRACT. AIR BALANCING SHALL BE SUBCONTRACTED TO A CERTIFIED MEMBER OF ASSOCIATED AIR BALANCE COUNCIL. F. VIBRATION ISOLATION DEVICES 1. VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED WITH SUPPORTS BETWEEN VIBRATING EQUIPMENT AND THE STRUCTURE (FANS, AIR HANDLERS, ETC.) BY THIS CONTRACTOR. 2. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 3. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID 'GROUNDING' THE ISOLATOR. 4. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 5. CONSULT MANUFACTURER FOR APPLICATION DATA. 15700 HVAC AIR DISTRIBUTION AND RETURN SYSTEMS A. PROVIDE AND INSTALL DUCTWORK AND PLENUMS OF SIZE AND LOCATION AS SHOWN ON DRAWINGS. ALL DUCTS FOR AIR VELOCITIES LESS THAN 2000 FPM AND STATIC PRESSURE IN DUCT 2" OR. LESS SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL. THE GAUGE OF STEEL USED IN ALL DUCTS SHALL BE AS FOLLOWS: E. F. 1. WHERE GREATER RECTANGULAR DIMENSION IS 12" OR LESS USE 26 GAUGE. 2. WHERE GREATER RECTANGULAR DIMENSION 15 FROM 12" THROUGH 30" USE 24 GAUGE. 3. WHERE GREATER RECTANGULAR DIMENSION 15 FROM 31" THROUGH 54" USE 22 GAUGE. 4. WHERE GREATER RECTANGULAR DIMENSION IS FROM 55" THROUGH 84" USE 20 GAUGE. B. TRANSVERSE JOINTS AND BRACING TO CONFORM TO "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" (CURRENT SMACNA). C. ALL DUCTS SHALL BE RIGID AND SHALL BE CROSS - BROKEN, PROPERLY STIFFENED WITH SUITABLE BRACES, TOES, OR ANGLES TO KEEP THEM TRUE TO SHAPE AND PREVENT BUCKLING. ALL VERTICAL DUCTS SHALL BE OF STRONG ENOUGH CONSTRUCTION TO CARRY 100 LBS. SUSPENDED LOAD FROM HANGERS WITHOUT BUCKLING. SOLDER ALL JOINTS WHERE NECESSARY TO INSURE TIGHT WORK. SEAMS OF ALL DUCTS AND JOINTS SHALL SE HAMMERED TO A SMOOTH SURFACE ON THE INSIDE. CONSTRUCTION INCLUDING HANGERS AND SUPPORTING SYSTEMS OF ALL DUCTWORK SHALL. ALSO BE IN ACCORDANCE WITH "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE' (CURRENT SMACNA). FLEXIBLE CONNECTIONS SHALL BE INSTALLED ON THE OUTLET AND INTAKE OF AIR HANDLING UNITS AND FANS. THESE CONNECTIONS SHALL BE AT LEAST 6" LONG, MADE OF NFPA 90A APPROVED FLAMEPROOF FABRIC. FURNISH AND INSTALL VOLUME CONTROLLER AND EXTRACTOR AT ALL BRANCH TAKEOFFS IN SUPPLY AND RETURN FROM MAIN DUCTS TO ALL BRANCH DUCTS WHERE SHOWN. UNIT SHALL BE OF TWO GAUGES HEAVIER THAN THE DUCT. G. PROVIDE MANUAL ADJUSTING LEVER FOR EACH UNIT. UNITS SHALL MOVE FROM FULL OPEN TO FULLY CLOSED POSITION TO 'PLY AND RETURN REGISTERS, GRILLES AND DIFFUSERS AS SHOWN ON THE DRAWINGS AND SCHEDULE. J. FLEXIBLE SUPPLY AIR DUCTWORK WITH I THICK FIBERGLASS BLANKET INSULATION WITH METALIZED FILM VAPOR BARRIER OUTER JACKET. FLEXIBLE DUCT IN RETURN AIR PLENUM TO BE CLEARLY LABELED "CLASS 1" EVERY FOUR FEET. FLEXIBLE DUCT LENGTH MAY NOT EXCEED FIVE FEET. INSULATION SI-4ALL HAVE MIN. INSTALLED R -VALUE OF 5.0. K. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED. L. DUCT CONSTRUCTION SHALL BE AS FOLLOWS: 1) EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT ALL LOW PRESSURE DUCT IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA STANDARDS WITH THE FOLLOWING PRESSURE CLASSIFICATIONS: A) SUPPLY DUCTS: 2" W.G. POSITIVE. B) RETURN AND EXHAUST DUCTS: 2" N.G. NEGATIVE. 2) SEAL. ALL LOW PRESSURE DUCTS PER SMACNA CLASS E AND ALL MEDIUM PRESSURE DUCTS TO SMACNA CLASS A. 5) REGARDLESS OF ABOVE DUCT CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. M. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCK SEAM CONSTRUCTION FOR ALL SIZES I2" DIAMETER AND LARGER. ROUND DUCTWORK SIZES 10" DIAMETER AND SMALLER MAY BE SNAP- LOCK CONSTRUCTION. ALL SNAP LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL WITH SPOT WELDED AND BONDED CONSTRUCTION. DUCTWORK SHALL BE AS MANUFACTURED BY UNITED MCGILL, SEMCO, OR APPROVED EQUAL. N. ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASS- FIBER FABRIC REINFORCED TAPE. JOINTS ALSO SHALL SE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SURESOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 15792 VARIABLE AIR VOLUME HVAC UNITS A. UNITS SI-IALL BE FACTORY ASSEMBLED PARALLEL FAN POWERED VARIABLE AIR VOLUME BOXES WITH ELECTRIC HEATING, FULLY INSULATED CONSTRUCTION, DDC CONTROLS AND CAPABLE OF THE MAXIMUM CFM INDICATED. B. CABINET SHALL BE GALVANIZED STEEL, BONDERIZED AND COATED WITH BAKED ENAMEL. CABINET SHALL BE LINED WITH I" THICK NEOPRENE - COATED FIBERGLASS WITH EASILY REMOVABLE SERVICE PANELS TO ALL OPERATING COMPONENTS. C. CONTROLS: 1) INSTALL HEATING /COOLING "S" SENSORS WITH TEMPERATURE ADJUSTMENT TO PROVIDE CONTROL OF AIR VALVE AND STAGED HEATING WITH LOCKING CLEAR PLASTIC COVER. MOUNT THE BOTTOM OF THE SENSOR 48" ABOVE THE FLOOR PER ADA. SENSORS SUPPLIED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE. 2) WHEN SENSOR CALLS FOR COOLING, AIR VALVE SHALL OPEN IN 5% INCREMENTS UNTIL FULLY OPEN, OR UNTIL SPACE TEMPERATURE IS SATISFIED. 3) WHEN SENSOR CALLS FOR HEATING, AIR VALVE SHALL CLOSE IN 5% INCREMENTS UNTIL 25% OPEN, THEN FAN SHALL ENERGIZE AND EACH STAGE OF HEATING SHALL BE ENERGIZED AS REQUIRED UNTIL SPACE TEMPERATURE IS SATISFIED. 4) HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL ELEMENTS ARE CALIBRATED, ADJUSTED, AND IN PROPER WORKING CONDITION. 5) CONTROLS SI -IALL MEET ALL LANDLORD REQUIREMENTS. FIELD VERIFY AND COORDINATE ALL REQUIREMENTS IN FIELD WITH LANDLORD PRIOR TO BID AND INCLUDE THE COST OF TIE -IN TO LANDLORD'S SYSTEMS IN SID. ANY MISCELLANEOUS MATERIALS OR LABOR REQUIRED FOR TIE -IN OR TO MAKE FURNISHED CONTROLS COMPATABLE WITH LANDLORD SYSTEM SHALL BE BY A LANDLORD APPROVED CONTRACTOR AND SHALL SE AT THE SOLE COST OF THE GENERAL CONTRACTOR. D. PROVIDE NEW VIBRATION ISOLATION HANGERS AND SUPPORTS AS REQUIRED TO SUPPORT UNIT PER LANDLORD'S REQUIREMENTS AND MANUFACTURER'S RECOMMENDATIONS. FIELD VERIFY AND COORDINATE ALL REQUIREMENTS. E. GENERAL CONTRACTOR SHALL HANG UNIT FROM STRUCTURE AND MAKE POWER CONNECTIONS TO UNITS. F. GENERAL CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL CONTROLS, CONTROL WIRING AND TO MAKE OPERATIONAL. G. VAV UNITS SHALL BE TRANE AS FURNISHED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE AND INSTALLED SY THIS CONTRACTOR. UPON DELIVERY OF UNITS, CONTRACTOR SHALL VERIFY ALL EQUIPMENT IS AS SPECIFIED ON DRAWINGS INCLUDING ALL ELECTRICAL REQUIREMENTS, ACCESSORIES AND OTHER REQUIREMENTS. ANY DESCREPFNCIES MUST BE REPORTED TO DELIA'S CONSTRUCTION MANAGER WITHIN THE FIRST TWENTY -FOUR (24) HOURS AFTER DELIVERY. IT 15 THIS CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL REQUIREMENTS FOR VAVS, CONTROLS, MEDIUM PRESSURE DUCT, AND ALL OTHER REQUIREMENTS WITH LANDLORD IN FIELD PRIOR TO BID AND INCLUDE THE COST OF TH19 WORK IN THE BID. 15905 AIR DISTRIBUTION DEVICES A. SQUARE CEILING SUPPLY AIR DIFFUSER - STEEL SQUARE CEILING DIFFUSER, REMOVEASLE PLAQUE FACE PANEL, ROUND NECK, VOLUME CONTROL DAMPER PRICE MODEL #BPD. B. SQUARE CEILING RETURN AIR REGISTER - STEEL SQUARE CEILING DIFFUSER, REMOVEABLE PLAQUE FACE PANEL, ROUND NECK, VOLUME CONTROL DAMPER, PRICE MODEL #SPD. C. FINISHES - FURNISH ALL AIR DISTRIBUTION DEVICES WITH PRIME COATED AND WHITE BAKED ENAMEL FINISH COAT UNLESS SPECIFIED OTHERWISE. D. COORDINATE AIR DISTRIBUTION DEVICE LOCATIONS WITH ALL AFFECTED CONTRACTORS BEFORE INSTALLING DUCTWORK. SIGNIFICANT DEVIATIONS IN LOCATIONS FROM THOSE SHOWN ON THE DRAWINGS MUST BE APPROVED BY ARCHITECT BEFORE INSTALLATION. E. SUSPEND CEILING AIR DEVICES FROM STRUCTURE ON WIRE HANGERS OR FROM RIGI_ 15915 DAMPERS =VICES SHALL BE PRICE AS FURNISHED BY DELIA'S. A. RECTANGULAR DUCT GALVANIZED STEEL MANUAL BALANCE AND MOTORIZED DAMPER 6" WIDE 16 GAUGE OPPOSED BLADES, CHANNEL FRAME WITH BRACED CORNERS, CONCEALED LINKAGE, TEFLON FILLED BEARINGS, 3 /B" DIAMETER AXLE, 6" LONG CONTROL SHAFT. MOTORIZED DAMPER TO HAVE REPLACEABLE BUTYL RUBBER SEALS INSTALLED ALONG THE TOP, BOTTOM AND SIDES OF THE FRAME, AS WELL AS, ALONG ALL SIDES OF EACH BLADE. B. ROUND GALVANIZED STEEL MANUAL BALANCE DAMPER WITH SINGLE 16 GAUGE BLADE, CHANNEL FRAME, STAINLESS STEEL SLEEVE BEARINGS PRESSED INTO FRAME, 3/8" DIAMETER AXLE EXTENDED 6" FOR CONTROL SHAFT, BLADE STOP. C. EQUIP DAMPERS WITH LOCKING QUADRANTS. D. CHECK DAMPERS FOR PROPER OPERATION BEFORE AND AFTER INSTALLATION. E. INSTALL BALANCE DAMPERS WHERE SHOWN ON THE DRAWINGS AND ELSEWHERE AS NECESSARY TO OBTAIN PROPER SYSTEM BALANCE. F. DAMPERS SHALL BE RUSKIN. EQUAL PRODUCT BY AMERICAN WARMING AND VENTILATING, LOUVERS AND DAMPERS, OR PREFCO MAY BE FURNISHED AT THE CONTRACTOR'$ OPTION. G. 15939 CEILING EXHAUST FANS A. CEILING EXHAUST FANS BASED ON GROAN SHALL BE OF TI-4E CENTRIFUGAL DIRECT DRIVE TYPE. THE FAN HOUSING SHALL SE CONSTRUCTED OF HEAVY GAUGE GALVANIZED STEEL. THE HOUSING INTERIOR SHALL BE LINED WITH 1/2" ACOUSTICAL INSULATION. THE OUTLET DUCT COLLAR SHALL INCLUDE AN ALUMINUM BACKDRAFT DAMPER AND SHALL BE ADAPTABLE FOR HORIZONTAL DISCHARGE. B. THE ACCESS FOR WIRING SHALL BE EXTERNAL. THE MOTOR DISCONNECT SHALL BE INTERNAL AND OF THE PLUG TYPE. C. THE MOTOR SHALL BE MOUNTED ON VIBRATION ISOLATORS. THE FAN WHEEL- SHALL BE OF THE FORWARD CURVED CENTRIFUGAL TYPE AND DYNAMICALLY SALANCED. D. ALL FANS SHALL BEAR THE AMCA CERTIFIED RATINGS SEAL FOR SOUND AND AIR PERFORMANCE AND SHALL BE U.L. LISTED AND C.S.A. APPROVED. CAPACITIES AS SHOWN ON THE DRAWINGS. E. WIRING BY THE ELECTRICAL CONTRACTOR. F. FANS SHALL BE GROAN AS FURNISHED BY DELIA'S NATIONAL ACCOUNTS REPRESENTATIVE. 15975 INSULATION A. DUCT INSULATION AND APPURTENANCES SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING TWENTY -FIVE (25) AND A SMOKE DEVELOPED RATING NOT EXCEEDING FIFTY (50). B. RECTANGULAR DUCTWORK CONCEALED FROM VIEW SHALL HAVE I" TI -41CK FIBERGLASS DUCT LINER LAMINATED AND PINNED TO DUCT WITH 1.0 PCF DENSITY AND R -VALUE OF 3.7 MIN. OWENS- CORNING COMMERCIAL GRADE FIBERGLASS DUCT LINER. C. ROUND DUCTWORK CONCEALED FROM VIEW 9I -4ALL. HAVE FLEXIBLE FIBERGLASS DUCT WRAP LAMINATED TO FOIL REINFORCED KRAFT VAPOR BARRIER FACING WITH 2" STAPLING FLANGE AND MIN. INSTALLED R -VALUE OF 3.7. OWNS- CORNING COMMERCIAL GRADE FIBERGLASS DUCT WRAP TYPE 100. D. EXPOSED ROUND AND RECTANGULAR DUCTWORK SHALL HAVE NO INSULATION. E. ALL DUCTWORK IN UNCONDITIONED SPACES SHALL HAVE INSULATION DUCT WRAP WITH 4 A MINIMUM INSTALLED R -VALUE OF 5.0. F. INSULATION SHALL NOT BE APPLIED UNTIL TI-4E GENERAL CONSTRUCTION HAS PROGRESSED SUFFICIENTLY TO INSURE AGAINST PHYSICAL OR MOISTURE DAMAGE TO THE INSULATION. ALL INSULATION DAMAGED THROUGH FAILURE TO OBSERVE THIS DIRECTIVE SHALL BE REPLACED AT HVAC CONTRACTOR'S EXPENSE. G. HANGER RODS MUST SE PERPENDICULAR. TO DUCTWORK BEFORE INSULATION IS INSTALLED. H. INSTALL ALL INSULATION ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. I. INSULATION SHALL BE APPLIED OVER FLANGES, JOINTS AND SEAMS IN PIPING AND DUCTWORK. ALL JOINTS AND SEAMS IN INSULATION SHALL BE PROPERLY SEALED TO MAINTAIN VAPOR BARRIER INTEGRITY. K. INSULATION SHALL BE OWENS- CORNING. EQUAL PRODUCT BY ARMSTRONG, CERTAINTEED, SC}- 4ULLER OR KNAUF MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 15980 BALANCING A. ALL AIR DISTRIBUTION SYSTEMS AND WATER SYSTEMS ARE TO BE BALANCED IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING STANDARDS BY AN INDEPENDENT THIRD PARTY CONTRACTOR CERTIFIED BY THE ASSOCIATED AIR BALANCE COUNCIL (AABC). DUCTED AIR RATES ARE TO BE MEASURED AND ADJUSTED TO DELIVER FINAL FLOW RATES WITHIN 10% OF DESIGN RATES. B. AFTER CORRECTING BALANCE OF ALL AIR AND WATER SYSTEMS TO WITHIN 10% OF DESIGNED VALUES, SUBMIT FINAL AIR AND WATER BALANCE REPORTS TO ARCHITECT, ENGINEER AND DELIA'S. C. VERIFY CONTROLS DURING BALANCING, INCLUDING HUMIDITY CONTROLS WHERE APPLICABLE. REVIEWED FOR 1 CODE COMPLIANCE APPROVED JAN - 2 2008 City Of Tukwila I - _SING DIVISION RECEIVED CITY OF TUKWILA DEC 1 8 2007 pBHIvMIT CtN 1 ER *ol m 0 z 0 6 z M4.1 THE ENGINEER ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE USE OF THESE PLANS FOR ANY PROJECT OTHER THAN SPECIFICALLY AUTHORIZED BY THEM AND SIGNED AND SEALED FOR SUCH SPECIFIC LOCATION IN THE STATE SHOWN ON THE SEAL, THIS BUILDING USE IS ONLY APPLICABLE IN AREAS MEETING THE STATED DESIGN CRfrERIA. w a SAS # 07418 DRAWING NUMBER: